HomeMy WebLinkAboutNC0000108_Compliance Evaluation Inspection_20191021DocuSign Envelope ID: 76828798-744B-4FB8-BCEB-47CF49D8C68A ROY COOPER_ CiO.ernOr a K41CHAEL S. RECAN p. ; Seererary LINDA CULPEPPER NORTH CAROLINA cuwtor Environmental Quality October 21, 2019 Craig Hillyer, Plant Manager New Excelsior Inc 1379 Old Rosman Hwy Brevard, NC 28712 SUBJECT: Compliance Inspection Report New Excelsior WWTP NPDES WW Permit No. NC0000108 Transylvania County Dear Permittee: The North Carolina Division of Water Resources conducted an inspection of the New Excelsior WWTP on 10/11/2019. This inspection was conducted to verify that the facility is operating in compliance with the conditions and limitations specified in NPDES WW Permit No. NC0000108. The findings and comments noted during this inspection are provided in the enclosed copy of the inspection report entitled "Compliance Inspection Report". The following item of significance was noted at the time of the inspection: It is recommended that the facility consider connecting to the adjacent Town of Rosman sewer lift station, decommissioning their wastewater treatment facility and rescinding their NPDES permit. This will eliminate the operation and maintenance costs associated with an aging facility and the environmental liability associated with an NPDES permit and discharge. If you should have any questions, please do not hesitate to contact me with the Water Quality Regional Operations Section in the Asheville Regional Office at 828-296-4500 or via email at tim.heim@ncdenr.gov. Sincerely, DocuSigned by: 082B1105A3CA418_.. Tim Heim, P.E., Environmental Engineer Water Quality Regional Operations Section Asheville Regional Office Division of Water Resources, NCDEQ ATTACHMENTS Ec: WQS-ARO Server LF G:\WR\WQ\Transylvania\Wastewater\Minors\Excelsior 00108\Inspections\2019 CEI\20191021_NC0000108_CEI.Rtf North CaroiibsDepart rnentofEovironmerttalQuality I DiNsionofWater Resourres Ashevil ie Regional Office 1 2090 U.S_ 70 Htg3nray I Swan nanos. North Carolina 23773 '� 328 2M-4500 DocuSign Envelope ID: 76828798-744B-4FB8-BCEB-47CF49D8C68A United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN 1 2 15 I 3 I NCO000108 111 12 I 19/10/1, I17 18 I S J 19 L G] 201 I 211111 I I I I I I II I I I I I I I I I I I I I I I I I I I I I I I II I I I I I f6 Inspection Work Days Facility Self -Monitoring Evaluation Rating 131 QA ---------------------- Reserved ------------------- 671 70 I I 71 I I 72 I r I u ty 73 I I 174 751 I I I I I I I80 I I i Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES oermit Number) 01:OOPM 19/10/11 16/05/01 New Excelsior WWTP 1379 Old Rosman Hwy Exit Time/Date Permit Expiration Date Rosman NC 28772 02:OOPM 19/10/11 20/09/30 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data Davis Allen James/ORC/828-697-0063/ Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Craig Hillyrd,1379 Old Rosman Hwy Brevard NC 28712//828-885-2929/8288846121 Yes Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Operations & Maintenance 0 Facility Site Review 0 Effluent/Receiving Waters Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Timothy H Heim DWR/ARO WQ/828-296-4665/ 10/21/2019 F.Sii ea by: MON" 6'im Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date ooasig-d by: 1 10/ 2 1/ 2 019 p�� )I' — EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# DocuSign Envelope ID: 76828798-744B-4FB8-BCEB-47CF49D8C68A NPDES yr/mo/day Inspection Type (Cont.) NC0000108 I11 121 19/10/11 117 18 JCJ Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Tim Heim of the Asheville Regional Office performed a routine Compliance Evaluation Inspection of the facility on October 11, 2019. Craig Hillyer (Plant Manager) and plant maintenance staff assisted with the inspection. The plant appeared to be operating adequately during the inspection, but many components have reached the end of their design life and are potentially in need of repair/replacement. It is recommended that the facility consider connecting to the adjacent Town of Rosman sewer lift station, decommissioning their wastewater treatment facility and rescinding their NPDES permit. This will eliminate the operation and maintenance costs associated with an aging facility and the environmental liability associated with an NPDES permit and discharge. Page# DocuSign Envelope ID: 76828798-744B-4FB8-BCEB-47CF49D8C68A Permit: NC0000108 Owner - Facility: New Excelsior WWTP Inspection Date: 10/11/2019 Inspection Type: Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? 0 ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ❑ ❑ ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: The plant appeared to be operating adequately during the inspection, but many components have reached the end of their design life and are potentially in need of repair/replacement. Aeration Basins Yes No NA NE Mode of operation Ext. Air Type of aeration system Diffused Is the basin free of dead spots? 0 ❑ ❑ ❑ Are surface aerators and mixers operational? ❑ ❑ 0 ❑ Are the diffusers operational? 0 ❑ ❑ ❑ Is the foam the proper color for the treatment process? 0 ❑ ❑ ❑ Does the foam cover less than 25% of the basin's surface? 0 ❑ ❑ ❑ Is the DO level acceptable? ❑ ❑ ❑ Is the DO level acceptable?(1.0 to 3.0 mg/1) ❑ ❑ ❑ Comment: Visible steel comDonents of the aeration basin are showina sianificant deterioration. rust and holes. Disinfection -Tablet Yes No NA NE Are tablet chlorinators operational? 0 ❑ ❑ ❑ Are the tablets the proper size and type? 0 ❑ ❑ ❑ Number of tubes in use? 2 Is the level of chlorine residual acceptable? ❑ ❑ ❑ Is the contact chamber free of growth, or sludge buildup? 0 ❑ ❑ ❑ Is there chlorine residual prior to de -chlorination? 0 ❑ ❑ ❑ Comment: The chlorinator chamber and lid appeared in poor condition and tablets were being inserted adjacent to the tablet sleeves to achieve contact treatment. De -chlorination Yes No NA NE Type of system ? Tablet Is the feed ratio proportional to chlorine amount (1 to 1)? 0 ❑ ❑ ❑ Is storage appropriate for cylinders? ❑ ❑ 0 ❑ # Is de -chlorination substance stored away from chlorine containers? ❑ ❑ 0 ❑ Page# 3 DocuSign Envelope ID: 76828798-744B-4FB8-BCEB-47CF49D8C68A Permit: NC0000108 Owner - Facility: New Excelsior WWTP Inspection Date: 10/11/2019 Inspection Type: Compliance Evaluation De -chlorination Yes No NA NE Comment: Are the tablets the proper size and type? ❑ ❑ ❑ Are tablet de -chlorinators operational? ❑ ❑ ❑ Number of tubes in use? 2 Comment: The de-chlor chamber and lid appeared in poor condition and tablets were being inserted adjacent to the tablet sleeves to achieve contact treatment. Effluent Pipe Is right of way to the outfall properly maintained? Are the receiving water free of foam other than trace amounts and other debris? If effluent (diffuser pipes are required) are they operating properly? Comment: Yes No NA NE ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ❑ ❑ ■ ❑ Page# 4