Loading...
HomeMy WebLinkAbout20191303 Ver 1_Bradford Drawdown Split_20191108 Draw Down Calculations Stage Storage Calculations Bradford Circle Permeable Pavement Reservoir 1 Water Quality Volume(Ft3) 154.2 Total WQv Required Elev. (Ft) Area (sf) Volume(cf) Top Elevation of Temp Pool (Ft) 337.15 Overflow Elevation 336.82 1230 Orifice Invert Elevation (Ft) 334.97 405.9 Maximum Head (Ft) 2.16 At Centroid of Orifice 337.15 1230 Driving Head Ho(Ft) 1.08 1/2 Maximum Head Orifice Diameter(in) 0.50 Note-Reservoir Elevations Vary Orifice Diameter(Ft) 0.04 Orifice Area (Ft2) 0.001 Orifice Coefficient 0.59 WQv 405.9 Orifice Discharge Q(Ft3/s) 0.01 %Voids 0.38 Days to Complete Drawdown 0.27 Between 2 and 5 Days Total WQv Provided(cf) 154.242 Q=CDAV2SH, Where: Q = Discharge(cfs) CD = Coefficient of discharge(dimensionless)-see Table 3-8 A = Cross-sectional area of flow at the orifice entrance(sq ft) g = Acceleration of gravity(32.2 ft/sec2) Ho = Driving head(ft),measured from the centroid of the orifice area to the water surface-Note:Usually use Ho/3 to compute drawdown through an orifice to reflect the fact that head is decreasing as the drawdown occurs. Figure 3-3 Schematic section through an orifice Ho (me � A=.7cR2 R, Table 3-8 Values of Coefficient of Discharge,CD(Malcom,1989) Enhance Condition CD Typical default value 0.60 Square-edged entrance 0.59 Concrete pipe,grooved end 0.65 Corrugated metal pipe,mitred to slope 0.52 Corrugated metal pipe,projecting from fill 1.00 Draw Down Calculations Stage Storage Calculations Bradford Circle Permeable Pavement Reservoir 2 Water Quality Volume(Ft3) 206.9 Total WQv Required Elev. (Ft) Area (sf) Volume(cf) Top Elevation of Temp Pool (Ft) 336.64 Overflow Elevation 336.31 1650 Orifice Invert Elevation (Ft) 334.47 544.5 Maximum Head (Ft) 2.15 At Centroid of Orifice 336.64 1650 Driving Head Ho(Ft) 1.07 1/2 Maximum Head Orifice Diameter(in) 0.50 Note-Reservoir Elevations Vary Orifice Diameter(Ft) 0.04 Orifice Area (Ft2) 0.001 Orifice Coefficient 0.59 WQv 544.5 Orifice Discharge Q(Ft3/s) 0.01 %Voids 0.38 Days to Complete Drawdown 0.36 Between 2 and 5 Days Total WQv Provided(cf) 206.91 Q=CDAJ2gH, Where: Q = Discharge(cfs) CD = Coefficient of discharge(dimensionless)-see Table 3-8 A = Cross-sectional area of flow at the orifice entrance(sq ft) g = Acceleration of gravity(32.2 ft/sec2) Ho = Driving head(ft),measured from the centroid of the orifice area to the water surface-Note:Usually use Ho/3 to compute drawdown through an orifice to reflect the fact that head is decreasing as the drawdown occurs. Figure 3-3 Schematic section through an orifice 1;) time . Q A=.7cR2 R, Table 3-8 Values of Coefficient of Discharge,CD(Malcom,1989) Enhance Condition CD Typical default value 0.60 Square-edged entrance 0.59 Concrete pipe,grooved end 0.65 Corrugated metal pipe,mitred to slope 0.52 Corrugated metal pipe,projecting from fill 1.00 Draw Down Calculations Stage Storage Calculations Bradford Circle Permeable Pavement Reservoir 3 Water Quality Volume(Ft3) 140.4 Total WQv Required Elev. (Ft) Area (sf) Volume(cf) Top Elevation of Temp Pool (Ft) 336.13 Overflow Elevation 335.8 1120 Orifice Invert Elevation (Ft) 333.97 369.6 Maximum Head (Ft) 2.14 At Centroid of Orifice 336.13 1120 Driving Head Ho(Ft) 1.07 1/2 Maximum Head Orifice Diameter(in) 0.50 Note-Reservoir Elevations Vary Orifice Diameter(Ft) 0.04 Orifice Area (Ft2) 0.001 Orifice Coefficient 0.59 WQv 369.6 Orifice Discharge Q(Ft3/s) 0.01 %Voids 0.38 Days to Complete Drawdown 0.24 Between 2 and 5 Days Total WQv Provided(cf) 140.448 Q=CDAV2SH, Where: Q = Discharge(cfs) CD = Coefficient of discharge(dimensionless)-see Table 3-8 A = Cross-sectional area of flow at the orifice entrance(sq ft) g = Acceleration of gravity(32.2 ft/sec2) Ho = Driving head(ft),measured from the centroid of the orifice area to the water surface-Note:Usually use Ho/3 to compute drawdown through an orifice to reflect the fact that head is decreasing as the drawdown occurs. Figure 3-3 Schematic section through an orifice Ho (me � A=.7cR2 R, Table 3-8 Values of Coefficient of Discharge,CD(Malcom,1989) Enhance Condition CD Typical default value 0.60 Square-edged entrance 0.59 Concrete pipe,grooved end 0.65 Corrugated metal pipe,mitred to slope 0.52 Corrugated metal pipe,projecting from fill 1.00