Loading...
HomeMy WebLinkAboutSW4191001_17-002 Rev04 2019-10-16 Full_10/29/2019NAN(_LL IU#J I /U,)Ub, I /U,)UJ, I /U.S I U, I n&1 14, 1 ny I I b, 15y I I / ECE GENERAL NOTES GENERAL NOTES 1. EXISTING BOUNDARY AND TOPOGRAPHIC INFORMATION TAKEN FROM SURVEY DATA SUPPLIED BY R. S. JONES AND ASSOCIATES, INC. 2. WORK WITHIN PUBLIC RIGHT-OF-WAYS SHALL BE IN ACCORDANCE WITH ALL FEDERAL, STATE AND LOCAL REQUIREMENTS, NOTIFICATIONS, STANDARDS AND POLICIES. 3. CONTRACTOR SHALL BE RESPONSIBLE FOR TRAFFIC CONTROL MEASURES FOR ALL WORK W/IN PUBLIC R/W PER THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES FOR STREETS AND HIGHWAYS AND THE N.C. SUPPLEMENT TO THE MUTCD AND LOCAL CITY INSPECTORS DIRECTION. 4. ALL CONSTRUCTION SHALL BE PERFORMED IN ACCORDANCE WITH THE PROJECT PLANS AND/OR SPECIFICATIONS, LOCAL STANDARD DETAILS AND CONSTRUCTION STANDARDS, STATE CONSTRUCTION STANDARDS, AND OTHER APPLICABLE CONTRACT DOCUMENTS. 5. CONTRACTOR IS FULLY RESPONSIBLE FOR CONTACTING ALL APPROPRIATE PARTIES AND ASSURING THAT UTILITIES ARE LOCATED PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. CALL NC ONE CALL (PREVIOUSLY ULOCO) AT 1-800-632-4949 FOR UTILITY LOCATING SERVICES 48 HOURS PRIOR TO COMMENCEMENT OF ANY WORK. CONTRACTOR SHALL VERIFY LOCATION AND DEPTH OF ALL EXISTING UTILITIES PRIOR TO CONSTRUCTION. 6. UNDERGROUND UTILITIES SHOWN USING BEST AVAILABLE INFORMATION. ALL LOCATIONS SHALL BE CONSIDERED APPROXIMATE ONLY. THERE MAY BE MORE UNDERGROUND UTILITIES THAN ARE SHOWN HEREON. CONTRACTOR SHALL FIELD LOCATE ALL UTILITIES PRIOR TO ANY EXCAVATIONS. 7. CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL EXISTING UTILITIES TO REMAIN DURING ALL DEMOLITION AND CONSTRUCTION ACTIVITIES. 8. ALL CLEARING, GRUBBING AND UNSUITABLE FILL MATERIAL SHALL BE DISPOSED OF LEGALLY. 9. ALL PAVEMENT, CURB, STORM DRAINAGE PIPE, AND STRUCTURES TO BE REMOVED SHALL BE HAULED OFFSITE AND DISPOSED OF LEGALLY. 10. SIGNAGE SHALL BE LOCATED AS SHOWN. SIGNAGE SHALL BE CONSTRUCTED IN ACCORDANCE WITH LOCAL STANDARDS. 11. SITE LIGHTING SHALL AS SHOWN, AND SHALL BE SUFFICIENT TO PROPERLY ILLUMINATE THE SITE IN ACCORDANCE WITH LOCAL STANDARDS. 12. LANDSCAPING SHALL BE INSTALLED IN THE PROVIDED YARDS, IN ACCORDANCE WITH LOCAL STANDARDS. 13. NO SIGHT OBSTRUCTING OR PARTIALLY OBSTRUCTING WALL, FENCE, FOLIAGE, BERMING, PARKED VEHICLES OR SIGNS BETWEEN THE HEIGHT OF TWENTY-FOUR (24) INCHES AND EIGHT (8) FEET ABOVE THE CURB LINE ELEVATION, OR NEAREST TRAVELED WAY IF NO CURBING EXISTS, SHALL BE PLACED WITHIN A SIGHT TRIANGLE OF A PUBLIC STREET, PRIVATE STREET OR DRIVEWAY CONTAINED ON THE PROPERTY OR ON AN ADJOINING PROPERTY. CONTRACTOR SHALL NOT MAKE ANY MODIFICATIONS TO THE APPROVED DRAWINGS WITHOUT PRIOR APPROVAL OF BOTH THE DESIGN ENGINEER AND LOCAL INSPECTOR. GRADING & STORM DRAINAGE NOTES: 1. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE LOCAL CONSTRUCTION STANDARDS, SPECIFICATIONS, AND PROCEDURES AND THE NCDENR'S SEDIMENTATION AND EROSION CONTROL STANDARDS, SPECS., AND PROCEDURES. 2. CONTRACTOR SHALL VERIFY THAT ALL APPLICABLE STATE AND LOCAL PERMITS REQUIRED FOR THE COMMENCEMENT OF GRADING OPERATIONS HAVE BEEN OBTAINED PRIOR TO START OF GRADING. 3. CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFICATION OF ALL EXISTING UTILITIES PRIOR TO THE BEGINNING OF DEMOLITION AND/OR CONSTRUCTION. 4. CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL EXISTING UTILITIES TO REMAIN DURING ALL CONSTRUCTION ACTIVITIES. 5. ALL STORMWATER MANAGEMENT FACILITIES SHALL BE DESIGNED AND CONSTRUCTED TO MEET ALL STATE AND LOCAL REQUIREMENTS, INCLUDING THE STATE STANDARDS FOR WATER QUALITY AND DETENTION FACILITIES (CURRENT EDITION). 6. EROSION CONTROL IS PERFORMANCE BASED. EROSION CONTROL MEASURES SHALL BE PROVIDED PER THE EROSION CONTROL PLAN AND AS NEEDED TO PROTECT ADJACENT PROPERTIES. 7. CONTRACTOR SHALL PROVIDE ALL STAKING, FLAGGING AND/OR FENCING NECESSARY TO PROVIDE PROPER PROTECTION OF THE STREAM BUFFER. BRANDYWINE DR �o F 4 � O,Q QOi SITE �c ,y wy sg VICINITY MAP i"=2,000' PRELIMINARY SUBDIVISION PLAN FOR. 1_ N ID N 1,R- IIA-il IIA-il U 13 ID I,- V IS.- IS.- 0 N PROPERTY LINE EASEMENT SETBACK RIGHT-OF-WAY CENTERLINES CURB & GUTTER EDGE OF PAVEMENT SIDEWALK CREEK STRUCTURE NO. CATCH BASIN YARD INLET STORM DRAINAGE JUNCTION BOX CURB INLET SANITARY SEWER MANHOLE SANITARY SEWER CLEANOUT METER BOX VALVE FIRE HYDRANT FIRE DEPARTMENT CONNECTION LIGHT POLE UTILITY POLE AND GUY WIRE CABLE TV LINE ELECTRIC FIBER OPTIC CABLE GAS LINE OVERHEAD UTILITY LINE SANITARY SEWER STORM DRAIN PIPE TELEPHONE WATER LINE GRADE CONTOUR FINISHED GRADE SPOT ELEVATION CLEARING LIMIT/TREE LINE LIMITS OF DISTURBANCE DITCH OR SWALE FLOWLINE TREE PROTECTION FENCE SILT FENCE FENCE RIP RAP APRON CHECK DAM OR COIR WATTLE SEDIMENT FENCE OUTLET INLET PROTECTION ELECTRICAL TRANSFORMER LEGEND NEW E FO G- OH SD T w 400 356.44 SF SF SF Fol EXISTING XFO XG XOH xsS XSD XT xw x 356.44 EIP EXISTING IRON PIPE Q EIR EXISTING IRON ROD IPS IRON PIPE SET PKS PK NAIL SET X ❑T CP COMPUTED POINT 0 It �1: I "Iffill) llll� "I - I'll 4i )� " ( NMI INUM RMNIVER HL 1111 000 0\ ls) RUN& wo LE CAP PROJECT INFORMATION: OWNER/DEVELOPER: ROBERT M. BRAME 2863 SOUTH JIM MINOR RD MEBANE, NC 27302 PROPERTIES INCLUDED IN PROJECT: 2679 JIM MINOR ROAD 2689 JIM MINOR ROAD PIN# 9802-59-3969 PIN# 9802-59-3974 PARCEL ID# 170308 PARCEL ID# 170309 TAX ID# 9-13-183 TAX ID# 9-13-184 2.8 ACRES 3.3 ACRES 2863 JIM MINOR ROAD 2817 JIM MINOR ROAD PIN# 9802-59-5721 PIN# 9802-59-4690 PARCEL ID# 170310 PARCEL ID# 159117 TAX ID# 9-13-185 TAX ID# 9-13-5 1.68 ACRES 14.25 ACRES CULBERSON LN S JIM MINOR ROAD PIN# 9802-58-4657 PIN# 9802-58-9583 PARCEL ID# 159114 PARCEL ID# 159116 TAX ID# 9-13-4A TAX ID# 9-13-4 6.01 ACRES 13.71 ACRES TOWNSHIP 9: THOMPSON DEED/PLAT REFERENCES: DB: 2823 PG: 0093 PB: 073 PG: 0293 DB: 3239 PG: 0957 DB: 2487 PG: 215 PB: 073 PG: 0293 SOILS: CnB2, CnC2, CnD2, CnE2 = CULLEN CLAY LOAM = GROUP C RvA = RIVERVIEW LOAM = HYDROLOGIC GROUP B WtB = WYNOTT-ENON COMPLEX = HYDROLOGIC GROUP C FEMA MAP #3710980200 K, EFFECTIVE 11/17/2017 FLOOD HAZARDS PRESENT TOTAL ACREAGE: 41.74 ACRES BY SURVEY TOTAL # PROPOSED LOTS: 33 LOTS AVERAGE LOT SIZE: 0.49 ACRES (NOT INCLUDING LOT #33) TOTAL OPEN SPACE: 532,630 SF OR 12.23 ACRES WINDING CREEK TRAIL: 316.09 LF FOREST CREEK LANE: 1,186.86 LF PRIVATE DRIVE: 1,257.87 LF (IN EASEMENT) 17-002 Project Name (10/17/2019) Existing Proposed Gross Land Area (GLA): 1,818,140 1,818,140 Project Area: (GLA-surface water) 1,599,584 1,599,584 Impervious Area (site) Roof 992 0 Roadway 0 50,518 Parking/Driveway 9,212 2,581 Sidewalk 0 180 Impervious Area (lots 1-32) Roof each lot = 2,000 Driveway each lot = 1,000 Sidewalk, patio & hardscape each lot = 500 Lot allowance each lot = 1,000 Impervious per lot each lot = 4,500 Total impervious for all lots 32 lots = 144,000 Impervious Area (lot 33) Driveway 16,491 Future Roadway 20,000 Future Development 60,009 Total Lot 33 Build Out 96,500 Pervious Area Landscaping / Other Pervious 1,589,380 1,305,805 Surface Water 218,556 218,556 Protected Forest 0 0 Other Areas Custom Land Cover 0 0 Land Taken Up by SCM 0 0 Total All Areas: 1,818,140 1,818,140 Total Impervious Area: 10,204 293,779 Total Impervious % of GLA 0.56% 16.16% Total Impervious % of Project Area 0.64% 18.37% n\A/NIFD- ROBERT M. BRAME 2863 SOUTH JIM MINOR ROAD MEBANE, NC 27302 PHONE: 919-260-7906 BOB@HOLOQUEST.ORG ENGINEER: CHARLES P. KOCH P.E. EARTHCENTRIC ENGINEERING, INC. 204 WEST CLAY STREET MEBANE, NC 27302 PHONE: (919) 563-9041 FAX: (919) 304-3234 P H I L. K OCH @EAR TH CEN TR I C. COM SURVEYOR: ROBERTS. JONES (L-3939) R.S. JONES & ASSOCIATES, INC. (C- 2565) 201 WEST CLAY STREET MEBANE, NC 27302 PHONE: 919-563-3623 FAX: 919-563-0086 B OB B YJ@R SJON ESAN D ASSOCI ATES. COM INDEX OF DRAWINGS: C1.0 COVER SHEET C2.0 EXISTING CONDITIONS & DEMOLITION PLAN C3.0 SITE PLAN (80 SCALE) C3.1 SITE PLAN (60 SCALE) C4.0 EROSION & SEDIMENT CONTROL PLAN: INITIAL C4.1 EROSION & SEDIMENT CONTROL PLAN: FINAL C5.0 GRADING & STORM DRAINAGE PLAN C6.0 UTILITY PLAN (80 SCALE) P1.0 WINDING CREEK PLAN & PROFILE P2.0 FOREST CREEK PLAN & PROFILE P3.0 OFF -SITE WATER PLAN & PROFILE D1.0 NCG01 GROUND STABILIZATION AND MATERIALS HANDLING D1.1 NCG01 SELF -INSPECTION, RECORDKEEPING AND REPORTING D1.2 EROSION CONTROL DETAILS D1.3 EROSION CONTROL DETAILS D1.4 EROSION CONTROL DETAILS D2.0 UTILITY DETAILS, WATER D3.0 STORM DRAINAGE DETAILS D4.0 SITE AND PAVING DETAILS CALL BEFORE YOU DIG... IT'S THE LAW. CALL N.C. ONE-CALL(1-800-632-4949) FOR LOCATION OF UNDERGROUND UTILITIES AT LEAST 2 WORKING DAYS PRIOR TO BEGINNING GRADING OR TRENCHING. NORTH CAROLINA GENERAL STATUTE 87-102 APPROVAL STAMP w U L Cz W E 0 U U U T L LU N M CN r2o O U coLa) N ' N O YU cz Z T T Cz C Cz .. J N20-LLLU W W V L IRT Ir LU CCV LU C* zw Z LLI Z Z J Q = 0-U U Z_ � J I _ CL J z O z LU 12�1 LU O OO O 0O z U IL ovc�O� U) o00 c oc LU LU LU oc LU 0 D_ oc LU D_ rn rn rn � LLB o 0 0 0 � N N - CV - N Q 00 CR 0 CD 0 0 LLI r N C0 � CC DATE: AUGUST 29, 2018 HORIZONTAL SCALE: 1"=150' VERTICAL SCALE: N/A PROJECT MANAGER: CPK DRAWN BY: CPK PROJECT NO: 17-002 DRAWING NAME: 17-002 REVIEW THIS DRAWING AND THE DESIGN HEREON ARE THE PROPERTY OF EarthCentric Engineering, Inc. THE INFORMATION ON THIS DRAWING IS NOT FOR USE ON ANY OTHER SITE OR PROJECT. THE REPRODUCTION OR OTHER USE OF THIS DRAWING IN WHOLE OR IN PART, WITHOUT WRITTEN CONSENT OF EarthCentric Engineering, Inc., IS PROHIBITED. COPYRIGHT 2019 EarthCentric Engineering, Inc. SHEET NO. P:\17-002\17-002 Drawings\6. Rev04\17-002 Review.dwg, C1.0 - Cover, 10/17/2019 11:54:04 AM PRELIMINARY SUBDIVISION PLAN FAKI LL IU#J I /U,)Ub, I /U,)U'J, I /U.) I U, I n&1 14, 1 ny I I b, 15y I I / N u �14 �Y Sg VICINITY MAP i"=2,000' PROJECT INFORMATION: OWNER/DEVELOPER: ROBERT M. BRAME 2863 SOUTH JIM MINOR RD MEBANE, NC 27302 PROPERTIES INCLUDED IN PROJECT: 2679 JIM MINOR ROAD 2689 JIM MINOR ROAD PIN# 9802-59-3969 PIN# 9802-59-3974 PARCEL ID# 170308 PARCEL ID# 170309 TAX ID# 9-13-183 TAX ID# 9-13-184 2.8 ACRES 3.3 ACRES 2863 JIM MINOR ROAD PIN# 9802-59-5721 PARCEL ID# 170310 TAX ID# 9-13-185 1.68 ACRES CULBERSON LN PIN# 9802-58-4657 PARCEL ID# 159114 TAX ID# 9-13-4A 6.01 ACRES TOWNSHIP 9: THOMPSON DEED/PLAT REFERENCES: DB: 2823 PG: 0093 PB DB: 3239 PG: 0957 DB: 2487 PG: 215 PB BRANDYWINE DR �i� ,0�2� op \VA \ \ �� �� /// /����__ \\�V�\\V V\ \VA\ i_ i (�_/ 1 �' / A\ �: /��ii7-= %��/i// // V v v-- OS \ // /// / \\ \ \ \ \ \ - / / p _� i i-/ - - - // / I \ \ \ �� l«oz) se ava-arar� �nr \ ) V A V - / / �/ /� - \VA V� VA ���\ \ �A \ = - - / - / v - 1 / + -5° + / - _ _ �7 _ —5 �= _ -� �i//i / _ _- — - �� l/ T 1 / / \ V A \ A i / v � �iii - - - / I I \\ \ / ////h.�/� // / -� \\\ VA \�� A� \ VA�OS�. i - / - �500= i�i��- - _5�° j// 1y� // / / A - ///// /Z S v VVA A V A\\ \ -- - - �� / /�� �� - �i/ ���- hti / \ v \ a \ /� /�o /_/ - �� \ \XVA V�\ V/ ��AA \ �A - 500� + + + \ '+ �+ -- _i �/ �� _ - - - - /-� A \ �I v /- ' / /// / / / / - A \ ��� �- �/ i// '%i / - ----- �__ A- --- \ \ V I I I I I I \ - / /j/ // / / �v vvvozvvv A\\ \V\ /�////�° /i / - - - - V \ \ I I \ -- - - - - - _ / i� // f/ / / - vv v wv v�\\�VV A / / '� // / i'i/'//5 5 �' - - - ,52a _ - - - sos_ / /// ////// / / / - - - � v VA A VA \y \ \ \ -, / /of \ � \ �\ \ (+ � I V / / / ///� //// / / --520- r � - - V A \I I \ V - _ _ — _ /i %/%//�/� i / vv\ v VA �\ \ \ \ / / //i �� \� /� / __ � - I / / /// /�v�v v \ V AVA\\ \ \ // o \ �� // /� / / - \ \ \ ) v-- / __ / //�/ / / \VAVA\\VA / /i_✓/ U� \��\ oA 1 /II///( //�/// - / _----_ \ V A \ II \ \ \ v / // / / /f / --_ '0 vvv\\\VA \\ \\ \V� _ "\°o C �� i / \�\ �� ---- / / --- \ V A \ V \AA\ v //� — �� V /////�//�///// - vFs. AVA \\Vv v s � �/// I, I A\\ +II ////' / v /-v v// //- _ \ I \\\ \ --- A \ / / // ///// / / / / --- AVA\ \\VA \\ \\ \\\ \vv v / / / / / / -- / // r \ + + \ �I I I I I I \ _ -_ // / \ \ \ \ l \ ", ---_ v / V \ \ v / \ \ \ \ o1s- / i - _ / \ \ \ \ s v v/ '_ / - / (� v o / - V A I \ _ T, / // // / / / / \ \ \ \\ \ \ \V \ vv v ��o� v \ / // �5� / / i� I I I _ �515 - v v \ \ V A \\ \ \ \ / / / // / v V� \ \ \ - - -v // /-----� \ V \ \suet/ A �A V \ v-�/ �-- - v /� // / / / / V N �� v s %� �/ / / / 1 � 1 \ o; .I �I � II ��- / / / / V A \ s+ VA V A \\\ i// -1 V�ot9 // //Ill// I ll \/ /-� VAV \ \\\ \\V��A�\�`\� �i/_ �' // //+//-/i��\1 . I /� -_ / / / VA V A \ I\ \�A VVA \ \ Vv - // -sss \\A �' /// / �I / v \ V� VA\ vv-_ --// / / /d / / �I \ - - // / --= \ \ 1 \\\ \ -_ �( /1 \ A \VA\�v��v��- %//crime- / /� /�Z A11\\) I)/� v \ / --__ / \ \ 1 vv�-- /� v A ) -v v \ V /vvv vvv v vv v v� -_ //�•�/ )/ / // I / // / / - / t \ \ \ \ A \\ �I \ s�vv vv vim--- _- __/ / s\ \4- �I wI, - -- /----- \\\\s/ \ \\s \ -_- / / 1 \ - \ \ c \ \ \\ - - - // /5A5 / / +% \� \\ \\\\ o \ / // / / - / —o of 1 V \ /// /-vvV�\- 1111 II o A A v vvvvvv vvv`---- �%//��/ / V11 // / / V'� �\\VAA VA\ w�N�r� I / // /� --__ // // / oas \ v J 1 I I M I \ v v v vv _- - - / / V /+ + +)A \\ \ �\ \V\ rn rn / / // / / / / — ors / / - - eon I / v/� A I �I \ s� v vvv\vvvv v\��- - _ / / \VA \VI( ti / V�. A v \vVAA VAY����� / /� � � // � l 11 I l I I I ) I I \ //// /v --v )V \ s � vvvv vvv ovz = // / / ��1� cL \ VA\� c� o o / / / --_ w / / / v v v �s / � + \ + \\ \ \ // / // v / I I /// v A� \ I I � I 1 v v �_ ; // + \ 1 I V o / I I / I v �/ / v v� _ A \ / IIII I I \ , � � _v�vvvv�v _ � �� � � - / - / � � ) l I I of I \ �v \\ \�vV\ �w � N �r � Q= - %�� /=/ /> //,X / � / I I (� \ i� \ - \\V A\ v v v o I v A �\\VAS = m o //_ / //`'� \ VI�\ \ �' " I / I / \ -///// /�� ) \ /)11NI11 Sss v v v" v / 20 III o I �\ \\' ' v�vv,�� mm�—= / i/// // / / /� A \ \ V U - i -- A / /u� / �G\ .\ _ Q Q�� _ -- �i / /� � � \ VA I I I I / I I I cS\ i // 1 _ A V A \ — %� / I I I I ) / \ \\\�S \ \ \ V \ \ � % U I I I I U' �-.•. A\ �\ / / / — \ I \ \ I / / / \ \� // Z - v - I l / v � v �v v �-/ //i vv �----- _ / -_v __l �( \ 1 / /// -��\/ A \ // �/ / /- vv v //- /� � 7\'\+��\ v \� �//� - v l / 1 I / ) / / A -� / // / z / \ \ V A \� V I / / / Sao- v v vv vvvv vvv v\ - t / r + _ A+ . v v _ / I I I II /// / / / A � I I / I // \vvv vv \ )I 1/I II / o vvv -__-__ - - v l / I \ / // \ \ \ -_ vv vv v v� sz __ - -� I I I o o s V' �� ovv 5°===� �� ���--_� / j /I I//// / / / v/ /// �// v �I _ A \ \v vv vvvv\_ vv�� �I �I I I o + +.off+\ V I �+ sv \ _ __— soo � +___+ _+_ // / / // /// / �llll ��,- illll ) ) v\ vv y\ vv " \ �) to IIII �I + r � , / / / / / /I I vvv/ v vvvv vv, - v �� � �vI + v+� _ = _ _ s / / // / / _v\V A \\ \ vvv �/ \\���� z 49 — sstiv v�o� / /// ///�l) / �/ I� v / / tip/ - - v- A \\� \ �V A \ \ �v vv A 0 II wQ,( 1 I + -k + +y + , /z - 5 �+ - �+ ,� vvv\ � / / / / /) �' / /� // / v / I�/III 5/ / -_ v V A V A \ \� \ \ \�� vv v - \ zCn )) \��� A v / - \ v v / / / // / \ v / 5� / - / v_ \VA \\ \ V Av \ V � vvv V A ��� V A V AwN \ I + + + +. +' v+ +o //-f � � �- +\ + + vv' �/ �h// ( / / v � / / - v v _� \ \ \ / /ai \ / / (I / / \ / / \ \ v v vv A \ \ ' \ \ \ \\ Q + + - +\ + + I Io �,' - V /�/A \�1 / ) / / �� / / v v V A \\��-� \ �/ A \ rnvA w�A\ \ \ \ \ l I / �/i _ ' � / / / l �/ /5 v v� \ \-�oF�vA vvAV�A \ v� A V Iern �� vvA\ \w VAv �V / +� + + +V / \ I — / f / 2 / A \ S \VA V ( \ /\ F �S \ \ �lf)� Nam\ VA \ -- A a� \ / / / l l ( \ /// \ A / / - - i' - - - v �v \�� \ ��s VA V A / v v v \ V Ai s v \ \ V� Q co N �v vv�\\ c� c°� v\_� Q + + �� _� o= \+ + +• '� +\ 1 + + + / + \ -/ / / V A I I \ \ � / v v Is\ v 1 1 \ � \�s\V A I \ - A \ o0 ��AAV� - �o o �. v �• \ \\+ + + �+ +// / \ V / A (n I w \ \ mA A %/���/� \ —//// 0£S� V ( -- \ \ \ \ \ /�A / ��S V A \ �X \ — \ \\ �A�Np�pO�' VAVA _���—��r�oD' v V / / / //— _- - + + - I• +• � / / /� V A I I A �/ /// / — \ — — / / \ \ — � // / % / / ��\IA V AA / \ V -) \�S� � \ \ \ _� J CO \ �A�V � VAS m �"In Z � I �<- w ) A / / / / / //< ) / �/ v �i/=/ / v ) \ /AVA \ �/ / / / VA\I -) /A VA V���� _ �� �m w=v ozw V� - Leo ow\' // Q� ���� - - �� \ V / / / �) /� - / / / / \ - / \ vQ 0 vvv ��� - w - ��s/ o �' \ 1:. \ / J / / t\ V A \ �, / / \ \ / / / - - / i I \ - �ozs_� w � \ I \ \ _ / - I VA\ ��vv z w \ vvvv - I I + + + V A 1 �+ . + I + + +/ + + / I \ M/ / / / / �/i / A � -v A i - J / I V I I � � � vv\v z - � N a� �\\ vss / / I \ V / ) / / v v A / - // / 1 l -530 — A \ // i - - / ( \IIII �\ ��= svv vv \o w ��I �� Q w _ ��� v��v - z W �-500 I�1 � +.. j + + + / + / /� / / / /) \\ z-I II ly / / I / — — — — b \ vA %� � 0 U U V�� — —� J �_ — ti V✓�— / / / \_-// �- - _ ) / - \n / aSv w;� ��� hoc �� v �. \ / )) / / / \ —/ // / / \— / / — — / I / \ ASS--\ £� \ w m> (n \\\\ — ~ / b ��.k C�� + I +\ +�/ + \ / /// / ////- / / /vvV A/�� - - V I w /� vv _�F �� � �Av --v-�n �o`� I� / / // j l // �r -�� / / - / i V - / / / / v �, z�00 S __ S- ��o z� � �v 3Q- a /// / ) % / - I v / _ -- A / - - V I I � /yam' v vv , � � 00 00 -� j � _� v � �A\\ o_m- � � /� / / i / 1 1 / / / A v - - �\ ' - i - - / /- \ �I �- / v r7 rn o V� �� N co ���\ VA— _ -51 ��S \ �[ A + + / ' �500 + / / / / // / / — V A / l A � — __ V) I 5; f� n N � __ _ 00 V — A /// 11 /I / d/ / //��/ �V \ ��/— ;---A AA\ h��l I / / � S� \ —/ / II� � �/ \ N� w � �, N v \S= — —� \ ) o \� w� +� / / / —t / / / / � f / M �/ \ — = 00 / \\ / / �\ / / I / \ c� � � � � 1 vvvv VAA\�\ / I A � " / � I� w� � / j/ / I I // l 11 S� V / / °ff �� V\ � v - / / / t /// / / l l / l ///� -��� --` vA\ v-_ / - �l w� �) ,�nwN oo�000�_���� sv /� s ���bM3n��a =v\\y� �.I // + \+ l�/ l zrn m06� - / A yo / / // j // / )l /I I I �- //�/ // //o - - �\\\, - /�/ - �/ /// /,� \ / oz "� Div \ \ w\\\ v �- v / // / / / / / / --- / / / / / / / - -� a/ - _� - - -- -- �m ww_-- n A\\ \ \ sv� �vv�p- \' I tJ v� +. ( ( + + / / ) //� /// VAV A ��) I I \ l / / / " \ / — / \ 0 \ \ \\ \,w \ \ / - / /i / // / / ( I I / //�/ / \ i/ // -sbs \ \ _ - - - - / �� / v v - / \ V A \ v \ �� I I A \� ' / /`� / v-- vv\ o �-- -�-- -- / h \ -� v/ v\ vvv v\\ \ \ Nv v� ll II I � I w + + / / / I I / / ( / f/ // - -- -/// / \.\ - - / - - - / va A \ \ v A \ VA \ � I 1� \ / / )� /�/i i/��°�/ / /\ �/ A ���//�/// � --obs v-_ / // \\\spy- _ _ /5q0/�; �/, ) �vv� �� \ o v A \�s\\\\ \\V�\ \ �A\\V� ��V v �\ �/I ( \ \\'\ w //� / / / I / / / ) / _� v �� /,�, A\ V A \A \ \\ \\\ + \ :_� IIII I \ + /// // // / / / / i // // _ �/ / A\ -- — — /// / — VA ZN� A \ \\\ \\\ \ VV A\ VA V / / / �i / f // / / / / - / / l J / ��/vv--_ _ - - �i�/ -==� / v-�'a�o0 A //'d- \ \ \ A A L +I \ 'k /// // / / - /i/// / �� \ / v -- _ —9t's; _ _ /� v- -)o v h \V Avv vvvVAVA\A\\VAll ;I / \/ ! +I- I +1 A _� ///�/ / / \ ' / / / / / / / J /--_ = .___ / // \ \-\mNCn� \ /��� \ \ \ III \ i \\\ / / / \ \ / s / - / / / I \ ✓ / - v - � - - - i�1 // � / F� - �--- � v , - _ ,n oo v h \ \ \ \\ \ \ \ V I _��t� - + \ �+ // // / / I V A \ V / V v _ -535. - / / / / - ^ / / - _ - �/ / / �v A \ \ V\ / 7, w, \ / / / / / -� r w sv A V \ VA\ AV� 1 ( �/ J / I�� \ \ �� / / //// / \ sV1 I I v --- // /// / \ / / / / / v _- I /� av w_--- ao ")�vvs - v \ v� A V �\ \\\�'\\\ V A \ I11 / /�/ \ \ �-/ / / \ V - - / \ \ / / 5i / // w \ h � � - oo ov vvv�� \ \ rn - __ / / / \\ \ \ I I / /h/ / // / V / n \ �- o w---_Ornwl�\V AV- ` \ \ \\ \ / / / + / l / / /�- / � /i � 1 s v�� A \ \ \ / / / v / / / \�II I �— ,---/ // ' \ \ \�/ / / v wo /\A \ )� _— ��Um -'7"" �\� --A \-- \\ �VA\V�\\\� \�V AA— \ IIII II I ///// // /+ � \+\ �// /— — _ _ _ - / \ V � V A\V\ Q A\\ b(/ / / \ ///� / \ VA ------- 540 / / / \ \ / / / / / / A / i \ '-/ z'<1' \\ v_ � A A - �r / \ - // /-- .� / A to —� �_a v v vvv v v----� / / \\\�\�� 1 \\V /o \ \\�\\ V I\ \� ((// / / // /� A v / � /// / / ----- . w� �� v v \ / \ A / / / - A \ \v ��\ v A \ \ // / / v-----_ / s� v / / a v l 1 \ \ /_/ - 1 + / / A \ v------ ��sbs - v s J / / / v v v C < > ��� / / 1 V� \� \ VA V�I) II I // + - � + v ///„� // > ri v ----- �- // \ �/ \ V� \ w �_ -9 vv v / ) \\ A v / // - _ _ _ - - v \ / - / / sss w, /i A v v vos� v v v vv \ _� — - vvA - = oss- - -z/ Aol� VA VA�\\\�\\ 1 VA \I I I I I // / / 1��s50— — — ��� v v v / // / / z o�D�==ice v v -vvv �A V ��- vvvvv v\� - -- f � 1 A�\\� ,IAA �VA \ \ IIII l v%+ + ��/�/ ///'�/) //�/�i� /// _ -- _ — V�� '�-- —\ V A / / / // ��w� ///// V A \— AA A \\�\ ��w-�� V� VA A �_ /�// /� VAV� IIII I�`�'\\N I �I AVAAI �II I �/ 1 / ///� ////// ///. -�v � _550-� v v v A / / / � ;°' // -/ v� vA VA Vv\\sVA vvvv v� �-� �sb----- � / -_----v\�v \ V A �V / / / / oo j/ / _�v� VA \ /// / �r� '- v -_ S� //�) A\ \ ��III \\�\III A��VII ��/+ �/ //// /////�/// _ v 1 - � - --_- J v III _ _ -\ \\ \ 1 / I N\\\ I I /I ( / l //) / / / r s / v / / / // �, v \ VA / vvv v_v\ _--- / /\ I 1 / Ijll IIII �+ /��/ /j/ / ,/// /. �-3 A V A I III vvv __��- // �I I I % �) A \ i� // �f - -�--sue v v� v vv / vvvv / / _ �`� � _sss, - \ \ ) 1 / l (�)/��%-_ v v_ _ �� - /�' _ v v v' �v v� -_v _ � / // 5�° /_ .� - //w vv- \\ II I II/ice// h)) ��i� �F _ _obs� _ _ / III �,1 // /M �/ v vsv /�✓ ) v v v / / / �/ vv A �� / � vv �s _--_-./ BUFFER i // f \ V / � V\ v v v� v v - v � vvv vvv vv ����vvv� �C� '�- v �w��� -_ __- I'I / STREAM h // // c - \\ -Mcn �'t__------ / /. / / /o � -� — � \ � \ \ V A \ V� \ � � �/ I — � � A \ \ VA \ \ �A V) � I I I I � \ V I I M / \ \ \�� � 0 � � r� — — _ /� � � // lIl // // /� / � -�I J (I �I \\ II / I III I I II I + II � \ ---v_A v v v vA V A I / v-\ / \V / - \ / A \/ )I I I I I Avvv__ -mom //////J///// //////� �P�, r \\ / 6° \ V VA \ \ \ I I V A �� I I w v £s, . w I _ _ - / /�/� // /o/ / / �/ \ / / / I A - \ v \ \� \ \ \ \ / was \ 5 \ \ \\\ \w \ - --////i/ //h/ _ / \ \ / I / \ \ / 1 V \ \ \ O P / v A v - _-gJI�N�_ - _ - - - - // / /// ///� / // _/ �� \ / ���- v VA V A \ \ V \ / v \ meoo • -- - / / /// // // J 1 A / / v \ \ / = v v v A \ / / ///�/ / /i / / /oi —sss v v \ o \/ \ m� �s V A \ VA \ \ VA \ V I I / / �v �szs - - - Q oo - - - - _ - �/ / /C /, ,o'/ /� �°j / A / / / I +/ /� _� _ - -w o x_ - - -oss �� / / \ \\ \ 9 \ \ \ \ \ \ 1 �� -��o \ \ \\\s\ III 11 T / i m .. - /)l�ji / //� i - \ / )l I V �/ / - - \ v v \ /. v _ 1 � v I / �� /// , v / / /// / -� — v \ \ \ v V A V A v / / v A v m ) / - �w o' — ��� ///�//i v - / - - - w N - -� 0 _---- _-/ii�//�//�/ / i� /// --�- - / / / j/ �- / A \ \ \ - \ V \ III ��_� - A �� �52i/// / /� / �� / / �� � /// _ _ v vA v v v v� v v �s v v __ �s v \ I , , , z -_ - ----- / .� / s v V A \ 0/ ) A \) I I I to ��--- vvs� ---- //���///.� /� // / �� //V �/ /_—= \ \ \ \ V A \ \ \ V \ Iz / h \ \ \ v v - - - / �O / / �/r / / / - / //o / f// - \ \ ) \ \\ V \ -_- __sI ,5// /o / / //ice /- o v A \ v � = ) \ / V AVA \ \\\ \ \ C-o �s� v -- - - -�� iii �/F j / S / / //� / - -v V A \- _ // /� o \\\V A \ V v v \ \ \\s\ \VAA\\ \A�\\\VA\ \ �- �vvv� ----� --�// / /; O / +-� - //// /// ��515- \ ) \ \ w / \ \ \ / I \ _ \\ � -_ � — - - -/_ Xl i< I �o I I O• % / / / /// // _ \ 2s,� / /// // / , / /� / - /�-- V A \ I V\A \ \ v a� �, ) / v v \ V V / VA VA \ \\\ �VA\�\ V �\ \ \ �� v �� -- m s v \ \ \ \ \\ Vc-moo - --- _� i- Ei/��% /� / / // /// \�v / % j/%/�- / \\ \ \ \\\ \ - / - / / P �/ / / v v \/i, // // / // / V A V / / — \ \ / / / \ \ \ \ \ S AAA _-- 1° /ii t� O \ O/ / i // \VA \\\ �/ / \ \ w - - v v V A v - I I \ \\A\ \ A� \ \ \ / - / / /o°�//// / // // �- / \ \ s \V A\\\ \ VA\\\r \\ \ �5 �o // oa / / �� �� w v _ / // / . I � I I I I \ v � v 1 ( / v v V A v v v V A �A /A A \ �,��\V �V A /�j /// / p / F,�`' / +� / // j / //// ��' / f // / \ - ,ao i / / / - v - \\V A \ �� AA\ \ \ _ — ��'� _�=//% F`� / // // /_ �_v: svv vv / /�/ // %/�// / / / \ \ - �, \ / stir- \\ \ \ sss \ HATCHES AREAS \\ \ \\ \ \\\ �\ \ \\ )_ ; / /// / c, / / / ///// / - \\\\sov \\� - //�/j � // \ ° v \ / / v vv v - v v / / / / NAicATE suiTAB�E \ b\\V \ V AVA\ \\ \ - - - � /// �/ �� / / i / �� // - vvvvv �j/ // / / /, \� 1 V� \\V \\\\V� // �v v / /� / / / - Q - \ / _ v - \,� \ o - - / / / �� / / l// // / //// / vv �� �� / /ii// / / I l I \ v . m � / - - \ v v / \ \ s \ \ �\ VA \ = s = _ ��� / - P / /i / _vvvv��� _ - , �_// - // / / /� \ w �- \ \ \ I / - \ sons FOR sEPTic \ \\\ \ \ \ \\\ \\ \ \ \\ \ // //�////// /�/// / //_ \ _\\_ ;�--/// / o� / - \ \� a A \ - v v��-_ °ssLvv - / \ vv -- _%�/ / v v �i - _ , - _ _ v v v I I I �, v - i �/ / /// / // / vvv= °�s_ _ �// // ,� /� /,I / . /// / / v - _ - � // / , w oo \ - / / V AV A l� o /��v _ / �/ ///// ) / / oc .� \ / - - - v - v\ v / / 1)1) as5 + / // / /l 1" / ll / l l l l / s2o� „�—_sss== - _/ = i w / \ VA v / / I III IIII I IIII I v',- /.• / / / / // l� lI \/l l/l / - �� //ice/_ / / / m �o �. �� / I / / t /��o — /v v ss\ vv v� v / ' / / I l , I I I I I 1 / / / / / �/l / 11//mil / _ � _ ._ / //%i \ / TERMINATION POINT OF / / / / �� • ' . J * - / J / / / / - - - \ �� \ \ V _ V - � / I I IIII I A / / / � � - - - _ - I w I A / ///"� / / / / / I I I I / - �525 _ / / v \ \v v v-//// / ExISTING 8' / / / / o�� oo'�� �' ��_ / 1 ) / / /-- vvv\ vvv v v vv vv vv l I) I1111 ( �.� '/ // /� ///%raj/�/,Ill / / I ICI I I I ) / — --_ ; �a�% - v v-_ // � o.� I / II �� �I ) / / I - �- -5// _ i / i / / / / 555 I / / - v v V A V A \ / / / - / / / V A v / - ORANGE-ALAMANCE PUBLIC /. pR /� - / v� v v ° N I 1 / / //� //) / // I - %/ / / / v - - / / WATER MAIN (PER / /��`��21�� ��� /�G� / / / / - - / / vv_ v v v v !� \ \ \�' I I %K\ o� / �� / / �) \ f / v v v ��/ , R ( \- v v v\ v v � w �� � / � •' / � / I( I I I I I I I I/ A �,r- �// V -�565 / ORANGE-ALAMANCE). FIELD \ S• 5�' ��G G / / / - / / / / - _ v\VA as v v v v v v m X ) \ V '- V v A )I \�,A\) I ILL / ° I. �/ / / / \ I \ / v v v� _ /i VERIFY PRIOR TO START OF a P�� \ ��� JJJ��� - / / - V v vv v v� v Y a / '� \ VA VAA V V AVA VA Vos Yl�, ,P. I- / /�) I I I \III A V A \ \ --- - / � �<1 60 \ p0 I `I / y / / / / / / I.) \ \ \ \ \ U / / \ \ \\ \ \ \\ \I 0o2 ) \ \ - CONSTRUCTION. �, w � I - \ v v o z \\ V AVA\ +/ / o N o (( ) A V A v // - v �E�v ����' \ / / - / I / //-- v /� v v vvv v v wQ / \V AA\\ VA�vvvv \v)A\ \\v \' \11 /� P�• \ / � I M� \\ 111 1 I I V�\ \ \ V v vv I l / �' - v `s v - V / / / / � / v v "I v v v vvvv vv / I .// �/ w I 1 \ \ / _ 535 v _ — '/ �/ / ,a ��v \ \ t / / / 55 / / / �/ v v v v v ) v\ A\v vvv vvvsuevvv v \\\ \� �/ \ w�,�o A \V\ \ \ v s�v \ / /f vv------- v V m A v vA) .I . (:/ / - / I I „'/ � _ //// v v v vvv wvv vs vvv \ \\II -) \ 0) > - / / / / / \ v \v vvvv v v vv v \ V A) i 1 I Q / + / // )) I V A \ \VA� -_ � � s \ A \ / � /� �� - \ A ) / / v A\ v vv \ / N // - - - - - v moo' ��'� \ v v A � - / I ( / �� �� v v vv v vs� - / v v \v\ v�ovvv vv vvv \ \V /� II / 1: \ 0 -' �' 1 /ll / // /�/ A \/v v\v v v \ VA I ( I / � / / _ _ — — — ' 00 \ . — A \ S9S \ \ \ V / — I I I _ A \ V A I A i / V A \\ �'S VA\ \ V �VAV `�i II Z o, c� / / A \ - - A v v / V vvv \\� \\\� I / \ 00 w rn / // / I \ w - 0 V \ \ \ \ / / - ��+ \ V A \� y .Sg V / - ) I I 11d� vvv A v v v % - -� v v \vvvvvv \ vv �w AVA A\_ �� p' I (� V -> � �I I // / /// / / r \ vv v°zsv vA \�A VAA \ \� / / / v \ / M v vv v Qzo \1 ((o / )) \ \ vv v \ \ \ \ vv v\ \ \ vv �l/ v v v / /�_- �- / �/ v vv v v v v vvv ( w �� // - v\ - _ Avv v vvvvv/\\ / / / vv v vv v / /-- --- , _— -� .� �Q� \ v \ss \ // - � \ I / / jll /- \v v_ v v - era \ v v �w vv�� V A �� A� z_c�- �� / v v A / oc m A �. // - u)� V AVAVA\)))� �A v / s� v AV \Vovvv / // �.Qiw .� E \ V A \ �� ss \ VA\sVA �� / a /� I I /// \ \ \AA- AA AA \ - - �a �� I vvvv �wv\\VA V \\V�l \\ _ ----_ �A\ \\' II // A s vvvv v�\ \Fs � �// ////= --- v vm \ \ w \ \ l �. A\ V\V ) \ \ V �n �� j m� / // /o// )l l/// //// l \ V - vvv vv v v- _-- ��m °'� w vvA\VAA�1��� v��V /--vvvv�AVAIII�III �I �� ����AAvV//�/�� Q N \\ \ v - \ w r7 \\ - 52 - -; vv ---/ /// \ \ w� / a //// // --\ - w v w�0o� \vv A \��- / � - \ � ��- _ � \ / I A \V A \ N w / / 4 / // / / / \ v vA I � \ V wvw - �� A - \\\\ - ; v v vv v v v � �/ ///- `° Q / \ \ \ Y w / / / // / v v v v sF v vvA \ V A \\VA\VA \ \ v / _ oc - / / / / // / / \ _ - s - ,� �n rn N a,. AvA\\\� �h A \ \ \ V A / -- - --ots - _ =Avvv v v _ - � / // / / v - _)r)o.. v v� h\� \ v --- \\�\ V ------- oo r7 ? % 1 A Qv A \V�\V \\w� / oo�v- / /// /////// //i/�vA�- �) vv �o'N000A 540 �� VAvvv�/\vA �.�� �,----��� vvv ���- - / V "- Cn rn warn \ warms / - \\\\ \ / //�// % W w�N / NI r/ A �\o�, 0 2� V A—/ / // / �// y�\\ —� — ��Hr7�— \ —� —�A VA i—III \V�S \ \�� A V A\V A— �/ / _ —=_VA\���� —=52i/ / /% — — -T E� < Y _ / w \� Z N ) A \ V A '`\ \ U w m \ v) - � _/i /////// %/ / �/ A , — �S�av v �� — — _ v w m z X` V A — A� A SVA� — \\VA\V �A\ �b \ \\\� \ \\\ \\ / j // �— —905= ���� �� ������� _ _ _ `21/ / / / w � / O W V) w �� V A _ // / /�/// // // / � \ _ `O� \ �_ — — — — V .— i ��� �� �515— / / \ / \ ° � , / / / /� / _ v A v v v /STREAM \ \ . v v - / \ �� - - /�� , / to _ / / \ � \ p m o-Q v A V A \\ V v V \\\ \ \V� /// _ _ A�_�� ��� _= 52 - / / w " w�rn ®�21� war' 4z. 14 / % \ \ w f / - \V\ rs� v O w� V 1 1 / ,D,- \V A \ \v� \ VA\VA\\ / / �/� / N / U w ) ) Q. Q vi \ \ /m \I I I / /// // / / - 1 _ - \\ \ s \ \ \\\ \\ \BUFFER \ \\ \\ s\� \� 5 - -- _ _ - _ -�_ — 510- / l / / ii _-_ b \ w w� / w / / p- w / / Q \ \ \ \� \\\_ _oc- //� / /// // // Q �- _ \\\ \ �\ \ \\ \ \ I I\ \\\ \ \\\\s\\ \\ \ \�\\\- \ 09�/ / / // /9`�� �_ �__ _ _ _/--- w \ \\\x /// /// m w _---- \\ \\ \ \\ \ \ \ \ \ / // / - ==500 =�j j ®wQ") / m / m /� Q� / " r7 \ \ \ s\\ �\ <N� oo// / // // / w �v v _ vvv v vv \\� A VI 7A\\ V AVA \� \\\VAV� \ V AA \ )// // II IIII / / // / %/ ���, —% +� \ z / U / / L Q,1 A \ \ V AV \ \ / \) - - -�� ��� �- v v v v A \) V v�\ A\ �V / / / / //� /// //°� - _ -as5_ Uwm/ / / / w�N \\ �\ \ \\ \ ��// / // ) �- \s\ \s \\ \ \ �\\\ \ \�--\\\ \ \ \\ \\\\\ < / // 09 _ - �- v � / / � v \ \V v\ \ \\ 1�� /i / /� �vvV ��N-vvv-v�V`� - v vv Ao v v --�\\ VAw�\\\VA�\ VA \\\� V v III II / /// /j// ///�/ _ =aso w w / �/ / / Yww \ V A \VA \ ��� (/\ 1-_vv� �Cn\ ��vv vvv � F \\\v - A \ \I\ \\ \ / --- -- v 1 m ��� ��, �, �w V) v� v v vI vvAv \vv 1, , / - _ _ vv N v v w vv , ; vs v v v ; vv - /v vv v v vv vvv vv v v v //// / // - , Q\ / Q Z 5' / 0_2 \ \ V A \\ I /// N I — —_-- V'W 0] I A VV�VA_ �� A \ ZS \ VA VA VA S �� LL / /) \\\\\ VA\\V�\\I� \�\\ \ V\ \ I A I II II /// /// //// / / — — - I- — � — V I V m \ /� Q / / / / /�� / / / / / �55 -U w �, I / % \ \ \ V A I / h < \ A v v v A v v v - / / //) A� \\ A V A\ \ V A \ \\ V �I I \ \ / / /// // // / - - - - �w m / �'���"/ \ / ////�///\\)A) �I/' I//V �_ - v s V vo v��� vAvv v v v �� v / /1�11\ \\\ \�1A\�\\ \ \ \ V / \\1 I �II �1\� i / / / �i \ 575- A / / / / �� - - / �/ a - �� A A S7 \ \ \V A V A �v v V v V A �// / / I\\ \\\ III VA \ \ / /// // / // / / / _ \ - Q Q I - - \ V O V AA \ V A - - - - \ A v - ( Q w / / h / / ) \ - v �v v v �s vv sss- /h/ / /// / / . A / m / v v\_ vvv v v v� - \ h // / / �/ / / \ 00 A / / - V A \ v vv _ - - // / h / \ �� o v v\ _ -- �\ I Oo / ) ( � � —' / / // / I II �;;�� v� vvvvvv vvv\vv ^� ��� �����- _ v � ����-__ _ i Ali //���/// / / Iv m v \ z Q / -' / /' �C/ / /i / /ice// l/ I I v v v v v vvv v v \ 1 / - vv\ v � ozs_ - - --��s_ / /// // /I I III III IIII I I \ v v VAo" . /i�i� /i/ / / / / / // / / /// _ \\ \ \ �o�;��, \\ \ \ ) I / U I \ \ ~ / // // �/i \-�_--,Fs. \\ \ \ \\\\ 1 \ _____- __-/�///� II11 \ \\ \_ /i/i �i / -- /i / _ / \ \ \ O�NN) A V \ \ I / / / // / — \ \� \ \ V \��W \ \ �� ---- — // \ \ \ \ \ \ - _ \ _- -sas — — - _//// /% 11 II ICI I / /i / o� A V A \ \ } Q �i / / �Q / ( /� v A V / / / \ \ aNr7(r \ \N / / to O \ \ 0 \ems _— \ \ \\ \� \ \\\ \ \ !� \ \— -- _ _ — -- _ �, n \ \ j // / � _- / \ 3 w \ \ 1 ) / ) I A / / m \ V �A / A\ V A%V v v v �/_ /// / b 1 °° A� \ // / s 5 / / \ o .. \ \ w / / / � � I I \ % ' v�\ \ \ \ \ \ AM BUFFER \y v A - - //� I I \ / / / \ v � v���� � v� � /_ )I I I ICI I � \ / / / / \ \ ono \ l / / / \ I I W ----- \ \ \ \\ \ \ 'TRE _� ;;,; — _ — _— - /5 ! /%h)JI I �I\I\� \\sss /� / / --- / / - �_£S�� � —520— = 1 / / // oh / \ i // / / / / r i i / �� - --- ii %�/ l / V / / / / / �v `.zm�-1 , w / � �� / , / / ��� / / I A II'v__ vA v v� v\vA>v) v / /�� �-•-� — � -_ __ _=__— —,5,, / -%/�/ / / ,/ �� `v / - ) �' // _ \ Z X ro / / rD / % \ � A - A \ / /. / -�� -_ lS� �V - / / / / ' \\ \ g0�j / / // / / n \ Q / / / / / V - v \ \ / / / / / -� -- — � —91S�_ _ _ _- - - - f/ / h / - �/ / \ i l // v _ -- - - -, - . _ -i -/ --- / /- - _ i / V \ ���� o / / /w� / / / /. / / � _ A VA � \ I \ I I / / /O /� / v_� �_ -- �� � -510- -/ /�� � / / l i/ / / \\A_ / / / �gb� A \_A //>/ ice_ - V J / � - �/ / N, / / / / / / / / / V I - __-� VA \ V A I % ) / // �// O tt( A oS� � _- - �, - �i- \ - / --_/ i \ \ \ ) / -- -/ / / //YLuL / / / � / - _ - sA'q \ \ / i / % / / ////�1 �..� - -_ - - ___ --5 j/ / \�— - -'�i -� A�% -- -- - - - f / / / / /5 / / - �o- z r / / / ) r _ A \ ) ) / / / / / // / / /� / / /�/ �� STREAM - ���� - /- - 5 - � v / / - - - / / \ f-5-- / / / - / �/ o w / \ \ �\ \ / \ - -- \ i //// / /� // o//% /// ��i�-=--- - / -_ /i;a5/ ----- ---- \ \\\ J //a- aso \\ /�/// _-- / l / / / / / / / / f m 1 \ S�Z \. _ \ ( \ // \ \ \ 11 /// /j / // / //i// /i / /% / / - \ \ - - \ \ � - _ / / /--_ � — \ �j i -oo� \\\ / / / / / / / / / / / \ - SZ \ % n _ / l / // / / f,z/ /_ �%; / / ---- = --- / \ \ \ / /i/ - \ l / / I \ \ 1 i7 \ - — — — — — \ — — s�� \ — — _ — \ Lo I / I I I (� ` f I ,,, / / — t " _: _ — — — _ O � N, \ �_ / — -- --- _ _ �a\ \\ \ \— — i /,<,y / — — \ \\\\\\\\ I / / _ / / � \ � \ \ ) ��00 \ - S \ - \ / / i \ \ \ --_ � \ \ - ) / I I I I \ \\I \ // /h / / \ . =' --r= -_— --� z==== p LO I \ \\ \\ / // - __ -___ \\\\\\\ �+==aso_'+ / %/�i- � 505=_ _�\ \ \\\ \ //// o / l l l \ \ \\ p ---_ -\ - \ \ - --- - - I I \\\\\ \\)S //�/// //..__.ti�� j►v% _Z � --_- w_--0zs� moo?\\�\\ \\ / / -505= -_—_ __- \�\ \\ _ - / i---'\�\ \\ \\\\ / \ — — — — \ \ 9 \ \ — / I I \ / // / / — Y � —25 —�\ O = — \\Y 0p �\ \ \ + / //— -- — _ _ —� 510��_ �\ \\ \\ \ _ �_ �/ // / /�— — — — \ \ \\ I II // / / / \ / / / \ \ \ \ \ / // ///// / / / \ ( /,/�///". �• -�%/// _ --- J _szs _ Vim.. \\ \ \\i/ //-�, - - \�\_� _ / / -\\\\ \ / / - / / \ --X - x _ - \ \ --- / / __ / l // % I - -- // ors— _ - o >ozX \ \\\ \\ \ / / // '- -- - \ �—_ _ / / / - \ \ \ /� / / — t7 — \\\ _ _ / / \ \ \ \\ / / / / / / \ -sss _ - - - - -�°�s - \� ) l l i / / / \l l '' 111 l / j /// l o� _ _— - -�i / �- - - - - _ w w \\ 1\ \ 1 ) i ///�i // � �5�5_ _ _ \\ \ o // / \ \ \\ \\ \\\ III 1 1 / / / — — _ \ \ / / — —� f / — — — \ \ ) / — — — _ \ \- _\ \ 7 / \ II / / / / , l \ - \ \ w _ �- //i / l/ ///� / l (�'� /_= _ -�i/i = -_ - _ - z- \ \ 1 / l \II \ I (I /i/ /j%�% °Zs _�_ ;- s = \�\\\\ //// // / / / _ \ \� \ \ 111\\ \\ \\\\ /III /I I/ / / \ / / / \ — — — — — \ \ \ \ ( (/ / —� / — _ / — — \ \ IIII / / // //%)I III I //// //// /—� — �������\ / / / \ \�/, \ - ww \ \ m.( I ( / --�—/ w' ---/ / i -- U\\ Il // / /I I�///�//%//�//////// i--_ �_ ��_�� ����_�\\\��S\\\\\ / / / / \ \ 1 \ I I \ \\\\ II / / f _ / \� - /l Y � \ \ � w \ \ w 11 ) /// -- // / //, / ��!r • -// - _ - - - - - - _ - � w \ /l / /// / / / I / // ///i i/i / /ii i� / - _ = _ = -szS \_ �\ \\\ \ \ - / / / / / / \ \ \ \ \ �I 0 I\\ I (I \\ /�// __' / ' / g25//// - _ \ \ / / / ///// / /. / // -0sS- - - \� \\\ \\ \ \ �'\ / \ bbb \ \\ I I / // - �\ ) V O000 V A \ �_ m / // / - _ — �5 - -- _ 1) I /�)�/� / ///// /// - vv \ �A /�/ II l / 1 s �1 \ 1 / -_ v \ v �� oo V\VA\ems\)A\\L vv /5jj//�� j ///'/'i - w ////// /�////ii/52°/= ////� - - v�v�VA �\ \\� �� � / IIIIII AV��ll�i\,� / 1 V A \ V `� `� \ 1 \ \ s\ v /vv\ \v / /i/i'// ///� _ —M - — - v \III I / / ��/i/ ///� // / - vvv v�\ \� \ / / / — — _ ) n A V AA VA` \\\\VA A \� VA / ( r// /% // / //� — m pip — \�y \ I / / , /, I / �/ / / / 5'- — - h \ \ \ v v V \ / / =//ices4o=ornm 1----- vs / o'i///// // / / n _ / ) / 1 \ \VA v vv vvv\vv vv v �� // �/ // / _ _ I ,-/ I I IIII (C _ / /ham/ GRAPHIC SCALE / I 1 A v�v v v vvvv vvv / / //ii /_-- _ v ) ) / \///� // I J I \\�//�/�/ /// CALL BEFORE YOU DIG... ITS THE LAW. / / / / - - �\ v _ _ - / / / / / ) \ V AV�vvA V A / rn - - v / / / //// / / -- v v -- / I h ) \ v VVA % v/// / �j/ - ���� 1- — � / /// // )1\ / / — / / / / I h� / / / / / ) ) \ \ \\ \ \\ iJ� \ VA �n \ ///// N \ I / / // / / //�// /�/ / // / / / - - \ / / / \ \ \ \ s \ V \,o\ � / / / / / i - , - - v / / / I / / // / CALL N.C. ONE-CALL(1-800-632-4949) 100 o so 100 20o aoo / / / v - � / / - / / / / / / / / % \ \ \ \ //// / � _Q rn 0) o- - - v \ / / , / //// / �// //// / / // / FOR LOCATION OF UNDERGROUND UTILITIES AT LEAST / - // /� -, 5-7Oi \ \ \ \ 575— - / / / / / / // / / I ( V // l // / / / \V� / - / / �o / / h� / / / / / \ \ / / // /l -� 0 z / / U // / A/TT / ots / // / o / / 2 WORKING DAYS PRIOR TO BEGINNING GRADING OR TRENCHING. �/ �/- ���� v--- / / / ,5�0 / / / - / / / / / 5/ / / / ///// /// \ \ V / ///� //�/i/ w�� �\ ) // /o/ /// h / v /�/ / M / / ��/ / A V v v / / // - - / z - / //// / / - 1 / / //� / / // I I /// / / / / /// / // / / \ / / -� \ �/ oc // / // / / / / / /� / NORTH CAROLINA GENERAL STATUTE 87-102 / /, / ,/ -- vV�\_ ----- /� -' //�// - / // /! //,/,/�/��/////// //�Iii l( //l�i,�l,l�//,�///��/,/-/ -��vA A, I I il��l/./ ////�%��i� / / l // /// / / IN FEET / - / / /�// /, ,// / , /, / /� , / /, 1 inch = 100 ft. 2817 JIM MINOR ROAD PIN# 9802-59-4690 PARCEL ID# 159117 TAX ID# 9-13-5 14.25 ACRES S JIM MINOR ROAD PIN# 9802-58-9583 PARCEL ID# 159116 TAX ID# 9-13-4 13.71 ACRES 073 PG: 0293 nDn �J ■ U n n n� 5 � 9O 8 ■Q) o C i ■� U W r ,t i cz U � �NMM@j � N a)co��= U) N L0 O O ^� W /\I� U �U�� Z = N � U a)a)a_ N .. § Cz c cz L_ W .. 2 N�0-LLLu J CC� w N w� Z ZI- wv Z Q I� U U Z_ Oe Er .J a= CL �� o � �4 � � O M- x �� � I- 01 0 � � O L) � � � 4 Up 0 w U� In U U O Z O Z 2 � 2 Z O O O Z v 0 E � � 0 � U � w (n � U) oc 0 O oc w wwocw 0 IL oc W IL rn rn rn C) w o 0 0 - I_ N N N CD Q 00 C\O C\O 0 7 f , - 0 0 0 W- N C'') � DATE: AUGUST 29, 2018 HORIZONTAL SCALE: 1"=100' VERTICAL SCALE: N/A PROJECT MANAGER: CPK DRAWN BY: CPK PROJECT NO: 17-002 DRAWING NAME: 17-002 REVIEW THIS DRAWING AND THE DESIGN HEREON ARE THE PROPERTY OF EarthCentric Engineering, Inc. THE INFORMATION ON THIS DRAWING IS NOT FOR USE ON ANY OTHER SITE OR PROJECT. THE REPRODUCTION OR OTHER USE OF THIS DRAWING IN WHOLE OR IN PART, WITHOUT WRITTEN CONSENT OF EarthCentric Engineering, Inc., IS PROHIBITED. COPYRIGHT 2019 EarthCentric Engineering, Inc. SHEET NO. PRELIMINARY SUBDIVISION PLAN P:\17-002\17-002 Drawings\6. Rev04\17-002 Review.dwg, C2.0 - Exist -Demo, 10/16/2019 2:18:03 PM NAK(;LL IU#J I /U,)Ub, I /U,)UJ, I /U.S I U, I n&1 14, 1 ny I I b, 15y I I / 0 0') �, E SETS A / / \ • • r 10 SIO No 20.0' , \ �oopco / ����Q + ♦ + a\ /+ 26.0' 30.0' o v ' ' �0'CCmJm wm0LL, ` �� zw+ + +� + +I/ :+ + + i/ o / �\ zZa- tZ Ow�Q� o 3w ���b 1+ + + + 1� oo SAMPLE LOT ' w/ �' o zoo N �CC�m� �� - j� J+ + \•+04 �I I + + + 70 W / I 0- 0- - - - ; `Ld I➢ I \ ----- I + + 1 0 < IY CV _ O 0 \�\ _ +\ I + SETBACK �'�'/ \ Qwo��ocoED I w 10, SIDE i w co �� 7`dM3/11�0 �3/Ib�l� / I - - - �_. U / ozmo�C6 Dom -r_- -�I > / �\� \+ + + Ld 50.0'10.0,/ . BUILDING SETBACKS: \ FRONT (MAJOR COLLECTOR): 40' �/ a \ o /,� + \ �`' 1+ + + FRONT (LOCAL ROAD): 30' CLEAR OR GRADE SIGHT TRIANGLES %� - / U w / CUL-DE-SAC: 30' TO IMPROVE VISIBILITY IF NEEDED / / �� J oo m N (A � SIDE (STREET / CORNER): 25' 10'X70' SIGHT 00 �_ 00 SIDE (NON -STREET): 10' TRIANGLE (TYP.) °" / Q NO:n W / / REAR: 20' ' /, w o 0 rn Ld o NCDOT "^� - w � m / DRIVE � / " 86 <of 20,000 SF LOTS BASED ON PUBLIC WATER & PRIVATE SEPTIC APRON i z IL o Ld + /+ $ °S > TYPICAL LOT SETBACKS 0 0 bi " 1 1� / �/ m PRIVATE 0= ` \ 50' PRIVATE Lu ��/ T � � DRIVEWAY DRIVE / ' Lo EASEMENT PRIVATE 4/ + 88.41 \ / 76.58' \ STORM EASEMENT i ' y / \ (10' OFF SYSTEM) _ �-„__ - - - - -� - _ _ �� / STREAM /\ is �� / g �• \ \ ��_-----------� / BUFFER CLEAR OR GRADE SIGHT TRIANGLES TO IMPROVE VISIBILITY IF NEEDED I \\ \ \ � 00, '00, 10'X70' SIGHT �v \ \ I '�°�s• \ N, _ _ J !/ / / / w.e TRIANGLE (TYP.) I � / / _ - � / / OPEN SPACE \ °, \ 511,170 SF / 3,211 SF 1 / 11.73 AC 4 24,01166 SF / O O 0.07 AC �°° - - PRIVATE 0.55 AC \ z0.465 SF I 20,000 SF A /\ STORM EASEMENT / o.as AC I o.as AC /F / (10' OFF SYSTEM) / /5 20,0000 SF R30.0' \ / S. I 0.46 AC .ry / \ s2gj ppp ry TO."^ / / �� P�F�. + SRO, / `� J \ / m / 26.0' 24,067 SF °4 0.55 AC / /\ r�'°' "6q2 \ "R175.0' A57.58' AS6.2)• \ \ / 20,000 SF / / / \ 00 / R200.0' �p ° \ / 0.46 AC / O +1 / 30 / \ 66 °° _ EK SANE _ ,q°,.°g• / 7 O / °? �/ /P`1 E T CFtE q \ z0,o00 SF o z4,o00 SF °,. �B OR �• LLJ0.55 AC / /\ lyjNO,,x °� / F o.as AC ry" 20,000 F 0.46 AC 20.0' Cap r ge��Co q.. Ats,.ss•� '�� \ /27 00 R, r"4 �� / / • / / / R 3 2. D Q / ,Jx 00 / . I ` 'vim• 4,,. / / / O s / \ + + / /m FUTURE GRAVEL PARKING \ \l LOT WITH CONCRETE \ or�q� e �s. z0.000 SF ry / PQ 00 /g. \ e q'3 \ 9*c° 92 66 s, \ 0.46 AC / ^ 20. 000 SF Rp i o.-\ HANDICAP SPACE AND / �1 / �? / O + + / \M M�1�5R`�z°`� ISLE FOR TRAIL ACCESS ` 20,029 SF / 28 / / I 19 / \ R200.0' qBz09. 19s R384.2'q °'� AC 3.so / Y /R (✓ 0.46 AC / O I ^ 22,120 SF / \ ° a \ / / 1 / •• �� / �j. S �� �9i o� I PUBLIC 0.51 AC / 9 ?0+0° °4• / STORM EASEMENT / .m + + P � Q .,o• � ! 24,029 SF A9•as• �� 0.55 AC < a / % l60 \ I 10' OFF SYSTEM, / / \ \ J ,� q m \ /: TYPICAL g1p9.o moo. °?\ \/� � o N o / / / / /100�'I• LLI/ °B43\26.0' 7ixoo '1°.28 A34.84' / / \ ' + /•• Ln / . \ \ \ \ �� qS q3� � 11 G�\ / � u� ^ Q m / ��Jar ° 20,00o sF y \ R48.0' 20,140 SF Q N w . / \ \ \ 0.46 AC /� / / / / R32.0' r o.as AC I l O W rn o / 31 \ \ \ I I Iw 1 a + ,g^ z�C-) rn /00 u � \ / 24,720 SF i Lo 20 0.57 AC s/ " / ,000 SF 20,000 SF / 0.46 AC / .. N. 11 .28' 20,686 SF 0.46 AC �A 15 gg< 0.47 AC / 20,000 0.46AC0F \ \ O' Pk"I $ ' CONCEPTUAL WALKING \q4 \ Ld/ 25 22,8s4 SF \ / / \ / �86• A5' _ / w O 0.52 AC TRAIL TO BE DEDICATED ,B "`0' R6 .0' $ ' H \ \ m 20,557 SF \ \ \ / �°/ / R150.0' ai. \ / \ - 9 a ^� 0.47 AC yi & CONSTRUCTED BY / F_ r7 \ / \ / P THE ALAMANCE COUNTY w Ld Y w 34,802 SF TRAIL SYSTEM °ssr H O w V) \ o.so AC / ^ z°\ ,�� s .g" I I \ STREAM 0:' a r \ N \ °p / o. PUBLIC °j.P6 1 12 BUFFER w 26.0' STORM EASEMENT, 16 CLUSTER MAIL BOX / \ w Ld w o \ . Qom/ N� ;+ / \ \ .e }°° 10' OFF SYSTEM, UNIT ON 102.5" X 126" ° \ 14 I I N\ zo'sz AC By R q ® m 2 �' / m © �^ TYPICAL CON. PAD, 8" THICK °6 O m O w . J w a r7 m / < 4 = �,.°,� / 20,000 SF N 13 \ 163.D° PROJECT INFORMATION: 0 0- r \ m I R32.0', %` (GRADE TO DETAIL) \ 0.46 AC I = 20,000 SF U 0_ H Q . Q 20,557 SF Ir a- 0t4i 0.46 AC 0.47 AC , \ I + OWNER/DEVELOPER: / / \ / 0� - J �^ 'g ROBERT M. BRAME 2863 ~ 2 r J16 CLUSTER MAIL BOX ' ,2• I I \ / MEBAN , J0R RD NC 12 012 UNIT ON 102.5" X 126" \ / w \ / ''S,. P7g6 R48.0' CON. PAD, 8" THICK J PROPERTIES INCLUDED IN PROJECT: / ° \ /Q� / \ g3s58' AS6j R63.� (GRADE TO DETAIL) 169.76 2679 JIM MINOR ROAD 2689 JIM MINOR ROAD 00 / Q 73590 PIN# 9802-59-3969 PIN# 9802-59-3974 PARCEL ID# 170308 PARCEL ID# 170309 ,, OQ 20,556 SF '\ �\ \ o + TAX ID# 9-13-183 TAX ID# 9-13-184 0 2.8 ACRES 3.3 ACRES J Z1. \ \ OPEN SPACE STREAM BUFFER _ _ 2863 JIM MINOR ROAD 2817 JIM MINOR ROAD 526.518 SF - - PIN# 9802-59-5721 PIN# 9802-59-4690 Ld IF—@/"�. 20.000 SF 12.09 AC PARCEL ID# 170310 PARCEL ID# 159117 N \ / 22 I8 I 21 \ / 0-1' O + + ao.00 w TAX ID# 9-13-185 TAX ID# 9-13-5 IF—1.68 ACRES 14.25 ACRES 20,000 SF _ Y W / 20,000 SF 0.46 AC \ - / gTREAM - P N# 980CULBERS�N 58-4657 PIN# 98020--58 -9 83 O AD W Q r7 / 0.46 AC I \ / P`gg. �'' + + + + I /+ + U 0- m / ' !i + + + + + + '` + + PARCEL ID# 159114 PARCEL ID# 159116 TAX ID# 9-13-4A TAX ID# 9-13-4 \ / 6.01 ACRES 13.71 ACRES 4'se6°\+ + + + + + + + + + TOWNSHIP 9: THOMPSON p156,66' _ DEED/PLAT REFERENCES: S.' / Lr) N + + + + + DB: 2823 PG: 0093 PB: 073 PG: 0293 S� .01' / / ' cn ,n DB: 3239 PG: 0957 0 0 00 + + DB: 2487 PG: 215 PB: 073 PG: 0293 m m W W a m of 00 00 1-1 \ W of - a m \ of 00 CALL BEFORE YOU DIG... IT'S THE LAW. CALL N.C. ONE-CALL(1-800-632-4949) FOR LOCATION OF UNDERGROUND UTILITIES AT LEAST 2 WORKING DAYS PRIOR TO BEGINNING GRADING OR TRENCHING. NORTH CAROLINA GENERAL STATUTE 87-102 �• I O U 0 965.84' •• / O U / IZ W CID Cr Q CID O00 Lo MC� rn U��I 0r,0°' Of 006 Q 0) CD �tlH U 0 of 2 0) >oza + / S01 LS. CnB2, CnC2, CnD2, CnE2 = CULLEN CLAY LOAM = GROUP C RvA = RIVERVIEW LOAM = HYDROLOGIC GROUP B WtB = WYNOTT-ENON COMPLEX = HYDROLOGIC GROUP C FEMA MAP #3710980200 K, EFFECTIVE 11/17/2017 FLOOD HAZARDS PRESENT TOTAL ACREAGE: 41.75 ACRES BY SURVEY TOTAL # PROPOSED LOTS: 33 LOTS AVERAGE LOT SIZE: 0.49 ACRES (NOT INCLUDING LOT #33) TOTAL OPEN SPACE: 532,630 SF OR 12.23 ACRES WINDING CREEK TRAIL: 316.09 LF FOREST CREEK LANE: 1,186.86 LF PRIVATE DRIVE: 1,257.87 LF (IN EASEMENT) GRAPHIC SCALE 80 0 40 80 160 320 W W U Cz W O U C N r � i (13 CM CID � �OCOO U co N �NU-)M O U U a) b) Z T T cz c cz .. J N2oILL Lu IRT Ir Lu CCV Lu � Z Zo- LuU Z Q U U Z_ � J I_ IZ c Z p Z Lu � Lu Z � O O O Z U O 01: 0 01: 0 oc 0 O oc w wwoCw 0 IL 01: W IL rn rn rn � Lu O O O F__ N N CV N Q 00 C\O C\O Co CD O O Lu r N Co � DATE: AUGUST 29, 2018 HORIZONTAL SCALE: V=80' VERTICAL SCALE: N/A PROJECT MANAGER: CPK DRAWN BY: CPK PROJECT NO: 17-002 DRAWING NAME: 17-002 REVIEW THIS DRAWING AND THE DESIGN HEREON ARE THE PROPERTY OF EarthCentric Engineering, Inc. THE INFORMATION ON THIS DRAWING IS NOT FOR USE ON ANY OTHER SITE OR PROJECT. THE REPRODUCTION OR OTHER USE OF THIS DRAWING IN WHOLE OR IN PART, WITHOUT WRITTEN CONSENT OF EarthCentric Engineering, Inc., IS PROHIBITED. COPYRIGHT 2019 EarthCentric Engineering, Inc. SHEET NO. CQo) o 0 ':\17-002\17-002 Drawings\6. Rev04\17-002 Review.dwg, C3.0 - Site Plan, 10/16/2019 2:18:08 PM ( IN FEET ) 1 inch = 80 ft. PRELIMINARY SUBDIVISION PLAN F'AN(-LL IU#J I /U,)Ub, I /U,)UJ, I /U.S I U, I n&1 14, 1 ny I I b, 15y I I / _ _ ry / '`� aw0Jwoocoao L�� W �JCOCO oZtT0m MM ■ Z SETB CA K , / ��Z_a- a U 10 SIDE N' CLEAR OR GRADE SIGHT TRIANGLES o / / _ 20.pw r � TO IMPROVE VISIBILITY IF NEEDED�o z < r- 00 � 10'X70' SIGHT P� i 0coo 00 � _ TRIANGLE (TYP.) LL (.0 a N04 m rn Z P�000 SAMPLE LOT a) wo1`-� 10m:*kio 4 NCDOT a_�za ■ia� ^^,, I� I DRIVE / z ` W tr APRON W 10, SIDE SETBACK � M W L_ � oo 50.0' 10.0' / �\ \r W BUILDING SETBACKS: \o \ Y ry�� FRONT (MAJOR COLLECTOR): 40' � \ \ U FRONT (LOCAL ROAD): 30' L / \ \ 12.0' / CUL-DE-SAC: 30' \ \ 50' PRIVATE PRIVATE SIDE (STREET / CORNER): 25' / �� �/�+'� / / 00 � � I- � '� DRIVEWAY DRIVE .0e ^, SIDE (NON -STREET): 10' Lo \ \ \ \ \ EASEMENT /� W REAR: 20' � / / � � \ � \�° \ PRIVATE / i �_ _ � / ' \ \ STORM EASEMENT �o / ss.a,' 76.58' \ (10' OFF SYSTEM) / ♦"� 20,000 SF LOTS BASED ON PUBLIC WATER & PRIVATE SEPTIC / / _ - _Ts+6ns 4 77+a=Cz - 1� 4S \ \ \ x / - I ---------- - +q TYPICAL LOT SETBACKS / \ \ �6�, / �k° - - / ui xW41-I'l- CLEAR OR GRADE SIGHT TRIANGLES 10'X70' SIGHT / o \ do. \ \ \ \ / j / / TO IMPROVE VISIBILITY IF NEEDED TRIANGLE (TYP.) / \ ia+ - - - O / / \ - - - - O � OPEN SPACE \ ?°63 \ - i / � 511,170 SF («oZ) SB QVN-QIY9 ON 11.73 AC 0.46AC3,211 SF J� PRIVATE I I 0.07 AC 'see, � _ Q Oo P/ 24,016 SF _• / 0.55 AC 20F 20,000 SF /^ STORM EASEMENT y 10.46 AC N s8 (10' OFF SYSTEM) 20,000 SF 0 U C CU T N � CN CID 0)OC)1- U co C CV UZ T T cz c .. cz CZ J NOLLLu IIIIIIIUII/p�i/ cc� W C\I z w V) ¢ �z'�"=wz • , 111 J aU .,. •GHQ z 0 a IZ 2 / .cam o0 9e. 24,067 SF / O ' m o oe �9ao 6� 0.55 AC � / � / P1ti / \ \A• O q6Q \ R175.0' A57.56 / 6.27' \ 20,0 0 SF co / ....... ..... \ R200.0' o' \ / 0.46 AC / 1,+ �99 / o SOILS FOR SEPTIC \ 1001, P` REST CREE \ 20,000 SIFrn 8 70 It o° 24,000 SF ee, �sFO \ q, � 0.46 AC N / \ 'e' / Q / 0.55 AC / / \ x 2xoo - _ °o, N 20,000 SF / O ILL)2 \ q� \ / 0.46 AC 20.0' / Q P / / \ q,g N�7Nc \ 42 / A ,a 1. ss. \ s?\ / \ ' p■■I' W /\ R.A \ / 1y0 / `` ° �6 L) Rq/� R32.0' I} I} I} Pph 10 / �O. \ / / / J Oo \ 9?9 oS6 x W 90 FUTURE GRAVEL PARKING LOT / \ q�� °9 .�6' q ,s,° . ` 20,000 sF N /' �o 65. WITH CONCRETE HANDICAP SPACE \'dS2 \ ` \ / 0.46 AC 10 / \ AND ISLE FOR TRAIL ACCESS I 9*0o A66.5 20,000 SIF / 'n ry000 ' / 29 / / R200.0' I / /3.so R384.2', 0.46 AC 20,022 SF 1 g \ 0.46 AC / / 28 ' PUBLIC 22,120 SF / 462 °g �, rT1 STORM EASEMENT 0.51 AC \ \ 2p*oo ,4� \ \ �� F� w � i / �0�• ^ ,�'.:. •� 24,029 SF -- o & 9.85' �` 0.55 AC a 10' OFF SYSTEM, qO 06 TYPICAL�/ ~ CO Ld rot, �a 1oa\ °O �`C-.'/ 1�+■ll to 1.0 18 c Reese, 20,000 SIF h / z9. R32.0' A� R48.0' 20,140 SIF 0.46 AC ry 0.46 AC I ± I / \ 1 U, h" OD \ \, ' r� Ltl ut 24,720 SIF/ sg / \ \ N o m I \ 0 16 0.57 AC n 1 N \ \ 20,000 SF / I v + 184.93' 1-1 20,000 0,0 0ACF / 0.46 AC \ °' l 15 20,686 SF \ 0.47 AC / / n" 20,000 SF 0.46 AC PIf- $\ 25 22,864 SIF / CONCEPTUAL WALKING / \ g4'Ss as R63's?�4• o -"' 0.52 AC \ R� 0.0' TRAIL TO BE DEDICATED / ao. .0' 20,557 SF 0.47 AC \ P �� &CONSTRUCTED BY THE ALAMANCE COUNTY \ \ ` \ TRAIL SYSTEM 'o4•ss, >_ IL IL IL W N 34,8002 sF \ / O w Q � 0.80 AC \ \ / / \ 20? \ � > ,,a'�.�ry� / I I STREAM \ m A�ao A / �2 0. / s'2s \ 12 BUFFER ♦ Ci o / ��60 , k° PUBLIC N 9 o ��\ A67.36' 26.0' STORM EASEMENT, 22,634 SIF w \� \ s.ae / 16 CLUSTER MAIL BOX \ °.. \ °° 10' OFF SYSTEM, 0.52 AC ' 0 0 o x TYPICAL UNIT ON 102.5" X 126" sR \ / 14 I I \ ~ J ~ 24 , / CON. PAD, 8" THICK �s 13 \ w o0c w P a� (GRADE TO DETAIL) 20,000 SF \ PROJECT INFORMATION: 2 2 20557 SF R320' \ 0.46 AC 20,000 SF Z 0.47 O ,.0.46 AC OWNER/DEVELOPER: O O U O \ AC / U N / I a o+°° �90 \ \ \ ROBERT M. BRAME U C3 Z U \ ? N Q o I � M < .\ / � 2863 SOUTH JIM MINOR RD O p[ / MEBANE, NC 27302 U w U) 207.00' a 16 CLUSTER MAIL BOX 3�'?' w w �w o0C w s� R48.0' \ PROPERTIES INCLUDED IN PROJECT: 0 0- pC Lu 0- \ �' y� UNIT ON 102.5" X 126" 2679 JIM MINOR ROAD 2689 JIM MINOR ROAD a / q, s,, P�6 CON. PAD, 8" THICK \_ PIN# 9802-59-3969 PIN# 9802-59-3974 rn rn rn rn m \ q36 S6, e6 (GRADE TO DETAIL) ,6s.7o' PARCEL ID# 170308 PARCEL ID# 170309 LLJ o 0 0 \ A3� R63.0' \ N N N o . J \ ?o> a3.o3' Is 111 2 8X ACRES 13-183 3 3X ACRES 13-184 0 N � ° Q ao co co � DD Q 20,556 SF / / \ 2863 JIM MINOR ROAD 2817 JIM MINOR ROAD 0 0 0 CD / J / 0.47 AC / I \ \ \ PIN# 9802-59-5721 PIN# 9802-59-4690 w r N Co PARCEL ID# 170310 PARCEL ID# 159117 oC �o° \ N TAX ID# 9-13-185 TAX ID# 9-13-5 Q DATE: AUGUST 29, 2018 OPEN SPACE STREAM BUFFER 1.68 ACRES 14.25 ACRES � HORIZONTAL SCALE: / 20 526,518 SF i CULBERSON LN S JIM MINOR ROAD VERTICAL SCALE: N/A 20,000 SF 12.09 AC PIN 9802-58-4657 PIN 9802-58-9583 # # PROJECT MANAGER: CPK 0.46 AC PARCEL ID# 159114 PARCEL ID# 159116 DRAWN BY: CPK TAX ID# 9-13-4A TAX ID# 9-13-4 ' 6 6.01 ACRES 13.71 ACRES PROJECT NO: 17-002 I _ - a 20,000 SF �' � - DRAWING NAME: 17-002 REVIEW 20,000 SF 0.46 AC -_ \ 6e • - _ • _ TOWNSHIP 9: THOMPSON / 0.46 AC I ,g6' ' i� • • � ' DEED/PLAT REFERENCES: THIS DRAWING AND THE DESIGN HEREON ARE \ P ` • • �/ ' i STREAM THE PROPERTY OF EarthCentric Engineering, Inc. \ / / ' • DB: 2823 PG: 0093 PB: 073 PG: 0293 THE INFORMATION ON THIS DRAWING IS NOT FOR / / / \ I I \ • / / DB: 3239 PG: 0957 USE ON ANY OTHER SITE OR PROJECT. THE REPRODUCTION OR OTHER USE OF THIS DB: 2487 PG: 215 PB: 073 PG: 0293 DRAWING IN WHOLE OR IN PART, WITHOUT \ I ' , • �/ . / I+ I+ WRITTEN CONSENT OF EarthCentric Engineering, Inc., // • / I I SOILS: IS PROHIBITED. / .SZ \ I / /j.%' - j CnB2, CnC2, CnD2, CnE2 = CULLEN CLAY LOAM = GROUP C COPYRIGHT 2019 EarthCentric Engineering, Inc. A's6. /�' /' j' i o r7 N + + + + RVA = RIVERVIEW LOAM = HYDROLOGIC GROUP B 40"ss, / \�� N WtB = WYNOTT-ENON COMPLEX = HYDROLOGIC GROUP C p156 6s I r ' / / / ♦ ' o0 0)� , I FEMA MAP #3710980200 K, EFFECTIVE 11 /17/2017 SHEET NO. GRAPHIC SCALE (I / �' FLOOD HAZARDS PRESENT CALL BEFORE YOU DIG... IT'S THE LAW. 60 30 60 120 240 � ��°' CALL N.C. ONE-CALL(1-800-632-4949) FOR LOCATION OF UNDERGROUND UTILITIES AT LEAST 2 WORKING DAYS PRIOR TO BEGINNING GRADING OR TRENCHING. ( IN FEET NORTH CAROLINA GENERAL STATUTE 87-102 1 inch = 60 ft. / 14 f TOTAL ACREAGE: 41.75 ACRES BY SURVEY TOTAL # PROPOSED LOTS: 33 LOTS AVERAGE LOT SIZE: 0.49 ACRES (NOT INCLUDING LOT #33) TOTAL OPEN SPACE: 532,630 SF OR 12.23 ACRES WINDING CREEK TRAIL: 316.09 LF FOREST CREEK LANE: 1,186.86 LF PRIVATE DRIVE: 1,257.87 LF (IN EASEMENT) C Qo) O PRELIMINARY SUBDIVISION PLAN I,17-002\17-002 Drawings\6. Rev04\17-002 Review.dwg, C3.1 - Site Plan, 10/16/2019 2:18:13 PM NAK(;LL IU#J I /U,)Ub, I /U,)U'J, I /U.S I U, I n&1 14, 1 ny I I b, 15y I I / - 530- -- / --- I 1 1 V ,- /- '--V - - -�� � -V �A V � -- �-- v v-V �JJ\A-- -�A-�-- A -- \\ V -v \� - - -- V A\ / / / A V / �� \ V A v - -- -- - v - v V A A ti - v v v v v � � v - _ AA \ VA \ \� v_ � - v� - / v - - - - / _-�v v v v v vv - �� - v� vv\ -V A - v v- v _ _ - - A A \ / - - - V A I I I I / - - Sps, A A A v \� -� ��� ��� VA V A\VA �' - - - \ I / / / I I / \\\ \ \ \ \ \ \ \� \ \ \\\ \ \\�/^ \i - - - - - - � - - \ � � - - - - I �/ - - - \ -V A � -- \ �s � � Fg \� A \A A --ZS �A V\ VA S Ate _ _ - - V �� - - - / ---- / / \I / \ \ s£ J \\ s \ \\ \ \ - _� / /- \ \ \ \ � \ \ - - \ \ - \ \ \ -v - - - v v v �v - �A \ \ v v v - v // - i A / v v v v v v- v \ v v - / - ^ \ - - � - / \ / / - - \ \ � - - � � \ \ \ \ \ \ \ \ \ \ \ - - - - - - - \ \A V A / / - / - / f A I I I / / / A A A - - -- - � � .9 ��� �� �A A A \ \V �� A�\ \ , _� VAAV\ - - / - - - i V A _ / - - - - ) A / / // /� v v \� - CULVERT 2.0: v - v - - - �0_ i� \ - I '\ - 1 v v v v v v v V A� �- \ v v - �// v v � � v � DRIVE PIPE \ vv A V - �/ - -- - \V A - / i -Z V / / i�� ��- - � - � �- � may- �v v vv v �Av FES OUT: 519.00� - - - \ / / - / � v y / v v \ - - - A \ \o - - i / / /�/ v �7 _Vvv 28.8 LF 15" RCP \ \ \ \ - / �/ / - v ��/ Vy v @ 1.00% SLOPE \ V/ \�� V A h _ v - v v v \ APRON @FES: - - �/ ' - - - - A v \ V / 5g5 / - - A � /� \ - - A� - I �� vv / v v A \ \ \ s s -CLASS A EC STONE: �� --� \ -- / �/ v t � - � - / I \ - - - - \ \ \�s\ \ / - - / / �� v - A� - � A \ \% �./ 1 -- � �� \ \ \ \ \ 6'Lx7.5'Wx12"T - - _ � _ � � � v% �� �_ \ - - ��\ V A \ A V v y v vA \ VA � � / / �� / - - - / � / / � 1 V /( / -� -- \may s�//�\ ROCK PIPE INLET - C-- <- � � Cam- VA Kv '-- "/ - � / AVAA � �/ - - - �� /T-� /�-- v\ \ - - / �� / / - - - - sv -A y \\-j%��_-- \\VAA\\� -/ /� �/ �' - /� // l / ) / / A �/ �°ss��-- _ vv�//� VA PROTEC110N, vvv vv - \ \ �/ / / / o/�� \\ i / - / // / \ - -_ -_- � _- -- I- \vv v v Vv,v, y �- - 7 / � '/ , I / � A V\\\ \� � -i - --- /// �/ / � � / - vA /� \\ \ A\ VA\\ FES IN: 519.29'Vw / / / \ - ^ - - -- / / // ��,� / V � _ f j V A\A \ V A V \ V A CLASS A EC STONE: \ V A V� / / v V / \ - - - FES OUT: 548.13 - - - - - - / ao - - -_ / / �� \ \ - \ ✓ \ \ o \ \\\\\ \ 4.5'Lx4.5'Wx12 "T \\\ + V A �0 -� / \ o / // / �- v -v / \ s\\ V \ \ 0 /xV-� / / / I / v�-- A\VAs v -- APRON @FES:_ � � -- �5 / -_ // ��� v --._ v v \ / v� A VA�� \\ V A\ \ � VA \\ \ \ \ i � ��A / v A \ VA � _ CLASS A EC STONE: - - - _ - / // � - - �- - /� +� ) v v \ - A \ / \, \ \ V A \ A \ V A VA \ \� \ \ V A, � � / i --- V \\\�� - 6'Lx7.5'Wx12"T= -___ -_ ,iij� / �/� / --- \�� \ \ \ A, \. // �\ \ \ V A� \ VA\ \ \� \ \\ \ \ \ / / / /\ / - - - - - - - - - _ �' / - �� / SKIMMER SEDIMENT BASIN 1: / I \ \ V A A V V A � I / / \ \ \ - - - - _ - - N / - g� - - / SKI 1.27 AC / \ V A \ / � v ------ �/ / / � // v 1 \ \ \ \ VA \ \ \ / J I / ----- v-v\ � --------- � A�//j z�- / ---/ TOP OF BERM: 549.50 v� / `"i- 1 \ \ \ \ \ \ \ \\\ \\ \ \ \\\ \ f�/I I i I l I I / / i � / - v - - - _ CULVERT 1.1: - - " A %/ / / CREST OF WEIR: 548.00 v \ \ \ \ \ \ / / - �� - / / - / L v- \ \ V \ \ \ VA \\\\VA\\\\\� I I I DRIVE PIPE - - v / / / / / LENGTH OF WEIR: 6 / / / / v v v v 32.7 LF 15" RCP -- �� y - / / �� -DIMENSIONS ®WEIR:80'Lx25'W v -- A - V v _j \ \ \ \ \ \ V A� \ \ \ V A \ \ �, SLOPE DEPTH FROM WEIR: 2 - - \ \ \ \ \ V \ \ / // / v v- @0.52% ,--v /5ygy� - /d , / °� \ v -- - -\ - _� \ \ � \\\\ VA\\ - \ i � I / / 12'X50' CONSTRUCTION ENTRANCE �x - / // i X/ ) 3�BAFFLES REQUIRED . --� y - A \ \ A \ V A V \ / � �� / ,,A 2 DIA SKIMMER W� 1 DIA ORIFICE \ \ \ \ \ \ \ \� \\\ / / / L -/ / \ / / OUTLET TO CLASS A EC STONE: � \ - - - \ \ \ \ - - _ \ \ \ \ \ \ \ \ \ \ \ \ I \ \ \ \ \ \ I I I k I I I I / / FES IN: 548.30 / ♦ �� \ - � \ \ \ \\ \ 1 I \ \ \ \ \ o / / APRON @ FES: \ V1' i / 3'X3'X12" DEEP APRON v v v v > > / J \ \ V A \ 1\ 1 1 1 1 A \ � \ \ \ \ \ V A \ \ I V / / CLASS A EC STONE: \ \ \ \ \ \ \ - - \ \ \ \ - - - - / \ \ \\ r I / / \ \\ / \\\ I \\\ \ \\ \\\\ \\\\ / 4.5'Lx4.5'Wx12"T . / ��/ \ \ ♦ `` 1 /\ - \ \ \ \\ \ \ \ - \- \-------- / � / \\\ 1\1 1 I \'\ \ \\ 1\ \\ \ / / \ I � - o / 0- v � \ / \ / \\ V�VA \V A 11 � \ / - \ \ - - \ \\ _ _ / / \ \ \\ \ \ \ \ I I 0 - / A \ °SS \ \ V \� \ v v A vv - ---- - / / / \/ V � \VA\ \ A I A I I I A / i / A % v - v v - - -� / \ I - z / / ROCK PIPE INLET /� \ \ - v v / - v v \ \ \ \ \ - - v v - v v v - \ v _ - - - - - - - - / / /\/ / \ \ \ °1I I I \ I A I I I � I TAILDITCH ALONG ROADSIDE AS PROTECTION / // / V A - \ \ \ \ A V A \ \ A v v v - ' v - V A v v v - - - - - / / / A \ I / NEEDED TO INSTALL CULVERTS - �i - \ �- - A � - v A A V \ v - v v VA v v v � - - - - - i �/ / x� �� \ III I I V A�N\ I I / AND DIRECT ROADWAY RUNOFF � ii / - \Vzzl �'�� , � �� '_1 � \ \ V A \ \ \ a, \ / \ � v v v v - � - - - - \ \ \ � I \� V I I / SEDIMENT BASIN - - / // (/ / / / -�� �x�\�7�� v - \ �\ \\ V A \ \V A � A % / / BLOCK AND GRAVEL v v �� - sys� I \ \ I I I I � \V A \V A \ V A / / / ,g�O�� / /-�� ����� \ V A� \ \ /� I / / _INLET PROTECTION A - �� ---- I/ \ \ V � \ l«-- se ava-arm �nr FES OUT:550.25 � LIMITS OF / / / /� i - �sss� A� \ \ V A ) i I I I / / / / / v �� � � � v v - - - - - - ! �/ A I I I I V� \ � I I �� / DISTURBANCE: / �j/ �o ���\ \ \ \ / / I / / - Vv ��� v _ - - i �, / / / v / APRON @FES: / � / � / \� � I / / �, ) �c v v v / I I � V \ - CLASS A EC STONE:. 5° 233,605 SF OR - / V ) h / - V A v - 5.363 AC /\ � �♦ I V / / / / /) // / - v � Fs / / I / / �� I 1 1 � I) h/ V 6'Lx7.5'Wx12"T i( _ _ \ \ \\ / / SF� / -�\ V I I I �v� v - / v V / �--n..'\\ ,\ y v / �� - v _ / / / 1\ / / / / / BUFFER // \ V / � V / / / o i - amA Vs V YARD INLET 1.0: \ - / / / / / / / V / �s� \ / v \ \ \ ��, \ V A WEIRS: 525.00 / _ - - -r- - - - _ -- / / �� / / / ///�j% V \ \ \ V CULVERT 1.2: / �� \ < v ♦\� V A \ \ \ I \ INV OUT: 521.60 I ( - _ �� - - - _ - - i / // ///- / /� /// //// //�� - \ \ \ / / )I V � \ _ ENTRANCE PIPE . �x / - - A ♦ \ \ ( ) f . / - - - / / / /// /A/ V I V 60.9 LF 15" RCP A \ \ - v - A A \ A`\�'� V� I I \ \ ) A \ - _ i / i / ///�/ i�/ //�j/� ��/ . / A V -ops LIMIT OF INITIAL CONSTRUCTION @ / i - / / // // / / /// o / \ �'s' A \ l �� V A ° \ 1 \ \ \ -- ///// �// / / V / @ 0.50% SLOPE - /�,n GJ \ \ \ \ \ I I I �� / - � TEMPORARY DIVERSION AROUND CULVERT - - i - / /// /�// / V / \ \ V � V��'� / \ V -- - - i /// / // // \ t - l i / V A � A \ •\\ \ J� \ \ �v v - - CONSTRUCTION. CLEARING AND GRADING - - - - - - , //�/ /, /z // / /// // I V \\ \ 12'X50' CONSTRUCTION ENTRANCE / �� / \ \ \ - � v _ _ - - - - - ///// //// / / / / / \ \ \ ,ass / ) \ �� \ \ V `�IN \ \-\ �� \ \ V � � � , / / v v �c>s _ - - BEYOND THIS POINT IS PROHIBITED UNTIL - - - - / i / /� Zzzz'. j/ // / V A ) \ / A \ / s \ A V A� A \�� �a 1 f / / / - CULVERT 1.0: - -CULVERT HAS BEEN INSTALLED. MOVE _ - - - / �� �A��(/,'(( �j j �// //j /j�//" \ FES IN: 550.56 � / \ � \ \ \ / / TO PHASE 2 OF SEDIMENT AND EROSION -osg - - - - A\ 1' / � / \ \ / - � - 57.9 LF 24" RCP - _ - - \ \ V A APRON @FES: / V A \ \ L V v \ A ' \ ss � l l l - v - - - - - - - - / i \ / // � / �/ /� V A \ CLASS A EC STONE: /\ / / \ \ A A A �E / /) / / - �@ 1.04% SLOPE CONTROL (SHEET C4.1). - - - - - 11, / Z/ / i �// /� \ V \ v �, - --- - �// /// / -- // // / / / // - 4.5'Lx4.5'Wx12"T FES IN: 538.50 \ V � \ \ \ \ / I _- �- - - - - - - - _ - %//// �j i / ///////7 V A A \ \ - _ - -gas- -- �/ //// / - - \ \ - V A � / I - - v - - - - // // / - / /� , APRON @FES: A \ _ �- - �/ // V A v - �� \ \ \ II I \ I I I I / / � vvy------- - 5zo---/' iz iz ' �i/,/ �// // \ \ \ V -- -- CLASS A EC STONE: A \ / I ( \ I I oI V -- __ _ --- --- -- ---i// // / - / \ n �' -- \ \ / � \ \ \ - v s -_-------- �'�' ///�/ / - - ��// V A �s \ \ / 4.5'Lx4.5'Wx12"T V A V A V (\ \ V A \ \ v I I I � -fie - -- /�/ / / _- -- /�/ / A \ FES OUT: 521.00 1 v - - - - v \ - - /� ��/i /// //// i - \ \ A / V A \ v / I I A\ V A v V v v y v- - _ _ /� �' �/ / /�/A-/��� - � \ \ \ / \ \ \ \ APRON @ FES: A r- - _ - � _ _ - //� / / v \ v I I I I � 1 \ \ \ \ _ _ ��v -- --- ---- - / /ii Z /// l \ \ \ \ \ V A \ \ \ CLASS 1 RIP RAP: A - - s v v _ - - - - - - - - - - �' /\ % / / / V A A \ \ v ROCK PIPE INLET - - - \ V A V / / / h� - - - = - - - 5/ - / / // / / V I ( / A / I I A \ , V A 16'Lx18'Wx24"T \\ \ y Av y _ i i �� i i/ // j/ //� / \V A V v PROTECTION - �� V A V A \ V / / \ \ \ V A V A V A - - v v - - - - - - / �/ / // \ v . �� + / / � ♦ / A / 1 \ \ \ � v V A\ �� _ _ �� v vvA ----- - � '- - �// ///// %/ s V A \ \ �� / A CULVERT 4.0: A V A \ � / / / \ \ \ \ V A \ V A \ \ VA� \ \ \\ VA \V A \ - � v � vvv v� - � - - ��/ /i //o/ // D // V A \ ���� � V � LIMIT OF INITIAL CONSTRUCTION @ / A A \ \ V A VA V A V \ \ \ - _ - A v _ i - - - / / 5 // 9/ p. / / 53.5 LF 18" RCP / / I \ \ \ V A \ \ \ V A - v v v - - / /i / // /� / / \ \ \ / / / � \ @ 0.56% TEMPORARY DIVERSION AROUND CULVERT \ \ \ \ \ \\ \ \ \ \\ \ \ \ \ \ - - � \\\ \\ - - - , - - - - - j �/ // // / / / \ v / / o x SLOPE \ / / / I \ V A V \\ \ \ V A A \ \\ \ \ \ V A\ \ ' -` - - - '� � � // // 1/1, / /,� -/i \ V v - A /� �� oa - - - v A CONSTRUCTION. CLEARING AND GRADING \ A \ \ \ V \\ \ V A \ V\\ \V \\ \ \ \ \ vsos v v vvA - - �� - ice/ / // / / / \ \ � / \ \\ \ \ \ \ V \ v\ vv -- A -- 5� - -- // // //j / \ / - - - v v BEYOND THIS POINT IS PROHIBITED UNTIL / / \ \ V A \ \ v v v v - - - � - - / / /, / / \ \ --- -r--- - // / / / ,/ / \ - A V / - - v CULVERT HAS BEEN INSTALLED. MOVE / / V A V \ \ \ \vV, A A V A \ \� V A� \ / - v TO PHASE 2 OF SEDIMENT AND EROSION � / / A \ \ \ \ VA \ \ \ V V A \ v - - _ ��]�� ��� /' I // / 1 � / \ \ V A / �ys� gtig CONTROL SHEET C4.1 / / J ) \ \ \ V A \ \ V A A \ \ V A V A \ V A \ \ - �i% / // / / / / / \ \ / V �� \ » A - / / / A \ \ \ \ \ V A \ \ b \ V A V A \ V A \ \ ii iy i �i / �o / / o --- / \ \ \\ \ \ \ \ \ A \ \ \ \ \\ \�A A y s - � �� / G / \ v " V \ �� - - I / / \ \ \ \ \ \ v moo - - - - - - \ V \ � / 11 V A V A � - / / / / / I \ \ \ \ \1 \ \ V A V A \ \ , \ - � %?r I - / �P / / v V I �[ �2 �� - � -/ / / / I �\ V A \ V\\\ \ 1 1 \ \ --- - - - - / \ � � V \ I / I♦ I ,%,oa - v / / / / / I I I I I I I 1 \ V A \ V1 1 V\� � � �v ;� � % / //�v.� / i / \ / y v - I I I 11 11 \ vv % - - / / / / / / / I I - I , , - - -// - -' v / / I I / / " I I ,' , , I � , I I � I I vv vv ' � v v1 v 1 ���v�_ -� � � //// /' I V A / I ♦ �, > - v � �-- --, v� i i / / / to � � � I I � � I I I I I V A I I I A v'495- - - / // / / / ROCK PIPE INLET I �v - A � - - - \ V ,� ♦ � / % / / / / I 1 I I I I A � ;A = V /� / /.. ,-�v / / / �/ I�� I �I � II II v�-- / /,. / / �0 ��� � �-' / PROTECTION I �� �/ /I � N� \ \ , \\ \ 5� / / / / / I I I I / I / I � I 1 � /- / i � i xo V �� �--� A -/ 5 / / / / \ V 1 // / / / -- . � �' --- \ I ) I / 1 /7� - v v\vv v ♦ // / / / / / I I I I /III /I/I////////'III1' III I�I II 11 \ I i /\./ / / / � /i / / - I SEDIMENT / / / xso - A FES OUT: 538.20 \ V / / I / I I � ( /1 / / / / - / I I FENCE / / / - - v - \ \ 1 v / % I I I I I I / / / / �/ i / / / APRON @ FES: � / / / I I I � / / / / � / sss �- / ' I -/ - CLASS A EC STONE: v \ I I I I I I I y � / / - / / �/ / / G / / / / I I I I I - 6'Lx7.5'Wx12"T v V � / / I I I I I T / � // / / / /-- 1 1 �jv v vv v- � 3 0 y I �'vv \ \ 1 1 1 1 �� �% / / / /� / +� / / * CLEAR AND GRUB ONLY AS NEEDED TO I I I I I I / / / - -A v � \ � V \ \ \ I / A' / / / / / � / - / PROVIDE ACCESS TO CULVERTS AND I I - / v -- v -- v v \ V �� I I I I I , I � \ \ \ \ V ,n / 13 // 6`� /' / / v v \ I / �: ;. / / / DRIVE PIPES. INSTALL PERIMETER / I \ -1 o / / � - - - - - Vv v \ \A °� - v v� \ v � ) A \ �'�,A V A \ \ I � � / / P / / to s v � I I I I \I \ \ \VAsV A V A \Vv V \\l \�°�VI I I 1/ I/� / / N �::::, �/ / - MEASURES, BASINS/TRAPS AND / I I I +- / / - -- -\VA \ I \ V A v v v v v -- / \ \ \ \ \ \ A \ VA /.P� / / / / "� / / / DIVERSIONS SHOWN PRIOR TO INSTALLING ) / / / \ - a \ V A V A \ \\ \ / � / / / _ CULVERTS AND DRIVE PIPES. UPON / �I/ / / - A \ / v V A - v v A y / A V A \� \ VA \ VA \ VA VA\ \ \ \� V A\�oo A A / /�/ I I . �� 7`7/ \ / / / / 40� / / / / COMPLETION OF CULVERTS, FOLLOW / / I I / w/ / / v A V 1 / - v v - A \ / A V \ \ \V \ \ \ s l / / / / / v \\�/- v- Vvv v v v �V / / / / /�\ \\\A \VA \ \ A\VA\VA\ V\\\VA V /\VA VAAV111\ /� �/ \ O \ I / / / // / / SEDIMENT AND EROSION CONTROL SHOWN / / � I I / \ \ A \ \ �' v \ / 1 - v v V A / A \ \ V A \ \ \V A \ V A\ VA \ \ - \ �, l l l / / / / / v V - v 1 v v v / AV vv v v v vv v vA\ t\ �I // �P/ A I / / / / ON SHEET C4.1. I \ \ \ \ \ \ \ \ \ I /. / / / / // \ v v v v � v v v v / - 1 \ v� v v v v�sv vv v� v V A I I �. \ I I ( / - / / - _ �� ---� / �� / / / / / � �/ I� \ v v �� v v� v v v v�/ / v�vwv' v \ / V \ / / v v v v vv v v v v vv vv vvv vvv A \ I l / \ ��j \ \ / / / / _ - --- / / / / / /� - / / v v v v V / / \ vv v vvv v vv\v/v v A V A / / / / \ / // I �' / ' v // V v - \ v v v vA\ \\A\ \\\I / \ / \ \ / � // - / - / / v v v \ - \ V v \ / / �I,I �I / /v -�' v V -�' - v vv �� / - v v � vv v v \vvv V / �. V / / , / I Iv v s / - vv vvvv v v� vv v \\ \V \ \ A � / ( \ v v v v / v v vv v v v\ \ \ \ V 1 / / �I I_ i_ vvsv v vv -vvv \ \ \ \ � . v1 - - - / v V \ - / - v v\\ A \v v v / / / - \ \ \ \\�\ I / / - vA ti v v v V A V A V A v - -� - 2 \ V\ \VA \\�� ���AVA \\ \\\ 1 V \\ // \ \ V A A \ / ml \\ F v - v vv v V I V \ v v \ I v-- - v% v \ \vvv \\V \ II �� v V \ I // L - , } � M S \ V A A A \ - - -- \ \ \ \ ' -- V \ \\ \ \� V A L 1 \ \ \ / / I o I \ �� A \ v VA v A V \ v vvv AVA \\ g0• A \ \ \ \ v A A \ A \ \ / - BLOCK AND , -� v - / I / ) / l I i hti A \ v v v v v v \ V v V A \ - - � \ \ v v v v \� \\ \ \\ \ \ \ v A \ - I / \v-- v v \\ \ v v v \ \\ ��) 1� \ \ \ V A A \ ss V A V v V GRAVEL INLET / / / / /� SEDIMENT \ \ v v v V v v - otis - - - , v v v v vVA \ \ \\ \ \\ // C y V A \ 9 V A \ / - / / / A \ \ \ v - - - - - - - - \ \ v \ v \VA\ V \ VA / i, - PROJECT INFORMATION: \ \ v v 9 \ \ PROTECTION V / / / / FENCE v y \ v - - - V \ \ \ V A \ V A\/ / \ v \ \- OWNER DEVELOPER: \ �V A \ \ \ / I / / / / / / / / A \ _ - A � v v v - A - \ v v v A \VI V \� V \ V A \ \ YARD INLET 3.0: - - v / / / / / / / / V - v - - - - v � \ \ v - - VA V �� y\ VA VA ROBERT M. BRAME v V A\ \ \ v v / / / / / / �/ / / \ - A v I //�v� A\ / \ \ \ \ WEIRS: 534.50 - - - � vv y - v v - -- v \ - - v v \VA V 1 0 \vvv A\ v v v v - \ vvvA\\ \ \ 2863 SOUTH JIM MINOR RD 1-1 \ \ VA \ \ - v -� - / 11 I/ // / A �� -- - vv � --- -� v - A_ v v v \VA �� -_v �o���A\\ �A 1 \ \ \ V A \ INV OUT: 530.57 v v / / / / / / v \v As A - - v v V A �- =--- �w \A\ MEBANE, NC 27302 \ \ / / � / / / / / \ \ v v P v A \ \ \\ \ V A V ' / v v- / / / / �/ // / / / / v \_- v � s-- � - \ v A A \-- v v v V A v v \ \ \ ' \ \ \ - - I� / / / / ---- 1 - A \ - v / \ �� 1 \ V \ / v / // / / /\i .// /�I � ------ -� \\VAv I _ � A V v �Avvv\ J\\\\ VA \\\ \ / \ \ \ \ V A V A \ V A / - v - - / / ,� / / / / / OUTLET: � - - \ � v v v - - - A V �540 - -v - v A / \\ PROPERTIES INCLUDED IN PROJECT: \ / / - v v - v - v VA� ,- / \ 111�111 \ \ A\\\ 2679 JIM MINOR ROAD 2689 JIM MINOR ROAD I I \ \ \ VA \ b\ v \ / v - I� i� o / / /j - -- � A\\v\ v v -- V A V A / _ �� A V A /_ - III \\\\\\\\ \ VA \ s V A \ V A I -���� / / / /// //DA:0.19 AC -- � v v - - _ - v - v v A V I' I\V A s \\\v PIN 9802-59-3969 PIN 9802-59-3974 I ) - \ \ \ \ \ / i V\sVA V v - - - v A v v v - / � ��� VA \ �s V/ VA �11 \\\\ �\ VA \\V PARCEL ID# 170308 PARCEL ID# 170309 V 1 \ V A V A V - - - /-' // / // / / - - v -- v - - - _ A - - - A V A\ TAX ID 9-13-183 TAX ID 9-13-184 \ I / / ) \ \ \ \ // / // / / / \ \ v � v v � / ��v\AA \ \\�\�V\ I ` - / /i/ � \ \ \ �\ \ \\ \ \ \ STREAM I `�\\ \\\\ \ \\\ ° \� � v � \ \\ � � A \ � \ \ \ BUFFER \ \ \\ V A \\ 2.8 ACRES 3.3 ACRES \ / / / \ \ V A I - _ - z� /i / / /// /// / / / \ v v \ \\ \ \\VA V�Q� \ - ;�k / /// ' / / / / / --- - �- - A \� -- -- � A v v v h � \ \ V�' � V� \\ \ \VA\ \ V A\ \ \ / / / V A \ v v - 35 - / / " // /// / / �-' - - \v - - v sF v v I I A V I VV� \\ V V 1 \ - - / / / / /_ � \ \ V A VA � \ \\VA \ � 2863 JIM MINOR ROAD 2817 JIM MINOR ROAD / \ \ / / // / /- ---- � v A \ \ \ sV A\ \ \\ V A\ \ V ° - / / . /// _ A / \ V < v - - - - - v v \ _ A \ \ \ \A VA \\ \ PIN# 9802-59-5721 PIN# 9802-59-4690 LIMIT OF INITIAL CONSTRUCTION @ A \ _� - I / // / / l / - v A \ \ \ \� v v - - v - \ A \ / A \ \ \ \ \ /VA \ \ PARCEL ID 170310 PARCEL ID 159117 \ \ \ -/ / ///� // / / v VAA A v A - �- v� � v v v v A \ V� V A\ VA A \\ \ \V \\V' # # v v v v A A \\ V A \ \\ TAX ID 9-13-185 TAX ID 9-13-5 / TEMPORARY DIVERSION AROUND CULVERT \ �, / , - / / V A VA v A \ A \ \ \ \ / CONSTRUCTION. CLEARING AND GRADING \ \ \ - / - - - v V A v v A - A \ \\ \ \\\A V\\ \\ # # / / \ V / OUTLET: \ - - - - - - \ \ \ v v - - v v v v v A V A A \ \A \ V 1 -� A V/ \\ VA A \ \\\\ AVA 1.68 ACRES 14.25 ACRES BEYOND THIS POINT IS PROHIBITED UNTIL A A / DA:0.11 AC ) - - - v\s� v \ °z v v v v \v v v V A A \ \ v \ v\�- - � VA\ V A � VA \ V A VA \ I / / // / // , A V A -vvsv\VAs v - v v v v v v / i CULVERT HAS BEEN INSTALLED. MOVE V / v - A v v V A \ v / \ A A \ / // / \� v - Av- vvV --- v v -- - - \ V \V \ \ / / \ v vv v v v v v V A - - \ \ \ \ \ VA V A \ VA VA \ CULBERSON LN S JIM MINOR ROAD / TO PHASE 2 OF SEDIMENT AND EROSION \ M / / v v / v� vv - A - - - - - AAA \ v v - / ° A V A f- / / (( - v �v v v � \ - v v vvv\v vvv v A - - v �F v A \ v A v - - - - - - )�\ \ v\ VAA \\ \ \ \ V A PIN# 9802-58-4657 PIN# 9802-58-9583 � / CONTROL (SHEET C4.1). A V A \ / _ v I v v - - v \ v v v v V v � V A \ � - - A \ \ \ \ \ \ r \ / / \ / - Av - v -, / v vv Vvv v V � - - v v v - v v v - - �' �-' - v v b� - _ - - V A \ IA\ V A \ \� A \� A\ PARCEL ID# 159114 PARCEL ID# 159116 / / / / / -- / = h L - _ - � A VA VA A \ I "- A v VAA v vv v �� V A Sig v - v - v -A\ - - v \ S� - ' / \ \ \ \ - / / 1A w / \ - - �' - / \\ TAX ID 9-13-4A TAX ID 9-13-4 / - �' V / \v v v \ V v vv v v - v v v v - - - / / A\ \\ \ \ \ 6.01 ACRES 13.71 ACRES �� /50- � -- l� v v' v v y vvv v y v vvv vvvvvvv,; -- v v v h / / / / / A / / / � FES: 529.50 ' - - - v s vvvv A - - - - / / / \ \ V A - APRON @ FES- v A v v v v �s v \ \ v y v -v v v v v A v v v v v v v v vv -- -/ / / / -_ - / / v v v U. v v v A v A v v v \ - v v v\ ---- -- /� / /� �\ V\ \ / / / / / / / / / i I �" CLASS 1 RIP RAP: ` V- vv vast/ w v v v A \ \ v A , w yvw � v v - A v 1 v v v v v v V � -- v v v A- -- vv ,- k - - - / / / / A VA 1 A t 1 TOWNSHIP 9: THOMPSON . / - - - - \ - - v v v V� v v A \ \ v v v v � v v - - a�g_ _� / / / ) o DEED�PLAT REFERENCES: / / / / � I - 16'Lx18'Wx24"T \ v v v v � v -v-�v v \ - v v v - - - - _ - -� / / // - AA V A \ \ \ \ v� � v v �� - v v v - - - / / / %`� / / / \ - A v v V - v /v - -\ v- - - V v � � - - - - - / �ti / DB: 2823 PG: 0093 PB: 073 PG: 0293 / / � � 1 / � / �// // I � - v v v v� v� v v V� V v v � v�� v vv v� \ � - v v - -- / / / � DB: 3239 PG: 0957 / \ d / /// / / 1 1 - v v A v V A v \ / v v v v V v v- - \ - - - i/ / i \ \ \\ A V'\ r A A v v v - // / // � I � / / / / / i // / \ - - - v A \ \ \ A\ � - v A - v v v v v - - - - - - - - - - _ �- / DB: 2487 PG: 215 PB: 073 PG: 0293 - A � / / i CULVERT 3.0: / / / £ \ V \ \ - V - v-vvvv s� - v v v -- oss� - - / / // \ \ / / / / - - \ S \ \ \ VA \ \ \ \ \ \ I \ v� AA - v A �� ---- --_ --=---�i� // / /� I V / - / / 85.8 LF 24" RCP / ) - \ \ \ \ V A \ \ \ \ "> v - v v - v v - - / / / SOILS: / \ / @ 1.20% SLOPE / � \ \ \ \ \ \ \ gag- - i / // / / CnB2, CnC2, CnD2, CnE2 = CULLEN CLAY LOAM =GROUP C V \ \ I / - - -- - - A A \ \ V� V \ \ \ V A \ \ \ � " - \ �� A \ V A \ - - - - - - - -- - - /� - /\� V A \ / / / / / - - V \ \ \ \ VA \ \� \A \ A \ \ \ V v v A V A \ v v v v - - - - - - - - - �- / // RvA = RIVERVIEW LOAM =HYDROLOGIC GROUP B v \ V A ( / A V / - - - - _ v V A \ / v v v \ -- - V v v - L \ v _ - - - _ � �i� /�// � WtB = WYNOTT-ENON COMPLEX = HYDROLOGIC GROUP C ) I \ I I - --- \ V AA VA V A1-1 \ \ -v v v - - - - ------ V AVA gp� \ V / \ \\ V ASc� AA\\\ \ \AV AV�S\\\ v- ��� V-� A ���-/ / // - % - - // // i v v V ' s \ \ \ \ \ V A \ \ STREAM BUFFER v v �� ,� � ��� � - - - , - -i / /- V \ - A v y v v _- \ \ \ \ \ \ \ V A \ \ �,� - �" - _ _ _ � - - - - - - - _- - - - - _ _ - - _ - -_ - 5�� /// FEMA MAP #3710980200 K, EFFECTIVE 11 /17/2017 - v -----v A V A \ \ \ V A \ \ ) / \ ) )� /������ ---=�-���-� �- -__ --- -/� / FLOOD HAZARDS PRESENT V \ \ \ \ \ V A / / / � /� / / / - - _Vv � - �1s- - - - �� - - - - = _ _ = _ _ _ _ _ _ - - -� // /� TOTAL ACREAGE: 41.75 ACRES BY SURVEY CALL BEFORE YOU DIG... IT'S THE LAW. GRAPHIC SCALE \ I A / / / /� / /� --vv-v ��� gas-- _ - - - -i// �' / / / - - � - _ - TOTAL # PROPOSED LOTS: 33 LOTS \ \ \ / / / �' / / / - v �� --�� -- -�-- - - -510 - - ��� - ( ) V / ) / / / / / I / �j/ / /� , u / / ( / -- v - - � - - -- _ - - - AVERAGE LOT SIZE: 0.49 ACRES (NOT INCLUDING LOT #33) CALL N.C. ONE -CALL 1-800-632-4949 so o so so 120 2ao / / / / / / / / / - - - sos, \ \� - - - _ - - ; - - - - - - FOR LOCATION OF UNDERGROUND UTILITIES AT LEAST / / / // / / _ .. - \ - \ - - -� - - - - -- ' ' - _ - _ - - = -- TOTAL OPEN SPACE: 532,630 SF OR 12.23 ACRES / / / / / / / / / /1 / / / / I // / /// / / ��_-�..� ='r: _ , . _ _ - - - - - - _ - ; %/_ - - - -' WINDING CREEK TRAIL: 316.09 LF 2 WORKING DAYS PRIOR TO BEGINNING GRADING OR TRENCHING. / / - _ - - - - - - / / / / / / / /� / / // i :.:: ' - : - � - - - - - �� --� - 5i/- � = - -� - NORTH CAROLINA GENERAL STATUTE 87-102 / / / / / / / / / / /�/ / // /�/ i �' STREAM \ _ - - - --- - - _ - - - FOREST CREEK LANE: 1,186.86 LF �• - v v A ---� - /-- - / -- - - IN FEET �i / / / / / / / / / / / �/ /h�/// / / /. �i /i' v v - - - - / oog- v v �- -- - -- - - - _� -- , PRIVATE DRIVE: 1,257.87 LF (IN EASEMENT) 1 inch = 60 ft. ' ,/�//�/�/,/ / �� /--// / ///� ///// / I ���'� /� vv v_ A / �----------� �;- /� y ■ U n n n { I""IL5� C: g@ Hflo .. . Q) O C L- N W r 1:t i Cif U .I--.Na)m�j +--j � a) Co co 0 U C/) cm L0 m O N U Cz M M Z * a)a U �U)U)0- W N�(1_ J ILL. LLI IRT c � c w N w C# Z Z 12- wv Z Q U U Z_ Oe Er .J d � .. 4 ® I-� �Emmw� <� P-4 I� � I-4 1--ol P4 P4 E­4 L) I :) y) O P4 4 C/D - Cl) C) 4 ®� �o u w Iw-*I 4 10 -1 1--ol I --I w 1­--� M--I mT0 0 0 0 z p z 2 2 Z O O O 0 Z 0 0[:01: � O � U) m 0 O m w wwoCw 0 D_ m W D_ rn rn rn C) w o 0 0 0 � N N N N ao c2 co 0 0 0 6 6 LLu r N Co � m DATE: AUGUST 29, 2018 HORIZONTAL SCALE: 1"=60' VERTICAL SCALE: N/A PROJECT MANAGER: CPK DRAWN BY: CPK PROJECT NO: 17-002 DRAWING NAME: 17-002 REVIEW THIS DRAWING AND THE DESIGN HEREON ARE THE PROPERTY OF EarthCentric Engineering, Inc. THE INFORMATION ON THIS DRAWING IS NOT FOR USE ON ANY OTHER SITE OR PROJECT. THE REPRODUCTION OR OTHER USE OF THIS DRAWING IN WHOLE OR IN PART, WITHOUT WRITTEN CONSENT OF EarthCentric Engineering, Inc., IS PROHIBITED. COPYRIGHT 2019 EarthCentric Engineering, Inc. SHEET NO. PRELIMINARY SUBDIVISION PLAN P:\17-002\17-002 Drawings\6. Rev04\17-002 Review.dwg, C4.0 - EC Plan, 10/16/2019 2:18:18 PM NAK(;LL IU#J I /U,)Ub, I /U,)U'J, I /U.) I U, I n&1 14, 1 ny I I b, 15y I I / -- 530- V � � - / - / i • - - \ \ v \ �� � - - w v � � �-- v v' v J�� --� � � ,-- v - - \ � V - y Vvy - � - =-- --� V A \ : �� A - - \ - - - - - v �, - V A - ti �_ _ -77 \ - i i _ / V I V A \ \ \ v A A A \ f - �� VA \ VA �A�VA �'� A� - \ i - � 1 I I \ / / � bS, A A A V \ - V V A�- � � - ---- � _� ��,� -- A _ V A A �, � --- V / I I V �i --v v v v v -A\v v --A - - - - - \�� �� yvvv V A�Ay--v\-���--- �_ i = - // _- / - V A \ / - / / 1 V A I I I I �� / / ---V A A\V A- - -- ��075� - -��-- FS �, V A - � - - ��- \\ VA �-- VA A _-_ A�� �_ / i \ _ - ) A // /%// �v v v - � �S � w v v vw� CULVERT 2.0:�vv��� �V -- 10 �� \ i '\ V - - - v v v v v v v V A� _ _ �� - ��- \�\ \\\ -��� i V\ / //� icev -v -- ����� �- - - ���//ice- �- vvv DRIVE PIPE �� v� � - -- FES OUT: 519.00� / / i / / / \ - _ - - - - - - _ a�� �` V A \ \ A A \ \ - \ \ \ 5 / - - �- - --�-- - - - A �/ V A \\ \\ �' - A �\ / 55 v - A � a_ /�� � - - - - �- - - - \ v 28.8 LF 15" RCP AA s t / VA \ \ A -� i v - I/ \ v v v V A\ APRON @ FES: v - / v - - - - �- - 1.00% SLOPE \ - y - - - - - \ V`em\ \ - � � - / / � I I � / �/ - � � - - - - � -\ -- � � �/ 1 �L � � � � � � �� v ����A A VA�\ �Ai �� , CLASS A EC STONE: --- ,�, 6'Lx7.5'Wx12"T - / i- A vA VA \ - _ - - - / / - - - - A - - - -,, v-� -� T \ - - y ��-- _ ---_ A- VAA VAS ���-- ///��/ �' \ \ ) / ---- -- \�--s�q /�\� ROCK PIPE INLET �ss��� �- �� \ /v�v� '/' /�)V,A�� %� �� - - - - - - v AVAA - LINER 1.1C: - _- - - - - / / / / ) ) A / - _ - - �ss�- - - - �V%v V PROTECTON, vvv vv � \ \ � �_ L�� �T-�, / // '-- - - v� VA\ / / / ---- � - - - � , A v \V\ \ VA \ A - �v� v ) -- - - \ \ ✓ DA: 0.26+0.70+0.06+0.05+0.11 AC _ / / / \ - V ) / //o°A/� - -- - - \ \ JUTE NET - /// / I /------ - \ \ \ v �`'/ - - \ \ VA - - - - - A / - - - - A \ FES IN: 519.29 V/ / / /// � -- -\ \\ VA- _ - --- - //// / / / V / -- �� v \ \ VA\\\ V A APRON @ FES: -vv _) i // / / r , -�gtis V A VA A \ V - - - - - -- - - - / / / /�,� / / / \ / I� - - - v � j � V\A \ V A V \ V A CLASS A EC STONE: A - ♦ A \� � // �- -\ \\\ - i / //�a / / V - / \ V i A \\ VA V A A V A 7 �� / ) \ o / // / v v v - -v / \ s\\ V ) V )\V-- / - V \ - _ � �� \ \ o \ \ 4.5'Lx4.5'Wx12"T \ / / / v \ \ �� - - _ FES OUT: 548.13 _ , _ _- - -// i ���� \ v v \ / v� A V A ,\ \ \ V A \ \ V A \ \ \ \ \ \� i � � � A / \ s Sao \ s \ V \ s�� A / I A \ \ � - CLASS A APRONC STONE: - / /� - - - , , / ' + ) v v - - A \ / -. \ \ V A \ �, A \ V A VA \ \ \ \ V A, l I / - - \ \ \ \ - - - - - 6'Lx7.5'Wx12"T= - _ - - i i - _ / / /- - - \ \ \ \ / \ \ \ \ \ \ LINER 2.00: / / I ) - - - - - v - - - - - - - - - - - - - - / � � - ��� / SKIMMER SEDIMENT BASIN 1: v \\ \ V\ ORCCCHE COIR HECK DAM \ \ \\ \ \A I / DA: AC _ _ _ � STRAW W NET \ - - - - s� - TYPICAL) \ \ \ \C14 /� /--- - - -v -\-_----__---- �� ��/ �/ - /// TOP OF BERM: 549.50 �v h� \\ /\ \ V AVA\ \ \\� VA \V A \ ��) i - v - - - CULVERT 1.1: - - 7 -\ A �/ � -- CREST OF WEIR: 548.00 v / A V A \ \ \ \ \ � \ \ V A \ \ \ / 1 I � / / /) / - - DRIVE PIPE - v - Zi / - G / / LENGTH OF WEIR: 6' � - - v / - v I \ \ \ \ \ V A LINER 2.OA: \ \ / / I I I I I I ) / / / / /- v - - - 32.7 LF 15" RCP - �� - / �� - - DIMENSIONS ® WEIR:80'Lx25'W - - A - V - _j \ \ \ \ \ \ V A� DA: 0.17 AC / � I I I I i J) / / \ v v . Cs� 0.52% SLOPE - / y�r / A a`' DEPTH FROM WEIR: 2 - - \ \ - V A \ A \ V \ CURLEX II OR I ( / / 12 X50 CONSTRUCTION ENTRANCE /. - - - - v - � \ \ \ \ \ \ \ \ \ A V 1 I I I I I I I i � / X / ' "���'' �� 3 BAFFLES REQUIRED �_ - \ _- - \ \ EQUIVALENT ) i / / � / <�; % C 2" DIA SKIMMER W� 1■ DIA ORIFICE - - - - I \ \ \ \\ \ \ �\ \ \ I I / / �/ \ ♦ / / OUTLET TO CLASS A EC STONE: - - - v v v - A \ \ � \ IA \ \ I \ \ \ ) 1 / / FES IN: 548.30 1 / � \ \' ; ` ■ \ \ - - - - \ \ - \ \ \ \\ 1 \ \ \ \ \ I I ` o / / / APRON @ FES: \ V �� / 3 X3 X12 DEEP APRON v - v v /) / \ V 1 \ 1 \ 1 + / SIL FENCE V\\ \ \ \ \ \ CLASS A EC STONE: \ ` �,� - - �( / / 4.5'LxEC STONE: \ \ \ \N `',IY ;. / / - - - - - - \� - \ - � \ - - - - - - - - - / / / 1\ 11 1 \ I I 1 \' \ OUTLET \ \ \ \ \\ \ \ 1 �� / \ - \ \ / _ - � -_ -� - - -- \ - \- / \ \ \ TYPICAL \\ \\ \ \ \ \ /, / // II I-- i / \ \\ \ \ \ �� - - \\� � ---- / / ) \\ 1\I \ 1 \ ( \\ I \ \\ \ \� l i � LINER 1.16: ( -� - � - - - - V-- v - -v � / � A ) // _ _ DA: 0.05 AC \ V \ \ \ \\ V - -- ---sue v - --A �� v -- --- -Ogg- - / V / / A \ \ \V1 \ \ / / ) z Qs91 I i / A STRAW W�NET \ \ \ \ / A� - v -v y v v \ - -- -- -------� / / / \/U `"n \VA\ V 1\ I �' / ROCK PIPE INLET - V v v \ LINER 1.OA: - - - - v - v - - v v v \ - - - - - - - -' / A\A / \\ \ MI A A / PROTECTION / / - L - A \ \ A v v - _ v vA V A v v - / ® / V I V / / .� v -v v- v v \ DA: 0.2o Ac - - v v v v v - -- _ --- --_ -- / / /. I/ ��( \ II \,V I I I � / / � - - V A CURLEX III OR � - -� ' � - - - / I \ ,n I I / � LINER 1.2B: - �� � v � A \ � � v - \ \ v -- LINER 1.OB:- � - - / / I I I / \ - A \ EQUIVALENT - _ A - - 9"g- �i / \ \ A A VV 1 I / DA:0.26+0.70 AC � `� / / - \ \ \ - - DA: AC \ \ \ / JUTE NET - - ))) / / // / � � v V A \ \ \ V A / I / / � _ BLOCK LOETKPROTECTIONAND EL - - - /� \ I I I I I I V A \ \ \ I I I I / / i - ♦ A V A \ / i v SINGLE ROVING - - - - - - - 11 -- -s� `� / -� -� A / / I / / �-vvv - - Z, / \ I V �a ,1) �1 l«oz) se ava-arm �N / ' LIMITS OF ) / - V \ \ \ v A A - - - - - - I / V A \ / FES OUT:550.25 �,- - LINER 1.1A: ��'/� / A I � / I / - v t _ _ - - - �, , I \ v APRON C� FES: DISTURBANCE: /o A\ \ ) COIR WATTLE / � - / /i - v v v - -� ��� � / / 233 605 SF OR 4 DA: 0.06 AC I / ,� 1 �< \ / v - o / � / / DA:0.04 AC I V � � A _ -- CLASS A EC STONE.. 5 / \ \ OR CHECK DAM / / 1 / /) ,�/ / v - � / / 1 I I I h \ � _ �-- v 6'Lx7.5'Wx12"T 5.363 AC / / STRAW W�NET \ \ / - - V \ / i A � V / / - I CT38 +Q�� - - - i�+o - - - / / A \ � � � � / / STREAM, // V A V / SF 1 (TYPICAL) \ \ / - - - i / STRAW W�NET h/ V - - \ V A \ / / z / '� I / _ v r► � \' � YARD INLET 1.0: Ii k - - - - / l )� // / i / / �// Ii �' -> 5� \ / 1 / / / BUFFER ///, 11 \ V / / / i - - - A \ V WEIRS: 525.00 - ��,� - �L� -SF .�� � -✓- - - i / / h / / / / \ \ I \ \ \ CULVERT 1.2: i / -/ A / - V I I _ - ■� _ - - - � / / //)) / I I / // / / \ ♦\ \ \ INV OUT: 521.60 1 \ \ % ,3X / 1 ' / � - - - - - � --- ---- / / / / / ENTRANCE PIPE / / \ \ _ - \ �, \ ,� V I I \ \ \ �� x \ \ - - - - - - - - -535- -- i / / A / /ii�/A//� / ///­ \ 60.9 LF 15" RCP i Q A o n A ) \ \ V - - �o - - - / i / / / // / / / �/ / % /� °� A v / \ ��, v v / - v v, vv - I I \ 1 V I � / v v � _ �s _ - - � - //�/i "Z � //� / / SLOPE I /� 5 v v \ - - �/ / /// / /ii / V / C�? 0.50% _ s \ A t \ f \ / \ \ V A v A ADDITIONAL MEASURES: - - i / / /� / �// � / � V A - - - 1. ADD INLET PROTECTION _ - - I / / // / /// / A/ / ) \\ \ V A v v - - _- - _ - - - 2. ADD ADDITIONAL SILT FENCE AND _ - - - - / �i) �� // / // %cY// / / V A \ \ 12'X50' CONSTRUCTION ENTRANCE / / / / //� / / r V A A V "k / / _ - - /) ) \ / - v0 \ A A \ A- --� CULVERT 1.0: - _ OUTLETS BEYOND CULVERT - - - - / � �-- ( / //% �// �% //j�// \ ) FES IN: 550.56 / / \ v \ - - � -OC9 � - AV ))i Z- /�//� / / \ \ \ APRON C�? FES: / � V A \ ) V v V / - - � ,57.9 LF 24" RCP - - �3. RECONFIGURE SILT FENCE�DIVERSIONS - - - - � - ) J) / // / / // V A A \ \ CLASS A EC STONE: /\ / i A \ V \ \ A A ) /) / I - - 1.04% SLOPE - TO DIRECT CLEAN RUNOFF TO INLET _- - - - � �� j/���/,/ / / / /// // - 4. CLEAR REMAINDER OF DRIVE - �/ ��_ i///%/ ��j� -- / - 4.5'Lx4.5'Wx12"T FES IN: 538.50 \ V ) )) - �- - - - - - - - - - - _ �� >/// //// j, i / // //� \ \V A V A\--�� / APRON C� FES: \ \ \ \ \ I I I V III l - - -------------- / -��/ / �/ /%/ _ O/i/ //� / i _ \ \ \ - - / CLASS A EC STONE: A V A / V I I \ _ _ - - - - _ _ _ - �� / \ V A A r LINER 4.OA: V A \ \ I I JN - - - ---�� �------------ ������i i/ V A \ v \ \ , 1 V I C,I I I � -- - --- s --_ --------, �� //��/j/ i/� ��i���l s \ \ / 4.5'Lx4.5'Wx12"T \ / A \ 1 \ DA:0.18 AC \ \ FES OUT: 521.00 �- - - - /� ���% /// / // i - V A \ / STRAW W NET \ V A \ v / I A \ V A �- - - - v / / \ \ I \ \ CLASS 1 RIP RAP: - - -- v v - - - - %i���i / // �� i \ \ \ \ \ APRON C� FES: / - - -_- - v v /i i/ / / I / / \ \ \ \ \ A / I I I \ V A \ \ \ - v v v - - / -:17- %/ / / //�/ / V A V A ROCK PIPE INLET \ LINER 4.06: � A \ LINER 1.00: A \ \ \ V A \\ \VA \/ I I - - = -- - - - - - - _ - - - - - /`' /// /i �j ///// /� / // % / I \ 16'Lx18'Wx24' I -OLg�- - - - vv v - - _ / i / / / V PROTECTION �N / � \ DA: 0.26 AC / DA: 0.20 AC \ \ - v v - - - _ - - - - i� /ii ii / / / / � / \ /� +� i � \ \ \ / \ \ \ \ V / � V A\\ VA\ �- --- �- ---vA --- - - � �- /i i "Z i //' V A V - - -j- / - \ CULVERT 4.0: A STRAW W�NET \ / CURLEX III OR 1 \ \ \ \ \ \ V A� - - - v - - - -/� �/ / �/ S V A COIR WATTLE / / / - 53.5 LF 18" RCP \ / - \ os. / 1 \ \ \ \\ \\ VA V A \ \ \ \ \ \ \ \ \ \ A A \ - �� -A- vvv v� � _ �_ - -�--- _ j �1 j /o/ // D /// \ V / o / / - C� 0.56% SLOPE \ \ V / EQUIVALENT V A \ \ V \ \ \ \ \ v v - - �� j // / p. \ \ \ \ V A\ \ \ -- - \ - - / v / / / / /' \ v - / / / I V \V A \V A\V A \ \�\\ V A\ v- v- -- _ � iv //�� y /,� -�i \ v / A V , A \ \ \ V A \ V A V - s0 � v-vA - - - ,�O - - � %i // . , / - / V A OR CHECK DAM \ �� oa - - - v A _ _ / \ \ �\ V A V \\ \ \ \ v s - - - �� \ TYPICAL / - v ` v v - / / / / \ \ \ \ r - - - -- -� 5 - � -- i� �/ / / / �- - \ / / / I \ \ \\ \\\ s \ \ s \ i \ - - \ LINER 3.OA: \ \/ \ \ \ \ / / \ / / /I \ \ \ \ \ \ \\\ \\ \ \ \ \ \ \�\\ \\ \ \ \ \\\ \- - \- -- / / / i/ /�j�// / ) �� i \ \ v w - DA: a18 AC - v --v / l A \ \ \\ \ \V A V A V A\ V\\\ VA\ V - - v --- %�� // / / / STRAW W NET gbg v - - v / / ) V A \ \ \ \ \ \ - - - - /. \ \ , / \ / \ / �� oA »- -- �/ / / A A\\\ \\V �\ VA\b\\\\V A \A\ \ V A\VA \ V - -- �iy��yi��� // ��o / G / / \ , E - I �i A - � / / / 1 / I I � \ \ V A \ \ V A V A \ \ \ \ \A \ \ - ---- - -- / / � / �- / , A ) A / v LINER 5.OA: / ) \ \ V \ \ \ , \ \ \ - � v -- - - % - - -- �. `Z v V � ) / ,, ' °° � �, - v v v - / / STRAW W NET / / I I I I I 1 1 1 1 \ 1 1 V ) /� / / / / I \ ) I �70 I - _ I I I I 1 \ V \ 1 � _ �� - / - -vvv- - �I �I �I� II v1v1 \1 %/ / I � / l ) I N,, 'z3v - v �� vv �� / / l / / to / / /� III I I I I I I1 I11 VAIN I I I A v95 / ROCK PIPE INLET oo v - - - \ \ ,� 8 / / / / / ) I I I I I 1 I A I I ) I V , - � �� / �// / / / I / / / PROTECTION I I � / n� \ V - v ,� ��s \ V v ��s\ v �� V / 5 I A - / 5� / / / / \ / / / / I I 1 I \+1 +\� + /i /' / // / �' �/ / / / %0 v. A - - v1-- - v v v / / / / / / / / I I I IIII�I1 1//l II II I1�1 II ,A \ V I ///' /' / / - f I / / - v\ v v v �, / / I I I I I III 1 1/ 1/ l 1 11 1 I I \ 1+ ��� (/\.' /' /v / �/ / / -� �.� * � � LINER 1.2A: -- � � SEDIMENT / / / %�so �\ FES OUT: 538.20 - \ V v\ � v / / I � � I I I I I I � � � A 1 .� / // DA: 0.26 AC / I FENCE /�\\., / % APRON @FES: - - \ \ v v, / / % I I COIR WATTLE I I I I / III I I 1 I I / A / / / / / /I JUTE NET,/ 555 L / I I./ -, CLASS A EC STONE: - -- v v / OR CHECK DAM I � 1 I � I I I' I � I I I I I � A / � / / / // / / G / / - / I I I N - � LINER 4.00: \ \ - sf (TYPICAL) ' T7 / Z / / / 1 6'Lx7.5'Wx12"T - I l i _ - - v -- DA: 0.14 AC v v v A ( I I I - ( \ 1 � I I I I�' / / / / / ,FIBERGLASS, s�3.s0 ♦ , ' I I \ -, V A V A �.� / / / / / / / , / / . / / / / - / / 1 - v - - V DOUBLE ROVING - A V A V \ \ \ \ I � / o // //�- / / / ) I - I v v vvv �v y / / / / - - v v v AV / of ��� SILT FENCE \ V A ��,A A V A \ \ I I I / %°� Q� / / I (�, ::..: i / - � � S / - - - � �A \ \ 0p I o� v v v v OUTLET \ \ s \ \ \ A /� `. r / _ / I I 1 I v / / / - - A A\ \ \ V A A V A A \ � _,q� / ( ) \ \ \ \ \ S� \ I' 1 � TYPICAL \ \ o \ \ I j I I / 1/ - \ \iAA v� V - - \ vV A ��y ° \ \ \A /A \V A A \ \ A\\\VA\ \�o AI I I�I I I �� `7/ / l I // / � / / SEDIMENT TRAP 2: / / � I I +/ / / / - v A V\� �/I v v - \ v v A � A / - / / V A \ V VA� \ AV \\ \VA A \ VA \ \ V�� \ \ f I I ��'/ \ I �/' 1 / - v v \- M/ v / / I I \ \ \ \ \ vvv v v v vv \ \ V � /� r \ o \ -� / / / � / / DA: 0.50 ACC � LINER 3.OB. I / - / / / - - v \ / 1 �v v - - v� V A V A \ � / / \ \ \� \ , A VA X \ / VA VA VA\ \\ \ V A \� \ V A / �� • \ / / I I I / / � TOP OF BERM: 539.50 DA: 0.18+0.32 AC m / / / / V - � v - v \ V \ x \ \ \ V \ \ \ / / \ / v v A / o A V OUTLET: A VA \ \V V / \ TI / / / % / / CREST OF WEIR: 538.00 FIBERGLASS, s' / / / \ v v - - v v A V A LINER 5.OB: / / \ V A\ V`s� VA\� VA\ \ �./ \ I I / / - / / / / LENGTH OF WEIR: 4'- - - SINGLE ROVING I I I / / / / / - - - I // � v - v v \ \ V A A DA:0.25 AC / - A \ /DA:0.10 AC \ VA 4, -\ V A\ V V A� \V I 1I % \ q/ \ \ / V� \ \ \V/ V A VAV \ \VI �/ \ / / DIMENSIONS ® WEIR:58'Lx1TW / / ) ) / / - v / v -- v \ V A STRAW W NET / A V A VAA \ \ VA \ VAA�V��� \ \ \\� \\ VI II / - A / / / \ \ \ �V \ /� / / / DEPTH FROM WEIR: 3.5' _ - / i 1 , // v - \/ v v - v v \ \ \V A / / / -- \ \ V A \ VAA\ \ \ �� \ vvv VA I A \ \I VA \ nll l l � I / / )( \ \ / / / \ \ \ \ V V / 3 BAFFLES REQUIRED _ / I - ) / , - - �\ v v - A \ \ V A \ / A \ V\ \ �� VA \ \ VA \v vv \VA V A \\ \\ V/, I I / A � / II V A V V A \ \ \ \ SEDIMENT / \ \ �\ V A A s \ VAA \ \ VA vvv VA \\ -/ I' ) \ v v 1 - --� / I ti I I / / -v v v v v v � - - v1p,v v vv v vvvv vvvv v \\V\\ \1 11 / � V \ \ // vAv vv v v \ s v - v ,-� \ ---- \ \ - \ Vv� vvvv- A\ \VA\V A\\500 '- VA , \ _ A\�AI,� ��'�I V A\ v v v\\v � 1v \ \ � / _- ,�� ,� � 1 � � � �' ml � I I M I �� A \\1 F v � vvv FENCE � v v � v v A � v wvvvvv � \�� I I ��- � / \ V A V A A V / - COIR WATTLE I / % ti \ v� - - v v A V \ \ _- _ - - v v \ v v- AA \\ \\V�\ L� V A V A ' \ \ V A \ \ \ GRAVEL / / / �/ ) SEDIMENT \ \ v v v - v v v \ V - - - - - - v v v v - - v v\ v \ V / �� \ - OR CHECK DAM / v A A v -- 'Dtig - v A A A v - V- v - A A \\ \\ /�C \ V A \ k PROJECT INFORMATION: \\ \ \v v \ �� \ - TYPICAL / \ / v A \ ------ - v �\ \ \ 1-�-�� \ 9 \ V A \ / / PROTECTION \ ( ) / / / / / / FENCE \ \ v v \ \ \ v - - - \ - - - A V \ \ (, v / z - - \ \ - - - \ \ \ / \ \ OWNER DEVELOPER: J / / / \ - \ - \ - - \ - \ \ V A \ \ \ ) / / / / / // \ -- -- - v v -�- --- - v A \ v- \\ IiL-- V \ V A \ YARD INLET 3.0: - - - / - v - - v ��_ AA \ \ ROBERT M. BRAME \ / /� / / _ - A \ - - - -- A V A A - - - V A � - A A \ V--���AA\\VAV AAV\ \ \ \\\ VA \ \ WEIRS: 534.50 - - / \ / / \ �/ / \ / / / - - -� v - v - - v - - - - - v A V 110 - A A� A 2863 SOUTH JIM MINOR RD \ v -i A \ - - v --- v \ v v �- I A � \ V A - / / / / I / / /� - - -v v v A \ � -� _ - �, A - - - v V AAA �� v �����A\\ V� MEBANE, NC 27302 1 V A \ \ \ V A \ INV OUT: 530.57 v - / / / / / \ \ \ - - - / vvA v v v v spS� A - - - - A 525/� A\ \ \ \ \ \\\ VA V A � v v--/ / /I / / / // / / / / v V -----� v -\ v v v -- - SILT FENCE - \-- v�vA V \ )II I \\\VA \\\ \ \ VA \ V A \ �) / - v / / / / / / .// /A. ----- --- ✓ - -�_-- A � � �v VAA A / \ \\\ \ \� �\ \ \ \ \ V \ \ v / / - A\\v v v - OUTLET \ \ A SEDIMENT v \ / / \ VI I�\ I II \ V A A �\ , PROPERTIES INCLUDED IN PROJECT: V \ \ \ OUTLET: v - / / / / / / OUTLET: - - _ - - v - - - - VA� A \ \ V A V A b� \ \ V A DA: 0.16 AC / ° \ / / / DA:0.19 AC - - - A\\ v - - - - - (TYPICAL) V A V A FENCE _ \ vv \ V A V A / \\� \ \\\\ 2679 JIM MINOR ROAD 2689 JIM MINOR ROAD \ \ V A \ \ -. / / // /, - - - - - - - - - v - v _ w vv V A \ �A AI�VA� V�°\\ \\\� PIN# 9802-59-3969 PIN# 9802-59-3974 \ \ / / /// v / ' - v - s - - - - v A - v� V Asus VA \ C A \ PARCEL ID 170308 PARCEL ID 170309 / - - i / // � v - A\ VA \ - GRADE CBU PAD LINER 5.00:� v _ - / - v V \ \ V \\��V\\\V� \ \\\ y # # \ / 1 \ \ GRADE CBU PAD \ \ I / //// / "/ � - v - _ - v _ - - - _ v v - - v vv V AVA ` V A\ TAX ID 9-13-183 TAX ID 9-13-184 l \ 1 / / // i / / � - V A\ \ s TO DETAIL / V\\ V \ \\\\ �\ 2.8 ACRES 3.3 ACRES v '\- - v SINGLEROVINGv - \ \ V� ' � VA \ \ \VA\ V ` \\ � TO DETAIL I � /// - - � � A v � v v / �� v A v V A \ STREAM \ \\ VAS, VA V A o, \ I / \ ) I z- / /// / z � / / �- - - - � \ \\ v v \ \ \ \ BUFFER \ \ �\ v AA \\ \ \ ADDITIONAL MEASURES: A V - `� �j / /// /// \ / / / / - - - - - - - -- - \ V I I I - - - - - - - - v v � v SF � v \ V I VV\ V A V \ \\VA \ 2863 JIM MINOR ROAD 2817 JIM MINOR ROAD / 1. ADD INLET PROTECTION \ A V A \ \ 5 - / /// / / / / - - - �A w - - _ - - - - v v A \ V \ \ V \\V \ \ \ / //// / VA A ) < < v - - - v v v v v v 1-1 V A - VA A \\ V A VA \s \ \ VA NN- VA�V�� PIN# 9802-59-5721 PIN# 9802-59-4690 2. ADD ADDITIONAL SILT FENCE AND OUTLETS \ / / - v \ V\ \ v - - vv 1 \ \ V A \ \ \\ PARCEL ID 170310 PARCEL ID 159117 BEYOND CULVERT \ V A V A \ / / //// // / / v V A \ V - � v - - - - - - v v v v v A \ \ \ V A VA V\\ \ VA VA \\�\\V� # # \ � � / / - - v V AA A - - A - - v v v v v A A I \ \ \V A \ \ \ \\ \ V\VA \\ TAX ID# 9-13-185 TAX ID# 9-13-5 / / * / 3. RECONFIGURE SILT FENCE�DIVERSIONS TO V A \ A A VA ) / / OUTLET: ) ) - - - A \ - - � - - - - v v v v v V A A \ \A \ ) -� A V / V A \ \A A \ \VA\ 1.68 ACRES 14.25 ACRES / / DIRECT CLEAN RUNOFF TO INLET / V A - - - v s v \VAs - - - - - -- v A _ - \ \ \ \ \ \ \� \ DA: 0.11 AC I sr z \ - \ \ \ \ \ \ - \ \ \ \ \ \ \ A / - v\v vv o - v - v - v v v v v v v \ / \\ \ \ \ V A \ \ \ \ \ 4. CLEAR AND GRADE REMAINDER OF �� V A �i / \ V ) - - -�v - - - - V A A \ v v v V A \ / /, v -- v v v v v / _ / - v v v v - - - v - v - - \ \ V \ 1 0 A M - A / \ V A\ V v \ � � / / \ / - � - � � \ \ \ \ \ v VA V A \\VA VA \ \� CULBERSON LN S JIM MINOR ROAD CUL-DE-SAC A \ \ \ / v / / v - - - vv v vv v - - - - - v v v v F v v v V A \ \ \ \ \ # # \ \ V11 \ �� / / ( - A -- v v - \ v vv �v v A - - - - - v v v v v v V A \ -\A _ _ - - A � VA \ \ VA \ \ PIN 9802-58-4657 PIN 9802-58-9583 - / / / / \ \ \ \ \ / / � / - - - A- v - v / v v Vvv v - - - v v v v v - v A v v v - - -- V A \\ \ \\� A \� /\ PARCEL ID# 159114 PARCEL ID# 159116 / / i - A \ \ _ h - _ - vv v v v v A - - v v ss - - --�-- -A v \- v °� - / ) I \VA \ \ V A\ TAX ID# 9-13-4A TAX ID# 9-13-4 i A A A � v A- Avv-- --- e V --- vv A v v\ S \\ \ i / / / / ) V A / FES: 529.50 v A v v v - v - \ y v - Vv v v v v y - / / \ \ / v v v v- v v \ - v vA- v - - - A - v v v - v - v v \ - - / / \ \ VA \ 6.01 ACRES 13.71 ACRES h / / / / / - / / / I I / / / A A A V A - A \ - - V A - - - - - - - - / I \VA \ APRON 9 FES: � - A - v - - rs v V \ � - v - vv v - v � v A v - v - v v - / A / / / / / �- v zV v v A \ \ v - v v v - v - - - - - v - / - - V A v v - - -, v v - \ v - - v \ - v - - - _ - / / I \ \ \\\ 9: THOMPSON / / a CLASS 1 RIP RAP: A v vA V - - \ \ V - _ of v vv-� v - v v v - v - - v - v � v v- - - / \ 1 A t - - - - - -- / I \ - � \v v V v v v v v - - v - - gig_ -� / / / / / ) o DEED�PLAT REFERENCES: / / / / / ) / I I 16'Lx18'Wx24"T A VA v v v- V \ V v v v v v v v - v v - - - - - - _� VA \ \ V A - _ h N - b - - ti DB: 2823 PG: 0093 PB: 073 PG: 0293 / / � I 1 / � --/ / / 5� �/ / /I - Av v , vv V � V v v \ ,� - � v V vvv �v v-__ - v A - v -��111 III- ---- - -- % / /' DB: 3239 PG: 0957 / / // J I I ouTLET: v v v v v v v _ DA: AC v A A \ i � v - - - - I I \ / / / \ v \ v\ \� v\ v v oa v - -- �/ // / 1 / / / / / / // / \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \/ / /� / - - /� i DB: 2487 PG: 215 PB: 073 PG: 0293 /�-/ �/ CULVERT 3.0: / / / _ / / bF v A \ \ \ \ VA \ v A V A ( / \ v V A v -v v v v - -- ---- o�S� �_ _ i / / /� \ I \ / / / \ \ - - \ S \ \ \ \\ \ \ \ \ \ \ I \ \� \\ \ - \ - -- - - - - _ - - - - - - - _ - -- - // / /� 1 V / / / 85.8 LF 24" RCP / ) - \ \ \ \ V A \ \ \ VA - - v v19- v v - - / / / SOILS: - - _ \ \ \ \ \ \ - - _ _ \ \ \ _ - _ _ _ _ _ _ _ _ - _ / �/ // / CnB2, CnC2, CnD2, CnE2 = CULLEN CLAY LOAM = GROUP C // \ / / �i- -V A A \ V A V V / / v V ) \ / / CCl� 1.20% SLOPE ) ( ) v v A \ \ V� V A \ \ VA V A A \ \ \ \ \ v v�� V - v v A vvvv - gZg- -- - - - - �� / ///� / � / -� \ \ / _ \ \ \ \ \ \ - \ \ \ \ \ - \ - - - \ - - - - - - / // RvA = RIVERVIEW LOAM = HYDROLOGIC GROUP B v \ \ V A I ( // / I I I / ( 1 / �A - v A \\ \ \ \ \ \ \ \ V A \ \ \ / - v v \ -- -- V v -- v L v - - - - - -�-� �/ / A A V A / ) / \ - - - SF - - A \ \ \ V A \ VA \ \ \ V A \ \ s \ \ V i v v A - - - \ - - - - - - - - - - - - �� / \ \ - - v V A V \ v - - - - - v _ ---�',/ WtB = WYNOTT-ENON COMPLEX = HYDROLOGIC GROUP C v s� A \ \ V A � V \ - - -- - - - - - - - �.�� // / � 1 1 / I - - \ \ A s \ \ \ \ \ V A \ \ STREAM BUFFER v - �� ,� - - - - -� - - - - - - A - , _ �i v /i V \ I - A- -- _- \ \ \ \ \ \ V A \ \ - I �" - _ - _ - - -- - -- - - - - - - - - - - 520- - - - _ _ - - _ , - 50' /// � FEMA MAP #3710980200 K, EFFECTIVE 11/17/2017 1 - - v -----v A V A \ \ \ V A \ \ \ ) ) / \ ) )� /������ -_=�-� -- -� �- - -__ --- _�-�,- - FLOOD HAZARDS PRESENT \_ _ _ _ _ GRAPHIC SCALE vv ) v vv vv vI v �� / /) /� -- „--� - ��; - - - --- _- _ _ _-- - - /�. V \ \ \ ) A / / � � / / / -�- � -- Disc - - - -- - - gtg-- - _ _ - - - -- _ - - - - � , �/ Z� TOTAL ACREAGE: 41.75 ACRES BY SURVEY CALL BEFORE YOU DIG... ITS THE LAW. 1 I / / � / - - - - - - - - _ _ _ _ - - - _ _ _ _ - ��� \ \ \ / / / / b / / / / / - - -� - - � - - - - - - TOTAL #PROPOSED LOTS: 33 LOTS \---�-- V - - --�- - -, - - - --- - - � _5�� _ �� �i ( ) V I ) / / / / / 1 / �// / /� /6 / / / - - - - � = , -- _ - - - _ AVERAGE LOT SIZE: 0.49 ACRES (NOT INCLUDING LOT #33) CALL N.C. ONE -CALL 1-800-632-4949 so 0 3o so 120 2ao - sos, - - - - - - - - - - - FOR LOCATION OF UNDERGROUND UTILITIES AT LEAST / / / / / / / / / /// j / / / / / / �. - • • _ - _ - � - -� _ ; �� = -- � � _ - _ - _ - - �� TOTAL OPEN SPACE: 532,630 SF OR 12.23 ACRES 2 WORKING DAYS PRIOR TO BEGINNING GRADING OR TRENCHING. / / / / / / ,/ \ \ /,� // / �- �..� - - - - - - - - - - _ �� = - WINDING CREEK TRAIL: 316.09 LF �/ / / / /� /� / / // i �. - �4 �' - � � � - � - - - - - �� i_� - 5i/i i - - �� - NORTH CAROLINA GENERAL STATUTE 87-102 / / / v / / / / /�/ \ // /�/ i �' STREAM \ - - -i ��� - _ - - FOREST CREEK LANE: 1,186.86 LF - v -A ----� -_ - /_ /-- �-- - IN FEET �i / / v / / / / �/ /h�/\/ / / �. �i%' v v - - - - \ oog- - - �- % �� - _� % , PRIVATE DRIVE: 1,257.87 LF (IN EASEMENT) 1 inch = 60 ft. ' ,/� � ,- v �� i-�// / //// ///// / I ���'� \� -v v_ / / �,-�- ----- �_� 7 1 4 i nDnn �J U IlnnII�u�u�nn�luIulnnIllI 5 g O �o .. 9 ■ Q) O C L- N W r"I " (z U uj �Nmm@j +--j � a) Co Co 0 U �(uL m O N 1--� 1--�Y U �Umm Z -E * a).. C U a)a)0- Q) � m c cz L- W .. 2 N��L.LW J IRT cc � W N W C# Z Z I� WZ Z Q U U Z_ Oe E .J d � .. 4 ® M-IIIII�I IIIEEEwIIIIII <� P-4 I=IIIIIIIIIIIII II I -I I=� P4 P4 x y) 4 o � o W I- W �+ r� � F■ 04 w IIIIII m�U U U U z O z W oC W � 2 z O O O 0 Z 0 U) m 0 O m w wwoCw 0 D_ m W D_ rn rn rn � W o 0 0 0 � N N N N Q 00 co co 0 \ 0 f f � 0 0 0 L>LJ r N Co � or DATE: AUGUST 29, 2018 HORIZONTAL SCALE: V=60' VERTICAL SCALE: N/A PROJECT MANAGER: CPK DRAWN BY: CPK PROJECT NO: 17-002 DRAWING NAME: 17-002 REVIEW THIS DRAWING AND THE DESIGN HEREON ARE THE PROPERTY OF EarthCentric Engineering, Inc. THE INFORMATION ON THIS DRAWING IS NOT FOR USE ON ANY OTHER SITE OR PROJECT. THE REPRODUCTION OR OTHER USE OF THIS DRAWING IN WHOLE OR IN PART, WITHOUT WRITTEN CONSENT OF EarthCentric Engineering, Inc., IS PROHIBITED. COPYRIGHT 2019 EarthCentric Engineering, Inc. SHEET NO. PRELIMINARY SUBDIVISION PLAN P:\17-002\17-002 Drawings\6. Rev04\17-002 Review.dwg, C4.1 - EC Plan (2), 10/16/2019 2:18:23 PM F'AN(-LL IU#J I /U,)Ub, I /U,)U'J, I /U.S I U, I n&1 14, 1 ny I I I 15y I I/ PROJECT INFORMATION: TOWNSHIP 9: THOMPSON '\ b I i J v v v v - - - - - _ � - �� ��� � _ �-- - _ A� V` ��� � -_/ _ _ _ - '-'I**---,- --, - DEED�PLAT REFERENCES: �_ - - \ v �A - - -�\ v vw v - - _ - _ / I I I - I I I �' -9kS\ \ V , -- A \ V A vA _ - -V - \ V� \ VA \ \ ��� _ -- A DB: 2823 PG: 0093 PB: 073 PG: 0293 / ) V A A I v � �/ - vv Vv -- v - v - - Sp- � � Z- - _ \ �\ - - - - vv v - \ \VAA v � v v � - - - - - - - - - - F �- - vv z \v v v vv �_-- OWNER�DEVELOPER: A v - J)) \ s \ \ - - - - DB: 3239 PG: 0957 \ �/ � - v v v - -� - - � s �o v - v V A OAS � � � � �\ \ � A \ -- - � � ROBERT M. BRAME / u - v A - - - - - v v �� - v v - - - - - _ - _ v \ / / - \ \ - � - - �\ - - - \ \ - - \ \- \ \ \ \ \ \ \ 2863 SOUTH JIM MINOR RD DB: 2487 PG: 215 PB: 073 PG: 0293 V \ �� / j j / v v V- - -s - - _ -��-\ �v v v� v v� - = V V A - - - - - - � - - - - - A - - V \ \ V A V A / v v - - - A - - - -� - �� /� - v v CULVERT 2.0: �v v-\ VA - - -/ 51� MEBANE, NC 27302 - V 1 A // � v v - - - - A- -- - - - -� - - -�/ v v v - - v v DRIVE PIPE - v �� - SOILS: \ / / / z- v v - - - - - v -///- - v v - \ \ \ - - - _ FES OUT: 519.00 1' - - - - - A vv A v 1 �iM - / / /�� v - - - - - - -� - - - -- - -v �/ �Vv v v 28.8 LF 15" RCP V�A v 'v Wit- - APRON @ FES: tl 1 CnB2, CnC2, CnD2, CnE2 = CULLEN CLAY LOAM = GROUP C \ / - - - - -\ - - - -A v / v - @ 1.00% SLOPE v A V A \ ��s - '�iN '� PROPERTIES INCLUDED IN PROJECT: _ - / I I \ - � / v - - - - - v \ -CLASS A EC STONE: OR Rp y� 2679 JIM MINOR ROAD 2689 JIM MINOR ROAD / / �� - � � - - --�� \ '-� ��A VA� \� RvA = RIVERVIEW LOAM = HYDROLOGIC GROUP B - - d` PIN# 9802-59-3969 PIN# 9802-59-3974 - - - / � - - - v v ��� ( � r \ v WtB = WYNOTT-ENON COMPLEX =HYDROLOGIC GROUP C �, \ - s, -- s s - _ y L� - \ - - - -- _�_ r� \ 6 Lx7.5 Wx12 T --1 PARCEL ID# 170308 PARCEL ID# 170309 / ( - - sv v A\� �� �� --� �- \ w°' A # # FEMA MAP 3710980200 K, EFFECTIVE 11 17 2017 - - / / / / / \ - - _ -- - - �Os �- _ - - _ - \ \ \ \ \ \ \ \ \\ \ \ r _ \ �- _ TAX ID 9-13-183 TAX ID 9-13-184 # / / \ s v�AV A \ \ �w vvvv ����0 �� w V 2.8 ACRES 3.3 ACRES --- / // / 1 A ---- --- -- �V\ \ \ v�-v- - --/ FLOOD HAZARDS PRESENT / / v v // \ \ \ \ \ v v / /\V A � J I /----__ -- __ � v i \ VA V A � � � A \ � �vvvA � o ) / TOTAL ACREAGE: 41.74 ACRES BY SURVEY - - - - / A / - - - - - - - - / v A \ FES IN: 519.29' V-- - v �/ / ( I� \ 2863 JIM MINOR ROAD 2817 JIM MINOR ROAD / / / / / /� - - - - i A \ VA V \ V A APRON @ FES: vvv / PIN# 9802-59-5721 PIN# 9802-59-4690 TOTAL #PROPOSED LOTS: 33 LOTS // / / / A / - - - v PARCEL ID 170310 PARCEL ID 159117 AVERAGE LOT SIZE: 0.49 ACRES NOT INCLUDING LOT 33 - / h� \ - / A�A \ V A V \ V A CLASS A EC STONE: \ V A A V� TAX ID 9-13-185 TAX ID 9-13-5 TOTAL OPEN SPACE: 532,630 SF OR 12.23 ACRES _ - /j `' �� I - A \ o \ \ \ 4.5'Lx4.5'Wx12"T o ) / X -� I / # # _�/ /� / V v v v \ / �v / \ \\ \s�\\ VA \\ V� \ \ V A V A s \ ��/ BRANDYWINE DR 1.68 ACRES 14.25 ACRES WINDING CREEK TRAIL: 316.09 LF - ��/ v \ \ \ \ \ \ \ V A \A V I I ` \ \ �O FOREST CREEK LANE: 1,186.86 LF _ �� - /� �� / v \ � v \ \ � / -, 1 \ \ V A �A \ \ V A VA \ \ \ \ CULBERSON LN S JIM MINOR ROAD PRIVATE DRIVE: 1,257.87 LF (IN EASEMENT) - _ / ��\ - - v \ \ \ \ V A \ \ V A V A / A ��, PIN 9802-58-4657 PIN 9802-58-9583 - - -- - _ / v v I \ \ / \ \ \ \ \ s # # - - - �/_ ,% ) � / -- v v--- � A A \ / /v \ \ \ \ \ \ \ VA\ VA\ \\\ \\ \� N I I I y� i PARCEL ID# 159114 PARCEL ID# 159116 - - - - - -gtig� - v V A / \ \ V \ V A \ \ \ \ \ V / TAX ID# 9-13-4A TAX ID# 9-13-4 � _ - - - - - //��� / �i - / / v v v \ V � / V 1 1 \ V A \ \ V A \ \ \ V \A V A \ \ \ \ \ \ ) / I .p 6.01 ACRES 13.71 ACRES _ - - - - \ /� //i/ \ v - - v v v � \ \ \ \ \ \ V A V A I I I I - -- CULVERT 1.1: - ---/ �, %/� - ;� /� � - v v v vv \� 1 \ \ \ V A \\ \\\A \\ \ VA / p - DRIVE PIPE -v / // r.�i / - A -� v v vv vim- v / v V A \ \ \\ VA \\ / / /� -v 32.7 LF 15" RCP v ��� Z - � < i� �A --- - A vv v o v v \ - v \ \ \ \ \ VA A\ \ �\ \ I I I I ) / �p fie' / / / \ \ _ �. I ` \\ \ \ s� \ - _ \ \ / \ - C�? 0.52% SLOPE 55ct/�� / A �°�\-------- v v s \ \ \ �� \ \ \ \ \ \ V A A \ \\ \ \\ V \ A // SITE �� \ / \ � / i -� I A -- -- � vvvvA -v V -- -v A \ s \ \ \\ \ \\ \ 1 I I 11 �JQ- ( / / ✓�� // A \ � ) I ----- v� v vv - v - v \ \ V �A \ VA \ \ \A VA\V A V\\ 11 I I I I // -� v v v v / / v;s� v- vvv - - - - -_ v v vvv vvvv\vvvv v v vvvvv v v�IIIII��Ivvv / / FES IN: 548.30 � - � / / / APRON @ FES: � � \ \ \ \ I / / /I Il - V -- -v v �', "'�- - -� � � -� v vv � ) A \ V A \ - �\ \\ \ \ V V 1`�I 1 ( / \�\ V\11 VA V A \ \\ \ �, / / CLASS A EC STONE: f� � \ \ v ( / / � A -- -- v v Vvv v A v vv ------ - / / \ \ V A 1 A�\\ \ \ \ \ A VA NCB, u / 4.5'Lx4.5'Wx12"T � �rf / � A \ 1 / -- -- -- - v Vv v- -v vA -_ - �/ �/ A�,�\�1 V A\ VA�\ V1 VA \ V Al IIII �'yS / \ / j\ i FES OUT: 548.13 v �� \ V \ \ - -- ---- -- � v- -- v -� v � ---- / / \ �u� �/ \ \ \ V A \ V A II 11 4 �,j, / I / V / APRON CAD FES: \ V A - - - - v�o�s - - v v v v v - - / / \ �'\ I \ \ \ VA\ V A \ \ \ � / o CLASS A EC STONE: A \ \ \ \ V - - - _ - ­:�- v - -- v A v - - -Ogg- / , V \ �A l ss1 / \ � v - - v v - v - - - / / / / \ \ o s \ VA \ A 1 \ I \ \ \ V \ v v v v v v \ v / �10 � /� V 6'Lx7.5'Wx12"T > A \ \ \\ V A \ - v v-v v v v , vv � -- --- -- ----� / / \\/ / \ \\ \ MI \V A V VA \\\ L. /� / // � -� �, v v- v \ v v �- -v vv - - v I0 I �11v I I v v VICINITY MAP ' / v- - ,--� ' - - v v v A \ V A --� vv v v v - v v \ - - - - � / / / l� � \ � I I I \ b V I I I A / v v v \ - --- /\ \ \ \ V1 I i =2,000 � / / � - �� v � v\ \ \\ V A � v v v v� v v v v v- v ���� � � �/ (/ j \ I I I I V A\� I I I I V / / - v \ \ \ - / - vv v v - v- - - / -�� /(// //'/ /v >.7- M --v -- A V A A \ V A / / v� v v v� vv - _ �� / \ \ I \ I I I IIII \v V VA / - - A A \ l / - \ - - - ---7 i / / � / / -� �� \ \ V A A 1 / vv \ - - - A\11 II I l«oz) Cl?ava-arm ON FES OUT: 550.25 / / / // �3l V� A \ V A A \ / \ - - - �� _ v v A V v v - - - i / / / V A V ��4 / A-- . --,� o \� \ V A I I / i PRIVATE \/ / �v vvvvv� �� - v - ---- /��� 1 I IIIV� II II�III I I is �� APRON C� FES: / a CLASS A EC STONE: / / / v� V )��) /STORM EASEMENT / / v ��c ��� ��o j / A / / I I I I �° )/ A /' - 6'Lx7.5'Wx12"T , / / - -- v (� �� s (10' OFF SYSTEM) / / - _ _- _ - _ _ i / / J / STREAM "I) \/ / \/ \ - \ \ � / � v V I I I I� I I - - - r�o - f -- A / I � / /) / � BUFFER ///%//// / V � - / - x YARD INLET 1.0: I . - - - - +�a� - - -/ ' - � A h i i � / �-, V - v V A �. ,*'- T . - - v v A � V A \ \ WEIRS: 525.00 / � � - - - - - - - - - � / V A I I , -' / // / / % /// 1 V \ \ / - - V \ i - - -� - / 11 / //�/ // \ \ \ V CULVERT 1.2: � i / V�/ � - � v A \ 1 INV OUT: 521.60 I _ - - - - v _ - - - v / // I\ I / / V / \ ENTRANCE PIPE \ �k �R AD IDE ��-_� V A \ \ J \ \ I �I I V ` ` ( 1 ( i It I ,-� � - -- - � � --- --- // ////�/// /_) / /�//� , / V / \ , \ i - - - - - - - - - - / / / / // 60.9 LF 15" RCP " \ D CH \ �• o \ \ \ v - - - -s35- i / A// / / /// /// . @ 0.50% SLOPE /� GJ \ \ v A v - - - - - - - - i / / / \ \ \ .� V / - / // / // / / // v - s vv \ v v I v v_ _ - - i/ //i//v/ii i / / \ � \\ / V A\ � \ \ \ � - _--- - - - --- - --- �i/�/ /moo///// / / // i \ \ / \ / V - A \ V A / v V v - A �i�� ice/ ///� // // / / // // \ � / / > / �'�� v Visas_ _ - -- - - - ----�� A \ /%zz"Z, , / j j // \ \ \ - V. \ \ \ - - --- -- - � l - � V \ \- Q (/ /// // /\ �/ // ✓ FES IN: 550.56 / - - CULVERT 1.0: - 3 - - - - - - �// //// / / / i \ V A A - C� 1.04% SLOPE \V �)i///�// / / / // V A , 57.9 LF 24" RCP - - _ APRON C� FES: / / v - . A \ < V v V / / - �� - - i - \ \ CLASS A EC STONE: /\ /. �i i \ \ \ \ A l l I l - -- --- ------ -- - / /�/ \ �l I --- - -_ - _ --- --_�/ -- %� �ii,// / // -- / //� / FES IN: 538.50 - - -sag- - _/�, /// / V A � \ 4.5'Lx4.5'Wx12' T 3 \ \ i-'f / I '- - �� � \_ V \ -- l - - � �/ �� i/// // / / / / / \ V� / APRON C� FES: V A \� �I I I �) / / PRIVATE ------------- � //���jA/ / �� \ v y v v 1 I vvICI - - \ \ V AV �:' CLASS A EC STONE: A V / � STORM EASEMENT- - - - - - - - - %�i� �i //// / / i // \ \ \ I - \\ ------------- /�% / / / ,//�,// \ �, \ \ \- �'�� /� 4.5'Lx4.5'Wx12"T \ I V A �A \ \\ \\ I I , -- ( ) - -- �zs------------ - ���'-- �/ �/ / ,l v s __-- -- - v 5 vvv ,1 ---_- - �-v, - ---- /,;�;�/„ ,-,/. 10' OFF SYSTEM - �/ //% / / / i \ v - _ �, / \ v A �� I \ \ \ \ FEs ouT: 521.00 - v % i / j / / . •j \ \ \ \ \\ CLASS RIP RAP: A - - - - - - - - - - - - - �� 1 v \ �1 \ \ \ \ \ - - - - - - i /// / i /// // / i / V A V A �N \ � /� A \ \ V A \ V / / / o \ 16'Lx18'Wx24"T�V A V A - / / 11 / / / \ \ \ MONITOR VEGETATIVE SWALE FOR - -- / / / / / / / / \ \ - - - - r \ CULVERT 4.0: \ \ \ / / \ \ \ \ \ \ =SIGNS OF EROSION DURING FIRST _ - - - - - /� .' / -- \ b / / I \\V A \ V A\ \ \A\V \\A\ - - __ - �--��/ / //o/ c, // O // V _ TWO YEARS AFTER CONSTRUCTION. _ i \ V \ /� / \ \ V / A \ \ \ \ \ V A \ \ V A \ �\ \ \ IF EROSION IS EVIDENT INSTALL - - - . - - �� - / // // /i / \ / / \ / / - �\ // I \ V \ \\ V A V \\ \ V A _ \ - ///�a/ o./ \ V / / 53.5 LF 18" RCP \ \ s / / % // / // 11 / \ v • o / - - -� ®0.56% SLOPE \ V A �/ / / / / V \ V A \ \ \ \\ \ \� \ V V A �- - - �� / % /// /// / / \ V v v► V / - 2 - v A A v - / V A A \ \ V A \ \ V A \ V�\ \\ \ \ \ TURF REINFORCEMENT MATTING - - - - - - i / //��/ /� / . - /i / \ �� / �- \ \� \ \ \\\ \ / / \ / / \ \ \ \ \ \ \ \ \\ \ \ \ \ \ \ \ ALONG SWALE AND REVEGETATE. - �y _ % 50/ // / // j %%/ / \ ,' \ j / \ V -v r / / / -v \ v v v \ V A V A\ \ \\ �,\ \� \ \ \VA A\ \ \ \ V A _ - _ i � / / v \ v \ \ - - A/ 1 \ / \ � - - :777- - - %V / v \V A ► ---- , \ \ �/ i�-� - ��� �sss ���� -� / \�-/, / / /� \ I I IV \\ \\ \ \ \\ V A\\�� VA\ \\ V A ���� - % %� /�j/% /� �J / / \ v ��- /�\ V A V I -9*9- _ � v - v - - / / . / / / I \ \ V ,v Av \ 1 \ VA VA\ \ \ \\ � - - - %�%�"� / o� /.� / � � � � \ � - �/ // 7 J \\\ \\V \\VA\b\ \�\\ \\A V A A\VA \ \ - _ / �- / , G / �v 30 A \ \ � - . ,I",- - "+o - - - - _ \ \ - / / / I I I \ \ �, A\ \ V A V A \ \\\ \\AA �\ dos - - � -/�� % � / / + � - % v // // ./ / / 8 \ \\ \ \ ) VA \ \ - / �j - �Q / / � / �� - �v �.- / \I \I \I V A\ \ 1 1 \ \ v� v�-- - ��� I / /' / / v --� \ vz z,. ' I - / / / // � / I I ) 11 I v �� v 1 vvv vv _ - - _v• I ,o - - \ - / / I CI ,� ,IIII I 1 1 \ \ \ , � � - - f % = - , l I , -- �v vv `v -/ �� iv // / � / 1 I I 1 V I I I I \ v4ss_-' I� / / / v / �1 0 -- �, �,v�_ 1-1 8 i l /) �ll11 ��,IIIII III I� v1 1 1 v;- ;'� �� �j ( \ I '� -/ I Z �/ I IC / vvvY� \= .v vvv /�, l / l // / �� �I1 �I �I�y,I 1 II ��� i / / / / / / I I / no � - \ s, �� / / / \ / / ./ / I I I I I / I V A V Ai /' . / / / / / �_ , �/ �/ �' I t xo v -.- - v � suev ' �°� / / I I , / / I I I I 1 1 , v � I + v I� �� /I / / \ I ] - A - V A v � V / / // / I // I I I I1 \ \ ,/ / \ / // // �� � - I / xs : �- \ FES OUT: 538.20 - \ \� �\ V v / / / / / I I / 9 / I I / / / / I I I I I � I V A \\ \ (/j / • / / / / // �h� / �\ � i / I / A / ��- � APRON @ FES: - - - V v v / / � / / / I I I I I � I /I / / I I I I I I I I I I I I� I/ / / / / / �a j / / i / -��� / I I I ./ - \ -, CLASS A EC STONE: - \ v v v� v / y\ I 4 / I I / 61() I I I II / / / // /� 555 I 1 � \ � , I I I II� � �/ / / v v 29 I I / I ) 6 Lx7.5'wx12"T � v v v v -- 9�00 � I I I I \) I, I I I I I I I I I I / / // / / // / i / - - ) I / \ \ _ - \ - A 79+3350 / I \ I I / A• / / / v v v I I � / l / / � // / / / / / / / / / - / - I I 28 / PUBLIC v ----� - v v v �� I I o / �•� / E / - � I 19 y vvv / �I j �I \ \\VA VA\\\ \�VA 1 I I I I %//� �,, \ /. /\ / �/ //I ,C / j / / / � / / v A . v v v � �v ILoo I \ -�\ V \ \ � l I I / i • Q ::..:" / / / / - v ./ I I o/ STORM EASEMENT \ vA \ v �s v V v v v v v v v � I. I I I A�\ V A ,n � A V A V I V" \� . A I -�] ,/ �� I / - � ) 1 I I / TYPICAL SYSTEM, � VA V V v /V A v v v A \ \ \ \ \ o \ \ � I I / � / / / I / ) • ( / / \ /- �- - v v � �--�\ \ V A AA \\ \ \ VAS A�V\\VAs., \ �o \ I � I/III 4r / / / / � 1 / / / / / / �- / / I +/ Y / A�.�', � -� v v v �� A\\ \V A \\ � V A A s \ �J - - / / v /�, v. v v / I / \ \ \ V A\ \ \ 1 + /�' �P. / / I f ( to I / / / - , - �, 1 V / / �\ \/ vv v V A�\ \ vA \ \ VA \ \y \ ./ / / / // /v ��� / /, / / / / / �v- v �� v� vv -- �I vvvv '� / x� / VA \ \ .\\ vvvv wv�vv vvvv v v Al\"�- II �// �j• 1-1 v A \ v v v V w \ - � �5 / / / / - \ // \ \ \ \ \ \ \ / / \\ \ \11 \ \' - \ \ \ \ I / /v / - / / 1 �/ 18 v v v / �� / v v \\ vv v� � v v vv \ \\ \ \ y / .. \ / � V / / / �- v A/ /� -v v v / vvv v v vv / V v I / /, � � ---/ / I I ( / / /�/ -- //�� - v v vv v vw v , / k ,\�� I v V A �wvvv�� v �ww� vvvv \� V�VAA\IIII �/ v �' v V 1 / / �v � I / -- �v v v V v v v v v �-, s/ / / v v v v v vv v vv vv v V - V I / �. V v / / I I -- vv v v v v v v- -/ / - v �vv� v v I- /v�� v v� vv v� A\\ I I/ \ /\ v v v / - \ 11 N 1 \ I �� \. v v - v v v v v v v v - -/ / v v � \\ ,A\ \1 1 1 - - v - v v v - _- v �x v V v v v vv v- v v v vv vv v \\ \� \ I I I v A A V �I - s v v v �--�- vA \ - - - / � \I + ° o A \ v - - v - - v v AV A\ \ ,50 0, v v V A v v AA V A /- / )TI // - V/ \ -- -- v� v17 vv --- v vv vvvv-- ��vvv vv\ \ v. \ v v v v� \ ) � I / � -- - / // // �)I//�" \\vv - vv�� v v,\ /�-�otig- _- - tv v v v v v - vvv vv A ))vz�\ \ v \ v v v v \/\ I / 27 ) �` / I / / / l / \ \ v v - v ---- - . - v v v�-� -vvv v \\\ \\ )l/ ��(��V A v� \ v � v im\ s \ \ i / / / %/ V v A V� v A - - 15 v v vv v v v V A \ �- v \ v / v v v.v A vA A \ 26 v�v / / / / \ / A �/ v _ v v -- -- 4v� -----� - - - . v v v �- vv I �� v� vv V �'v \ \ \ \ VA A \ / v / / / / ��/ AV /�/ / \/ / \\ -- - v� v -- -- - �� - V v��\ V10l - �� \ \ - - - v A v v v A � \ v \ L �� � - - - \\\ \\ \ \ \ \ YARD INLET 3.0: / / / / / \ - - - / v � - � v v \ \ _ v,'t 1 \ \V A V , \\ \ V A 25 \ i - - / / �� / / / / / // \/ / f- \ \ - �-- \ \ v g �� - v ' \ - - - v v V A \i25 - ��,, �\ WEIRS: 534.50 A V A v --- / / . / / / - ��. v - v \_---- -v v AA\ v s 1 III , A\ V A INV OUT: 530.57, - v / / / / / / v A - � A��v v /v - - - - �v V / \ \\ �/I I \\\ V A\ 1 v\\ \ \ V AA VA A \ V� \ i - / �� / / / / X/ i vv V A\\� - - \ v v �� vv v v 1\\ \V \\vA / / / - v v - - \ �54J v v vvv / I v v\ v \ \ b\ V A V vvV //� o / \ /�i/i/ /// y�o�` v� - v\vvV�� -v --- -v �. v - \� v vvv, \/ 11) N\� \vvv '-� \� VAA s�VA \ \ - / //�// ///v -- - - - \ �v�� / - A`s v 11 ° \\\ v� \ , A \ / / / � _ MONITOR VEGETATIVE SWALE FOR L \ - v�\\ F V �A �I 1 \\' �\ \A 'os %' / �i �/ /// // / - V- - GRADE CBU PAD \ V v v v - / - A V A . A \s \ V A 1\�/V\\\VAN \ \\\\\\V v v \ i / v - . \ / /� ) \ \ GRADE CBU PAD \ ) - / /// / - SIGNS OF EROSION DURING FIRST -� - _ � v v v- ( / v v VA \ VA I \ , \Av A \\V V v / / // / / / � - Fs� TO DETAIL A v v v / 5- \ vA \\ STREAM \ \,\ / / �� TO DETAIL \ �� / , / TWO YEARS AFTER CONSTRUCTION. / � v \ v v / \ \ \ ,BUFFER \� AV `V, �- , A\\V v I ) / / / ( \ V A V A I I I / /� /i � - - v \ ( 12 \ \ \ \ \\ - \ \\ PUBLIC IF EROSION IS EVIDENT, INSTALL - - - v \ v v vA \ \ A \ \ \ / �� \ \ _ - �` / / /// ' / - - - - - TURF REINFORCEMENT MATTING - - v v v v s v \ V - , \ V A V A \VAA\ VA \� A\\\ \ / % / / / / � \ v \ 5 - � \\ STORM EASEMENT, / - - - - - -� �� 1 - V A \ V A s V A \ \ VAVA V A\ - V` / / \ \ \ \ - / / / 10' OFF SYSTEM, / - ALONG SWALE AND REVEGETATE. - - - v v v v v A \ V A VA \��' A A \ �\V I / \ V A V A \ /� / //,TYPICAL / - v ` VA V - - - . --1 v � w v A 1 A A \VA \\ VAA � \ V A V0 AVA�AA / / / / \ \ - -\ 14 \ \ I \ \ \ \ \ \ \\\ V / / �/ / 24 v v v �/// --- - � vvv - - - y -v v v v 13v v v\ I I \ V�VA VA\\\ \\ vvv v A / 9 \ % / / vvvv v - -v ,, vv \-- v v- v vv v vv vvvvv l - / / / A \ A \V AA V �i / // / / \ - - - v�v vv�o - - - - - v v v � v v v., \A \ V A - - A V�VA \ VA v VAV A \� \VA�\\ / A / \/ // A - - - vv' v z - - - - - - v v v v v v v v v v i \ \ vvv VAA\VA VA\\I . \ /� �' \ \v A V A / j - A�ws��- A�v v � v v v \ v� ,� \ \ \ / / i i i o A / /\// vA AV A / / v vvv Vv ---- - V v A V v v \ \ V // A\ \ \\ \ VAVA AA VA \\ V A\\ / _ / _ / �� / A � �0 A �\ / / / \ V A - AA V�V A - V - - - - - - - \ V A \ �F' V A \ \ ,V , V A \ � - - � � I\\ � V� VAA � \ \ VA V\ V A \\\ \� / / _ /- A \ \ \ / / \ - V A A \ I - AA \ \ - - - A \ V A v� - A \ V A \ - - - - - \ \ \\ \ \ \ \ VA \ �\ v v v v v v v v v - A / / \ \ V A \ \ \ 1. / / �- -A v v�v A - - v Vv A v �� --' i \ \\ \ \\ ,r -_ v � , v v vv - - , v s v �v v s, vv �v v v v�vv�Il / / 55-� -� �� v vv \v v A - v - v v v vv v- Vv - /\/ \ \ V\ \ V A\ \ / 5 f� \ \ \ \ �/ N / �V A A V A A VA � - - / / I \ % \� I \ \ - - - A V A A A h� / \ / / \ / \ FES: 529.50 \ \ \ \ \ \ \ \� \ - - \ \ \ \ \\ \ \ \ \ \ \\ \ - - - - \ \ /� / -- / / / / / I / -- vv ��s v \ v - v�v- v� �v - A - � A v - - ---- -//// / /// I I\TVA\VA\\\VA AIII\I APRON @ FES: / / �/� - v v \ \ \ �v vv v -�v vv v v -- v \ �_ s� v v v vvv ---- / \ \ / / I � I I CLASS 1 RIP RAP: A vv v \ v v v v A o v v vV v - - �­�v - \ - � / \ \ t / / / � / - - - v / / v 1 s'Lx18'wx24"T ` vAv v v - � v v vv v v v v - v � s� v v v v� v � � � v v vim-- - v - - v v v v - - - -sus_ - -� / / / / , , ) / )� )�/II/�h / V / /- - �/ _ �/ �/ / \ v v v v v -v v v v v vv v - - \ - - - _ lii�/ �� v v V� \ v \�v \ v v V A / �� v v v - v v - _ - A - -- - -- i/\/ /\ //A II I / d / / / {�/� / \� �� A A \ \ A VA \ v v �� \ \ A \ \ vA - v v v v - vA - / // / \ 23 / / / \ / / i/ // / \ \ \ \ \ \ \ \ \\ \ \ ` \ - - \ oa - \ - - - - - - �/ / /�/ // / / �i CULVERT 3.0: / bF v A \ \ \ \ V A v A V A ) / \ V A v v S v - v - - - - - - - �Oss-- � _ i / / /// / � 85.8 LF 24" RCP / / A \ V A \ \ V A v - v v v v � / // / ) v \ \ � ( / A \ \ �A A \ \ v V v v v v - sag- - / � �� /�j / / / v V V A I / / C� 1.20% SLOPE \ i / -'-�,, 1-1 - v v v A \ \ \ V A \ \ \ VA V A A \ \ V �� \� - v V v - v v v - - i i� i //� / / -) \ \ I / / i - -� -- - � V A \ \ V / �- A \ V A V A - \ A - \ \ - - - - - - - - - - - - - - - -_ // � \/ \ - \ \ V A I ��(/ \ ) �� I I N V A - - _ - - - - - V \ \ \ \ \ \ \ \ \ \ \, \ \ / A \ -- - - A A \ - - - - - - - _ - - - - - -_ _ - - - �/_ �/ / / / V A \ I I / / / - AA \ - - - - - - - V A \ \ \ \ V A� VA \ \ \ \ \ \ V t� \ \ V / \ A A \ - - - - -A- - - - -\-- - � - - - - - - - - - - - % - /// �� /// �/) v A V A ��\ v v� sF - - \ v v v \ \ v v s� V OPEN SPACE v \ \ \ BUFFER - v =\ - - - -- ; -v - - - - -- - v - _ _ _ _ - - - = , , ; _� �/ �ii� /i / \ \ I 1 / I ( I / - ----- �-_ --2� --- \ \ \ \ \ \ \ \ \ \ \\ ) .L'-' - - -�- --- ;-� \- --------_ ----- ------- --=- --__---- 5 / // //// J - \ \ �' \ \ \ STREAM a, - - - 520-- N5 / CALL BEFORE YOU DIG ... ITS THE LAW. GRAPHIC SCALE ) ) ) \ \ \ 1 \ / / // �/ / 0 / / \ / / % - - z _ \ - -- \ �\-�- - _ _ _ _ _ _ __ �-5'0- � _ - _ _ _ _ - \ \ \ I / / / CALL N.C. ONE -CALL 1-800-632-4949 / / o • _ \ - - -� - - - -- _ _ - - ( ) 60 0 30 60 120 240 / / \ / / / / / / / / I/ // / / ' / / � \ \ \ / - _ \ � - SO$\ - _ _ -\ � � � - - � _ / - - - - - - - i i i FOR LOCATION OF UNDERGROUND UTILITIES AT LEAST / / / / / \ / / / / \ / / �I• • - • ' - ' - _ \ - - _ - - - - - - - - ; - - =� - /_-� - - - - - - - s -,/ �" / / .2,�.. �'. � - - - --- - --i i- � ---� ��� 2 WORKING DAYS PRIOR TO BEGINNING GRADING OR TRENCHING. / \ / / / �/ � // / / / o - - - - -\ - - _ - - - - - - -- 5i-- -- - _ _ _ _ _- - - NORTH CAROLINA GENERAL STATUTE 87-102 / / / \ \/ 17 \ ` / // / �� �w - - - - - - - - - �' - - - _ / / / V / /�// i STREAM \ - - - v - -A %�� - ii - /�--- , --- ( IN FEET ) / � / /// / .I, A v - - - - - - - -- ' - / / � ,/�_� ,-- / /////. A/ // I L•./.� v - -- \ l / �I ---- �� - ,-/"'- -_-_- i 1 inch = 60 ft. - 17-002 Project Name (10/17/2019) Existing Proposed Gross Land Area (GLA): 1,818,140 1,818,140 Project Area: (GLA-surface water) 1,599,584 1,599,584 Impervious Area (site) Roof 992 0 Roadway 0 50,518 Parking/ Driveway 9,212 2,581 Sidewalk 0 180 Impervious Area (lots 1-32) Roof each lot = 2,000 Driveway each lot = 1,000 Sidewalk, patio & hardscape each lot = 500 Lot allowance each lot = 1,000 Impervious per lot each lot = 4,500 Total impervious for all lots 32 lots = 144,000 Impervious Area (lot 33) Driveway 16,491 Future Roadway 20,000 Future Development 60,009 Total Lot 33 Build Out 96,500 Pervious Area Landscaping/ Other Pervious 1,589,380 1,305,805 Surface Water 218,556 218,556 Protected Forest 0 0 Other Areas Custom Land Cover 0 0 Land Taken Up by SCM 0 0 Total All Areas: 1,818,140 1,818,140 Total Impervious Area: 10,204 293,779 Total Impervious % of GLA 0.56% 16.16% Total Impervious % of Project Area 0.64% 18.37% a • U nn n� E I C: gO �� Hflo - .L- Q) U C i N W r"I L- (z U �N���j +--j Q) � N a) O C9 0 U C/)CuLnCO O ,,Y U c,Umm Z � CU U mina_ CU W II N20-U-LU O IIIII!mI I=I O P4 U x O 4 EI P;� 4 O U 4 7 1IIIIII � 0I IIIIIII mm mT0 0 0 0 cIRT c W N LU C# Z z� wv Z Q �_ U U Z_ Oe E .J Ill d O I- C/D P-4 z O z 2 2 z O O O 0 Z v UC E OIL � O cl U) oc00oc LU LU LU L1= LU 0 D_ m LU D_ rn rn rn C) w o 0 0 0 � N N N N .:I0000 (.0 (.0 (.0 0 7 C\j f - LLu r N C0 � DATE: AUGUST 29, 2018 HORIZONTAL SCALE: V=60' VERTICAL SCALE: N/A PROJECT MANAGER: CPK DRAWN BY: CPK PROJECT NO: 17-002 DRAWING NAME: 17-002 REVIEW THIS DRAWING AND THE DESIGN HEREON ARE THE PROPERTY OF EarthCentric Engineering, Inc. THE INFORMATION ON THIS DRAWING IS NOT FOR USE ON ANY OTHER SITE OR PROJECT. THE REPRODUCTION OR OTHER USE OF THIS DRAWING IN WHOLE OR IN PART, WITHOUT WRITTEN CONSENT OF EarthCentric Engineering, Inc., IS PROHIBITED. COPYRIGHT 2019 EarthCentric Engineering, Inc. SHEET NO. �%(�"Wm(�§)� P:\17-002\17-002 Drawings\6. Rev04\17-002 Review.dwg, C5.0 - G&SD Plan, 10/17/2019 11:55:35 AM PRELIMINARY SUBDIVISION PLAN F'AN(-LL IU#J I /U,)Ub, I /U,)UJ, I /U.S I U, I n&1 14, 1 ny I I b, 15y I I / N u 01111111a �C h, wy sg VICINITY MAP i"=2,000' Irmo co aw—QIYo oN TERMINATION POINT OF EXISTING 8" ORANGE-ALAMANCE PUBLIC WATER MAIN (PER ORANGE-ALAMANCE). FIELD VERIFY PRIOR TO START OF CONSTRUCTION. BRANDYWINE DR O,p 3 COORDINATE WITH ELECTRICAL PROVIDER TO RELOCATE POWER POLE PROPOSED 8" WATER MAIN EXTENSION UTILITY PLAN NOTES 1. LOTS TO BE PUBLIC WATER AND INDIVIDUAL SEPTIC SYSTEMS. 2. ALL HOMES TO BE CONSTRUCTED WITH SPRINKLER SYSTEM DUE TO LOW FIRE FLOWS. BORE AND JACK USING 16" ENCASEMENT PIPE 8"X8" TEE 3x8" GATE VALVE \ FIRE HYDRANT ASSEMBLY \ / 6" LEG AND VALVE 8"X6" HYDRANT TEE \ 1? PROPOSED 8" 9'0 / WATER MAIN FIRE HYDRANT ASSEMBLY\ 6" LEG AND VALVE 8"X6" HYDRANT TE \\ <01� 2 CV Q /;v � m 2 / � 2 2� c Co sz /.sz BORE AND JACK USING 16" ENCASEMENT PIPE 8"X8" TEE 3x8" GATE VALVE / 8"X8" TEE 3x8" GATE VALVE I PUBLIC STORM EASEMENT \ / 10' OFF SYSTEM, \ TYPICAL I� / I I I I+ 8" WATER MAIN ti / ? PUBLIC — / STORM EASEMENT, 10' OFF SYSTEM, TYPICAL FIRE HYDRANT ASSEMBLY 6" LEG AND VALVE 8' X6" REDUCER r CALL BEFORE YOU DIG... IT'S THE LAW. GRAPHIC SCALE CALL N.C. ONE-CALL(1-800-632-4949) 80 0 40 80 160 FOR LOCATION OF UNDERGROUND UTILITIES AT LEAST 2 WORKING DAYS PRIOR TO BEGINNING GRADING OR TRENCHING. NORTH CAROLINA GENERAL STATUTE 87-102 ( IN FEET ) 1 inch = 80 ft. 320 LL, ED . 1-� \ \ I., . Ld —__—_ I +�+ w + + + EXTEND MAIN ONE \ �\ — _ —_ _ _/ _ _ I \ v JOINT BEYOND TEE — I — _ L/ / �\� + + + AND VALVE. CAP _ — — > / \ I Q FIRE HYDRANT ASSEMBLY / 6 LEG AND VALVE 8"X6" HYDRANT TEE60 EXTEND MAIN ONE + / / + + JOINT BEYOND TEE FUTURE 8" \ \ / // + / + + AND VALVE. CAP WATER MAIN �� J \?,� \ PRIVATE w \ � STORM EASEMENT \ \ (10' OFF SYSTEM) �_ _ _ _ _ =� STREAM / \ \ •�y/�� — — — _ �e,'�a9 _ BUFFER ` ✓ PRIVATE / / \ M EASEMENT (10'ROFF SYSTEM) / FIRE HYDRANT ASSEMBLY 6" LEG AND VALVE 8"X6" HYDRANT TEE 8" GATE VALVE STREAM BUFFER / o STREAM / �. / • • / / _i � fir.: \•:,•.'._•• ' / I HATCHED AREAS INDICATE SUITABLE SOILS FOR SEPTIC 8" WATER MAIN \ + SO / / + + /e FIRE HYDRANT ASSEMBLY + / 6" LEG AND VALVE 8"6" REDUCER I \ 500'+ • I STREAM \ BUFFER + + + + + + + + + + + + PROJECT INFORMATION: OWNER/DEVELOPER: ROBERT M. BRAME 2863 SOUTH JIM MINOR RD MEBANE, NC 27302 PROPERTIES INCLUDED IN PROJECT: 2679 JIM MINOR ROAD 2689 JIM MINOR ROAD PIN# 9802-59-3969 PIN# 9802-59-3974 PARCEL ID# 170308 PARCEL ID# 170309 TAX ID# 9-13-183 TAX ID# 9-13-184 2.8 ACRES 3.3 ACRES 2863 JIM MINOR ROAD 2817 JIM MINOR ROAD PIN# 9802-59-5721 PIN# 9802-59-4690 PARCEL ID# 170310 PARCEL ID# 159117 TAX ID# 9-13-185 TAX ID# 9-13-5 1.68 ACRES 14.25 ACRES CULBERSON LN S JIM MINOR ROAD PIN# 9802-58-4657 PIN# 9802-58-9583 PARCEL ID# 159114 PARCEL ID# 159116 TAX ID# 9-13-4A TAX ID# 9-13-4 6.01 ACRES 13.71 ACRES TOWNSHIP 9: THOMPSON DEED/PLAT REFERENCES: DB: 2823 PG: 0093 PB: 073 PG: 0293 DB: 3239 PG: 0957 DB: 2487 PG: 215 PB: 073 PG: 0293 SOILS: CnB2, CnC2, CnD2, CnE2 = CULLEN CLAY LOAM = GROUP C RvA = RIVERVIEW LOAM = HYDROLOGIC GROUP B WtB = WYNOTT-ENON COMPLEX = HYDROLOGIC GROUP C FEMA MAP #3710980200 K, EFFECTIVE 11/17/2017 FLOOD HAZARDS PRESENT TOTAL ACREAGE: 41.75 ACRES BY SURVEY TOTAL # PROPOSED LOTS: 33 LOTS AVERAGE LOT SIZE: 0.49 ACRES (NOT INCLUDING LOT #33) TOTAL OPEN SPACE: 532,630 SF OR 12.23 ACRES WINDING CREEK TRAIL: 316.09 LF FOREST CREEK LANE: 1,186.86 LF PRIVATE DRIVE: 1,257.87 LF (IN EASEMENT) U nn ��jj nn� � � � O .� o U W r i Cif U C\j uj Co � N (1Co m:t ) Co U CnCMU-)M O ��Y U �Ub)b) z � N .. CZ c cz i LuJ .. 2p cm2OLLLu IRT Ir(D Lu CCV Lu C* Z Z Q- W U Z Q 0_ - U U Z � J I _ CL In C) C)U C) Z 0Lu 0:1 Z Lu O O O Z U O 01: O 01: U I--- Lu c/) F --- cn oc 0 O oc Lu Lu Lu oc Lu 0 D_ oc Lu D_ rn rn rn � Lu o 0 0 0 F N N CV N Q ao - - CR 0 0 0 0 L>LI r N C0 lzt DATE: AUGUST 29, 2018 HORIZONTAL SCALE: V=80' VERTICAL SCALE: N/A PROJECT MANAGER: CPK DRAWN BY: CPK PROJECT NO: 17-002 DRAWING NAME: 17-002 REVIEW THIS DRAWING AND THE DESIGN HEREON ARE THE PROPERTY OF EarthCentric Engineering, Inc. THE INFORMATION ON THIS DRAWING IS NOT FOR USE ON ANY OTHER SITE OR PROJECT. THE REPRODUCTION OR OTHER USE OF THIS DRAWING IN WHOLE OR IN PART, WITHOUT WRITTEN CONSENT OF EarthCentric Engineering, Inc., IS PROHIBITED. COPYRIGHT 2019 EarthCentric Engineering, Inc. SHEET NO. C C) o 0 ':\17-002\17-002 Drawings\6. Rev04\17-002 Review.dwg, C6.0 - Utility Plan, 10/16/2019 2:18:33 PM PRELIMINARY SUBDIVISION PLAN FAK(_LL IU#J I /U,)Ub, I /U,)UJ, I /U,) I U, I n&1 14, 1 ny I I b, 15y I I / M / v A DISTURBANCE: 233,605SF OR 5.363 AC -PA ro / FES OUT:550.25 / APRON @ FES: CLASS A EC STONE: 6'Lx7.5'Wx12"T - o�� / I Iz- O� — O 7� �O Q��Z A, �QVw �+ Q 8"X8" TEE 1000 .``� 3x8" GATE VALVE M -' ����--`° v - � � M i \ o C� n FES IN: 550.56 ) APRON @ FES:, m — / CLASS A EC STONE: O — 4.5'Lx4.5'Wx12"T + i l — — N \ a .i ' 1 �• / — / / I 4° CALL BEFORE YOU DIG... IT'S THE LAW. CALL N.C. ONE-CALL(1-800-632-4949) FOR LOCATION OF UNDERGROUND UTILITIES AT LEAST 2 WORKING DAYS PRIOR TO BEGINNING GRADING OR TRENCHING. NORTH CAROLINA GENERAL STATUTE 87-102 9+50 570 568 566 564 562 560 558 556 554 O 552 F_ 550 LLJ w 548 546 544 542 540 538 536 534 532 530 9+50 - / Q /- O' �O� w' Gg' r,, lb / QQo Iry - 0 '�• ze O I/' �� FES OUT: 538.20 APRON 0 FES: / CLASS A EC STONE: 6'Lx7.5'Wx12"T �C'— �^�OV °6J �, �, / / °1zQ \ �o� I / / / / --- — / �J J0 C,)/ ob off./ o V A \ V A sA / V'� \ 00 o�� v� FIRE HYDRANT ASSEMBLY v ' _ 73 6" LEG AND VALVE o' �\ 8"X6" HYDRANT TEE \ — JL AS WTI 03 PROPOSED 8" WATER MAIN ?�O v O v \ \ \ \ t��Aw v c, v v v ♦ A \ VA \ �� y Q v s v v V A V �A V A J�o� oQ Q"� i/ / \ 42O2 '''T _- - ---- s (o.�� lb o - — v `v i` v O v �� v v v�, �^ v v / / / / \ v �� �v �Q \-o���a @�� �zl i 50.0' A ��.�o�� lb Al .J I / \ I I\/ 1 V 1 n�nn 1 n�rn 11 inn 11 �r)n 1 ?inn 1 ?ern 1 ��nn HIGH PT. STA: 10+36.58 HIGH PT ELEV: 552.92 PVI STA: 10+60.00 PVI STA: 12+70.00 PVI ELEV: 553.20 K: 9.37 PVI ELEV: K: 7.70 540.60 LVC: 65.59 LVC: 45.80 O n O - C77 m + o CD O N O + O� 4 + Ln m Ln Ln 00 00 N Ln Ln Ln M + Ln + O O N N O �> �> U W 0 II 0 > m �oIn N U W > U m > > + L n Q = 0 Ln LLJ m W Ln CD (n Ln 11— 00 II Lij w Q� �iw Ln J W Ld Ln m o W II W °o J + O 0> �J W 4- Ln Ln 0-) _CD W m + O J LLJ 00 1.00% Ln i U N Ln O o / � 2.00% 60.93 LF \ + Ld 0o 18" CLEAR, MIN. 15" RCP @ 0.50% (CULVERT #1.2) i Lw + II O 0-) + Q N— O cn �6� Og Y 0— ~ m w O O �— 16" STEEL 36" COVER, ENCASEMENT PIPE MIN CAD PIPE m — II 8 � W < 8"x8" TEE )8" GATE ES /� ON �qTF� U J— W 2 \ MECHANICAL JOINT RESTRAINTS & CONCRETE BLOCKING N 0.05% 36" COVER FROM DITCH BOTTOM, MIN. 00 O" Ln" W J W- 0-) O- 8"x8" (3) 8" GATE VALVES TEE + MECHANICAL JOINT RESTRAINTS & �- CONCRETE BLOCKING W 10+00 10+50 11 +00 11 +50 12+00 12+50 13+00 1 _5+50 —570 — 568 — 566 — 564 — 562 — 560 —558 —556 —554 —552 —550 — 548 — 546 — 544 00% — 542 — 540 —538 —536 —534 —532 F-530 13+50 M Ln 00 N N O N O Lr) O CO O 0) 00 rl O — 00 CO 00 O 00 0) 00 N 00 Ln N M N N O O 00 r- � N C7) O Lr) 0 0 0 Lr) Ln It� � � M 4- Ln LC) Ln 0 Ln 0 Ln 0 Ln 0 LC) In Lr) Ln W L� W L� W L� W L� W L� W 1i LLI L� 10+00 10+50 11 +00 11 +50 12+00 12+50 13+00 O_ Ld LLJ a • U nn n� • Q� O 'i Wr1:t L_ (z U CC) uj Co � co a) O co 0 U C/)C\JLnCo O U czUa�a� z � cz i W .. N J oL.111 L.W IRT cc� W N W C# Z Zm WZ Z Q a_ _ U U Z_ � J CL = Iz O tL� O I`Emmw� + C W O O � W l! L W O � JO z z W m W z O O O 0 z U m O m 01: o 0 01: w wwOCw 0 IL m W IL W o 0 0 0 I_ cm cm cmN Q 00 C\O C\O cm 0 o CD LLJ r N Cl) DATE: AUGUST 29, 2018 HORIZONTAL SCALE: 1"=40' VERTICAL SCALE: 1" = 4' PROJECT MANAGER: CPK DRAWN BY: CPK PROJECT NO: 17-002 DRAWING NAME: 17-002 REVIEW THIS DRAWING AND THE DESIGN HEREON ARE THE PROPERTY OF EarthCentric Engineering, Inc. THE INFORMATION ON THIS DRAWING IS NOT FOR USE ON ANY OTHER SITE OR PROJECT. THE REPRODUCTION OR OTHER USE OF THIS DRAWING IN WHOLE OR IN PART, WITHOUT WRITTEN CONSENT OF EarthCentric Engineering, Inc., IS PROHIBITED. COPYRIGHT 2019 EarthCentric Engineering, Inc. GRAPHIC SCALE SHEET NO. 40 0 20 40 80 160 1 00 ( IN FEET) 1 inch = 40 ft. PRELIMINARY SUBDIVISION PLAN P:\17-002\17-002 Drawings\6. Rev04\17-002 Review.dwg, P1.0 - Winding Crk. P&P, 10/16/2019 2:50:00 PM F'AKI LL IU#J I /U,)Ub, I /U,)UJ, I /U.S I U, I n&1 14, 1 ny I I b, 15y I I / o L_ o00 y\ 05 rri y� L \ A F \ s - / / �j 1 �� 545 / / 9ro a Cp00 CD ' A + / � ®♦ _ f \ -moo A 0 - _ - - �----- �Cl,O� n`��°mac I \ I \ \ a pZ \ \ V A \ A F� 0,0 \ \ \ \ V \ vvvv v y v �� - `���v y%�j y-----F�y� // / / / /(�� 51 I / �C' / l �� \cam<N�o�� �� �� � \II l / GRAPHIC I S�AILE / v v \sue o�< 40 / / 0 / 20 / 4� 80 I / I 190 A \ \ \ \ \ (P�G�co F / / / \ ✓ / / / (IN FEET1 )/ / / � � � \ \ \ \ \ \ \�� / 1 inch 0 ft./ / A I V A \� �_ A A.\ \ \, /1 -L7r, 1 n-Lnn \ \ \ \ \ V AQ \ v )sm I mmm- � , c yeti tiT / Fp \ ,�aftra� I - ♦, Lq�F'L/B/ // mho ' I � V�\ \ \ � V A \ /\\ V A - / wo No _ �. _ \ O A A I \ + 16 0+00 41 - \ - _ - o 2 �7 T� oft one 70 aft --J p�c -� - - / / / / - --C�;'o - ---- IAO ID / I vNCo���EO 1O IL A--�- STATION 1 n-L�7'n 1 1_Lnn 1 1_L�7n 1)-Lnn 1 1)_L�7'n 1-�_Lnn 1-�_L�7'n 1 d-Lnn 1 d-L�7,n 197,_Lnn 197,_L�7'n 1 F_Lnn 1 F_L�7'n 17-Lnn 17-L�7n 1Q_Lnn 1Q-L�7n 10_Lnn 10-L�7n I)n-Lnn 1)n_L�7'n a U � .� o 'i W Tt L Cz U �N���j � N a) co U J) C\j L5 M O Uz T T N N .. CZ c cz i Lu .. 2 N21-0-LL.W J �mmwo1 � O L) N 21 +00 21 +50 22 00 22 - LOW PT. STA: 12+33.68 LOW PT ELEV: 538.25 - HIGH PT. HIGH STA: PT ELEV: 17+82.19 551.03 PVI STA. 10+40.61 PVI STA: 11+83.68 PVI STA: 14+94.67 PVI STA: 17+41.57 PVI STA: 20+00.00 PVI STA: 21+36.86 PVI ELEV: 544.78 PVI ELEV: 537.63 PVI ELEV: 540.74 PVI ELEV: 552.43 PVI ELEV: 547.26 PVI ELEV: 540.42 K: 20.00 K: 25.00 K: 40.14 K: 29.69 K: 33.33 K: 32.45 564 LVC: 40.00 LVC: 150.00 LVC: 150.00 LVC: 200.00 LVC: 100.00 LVC: 70.00 564 I 00 00 r� 00 cp 00 r0 00 cp 00 r� r- O rn O-) r- O rn N r- Ln O r- - r- Ln re)O O LIDO N - O co r- c0 00- (0 00 r7 O Ln O� N� C°� ++ Lo Ln 00 O� + � 00 Ln� + 00 Ln O �r� + a7 Ln 0-) cow + -,1- LO �� + Ln �Ln + O Ln O Ln� + 00 Ln O 4 Ln O� + N U) �� + Ln 562 562 Ln� + o+ N Ln O 00 CO 0)...._ O N Ld N N m W 0 m (n U U > W (n U > m (%j U U > W (n U > m z co Q O O m O (n U > W (%j (> U > m U > W C) U > CO 0 U > W jj j j m W ; ; 0+ � LLj r-_ ; W m U ; m ; W W Op W m W m Oj II > > LjJ Q J ,Ln DD 558 J W U) Li W > LO Ln CO � w 556 Li> CD + 17 Ln bi J W O N - 554O 00 O co 554 + Ln552 N > - D_ Ln - 552- W W I j - - - - - -6 MAINTAIN 36" COVER, w w MIN 0 � OF PIPE w-Of o 0 z 550 - - 2.0011 + O N In Q Ln Ln 00 _ 00 p� ro � o+In Li C° 548 _� o+ m `n 000 ro Ln > U) 11 w Ln > i I of Q J N 3, Dog o0 Lin STA: 1 +71.52 �� �% DUCTILE \ w w cn w ELEV: 40.842 IROli-ruN N > w � WATER MAIN Li I w w / \ \ � 544 so + rn MAINTAIN 36" COVER, (0 N + \ 09, , 8"x6" HYDRANT TEE 6" GATE VALVE WATER CONTINUES MIN CAD OF PIPE -N + M LMECHANICAL JOINT RESTRAINTS, TO CUL-DE-SAC U + �j / 53.50 .(CULVERT LF 18" RCP #4.0) C�? 0.56% RODDING SEE HYDRANT & CONCRETE DETAIL. BLOCKING. \ D(7CT' w 1.00% ? 84,% 540- CF �Ro/V CLEAR � � � \ � q - - - - - - -' MIN. 538 \ TFR Mq7� - ----- -- - 536- IRON WATER MAIN g" DI LE CALL BEFORE YOU DIG... IT'S THE LAW. 534- 85.77 LF 24" RCP @ 1.20% (CULVERT #3.0) CALL N.C. ONE-CALL(1-800-632-4949) FOR LOCATION OF UNDERGROUND UTILITIES AT LEAST WATER CONTINUES TO CUL-DE-SAC 532 8%8" TEE (3) 8" GATE VALVES 8"x6" HYDRANT TEE 6" GATE VALVE MECHANICAL JOINT RESTRAINTS, RODDING & CONCRETE BLOCKING. MECHANICAL JOINT RESTRAINTS & 2 WORKING DAYS PRIOR TO BEGINNING GRADING OR TRENCHING. NORTH CAROLINA GENERAL STATUTE 87-102 SEE HYDRANT DETAIL. CONCRETE BLOCKING t /U I UtUU I UtOU I I tUU I I tUU I ZtUU I ZtOU I JtUU I JtIU I'+tUU I'+tOU I UtUU I UtUU IOtUU IOtUU I /tUU I /tUU I OtUU I OtUU I ytUU I ytUU ZUtUU ZUtUU Z I tUU Z I tUU ZZtUU ZLt N O r` 00 0) 0) LO LO 00 rO O 0) 0) r- 0) r` OD O N n r7 L0 00 r` o') Li) N r- r7 (0 0) (0 r7 (0 't 0) 0 (O O (O 0) N rO O N M a0 (D (o c0 lq: c0 N N r-: (0 r It r` r- O n OD 00 OD 0) r- N N N r7 N OD n r- O N 0) L0 (0 lr-� It n LO 0) (O 00 (0 00 (0 00 r` 0) 00 0) 00 O 0) N r"') r` O 06 6 O O O 6 O O 6 06 06 r` (O N N 00 O � It n It rO r) n rO n rO rl) r) r) rM PO PO PO rO 4- n 't 't L0 It Lr) � Lr) Li) L0 Li) � L0 � � r) � 6 6 L0 L0 LO L0 L0 L0 L0 L0 L0 L0 Lr) Ln Ln Ln Ln Ln Ln L0 Lr) L0 L() L0 Lr) L0 L0 Li) L0 Li) Li) L() 0 Li) L0 Li) L0 L0 L0 L0 L0 L0 L0 L() Lr) Lr) Lr) Lr) Li) Ln W L� W ILL W ILL W ILL W ILL W ILL W ILL W ILL W ILL W ILL W ILL W ILL W ILL W ILL W ILL LLJ ILL W ILL W ILL W ILL W ILL W ILL W ILL W ILL W ILL W ILL cc IRT W N LuC# Z Z WZ Z U U Z_ � J CCL z 0 z Lu al Lu O O OU z U 0U IL ovc�O� U F-- Lu cn F --- U) oc 0 O oc Lu Lu Lu oC Lu 0 0_ oc W 0_ rn rn rn � Lu o 0 0 0 F__ N N N N Q ao (0 (0 0 � 0 0 0 0 DATE: AUGUST 29, 2018 HORIZONTAL SCALE: 1"=40' VERTICAL SCALE: N/A PROJECT MANAGER: CPK DRAWN BY: CPK PROJECT NO: 17-002 DRAWING NAME: 17-002 REVIEW THIS DRAWING AND THE DESIGN HEREON ARE THE PROPERTY OF EarthCentric Engineering, Inc. THE INFORMATION ON THIS DRAWING IS NOT FOR USE ON ANY OTHER SITE OR PROJECT. THE REPRODUCTION OR OTHER USE OF THIS DRAWING IN WHOLE OR IN PART, WITHOUT WRITTEN CONSENT OF EarthCentric Engineering, Inc., IS PROHIBITED. COPYRIGHT 2019 EarthCentric Engineering, Inc. SHEET NO. P 2 a 0 10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 14+50 15+00 15+50 16+00 16+50 17+00 17+50 18+00 18+50 19+00 19+50 20+00 20+50 21+00 21+50 22+00 ):\17-002\17-002 Drawings\6. Rev04\17-002 Review.dwg, P2.0 - Forest Crk. P&P, 10/16/2019 2:49:26 PM PRELIMINARY SUBDIVISION PLAN FAK(_LL IU#J I /U,)Ub, I /U,)UJ, I /U.) I U, I n&1 14, 1 ny I I b, 15y I I / I L0 L / \ / _-- C 5097S" ��OF �'gN�7Nc �70/y / / l 12��0, FNCgS� qC� S< pp� � m 1 O qTF cF� 8 '�1Fti �S7 > to Rq R q� /V,' / / V / 1v T p Nc x O \ FFS O #- ` C<4s 40 0 00 S �A�� c'�q 6�g FC 873 !/ N M q h , m o c N 7 3k8 cgTF rB�T TF q ° � /F NFFp04 C F14eAl cF. q�N Mq °` / h� / l OR \ �. �t'Uc AF w Cr 0 Z _ C,, o ? C !/ F N ° F �oF't'CF ®� kso" a2. o �F q� �F CIF (T°tiT Tn� R/p qMq RSFQ 0' -' Cp CT p T �CF �</C / / FI T'Q M 8'' � m 0 E4 n M NS ® Os < � F 7 � ST F FNSj q7N \ � ��C � m �n ch rn Co �i (/�+ 2g�S" qR /F l 0/ A / cn In> r l j 00 c a z �n R �p� ° S� 0 Cp >�� °° �o�o F °F V x ;u � � c� � f'i , A p�A //V. _ � A h i 2 0 R cnn2 <m8 F / \ / / A p u, �cR�r S<� FC �F30 NCO \ \ \ p �A cn — no s. T° s• oR OT \ �SF=�SF� � \ Rp F�i� N O m O i 1>ooJIM MINOR ROAD /Cj� �T - wa� �-�-w S.R. 213 w 1 +ooi — 13+00 �� -��F- 'I (60' PUBLIC R/W) 5+00 18+0 — o i m i i i _ 1 Q , X R �X� XE XE XE% —� XE l �` XE XE —X� O . � �" y°o / -- -- 6- — / ' iS q't'Oi rTy Rq 8 "S �q'1'T PO qO C°NF4 A' / "" FC qs R T�q�gFTFR�r�NC — / \ /yyp�N�� �F�e< y 1 < gcgNo S / i Al I / 0. mo, I r�Tl O h� � o�� '1 I i / \ � Roy � ` _GRA�HtC,SCALE 2,g // / ro 4d 0 20 40 80 160 / / I, IN FEET) \ � � � 1 inch = 40 ft. 9+75 10+00 m 26.0' N � 41 � 't'F q o� " L ' � 550 —SF— 1s+oo F SF SF SF 1s+oo SF SF Sf SF 20+00 S�-Sf z1+0o z �/ --- -- XE XE XE --— ----- — — — — — — — \ / A .. 0, A I — — - — — - — —� i qA S / \ / �sgs5-560 TON Vmoo- 0 os p� -� 0 STATION 1n��7,n 11�nn 11��7,n 1,)inn 1)��7,n 1��nn 1���7,n 1a�nn 1a��7,n 1��nn 1���7,n 1F�nn 1F��7,n 17�nn 17��;n 1R�nn 1R��7,n 1a�nn 1a��7,n ?n�nn ?n��;n 1�nn ?l�gn 22 00 578 CALL BEFORE YOU DIG... IT'S THE LAW. 578 CALL N.C. ONE-CALL(1-800-632-4949) 576 FOR LOCATION OF UNDERGROUND UTILITIES AT LEAST 2 WORKING DAYS PRIOR TO BEGINNING GRADING OR TRENCHING. NORTH CAROLINA GENERAL STATUTE 87-102 572 \ \ \ MAINTAIN 36" COVER, MIN @ OF PIPE 568 _ 566 564 2 560 CONTRACTOR TO LOCATE AND — 558 CONNECT TO EXISTING 8" WATER MAIN PIPE IN SHOULDER MAINTAIN 36" COVER, MIN 0 OF PIPE 556 554 2 — \ — _ — 552 n - 8"x8" TEE (3) 8" GATE VALVES MECHANICAL JOINT RESTRAINTS & CONCRETE BLOCKING 36" COVER FROM DITCH BOTTOM, MIN. 548 546 44 542 8"x8" TEE (3) 8" GATE VALVES MECHANICAL JOINT RESTRAINTS & CONCRETE BLOCKING 36" COVER FROM DITCH BOTTOM, MIN. I I I 9+75 10+00 I UrtJU I I rtUU I I rtJU I LrtUU I LrtJU I JrtUU I JrtJU I `FrtUU I `FrtJU I JrtUU I JrtJU I OrtUU I OrtJU I /rtUU I /rtJU I OrtUU I OrtJU I yrtUU I yrtJU LUrtUU LUrtJU L I rtUU L I rtJU 22+00 LO D_ - D_ LO - D- LO D- LO D- LO D- � - D- � - D- 0 D- In L 0 - D- D- N N D- Cb D- r7 D- a_ 0 D- � D- � D- 0 D- 0 0 D- In D- D- ON r-s F- O� F-� r2 O� F-N r7 00 0CC) r7 0n APO r7 O0) �a0 po OIt �� po O� APO r7 0n �N M 00 �� r7 ON �N O� r7 r7 0� �� r7 0� �O r7 0m �00 0� CO r7 0(0 N r7 0(0 (» r7 00 r- r7 ON C0 O� r7 � on � r7 0( N � Dr- I� W > U W W 04 W W W Of W 0) W D_ W 00 W 0_ W CO W LO Of W L0 W W � W of W P7 W D_ W N W n of W W L0 W > O WLr) D_ W m W of W OD W D_ W W I W > U rl W of W rl W D_ W W D_ W CO W 0-1 W Cp W W > CO of W� W Cp W of W Cp W W > W U 0_ L0 > OLn 0D > O 0L > O D > O D > O D > D > D > O D > O L > O DLr) D > D > D > DL) > O D DL) > D > O) D ) D > O_Ln D L�EC) U i U U U O O L FL F O U 0 U F 0 U U O U U U FL U C�9 • n �j n� O 'i W rqt L_ U CC) uj a) � a)OCOO U � C\J U-) 7 O N U U Z � CZ cz i W .. 2 J N2a-LL.W cc Ls) W N W C# Z z wv Z a__ U U Z_ Oe Er .J a= a ® C� O � x Cl) o O L) W .. W W W J z O z z O OU O 0U z U 01:�O01: U F-- w cn F --- U) oc 0 O oc w wwoCw 0 D_ oc W D_ rn rn rn � Lu o 0 0 0 N N N CD Q 00 C\O CCR CD CD CD CD LI J r N Cl) DATE: AUGUST 29, 2018 HORIZONTAL SCALE: 1"=40' VERTICAL SCALE: 1" = 4' PROJECT MANAGER: CPK DRAWN BY: CPK PROJECT NO: 17-002 DRAWING NAME: 17-002 REVIEW THIS DRAWING AND THE DESIGN HEREON ARE THE PROPERTY OF EarthCentric Engineering, Inc. THE INFORMATION ON THIS DRAWING IS NOT FOR USE ON ANY OTHER SITE OR PROJECT. THE REPRODUCTION OR OTHER USE OF THIS DRAWING IN WHOLE OR IN PART, WITHOUT WRITTEN CONSENT OF EarthCentric Engineering, Inc., IS PROHIBITED. COPYRIGHT 2019 EarthCentric Engineering, Inc. SHEET NO. p QO) a 0 P:\17-002\17-002 Drawings\6. Rev04\17-002 Review.dwg, P3.0 - Offsite Water P&P, 10/16/2019 2:48:56 PM PRELIMINARY SUBDIVISION PLAN FANULL lu#J I /UJU0, I /UJU'J, I /U,S I U, 1 5y I 1 4, 15y1 1 b, 1 5y11 / GROUND STABILIZATION AND MATERIALS HANDLING PRACTICES FOR COMPLIANCE WITH THE NCGO1 CONSTRUCTION GENERAL PERMIT Implementing the details and specifications on this plan sheet will result in the construction activity being considered compliant with the Ground Stabilization and Materials Handling sections of the NCGO1 Construction General Permit (Sections E and F, respectively). The permittee shall comply with the Erosion and Sediment Control plan approved by the delegated authority having jurisdiction. All details and specifications shown on this sheet may not apply depending on site conditions and the delegated authority having jurisdiction. SECTION E: GROUND STABILIZATION Required Ground Stabilization Timeframes Stabilize within this Site Area Description many calendar Timeframe variations days after ceasing land disturbance (a) Perimeter dikes, swales, ditches, and 7 None perimeter slopes (b) High Quality Water 7 None (HQW) Zones (c) Slopes steeper than If slopes are 10' or less in length and are 3:1 7 not steeper than 2:1, 14 days are allowed -7 days for slopes greater than 50' in length and with slopes steeper than 4:1 -7 days for perimeter dikes, swales, (d) Slopes 3:1 to 4:1 14 ditches, perimeter slopes and HQW Zones -10 days for Falls Lake Watershed -7 days for perimeter dikes, swales, (e) Areas with slopes ditches, perimeter slopes and HQW Zones flatter than 4:1 14 -10 days for Falls Lake Watershed unless there is zero slope Note: After the permanent cessation of construction activities, any areas with temporary ground stabilization shall be converted to permanent ground stabilization as soon as practicable but in no case longer than 90 calendar days after the last land disturbing activity. Temporary ground stabilization shall be maintained in a manner to render the surface stable against accelerated erosion until permanent ground stabilization is achieved. GROUND STABILIZATION SPECIFICATION Stabilize the ground sufficiently so that rain will not dislodge the soil. Use one of the techniques in the table below: Temporary Stabilization • Temporary grass seed covered with straw or other mulches and tackifiers • Hydroseeding • Rolled erosion control products with or without temporary grass seed • Appropriately applied straw or other mulch • Plastic Sheeting Permanent Stabilization • Permanent grass seed covered with straw or other mulches and tackifiers • Geotextile fabrics such as permanent soil reinforcement matting • Hydroseeding • Shrubs or other permanent plantings covered with mulch • Uniform and evenly distributed ground cover sufficient to restrain erosion • Structural methods such as concrete, asphalt or retaining walls • Rolled erosion control products with grass seed POLYACRYLAMIDES (PAMS) AND FLOCCULANTS 1. Select flocculants that are appropriate for the soils being exposed during construction, selecting from the NC DWR List of Approved PAMS/Flocculants. 2. Apply flocculants at or before the inlets to Erosion and Sediment Control Measures. 3. Apply flocculants at the concentrations specified in the NC DWR List of Approved PAMS/Flocculants and in accordance with the manufacturer's instructions. 4. Provide ponding area for containment of treated Stormwater before discharging offsite. 5. Store flocculants in leak -proof containers that are kept under storm -resistant cover or surrounded by secondary containment structures. EQUIPMENT AND VEHICLE MAINTENANCE 1. Maintain vehicles and equipment to prevent discharge of fluids. 2. Provide drip pans under any stored equipment. 3. Identify leaks and repair as soon as feasible, or remove leaking equipment from the project. 4. Collect all spent fluids, store in separate containers and properly dispose as hazardous waste (recycle when possible). 5. Remove leaking vehicles and construction equipment from service until the problem has been corrected. 6. Bring used fuels, lubricants, coolants, hydraulic fluids and other petroleum products to a recycling or disposal center that handles these materials. LITTER, BUILDING MATERIAL AND LAND CLEARING WASTE 1. Never bury or burn waste. Place litter and debris in approved waste containers. 2. Provide a sufficient number and size of waste containers (e.g dumpster, trash receptacle) on site to contain construction and domestic wastes. 3. Locate waste containers at least 50 feet away from storm drain inlets and surface waters unless no other alternatives are reasonably available. 4. Locate waste containers on areas that do not receive substantial amounts of runoff from upland areas and does not drain directly to a storm drain, stream or wetland. 5. Cover waste containers at the end of each workday and before storm events or provide secondary containment. Repair or replace damaged waste containers. 6. Anchor all lightweight items in waste containers during times of high winds. 7. Empty waste containers as needed to prevent overflow. Clean up immediately if containers overflow. 8. Dispose waste off -site at an approved disposal facility. 9. On business days, clean up and dispose of waste in designated waste containers. PAINT AND OTHER LIQUID WASTE 1. Do not dump paint and other liquid waste into storm drains, streams or wetlands. 2. Locate paint washouts at least 50 feet away from storm drain inlets and surface waters unless no other alternatives are reasonably available. 3. Contain liquid wastes in a controlled area. 4. Containment must be labeled, sized and placed appropriately for the needs of site. 5. Prevent the discharge of soaps, solvents, detergents and other liquid wastes from construction sites. PORTABLE TOILETS 1. Install portable toilets on level ground, at least 50 feet away from storm drains, streams or wetlands unless there is no alternative reasonably available. If 50 foot offset is not attainable, provide relocation of portable toilet behind silt fence or place on a gravel pad and surround with sand bags. 2. Provide staking or anchoring of portable toilets during periods of high winds or in high foot traffic areas. 3. Monitor portable toilets for leaking and properly dispose of any leaked material. Utilize a licensed sanitary waste hauler to remove leaking portable toilets and replace with properly operating unit. EARTHEN STOCKPILE MANAGEMENT 1. Show stockpile locations on plans. Locate earthen -material stockpile areas at least 50 feet away from storm drain inlets, sediment basins, perimeter sediment controls and surface waters unless it can be shown no other alternatives are reasonably available. 2. Protect stockpile with silt fence installed along toe of slope with a minimum offset of five feet from the toe of stockpile. 3. Provide stable stone access point when feasible. 4. Stabilize stockpile within the timeframes provided on this sheet and in accordance with the approved plan and any additional requirements. Soil stabilization is defined as vegetative, physical or chemical coverage techniques that will restrain accelerated erosion on disturbed soils for temporary or permanent control needs. ONSITE CONCRETE WASHOUT STRUCTURE WITH LINER SANDBAGS (TYP.) OR STAPLES 10 MIL SILT FENCE SIDE SLOP LINING C SANDBAGS (TYP.) (TYP. OR STAPLES O X J< HIGH � COHESIVE Sc LOW FILTRATION SOIL BERM CLEARLY MARKED SIGNAGE SECTION A -A CONCRETE NOTING DEVICE (18"X24" MIN.) NOTES: WASHOUT 1. ACTUAL LOCATION DETERMINED IN FIELD 2. THE CONCRETE WASHOUT STRUCTURES SHALL BE MAINTAINED WHEN THE LIQUID AND/OR SOLID REACHES 75% OF THE STRUCTURES CAPACITY. PLAN 3.CONCRETE WASHOUT STRUCTURE NEEDS TO BE CLEARY MARKED WITH SIGNAGE NOTING DEVICE. BELOW GRADE WASHOUT STRUCTURE NOT TO SCALE 10' MIN SANDBAGS (TYP.) B OR STAPLES 10 MIL HIGH O 0 PLASTIC LINING LOHESIVE FILTRATION 0 �1TYP) E SLOP SOIL BERM o SECTION B-B SANDBAGS (TYP.) OR STAPLES NOTES: 1. ACTUAL LOCATION DETERMINED IN FIELD CLEARLY MARKED SIGNAGE CONCRETE NOTING DEVICE (18"X24" MIN.) 2. THE CONCRETE WASHOUT WASHOUT STRUCTURES SHALL BE MAINTAINED WHEN THE LIQUID AND/OR SOLID REACHES 75% OF THE STRUCTURES CAPACITY TO PROVIDE ADEQUATE HOLDING CAPACITY WITH A MINIMUM 12 PLAN INCHES OF FREEBOARD. 3.CONCRETE WASHOUT STRUCTURE NEEDS TO BE CLEARY MARKED WITH SIGNAGE NOTING DEVICE. ABOVE GRADE WASHOUT STRUCTURE NOT TO SCALE CONCRETE WASHOUTS 1. Do not discharge concrete or cement slurry from the site. 2. Dispose of, or recycle settled, hardened concrete residue in accordance with local and state solid waste regulations and at an approved facility. 3. Manage washout from mortar mixers in accordance with the above item and in addition place the mixer and associated materials on impervious barrier and within lot perimeter silt fence. 4. Install temporary concrete washouts per local requirements, where applicable. If an alternate method or product is to be used, contact your approval authority for review and approval. If local standard details are not available, use one of the two types of temporary concrete washouts provided on this detail. 5. Do not use concrete washouts for dewatering or storing defective curb or sidewalk sections. Stormwater accumulated within the washout may not be pumped into or discharged to the storm drain system or receiving surface waters. Liquid waste must be pumped out and removed from project. 6. Locate washouts at least 50 feet from storm drain inlets and surface waters unless it can be shown that no other alternatives are reasonably available. At a minimum, install protection of storm drain inlet(s) closest to the washout which could receive spills or overflow. 7. Locate washouts in an easily accessible area, on level ground and install a stone entrance pad in front of the washout. Additional controls may be required by the approving authority. 8. Install at least one sign directing concrete trucks to the washout within the project limits. Post signage on the washout itself to identify this location. 9. Remove leavings from the washout when at approximately 75% capacity to limit overflow events. Replace the tarp, sand bags or other temporary structural components when no longer functional. When utilizing alternative or proprietary products, follow manufacturer's instructions. 10. At the completion of the concrete work, remove remaining leavings and dispose of in an approved disposal facility. Fill pit, if applicable, and stabilize any disturbance caused by removal of washout. HERBICIDES, PESTICIDES AND RODENTICIDES 1. Store and apply herbicides, pesticides and rodenticides in accordance with label restrictions. 2. Store herbicides, pesticides and rodenticides in their original containers with the label, which lists directions for use, ingredients and first aid steps in case of accidental poisoning. 3. Do not store herbicides, pesticides and rodenticides in areas where flooding is possible or where they may spill or leak into wells, stormwater drains, ground water or surface water. If a spill occurs, clean area immediately. 4. Do not stockpile these materials onsite. HAZARDOUS AND TOXIC WASTE 1. Create designated hazardous waste collection areas on -site. 2. Place hazardous waste containers under cover or in secondary containment. 3. Do not store hazardous chemicals, drums or bagged materials directly on the ground. NCGO1 GROUND STABILIZATION AND MATERIALS HANDLING EFFECTIVE: 04/01/19 .4 0 U U W T � N a) M U �OCflO � (u LO M O UMMY CO CZ Z T T N U a���e 4) U CZ CZ CC U x G O N CZ N2aLLW 101:� W N W� z �W z0- W U Z J i ¢_ IL U U Z_° E J CCL N � Q x o E-+ C/D C/D w 0 mIUUUU � J � w °w z 0 O 0 Z U 0 01:�001: U F-- W cn � co oc 0 0 oc 0 IL 01: LU IL w o000 QN N N C\j o ,--- OD(0(0(0 7 N 7 r­ r­o poor LLJ r N co -,I- DATE: AUGUST 29, 2018 HORIZONTAL SCALE: N/A VERTICAL SCALE: N/A PROJECT MANAGER: CPK DRAWN BY: SCS PROJECT NO: 17-002 DRAWING NAME: 17-002 DETAILS THIS DRAWING AND THE DESIGN HEREON ARE THE PROPERTY OF EarthCentric Engineering, Inc. THE INFORMATION ON THIS DRAWING IS NOT FOR USE ON ANY OTHER SITE OR PROJECT. THE REPRODUCTION OR OTHER USE OF THIS DRAWING IN WHOLE OR IN PART, WITHOUT WRITTEN CONSENT OF EarthCentric Engineering, Inc., IS PROHIBITED. COPYRIGHT 2019 EarthCentric Engineering, Inc. SHEET NO. rlx)� W,(� §)� P:\17-002\17-002 Drawings\6. Rev04\17-002 Details.dwg, D1.0 NCGO1 Details, 10/16/2019 2:23:51 PM PRELIMINARY SUBDIVISION PLAN FANULL IU#J I /UJU0, I /UJU'J, I /U,S I U, 1 5y I 1 4, 15y1 1 b, 1 5y11 / PART III SELF -INSPECTION, RECORDKEEPING AND REPORTING SECTION A: SELF -INSPECTION Self -inspections are required during normal business hours in accordance with the table below. When adverse weather or site conditions would cause the safety of the inspection personnel to be in jeopardy, the inspection may be delayed until the next business day on which it is safe to perform the inspection. In addition, when a storm event of equal to or greater than 1.0 inch occurs outside of normal business hours, the self -inspection shall be performed upon the commencement of the next business day. Anytime when inspections were delayed shall be noted in the Inspection Record. Frequency Inspect (during normal Inspection records must include: business hours) (1) Rain gauge Daily Daily rainfall amounts. maintained in If no daily rain gauge observations are made during weekend or good working holiday periods, and no individual -day rainfall information is order available, record the cumulative rain measurement for those un- attended days (and this will determine if a site inspection is needed). Days on which no rainfall occurred shall be recorded as "zero." The permittee may use another rain -monitoring device approved by the Division. (2) E&SC At least once per 1. Identification of the measures inspected, Measures 7 calendar days 2. Date and time of the inspection, and within 24 3. Name of the person performing the inspection, hours of a rain 4. Indication of whether the measures were operating event > 1.0 inch in properly, 24 hours 5. Description of maintenance needs for the measure, 6. Description, evidence, and date of corrective actions taken. (3) Stormwater At least once per 1. Identification of the discharge outfalls inspected, discharge 7 calendar days 2. Date and time of the inspection, outfalls (SDOs) and within 24 3. Name of the person performing the inspection, hours of a rain 4. Evidence of indicators of stormwater pollution such as oil event > 1.0 inch in sheen, floating or suspended solids or discoloration, 24 hours 5. Indication of visible sediment leaving the site, 6. Description, evidence, and date of corrective actions taken. (4) Perimeter of At least once per If visible sedimentation is found outside site limits, then a record site 7 calendar days of the following shall be made: and within 24 1. Actions taken to clean up or stabilize the sediment that has left hours of a rain the site limits, event > 1.0 inch in 2. Description, evidence, and date of corrective actions taken, and 24 hours 3. An explanation as to the actions taken to control future releases. (5) Streams or At least once per If the stream or wetland has increased visible sedimentation or a wetlands onsite 7 calendar days stream has visible increased turbidity from the construction or offsite and within 24 activity, then a record of the following shall be made: (where hours of a rain 1. Description, evidence and date of corrective actions taken, and accessible) event > 1.0 inch in 2. Records of the required reports to the appropriate Division 24 hours Regional Office per Part III, Section C, Item (2)(a) of this permit of this permit. (6) Ground After each phase 1. The phase of grading (installation of perimeter E&SC stabilization of grading measures, clearing and grubbing, installation of storm measures drainage facilities, completion of all land -disturbing activity, construction or redevelopment, permanent ground cover). 2. Documentation that the required ground stabilization measures have been provided within the required timeframe or an assurance that they will be provided as soon as possible. NOTE: The rain inspection resets the required 7 calendar day inspection requirement. PART III SELF -INSPECTION, RECORDKEEPING AND REPORTING SECTION 6: RECORDKEEPING 1. E&SC Plan Documentation The approved E&SC plan as well as any approved deviation shall be kept on the site. The approved E&SC plan must be kept up-to-date throughout the coverage under this permit. The following items pertaining to the E&SC plan shall be documented in the manner described: Item to Document Documentation Requirements (a) Each E&SC Measure has been installed Initial and date each E&SC Measure on a copy and does not significantly deviate from the of the approved E&SC Plan or complete, date locations, dimensions and relative elevations and sign an inspection report that lists each shown on the approved E&SC Plan. E&SC Measure shown on the approved E&SC Plan. This documentation is required upon the initial installation of the E&SC Measures or if the E&SC Measures are modified after initial installation. (b) A phase of grading has been completed. Initial and date a copy of the approved E&SC Plan or complete, date and sign an inspection report to indicate completion of the construction phase. (c) Ground cover is located and installed Initial and date a copy of the approved E&SC in accordance with the approved E&SC Plan or complete, date and sign an inspection Plan. report to indicate compliance with approved ground cover specifications. (d) The maintenance and repair Complete, date and sign an inspection report. requirements for all E&SC Measures have been performed. (e) Corrective actions have been taken Initial and date a copy of the approved E&SC to E&SC Measures. Plan or complete, date and sign an inspection report to indicate the completion of the corrective action. 2. Additional Documentation In addition to the E&SC Plan documents above, the following items shall be kept on the site and available for agency inspectors at all times during normal business hours, unless the Division provides a site -specific exemption based on unique site conditions that make this requirement not practical: (a) This general permit as well as the certificate of coverage, after it is received. (b) Records of inspections made during the previous 30 days. The permittee shall record the required observations on the Inspection Record Form provided by the Division or a similar inspection form that includes all the required elements. Use of electronically -available records in lieu of the required paper copies will be allowed if shown to provide equal access and utility as the hard -copy records. (c) All data used to complete the Notice of Intent and older inspection records shall be maintained for a period of three years after project completion and made available upon request. [40 CFR 122.41] PART III SELF -INSPECTION, RECORDKEEPING AND REPORTING SECTION C: REPORTING 1. Occurrences that must be reported Permittees shall report the following occurrences: (a) Visible sediment deposition in a stream or wetland. (b) Oil spills if: • They are 25 gallons or more, • They are less than 25 gallons but cannot be cleaned up within 24 hours, • They cause sheen on surface waters (regardless of volume), or • They are within 100 feet of surface waters (regardless of volume). (a) Releases of hazardous substances in excess of reportable quantities under Section 311 of the Clean Water Act (Ref: 40 CFR 110.3 and 40 CFR 117.3) or Section 102 of CERCLA (Ref: 40 CFR 302.4) or G.S. 143-215.85. (b) Anticipated bypasses and unanticipated bypasses. (c) Noncompliance with the conditions of this permit that may endanger health or the environment. 2. Reporting Timeframes and Other Requirements After a permittee becomes aware of an occurrence that must be reported, he shall contact the appropriate Division regional office within the timeframes and in accordance with the other requirements listed below. Occurrences outside normal business hours may also be reported to the Division's Emergency Response personnel at (800) 662-7956, (800) 858-0368 or (919) 733-3300. Occurrence Reporting Timeframes (After Discovery) and Other Requirements (a) Visible sediment • Within 24 hours, an oral or electronic notification. deposition in a . Within 7 calendar days, a report that contains a description of the stream or wetland sediment and actions taken to address the cause of the deposition. Division staff may waive the requirement for a written report on a case -by -case basis. • If the stream is named on the NC 303(d) list as impaired for sediment - related causes, the permittee may be required to perform additional monitoring, inspections or apply more stringent practices if staff determine that additional requirements are needed to assure compliance with the federal or state impaired -waters conditions. (b) Oil spills and • Within 24 hours, an oral or electronic notification. The notification release of shall include information about the date, time, nature, volume and hazardous location of the spill or release. substances per Item 1(b)-(c) above (c) Anticipated • A report at least ten days before the date of the bypass, if possible. bypasses [40 CFR The report shall include an evaluation of the anticipated quality and 122.41(m)(3)] effect of the bypass. (d) Unanticipated • Within 24 hours, an oral or electronic notification. bypasses [40 CFR e Within 7 calendar days, a report that includes an evaluation of the 122.41(m)(3)] quality and effect of the bypass. (e) Noncompliance • Within 24 hours, an oral or electronic notification. with the conditions • Within 7 calendar days, a report that contains a description of the of this permit that noncompliance, and its causes; the period of noncompliance, may endanger including exact dates and times, and if the noncompliance has not health or the been corrected, the anticipated time noncompliance is expected to environment[40 continue; and steps taken or planned to reduce, eliminate, and CFR 122.41(I)(7)] prevent reoccurrence of the noncompliance. [40 CFR 122.41(I)(6). • Division staff may waive the requirement for a written report on a case -by -case basis. NCGO I SELF -INSPECTION, RECORDKEEPING AND REPORTING EFFECTIVE: 04/01/19 nnnn nn� U � o .� o U 'i 0 W L T 1:t� U a)N���j a)OCO t Cfl U UaaY U 00 co Z T T co U � CZ V CZ c O X O N CZ W c�i J c\Ofu_w 101:� W N W� zW z0- W U Z J i Q = IL U U Z_ E J CCL � C DO W x W� � � W w �+ W L) W F� mIUUUU I- J I- z 0 z 2 � 2 z 0 O 00 z U 0U ovc � 0 ovc U W cn cn oc o 0 oc W W W oc W o IL oc W IL LU QN N N N 0 0 o r W r N co � DATE: AUGUST 29, 2018 HORIZONTAL SCALE: N/A VERTICAL SCALE: N/A PROJECT MANAGER: CPK DRAWN BY: SCS PROJECT NO: 17-002 DRAWING NAME: 17-002 DETAILS THIS DRAWING AND THE DESIGN HEREON ARE THE PROPERTY OF EarthCentric Engineering, Inc. THE INFORMATION ON THIS DRAWING IS NOT FOR USE ON ANY OTHER SITE OR PROJECT. THE REPRODUCTION OR OTHER USE OF THIS DRAWING IN WHOLE OR IN PART, WITHOUT WRITTEN CONSENT OF EarthCentric Engineering, Inc., IS PROHIBITED. COPYRIGHT 2019 EarthCentric Engineering, Inc. SHEET NO. P:\17-002\17-002 Drawings\6. Rev04\17-002 Details.dwg, D1.1 NCGO1 Details, 10/16/2019 2:23:52 PM PRELIMINARY SUBDIVISION PLAN F-AKI;tL IU#J I /UJU0, I /UJU'J, I /U,S I U, 1 5y I 1 4, 15y1 1 b, 1 5y11 / COIR FIBER WATTLE \V MATTI 2' ( MAX . ) COIR FIBER WATTLE DETAIL P Pv% e Inset A BACK \ SLOPE ISOMETRIC VIEW 2' UPSLOPE STAKE NOTES: USE MINIMUM 12 IN. DIAMETER COIR FIBER (COCONUT FIBER) WATTLE. USE 2 FT. WOODEN STAKES WITH A 2 IN. BY 2 IN. NOMINAL CROSS SECTION. ONLY INSTALL WATTLE(S) TO A HEIGHT IN DITCH SO FLOW WILL NOT WASH AROUND WATTLE AND SCOUR DITCH SLOPES AND AS DIRECTED. EDGE OF PAVEMENT INSTALL A MINIMUM OF 2 UPSLOPE STAKES AND 4 DOWNSLOPE STAKES AT AN ANGLE TO WEDGE WATTLE TO BOTTOM OF DITCH. PROVIDE STAPLES MADE OF 0.125 IN. DIAMETER STEEL WIRE FORMED INTO A U SHAPE NOT LESS THAN 12" IN LENGTH. INSTALL STAPLES APPROXIMATELY EVERY 1 LINEAR FOOT ON BOTH SIDES OF WATTLE AND AT EACH END TO SECURE IT TO THE SOIL. INSTALL MATTING IN ACCORDANCE WITH SECTION 1631 OF THE STANDARD SPECIFICATIONS. MATTING 7��`�V2' DOWNSLOPE STAKE CROSS SECTION VEE DITCH 2 IN. TURAL GROUND 2' UPSLOPE FLOW -- STAKE NATURAL GROUND �1/�2 2> 22 ,• � � MATTING - 2' DOWNSLOPE CROSS SECTION STAKE TRAPEZOIDAL DITCH CONSTRUCTION SPECIFICATIONS: 1. REMOVE AND PROPERLY DISPOSE OF ALL TREES, BRUSH, STUMPS, AND OTHER OBJECTIONABLE MATERIAL. 2. ENSURE THAT THE MINIMUM CONSTRUCTED CROSS SECTION MEETS ALL DESIGN REQUIREMENTS. 3. ENSURE THAT THE TOP OF THE DIKE IS NOT LOWER AT ANY POINT THAN THE DESIGN ELEVATION PLUS THE SPECIFIED SETTLEMENTS. 4. PROVIDE SUFFICIENT ROOM AROUND DIVERSIONS TO PERMIT MACHINE RE -GRADING AND CLEANOUT. 5. VEGETATE THE RIDGE IMMEDIATELY AFTER CONSTRUCTION, UNLESS IT WILL REMAIN IN PLACE LESS THAN 30 WORKING DAYS. INSPECT TEMPORARY DIVERSIONS ONCE A WEEK AND AFTER EVERY RAINFALL. MAINTENANCE: IMMEDIATELY REMOVE SEDIMENT FROM THE FLOW AREA AND REPAIR THE DIVERSION RIDGE. CAREFULLY CHECK OUTLETS AND MAKE TIMELY REPAIRS AS NEEDED. WHEN THE AREA PROTECTED IS PERMANENTLY STABILIZED, REMOVE THE RIDGE AND THE CHANNEL TO BLEND WITH THE NATURAL GROUND LEVEL AND APPROPRIATELY STABILIZE IT. 2' MIN. COMPACTED SOIL 18" MIN 11-111-111-1 6' TYPICAL TEMPORARY DIVERSION DITCH NTS INSET A INSET B TOP VIEW 12' MINIMUM CONSTRUCTION ENTRANCE/EXIT CONSTRUCTION SPECIFICATIONS: 1.) CLEAR THE ENTRANCE AND EXIT AREA OF ALL VEGETATION, ROOTS, AND OTHER OBJECTIONABLE MATERIAL AND PROPERLY GRADE IT. 2.) PLACE THE GRAVEL TO THE SPECIFIC GRADE AND DIMENSIONS SHOWN ON THE PLANS, AND SMOOTH IT. 3.) PROVIDE DRAINAGE TO CARRY WATER TO A SEDIMENT TRAP OR OTHER SUITABLE OUTLET. 4.) USE GEOTEXTILE FABRICS BECAUSE THEY IMPROVE THE STABILITY OF THE FOUNDATION IN LOCATIONS SUBJECT TO SEEPAGE OR HIGH WATER TABLE. „r_m11a0r_nEy21 MAINTAIN THE GRAVEL PAD IN A CONDITION TO PREVENT MUD OR SEDIMENT FROM LEAVING THE CONSTRUCTION SITE. THIS MAY REQUIRE PERIODIC TOPDRESSING WITH 2-INCH STONE. AFTER EACH RAINFALL, INSPECT ANY STRUCTURE USED TO TRAP SEDIMENT AND CLEAN IT OUT AS NECESSARY. IMMEDIATELY REMOVE ALL OBJECTIONABLE MATERIALS SPILLED, WASHED, OR TRACKED ONTO PUBLIC ROADWAYS. 8' MAX. STANDARD STRENGTH FABRIC WITH WIRE FENCE 6' MAX. EXTRA STRENGTH FABRIC WITHOUT WIRE FENCE STEEL POST 18- 24"- WIRE FENCE{ 24"' STEEL POST NATURAL GROUND 24" 8" DOWN & 4" FORWARD ALONG THE TRENCH WIRE FENCE FILTER FABRIC BACKFILL TRENCH AND COMPACT THOROUGHLY UPS ., 8" MIN. --� 4" MIN. PLASTIC OR WIRE TIES NATURAL GROUND FILTER FABRIC NATURAL GROUND CONSTRUCTION SPECIFICATIONS: U MATERIALS 1. USE A SYNTHETIC FILTER FABRIC OF AT LEAST 95% BY WEIGHT OF POLYOLEFIN OR POLYESTER, WHICH IS CERTIFIED BY THE MANUFACTURER OR SUPPLIER AS CONFIRMING TO THE REQUIREMENTS IN ASTM D 6461, WHICH IS SHOWN IN PART IN TABLE 6.62B OF THE EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL PUBLISHED BY NC DEQ_ SYNTHETIC FILTER FABRIC SHOULD CONTAIN ULTRA VIOLET RAY INHIBITORS AND STABILIZERS TO PROVIDE A MINIMUM OF 6 MONTHS OR EXPECTED USABLE CONSTRUCTION LIFE AT A TEMPERATURE RANGE OF 0 TO 120° F. 2. ENSURE THAT POSTS FOR SEDIMENT FENCES ARE 1.25 LB/LINEAR FT MINIMUM STEEL WITH A MINIMUM LENGTH OF 5'. MAKE SURE THAT STEEL POSTS HAVE PROJECTIONS TO FACILITATE FASTENING THE FABRIC. 3. FOR REINFORCEMENT OF STANDARD STRENGTH FILTER FABRIC, USE WIRE FENCE WITH A MINIMUM 14 GAUGE AND A MAXIMUM MESH SPACING OR 6 INCHES. CONSTRUCTION 1. CONSTRUCT THE SEDIMENT BARRIER OF STANDARD STRENGTH OR EXTRA STRENGTH SYNTHETIC FILTER FABRICS. 2. ENSURE THAT THE HEIGHT OF THE SEDIMENT FENCE DOES NOT EXCEED 24 INCHES ABOVE THE GROUND SURFACE. (HIGHER FENCES MAY IMPOUND VOLUMES OF WATER SUFFICIENT TO CAUSE FAILURE OF THE STRUCTURE.) 3. CONSTRUCT THE FILTER FABRIC FROM A CONTINUOUS ROLL CUT THE LENGTH OF THE BARRIER TO AVOID JOINTS. WHEN JOINTS ARE NECESSARY, SECURELY FASTEN THE FILTER CLOTH ONLY AT A SUPPORT POST WITH 4 FEET MINIMUM OVERLAP TO THE NEXT POST. 4. SUPPORT STANDARD STRENGTH FILTER FABRIC BY WIRE MESH FASTENED SECURELY TO THE UPSLOPE SIDE OF THE POSTS. EXTEND THE WIRE MESH SUPPORT TO THE BOTTOM OF THE TRENCH. FASTEN THE WIRE REINFORCEMENT, THEN FABRIC ON THE UPSLOPE SIDE OF THE FENCE POST. WIRE OR PLASTIC ZIP TIES SHOULD HAVE A MINIMUM 50 POUND TENSILE STRENGTH. 5. WHEN A WIRE MESH SUPPORT FENCE IS USED, SPACE POSTS A MAXIMUM OF 8 FEET APART. SUPPORT POSTS SHOULD BE DRIVEN SECURELY INTO THE GROUND A MINIMUM OF 24 INCHES. 6. EXTRA STRENGTH FILTER FABRIC WITH 6 FT POST SPACING DOES NOT REQUIRE WIRE MESH SUPPORT FENCE. SECURELY FASTEN THE FILTER FABRIC DIRECTLY TO POSTS. WIRE OR PLASTIC ZIP TIES SHOULD HAVE A MINIMUM 50 POUND TENSILE STRENGTH. 7. EXCAVATE A TRENCH APPROXIMATELY 4 INCHES WIDE AND 8 INCHES DEEP ALONG THE PROPOSED LINE OF POSTS AND UPSLOPE FROM THE BARRIER. 8. PLACE 12 INCHES OF THE FABRIC ALONG THE BOTTOM AND SIDE OF THE TRENCH. 9. BACKFILL THE TRENCH WITH SOIL PLACED OVER THE FILTER FABRIC AND COMPACT. THROUGH COMPACTION OF THE BACKFILL IS CRITICAL TO SILT FENCE PERFORMANCE. 10. DO NOT ATTACH FILTER FABRIC TO EXISTING TREES. MAINTENANCE: INSPECT SEDIMENT FENCES AT LEAST ONCE A WEEK AND AFTER EACH RAINFALL. MAKE ANY REQUIRED REPAIRS IMMEDIATELY. SHOULD THE FABRIC OF A SEDIMENT FENCE COLLAPSE, TEAR, DECOMPOSE OR BECOME INEFFECTIVE, REPLACE IT PROMPTLY. REMOVE SEDIMENT DEPOSITS AS NECESSARY TO PROVIDE ADEQUATE STORAGE VOLUME FOR THE NEXT RAIN AND TO REDUCE PRESSURE ON THE FENCE. TAKE CARE TO AVOID UNDERMINING THE FENCE DURING CLEANOUT. REMOVE ALL FENCING MATERIALS AND UNSTABLE SEDIMENT DEPOSITS AND BRING THE AREA TO GRADE AND STABILIZE IT AFTER THE CONTRIBUTING DRAINAGE AREA HAS BEEN PROPERLY STABILIZED. NOTE: STRUCTURAL STONE SHALL BE (CLASS "B") STONE FOR EROSION CONTROL PURPOSES. SEDIMENT CONTROL STONE SHALL BE #5 OR #57 STONE SILT FENCE 1'-6" MIN. 1 2 �� x �OW ENT CONTROL-' LSTRUCTURAL STONE STONE CROSS SECTION SILT FENCE DETAIL NC DEQ FIGURE 6.62A / NTS 2' TOP VIEW SILT FENCE OUTLET PROJECT INFORMATION PROJECT DESCRIPTION THE PURPOSE OF THE PROJECT IS TO CONSTRUCT A 33 LOT SINGLE-FAMILY HOME SUBDIVISION WITH ASSOCIATED ROADWAYS AND UTILITIES. THE SITE IS LOCATED ON SOUTH JIM MINOR ROAD IN ALAMANCE COUNTY NORTH CAROLINA AND CONSISTS OF 6 SEPARATE PARCELS. THEY CAN BE IDENTIFIED AS PARCEL ID#S 170308, 170309, 170310, 159117, 159114, AND 159116. SITE DESCRIPTION THE 6 PARCELS THAT MAKE UP THE PROJECT TOTAL 43.01 ACRES BY SURVEY. THE TOTAL AREA IS LARGELY VACANT AND WOODED EXCEPT FOR A MOBILE HOME AND SHEDS WITH ASSOCIATED DRIVEWAY WHICH IS LOCATED ON PARCEL ID# 159116. THERE IS A CLEARED 85' WIDE PSNC GAS PIPELINE EASEMENT ON THE NORTH SIDE OF THE PROJECT AND A STREAM RUNNING ALONG THE WEST AND SOUTH SIDES OF THE PROJECT. THE STREAM TO THE SOUTH HAS AN ASSOCIATED FEMA FLOOD PLAIN. NO DEVELOPMENT IS PLANED IN THE VICINITY OF THE STREAM, STREAM BUFFER OR FLOOD PLAIN. THE SITE IS THE REAR HALF OF A PREVIOUSLY DEVELOPED 25.26 ACRE WAREHOUSE FACILITY. THE DEVELOPMENT SITE IS COVERED IN SCRUB PINE AND BRUSH WITH AN EAST WEST RIDGELINE THAT SPLITS DRAINAGE ROUGHLY IN HALF AND DIRECTS RUNOFF TO THE NORTHERN PROPERTY LINES AND SOUTHERN PROPERTY LINES. SLOPES VARY GREATLY ACROSS THE SITE WITH STEEPER SLOPES BEING NEAR THE STREAM. THE SITE DRAINS TO THE SOUTH AND WEST TOWARD THE STREAM. ADJACENT PROPERTY NEIGHBORING PROPERTIES ARE ALL LARGER SIZE SINGLE FAMILY HOME LOTS OR LARGE UNDEVELOPED TRACTS OF LAND. NARRATIVE PLANNED EROSION AND SEDIMENTATION CONTROL PRACTICES 1. SEDIMENT FENCE/ SILT FENCE OUTLETS SEDIMENT FENCE WILL BE CONSTRUCTED ALONG THE DOWNSTREAM PERIMETER OF THE SITE. SILT FENCE OUTLETS ARE PROVIDED AT THE LOW POINTS ALONG THE SEDIMENT FENCE LINE OR ARE POSITIONED WITH SILT FENCE CUT-OFFS TO REDUCE FLOWS ALONG THE SILT FENCE. 2. TEMPORARY DIVERSIONS TEMPORARY DIVERSIONS ARE PROVIDED ALONG THE EDGES OF FILL SLOPES TO DIRECT SEDIMENT LADEN WATER TO THE SEDIMENT BASINS FOR FILTRATION AND TO PREVENT EROSION OF FILL SLOPES AND PREVENT RUNOFF FROM ENTERING THE UNDERGROUND STORAGE CHAMBERS PRIOR TO STABILIZATION OF PARKING FACILITIES. 3. INLET PROTECTION INLET PROTECTION IS PROVIDED AT ALL ENTRANCES TO THE STORM SEWER SYSTEM TO PREVENT SEDIMENTATION OF THE PROPOSED UNDERGROUND STORAGE PIPES. 4. CONSTRUCTION ENTRANCE/EXIT A TEMPORARY CONSTRUCTION ENTRANCE/EXIT WILL BE CONSTRUCTED OFF OF SPRING FOREST DRIVE IN THE LOCATION OF THE PERMANENT ENTRANCE. 5. RIP RAP APRON PERMANENT STABILIZATION WILL BE INSTALLED BELOW PIPE OR FLUME OUTLETS AS INDICATED. 6. SKIMMER SEDIMENT BASINS TWO SKIMMER SEDIMENT BASINS ARE PROVIDED AT THE LOW POINTS OF THE SITE TO FILTER SEDIMENT LADEN RUNOFF PRIOR TO DISCHARGE. CONSTRUCTION SCHEDULE 1. OBTAIN PLAN APPROVAL AND OTHER APPLICABLE PERMITS. 2. HOLD PRECONSTRUCTION CONFERENCE PRIOR TO STARTING CONSTRUCTION. 3. CLEAR AS NECESSARY TO INSTALL PERIMETER MEASURES, CONSTRUCTION ENTRANCE/EXIT, TEMPORARY DIVERSIONS AND SEDIMENT TRAPS/BASINS ABOVE CULVERTS 1, 3 AND 4 AS SHOWN ON SHEET C4.0. 4. INSTALL PERIMETER MEASURES, CONSTRUCTION ENTRANCE/EXIT, AND SEDIMENT TRAPS/BASINS ABOVE CULVERTS 1, 3, AND 4 AS SHOWN ON SHEET C4.0. 5. INSTALL TEMPORARY DIVERSIONS AROUND CULVERTS 1, 3, AND 4 TO DIRECT CLEAN RUNOFF AROUND CONSTRUCTION WHILE CULVERTS ARE BEING INSTALLED. 6. INSTALL ALL CULVERTS AND ASSOCIATED INLETS. INSTALL INLET PROTECTION AS NOTED. 7. PROCEED TO AREA BEYOND CULVERTS AS SHOWN ON SHEET C4.1. 8. CLEAR AS NEEDED TO INSTALL REMAINING PERIMETER MEASURES, DIVERSIONS AND TRAPS. 9. CLEAR AND STRIP REMAINDER OF SITE. 10. ROUGH GRADE NEW ROADWAY AND PRIVATE DRIVE. 11. UPON COMPLETION OF FILL, STABILIZE BACKSLOPES IMMEDIATELY. 12. INSTALL WATERMAIN IN SOUTH JIM MINOR ROAD. STABILIZE DISTURBED AREAS ON THE NORTHERN SIDE OF SOUTH JIM MINOR ROAD IMMEDIATELY. 13. EXTEND WATERMAIN ALONG NEW ROADWAY. TEST AND CHLORINATE PRIOR TO FINE GRADING ROADWAY. 14. GRADE SUBGRADE OF ROADWAY AND PRIVATE DRIVE. 15. INSTALL BASE AND PAVING. 16. FINE GRADE FILL SLOPES AND DITCHES. INSTALL TEMPORARY LINERS AS NOTED. 17. INSTALL PERMANENT APRONS AND STABILIZE ALL REMAINING DISTURBED AREAS. 18. INSPECT ALL EROSION AND SEDIMENT CONTROL PRACTICES WEEKLY AND AFTER RAINFALL EVENTS. MAKE NEEDED REPAIRS IMMEDIATELY. 19. AFTER SITE IS STABILIZED, REMOVE ALL TEMPORARY EROSION CONTROL MEASURES AND INSTALL PERMANENT VEGETATION ON THE DISTURBED AREAS. MAINTENANCE PLAN 1. CHECK ALL EROSION AND SEDIMENT CONTROL PRACTICES FOR STABILITY AND OPERATION FOLLOWING EVERY RAINFALL PRODUCING RUNOFF BUT IN NO CASE LESS THAN ONCE EVERY WEEK. MAKE ANY NEEDED REPAIRS IMMEDIATELY TO MAINTAIN ALL PRACTICES AS DESIGNED. FOLLOW ALL REQUIREMENTS OF NPDES PHASE II PERMIT. 2. REMOVE SEDIMENT FROM BEHIND SILT FENCE OUTLETS AND STONE FILTERS WHEN STORAGE CAPACITY HAS BEEN APPROXIMATELY 50% FILLED. CLEAN OR REPLACE GRAVEL ON OUTLETS WHEN THE WATER POOLS AND IS NO LONGER DRAINING PROPERLY. 3. CLEAN TRAPS WHEN SEDIMENT ACCUMULATES TO WITHIN ONE FOOT OF THE WEIR CREST ELEVATION. CHECK TRAPS FOR EVIDENCE OF BYPASS OR BREACH AFTER EACH RAINFALL AND REPAIR IMMEDIATELY. 4. SEED AND STABILIZE ALL DISTURBED AREAS IN ACCORDANCE WITH STABILIZATION TABLE PRESENTED ON THIS SHEET. C� U o O U 'i CU W y-- T m U N CN ,l! C) O co Co m:t 0 U �C\JLoCo O UmmY U � z T T N * 0 )��� a > C: N Cz �--� U O x � O CU Cz W iD CV 0- LL_ W cc W N W N Z ZIL W Z Z Q 0 _ U U Z� .J d 0 0 0 L) mIUUUU J z O z Lu p[ w 2 2 z O O O 0 U Z U U O co or- oOo= w wwocw o 0- o= w 0- rn rn rn rn w o 0 0 0 N N N N N f,- f,- O O O O r � r N co � DATE: AUGUST 29, 2018 HORIZONTAL SCALE: N/A VERTICAL SCALE: N/A PROJECT MANAGER: CPK DRAWN BY: SCS PROJECT NO: 17-002 DRAWING NAME: 17-002 DETAILS THIS DRAWING AND THE DESIGN HEREON ARE THE PROPERTY OF EarthCentric Engineering, Inc. THE INFORMATION ON THIS DRAWING IS NOT FOR USE ON ANY OTHER SITE OR PROJECT. THE REPRODUCTION OR OTHER USE OF THIS DRAWING IN WHOLE OR IN PART, WITHOUT WRITTEN CONSENT OF EarthCentric Engineering, Inc., IS PROHIBITED. COPYRIGHT 2019 EarthCentric Engineering, Inc. SHEET NO. P:\17-002\17-002 Drawings\6. Rev04\17-002 Details.dwg, D1.2 EC Details, 10/16/2019 2:23:57 PM PRELIMINARY SUBDIVISION PLAN rANULL Iu#J I /UJU0, I /UJU'J, I /U,7I U, 1 5y I 1 4, 15y1 1 b, 1 5y11 / \ \ o i \ \ \\ \ / NATURAL GROUND CLASS B RIPRAP E / RIP RAP HEADWALL FILTER BERM NCDOT #5 OR #57 WASHED STONE �C) �v I PERSPECTIVE VIEW NO SCALE PIPE INVERT AREAS TO BE DISTURBED SEDIMENT STORAGE NOTE: (CUT, FILL, ETC.) FLOOD STORAGE ZONE RIP RAP HEADWALL, 1' MIN GRAVEL &RIP RAP FILTER BERM HEIGHT FROM ROAD SHOULDER BASIN DETAIL IS DESIGNED TO 1' 3' 1firt --u,i NATURAL PROTECT EXISTING PIPE INVERTS FLOW 2 3 - - GROUND THAT DRAIN 10 ACRES OR LESS. eue = C - 6RIP-RAP FLOWS - - h -iii-------- 1.5' e - - DIMENSIONS ARE MINIMUM LASS ACCEPTABLE UNLESS NCDOT #5 OR #57 WASHED STONE OTHERWISE NOTED. MAX. SEDIMENT DEPTH(CLEAN OUT POINT) SECTION THRU BASIN, FILTER AND CULVERT PIPE NO SCALE (EXISTING PIPE INVERTS) STD. No. ROCK PIPE INLET PROTECTION 6.55.2 _ TOP ELEVATION OF STORM WATER ---------------------- #57 WASHED DESIGN OF SPILLWAYS STONE- 1 EXISTING SLOPE t DRAINAGE _„- AREA WEIR LENGTH (ACRES) (FT) 1 4.0 2 6.0 3 8.0 4 10.0 5 12.0 1DIMENSIONS SHOWN ARE MINIMUM mm, CLASS 1 RIP -RAP FILTER FABRIC SIDE VIEW �/-37//VG�E �P STEP SEQUENCE FRONT VIEW NOTE: REVISIONS HEIGHT &WIDTH DETERMINED BY EXISTING DATE DESCRIPTION TOPOGRAPHY AND SEDIMENT STORAGE REQUIRED. 10/88 NOTE ADDITION M.H.D. 4/96 ADD SPILLWAY CHART G.M.A. KEY RIP RAP INTO THE DAM FOR STABILIZATION. STD. No. CHECK DAM 4.06 -DEWATERING CONCRETE BLOCK 000�0 ON a °� °�0 z �@10 0 w m g g - - �o O -� O 00 cO °0 QD 0�� �� �� 0 0 00 o �° g °� O° ° 0OC6 0 o°Oo0oo 0 0 �� o 0 o°O O 0 00 (3 o 0 00 8000 0 ° 0 O 0o E0 o� ° �0 o gg @o b O �o 0 o g°O@ Cop Oocaa�®o��°oO��OQ,� 2:1 SLOPE, GRAVEL FILTER 4' MIN. ALL AROUND WIRE SCREEN TEMPORARY SEDIMENT POOL DEWATERING 1' MIN. 2' MAX. DRAINAGE - SEDIMENT 1I 11IIII- STRUCTURE CONSTRUCTION SPECIFICATIONS 1. LAY ONE BLOCK ON EACH SIDE OF THE STRUCTURE ON ITS SIDE IN THE BOTTOM ROW TO ALLOW POOL DRAINAGE. THE FOUNDATION SHOULD BE EXCAVATED AT LEAST 2 INCHES BELOW THE CREST OF THE STORM DRAIN. PLACE THE BOTTOM ROW OF BLOCKS AGAINST THE EDGE OF THE STORM DRAIN FOR LATERAL SUPPORT AND TO AVOID WASHOUTS WHEN OVERFLOW OCCURS. IF NEEDED, GIVE LATERAL SUPPORT TO SUBSEQUENT ROWS BY PLACING 2 X 4 WOOD STUDS THROUGH BLOCK OPENINGS. 2. CAREFULLY FIT HARDWARE CLOTH OR COMPARABLE WIRE MESH WITH 1/2-INCH OPENINGS OVER ALL BLOCK OPENINGS TO HOLD GRAVEL IN PLACE. 3. USE CLEAN GRAVEL, 3/4- TO 1/2-INCH IN DIAMETER, PLACED 2 INCHES BELOW THE TOP OF THE BLOCK ON A 2:1 SLOPE OR FLATTER AND SMOOTH IT TO AN EVEN GRADE. DOT #57 WASHED STONE IS RECOMMENDED. 4. IF ONLY STONE AND GRAVEL ARE USED, KEEP THE SLOPE TOWARD THE INLET NO STEEPER THAN 3:1. LEAVE A MINIMUM 1-FT WIDE LEVEL STONE AREA BETWEEN THE STRUCTURE AND AROUND THE INLET TO PREVENT GRAVEL FROM ENTERING INLET. ON THE SLOPE TOWARD THE INLET, USE STONE 3 INCHES IN DIAMETER OR LARGER. ON THE SLOPE AWAY FROM THE INLET USE 1/2 - 3/4-INCH GRAVEL (NCDOT #57 WASHED STONE) AT A MINIMUM THICKNESS OF 1 FT. MAINTENANCE INSPECT THE BARRIER AFTER EACH RAIN AND MAKE REPAIRS AS NEEDED. REMOVE SEDIMENT AS NECESSARY TO PROVIDE ADEQUATE STORAGE VOLUME FOR SUBSEQUENT RAINS. WHEN THE CONTRIBUTING DRAINAGE AREA HAS BEEN ADEQUATELY STABILIZED, REMOVE ALL MATERIALS AND ANY UNSTABLE SOIL, AND EITHER SALVAGE OR DISPOSE OF IT PROPERLY. BRING THE DISTURBED AREA TO PROPER GRADE, THEN SMOOTH AND COMPACT IT. APPROPRIATELY STABILIZE ALL BARE AREAS AROUND THE INLET. BLOCK AND GRAVEL INLET PROTECTION NTS SEE DENR STANDARDS & SPECS. FOR COMPLETE DESIGN CRITERIA & MAINTENANCE PVC END CAP \ PVC ELBOW WATER SURFACE PVC VENT PIPE \ •• PVC END CAP SCHEDULE 40 PVC PIPE PVC TEE FLEXIBLE PVC PIPE 1/2" HOLES IN HOSE UNDERSIDE END VIEW SKIMMER SEDIMENT BASINS ARE NEEDED WHERE DRAINAGE AREAS ARE TOO LARGE FOR TEMPORARY TRAPS. DO NOT LOCATE THE SKIMMER SEDIMENT BASIN IN INTERMITTENT OR PERENNIAL STREAMS. M Arrl r fTWMN INLE INLET ZONE 25% OF SURFACE AREA SCHEDULE 40 PVC PIPE ORIFICE PLATE PVC TEE BOTTOM SURFACE FRONT VIEW "C" ENCLOSURE WATER ENTRY UNIT TLET OUTLET ZONE 25% OF SURFACE AREA SURFACE AREA SURFACE AREA POROUS BAFFLES IN SEDIMENT TRAP , BASIN SUPPORT ROPE TO WIRE TO PREVENT SAGGING SUPPORT POST, 24" INTO BOTTOM OR SIDE STAKE TO SUPPORT WIRE I COIR MESH OR SIMILAR, STAPLED OR TRENCHED INTO BOTTOM OR SIDE CROSS-SECTION OF POROUS BAFFLES CONSTRUCTION SPECIFICATION: 1. GRADE THE BASIN SO THAT THE BOTTOM IS LEVEL FRONT TO BACK AND SIDE TO SIDE. 2. INSTALL POSTS ACROSS THE WIDTH OF THE SEDIMENT TRAP (PRACTICE 6.62, SEDIMENT FENCE). 3. STEEL POSTS SHOULD BE DRIVEN TO A DEPTH OF 24 INCHES, SPACED A MAXIMUM OF 4 FEET APART, AND INSTALLED UP THE SIDES OF THE BASIN AS WELL. THE TOP OF THE FABRIC SHOULD BE 6 INCHES HIGHER THAT THE INVERT OF THE SPILLWAY. TOPS OF BAFFLES SHOULD BE 2 INCHES LOWER THAN THE TOP OF THE BERMS. 4. INSTALL AT LEAST THREE ROWS OF BAFFLES BETWEEN THE INLET AND THE OUTLET DISCHARGE POINT. BASINS LESS THAN 20 FEET IN LENGTH MAY USE 2 BAFFLES. 5. ADD A SUPPORT WIRE OR ROPE ACROSS THE TOP OF THE MEASURE TO PREVENT SAGGING. 6. WRAP POROUS MATERIAL, LIKE JUTE BACKED BY COIR MATERIAL, OVER THE TOP WIRE. THE FABRIC SHOULD HAVE FIVE TO TEN PERCENT OPENINGS IN THE WEAVE. ATTACH FABRIC TO A ROPE AND A SUPPORT STRUCTURE WITH ZIP TIES, WIRE, OR STAPLES. 7. THE BOTTOM AND SIDES OF THE FABRIC SHOULD BE ANCHORED IN A TRENCH OR PINNED WITH 8-INCH EROSION CONTROL MATING STAPLES. 8. DO NOT SPLICE THE FABRIC, BUT USE A CONTINUOUS PIECE ACROSS THE BASIN MAINTENANCE INSPECT BAFFLES AT LEAST ONCE A WEEK AND AFTER EACH RAINFALL. MAKE ANY REQUIRED REPAIRS IMMEDIATELY. BE SURE TO MAINTAIN ACCESS TO THE BAFFLES. SHOULD THE FABRIC OF A BAFFLE COLLAPSE, TEAR, DECOMPOSE, OR BECOME INEFFECTIVE, REPLACE IT PROMPTLY. REMOVE SEDIMENT DEPOSITS WHEN IT REACHES HALF FULL TO PROVIDE ADEQUATE STORAGE VOLUME FOR THE NEXT RAIN AND TO REDUCE PRESSURE ON THE BAFFLES. TAKE CARE TO AVOID DAMAGING THE BAFFLES DURING CLEANOUT. SEDIMENT DEPTH SHOULD NEVER EXCEED HALF THE DESIGNED STORAGE DEPTH. AFTER THE CONTRIBUTING DRAINAGE AREA HAS BEEN PROPERLY STABILIZED, REMOVE ALL BAFFLE MATERIALS AND UNSTABLE SEDIMENT DEPOSITS, BRING THE AREA TO GRADE, AND STABILIZE IT. POROUS BAFFLES INFLOW STRUCTURE AVERAGE_ AREA* WIDTH W - L * AREA OF BASIN WATER SURFACE AT TOP OF PRINCIPAL SPILLWAY ELEVATION INFLOW STRUCTURE BAFFLES DEWATERING ZONE FILTER FABRIC PLAN VIEW BAFFLES SKIMMER DEWATERING DEVICE w U z a z bi vi z_ wa 0- :2 V)48 c�3 Q V)E oC) z U �z V� 0,� W z0 Ww o� W W W J Na O U tY O LL EMERGENCY SPILLWAY EMBANKMENT 1' FREEBOARD / Z� 6" MIN. INVE T ELEVATION OF EMERGENCY SPILLWAY EMERGENCY SPILLWAY SEDIMENT STORAGE ZONE CROSS-SECTION VIEW CONSTRUCTION SPECIFICATIONS: 1. CLEAR, GRUB, AND STRIP THE AREA UNDER THE EMBANKMENT OD ALL VEGETATION AND ROOT MATERIAL. REMOVE ALL SURFACE SOIL CONTAINING HIGH AMOUNTS OF ORGANIC MATTER AND STOCKPILE OR DISPOSE OF IT PROPERLY. HAUL ALL OBJECTIONABLE MATERIAL TO THE DESIGNATED DISPOSAL AREA. PLACE TEMPORARY SEDIMENT CONTROL MEASURES BELOW BASIN AS NEEDED. 2. ENSURE THAT FILL MATERIAL FOR THE EMBANKMENT IS FREE OF ROOTS, WOODY VEGETATION, ORGANIC MATTER, AND OTHER OBJECTIONABLE MATERIAL. PLACE THE FILL IN LIFTS NOT TO EXCEED 9 INCHES, AND MACHINE COMPACT IT. OVER FILL THE EMBANKMENT 6 INCHES TO ALLOW FOR SETTLEMENT. 3. SHAPE THE BASIN TO THE SPECIFIED DIMENSIONS. PREVENT THE SKIMMING DEVICE FROM SETTLING INTO THE MUD BY EXCAVATING A SHALLOW PIT UNDER THE SKIMMER OR PROVIDING A LOW SUPPORT UNDER THE SKIMMER OF STONE OR TIMBER. 4. PLACE THE BARREL (TYPICALLY 4-INCH SCHEDULE 40 PVC PIPE) ON A FIRM, SMOOTH FOUNDATION OF IMPERVIOUS SOIL. DO NOT USE PERVIOUS MATERIAL SUCH AS SAND, GRAVEL, OR CRUSHED STONE AS BACKFILL AROUND THE PIPE. PLACE THE FILL MATERIAL AROUND THE PIPE SPILLWAY IN 4-INCH LAYERS AND COMPACT IT UNDER AND AROUND THE PIPE TO AT LEAST THE SAME DENSITY AS THE ADJACENT EMBANKMENT. CARE MUST BE TAKEN TO RAISE THE PIPE FROM THE FIRM CONTACT WITH ITS FOUNDATION WHEN COMPACTING UNDER THE PIPE HAUNCHES. PLACE A MINIMUM DEPTH OF 2 FEET OF COMPACTED BACKFILL OVER THE PIPE SPILLWAY BEFORE CROSSING IT WITH CONSTRUCTION EQUIPMENT. IN NO CASE SHOULD THE PIPE CONDUIT BE INSTALLED BY CUTTING A TRENCH THROUGH THE DAM AFTER THE EMBANKMENT IS COMPLETE. 5. ASSEMBLE THE SKIMMER FOLLOWING THE MANUFACTURERS INSTRUCTIONS, OR AS DESIGNED. 6. LAY THE ASSEMBLED SKIMMER ON THE BOTTOM OF THE BASIN WITH THE FLEXIBLE JOINT AT THE INLET OF THE BARREL PIPE. ATTACH THE FLEXIBLE JOINT TO THE BARREL PIPE AND POSITION THE SKIMMER OVER THE EXCAVATED PIT OR SUPPORT. BE SURE TO ATTACH A ROPE TO THE SKIMMER AND ANCHOR IT TO THE SIDE OF THE BASIN. THIS WILL BE USED TO PULL THE SKIMMER TO THE SIDE FOR MAINTENANCE. 7. EARTHEN SPILLWAYS - INSTALL THE SPILLWAY IN UNDISTURBED SOIL TO THE GREATEST EXTENT POSSIBLE. THE ACHIEVEMENT OF PLANNED ELEVATIONS, GRADE, DESIGN WIDTH, AND ENTRANCE AND EXIT CHANNEL SLOPES ARE CRITICAL TO THE SUCCESSFUL OPERATION OF THE SPILLWAY. THE SPILLWAY SHOULD BE LINED WITH LAMINATED PLASTIC OR IMPERMEABLE GEOTEXTILE FABRIC. THE FABRIC MUST BE WIDE AND LONG ENOUGH TO COVER THE BOTTOM AND SIDES AND EXTEND TO THE TOP OF THE DAM FOR ANCHORING IN A TRENCH. THE EDGES MAY BE SECURED WITH 8-INCH STAPLES OR PINS. THE FABRIC MUST BE LONG ENOUGH TO EXTEND DOWN THE SLOPE AND EXIT ONTO STABLE GROUND. THE WIDTH OF THE FABRIC MUST BE ONE PIECE, NOT JOINED OR SPLICED; OTHERWISE WATER CAN GET UNDER THE FABRIC. IF THE LENGTH OF THE FABRIC IS INSUFFICIENT FOR THE ENTIRE LENGTH OF THE SPILLWAY, MULTIPLE SECTIONS, SPANNING THE COMPLETE WIDTH, MAY BE USED. THE UPPER SECTIONS) SHOULD OVERLAP THE LOWER SECTIONS) SO THAT WATER CANNOT FLOW UNDER THE FABRIC. SECURE THE UPPER EDGE AND SIDES OF THE FABRIC IN A TRENCH WITH STAPLES OR PINS. (ADAPTED FROM "A MANUAL FOR DESIGNING, INSTALLING AND MAINTAINING SKIMMER SEDIMENT BASINS." FEBRUARY, 1999. J.W. FAIRCLOTH & SON). 8. INLETS - DISCHARGE WATER INTO THE BASIN IN A MANNER TO PREVENT EROSION. USE TEMPORARY SLOPE DRAINS OR DIVERSIONS WITH OUTLET PROTECTION TO DIVERT SEDIMENT LADEN WATER TO THE UPPER END OF THE POOL AREA TO IMPROVE BASIN TRAP EFFICIENCY (REFERENCES: RUNOFF CONTROL MEASURES AND OUTLET PROTECTION). 9. EROSION CONTROL - CONSTRUCT THE STRUCTURE SO THAT THE DISTURBED AREA IS MINIMIZED. DIVERT SURFACE WATER AWAY FROM BARE AREAS. COMPLETE THE EMBANKMENT BEFORE AREA IS CLEARED. STABILIZE THE EMERGENCY SPILLWAY EMBANKMENT AND ALL OTHER DISTURBED AREA ABOVE THE CREST OF THE PRINCIPAL SPILLWAY IMMEDIATELY AFTER CONSTRUCTION (REFERENCES: SURFACE AND STABILIZATION). 10. INSTALL POROUS BAFFLES AS SPECIFIED IN PRACTICE 6.65, POROUS BAFFLES. 11. AFTER ALL THE SEDIMENT -PRODUCING AREAS HAVE BEEN PERMANENTLY STABILIZED, REMOVE THE STRUCTURE AND ALL THE INSTABLE SEDIMENT. SMOOTH THE AREA TO BLEND WITH THE ADJOINING AREAS AND STABILIZE PROPERLY (REFERENCES: SURFACE STABILIZATION). MAINTENANCE: INSPECT SKIMMER SEDIMENT BASINS AT LEAST WEEKLY AND AFTER EACH SIGNIFICANT (ONE-HALH INCH OR GREATER) RAINFALL EVENT AND REPAIR IMMEDIATELY. REMOVE SEDIMENT AND RESTORE THE BASIN TO ITS ORIGINAL DIMENSIONS WHEN SEDIMENT ACCUMULATES TO ONE-HALF THE HEIGHT OF THE FIRST BAFFLE. PULL THE SKIMMER TO ONE SIDE SO THAT THE SEDIMENT UNDERNEATH IT CAN BE EXCAVATED. EXCAVATE THE SEDIMENT FROM THE ENTIRE BASIN, NOT JUST AROUND THE SKIMMER OR THE FIRST CELL. MAKE SURE VEGETATION GROWING IN THE BOTTOM OF THE BASIN DOES NOT HOLD DOWN THE SKIMMER. REPAIR THE BAFFLES IF THEY ARE DAMAGED. RE -ANCHOR THE BAFFLES IF WATER IS FLOWING UNDERNEATH OR AROUND THEM. IF THE SKIMMER IS CLOGGED WITH TRASH AND THERE IS WATER IN THE BASIN, USUALLY JERKING ON THE ROPE WILL MAKE THE SKIMMER BOB UP AND DOWN AND DISLODGE THE DEBRIS AND RESTORE FLOW. IF THIS DOES NOT WORK, PULL THE SKIMMER OVER TO THE SIDE OF THE BASIN AND REMOVE THE DEBRIS. ALSO CHECK THE ORIFICE INSIDE THE SKIMMER TO SEE ID IT IS CLOGGED; IF SO REMOVE THE DEBRIS. IF THE SKIMMER ARM OR BARREL PIPE IS CLOGGED, THE ORIFICE CAN BE REMOVED AND THE OBSTRUCTION CLEARED WITH A PLUMBER'S SNAKE OR BY FLUSHING WITH WATER. BE SURE AND REPLACE THE ORIFICE BEFORE REPOSITIONING THE SKIMMER. CHECK THE FABRIC LINED SPILLWAY FOR DAMAGE AND MAKE ANY REQUIRED REPAIRS WITH FABRIC THAT SPANS THE FULL WIDTH OF THE SPILLWAY. CHECK THE EMBANKMENT, SPILLWAYS, AND OUTLET FOR EROSION DAMAGE, AND INSPECT THE EMBANKMENT FOR PIPING AND SETTLEMENT. MAKE ALL NECESSARY REPAIRS IMMEDIATELY. REMOVE ALL TRASH AND OTHER DEBRIS FROM THE SKIMMER AND POOL AREAS. FREEZING WEATHER CAN RESULT IN ICE FORMING IN THE BASIN. SOME SPECIAL PRECAUTIONS SHOULD BE TAKEN IN THE WINTER TO PREVENT THE SKIMMER FROM PLUGGING WITH ICE. SKIMMER SEDIMENT BASIN U C: E O O 'i Lu r t Cz U �Nm��j a) OCO m:t C9 0 U �CuLOCO O U a� a� Y U � z T T N U CZ Cz Cz U CC 0 x G O N Cz W -j ND- LLW CC w N W � Z W Z CL U Z _J , Q = 0 U U Z_ � EE .J CL _ mIUUUU J z O z Lu p[ Lu z O O OU z U 0U O Lu E75 cooc o O oc Lu Lu Lu = Lu o 0- Lu 0- 0') rn rn rn Lu o 0 0 0 N N N N 0 �_ co co r­ r­ CD 0 CD CD r > � r N co � DATE: AUGUST 29, 2018 HORIZONTAL SCALE: N/A VERTICAL SCALE: N/A PROJECT MANAGER: CPK DRAWN BY: SCS PROJECT NO: 17-002 DRAWING NAME: 17-002 DETAILS THIS DRAWING AND THE DESIGN HEREON ARE THE PROPERTY OF EarthCentric Engineering, Inc. THE INFORMATION ON THIS DRAWING IS NOT FOR USE ON ANY OTHER SITE OR PROJECT. THE REPRODUCTION OR OTHER USE OF THIS DRAWING IN WHOLE OR IN PART, WITHOUT WRITTEN CONSENT OF EarthCentric Engineering, Inc., IS PROHIBITED. COPYRIGHT 2019 EarthCentric Engineering, Inc. SHEET NO. D 1 0 QO) PRELIMINARY SUBDIVISION PLAN A17-002\17-002 Drawings\6. Rev04\17-002 Details.dwg, D1.3 EC Details, 10/16/2019 2:23:59 PM FANULL IU#J I /UJU0, I /UJU'J, I /U,S I U, 1 5y I 1 4, 15y1 1 b, 1 5y11 / APRON WIDTH AT THE OUTLET IS 1.5 TIMES THE WIDTH OF THE F.E.S. FLARED END SECTION APRON LENGTH RIP —RAP PLAN VIEW LENGTH OF APRON FLOC SLOPE OF EXISTING L\ SECTION A —A THERE MUST BE NO OVERALL AT THE END OF THE APRON. WHEN THE AREA BELOW THE OUTLET IS NOT A DEFINED CHANNEL, BUILD A FLAT APRON TO DISPERSE RUNOFF. FILTER BLANKET SECTION B—B TTAERE A DEFIRED CAAAREL EXISTS, THE CHANNEL. IF NECESSARY, LINE THE ENTRANCE TO PROVIDE A TRANSITION INTO THE RECEIVING CHANNEL. •-, t t.- • APRONDEPTH OF I STONE FILTER SECTION B—B INSTRUCTIONS FOR RIP RAP APRON / STONE APRON OUTLET PROTECTION INSTALLATION 1. REFER TO THE PLANS FOR LOCATION, EXTENT, AND SPECIFICATIONS. IF THERE ARE QUESTIONS OR PROBLEMS WITH THE LOCATION, EXTENT, OR METHOD OF INSTALLATION, CONTACT THE ENGINEER, ARCHITECT, OR RESPONSIBLE PERSONNEL ON THE SITE FOR ASSISTANCE. EROSION CONTROL PERSONNEL HAVE COPIES OF INSTRUCTIONS AND MAY HAVE PHOTOGRAPHS OR PROPERLY INSTALLED APRONS AS A AID TO INSTALLATION. IF THE STONE APRON IS NOT INSTALLED CORRECTLY THE FIRST TIME, IT WILL HAVE TO BE REBUILT. 2. DETERMINE THE LOCATION ON THE GROUND TAKING INTO CONSIDERATION: * DECIDE HOW EQUIPMENT AND MATERIAL WILL REACH THE LOCATION TO CONSTRUCT THE APRON. DO NOT "PAINT YOURSELF INTO A CORNER" AND PLACE FILL, STRUCTURES, ETC. THAT COULD BLOCK ACCESS. * THE LOCATION OF THE APRON MUST BE SOLID GROUND. IT MAY BE NECESSARY TO EXCAVATE THE LOCATION TO REMOVE MUD AND THEN BACKFILL WITH GOOD MATERIAL. THIS IS NECESSARY SO THE STONE DOES NOT DISAPPEAR INTO THE MUD, WHICH WOULD REQUIRE MUCH MORE STONE TO COMPLETE THE APRON AND MAKE INSTALLATION DIFFICULT. 3. CLEAR THE LOCATION OF THE APRON. LEAVE AS MUCH OF THE EXISTING VEGETATION AS POSSIBLE AROUND THE LOCATION TO HOLD THE SOIL IN PLACE AND REDUCE THE AREA THAT WILL HAVE TO BE STABILIZED AFTERWARD. 4. EXCAVATE THE BOTTOM TO THE REQUIRED DEPTH TO ACCEPT THE STONE AND THE FILTER BLANKET. WHEN FINISHED, THE BOTTOM OF THE APRON MUST BE LEVEL WITH THE BOTTOM OF THE CHANNEL; THERE CANNOT BE AN OVERALL AT THE END OF THE APRON. 5. PLACE THE FILTER BLANKET, AS SPECIFIED IN THE PLAN, OVER THE LOCATION AND UNDER THE LIP OF THE FLARED END SECTION. 6. PLACE THE SPECIFIED STONE TO THE REQUIRED DIMENSIONS AND SHAPE IT TO THE CONFIGURATION SHOWN IN THE PLAN. 7. STABILIZE THE AREA AROUND THE APRON THAT WAS DISTURBED DURING CONSTRUCTION. USE ADDITIONAL STONE OR VEGETATION, WHICHEVER IS APPROPRIATE FOR THE SITUATION. RIP RAP APRON NTS ;OLL OUT STRIPS OF NETTING PARALLEL TO THE DIRECTION OF FLOW AND OVER THE PROTECTIVE MULCH �B3 N o��R�90 I TRENCH JOIN STRIPS BY ANCHORING AND OVERLAPPING. INSTALLATION OF NETTING AND MATTING PRODUCTS DESIGNED TO CONTROL EROSION SHOULD BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. ANY MAT OR BLANKET -TYPE PRODUCT USED AS A PROTECTIVE MULCH SHOULD PROVIDE COVER OF AT LEAST 30% OF THE SURFACE WHERE IT IS APPLIED. 1. APPLY LIME, FERTILIZER AND SEED BEFORE LAYING THE NET OR MAT. 2. START LAYING THE NET FROM THE TOP OF THE CHANNEL OR SLOPE AND UNROLL IT DOWN THE GRADE. ALLOW NETTING TO LAY LOOSELY ON THE SOIL BUT WITHOUT WRINKLES - DO NOT STRETCH. 3. TO SECURE THE NET, BURY THE UPSLOPE END IN A SLOT OR TRENCH NO LESS THAN 6 INCHES DEEP, COVER WITH SOIL, AND TAMP FIRMLY. STAPLE THE NET EVERY 12 INCHES ACROSS THE TOP END AND EVERY 3 FEET AROUND THE EDGES AND BOTTOM. WHERE 2 STRIPS OF NET ARE LAID SIDE BY SIDE, THE ADJACENT EDGES SHOULD BE OVERLAPPED 3 INCHES AND STAPLED TOGETHER. EACH STRIP OF NETTING SHOULD ALSO BE STAPLED DOWN THE CENTER, EVERY 3 FEET. DO NOT STRETCH THE NET WHEN APPLYING STAPLES. 4. TO JOIN TWO STRIPS, CUT A TRENCH TO ANCHOR THE END OF THE NEW NET. OVERLAP THE END OF THE PREVIOUS ROLL 18 INCHES AND STAPLE EVERY 12 INCHES JUST BELOW THE ANCHOR SLOT. IT, I1IzIN21zI1z1• 2 INSPECT ALL MULCHES PERIODICALLY, AND AFTER RAINSTORMS TO CHECK FOR RILL EROSION, DISLOCATION, OR FAILURE. WHERE EROSION IS OBSERVED, APPLY ADDITIONAL MULCH. IF WASHOUT OCCURS, REPAIR THE SLOPE GRADE, RESEED, AND REINSTALL MULCH. CONTINUE INSPECTIONS UNTIL VEGETATION IS FIRMLY ESTABLISHED. NETS AND MATS PERMANENT SEEDING SCHEDULE: d SEEDING MIXTURE: ° SPECIES RATE (LB/AC) TALL FESCUE 80 SERICEA LESPEDEZA 20 KOBE LESPEDEZA 10 u SEEDING NOTES: 1. AFTER AUGUST 15, USE UN -SCARIFIED SERICEA SEED. 2. WHERE PERIODIC MOWING IS PLANNED OR A NEAT APPEARANCE IS DESIRED, OMIT -i SERICEA AND INCREASE KOBE LESPEDEZA TO 40 LB/ACRE. ^^,, �U 3. TO EXTEND SPRING SEEDING DATES INTO JUNE, ADD 15 LB/ACRE HULLED BERMUDA ^W GRASS. HOWEVER, AFTER MID-APRIL IT IS PREFERABLE TO SEED TEMPORARY W �j COVER. NURSE PLANTS: Q� BETWEEN MAY 1 AND AUG. 15, ADD 10 LB/ACRE GERMAN MILLET OF 15 LB/ACRE SUDAN GRASS. PRIOR TO MAY 1 OR AFTER AUG. 15 ADD 40 LB/ACRE RYE (GRAIN). ui T 1:t L SEEDING DATES: :t Co Cz BEST POSSIBLE O CV LJJ FALL: AUG. 25 - SEPT. 15 AUG. 20 - OCT. 25 - Co C� LATE WINTER: FEB. 15 - MAR. 21 FEB. 1 - APR. 15 �OCC)C) U FALL IS BEST FOR TALL FESCUE AND LATE WINTER FOR LESPEDEZAS. (n CV Lo Co O U Y SOIL AMENDMENTS: 00 m m C') CZ Z T T APPLY LIME AND FERTILIZER ACCORDING TO SOIL TESTS, OR APPLY 4,000 LB/ACRE N U GROUND AGRICULTURAL LIMESTONE AND 1,000 LB/ACRE 10-10-10 FERTILIZER, EXCEPT, APPLY NO FERTILIZER TO AREAS WITHIN THE NEUSE RIVER RIPARIAN BUFFERS. —_ L m > CZ Cz MULCH: c APPLY 4,000 LB/ACRE GRAIN STRAW OR EQUIVALENT COVER OF ANOTHER SUITABLE 1 1 1 LJJ ci O Cif N 0- ILL. W MULCH. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING, OR ROVING OR BY _j CRIMPING WITH A MULCH ANCHORING TOOL. A DISK WITH BLADES NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. TEMPORARY SEEDING SCHEDULES TABLE 6-10A: TEMPORARY SEEDING RECOMMENDATIONS FOR LATE WINTER AND EARLY SPRING SEEDING MIXTURE SPECIES RATE (LB/ACRE) RYE (GRAIN) 120 ANNUAL LESPEDEZA (KOBE IN PIEDMONT AND COASTAL PLAIN, KOREAN IN MOUNTAINS) 50 OMIT ANNUAL LESPEDEZA WHEN DURATION OF TEMPORARY COVER IS NOT TO EXTEND BEYOND JUNE. SEEDING DATES MOUNTAINS - ABOVE 2500 FT: FEB. 15 - MAY 15 BELOW 2500 FT: FEB. 1 - MAY 1 PIEDMONT - JAN. 1 - MAY 1 COASTAL PLAIN - DEC. 1 - APR. 15 SOIL AMENDMENTS FOLLOW RECOMMENDATIONS OF SOIL TESTS OR APPLY 2,000 LB/ACRE GROUND AGRICULTURAL LIMESTONE AND 750 LB/ACRE 10-10-10 FERTILIZER. MULCH APPLY 4,000 LB/ACRE STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING, OR A MULCH ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. MAINTENANCE RE -FERTILIZE IF GROWTH IS NOT FULLY ADEQUATE. RESEED, RE -FERTILIZE AND MULCH IMMEDIATELY FOLLOWING EROSION OR OTHER DAMAGE. TABLE 6.10B TEMPORARY SEEDING RECOMMENDATIONS FOR SUMMER SEEDING MIXTURE SPECIES RATE (LB/ACRE) GERMAN MILLET 40 IN THE PIEDMONT AND MOUNTAINS, A SMALL -STEMMED SUDAN GRASS MAY BE SUBSTITUTED AT A RATE OF 50 LB/ACRE. SEEDING DATES MOUNTAINS - MAY 15 - AUG.15 PIEDMONT - MAY 1 - AUG.15 COASTAL PLAIN - APR. 15 - AUG. 15 SOIL AMENDMENTS FOLLOW RECOMMENDATIONS OF SOIL TESTS OR APPLY 2,000 LB/ACRE GROUND AGRICULTURAL LIMESTONE AND 750 LB/ACRE 10-10-10 FERTILIZER. MULCH APPLY 4,000 LB/ACRE STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING, OR A MULCH ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. MAINTENANCE RE -FERTILIZE IF GROWTH IS NOT FULLY ADEQUATE. RESEED, RE -FERTILIZE AND MULCH IMMEDIATELY FOLLOWING EROSION OR OTHER DAMAGE. TABLE 6.10C TEMPORARY SEEDING RECOMMENDATIONS FOR FALL .4 9k 6 // g ►� PIR m1Ue_ � Ue_ � O O CC � w CV w N z4t —�, w z0- w U z _I , Q = IL U 00 � CC. .J CL = CL SEEDING MIXTURE SPECIES RATE (LB/ACRE) Z JO Z RYE (GRAIN) 120 W p[ w � Z � SEEDING DATES O O O O MOUNTAINS - AUG. 15 - DEC 15 U Z U U COASTAL PLAIN AND PIEDMONT - AUG. 15- DEC. 30 0 0 ZO 0 SOIL AMENDMENTS ~ U) oc o O oc FOLLOW SOIL TESTS OR APPLY 2.000 LB/ACRE GROUND AGRICULTURAL LIMESTONE AND w w w oC w 1.000 LB/ACRE 10-10-10 FERTILIZER. o w [r w 0- MULCH rn rn rn rn Lu APPLY 4,000 LB/ACRE STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING, OR N N C\I N A MULCH ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED 0 ao c2 co co AS A MULCH ANCHORING TOOL. , 5N o o CD CD r MAINTENANCE > REPAIR AND RE -FERTILIZE DAMAGED AREAS IMMEDIATELY. TOP -DRESS WITH 50 LB/ACRE T N OF NITROGEN IN MARCH. IF IT IS NECESSARY TO EXTEND TEMPORARY COVER BEYOND JUNE 15, OVER -SEED WITH 50 LB/ACRE KOBE (PIEDMONT AND COASTAL PLAIN) OR DATE: AUGUST29, 2018 KOREAN (MOUNTAINS) LESPEDEZA IN LATE FEBRUARY OR EARLY MARCH. HORIZONTAL SCALE: N/A VERTICAL SCALE: N/A PROJECT MANAGER: CPK STABILIZATION TIME TABLE DRAWN BY: SCS PROJECT NO: 17-002 SITE AREA DESCRIPTION STABILIZATION TIMEFRAME EXCEPTIONS DRAWING NAME: 17-002 DETAILS PERIMETER DIKES, SWALES, DITCHES 7 DAYS NONE THIS DRAWING AND THE DESIGN HEREON ARE AND SLOPES THE PROPERTY OF EarthCentric Engineering, Inc. THE INFORMATION ON THIS DRAWING IS NOT FOR USE ON ANY OTHER SITE OR PROJECT. THE HIGH QUALITY WATER (HWQ) ZONES 7 DAYS NONE REPRODUCTION OR OTHER USE OF THIS DRAWING IN WHOLE OR IN PART, WITHOUT WRITTEN CONSENT OF EarthCentric Engineering, Inc., SLOPES STEEPER THAN 3:1 7 DAYS IF SLOPES ARE 10' IN IS PROHIBITED. LENGTH AND ARE NOT COPYRIGHT2019 EarthCentric Engineering, Inc. STEEPER THAN 2:1, 14 DAYS ARE ALLOWED SLOPES 3:1 OR FLATTER 14 DAYS 7 DAYS FOR SLOPES SHEET NO. > 50' IN LENGTH ALL OTHER AREAS WITH SLOPES 14 DAYS NONE, EXCEPT FOR FLATTER THAN 4:1 PERIMETERS & HOW ZONES D 1O 4 P:\17-002\17-002 Drawings\6. Rev04\17-002 Details.dwg, D1.4 EC Details, 10/16/2019 2:24:00 PM PRELIMINARY SUBDIVISION PLAN F-AKI;tL IU#J I /UJU0, I /UJU'J, I /U,S I U, 1 5y I 1 4, 15y1 1 b, 1 5y11 / SPIDERS CARRIER PIPE STEEL ENCASEMENT PIPE NOTES: 1. NORMAL SPACING FOR SPIDERS IS 3 PER 18' LENGTH OF PIPE, ONE SUPPORT AT EACH END AND A SUPPORT AT 9' CENTER. 2. ENTIRE SPIDER ASSEMBLY TO BE BITUMINOUS COATED AFTER FABRICATION. 3. FIELD MODIFY AS REQUIRED TO PROVIDE DESIGN SLOPE IN CARRIER PIPE. 4. SIZING TABLE IN P-2.1 6" X 3/8" STEEL PLATE STEEL ENCASEMENT PIPE STAINLESS STEEL SHOES ON EACH FOOT OF SPIDER. CONTINUOUS WELD BOTH SIDE (TYP.) CARRIER PIPE C9 I Q* SEE DETAIL P-2.1 FOR SIZING OF ENCASEMENT PIPES END ELEVATION SIZING TABLE FOR CARRIER PIPES AND CASING PIPES THE FOLLOWING TABLE SUMMARIZES THE REQUIRED SIZES FOR STEEL PIPE ENCASEMENTS: NOTE: NCDOT AND THE RAILROADS MAY HAVE DIFFERENT REQUIREMENTS. STEEL PIPE ENCASEMENT NTS NOMINAL CARRIER PIPE SIZE (INCHES) STEEL CASING PIPE SIZE INCHES RAILROAD CROSSING ROAD CROSSING OUTSIDE DIAMETER WALL THICKNESS OUTSIDE DIAMETER WALL THICKNESS 3 AND UNDER 12.75 0.188 6.625 0.250 4 12.75 0.188 8.625 0.250 6 12.75 0.188 12.75 0.250 8 16 0.219 16 0.250 10 20 0.281 20 0.250 12 24 0.312 24 0.250 14 28 0.375 28 0.312 16 30 0.406 30 0.312 18 36 0.469 36 0.375 20 42 0.562 42 0.500 24 42 0.562 42 0.500 METER BOX FOR 5/8°' AND 3/4" METElRS. s,fr.rraw cxo P � 1 , J t - 1 �APPROvED By rt Iva �C10 [Y C�FiO] MM.T'1C R J I _ R 1*1-I ,,s"rlaw AA WATER SYSTEM, INC. Fn z ---I cn Z7 C D CAO 0 N f Z fTl Z � I rn z cn � o V! \ O N � f Z W fTl v 6" MIN. CLASS B CONCRETE / UNDISTURBED EARTH PLAN —BENDS UNDISTURBED EARTH \ TRENCH WIDTH 12" / CLASS B 4S. CONCRETE +� N IT: N BUTTRESS DIMENSIONS PIPE 22 1/2° BENDS 45' BENDS 90' BENDS SIZE L H L H L H 6" 1'-0" 1'-0" 1'-0" 1'-0" 1'-4" 1'-2" 8" 1'-0" 1'-0" 1'-4" 1'-2" 1'-10" 1'-6" 12" 1'-4" 1'-4" 1'-10" 1'-10" 2'-8" 2'-3" :) NOTES: 1. DIMENSION "A" SHOULD BE AS LARGE AS POSSIBLE WITHOUT INTERFERRING WITH THE MECHANICAL JOINT BOLTS 2. THE SHAPE OF THE BACK OF THE BUTTRESS MAY VARY PROVIDED THE CONCRETE IS AGAINST FIRM, UNDISTURDED EARTH. 3. BUTTRESS DIMENSIONS ARE BASED UPON A SOIL RESISTANCE OF TWO TONS PER SQ. FT. AND A WATER PRESSURE OF 150 P.S.I. NOTES: 1. DIMENSION "A" SHOULD BE AS LARGE AS POSSIBLE WITHOUT INTERFERRING WITH THE MECHANICAL JOINT BOLTS 2. THE SHAPE OF THE BACK OF THE BUTTRESS MAY VARY PROVIDED THE CONCRETE IS AGAINST FIRM, UNDISTURDED EARTH. 3. BUTTRESS DIMENSIONS ARE BASED UPON A SOIL RESISTANCE OF TWO TONS PER SQ. FT. AND A WATER PRESSURE OF 150 P.S.I. L z 1/2 L 1/2 L CLASS B < � CONCRETE UNDISTURBED UNDISTURBED EARTH N EARTH \ / y. � q TRENCH WIDTH 12" / � CLASS B � 4g• CONCRETE z p N PLAN —TEE SECTION BUTTRESS DIMENSIONS B. D. L H C D 6" 1'-3" 1'-0" � uj N O � O 8 12" 2'-3" 2'-0" iw z iw z in cn B. D. =BRANCH DIAMETER NOTES: 1. DIMENSION "C" SHOULD BE LARGE ENOUGH TO MAKE ANGLE "A" EQUAL TO OR GREATER THAN 45°. 2. DIMENSION "D" SHOULD BE AS LARGE AS POSSIBLE WITHOUT INTERFERRING WITH EHT MECHANICAL JOINTS. 3. BUTTRESS DIMENSIONS ARE BASED UPON A SOIL RESISTANCE OF TWO TONS PER SQ. FT. AND A WATER PRESSURE OF 150 P.S.I. z �7 (n 2 D o D z N N N � o � D r r � O Z N HYDRANT TEE - W/ 6" BRANCH 3,000 PSI CONCRETE BLOCKING AMERICAN DARLING OR CLOW IF VALVE BOX IS NOT IN PAVED AREA, PROVIDE A 2'-0" X 2'-0" CONCRETE COLLAR (TYP. OF ALL VALVES) 18" MIN. 2» 20" MAX. Ij- CAST IRON J VALVE BOX i 6" GATE VALVE 6" DUCTILE �� ° "�• IRON PIPE ^� 6" DUCTILE SUPPORT VALVE WITH IRON PIPE CONCRETE BLOCKING VARIES VARIES **MEGA -LUG FROM TEE THROUGH VALVE TO HYDRANT CAP RUST-OLEUM OIL BASED BRIGHT WHITE BARRELL RUST-OLEUM OIL BASED TRACTOR RED #57 WASHED STONE BY CONTRACTOR UNDISTURBED EARTH - 3,000 PSI CONCRETE BLOCKING '.•`.�X BOLTS, NUTS AND DRAIN PORTS TO BE FREE OF CONCRETE MINIMUM 6" CONCRETE PLACED UNDER BASE CMU BLOCKS MAY BE USED TO SUPPORT HYDRANT WHILE POURING BLOCKING 4Ld - Lu 00 CZ CZ NO ALTERATIONS NOR ADJUSTMENTS TO BE MADE IN THIS -' ALL WORK IN THIS AREA WITHOUT APPROVAL OF THE UTILITIES ENGINEER. AREA TO BE INSTALLED AS PER 6 4 -5 1'-8 1/2 PLUMBING CODES :z THERE IS > � VARIES IF MBX2 CAST IRON METER BOX I A W/ HOLE IN LID FOR RADIO SIDEWALK � ® READ ANTENNA F— ANGLE BALL VALVE NEPTUNE � STD. CURB WITH LOCKING WING RADIO METER CRIMP — PAVEMENT W00 ,/ � O w z _ COPPER TAIL z xQ m \ � O 0 z � O o o � vv 00000 000 0000 000000000 V Om SEE NOTE 1 BRICK °o°o°o°o° 000 o°o°o° o°o°o°o°o°o°o°o°o°o B R I C K � Z _ 3/4" TYPE "K" VERTICAL BACK FLOW PREVENTER W/ DUAL � Z n COPPER SERVICE PIPE fTl INLET CHECK VALVE ASSEM. APPROVED Cn � � 3/4" FORD METER SETTER #VBHH72— O A 4" WASHED STONE 82W-44-33G W/ COMPRESSION FITTINGS Z rr, MAIif N ONLY. NO DUEL PURPOSE NUTS. NOTE: 1) COMPRESSION FITTINGS ONLY, NO FLARED FITTINGS. 70 m COMPRESSION NUT DIRECT TAP ALLOWED ON D.I. ONLY. USE FORD DOUBLE _ < FORD 3/4" BRASS CORPORATION COCK STRAP BRASS SADDLE FOR AC AND PVC PIPES. FORD FB-1000-3Q OR APPROVED m � EQUAL. 2) 30" MIN. COVER OVER SERVICE LINES. �Jnnnn nn� � U � o .� o U 'i T � U � N � Co �,l! � N � � p � � U U c� i O ID= Cif E W � N2 0-L.LW W N w� z z� w U Z J , Q = U U Z � 0= J mIUUUU 2CL = � J � w � w � z � O O O Z C)OLLJ cooc o O oc w wwocw o wocww rn rn rn rn w o 0 0 0 N N N N 0 00 CO CO CO \ f,- f,- O O O O r Lu r N C'7 lzt DATE: AUGUST 29, 2018 HORIZONTAL SCALE: N/A VERTICAL SCALE: N/A PROJECT MANAGER: CPK DRAWN BY: SCS PROJECT NO: 17-002 DRAWING NAME: 17-002 DETAILS THIS DRAWING AND THE DESIGN HEREON ARE THE PROPERTY OF EarthCentric Engineering, Inc. THE INFORMATION ON THIS DRAWING IS NOT FOR USE ON ANY OTHER SITE OR PROJECT. THE REPRODUCTION OR OTHER USE OF THIS DRAWING IN WHOLE OR IN PART, WITHOUT WRITTEN CONSENT OF EarthCentric Engineering, Inc., IS PROHIBITED. COPYRIGHT 2019 EarthCentric Engineering, Inc.D 2 0 0 SHEET NO. :\17-002\17-002 Drawings\6. Rev04\17-002 Details.dwg, D2.0 Utility Water Details, 10/16/2019 2:24:01 PM % PRELIMINARY SUBDIVISION PLAN �Jnnnn nn� � U � o .� o U 'i T � U � N � Co �,l! � N � � p � � U U c� i O ID= Cif E W � N2 0-L.LW W N w� z z� w U Z J , Q = U U Z � 0= J mIUUUU 2CL = � J � w � w � z � O O O Z C)OLLJ cooc o O oc w wwocw o wocww rn rn rn rn w o 0 0 0 N N N N 0 00 CO CO CO \ f,- f,- O O O O r Lu r N C'7 lzt DATE: AUGUST 29, 2018 HORIZONTAL SCALE: N/A VERTICAL SCALE: N/A PROJECT MANAGER: CPK DRAWN BY: SCS PROJECT NO: 17-002 DRAWING NAME: 17-002 DETAILS THIS DRAWING AND THE DESIGN HEREON ARE THE PROPERTY OF EarthCentric Engineering, Inc. THE INFORMATION ON THIS DRAWING IS NOT FOR USE ON ANY OTHER SITE OR PROJECT. THE REPRODUCTION OR OTHER USE OF THIS DRAWING IN WHOLE OR IN PART, WITHOUT WRITTEN CONSENT OF EarthCentric Engineering, Inc., IS PROHIBITED. COPYRIGHT 2019 EarthCentric Engineering, Inc.D 2 0 0 SHEET NO. :\17-002\17-002 Drawings\6. Rev04\17-002 Details.dwg, D2.0 Utility Water Details, 10/16/2019 2:24:01 PM % PRELIMINARY SUBDIVISION PLAN W N w� z z� w U Z J , Q = U U Z � 0= J mIUUUU 2CL = � J � w � w � z � O O O Z C)OLLJ cooc o O oc w wwocw o wocww rn rn rn rn w o 0 0 0 N N N N 0 00 CO CO CO \ f,- f,- O O O O r Lu r N C'7 lzt DATE: AUGUST 29, 2018 HORIZONTAL SCALE: N/A VERTICAL SCALE: N/A PROJECT MANAGER: CPK DRAWN BY: SCS PROJECT NO: 17-002 DRAWING NAME: 17-002 DETAILS THIS DRAWING AND THE DESIGN HEREON ARE THE PROPERTY OF EarthCentric Engineering, Inc. THE INFORMATION ON THIS DRAWING IS NOT FOR USE ON ANY OTHER SITE OR PROJECT. THE REPRODUCTION OR OTHER USE OF THIS DRAWING IN WHOLE OR IN PART, WITHOUT WRITTEN CONSENT OF EarthCentric Engineering, Inc., IS PROHIBITED. COPYRIGHT 2019 EarthCentric Engineering, Inc.D 2 0 0 SHEET NO. :\17-002\17-002 Drawings\6. Rev04\17-002 Details.dwg, D2.0 Utility Water Details, 10/16/2019 2:24:01 PM % PRELIMINARY SUBDIVISION PLAN F-AKI;tL IIJ#J I /UJU0, I /UJU'J, I /U,S I U, 1 5y I 1 4, 15y1 1 b, 1 5y11 / PIPE DIAMETER WALL THICKNESS SLOPE B C D E WEIGHT 12 2 1/4 3:1 24 49 73 24 730 15 2 1/4 3:1 27 46 73 30 910 18 2 1/2 3:1 27 46 73 36 1 190 21 2 3/4 3:1 36 37 73 42 1370 24 3 3:1 42 31 1/2 73 1/2 48 1770 27 3 1/4 3:1 48 25 1/2 73 1/2 54 2130 30 3 1/2 3:1 54 19 3/4 73 3/4 60 2380 36 4 3:1 63 34 3/4 97 3/4 72 5320 42 4 1/2 3:1 63 35 98 78 5920 48 5 3:1 72 26 98 84 7470 54 5 1/2 2.4:1 66 34 100 90 8810 60 6 2:1 60 39 99 96 11180 72 7 2:1 78 21 99 108 13980 DIMENSIONS IN INCHES WEIGHT IN POUNDS FLARED END SECTION -OUTLET DIAMETER X X E D CB DIAMETER DIAMETER + 1 " SECTION X-X FLARED END SECTION -INLET DIAMETER Z Z E D CB DIAMETER DIAMETER + 1" SECTION Z-Z INLET & OUTLET FLARED END SECTIONS m v NOTES: INSTALL ALL STEPS PROTRUDING 4" FROM INSIDE FACE OF STRUCTURE WALL. z Cn < STEPS DIFFERING IN DIMENSIONS, CONFIGURATION, OR MATERIALS FROM THOSE SHOWN MAY ALSO BE USED PROVIDED THE CONTRACTOR HAS FURNISHED H Q Q F-I Z THE ENGINEER WITH DETAILS OF THE PROPOSED STEPS AND HAS RECEIVED WRITTEN APPROVAL FROM THE ENGINEER FOR THE USE OF SUCH STEPS. D,N.,p� Hp~C0U _j mz�=D =oZym Z=-Op 1H „ 00ILL ro= Lu<zo= = C9 m L~ U�OOQ n=�Z Cno _ _ n\ r CL� Z � -IL p PLAN SIDE ELEVATION PLAN SIDE ELEVATION - �6 r, NCO Ihr N ;am co or a Z v p W LL N f- 1' 1,-6,, " �. 1ai� .� CA a = CAST IRON CAST IRON z ELEVATION ELEVATION W m � m D = C p „ gry r, 1 11/4"m #6 BAR OR #8 BAR v I 1/ of GALV'D. N m> T CnUJ Z �a N p PLAN T POLYPROPYLENE ~ Z J ~ m w �B„ Y2 - SIDE PLASTIC ELEVATION PLAN SIDE ELEVATION p w a) COMPOSITE G �nl REINFORCING STEEL 12 ELEVATION #3 DEFORMED NOTE: 12 _ DO NOT USE IN STEEL ROD SECTION A -A SANITARY ELEVATION SEWER MANHOLES. SHEET 1 OF 1 SHEET 1 OF 1 $40.66 840.66 v vm H � H' Z >00p D ri Cp H z � = y GRATE AND FRAME- =C)Zym =Cn00 zH�mm BRICK 0 _ m Z MASONRY D y D WALL Cn 1 H 0 Z ANCHOR GRATE AND FRAME - CONCRETE WALL ANCHOR GRATE AND FRAME BRICK MASONRY CONCRETE CONSTRUCTION CONSTRUCTION DETAIL SHOWING ANCHORAGE OF CU FRAME FOR GRATED DROP INLET `-' z �a Z p = cn NOTE: z O = CONSTRUCT GRATED DROP :INLET TO COINCIDE WITH NORMAL v OR SUPERELEVATED SHOULDER OR PAVEMENT SLOPE. O Z m m m O v D v = ifi rr �D 3/8rr DIA. L4" 4„ 0N �8" DIA. 3/8rr _ 3/8rr O DIA. DIA. Z 10 m „ I 10" �2 mv� 1'J/ r I m MASONRY ANCHOR CONCRETE ANCHOR PRECAST 840.25 DIA. BOLT WITH PLATE % DIA. BENT BAR CONCRETE ANCHOR DIA. BENT BAR THREADED ANCHOR -1 " DIA. -APPROVED EPDXY PRECAST CONCRETE WALL PRECAST CONCRETE CONSTRUCTION PRECAST CONCRETE CONSTRUCTION CONCRETE CONSTRUCTION BRICK MASONRY CONSTRUCTION FRAME AND GRATE INSTALLATION FOR NORMAL CROWN AND SUPERELEVATED SECTIONS Z Ov I- Q Q HRc CCCC=0 LLJ�I-IZ OOvx °C Z H Cnl-w0J 00CoQ Z H = 1 (L Q O w x � o co� W U IZID -I U Q LL H o Q 0 O w x LL fL o W a O w I- a LU O = Cr O U JC�U Z Za0 w 1--1 _ m 840.25 v v m Z m Cn 0 0 mm0-1�0 z => =-nZDm =Cn00 m -0 -n HOOD �� � 0 Z w OZ O � Z H O CD N -mN -4 Y m Z c v vn o m v =� v H � m Z z r� m 840.14 v vm H-I ' Z 7C1Npp Dr o �1_ Cn m1­42E =� =-nnym =Cnxoo 2E -0 _n o O 0 = � Z DDD 0) r 0 Z w m z r W � j Cn N N = C7 Cn D = Z 7D v v Gaon oO x v _v N w " Z D -0 F. m M � -n O 840.15 v vm H' Z m Cn 0 r- o -n Cn m Z = -I =o>>m =cnoo zl..-Iomm �DDD Cn H , 0 _ Z w m O x m O m � Z � 0 = Z fn � r x v C/) v mz D (1)v 0 m v 4 a D 0Z* LL v N z O Z a p v � x Go 0 N 1 ^." WEEP HOLES I Y ' PLAN WITH GRATE 8 FRAME REMOVED I I SEE NOTE N L BRICK COPING(INCIDENTAL) TOP ELEVATION - STD. 840.16 FRAME - 8 GRATE A DOWEL(SEE NOTE) SECTION X-X V 6" GENERAL NOTES: USE CLASS "B" CONCRETE THROUGHOUT. PROVIDE ALL DROP INLETS OVER 3'-6" IN DEPTH WITH STEPS 12" ON CENTER. USE STEPS WHICH COMPLY WITH STD. DRAWING 840.66. OPTIONAL CONSTRUCTION - MONOLITHIC POUR 2" KEYWAY OR #4 BAR DOWELS AT 12" CENTERS AS DIRECTED BY THE ENGINEER. USE FORMS FOR THE CONSTRUCTION OF THE BOTTOM SLAB. IF REINFORCED CONCRETE PIPE IS SET IN BOTTOM SLAB OF BOX, ADD TO SLAB AS SHOWN ON STD. NO. 840.00. CONSTRUCT WITH PIPE CROWNS MATCHING. SEE STANDARD DRAWING 840.25 FOR ATTACHMENT OF FRAMES AND GRATES NOT SHOWN. INSTALL 2" WEEPHOLES AS DIRECTED BY THE ENGINEER. INSTALL STONE DRAINS, OF A MINIMUM OF 1 CUBIC FOOT OF NO. 7BM STONE IN A POROUS FABRIC BAG OR WRAP, AT EACH WEEP HOLE OR AS DIRECTED BY THE ENGINEER. CHAMFER ALL EXPOSED CORNERS 1". DRAWING NOT TO SCALE. a #4 BAR B 6" Cm 6,r 1 DOWEL MAX. PIPE THIS SIDE - 18" SECTION Y-Y DIMENSIONS AND QUANTITIES FOR DROP INLET(BASED ON MIN. HEIGHT, H) DIMENSIONS OF BOX & PIPE CUBIC YARDS CONIC. IN BOX DEDUCTIONS FOR ONE PIPE PIPE SPAN WIDTH IMIN. HEIGHT D A B H BOTTOM SLAB WALL PER FT. HT. TOTAL CONCRETE FOR MINIMUM HEIGHT, H C.M. R.C. 12" 3'-0" 2'-0" 2'-0" 0.222 0.222 0.592 0.015 0.026 15" 2'-3" 0.648 0.023 0.036 18" 2'-6" 0.703 0.033 0.049 24" 3'-0" 0.814 0.059 0.085 :3 3'-0" 2'-0" 3'-6" 0.222 0.222 10.825 0.092 0.127 I Y PLAN WITH COPING REMOVED SECTION X-X GENERAL NOTES: MORTAR JOINTS It" +/- Lg" THICK. USE CLASS "B" CONCRETE THROUGHOUT. USE FORMS FOR CONSTRUCTION OF THE BOTTOM SLAB. USE #4 BAR DOWELS AT 12" CENTERS. X DEDUCT FOR PIPE(S) FROM TOTAL CU. YDS. OF BRICK MASONRY. - -� PROVIDE ALL CATCH BASINS OVER 3'-6" IN DEPTH WITH STEPS 12" ON CENTER. USE STEPS WHICH COMPLY WITH STD. DRAWING 840.66. USE BRICK OR CONCRETE BLOCK WHICH COMPLIES WITH THE REQUIREMENTS OF SECTION 840 OF THE STANDARD SPECIFICATIONS. IF REINFORCED CONCRETE PIPE IS SET IN BOTTOM SLAB OF BOX, ADD TO SLAB AS SHOWN ON STD. NO. 840.00. FOR 8'-0" IN HEIGHT OR LESS, USE 8" WALL. OVER 8'-0" IN HEIGHT, USE 12" WALL TO 6'-0" FROM TOP OF WALL AND 8" WALL FOR THE REMAINING 6'-0". QUANTITES TO BE ADJUSTED ACCORDINGLY. CONSTRUCT WITH PIPE CROWNS MATCHING. SEE STANDARD DRAWING 840.25 FOR ATTACHMENT OF FRAMES AND GRATES. DO NOT USE BRICK MASONRY DROP INLET IN LOCATIONS SUBJECT TO TRAFFIC. CHAMFER ALL EXPOSED CORNERS 1". DRAWING NOT TO SCALE. uur•1Nu tiNUIUtNIAL) rOP ELEVATION STD. 840.16 RAME AND GRATE v B" B 8" 0 I TE MAX. PIPE THIS SIDE - 1 SECTION Y-Y DIMENSIONS AND QUANTITIES FOR DROP INLET(BASED ON MIN. HEIGHT, H) DIMENSIONS OF BOX & PIPE CUBIC YARDS CONCRETE CUBIC YARDS BRICK MASONRY DEDUCTIONS FOR ONE PIPE PIPE SPAN WIDTH MIN. HEIGHT D A B H BOTTOM SLAB WALL PER FOOT HT. TOTAL BRICK MASONRY FOR MIN. HEIGHT, H C.S. R.C. 12" 3'-0" 2'-0" 2'-0" 0.268 0.313 0.522 0.020 0.032 15" 2'-3" 1 0.268 0.313 0.600 0.031 0.047 18" 2'-6" 1 0.268 0.313 0.678 0.044 0.065 24" 1 3'-0" 1 0.268 0,313 0.835 0.078 0.113 30" 1 3' 0" 2'-0" 3'-6" 1 0.268 1 0.313 1 0.991 0.122 1 0.170 " ESSION SECTION G-G 2'-31/4" 1 %6" 2" SECTION H-H �11/2 rr c 1 %2'- Mr\ 15/8,r r5/8rr _G G 0 0 � - O �o 'N IL► H �\ 41/2 T V-7-5/8" 1'-75/gr' PLAN OF GRATING CAST IRON T #4 BAR N L 6" 3'-611 F-� E E N�------i---- - I I I I PLAN OF FRAME CAST IRON Y8 n 1/8" 1/8 rr 1/8rr 1 rr 1 rr 1 rr 1 rr 3'-3-3/4" 2'-33Z4" 118 n 1/8rr 1/8" 1/8 rr " 3/rr I - In 3/n 3'-2" 21_21 1 I� 21/8"21/8r, 3'-13/4'r N N 2r-13/4" N N 3'-6" 2'-6" SECTION E-E SECTION F-F z oU) H Q Q 1-4 S CD LL J a- -IZ 0Ovx wQQILL x QU�OFO-I H CnH -0 J opc~nQ 1 CL Q [� 0 W o J a Z w F-I (L a- CC a 0 O o=cr) �o o � H cn W _ N U) 0 14Z J O CD 0 w 840.14 Z 0 Cn F_ QQ Hp~C0U ILL JrLI-IZ OOC15x °C Z w LL Q U cc O o H U) LL 0 J OOUQ Z Hi = 1 ~ CL Q O 1� 840.15 z ov H>_ QQ G4 r-, LLJE"m o0cox x z aoCD Cnl-U_o OOCoa Z ,; a: 1 (H 00 Ln T N Lu ao H o z C3 Q CD � N 0 Q Q o _ co O co o W N fs 0 QLLLLo H 0 v W x J O N Z x J m H I --I z a 'S w 0 � O � fY O LL ■ U O U U 'i Q) 0 W T Cz Co M N -),l! V CItt I--. N CU � Comzt O O N Lo Co C) a� a� Y U 00 C0 > _ z T T N a) U 3: Cz CZU i c mzt O X O CU CZ W _j N�0-LLW Illllill/lll/lj/7 w cm J0� ; ^w x Z �Z•CL=wZ Q••y Q •W•;�= J r Oct • � c U d mIUUUU z JO z 2 0[-2 z O O OU z U 0U z O z U) c o O c W W W 1�1' W o D-cwD- w o000 QN N N N o 0 0 o r > � r N Co � DATE: AUGUST 29, 2018 HORIZONTAL SCALE: N/A VERTICAL SCALE: N/A PROJECT MANAGER: CPK DRAWN BY: SCS PROJECT NO: 17-002 DRAWING NAME: 17-002 DETAILS THIS DRAWING AND THE DESIGN HEREON ARE THE PROPERTY OF Earth Centric Engineering, Inc. THE INFORMATION ON THIS DRAWING IS NOT FOR USE ON ANY OTHER SITE OR PROJECT. THE REPRODUCTION OR OTHER USE OF THIS DRAWING IN WHOLE OR IN PART, WITHOUT WRITTEN CONSENT OF Earth Centric Engineering, Inc., IS PROHIBITED. COPYRIGHT 2019 Earth Centric Engineering, Inc. SHEET NO. D 0 :):\17-002\17-002 Drawings\6. Rev04\17-002 Details.dwg, D3.0 SD Details, 10/16/2019 2:24:05 PM SHEET 1 OF 1 840.16 SHEET 1 OF 1 840.16 PRELIMINARY SUBDIVISION PLAN FAKI;tL IIJ#J I /UJU0, I /UJU'J, I /U,S I U, 1 5y I 1 4, 15y1 1 b, 1 5y11 / 12" VAN 6" ACCESSIBLE -ADD THIS SIGN ONLY AT 12" DESIGNATED "VAN" SPACES RESERVED SIGNAGE PANEL PARKING (SEE OPTIONS TO THE RIGHT) 18" CENTER R7-8C HANDICAP SIGN SIGNAGE AT HEAD OF EACH R7-5c SPACE 12' SIGN SIGN THIS PANEL FOR MAXIMUM HANDICAP SIGNS ONLY PENALTY 9" 1-1/4"X 1-1/4" -$250 ALUMINUM TUBE ALUMINUM SIGN PANEL (TYP.) STEEL TROWEL FINISH FINISHED GRADE ALL STEEL FASTENERS SHALL BE GALVANIZED 8" DIA. PARKING SIGNAGE DETAILS NTS VAR. 6.0' 8.0' 5.0' PAVEMENT SHOULDER WIDTH WIDTH +2" /FT +1" /FT. 1 4" /FT. -1/4" /FT. —1" /FT. —2 1 /4" /FT. 5.0' -3" /FT. DRIVEWAY TURNOUT GRADES SHOULDER SECTION +3" /FT. El N S TRAIL Q CONCRETE PAD FOR HANDICAP PARKING & ISLE 2% MAXIMUM SURFACE SLOPE IN ANY DIRECTION ACROSS CONCRETE SECTION No, 7\ F g�0 'o. f� PREP P PRIG S> f� TYPICAL 4" WIDE AINTED LINES (WHITE) g0 � F \0 A 9� a � . d g0 g0 HANDICAP VAN 8� ACCESSIBLE SIGN TRAIL PARKING DETAIL 1" = 109 .R /* i i 16 BOX CLUSTER MAILBOX / UNIT, FACED TO CUL—DE—SAC TYPICAL SIZE SHOWN / (18" DEEP X 30.5" WIDE) / . Q / 7�0 EoP / p Cp o�'G (51 102.5" X 126" CONCRETE PAD, 8" THICK �pQ * TERRAIN MAX SLOPE LEVEL 2:1 ROLLING 2:1 HILLY 1-1/2:1 CLUSTER MAIL BOX UNITS 1" = 5' ** MODIFICATIONS REQUIRED TO SATISFY FIRE MARSHAL COMMENTS 63, R 'p I � 12.0' 26' 50' R/W 48' SLOPE AS REQUIRED SECTION AA FIGURE 8 (MODIFIED") SYMMETRICAL CUL—DE—SAC NO CURB & GUTTER TRAIL DESIGN AND CONSTRUCTION BY ALAMANCE PARKS, TRAILS & OPEN SPACE COORDINATOR 6' 1 5' , 4' S�OQ� ** MODIFICATIONS REQUIRED TO SATISFY FIRE MARSHAL COMMENTS I 50' ROW 6' 26' 6' 5' SHLDR PAVEMENT SHLDR DITC 0.08 0.02 I 0.02 0.08 3:1 RESIDENTIAL LOCAL ROAD TYPICAL SHOULDER SECTION (MODIFIED**) NTS 2.00" SF9.5A OR S9.5B * MAX SLOPE: LEVEL = 2:1 ROLLING = 2:1 MOUNTAINOUS = 1.5:1 � :1 STBC OR ABC 8" ABC OR STBC, TYPE B 3" COMPACTED SUBGRADE - 100% CTAKinAPr1 PPnrTnP PAVEMENT SECTION NTS R/W R/W I 50> /W I I 70.0' � I � R3).0' 26' RAVE. R3 .0' SIGHT TRIANGLE _ O �(TYP.) R/W_ 15" DRIVE PIPE EDGE OF PAVEMENT EDGE OF PAVEMENT EDGE OF PAVEMENT EXISTING ROAD EDGE OF PAVEMENT ** NOTE: DRAINAGE EASEMENTS MAY BE REQUIRED TO ACCOMODATE DRAINAGE BEYOND THE RIGHT—OF—WAY. WINDING CREEK TRAIL CONNECTION NTS ACCESS EASEMEN I � I I I I I 12' I PAVED APRON (SEE DETAIL BELOW) I o w I ILf) I SIGHT TRIANGLE 70.0' _ (10 X70' TYP.) IN. R/W _ _ — � — 0 20' M— —_ R/W �15" DRIVE PIPE EDGE OF PAVEMENT R20.0' R20.0' EDGE OF PAVEMENT EXISTING ROAD EDGE OF PAVEMENT EDGE OF PAVEMENT NOTE: PERMANENT DRAINAGE EASEMENTS MAY BE REQUIRED TO ACCOMODATE DRAINAGE BEYOND THE RIGHT—OF—WAY. 2'•C _ 6' SHLDR 8% 2" SF 9. VAR. - 20' 6' 5' �LDR DITC 8% 3:1 \-8" COMPACTED AGGREGATE BASE COURSE PRIVATE DRIVEWAY CONNECTION NTS it � nnnn nn� �J p U � � O o O 'i N 0 W r 1:t i (13 U �Na)m�j a)OCo m:t C90 U � UCo Co � z T T U Cz CZ Cz U O x2 O N CZ r W c�i � R ofLLW 101: � w N w � Zw Z 0- U z Q CL = - U 00 Oe EE .J CL _ CL mIUe � Ue � Ue � U z 0 z z O O OU z U 0Fz U 01: � O 01: co 01:0 O oC w w w OC w o ILocwIL rn rn rn rn Lu o 0 CD CD QN N N C\I CO CO r r CD CD CD CD r uj r Cm Co � DATE: AUGUST 29, 2018 HORIZONTAL SCALE: N/A VERTICAL SCALE: N/A PROJECT MANAGER: CPK DRAWN BY: SCS PROJECT NO: 17-002 DRAWING NAME: 17-002 DETAILS THIS DRAWING AND THE DESIGN HEREON ARE THE PROPERTY OF EarthCentric Engineering, Inc. THE INFORMATION ON THIS DRAWING IS NOT FOR USE ON ANY OTHER SITE OR PROJECT. THE REPRODUCTION OR OTHER USE OF THIS DRAWING IN WHOLE OR IN PART, WITHOUT WRITTEN CONSENT OF EarthCentric Engineering, Inc., IS PROHIBITED. COPYRIGHT 2019 EarthCentric Engineering, Inc. SHEET NO. D400 PRELIMINARY SUBDIVISION PLAN :\17-002\17-002 Drawings\6. Rev04\17-002 Details.dwg, D4.0 Site Details, 10/16/2019 2:24:08 PM