Loading...
HomeMy WebLinkAboutWQ0037076_Sewer Extension Permit Status Update_20191016 { of Hee :' 4p---- .4. 1 0 7 issi October 16, 2019 Mr. Nyle L Hothem Environmental Engineer I —PERCS Unit North Carolina Department of Environmental Quality Division of Water Resources RECEIVED 1617 Mail Service Center, Room 925T Raleigh, NC 27699 OCT $ B Subject: City of Mebane Sewer Permit Certification Request Project Plastic—NCIC (Cambro—Public Gravity Sewer) NCDEQIDWRJNPDES Mebane, NC Mr. Hothem, Please find the attached sewer certification update in response to your recent request. The project in question includes: Permit No. Issue Date Facility County WQ0037076 10/22/14 Cambro—Public Gravity Sewer Alamance • Permit Status—Attached are approved plans from the design engineer, an as-built exhibit provided by the City of Mebane, and engineers certification. The as-built exhibit provides field collected data that includes sewer length, pipe type, invert elevations, and manhole top elevation of the section of sanitary sewer and manhole owned by the City of Mebane. Please let me know if there is anything else needed to finalize this certification. Sincerely, 4/1/------ Franz K. Holt, PE Mebane City Engineer CITY OF MEBANE 106 East Washington Street I Mebane,NC 27302 0 (919)563 5901 fholt@cityofmebane.com CITY MEBANE . COM ENGINEERING CERTIFICATION Permittee: City of Mebane Permit No: WQ0037076 Project Name: Project Plastic - NCIC (Cambro - Public Gravity Sewer) This project shall not be considered complete nor allowed to operate in accordance with Condition 7 of this permit until the Division has received this Certification and all required supporting documentation,which includes: • One copy of the project construction record drawings(plan&profile views of sewer lines&force mains)of the wastewater collection system extension. Final record drawings should be clear on the plans or on digital media (CD, DVD, or flash drive) and are defined as the design drawings that are marked up or annotated with after construction information and show required buffers,separation distances,material changes,etc. Permit modifications are required for any changes resulting in non-compliance with this permit. A detailed description for partial certifications should be attached to this form along with any certification comments. Certification should be submitted in a manner that documents the Division's receipt. The Permittee is responsible for tracking all partial certifications up until a final certification is received. PERMITTEE'S CERTIFICATION I, the undersigned agent for the Permittee, hereby state that to the best of my knowledge, this project has been constructed pursuant to the applicable standards&requirements,and the Professional Engineer below has provided applicable design/construction information to the Permittee,and the Permittee is prepared to operate&maintain the wastewater collection system permitted herein or portions thereof. Thvi.S.Cheek• C: r ( t 15 Printed Name,Title Si nature Date ENGINEER'S CERTIFICATION Josh Johnson , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe ([1] periodically, ❑ weekly, ❑ full time) the construction of the project name and location as referenced above for the above Permittee hereby state that,to the best of my knowledge,due care and diligence was used in the observation of the construction of the subject permit, such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 02T;the Division of Water Resources' (Division)Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable;the Division's Minimum Design Criteria for the Fast-Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; as well as the project plans,specifications,and other supporting materials as subsequently filed and approved. 111I!If// North Carolina Professional Engineer's Seal w/signature&date: � ��: • ,• ti.( • ww-- Final ❑ Partial(include description) -,- a rof � 3370 `OM G t" Notes/Qualifiers: /// sitk inil i O Send the Completed Form&Supporting Documentation to the Following Address: NCDEQ/DWR WATER QUALITY SECTION PERCS UNIT By U.S.Postal Service: By Courier/Special Delivery: By Email: 1617 Mail Service Center 512 N.Salisbury St.Suite 925 Nyle.Hothem@ncdenr.gov Raleigh,NC 27699-1617 Raleigh, NC 27604 # _ ' `» r + w EXISTING ;' '" > F `ii 4 SANITARY SEWER MANHOLE ° i. i° � �'�-ter -'_, � • '' ��r t /�� r�� '' x j TOP: 651.65 ' /r v GC #._ r jl} sue... INV IN: 640.17 INV OUT: 640.07 .t' c 'Al,:- " , 1 . .... i ri y q 0 z % - 4. / t SANITARY SEWER 0 V ! i R , _ , AS BUILT S ri } i 4` TOP: 65207 . .-- 1 a' 4 . t • + 7 _,l tr.IINV OUT: 641.13 i LAli * PROJECT PLASTIC ` SANITARY SEWER w 4 i 't. AS-BUILT • (CAMBRO MANUFACTURING) : »,. ` IF` °r - 8"DUCTILE IRON PIPE • s s 4y � j7r _ 10i)-' ' - - Clq I- ':.� :'' ,• :a 4 s. rs p _ ,.< ', THIS EXHIBIT MAP IS TO SERVE AS RECORD DRAWINGS FOR THE IDENTIFEID !t t __ r , ,., .;: « 'SANITARY SEWER AS-BUILT'ONLY INFORMATION INSIDE OF THESE LABELS ARE i _ , ,,j THE ONLY RECORDED ELEVATIONS.LENGTH,AND SLOPES '� ° yt jj# ' ' ALL AERIAL PHOTOGRAPHY,UTILITIES.PARCELS,AND OTHER BOUNDARYS t ',,,^ WERE REPRODUCED FROM ALAMANCE/GUILFORD COUNTY GIS FILES. -' WHILE ALL EFFORTS ARE MADE TO ENSURE ACCURACIES.ALL LOCATIONS Legend ARE APPROXIMATE ALLEY WILLIAMS CARMEN 8 KING.INC o- ASSUMES NO RESPONSIBILITY FOR INACCURACIES WITH THIS DATA, - SSWf-8in _. s: 5 a o f "e& WQ0037076 DRAWN BY: SBM sy CHECKED BY FKH Mebane Manholes . rm ,.-a•"'s � CITY OF MEBANE cAMVIT DA7E:,0�UU3/ZUi9 ■ • Mebane Limits .•• T" PUBLIC GRAVITY SEWER DRAWING FILE: \���� .... ///"� i inch=200 feet • - T.17010/Sewer/Certikaoons