Loading...
HomeMy WebLinkAboutNC0048305_Fact Sheet_20190822FACT SHEET FOR EXPEDITED PERMIT RENEWALS This form must be completed by Permit Writers for all expedited permits which do not require full Fact Sheets. Expedited permits are generally simple 100% domestics (e.g., schools, mobile home parks, etc) that can be administratively renewed with minor changes, but can include facilities with more complex issues (Special Conditions, 303(d) listed water, toxicity testing, instream monitoring, compliance concerns). Basic Information for Expedited Permit Renewals Permit Writer / Date Sydney Carpenter 8/22/2019 Permit Number NCO048305 Facility Name / Facility Class Carolina Yarn Processors / PC-1 Basin Name / Sub -basin number Broad River Basin / 03-08-06 Receiving Stream / HUC Little Creek / 030501051201 Stream Classification / Stream Segment C / Index: 9-55-1-11.5 Does permit need Daily Max NH3 limits? No Does permit need TRC limits/language? N/A Does permit have toxicity testing? No Does permit have Special Conditions? No Does permit have instream monitoring? Yes, for Turbidity. Is the stream impaired (on 303(d) list)? No Any obvious compliance concerns? Multiple problems with TSS since 2013 renewal. Enforcement case in 2015, NOVs in 2018, 2016, 2014, and NOD in 2014. Any permit mods since last permit? No New expiration date 7/31/2023 Facility Overview: Carolina Yarn Processors applies conventional water treatment technology to non -process contact wastewater. Facility discharges to surface waters for 6 hours max twice per year (Outfall 001), 4 hours once per year or as needed (Outfall 002), and on average 4 hours monthly or as needed (Outfall 003). Total discharge averages 3,528 gal/month (Combined Outfalls 001, 002, 003). Compliance History: • Enforcement case in 2015 regarding TSS limit violations • Multiple NOVs from 2013-2018, all for TSS limit violations. Reasonable Potential Analysis (RPA) — Renewal Summary: • Permit application does not state if Iron sulfate or ferrous sulfate has the potential to be discharged. An RPA for Outfall 003 was performed using the old freshwater standard of 1 mg/L for Iron. Per the 2007-2014 Triennial Review, Iron no longer has a WQS and as only four values exceeded 1 mg/L out of the past 4 '/2 years of Iron DMR data, the permit writer has removed monitoring for Iron from the effluent table. • Outfalls 001 & 002 discharged yearly. The Iron values for these two outfalls have not exceeded the old freshwater standard of 1 mg/L and Iron no longer has a recommended limit, therefore the permit writer has removed Iron from the effluent table, per 2007- 2014 Triennial Review. • Per "Assistance with BPJ on WTP renewals" 2012 Memo, Aluminum does not require an RPA. Renewal application states Aluminum chloride (polymer) is added in Primary Basin and has potential to be discharged from all three outfalls. Therefore, Aluminum monitoring will stay in renewal permit with the same monitoring frequency as the previous permit renewal. Changes from previous permit to draft: • Added regulatory citations • Added facility grade. • Updated receiving stream information. Previously known as UT to N Pacolet River, but has been updated to Little Creek and confirmed with ARO. • Updated eDMR language in Footnote 1 in Section A. (1). • Removed Iron parameter in A. (1) Effluent table for Outfalls 001 & 002 and in A. (2) Effluent table for Outfall 003. Iron does not have a recommended limit and was monitoring only in previous permit. All reported values in previous four and a half years are < 1 mg/L for Outfalls 001 & 002, and only four values exceeded 1 mg/L for Outfall 003. • Updated electronic reporting language in Section A. (3). Changes from draft to final: • No changes. Comments received on draft permit: • No comments received. Wafer Resources ENVIRONMENTAL QUALITY January 31, 2018 David Moore Fendrich Industries Inc PO Box 1579 Tryon, NC 28782-1579 Subject: Permit Renewal Application No. NCO048305 Carolina Yarn Processors Polk County Dear Applicant: ROY COOPER G"erraor NUCHAEL S- REGAN secrete. LLNDA CULPEPPER Ixterim Directa* The Water Quality Permitting Section acknowledges the January 30, 2018 receipt of your permit renewal application and supporting documentation. Your application will be assigned to a permit writer within the Section's NPDES WW permitting branch. Per G.S. 15OB-3 your current permit does not expire until permit decision on the application is made. Continuation of the current permit is contingent on timely and sufficient application for renewal of the current permit. The permit writer will contact you if additional information is required to complete your permit renewal. Please respond in a timely manner to requests for additional information necessary to allow a complete review of the application and renewal of the permit. Information regarding the status of your renewal application can be found online using the Department of Environmental Quality's Environmental Application Tracker at: https://deq.nc.ciov/permits-regulations/permit-guidance/environmental-application-tracker If you have any additional questions about the permit, please contact the primary reviewer of the application using the links available within the Application Tracker. Sincerely, Wren Thedford Administrative Assistant Water Quality Permitting Section cc: Central Files w/application(ARO) ec: WQPS Laserfiche File w/application State of North Carolina I Environmental Quality I Water Resources 1617 Mail Service Center I Raleigh, North Carolina 27699-1617 919-807-6300 Carolina Yarn Processors Division of Fendrich Industries, Inc. 250 Scriven Road P.O. Box 1579 Tryon, NC 28782 Phone: 828-859-5891 Mr. Wren Thedford NC DENR/DWR/NPDES Unit 1617 Mail Service Center Raleigh, NC 27699-1617 Dear Mr. Thedford: January 25, 2018 RECEIVE®!®ENR/DWR JAN 3 0 2018 Water Resources Permitting Section This letter is to request renewal of our NPDES Permit number NCO048305 which will expire on July 31, 2018. Enclosed is the completed application form. Sincerely, David M. Moore President Fendrich Industries, Inc. NPDES PERMIT APPLICATION — SHORT FORM C — Minor Industrial Minor industrial, manufacturing and commercial facilities. Mail the complete application to: N. C. Department of Environment and Natural Resources Division of Water Quality / NPDES Unit 1617 Mail Service Center, Raleigh, NC 27699-1617 NPDES Permit Number INCO048305 Please print or type. 1. Contact Information: RECE9VE[3tC)ENR1DW Owner Name Fendrich Industries, Inc. JAN 3 ® 2918 Facility Name CAROLINA YARN PROCESSORS Water Ftesaurces Mailing Address PO BOX 1579 PerMI UMY City TRYON State / Zip Code NORTH CAROLINA 28782 Telephone Number 828-859-5891 Fax Number 828-859-9024 e-mail Address dmoore@fendrichindustries.com 2. Location of facility producing discharge: Check here if same as above ❑ Street Address or State Road 250 SCRIVEN ROAD City TRYON State / Zip Code NORTH CAROLINA 28782 County POLK L 3. Operator Information: Name of the firm, consultant or other entity that operates the facility. (Note that this is not refemng to the Operator in Responsible Charge or ORC) Name CAROLINA YARN PROCESSORS Mailing Address PO BOX 1579 City TRYON State / Zip Code NORTH CAROLINA 28782 Telephone Number 828-859-5891 Fax Number 828-859-9024 4. Ownership Status: Federal ❑ State ❑ Private XX Public ❑ Page 1 of 5 C-MI 10/08 NPDES PERMIT APPLICATION - SHORT FORM C - Minor Industrial Minor industrial, manufacturing and commercial facilities. 5. Standard Industrial Classification (SIC) code(s): 2284 6. Number of employees: 50 7. Describe the treatment system List all installed waste treatment components with capacities, describe the processes that generate wastewaters. If the space provided is not sufficient attach a separate sheet of paper with the system description. PLEASE SEE ATTACHED PAGE 8. Is facility covered under federal effluent limitation guidelines? No X® Yes ❑ If yes, specify the category? 9. Principal product(s) produced: Bleached & dyed yarn and cloth, print cloth Principal raw material(s) consumed: Process natural & synthetic yarn and cloth Briefly describe the manufacturing process(es): Wet processing of cotton and synthetic yarns: Bleach and dye for companies who weave fabric. Wind yarn onto dye tubes, dye, dry dyed yarn, wind onto cones, pack and ship. Bleach and dye or print cloth, both 100% cotton and 50/50 poly/cotton blend; put on rolls and ship. Page 2 of 5 C-MI 10/08 Carolina Yarn Processors Division of Fendrich Industries, Inc. January 22, 2018 250 Scriven Road P.O. Box 1579 Tryon, NC 28782 Phone: 828-859-5891 WATER TREATMENT SYSTEM Primary and Secondary Sedimentation Basins Polymer Feed System Flow Equalization Sand Filter Beds Filtration System Primary Sedimentation Basin Water from our pond is channeled to the Primary Basin (145,000-gallon capacity) where polymer and caustic are added to clear turbidity and control PH. Sand Filter Beds Sediment and solids build up in the Primary Basin which requires emptying and cleaning basin no more than twice annually. Contents are washed to a flow equalization chamber and then piped to the Sand Beds. Sediment is filtered as water passes through the sand and then the water is discharged to the stream. Outfall #001 Secondary Sedimentation Basin Water from the Primary Basin is piped to the Secondary Basin (92,000-gallon capacity) where remaining turbidity settles. As sediment builds up, the basin is cleaned and discharged to the stream annually. Outfall #002 Filtration System Water from the Secondary Basin is piped to Filter Tanks (8,000-gallon capacity) and then piped into the plant for use in yarn and fabric dyeing equipment. The filters are backwashed and discharged to the stream as needed. Outfall #003 NPDES PERMIT APPLICATION - SHORT FORM C - Minor Industrial Minor industrial, manufacturing and commercial facilities. 10. Amount of principal product produced or raw material consumed List spectlic amounts consumed and/or units of roduction over the last three ears Product Produced or Raw Material Consumed AVERAGE Product Produced or Raw Material Consumed PEAK per Day 3,950 lbs (250 days/yr) 4,540 lbs per Month 82,284 lbs 94,600 lbs per Year 987,415 lbs 1,135,200 lbs 11. Frequency of discharge: Continuous ❑ Intermittent X® If intermittent: Days per week discharge occurs: 1 Duration: #001: 6 hours max twice per year #002: 4 hours once per year #003: 4 hours average monthly 12. Types of wastewater discharged to surface waters only Discharge Flow (GALLONS PER DAY) Sanitary - monthly average N/A Utility water, etc. - monthly average N/A Process water - monthly average N/A Stormwater - monthly average 37,000 gallons average Other - monthly average Explain: Water from outfalls #001, #002, #003 3,528 gallons average Monthly Average total discharge (all types) 40,528 gallons average 13. Number of separate discharge points: 3 Outfall Identification number(s) 001, 002, 003 14. Name of receiving stream(s) (Provide a map showing the exact location of each outfall, including latitude and longitude): Unnamed tributary to the North Pacolet River in the Broad River Basin: MAP ATTACHED Page 3 of 5 C-MI 10/08 FCI�OIi�r'#�1f' Ch W � a „^� ,r� "• "•� •"r - 4 �'" ,fit ..a _ NC Hwy 108 '1 y • •• v� 5 ;1 �/��►.yjy{(/���� ij �''� :". '�1 * ice-- �� . _'"�}' '" -, • V�/ R • lid • a.� /.- �� 15115. '� `, b`� �. • v`d . r iti� �� , ��' �4 ;,,�=° ,' •� • r UT to North `Pacolet ♦t ? ' �. 4s, " "`�• a `its ,r'�` Rivet • �� f ;-�, .r,' ♦ (flows east) 00 fi^. � r"1 ��. • s�w, �f t' +r '�a — , s • . 1, �t'c ` 9 " `s • � a C ScilvenRoad.a •���t r ``�, ` Itf"_ �;:,�.,;�',,`�..,,..• Outfalls 002 and 003 (flow-E) __� �— w • �., e Lat 35, 13 'a 05" Approximate Facility • �i '' •��` }� Long $2; 14' 09" Boundary • "--.. �,.� � l �-�'r1 -�.. �• ti 01 • � i r,----...._ ��, '-� •�`1t yam..✓ ; ��,,�� 1� s �`-r � • �'t� . `,�� ..--�. �° + :'��" • Outfall 001 C� •F Iw �_. . . • ,� j : . :!� �;'!� . ►f (flows I , + i ;�i ; ��.V ,� f"� = `��,,,_,,._.�.�.� .�'"_,�" � {� � `r �- "�r 1��� -�''; —= � ,,,tip • ram`=--"• « - 'fir •-�. i ♦ *' � ! • _/`" � s • + •i s �NC Hwy 176 i ■�.� • •f" 11 Sao♦{ems. l 'tf�`—..._51` �j��`: �� ♦ 4 1 ��`�r✓` 41 •\ • t t r l � • •� i f r � �Ile ,•i a • f ► / A M1 t i [� % -fir r `Y. � * • �v, `• ' ,�.�.���'• €1. • :�.-, r__�';,z;,�la ic_ .t � ;t3:1�.•.l t�C �, � 5 Fendrich Inds -tries, Inc. Carolina Yarn 'Processors, Trion State Grid/Quad (il ONW / Landrum, SG Sub-13as111 03-08-06 Pet mrtted Flow not limited Stream Class C RccervmQ Stream. UI to North Pacolet Rner Stt cam Sef ment 9-5'5-1-(10) UtamacceMigui BtoadRivci,Bat tm IIUC 03050105 Facility Location not to scale North NPDES Peimrt NC0048305 � Polk County NPDES PERMIT APPLICATION - SHORT FORM C - Minor Industrial Minor industrial, manufacturing and commercial facilities. 15. Effluent Data [for new or proposed discharges] Provide data for the parameters listed. Temperature and pH shall be grab samples, for all other parameters 24-hour composite sampling shall be used If more than one analysts is reported, report daily maximum and monthly average. If only one analysts is reported, report as daily maximum. NOTE: Permittees requesting renewal should complete the table ONLY for the parameters currently monitored. Summarize the past 3 years of effluent data. Parameter Daily Maximum Monthly Average Units of Measurement Biochemical Oxygen Demand (BOD5) Chemical Oxygen Demand (COD) Total Organic Carbon Total Suspended Solids 9.6 6.4 Mg/L Ammonia as N Temperature (Summer) Temperature (Winter) pH 7.5 7.0 Fecal Coliform (If sanitary waste is present) Total Residual Chlorine (if chlorme is used) 16. List all permits, construction approvals and/or applications (check all that apply and provide permit numbers or check none tf not applicable): Type Permit Number Type Permit Number Hazardous Waste (RCRA) NESHAPS (CAA) UIC (SDWA) Ocean Dumping (MPRSA) NPDES NCO048305 Dredge or fill (Section 404 or CWA) PSD (CAA) Other Non -attainment program (CAA) 17. List any chemicals that may be discharged (Please list and explain source and potential amounts.) Polymer (CAS#7446-70-0) and Caustic (CAS# 1310-73-2) are added to water in the Primary Basin. By the time the diluted solution goes through the system and the sand beds, the amount that could make it to the stream would only be a trace if any. Page 4 of 5 C-MI 10108 NPDES PERMIT APPLICATION - SHORT FORM C - Minor Industrial Minor industrial, manufacturing and commercial facilities. 18. Is this facility located on Indian country? (check one) Yes ❑ No XX 19. Applicant Certification I certify that I am familiar with the information contained in the application and that to the best of my knowledge and belief such information is true, complete, and accurate. David M. Moore President Printed name of Person Signing Title /M , 1/2,C/2 b IS Signature of Applicant Date North Carolina General Statute 143-215.6 (b)(2) provides that Any person who knowingly makes any false statement representation, or certification in any application, record, report, plan, or other document files or required to be maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article, or who falsifies, tampers with, or knowingly renders inaccurate any recording or monitoring device or method required to be operated or maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article, shall be guilty of a misdemeanor punishable by a fine not to exceed $25,000, or by imprisonment not to exceed six months, or by both. (18 U.S.C. Section 1001 provides a punishment by a fine of not more than $25,000 or imprisonment not more than 5 years, or both, for a similar offense.) Page 5 of 5 C-MI 10/08 Carolina Yarn Processors Division of Fendrich Industries, Inc. January 25, 2018 250 Scriven Road P.O. Box 1579 Tryon, NC 28782 Phone: 828-859-5891 Mr. Wren Thedford NC DENR/DWR/NPDES Unit 1617 Mail Service Center Raleigh, NC 27699-1617 Dear Mr. Thedford: Regarding management of our sludge or solids, sedimentation from the primary sedimentation basin is discharged to the sand beds. Solids are separated as the water passes through the sand beds before being discharged to the stream. On -site storage occurs before the solids are loaded and disposed of at the county landfill. The primary basin requires being emptied and cleaned a maximum of twice per year. Sedimentation may be discharged many times to the sand beds before disposal is required. Sincerely, David M. Moore President Fendrich Industries, Inc. Freshwater RPA - 95% Probability/95% Confidence Using Metal Translators MAXIMUM DATA POINTS = 58 REQUIRED DATA ENTRY Table 1. Project Information ]CHECK IF HQW OR ORW WQS Facility Name Par01 Carolina Yarn Processors WWTP/WTP Class PC-1 Par02 NPDES Permit NCO048305 Par03 Outfall 001 Par04 Flow, Qw (1 0.050 Par05 Receiving Stream Little Creek Par06■ HUC Number 03050105 Par07 Stream Class C 0.00 Paro8 Par09 Par10 ]Apply WS Hardness WQC 7Q10s (cfs) 7Q10w (cfs) 0.00 Par11 311 (cfs) 0.00 Par12 QA (cfs) 0.00 Par13 1Q10s (cfs) Par14 Par15 0.00 Effluent Hardness NO EFFLUENT HARDNESS DATA ----------------------------------- Upstream Hardness NO UPSTREAM HARDNESS DATA I Par16 - _ Combined Hardness Chronic - - -- - DATA INCOMPLETE I Par17 -- — Combined Hardness Acute ----- ---------- ---- -- DATA INCOMPLETE ------I I Par18 I Par19 Par20 Data Source(s) ❑CHECK TO APPLY MODEL Par21 Par22 Par23 Par24 Table 2. Parameters of Concern Name WQS Type Chronic Modifier Acute i Units Arsenic Aquactic Life C 150 FW 340 ug/L Arsenic Human Health Water Supply C 10 Hi N/A ug/L Beryllium Aquatic Life NC 6.5 FW 65 ug/L Cadmium Aquatic Life NC NO DATA FW NO DATA ug/L Chlorides Aquatic Life NC 230 FW Chlorinated Phenolic Compounds Water supply NC 1 A ug/L Total Phenolic Compounds Aquatic Life NC 300 A ug/L Chromium III Aquatic Life NC NO DATA FW NO DATA ug/L Chromium VI Aquatic Life NC 11 FW 16 pg/L Chromium, Total Aquatic Life NC N/A FW N/A pg/L Copper Aquatic Life NC NO DATA FW NO DATA ug/L Cyanide Aquatic Life NC 5 FW 22 10 ug/L Fluoride Aquatic Life NC 1,800 FW ug/L Lead Aquatic Life NC NO DATA FW NO DATA ug/L Mercury Aquatic Life NC 12 FW 0.5 ng/L Molybdenum Human Health NC 2000 HH ug/L Nickel Aquatic Life NC NO DATA FW NO DATA pg/L Nickel Water Supply INC 25.0000 WS N/A pg/L Selenium Aquatic Life INC 5 FW 56 ug/L Silver Aquatic Life NC 0.06 FW NO DATA ug/L Zinc Aquatic Life NC NO DATA FW NO DATA ug/L Iron Aquatic Life NC 1 FW mg/L NCO048305 RPA 2019 001, input 3/27/2019 Carolina Yarn Processors - NC0048305 Freshwater RPA - 95% Probability/95% Confidence Using Metal Translators MAXIMUM Qw (MGD) = 0.0500 1Q10S (cfs) = 0.00 7Q10S (cfs) = 0.00 7Q10W (cfs) = 0.00 30Q2 (cfs) = 0.00 Avg. Stream Flow, QA (cfs) = 0.00 Receiving Stream: Little Creek HUC 03050105 DATA POINTS = 58 WWTP/WTP Class: PC-1 IWC% @ 1Q10S = 100 IWC% @ 7Q10S = 100 IWC% @ 7Q10W = 100 1WC% @ 30Q2 = 100 IW%C @ QA = 100 Stream Class: C Outfall 001 Qw = 0.05 MGD COMBINED HARDNESS (me/L) NO DATA NO DATA PARAMETER NC STANDARDS OR EPA CRITERIA REASONABLE POTENTIAL RESULTS RECOMMENDED ACTION TYPE a Applied Chronic Acute n # Det. Max Pred Cw Allowable Cw Standard Acute: NO WQS Iron NC 1 FW mg ; L 2 2 3.79000 Note: n <_ 9 C.V. (default) Chronic: 1.00000 RP for Limited Dataset (n<8 samples) - no WQS, so Limited data set No value > Allowable Cw no monitoring required. Acute: 0 0 N/A — -Chronic: ---------- -------------------------- Acute: 0 0 N/A _ __________ Chronic: Acute: 0 0 N/A _ __________ Chronic: _ NCO048305 RPA 2019 001, rpa Page 1 of 1 3/27/2019 REASONABLE POTENTIAL ANALYSIS Par22 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 Iron Date Data BDL=1/2DL 5/21/2015 1 1 7/5/2016 0.5 0.5 Use"PASTE SPECIAL Values" then "COPY" . Maximum data points = 58 Results Std Dev. 0.3536 Mean 0.7500 C.V. (default) 0.6000 n 2 Mult Factor = 3.79 Max. Value 1.000000 mg/L Max. Fred Cw 3.790000 mg/L -1- NCO048305 RPA 2019 001, data 3/27/2019 Freshwater RPA - 95% Probability/95% Confidence Using Metal Translators MAXIMUM DATA POINTS = 58 REQUIRED DATA ENTRY Table 1. Project Information ]CHECK IF HQW OR ORW WQS Facility Name Par01 Carolina Yarn Processors WWTP/WTP Class PC-1 Par02 NPDES Permit NCO048305 Par03 Outfall 002 Par04 Flow, Qw (1 0.050 Par05 Receiving Stream Little Creek Par06■ HUC Number 03050105 Par07 Stream Class C 0.00 Paro8 Par09 Par10 ]Apply WS Hardness WQC 7Q10s (cfs) 7Q10w (cfs) 0.00 Par11 311 (cfs) 0.00 Par12 QA (cfs) 0.00 Par13 1Q10s (cfs) Par14 Par15 0.00 Effluent Hardness NO EFFLUENT HARDNESS DATA ----------------------------------- Upstream Hardness NO UPSTREAM HARDNESS DATA I Par16 - _ Combined Hardness Chronic - - -- - DATA INCOMPLETE I Par17 -- — Combined Hardness Acute ----- ---------- ---- -- DATA INCOMPLETE ------I I Par18 I Par19 Par20 Data Source(s) ❑CHECK TO APPLY MODEL Par21 Par22 Par23 Par24 Table 2. Parameters of Concern Name WQS Type Chronic Modifier Acute i Units Arsenic Aquactic Life C 150 FW 340 ug/L Arsenic Human Health Water Supply C 10 Hi N/A ug/L Beryllium Aquatic Life NC 6.5 FW 65 ug/L Cadmium Aquatic Life NC NO DATA FW NO DATA ug/L Chlorides Aquatic Life NC 230 FW Chlorinated Phenolic Compounds Water supply NC 1 A ug/L Total Phenolic Compounds Aquatic Life NC 300 A ug/L Chromium III Aquatic Life NC NO DATA FW NO DATA ug/L Chromium VI Aquatic Life NC 11 FW 16 pg/L Chromium, Total Aquatic Life NC N/A FW N/A pg/L Copper Aquatic Life NC NO DATA FW NO DATA ug/L Cyanide Aquatic Life NC 5 FW 22 10 ug/L Fluoride Aquatic Life NC 1,800 FW ug/L Lead Aquatic Life NC NO DATA FW NO DATA ug/L Mercury Aquatic Life NC 12 FW 0.5 ng/L Molybdenum Human Health NC 2000 HH ug/L Nickel Aquatic Life NC NO DATA FW NO DATA pg/L Nickel Water Supply INC 25.0000 WS N/A pg/L Selenium Aquatic Life INC 5 FW 56 ug/L Silver Aquatic Life NC 0.06 FW NO DATA ug/L Zinc Aquatic Life NC NO DATA FW NO DATA ug/L Iron Aquatic Life NC 1 FW mg/L NCO048305 RPA 2019 002, input 3/27/2019 Carolina Yarn Processors - NC0048305 Freshwater RPA - 95% Probability/95% Confidence Using Metal Translators MAXIMUM Qw (MGD) = 0.0500 1Q10S (cfs) = 0.00 7Q10S (cfs) = 0.00 7Q10W (cfs) = 0.00 30Q2 (cfs) = 0.00 Avg. Stream Flow, QA (cfs) = 0.00 Receiving Stream: Little Creek HUC 03050105 DATA POINTS = 58 WWTP/WTP Class: PC-1 IWC% @ 1Q10S = 100 IWC% @ 7Q10S = 100 IWC% @ 7Q10W = 100 1WC% @ 30Q2 = 100 IW%C @ QA = 100 Stream Class: C Outfall 002 Qw = 0.05 MGD COMBINED HARDNESS (me/L) NO DATA NO DATA PARAMETER NC STANDARDS OR EPA CRITERIA REASONABLE POTENTIAL RESULTS RECOMMENDED ACTION TYPE a Applied Chronic Acute n # Det. Max Pred Cw Allowable Cw Standard Acute: NO WQS Iron NC 1 FW mg 2 2 1.97080 Note: n <_ 9 C.V. (default) Chronic: 1.00000 RP for Limited Dataset (n<8 samples) - no WQS, so Limited data set No value > Allowable Cw no monitoring required. Acute: 0 0 N/A — -Chronic: ---------- -------------------------- Acute: 0 0 N/A _ __________ Chronic: Acute: 0 0 N/A _ __________ Chronic: _ NCO048305 RPA 2019 002, rpa Page 3 of 3 3/27/2019 REASONABLE POTENTIAL ANALYSIS Par22 Use"PASTE SPECIAL Iron Values" then "COPY" . Maximum data points = 58 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 Date Data BDL=1/2DL 5/21 /2015 0.52 0.52 7/5/2016 0.05 0.05 Results Std Dev. 0.3323 Mean 0.2850 C.V. (default) 0.6000 n 2 Mult Factor = 3.79 Max. Value 0.520000 mg/L Max. Fred Cw 1.970800 mg/L -1- NCO048305 RPA 2019 002, data 3/27/2019 Freshwater RPA - 95% Probability/95% Confidence Using Metal Translators MAXIMUM DATA POINTS = 58 REQUIRED DATA ENTRY Table 1. Project Information ]CHECK IF HQW OR ORW WQS Facility Name Par01 Carolina Yarn Processors WWTP/WTP Class PC-1 Par02 NPDES Permit NCO048305 Par03 Outfall 003 Par04 Flow, Qw (1 0.171 Par05 Receiving Stream Little Creek Par06■ HUC Number 03050105 Par07 Stream Class C 0.00 Paro8 Par09 Par10 ]Apply WS Hardness WQC 7Q10s (cfs) 7Q10w (cfs) 0.00 Par11 311 (cfs) 0.00 Par12 QA (cfs) 0.00 Par13 1Q10s (cfs) Par14 Par15 0.00 Effluent Hardness NO EFFLUENT HARDNESS DATA ----------------------------------- Upstream Hardness NO UPSTREAM HARDNESS DATA I Par16 - _ Combined Hardness Chronic - - -- - DATA INCOMPLETE I Par17 -- — Combined Hardness Acute ----- ---------- ---- -- DATA INCOMPLETE ------I I Par18 I Par19 Par20 Data Source(s) ❑CHECK TO APPLY MODEL Par21 Par22 Par23 Par24 Table 2. Parameters of Concern Name WQS Type Chronic Modifier Acute i Units Arsenic Aquactic Life C 150 FW 340 ug/L Arsenic Human Health Water Supply C 10 Hi N/A ug/L Beryllium Aquatic Life NC 6.5 FW 65 ug/L Cadmium Aquatic Life NC NO DATA FW NO DATA ug/L Chlorides Aquatic Life NC 230 FW Chlorinated Phenolic Compounds Water supply NC 1 A ug/L Total Phenolic Compounds Aquatic Life NC 300 A ug/L Chromium III Aquatic Life NC NO DATA FW NO DATA ug/L Chromium VI Aquatic Life NC 11 FW 16 pg/L Chromium, Total Aquatic Life NC N/A FW N/A pg/L Copper Aquatic Life NC NO DATA FW NO DATA ug/L Cyanide Aquatic Life NC 5 FW 22 10 ug/L Fluoride Aquatic Life NC 1,800 FW ug/L Lead Aquatic Life NC NO DATA FW NO DATA ug/L Mercury Aquatic Life NC 12 FW 0.5 ng/L Molybdenum Human Health NC 2000 HH ug/L Nickel Aquatic Life NC NO DATA FW NO DATA pg/L Nickel Water Supply INC 25.0000 WS N/A pg/L Selenium Aquatic Life INC 5 FW 56 ug/L Silver Aquatic Life NC 0.06 FW NO DATA ug/L Zinc Aquatic Life NC NO DATA FW NO DATA ug/L Iron Aquatic Life NC 1 FW mg/L NCO048305 RPA 2019 003, input 3/27/2019 Carolina Yarn Processors - NC0048305 Freshwater RPA - 95% Probability/95% Confidence Using Metal Translators MAXIMUM Qw (MGD) = 0.1710 1Q10S (cfs) = 0.00 7Q10S (cfs) = 0.00 7Q10W (cfs) = 0.00 30Q2 (cfs) = 0.00 Avg. Stream Flow, QA (cfs) = 0.00 Receiving Stream: Little Creek HUC 03050105 DATA POINTS = 58 WWTP/WTP Class: PC-1 IWC% @ 1Q10S = 100 IWC% @ 7Q10S = 100 IWC% @ 7Q10W = 100 1WC% @ 30Q2 = 100 IW%C @ QA = 100 Stream Class: C Outfall 003 Qw = 0.171 MGD COMBINED HARDNESS (me/L) NO DATA NO DATA PARAMETER NC STANDARDS OR EPA CRITERIA REASONABLE POTENTIAL RESULTS RECOMMENDED ACTION TYPE a Applied Chronic Acute n # Det. Max Pred Cw Allowable Cw Standard Acute: NO WQS Iron NC 1 FW mg/L 38 32 6.51700 _ _ _ _ _ _ Chronic: 1.00000 _ _ _ _ _ _ _ _ _ _ _ _ _ _ RP shown - However, Iron no longer has a WQS 4 values > Allowable Cw Removing monitoring from permit. Acute: 0 0 N/A — -Chronic: ---------- -------------------------- Acute: 0 0 N/A _ __________ Chronic: Acute: 0 0 N/A _ __________ Chronic: _ NCO048305 RPA 2019 003, rpa Page 1 of 1 3/27/2019 REASONABLE POTENTIAL ANALYSIS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 Use "PASTE SPECIAL Iron Values" then "COPY" . Maximum data points = 58 Date Data BDL=1/2DL Results 9/2/2014 0.066 0.066 Std Dev. 0.9968 9/9/2014 0.2 0.2 Mean 0.4401 9/16/2014 0.088 0.088 C.V. 2.2650 9/23/2014 < 0.05 0.025 n 38 9/30/2014 0.41 0.41 10/7/2014 < 0.05 0.025 Mult Factor = 1.33 10/14/2014 < 0.05 0.025 Max. Value 4.900000 mg/L 10/21/2014 0.1 0.1 Max. Pred Cw 6.517000 mg/L 10/28/2014 0.12 0.12 11/4/2014 0.68 0.68 11/11/2014 0.13 0.13 11/18/2014 < 0.05 0.025 11/25/2014 0.27 0.27 12/2/2014 3.8 3.8 12/9/2014 0.053 0.053 12/16/2014 1.4 1.4 12/30/2014 0.057 0.057 1/6/2015 0.17 0.17 1/13/2015 1.2 1.2 1/20/2015 0.052 0.052 1/27/2015 < 0.05 0.025 2/3/2015 0.054 0.054 4/14/2015 0.1 0.1 7/14/2015 < 0.005 0.0025 10/6/2015 4.9 4.9 1/5/2016 0.37 0.37 4/5/2016 0.054 0.054 7/12/2016 0.67 0.67 10/4/2016 0.063 0.063 1/10/2017 0.073 0.073 4/4/2017 0.15 0.15 7/11/2017 0.05 0.05 10/3/2017 0.062 0.062 1/9/2018 0.85 0.85 4/3/2018 0.24 0.24 7/12/2018 0.05 0.05 10/9/2018 0.013 0.013 1/8/2019 0.1 0.1 -1- NCO048305 RPA 2019 003, data 3/27/2019 Publisher's Certificate of Publication STATE OF NORTH CAROLINA PUBLIC NOTICE COUNTY OF POLK North Carolina Environmental Management Commission/ Kevin Powell, being duly sworn, says: NPDES Unit That he is General Manager of theTryon Daily Bulle- 1617 Mail Service Center tin, a daily newspaper of general circulation, printed Raleigh, NC 27699-1617 and published in Tryon, Polk County, North Carolina- Notice of Intent to Issue a NP- that the publication, a copy of which is attached The Northwater Carolina PermitEnvi- hereto, was published in the said newspaper on the ronmental Management following dates: Commissionpropastewateoses s issue tewater ` discharge permit to the per- 06/25/19 sons) listed below. Written comments regarding the pro- posed permit will be accepted until 30 days after the pub - That said newspaper was regularly issued and 9 Y date of this notice. The Director of the NC Division circulated on those dates. of Water of water Resources (DWR) may hold a public hearing The sum charged by the Newspaper for said publi- should there be a significant cation does not exceed the lowest rate aid b P Y com- degree of public interest. Please mail comments and/ mercial customers for an advertisement of similar or information requests to size and frequency in the same newspaper in which DWR at the above address. the public notice appeared. Interested persons may visit the DWR at 512 N. Salisbury There are no agreements between the Tryon Daily Street, Raleigh, NC to review information on file. Additional Bulletin and the officer or attorney charged with the information on NPDES per - duty of placing the attached legal advertising no- mits and this notice may be tices wherebyan advantage, gain or profit accrued Y 9 9 P found .g our out/diiwebsitv hens/ deq.nc.gov/sbout/divisions/ to said officer or attorney. water-resources/water-re- so urces-permits/wastewa- SIGNED: ter-branch/npdes-wastewa- ter/public-notices,or byy callingg (919) 707-3601. Fendrich Industries, Inc., Polk Coun- ty, applied to renew NPDES Permit NC0048305/Carolina Yam Processors WTP. Facil- ity discharges to Little Creek/ Broad River Basin. Daily Bulletin: Kevin Powell, General Manager June FENDRICH INDUSTRIES Subscribed and sworn to before me this 25th Day of June, 2019 i Mary Jo Eskridge, Notary Public State of Alabama at Large My commission expires 03-05-2022 Account # 144932 Ad # 834689 NCDENR&DWQ&POINT SEARCH BRANCH 1617 MAIL SERVICE CENTER RALEIGH NC 27699