Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0040799_Site Plans/Maps_20191021
E Q 00 r 0 N N U 0 iT 3 0 0 0 0 3 0 Q 0 0 Z .E >5 (2 N Cz 0 0 0 0 7 O 0 0 m 0 0 N J i 14 C ROIN G ACE DRIP IRRIGATION IF=M;z TREAT SYSTEM WAKE COUNTY, NC - PROJECT No. A69601000 Apex V1111 ev;e -Rd 1147 CROCKETT R 1 D G E Apex Mature Park q? PaaKsroE are THE CREEK SITE 7� WHISTLING QUAIL FAIRFIELD PARK AT OOTTS MILLS SALE HOLLAND FARMS 1147 CREEKS BEND FARMS WOOOGATE FARMS Friendship WE TWI14D 2613 WHISTLING QUAIL RUN APEX, NC SCHEDULE OF DRAWINGS: COVER SHEET C-101 OVERALL SITE PLAN C-102 SYSTEM LAYOUT WINDING G R E E D-101 DETAILS - 1 D-102 DETAILS - 2 D-103 DETAILS - 3 117C E-101 ELECTRICAL DETAILS - 1 WINDING WAY ESTATES 1 PLEASANT PLAINS oil VICINITY MAP 11,��1111If1 �', OL I i CO) SEW- - 17069 � _f °d, s m AG. PROJECT MANAGEMENT COPYRIGHT © 2019 LICENSE No. C-1039 MacCONNELL & Associates, P. C. 1101 NOWELL RD., SUITE 118 RALEIGH, NORTH CAROLINA 27607 P. O. BOX 129 MORRISVILLE, NORTH CAROLINA 27560 TEL: (919) 467-1239 FAX: (919) 319-6510 J 1147 SITE Bella Casa 9 ,�{� Snipe �'t Sol La Mary I . O'donnell, RPH � hurch �rous� �r21t ���u fly fu 11i 47 a e ra 4L191 1i4 9 Greater Christian 2 Gha pel Church w Z lkq Ftoraor Apex Friendship High School 1'147 LOCATIO N M A P THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED UPON INFORMATION FURNISHED BY OTHERS. WHILE THIS INFORMATION IS BELIEVED TO BE RELIABLE, THE DESIGN PROFESSIONAL CANNOT ASSURE ITS ACCURACY, AND THUS IS NOT RESPONSIBLE FOR THE ACCURACY OF THIS RECORD DRAWING OR FOR ANY ERRORS OR OMMISSIONS WHICH MAY HAVE BEEN INCORPORATED INTO IT AS A RESULT. THOSE RELYING ON THIS RECORD DOCUMENT ARE ADVISED TO OBTAIN INDEPENDENT VERIFICATION OF ITS ACCURACY BEFORE APPLYING IT FOR ANY PURPOSE. RECORD DRAWING OCTOBER 21 2019 APRIL 12, 2019 w U) r 0 N W W Q ry (n I z ry z x O a U U w m w J Q Z 0 0 I O O 0 cn rn cn a SIJRFACF F- Q 00 �n N N N U 0 a) m m 0 O 0 a 3 0 E fl- 0 0 M N a 0 0 0 L 0 7 O co CD o Q N 4 J N 1 1. NOTES 1. CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF ALL TRADES AND SUBCONTRACTORS. CONTRACTOR IS ALSO RESPONSIBLE FOR FIELD VERIFYING DIMENSIONS, ELEVATIONS, AND LOCATIONS OF ALL EXISTING CONDITIONS AND UTILITIES. 2. CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE SOIL EROSION AND SEDIMENTATION CONTROL REQUIREMENTS. 3. CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE OSHA, NCDOT AND SAFETY REQUIREMENTS. 4. CONTRACTOR IS RESPONSIBLE FOR REPAIRING ALL CONSTRUCTION DAMAGE EXPEDITIOUSLY AND AT NO ADDITIONAL COST TO THE OWNER. 5. LOCATION OF DRIPPER LINES AS SHOWN ARE APPROXIMATE. LINES SHALL LAY PARALLEL TO CONTOURS @ 3FT. MIN. t 61N. SPACING AS SITE CONDITIONS ALLOW. 6. SUPPLY AND RETURN LINES MAY BE LAID IN SAME TRENCH. SEPARATION IS FOR ILLUSTRATION PURPOSES ONLY. 7. LAYOUT OF THE APPLICATION AREA IS BASED ON FIELD DELINEATION OF SOILS AREA BY A LICENSED SOILS CONSULTANT. ANY CHANGE IN LAYOUT BY THE CONTRACTOR OUTSIDE THE DELINEATED AREA SHALL BE APPROVED BY THE SOILS CONSULTANT AND THE ENGINEER. 8. DRAIN ALL ROOF AND TOE DRAINS AWAY FROM DRIP FIELD AND TREATMENT UNITS. 9. PROVIDE MINIMUM 100 FEET OF SEPARATION FROM ANY WELL AND TREATMENT AND DISPOSAL SYSTEMS. 10. NO SWIMMING POOL SHALL BE INSTALLED WITHIN 15 FEET OF IRRIGATION SITE. 11. PROPOSED DWELLING AND DRIVEWAY LOCATIONS ARE APPROXIMATE. ACTUAL LOCATIONS SHALL BE DETERMINED BY ARCHITECT. DO NOT DISTURB SOIL OR STORE BUILDING MATERIALS ON PROPOSED SEPTIC FIELD. 12. MANIFOLDS AND VALVES HAVE BEEN INCREASED IN SIZE FOR CLARITY. CONTRACTOR SHALL NOT INSTALL ANY PIPING OR VALVES WITHIN THE 50' PROPERTY LINE SETBACK OR 25' PROPERTY LINE SETBACK WITH WAIVER. OPERATING REGIME FOR DRIP IRRIGATION SYSTEM SYSTEM IS DESIGNED AND CONTROLS (MICROPROCESSORS) ARE PROVIDED TO DOSE THE E—Z TREAT FILTER WITH 34 GALLONS OF SEPTIC TANK EFFLUENT EVERY 14-20 MINUTES. THE MICROPROCESSOR WILL ALSO ACTIVATE THE DRIP IRRIGATION PUMP AND ASSOCIATED CONTROL VALVE TO DOSE THE DRIP IRRIGATION ZONES AT A PRE—SET TIME. FLOW TO THE DRIP IRRIGATION FIELD IS SET AS SHOWN ON THE GEOFLOW FIELD DOSING TABLE. PUMPED DRIP IRRIGATION FLOW SHALL PASS THROUGH A FLOW METER. WHEN THE PREPROGRAMMED VOLUME IS REACHED THE ACTIVE PUMP WILL BE DE —ENERGIZED. THE PUMP WILL ALSO DE —ENERGIZE IF THE LOW WATER LEVEL "PUMP OFF" SWITCH IS ACTIVATED. IF THE HIGH WATER LEVEL "ALARM" FLOAT SWITCH IS ACTIVATED, THE SYSTEM WILL BEGIN ITS OPERATION OF DELIVERING THE PREDETERMINED DOSE VOLUME, AND SHALL ALSO ENERGIZE THE AUDIBLE AND FLASHING ALARM FIXTURES. (ONCE ENERGIZED, THE FLASHING AND AUDIBLE ALARM UNITS WILL ONLY BE RESET MANUALLY OR BY REACHING LOW LEVEL CONDITIONS.) THE MICROPROCESSOR WILL ALSO CONTROL THE PERIODIC BACK WASHING OF THE VORTEX FILTER AND THE FLUSHING OPERATION OF THE SUB —FIELD LATERAL NETWORK. FILTER BACK WASHING SHALL OCCUR AT THE END OF EACH DOSE CYCLE. SYSTEM LATERAL FLUSHING SHALL OCCUR WHEN THE MICROPROCESSOR SENSES RECOGNITION OF A PRESET ELAPSED TIME SINCE LAST SYSTEM FLUSH (USUALLY 28 DAYS). THE SYSTEM SHALL BE CONFIGURED TO ALLOW FOR MANUAL INITIATION OF BACK WASHING FILTERS OR SUB —FIELD SYSTEM FLUSHING. THE DRIP PANEL MICROPROCESSOR MAY LOG AND RECORD FOR LATER RETRIEVAL CYCLES DOSED BY ZONE AND ANY ALARM CONDITION. RAIN SENSOR SHALL DEACTIVATE PUMPING TO FIELD WHEN IT "SENSES RAIN." THE MAIN PUMP CONTROL PANEL SHALL INCLUDE, BUT NOT BE LIMITED TO, AN "AUTO/MANUAL" SYSTEM CONTROL SWITCH, STOP/START SWITCH FOR EACH PUMP, NON—RESETTABLE ELAPSED TIME RECORDER FOR EACH PUMP, AND INDIVIDUAL PUMP RUN LIGHTS. THE MAIN PUMP CONTROL PANEL SHALL BE A NEMA 4X ENCLOSURE. ALL SUPPORTING CONTROL UNITS, IF NOT HOUSED WITHIN THE MAIN PUMP CONTROL PANEL, SHALL BE IN A SEPARATE NEMA 4X ENCLOSURE. 1-1/4" SCH. 40 PVC RETURN FROM FIELDS EL. ±318.3' 1,250 GALLON SEPTIC TANK El El rc-P] E—Z TREAT POD FILTER INV.EL. ±319.2' INV.EL. BYPASS ±318.1' O INV.EL. 318.0' 1,000 GALLON E—Z TREAT RECIRCULATION TANK 4" SCH. 40 PVC LEGEND FORCE MAIN GROUND — — — GRAVITY LINE FLOW DIRECTION IN- 1-1/4" SCH. 40 PVC SUPPLY TO ZONE 1 1-1/4" SCH. 40 PVC SUPPLY TO ZONE 2 1-1/4" SCH. 40 PVC SUPPLY TO ZONE 3 -1/4" SCH. 40 PVC RETURN LINE FROM ZONE 1 & 2 GROUND EL. ±320.0' INV.EL. UV 3,600 GALLON DOSING/STORAGE TANK 4" SCH. 40 PVC TREATMENT SYSTEM SCHEMATIC / PROFILE HYDRAULIC — UNIT ZONE VALVES TO ZONES 1,2AND3 HIGHEST POINT ON IRRIGATION FIELD = ±318.0' LEGEND ADJACENT BOUNDARY BOUNDARY PROPERTY \ \ \\ \��� \\ \\ CONTOURS — INDEX CONTOURS — INTERMEDIATE \ \ \ \ \ \ \\ / — — DRAIN FIELD (SEPTIC) AREA \\\ \\ o �\ \ E ELECTRIC LINE x EXISTING FENCE WL WETLANDS EDGE OF PAVEMENT 100 YEAR FLOOD PLAIN \8 0 X M�T�' � � �� � �� � I � � \ EXISTING STREAM 0 \ I �I \ \ \ \ \ INITIAL DRIP LINES (FLAGGED) EXISTING \ I `� \ \ '------------------ 0 INITIAL DRIP LINES (UNFLAGGED) \ v A v LOT 16 \STRUCTURE \ I I I WHISTLING QUAIL I \ \ \ 1 \' \ \ LOT 91 j RETURN LINES RUN \\ B.M. 2010, PG. \ \ SUPPLY LINES � B.M. 1987, �I \ EXISTING �_ � � ����'� � � � ZONE PUD �CZ � �� PG. 1615 \ \ DIVERSION BERM ZONE RR DWELLING /iEXISTINGI J I \ I L Y � �� ►f BRONZE CHECK VALVE l / POND RETURN MANIFOLD SUPPLY MANIFOLD LOT 16 ci / I —� \ \ \\\22g�� I \ ` CO CLEAN OUT \ \_ � COMMON AREA WHISTLING QUAIL CID CONTROL PANEL RUN W \ \�\ � N B.M. 2010, \ \ I B.M. 1987, \ \ \ o \ � � CDPG. 391 I / I EZRT E-Z TREAT RECIRC. TANK PG. 572 � I \ ZONE PUD—CZ I \ I \ \ //\ 3 F, I \ I \ E—Z E—Z TREAT TREATMENT UNIT ZONE RR V L �SETBACK� i\� \ ���`btxU FDT FIELD DOSING TANK 1 y �� I ST SEPTIC TANK HU HYDRAULIC UNIT zi 325,27;� A� �� / I UV ULTRAVIOLET DISINFECTION —S53 M METER LOT 15 'dl- oo A �\ + o I ZV ZONE VALVE \\ WHISTLING QUAIL a N RUN CD' N A IPF IRON PIPE FOUND V \ \ I \ B.MPG1.g572 CS w J COS / DRIP N \ _ \ POWER POLE '\ z - IRRIGATION \ — ZONE RR 1-4 m ('PROPOSED \ I EXISTING TREE \ / /H DWELLING DRAINFIEL II I 1 \ I \ EZ TREAT �"� a n SYSTEM X N \ COMMON AREA N THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED o `B.M. 201 1 , 0 UPON INFORMATION FURNISHED BY OTHERS. WHILE THIS J 01 I PG. 940 \ / INFORMATION IS BELIEVED TO BE RELIABLE, THE DESIGN — ZONE MD -CZ r / PROFESSIONAL CANNOT ASSURE ITS ACCURACY, AND THUS IS NOT RESPONSIBLE FOR THE ACCURACY OF THIS RECORD 17" W \ I I \ \ `, �\ DRAWING OR FOR ANY ERRORS OR OMMISSIONS WHICH MAY HAVE BEEN INCORPORATED INTO IT AS A RESULT. THOSE RELYING ON THIS RECORD DOCUMENT ARE ADVISED TO OBTAIN LE 3�/ I I I I / APP YINGT FORRIANY POURPOSETS ACCURACY BEFORE \ LOT 14 / / / ' l / WHISTLING QUAIL / / /;LOT 20 I / RECORD DRAWING RUN z WHISTLING QUAIL B.M. 1987, I 1 I \2� N / RUN OCTOBER 21 2019 ZONE RR72 B.M. 1987, j \ \ / _ PG. 1 615 ZONE RR _ GRAPHIC SCALE. 1 100 0 50 100 200 300 REVISIONS N0. DATE DESCRIPTION 500' SETBACK FROM _3 \ PROJECT MANAGER: PROJECT ENGINEER: TREATMENT AND \ \ IRRIGATION \ GSM AVF DRAWN BY: CHECKED BY: \ \\ \ ( \ \ \ \ I I \ JDH GSM DATE: APRIL 12, 2019 J 4 Ma\\OIN IN ELL & Associates, P. C. 1101 NOWELL ROAD, SUITE 118 RALEIGH, NORTH CAROLINA 27607 P.O. BOX 129 LICENSE MORRISVILLE, NORTH CAROLINA 27560 No. C-1039 TEL: (919) 467-1239 FAX: (919) 319-6510 DONALD & REBECCA JOHNSON SURFACE DRIP IRRIGATION E—Z TREAT SYSTEM WAKE COUNTY, NC OVERALL SITE PLAN PROJECT NUMBER I DRAWING NUMBER A69601.00 C-101 x 0 N Q c� 0 0 W a W N W z O a ca 0 W U Q W D N i z O 0 z x O Q U U W m W 0 z O 0 O O O Q A69601.00 - DONALD & REBECCA JOHNSON - SURFACE DRIP IRRIGATION E-Z TREAT SYSTEM 00 N 0 N N U 0 m m 0 0 U 0 0 s M N a 0 0 0 0 0 L 0 7 O co o Q 0 N 4 J N a MAINTENANCE SCHEDULE BASE MAP INFO FROM: SOIL SERVICES, PLLC & WAKE COUNTY GIS PROPERTY SURVEY PROVIDED BY: ISOIL SERVICES, PLLC ITEM FREQUENCY TASK SEPTIC TANK 3 - 6 MONTHS CHECK FOR SOLIDS ACCUMULATION, BASIS OF DESIGN BLOCKAGES, OR BAFFLE DAMAGE, IN/EXFILTRATION, PUMP SEPTAGE. BEDROOMS GPD/BR INITIAL DESIGN FLOW FINAL DESIGN CLEAN EFFLUENT FILTER. FLOW (GPD) REDUCTION FLOW (GPD) 12 MONTHS PUMP OUT ACCUMULATED SOLIDS IF 4 120 480 25% 360 NECESSARY. RECIRCULATION TANK WEEKLY CHECK PUMPS, CONTROLS, ALARMS, FIELD DOSING TANK ELAPSED TIME METERS. TREATMENT TABLE E—Z TREAT PODS REQUIRED: 1 PODS 3-6 MONTHS CHECK FOR SOLIDS ACCUMULATION, E—Z TREAT RE —CIRCULATION RATIO: 6 TIMES ADF IN/EXFILTRATION. TOTAL E—Z TREAT FLOW PER DAY: 2646 GALLONS E—Z TREAT RE —CIRCULATION CYCLES PER DAY: 78 CYCLES 12 MONTHS PUMP OUT ACCUMULATED SOLIDS IF E—Z TREAT VOLUME PER DOSE: 34 GALLONS NECESSARY. RE —CIRCULATION TIMER ON: 2.5 MINUTES RE —CIRCULATION TIMER OFF: 16.0 MINUTES SUPPLY LINES, FORCE MAINS 6-12 MONTHS CHECK FOR EXPOSED PIPE AND RE —CIRCULATION DOSE CYCLE: 18.5 MINUTES LEAKAGE. DENITRIFICATION GALLONS RETURNED: 778 GALLONS/DAY DENITRIFICATION RETURN SETTING: 4 GPM DISTRIBUTION FIELDS 2-4 WEEKS MOW VEGETATIVE COVER IF APPLICABLE. E-Z TREAT SURFACE AREA: 29 SQUARE FEET CHECK FOR EROSION, OR PONDING OF E—Z TREAT LOADING RATE: 17 GPD/SQUARE FOOT 3-6 MONTHS EFFLUENT. PUMPS, FILTER SYSTEM, MONTHLY CHECK FLOW METER READOUT AND GEOFLOW FIELD DOISNG TABLE & DISTRIBUTION PIPING COMPARE TO RECORDED FLOWS, NUMBER OF DOSES PER DAY/ZONE: 2 DOSES/DAY CHECK PUMPS AND FILTER SYSTEM TIMER ON. PUMP RUN TIME PER DOSE/ZONE: 9.17 MINS:SECONDS FOR LEAKS. TIMER OFF. PUMP OFF TIME BETWEEN DOSES: 11:50 HRS:MINS PER ZONE — PUMP RUN TIME PER DAY/ZONE: 0:18 HRS:MINS QUARTERLY REMOVE FILTER COVERS AND INSPECT ALL ZONES — NUMBER OF DOSES PER DAY / ALL ZONES: 6 DOSES/DAY FOR ACCUMULATION OF DEBRIS. CHECK ALLOW TIME FOR FIELD TO PRESSURIZE: 0:00:30 HRS/MINS/SECS DIFFERENTIAL PRESSURE GAUGE FILTER FLUSH TIMER: 0:00:20 HRS/MINS/SECS BEFORE AND AFTER FLUSHING (D.P. DRAIN TIMER: 0:05:00 HRS/MINS/SECS SHOULD RETURN TO ORIGINAL FIELD FLUSH TIMER: 0:01:00 HRS/MINS/SECS OPERATING D.P.) CHECK PUMPS FOR FIELD FLUSH COUNTER: 42 CYCLES ABNORMAL VIBRATION, TEST THE ALARM TIMER REQUIRED TO COMPLETE ALL FUNCTIONS PER DAY: 1:36 HRS:MINS FUNCTIONS. IDOSE VOLUME PER ZONE: 1 60 GPD SEMIANNUALLY REMOVE AND LUBRICATE O-RINGS ON FILTER CANISTER, REPLACE IF DAMAGED, CLEAN 1-1/2" FILTER SCREEN AT HYDRAULIC UNIT. EFFLUENT LIMITS PER 15A NCAC 02T .0605 CARBONACEOUS BIOCHEMICAL OXYGEN DEMAND (CBOD): 1<30 MG/L ANNUALLY REMOVE FILTER SCREEN AND REPLACE, TOTAL SUSPENDED SOLIDS (TSS): 1<30 MG/L CLEAN USED FILTER SCREEN IN MILD AMMONIA NITROGEN — NH3—N 1<15 MG/L ACID SOLUTION AND STORE FOR NEXT FECAL COLIFORM: <200 /too ML ANNUAL REPLACEMENT, FLUSH FIELD SUPPLY AND RETURN MANIFOLDS BY REMOVING (UNSCREWING) AIR/VACUUM BREAKERS. E-Z TREAT TREATMENT MONTHLY INSPECT CONTROL/ALARM PANEL, SYSTEM PUMPING SYSTEM EFFLUENT FILTERS/PUMP SCREENS, PROCESSING TANK, AND E-Z TREAT POD FILTER. (TREATMENT UNIT) AN N UALLY CHECK AND/OR REPLACE BATTERIES IN FLOW METER. (IF APPLICABLE) ULTRAVIOLET DISINFECTION 3-6 MONTHS WIPE (CLEAN) UV LAMPS. UNIT CHECK INTENSITY AND REPLACE LAMP WHEN REQUIRED. IPS / NEW PROPERTY LINE \ I � I I 100' WELL VV SETBACK WELL DRIP LINE SEGMENTS (ZONE 1) LINE # LENGTH LATERAL # LENGTH TOTAL 1 153' 1 2 153' 1 306' 3 153' 2 4 152' 2 305' 5 150' 3 6 150' 3 300' 7 151' 4 8 151 ' 4 302' 9 150' 5 10 150' 5 300' TOTAL DRIP LINE LENGTH OF ZONE 1 1,513' DRIP LINE SEGMENTS (ZONE 2) LINE # LENGTH LATERAL # LENGTH TOTAL 11 149' 1 12 149' 1 298' 13 149' 2 14 149' 2 298' 15 148' 3 16 147' 3 295' 17 145' 4 18 144' 4 289' 19 144' 5 20 144' 5 288' TOTAL DRIP LINE LENGTH OF ZONE 2 1,468' DRIP LINE SEGMENTS (ZONE 3) LINE # LENGTH LATERAL # LENGTH TOTAL 21 144' 1 22 144' 1 288' 23 144' 2 24 146' 2 290' 25 146' 3 26 146' 3 292' 27 142' 4 28 138' 4 280' 29 132' 5 30 126' 5 258' TOTAL DRIP LINE LENGTH OF ZONE 3 1,408' NOTES 1. THE DRAINFIELD SHALL BE HAND CLEARED TO REMOVE SMALL TREES AND UNDERBRUSH. LARGER TREES WILL REMAIN IN PLACE. 2. BLANK TUBING SHALL BE SPLICED INTO THE DRIP TUBING TO WORK AROUND LARGE TREES. 3. TANKS SHALL BE SETBACK A MINIMUM 5' FROM DWELLING (15' IF THERE IS A BASEMENT). 4. DRAIN ALL ROOF AND TOE DRAINS AWAY FROM TREATMENT SYSTEM COMPONENTS AND DRIP FIELD. 5. CLEAR DRAIN FIELD AREA OF VEGETATION WITH HYDRO AXE AND SAVE MULCH WITH EXISTING GRADE. 6. INSTALL DRIP TUBING ON SURFACE WITH LANDSCAPE STABLES. PLACE MULCH ON TOP OF FIELD. -- --- / 7. MAY PLANT VEGETATION BETWEEN LINES. 8. ALL DRIP LINES, TREATMENT AND STORAGE UNITS SHALL BE A MINIMUM OF 50' FROM PROPERTY LINE EXCEPT WHERE THERE IS A WRITTEN AGREEMENT FOR / \ WAIVER FROM ADJACENT LANDOWNER. / I X 9. ALL DRIP FIELD COMPONENTS SHALL BE ENCLOSED IN / I N WIRE FENCE WITHIN THE REQUIRED SETBACKS. SOME 1 COMPONENTS SHOWN OUTSIDE FOR CLARITY. / (D o N X N/ �-�D N/ /I I I I EIP TOTAL DRIP LINE LENGTH 4,389' I N ZD 325.27 IPS \ / / I \ N n S 88°53' 19" E \ / 0I — — 12.5' REVIEW BOUNDARYLd z1 — 25' TREATMENT SETBACK _ — — 29 30 �I \ I (WITH WAIVER) \ Q w + 27 28'If ilf w I � � N � 23 24 � \ I \ \ �1 22 \ .� � � I 1 I I I Y 1-1/2" SCH 40 PVC + � I � � / SUPPLY MANIFOLD (TYP) �- 19 20` o m \ / ZONE 3 I WO D FENCE \ z w / 1-1/2 SCH 40 PVC + 17 18 I I \ m �' / RETURN MANIFOLD (TYP) I \ I \ m � // 1-1/4" SCH 40 1 6 \ I f �ET Lu w PVC SUPPLY /14NAIL AT BASE' \ � (TYP. OF 3) \ 0 o / I OF DIPTURBED EIS 1-1/4" SCH 40 12 \ z / PVC RETURN 9 \ I \ i PROPOSED o N \ / HOUSE INv I i FFE=f328' co \ I I I I I \ I I -- ---- /--- ---------------- PROPOSED ZV HU O FDT 0� CPS —� EZRT O ( E—Z ST 4" SCH. 40 PVC FROM HOUSE Lel 10 ZONE 2 1 + 5 8 \ 3 6 1 4 \ \ \ I UV ZONE 1 I I \ 1-1/4" PVC RETURN + y I \ FROM FIELD — _ L0 C_ x�X \ I L0 r7 DRIVEWAY + I o ------------- - - - - - - - - - - - - - - \ - / — — — — 50' TREATMENT SETBACK _ \ -- REVIEW BOUNDARY AT / MIDWAY POINT BETWEEN COMPLIANCE BOUNDARY �� DIVERSION BERM \ AND WASTE BOUNDARY PER \ 15A NCAC 02L .0108 \ \ I I — — — — _ 25' REVIEW BOUNDARY COMPLIANCE BOUNDARY AT PROPERTY LINE PER PREVIOUSLY PERMITTED WIRE FENCE \ 15A NCAC 02L .0107 (i) SUITABLE SOILS BOUNDARY ENCAPSULATING (WHITE STORE SOILS) WETTED AREA \ EIP 303.55' \ EIP N 88*53' 1 7" W EIP LEGEND — — ADJACENT BOUNDARY BOUNDARY (PROPERTY) CONTOURS - INDEX CONTOURS - INTERMEDIATE — — DRAIN FIELD (SEPTIC) AREA E ELECTRIC LINE x EXISTING FENCE WL WETLANDS — EDGE OF PAVEMENT 100 YEAR FLOOD PLAIN — — EXISTING STREAM INITIAL DRIP LINES (FLAGGED) ------------------ INITIAL DRIP LINES (UNFLAGGED) RETURN LINES SUPPLY LINES DIVERSION BERM 04 BRONZE CHECK VALVE 0 RETURN MANIFOLD ® SUPPLY MANIFOLD CO CLEAN OUT CID CONTROL PANEL EZRT E-Z TREAT RECIRC. TANK E-Z E-Z TREAT TREATMENT UNIT FDT FIELD DOSING TANK ST SEPTIC TANK HU HYDRAULIC UNIT UV ULTRAVIOLET DISINFECTION M METER ZV ZONE VALVE IPF IRON PIPE FOUND POWER POLE EXISTING TREE THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED UPON INFORMATION FURNISHED BY OTHERS. WHILE THIS INFORMATION IS BELIEVED TO BE RELIABLE, THE DESIGN PROFESSIONAL CANNOT ASSURE ITS ACCURACY, AND THUS IS NOT RESPONSIBLE FOR THE ACCURACY OF THIS RECORD DRAWING OR FOR ANY ERRORS OR OMMISSIONS WHICH MAY HAVE BEEN INCORPORATED INTO IT AS A RESULT. THOSE RELYING ON THIS RECORD DOCUMENT ARE ADVISED TO OBTAIN INDEPENDENT VERIFICATION OF ITS ACCURACY BEFORE APPLYING IT FOR ANY PURPOSE. RECORD DRAWING OCTOBER 21 2019 GRAPHIC SCALE: 1 " = 20' 0 10 20 40 60 REVISIONS NO. DATE I DESCRIPTION I PROJECT SMMANAGER: PROJECTAVF ENGINEER: I DRAWN BY: CHECKED BY: JDH GSM DATE: APRIL 12, 2019 04 I SEAL - _' 1M1 \ D +�lellil1517,, ��/Z MacCONNELL & Associates, P. C. 1101 NOWELL ROAD, SUITE 118 -- RALEIGH, NORTH CAROLINA 27607 P.O. BOX 129 LICENSE MORRISVILLE, NORTH CAROLINA 27560 No. C-1039 TEL: (919) 467-1239 FAX: (919) 319-6510 DONALD & REBECCA JOHNSON SURFACE DRIP IRRIGATION � 1 E-Z TREAT SYSTEM WAKE COUNTY, NC � SYSTEM LAYOUT CXJ IPS PROJECT NUMBER A69601.00 DRAWING NUMBER C-102 0 cV O 0 0 0 W a W N I W z 0 a 0 W Q W D N I z 0 0 Z 0 Q U U W m W 0 Q z 0 0 O O O Q A69601.00 - DONALD & REBECCA JOHNSON - SURFACE DRIP IRRIGATION E-Z TREAT SYSTEM R EFFLUENT BYPASS VALVE BY E-Z TREAT 4 4" FROM FILTER POD 4" SCH. 40 PVC CROSS (TYP.) 4" SCH. 40 PVC FLOAT BALL 7'-3-1/2" (TYP.) FINISHED GRADE 4" 90' BEND o o FLOW CONTROL o WEIR 4 4" TO SPRAY NOZZLE WATER LEVEL PLATE ULTRAVIOLET CL o (TYP.) DISINFECTION v o UNIT T o ALL TANKS REQUIRE A 6" 12" THICK STONE BASE (TYP.) d ° 1 �:1 �:1�:1 �:1:�:1 �:1 �:1 a:1 r:1:r:r:r:1 10 95, D-101 / NTS 0 77 PRESSURE 3/4" CAP (TYP.) L — — — — — o o o 0 UGE 1 1/2" BALL VALVE V 4" SCH. 40 PVC 90' ELBOW (TYP.) 3/4" TRU-UNION BALL VALVE II ----------------------- CLEAN I I I II I CLEAN OUT ,--, -� OUT 4" SCH. 40 PVC DAVID BRANTLEY & SONS C + 1,250 GALLONS SEPTIC TANK O° tO i ST-322 OR APPROVED EQUAL I I \ to t0 EFFLUENT SEPTIC FLOW —► �`� �'� FILTER �'� FLOW FILTER SERVICE 24"0 E-Z SET RISER W/COVER HANDLE (TYP. UNLESS OTHERWISE NOTED) IF BELOW DRIVEWAY OR PARKING LOT THEN USE ONLY H-20 TRAFFIC RATED DEVICES L------------------------ Li------------ 126" 1 0 0 0 0 0 1 2" X 6" BOARD WITH ALUMINUM BRACKETS ATTACHED TO POD WITH S.S. SCREWS TO ASSIST WITH SOIL STABILIZATION (TYP. OF 4) 0 0 0 4" CPP (SEE SITE PLAN FOR OUTLET) 0 0 0 0 0 0 0 0 0 0 o c o D-101 0 wl_li UV CONTROL FIELD DOSING PANEL CONTROL PANEL 0 o E-Z TREAT CONTROL PANEL 1-1/2" SCH. 40 PVC 3/4" SCH. 40 30"0 E-Z SET PVC RECIRC RISER W/COVER LINE SEE GEN. NOTES N 1-1 /2" ELBOW (TYP.) \\\/ PVC 1. FULL UNION (TYP.) 1-1/2- PVC 24 MESH SPIN 3/4„ CHECK VALVE FILTER UNION tFROM PUMP 1-1/2" SCH. 40 PVC LINE TO FILTER POD SPIN FILTER SECTION A D-101 NTS 1 E-Z TREAT POD FILTER SYSTEM I- — — — — —� — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — - 1 30"0 E-Z SET RISER W/COVER --- -- 3/4" SCH. 40 PVC RECIRC. LINE 12" MIN. -- LENGTH --- - - -------- __--_-_-_-_-_-_-_/_--__-___-_-_-_-_-_-_-_--------------_-_-_-_ \ FLEX PVC EFFLUENT BYPASS VALVE ��----� W/FLOW RESTRICTOR TO 10 GPM 4" X 2" REDUCER DAVID BRANTLEY & SONS A , O + + i 1,000 GALLONS RECIRCULATION TANK D-101 i PT 237 OR APPROVED EQUAL i i UV UNIT (SEE 2/D-103 FOR DETAIL) TURBINE PUMP X 2 REDUCER SPIN FILTER 1-1/2" SCH. 4" " 40 PVC BALLI CHECK VALVE (TYP.) I 95" li 00 r- SLOTTED DRAIN PIPE BEDDING (TYP.) c E-Z TREAT POD SECTION D-101 NTS 3' ALL AROUND F ELECT BACKFILL REE OF DEBRIS 30"0 E-Z SET RISER W/COVER TURBINE PUMP DAVID BRANTLEY & SONS �i TRAFFIC -RATED + i 3,600 GALLONS FIELD DOSING/STORAGE TANK i PT-H2O-3896 OR APPROVED EQUAL FLOAT TREE (TYP.) 167" — J NOTES 1. SEE C-101 FOR GENERAL NOTES. 2. CAST INLET AND OUTLET BOOTS ARE REQUIRED FOR ALL TANKS. 3. ALL RISER LIDS SHALL HAVE SS TAMPER RESISTANT BOLTS. 4. ALL PIPING SHALL BE SCH 40 PVC UNLESS OTHERWISE NOTED ON PLANS. ALL PVC PIPES SHALL BE BURIED A MINIMUM OF 3 FEET UNLESS SHOWN OTHERWISE. 5. SEPTIC TANKS SHALL BE CONSTRUCTED WITH A BAFFLE WALL DIVIDING THE TANK INTERIOR 2/3rd TO 1/3 rd. THE BAFFLE WALL SHALL BE CONSTRUCTED TO PERMIT PASSAGE OF EFFLUENT THROUGH A SLOT OR HOLES LOCATED BETWEEN 45 AND 55 PERCENT OF THE INTERIOR DEPTH. 6. ALL TANKS SHALL HAVE A MINIMUM 28-DAY CONCRETE STRENGTH OF 4,500 PSI. 7. TANKS SHALL MEET REINFORCING REQUIREMENTS TO ACCOMMODATE 300 POUNDS PER SQUARE FOOT. EITHER STEEL REINFORCING WIRE, REBAR OR APPROVED FIBER MAY BE USED. 8. ALL JOINTS (MID -SEAM, TOP -SEAM) SHALL BE SEALED USING CONCRETE SEALANTS BUTYL SEALANT # CS-102 MEETING ASTM C-990. 9. TANKS SHALL BE LEAK -TESTED PRIOR TO SYSTEM START UP BY APPLYING A VACUUM OF 5-INCHES OF MERCURY WITH RISER ASSEMBLIES IN PLACE OR A 24-HOUR STATIC WATER TEST, IN ACCORDANCE WITH ASTM STANDARDS. 10. ALL PIPE PENETRATIONS THROUGH PRECAST CONCRETE TANKS SHALL BE PRESS -SEAL CAST -A -SEAL 402 RUBBER BOOTS AND GROUTED. 11. CONTRACTOR MAY USE LARGER TANKS. 12. MAXIMUM COVER OVER NON H-20 TANKS SHALL BE 30". 13. ALL SERVICE ACCESS OPENINGS WILL BE A MINIMUM OF 24 INCHES. EXCEPTIONS MAY BE MADE ON A CASE BY CASE BASIS WITH E-Z TREAT'S PRIOR WRITTEN APPROVAL. ALL ACCESS OPENINGS SHALL BE FITTED WITH E-Z SET RISER ASSEMBLIES. SERVICE ACCESS OPENINGS FOR THE RECIRCULATION CYLINDER SHALL BE A 30-INCH OPENING AND FITTED WITH AN E-Z SET 30-INCH RISER ASSEMBLY. TRAFFIC RATED TANKS SHALL HAVE CONCRETE RISERS. 14. NON -CONCRETE TANKS SHALL NOT BE USED IN CONJUNCTION WITH THE E-Z TREAT SYSTEM WITHOUT PRIOR WRITTEN APPROVAL BY E-Z TREAT. 15. THE FILTER POD INVERT OUT SHALL BE A MINIMUM OF 6" ABOVE THE INVERT IN OF THE RECIRCULATION TANK OR 1/4-INCH PER FOOT SLOPE, WHICHEVER IS D GREATER D-101 THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED UPON INFORMATION FURNISHED BY OTHERS. WHILE THIS INFORMATION IS BELIEVED TO BE RELIABLE, THE DESIGN PROFESSIONAL CANNOT ASSURE ITS ACCURACY, AND THUS IS NOT RESPONSIBLE FOR THE ACCURACY OF THIS RECORD TO HYDRAULIC DRAWING OR FOR ANY ERRORS OR OMMISSIONS WHICH MAY UNIT HAVE BEEN INCORPORATED INTO IT AS A RESULT. THOSE RELYING ON THIS RECORD DOCUMENT ARE ADVISED TO OBTAIN INDEPENDENT VERIFICATION OF ITS ACCURACY BEFORE APPLYING IT FOR ANY PURPOSE. RECORD DRAWING OCTOBER 21 2019 REVISIONS NO. DATE I DESCRIPTION I PROJECT S�MANAGER: PROJECTAVE ENGINEER: I DRAWN BY: 1 CHECKED BY: JDH IGSM 1 SEPTIC, RECIRCULATION, AND FIELD DOSING/STORAGE TANKS DATE: D-101 NTS ALARM LIGHT Fmffim NO/ PVC 24"0 E-Z SET RISER RISER W/CO ER ��CONTROL PANEL CHE/K"VALVE 1 �170 9 W/COVER (TYP. UNLESS LOCATED WITHIN „ OTHERWISE NOTED) PRECAST CONCRETE 10-FEET OF TANKS ��• DIRECT BURY '.,'9y.....p DONUT (OPTIONAL) . -1✓ .; NOTE: FIELD VERIFY PRIOR (TYP-) G / 3 4 SCH. 40 1-1 2" SCH. 40 PANEL „ CABLE TO AFLEX TO ORDERING RISERS � z � / : � / / j to PVC RECIRC. LINE to PVC FULL UNION x X 3/4" a DIRECT BURY MacCONNELL PVC \j/ / ° / /// CABLE TO PANE / \\BALL \\ \\ \\ ° / / / / /\/ / / / / / / / / / / / / / / / /\/\/\/ \\j\\j\ /\VALVE SSOC1ateS/" 71715511411141111-1 /2 PVC �/\/\ / �/ // /CHECK VALVE / / / \ \ \ \ \ \ \ \ \ \ \ \ \ \ao \ \ \ \ \ \ \ \ \ \ \ \ \ \ \\\\AFLOAT TREE \ \/\/\/\/\/\/ \ \ \ \ \ \ \ \,\ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ 1101 NOWELL ROAD, SUITE 118 \\ \\\\\ N \\\\\ \\\\\\\\\\\\\\\\\\\ ////////////////.////////, //1BRACKEf i//// _ " /\\/\/\/ 9 \//� \�/j�/j�/\ ---------- \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ ____ ____ ° \\ j\ j\ j\ j\/ j\/\/\/\/\/\/\ \ ___________ ° o ° o ° p _ 3 4__ _ / / \� ° ___________ / ° / / / / / //a, a / / / / / / / / / / / / / _ __ _ / /\/ RALEIGH, NORTH CAROLINA 27607 ///// \\\\\\\ UNION / PVC FULLUNION° ° \/\ P.O. BOX129 ° ° D D \� / \\/\\/ \ \ \ ° 2" VENT�� �4 SCH. ;\\j\\ \\/\\/\\/\\/\\/\\ ° - // (TYP.) FLOAT TREE BRACKET /\\/�� LICENSE MORRISVILLE, NORTH CAROLINA 27560 Al, PVC\\//\\ \ \//%//%//%//%/ EFFL ENT BYPASS o0 " ° \// NO. C-1039 TEL: 919 467-1239 FAX: 919 319-6510 \ \ \ \ \ f VALVE BY E-Z TREAT HIGH WATER ALARM=8 FROM TOP 3/16"ANTI-SIPHON ( ) ( ) WATER LINE / HOLE (TYP.) E O 1-1/2" SCH. 40 PVC SECONDARY TIMER 1-1/2 SCH. DONALD &REBECCA LINE TO FILTER POD - 40 PVC TO NOTE: UV UNIT NOT N N HIGH WATER ALARM HYDRAULIC UNIT J O H N S O N 4" SCH. 40 PVC SHOWN FOR - DROP TEE (TYP.) CLARITY. SEE DOSE ENABLE=21 " ABOVE FLOOR CAST -A -SEAL DETAIL 2, D-107 - 402 RUBBER N r iv POLYLOK PL-68 EFFLUENT o x 3/16 BOOT (TYP.) iv `n z FILTER, ZABEL A1800, DOSE ENABLE N RESIDENTIAL EFFLUENT FILTER R M - HOLE (TYP) - PUMP OFF=18 ABOVE FLOOR SURFACE DRIP IRRIGATION a -H P/N 170-0078, OR ENGINEERS SEE RECIRCULATION MERCURY FLOAT n i*4 PUMP OFF 3 APPROVED EQUAL TANK SECTION SWITCHES (2) 6" - - E-Z TREAT SYSTEM C > in i� o DETAIL THIS SHEET F MERCURY FLOAT � -H 3' -H 00 SWITCHES (4) ° 3„ 1-1 /2" SCH. 40 3" ^ 1-1 /2" SCH. 40 6- WAKE PVC FLOAT TREE PVC FLOAT TREE WAKE COUNTY, N C 12' ° MIN. (TYP.) d d a C 0 1 /3 TANK LENGTH I STA-RITE HIGH HEAD 3" PVC STAND STA-RITE HIGH HEAD MULTI -STAGE 3" PVC STAND 9 r� �� ALL TANKS REQUIRE A MULTI -STAGE SUBMERSIBLE SUBMERSIBLE EFFLUENT PUMP CATALOG DETAILS - 1 Of 3 6 THICK #57 STONE EFFLUENT PUMP CATALOG NUMBER STEP 30-15221 (1/2 HP) X)BEDDING (TYP.) NUMBER STEP 30 4 HP D SEPTIC TANK, RECIRCULATION TANK, AND FIELD DOSING/STORAGE TANK SECTIONS D-101 NTS PROJECT NUMBER DRAWING NUMBER CD A69601.00 D-101 J 0 N O c� 0 U Ld w U) r a w m F- N I w z 0 a 2 m 0 w U m D U) I z 0 Z 0 7 Q U U w m w 0 a z 0 0 I 0 0 0 Q 3601.00 - DONALD & REBECCA JOHNSON - SURFACE DRIP IRRIGATION E-Z TREAT SYSTEM wz El .r =ATED 4"x 4" 1. POSTS TO BE PLACED ±20' O.C. TWO STRAND WIRE FENCE NTS PVC REDUCING ELBOW LTC 600 DRIP TO DRIP" PVC SLIP TO BLANK TUBING 4 D-102 2 D-102 MANIFOLD TRENCH MINI -CLICK RAIN SENSOR CONTROLLER NOTE: 1. DO NOT COVER. 2. RAIN SENSOR SHALL BE MODEL MINI-CIK BY HUNTER RAIN SENSOR NTS NOTE: 1. SUPPLY OR RETURN MANIFOLD PIPE SIZES MAY VARY (SEE DISTRIBUTION _ FIELD PLAN DETAIL) z CONNECTION TO 1/2" J"xj" PVC REDUCING PE DRIPPER LINE ELBOW (TYP. OF 2) z / WELL PACKED EMITTER TUBING LAID ON ~� EARTHEN DAM EXISTING GRADE m ry z_ N � _ N LTC 600 DRIP TO DRIP LOCKSLIP COUPLING 1/2" PVC RETURN - 1/2" PE BLANK TUBING MANIFOLD DRIPPER LINE CONNECTION NTS NOTE: 1. PIPING TO BE 4" SCH. 40 PVC. s GRAVITY CLEANOUT D-102 NTS CONCRETE (OPTIONAL) 5 D-102 MANIFOLD TRENCH 12" WIDTH MIN. WELL PACKED EARTHEN DAM 1/2" PVC SUPPLY 1 Tr. DIVERSION BERM DETAIL NTS 4" - 6" TYPICAL DAM HEIGHT 12" BEYOND MANIFOLD TRENCH TO DRIPPER LINE CONNECTION 1/2" PE BLANK TUBING (TYP.) SUPPLY / RETURN SECTION NTS -2"-4" OF PINESTRAW OR MULCH (OPTIONAL) EMITTER TUBING /_ 8° TUBING STAPLES 25' O.C. LTC 600 DRIP TO DRIP LOCKSLIP COUPLING `- ORIGINAL GRADE -ED SOIL NOTES i��`l���lil�af•`Z�III[�iI�P►I�7�III[�iI���I�1<�I�I��L'1��N>f��•`� THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED UPON INFORMATION FURNISHED BY OTHERS. WHILE THIS INFORMATION IS BELIEVED TO BE RELIABLE, THE DESIGN PROFESSIONAL CANNOT ASSURE ITS ACCURACY, AND THUS IS NOT RESPONSIBLE FOR THE ACCURACY OF THIS RECORD DRAWING OR FOR ANY ERRORS OR OMMISSIONS WHICH MAY HAVE BEEN INCORPORATED INTO IT AS A RESULT. THOSE RELYING ON THIS RECORD DOCUMENT ARE ADVISED TO OBTAIN INDEPENDENT VERIFICATION OF ITS ACCURACY BEFORE APPLYING IT FOR ANY PURPOSE. RECORD DRAWING OCTOBER 21 2019 REVISIONS NO. DATE DESCRIPTION IPROJECT AVF TMANAGER: PROJECT ENGINEER: I DRAWN BY: CHECKED BY: JDH GSM DATE: APRIL 12, 2019 _ SEAL - 17OrO ler�+t 11[1141�///Z/� MacCONNELL & Associates, P. C. 1101 NOWELL ROAD, SUITE 118 RALEIGH, NORTH CAROLINA 27607 P.O. BOX 129 LICENSE MORRISVILLE, NORTH CAROLINA 27560 NOTE: NO. C-1039 TEL: (919) 467-1239 FAX: (919) 319-6510 1. SEE SITE PLAN FOR ORIENTATION. FIELD RETURN LINE (SEE DONALD & REBECCA \ SITE PLAN FOR PIPE SIZE) J O H N S O N Rs 041s AG`' REDUCER SURFACE DRIP IRRIGATION CLEAN c REDUCER E-Z TREAT SYSTEM OUT 4" PVC WAKE COUNTY, NC TO SEPTIC TANK PVC END CAP 4" PJAJVC 4" PVC WYE TEE 7 FIELD RETURN LINE DETAIL DETAILS - 2 of 3 D-102 NTS PROJECT NUMBER DRAWING NUMBER A69601.00 D-102 w U) r a w N w z O_ H Q C7 0 w U Q w In I z O In z 2 O a U U w m w 0 J Q z O 0 O O O Q A69601.00 - DONALD & REBECCA JOHNSON - SURFACE DRIP IRRIGATION E-Z TREAT SYSTEM ^z V r C 7 r Cu 9 V 6 C5 C 0 n NOTES 1007 4" WELL CAP BACKUP DISCONNECT 1. SEE SHEETS C-101 AND D-101 FOR GENERAL NOTES. NOTE. PRIMARY LAMP LAMP UNION (TYP.) 4" 2" 2" 4" NOTES: 1. NUMBER OF LATERALS TO MATCH SITE 0 CONDITION. CAP FITTINGS NOT NEEDED. 1. ULTRAVIOLET LIGHT PURIFIER UV-102 BY E—Z TREAT. 2. ALL PIPE SHALL BE SCH. 40 PVC UNLESS 4' x 2 »" 4" x 2" OTHERWISE INDICATED. REDUCER REDUCER 2• PROVIDE DUAL GFI RECEPTACLE 1 /2" BALL FOR UNIT AND HEAT TAPE. FIELD 3. SEE SITE PLAN FOR NUMBER OF VALVE ROUTE 2—#12,1—#12G, IN 3/4" FINISH GRADE LATERALS. FINISH GRADE PVC CONDUIT TO 120 VOLT V�%��A %�AA� SINGLE PHASE 20 AMP BREAKER 4. SEE SITE PLAN FOR SUPPLY LINE, RETURN AT HOUSE. SCADER VALVE ROUND VALVE BOX HR LINE, AND MANIFOLD SIZES. ROUND VALVE BOX SCHRADER VALVE 1" THREAD DIAMETER 5. AIR VACUUM BREAKER VALVES SHALL BE 1" THREAD DIAMETER TOP VIEW 3. ORIENTATION PER SITE REQUIREMENTS. AIR/VACUUM 1" PVC UTILITY BALL INSTALLED ON EACH SUPPLY AND RETURN AIR/VACUUM 1" PVC UTILITY BALL BREAKER (AVBK-1) VALVE W/ THREADED MANIFOLD AT THE HIGH POINT. BREAKER (AVBK-1) VALVE W/ THREADED 4. INSTALL 1/2" BALL VALVE FOR ENDS (NORMALLY OPEN). ENDS (NORMALLY OPEN). f CONTROL SAMPLING DOWNSTREAM OF U.V. WITH ALARM UNIT. 1" SCH. 80 PVC NIPPLE 1" SCH. 80 PVC NIPPLE LENGTH AS REQUIRED BRICK LENGTH AS REQUIRED BRICK SUPPORTS 5. MAY LOCATE IN RECIRCULATION SUPPORTS (THREE) TANK IF ACCESS PROVIDED. (THREE) 1-1/2" SCH. 40 PVC MANIFOLD 1-1 /2" TEE (TYP) 1-1 /2" TEE (TYP) PEA GRAVEL SUMP 2"x2"x1 /2" PEA GRAVEL SUMP �� 1-1/2- SCH. 40 PVC MANIFOLD 1-1/2" ELBOW REDUCING TEE 1-1/4" SUPPLY LINE 1-1/4" RETURN LINE 1-1/2 x 1/2" 1-1/2" BRONZE CHECK VALVE 1-1/2" x 1/2" REDUCER BUSHING REDUCER BUSHING 1-1/2" x 1-1/4" REDUCER 1/2" SCH. 40 PVC RETURN 1/2" SCH. 40 PVC RETURN 1-1/2" x 1" REDUCING TEE 4 2 2 4„ LATERAL (TYP. OF 4) � LATERAL (TYP. OF 4) (SOC X FIPT) SUPPLY RETURN 4" x 2" REDUCER 1/2" BALL 4" x 2" i VALVE REDUCER 30" DIA. z; E—Z SET DISCONNECT SUPPLY / RETURN ZONE HEADER RISER UNION (TYP.) PRIMARY 100% D3 NT$ LAMP BACKUP LAMP z NON —CORROSIVE 1 REFLECTIVE AND PROTECTIVE SLEEVE NOTES: 1. REMOVE WOODY VEGETATION UNDER 2" CALIPER. 2. INSTALL DRIP LINES AT 3' ON CENTER. USE LANDSCAPE STAPLES AS NECESSARY TO SECURE DRIP LI N ES. 3. COVER WITH 2"-4" OF PINESTRAW OR MULCH (OPTIONAL). LANDSCAPE STAPLES AS NECESSARY 3' O/C DRIP LINES z PVC MAINLINE ifl 1-1/ REDU FF NATIVE SOIL i�\�\�\�\ ��������������\ FILTER FI IPS FLEX SLOPE FILTER Al FLUSH LI RETURN 1 SEPTIC T) 3 DRIP FIELD SEPTIC LINES PVC R /EDI PVC I FIELD FLI �O3NTS 30" RISE SEE SCHEDU LOOPING OF NON DRIP BLANK TUBING 1/2" BLANK (NON DRIP) LINE (66" MIN. TOTAL LENGTH) 1/2" / "LINE � 6" RAD. MIN. (TYP) LTC 600 DRIP TO DRI I 1.5' LOCKSLIP COUPLING TYP. LOOP CONNECTION TO RETURN MAIN -SUPPLY ZONE HEADER TO ALTERNATE LATERALS (6,7, OR 8) SUPPLY MANIFOLD DRIPPER LINE CONNECTION 1/2" PE TUBING WITH 0.53 GPH EMITTERS 0 2. 0' O.C. z NOTES: r6 1. TYPICAL ALL DISTRIBUTION FIELDS LOOPED LATERALS 0 3.0' FT. O.C. 2. SUPPLY AND RETURN LINES TO BE PLACED IN THE SAME TRENCH. 4 DISTRIBUTION FIELD PLAN TYPICAL D-103 J NTS RETURN ZONE HEADER TO ALTERNATE LATERALS (6,7, OR 8) RETURN 1/2" RETURN LINE TO ZONE RETURN HEADER NOTES: 1. METER CAN BE INSTALLED IN SEPARATE RISER. SECTION VIEW '2 ULTRAVIOLET DISINFECTION D-103 J NTS PVC \IAIAII IAIC TOP VIEW TOP VIEW SECTION VIEW SECTION VIEW 5 HYDRAULIC UNIT D-103 NTS ZONE 3 VALVE ZONE 2 VALVE ZONE 1 VALVE TO DRIP ZONES 1-1/4"x1" PVC REDUCER (TYP. ZONES 1-3) 1-1/4" SUPPLY LINE (ZONES 1, 2&3) THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED UPON INFORMATION FURNISHED BY OTHERS. WHILE THIS INFORMATION IS BELIEVED TO BE RELIABLE, THE DESIGN PROFESSIONAL CANNOT ASSURE ITS ACCURACY, AND THUS IS NOT RESPONSIBLE FOR THE ACCURACY OF THIS RECORD DRAWING OR FOR ANY ERRORS OR OMMISSIONS WHICH MAY HAVE BEEN INCORPORATED INTO IT AS A RESULT. THOSE RELYING ON THIS RECORD DOCUMENT ARE ADVISED TO OBTAIN INDEPENDENT VERIFICATION OF ITS ACCURACY BEFORE APPLYING IT FOR ANY PURPOSE. RECORD DRAWING OCTOBER 21 2019 REVISIONS NO. DATE DESCRIPTION I PROJECT S�MANAGER: PROJECTAVE ENGINEER: I DRAWN BY: JDH CHECKED BY: GSM DATE: APRIL 12, 2019 17069 4� MacCONNELL & Associates, P. C. 1101 NOWELL ROAD, SUITE 118 RALEIGH, NORTH CAROLINA 27607 P.O. BOX 129 LICENSE MORRISVILLE, NORTH CAROLINA 27560 NO. C-1039 TEL: (919) 467-1239 FAX: (919) 319-6510 DONALD & REBECCA JOHNSON SURFACE DRIP IRRIGATION E-Z TREAT SYSTEM WAKE COUNTY, NC DETAILS - 3 of 3 y PROJECT NUMBER DRAWING NUMBER A69601.00 D-103 J 0 N 0 0 0 w F- V) r a w F- N w z 0 H Q c� a_ 0 w U D (n Z 0 0 z x 0 0 U U w m w 0 J Q z 0 0 0 0 0 Q 69601.00 — DONALD & REBECCA JOHNSON — SURFACE DRIP IRRIGATION E—Z TREAT SYSTEM V V D i 0 0 0 D D D� ELECTRICAL SPECIFICATIONS 1. THREE DIFFERENT CONTROL PANELS WILL CONTROL THE WASTEWATER SYSTEM. ONE CONTROLS THE PRETREATMENT, ONE CONTROLS THE FINAL DISPERSAL AND ONE CONTROLS THE ULTRAVIOLET DISINFECTION. CONTRACTOR MAY USE A COMBINED PANEL. 2. EACH PANEL SHALL BE APPROXIMATELY 13" WIDE X 15" HIGH AND IS A NEMA 4X, UL RATED ENCLOSURE. THE PANELS SHALL BE SUPPLIED BY THE SYSTEM DISTRIBUTOR. 3. THE PANELS SHALL BE MOUNTED BY THE ELECTRICIAN WITHIN 10' OF THE TANK UNITS. THEY SHALL BE MOUNTED NEXT TO EACH OTHER AND 48" - 60" OFF THE FINISHED GRADE TO THE BOTTOM OF THE ENCLOSURE. 4. THE BUILDER'S ELECTRICIAN SHALL MAKE THE INTERNAL PANEL CONNECTIONS OF THE PUMP AND CONTROL CORDS. EACH CONTROL PANEL SHALL CONTAIN A WIRING SCHEMATIC IDENTIFYING ALL TERMINAL CONNECTIONS. THE SYSTEM INSTALLER SHALL BUNDLE AND MARK EACH CORD WITH THE APPROPRIATE IDENTIFICATION AND SECURE IN THE ACCESS RISER AT THE DIFFERENT PUMP POINTS. 5. THE DUPLEX TIME DOSE CONTROL PANEL REQUIRES DEDICATED CIRCUITS OF 20 AMPS, 230 VOLTS, SINGLE PHASE SUPPLIED FOR EACH PUMP. 6. THE PRETREATMENT CONTROL PANEL REQUIRES A DEDICATED CIRCUIT OF 20 AMPS, 230 OR 115 VOLTS, SINGLE PHASE SUPPLIED FOR THE PUMP. 7. THE PRETREATMENT CONTROL PANEL REQUIRES A DEDICATED CIRCUIT OF 15 AMPS, 115 VOLTS SUPPLIED FOR THE ALARM / CONTROL SIDE OF THE PANEL. 8. THE PRETREATMENT CONTROL PANEL REQUIRES A TELEPHONE EXTENSION LINE FROM THE DWELLING FOR THE RMSYS TELEMETRY SYSTEM. THIS IS NOT A DEDICATED LINE; IT IS AN EXTENSION FROM ANY LINE THAT IS USED IN THE DWELLING. 9. THE FINAL DISPERSAL CONTROL PANEL REQUIRES A DEDICATED CIRCUIT OF 20 AMPS, 230 OR 115 VOLTS, SINGLE PHASE SUPPLIED FOR THE PUMP. 10. THE FINAL DISPERSAL CONTROL PANEL REQUIRES A DEDICATED CIRCUIT OF 20 AMPS, 115 VOLTS SUPPLIED FOR THE ALARM / CONTROL SIDE OF THE PANEL. 11. A MINIMUM CONDUIT SIZE OF 1 1/2" SHALL BE FURNISHED AND INSTALLED BE THE ELECTRICIAN AS A CONNECTION BETWEEN EACH CONTROL PANEL AND THEIR RESPECTIVE TERMINATION POINTS OUT IN THE TANK AREA. 12. ALL OPEN CONDUIT ENDS SHALL HAVE REMOVABLE CLAY TYPE DUCT SEAL EMBEDDED TO PREVENT GASES AND MOISTURE FROM ENTERING THE CONTROL PANELS. DO NOT USE PERMANENT SILICONE OR EXPANDABLE FOAM PRODUCTS. 13. ALL PUMP AND FLOAT CONTROL CORDS SHALL BE SUPPLIED WITH EITHER 30' OR 50' LEADS. THIS WILL HELP KEEP SPLICES TO A MINIMUM AND SHOULD BE AVOIDED IF AT ALL POSSIBLE. IF A SPLICE MUST BE USED, IT MUST BE MADE ABOVE GRADE IN A PLASTIC NEMA 4X JUNCTION BOX. 14. ALARMS SHALL BE AUDIBLE AND VISUAL. ALARMS SHALL ACTIVATE AUTO DIALER TO RMSYS SYSTEM. 15. AUDIBLE/VISIBLE ALARMS SHALL BE EXTERNAL TO ANY STRUCTURE. 16. PROVIDE MANUAL TRANSFER SWITCH AND PLUG FOR PORTABLE EMERGENCY GENERATOR. PROVIDE DISCONNECT PER NCBC AND NEC. Branch Circuit Protection Device/Disconnect Means Field Provided - PUMP size per manufacturing specifications for pump/motor Incoming Power 120/230 VAC, 50/60HZ PUMP LOAD G L1 1-2/N 120/230 VAC, 0-16 AMPS, 50/60 HZ I I L3 T3 PUMPS MUST CONTAIN INTEGRAL THERMAL OVERLOAD PROTECTION! GL T2j T2 L2 �® fGROUNDLUG \� e� Tj 1 C B1 20A M1 OUND TO CONTROL Incoming Power 120 VAC, 50/60HZ L1 N 1 1 CB2 110A 11CR1 14 1 TD11 3 °OFF FS2 -Timer Enable a-- Irr-0------� TB3 TB4 AUTO 7 D1 2 FS3 - High Alarm T135 T136 Al R A2 lc�FS1 - Low Alarm TB1 TB2 Al R1 I® ALARM BEACON �� R 21 CR1 22 11 12 11 CR2 14 SW2 CR3 14 Al Test Silence F1, F2 FUSE MUST BE DREPLACED WITH 1 AMP 5mmX20mm TYPE FAST ACTING 250 V MAX. This control panel is for timed dosing applications. When the timer enable float is up, the timer will start timing for the duration of the "Off' time and when complete, the pump will start for the duration of the "On" time. Both Off and On times are adjustable. This pattern repeats until the timer enable float lowers and turns off. The Low float acts as a redundant off and will also activate the alarm. If the level reaches the High float switch, the alarm will activate. TB1 TB2 T133 TB4 T135 T136 �°l Ice FS3 - High FS1 - Low FS2 - Level Level Timer Enable A2 Float Switch Field Wiring *FS1 - Normally Open, Narrow Angle *FS2 - Normally Open, Wide Angle *FS3 - Normally Open, Narrow Angle -- FIELD WIRING FIELD SUPPLIED TERMINAL BLOCK TB Power Wiring = BLK 120VAC Control Wiring = RED Neutral = WHT Ground = GRIN TIGHTENING AWG/ OR TORQUE IN INCH CIRCULAR PQUNDS MILL SIZE SCREW EXTERNAL DRIVER DRIVE WRENCH 14 35 75 12 35 75 10 35 75 8 40 75 6 45 110 4 45 110 2 50 150 1 50 150 110 50 80 2/0 50 80 LEGEND OR CONTROL RELAY CB CIRCUIT BREAKER GL GROUND LUG Swl HOA SWITCH SW2 TEST/SILENCE SWITCH R ALARM BEACON B ALARM BUZZER Ml MAGNETIC CONTACTOR G1 PUMP RUN INDICATOR GL GROUND LUG FS FLOAT SWITCH TD1 Repeat Cyde Tmer Off H rs On O 6 8 Off R 10 12 Scale Min ® R- On On To set the timer, use a screwdriver to change timer Scale (0-12 most common). Use a screwdriver to change the "On" time increments (minutes most common). Use a screwdriver to change the "off' time increments (hours most common). Turn the dial with the Red line to the desired "On" time (this example is 2 minutes). Turn the dial with the Green line to the desired "Off' time (this example is 4 Hours). Notes: 1. WARNING! Electrical Shock Hazard! Disconnect power before servicing this product. A qualified service person must install and service this product according to applicable electrical and plumbing codes. 2. Install in accordance with National Electric Code, NFPA 70, Seal all boxes, fittings and conduit with appropriate seal devices to prevent moisture and gases from entering enclosure. 3. Connect all grounds to a good ground. 4. Dashed lines represent field wiring - Use minimum 60 deg C Copper Wire 5. Branch Circuit Protection Device/Disconnect Means Field Provided. E-Z TREAT SIMPLEX CONTROL PANEL NTS Terminal Connections CONTROL PUMP Incoming Power Incoming Power 120 VAC, 50/60HZ 120/230 VAC, 50/60HZ L1 N I I L1 1-2/N TB1 TB2 T133 T134 TB5 T136 0� 6) K� F pl FS3 - High FS1 - Low FS2- Level Level Timer Enable Float Switch Field Wiring *FS1 - Normally Open, Narrow Angle *FS2 - Normally Open, Wide Angle *FS3 - Normally Open, Narrow Angle PUMP Connection I O v c00 VC C Z Z O� C -A �0 NOTES: 1. PANEL BY ALDERON, OR EQUAL. 2. PANEL TO BE SUPPLIED BY E-Z TREAT. 3. CONTRACTOR MAY USE COMBINED E-Z TREAT / FIELD DOSING PANEL WITH LIKE FUNCTIONS. From Main Power Panel 230/115 VAC, 1 Phase, 60 Hz. Main disconnect provided by others. 1.1 Ground Wire 1.2 L2' •,,,,.� 1.3 L1 N N 1.4 See page 2 for Power Wiring Options. -- 1.5 1.6 1.7 1 8 High Level 5 Alarm 1'9 2 Secondary m Timer 5 a On&ON 1.10 1.11 o Timer 5 On & Off 1.12 a Redundant in Off & Low 5 Level Alarm 1.13 1.14 1.15 1.16 1.17 1.18 PUMP ETM & CT 1.19 SIGNAL 1.20 1.21 1.22 TRANSFORMER 1.23 115V-24V 40VA 1.24 FUSE 2A GEOFLOW SUBSURFACE DRIP SYSTEMS 1-800-828-3388 Panel Wiring Diagram Model GE04-Sim-Aut fT~ L2I CB 20A M1 = Factory Wire = Field Wire PUMP 16A MAX Note: Motor must have internal overload protection SURGE ARRESTOR SCHNEIDELE SDSA1175T LOGO SIEMENS 6ED1-052-1 FB00-0BA8 MOTOR CONTACTOR ABB AX18-30-10-84 LEVELALARM LIGHT SIEMENS 3SUI SERIES AUDIBLE ALARM FLOYD BELL SP-1081 ALARM SILENCE RELAY [DEC RJ2S-CL-A120 REMOTE ALARM 1AHW OR 15 VAC ALAORM) EDW-WD-GEO-21 Rev. 2.0 © 05/17/17 Page 1 of 2 2A 2.2 2.3 2.4 2.5 2.6 2.7 2.8 2.9 2.10 2.11 2.12 2.13 2.14 2.15 2.16 2.17 2.18 2.20 2.21 2.22 2.23 2.24 2.25 2.26 2.27 2.28 \ \ \ \ VORTEX FILTER ------------------------------ \ \ HAND OFF AUTO ` 6 • 7 VORTEX FILTER 24VAC VALVE \ \ PROVIDED BY OTHERS \ Q3 \ \ \ \ \ SYSTEM FLUSH \ \ \ \ HAND OFF AUTO \ ` SYSTEM FLUSH 8 - 9 24VAC VALVE \ \ \ \\ PROVIDED BY OTHERS \ 04 \ \KN � ` LOGO \ EXPANSION \ L1 n_ � From DMB SIEMENS L_I�� \ \ \ \ 1.23 ZONE 1 VALVE 6ED1-055-155-1 FBFB00-OBA2 \ \ HAND OFF AUTO ZONE\ IVALVE \ �yF 24VAC \ PROVIDED BY OTHERS 01 \ \ (05) \ \ \ \ \ ZONE 2 VALVE \ S HAND OFF AUTO I ZONE2 12 ... 13 24VAC VALVE 02 PROVIDED BY OTHERS V (06) N ;-i I-`, \ \ \ \ \ ZONE 3 VALVE ` S HAND OFF AUTO \at ���� 14 .,,•,.. 15 ZONE3 24VAC VALVE \ \ PROVIDED BY OTHERS 03 \ (07) \ �1 �; \ \ ZONE 4 VALVE \ \ HAND OFF AUTO \ � I I ZONE 16 -- - 17 24VAC VALVE ` Oq \ PROVIDED BY OTHERS \(OB) \ CLASS 2 WIRING Float Arrangement Diagram 4 4 a El F High Level 4 Alarm Secondary Timer On & Off 4 Timer On & Off Redundant Off & Low Level Alarm NOTE: All valves must be NORMALLY CLOSED. *Power Wiring Options: 230VAC Pump 115VAC Pump 0000 O 0000 O 0000 0000 � Ittt 0000 N Lt A B N Lt A B 3 3 0 a a 3 3 0 O O D 0 0 N N N N r� Z a Zr ZE c m m m 1. PANEL BY GEOFLOW, MODEL GE04-SIM-AUT, OR EQUAL. 2. PANEL TO BE SUPPLIED BY E-Z TREAT. 2� 3. CONTRACTOR MAY USE COMBINED E-Z TREAT /FIELD FIELD DOSING CONTROL PANEL DOSING PANEL WITH LIKE FUNCTIONS. E-101 / NTS EDW-WD-GEO-21 Rev. 2.0 © 05/17/17 Page 2 of 2 NOTES 1. SEE SHEETS C-101 AND D-101 FOR GENERAL NOTES THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED UPON INFORMATION FURNISHED BY OTHERS. WHILE THIS INFORMATION IS BELIEVED TO BE RELIABLE, THE DESIGN PROFESSIONAL CANNOT ASSURE ITS ACCURACY, AND THUS IS NOT RESPONSIBLE FOR THE ACCURACY OF THIS RECORD DRAWING OR FOR ANY ERRORS OR OMMISSIONS WHICH MAY HAVE BEEN INCORPORATED INTO IT AS A RESULT. THOSE RELYING ON THIS RECORD DOCUMENT ARE ADVISED TO OBTAIN INDEPENDENT VERIFICATION OF ITS ACCURACY BEFORE APPLYING IT FOR ANY PURPOSE. RECORD DRAWING OCTOBER 21 2019 REVISIONS NO. DATE DESCRIPTION IPROJECT AVF TMANAGER: PROJECT ENGINEER: I DRAWN BY: JDH CHECKED BY: GSM DATE: APRIL 12, 2019 MacCONNELL & Associates, P. C. 1101 NOWELL ROAD, SUITE 118 - ` RALEIGH, NORTH CAROLINA 27607 P.O. BOX 129 LICENSE MORRISVILLE, NORTH CAROLINA 27560 NO. C-1039 TEL: (919) 467-1239 FAX: (919) 319-6510 DONALD & REBECCA JOHNSON SURFACE DRIP IRRIGATION E-Z TREAT SYSTEM WAKE COUNTY, NC ELECTRICAL DETAILS 1 OF 1 V L A69601.00 - DONALD & REBECCA JOHNSON - SURFACE DRIP IRRIGATION E-Z TREAT SYSTEM PROJECT NUMBER DRAWING NUMBER A69601.00 E-101