Loading...
HomeMy WebLinkAboutNCG110111_Inspection Report_20191108ROY COOPER Governor MICHAEL S. REGAN secretary S. DANIEL SMITH Director NORTH CAROLINA Environmental Quality November 8, 2019 Tuckaseigee Water and Sewer Authority Attention: Stan Bryson 1246 West Main Street Sylva, North Carolina 28779 Subject: Compliance Evaluation Inspection Permit: NCG110000 Certificate of Coverage: NCG110111 Jackson County, North Carolina Dear Mr. Stan Bryson: Enclosed please find a copy of the Compliance Evaluation Inspection Report for the inspection I conducted at the subject facility on November 6, 2019. The report should be self-explanatory; however, should you have any questions concerning this report, please do not hesitate to contact me at (828) 296-4500 or by email at Isaiah.reed@ncdenr.gov. Sincer Isaiah Reed, CP Q, CEPSCI, S4CECI Environmental Specialist Land Quality Section Enclosure: Inspection Report D E Q'� North Carolina Department of Environmental Quality I Division of Energy, Mineral and Land Resources Asheville Regional Office 12090 U.S. Highway 70 I Swannanoa, North Carolina 28778 rvow,nc�+anw 828.296.4500 Permit: NCG110111 SOC: County: Jackson Region: Asheville Contact Person: Joe Cline Compliance Inspection Report Effective: 06/01/18 Expiration: 05/31/23 Owner: Tuckaseigee Water and Sewer Authority Effective: Expiration: Facility: Jackson County WWTP 1871 N River Rd Title: Sylva NC 28779 Phone: 828-586-5189 Directions to Facility: Hwy 40 W to Hwy. 74 W to Dillsboro. Hwy. 23 South to River Road. Facility is located at 1871 N River Rd System Classifications: Primary ORC: Certification: Phone: Secondary ORC(s): On -Site Representative(s): Related Permits: Inspection Date: 11/06/2019 EntryTime: 02:30PM Exit Time: 03:30PM Primary Inspector: Isaiah L Reed Phone: 828-296-4614 Secondary Inspector(s): Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: Municipal W NTP > 1 MGD, Stormwater Discharge, CDC Facility Status: ❑ Compliant 0 Not Compliant Question Areas: Storm Water (See attachment summary) Page 1 of 3 Permit: NOG110111 Owner - Facility: Tuckaseigee Water and Sewer Authority Inspection Date: 11/06/2019 Inspection Type : Compliance Evaluation Reason for Visit: Routine Inspection Summary: On November 6, 2019 this facility was inspected for compliance. I met with Stan Bryson on site. Due to confusion as to the nature of the permitting situation at the facility, permit responsibilities have been overlooked. I discussed the permitting responsibilities with Mr. Bryson, and will be conducting a re -inspection on or after January 9, 2019. he re -inspection will be to confirm that a SWPPP has been created and that all permitting requirements have been implemented. If you have any questions, please contact this office at (828) 296-4614 Page 2 of 3 Permit: NCG110111 Owner -Facility: Tuckaseigee Water and Sewer Authority Inspection Date: 11/06/2019 Inspection Type : Compliance Evaluation Reason for Visit: Routine Stormwater Pollution Prevention Plan Yes No NA NE Does the site have a Stormwater Pollution Prevention Plan? ❑ 0 ❑ ❑ # Does the Plan include a General Location (USGS) map? ❑ ❑ ❑ # Does the Plan include a "Narrative Description of Practices'? ❑ ❑ ❑ # Does the Plan include a detailed site map including outfall locations and drainage areas? ❑ 0 ❑ ❑ # Does the Plan include a list of significant spills occurring during the past 3 years? ❑ 0 ❑ ❑ # Has the facility evaluated feasible alternatives to current practices? ❑ 0 ❑ ❑ # Does the facility provide all necessary secondary containment? ❑ ❑ ❑ # Does the Plan include a BMP summary? ❑ ❑ ❑ # Does the Plan include a Spill Prevention and Response Plan (SPRP)? ❑ ❑ ❑ # Does the Plan include a Preventative Maintenance and Good Housekeeping Plan? ❑ 0 ❑ ❑ # Does the facility provide and document Employee Training? ❑ 0 ❑ ❑ # Does the Plan include a list of Responsible Party(s)? ❑ 0 ❑ ❑ # Is the Plan reviewed and updated annually? ❑ ❑ ❑ # Does the Plan include a Stormwater Facility Inspection Program? ❑ ❑ ❑ Has the Stormwater Pollution Prevention Plan been implemented? ❑ ❑ ❑ Comment: See summary for more information Qualitative Monitoring Yes No NA NE Has the facility conducted its Qualitative Monitoring semi-annually? ❑ 0 ❑ ❑ Comment: See summary for more information. Permit and Outfalls Yes No NA NE # Is a copy of the Permit and the Certificate of Coverage available at the site? 0 ❑ ❑ ❑ # Were all oulfalls observed during the inspection? 0 ❑ ❑ ❑ # If the facility has representative outfall status, is it properly documented by the Division? ❑ ❑ ❑ # Has the facility evaluated all illicit (non stormwater) discharges? ❑ ❑ ❑ Comment Page 3 of 3