Loading...
HomeMy WebLinkAboutNCG080964_Inspection Report_20191022IZOY COOPER 1IICHAEL, S. REt,As4 S, DANIEL SMITH October 22. 2019 Amazon.com Services, Inc. Attn: Eric Chapman 1805 TW Alexander Drive Durham, NC 27703 Subject: COMPLIANCE EVALUATION INSPECTION Amazon.com Services, Inc. Durham Facility, Certificate of Coverage-NCG080964 NPDES Stormwater General Perm it-NCG080000 Durham County Mr. Chapman: On October 3, 2019 a site inspection was conducted for the Amazon.com Services, Inc. facility located at the 1085 TW Alexander Drive Facility, Durham County, North Carolina. A copy of the Compliance Inspection Report is enclosed for your review. The site visit and file review revealed that the subject facility is covered by NPDES Stormwater General Permit-NCG080000, Certificate of Coverage- NCG080964. Permit coverage authorizes the discharge of stormwater from the facility to receiving waters designated as Stirrup Iron Creek, a Class C;NSW waterbody in the Neuse River Basin. As a result of the inspection, the facility was found to be in compliance with the conditions of the NCG080000 permit. Please refer to the enclosed Compliance Inspection Report for additional comments and observations made during the inspection. Please be advised that violations of the NPDES Stormwater General Permit are subject to a civil penalty assessment of up to $25,000 per day for each violation. If you or your staff has any questions, comments, or needs assistance with understanding any aspect of your permit, please contact me at (919) 791-4200 or by e-mail at Thad. valent neC(Dr,cclenr gov. Sincerely - Thad Valentine Environmental Senior Specialist Enclosure cc: RRO — Land Quality Section, Stormwater Files-NCG080964 far -+A. •1 � � Imo/%ti, Compliance Inspection Report Permit: NCG080964 Effective: 111OV18 Expiration: 05/31/21 Owner: Amazon Com Services Inc SOC: Effective: Expiration; Facility: Amazon. com Services Inc - RDU5 County: Durham 1805 Tw Alexander Or Region: Raleigh Durham NC 27703 Contact Person: Eric Chapman Title: Phone: 206-413-4526 Directions to Facility: intersection of presidential dr and tw aexander dr, go east .6 mile, facility on the left. System Classifications: Primary ORC: Certification: Phone: Secondary ORC(s): On -Site Representative(s): Related Permits: Inspection Date: 10/012019 Entry Time: 10 30AM Exit Time: 01 OOPM Primary Inspector: Thaddeus W Valentine Phone: Secondary Inspoctor(s): Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: Transportation w/VehFcle Maintenance; Petroleum Bulk/Oil Water Separator Stormwater Discharge COC Facility Status: Compliant Not Compl ant Question Areas: X Storm Water (See attachment summary) Page 1 of 3 Permit: NCG060964 owner - Facility: Amazon Corn Services Inc Inspection Date: 1010312019 Inspection Type : Compliance Evaluation Reason for Visit: Routine Inspection Summary: This facility is in the process of converting from an NCG08 general permit to an NCG06 permit. Once the NCG06 permit has been approved the rescission of the NCG08 will be finalized and the facility will need to follow the sample requirements for the NCG06 general permit. The (1)outfall was not located during the inspection and will need to be located and clearly shown on the map with a detailed route and directions to the outfall location. We recommend that the feasibility study includes any upgrades and improvements to the facility that benefit the stormwater. Outline the facility property line on the site map Add a list of significant spills in the SP3 even if there are none, for each year Implement the yearly illicit discharge evaluation Page 2 of 3 Permit: NCGO80964 Owner- Facility: Amazon Com Services Inc Inspection Date, 10/03/2019 Inspection Type : Compliance Evaluation Reason for Vis It. Routirc Stormwater Pollution Prevention Plan Yes No NA NE Does the site have a Stormwater Pollution Prevention Plan? 0 ❑ ❑ ❑ # Does the Plan include a General Location (USGS) map? E ❑ ❑ C1 # Does the Plan include a "Narrative Description of Practices"? E ❑ ❑ ❑ # Does the Plan include a detailed site map including outfall locations and drainage areas? ❑ ❑ ❑ # Does the Plan include a list of significant spills occurring during the past 3 years? ❑ 0 ❑ ❑ # Has the facility evaluated feasible alternatives to current practices? R ❑ ❑ ❑ # Does the facility. provide all necessary secondary containment? 0 ❑ ❑ ❑ # Does the Plan include a BMP summary? ❑ ❑ ❑ # Does the Plan include a Spill Prevention and Response Plan (SPRP)? ❑ ❑ ❑ # Does the Plan include a Preventative Maintenance and Good Housekeeping Plan? ❑ ❑ ❑ # Does the facility provide and document Employee Training? ❑ ❑ ❑ # Does the Plan include a list of Responsible Party(s)? ❑ ❑ ❑ # Is the Plan reviewed and updated annually? ❑ ❑ ❑ # Does the Plan include a Stormwater Facility Inspection Program? ❑ ❑ ❑ Has the Stormwater Pollution Prevention Plan been implemented? ® ❑ ❑ ❑ Comment: They need outline the property boundary on the topo map. Include a„yearly response for the „list of spills. Qualitatiye_Monitorin9 Yes No NA NE Has the facility conducted its Qualitative Monitoring semi-annually? ® ❑ ❑ ❑ Comment: Good Analytical Monitoring Yes No NA NE Has the facility conducted its Analytical monitoring? ❑ Z ❑ ❑ # Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas? ❑ 0 ❑ ❑ Comment: No analytical samples have been taken, Once the new permit is issued. begin sampling as required by the permit Permit and Outfalls Yes No NA NE # Is a copy of the Permit and the Certificate of Coverage available at the site? ! ❑ ❑ ❑ # Were all outfalls observed during the inspection? ❑ 0 ❑ ❑ # If the facility has representative outfall status. is it properly documented by the Division? 110 ❑ ❑ # Has the facility evaluated all illicit (non stormwater) discharges? ❑ E ❑ ❑ Comment: The facility has only one outfall and the outfall could not be located. Have your environmental consultant locate the outfall and provide details on the site map to help identify exactly where it is. How far from the curb inlet- in which direction. Please perform the annual illicit discharge inspection Page 3 of 3