Loading...
HomeMy WebLinkAboutWQ0041240_Application (FTSE)_20191008i Vys �� �J2 lC (' 1 0� ��State of North Carolina Department of Environmental Quality INWRDivision of Water Resources —momor 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Dkblon of W#Eer Resources FTA 04-16 & SUPPORTING DOCUMENTATION Application Number: 00-t l -;Lb (to be completed by Dwtz) All items must be completed or the application will be returned I. APPLICANT INFORMATION: 1. Applicant's name: Town of Pilot Mountain (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Privately -Owned Public Utility ❑ Federal ❑ State/County ® Municipal ❑ Other 3. Signature authority's name: Michael Boaz per 15A NCAC 02T .0106(b) Title: Town Manaeer 4. Applicant's mailing address: 124 W. Main Street City: Pilot Mountain State: NC Zip: 27041 5. Applicant's contact information: Phone number: (336) 444-3000 Email Address: mboaz .pilotmountainnc.org II. PROJECT INFORMATION: 1. Project name: Sunset Sewer Subbasin Rehabilitation Project 2. Application/Project status: ® Proposed (New Permit) ❑ Existing Permit/Project If a modification, provide the existing permit number: WQ00 and issued date: If new construction but part of a master plan, provide the existing permit number: W000 3. County where project is located: Surry 4. Approximate Coordinates (Decimal Degrees): Latitude: 30.23.24' Longitude:-80.28.51` 5. Parcel ID (if applicable): (or Parcel ID to closest downstream sewer) IawV-135-111aF.11►Y1lZI-Te]W I:11 133 1, Professional Engineer: John F. Akers License Number: 024645 Firm: WithersRavenel Mailing address: 424 Gallimore Dairy Road, Suite C City: Greensboro State: NC Zip: 27409- Phone number: (336) 605-3009 Email Address: jakers@withersravenel.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: Town of Pilot Mountain Permit Number: NCO026646 Owner Name: Town of Pilot Mountain V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1. Permit Number(s): WQ Downstream (Receiving) Sewer Size: 8 inch System Wide Collection System Permit Number(s) (if applicable): WQCS00112 Owner Name(s): Town of Pilot Mountain FORM: FTA 04-16 Page I of 5 State of North Carolina Department of Environmental Quality DWR000,Division of Water Resources 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Division of Water Resources FTA 04-16 & SUPPORTING DOCUMENTATION Application Number: I V (to be completed by DWR) All items must be completed or the application will be returned I. APPLICANT INFORMATION: I. Applicant's name: Town of Pilot Mountain (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Privately -Owned Public Utility ❑ Federal ❑ State/County ® Municipal ❑ Other 3. Signature authority's name: Michael Boaz per 15A NCAC 02T .0106(b) Title: Town Manager - NC Department of 4. Applicant's mailing address: 124 W. Main Street Environmental Quality Received City: Pilot Mountain State: NC Zip: 27041- - OCT O 8 2019 5. Applicant's contact information: Phone number: (3) 444-3000 Email Address: mboazOVilotmountainnc org i Winston-Salem Regional Office I1. PROJECT INFORMATION: 1. Project name: Sunset Sewer Subbasin Rehabilitation Project 2. Application/Project status: ® Proposed (New Permit) ❑ Existing Permit/Project If a modification, provide the existing permit number: W000 and issued date: If new construction but part of a master plan, provide the existing permit number: W000_ 3. County where project is located: Sorry 4. Approximate Coordinates (Decimal Degrees): Latitude: 30.23.24' Longitude:-80.28.51 ° 5. Parcel ID (if applicable): (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional Engineer: John F. Akers License Number: 024645 Firm: WithersRavenel Mailing address: 424 Gallimore Dairy Road, Suite C City: Greensboro State: NC Zip: 27409-_ Phone number: (336) 605-3009 Email Address: iakers(a withersravenel.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: _ Permit Number: Owner Name: V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1. Permit Number(s): WQ Downstream (Receiving) Sewer Size: 8 inch System Wide Collection System Permit Number(s) (if applicable): WQCS00112 Owner Name(s): Town of Pilot Mountain FORM: FTA 04-16 Page I of 5 THE COMPLETED APPLICATION PACKAGE INCLDING ALL SUPPORTING INFORMATION AND MATERIALS, SHOULD BE SENT TO THE APPROPRIATE REGIONAL OFFICE: REGIONAL OFFICE ADDRESS COUNTIES SERVED Asheville Reaional Office 2090 US Highway 70 Avery, Buncombe, Burke, Caldwell, Cherokee, Water Quality Section Swannanoa, North Carolina 28778 Clay, Graham, Haywood, Henderson, Jackson, (828) 296-4500 Macon, Madison, McDowell, Mitchell, Polk, (828) 299-7043 Fax Rutherford, Swain, Transylvania, Yancey Fayetteville Regional Office 225 Green Street Suite 714 Anson, Bladen, Cumberland, Harnett, Hoke, Water Quality Section Fayetteville, North Carolina 28301-5094 Montgomery, Moore, Robeson, Richmond, (910) 433-3300 Sampson, Scotland (910)486-0707 Fax Mooresville Regional Office 610 E. Center Avenue Alexander, Cabarrus, Catawba, Cleveland, Water Quality Section Mooresville, North Carolina 28115 Gaston, Iredell, Lincoln, Mecklenburg, Rowan, (704) 663-1699 Stanly, Union (704)663-6040 Fax Raleigh Regional Office 1628 Mail Service Center Chatham, Durham, Edgecombe, Franklin, Water Quality Section Raleigh, North Carolina 27699-1628 Granville, Halifax, Johnston, Lee, Nash, (919) 791-4200 Northampton, Orange, Person, Vance, Wake, (919) 788-7159 Fax Warren, Wilson Washington Regional Office 943 Washington Square Mall Beaufort, Bertie, Camden, Chowan, Craven, Water Quality Section Washington, North Carolina 27889 Currituck, Dare, Gates, Greene, Hertford, Hyde, (252) 946-6481 Jones, Lenoir, Martin, Pamlico, Pasquotank, (252) 975-3716 Fax Perquimans, Pitt, Tyrrell, Washington, Wayne Wilmington Regional Office 127 Cardinal Drive Extension Brunswick, Carteret, Columbus, Duplin, New Water Qualitv Section Wilmington, North Carolina 28405 Hanover, Onslow, Fender (910) 796-7215 (910)350-2004 Fax Winston-Salem Regional Office 450 W. Hanes Mill Road Suite 300 Alamance, Alleghany, Ashe, Caswell, Davidson, Davie, Forsyth, Guilford, Rockingham, Randolph, Water Quality Section Winston-Salem, North Carolina 27105 Stokes, Surry, Watauga, Wilkes, Yadkin (336)776-9800 INSTRUCTIONS FOR FORM: FTA 04-16 & SUPPORTING DOCUMENTATION Page 3 of 3 Vl. GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes [:]No ®N/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEV) been attached? ❑ Yes ❑No ®N/A 3. If the Applicant is a Home/Property Owners' Association, has an Operational Agreement (FORM: HOA) been attached? ❑ Yes ❑No ®N/A 4. Origin of wastewater: (check all that apply): ® Residential Owned ❑ Retail (stores, centers, malls) ❑ Car Wash ❑ Residential Leased ❑ Retail with food preparation/service ❑ Hotel and/or Motels ® School / preschool / day care ❑ Medical / dental / veterinary facilities ❑ Swimming Pool /Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash ❑ Businesses / offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment) 5. Nature of wastewater : 100 % Domestic/Commercial % Commercial % Industrial (See 15A NCAC 02T .0103(20)) "Is there a Pretreatment Program in effect? ❑ Yes ❑ No 6. Hasa flow reduction been approved under 15A NCAC 02T .0114(f)? ❑ Yes ❑ No ➢ If yes, provide a copy of flow reduction approval letter 7. Summarize wastewater generated by project: Establishment Type (see 02T.0114(I)) Daily Design Flow e,n No. of Units Flow High School 9,420 gal/daqy 1 9,420 GPD Residential 360 gal/minute/dwelling 68 24,480 GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD Total 33,900 GPD a See 15A NCAC 02T .0114(b), (d), (e)(1) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.01141 shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 0.034 GPD (per 15A NCAC 02T .0l 14) ➢ Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number: ❑ Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain): FORM: FTA 04-16 Page 2 of 5 VIL GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers): 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material ➢ Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria ➢ Section III contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Pump Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT I. Pump station number or name: Sunset Lift Station 2. Approximate Coordinates (Decimal Degrees): Latitude: 30.23.24' Longitude:-80.28.51 ° 3. Design flow of the pump station: 0.144 millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): 100 gallons per minute at 94 feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material 4 1,970 PVC 6. Power reliability in accordance with 15A NCAC 02T .0305(h)(l): ® Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(B). ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): ➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of 5 IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T.0305(f)): 1. Does the project comply with all separations found in 15A NCAC 02T.0305(f) & W tZ Yes ❑ No ➢ 15A NCAC 02T.0305(f) contains minimum separations that shall be provided for sewer systems: Setback Parameter* Separation Required Storm sewers and other utilities not listed below vertical 24 inches Water mains vertical -water over sewer including in benched trenches 18 inches Water mains horizontal 10 feet Reclaimed water lines vertical - reclaimed over sewer 18 inches Reclaimed water lines horizontal - reclaimed over sewer 2 feet **Any private or public water supply source, including any wells, WS-1 waters of Class I or Class II impounded reservoirs used as a source of drinking water 100 feet **Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal high water or tide elevation and wetlands see item IX.2 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet Any basement 10 feet Top sloe of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade vertical 36 inches ➢ 15A NCAC 02T.0305(g) contains alternatives where separations in 02T.0305(f) cannot be achieved. ➢ **Stream classifications cart be identified using the Division's NC Surface Water Classifications webpage ➢ If noncompliance with 02T.0305(f) or (g), see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ® Yes ❑ No ❑ N/A ➢ See the Division's draft separation requirements for situations where separation cannot be meet ➢ No variance is required if the alternative design criteria specified is utilized in design and construction ➢ As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per 15A NCAC'02B .0200? ®Yes ❑ No ❑ N/A ➢ This would include Trout Buffered Streams per 15A NCAC 213.0202 4. Does the project require coverage/authorization under a 404 Nationwide or ❑ Yes ® No individual permits or 401 Water Quality Certifications? ➢ Information can be obtained from the 401 & Buffer Permitting Branch 5. Does project comply with 15A NCAC 02T.0105(c)(6) (additional permits/certifications)? ® Yes ❑ No Per 15A NCAC 02T.0105(c)(6), directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per 15A NCAC 02T.0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. ❑ Yes ® No ❑ N/A ➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 X. CERTIFICATIONS: I. Does the submitted system comply with 15A NCAC 02T, the Minimum Design Criteria for the Permitting of Pump Stations and Force Mains (latest version), and the Gravity Sewer Minimum Design Criteria (latest version) as applicable? ® Yes ❑ No If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review. Approval of the reauest is required Prior to submittal of the Fast Track Application and supporting documents. 2. Professional Engineer's Certification: tid F• 4kers attest that this application for (Professional Engineer's name from Application Item III.1.) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. North Carolina Professional Engineer's seal, signature, and date:' 3. Applicant's Certification per 15A NCAC 02T .0106(b): that this application for (Signature Authority's name & title from Ap)51ication Item I.3.) has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: Date: FORM: FTA 04- l6 Page 5 of 5 State of North Carolina DWR Department of Environmental Quality Division of Water Resources Division of water Resources Flow Tracking/Acceptance for Sewer Extension Applications (FTSE 04-16) Entity Requesting Allocation: Town of Pilot Mountain Project Name for which flow is being requested: Sunset Sewer Subbasin Rehabilitation More than one FTSE may be required fora single project if the owner of the WWTP is not responsible for all pomp stations along the route of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Town of Pilot Mountain WWTP li. WWTP Facility Permit #: NC0026646 All flows are in MGD c. WWTP facility's permitted flow 0.5000 d. Estimated obligated flow not yet tributary to the WWTP e. WWTP facility's actual avg. flow 0.1687 f. Total flow for this specific request g. Total actual and obligated flows to the facility It. Percent of permitted flow used 0.034 33% g05A e II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)=(B+C) (E)=(A-D) Design Obligated, Pump Average Daily Approx. Not Yet Total Current Station Firm Flow** Current Avg. Tributary Flow Plus (Name or Capacity, * (Firm / pi), Daily Flow, Daily Flow, Obligated Available Number) MGD MGD MGD MGD Flow Capacity*** * The Firm Capacity of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Downstream Facility Name (Sewer): Downstream Permit Number: Page 1 of 6 FTSE 04-16 III. Certification Statement: I Td N s mcc hu e 1 certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form indicates acceptance of this wastewater flow. Official Signature Date Page 2 of 6 FTSE 04-16 10 WithersRavenel. Our Peopte. Your Success. 424 Gattimore Dairy Road, Suite C Greensboro, North Carolina 27409 t: 336.605.3009 1 f: 919.467.6008 TO: Division of Water Quality 450 West Hanes Mill Road, Suite 300 Winston Salem, NC 27105 Letter of Transmittal • 10.04.2019 • • 06170524.00 • Fast Track Sewer System Permitting WEARESENDINGYOU ❑x Attached ❑ Under Separate Cover via THE FOLLOWING ITEMS ❑Shop Drawings ❑ Copy of Letter ❑ Prints ❑ Plans ❑ Samples ❑ Specifications ❑ Change Order ❑ Diskette ❑O Other Permit Application COPIESDATE 2 09.16.2019 NO. 1 DESCRIPTION Fast Track Permit Application & Flow Tracking Form 1 10.02.2019 2 Review Fee (Town of Pilot Mt. Check # 21332, $480.00) NC Department of ElIvIlumnental {uu ity Received W;Psten Salem Regional THESE ARE TRANSMITTED as checked below: ❑x For approval ❑ Approved as submitted ❑ For your use ❑ Approved as noted ❑ As requested, ❑ Returned for corrections ❑ For review and comment ❑ Other ❑ FOR BIDS DUE ❑ Resubmit ❑ Submit ❑ Return ❑ PRINTS RETURNED AFTER LOAN TO US copies for approval copies for distribution corrected prints REMARKS: The attached application is for permitting of a replacement lift station NC DEQ/Division of Water Infrastructure has requested that it be permitted, since it has not been individually permitted in the past. COPY TO: Town of Pilot Mountain SIGNED: John F. Akers PE Senior Project Manager If enclosures are not as noted, kindly notify us at once. Henderson, Justin L From: Akers, John <jakers@withersravenel.com> Sent: Monday, October 14, 2019 12:47 PM To: Henderson, Justin L Cc: Dolan, Casey; Rehak, Elisa; Michael Boaz Subject: [External] RE: Sunset Sewer Subbasin Rehabilitation Project Attachments: 2019.07.28 REVISED - Sewage Pump Station Design-Flow_2019_1014.pdf Justin: Attached is our full estimate of flow. We used the 15 gpd per student based on a school with cafeteria, gym and showers. I'll verify the obligated flow number with the town, but they did not indicate that they currently had any obligated flow to the plant. Thanks, John From: Henderson, Justin L <justin.hehderson@ncdenr.gov> Sent: Monday, October 14, 2019 12:02 PM To: Akers, John <jakers@withersravenel.com> Subject: Sunset Sewer Subbasin Rehabilitation Project John, I am reviewing a fast track application package for the subject project and have the following additional information requests: 1) How many students are being requested at the High School? 2) Does the school have a cafeteria? Gym & Showers? 3) The included FTSE indicated that the WWTP does not currently have any obligated but not yet tributary flow. Can you verify that this is accurate? The application will be placed on hold until the above information is received by this office. Please contact me with any questions you may have. Thanks. Justin Henderson Environmental Specialist II Winston Salem Regional Office Division of Water Resources (336)776-9701 iustin.henderson@ncdenr.gov Subscribe to Collection System & Sewer Permitting Updates Henderson, Justin L From: Akers, John <jakers@withersravenel.com> Sent: Tuesday, October 15, 2019 10:55 AM To: Henderson, Justin L Subject: [External] RE: Sunset Sewer subbasin rehab Attachments: Lift Station Permit Application-Page_1.pdf Justin: Attached is the revised page 1. The town confirmed that they have no obligated flow. Let me know if you need anything else. Thanks, John From: Henderson, Justin L <justin.henderson@ncdenr.gov> Sent: Monday, October 14, 2019 12:24 PM To: Akers, John <jakers@withersravenel.com> Subject: Sunset Sewer subbasin rehab John, One more additional information item to request for the subject project: 1) Submit a revised p. 1 of 5 of FTA with a completed Section IV. that provides the WWTP facility name, owner, and permit number. Thanks. Justin Henderson Environmental Specialist II Winston Salem Regional Office Division of Water Resources (336) 776-9701 iustin.henderson@ncdenr.gov Subscribe to Collection System & Sewer Permitting Updates TOWN OF PILOT MOUNTAIN Date Inv No./Desc 10/02/2019 PILOT MTN REVIEW FEE/LIPT STATION P.O. No. Amount $480.00 NC Donartment. of Environmental Quality Recelv2d OCT 0 8 2019 Winston-Salem Regional Office Check: 21332 10/02/2019 Total Amt: $480.00