Loading...
HomeMy WebLinkAbout20191495 Ver 1_U-5537_Buffer Permit Drawings_20191009_20191104W O Pam 1308 APEX 1435 LOCATION CARY VICINITY MArj THERE IS NO CONTROL OF ACCESS ON THIS PROJECT. GRAPHIC SCALES DESIGN DATA 50 25 0 50 100 ADT 2017 = 13,150 ADT 2037 = 19,700 PLANS 50 25 0 50 100 T = 6 % V = 40 MPH PROFILE (HORIZONTAL) TTST = 2% DUAL = 4% 10 5 0 10 20 FUNC CLASS = MAJOR COLLECTOR/ PROFILE (VERTICAL) MAJOR THOROUGHFARE STATIC OF NORTH CAROLINA DIVISION OF HIGHWAYS WAKE COUNTY LOCATION: IMPROVEMENTS TO SR 1521 (LAKE PINE DR.) FROM EAST OF PINE PLAZA DR/MACGREGOR PINES DR. TO APEX TOWN LIMITS (NORTHEAST OF VERSAILLES DR.) PROJECT LENGTH LENGTH ROADWAY = 0.349 MILES LENGTH STRUCTURE = 0.007 MILES TOTAL LENGTH = 0.356 MILES -L- STA. 19+09.29 PL S PREPARED BY. 860] SIX FORKS RD, SUITE 260 RALEIGH, NC 27615 RSA 919-926-4100 FOR THE NORTH CAROLINA DEPARTMENT OF TRANSPORTATION 2018 STANDARD SPECIFICATIONS JARED BOND, PE PROJECT ENGINEER RIGHT OF WAY DATE. NOVEMBER 2016 SEAN KORTOVICH, El PROJECT DESIGN ENGINEER LETTING DATE: FEBRUARY 2020 RUSSELL DALTON, PE TOWN OF APEX PROJECT MANAGER �1`ATB WAT Pq BOr AffM$Ko W6 N. U-5537 I FAw "0. wft AAPw m. owawrim 44112.1.F1 STPDA-050134 PE 44112.2.1 STPDA-0501(34) ROW, UTIL 44112.3.1 STPDA-0501(34) CONST HYDRAULICS ENGINEER P.E. SIGNATURE: ROADWAY DESIGN ENGINEER P.E. SIGNATURE: 30' 0' 30' 60' 90, GRAPHIC SCALE TOWN OF APEX EST 1 TOP EST 5 SY �0 42" CLF 96�,T0 L0 96TO K >4" RCP INV e BRK Hey R/wr 42' CLF GAT�j, I — LATERAL BASE DITCH SEE DETAIL B EST 3 TONS CL B RIP RAP �� EST 10 SY GEOTEXTILE 0 LATERAL BASE i� DITC ETAIL A 1.97' OM STA. + 55 TO + 85 R 1 .59' Q2=2.57 S —iYLB V2=2.17 R S 9qg• Q10— CFS -Z50' VlO .31 FPS DETAIL A LATERAL BASE DITCH _ (Not to Scale) TER, LLC -WLB_ \ r �l Natural � O Ground ?.� D •y1 1'iF}• Fill S Slope I t L I {� ALLOWABLE IMPACTS ZONE 1 ROADWAY DESIGN HYDRAULICS ENGINEER ENGINEER INOMPLE E PLANT ALLOWABLE IMPACTS ZONE 2 0o NOT USE MR V. AcourSMON �J MITIGABLE IMPACTS ZONE 1 OS DOCUMENT NOT CONSIDERED FINAL N / MITIGABLE IMPACTS ZONE 2 UNLESS ALL SIGNATURES COMPLETE 13 BUFFER DRAWING SHEET 2 OF 5 > a I Min. D= 1.00 Ft. 4.=.! B = 2.00 Ft. b = 5.00 Ft. DDE = 25.2 CY FROM STA. 16+55 RT TO STA. 17+85 RT m LATERAL BASE DITCH C �> \ `—Sff E2 RIP RAP AT EMBANKMENT N- > <, SEE DETAIL D THIS SHEET N \i} N .y PF m O FREDERICK K. SCHWDT, ET UX DETAIL B LATERAL BASE DITCH ( Not to Scale) Natural Fill Ground ?'I D ry•1 1'iFt. Slope d GEOTEXTILE B Min. D= 1.50 Ft. Max. d = 1.50 Ft. B = 2.00 Ft. DDE = 103.7 CY 6= 5.00 Ft. Type of Liner= Class B Rip —Rap FROM STA. 18+92 LT TO STA. 20+50 LT DETAIL C LATERAL BASE DITCH ( Not to Scale) Natural Fill Ground D d �•1 1'iFt. Slope GEOTEXTI LE B Min. D= 1.50 Ft. Max. d- 1.50 Ft. DDE = 83.6 CY B= 2.00 Ft. Type of Liner= Class I Rip -Rap 6= 5.00 Ft. /FROM STA. 20 + 05 RT TO STA. 21 + 20 RT / DETAIL D RIP RAP AT EMBANKMENT ( Not to Scale) Natural 5'min. Groun 2.0'min. , 2• GEOTEXTILE DDE — 69.3 CY TYPE OF LINER — CL II RIP —RAP 94 TONS GEOTEXYILE = 104 SY FROM STA. 19+75 RT TO STA. 20+15 RT RIPARIAN BUFFER IMPACTS SUMMARY IMPACT BUFFER REPLACEMENT SITE NO. STRUCTURE SIZE / TYPE STATION (FROM/TO) TYPE ALLOWABLE MITIGABLE ROAD CROSSING BRIDGE PARALLEL IMPACT ZONE 1 (ft) ZONE 2 (ft) TOTAL (ft) ZONE 1 (ft) ZONE 2 (ft) TOTAL (ft) ZONE 1 (ft) ZONE 2 (ft) 1 15" Pi e/PSH 15+75 to 16+40 RT X 1234 1234 1 2' Base Ditch 16+00 to 17+95 RT X 7112 7112 2 15" Pie 18+04 to 18+54 LT X 746 746 2 RCBC/Base Ditch 18+27 to 19+86 LT X 3045 1389 4434 2 RCBC/Base Ditch 19+09 to 20+51 RT X 5137 1997 7134 3 Greenwa 23+59 to 25+92 LT X 283 4646 4929 TOTAL: 8465 8778 17243 7112 1234 8346 0 0 Rev. SEP 2016 WETLANDS IN BUFFER IMPACTS SUMMARY WETLANDS IN BUFFERS STATION ZONE 1 ZONE 2 SITE NO. (FROM/TO) (ft) (ft) 1 17+46 to 17+91 RT 626 TOTAL: 1 6261 0 N.C. DEPT. OF TRANSPORTATION DIVISION OF HIGHWAYS WAKE COUNTY PROJECT: WBS # U-5537 DATE 10/9/2019 SHEET 5 OF 5 ev. an 2009