HomeMy WebLinkAboutSW3190506_Form_(Supp.EZ)_20191015SUPPLEMENT-EZ COVER PAGE
FORMS LOADED
PROJECT INFORMATION
1 Project Name - -
4 ISUirface Water Area ac
5 Is this project High or Low Denslt 7
6 Does this project use an off -site SCM7
COMPLIANCE WITH 02H .1003(4)
7 Width of vegetated setbacks provided feel
8 Will the vegetated setback remain vegetate(
9 Is BUA other that as listed in .1 0034 c-d o
10 Is streambank stabilization DroDosed on this
Sealand Office
24.3
No
NUMBER AND TYPE OF SCMs:
11Infiltration System 0
12
Biorelention Coll
0
13
Wet Pond
0
14
Stormwater Wotland
0
15
Permeable Pavement
0
16
Sand Filter
1
17
Rainwater Harvesting RWH
0
18
Green Roof
0
19
Level Spreader -Filter Strip LS-IFS)0
20
Disconnected Impervious Surface (DIS)
0
21
Treatment Swale
0
22
Dry Pond
0
23
Storm Filter
0
24
Silva Cell
0
25
Bayrilter
0
26
Filterra
0
FORMS LOADED
DESIGNER CERTIFICATION
27 Name and Title: Frank Cantrell
28
Organization:
Cardno
29
Street address:
_
9800 Southern Pine Blvd. Suite I
30
City, State, Zip:
Charlotte, NC 28273
31
Phone numbers :
980-422-0936
32
Email:
frank.cantrell@cardno.com
Certification Statement:
I certify, under penalty of law that this Supplement-EZ form and all Supporting information were prepared under my direction or
supervision; that the information provided in the form is, to the best of my knowledge and belief, true, accurate, and complete; and
that the engineering plans, specifications, operation and maintenance agreements and other supporting information are consistent
with the information provided here.
uesrgner
,yi�tirrrrrrrrrr.
SEA
0398.11
N VON
•,'y/r �, rCA�t%"�
Seal
Signature of Designer
Date
R12i 17,019
DRAINAGE AREAS
1
Is this a high density project?
Yes
2
If so, number of drainage areaslSCMs
1
3
Is alllpart of this project subject to previous rule
versions?
No
FORMSLOADED
DRAINAGE AREA INFORMATION Entire Site
4 Type of SCM Sand Filter
1
Sand Filter
5
1 Total BUA in project (sq ft
_
102095 sf
102095 sf
6
New BUA on subdivided lots (subject to permitting)
(sq ft
7permitting)
New BUA outside of subdivided lots (subject to
s
8
Offsite - total area (sq ft
9
Offsite BUA s ft
10
Breakdown of new BUA outside subdivided lots:
- Parking (sq ft
43926 sf
43926 sf
- Sidewalk sq ft
6870 sf
6870 sf
- Roofs ft
20250 sf
20250 sf
- Roadway s ft
28049 sf
28049 sf
- Future (sq ft
3000 sf
3000 sf
- Other, please specify in the comment box
below (sq ft
11
New infiltrating permeable pavement on
subdivided lots (sq ft
12
New infiltrating permeable pavement outside of
subdivided lots (sq ft
13permitting)
Exisitng BUA that will remain (not subject to
s ft
14
Existing BUA that is already ermitted s ft
15
Existing BUA that will be removed (sq ft
16
Percent SUA
40%
40%
17
Design storm inches
1 in
1 in
18
Design volume of SCM cu ft
8728 cf
8728 cf
19
Calculation method for design volume
ADDITIONAL INFORMATION
20
Please use this space to provide any additional information about the
drainage area(s):
DRAINAGE AREA INFORMATION Entire Site 1
4 Type of SCM NIA___ _
5 Total BUA from project (sq ft)
6
1995 rules
_
SL 2006-246
2008 rules
_
2017 rules
7
New BUA on subdivided lots (subject to
permitting) (sq ft)
1995 rules
SL 2006-246
2008 rules _
2017 rules
8
New BUA outside of subdivided lots (subject to
permitting) (SO
1995 rules-
��
SL 2006-246
2008 rules
2017 rules
9
Offslte - total area (sq ft)
1995 rules
SL 2006-246
2008 rules
2017 rules
10
Offstte BUA (sq ft)
SAND FILTER
1 Drainage area number 1
2 Design volume of SCM (cu ft) 8728 sf
GENERAL MDC FROM 02H .1050 _
3 11stheSCM sized to treat the SW from all surfaces at build -out? Yes
4 1 Is the SCM located away from contaminated soils? Yes
5What are the side slopes of the SCM (H:V)? 3:1
6
side slopes?
No
7
Are the inlets, outlets, and receiving stream protected from erosion (10-
year storm)?
Yes
8
Is there an overflow or bypass for inflow volume in excess of the design
volume?
Yes
9
What is the method for dawatering the SCM for maintenance?
Pump (preferred)
10
If applicable, will the SCM be cleaned out after construction?
Yes
11
Does the maintenance access comply with General MDC (8)?
Yes
12
Does the drainage easement comply with General MDC (9)?
Yes
13
If the SCM is on a single family lot, does (will?) the plat comply with
General MDC (10)?
14
Is there an O&M Agreement that complies with General MDC (11)?
Yes
15
Is there an O&M Plan that complies with General MDC (12)?
Yes
16
Does the SCM follow the device specific MDC?
Yes
17 vvas the SUM designed by an NG licenseo protessional7 Yes
SAND FILTER MDC FROM 02H .1056
18 �SHWT elevation (fmsl) I Less Than 678 .1
or
this sand
Chamhar
23
Volume that can be retained in the sediment chamber (cubic feet)
19549 cf
24
Will there be a permanent pool in the sediment chamber?
No
25
Bottom of the sediment chamber (fmsl)
684.00
26
Area of the sediment chamber (square feet)
4825 sf
27
Physical depth of the sediment chamber (inches)
24 In
28
Ponding depth in the sediment chamber, above any permanent pool
(inches)
7 in
29
1 Elevation of top of weir between chambers (fmsl)
686
ISond Chamher
30
Volume that can be retained in the sand chamber (cubic feet)
19549 cf
31
Bottom of the sand chamber (fmsl)
683.50
32
Area of the sand chamber (square feet)
5114 sf
33
Physical depth of the sand chamber (inches)
24 in
34
Ponding depth in the sand chamber, above any permanent pool
(inches)
7 in
35
Elevation of the bypass device (fmsl)
687.5
36
Type of bypass device
Overflow Wier
37
Mechanism for distributing flow over the sand surface
Rip -Rap Berm
38
Sand specification for sand chamber
ASTM 33
39
Depth above underdrain pipe (inches)
36 in
40
Will the media be maintained to drain at least two inches per hour at the
sand surface?
Yes
41
Is at least one clean -out pipe provided at the low point of each
underdrain line?
Yes
42
Will clean -out pipes be capped?
Sand Filter 4 9:14 AM 9/27/2019