Loading...
HomeMy WebLinkAbout20191119 Ver 1_More Info Received_20191014Strickland, Bev From: Williams, Kim <kwilliams@lmgroup.net> Sent: Friday, September 20, 2019 2:14 PM To: Capito, Rachel A CIV USARMY CESAW (US); Mairs, Robb L Subject: [External] Re: Aaronfield at Old Folkstone Attachments: Aaronfield Revised Maps 9-20-19.pdf External email. Do not click links or open attachments unless you verify. Send all suspicious email as an attachment to report.spam@nc.gov Hi Rachel and Robb I submitted a NWP application for the Aaronfield at Old Folkstone project in Onslow County a few weeks ago. The applicant recently revised their site plan to move the building shown at the front of the site to the back. They will need to put a stormwater pond back here as well and plan to place another outfall pipe in the stream. Attached are the revised site plan drawings. Wetland and open water impacts remain the same (0.003 ac and 0.01 ac respectively). Stream impacts have increased to 42 LF. Let me know if you have any questions or need additional info. Thanks! Kim Kim Williams I Environmental Scientist Land Management Group I Environmental Consultants Direct: 910-452-0001 x 1908 1 Cell: 910.471.5035 1 Fax: 910.452.0060 3805 Wrightsville Ave., Suite 15 1 Wilmington, NC 28403 Email: kwilliams@lmgroup.net I website: www.lmgroup.net On Thu, Sep 19, 2019 at 4:49 PM Williams, Kim <kwilliams@lmgroup.net> wrote: Hi Rachel I forwarded your comment to the engineer. He said they initially planned to use retaining walls here, but recently determined that it would be better to move building 2 to the back of the site. He is working on a revised plan right now and should have something to me shortly. I'll forward it as soon as I get it. Thanks! Kim Kim Williams I Environmental Scientist Land Management Group I Environmental Consultants Direct: 910-452-0001 x 1908 1 Cell: 910.471.5035 1 Fax: 910.452.0060 3805 Wrightsville Ave., Suite 15 1 Wilmington, NC 28403 Email: kwilliams@lmgroup.net I website: www.lmgroup.net On Thu, Sep 19, 2019 at 3:47 PM Capito, Rachel A CIV USARMY CESAW (US)<Rachel.A.Capito@usace.army.mil> wrote: Hey Kim, I'm reviewing this application and had a question about the wetland area near the parking lots of Building 2 and the Clubhouse. Will retaining walls be used in this location to prevent additional impacts to the wetland feature? Thanks, Rachel Rachel Capito Regulatory Specialist U.S. Army Corps of Engineers Wilmington District Office: 910.251.4487 Cell: 910.899.6051 SEE SHEET 5 GRAPHIC SCALE: 1" = 100, EX GRAD 404 WET 12 LF 16 LF WITH NO IMPACTS IMPACTS (WI)i (EXISTING CULVERT TO BE REMOVED) 0.5' 15, 111 14 5.0' 0, -1 RIP RAP APRON SIDEWALK CONCRETE HEADWALL 0 W/ HANDRAILS 24 LF IMPACTS (01) 25' BACK OF CURB -BACK OF CURB 0 6" DIP WATER INV 17.8 EL 26.0 37 LF 30" RCP SECTION A -A NTS ROADWAY: 26.0 0 8" DIP SEWER INV 17.9 t= 5.5' PLAZA CONCRETE HEADWALL EX 404 WET GRAD UPPER INV 20.2 1 Open Water Impact #1: 0.01 AC Culvert/Rip Rap Apron S C SMHCkAW 2 Wetland Impact #1: 0.003 ac (118 SF) Rip Rap Apron ru 8 . 0 o"/ A VAIE SEWER A 10 6.5 5. ? tOpZ \j ro .5O EX GRADE/ EX GRADE RCP 404 WETLAND 30"INV I 30 15' 0 30' 60' 20.1 O GRAPHIC 1 30' SCALE: TOE OF WALL: 19.5 8" DIP SEWER INV 17.9 ------------------------------------ — --------------------------------------------- 6" DIP WATER INV 17.8 -SECTION B -B NTS SECTION A -A NTS 0 �- 0 18 LF (MAX) IMPACT LENGTH a W � J W o� �a EX TOP OF BANK_ 24:0 +/- ----------------------- o� 30' 15' 0 30' 60' 3 18" RCP �1 INV 20.0 �� � GRAPHIC SCALE: 1 = 30 ...r r•.n r ..n • n r n w r v. e r n r r SECTION B -B NTS Z � 12 FT STREAM WIDTH g r J o r W 5 LF (AVERAGE) a 5; IMPACT WIDTH v a J EX GRADE EX GRADE �a 0 RIP RAP APRON 18" RCP 0000DQ OO INV 20.0 SECTION A -A NTS 0 �- 0 18 LF (MAX) IMPACT LENGTH a W � J W o� �a EX TOP OF BANK_ 24:0 +/- ----------------------- o� 30' 15' 0 30' 60' 3 18" RCP �1 INV 20.0 �� � GRAPHIC SCALE: 1 = 30 ...r r•.n r ..n • n r n w r v. e r n r r SECTION B -B NTS 18 FT STREAM WIDTH z r 5 LF (AVERAGE) g 5 IMPACT WIDTH rJ EX GRADE �a /0 EX GRADE RIP RAP APRON I 24" RCP nnnnn�nI INV 20.0 SECTION A -A NTS or o 13-Eor waEef UULT811 z_ z� 12 LF (MAX) IMPACT LENGTH a W � J W oa 0a EX TOP OF BANK: 21:0 +/- ._._._______ o� 30' 15' 0 30' 60' 3 24" RCP �1 INV 20.0 �� � GRAPHIC SCALE: 1 = 30 ...r r•.n r ..n • n r n n r v. e r n r r SECTION B -B NTS H 12 FT STREAM WIDTH g w o r 8 LF (AVERAGE) a 5; IMPACT WIDTH J EX GRADE EX GRADE o I I � ' RIP RAP APRON INV 20.0 18" RCP 00000� OO SE = CZ�/"'% SECTION A—A`EN ro S2o.o.oa�':�`••..� .. NTS �V Stream Impact #S3: 12 LF o Stormwater Outfall 12 LF (MAX) IMPACT LENGTH a W � J W oa EX TOP OF BANK_ 22:0 +/------------------------ o� 30' 15' 0 30' 60' 3 18" RCP �1 INV 20.0 �� � GRAPHIC SCALE: 1 = 30 ...r r•.n r ..n • n r n� r v. e r n r r SECTION B—B NTS