Loading...
HomeMy WebLinkAbout20191467 Ver 1_B-5323_Final_Structure_Plans_2019102914+00 14+50 15+00 15+50 16+00 N L� wd -Gq fol� � w w � Q cn z w c-D un o z (+)Oo5968% (—)Oe3000% FILL FACE AT END BENT 1 PI STA. 12+55.00 —L— W.P. #1 —L— STA. 13+64.69 EL = 309.54' ELEV. 309021 VC = 180' 320 BEGIN FRONT SLOPE STA. 13+57-21 —L— GePe ELEV. 309e23 310 -------------- EL. 308 ± 300 (TYPo) 290 HP 12X53 STEEL PILES SPAN A 1'-6" LIMITS OF EXCAVATION (TYPo EAa END) LOW CHORD Xo ELEV. = 306.83 —ELe 308± FIX° I 1, II � UNCLASSIFIED Ll STRUCTURE EXC. (TYPo EAo END) 1'-0'/ MIN. EARTH BERM (TYPo EAo END) END BENT Noo 1 SPAN B TOP OF DRILLED PIER EL. 301.00 (TYPo) FIX. q FIX° J II II ------ --- II II ELo 289 ± I I u 3'-0" 0 DRILLED SHAFT (TYPJ BENT No. 1 SPAN C EXISTING SUBSTRUCTURE (TYPo) BASE HW (0100) FIXe -i ELEV o30307' NORMAL POOL F EI> ELEV. 30000' --ram I I I I I I I I ------------ LJ� LJ EL. 286 ± BENT No. 2 BEGIN SHORING /^ T r\ T T r\ A 1 A 1 /\ A 1 r\ 1 PLAN (PILES NOT SHOWN FOR CLARITY°) i BENT No. 3 SPAN D 1'-7" MIN. BERM _ LOW CHORD (TYPo EA. END) ELEV. = 306.23 1.5e1 SLOPE NORMAL TO CAP (TYPo) FIX. ELe 308±� -- -- EL. 303 ± I I I o I BENCH ELEV. 293.00 u (TYPo) FILL FACE AT END BENT 2 W.P. 45 —L— STA. 15+67.31 ELEV. 308.60 BEGIN FRONT SLOPE STA. 15+74.70 —1— G.P. ELEV. 308.57 +11 o395� (—)Oe3000% O PI STA.16+85.00 —L— EL = 308.24' VC = 200' — — — — — — — — 7APPROX.NATURAL ----- �7-- EL. 308± GROUND LINE HP 12X53 STEEL PILES CLASS II RIP RAP W/GEOTEXTILE (TYPo EAo END) END BENT Noo 2 DOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED ;OUNTY L- GE 380143 c� N Lo .. -04 -64 � w w � a V) z w >- 0 0 V) o D f* fol� fol� HP 12X53 STEEL PILES�� i STA.14+10.88 -L- W.P. #2 END BENT 1 FOUNDATION NOTES 1e FOR PILES,SEE SECTION 450 OF THE STANDARD SPECIFICATIONS° BENT #1 CONTROL j LINE & C 3'-0"0 DRILLED PIERS i i i i i ` I / I I o I � i I I I I I I I I BENT 1 20 PILES AT END BENT NO.1 ARE DESIGNED FOR A FACTORED RESISTANCE OF 65 TONS PER PILE. 3. DRIVE PILES AT END BENT NOo1 TO A REQUIRED DRIVING RESISTANCE OF 110 TONS PER PILE. 4. PILES AT END BENT NOo2 ARE DESIGNED FOR A FACTORED RESISTANCE OF 75 TONS PER PILE. 5. DRIVE PILES AT END BENT NO.2 TO A REQUIRED DRIVING RESISTANCE OF 125 TONS PER PILE. 0 d- STA.14+56.00 -L- W.P. #3 BENT #2 CONTROL j LINE & C 3'-0"0 DRILLED PIERS i i i i i � I / I I o BRIDGE I.D. STA. 14+66.00 -L- i 90 ° 00'00" (TYP.) o BENT 2 FOUNDATION LAYOUT ALL BENTS ARE PARALLEL STA. 15+11.13 -L- W.P. #4 BENT #3 CONTROL j LINE & C 3'-0"0 DRILLED PIERS i i i i i � I / I I o i I I I I I I I I BENT 3 v LL L: Q a z. HP 12X53 j STEEL PILES END BENT 2 HYDRAULIC DATA DESIGN DISCHARGE 5100 CFS FREQUENCY OF DESIGN FLOOD 25 YR. DESIGN HIGHWATER ELEV. 300.1 FT. DRAINAGE AREA 36.4 SO. MI. BASE DISCHARGE (0100) 7106 CFS BASE HIGHWATER ELEV. 303.7 FT * FEMA OVERTOPPING FLOOD DATA OVERTOPPING DISCHARGE 28572 CFS FREQUENCY OF OVERTOPPING FLOOD 500+ YR. OVERTOPPING FLOOD ELEV. 308.5 FT. 6. FOR DRILLED PIERS,SEE SECTION 411 OF THE STANDARD SPECIFICATIONS° SAG LOCATED AT STA. 16+20000 -L- 7o DRILLED PIERS AT BENT NO. 1,BENT NO.2 AND BENT NO.3 ARE DESIGNED FOR A FACTORED RESISTANCE OF 395 TONS PER PIER. CHECK FIELD CONDITIONS FOR THE REQUIRED TIP RESISTANCE OF 130 TSF. 8. PERMANENT STEEL CASINGS ARE REQUIRED FOR DRILLED PIERS AT BENT NO. 1.DO NOT EXTEND PERMANENT CASINGS BELOW ELEVATION 278 FT WITHOUT PRIOR APPROVAL FROM THE ENGINEER. 9. INSTALL PERMANENT STEEL CASINGS AT BENT NOo1 BY VIBRATING, SCREWING OR DRIVING PERMANENT CASINGS BEFORE EXCAVATING OR DISTURBING ANY MATERIAL BELOW ELEVATION 279 FT. 10. PERMANENT STEEL CASINGS ARE REQUIRED FOR DRILLED PIERS AT BENT NO. 2.DO NOT EXTEND PERMANENT CASINGS BELOW ELEVATION 275 FT WITHOUT PRIOR APPROVAL FROM THE ENGINEER° 11. INSTALL PERMANENT STEEL CASINGS AT BENT NO.2 BY VIBRATING, SCREWING OR DRIVING PERMANENT CASINGS BEFORE EXCAVATING OR DISTURBING ANY MATERIAL BELOW ELEVATION 276 FT. 12. PERMANENT STEEL CASINGS ARE REQUIRED FOR DRILLED PIERS AT BENT NO. J.DO NOT EXTEND PERMANENT CASINGS BELOW ELEVATION 278 FT WITHOUT PRIOR APPROVAL FROM THE ENGINEER. 13o INSTALL PERMANENT STEEL CASINGS AT BENT NO. 3 BY VIBRATING, SCREWING OR DRIVING PERMANENT CASINGS BEFORE EXCAVATING OR DISTURBING ANY MATERIAL BELOW ELEVATION 279 FT. PROJECT NOo B-5323 14. INSTALL DRILLED PIERS AT BENT NO.1 TO A TIP ELEVATION NO HIGHER THAN 273 FT WITH THE REQUIRED TIP RESISTANCE. GRANVILLE COUNTY 15. INSTALL DRILLED PIERS AT BENT NO.2 TO A TIP ELEVATION NO HIGHER THAN 269 FT WITH THE REQUIRED TIP RESISTANCE. 16e INSTALL DRILLED PIERS AT BENT NO.3 TO A TIP ELEVATION NO HIGHER THAN 273 FT WITH THE REQUIRED TIP RESISTANCE° STATION: 14+66o00 -L- 17. THE SCOUR CRITICAL ELEVATION FOR BENT NOe1 IS ELEVATION 279 FT. SCOUR CRITICAL ELEVATIONS ARE USED TO MONITOR POSSIBLE SCOUR PROBLEMS DURING THE LIFE OF THE STRUCTURE. 0 SHEET 2 OF 3 18. THE SCOUR CRITICAL ELEVATION FOR BENT NO.2 IS ELEVATION 276 FT. SCOUR CRITICAL ELEVATIONS ARE USED TO MONITOR POSSIBLE SCOUR PROBLEMS DURING THE LIFE OF THE STRUCTURE. 19. THE SCOUR CRITICAL ELEVATION FOR BENT NO.3 IS ELEVATION 277 FT. SCOUR CRITICAL ELEVATIONS ARE USED TO MONITOR POSSIBLE SCOUR PROBLEMS DURING THE LIFE OF THE STRUCTURE. 20. SID INSPECTIONS MAY BE REQUIRED FOR DRILLED PIERS. THE ENGINEER WILL DETERMINE THE NEED FOR SID INSPECTIONS. FOR SID INSPECTIONS, SEE SECTION 411 OF THE STANDARD SPECIFICATIONS° 21. DO NOT USE SLURRY CONSTRUCTION FOR DRILLED PIERS AT BENT NO. 1, BENT NO. 2 AND BENT NO. 3. DOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED TBM #2: RAILROAD SPIKE SET IN 16' OAK TREE 1056.71 FT FROM -BL- STA. 5+00.00, ELEV. 308.71 CV Lo .. -04 -64 � w w � a V) z w >_ 0 0 V)oD f* fol� fol� CLASS IT - RIP RAP (TYP. EAo END) TEMPORARY SHORING (TYPo) BRIDGE I.D. STA. 14+66.00 -L- - EXISTING SUBSTRUCTURE (TYPo) _. \PP MEN •• TO SR 1431Nil •• •,• .• • RD Ell ••'•• •• IN lal _ q _ l A1�MUM I =11F PROPOSED GUARDRAIL (ROADWAY PAY ITEM AND DETAIL) (TYPo AS SHOWN) LOCATION SKETCH ___/ 1 3 DRAIN PIPE W/ ELBOWS (ROADWAY PAY ITEM AND DETAIL) (TYPo AS SHOWN) 16+00 ROCK PLATING (ROADWAY PAY ITEM) TO VIRGINIA FOR UTILITY INFORMATION,SEE UTILITY PLANS AND SPECIAL PROVISIONS° GENERAL NOTES: 1. ASSUMED LIVE LOAD = HL-93 OR ALTERNATE LOADING 2. THIS BRIDGE HAS BEEN DESIGNED IN ACCORDANCE WITH THE AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS 3. THIS BRIDGE IS LOCATED IN SEISMIC ZONE 1 4. THIS STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE WITH "HEC 18 - EVALUATING SCOUR AT BRIDGES." 5. THE SUBSTRUCTURE OF THE EXISTING BRIDGE INDICATED ON THE PLANS IS FROM THE BEST INFORMATION AVAILABLE° SINCE THIS INFORMATION IS SHOWN FOR THE CONVENIENCE OF THE CONTRACTOR, THE CONTRACTOR SHALL HAVE NO CLAIM WHATSOEVER AGAINST THE DEPARTMENT OF TRANSPORTATION FOR ANY DELAYS OR ADDITIONAL COST INCURRED BASED ON DIFFERENCE BETWEEN THE EXISTING BRIDGE SUBSTRUCTURE SHOWN ON THE PLANS AND THE ACTUAL CONDITIONS AT THE PROJECT SITE. 6. REMOVAL OF THE EXISTING BRIDGE SHALL BE PERFORMED SO AS NOT TO ALLOW DEBRIS TO FALL INTO THE WATER. THE CONTRACTOR SHALL REMOVE THE BRIDGE AND SUBMIT PLANS FOR DEMOLITION IN ACCORDANCE WITH ARTICLE 402-2 OF THE STANDARD SPECIFICATIONS° 7. FOR OTHER DESIGN DATA AND GENERAL NOTES, SEE SHEET SN. 8. FOR SUBMITTAL OF WORKING DRAWINGS, SEE SPECIAL PROVISIONS. 9. FOR FALSEWORK AND FORMWORK, SEE SPECIAL PROVISIONS° 10. FOR CRANE SAFETY,SEE SPECIAL PROVISIONS° 11. FOR GROUT FOR STRUCTURES, SEE SPECIAL PROVISIONS° 12. FOR EROSION CONTROL MEASURES,SEE EROSION CONTROL PLANS. 13. ASPHALT WEARING SURFACE IS INCLUDED IN ROADWAY QUANTITY ON ROADWAY PLANS. 14. THE EXISTING STRUCTURE #380143 CONSISTING OF FOUR (4) TIMBER SPANS Cad 35-4 45'-0 35-0 AND 45'-6" (160'-10" TOTAL LENGTH), 19'-0" CLEAR ROADWAY WIDTH AND TIMBER DECK WITH AN ASPHALT WEARING SURFACE ON TIMBER END BENTS AND BENT 1 WITH TIMBER PILES AND BENT 2 & BENT 3 WITH CONCRETE PIERS NEAR THE WATER LINE AND LOCATED AT THE PROPOSED STRUCTURE SHALL BE REMOVED IN THEIR ENTIRETY. EXISTING INTERIOR BENTS SHALL BE REMOVED TO ONE FOOT BELOW THE MUD LINE. THE EXISTING BRIDGE IS PRESENTLY POSTED FOR A LOAD LIMIT OF 12 TONS FOR SINGLE VEHICLES AND 16 TONS FOR TRACTOR TRAILERS. SHOULD THE STRUCTURAL INTEGRITY OF THE BRIDGE DETERIORATE DURING CONSTRUCTION OF THE PROPOSED BRIDGE,A LOAD LIMIT MAY BE POSTED AND MAY BE REDUCED AS FOUND NECESSARY DURING THE LIFE OF THE PROJECT. TOTAL BILE OF MATERIAL REMOVAL OF EXISTING STRUCTURE ASBESTOS ASSESSMENT 3'-0" DIA. DRILLED PIERS NOT IN SOIL 3'-0" DI A. DRILLED PIERS IN SOIL PERMANENT STEEL CASING FOR 3'-0"0 DRILLED PIER SID TESTING CSL TESTING UNCLASSIFIED STRUCTURE EXCAVATION CLASS A CONCRETE BRIDGE APPROACH SLABS REINFORCING STEEL SPIRAL COLUMN REINFORCING STEEL PILE DRIVING EQUIPMENT SETUP FOR HP 12X53 STEEL PILES HP 12X53 STEEL PILES 2-BAR METAL RAIL RIP RAP CLASS II (2,_0„ THICK) GEOTEXTILE FOR DRAINAGE ELASTOMERIC BEARINGS 3'-0"x 1'-9" PRESTRESSED CORED SLABS TEMPORARY SHORING LUMP SUM LUMP SUM LIN. FTo LIN. FT. LIN. FTo EACH EACH LUMP SUM CY LUMP SUM LBS LBS EACH No. LF LF TON SY LUMP SUM No. LF SF SUPERSTRUCTURE LUMP SUM 385.75 LUMP SUM 48 2400.00 END BENT No.1 LUMP SUM 22.8 2,806 7 7 175 440 485 3580 BENT No.1 45.0 46.8 23.0 1 1 15.6 9,075 1,568 BENT Noo 2 45.0 58.4 26.0 1 1 15.5 9,699 1,761 BENT Noo 3 15.0 69.9 23.0 1 1 15.4 8,716 1,453 END BENT Noe 2 LUMP SUM 22.8 2,806 7 7 175 400 440 3580 TOTAL LUMP SUM LUMP SUM 105.0 175.1 1 72.0 3 3 1 LUMP SUM 92.1 LUMP SUM 33,102 4,782 14 14 350 385.75 840 925 LUMP SUM 48 2400.00 7160 GENERAL NOTES (CONTINUED): 15. FOR ASBESTOS ASSESSMENT FOR BRIDGE DEMOLITION AND RENOVATION ACTIVITIES,SEE SPECIAL PROVISIONS. 16. BEST MANAGEMENT PRACTICES FOR BRIDGE DEMOLITION AND REMOVAL WILL BE IMPLEMENTED DURING THE REMOVAL OF THE EXISTING BRIDGE° 17. INASMUCH AS THE PAINT SYSTEM ON THE EXISTING STRUCTURAL STEEL CONTAINS LEAD, THE CONTRACTOR'S ATTENTION IS DIRECTED TO ARTICLE 107-1 OF THE STANDARD SPECIFICATIONS. ANY COSTS RESULTING FROM COMPLIANCE WITH APPLICABLE STATE OR FEDERAL REGULATIONS PERTAINING TO HANDLING OF MATERIALS CONTAINING LEAD BASED PAINT SHALL BE INCLUDED IN THE BID PRICE FOR 'REMOVAL OF EXISTING STRUCTURE AT STATION 14+66.00 -L-. DRAWN BY: V. CHUNG DATE 10-18 CHECKED BY: E. PHELPS DATE II-18 DESIGN ENGINEER OF RECORD: D. RUGGLES DATE 12-18 PROJECT NOo B-5323 GRANVILLE STATION: SHEET 3 OF 3 COUNTY 14+66.00 -L- STATE OF NORTH CAROLINA DEPARTMENT OF TRANSPORTATION RALEIGH DOCUMENT NOT CONSIDERED GENERAL DRAWING FINAL UNLESS ALL BRIDGE OVER JOHN Ho RESERVOIR SIGNATURES COMPLETED Firm License No. C-1051 ON SR 1442 (DAVE WINSTON RD) 223 S. west St, BETWEEN SR 1431 AND VIRGINIA Suite 1100 7oll Raleigh, NC 27603 T 919.380.8750 www.stewartinc.com REVISIONS SHEET NO. NO. BY: DATE: NO. BY: DATE: S - 3 STEWART 3STL HOEETS P. 4 11 26 LOAD FACTORS-, wig -04 -64 � w w � a � � m cn z w >_ 0 0 V) o z f* fol� fol� LOAD AND RESISTANCE FACTOR RATING (ERED) SUMMARY FOR PRESTRESSED CONCRETE GIRDERS STRENGTH I LIMIT STATE SERVICE III LIMIT STATE MOMENT SHEAR MOMENT cn z 0 z 0 z 0 cl�w 0 m z 0 o z 0 0 C� C� Z Z U X O H U Q U W Li-0 LL O H U Q U w Li- Li-U 0 0 W 0 a U m w LL 0 H H Q Q 0 Q 0 Q O z ,� v J a LL Q a cn m cn LL J LIJ O+ U z m cn LL J W O+ U z Q a 0 m cn LL J W + U z J 00:� 0 HQ:� C D Z W I -I Q:� (3 Z W O Q H 0 Z W J u _ Q Z I --I -1 0 0 z LLJ Q 0 z LL Q -1 0 � 0 z LIJ Q W > W H CD Z I- O H cn W I --I Z 0 Z H Z O Z W I --I Z 0 [-- Z > = 1.088 '-'o za z >0 cn0 Q m cnLLa cnu a m 0LLQ >0 cn0 � a � cnwa > W W Li0 O O H Q O H Q H Q Q W H H Lv W H Q Q a_H H W a_H Q H Q Q W H H W W O J > 3:U J � .__. J W O LL Q:� O LL Q__ 0 CD 0 J 0 J LL O LL Q:� O _J 0 u HL-93(Inv) N/A 1 1.088 -- 1.75 0.277 1.34 45' EL 22 0.539 1.23 45' EL 2.2 0.80 0.277 1.09 45' EL 22 HL-93(Opr) N/A -- 1.590 -- 1.35 0.277 1.74 45' EL 22 0.539 1.59 45' EL 2.2 N/A -- -- -- -- -- DESIGN LOAD HS-20(Inv) 36.000 2 1.336 48.104 1.75 0.277 1.65 45' EL 22 0.539 1.45 45' EL 2.2 0.80 0.277 1.34 45' EL 22 RATING HS-20(Opr) 36.000 -- 1.882 67.763 1.35 0.277 2.14 45' EL 22 0.539 1.88 45' EL 2.2 N/A -- -- -- -- -- SNSH 13.500 -- 2.611 35.252 1.4 0.277 4.02 45' EL 22 0.539 4.01 45' EL 2.2 0.80 0.277 2.61 45' EL 22 SNGARBS2 20.000 -- 2.108 42.166 1.4 0.277 3.25 45' EL 22 0.539 2.94 45' EL 2.2 0.80 0.277 2.11 45' EL 22 SNAGRIS2 22.000 -- 2.067 45.466 1.4 0.277 3.15 45' EL 17.6 0.539 2.77 45' EL 2.2 0.80 0.277 2.07 45' EL 22 SNCOTTS3 27.250 -- 1.304 35.527 1.4 0.277 2.01 45' EL 22 0.539 2.01 45' EL 2.2 0.80 0.277 1.30 45' EL 22 V' SNAGGRS4 34.925 -- 1.150 40.181 1.4 0.277 1.77 45' EL 22 0.539 1.74 45' EL 2.2 0.80 0.277 1.15 45' EL 22 SNSSA 35.550 -- 1.121 39.841 1.4 0.277 1.73 45' EL 22 0.539 1.79 45' EL 2.2 0.80 0.277 1.12 45' EL 22 SNS6A 39.950 -- 1.056 42.175 1.4 0.277 1.63 45' EL 22 0.539 1.67 45' EL 2.2 0.80 0.277 1.06 45' EL 22 SNS7B 42.000 3 1.006 42.268 1.4 0.277 1.55 45' EL 22 0.539 1.68 45' EL 2.2 0.80 0.277 1.01 45' EL 22 LEGAL LOAD TNAGRIT3 33.000 -- 1.296 42.759 1.4 0.277 2 45' EL 22 0.539 1.96 45' EL 2.2 0.80 0.277 1030 45' EL 22 RATING TNT4A 33.075 -- 10309 43.305 1.4 0.277 2.02 45' EL 22 0.539 1.88 45' EL 2.2 0.80 0.277 1.31 45' EL 22 TNT6A 41.600 -- 1.099 45.712 1.4 0.277 1.69 45' EL 22 0.539 1.83 45' EL 2.2 0.80 0.277 1.10 45' EL 22 TNT7A 42.000 -- 1.120 47.043 1.4 0.277 1.73 45' EL 22 0.539 1.69 45' EL 2.2 0.80 0.277 1.12 45' EL 22 TNT7B 42.000 -- 1.166 48.975 1.4 0.277 1.8 45' EL 22 0.539 1.61 45' EL 2.2 0.80 0.277 1.17 45' EL 22 TNAGRIT4 43.000 -- 1.111 47.757 1.4 0.277 1.71 45' EL 22 0.539 1.55 45' EL 2.2 0.80 0.277 1.11 45' EL 22 TNAGTSA 45.000 -- 1.033 46.505 1.4 0.277 1.59 45' EL 22 0.539 1.59 45' EL 2.2 0.80 0.277 1.03 45' EL 22 TNAGTSB 45.000 -- 1.009 45.408 1.4 0.277 1.56 45' EL 22 0.539 1.47 45' EL 2.2 0.80 0.277 1.01 45' EL 22 O O O ERFR SUMMARY FOR SPAN 'A' & 'B' DESIGN LOAD LIMIT STATE YDC YAW RATING STRENGTH I 1.25 1.50 FACTORS SERVICE III 1 1.00 1 1.00 NOTES-, MINIMUM RATING FACTORS ARE BASED ON THE STRENGTH I AND SERVICE III LIMIT STATES. ALLOWABLE STRESSES FOR SERVICE III LIMIT STATE ARE AS REQUIRED FOR DESIGN. (D CONTROLLING LOAD RATING ODESIGN LOAD RATING (HL-93) ODESIGN LOAD RATING (HS-20) OLEGAL LOAD RATING SEE CHART FOR VEHICLE TYPE GIRDER LOCATION I - INTERIOR GIRDER EL - EXTERIOR LEFT GIRDER ER - EXTERIOR RIGHT GIRDER DOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED PROJECT NO. B-5323 GRANVILLE COUNTY STATION: SHEET 1 OF 2 14+66.00 -L- STD. NO. 21LRFR1-90S-45L LOAD FACTORS-, c� N Lo wig -04 -64 � w w � a cn z w >_ 0 0 V) o z f* fol� fol� LOAD AND RESISTANCE FACTOR RATING (ERED) SUMMARY FOR PRESTRESSED CONCRETE GIRDERS STRENGTH I LIMIT STATE SERVICE III LIMIT STATE MOMENT SHEAR MOMENT z O z O z O cn cl�w O z O O z O O U C� z Z U X O -- H U Q U � Li-O LL O U Q U � LL LL O O H D 0 U a U 0 Li- LL CD H H Q Q O �� Q O Q O Z v J LL Q LL J W O+ �mD LL J LJ O+ Q LL J W O + W J I- -J Q O m CD I I Q (n OQ:� m (n "cl:� 0 c__ U z Z w m (n H m (3 m U z '�_ Z w Q cn OQ:� m V) " m 0 � U '4- Z w Z J U _ Z I --I J O m 0 Z W Q � CDZ LLJ Q J O � O Z LLJ Q W => W H 0 z W H (n W I --I Z C:) Z I --I Z 0 Z W H Z C:) Z > = H O z Q z z > v (n U Q cn w Q 0 U Q D:� cn LL_ Q > v (n U Q cn LL_ Q => W W W O O H Q m O H Q H Q Q W H H LL W H Q Q W H H W W H Q H Q Q W H H W W O J > 3 U _J _J w C� LL m 0 _J 0 L) LL 0-- (n CD O J T _J w C:) LL m (n C3 C� J 0 O HL-93(Inv) N/A 1 1.055 -- 1.75 0.275 1.23 55' EL 27 0.523 1.23 55' EL 5.4 0.80 0.275 1.05 55' EL 27 HL-93(Opr) N/A -- 1.591 -- 1.35 0.275 1.59 55' EL 27 0.523 1.59 55' EL 5.4 N/A -- -- -- -- -- DESIGN LOAD HS-20(Inv) 36.000 2 1.322 47.585 1.75 0.275 1.54 55' EL 27 0.523 1.47 55' EL 5.4 0.80 0.275 1.32 55' EL 27 RATING HS-20(Opr) 36.000 -- 1.9 68.396 1.35 0.275 1.99 55' EL 27 0.523 1.9 55' EL 5.4 N/A -- -- -- -- -- SNSH 13.500 -- 2.776 37.476 1.4 0.275 4.04 55' EL 27 0.523 4.17 55' EL 5.4 0.80 0.275 2.78 55' EL 27 SNGARBS2 20.000 -- 2.155 43.095 1.4 0.275 3.14 55' EL 27 0.523 3.02 55' EL 5.4 0.80 0.275 2.15 55' EL 27 SNAGRIS2 22.000 -- 2.079 45.734 1.4 0.275 3.03 55' EL 27 0.523 2.83 55' EL 5.4 0.80 0.275 2.08 55' EL 27 SNCOTTS3 27.250 -- 1.384 37.708 1.4 0.275 2.01 55' EL 27 0.523 2.09 55' EL 5.4 0.80 0.275 1.38 55' EL 27 U' SNAGGRS4 34.925 -- 1.189 41.527 1.4 0.275 1.73 55' EL 27 0.523 1.77 55' EL 5.4 0.80 0.275 1.19 55' EL 27 SNSSA 35.550 -- 1.16 41.255 1.4 0.275 1.69 55' EL 27 0.523 1.82 55' EL 5.4 0.80 0.275 1.16 55' EL 27 SNS6A 39.950 -- 1.079 43.102 1.4 0.275 1.57 55' EL 27 0.523 1.68 55' EL 5.4 0.80 0.275 1.08 55' EL 27 SNS7B 42.000 -- 1.028 43.175 1.4 0.275 1.5 55' EL 27 0.523 1.67 55' EL 5.4 0.80 0.275 1.03 55' EL 27 LEGAL LOAD TNAGRIT3 33.000 -- 1.32 43.556 1.4 0.275 1.92 55' EL 27 0.523 1.98 55' EL 5.4 0.80 0.275 1.32 55' EL 27 RATING TNT4A 33.075 -- 1.33 43.979 1.4 0.275 1.94 55' EL 27 0.523 1.91 55' EL 5.4 0.80 0.275 1.33 55' EL 27 TNT6A 41.600 -- 1.101 45.811 1.4 0.275 1.6 55' EL 27 0.523 1.83 55' EL 5.4 0.80 0.275 1.10 55' EL 27 TNT7A 42.000 -- 1.114 46.804 1.4 0.275 1.62 55' EL 27 0.523 1.71 55' EL 5.4 0.80 0.275 1.11 55' EL 27 TNT7B 42.000 -- 1.163 48.848 1.4 0.275 1.69 55' EL 27 0.523 1.62 55' EL 5.4 0.80 0.275 1.16 55' EL 27 TNAGRIT4 43.000 -- 1.101 47.33 1.4 0.275 1.6 55' EL 27 0.523 1.56 55' EL 5.4 0.80 0.275 1.10 55' EL 27 TNAGTSA 45.000 -- 1.031 46.405 1.4 0.275 1.5 55' EL 27 0.523 1.58 55' EL 5e4 0.80 0.275 1.03 55' EL 27 TNAGTSB 45.000 3 1.013 45.582 1.4 0.275 1.47 55' EL 27 0o523 1.48 55' EL 5.4 0.80 0.275 1.01 55' EL 27 O O O ERFR SUMMARY FOR SPAN 'C' & 'D' DESIGN LOAD LIMIT STATE Yoc YAW RATING STRENGTH I 1.25 1.50 FACTORS SERVICE III 1 1.00 1 1.00 NOTES-, MINIMUM RATING FACTORS ARE BASED ON THE STRENGTH I AND SERVICE III LIMIT STATES. ALLOWABLE STRESSES FOR SERVICE III LIMIT STATE ARE AS REQUIRED FOR DESIGN. (D CONTROLLING LOAD RATING ODESIGN LOAD RATING (HL-93) ODESIGN LOAD RATING (HS-20) OLEGAL LOAD RATING SEE CHART FOR VEHICLE TYPE GIRDER LOCATION I - INTERIOR GIRDER EL - EXTERIOR LEFT GIRDER ER - EXTERIOR RIGHT GIRDER DOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED PROJECT NO. B-5323 GRANVILLE COUNTY STATION: SHEET 2 OF 2 14+66.00 -L- STD. NO. 21LRFR1-90S-55L 36'-0" wig -04 -64 � w w � a cn z w >- 0 0 V) o D f* fol� fol� 1" m � I CV ire I � 33'-6" (CLEAR ROADWAY) 1'-2" 16'-91, 16'-9" -L- TWO BAR METAL RAIL WITH CONCRETE 7" Cagy BRGo Cl PARAPET (TYPo) FOR DETAILS SEE '2 BAR METAL RAIL SECTION" 23/q" C� BRGo 3 2/q Cad BRGo GRADE PT. ASPHALT SURFACE WEARING (SEE ROADWAY PLANS) 0o02 0o02 , 00 0000000000 0.6" 0 L.R. TRANSVERSE SHEAR KEYS TO BE FILLED WITH GROUT AFTER POST —TENSIONING STRAND ALL ERECTION HAS BEEN COMPLETED AND AFTER 3'-0" IN 2�/2"0 HOLE FINAL TENSIONING OF TRANSVERSE STRANDS 18'-0" 18'-0" 12 PRESTRESSED CONCRETE CORED SLAB UNITS = 36'-0'/ HALF SECTION AT INTERMEDIATE DIAPHRAGMS ASPHALT WEARING SURFACE HALF SECTION THROUGH VOIDS TYPICAL SECTION * -THE MAXIMUM CONCRETE PARAPET HEIGHT AND ASPHALT THICKNESS IS SHOWN. THE HEIGHT OF THE CONCRETE PARAPET AND ASPHALT THICKNESS VARIES WHILE THE TOP OF THE CONCRETE PARAPET FOLLOWS THE PROFILE OF THE GUTTERLINEo FOR RAIL HEIGHT DETAILS AND ASPHALT THICKNESS SEE THE "PARAPET SECTION" DETAIL° FIXED END 211211 0 DOWEL HOLE 12" 0 i 6" VOIDS 112 C-- - - - - -- SEE "BRIDGE rn APPROACH SLAB" SHEET F 0 R DETAILS \ '�---- -- -------� Qo 2 LAYERS OF 30 LB. i CY) ROOFING FELT TO PREVENT BOND. ELASTOMERIC 111211 0 BACKER ROD ,------ _; BEARING PAD BEARING SEE "END BENT" & #6 DOWELS SHEETS FOR DETAILS SECTION AT END BENT HOLE FOR TRANSVERSE STRAND ------ ---------- I I I I I � I I I o - ----J L---- -- 4" 8„ ELEVATION VIEW C 0e6" 0 L.R. TRANSVERSE POST -TENSIONING STRAND SHEATHED WITH A NON -CORROSIVE PIPEo A 7 X 5" X 5" 0 00 oDo STRAND VISE oD o04 o 0 o D ooD°o opo° odo° OUTSIDE FACE LiFILL RECESS OF EXTERIOR i/4„ 5i/4„� i/q„WITH GROUT CORED SLAB SECTION B-B GROUTED RECESS AT END OF POST —TENSIONED STRAND OF CORED SLABS ASPHALT WEARING SURFACE FIXED END FIXED END C JTe 1 /2" JTo AT BENT (-21/21'0 DOWEL HOLES ELASTOMERIC BEARING PAD i 21'0 BACKER ROD ELASTOMERIC CL BEARING '�, �--'--� � , ____ _i BEARING PAD & #6 DOWELS SEE BENT SHEETS FOR DETAILS SECTION AT BENT 8 I/2 „ 9 i/2 „ 9 i/2 „ 8 1/2 1'-2" 4" 4" 1'-2" 3" F-FT \N N #5 S1 .I 1. ° � •I I I I� #5 S1 N� #5 S1 1" 3'-0" 1'-6" 1'-6" 10" 10" Doi pol-a 3" 11" 4" 4" 11" 3" #4 „B„—L-1 ~� 12" 0 VOIDS N �CONSTo JTo o (TYPo) I C7) \N •' o #4 S2 ♦® ®�o c�. N N , 3 7 7 3 j -OI­----w- 1 1 2 SPA. IE74 SPA. 2 SPA. 2 2" CTSo @ 2" CTSo Cagy 2" CTSo INTERIOR SLAB SECTION (45' UNIT) (13 STRANDS REQUIRED) 3%" CLo 3'-0" 10" 1'-4" 10" #5 S3 #4 „B„ 3" 3„ N � o �I o #4 S2 12" 0 VOIDS N 3" 3" EXT. SLAB SECTION (FOR PRESTRESSED STRAND LAYOUT,SEE INTERIOR SLAB SECTION.) A BOND SHALL BE BROKEN ON THESE STRANDS FOR A DISTANCE OF 6'-0"FROM END OF CORED SLAB UNIT. SEE STANDARD SPECIFICATIONS, ARTICLE 1078-7. 1'-6" 1'-6" ❑® BOND SHALL BE BROKEN ON THESE STRANDS FOR A DISTANCE OF 2'-0"FROM END OF CORED SLAB UNIT. 10" 1'-4" 10, SEE STANDARD SPECIFICATIONS, ARTICLE 1078-7. 3" O OPTIONAL FULL LENGTH DEBONDED STRANDS. #4 „B„ THESE STRANDS ARE NOT REQUIRED° IF THE 12" 6 VOIDS FABRICATOR CHOOSES TO INCLUDE THESE STRANDS N IN THE CORED SLAB UNIT, THE STRANDS SHALL BE DEBONDED FOR THE FULL LENGTH OF THE UNIT o'°.o :° °: °+ + ♦ AT NO ADDITIONAL COST. SEE STANDARD SPECIFICATIONS, ARTICLE 1078-7. o I - � N I #4 DEBONDING LEGEND o S2 ♦ ♦ ®� ® ,:.fie} .`: ............................... . . . 3 7 7 3 2 SPA. 4 SPA. 2 SPA. C� 2" CTSo Cad 2" CTSo @ 2" CTSo INTERIOR SLAB SECTION (55' UNIT) (19 STRANDS REQUIRED) Oo6" 0 LOW RELAXATION STRAND LAYOUT 3/$ „ 3 " C 2112 0 DOWEL HOLES #5 S1 D ° ° ° 3/q „ SHEAR KEY DETAIL END ELEVATION SHOWING PLACEMENT OF DOUBLE STIRRUPS AND LOCATION OF DOWEL HOLES. (STRAND LAYOUT NOT SHOWN.) INTERIOR SLAB UNIT SHOWN -EXTERIOR SLAB UNIT SIMILAR EXCEPT SHEAR KEY LOCATION. NOTE -OMIT SHEAR KEY ON OUTSIDE FACE OF EXTERIOR CORED SLABS. DOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED PERMITTED THREADED INSERT CAST IN OUTSIDE FACE OF EXTERIOR UNIT AND RECESSED %"o SIZE TO BE DETERMINED BY CONTRACTOR.---7 THREADED INSERT DETAIL PROJECT NOo B-5323 GRANVILLE COUNTY STATION- 14+66.00 -L- SHEET 1 OF 8 15'-01, 15'-0" 15'-0" I c_o M i H z m a Q w � u o o a w 0 w ry, 0 0 Cr a w w w 0 w 0 Q0 z 0 0 0 w w w w w N N SEE DE (TYP.) wd i3 C <' 7 PLAN OF UNIT —00'-001, (TYP.) 0 6" 7—#4 S2 PAIRS 2 9" CTS. 2 112 „ 0 DOWEL HOLES #4 S2 PAIRS Q 1'-0" CTS. 1„ CLo T { 2—#5 S1 1111 -—-—— --------------- �2 ------------- ———— — — — — —— -- -- — i ---a-- --------- -- 21/2" 8—#5 S3 Q 6" CTS. r� ►-r 3,-0'/ DETAIL "A" 12" � VOIDS #5 S3 (�) 1'-0"CTS. 3 1/2 (TYPICAL EACH END OF UNIT) NOTE. EXTERIOR UNIT SHOWN — INTERIOR UNIT SIMILAR EXCEPT OMIT #5 S3 BARS. DOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED PROJECT NOe B-5323 GRANVILLE COUNTY STATION: 14+66.00 -L- SHEET 2 OF 8 18'-4" 18'-4„ 18'-4" 1 N CV SEE DE (TYP.) rd i Lr_\IN vi u I N I i 7—#4 S2 PAIRS 2 9"CTSo 2 0 (DOWEL HOLES #4 S2 PAIRS (a7 1'-0" CTSo _#5 S1 — L----- ------------------ --------------- _1 ------------ ---- - - - -- -- — i -- -#5 S3 2 6"CTSo DETAIL "A" 12" 0 VOIDS #5 S3 (D 1'-0" CTSo 3 1/2 YPICAL EACH END OF UNIT) (TERIOR UNIT SHOWN — INTERIOR .MILAR EXCEPT OMIT #5 S3 BARS. PROJECT NOo B-5323 GRANVILLE COUNTY STATION: 14+66.00 -L- SHEET 3 OF 8 NOTES c� N Lo rd -04 -64 � w w � a V) z w >_ 0 0 V) o D f* fol� fol� BILL OF MATERIAL 45'CORED SLAB FOR UNIT ONE EXTERIOR UNIT INTERIOR UNIT BAR NUMBER SIZE TYPE LENGTH WEIGHT LENGTH WEIGHT B5 4 #4 STR 23'-3" 62 23'-3" 62 S1 8 #5 3 4'-3" 35 4'-3" 35 S2 94 #4 3 5'-4" 335 5'-4" 335 S3 54 #5 1 6'-0" 338 REINFORCING STEEL LBS. 432 432 EPDXY COATED REINFORCING STEEL LBS. 338 5000 P.S.I. CONCRETE CU. YDS. 6.5 6.5 Oo6" 0 L.R. STRANDS No. 13 13 BILL OF MATERIAL 55'CORED SLAB FOR UNIT ONE EXTERIOR UNIT INTERIOR UNIT BAR NUMBER SIZE TYPE LENGTH WEIGHT LENGTH WEIGHT B7 4 #4 STR 28'-3" 75 28'-3" 75 S1 8 #5 3 4'-3" 35 4'-3" 35 S2 114 #4 3 5'-4" 406 5'-4" 406 S3 64 #5 1 6'-0" 401 REINFORCING STEEL LBS. 516 516 EPDXY COATED REINFORCING STEEL LBS. 401 6500 P.S.I. CONCRETE CU. YDS. 7.8 7.8 Oo6" 0 L.R. STRANDS No. 19 19 DEAD LOAD DEFLECTION AND CAMBER 3'-0'/ x 1'-9" 45' CORED SLAB UNIT 0.6/'0 L.R. STRAND CAMBER ( SLAB ALONE IN PLACE ) 7/8" # DEFLECTION DUE TO SUPERIMPOSED DEAD LOAD 1/8„ i FINAL CAMBER 3/4" INCLUDES FUTURE WEARING SURFACE DEAD LOAD DEFLECTION AND CAMBER 3,-0"x 1'-9/ 55' CORED SLAB UNIT Oo6" 0 L.R. STRAND CAMBER ( SLAB ALONE IN PLACE ) 11/2" DEFLECTION DUE TO SUPERIMPOSED DEAD LOAD 3 „ /a i FINAL CAMBER INCLUDES FUTURE WEARING SURFACE CONCRETE RELEASE STRENGTH UNIT PSI 45' UNITS 4000 55' UNITS 4900 GRADE 270 STRANDS 0.6/'0 L.R. AREA ( SQUARE INCHES ) Oo217 ULTIMATE STRENGTH 58,600 ( LBS. PER STRAND ) APPLIED PRESTRESS 43,950 ( LBS. PER STRAND ) CORED SLABS REQUIRED NUMBER LENGTHTOTAL LENGTH 45' UNIT EXTERIOR C.S. 4 45'-0" 180'-0" INTERIOR C.S. 20 45'-0/' 900'-0" TOTAL 24 1080'-0" 55' UNIT EXTERIOR C.S. 4 55'-0" 220'-0" INTERIOR C.S. 20 55'-0" 1100'-0" TOTAL 24 1320'-0' Qo N BAR TYPES 9 1/2 (D Ln H 8„ 53/4„ S1 1'-9" S2 2'-8" N O ALL BAR DIMENSIONS ARE OUT TO OUT ALL PRESTRESSING STRANDS SHALL BE 7-WIRE LOW RELAXATION GRADE 270 STRANDS AND SHALL CONFORM TO AASHTO M203 EXCEPT FOR SAMPLING REQUIREMENTS WHICH SHALL BE IN ACCORDANCE WITH THE STANDARD SPECIFICATIONS° ALL REINFORCING STEEL CAST WITH THE CORED SLAB SECTIONS SHALL BE GRADE 60 AND SHALL BE INCLUDED IN THE UNIT PRICE BID FOR PRESTRESSED CONCRETE CORED SLABS. RECESSES FOR TRANSVERSE STRANDS SHALL BE GROUTED AFTER THE TENSIONING OF THE STRANDS. THE 21/2"0 DOWEL HOLES AT FIXED ENDS OF SLAB SECTIONS SHALL BE FILLED WITH NON -SHRINK GROUT. THE BACKER RODS SHALL CONFORM TO THE REQUIREMENTS OF TYPE M BOND BREAKERoSEE SECTION 1028 OF THE STANDARD SPECIFICATIONS° WHEN CORED SLABS ARE CAST, AN INTERNAL HOLD-DOWN SYSTEM SHALL BE EMPLOYED TO PREVENT VOIDS FROM RISING OR MOVING SIDEWAYS. AT LEAST SIX WEEKS PRIOR TO CASTING CORED SLABS, THE CONTRACTOR SHALL SUBMIT TO THE ENGINEER FOR REVIEW AND COMMENT, DETAILED DRAWINGS OF THE PROPOSED HOLD-DOWN SYSTEM. IN ADDITION TO STRUCTURAL DETAILS, LOCATION AND SPACING OF THE HOLD-DOWNS SHALL BE INDICATED° ALL REINFORCING STEEL IN THE VERTICAL CONCRETE BARRIER RAIL SHALL BE EPDXY COATED. PRESTRESSING STRANDS SHALL BE CUT FLUSH WITH THE CORED SLAB UNIT ENDS. APPLY EPDXY PROTECTIVE COATING TO CORED SLAB UNIT ENDS. GROOVED CONTRACTION JOINTS,/2" IN DEPTH, SHALL BE TOOLED IN ALL EXPOSED FACES OF THE BARRIER RAIL AND IN ACCORDANCE WITH ARTICLE 825-10(B)OF THE STANDARD SPECIFICATIONS.A CONTRACTION JOINT SHALL BE LOCATED AT EACH THIRD POINT BETWEEN BARRIER RAIL EXPANSION JOINTS. ONLY ONE CONTRACTION JOINT IS REQUIRED AT MIDPOINT OF BARRIER RAIL SEGMENTS LESS THAN 20 FEET IN LENGTH AND NO CONTRACTION JOINTS ARE REQUIRED FOR THOSE SEGMENTS LESS THAN 10 FEET IN LENGTH. FLAME CUTTING OF THE TRANSVERSE POST -TENSIONING STRAND IS NOT ALLOWED. THE TRANSFER OF LOAD FROM THE ANCHORAGES TO THE CORED SLAB UNIT SHALL BE DONE WHEN THE CONCRETE HAS REACHED A COMPRESSIVE STRENGTH OF NOT LESS THAN THE REQUIRED STRENGTH SHOWN IN THE "CONCRETE RELEASE STRENGTH" TABLE. FOR GROUT FOR STRUCTURES, SEE SPECIAL PROVISIONS° THE PERMITTED THREADED INSERTS ARE DETAILED AS AN OPTION FOR THE CONTRACTOR TO ATTACH FALSEWORK AND FORMWORK DURING CONSTRUCTION. THE PERMITTED THREADED INSERTS IN THE EXTERIOR UNITS SHALL BE SIZED BY THE CONTRACTOR, SPACED AT 4'-0"CENTERS AND GALVANIZED IN ACCORDANCE WITH SECTION 1076 OF THE STANDARD SPECIFICATIONS° STAINLESS STEEL THREADED INSERTS MAY BE USED AS AN ALTERNATE. THE PERMITTED THREADED INSERTS SHALL BE GROUTED BY THE CONTRACTOR BEARING PAD IMMEDIATELY FOLLOWING REMOVAL OF THE FALSEWORK. 8 � THE COST OF THE PERMITTED THREADED INSERTS SHALL BE INCLUDED IN THE PRICE BID FOR THE PRECAST UNITS. C 1" 0 HOLES SEARING PAD - TYPE I - FIXED END ( TYPE I - 96 REQ' D ) ELASTOMERIC BEARING DETAILS ELASTOMER IN ALL BEARINGS SHALL BE 50 DUROMETER HARDNESS. DOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED PROJECT NO. B-5323 GRANVILLE COUNTY STATION: SHEET 4 OF 8 14+66.00 -L- c� N Lo 'fig 1'-4" SFF "RATI POST SPA(TNGS ANF) FNF) OF RATI F)FTATI S" SHFFT 1'-4" 9/6„ X SLOTS (TYP.) (3 0 0 CV 5y PLAN 2 7/s 17/s „ 17/s O lof ELEVATION NOTE .- FOR ATTACHMENT OF METAL RAIL TO END POST, SEE STANDARD NO. BMR2o /16 i 5/16" 0 DRILL 1" DEEP & 4 — .766" 0 HOLES %" 0 [16 THREAD] TAP PUNCHED FOR RIVETS 7/s" DEEP FOR %" 0 X 1 1/2" STAINLESS STEEL CAP SCREW FRONT ELEVATION SIDE ELEVATION DETAILS OF POST 1'-2" 1 1/211 CV Ln En o M o I 0750" e745" RIVET DETAIL 4— Y4" 0 BOLTS WITH ROUND WASHERS ANCHOR ASSEMBLY 16 6 „ oJTo 15 �6 .L) 4 /s SECTION THRU PARAPET AND RAIL Ln 0 5)4 4 — 0766" 0 Y8„ 1„ 33/4„ HOLES PUNCHED FOR RIVETS 0 `s' —0 0 N --r r----r r----r r-- PERMITTED WEL FRONT ELEVATION 7/$ HOLES NOTES AT THE CONTRACTOR'S OPTION, METAL RAIL MAY BE EITHER ALUMINUM OR GALVANIZED STEEL IN ACCORDANCE WITH THE REQUIREMENTS OF THE GENERAL NOTES AND THE FOLLOWING SPECIFICATIONS FOR THE ALTERNATE MATERIALS- HOWEVER,THE CONTRACTOR WILL BE REQUIRED TO USE THE SAME RAIL MATERIAL ON ALL STRUCTURES ON THE PROJECT FOR WHICH METAL RAIL IS DESIGNATED. UNLESS OTHERWISE REQUIRED IN THE CONTRACT DOCUMENTS, THE CONTRACTOR HAS THE OPTION TO USE AN ALTERNATE TO THE 2 BAR METAL RAIL. THE ALTERNATE RAIL SHALL MEET THE REQUIREMENTS OF THE AASHTO LRFDBRIDGE DESIGN SPECIFICATIONS AND MUST BE LISTED ON THE DEPARTMENT'S APPROVED PRODUCTS LIST (APL) UNDER "2 BAR METAL RAIL ALTERNATE". ADJUSTMENTS TO THE CONCRETE PARAPET WILL NOT BE ALLOWED. ALUMINUM RAILS MATERIAL FOR POSTS, BASES AND RAILS, EXPANSION BARS AND CLAMP BARS SHALL BE ASTM B-221 ALLOY 6061—T6o MATERIAL FOR RIVETS SHALL BE ASTM B316 ALLOY 6061—T6o RIVETS SHALL BE STANDARD BUTTON HEAD AND CONE POINT COLD DRIVEN AS PER DRAWING. THE BASE OF RAIL POSTS, OR ANY OTHER ALUMINUM SURFACE IN CONTACT WITH CONCRETE SHALL BE THOROUGHLY COATED WITH AN ALUMINUM IMPREGNATED CAULKING COMPOUND OF APPROVED QUALITY° MATERIAL FOR SHIMS TO BE ASTM B209 ALLOY 6061—T6o GALVANIZED STEEL RAILS MATERIAL AND GALVANIZING ARE TO CONFORM TO THE FOLLOWING SPECIFICATIONS° POST, POST BASES, RAILS, EXPANSION BARS AND CLAMP BARS.- AASHTO M270 GRADE 36 STRUCTURAL STEEL — GALVANIZED TO AASHTO M1110 RIVETS.- RIVETS SHALL MEET THE REQUIREMENTS OF ASTM A502 FOR GRADE 1 RIVETS° THE CUT ENDS OF GALVANIZED STEEL RAILING, AFTER GRINDING SMOOTH SHALL BE GIVEN TWO COATS OF ZINC RICH PAINT MEETING THE REQUIREMENTS OF FEDERAL SPECIFICATION MIL—P-26915 USAF TYPE 1, OR OF FEDERAL SPECIFICATIONS TT—P-6410 SHIMS.- SHIMS SHALL MEET THE REQUIREMENTS OF ASTM A570 FOR GRADE 33 OR A611 FOR GRADE C AND SHALL BE GALVANIZED IN ACCORDANCE WITH AASHTO M1110 RAIL CAPS.- RAIL CAPS SHALL MEET THE REQUIREMENTS OF ASTM A570 FOR GRADE 33 OR A611 FOR GRADE C AND SHALL BE GALVANIZED IN ACCORDANCE WITH AASHTO M1110 GENERAL NOTES RAILING SHALL BE CONTINUOUS FROM END POST TO END POST OF BRIDGE. EACH JOINT IN RAIL LENGTH SHALL BE SPLICED AS DETAILED° PANEL LENGTHS OF RAIL SHALL BE ATTACHED TO A MINIMUM OF THREE POSTS. FOR END OF RAIL TO CLEAR FACE OF CONCRETE END POST DIMENSION, SEE STANDARD NO.BMR2o CAP SCREWS SHALL BE ASTM F595 ALLOY 505 STAINLESS STEEL. WASHERS SHALL MEET THE REQUIREMENTS OF ASTM F844 EXCEPT THEY SHALL BE MADE FROM ALLOY 304 STAINLESS STEEL. CERTIFIED MILL REPORTS ARE REQUIRED FOR RAILS AND POSTS. SHOP INSPECTION IS NOT REQUIRED° METAL RAIL POSTS SHALL BE SET NORMAL TO CURB GRADE. METHOD OF MEASUREMENT FOR METAL RAILS.- FOR LENGTH OF METAL RAILS TO BE PAID FOR, SEE THE STANDARD SPECIFICATIONS° CURVED RAIL USAGE.- WHERE RAILS ARE TO BE USED ON BRIDGES ON HORIZONTAL AND/OR VERTICAL CURVATURE THE CONTRACTOR MAY, AT HIS OPTION, HAVE THE REQUIRED CURVATURE IN THE RAIL FORMED IN THE SHOP OR IN THE FIELD. IN EITHER EVENT, THE RAIL SHALL CONFORM WITHOUT BUCKLING OR KINKING TO THE REQUIRED CURVATURE IN A UNIFORM MANNER ACCEPTABLE TO THE ENGINEER° TO INSURE FUTURE IDENTIFICATION OF THE FABRICATOR,A PERMANENT IDENTIFYING MARK SHALL BE PLACED ON EACH POST. THE METHOD OF MARKING AND LOCATION SHALL BE SUCH THAT IT DOES NOT DETRACT FROM THE APPEARANCE OF THE POST, BUT REMAINS VISIBLE AFTER RAIL PLACEMENT. SHIMS SHALL BE USED AS NECESSARY FOR POST ALIGNMENT° ALLOY 6351—T5 MAY BE SUBSTITUTED FOR ALLOY 6061—T6 WHERE APPLICABLE. MINOR VARIATIONS IN DETAILS OF METAL RAIL WILL BE CONSIDERED. DETAILS OF SUCH VARIATIONS, IF DESIRED, SHALL BE SUBMITTED FOR APPROVAL. GROOVED CONTRACTION JOINTS, 1/2"IN DEPTH, SHALL BE TOOLED IN ALL EXPOSED FACES OF THE PARAPET AND IN ACCORDANCE WITH ARTICLE 825-10(B)OF THE STANDARD SPECIFICATIONS.A CONTRACTION JOINT SHALL BE LOCATED AT EACH THIRD POINT BETWEEN PARAPET EXPANSION JOINTS. ONLY ONE CONTRACTION JOINT IS REQUIRED AT MIDPOINT OF PARAPET SEGMENTS LESS THAN 20 FEET IN LENGTH AND NO CONTRACTION JOINTS ARE REQUIRED FOR THOSE SEGMENTS LESS THAN 10 FEET IN LENGTH. 0 DRILL & COUNTER BORE + %" 0 [16 THREAD] CAP SCREW PLAN 25/6„ 1/4 „ NOTE .-BASE CAN BE SUPPLIED AS ONE EXTRUSION OR TWO EXTRUSIONS WELDED TOGETHER AS SHOWN. `N D 2„ 21/4„ SIDE ELEVATION POST BASE DETAILS PAY LENGTH = 385.75 LIN. FT. DOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED PROJECT NOo B-5323 GRANVILLE STATION: SHEET 5 OF 8 COUNTY 14+66.00 -L- cn N Lo wig -64 -64 � w w � �if�n_ V) z w >_ 0 un V) o D f* � � � � � * * _0� DIMPLE "B" 'Q a \ H 0 \—DIMPLE '\A" I/8 SECTION B — B DIMPLE TO FIT RAIL SECTION EXPANSION BAR DETAILS /2" 0 [13 THREAD] HOLE FOR 1/2" 0 X 1" STAINLESS STEEL HEX HEAD CAP SCREW & 1%16" O.Do, 17/32" I.De, TIIT(`1/ IA/ A C'IIrm /T VM \ \N CV 7/32" uo CAMP BAR DETAIL (4 REQUIRED PER POST ) Ln SIDE VIEW TYP.) 0.375" 0 WIRE STRUT PLAN 5/8 FIT 3/4" 0 BOLT WITH THREADED STEEL INSERTS WITH CLOSED BOTTOM TO ROUND WASHER. ELEVATION RPW 4-BOAT METAL RAID ANCHOR ASSEMBLY 411 3 I/32" 21/32" y6, r� --/ MINOR AXIS BAR SECTION 9/32'' r 7/32" 2 3/3 2 1 1/32„ I/16 66 ASSEMBLIES REQUIRED 7/8" 0 HOLES (PERMITTED CUTLINE ) 2 I/4 M Ln FRONT PATE NOTES STRUCTURAL CONCRETE ANCHOR ASSEMBLY THE STRUCTURAL CONCRETE ANCHOR ASSEMBLY SHALL CONSIST OF THE FOLLOWING COMPONENTS A. FERRULES SHALL BE MADE FROM STEEL MEETING THE REQUIREMENTS OF AASHTO M169, GRADE 12L14 AND SHALL HAVE A MINIMUM LENGTH OF THREADS OF 2" FOR Y4" FERRULES. Bo 4 — Y4" 0 X 21/2" BOLTS WITH WASHERS. BOLTS SHALL CONFORM TO THE REQUIREMENTS OF ASTM A307o BOLTS AND WASHERS SHALL BE GALVANIZED° AT THE CONTRACTOR'S OPTION, STAINLESS STEEL BOLTS AND WASHERS MAY BE USED AS AN ALTERNATE FOR THE 3/4" 0 X 21/2" GALVANIZED BOLTS AND WASHERS. THEY SHALL CONFORM TO OR EXCEED THE MECHANICAL REQUIREMENTS OF ASTM A307e THE USE OF THIS ALTERNATE SHALL BE APPROVED BY THE ENGINEER° Co WIRE STRUT SHOWN IN THE CONCRETE ANCHOR ASSEMBLY DETAIL IS THE MINIMUM ALLOWABLE SIZE AND SHALL HAVE A MINIMUM TENSILE STRENGTH OF 100,000 PSI. AS AN OPTION, A 7/6" 0 WIRE STRUT WITH A MINIMUM TENSILE STRENGTH OF 90,000 PSI IS ACCEPTABLE. Do THE METAL RAIL ANCHOR ASSEMBLIES TO BE HOT DIPPED GALVANIZED TO CONFORM TO REQUIREMENTS OF AASHTO M1110 E. THE COST OF THE METAL RAIL ANCHOR ASSEMBLY WITH BOLTS AND WASHERS COMPLETE IN PLACE SHALL BE INCLUDED IN THE PRICE BID FOR LINEAR FEET OF METAL RAIL. F. BOLTS TO BE TIGHTENED ONE—HALF TURN WITH A WRENCH FROM A FINGER —TIGHT POSITION. THE CONTRACTOR MAY USE ADHESIVELY ANCHORED ANCHOR BOLTS IN PLACE OF THE METAL RAIL ANCHOR ASSEMBLY. LEVEL ONE FIELD TESTING IS REQUIRED, AND THE YIELD LOAD OF THE 3/4"O BOLT IS 10 KIPS. FOR ADHESIVELY ANCHORED ANCHOR BOLTS OR DOWELS, SEE THE STANDARD SPECIFICATIONS. WHEN ADHESIVELY ANCHORED ANCHOR BOLTS ARE USED, BOLTS SHALL MEET THE REQUIREMENTS OF ASTM F593 ALLOY 304 STAINLESS STEEL WITH MINIMUM 75,000 PSI ULTIMATE STRENGTH. NUTS SHALL MEET THE REQUIREMENTS OF ASTM F594 ALLOY 304 STAINLESS STEEL AND WASHERS SHALL MEET THE REQUIREMENTS OF ASTM F844 EXCEPT THEY SHALL BE MADE FROM ALLOY 304 STAINLESS STEEL. REAR PLATE SHIM DETAILS NOTE SHIMS MAY BE CUT ALONG PERMITTED CUTLINE OR SLOTTED TO EDGE OF PLATE TO FACILITATE PLACEMENT. CLAMP ASSEMBLY RAIL CAP 7/8" 0 HOLES (PERMITTED CUTLINE) DOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED 4 3/4 Y4" 15/32„ 1/8 I/211 1/4 „ SEMI —(ELLIPSE YI 6 " I 5�6 I MINOR AXIS RAIL SECTION MAJOR AXIS PROJECT NOo B-5323 GRANVILLE STATION: SHEET 6 OF 8 COUNTY 14+66.00 —L— NOTES c� N Lo .. -04 -64 � w w � a n- V) z w >- 0 0 V) o D f* fol� fol� I/2 " E 2 SPACES 2 1'-111/2" C RAIL POST (TYPo) '-6" 3'-0" YP.) I (TYPo) YP.) I (TYP ) 6'-0" 1 6„ (TYPo) (TYPo) 2 SPACES 1'-111/2" ON 1 ' - 4 " r N) l )r r T I I r n nr — C 11/2" 0 HOLE 11" i X 1" SLOTS 3 ELEVATION (` I-�/ r, v i„ r-i nTr 2 � —I 1— TOP VIEW PLAN OF RAIL POST SPACINGS- ANGLE TO BE MADE FROM 1/2" X 4" X 11" E AND I/211 X 411 X 411 M 4" 2" 2" i 11/2" 0 HOLE c� 7/8 „ i 7/8 � L END VIEW (FIX AND EXP.) RAIL --)r-- ICI STANDARD CLAMP BAR �/21' 0 113 THREAD] X 11/4" STAINLESS STEEL HEX HEAD CAP SCREWS & 1/2„ 11/16/' O.D., 17/32// I.D., 1/16'/ THICK WASHER SECTION H—H (FIX) FIXED 1'-4" CL RAIL POST H ATTACHMENT BRACKET 41 /"-1 RAIL SECTION STANDARD BAR CLAMP STRUCTURAL CONCRETE INSERT THE STRUCTURAL CONCRETE INSERT ASSEMBLY SHALL CONSIST OF THE FOLLOWING COMPONENTS. A. FERRULES SHALL BE MADE FROM STEEL MEETING THE REQUIREMENTS OF AASHTO M169, GRADE 12L14 AND SHALL HAVE A MINIMUM LENGTH OF THREADS OF 11/21' 0 Bo 1 — %4" 0 X 15/$" BOLT WITH WASHER. BOLT SHALL CONFORM TO THE REQUIREMENTS OF ASTM A307o BOLT AND WASHER SHALL BE GALVANIZED° (AT THE CONTRACTOR'S OPTION, STAINLESS STEEL BOLT AND WASHER MAY BE USED AS AN ALTERNATE FOR THE 3/4" 0 X 15/8" GALVANIZED BOLT AND WASHER. THEY SHALL CONFORM TO OR EXCEED THE MECHANICAL REQUIREMENTS OF ASTM A307o THE USE OF THIS ALTERNATE SHALL BE APPROVED BY THE ENGINEER°) C. WIRE STRUT SHOWN IN THE CONCRETE INSERT ASSEMBLY DETAIL IS THE MINIMUM ALLOWABLE SIZE AND SHALL HAVE A MINIMUM TENSILE STRENGTH OF 100,000 PSI. AS AN OPTION, A 7/6" O WIRE STRUT WITH A MINIMUM TENSILE STRENGTH OF 90,000 PSI IS ACCEPTABLE. NOTES METAL RAIL TO END POST CONNECTION THE METAL RAIL TO END POST CONNECTION SHALL CONSIST OF THE FOLLOWING COMPONENTS. A.112" PLATES SHALL CONFORM TO AASHTO M270 GRADE 36 AND SHALL BE GALVANIZED AFTER FABRICATION° Bo %4" STRUCTURAL CONCRETE INSERT SHALL HAVE A WORKING LOAD SHEAR CAPACITY OF 4800 LBS. THE FERRULES SHALL ENGAGE A %4"O X 1%'/ BOLT WITH 2" O.D. WASHER IN PLACE. THE 3/4110 X 1%- BOLT SHALL HAVE No Co THREADS. Co CAP SCREWS FOR RAIL ATTACHMENT TO ANGLE SHALL CONFORM TO THE REQUIREMENTS OF ASTM F593 ALLOY 305 STAINLESS STEEL. CAP SCREWS TO BE CENTERED IN SLOTS AT 60°Fe Do STANDARD CLAMP BARS (SEE METAL RAIL SHEET). E. 1/21' 0 PIPE SLEEVES (IF REQUIRED) TO BE GALVANIZED. THE COST OF THE STANDARD CLAMP BARS AND CAP SCREWS USED IN THE METAL RAIL TO END POST CONNECTION SHALL BE INCLUDED IN THE UNIT CONTRACT PRICE BID FOR LINEAR FEET OF 1 OR 2 BAR METAL RAILS. THE 3/4" STRUCTURAL CONCRETE INSERT WITH BOLT SHALL BE ASSEMBLED IN THE SHOP. THE COST OF THE 3/4" STRUCTURAL CONCRETE INSERT ASSEMBLY, AND THE 1/2" PLATES COMPLETE IN PLACE SHALL BE INCLUDED IN THE VARIOUS PAY ITEMS. THE CONTRACTOR, AT HIS OPTION, MAY USE AN ADHESIVE BONDING SYSTEM IN LIEU OF THE STRUCTURAL CONCRETE INSERT EMBEDDED IN THE END POST. IF THE ADHESIVE BONDING SYSTEM IS USED, THE 3/4" 0 X 1%// BOLT WITH WASHER SHALL BE REPLACED WITH A %4'/O X 61/2" BOLT AND 2" O.D. WASHER. ALL SPECIFICATIONS THAT APPLY TO THE 3/4" 0 X 15/8" BOLT SHALL APPLY TO THE 3/4"O X 6 1/2" BOLT. FIELD TESTING OF THE ADHESIVE BONDING SYSTEM IS NOT REQUIRED° %4" O X 15/8" BOLT AND 2" O.D.WASHER 3/4„ STRUCTURAL CONCRETE INSERT C 1/2" 0 [13 THREAD] X 11/4'1 H ROADWAY STAINLESS STEEL HEX HEAD CAP FACE SCREWS & 11/16" O.D., 17/32" I.D., 11211 1/16" THICK WASHER PLAN — RAIL AND END POST R.P.W.( TYP.ALL CONTACT POINTS ) FERRULE t.37E WIRE PLAN LUSLU-LNU ERRULE x 0 w w a ELEVATION STRUCTURAL CONCRETE INSERT *EACH WELDED ATTACHMENT OF WIRE TO FERRULE SHALL DEVELOP THE TENSILE STRENGTH OF THE WIRE. nP-TATI � P-nP ATTArPTNI(; KAP-TAI P A T I Tn P-Nin P(1l:�T 7 7/8 DOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED PROJECT NOo B-5323 GRANVILLE STATION: SHEET 7 OF 8 COUNTY 14+66.00 -L- STD. NO. BMR2 .. -04 -64 {�} � w w a rr V) z w >- 0 0 V) o z f* fol� fol� 31/2" SEE DETAIL "A" FOR S3 SPACING (SHEET 2 OF 8 & 3 OF 8) CV I #5 B1 OR B2 PLAN OF PARAPET #5 S3 UNIT r UK JI-'AUiINU) 3'-9" END POST r FILL FACE —01 END BENT #1 WoPa #1 i f 1'-2" END VIEW PERMITTED CONST. JTo 3'-g„ #7 „F" BARS 2 2i/�„ ANCHOR ASSEMBLY PLAN OF END POST 3'-g„ � GUARDRAIL JCHOR ASSEMBLY #7 F1 6" #7 "E" BARS 21/2' 91/2" CTS. (EA. FACE) (� CONC. INSERTS ELEVATION PARAPET AND END POST FOR TWO BAR RAIL SECTION T-T AT OPEN JOINT AT BENT (THIS IS TO BE USED WHERE FOAM JOINT IS NOT USED) N i N C� m �6 #5 B9 ITTED N F. JTo #5 S5 3" SECTION S-S AT DAM IN OPEN JOINT (THIS IS TO BE USED ONLY WHEN SLIP FORM IS USED ) C 1/2" EXP. JTo MAT'L HELD IN PLACE WITH GALVANIZED NAILS. (NOTE: OMIT EXP. JTe MAT'L. WHEN SLIP FORM IS USED) OPEN JTo IN T S RAIL Q BENT CHAMFE CHAMFER CONST. J `pT +S ELEVATION AT EXPANSION JOINTS 45'-0Y4„ 45'-11/2„ 55,-11/2„ 55,-O3/4„ 22,-6„ 22'-63/4„ 22/-63/4„ 22/-6 Y4// 27'-63/4„ 27' 27'-6 Y4„ 27'-6„ Do 46 - #5 S6 54 - #5 S6 64 - #5 S6 56 - #5 S6 (TO MATCH #5 S3 BARS IN i (TO MATCH #5 S3 BARS 3/2 i „ (TO MATCH #5 S3 BARS 3/2 i „ (TO MATCH #5 S3 BARS 3/2 CORED SLABS) IN CORED SLABS) IN CORED SLABS) IN CORED SLABS) 3 i/2 „ i i i i i i i i i i i i i i i i i I i i I J1 1/2"EXPO JTo 8 - #5B8 ! 8 - #5B8 ! 8 - #5B9 8 - #5B9 i (TYPo EAo (TYPo EAo (TYPo EAo (TYPo EAo MATERIAL SECTION SECTION ; SECTION SECTION (TYPo) SPAN A) -L- SPAN B) SPAN C) SPAN D) i i WoPo #2 W. #3 i 4 WoPo #4 CONTROL LINE BENT 1CONTROL LINE BENT 2 CONTROL LINE BENT 3 SPAN A SPAN B ; SPAN C PLAN OF PARAPET LEFT PARAPET SHOWN, RIGHT PARAPET SIMILAR io-is FOR SPACING OF #5S3 BARS OUTSIDE OF END POST, SEE SHEETS 2 OF 8 & 3 OF 8 SPAN D 3'-g„ END POST FILL FACE END BENT #2 W.P. #5 u� #5 S6 a . m #5 S3 00 a a 3CL. 0 N 3 �I PARAPET SECTION THE HEIGHT OF THE PARAPET VARIES WHILE THE TOP OF THE PARAPET FOLLOWS THE PROFILE OF THE GUTTERLINE. GUTTEREINE ASPHALT THICKNESS & RAIL HEIGHT ASPHALT OVERLAY THICKNESS PARAPET HEIGHT 2 MID -SPAN Cad MID -SPAN 45' UNITS 23/4" 2'-8%4" 55' UNITS 2%11 2'-8%// DOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED m o o6 'D6 Q PROJECT N0. B-5323 GRANVILLE COUNTY STATION: 14+66.00 -L- SHEET 8 OF 8 NOTES THE GUARDRAIL ANCHOR ASSEMBLY SHALL CONSIST OF A '/q"HOLD DOWN PLATE AND 7 — 7/8" 0 BOLTS WITH NUTS AND WASHERS. N c� Lo .. -04 -64 � w w � a V) z w >- 0 0 V) o D f* fol� fol� CL GUARDRAIL ANCHOR ASSE C 1�/16" 0 HOLES ( '/q" HOLD—DOW 11" 1 411 " 411 " 1 GUARDRAIL ANCHOR ASSEMBLY CL GUARDRAIL ANCHOR ASSEMBLY 7/8// 0 X 1'-4" B( WITH ROL WASHERS (T) 1 1/q „ I IV L L \ I I I o/ PLAN GUARDRAIL ANCHOR ASSEMBLY DETAILS (� JTo 2 END BENT END VIEW (TWO BAR METAL RAIL) PLAN 1'-2" END VIEW LOCATION OF GUARDRAIL ANCHOR AT END POST ]OLD —DOWN E THE HOLD—DOWN PLATE SHALL CONFORM TO AASHTO M270 GRADE 36.AFTER FABRICATION, THE HOLD—DOWN PLATE SHALL BE HOT —DIP GALVANIZED IN ACCORDANCE WITH AASHTO M1110 BOLTS SHALL CONFORM TO THE REQUIREMENTS OF ASTM A307 AND NUTS SHALL CONFORM TO THE REQUIREMENTS OF AASHTO M2910 BOLTS, NUTS AND WASHERS SHALL BE GALVANIZED. AT THE CONTRACTOR'S OPTION, STAINLESS STEEL BOLTS, NUTS AND WASHERS MAY BE USED AS AN ALTERNATE FOR THE 7/8" 0 GALVANIZED BOLTS, NUTS AND WASHERS. THEY SHALL CONFORM TO OR EXCEED THE MECHANICAL REQUIREMENTS OF ASTM A307.THE USE OF THIS ALTERNATE SHALL BE APPROVED BY THE ENGINEER. THE GUARDRAIL ANCHOR ASSEMBLY IS REQUIRED AT ALL POINTS WHERE APPROACH GUARDRAIL IS TO BE ATTACHED TO THE END OF THE PARAPET. FOR POINTS OF ATTACHMENT, SEE SKETCH. AFTER INSTALLATION, THE EXPOSED THREAD OF THE BOLT SHALL BE BURRED WITH A SHARP POINTED TOOL. THE COST OF THE GUARDRAIL ANCHOR ASSEMBLIES WITH BOLTS, NUTS AND WASHERS COMPLETE IN PLACE, SHALL BE INCLUDED IN THE VARIOUS PAY ITEMS. THE VERTICAL REINFORCING BARS MAY BE SHIFTED SLIGHTLY IN THE END POST TO CLEAR ASSEMBLY BOLTS. THE 1'/4" 0 HOLES SHALL BE FORMED OR DRILLED WITH A CORE BIT. IMPACT TOOLS WILL NOT BE PERMITTED° ANY CONCRETE DAMAGED BY THIS WORK SHALL BE REPAIRED TO THE SATISFACTION OF THE ENGINEER. r IT n CL JTo (;D END BENT #2 SKETCH SHOWING POINTS OF ATTACHMENT *LOCATION OF GUARDRAIL ATTACHMENT DOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED PROJECT NO. B-5323 GRANVILLE COUNTY STATION° 14+66.00 -L- (SHT 2) STD. NO. GRA3 .. -04 -64 � w w � a V) z w >_ 0 0 V) o D f* fol� fol� POUR #2 UPPER PAf OF WING` POUR #1 CAP, LOWEI PART OF WIN( CONCRETE COL c il -L- 42'-0" PLAN Q O O O O ELEVATION WINGS NOT SHOWN FOR CLARITY. FOR SECTION A -A, SEE SHEET 4 OF 10. 1 CONCRETE COLLARS FOR STEEL PILES NOT SHOWN IN PLAN AND ELEVATION VIEWS FOR CLARITY° SEE "CORROSION PROTECTION FOR STEEL PILES DETAIL", SHEET 4 OF 10. 0 1'-0" .4 To JT. 'Po) 306.75 302.75 DM OF CAP WING 14 S1 & #4 S2 IYP. EACH END) DOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED NOTES STIRRUPS IN CAP MAY BE SHIFTED AS NECESSARY TO CLEAR DOWELS. THE CONCRETE IN THE SHADED AREA OF THE WING SHALL BE POURED AFTER THE VERTICAL CONCRETE BARRIER RAIL IS CAST IF SLIP FORMING IS USED. FOR PILE SPLICE DETAILS, SEE SHEET 4 OF 10.1 FOR WING DETAILS, SEE SHEET 3 OF 10. PROJECT NO. B-5323 GRANVILLE COUNTY STATION: SHEET 1 OF 10 14+66.00 -L- STD. NO. EB-36-9OS4 NOTES c� N Lo rd -04 -64 � w w � a n_ V) z w >_ 0 0 V) o D f* fol� fol� POUR #2 UPPER PAf OF WING` POUR #1 CAP, LOWEI PART OF WIN( CONCRETE COL *1 I PLAN O Q O O O O O ELEVATION WINGS NOT SHOWN FOR CLARITY. FOR SECTION A -A, SEE SHEET 4 OF 10. CONCRETE COLLARS FOR STEEL PILES NOT SHOWN IN PLAN AND ELEVATION VIEWS FOR CLARITY° SEE "CORROSION PROTECTION FOR STEEL PILES DETAIL", SHEET 4 OF 10. 1'-0" To JT. 'Pe) 506.15 302.15 DM OF CAP WING 14 S1 & #4 S2 IYP. EACH END) DOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED STIRRUPS IN CAP MAY BE SHIFTED AS NECESSARY TO CLEAR DOWELS. THE CONCRETE IN THE SHADED AREA OF THE WING SHALL BE POURED AFTER THE VERTICAL CONCRETE BARRIER RAIL IS CAST IF SLIP FORMING IS USED. FOR PILE SPLICE DETAILS,SEE SHEET 4 OF 10. FOR WING DETAILS, SEE SHEET 3 OF 10. PROJECT NO. B-5323 GRANVILLE COUNTY STATION: SHEET 2 OF 10 14+66.00 -L- STD. NO. EB-36-9054 #4 K1 (EA. FACE) # n- O .. 2,_9„ g,_0„ PLAN OF WING( X #4 V1 BARS (EA. FACE) (SPACED AS SHOWN ABOVE) TOP OF WING (LEVEL) 0o , i i 0 i i CONST. JTe c - --- ----------------- --------------------------------- BOTTOM OF WING (LEVEL) x� ELEVATION OF WING( 3" HIGH B.B. Q 5'-O" CTS. 3„ G Q C7 a Ln 0 0 c-: U co w U a LL U a W # 0 WING DETAILS G Q U G a U) U co u� U co g,_0„ PLAN OF WING( 3" #4 V1 BARS (EA. FACE) (SPACED AS SHOWN ABOVE) TOP OF WING v (LEVEL) #4 K1 (EA. FACE) co � N # i 0 � CONST. JTo O co - ------------------------------------------------�- --- - i # o 3" HIGH B.B. Y 2 5'-0"CTS. ELEVATION OF WING( BOTTOM OF WING (LEVEL) DOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED LL a a # i�- #4 V1 -ILL FACE ONST. JTo 3" HIGH B.B. SECTION X-X 2" CLe 1 2" Cl #4 V1 DNST. JTo J F-11Ul-1 D.D. SECTION Y-Y PROJECT NOe B-5323 GRANVILLE COUNTY STATION: 14+66.00 -L- SHEET 3 OF 10 STD. NO. EB-36-9OS4 CV LO .. -04 -64 � w w a iq rr V) z w >_ 0 0 V)oD f* fol� fol� ff} ff} ff� MINIMUM OF 3- ONE CUBIC FOOT BAGS OF #78M STONE. BAGS SHALL BE OF POROUS FABRIC,SECURELY TIED. 6" ( MIN.) PIPE FOR DRAINAGE 6" ( MIN.) PIPE FOR DRAINAGE GRADE TO DRAIN GRADE TO DRAIN TOE OF SLOPE TOE OF SLOPE BAGGED STONE AND PIPE SHALL BE PLACED IMMEDIATELY AFTER COMPLETION OF END BENT EXCAVATION. PIPE MAY BE EITHER CONCRETE, CORRUGATED STEEL, CORRUGATED ALUMINUM ALLOY, OR CORRUGATED PLASTIC. PERFORATED PIPE WILL NOT BE ALLOWED. BAGGED STONE SHALL REMAIN IN PLACE UNTIL THE ENGINEER DIRECTS THAT IT BE REMOVED. THE CONTRACTOR SHALL REMOVE AND DISPOSE OF SILT ACCUMULATIONS AT BAGGED STONE WHEN SO DIRECTED BY THE ENGINEER. BAGS SHALL BE REMOVED AND REPLACED WHENEVER THE ENGINEER DETER- MINES THAT THEY HAVE DETERIORATED AND LOST THEIR EFFECTIVENESS. NO SEPARATE PAYMENT WILL BE MADE FOR THIS WORK AND THE ENTIRE COST OF THIS WORK SHALL BE INCLUDED IN THE UNIT CONTRACT PRICE BID FOR THE SEVERAL PAY ITEMS. TEMPORARY DRAINAGE AT END BENT C BEARING 1"X 8"X ELASTOMERI PAD (TYPE 7 CORED SLAB UNIT 2'-6" DETAIL "A" (END BENT No. 1 SHOWN, END BENT No. 2 SIMILAR BY ROTATION) FILL FACE (TYP. EACH PILE) PLAN BACK GOUGE DETAIL B BACK GOUGE DETAIL A 0 VPILE HORIZONTAL PILE VERTICAL 0 00 X o 0„ TO /8„ 0 �0 \ • o- \ 0 OR VERTICAL 600 +10 0 -0 ~ 0 " T O I/8 „ DETAIL A 0 0 DETAIL B POSITION OF PILE DURING WELDING. PILE SPLICE DETAILS Z CONCRETE COLLAR 14� HP 12 X bJ STEEL PILE 2'-0" ELEVATION CORROSION PROTECTION FOR STEEL PILES DETAIL (END BENT No. 1 SHOWN, END BENT No. 2 SIMILAR BY ROTATION) DRAWN BY: V. CHUNG DATE 10-18 CHECKED BY: E. PHELPS DATE II-18 DESIGN ENGINEER OF RECORD: D. RUGGLES DATE 12-18 BOTTOM OF CAP 1-#4 B2 EA. FACE BAR TYPES HKo (J)—D O HKo co O 4112„ 2,_5„ 411211 HK. ( 4 HKe \ O 1'-8" 2'-5" ALL BAR DIMENSIONS ARE OUT TO OUT. END BENT No. 1 END BENT No. 2 HP 12 X 53 STEEL PILES HP 12 X 53 STEEL PILES NO. 7 LIN. FT.= 175 NO. 7 LIN. FT.= 175 PILE DRIVING EQUIPMENT PILE DRIVING EQUIPMENT SETUP FOR SETUP FOR HP 12 X 53 STEEL PILES HP 12 X 53 STEEL PILES NO-7 NOo 7 1'-0" 11" 10" 11-71/2// #6 D1 DOWEL FILL SECTION A -A (CONCRETE COLLAR NOT SHOWN FOR CLARITY. SEE "CORROSION PROTECTION FOR STEEL PILES DETAIL.") BILL OF MATERIAL FOR ONE END BENT BAR N0. SIZE TYPE LENGTH WEIGHT B1 8 #9 1 44'-0" 1197 B2 28 #4 STR 22'-1" 413 B3 11 #4 STR 2'-5" 18 D1 24 #6 STR 1'-6" 54 H1 40 #4 2 9'-4" 249 K1 16 #4 STR 2'-11" 31 S1 56 #4 3 10'-5" 390 S2 56 #4 4 3'-2" 118 S3 28 #4 5 6'-6" 122 V1 52 #4 STR 6'-2" 214 REINFORCING STEEL (FOR ONE END BENT) 2,806 LBS. CLASS A CONCRETE BREAKDOWN (FOR ONE END BENT) POUR #1 CAP, LOWER PART 20.7 C.Y. OF WINGS & COLLARS POUR #2 UPPER PART OF 2.1 C.Y. WINGS TOTAL CLASS A CONCRETE 22.8 C.Y. PROJECT NOo B-5323 GRANVILLE COUNTY STATION- 14+66.00 -L- SHEET 4 OF 10 STATE OF NORTH CAROLINA DEPARTMENT OF TRANSPORTATION RALEIGH S U B S T R U C T U R E DOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED I E N D BENT No. 1& 2 Firm License No. C-1051 DETAILS 223 S. West St, Suite 1100 Raleigh, NC 27603 T 919.380.8750 www.stewartinc.com NO. BY: STEWART REVISIONS DATE: I N0. BY: I DATE: SHEET NO. S-18 TOTAL SHEETS 26 STD. NO. EB_30_90S4 sf:lffolYl NOTES STIRRUPS IN CAP MAY BE SHIFTED AS NECESSARY TO CLEAR DOWELS. c� N Lo .. -04 -64 � w w � a V) z w >- 0 0 V) o D f* fol� fol� BENT CONTROL LINE, C COLUMNS & DRILLED PIERS #4 U1 (TYPo EAe END) TOP OF CAP EL. 306.61 3—#4 U2 (TYPo EAo END) BOTTOM OF CAP EL. 303.61 PLAN WORKLINE SEE DETAIL 0 zi 4/1 3// 411 3/, 411 4„ CONST. JTo (TYPo) (TPP1) 5—#11 B1 (TYP.) COLUMN (TYPo) # (EACH BACE) 3" HIGH BoBo Cad 5'-0" CTS. * 6—#5 S1 3" * 9—#5 S1 * 7—#5 S1 *12—#5 S1 *12—#5 S1 * 7—#5 S1 * 9—#5 S1 3" * 6—#5 S1 C� 71/2" CTS. Cagy 3�/2" CTS. Cad 8" CTS. (a) 33/4" CTS. Cad 3%4" CTS. Cad 8" CTS. Cep 31/2" C71/2" CTS. PERMITTED TOP OF i CONST.JT. DRILLED PIER (TYPo) EL. 301.00 (TYPo) COLUMN & COLUMN & COLUMN & i DRILLED PIER Noo1 DRILLED PIER Noo2 DRILLED PIER N, 10—#11 M1 3' —0" 0 DRILLED PIER � SP-1 i (TYPo) i I I I APPROVED BAR SUPPORT (TYPo BOTTOM OF DRILLED PIER EA. M1 BAR) MIN. TIP EL. 273.00 (TYPo) 5'-3" 14'-0" 14'-0" 5'-3" 101-4 ELEVATION DIMENSIONS & REINFORCING STEEL ARE TYPICAL FOR EACH COLUMN & DRILLED PIER UNLESS OTHERWISE NOTED. SPAN B 17 SPAN A TOP OF CAP EL. 306.61 BOTTOM OF CAP EL. 303.61 D. 3 HOOKS ON "M" BARS MAY BE TURNED AS NECESSARY FOR PLACING REINFORCING STEEL. FOR DRILLED PIERS, SEE SECTION 411 OF THE STANDARD SPECIFICATIONS. ALL STEEL IN THE DRILLED PIERS IS INCLUDED IN THE PAY ITEMS FOR "REINFORCING STEEL" AND "SPIRAL COLUMN REINFORCING STEEL." * INVERT ALTERNATE STIRRUPS° THE LOCATION OF THE CONSTRUCTION JOINT IN THE DRILLED PIERS IS BASED ON AN APPROXIMATE GROUND LINE ELEVATION. IF THE CONSTRUCTION JOINT IS ABOVE THE ACTUAL GROUND LINE ELEVATION, THE CONTRACTOR SHALL PLACE THE CONSTRUCTION JOINT ONE FOOT BELOW THE GROUND LINE. DRILLED PIERS SHALL BE TERMINATED ONE FOOT ± ABOVE NORMAL WATER SURFACE ELEVATION FOR SHAFTS LOCATED IN WATER. THE CONTRACTOR'S ATTENTION IS CALLED TO THE FACT THAT THE LONGITUDINAL REINFORCEMENT FOR DRILLED PIERS IS DETAILED WITH 3 FEET OF EXTRA LENGTH. BENT CONTROL LINE 2'-1 ELAST01 PAD ( (� CORED SLAB UNIT 2'-6" I "0 U1 UVVVCLJ TO PROJECT 9" D E T A I L " A i i ABOVE CAP (TYPo) (DIMENSIONS ARE TYPICAL EACH BEARING) DOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED PROJECT NO. B-5323 GRANVILLE COUNTY STATION: SHEET 5 OF 10 14+66.00 -L- CV LO rd -04 -64 � w w � a iq rr V) z w >- 0 0 V)oD f* fol� fol� ff} ff} ff� 1( BENT 1 DR Q0 It PLAN OF DRILLED PIERS & COLUMNS BENT CONTROL LINE I END ELEVATION DRAWN BY: V. CHUNG DATE 10-18 CHECKED BY: E. PHELPS DATE 11-18 DESIGN ENGINEER OF RECORD: D. RUGGLES DATE 12-18 CD 0 I END OF CAP VIEW (TYPICAL BOTH ENDS) No. 3 #4 U2 'P. EA. END) HK. 1 HK. 1,_7„ 38,_0„ 1,_7„ #5 B2 (EACH FACE) #5 B2 (EACH FACE) #5 B2 (EACH FACE) 5-#11 B1 2'-10" _ Ln I N BAR TYPES 2'-6" U2 2'-8" U1 11/2 EXTRA TURNS INTO CAP U 0 11/2 EXTRA TURNS (�D BOTTOM OF DRILLED PIER 4 SPACERS ®r�� 2'-2'1 0 ALL BAR DIMENSIONS ARE OUT TO OUT 101, 9" 9" 10" I I 6 Y4„ 6 Y4„ I #6 D1 DOWELS N~ • • #5 i i i S1 I i I I I • • BENT CONTROL LINE I I 7 Y4 I 7 Y4 I � I I 111/4" SECTION THRU CAP 3/'HIGH B.B. BILL OF MATERIAL FOR ONE BENT BAR N0. SIZE TYPE LENGTH WEIGHT B1 10 #11 1 41'-2'1 2187 B2 6 #5 STR 38'-2" 239 D1 1 48 1 #6 1 STR 1 1'-6" 1 108 1 M1 1 30 I #11 1 4 1 36'-9" 1 5858 1 S1 1 68 I #5 1 2 1 9'-0'/ 1 638 1 U1 6 #4 3 5'-8" 1 23 U2 6 #4 3 5'-6" 22 REINFORCING STEEL (FOR ONE BENT) 9,075 LBS. SP-1 3 5 501'-0" 1568 SPIRAL COLUMN REINFORCING STEEL (FOR ONE BENT) 1,568 LBS. THE SP-1 SPIRAL REINFORCING STEEL SHALL BE W31 OR D-31 COLD DRAWN WIRE OR #5 PLAIN OR DEFORMED BAR CLASS A CONCRETE BREAKDOWN (FOR ONE BENT) POUR #2 (COLUMNS) 2.0 C.Y. POUR #3 (CAP) 13.6 C.Y. TOTAL CLASS A CONCRETE 15.6 C.Y. DRILLED PIERS-. (FOR ONE BENT) DRILLED PIER CONCRETE POUR #1 (DRILLED PIERS) 24.0 C.Y. 3'-0"0 DRILLED PIER NOT IN SOIL 45.0 LIN. FT. 3'-0"0 DRILLED PIER IN SOIL 46.8 LIN. FT. PERMANENT STEEL CASING FOR 3'-0/'0 DRILLED PIER 23.0 LIN. FT. CSL TUBES 385.3 LIN. FT. SID INSPECTIONS 1 EA. CSL TESTING 1 EA. PROJECT NOo B-5323 GRANVILLE COUNTY STATION: 14+66.00 -L- SHEET 6 OF 10 DOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED Firm License No. C-1051 223 S. West St, Suite 1100 7ol7l Raleigh, NC 27603 T 919.380.8750 www.stewartinc.com NO STEWART STATE OF NORTH CAROLINA DEPARTMENT OF TRANSPORTATION RALEIGH SUBSTRUCTURE BENT No.1 REVISIONS BY: I DATE: I N0. BY: I DATE: SHEET NO. S-20 TOTAL SHEETS 26 sf:lffolYl NOTES STIRRUPS IN CAP MAY BE SHIFTED AS NECESSARY TO CLEAR DOWELS. c� N Lo .. -04 -64 � w w � a V) z w >- 0 0 V) o D f* fol� fol� BENT CONTROL LINE, C COLUMNS & DRILLED PIERS #4 U1 (TYPo EAe END) TOP OF CAP EL. 306.48 3—#4 U2 (TYPo EAo END) BOTTOM OF CAP EL. 303.48 PLAN WORKLINE SEE DETAIL 0 zi 4/1 3// 411 3/, 411 4„ CONST. JTo (TYPo) (TPP1) 5—#11 B1 (TYP.) COLUMN (TYPo) # (EACH BACE) 3" HIGH BoBo Cad 5'-0" CTS. * 6—#5 S1 3" * 9—#5 S1 * 7—#5 S1 *12—#5 S1 *12—#5 S1 * 7—#5 S1 * 9—#5 S1 3" * 6—#5 S1 C� 71/2" CTS. Cagy 3�/2" CTS. Cad 8" CTS. (a) 33/4" CTS. Cad 3%4" CTS. Cad 8" CTS. Cep 31/2" C71/2" CTS. PERMITTED TOP OF i CONST.JT. DRILLED PIER (TYPo) EL. 301.00 (TYPo) COLUMN & COLUMN & COLUMN & i DRILLED PIER Noo1 DRILLED PIER Noo2 DRILLED PIER N, 10—#11 M1 3' —0" 0 DRILLED PIER � SP-1 i (TYPo) i I I I APPROVED BAR SUPPORT (TYPo BOTTOM OF DRILLED PIER EA. M1 BAR) MIN. TIP EL. 269.00 (TYPo) 5'-3" 14'-0" 14'-0" 5'-3" 101-4 ELEVATION DIMENSIONS & REINFORCING STEEL ARE TYPICAL FOR EACH COLUMN & DRILLED PIER UNLESS OTHERWISE NOTED. SPAN C 17 SPAN B TOP OF CAP EL. 306.48 BOTTOM OF CAP EL. 303.48 D. 3 HOOKS ON "M" BARS MAY BE TURNED AS NECESSARY FOR PLACING REINFORCING STEEL. FOR DRILLED PIERS, SEE SECTION 411 OF THE STANDARD SPECIFICATIONS. ALL STEEL IN THE DRILLED PIERS IS INCLUDED IN THE PAY ITEMS FOR "REINFORCING STEEL" AND "SPIRAL COLUMN REINFORCING STEEL." * INVERT ALTERNATE STIRRUPS° THE LOCATION OF THE CONSTRUCTION JOINT IN THE DRILLED PIERS IS BASED ON AN APPROXIMATE GROUND LINE ELEVATION. IF THE CONSTRUCTION JOINT IS ABOVE THE ACTUAL GROUND LINE ELEVATION, THE CONTRACTOR SHALL PLACE THE CONSTRUCTION JOINT ONE FOOT BELOW THE GROUND LINE. DRILLED PIERS SHALL BE TERMINATED ONE FOOT ± ABOVE NORMAL WATER SURFACE ELEVATION FOR SHAFTS LOCATED IN WATER. THE CONTRACTOR'S ATTENTION IS CALLED TO THE FACT THAT THE LONGITUDINAL REINFORCEMENT FOR DRILLED PIERS IS DETAILED WITH 3 FEET OF EXTRA LENGTH. BENT CONTROL LINE 2'-1 ELAST01 PAD ( (� CORED SLAB UNIT 2'-6" I "0 U1 UVVVCLJ TO PROJECT 9" D E T A I L " A i i ABOVE CAP (TYPo) (DIMENSIONS ARE TYPICAL EACH BEARING) DOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED PROJECT NO. B-5323 GRANVILLE COUNTY STATION: SHEET 7 OF 10 14+66.00 -L- CV LO rd -04 -64 � w w � a iq rr V) z w >- 0 0 V)oD f* fol� fol� ff} ff} ff� 1( BENT 1 DR Q0 It PLAN OF DRILLED PIERS & COLUMNS BENT CONTROL LINE I END ELEVATION DRAWN BY: V. CHUNG DATE 10-18 CHECKED BY: E. PHELPS DATE 11-18 DESIGN ENGINEER OF RECORD: D. RUGGLES DATE 12-18 CD 0 I END OF CAP VIEW (TYPICAL BOTH ENDS) No. 3 #4 U2 'P. EA. END) HK. 1 HK. 1,_7„ 38,_0„ 1,_7„ #5 B2 (EACH FACE) #5 B2 (EACH FACE) #5 B2 (EACH FACE) 5-#11 B1 2'-10" _ Ln I N BAR TYPES 2'-6" U2 2'-8" U1 HK. 3 4 1'-7" 39'-1" 11/2 EXTRA TURNS INTO CAP U F--I w I Ln 11/2 EXTRA TURNS (� BOTTOM OF DRILLED PIER 4 SPACERS ®r�� 2'-2'1 0 ALL BAR DIMENSIONS ARE OUT TO OUT 101, 9" 9" 10" I I 6 Y4„ 6 Y4„ I #6 D1 DOWELS N~ • • #5 i i i S1 I i I I I • • BENT CONTROL LINE I I 7 Y4 I 7 Y4 I � I I 111/4" SECTION THRU CAP 3/'HIGH B.B. BILL OF MATERIAL FOR ONE BENT BAR N0. SIZE TYPE LENGTH WEIGHT B1 10 #11 1 41'-2'1 2187 B2 6 #5 STR 38'-2" 239 D1 1 48 1 #6 1 STR 1 1'-6" 1 108 1 M1 1 30 I #11 1 4 1 40'-8" 1 6482 1 S1 1 68 I #5 1 2 1 9'-0'/ 1 638 1 U1 6 #4 3 5'-8" 1 23 U2 6 #4 3 5'-6" 22 REINFORCING STEEL (FOR ONE BENT) 9,699 LBS. SP-1 3 5 562'-10" 1761 SPIRAL COLUMN REINFORCING STEEL (FOR ONE BENT) 1,761 LBS. THE SP-1 SPIRAL REINFORCING STEEL SHALL BE W31 OR D-31 COLD DRAWN WIRE OR #5 PLAIN OR DEFORMED BAR CLASS A CONCRETE BREAKDOWN (FOR ONE BENT) POUR #2 (COLUMNS) 1.9 C.Y. POUR #3 (CAP) 13.6 C.Y. TOTAL CLASS A CONCRETE 15.5 C.Y. DRILLED PIERS-. (FOR ONE BENT) DRILLED PIER CONCRETE POUR #1 (DRILLED PIERS) 27.1 C.Y. 3'-0"0 DRILLED PIER NOT IN SOIL 45.0 LIN.FT. 3'-0"0 DRILLED PIER IN SOIL 58.4 LIN. FT. PERMANENT STEEL CASING FOR 3'-0/'0 DRILLED PIER 26.0 LIN. FT. CSL TUBES 431.8 LIN. FT. SID INSPECTIONS 1 EA. CSL TESTING 1 EA. PROJECT NOo B-5323 GRANVILLE COUNTY STATION: 14+66.00 -L- SHEET 8 OF 10 DOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED Firm License No. C-1051 223 S. West St, Suite 1100 7ol7l Raleigh, NC 27603 T 919.380.8750 www.stewartinc.com NO STEWART STATE OF NORTH CAROLINA DEPARTMENT OF TRANSPORTATION RALEIGH SUBSTRUCTURE BENT No.2 REVISIONS BY: I DATE: I N0. BY: I DATE: SHEET NO. 5-22 TOTAL SHEETS 26 sf:lffolYl NOTES STIRRUPS IN CAP MAY BE SHIFTED AS NECESSARY TO CLEAR DOWELS. c� N Lo .. -04 -64 � w w � a V) z w >- 0 0 V) o D f* fol� fol� BENT CONTROL LINE, C COLUMNS & DRILLED PIERS #4 U1 (TYPo EAe END) TOP OF CAP EL. 306.31 3—#4 U2 (TYPo EAo END) BOTTOM OF CAP EL. 303.31 PLAN WORKLINE SEE DETAIL 0 zi 4/1 3// 411 3/, 411 4„ CONST. JTo (TYPo) (TPP1) 5—#11 B1 (TYP.) COLUMN (TYPo) # (EACH BACE) 3" HIGH BoBo Cad 5'-0" CTS. * 6—#5 S1 3" * 9—#5 S1 * 7—#5 S1 *12—#5 S1 *12—#5 S1 * 7—#5 S1 * 9—#5 S1 3" * 6—#5 S1 C� 71/2" CTS. Cagy 3�/2" CTS. Cad 8" CTS. (a) 33/4" CTS. Cad 3%4" CTS. Cad 8" CTS. Cep 31/2" C71/2" CTS. PERMITTED TOP OF i CONST.JT. DRILLED PIER (TYPo) EL. 301.00 (TYPo) COLUMN & COLUMN & COLUMN & i DRILLED PIER Noo1 DRILLED PIER Noo2 DRILLED PIER N, 10—#11 M1 3' —0" 0 DRILLED PIER � SP-1 i (TYPo) i I I I APPROVED BAR SUPPORT (TYPo BOTTOM OF DRILLED PIER EA. M1 BAR) MIN. TIP EL. 275.00 (TYPo) 5'-3" 14'-0" 14'-0" 5'-3" 101-4 ELEVATION DIMENSIONS & REINFORCING STEEL ARE TYPICAL FOR EACH COLUMN & DRILLED PIER UNLESS OTHERWISE NOTED. SPAN D 17 SPAN C TOP OF CAP EL. 306.31 BOTTOM OF CAP EL. 303.31 D. 3 HOOKS ON "M" BARS MAY BE TURNED AS NECESSARY FOR PLACING REINFORCING STEEL. FOR DRILLED PIERS, SEE SECTION 411 OF THE STANDARD SPECIFICATIONS. ALL STEEL IN THE DRILLED PIERS IS INCLUDED IN THE PAY ITEMS FOR "REINFORCING STEEL" AND "SPIRAL COLUMN REINFORCING STEEL." INVERT ALTERNATE STIRRUPS° THE LOCATION OF THE CONSTRUCTION JOINT IN THE DRILLED PIERS IS BASED ON AN APPROXIMATE GROUND LINE ELEVATION. IF THE CONSTRUCTION JOINT IS ABOVE THE ACTUAL GROUND LINE ELEVATION, THE CONTRACTOR SHALL PLACE THE CONSTRUCTION JOINT ONE FOOT BELOW THE GROUND LINE. DRILLED PIERS SHALL BE TERMINATED ONE FOOT ± ABOVE NORMAL WATER SURFACE ELEVATION FOR SHAFTS LOCATED IN WATER. THE CONTRACTOR'S ATTENTION IS CALLED TO THE FACT THAT THE LONGITUDINAL REINFORCEMENT FOR DRILLED PIERS IS DETAILED WITH 3 FEET OF EXTRA LENGTH. BENT CONTROL LINE 2'-1 ELAST01 PAD ( (� CORED SLAB UNIT 2'-6" I "0 U1 UVVVCLJ TO PROJECT 9" D E T A I L " A i i ABOVE CAP (TYPo) (DIMENSIONS ARE TYPICAL EACH BEARING) DOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED PROJECT NO. B-5323 GRANVILLE COUNTY STATION: SHEET 9 OF 10 14+66.00 -L- CV LO rd -04 -64 � w w � a iq rr V) z w >- 0 0 V)oD f* fol� fol� ff} ff} ff� 1( BENT 1 DR Q0 It PLAN OF DRILLED PIERS & COLUMNS BENT CONTROL LINE I END ELEVATION DRAWN BY: V. CHUNG DATE 10-18 CHECKED BY: E. PHELPS DATE 11-18 DESIGN ENGINEER OF RECORD: D. RUGGLES DATE 12-18 CD 0 I END OF CAP VIEW (TYPICAL BOTH ENDS) No. 3 #4 U2 'P. EA. END) HK. 1 HK. 1,_7„ 38,_0„ 1,_7„ #5 B2 (EACH FACE) #5 B2 (EACH FACE) #5 B2 (EACH FACE) 5-#11 B1 2'-10" _ Ln I N BAR TYPES 2'-6" U2 2'-8" U1 11/2 EXTRA TURNS INTO CAP U H 5 w Ln CV 11/2 EXTRA TURNS (�D I BOTTOM OF DRILLED PIER 4 SPACERS 2'-2'1 0 ALL BAR DIMENSIONS ARE OUT TO OUT 101, 9" 9" 10" I I 6 Y4„ 6 Y4„ I #6 D1 DOWELS N~ • • #5 i i i S1 I i I I I • • BENT CONTROL LINE I I 7 Y4 I 7 Y4 I � I I 111/4" SECTION THRU CAP 3/'HIGH B.B. BILL OF MATERIAL FOR ONE BENT BAR N0. SIZE TYPE LENGTH WEIGHT B1 10 #11 1 41'-2'1 2187 B2 6 #5 STR 38'-2" 239 D1 1 48 1 #6 1 STR 1 1'-6" 1 108 1 M1 1 30 I #11 1 4 1 34'-6" 1 5499 1 S1 1 68 I #5 1 2 1 9'-0'/ 1 638 1 U1 6 #4 3 5'-8" 1 23 U2 6 #4 3 5'-6" 22 REINFORCING STEEL (FOR ONE BENT) 8,716 LBS. SP-1 3 5 464'-3" 1453 SPIRAL COLUMN REINFORCING STEEL (FOR ONE BENT) 1453 LBS. THE SP-1 SPIRAL REINFORCING STEEL SHALL BE W31 OR D-31 COLD DRAWN WIRE OR #5 PLAIN OR DEFORMED BAR CLASS A CONCRETE BREAKDOWN (FOR ONE BENT) POUR #2 (COLUMNS) 1.8 C.Y. POUR #3 (CAP) 13.6 C.Y. TOTAL CLASS A CONCRETE 15.4 C.Y. DRILLED PIERS-. (FOR ONE BENT) DRILLED PIER CONCRETE POUR #1 (DRILLED PIERS) 22.2 C.Y. 3'-0"0 DRILLED PIER NOT IN SOIL 15.0 LIN. FT. 3'-0"0 DRILLED PIER IN SOIL 69.9 LIN. FT. PERMANENT STEEL CASING FOR 3'-0/'0 DRILLED PIER 23.0 LIN. FT. CSL TUBES 357.7 LIN. FT. SID INSPECTIONS 1 EA. CSL TESTING 1 EA. PROJECT NOo B-5323 GRANVILLE COUNTY STATION: 14+66.00 -L- SHEET 10 OF 10 DOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED Firm License No. C-1051 223 S. West St, Suite 1100 7ol7l Raleigh, NC 27603 T 919.380.8750 www.stewartinc.com NO STEWART STATE OF NORTH CAROLINA DEPARTMENT OF TRANSPORTATION RALEIGH SUBSTRUCTURE BENT No.3 REVISIONS BY: I DATE: I N0. BY: I DATE: SHEET NO. 5-24 TOTAL SHEETS 26 N L� wd -Gq fb�_ � w w � Q cn z w c-D cn o z END BENT NOo 1 20'-0" C SHOULDER LINE BRIDGE AND ROADWAY SHOULDER LINE FI 707 7F 1'-0/' MIN. EARTH BERM NORMAL TO CAP EL. 303.75 END BENT NOo 1 1'-7" MIN. BERM SHOULDER LINE NORMAL TO CAP DO O r- o EL. 303.75 Cad EB#1 15 C, EB#2 1'-0" MIN. EARTH BER NORMAL TO CAP GEOTEXTILE SECTION H-H SLOPE 11/2.1 PLAN OF RIP RAP 1'-7" MIN. BERM NORMAL TO CAP r---- i o i i EL. 303.75 2 EB#1 ELo 303.15 Q EB#2 —�--�— SLOPE 11/2e 1 2'-0" , GROUND LINE 1'-0" MIN° EARTH BERM NORMAL TO CAP 0 r1,l GEOTEXTILE — � SECTION BERM RIP RAPPED GROUND LINE END BENT NOo 2 10'-0" C 1� O� 9�1 O � END BENT NO.2 SHOULCrn SECTION C-C A \Y NOTES FOR BERM WIDTH DIMENSIONS, SEE GENERAL DRAWING. LINE =I LINE ESTIMATED QUANTITIES BRIDGE Cad RIP RAP GEOTEXTILE STA.14+66.00 —L— CLASS II FOR DRAINAGE (2'-0'/ THICK) TONS SQUARE YARDS END BENT 1 440 485 END BENT 2 400 440 GROUND LINE �o z i H DOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED PROJECT NOe B-5323 GRANVILLE COUNTY STATION: 14+66.00 -L- STD. NO. RR1 (Sht 2) NOTES cn N cn Lo .. m rr 00--) U �I 6" BEVEL 12'-0" 6' 1'-3"lm 11-#4A1 Cad 1'-O" CTS, � (TOP OF SLAB) (2 BAR RUN) m 1'-3" i 11-#4A2 (� 1'-O" CTS, m a (BOTTOM OF SLAB) (2 BAR RUN)' a cn i J u� m i i a � 0 BEGIN ' 3: 0 APPROACH SLAB 0 0 0 ~ o ' N m ' Al i a w J o U Q9 u 3 „ @ in # N m 91,i o Q # o r- i i i i FILL FACE Cad END BENT #1 #4A2 (BOTT, OF ' SLAB) i #4A1 i (TOP OF ' SLAB) � N ' m 0 0 PROPOSED ASPHALT PAVEMENT PLAN N Q END 51/4" CONTINUOUS HIGH CHAIR UPPER (CHCU) 2 3'-0" CTS. ACROSS SLAB #5B1 i 7-7 ROADWAY- J c.�\#4A2 #6B2 APPROVED WIRE BAR SUPPORTS 2 3'-0" CTS. BENT #1 N PLAN 2 END BENT #2 DIMENSIONS SHOWN ARE TYPICAL FOR BOTH APPROACH SLABS APPROXIMATE 10 1 SLOPE (TO BE DETERMINED BY THE CONTRACTOR) t NORMAL TO END BENT 4"0 PERFORATED SCHEDULE 40 PVC PIPE #4A1 J u N t2 0 1 SLOPE SELECT MATERIAL (CLASS V OR CLASS VI)-7 GEOTEXTILE o 0L 0 '' 0o0 SECTION THRU SLAB (TYPE II — MODIFIED APPROACH FILL) t 1 /-11/2„ 1 00 Z I " CORED SLAB 7 \--11/2" BACKER ROD I 2 LAYERS OF 30 LB. ROOFING FELT TO PREVENT BOND 8„ z CV H 4 SECTION N-N FOR BRIDGE APPROACH FILL INCLUDING GEOTEXTILE, 4"0 DRAINAGE PIPE, AND SELECT MATERIAL BACKFILL, SEE ROADWAY PLANS. GEOTEXTILE SHALL BE TYPE 1 IN ACCORDANCE WITH THE STANDARD SPECIFICATIONS SECTION 1056. SELECT MATERIAL BACKFILL (CLASS V OR CLASS VT) SHALL BE IN ACCORDANCE WITH STANDARD SPECIFICATIONS SECTION 1016. SELECT MATERIAL BACKFILL IS TO BE CONTINUOUS ALONG FILL FACE OF BACKWALL FROM OUTSIDE EDGE TO OUTSIDE EDGE OF APPROACH SLAB. FOR THE 4" 0 DRAINAGE PIPE OUTLET(S), SEE ROADWAY STANDARD DRAWINGS° AREA BETWEEN THE WINGWALL AND APPROACH SLAB SHALL BE GRADED TO DRAIN THE WATER AWAY FROM THE FILL FACE OF THE BRIDGE AND SHALL BE PAVED.SEE ROADWAY PLANS. a BRIDGE DECK oQ�' Ln Lj- 0 m VV F� CAP FLOW LINE ONLY WITH EROSION RESISTANT MATERIAL --'--� BACKFILL EXCAVATION HOLE @ AND GRADE TO DRAIN m NOTE: IF THE APPROACH SLAB IS NOT CONSTRUCTED IMMEDIATELY Lo # AFTER THE BACKFILLING OF THE END BENT EXCAVATION, GRADE TO DRAIN TO THE BOTTOM OF THE SLOPE AND PROVIDE EROSION RESISTANT MATERIAL, SUCH AS FIBERGLASS ROVING OR AS DIRECTED BY THE ENGINEER TO PREVENT SOIL EROSION AND TO PROTECT THE AREA ADJACENT TO THE STRUCTURE, THE CONTRACTOR WILL BE REQUIRED TO REMOVE THESE MATERIALS PRIOR TO CONSTRUCTION OF THE APPROACH SLAB. TEMPORARY DRAINAGE DETAIL CLASS "B" STONE o FOR EROSION CONTROL s TEMP,SLOPE DRAIN 2'-0"MIN, EARTH DITCH BLOCK APPROACH SLAB 1'-0" "N.FUTURE SHOULDER �\0 z H iE GR p.0 ZPE � S* N ,—, R +J c� FLOW LINE END OF ® EROSION RESISTANT MATERIAL APPROACH SLAB 1'-6"MIN. NOTE: IMMEDIATELY AFTER THE CONSTRUCTION OF THE APPROACH SLAB, THE CONTRACTOR SHALL PROVIDE TEMPORARY BERM AND SLOPE DRAIN. CONTRACTOR SHALL GRADE TO PIPE INLET AND PROVIDE EROSION RESISTANT MATERIAL AS SHOWN. THE EROSION RESISTANT MATERIAL SHALL BE EITHER 1)ASPHALT PLANT MIX, TYPE 1 OR TYPE 2, MINe 2" DEPTH, 2) EROSION CONTROL MAT, OR 3) CONCRETE, AS DIRECTED BY THE ENGINEER° THE SLOPE DRAIN SHALL CONSIST OF A NON -PERFORATED TEMPORARY DRAINAGE PIPE,12 INCHES IN DIAMETER. PLAN VIEW r� 3 1 ��2 ►; END OF CURB WITHOUT SHOULDER BERM GUTTER CURB DETAILS SPICE LENGTHS BAR SIZE EPDXY COATED UNCOATED #5 2,_6„ 21_211 #6 Y-10// 2'-7" ELBOW TEMPORARY SLOPE DRAIN ELBOW TOE OF FILL' CLASS "B"STONE FOR EROSION CONTROL SECTION R-R 3"EROSION RESISTANT 12"MINe MATERIAL OVER PIPE EARTH DITCH BLOCK N --T--r—------- FILL SLOPE SECTION S-S TEMPORARY BERM AND SLOPE DRAIN DETAILS (TO BE USED WHEN SHOULDER BERM GUTTER IS REQUIRED) DOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED PROJECT NO. B-5323 GRANVILLE STATION: COUNTY 14+66.00 -L- STD. NO. BAS-36-90S c� N Lo 'fig -04 {f} -64 {f} {f} w W � a V) z w 0 0 � o � DESIGN DATA-. SPECIFICATIONS — — — — — — — — — — — — — — — — — A.A.S.H.T.O. (CURRENT) LIVE LOAD — — — — — — — — — — — — — — — — — — — — SEE PLANS IMPACT ALLOWANCE — — — — — — — — — — — — — — — — SEE A.A.S.H.T.O. STRESS IN EXTREME FIBER OF STRUCTURAL STEEL — AASHTO M27O GRADE 36 — — 209000 LBS. PER SO. INo — AASHTO M27O GRADE 5OW — — 27,000 LBS. PER SO. IN. — AASHTO M27O GRADE 50 — — 27,000 LBS. PER SO. INo REINFORCING STEEL IN TENSION — GRADE 60 — — — 24,000 LBS. PER SO. INo CONCRETE IN COMPRESSION — — — — — — — — — — — — 1,200 LBS. PER SQ. IN. CONCRETE IN SHEAR — — — — — — — — — — — — — — — — SEE A.A.S.H.T.O. STRUCTURAL TIMBER — TREATED OR UNTREATED EXTREME FIBER STRESS — — — 1,800 LBS. PER SO.IN. COMPRESSION PERPENDICULAR TO GRAIN OF TIMBER — — — — — 375 LBS. PER SO. INo EQUIVALENT FLUID PRESSURE OF EARTH — — — — — 30 LBS. PER CU. FT. (MINIMUM) MATERIAL AND WORKMANSHIP-. EXCEPT AS MAY OTHERWISE BE SPECIFIED ON PLANS OR IN THE SPECIAL PROVISIONS, ALL MATERIAL AND WORKMANSHIP SHALL BE IN ACCORDANCE WITH THE 2018 "STANDARD SPECIFICATIONS FOR ROADS AND STRUCTURES"OF THE N.C.DEPARTMENT OF TRANSPORTATION. STEEL SHEET PILING FOR PERMANENT OR TEMPORARY APPLICATIONS SHALL BE HOT ROLLED. CONCRETE-. UNLESS OTHERWISE REQUIRED ON PLANS,CLASS A CONCRETE SHALL BE USED FOR ALL PORTIONS OF ALL STRUCTURES WITH THE EXCEPTION THAT: CLASS AA CONCRETE SHALL BE USED IN BRIDGE SUPERSTRUCTURES, ABUTMENT BACKWALLS,AND APPROACH SLABS,AND CLASS B CONCRETE SHALL BE USED FOR SLOPE PROTECTION AND RIP RAP. CONCRETE CHAMFERS -.- UNLESS OTHERWISE NOTED ON THE PLANS,ALL EXPOSED CORNERS ON STRUCTURES SHALL BE CHAMFERED 3/4"WITH THE FOLLOWING EXCEPTIONS: TOP CORNERS OF CURBS MAY BE ROUNDED TO 11/2"RADIUS WHICH IS BUILT INTO CURB FORMS, CORNERS OF TRANSVERSE FLOOR EXPANSION JOINTS SHALL BE ROUNDED WITH A 1/4"FINISHING TOOL UNLESS OTHERWISE REQUIRED ON PLANS,AND CORNERS OF EXPANSION JOINTS IN THE ROADWAY FACES AND TOPS OF CURBS AND SIDEWALKS SHALL BE ROUNDED TO A 1/4"RADIUS WITH A FINISHING STONE OR TOOL UNLESS OTHERWISE REQUIRED ON PLANS. DOWELS -.- DOWELS WHEN INDICATED ON PLANS AS FOR CULVERT EXTENSIONS,SHALL BE EMBEDDED AT LEAST 12"INTO THE OLD CONCRETE AND GROUTED INTO PLACE WITH 1:2 CEMENT MORTAR. STANDARD NOTES ALLOWANCE FOR DEAD LOAD DEFLECTION, SETTLEMENTS ETC. IN CASTING SUPERSTRUCTURES-. BRIDGES SHALL BE BUILT ON THE GRADE OR VERTICAL CURVE SHOWN ON PLANS. SLABS, CURBS AND PARAPETS SHALL CONFORM TO THE GRADE OR CURVE. ALL DIMENSIONS WHICH ARE GIVEN IN SECTION AND ARE AFFECTED BY DEAD LOAD DEFLECTIONS ARE DIMENSIONS AT CENTER LINE OF BEARING UNLESS OTHERWISE NOTED ON PLANS. IN SETTING FORMS FOR STEEL BEAM BRIDGES AND PRESTRESSED CONCRETE GIRDER BRIDGES, ADJUSTMENTS SHALL BE MADE DUE TO THE DEAD LOAD DEFLECTIONS FOR THE ELEVATIONS SHOWN. WHERE BLOCKS ARE SHOWN OVER BEAMS FOR BUILDING UP TO THE SLAB,THE VERTICAL DIMENSIONS OF THE BLOCKS SHALL BE ADJUSTED BETWEEN BEARINGS TO COMPENSATE FOR DEAD LOAD DEFLECT TONS, VERTICAL CURVE ORDINATE,AND ACTUAL BEAM CAMBER. WHERE BOTTOM OF SLAB IS IN LINE WITH BOTTOM OF TOP FLANGES,DEPTH OF SLAB BETWEEN BEARINGS SHALL BE ADJUSTED TO COMPENSATE FOR DEAD LOAD DEFLECTION,VERTICAL CURVE ORDINATE,AND ACTUAL BEAM CAMBER. IN SETTING FALSEWORK AND FORMS FOR REINFORCED CONCRETE SPANS, AN ALLOWANCE SHALL BE MADE FOR DEAD LOAD DEFLECTIONS, SETTLEMENT OF FALSEWORK, AND PERMANENT CAMBER WHICH SHALL BE PROVIDED FOR IN ADDITION TO THE ELEVATIONS SHOWN. AFTER REMOVAL OF THE FALSEWORK,THE FINISHED STRUCTURES SHALL CONFORM TO THE PROFILE AND ELEVATIONS SHOWN ON THE PLANS AND CONSTRUCTION ELEVATIONS FURNISHED BY THE ENGINEER. DETAILED DRAWINGS FOR FALSEWORK OR FORMS FOR BRIDGE SUPERSTRUCTURE AND ANY STRUCTURE OR PARTS OF A STRUCTURE AS NOTED ON THE PLANS SHALL BE SUBMITTED TO THE ENGINEER FOR APPROVAL BEFORE CONSTRUCTION OF THE FALSEWORK OR FORMS IS STARTED. REINFORCING STEEL-, ALL REINFORCING STEEL SHALL BE DEFORMED. DIMENSIONS RELATIVE TO PLACEMENT OF REINFORCING ARE TO CENTERS OF BARS UNLESS OTHERWISE INDICATED IN THE PLANS. DIMENSIONS ON BAR DETAILS ARE TO CENTERS OF BARS OR ARE OUT TO OUT AS INDICATED ON PLANS. WIRE BAR SUPPORTS SHALL BE PROVIDED FOR REINFORCING STEEL WHERE INDICATED ON THE PLANS. WHEN BAR SUPPORT PIECES ARE PLACED IN CONTINUOUS LINES, THEY SHALL BE SO PLACED THAT THE ENDS OF THE SUPPORTING WIRES SHALL BE LAPPED TO LOCK LEGS ON ADJOINING PIECES. STRUCTURAL STEEL -. AT THE CONTRACTOR'S OPTION, HE MAY SUBSTITUTE %"0 SHEAR STUDS FOR THE 3/4"O STUDS SPECIFIED ON THE PLANS. THIS SUBSTITUTION SHALL BE MADE AT THE RATE OF 3 — 7/8" 0 STUDS FOR 4 — %4" 0 STUDS, AND STUD SPACING CHANGES SHALL BE MADE AS NECESSARY TO PROVIDE THE SAME EQUIVALENT NUMBER OF 7/8"0 STUDS ALONG THE BEAM AS SHOWN FOR 3/4" O STUDS BASED ON THE RATIO OF 3 — 7/8" 0 STUDS FOR 4 — 3/4" O STUDS. STUDS OF THE LENGTH SPECIFIED ON THE PLANS MUST BE PROVIDED. THE MAXIMUM SPACING SHALL BE 2'-0". EXCEPT AT THE INTERIOR SUPPORTS OF CONTINUOUS BEAMS WHERE THE COVER PLATE IS IN CONTACT WITH BEARING PLATE, THE CONTRACTOR MAY, AT HIS OPTION, SUBSTITUTE FOR THE COVER PLATES DESIGNATED ON THE PLANS COVER PLATES OF THE EQUIVALENT AREA PROVIDED THESE PLATES ARE AT LEAST 5/6"IN THICKNESS AND DO NOT EXCEED A WIDTH EQUAL TO THE FLANGE WIDTH LESS 2"OR A THICKNESS EQUAL TO 2 TIMES THE FLANGE THICKNESS. THE SIZE OF FILLET WELDS SHALL CONFORM TO THE REQUIREMENTS OF THE CURRENT ANSI/AASHTO/AWS "BRIDGE WELDING CODE". ELECTROSLAG WELDING WILL NOT BE PERMITTED. WITH THE SOLE EXCEPTION OF EDGES AT SURFACES WHICH BEAR ON OTHER SURFACES,ALL SHARP EDGES AND ENDS OF SHAPES AND PLATES SHALL BE SLIGHTLY ROUNDED BY SUITABLE MEANS TO A RADIUS OF APPROXIMATELY 1/16INCH OR EQUIVALENT FLAT SURFACE AT A SUITABLE ANGLE PRIOR TO PAINTING, GALVANIZING, OR METALLIZING. HANDRAILS AND POSTS-. METAL STANDARDS AND FACES OF THE CONCRETE END POSTS FOR THE METAL RAIL SHALL BE SET NORMAL TO THE GRADE OF THE CURB, UNLESS OTHERWISE SHOWN ON PLANS. THE METAL RAIL AND TOPS OF CONCRETE POSTS USED WITH THE ALUMINUM RAIL SHALL BE BUILT PARALLEL TO THE GRADE OF THE CURB. METAL HANDRAILS SHALL BE IN ACCORDANCE WITH THE PLANS. RAILS SHALL BE AS MANUFACTURED FOR BRIDGE RAILING. CASTINGS SHALL BE OF A UNIFORM APPEARANCE. FINS AND OTHER DEFORMATIONS RESULTING FROM CASTING OR OTHERWISE SHALL BE REMOVED IN A MANNER SO THAT A UNIFORM COLORING OF THE COMPLETED CASTING SHALL BE OBTAINED. CASTINGS WITH DISCOLORATIONS OR OF NON —UNIFORM COLORING WILL NOT BE ACCEPTED. CERTIFIED MILL REPORTS ARE REQUIRED FOR METAL RAILS AND POSTS. SPECIAL NOTES-, GENERALLY, IN CASE OF DISCREPANCY, THIS STANDARD SHEET OF NOTES SHALL GOVERN OVER THE SPECIFICATIONS, BUT THE REMAINDER OF THE PLANS SHALL GOVERN OVER NOTES HEREON, AND SPECIAL PROVISIONS SHALL GOVERN OVER ALL. SEE SPECIFICATIONS ARTICLE 105-4. REV. 6-16-95 ELM (✓) R G W REV. 5-7-03 RWW J T E REV. 10-1-11 MAA (✓) GM REV. 8-16-99 RWW (✓) L E S REV. 5-1-06 TLA GM REV. 12-17 MAA T H C STD. NO. SN