HomeMy WebLinkAboutNCG200469_Inspection Report_20191108ROY COOPER
Governor
MICHAEL S. REGAN
Secretary
S. DANIEL SMITH
Director
Tri-State Scrap Metal, Inc.
Attn: John Gribble
79 Pond Road
Asheville, North Carolina 28806
NORTH CAROLINA
Environmental Quality
November 8, 2019
Subject: Compliance Evaluation Inspection
Permit: NCG200000
Certificate of Coverage: NCG200469
Buncombe County, North Carolina
Dear Mr. Gribble:
Enclosed please find a copy of the Compliance Evaluation Inspection Report for the
inspection I conducted at the subject facility on November 5, 2019.
The report should be self-explanatory; however, should you have any questions
concerning this report, please do not hesitate to contact me at (828) 296-4500 or by email
at Isaiah.reed@ncdenr.gov.
Since
Isaiah Reed, WQ, CEPSCI, MS4CECI
Environmental Specialist
Land Quality Section
Enclosure: Inspection Report
D_EQ5� North Carolina Department of Environmental Quality I Division of Energy, Mineral and Land Resources
Asheville Regional Office 12090 U.S. Highway 70 1 Swannanua, North Carolina 28778
Noamcuwuw.
wo828.296.4500
Permit: NCG200469
SOC:
County: Buncombe
Region: Asheville
Contact Person: John Gribble
Directions to Facility:
System Classifications:
Primary ORC:
Secondary ORC(s):
On -Site Representative(s):
Related Permits:
Compliance Inspection Report
Effective: 08/01/19 Expiration: 05/31/24 Owner: Tri-State Scrap Metal Inc
Effective: Expiration: Facility: Tri-State Scrap Metal, Inc.
79 Pond Rd
Inspection Date: 11/05/2019
Primary Inspector: Isaiah L Reed
Secondary Inspector(s):
Title:
Entry Time: 11:30AM
Certification:
Asheville NC 28806
Phone: 828-670-9006
Phone:
Exit Time: 12:30PM
Phone: 828-296-4614
Reason for Inspection: Routine Inspection Type: Compliance Evaluation
Permit Inspection Type: Wholesale Trade of Metal Waste and Scrap Stormwater Discharge CDC
Facility Status: Compliant Not Compliant
Question Areas:
Storm Water
(See attachment summary)
Page 1 of 3
permit: NCG200469 Owner -Facility: Tri-State Scrap Metal Inc
Inspection Date: 11/05/2019 Inspection Type : Compliance Evaluation Reason for Visit: Routine
Inspection Summary:
On November 5, 2019 this facility was inspected for complaince and to determine what progress had been made relating to
the previousely issued NOV. I met with John Gribble on site. No issues were noted with the Stormwater Pollution Prevention
Plan during the inspection. However, a practical means of inspecting the facility and determining the effectiveness of the
BMPs on site has not been established. The permittee is directed to submit a written plan of action concerning how the
process at the facility will be modified to allow for facility inspections.
If you have any questions, please contact this office at (828) 296-4614.
Page 2 of 3
Permit: NGG200469 Owner -Facility: Tri-State Scrap Metal Inc
Inspection Date: 11/05/2019 Inspection Type : Compliance Evaluation Reason for Visit: Routine
Stormwater Pollution Prevention Plan
Does the site have a Stormwater Pollution Prevention Plan?
# Does the Plan include a General Location (USGS) map?
# Does the Plan include a "Narrative Description of Practices"?
# Does the Plan include a detailed site map including outfall locations and drainage areas?
# Does the Plan include a list of significant spills occurring during the past 3 years?
# Has the facility evaluated feasible alternatives to current practices?
# Does the facility provide all necessary secondary containment?
# Does the Plan include a BMP summary?
# Does the Plan include a Spill Prevention and Response Plan (SPRP)?
# Does the Plan include a Preventative Maintenance and Good Housekeeping Plan?
# Does the facility provide and document Employee Training?
# Does the Plan include a list of Responsible Party(s)?
# Is the Plan reviewed and updated annually?
# Does the Plan include a Stormwater Facility Inspection Program?
Has the Stormwater Pollution Prevention Plan been implemented?
Comment: See summary for more information
Permit and Oulfalls
# Is a copy of the Permit and the Certificate of Coverage available at the site?
# Were all outfalls observed during the inspection?
# If the facility has representative outfall status, is it properly documented by the Division?
# Has the facility evaluated all illicit (non stormwater) discharges?
Comment:
Yes No NA NE
■❑❑❑
■❑❑❑
N ❑ ❑ ❑
■❑❑❑
■❑❑❑
❑ ❑ ❑
E ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
■❑❑❑
❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
❑■❑❑
❑■❑❑
Yes No NA NE
■❑❑❑
■❑❑❑
❑❑■❑
■❑❑❑
Page 3 of 3