Loading...
HomeMy WebLinkAboutWQ0041157_Application (FTSE)_20190905� ° Cv,,c F1i. ( �- a -51 1 State of North Carolinadj((i �� Department of Environmental Quality DWR Division of Water Resources I5A NCAC 02T.0300-- FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Division of Water Resources FTA 04-16 & SUPPORTING DOCUMENTATION Application Number:y QI}0 J /' (to be completed byDWR)All items must be c2mulefed or the allaicstlion YAII be returned I. APPLICANT INFORMATION: 1. Applicant's name:: Town of ifolly_Snrines (company, municipality. IIOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑ Gcncral Partnership ❑ Privately -Owned Public l'tiliq ❑ federal ❑ StateCounty ® Municipal ❑ Other 3. Signature authority's name: Kendra D. Parrish_ P_1. per I iA NCA C 021' .01(60) Title. Director ofFnginccrin� 4. Applicant's mailing address' 128 South Main Street City: Holly Spring State: hK Zip: 27540- 5. Applicant's contact in formation; Phone number: (9L) ,477- r)3 Grail Address: kerldn. a� .hollyspringsnc.us CL-_J S4"r g co �NALAS 1 " nC, li$ 11. PROJECT INFORMATION: I. Project name: Steeplechase Phase 1 2. Application! Project status- ❑x Proposed (New Permit) ❑ Existing Permit. -Project If a modification, provide the emsting permit number: WQOO and issued date: If new construction but part of master plan, provide thec�asting permit number: WQ00 C C� v 3. County where project is located: Wake re W O 4. Approximate Coordinates (Decimal Degrees): Latitude_ 35'37'04"N Longitude: 78'61'30"W d, CU N M 5. Parcel ID (if applicable): 0648101232, 0647194601. 0648203307 o tri ,O (or Parcel ID to closest downstream sewer) �> I W � � III. CONSULTANT INFORMATION: c I.t! " 1. Pro lcssional Engin eer:Curti%Blaxicr, PE 1_icense Number: 033840 m v firm. McAdams Company ca U Mailing address; 2905 Mendian Parkway z City: Durham State' NC Zip: 27713 Phone number: 919.361-5000 1. - , _ Gntall Address' 6latier(ri1mcaJamsca cam 1V. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. facility Name: Utley Creek Wastc%vatcr Treatment Plan Permit Number: NCO063096 Owner Name- Tmw _ofl-lolly Sorines V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): I. Permit Number(s): WQ0 4 05 Downstream (Receiving) Sewer Sire: _L inch System Wide Collection System Permit Number(s) (if applicable): WQCS—12— (honer Name(s): I: O RM : FTA 04-16 Pape I o f 3 VL GENERAL REQUIREMENTS I. If the Applicant is a Privately -Owned Public Utility, has a Certificate ol'Public Convenience and Necessity been attached'? ❑ Yes ❑ No ❑x N'A 2. If the Applicant is a Developer of lots to be sold, has a Operational Agreement f['()RM� D been attached? ❑ Yes ❑No XIN. A 3. If the Applicant is a flhv ' ti i • n tl 1 =O I ()A been attached? ❑ Yes ❑ No [9 N.-'A 4. Origin ofwaslewater: (check all that apply): BX Residential Owned El Retail (stores, centers, malls) ❑ Car Wash Residential Leased ❑ Retail with food preparation/service ❑ Ilo(el and/or Motels ❑ School / preschool / day can; ❑ Medical / dental / veterinary facilities ❑ Swimming Pool /Clubhouse ❑ Food and drink [aeilitics ❑ Church ❑ Swimming PooUl-ilter Backwash ❑ Businesses /ofiiccs / factories ❑ Nursing [ionic: ❑ Other (lExplain in Attachment) 5. Nature of wastewater: t00 %Donxstic/Commercial °•oCommercial % Industrial (See, 15A NCAC 02T .0103120)) :Is there a Pretreatment Program in effect? ❑ Yes ❑ No 6. Has a [low reduction been approved under I5A NCAC 021- .01140 ? R Yes ❑ No D If yes. providen com of flow rt& wtion. apMoval IStler 7. Summarize wastewater generated by project: Fatablishment Type (see 02T.0114(i1) Daily Resign Flow'-' No. of Units Flow SINGLE FAMILY HOME 255 gaV UNIT 30 7,650 C PD gav GPD gal/ GPD gav GI'D gall GPD gav GPD Total 7,65D GPD a See I A NCAC 021-0114(b). (d), (e111) Lind (e)(2) fbr caveats to wastewater design flow rates (i.e., minimum flow per dwelling: proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south oreastofthc Atlantic Intracoastal Waterway to be used as vacation rentals as defined in CLS. 42A4). b Per 15A NCAC 021' .0114(c), design flow rates for establishments not identified tin table 15A NCAC 027 01141 shall be determined using available flow data. water using l areas, occupancy or operation patterns, and other measured data. 8. Wastewater generated by pmjcct:7,650GPD (per 15A N['.\(' 02f .0114) / i Do not include lbturc flows orprc:viously permitted allocations VVV If permitted flow is zero. indicate why: ❑ Pump Station orCGavity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number: ❑ Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (E.,plain): FORM: FTA 04-16 Page 2 oF5 VIL GRAVITY SEWER DESIGN CRITERIA (lf Applicable) - 02T.0305 & 3IDC (Gravity Se%%yrs): I. Summarize gravity serer to be permitted: Size(inches) Length (feet) Material 8 2,451 PVC 8 788 DIP t i Section II & III of the MDC for Permitting of Gravity Severs contains information related to design criteria :- Section III contains information related to minimum slopes for gravity scwcr(s) > Oversizing lines to meet minimum slope requirement is not allowed and a Iiolation of the MDC Vllfl. PUMP STATION DESIGN CRITERIA (1fApplicable)—02T,0305& ! COMPLETE FOR EACH PUMP STATION INCIAMED IN THIS PROJECT 1. Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitude: Longitude: - 3. Design flow of the pump station: millions gallons per day (firm capacity) 4. Operational point(s) of thcpump(s): —gallons perminuteat fcettotaldynamichcad(fDII) 5. Summarize the lbrec main to be permitted (for this Pump Station)- Size(inches) Length (feet) Material 6. Power reliability in accordance with 15A NCAC 021' .010ifli)f 1): ❑ Standby power sourccorpump with autorrrttic activation and telemetry - 15A NCAC 02* .0305ftl)(B). i Required for all pump stations with an averagedaily flow greater than or equal to 15,000 gallons per day i Must be permanent to I'acility Or if the pump station has an average daily flow less than 15.000 gallons per day: ❑ Portable powersource with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C ) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(hx1)(C): It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (drali ag.rccment) and is compatible with the station. D If the portable powersourecor pump is dedicated to multiple pump stations,an evaluation ofall the pump stations'stoWc capacities and the rotation schedule ofthe portable power sourecor pump, including travel timeframes. shall be provided in the case ol'a multiple station power outage. FORM: FTA 04-16 Page 3 ol'5 IX. SEFBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T.0305(I)): 1. Does the project comply with all separations found in 15A NCAC 021' .010911 &fUl 15A NCAC 02T.0305(f) contains minimum separations that shall be provided 1br sewer systems: ] Yes ❑ No Setback Parameter* Separation Required Storm sewers andother utilities not listed below (vertical) 24 inches Watermains vertical -water over sewer including in benched trenches) 18 inches Watermains (horizontal) 10 feet Reclaimed waterlines (vertical -reclaimed over sewer) 18 inches Reclaimed water lines (horizontal - reclaimed over sewer) 2 feet * *Any private or public water supply source, including any wells. W S-1 waters ofClass I or Class iI impounded reservoirs used as a sourccof drinking water 100 feet **Waters class ified WS (except WS-1 or WS-V), B, SA,ORW, 1-iQW, or SB from normal high water (or tide elevation) and wetlands (sec item IX.2) 50 feet * *Any utherstream, lake, impoundment, or ground water lowering and surface drainage ditches to sect Any building foundation 5 feet Any bus cment 10 feet Top slnpcofcmbankmcnt orcutsof2leetormore vertical height IO Icet Drainage systems and interceptor drains 5 feet Anyswimminp pools 10 feet Final earth grade (vertical) 36 inches i 15A -W'AC 02T.(ti05(Lt contains alternatives where separations in 011'.0305(f cannot be achieved. **Strcam classifications can be identified using the Division's NC StIrfaCe N%r: ierClassificarions weboage > if noncompliance with 02T.030511) or (ILL see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) X❑ Yes ❑ No ". See the Division's draft separation requirements for situations where separation cannot be meet > No variance is required if the alternative design criteria specified is utilimd in design and construction :- As built documents should reference the location of areas of ected 3. Does the project comply with all setbacks found in the river basin rules per 15A NCAC 02B .0200? x❑ Yes ❑ No This would include Trout Buffered Streams per 15A NCAC 213.0202 4. Does the project comply with an individual 404 Permit orany 401 Certifications? Q Yes ❑ No Wetland -related permits shall be requested, obtained, and adhered to Ibr projects that impact wetlands or surface waters D Information can be obtained from the 401 & Buffer Permittino Branch 5. Does project comply with 15A NCAC 02r.0105(c)(6) (additional permits rcertifications)? D Yes ❑ No Per I5A NCAC 02T.0105(c1(5), directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance ofthis permit is contingenton issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines thalarc deemed "high -priority?" Per 15A NCAC 02T.0402, "high -priority sewer" means "any acrial sewer, sewer contacting surface waters, siphon, or server positioned parallel to streambanks that is subject to erosion that undermines ordeteriorates the sewer. DYes ❑ No i If yes, include an attachment with details for each line, including type (aerial line, size. material, and location). High priority lines shall be inspected by the permittee or its representative at leastonce every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permilec's individual S)xtem-Wide Collection permit. FORM: I -TA 04-16 Page 4 o f 5 Ii Id 11ON11fO&M 1. Does the submitted syslcmcomply with 15A N(AC_OZ'[', the 141ininxrnm i?es'gFo i Criteria r floc I'crtnitting of Pummp SlaEions and Farce Mnirms (latest version!. and thr%,ivily ~Crier klininuini. Design Cntena (latest venimm] as applicable' x� Yes ❑ No If No,compicic andsubmit the VariaricciAlternative Design Request application (VADC 10-14) and supportingdocumentsfor review. Approval of the reguest is recruired REiQr1 ti 1 t of lite Fast Track AVOicalion. and-supMriting documents 2. Professional E ngineces Certification. Curti, Vila-iur, PF attest that tilts application for (Professional Engineer's name! from Appltcalion Item IILI ) has been reviewed by = and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting docurnentationto the bestof my knowledge. 1 further aticstthatto the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations. Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Dcsign Criteria for the EastA rack Pennitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package. inclusion of these materials under my signature and seal signifies that 1 have reviewed this rvalcrial and have judged it to be consistent with the proposed design. NOTL - In accordance with General Statutes 143-2:5.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, %hich may include a fine notto exceed $10,000, as wc:l as civil penalties up to S25,000 per violation Forth Carolina Professional F}tgineer's seal, signature, and date: NtCAR OZ�'',� ' a o SEAL 9� 033840 \46- Applicant's Certrficati p/eyr�liA�N}CAC 2•h .0106(b) r 1, V4I i ! f!I / jVh* uttest that this application for (5ibnaturc Authonty s name & titre from Appiion Item 1.3.) has been irviewed by rrx: and is accurate and complete to the best oi' my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge systenito surface waters orthc land %ill result in an immediate enforcement action that may include civil penaltic s, injunctive relief, and orcrinnnal prosecution. I will make no claim against the Division of Water Resources should acondition of this permit be violated. l also understand Ihatif all required parts of this application package are not completed and t hat if all required supporting inforrrmation and attachment.~ are not included, this application package will be returned to = as incomplete. NOTE [n accordance with General Statutes 143-215.6A and 143.215.613, any person who knowingly makes any false statement, representation. or certification in any application package shall he guilty of a Class 2 nusdem:anor, which tr><ty include a fine not to exceed $10,000 as well as civil penalties up to S25,000 per violation. Signature: i6�qco_�� Date 012,710 FOIUYI : F TA 04-I6 Page 5 of 5 W ty.ipk. a w+.. r.. m State of North Carolina Department of Environmental Quality Division of Water Resources Flow Tracking/Acceptance for Sewer Extension Applications (FTSE 04-16) Entity Requesting Allocation: Town Of Holly Springs Project Name for which flow is being requested: Steeplechase Phase 'I More than one FTSE may be required for a single project if the owner of the IVWTP is not responsible for all pump stations along the route of the proposed icaste►rater flow. 1. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Utley Creek Wastewater Treatment Plant b. WWTP Facility Permit #: NC 0063096 All flows are in MGD c. WWTP facility's permitted flow 6.0 d. Estimated obligated flow not yet tributary to the WWTP e. WWTP facility's actual avg. flow 05 f. Total flow for this specific request 0.00 g. Total actual and obligated flows to the facility 3, cl h. Percent of permitted flow used rj(p . 1 • j. 11. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)=(B+C) (E)=(A-D) Design Obligated, Pump Average Daily Approx. Not Yet Total Current Station Firm Flow" Current Avg. Tributary Flow Plus (Name or Capacity, * (Firm / po, Daily Flow, Daily Flow, Obligated Available Number) MGD MGD MGD MGD Flow Capacity*** .-' * The Firm Capacity of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Downstream Facility Name (Sewer); Un ! ih )Qf �PU.ru 064-yip Downstream Permit Number: RAQ OD /may Iq Page 1 of 6 FTSE 04-16 III. Certification Statement: I O�Cfl certify to the best of my knowledge that the addition of the vo ume �of waste ater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and 11 plus all attached planning assessment addendums for which I am the responsible party. Signature of this form indicates acceptance of this wastewater flow. V1 Page 2 of 6 I;TSE 04-16 N STEEPLECHASE USGS TOPO MAP 0 415 830 1,660 PROJECT #: PLT-18000 Feet 1 inch =833,333333Icut HOLLY SPRINGS, NORTH CAROLINA MCADAM ccT State of North Carolina Department of Environment, Health and Natural Resources Division of Environmental Management James B. Hunt, Jr., Governor Jonathan B. Howes, Secretary A. Preston Howard, Jr., P.E., Director March 31,1995 Stepanie L. Sudan, P.E., Town Engineer Town of Holly Springs Post Office Box 8 Holly Springs, North Carolina 27540 RE: Town of Holly Springs Request for Adjusted Daily Wastewater Flow Wake County Dear Ms. Sudn: On March 15,1995, the Division received your wastewater flow reduction request and supporting documentation concerning wastewater flows associated with present residences within the Town of Holly Springs. Your letter requested the Division allow the reduction of wastewater flows from 120 GPD per bedroom as required in required by North Carolina Administrative Code to 255 GPD per household for single family residential units. In support of your request, water consumption data and wastewater information was supplied from households located in Holly Springs. An evaluation was completed by the Division in accordance with 15A NCAC .02190)(3) using the water consumption. data submitted, twelve (12) months of data starting from January 1994. The peak month was determined to be January 1994 based on average wastewater generated per customer. Using the upper 10% of the water consumption data for the month of January, eliminating industries, commercial properties and several inaccurate residential readings, Division staff verified the flow rate of 255 GPD per household. In view of the information submitted, the Division of Environmental Management hereby approves the use of 255 GPD per single family residence in all applicable non -discharge permit applications for future wastewater collection extensions which will be made tributary to the Town of Holly Springs Wastewater Treatment Plant (Permit No. NC0063096). This consideration applies to any applicable future projects submitted to this Division as well as any projects which are presently under review. Wastewater flows presently tributary to the wastewater treatment facilities can be adjusted upon negotiations between the Town of Holly Springs and the Raleigh Regional Office. If you have any questions or comments regarding this matter, please contact Mr. Michael D. Allen at (919) 733-5083 ext. 547. Since y, A. Preston Howard, Jr., P.E. cc: Raleigh Regional Office, Water Quality Section State Engineering Review Group P.O. BOX 29535, Raleigh, North Carolina 27626-0535 Telephone 919-733-7015 FAX,919-733-2496 An Equal opportunity Affirmative Action Employer 50% recycled/ 10% post -consumer paper J M(ADAMS July 12, 2019 NCDENR — DWR Raleigh Regional Office 1628 Mail Service Center Raleigh, North Carolina 27699-1628 RE: Steeplechase Phase 1 Sanitary Sewer System Extension Application Holly Springs, North Carolina PLT-18000 1 81100 1 I AS i 'i TAU— Cs_ W.f; Li I i L:R NC Dept of Environmental Quality sEP - 5 2019 Raleigh Regional Office The accompanied Fast -Track Application (FTA 04-16) includes 2,451 lineal feet of 8" PVC and 788 lineal feet of 8" DIP associated with the proposed Steeplechase Phase 1 development located at 5836 Cass Holt Road in Holly Springs, NC. The gravity sewer will be a public system owned and operated by the Town of Holly Springs. Phase 1 of the project will consist of approximately 30 residential units. The total wastewater flow generated by Phase 1 of the project is 7,650 GPD. Sincerely, MCADAMS Curt Blazier, PE Assistant Project Manager, Residential CB/md creating experiences through experience 2905 Meridian Parkway, Durham, N[ 27713 1919- 361. 5000 9 M('Al)AMS July 12, 2019 NCDENR — DWR Raleigh Regional Office 1628 Mail Service Center Raleigh, North Carolina 27699-1628 I 3 r,� ic�i • I-A5 f-TRACK Ak_RIAL SEWER Ll T71»!% RE: Steeplechase Phase 1 Sanitary Sewer System Extension Application — Aerial Sewers Holly Springs, North Carolina PLT-18000 NC Dept of Environmental Quality SEP - 5 2019 Raleigh Regional Office The accompanied Fast -Track Application (FTA 04-16) includes 2,451 lineal feet of 8" PVC and 788 lineal feet of 8" DIP associated with the proposed Steeplechase Phase 1 development located at 5836 Cass Holt Road in Holly Springs, NC. Two (2) aerial crossings are proposed in the off -site sanitary sewer outfall to the west of the development. The first aerial crossing is approximately 126 lineal feet of 8" RJ DIP from proposed SSMH-103 at Sta. 11+09 to proposed SSMH-104 at Sta. 12+35. The span from bank to bank of the existing stream will be approximately 80 lineal feet and will include two (2) piers. This aerial crossing is shown on Sheet CS.07 of the Construction Plan set. The second aerial crossing is approximately 131 lineal feet of 8" RJ DIP from proposed SSMH-107 at Sta. 20+55 to proposed SSMH-108 at Sta. 21+86. The span from bank to bank of the existing stream will be approximately 68 lineal feet and will include two (2) piers. This aerial crossing is shown on Sheet C5.08 of the Construction Plan set. Sincerely, MCADAMS Curt Blazier, PE Assistant Project Manager, Residential CB/md creating experiences through experience 2905 Meridian Parkway. Durham, NC 27723 / 919. 361. SOW J-1 OU T H E TO W N OFINT i August 19, 2019 Director, Division of Water Resources Raleigh Regional Office Water Quality Operation Section 1628 Mail Service Center Raleigh, NC 27699-1628 Re: Application for Sewer Extension Permit Project: Steeplechase, Phase I Dear Sir or Madam: 9pri)VS NC Dept of Environmental Quality SEP - 5 2019 Raleigh Regional Office Please find enclosed the following items in application for a sewer extension permit to the Town of Holly Springs existing sewer distribution system: 0 One original and one copy cover letter including a project narrative o A check in the amount of $480.00 0 One original and one copy of the State of North Carolina Fast Track Sewer System Extension Application (FTA 04-16) 0 Two copies of FTSE 04-16 Flow Tracking/Acceptance Form 0 Two color copies of a 8.5-inch by I 1-inch portion of a 7.5 minute USGS Topographic Map showing project area 0 Two copies of a street level map showing all relevant project areas 0 One copy of the locally -required Design and Application Certification Feel free to contact me at 919-557-3938 should you have any questions or need additional information in order to process this application. Sin erely, endra D. P ish, P. ., CFM Director of En ineering KP/se cc: Project Consultant Engineer, Curtis Blazier, John R. McAdams Company Administrative Manager (for addition to sewer permit log) Rodney Campbell, Development Administrator Project file/Correspondence 441755 3002 04.17.201 S Engineering Deparhnent P.O. Box 8 - 128 S. Main Street - Holly Springs, NC 27540 - www.hollyspringsnc.us DO NOT SUBMIT SEWER EXTENSION APPLICATIONS UNTIL CONSTRUCTION DRAWINGS HAVE BEEN APPROVED BY STAFF! E Sewer Design and Application Certification y Note: This farm must be submitted with the Fast -Tract Application for -Gravity Sewers, Pump c Stations, and Force Mains for extension to the Town of Holly Springs Sewer System •� Project: Steeplechase - Phase 1 Design Engineer: Curtis BlaZler Address: 2905 Meridian Parkway, Durham, NC 27713 z Phone Number: 919-361-5000 Email: bfazier@mcadamsco.com Date Complete Application Package Received by Town: ILM.-)to 19 Date Approved: k G Oliq (by RLC}�JV (by KDP) As design engineer for this project, I certify the following (please check (x) each applicable box): x❑ That the design of the project is in complete conformance with Town of Holly Springs Engineering Design and Construction Standards and NCDENR Sanitary Sewer Design Regulations; x❑ That each of the following items are completed and enclosed for submittal to the State for a sewer extension permit: 0 One original and one copy cover letter including a project narrative o A check in the amount of $480.00 to DENR o A check in the amount of $200.00 Town processing fee 0 One original and one copy of the State of North Carolina Fast Track Application for Gravity Sewers, Pump Stations, and Force Mains 0 Two copies of FTSE 08-13 Flow Tracking/Acceptance Form 0 Two color copies of a 8.5-inch by 11-inch portion of a 7.5 minute USGS Topographic Map showing project area 0 Two copies of a street level map showing all relevant project areas 0 One copy of the locally -required Pesigin and Application Certification Design Engineer's Signature In addition, once your construction drawings are approved and this application is complete, you will receive a copy of the Town's letter of transmittal to the State as your confirmation that the application is complete and has been forwarded to the State for permitting. PIease contact Sara Emig at (919) 557-3926 if you do not receive this confirmation or if you have any questions. Engineering Department - P.O. Box 8, Holly Springs, NC 27540 919-557-3938 - 919-552-9881 (fax) 2003 Sewcr Design Application CLnification a4 11.20t8