Loading...
HomeMy WebLinkAboutNC0026441_Analytical Report 0819-709_20191031 Siler City WWTP 198 Utility Drive Siler City, NC 27344 RECEIVED OCT 31 2019 NCDEQ/DWR/NPDES NC0026441 Siler City, NC Samples Received: 08/06/2019 Analytical Report 0819-709 Isotope Dilution Method PFAS — DEQ List Enthalpy Analytical, LLC — Ultratrace Lindsay Boone O. (910)212-5855/ F. 910-212-5866 i..IA LPY Iboone(c enthalpy.corn/www.enthalpy.corn 2714 Exchange Drive, Wilmington, NC 28405 I certify that to the best of my knowledge all analytical data presented in this report: • Have been checked for completeness • Are accurate, error-free, and legible • Have been conducted in accordance with approved protocol, and that all deviations and analytical problems are summarized in the appropriate narrative(s) This analytical report was prepared in Portable Document Format (.PDF) and contains 25 pages. Associate II iew Performed by: Juanica L. Thomas 09-10-19 Report Issued Date: EN.,1.,.F- A I.V' Et EU#0819-709 2 of 25 Summary of Results • EN 1 11 ALP EU#08 9 709 3 of 25 TH.ALPY L .._. A N L Y T I c A I., Summary of Results: PFAS Enthalpy Ultratrace Batch # 10443 PFAS Analyte Method Blank Effluent ng/L ng/L Acids PFBA NDU NDU PFPeA NDU 13.0 PFHxA NDU 5.89 J PFHpA NDU 0.7171 PFOA ND U 4.02 J PFNA NDU ND U PFDA NDU ND U PFUnA NDU ND U PFDoA NDU ND U PFTrA NDU ND U PFTA NDU ND U Sulfonates L-PFBS NDU ND U PFPeS NDU ND U PFHxS NDU ND U PFHpS NDU ND U PFOS NDU 3.84J PFNS NDU ND U PFDS NDU ND U Other PFOSA NDU NDU N-MeFOSAA ND U ND U N-EtFOSAA ND U ND U Lab Sample ID MB_10443 0819-709_10443_001 EU#0819-709 4 of 25 Detailed Results A, EN EU#0819-709 5 of 25 EH ' ` _. ANAIYIICAI Effluent Detailed Results-PFAS Client Details Client Sample ID: Effluent Client Name: Siler City Client Project ID: N/A Sample Collection Date: 06-Aug-19 Lab/Sample Details Lab Job 6: 0819-709 Matrix: Aqueous Date Received: 06-Aug-19. Lab Sample ID: 0819-709_10443_001 Wt./Vol. 35.7 Date Extracted: 03-Sep-19 QC Batch St: 10443 Date Analyzed: 04-Sep-19 Final Volume(ml) 0.4 Time Analyzed: 11:55:19 Analyte CAS Number Conc.(ng/L) MDL(ng/L) RL(ng/L) Qualifiers Standard ES Recoveries(%) Qualifiers Acids MPFBA _ 89.9 PFBA 375-22-4 ND 1.10 10.1 U M5PFPeA 124 PFPeA 2706-90-3 13.0 0.630 10.1 M3PFBS 121 PFHxA 307-24-4 5.89 1.11 10.1 J M5PFHxA 92.3 PFHpA 375-85-9 0.717 0.487 10.1 J M4PFHpA 96.2 PFOA 335-67-1 4.02 0.557 10.1 1 M3PFHxS 95.5 PFNA 375-95-1 ND 0.357 10.1 U M8PFOA 92.8 PFDA 335-76-2 ND 0.877 10.1 U M9PFNA 81.2 PFUnA 2058-94-8 ND 0.337 10.1 U M8PFOS 83.3 PFDoDA 307-55-1 ND 0.333 10.1 U MBFOSA 82.4 PFTrDA 72629-94-8 ND 0.522 10.1 U M6PFDA 87.3 PFTeDA 376-06-7 ND 0.582 10.1 U d3-N-MeFOSAA 71.3 d5-N-EtFOSAA 89.4 Sulfonates M7PFUdA 82.0 L-PFBS 375-73-5 ND 0.582 10.1 U MPFDoA 61.2 PFPeS 2706-91-4 ND 0.694 10.1 U M2PFTeDA 45.0 Q PFHxS 355-46-4 ND 0.580 10.1 U PFHpS 375-92-8 ND 0.546 10.1 U PFOS 1763-23-1 3.84 0.330 10.1 1 PFNS 68259-12-1 ND 0.459 10.1 U PFDS 335-77-3 ND 0.947 10.1 U Other PFOSA 754-91-6 ND 2.56 10.1 U N-MeFOSAA 2355-31-9 ND 0.381 10.1 U N-EtFOSAA 2991-50-6 ND 0.457 10.1 U EU#0819-709 6 of 25 QC Data 9 7 of 25 EU- 0819-7° LN:11 Continuing Calibration PFAS Concentration(ng/L) 901 Standard ID AH36 I Acquisition Date 03-Sep-19 Acquisition Time 20:41:47 Analyte Concentration(ng/L) PD(v. ICAL) Limit Acceptable Acids PFBA 879.2447 -2.4 ±30 Yes PFPeA 871.9578 -3.2 ±30 Yes PFHxA 845.7906 -6.1 ±30 Yes PFHpA 887.7590 -1.5 ±30 Yes PFOA 916.8137 1.8 ±30 Yes PFNA 847.2186 -6.0 ±30 Yes PFDA 895.7780 -0.6 ±30 Yes PFUnA 859.5914 -4.6 ±30 Yes PFDoDA 865.4775 -3.9 ±30 Yes PFTrDA 927.5120 2.9 ±30 Yes PFTeDA 889.1667 -1.3 ±30 Yes Sulfonates L-PFBS 870.0566 9.1 ±30 Yes PFPeS 706.7216 -16.6 ±30 Yes PFHxS 796.2560 -3.1 ±30 Yes PFHpS 836.1744 -2.3 ±30 Yes PFOS 781.8819 -6.2 ±30 Yes PFNS 761.0230 -12.0 ±30 Yes PFDS 778.8848 -10.4 ±30 Yes Other PFOSA 871.3513 -3.3 ±30 Yes N-MeFOSAA 806.9535 -10.4 ±30 Yes N-EtFOSAA -1.0 892.3253 ±30 Yes I EU#0819-709 8 of 25 • Continuing Calibration PFAS Concentration(ng/L) 5000 Standard ID AH36 Acquisition Date 03-Sep-19 Acquisition Time 20:41:47 Analyte Concentration(ng/g) Recovery(%) Limit(%) Acceptable MPFBA 5060 101 ±50 Yes M5PFPeA 5447 109 ±50 Yes M3PFBS 5067 101 ±50 Yes M5PFHxA 5090 102 ±50 Yes M4PFHpA 5278 106 ±50 Yes M3PFHxS 5030 101 ±50 Yes M8PFOA 5151 103 ±50 Yes M9PFNA 5249 105 ±50 Yes M8PFOS 4977 99.5 ±50 Yes M8FOSA 5399 108 ±50 Yes M6PFDA 5000 100 ±50 Yes d3-N-MeFOSAA 4377 87.5 ±50 Yes d5-N-EtFOSAA 5796 116 ±50 Yes M7PFUdA 5268 105 ±50 Yes MPFDoA 4188 83.8 ±50 Yes M2PFTeDA 3684 73.7 ±50 Yes Injection Standards Area Recovery(%) MPFBA 45300 118 M2PFOA 65300 123 MPFDA 47800 130 MPFOS 22300 119 EU#0819-709 9 of 25 Continuing Calibration PFAS Concentration(ng/L) 11510 Standard ID AH33 Acquisition Date 04-Sep-19 Acquisition Time 16:04:30 Analyte Concentration(ng/L) PD(v. ICAL) Limit Acceptable Acids PFBA 12094.7030 5.1 ±30 Yes PFPeA 11632.8702 1.1 ±30 Yes PFHxA 12007.7619 4.3 ±30 Yes P F H pA 11543.2492 0.3 ±30 Yes PFOA 11569.4568 0.5 ±30 Yes PFNA 12052.6473 4.7 ±30 Yes PFDA 11238.3074 -2.4 ±30 Yes PFUnA 11607.6957 0.8 ±30 Yes PFDoDA 12204.4147 6.0 ±30 Yes PFTrDA 11119.4448 -3.4 ±30 Yes PFTeDA 11383.6270 -1.1 ±30 Yes Sulfonates L-PFBS 9831.2803 -3.5 ±30 Yes PFPeS 11414.1568 5.5 ±30 Yes 1 PFHxS 10648.9753 1.4 ±30 Yes PFHpS 10634.6186 -2.7 ±30 Yes PFOS 10224.8768 -4.0 ±30 Yes PFNS 11040.1072 -0.1 ±30 Yes P F DS 10437.6063 -6.0 ±30 Yes Other PFOSA 11705.0452 1.7 ±30 Yes 1 N-MeFOSAA 12629.4752 9.7 ±30 Yes N-EtFOSAA 11875.5281 3.2 ±30 Yes EU#0819-709 10 of 25 Continuing Calibration PFAS Concentration(ng/L) 5000 Acquisition Date 04-Sep-19 Acquisition Time 16:04:30 Analyte Concentration(ng/g) Recovery(%) Limit(%) Acceptable MPFBA 5044 101 ±50 Yes M5PFPeA 5458 109 ±50 Yes M3PFBS 4979 99.6 ±50 Yes M5PFHxA 5096 102 ±50 Yes M4PFHpA 5240 105 ±50 Yes M3PFHxS 5036 101 ±50 Yes M8PFOA 5188 104 ±50 Yes M9PFNA 4936 98.7 ±50 Yes M8PFOS 5018 100 ±50 Yes M8FOSA 5219 104 ±50 Yes M6PFDA 5277 106 ±50 Yes d3-N-MeFOSAA 4694 93.9 ±50 Yes d5-N-EtFOSAA 5146 103 ±50 Yes M7PFUdA 5355 107 ±50 Yes MPFDoA 4813 96.3 ±50 Yes M2PFTeDA 4495 89.9 ±50 Yes Injection Standards Area Recovery(%) MPFBA 45600 118 M2PFOA 62100 117 MPFDA 42100 114 MPFOS 21900 117 EU#0819-709 11 of 25 OPR Evaluation Batch ID#: 10443 Analyte Conc. (ng/g) Recovery(%) Lower Limit Upper Limit Acceptable? Acids PFBA 384 89.6% 73 129 Y PFPeA 411 95.8% 72 129 Y PFHxA 434 101% 72 129 Y PFHpA 418 97.6% 72 130 Y PFOA 431 100% 71 133 Y PFNA 446 104% 69 130 Y PFDA 403 94.0% 71 129 Y PFUnA 411 95.8% 69 133 Y PFDoDA 421 98.2% 72 134 Y PFTrDA 398 92.8% 65 144 Y PFTeDA 400 93.4% 71 132 Y Sulfonates L-PFBS 359 94.5% 72 130 Y PFPeS 437 108% 71 127 Y PFHxS 409 105% 68 131 Y PFHpS 459 113% 69 134 Y PFOS 398 100% 65 140 Y PFNS 373 90.7% 69 127 Y PFDS 336 81.3% 53 142 Y Other PFOSA 353 82.3% 68 141 Y N-MeFOSAA 474 111% 65 136 Y N-EtFOSAA 438 102% 61 135 Y EU#0819-709 12 of 25 f, L THALPY A t. Y "I' z C..: A. I. OPR Detailed Results-PFAS Lab/Sample Details Matrix: Aqueous Date Received: N/A Lab Sample ID: OPR_10443 Wt./Vol. 30.0 Date Extracted: 03-Sep-19 QC Batch#: 10443 Date Analyzed: 04-Sep-19 Final Volume(mL) 0.4 Time Analyzed: 11:21:46 Analyte CAS Number Conc.(ng/L) MDL(ng/L) RL(ng/L) Qualifiers Standard ES Recoveries Qualifiers Acids MPFBA 92.3 PFBA 375-22-4 384 1.31 12.0 M5PFPeA 97.8 PFPeA 2706-90-3 411 0.748 12.0 M3PFBS 90.0 PFHxA 307-24-4 434 1.31 12.0 M5PFHxA 96.6 PFHpA 375-85-9 418 0.579 12.0 M4PFHpA 94.4 PFOA 335-67-1 431 0.662 12.0 M3PFHx5 110 PFNA 375-95-1 446 0.424 12.0 M8PFOA 92.5 PFDA 335-76-2 403 1.04 12.0 M9PFNA 76.7 PFUnA 2058-94-8 411 0.401 12.0 M8PFOS 85.5 PFDoDA 307-55-1 421 0.396 12.0 M8FOSA 81.8 PFTrDA 72629-94-8 398 0.621 12.0 M6PFDA 92.2 PFTeDA 376-06-7 400 0.692 12.0 d3-N-MeFOSAA 75.5 d5-N-EtFOSAA 84.3 Sulfonates M7PFUdA 86.5 L-PFBS 375-73-5 359 0.692 12.0 MPFDoA 73.3 PFPeS 2706-91-4 437 0.825 12.0 M2PFTeDA 19.8 Q PFHxS 355-46-4 409 0.689 12.0 PFHpS 375-92-8 459 0.649 12.0 PFOS 1763-23-1 398 0.392 12.0 PFNS 68259-12-1 373 0.545 12.0 PFDS 335-77-3 336 1.12 12.0 Other PFOSA 754-91-6 353 3.04 12.0 N-MeFOSAA 2355-31-9 474 0.453 12.0 N-EtFOSAA 2991-50-6 438 0.543 12.0 EU#0819-709 13 of 25 .... A N A L Y F I C A I., 1 Method Blank Detailed Results-PFAS Lab/Sample Details Matrix: Aqueous Date Received: N/A Lab Sample ID: MB_10443 Wt./Vol. 30.0 Date Extracted: 03-Sep-19 QC Batch U: 10443 Date Analyzed: 04-Sep-19 Final Volume(mL) 0.4 Time Analyzed: 11:10:35 Analyte CAS Number Conc.(ng/L) MDL(ng/L) RL(ng/L) Qualifiers Standard ES Recoveries(%) Qualifiers Acids MPFBA 89.1 PFBA 375-22-4 ND 1.31 12.0 U M5PFPeA 97.9 PFPeA 2706-90-3 ND 0.748 12.0 U M3PFBS 79.8 PFHxA 307-24-4 ND 1.31 12.0 U MSPFHxA 91.7 PFHpA 375-85-9 ND 0.579 12.0 U M4PFHpA 95.2 PFOA 335-67-1 ND 0.662 12.0 U M3PFHxS 99.9 PFNA 375-95-1 ND 0.424 12.0 U M8PFOA 89.7 PFDA 335-76-2 ND 1.04 12.0 U M9PFNA 82.2 PFUnA 2058-94-8 ND 0.401 12.0 U M8PFOS 90.1 PFDoDA 307-55-1 ND 0.396 12.0 U M8FOSA 101 PFTrDA 72629-94-8 ND 0.621 12.0 U M6PFDA 86.7 PFTeDA 376-06-7 ND 0.692 12.0 U d3-N-McFOSAA 78.8 d5-N-EtFOSAA 92.2 Sulfonates M7PFUdA 87.2 L-PFBS 375-73-5 ND 0.692 12.0 U MPFDoA 76.9 PFPeS 2706-91-4 ND 0.825 12.0 U M2PFTeDA 60.8 PFHxS 355-46-4 ND 0.689 12.0 U PFHpS 375-92-8 ND 0.649 12.0 U PFOS 1763-23-1 ND 0.392 12.0 U PFNS 68259-12-1 ND 0.545 12.0 U PFDS 335-77-3 ND 1.12 12.0 U Other PFOSA 754-91-6 ND 3.04 12.0 U N-MeFOSAA 2355-31-9 ND 0.453 12.0 U N-EtFOSAA 2991-50-6 ND 0.543 12.0 U EU#0819-709 14 of 25 Narrative Summary N HALPY EU#0819-709 15 of 25 Enthalpy Analytical Narrative Summary Company Siler City WWTP Job# 0819-709 PFAS - DEQ list Client Project# n/a Custody Braidy May of Enthalpy Analytical Wilmington received the sample(s) (via courier)on 08/06/19 on ice at 8.9°C in good condition. Prior to, during, and after analysis, the sample(s) was stored in the laboratory with access only by authorized personnel of Enthalpy Analytical, LLC. Analysis The sample(s) was analyzed by isotope dilution method for PFAS using Waters Acquity UPLC equipped with Xevo TQ MS (LC/MS/MS"Kili"). For aqueous samples, the entire sample (approximately 30mL) was weighed and spiked with Extraction Standard(ES). The sample was then mixed well and centrifuged. Cleanup procedures were performed on the supernatant and then extracted via SPE. Each final sample extract was transferred to an autosampler vial and spiked with 400 µL of Injection Standard(IS),prior to analysis. Calibration The analytes and labeled standards of interest in the initial calibration (ICAL) exhibited RSDs less than 50%. All analytes passed the R2 coefficient correlation criteria with the exception of M8FOSA.The Initial calibration verification (ICY) and continuing calibrations (concals) met h ±50%the 30/o criteria for native analytes and criteria for ES recoveries. Y QC Notes The QC injection met the ±50% criteria for ES recoveries with the exception of M2PFTeDA, which fell outside the lower limit. The QC injection met±30% Recovery criteria of target concentration. Due to % Recovery criteria being met and limited sample available for extraction, data is reported. The method blank contained no analytes and met ES recovery criteria. The samples were initially extracted within the 14-day from collection holding time (Aug 13), however re-extraction was outside the 14-day hold time (Sep 3). Data should not be affected by the additional time as data shows stability for up to 70 days. Extracts were analyzed within the 28-days from extraction to analysis holding time required by the method. Reporting Notes During the initial analysis, QC parameters for the method blank did not meet method criteria for several analytes. This required re-extraction of the batch. This report contains data from the re-extracted sample indicated by an"R" in the Lab ID. I T " AL PY EU#0819-709 16 of 25 Enthalpy Analytical Narrative Summary (continued) Reporting Notes Some analytes in the samples fell outside the limits for ES recoveries, (continued) notated with a"Q" qualifier. It is concluded to be due to matrix effects. Based on the native results in the OPR meeting criteria,the out-of-range ES recoveries have no impact on the accuracy of the target analyte (native) compounds. Therefore,the data are considered acceptable. The results presented in this report are representative of the samples as provided to the laboratory. The samples, calibrations and standards for the data presented in this report were analyzed at 2714 Exchange Drive, Wilmington,NC 28405. EVE`11 EU#0819-709 17 of 25 General Reporting Notes — Data Qualifiers f NI'1.1 ALPY The following are general reporting notes that are applicable to all Enthalpy Analytical, Inc.-Wilmington, NC data reports, unless specifically noted otherwise. General Data Qualifiers/Data Attributes • B—The analyte was found in the method blank,at a concentration that was at least 10%of the concentration in the sample. • C—Two or more congeners co-elute. In EDDs,C denotes the lowest IUPAC congener in a co- elution group and additional co-eluters for the group are shown with the number of the lowest IUPAC co-eluter. • E—The reported concentration exceeds the calibration range(upper point of the calibration curve). • EMPC—Represents an estimated maximum possible concentration. EMPCs arise in cases where the signal/noise ratio is not sufficient for peak identification(the determined ion-abundance ratio is outside the allowed theoretical range), or where there is a co-eluting interference. • J—Indicates that an analyte has a concentration below the reporting limit(lowest point of the calibration curve). • L-Indicates that an analyte has a concentration below the Minimum Detection Limit(MDL). • ND—Indicates a non-detect. • NR—Indicates a value that is not reportable. • PR—Due to interference,the associated congener is poorly resolved. • DI—Indicates the presence of a quantitative interference. • SI—Denotes"Single Ion Mode"and is utilized for PCBs where the secondary ion trace has a significantly elevated noise level due to background PFK. Responses for such peaks are calculated using an EMPC approach based solely on the primary ion area(s)and may be considered estimates. • U—The analyte was not detected. The Estimated Detection Limit(E DL)( DL)may be reported for this analyte. • V—The labeled standard recovery was found to be outside of the method control limits. DRBC/TMDL Specific Data Qualifiers/Data Attributes • J—The reported result is an estimate. The value is less than the minimum calibration level but greater than the Estimated Detection Limit(EDL). • U—The analyte was not detected in the sample at the Estimated Detection Limit(EDL). EU116_v0(General Reporting Notes-Data Qualifiers) Enthalpy Analytical, Inc.—Wilmington,NC EU#0819-709 18 of 25 0-0 General Reporting Notes — Data Qualifiers • E—The reported concentration is an estimate. The value exceeds the upper calibration range (upper point of the calibration curve). • D—Dilution Data. Result was obtained from the analysis of a dilution. • B—Analyte found in the sample and associated method blank. • Cxx—Co-elutes with the indicated congener,data is reported under the lowest IUPAC congener. `xx' denotes the IUPAC number with the lowest numerical designated congener. • NR—Analyte is not reportable because of problems in sample preparation or analysis. • V—Labeled standard recovery is not within method control limits. • X—Results from re-injection/repeat/second-column analysis. • EMPC—Estimated Maximum Possible Concentration. Indicates that a peak is identified but did not meet the method specified ion-abundance ratio. Lab Identifiers • AR—Indicates use of the archived portion of the sample extract. • CU—Indicates a sample that required additional clean-up prior to FIRMS injection/processing. • D—Indicates a dilution of the sample extract. The number that follows the "D"indicates the dilution factor. • DE—Indicates a dilution performed with the addition of ES(Extraction Standard)solution. • DUP—Designation for a duplicate sample. • MS—Designation for a matrix spike. • MSD—Designation for a matrix spike duplicate. • RJ—Indicates a reinjection of the sample extract. • S—Indicates a sample split. The number that follows the"S"indicates the split factor. EU116_v0(General Reporting Notes-Data Qualifiers) Enthalpy Analytical,Inc.—Wilmington,NC EU#0819-709 19 of 25 Attachment B To locate a lab capable of performing the PFAS analysis, please visit https://www.denix.osd.mil/edqw/accreditation/accreditedlabs/and search by method"PFAS by LCMSMS Compliant with Table B-IS of QSM 5.1 or Latest Version". Grab samples are required to avoid cross- contamination and ensure consistency. It,is the Division's understanding that this test method is capable of providing results for the listed PFAS compounds listed below. The Division recognizes that there may be variations from lab to lab. Each facility shall provide results for PFOA, PFOS,and shall include as many of the following PFAS compounds as possible: Analyte Name Acronym Fluorinated ; Molecular CAS Carbon Formula Number Chain Length Perfluorotetradecanoic acid PFTeA CI4 Ci,F27COOH 376-06-7 Perfluorotridecanoic acid PFTriA Ci, Ci2F29COOH 72629-94-8 Perfluorododecanoic acid PFDoA C12 C1,F21COOH 307-55-1 Perfluoroundecanoic acid PFUnA CH CwF2,COOH 2058-94-8 ICI Perfluorodecanoic acid PFDA Cm ' C9F19COOH 335-76-2 Perfluorononanoic acid PFNA C, C8F17COOH 375-95-I Perfluorooctanoic acid PFOA Ca C7Fi5COOH 335-67-1 Perfluorohepanoic acid PFHpA C7 C6F13COOH 375-85-9 Perfluorohexanoic acid PFHxA C, C5F1'COON 307-24-4 Perfluoropentanoic acid PFPeA C, C4F9COOH 2706-90-3 Perfluorobutanoic acid PFBA C4 C3F7COOH 375-22-4 Perfluorodecanesulfonic acid PFDS Co C10F21SO3H 335-77-3 Perfluorononanesulfonic acid PFNS Co C9F19S03H 68259-12-1 Perfluorooctanesulfonic acid PFOS C„ C8F17S03H 1763-23-1 Perfluoroheptanesulfonic acid PFHpS C, C7FisSO3H 375-92-8 Perfluorohexanesulfonic acid PFHxS C6 C6FI3S03H 355-46-4 Perfluoropentanesulfonic acid PFPeS C, C5F>>S03H 2706-91-4 Perfluorobutanesulfonic acid PFBS C4OMG C4F9SO3H 375-73-5 Perfluorooctanesulfonamide PFOSA Cs C8F17S02NH2 754-91-6 2-(N-Ethylperfluorooctanesulfonamido) N-EtFOSAA Cm C8Fi7S02N(C2H5) 2991-50-6 acetic acid CH2COOH 2-(N-Methylperfluorooctanesulfonamido) ! N-MeFOSAA Cs C8Fi7S02N(CH3) 2355-31-9 acetic acid CHCOOH EU#0819-709 20 of 25 PFAS Compound Acronym List Acronym I Compound Name Target Analytes PFBA Perfluorobutanoic Acid PFPeA Perfluoropentanoic Acid PFHxA Perfluorohexanoic Acid PFHpA Perfluoroheptanoic Acid PFOA Perfluorooctanoic Acid PFNA Perfluorononanoic Acid PFDA Perfluorodecanoic acid PFUnDA Perfluoroundecanoic acid PFDoDA(PFTDDA) Perfluorododecanoic acid PFTrDA(PFTrA) Perfluorotrdecanoic acid PFTeDA(PFTA) Perfluorotetradecanoic acid PFBS Perfluorobutane sulfonate PFPeS Perfluoropentane sulfonate PFHxS Perfluorohexane sulfonate PFHpS Perfluoroheptane sulfonate PFOS Perfluorooctane sulfonate PFNS Perfluorononane sulfonate PFDS Perfluorodecane sulfonate 4:2 FTS 4:2 fluorotelomer sulfonic acid 6:2 FTS 6:2 fluorotelomer sulfonic acid 8:2 FTS 8:2 fluorotelomer sulfonic acid PFOSA Perfluorooctane sulfonamide N-MeFOSAA N-methyl perfluorooctane sulfonamido acetic acid N-EtFOSAA N-ethyl perfluorooctane sulfonamido acetic acid HFPO-DA 2,3,3,3-Tetrafluoro-2-(1,1,2,2,3,3,3-heptafluoropropoxy)-propanoic acid(Gen-X) Extraction Standards M3PFBA Perfluoro-n-[2,3,4-13C3]butanoic acid M5PFPeA Perfluoro-n-[13C5]pentanoic acid M3PFBS Sodium perfluoro-1-[2,3,4-13C3]-butanesulfonate M2-4:2 FTS Sodium 1H,1H,2H,2H-perfluoro-1-[1,2-13C2]-hexane sulfonate M5PFHxA Perfluoro-n-[1,2,3,4,6-13C5]hexanoic acid M3HFPO-DA 2,3,3,3-Tetrafluoro-2-(1,1,2,2,3,3,3-heptafluoropropoxy)-13C3-propanoic acid M4PFHpA Perfluoro-n-[1,2,3,4-13C4]heptanoic acid M3PFHxS Sodium perfluoro-1-[1,2,3-13C3]-hexanesulfonate M2-6:2 FTS Sodium 1H,1H,2H,2H-perfluoro-1-[1,2-13C2]-octane sulfonate M8PFOA Perfluoro-n-[13C8]octanoic acid M9PFNA Perfluoro-n-[13C9]nonanoic acid M8PFOS Sodium perfluoro-1-[13C8]-octanesulfonate M2-8:2 FTS Sodium 1H,1H,2H,2H-perfluoro-1-[1,2-13C2]-decane sulfonate M8FOSA Perfluoro-1-[13C8]octanesulfonamide M6PFDA Perfluoro-n-[1,2,3,4,5,6-13C6]decanoic acid d3-N-MeFOSAA N-methyl-d3-perfluoro-1-octanesulfonamide d5-N-EtFOSAA N-ethyl-d5-perfluoro-1-octanesulfonamide M7PFUnDA(M7PFUdA) Perfluoro-n-[1,2,3,4,5,6,7-13C7]undecanoic acid MPFDoA Perfluoro-n-[1,2-13C2]dodecanoic acid M2PFTeDA Perfluoro-n-[1,2-13C2]tetradecanoic acid .�,. EU#0819-709 21 of 25 Injection Standards MPFBA Perfluoro-n-[13C4]butanoic acid M2PFOA Perfluoro-n-[1,2-13C2]octanoic acid MPFDA Perfluoro-n-[1,2-13C2]decanoic acid MPFOS Sodium perfluoro-1-[1,2,3,4-13C4]-octanesulfonate 4111 Ni I 11 A L# i EU#0819-709 22 of 25 Sample Custody ENT1 IP) EU#0819-709 23 of 25 0 1g L q "--- '4-- 0 9 . Special Handling: , I / S ,E7 Standard Turn Around Time 4. Chain of Custody Record 0 Rush Tum Around Time--Date Needed •All Fast TATs Subject to Approval by Enthalpy Analytical,Inc. 1 „ :, t •All Samples Disposed of After 6 months Unless Otherwise Instructed. EN1"'E-/ALPY Enthalpy Ultratrace Job#: (:OC Page of Enthalpy Analytical-Wilmington,NC has added enhancements to standard methods to improve accuracy, precision and permit an assessment of laboratory performance m the context of your specific data needs.For x) 1 s._'t more information email Cindy lames@enthalpy.com. Client Name: r ISM C t't'-i' LJ\.'\3T{ Project Number: , PO#: This Chain of Custody is applicable to Project Manager. Site Name r 't Telephone#: Non-Air samples Standard TAT differ ,-- � € per analysis and are provided by request. Report To: 4--�C.,,i t hi I S Location: Email k) h i i I<:` i-i<'t+`(,C- Client Special Instructions: Sample Containers Anal(ses: in U a rn w Matrix: GW-Groundwater,WW-Wastewater,NW-Non-Potable Water,OW-Drinking Water,S-Soil,SLStudge,BT- 0 2 E Biological Tissue,0-Other CO rA s a Type:G=Grab C=Composite Q Ouallty Control a oo oo 3 0 I x a m m a = o o m a a a a m Sample m It `13—, m L = L r a E (�(SSample ID Date + Time Volume Type Matrix uo u s 4t 2 2 2 a a. rn Notes: E"P._;11..4- 4�r ? _Lr�tc �'/0,..w a c t`_:` o -c \-cs- Relinquished By. Date. _ Received By: Date: Time: Sample Temperature Upon Receipt: % ' ` `= .-it ;�r � - r ���,t _ n -f"Ct 9:tY(ced o'Ambient °Cy 4, / , \ Gl'41 f'� � ❑ Iced ❑ Ambient °C 12-5 (t1 l 6 't 30 (Iced ❑ Ambient °C 0. q T a 2714 Exchange Drive•Wilmingt ,NC 28405•(910) 858•www.enthalpy.com LEA_ L&K.r ; e r, no seal ) Cond ;� � &n : 90 �i' cs© te<,1 Pa c.e -`�-f---L ce . b , i EU 0d19 09 24 of 25 1 J h ThisPage Is The Last Of This Report. „ ,, a I HALPY 0819-709 25 of 25 EU#