Loading...
HomeMy WebLinkAboutNC0044784_Compliance Evaluation Inspection_20191010DocuSign Envelope ID: 60B2E9AA-ODA7-4D35-9EA6-C231 E29DA3C1 ROY COOPER_ Grnernar a MICHAEL S. RECAN p. ; 5eererary LINDA CULPEPPER NORTH CAROLINA D+mrtor Environmental Quality October 10, 2019 James N Johnston City of Brevard 95 W Main St Brevard, NC 28712 SUBJECT: Compliance Inspection Report Cathey's Creek WTP NPDES WW Permit No. NCO044784 Transylvania County Dear Permittee: The North Carolina Division of Water Resources conducted an inspection of the Cathey's Creek WTP on 10/09/2019. This inspection was conducted to verify that the facility is operating in compliance with the conditions and limitations specified in NPDES WW Permit No. NC0044784. The findings and comments noted during this inspection are provided in the enclosed copy of the inspection report entitled "Compliance Inspection Report". There were no significant issues or findings noted during the inspection and therefore, a response to this inspection report is not required; however, the following item was noted during the inspection: The last permit update (2015) required installation of an automated flow meter, this was due to a misunderstanding of DMR data (DMRs were indicating approximately twice the actual discharge) This error has been corrected and the ORC has requested that the facility return to the manual method of estimating discharge (clarifier depth change during dewatering). If you should have any questions, please do not hesitate to contact Timothy Heim with the Water Quality Regional Operations Section in the Asheville Regional Office at 828-296-4500 or via email at tim.heim@ncdenr.gov. Sincerely, DocuSigned E� by: p� 7E617A38285848C... G. Landon Davidson, P.G., Regional Supervisor Water Quality Regional Operations Section Asheville Regional Office Division of Water Resources, NCDEQ ATTACHMENTS Ec: WQS-ARO Server LF G:\WR\WQ\Transylvania\Wastewater\Municipal\Cathey's Creek WTP 44784\Inspections\2019 CEI\20190909_NC0044784_CEI Ltr.Docx N"NCaroiinsDepartment ofEnvironmentalQualay I OINstnofWateTResourres Ashevil ie Regnnal Office 12090 U.5.70 }f� imay I Sw nsmca, North CamZn 23773 '� 32S 29C-0500 DocuSign Envelope ID: 60B2E9AA-ODA7-4D35-9EA6-C231 E29DA3C1 United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN I 2 IF I 3 I NCO044784 111 12 I 19/10/09 I17 18 I S J 19 L G] 201 I 211111 I I I I I I II I I I I I I I I I I I I I I I I I I I I I I I II I I I I I f6 Inspection Work Days Facility Self -Monitoring Evaluation Rating 131 QA ---------------------- Reserved ------------------- 671 70 I I 71 I I 72 I r I 73 I I 174 751 I I I I I I I80 u I� I I i Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES oermit Number) 01:00PM 19/10/09 15/12/01 Cathey's Creek WTP Cathey's Creek Rd Exit Time/Date Permit Expiration Date Brevard NC 28712 03:OOPM 19/10/09 20/09/30 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data Dennis Alan Richardson/ORC/828-883-8461/ Name, Address of Responsible Official/Title/Phone and Fax Number Contacted James N Johnston,95 W Main St Brevard NC 28712H828-884-2770/8288842358 No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit 0 Operations & Maintenance 0 Facility Site Review 0 Effluent/Receiving Waters Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Timothy H Heim DocuSignetl by: DWR/ARO WQ/828-296-4665/ 10 / 1 O / 2 O 19 'wtb{� Rt, Ki 11082B1 106AKA418... Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date-f D a I I [1 Sig by: 10/10/2019 ]E61]A38286848C... EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# DocuSign Envelope ID: 60B2E9AA-0DA7-4D35-9EA6-C231 E29DA3C1 NPDES yr/mo/day Inspection Type (Cont.) NCO044784 I11 121 19/10/09 117 18 JCJ Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Tim Heim of the Asheville Regional Office performed a routine Compliance Evaluation Inspection of the facility on October 9, 2019. Dennis Richardson (ORC) assisted with the inspection. The facility was generally well maintained and operated at the time of the inspection. The following item was noted during the inspection: The last permit update (2015) required installation of an automated flow meter, this was due to a misunderstanding of DMR data (DMRs were indicating approximately twice the actual discharge) This error has been corrected and the ORC has requested that the facility return to the manual method of estimating discharge (clarifier dept change during dewatering). Page# DocuSign Envelope ID: 60B2E9AA-ODA7-4D35-9EA6-C231 E29DA3C1 Permit: NCO044784 Owner - Facility: Cathey's Creek WTP Inspection Date: 10/09/2019 Inspection Type: Compliance Evaluation Permit (If the present permit expires in 6 months or less). Has the permittee submitted a new application? Is the facility as described in the permit? # Are there any special conditions for the permit? Is access to the plant site restricted to the general public? Is the inspector granted access to all areas for inspection? Comment: Operations & Maintenance Is the plant generally clean with acceptable housekeeping? Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: The facility appeared well operated and maintained at the time of the inspection. Yes No NA NE ❑ ❑ ■ ❑ ■ ❑ ❑ ❑ ❑ ■ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ Yes No NA NE ■ ❑ ❑ ❑ ❑ ❑ ■ ❑ Page# 3