HomeMy WebLinkAboutNC0025071_NOD-2019-PC-0223_20191011 October 11, 2019 Mr. Brad Corcoran, City Manager City of Eden PO Box 70 Eden, NC 27289-0070 Subject: Compliance Evaluation Inspection Report and Notice of Deficiency NOD Tracking No. NOD-2019-PC-0223 NPDES Permit NC0055271 Eden Mebane Bridge WWTP, Rockingham County Dear Mr. Corcoran: On September 13, 2019, Paul DiMatteo of the Division of Water Resources (Division), Winston- Salem Regional Office met with Melinda Ward, Operator in Responsible Charge (ORC), and Chris Powell, Backup ORC, to conduct a Compliance Evaluation Inspection of the above referenced wastewater treatment plant. This inspection consists of (1) a review of the permit and accompanying documentation to determine compliance with permit conditions, and (2) an on-site inspection of several collection system components. The attached inspection form notes the areas that were evaluated for the inspection, with any notable findings outlined as follows: Summary of Non-Compliance Facility collects both influent and effluent composite samples using a constant time/constant volume method. Please note that the Permit requires facilities utilizing this method of composite sampling to be approved by the Director. If you have such an approval, please provide a copy to this office for review. You may request approval to utilize this method by responding to this letter. Note, however, that the Permit provides that “this method may only be used in situations where effluent flow rates vary less than 15 percent.” Therefore, please include daily flow charts for review with your request. Otherwise, the Permit specifies that composite samples may only be obtained by the following methods (please see the definition of “Composite Sample” under Part II, Section A): 1. Continuous – a “drip” of sample is collected continuously over a 24 hour period 2. Constant time/variable volume – a volume of sample at least 100 mL is collected at fixed time intervals, and the volume is increased based on the instantaneous flow at that moment 3. Variable time/constant volume – a volume of sample at least 100 mL is collected at fixed volume intervals. Proper set up of the sampler for flow proportional sampling generally requires connecting an interface between the sampler and flow meter. Care must be taken to ensure samples are representative of the discharge for that period. The inspector noted that the chlorine contact chambers already had flow meters installed, and encourages the operators to consult their equipment manuals to determine how appropriate composite sampling can be achieved. Requested Response Within 30 days of receipt of this letter, please submit either: a. A previous letter from the Division authorizing use of constant time/constant volume sampling, b. Your request, with sufficient accompanying documentation, to utilize constant time/constant volume sampling for review, or c. Your plan, including a timeline, to gain compliance with the flow proportional sampling requirement. If you have any questions concerning this report please contact Paul DiMatteo at (336) 776-9691 or Lon Snider at (336) 776-9800. Sincerely, Lon T. Snider, Regional Supervisor Water Quality Regional Operations Section Winston-Salem Regional Office Division of Water Resources, NCDEQ Enclosures – Inspection Report CC: WSRO Laserfiche Files EPA United States Environmental Protection Agency Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 N 52 NC0025071 19/09/13 C S31112171819 20 21 66 Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA ----------------------Reserved------------------- N67707172 73 74 75 80 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) Mebane Bridge WWTP 204 Mebane Bridge Rd Eden NC 27288 Entry Time/Date Permit Effective Date Exit Time/Date Permit Expiration Date 11:00AM 19/09/13 15/03/01 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// Melinda Sessoms Ward/ORC/336-627-1009/ Other Facility Data 01:00PM 19/09/13 18/04/30 Name, Address of Responsible Official/Title/Phone and Fax Number Brad Corcoran,PO Box 70 Eden NC 272890070/City Manager/336-623-2110/3366232726 Contacted No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Flow Measurement Operations & Maintenance Records/Reports Self-Monitoring Program Sludge Handling Disposal Facility Site Review Effluent/Receiving Waters Laboratory Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s)Agency/Office/Phone and Fax Numbers Date Paul DiMatteo DWR/WSRO WQ/336-776-9691/ Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page#1 10/11/2019 10/11/2019 NPDES yr/mo/day 19/09/13 Inspection Type C3111218 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) On flow proportional sampling - Permittee should submit a request for timed-based sampling, produce a letter previously granted by the Division, or set up the system for proper floow proportional sampling. Note that constant time/constant volume sampling may only be used when the effluent flow rate varies less than 15%; thus, Permittee should submit daily flow charts with their proposal. NC0025071 17 Page#2 Permit:NC0025071 Inspection Date:09/13/2019 Owner - Facility: Inspection Type: Mebane Bridge WWTP Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new application? Is the facility as described in the permit? # Are there any special conditions for the permit? Is access to the plant site restricted to the general public? Is the inspector granted access to all areas for inspection? Comment: Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? Is all required information readily available, complete and current? Are all records maintained for 3 years (lab. reg. required 5 years)? Are analytical results consistent with data reported on DMRs? Is the chain-of-custody complete? Dates, times and location of sampling Name of individual performing the sampling Results of analysis and calibration Dates of analysis Name of person performing analyses Transported COCs Are DMRs complete: do they include all permit parameters? Has the facility submitted its annual compliance report to users and DWQ? (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator on each shift? Is the ORC visitation log available and current? Is the ORC certified at grade equal to or higher than the facility classification? Is the backup operator certified at one grade less or greater than the facility classification? Is a copy of the current NPDES permit available on site? Page#3 Permit:NC0025071 Inspection Date:09/13/2019 Owner - Facility: Inspection Type: Mebane Bridge WWTP Compliance Evaluation Record Keeping Yes No NA NE Facility has copy of previous year's Annual Report on file for review? DMR Note - Reviewed the DMR for 9/18/2019 and noted that Effluent Zinc was reported as kg/day, and not mg/l. No conversion was made, thus this is simply a unit error. The DMRs with this fault should be corrected and resubmitted. This appears to have been present in DMRs since 6/2016. Comment: Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? Are the receiving water free of foam other than trace amounts and other debris? If effluent (diffuser pipes are required) are they operating properly? The outfall was not observed due to access issues. The operators said that they tried to get the lines crew to clear the outfall ROW but due to the time of year it was not directly accessible. Comment: Flow Measurement - Influent Yes No NA NE # Is flow meter used for reporting? Is flow meter calibrated annually? Is the flow meter operational? (If units are separated) Does the chart recorder match the flow meter? Comment: Flow Measurement - Effluent Yes No NA NE # Is flow meter used for reporting? Is flow meter calibrated annually? Is the flow meter operational? (If units are separated) Does the chart recorder match the flow meter? Flow meters are installed on the effluent sides of the 3 chlorine contact chambers and they are calibrated but not connected to SCADA and not used for flow reporting or flow proportioning. Operators said that they were suspicious of the accuracy of the meters despite them being calibrated quarterly. Comment: Bar Screens Yes No NA NE Type of bar screen a.Manual b.Mechanical Are the bars adequately screening debris? Page#4 Permit:NC0025071 Inspection Date:09/13/2019 Owner - Facility: Inspection Type: Mebane Bridge WWTP Compliance Evaluation Bar Screens Yes No NA NE Is the screen free of excessive debris? Is disposal of screening in compliance? Is the unit in good condition? Comment: Grit Removal Yes No NA NE Type of grit removal a.Manual b.Mechanical Is the grit free of excessive organic matter? Is the grit free of excessive odor? # Is disposal of grit in compliance? Comment: Secondary Clarifier Yes No NA NE Is the clarifier free of black and odorous wastewater? Is the site free of excessive buildup of solids in center well of circular clarifier? Are weirs level? Is the site free of weir blockage? Is the site free of evidence of short-circuiting? Is scum removal adequate? Is the site free of excessive floating sludge? Is the drive unit operational? Is the return rate acceptable (low turbulence)? Is the overflow clear of excessive solids/pin floc? Is the sludge blanket level acceptable? (Approximately ¼ of the sidewall depth) Two of four clarifiers are in service due to low flow. Measured the sludge depth in 1 clarifier at ~1.5 feet. Comment: Aeration Basins Yes No NA NE Mode of operation Ext. Air Type of aeration system Surface Is the basin free of dead spots? Are surface aerators and mixers operational? Page#5 Permit:NC0025071 Inspection Date:09/13/2019 Owner - Facility: Inspection Type: Mebane Bridge WWTP Compliance Evaluation Aeration Basins Yes No NA NE Are the diffusers operational? Is the foam the proper color for the treatment process? Does the foam cover less than 25% of the basin’s surface? Is the DO level acceptable? Is the DO level acceptable?(1.0 to 3.0 mg/l) DO in aeration basin 5.74 according to meter set near the end of the basin. Operators said they try to keep it above 2. Only one aeration basin is in service. Operations said they installed "solar bees," a solar-powered mixers that keep the basin in suspension near the end of the basin. They planned to install more. Comment: Disinfection-Gas Yes No NA NE Are cylinders secured adequately? Are cylinders protected from direct sunlight? Is there adequate reserve supply of disinfectant? Is the level of chlorine residual acceptable? Is the contact chamber free of growth, or sludge buildup? Is there chlorine residual prior to de-chlorination? Does the Stationary Source have more than 2500 lbs of Chlorine (CAS No. 7782-50-5)? If yes, then is there a Risk Management Plan on site? If yes, then what is the EPA twelve digit ID Number? (1000-____-____) If yes, then when was the RMP last updated? Comment: De-chlorination Yes No NA NE Type of system ?Liquid Is the feed ratio proportional to chlorine amount (1 to 1)? Is storage appropriate for cylinders? # Is de-chlorination substance stored away from chlorine containers? Comment: Are the tablets the proper size and type? Are tablet de-chlorinators operational? Number of tubes in use? Comment: Page#6 Permit:NC0025071 Inspection Date:09/13/2019 Owner - Facility: Inspection Type: Mebane Bridge WWTP Compliance Evaluation Laboratory Yes No NA NE Are field parameters performed by certified personnel or laboratory? Are all other parameters(excluding field parameters) performed by a certified lab? # Is the facility using a contract lab? # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees? Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees? DO and pH calibration records appeared acceptable. Thermometer calibration also appeared acceptable. Comment: Influent Sampling Yes No NA NE # Is composite sampling flow proportional? Is sample collected above side streams? Is proper volume collected? Is the tubing clean? # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Is sampling performed according to the permit? Sample volume is checked by staff 3x/day, was not verified during the inspection. Facility was not sampling during the inspection. Comment: Effluent Sampling Yes No NA NE Is composite sampling flow proportional? Is sample collected below all treatment units? Is proper volume collected? Is the tubing clean? # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type representative)? Sample volume is checked by staff 3x/day, was not verified during the inspection. Facility was not sampling during the inspection. Operators said they did not perform flow proportional sampling at the effluent due to difficulty in hooking the influent meter up to the effluent sampler and because, although they have effluent flow meters on each of the chlorine contact chambers, they did not believe the readings were accurate. Comment: Upstream / Downstream Sampling Yes No NA NE Page#7 Permit:NC0025071 Inspection Date:09/13/2019 Owner - Facility: Inspection Type: Mebane Bridge WWTP Compliance Evaluation Upstream / Downstream Sampling Yes No NA NE Is the facility sampling performed as required by the permit (frequency, sampling type, and sampling location)? Comment: Page#8