Loading...
HomeMy WebLinkAboutWQ0000193_Inspection_20190919DocuSign Envelope ID: CCBOE4CE-28F2-477E-8001-48D33F72293A ROY COOPED Covemar A ICHAEL S. REGAN Secretary LINDA CULPEPPER OZrNrtpr Kennith Dwain Bowling Village of Bald Head Island PO Box 3009 Bald Head Island, NC 28461-3009 NORTH CARODNA Environmental Quality September 30, 2019 SUBJECT: Compliance Inspection Report Bald Head Island WWTF Non -discharge Permit No. WQ0000193 Brunswick County Dear Permittee: The North Carolina Division of Water Resources conducted an inspection of the Bald Head Island WWTF on 9/19/2019. This inspection was conducted to verify that the facility is operating in compliance with the conditions and limitations specified in Non -discharge Permit No. WQ0000193. The findings and comments noted during this inspection are provided in the enclosed copy of the inspection report entitled "Compliance Inspection Report". There were no significant issues or findings noted during the inspection and therefore, a response to this inspection report is not required. If you should have any questions, please do not hesitate to contact Helen Perez with the Water Quality Regional Operations Section in the Wilmington Regional Office at 910-796-7215 or via email at helen.perez@ncdenr.gov. Sincerely, Do'T�n�SigneE-T,o-,',' d by: r. �cotiF1E73B6F3456_ for Morelia Sanchez -King, Regional Supervisor Water Quality Regional Operations Section Wilmington Regional Office Division of Water Resources, NCDEQ ATTACHMENTS Cc: David Suther — electronic copy Uploaded to Laserfiche North CaroLrsgDepartmentofEnvironmeatalQualk%- I DiuisionofWater Resources Wilmington Reg•3iLa- Dffioe l 127 C.ardirrei Drive Extensors l V`ilrar:ngton, North Car•o--rs 2-3405 "•• 910-796-7215 DocuSign Envelope ID: CCBOE4CE-28F2-477E-8001-48D33F72293A Compliance Inspection Report Permit: WQ0000193 Effective: 08/08/17 Expiration: 11/30/20 owner: Village of Bald Head Island SOC: Effective: Expiration: Facility: Bald Head Island WWTF County: Brunswick 256 Edward Teach Wynd Region: Wilmington Bald Head Island NC 284613069 Contact Person: Kennith Dwain Bowling Title: Phone: 910-457-7350 Directions to Facility: System Classifications: SI, WW3, Primary ORC: David Albert Suther Certification: 27326 Phone: 910-457-7352 Secondary ORC(s): On -Site Representative(s): On -site representative David A Suther 910-457-7352 Related Permits: WQ0000455 Lewis Farms and Liquid Waste Inc - Lewis Farms and Liquid Waste RLAP Inspection Date: 09/19/2019 Entry Time: 10:30AM Exit Time: 11:45AM DocuSigned by: Primary Inspector: Helen I Perez E,1D645B4A3969P411F_DocuSigned Phone: 910-796-7387 Secondary Inspector(s): by: Tom Tharrington - Tom- -N..cc, oti Phone Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: Other Non -Discharge Wastewater Facility Status: Compliant Not Compliant Question Areas: Treatment Flow Measurement -Effluent Treatment Flow Measurement -Influent Miscellaneous Questions Treatment Flow Measurement -Water Treatment Treatment Barscreen Use Records Treatment Filters Record Keeping Treatment Activated Sludge Treatment Sludge Storage/Treatment Treatment Disinfection Treatment Flow Measurement End Use -Reuse Standby Power (See attachment summary) Page 1 of 7 DocuSign Envelope ID: CCBOE4CE-28F2-477E-8001-48D33F72293A Permit: WQ0000193 Owner - Facility: Village of Bald Head Island Inspection Date: 09/19/2019 Inspection Type : Compliance Evaluation Reason for Visit: Routine Inspection Summary: A routine compliance inspection of the Bald Head Island WWTF was conducted on September 19, 2019. The purpose of the evaluation was to verify that the facility is operating in compliance with the conditions and limitations specified in Permit WQ0000193. Staff members David Suther and Nathan Lindsay were present during the inspection. This facility is permitted for 300,000 gpd of flow and averages 180,000-220,000 gpd of flow in the summer months and 75,000 gpd in the winter. Effluent disposal consists of conjunctive and non -conjunctive reclaim water utilization on the Bald Head Island Club facility and two high -rate infiltration ponds. The facility is well maintained, and operation and maintenance records are detailed and complete. A review of monitoring records since the last inspection show 2 NODs in 2017 for total nitrogen and ammonia effluent limit non-compliance and 2 NOVs in 2018 for fecal, TSS, ammonia and BOD effluent limit non-compliance. Groundwater monitoring since the last inspection shows some violations of TDS in a few of the monitoring wells. TDS is typical in groundwater in an island environment, and the Wilmington Regional Office will continue to monitor the wells. The facility is compliant with the non -discharge permit W00000193. Please review the comment sections of the inspection report for more details. Page 2 of 7 DocuSign Envelope ID: CCBOE4CE-28F2-477E-8001-48D33F72293A Permit: WQ0000193 Inspection Date: 09/19/2019 Owner - Facility: Village of Bald Head Island Inspection Type : Compliance Evaluation Reason for Visit: Routine Type Yes No NA NE Lagoon Spray, LR ❑ Activated Sludge Spray, HR ❑ Activated Sludge Drip, LR ❑ Single Family Spray, LR ❑ Activated Sludge Spray, LR ❑ Recycle/Reuse ❑ Single Family Drip ❑ Reuse (Quality) Infiltration System Treatment Yes No NA NE Are Treatment facilities consistent with those outlined in the current permit? 0 ❑ ❑ ❑ Do all treatment units appear to be operational? (if no, note below.) 0 ❑ ❑ ❑ Comment: No comment. Treatment Flow Measurement -Influent Yes No NA NE Is flowmeter calibrated annually? 0 ❑ ❑ ❑ Is flowmeter operating properly? ❑ ❑ ❑ Does flowmeter monitor continuously? 0 ❑ ❑ ❑ Does flowmeter record flow? 0 ❑ ❑ ❑ Does flowmeter appear to monitor accurately? 0 ❑ ❑ ❑ Comment: The flow meter was calibrated on 12/2/2018 by JS. Dismuke Co, Inc. Treatment Flow Measurement -Water Use Records Yes No NA NE Is water use metered? ❑ ❑ 0 ❑ Are the daily average values properly calculated? ❑ ❑ 0 ❑ Comment: Treatment Flow Measurement -Effluent Yes No NA NE Is flowmeter calibrated annually? ❑ ❑ 0 ❑ Is flowmeter operating properly? ❑ ❑ 0 ❑ Does flowmeter monitor continuously? ❑ ❑ 0 ❑ Does flowmeter record flow? ❑ ❑ 0 ❑ Does flowmeter appear to monitor accurately? ❑ ❑ 0 ❑ Comment: Standby Power Yes No NA NE Is automatically activated standby power available? 0 ❑ ❑ ❑ Page 3 of 7 DocuSign Envelope ID: CCBOE4CE-28F2-477E-8001-48D33F72293A Permit: WQ0000193 Owner - Facility: Village of Bald Head Island Inspection Date: 09/19/2019 Inspection Type : Compliance Evaluation Reason for Visit: Routine Is generator tested weekly by interrupting primary power source? ❑ ❑ ❑ Is generator operable? ❑ ❑ ❑ Does generator have adequate fuel? ❑ ❑ ❑ Comment: The generator is tested under load weekly and provides stand-by power to both the WWTF and the WTP. Power Pro Tech is contracted to maintain the generator. Treatment Barscreen Yes No NA NE Is it free of excessive debris? 0 ❑ ❑ ❑ Is disposal of screenings in compliance? 0 ❑ ❑ ❑ Are the bars spaced properly? ❑ 1:10 ❑ Is the unit in good condition? 0 ❑ ❑ ❑ Comment: Facility has a screw type mechanical bar sceen with a bag compactor. Treatment Activated Sludqe Yes No NA NE Is the aeration mechanism operable? 0 ❑ ❑ ❑ Is the aeration basin thoroughly mixed? 0 ❑ ❑ ❑ Is the aeration equipment easily accessed? ❑ ❑ ❑ Is Dissolved Oxygen adequate? ❑ ❑ ❑ Are Settleometer results acceptable? ❑ ❑ ❑ Is activated sludge an acceptable color? 0 ❑ ❑ ❑ Comment: Currently 2 out of the 3 SBRs were in operation. During the winter months, only 1 SBR is in operation. Treatment Filters Yes No NA NE Is the filter media present? ❑ ❑ 0 ❑ Is the filter media the correct size and type? ❑ ❑ 0 ❑ Is the air scour operational? ❑ ❑ 0 ❑ Is the scouring acceptable? ❑ ❑ 0 ❑ Is the clear well free of excessive solids? ❑ ❑ ❑ Is the mud well free of excessive solids and filter media? ❑ ❑ ❑ Does backwashing frequency appear adequate? 0 ❑ ❑ ❑ Comment: There are 2 cloth Aqua Disk Filters that are backwashed automatically. Treatment Sludge Storage/Treatment Yes No NA NE Is the aeration operational? ❑ ❑ ❑ Is the aeration pattern even? ❑ ❑ ❑ If required, are Sanitary "Ts" present in tankage? ❑ ❑ 0 ❑ Comment: Sludge is removed by Lewis Farms. Date and amount hauled is documented on a Sludge Hauling Log. Treatment Disinfection Yes No NA NE Page 4 of 7 DocuSign Envelope ID: CCBOE4CE-28F2-477E-8001-48D33F72293A Permit: WQ0000193 Owner - Facility: Village of Bald Head Island Inspection Date: 09/19/2019 Inspection Type : Compliance Evaluation Reason for Visit: Routine Is the system working? ❑ ❑ ❑ Do the fecal coliform results indicate proper disinfection? ❑ ❑ ❑ Is there adequate detention time (-30 minutes)? ❑ ❑ ❑ Is the system properly maintained? ❑ ❑ ❑ If gas, does the cylinder storage appear safe? ❑ ❑ ❑ Is the fan in the chlorine feed room and storage area operable? ❑ ❑ ❑ Is the chlorinator accessible? ❑ ❑ ❑ If tablets, are tablets present? ❑ ❑ ❑ Are the tablets the proper size and type? ❑ ❑ ❑ Is contact chamber free of sludge, solids, and growth? ❑ ❑ ❑ If UV, are extra UV bulbs available? ❑ ❑ ❑ If UV, is the UV intensity adequate? ❑ ❑ ❑ # Is it a dual feed system? ❑ ❑ ❑ Does the Stationary Source have more than 2500 Ibs of Chlorine (CAS No. 7782-50-5)? ❑ ❑ ❑ If yes, then is there a Risk Management Plan on site? ❑ ❑ ❑ If yes, then what is the EPA twelve digit ID Number? (1 000) If yes, then when was the RMP last updated? Comment: There are 2 UV banks in series and a secondary tablet chlorinator. Record Keeping Yes No NA NE Is a copy of current permit available? ❑ ❑ ❑ Are monitoring reports present: NDMR? ❑ ❑ ❑ NDAR? ❑ ❑ ❑ Are flow rates less than of permitted flow? ❑ ❑ ❑ Are flow rates less than of permitted flow? ❑ ❑ ❑ Are application rates adhered to? ❑ ❑ ❑ Is GW monitoring being conducted, if required (GW-59s submitted)? ❑ ❑ ❑ Are all samples analyzed for all required parameters? ❑ ❑ ❑ Are there any 2L GW quality violations? ❑ ❑ ❑ Is GW-59A certification form completed for facility? ❑ ❑ ❑ Is effluent sampled for same parameters as GW? ❑ ❑ ❑ Do effluent concentrations exceed GW standards? ❑ ❑ ❑ Are annual soil reports available? ❑ ❑ ❑ # Are PAN records required? ❑ ❑ ❑ # Did last soil report indicate a need for lime? ❑ ❑ ❑ If so, has it been applied? ❑ ❑ ❑ Are operational logs present? ❑ ❑ ❑ Page 5 of 7 DocuSign Envelope ID: CCBOE4CE-28F2-477E-8001-48D33F72293A Permit: WQ0000193 Owner - Facility: Village of Bald Head Island Inspection Date: 09/19/2019 Inspection Type : Compliance Evaluation Reason for Visit: Routine Are lab sheets available for review? ❑ ❑ ❑ Do lab sheets support data reported on NDMR? ❑ ❑ ❑ Do lab sheets support data reported on GW-59s? ❑ ❑ ❑ Are Operational and Maintenance records present? ❑ ❑ ❑ Were Operational and Maintenance records complete? ❑ ❑ ❑ Has permittee been free of public complaints in last 12 months? ❑ ❑ ❑ Is a copy of the SOC readily available? ❑ ❑ ❑ No treatment units bypassed since last inspection? ❑ ❑ ❑ Comment: ODerational and maintenance records were oraanized and comDlete. Dailv/monthlv trackin forms document SBR, blower and Aqua Disk operations. This information, along with information from various other daily lops is entered into a computer speadsheet for tracking. Field parameters are analyzed by staff, lab certification # 5301. Calibration sheets for pH and DO were complete. All other parameters are analyzed by Envirochem, lab certification #94. Discussed with staff the need to relinquish samples to Envirochem with a signature, date and time on COC before securing cooler for delivery. End Use -Reuse Yes No NA NE Is the acreage in the permit being utilized? ❑ ❑ ❑ Does the acreage specified in the permit correspond to the measured acreage at the site? ❑ ❑ ❑ Are all essential units provided in duplicate? ❑ ❑ ❑ Is an automatically activated standby power source available? ❑ ❑ ❑ Is the equalization capacity adequate? ❑ ❑ ❑ Is aerated flow equalization present? ❑ ❑ ❑ Has the turbidity meter been calibrated in the last 12 months? ❑ ❑ ❑ Does the turbidity meter have recording capabilities? ❑ ❑ ❑ Is all flow diverted at the appropriate times? ❑ ❑ ❑ Is all upset wastewater diverted from reuse storage unit? ❑ ❑ ❑ Is all upset wastewater treated, retreated, or disposed of acceptably? ❑ ❑ ❑ Is upset wastewater treated prior to discharge to irrigation storage? ❑ ❑ ❑ Is public access restricted from irrigation area during active site use? ❑ ❑ ❑ If golf course, is a sign posted in plain sight on the club house? ❑ ❑ ❑ Is the cover crop acceptable? ❑ ❑ ❑ Are buffers adequate? ❑ ❑ ❑ Is the site free of ponding/runoff? ❑ ❑ ❑ Is the acreage in the permit being utilized? ❑ ❑ ❑ Is the application equipment acceptable? ❑ ❑ ❑ Is the application area free of limiting slopes? ❑ ❑ ❑ How close is the closest water supply well? ❑ ❑ ❑ Are any supply wells within the CB? ❑ ❑ ❑ Page 6 of 7 DocuSign Envelope ID: CCBOE4CE-28F2-477E-8001-48D33F72293A Permit: WQ0000193 Owner - Facility: Village of Bald Head Island Inspection Date: 09/19/2019 Inspection Type : Compliance Evaluation Reason for Visit: Routine Are any supply wells within 250' of the CB? ❑ ❑ ❑ Is municipal water available in the area? ❑ ❑ ❑ Are GW monitoring wells required? ❑ ❑ ❑ Are GW monitoring wells located properly w/ respect to RIB and CB? ❑ ❑ ❑ Are GW monitoring wells properly constructed, including screened interval? ❑ ❑ ❑ Comment: The turbidity meter was calibrated on 06/18/2018 by JS Dismuke Co, Inc. The facility does not have a 5-day upset pond. Instead, effluent is routed to the high -rate infiltration basins when fecal or turbidity limits are out of reuse compliance. All of the conjunctive reclaimed water irrigation is managed by the staff of the Bald Head Island Club. The remaining disposal is mangaed by the WWTF. None of the disposal sites were evaluated during this inspection. Page 7 of 7