HomeMy WebLinkAboutSW6191002_SuppEZ-2018-Version-2.1.1 2019_10/30/2019SUPPLEMENT-EZ COVER PAGE
FORMS LOADED
PROJECTINFORMATION
1 Project Name FORT BRAGG SPECIAL OPERATIONS FACILITY
2
Project Area (ac)
2.59
3
Coastal Wetland Area ac
0
4
Surface Water Area ac
0
j 5
Is this proiect High or Low Density?
High
6
Does this project use an off -site SCM?
No
CO_MPLIAN_CE_WITH 02H .1003(4)
7
Width of ve elated setbacks provided feet
2
8
Will the vegetated setback remain vegetated?
Yes
9
Is BUA other that as listed in .1003 4 c-d out of the setback?
No
10
Is streambank stabilization proposed on this project?
No
NUMBER AND TYPE OF SCMs:
11
Infiltration S stem
0
12
Bioretention Cell
1
13
Wet Pond
0
14
Stormwater Wetland
0
15
Permeable Pavement
0
16
ISand Filter
0
17
Rainwater Harvesting RWH
0
18
Green Roof
0
19
Level Spreader -Filter Strip LS-FS
0
20
Disconnected Impervious Surface (DIS)
0
21
Treatment Swale
0
22
Dry Pond
1
23
StormFilter
0
24
Silva Cell
0
25
Bayfilter
0
26
Filterra
0
FORMS LOADED
DESIGNER CERTIFICATION
27
Name and Title:
JERRY OBERHOLTZER PROJECT MANAGER
28
O anization:
LOWE ENGINEERS
29
IStreet address:
990 HAMMOND DRIVE SUITE 900
30
City, State Zip:
ATLANTA, GA 30328
31
Phone numbers :
770 857-8400
32
Email:
JERRY.OBERHOLTZER@LOWEENGINEERS.COM
Certification Statement:
I certify, under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or
supervision; that the information provided in the form is, to the best of my knowledge and belief, true, accurate, and complete; and
that the engineering plans, specifications, operation and maintenance agreements and other supporting information are consistent
with the information provided here.
Signature of Designer
10-04-2019
Date
DRAINAGE AREAS
1 Its this a high density project? YES
2 1 If so, number of drainage areas/SCMs 2
Is all/part of this project subject to previous rule
3 versions? No
FORMS LOADED
DRAINAGE AREA INFORMATION
Entire Site
1 j _ _2_ P
4
Type of SCM
BIORETENTION
CELL
DETENTION
POND
5
Total BUA in project s ft
49086 sf
32453 sf
S
6permitting)
New BUA on subdivided lots (subject to
s ft
48192 sf
32453 sf
7permitting)
New BUA outside of subdivided lots (subject to
s
8
Offsite - total area (sq ft
9
Offsite BUA (sq ft
10
Breakdown of new BUA outside subdivided lots:
Parking (sq ft
26341 sf
13225 sf
f
Sidewalk (sq ft
3352 sf
1155 sf
Roof (sq ft
17090 sf
17090 sf
Roadway s ft
I�
Future (sq ft
Other, please specify in the comment box
below (sg ft
1409 sf
870 sf
11
New infiltrating permeable pavement on
subdivided lots (sq ft
12
New infiltrating permeable pavement outside of
subdivided lots (sq ft
13permitting)
Exisitng BUA that will remain (not subject to
s ft
894 sf
113 sf
14
Existing BUA that is already permitted (sq ft
894 sf
113 sf
15
Existing BUA that will be removed (sq ft
sf
sf
♦ 16
Percent BUA
44%
57%
0%
17
Design storm inches
2 in
2 in
2 in
18
Design volume of SCM cu ft
8880 cf
6435 cf
2087 cf
19
Calculation method for design volume
SCS
SCS
j SCS
ADDITIONAL INFORMATION
20
Please use this space to provide any additional information about the
drainage area(s):
Other proposed BUAs include pads for water chillers and a transformer.
1
BIORETENTION CELL
1 IDrainage area number j
83
2 Design volume of SCM (cu ft) �� 6435 cf
GENERAL MDC FROM 0 05
3 Is the SCM sized to treat the SW from all surfaces at build -outs No
4
Is the SCM located away from contaminated soils?
Yes
5 lWhat
are the side slopes of the SCM (H:V)?
3:1
6
Does the SCM have retaining walls, gabion walls or other engineered side
slopes?
No
7
Are the inlets, outlets, and receiving stream protected from erosion (10-
year storm)? I
Yes
8
Is there an overflow or bypass for inflow volume in excess of the design
volume? I
Yes
9
What is the method for dewatering the SCM for maintenance?
Pump (preferred)
10
If applicable, will the SCM be cleaned out after construction?
Yes
11
Does the maintenance access comply with General MDC (8)?
Yes
12
Does the drainage easement comply with General MDC (9)?
13
If the SCM is on a single family lot, does (will?) the plat comply with
General MDC (10)?
14
Is there an O&M Agreement that complies with General MDC (11)?
Yes
15
Is there an O&M Plan that complies with General MDC (12)?
Yes
16
Does the SCM follow the device specific MDC?
Yes
17
Was the SCM designed by an NC licensed professional?
Yes
--
BIORETENTION
CELL MDC FROM 02H .1052
SHWT elevation (fmsl) 224.50
18
19
Bottom of the bioretention cell (fmsl)
226.50
20
Ponding depth of the design storm (inches)
12 in
21
Surface area of the bioretention cell (square feet)
6435 sf
22
Design volume of the bioretention cell (cubic feet)
6435 cf
23
Is the bioretention cell used for peak attenuation?
No
24
Depth of peak attenuation over planting surface (in)
N/A
25
Height of peak attenuation outlet above the planting surface (in)
N/A
26
Infiltration rate of the in situ soil (inch/hour)
.4 in/hr
27
Diameter of the underdrain pipes (if applicable)
4 in
28
Does the design include Internal Water Storage (IWS)?
Yes
29
if so, elevation of the top of the IWS (fmsl)
228
30
Elevation of the planting surface (fmsl)
229.5
31
What type of vegetation will be planted? (grass, trees/shrubs, other)?
Grass
32
Media depth (inches)
30 in
33
Percentage of medium to coarse washed sand by volume
92%
34
Percentage of fines (silt and clay) by volume
4%
35
Percentage of organic matter by volume
3%
36
Type of organic material
PINE BARK
FINES
37
Phosphorus Index (P-Index) of media (unitless)
<50
38
Will compaction be avoided during construction?
Yes
39
Will cell be maintained to a one inch/hour standard?
Yes
40
Depth of mulch, if applicable (inches)
2 in
41
Type of mulch, if applicable
TRIPLE
SHREDDED
HARDWOOD
42
1 How many clean out pipes are being installed?
7
43
IType of pretreatment that will be used:
RIPRAP
ADDITIONAL INFORMATION
Please use this space to provide any additional information about the
44 bioretention cell(s):
Bioretention 3 7:57AM 10/4/2019
DRY POND
1 1Drainage area number 83
2 I Design volume of SCM (cu ft) 2087 cf
E L DC 5
Is the SCM sized to treat the SW from all surfaces
3 at build -out? No
4
Is the SCM located away from contaminated soils?
Yes
5
What are the side slopes of the SCM (H:V)?
3:1
6
Does the SCM have retaining walls, gabion walls or
other engineered side slopes?
No
7
Are the inlets, outlets, and receiving stream
protected from erosion (10-year storm)?
Yes
8
Is there an overflow or bypass for inflow volume in
excess of the design volume?
Yes
9
What is the method for dewatering the SCM for
maintenance? I
Pump (preferred)
10
If applicable, will the SCM be cleaned out after
construction?
Yes
11
Does the maintenance access comply with General
MDC (8)?
Yes
12
Does the drainage easement comply with General
MDC (9)?
13
If the SCM is on a single family lot, does (will?) the
plat comply with General MDC (10)?
14
Is there an O&M Agreement that complies with
General MDC (11)?
Yes
15
Is there an 0&M Plan that complies with General
MDC (12)?
Yes
16
Does the SCM follow the device specific MDC?
Yes
17
Was the SCM designed by an NC licensed
professional?
Yes
DRY POND
MDC FROM 02H .1062
18
SHWT elevation (fmsl)
219
19
Elevation of the bottom of the dry pond (fmsl)
219.5
20
Distance from bottom to SHWT (feet)
.5 ft
21
Elevation of the temporary pool during the design
storm (feet)
220.8 ft
22
Ponding depth of the design storm (feet)
.8 ft
23
Will the dry pond be uniformly graded to flow toward
the outlet?
Yes
24
Is a low flow channel being provided?
No
25
Are the inlet(s) and outlet located in a manner that
javoids short-circuiting?
Yes
26
Will berms or baffles be provided to increase the
flow path?
No
27
lWhat method of pretreatment will be provided?
RIPRAP
28
Diameter of drawdown orifice (in)
3 in
29
Drawdown time for the temporary pool (hours)
48
30
Does the pond minimize impacts to the receiving
channel from the 1-yr, 24-hr storm?
Yes
31
Is there a small permantent pool near the orifice to
prevent clogging?
Yes
32
Will the outlet be designed to prevent clogging?
Yes
33
Are the dam and embankment planted in non-
clumping turf grass?
Yes
34
Species of turf that will be used on the dam and
lembankment
HYBRID
BERMUDAGRAS
S
35
Will trees and shrubs be prevented from growing on
the dam and embankment?
as
ADDITIONAL
_ �� —a — .T _ -_ .—z _----
INFORMATION
36
Please use this space to provide any additional
information about the infiltration system(s):
Dry Pond 4 7:57 AM 10/4/2019