Loading...
HomeMy WebLinkAboutWQ0001861_Compliance Evaluation Inspection_20191028Compliance Inspection Report Permit: WQ0001861 Effective: 10/03/14 Expiration: 09/30/19 owner: Gregory Poole Equipment Company SOC: Effective: Expiration: Facility: Leland Facility County: Brunswick 151 Backhoe Rd Region: Wilmington Leland NC 28451 Contact Person: Ronnie Vaughn Title: Phone: 919-890-4629 Directions to Facility: System Classifications: Primary ORC: Secondary ORC(s): On -Site Representative(s): Related Permits: Inspection Date: 10/22/2019 Primary Inspector: Geoff Kegley Secondary Inspector(s): Entry Time: 01:OOPM Reason for Inspection: Routine Permit Inspection Type: Closed -Loop Recycle Facility Status: Compliant Not Compliant Question Areas: Miscellaneous Questions Treatment Storage Wells (See attachment summary) Certification: Phone: Exit Time: 02:OOPM Phone: Inspection Type: Compliance Evaluation Record Keeping Page 1 of 5 Permit: WQ0001861 Owner - Facility: Gregory Poole Equipment Company Inspection Date: 10/22/2019 Inspection Type : Compliance Evaluation Reason for Visit: Routine Inspection Summary: Holding pond has not been in use in many years and according to the operations staff is disconnected and is not needed. Freeboard records are still being maintained. Pond appears in need of maintenance if put back in service (vegetative growth inside pond and inside berms). If this pond is in fact unnecessary for operations at the facility, it is recommended that the pond be properly closed out and a permit modification request is applied for to remove it from the permit. Records of residuals removal and disposal were provided after inspection. Soil Recovery, Inc. (Sam Long) is the disposal contractor. The groundwater monitoring well sampling data is being submitted and no exceedances of the standards have been reported. However, the reporting of Total Dissolved Solids (TDS) on the GW-59 form is being reported in micrograms per Liter (ug/L) and the form calls for milligrams per Liter (mg/L). Data entry staff in Raleigh are entering the values reported as mg/L and therefore triggering limit violations in our system. This reporting issue was discussed during the inspection and should be corrected on future reporting forms. Page 2 of 5 Permit: WQ0001861 Inspection Date: 10/22/2019 Owner - Facility: Gregory Poole Equipment Company Inspection Type : Compliance Evaluation Reason for Visit: Routine Type Yes No NA NE Reuse (Quality) ❑ Recycle/Reuse ❑ Single Family Spray, LR ❑ Activated Sludge Spray, HR ❑ Activated Sludge Drip, LR ❑ Lagoon Spray, LR ❑ Activated Sludge Spray, LR ❑ Single Family Drip ❑ Infiltration System ❑ Treatment Yes No NA NE Are Treatment facilities consistent with those outlined in the current permit? 0 ❑ ❑ ❑ Do all treatment units appear to be operational? (if no, note below.) ❑ 0 ❑ ❑ Comment: Holding pond has been reportedly disconnected and has not been used in many years. Record Keeping Yes No NA NE Is a copy of current permit available? ❑ ❑ ❑ Are monitoring reports present: NDMR? ❑ ❑ 0 ❑ NDAR? ❑ ❑ 0 ❑ Are flow rates less than of permitted flow? ❑ ❑ ❑ Are flow rates less than of permitted flow? ❑ ❑ ❑ Are application rates adhered to? ❑ ❑ ❑ Is GW monitoring being conducted, if required (GW-59s submitted)? ❑ ❑ ❑ Are all samples analyzed for all required parameters? ❑ ❑ ❑ Are there any 2L GW quality violations? ❑ ❑ ❑ Is GW-59A certification form completed for facility? ❑ ❑ ❑ Is effluent sampled for same parameters as GW? ❑ ❑ ❑ Do effluent concentrations exceed GW standards? ❑ ❑ ❑ Are annual soil reports available? ❑ ❑ ❑ # Are PAN records required? ❑ ❑ ❑ # Did last soil report indicate a need for lime? ❑ ❑ ❑ If so, has it been applied? ❑ ❑ ❑ Are operational logs present? ❑ ❑ ❑ Are lab sheets available for review? ❑ ❑ ❑ Do lab sheets support data reported on NDMR? ❑ ❑ ❑ Do lab sheets support data reported on GW-59s? ❑ ❑ ❑ Page 3 of 5 Permit: WQ0001861 Owner - Facility: Gregory Poole Equipment Company Inspection Date: 10/22/2019 Inspection Type : Compliance Evaluation Reason for Visit: Routine Are Operational and Maintenance records present? ❑ ❑ ❑ Were Operational and Maintenance records complete? ❑ ❑ ❑ Has permittee been free of public complaints in last 12 months? ❑ ❑ ❑ Is a copy of the SOC readily available? ❑ ❑ ❑ No treatment units bypassed since last inspection? ❑ ❑ 0 ❑ Comment: See inspection summary ST-1 Storage Yes No NA NE Storage Type? Pond Storage amount? 0.17 Acres # At what point is side -stream wastewater returned to treatment? Is there a Spill Control Plan? ❑ ❑ ❑ Aerated or Mixed? NONE If aeration is present, is it adequate? ❑ ❑ ❑ If present, are diffusers cleaned regularly? ❑ ❑ ❑ Is influent structure acceptable? ❑ ❑ 0 ❑ Are banks/berms free of seepage and erosion? 0 ❑ ❑ ❑ Are banks/berms free of excessive vegetation? ❑ 0 ❑ ❑ Is pond lined? 0 ❑ ❑ ❑ Liner Type Full, clay Is liner acceptable? ❑ ❑ ❑ Are baffles/curtains acceptable? ❑ ❑ 0 ❑ Does the pond have a freeboard marker? 0 ❑ ❑ ❑ Required freeboard? 2 Feet Actual freeboard? 5 Feet Is there suitable grassed vegetation? ❑ ❑ ❑ Is the vegetation maintained? ❑ ❑ ❑ Is the area free of excessive weeds and/or woody species? ❑ ❑ ❑ Is the area free from signs of overflow? ❑ ❑ ❑ Is color acceptable? ❑ ❑ ❑ Are floating mats acceptable? ❑ ❑ ❑ No excessive buildup of solids? ❑ ❑ ❑ Are aerators/mixers acceptable? ❑ ❑ ❑ Page 4 of 5 Permit: WQ0001861 Owner - Facility: Gregory Poole Equipment Company Inspection Date: 10/22/2019 Inspection Type : Compliance Evaluation Reason for Visit: Routine Is effluent structure acceptable? ❑❑■❑ If present, is pond cover acceptable? ❑ ❑ 0 ❑ Comment: Top and outside berms maintained, inside berms have vegetation in need of removal. Pond is not in use. Page 5 of 5