Loading...
HomeMy WebLinkAbout20191224 Ver 1_Rev Buffer Map_20191101SYMBOL LEGEND EXISTING SEWER MANHOLE O PROPOSED FITTING GATE VALVE ►t PROPOSED WATER HYDRANT EXISTING WATER LINE w EXISTING SEWER LINE s PROPOSED WATER LINE w PROPOSED SEWER LINE s 40 w w EX. 12" WATER LINE v. 0 � STA.M 0+00 PG���1 Q Dc �\G����9� �� O < TOP 112.06 tb INV. OUT: 105.16 O a0 �a INV IN- 106.06 O yGP O a / BE�IN CONSTRUCTION S r w EX. MH #1 �-__ _ \ TOP 115.00 INV. OUT: 108.75 I I / 1\ O x_ INV. IN. 9.50 I I I 11 h ^ I oIb I69 z I I '\� I II I fIIIQ // 1 ✓ IIIII 0��2 CHAIN LINK ,, 5������ �•13 FENCE Q GF' @ G I I p'/ 30' EX. CREEK' 1 ?., ZONE 1 I 1 ri PROPOSEd I / /7 x GqS QPPO N 2 o II `ol Ga EI 12" DIP ii�il I i i / ��� Gqs //* F ���� I I/ III I I I BUFFER DISTURBANCE 1 4-00 EX. 1 II ATER I II „j+ 0I� ' I (400 S.F.) 12+00 > �. p9 Q� 11 I 1 W �J-�"71/(�==1.�� PROPOSED 12" D (FUTURE) 3 Q1 0 S / 1/ I S I S IS A \ I �1 O o \'J li l �I _-- _-_ _ cns �4-- cAS* _�a / gsiiH �\ \ 71. _ _inn _ �/ /, i -I � - GAS GA D \ -118 GWS 0'x 0 ZONE 1 9t\ '/ _--- \ BUFFER DIS _ __, _- RBAN\CE /� i��� - _�/ = - ucT ucT - _ �, (400 S.�\ \\_- �\\ / �/� / UGT uG \==11g Llc '� uGT _ 17 BUFFER DISTURBANCE WLSON ROAD � �\\ 1 (600 S.F.) \�1c9 SR 1332 ��� J�oOJ�? � _--_--- .62 60 PUBLIC R/W \ BUFFER DISTURBANCE ` \� (600 S.F.) ��\ �j Q�Fo, • GPg J,, - - - - - - - - - - - - - - - - - - - - _ 401-_\ EX. MH#3 TOP 116.19 INV. OUT: 104.79 INV. IN: 105.79 GRAPHIC SCALE 20 40 80 / TAT L V V IP N z" 1 SEALD I " 20106 - �,, �1 NG" �1111111 124 122 120 118 116 114 104 102 100 co O N PLAN VIEW EX. MH#2 STA 10+00.00 RIM 112.06 INV IN 109.00 INV OUT 106.06 276f MH#1STA 10+16.04 118.27 IN 109.85 (NW) V IN 109.85 (E) OUT 109.65 24" STEEL CASING WI H SPIDERS RIM OUTSIDE DROP INV .1 INV co cc O 00 N Ln O cc O 00 Ln O O 00 CO 00 00 N CO m N 00 OO m LO co OO 06 10+00 160 BARTLETT 11 +00 12+00 PROF/LE VIEW ENGINEERING & SURVEYING, PC 906 NASH STREET NORTH TELE: (252) 399-0704 IILSON, N.C. 27893-1726 FAX: (252) 399-0804 EMAIL: info®bartletteng.com SANITARY SEWER EXTENSION 124 122 120 118 116 114 112 110 108 106 104 102 100 LO co 06 12+77.38 AERIAL PIPE CROSSING GENERAL NOTES: 1, ALL MATERIALS UTILIZED ON THESE DETAIL SHEETS SHALL CONFORM TO NCDOT'S 2012 STANDARD SPECIFICATIONS FOR ROADS AND BRIDGES, AS WELL AS NCDENR'S MINIMUM DESIGN CRITERIA FOR THE PERMITTING OF GRAVITY SEWERS, UNLESS NOTED OTHERWISE HEREIN. 2• RESTRAINED JOINT PIPE AND FITTINGS SHALL CONSIST OF BOLTED RETAINER RINGS AND WELDED RETAINER BARS OR BOLTLESS TYPE WHICH INCLUDE DUCTILE IRON LOCKING SEGMENTS AND RUBBER RETAINERS. BOLTS FOR RESTRAINED JOINTS (IF APPLICABLE) SHALL CONFORM TO ANSI B18.2. RESTRAINED PIPE AND FITTINGS SHALL BE FLEX -RING OR LOK-RING TYPE JOINTS. 3. CONCRETE PROPERTIES SHALL BE AS FOLLOWS: CONCRETE COMPRESSIVE STRENGTH = 4000 PSI NOMINAL SLUMP = 4 INCHES WATER/CEMENTITOUS MATERIALS RATIO = 0.45 (MAX) AIR CONTENT = 6%' 1.5% CONCRETE SHALL BE COMPOSED OF CEMENT, WATER, COARSE AGGREGATES, FINE AGGREGATES AND AIR, CEMENT SHALL BE TYPE 1/I1 OR II IN ACCORDANCE WITH ASTM C-150. MATERIAL REQUIREMENTS FOR ALL FINE AND COARSE AGGREGATES SHALL CONFORM TO ASTM C-33, COARSE AGGREGATE SHALL BE SIZE No. 57 OR 67. AN APPROVED CLASS'F' FLYASH MAY BE SUBSTITUTED FOR AN EQUAL AMOUNT OF CEMENT BY WEIGHT UP TO 25%• 4. ALL EXPOSED CONCRETE CORNERS SHALL BE CHAMFERED 314", 5. CONVENTIONAL REINFORCING STEEL SHALL CONFORM TO ASTM A615 GRADE 60 AND SHALL BE PLACED IN ACCORDANCE WITH "RECOMMENDED PRACTICE FOR PLACING REINFORCING BARS" (LATEST EDITION) AS PUBLISHED BY THE CONCRETE REINFORCING INSTITUTE, SPLICES SHALL BE CLASS'B' CONFORMING TO THE PROVISIONS OF ACI 318 -"BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE", 6. NEOPRENE BEARING PADS SHALL BE FORMED FROM PREVIOUSLY UNVULCANIZED, 100% VIRGIN NEOPRENE, WITH DUROMETER HARDNESS = 50. VARIES TYP MIN 4'.0" i TYP 314" STAINLESS STEEL ANCHOR BOLTS & STRAPS CLASS I RIP -RAP SLOPE PROTECTION, TYP i- STEEL CASING PIPE CREEK CHANNEL OR FLOOD PLAIN ALLOWABLE SPANS FOR STEEL CASING PIPE CARRIER PIPE, DIP DIAMETER (IN.) CASING PIPE, STEEL DIAMETER (IN.) MINIMUM CASING PIPE WALL THICKNESS (IN.) ALLOWABLE SPAN (FT.) 6 14 0.3750 40 8 16 1 0.3750 45 10 18 1 0.3750 50 12 20 0.3750 60 14 24 0.3760 55 16 26 0.3760 55 18 30 0.3750 60 20 32 0.3750 60 24 36 OA375 65 30 42 OA375 65 36 48 0.600 1 66 42 55 1 0.5000 1 65 MANHOLE, TYP VC STAINLESS STEEL ANCHOR BOLTS & STRAPS DIP CARRIER RESTRAINED ED JOINT OIN FITTINGS BETWEEN CLASS I RIP -RAP SLOPE I CONCRETE PIER PROTECTION, TYP DIP CARRIER PIPE WITH RESTRAINED JOINT FITTINGS BETWEEN MANHOLES (SEE NOTE 4) EXTEND RIP -RAP 2'-0" PAST I WATER LINE, TYP 3'-W MIN FROM BOTTOM OF CREEK OR FLOOD PLAIN NOTES: 1. STEEL PIPE SHALL BE EITHER SPIRAL WELDED OR SMOOTH WALL SEAMLESS WITH A MINIMUM YIELD STRENGTH OF 35,000 PSI. PAINTING AND LINING SHALL BE AS REQUIRED BY NCDOT OR NCDENR. 2. DUCTILE IRON PIPE SHALL BE SUPPORTED WITH TWO SPIDERS AT EVERY JOINT WITHIN THE CASING PIPE USING APPROVED PIPE ALIGNMENT GUIDE. SEE DETAIL, THIS SHEET. ALL JOINTS SHALL BE RESTRAINED JOINT. SEE NOTE 2 OF THE AERIAL PIPE CROSSING GENERAL NOTES. 3, SUPPORT TYPE FOR PIERS SHALL BE DETERMINED BY ENGINEER BASED ON SUBGRADE CONDITIONS AT SITE. SEE AERIAL PIPE CROSSING DETAIL FOR CONCRETE PIER ON SHEET UT-06 FOR SUBGRADE PARAMETERS FOR EACH TYPE OF FOUNDATION. SEE AERIAL PIPE CROSSING DETAIL FOR CONCRETE SUPPORTS ON SHEET UT-05 FOR SUPPORTS PLACED WITHIN STREAM. 4. BOTTOM OF PIPE TO BE AT A MINIMUM OF V ABOVE THE 25 YEAR FLOOD ELEVATION. STEEL CASING PIPE ELEVATION NOT TO SCALE EXCAVATION AND GRADING PLAN NOTES: CONTRACTOR SHALL NOTIFY AND COOPERATE WITH ALL UTILITY COMPANIES OR FIRMS HAVING FACILITIES ON OR ADJACENT TO THE SITE BEFORE DISTURBING, ALTERING, REMOVING, RELOCATING, ADJUSTING OR CONNECTING TO SAID FACILITIES. UNUSABLE EXCAVATED MATERIALS AND ALL WASTE RESULTING FROM CLEARING AND GRUBBING SHALL BE DISPOSED OF OFF -SITE BY CONTRACTOR, AT AN APPROVED PERMITTED LOCATION. STRUCTURAL FILL: ALL NEWLY PLACED STRUCTURAL FILL OR BACK FILL SHOULD BE COMPACTED TO NOT LESS THAN 95% OF THE STANDARD PROCTOR MAXIMUM DRY DENSITY EXCEPT IN THE FINAL FOOT BENEATH PAVEMENT STRUCTURES WHERE THE REQUIREMENT SHOULD BE INCREASED TO 98% OF THE PROCTOR MAXIMUM DRY DENSITY. IT IS NOT ANTICIPATED THAT EITHER DIFFICULT EXCAVATION OR GROUND WATER WILL BE ENCOUNTERED FOR CUT DEPTHS UP TO 15 FEET ON THIS SITE. ALTHOUGH THE SOIL APPEARS TO BE WELL SUITED FOR REUSE AS STRUCTURAL FILL, IT SHOULD BE RECOGNIZED THAT CLAY SOILS ARE SENSITIVE TO MOISTURE; AND THEREFORE, IT IS RECOMMENDED THAT EARTHWORK BE PERFORMED DURING THE DRIER MONTHS OF THE YEAR. THE CONTRACTOR SHOULD BE PREPARED TO MOISTURE CONDITION THE SOILS AS NECESSARY IN ORDER TO IMPROVE THE EFFICIENCY OF THE COMPACTING OPERATIONS AND EFFORTS. OFFSITE BORROW / TRENCH BORROW: OFFSITE BORROW MATERIAL PLACED ON SITE SHOULD BE LOW PLASTICITY (PI LESS THAN 25 AND LL LESS THAN 50) AND SHALL BE FREE OF ORGANIC MATERIAL OR DEBRIS PLACE FILL IN 8" TO 10" LOOSE LIFTS AND COMPACT TO 95% OF THE STANDARD PROCTOR MAXIMUM DRY DENSITY, ASTM D698. THE MOISTURE CONTENT OF THE SOIL SHOULD BE MAINTAINED WITHIN t 3 PERCENTAGE POINTS OF THE OPTIMUM MOISTURE CONTENT DETERMINED BY THE SAME TEST. OFF -SITE BORROW MATERIAL TO BE OBTAINED FROM A PERMITTED SOURCE. EXISTING CONDITIONS: THE CONTRACTOR SHALL BE RESPONSIBLE FOR REVIEWING ALL EXISTING JOB CONDITIONS. ANY ADVERSE CONDITIONS AFFECTING WORK SHOWN ON THESE DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER FOR POSSIBLE CLARIFICATION OR RECONCILIATION. CONSTRUCTION SAFETY: THESE DRAWINGS DO NOT CONTAIN THE REQUIREMENTS FOR JOB SAFETY. ALL PROVISIONS FOR SAFETY SHALL BE SOLE RESPONSIBILITY OF THE CONTRACTOR. GENERAL NOTES: CALL ONE CALL CENTER AT 1-800-632-4949 FOR LOCATIONS OF EXISTING UTILITIES 48 HOURS MINIMUM PRIOR TO EXCAVATION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL WORK ZONE TRAFFIC CONTROL. ALL METHODS SHALL CONFORM TO THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD) AND NCDOT STANDARDS. PARKING & DRIVE AREAS TO BE REPAIRED WITH A MINIMUM 4" CABC. LAKE WILSON 2019 PARK IMPROVEMENTS IT TI IEl STEEL CASING PIPE, SEE AERIAL PIPE CROSSING DETAIL FOR STEEL CASING PIPE ELEVATION ON THIS SHEET. � O b EDGE OF WATER. SEE AERIAL PIPE CROSSING DETAIL FOR CASING PIPE ON SHEET UT-05 18" FOR SUPPORTS PLACED IN 18" STREAM TYP TYP NOTES: 1. RIP RAP FOR SLOPE PROTECTION SHALL BE CLASS I RIP RAP IN ACCORDANCE WITH SECTION B68 OF THE NORTH CAROLINA DEPARTMENT OF TRANSPORTATION'S "STANDARD SPECIFICATIONS FOR ROADS AND BRIDGES". 2• RIP RAP SHALL BE PLACED IN ACCORDANCE WITH DRAWING 868.01 OF THE NORTH CAROLINA DEPARTMENT OF TRANSPORTATION'S "ROADWAY STANDARD DRAWINGS", 3. SUPPORT TYPE FOR PIERS SHALL BE DETERMINED BY ENGINEER BASED ON SUBGRADE CONDITIONS AT SITE. SEE AERIAL PIPE CROSSING DETAIL FOR CONCRETE PIER ON SHEET UT-05 FOR SUBGRADE PARAMETERS FOR EACH TYPE OF FOUNDATION. 4. WHERE DUCTILE IRON PIPE IS USED FOR CARRIER PIPE, DUCTILE IRON CARRIER PIPE SHALL BE INSTALLED UTILIZING 2 PIPE ALIGNMENT GUIDES PER JOINT ONE FOURTH OF THE PIPE JOINT LENGTH IN FROM BOTH THE BELL AND SPIGOT ENDS. AERIAL PIPE CROSSING TYPICAL PLAN NOT TO SCALE 1ANY STAINLESS STEEL STRAP WITH 114"x2112" NEOPRENE PAD ADHERED TO STRAP (SEE NOTE 5) 114"x6" NEOPRENE PAD --� ADHERED TO SADDLE 3 CASING PIPE DIA, "D" (IN.) "H" (FT.) THICKNESS "A" (IN.) PIER WIDTH "B" (FT.) FOOTING LENGTH "C" (FT.) FOOTING WIDTH "D' (FT.) 8.12 _< 6 12 2'4" 5'-6" T-W 8 12 2'4" V-3" 3'-V 10 12 2'4• V-8" 3'-0" 12 12 2'4" 7-2" 3'-0" 14.20 < 6 12 3'-0" 8'-0" T-0" 8 12 3'-0" 9'-0" 3'-0" 10 12 3'-0" 9'-I W 3'-0" 12 14 Y-W 10'•6" Y-0" 22-28 _< 6 14 T-8" 8'4' 4'-0" 8 14 3'-8"- 10'-0" T-0" 10 14 T-8" N'-0" 4'-0" 12 14 T-V 11'-10" 4,-0" _< 6 18 4'4" 9'-0" 4'-0' 30.36 8 18 4'4" IW-6" 4'-0". 10 18 4'-4" 11'-6" 4'-0" 12 18 4'4" 12'-4" 4'-0" 5 6 18 5'4" 9'-6" 6'-V 8 18 5'-0" 111-0" 5'-0" 3848 10 18 54' 12'-0" 5'-0" 12 18 5'4" 12'-10, V-0" 5156 < s 18 s'4" 9'-10, VW 8 18 fi'4" 11'4" 5' 0" 10 18 6-4" 12'-4" 6.0" 12 18 614" 13'-2" 6-0- DATE: AUG. 2019 PROJECT: 09-013 CLIENT CODE: WC SCALE(HORZ1 CADFILE: 18307-CP6 �� = 40' FIELD BOOK: SCALE(VERT): DRAWN BY: LR, CM 1» = 4' SURVEY BY: KP,DB,TD REVISIONS: ADDED DETAILS 8-5-19 MANHOLE, TYP SNUG FIT 314" 0 STAINLESS STEEL ANCHOR BOLTS, ASTM j120V* A307 OR A36 SEE NOTE 4 FOR BAR SIZE AND SPACING NOTES: 1. SHALLOW FOUNDATION DESIGN SHOWN ON THIS DETAIL IS BASED ON THE FOLLOWING PARAMETERS: ALLOWABLE SOIL BEARING CAPACITY = 2000 PSF CONCRETE COMPRESSIVE STRENGTH =400D PSI GRADE 60 REINFORCING STEEL MAXIMUM STREAM VELOCITY =10 FTISEC MAXIMUM SUPPORT HEIGHT (11) =12L W IF FIELD CONDITIONS REQUIRE ANY DEVIATION FROM THESE PARAMETERS, THE FOUNDATION DESIGN SHALL BE REVIEWED BY A STRUCTURAL ENGINEER. 2. IF SUBGRADE AT LOCATION OF SUPPORTS IS DEEMED UNABLE TO WITHSTAND 2000 PSF BEARING PRESSURE, A PILE SUPPORTED FOUNDATION SHALL BE UTILIZED AS PER DETAILS ON THIS SHEET. 3. IF BEDROCK IS ENCOUNTERED WHICH WILL PREVENT 3-FEET MINIMUM COVER OVER FOOTING, DOWELS SHALL BE DRILLED INTO BEDROCK PRIOR TO PLACING FOUNDATION. SEECONCRETE PIER ON BEDROCK DETAIL, THIS SHEET. 4. TWELVE -INCH AND FOURTEEN -INCH THICK PIERS AND FOOTINGS SHALL BE REINFORCED WITH #5 BARS AT 12 INCHES GO IN EACH DIRECTION ON EACH FACE. EIGHTEEN -INCH WIDE PIERS AND FOOTINGS SHALL BE REINFORCED WITH #7 BARS AT 12 INCHES OO IN EACH DIRECTION ON EACH FACE. S. EIGHTEEN4NCH THICK PIERS SHALL REQUIRE TWO STRAPS OVER THE PIPE INSTEAD OF ONE (AS SHOWN). 6. WHEN CONCRETE SUPPORTS ARE REQUIRED TO BE LOCATED WITHIN A STREAM AND ARE NOT COVERED WITH BACKFILL, SEE CONCRETE SUPPORT DETAIL, THIS SHEET FOR MODIFICATIONS TO UPSTREAM FACE OF SUPPORT. CONCRETE PIER DETAIL .NOT TO SCALE WATER, SEWER, AND STORM DRAINAGE LINES SHOULD BE CONSTRUCTED TO THE FOLLOWING SPECIFICATIONS: -MIN. 10' LATERAL SEPARATION BETWEEN WATER/SEWER LINES. -MIN. 18" VERT. SEPARATION BETWEEN WATER/SEWER, IF WATER MUST BE PLACED BELOW SEWER, DUCTILE IRON IS REQUIRED ON BOTH LINES. DUCTILE IRON SHOULD EXTEND 10' PAST INTERSECTION ON WATER LINE AND TO THE NEXT MANHOLE ON SEWER LINE PER CITY OF WILSON SPECIFICATIONS. -WATER/SEWER CROSSINGS SHALL BE ARRANGED SO THAT SEWER JOINTS ARE EQUIDISTANT AND AS FAR AS POSSIBLE FROM THE WATER MAIN JOINTS. -MIN. 24" VERT. SEPARATION BETWEEN STORM DRAIN AND SAN. SEWER OR DUCTILE IRON IS REQUIRED. CITY OF WILSON NORTH CAROLINA PIN # WILSON COUNTY ZONE: OS SHEET CP6 P:\-CADD\-LANDPROJECTS\WC\18307\DWG\18307-CP6.DWG 11 /1 /2019 11: 20: 03 AM