Loading...
HomeMy WebLinkAbout20191352 Ver 1_PCN Form Submission_20191004DWR MOM— of Water Resources 1a. Name of project: Flex Buildings - TW Alexander 1a. Who is the Primary Contact?* Kelly Roth 1b. Primary Contact Email:* roth@mcadamsco.com Date Submitted 10/4/2019 Nearest Body of Water Stirrup Iron Creek Basin Neuse Water Classification QNSW 1c. Primary Contact Phone:* (919)361-5000 Site Coordinates Latitude: Longitude: 35.921868 -78.850071 AProcessing Information U County (or Counties) where the project is located: Durham Is this project a public transportation project?* r Yes r No 1a. Type(s) of approval sought from the Corps: * Section 404 Permit (wetlands, streams and waters, Clean Water Act) r Section 10 Permit (navigable waters, tidal waters, Rivers and Harbors Act) 1b. What type(s) of permit(s) do you wish to seek authorization? rJ Nationwide Permit (NWP) F- Regional General Permit (RGP) F Standard (IP) Pre -Construction Notification (PCN) Form September 29, 2018 Ver 3 tial Review Has this project met the requirements for acceptance in to the review process?* r Yes r No Is this project a public transportation project?* G Yes r No Qiange only if needed. BIMS # Assigned * Version#* 20191352 1 Is a payment required for this project?* * No payment required What amout is owed?* * Fee received r $240.00 r Fee needed - send electronic notification r $570.00 Reviewing Office* Select Project Reviewer* Raleigh Regional Office - (919) 791-4200 Stephanie Goss:eads\szgoss Information for Initial Review 1a. Name of project: Flex Buildings - TW Alexander 1a. Who is the Primary Contact?* Kelly Roth 1b. Primary Contact Email:* roth@mcadamsco.com Date Submitted 10/4/2019 Nearest Body of Water Stirrup Iron Creek Basin Neuse Water Classification QNSW 1c. Primary Contact Phone:* (919)361-5000 Site Coordinates Latitude: Longitude: 35.921868 -78.850071 AProcessing Information U County (or Counties) where the project is located: Durham Is this project a public transportation project?* r Yes r No 1a. Type(s) of approval sought from the Corps: * Section 404 Permit (wetlands, streams and waters, Clean Water Act) r Section 10 Permit (navigable waters, tidal waters, Rivers and Harbors Act) 1b. What type(s) of permit(s) do you wish to seek authorization? rJ Nationwide Permit (NWP) F- Regional General Permit (RGP) F Standard (IP) 1c. Has the NWP or GP number been verified by the Corps? r Yes r No Nationwide Permit (NWP) Number: Nationwide Permit (NWP) Number: NWP Numbers (for multiple NWPS): 1d. Type(s) of approval sought from the DWR: ,R 401 Water Quality Certification - Regular F Non -404 Jurisdictional General Permit F Individual Permit 39 - Commercial/Institutional Developments 12 - Utility Lines 1e. Is this notification solelyfor the record because written approval is not required? For the record only for DWR 401 Certification: For the record only for Corps Permit: r 401 Water Quality Certification - Express W Riparian Buffer Authorization 1f. Is this an after -the -fact permit application?* r Yes r No 1g. Is payment into a mitigation bank or in -lieu fee program proposed for mitigation of impacts? r' Yes r No 1g. Is payment into a mitigation bank or in -lieu fee program proposed for mitigation of impacts? r Yes r- No Acceptance Letter Attachment 1h. Is the project located in any of NC's twenty coastal counties? r Yes r No 1j. Is the project located in a designated trout watershed? O Yes r No B. Applicant Information 1d. Who is applying for the permit? W Owner W Applicant (other than owner) 1e. Is there an Agent/Consultant for this project? r- Yes r- No 2. Owner Information 2a. Name(s) on recorded deed: International Business Machine Corp. 2b. Deed book and page no.: 961-347,1107-42 2c. Responsible party: Manley James, IBM Real Estate Strategy and Operations 2d. Address Street Address 10925 David Taylor Drive Address Line 2 CKY Charlotte Postal / Zip Code 28262 2e. Telephone Number: (410)298-2600 2g. Email Address:* mjames@us.ibm.com 3. Applicant Information (if different from owner) 3a. Name: State / Rovin / Pagion NC Country USA 2f. Fax Number: r- Yes r No rYes rNo Nathan Robb 3b. Business Name: Merritt Properties 3c.Address Street Address 2066 Lord Baltimore Drive Address Line 2 cfty Baltimore Postal / Zip Code 21244 3d. Telephone Number: (410)298-2600 3f. Email Address:* nrobb@merriftproperties.com C. Project Information and Prior Project History State / Ftmince / Pegion MD Country USA 3e. Fax Number: 1. Project Information 1b. Subdivision name: (ff appropriate) 1c. Nearest municipality/ town: Durham 2. Project Identification 2a. Property Identification Number: 074903403468,074903319242, 074903414159, 074904501918 & 2b. Property size: 074904511176 51 acres 2c. Project Address Street Address 3252 S Miami Blvd. Address Line 2 Dty State / Ftmince / Pegion Durham NC Postal / Zip (ode Country 27703 USA 3. Surface Waters 3a. Name of the nearest body of water to proposed project:* Stirrup Iron Creek 3b. Water Resources Classification of nearest receiving water:* QNSW 3c. What river basin(s) is your project located in?* Neuse 3d. Please provide the 12 -digit HUC in which the project is located. 030202010801 4. Project Description and History 4a. Describe the existing conditions on the site and the general land use in the vicinity of the project at the time of this application:* The site is currently undeveloped and consists mainly of mixed pine -hardwood forest, including the Stirrup Iron Creek Tributary B floodplain which crosses the property from the northwest corner to the property's southeast corner. One sanitary sewer easement runs along the western property boundary and another runs from the northern property boundary through the center of the site to the southeastern property boundary. Please refer to the attached USGS Location Map (Figure 1), Durham County Soil Survey Map (Figure 2) and Aerial Map (Figure 3) for more information on the project setting. 4b. Have Corps permits or DWR certifications been obtained for this project (including all prior phases) in the past?* r Yes r No r Unknown 4d. Attach an 8 1/2X11 excerpt from the most recent version of the USGS topographic map indicating the location of the project site. (for DWR) MPP18020_Figure 1 USGS.pdf 1.85MB 4e. Attach an 8 1/2X11 excerpt from the most recent version of the published County NRCS Soil Survey map depicting the project site. (for DWR) MPP18020_Figure 2 Soil Survey.pdf 1.9MB 4f. List the total estimated acreage of all existing wetlands on the property: 8.578 4g. List the total estimated linear feet of all existing streams on the property: 5,500 4h. Explain the purpose of the proposed project:* The purpose of the proposed project is to provide industrial flex building space in Durham. 4i. Describe the overall project in detail, including indirect impacts and the type of equipment to be used:* The proposed development will consist of four warehouse buildings and associated parking, sidewalk, utilities and three wet pond stormwater control measures. The project includes one driveway crossing and two sanitary sewer connections that will result in permanent stream, wetland and Neuse buffer impacts. Additionally, one temporary wetland impact is proposed to allow access to a stockpile area during the construction phase. The attached Overall Impact Map (Figure 5) depicts the overall project plan view and Insets 1-4 show details of the proposed impact areas. Heavy equipment typical for road construction, utility installation and grading, such as track hoes, bulldozers, dump trucks and graders, will be used to construct the proposed project. 4j. Please upload project drawings for the proposed project. 04_MPP18020_Figure 3 Aerial Map.pdf 3.57MB 04_MPP18020_Site Plan.pdf 6.14MB 5. Jurisdictional Determinations 5a. Have the wetlands or streams been delineated on the property or proposed impact areas?* r Yes r No O Unknown Comments: 5b. If the Corps made a jurisdictional determination, what type of determination was made?* r Preliminary r Approved r Not Verified r Unknown r WA Corps AID Number: 5c. If 5a is yes, who delineated the jurisdictional areas? Name (if known): Jennifer Burdette and Kelly Roth Agency/Consultant Company: McAdams Company Other: 5d. List the dates of the Corp jurisdiction determination or State determination if a determination was made by the Corps or DWR The stream and wetland delineation was field verified by Ross Sullivan of the USACE on May 1, 2019. Receipt of the PJD is pending. The attached Figure 4 (Verified PJD Map) shows the results of the on-site verification. A Neuse buffer determination for the site was issued by DWR on May 13, 2019 (RRO #19-105). It is important to note that the Open Water Area A depicted on the PJD map (Figure 4) was present at the time the delineation was completed during wetter than normal conditions but has since receded back into the channel as shown in the photograph provided at the end of the application. 5d1. Jurisdictional determination upload 05_ MPP18020_Figure 4 PJD Map_v3.pdf 1.04MB 05_2019-05-14_MPP18020_rcvd DWR buffer determination letter.pdf 2.57MB 6. Future Project Plans 6a. Is this a phased project?* r Yes r No Are any other NWP(s), regional general permit(s), or individual permits(s) used, or intended to be used, to authorize any part of the proposed project or related activity? No D. Proposed Impacts Inventory 1. Impacts Summary 1a. Where are the impacts associated with your project? (check all that apply): W Wetlands W Streams -tributaries m Buffers r Open Waters r Pond Construction 2. Wetland Impacts W2 New sanitary sewer line P Non -Tidal Freshwater Marsh Wetland E 3e. Stream Type * Both 0.084 W3 New sanitary sewer line P Non -Tidal Freshwater Marsh Wetland E Both 0.003 (acres) 2g. Total Temporary Wetland Impact 0.011 2g. Total Wetland Impact 0.098 2h. Comments: 3. Stream Impacts 2g. Total Permanent Wetland Impact 0.087 31. Total jurisdictional ditch impact in square feet: 3a. Reason for impact (?) 3b.lmpact type * 3c. Type of impact* 3d. S. name* 3e. Stream Type * of 3gSwidth 3h. Impact(?) ❑ 95 546 3j. Comments: �[3f.Type urisdiction* 6. Buffer Impacts (for DWR) length* S1 Driveway crossing Temporary Other Stream B Intermittent Both 2 12 r Jordan Lake Average (feet) (linear feet) S2 Driveway crossing Y 9 Permanent Culvert Stream B Intermittent Both 3 41 Average (feet) (linear feet) S3 Driveway crossing Permanent Rip Rap Fill Stream B Intermittent Both 5 42 Average (feet) (linear feet) 31. Total jurisdictional ditch impact in square feet: Driveway crossing 0 StreamB 31. Total permanent stream impacts: 31. Total temporary stream impacts: 83 12 31. Total stream and ditch impacts: Stream A 95 546 3j. Comments: Other - construction access 6. Buffer Impacts (for DWR) 6a. Project is in which protect basin(s)? Q�k all that apply. V Neuse r Tar -Pamlico F Catawba r Randleman F Goose Creek r Jordan Lake C Other 6b. Impact Type 6c. Per or Temp 6d. Stream name 6e. Buffer mitigation required? 6f. Zone 7 impact 6g. Zone 2 impact Driveway crossing P StreamB No 5,195 3,148 New sanitary sewer line P Stream A No 546 609 6h. Total buffer impacts: Zone 1 Total Temporary impacts: 0.00 Zone 1 Total Permanent impacts: 5,741.00 Zone 1 Total combined buffer impacts: 5,741.00 61. Comments: Supporting Documentation 06_ MPP18020_Figure 5 Impact Maps.pdf Zone 2 0.00 Zone 2 3,757.00 Zone 2 3,757.00 1.46MB E. Impact Justification and Mitigation 1. Avoidance and Minimization 1a. Specifically describe measures taken to avoid or minimize the proposed impacts in designing the project: The applicant requested a delineation of surface waters and wetlands prior to designing a site plan to avoid and minimize impacts to these resources to the maxmum extent practicable. The 51 -acre project area contains 8.6 acres of wetland and 5,500 linear feet of stream channel. Less than 0.1 acre of wetland impacts and 95 If of stream impacts are proposed. The driveway crossing shown in Inset 1 will consist of a 5' x 8' box culvert with a riprap dissipator pad. The crossing necessitates 83 If of permanent stream impact to allow for vehicular circulation and access within the property. Of the 83 If of permanent stream impact, 42 If is for riprap fill. The culvert will be buried one foot into the stream bed to allow for aquatic life passage. The driveway crossing will also result in 5,195 sf of Zone 1 Neuse buffer impact and 3,148 sf of Zone 2 Neuse buffer impact. Two sanitary sewer connections (Insets 3 and 4) will necessitate 0.087 acres of permanent wetland impact from placing fill material in the sewer easement to allow for minimum cross and longitudinal slopes to make the easement passable for maintenance vehicles, as required by Section 7.0.III.0 of the City of Durham Reference Guide for Development. There will also be 546 sf of Zone 1 Neuse buffer impact and 609 sf of Zone 2 Meuse buffer impact associated with one sanitary sewer connection, as shown in Inset 3. Additionally, 0.011 acres of temporary wetland impact are proposed to allow access to a stock pile area during construction (see Inset 2). Construction matting will be used to minimize impacts to this area and the affected area will be reseeded with an appropriate wetland seed mix when construction is complete. 1 b. Specifically describe measures taken to avoid or minimize the proposed impacts through construction techniques: A Sediment and Erosion Control Plan for the project will be developed and approved by the City of Durham and the project will comply with the supplementary NPDES Construction Stormwater Permit (NCG010000). 2. Compensatory Mitigation for Impacts to Waters of the U.S. or Waters of the State 2a. Does the project require Compensatory Mitigation for impacts to Waters of the U.S. or Waters of the State? r Yes r No 2b. If this project DOES NOT require Compensatory Mitigation, explain why: Total stream impacts are less than 150 linear feet and wetland/stream impacts are less than 0.1 acre. Because stream and wetland impacts have been minimized to the mammum extent practicable and are below the mitigation thresholds, compensatory mitigation is not proposed. F. Stormwater Management and Diffuse Flow Plan (required by DWR) 1. Diffuse Flow Plan 1a. Does the project include or is it adjacent to protected riparian buffers identified within one of the NC Riparian Buffer Protection Rules? F Yes r No What type of SCM are you providing? F- Level Spreader F- Vegetated Conveyance (lower SHWT) F- Wetland Swale (higher SHWT) R Other SCM that removes minimum 30% nitrogen r" Proposed project will not create concentrated stormwater flow through the buffer Diffuse Flow Documentation 07_MPP18020_SCM Calcs.pdf 3.7MB 2. Stormwater Management Plan 2a. Is this a NCDOT project subject to compliance with NCDOT's Individual NPDES permit NCS000250?* r Yes 6 No 2b. Does this project meet the requirements for low density projects as defined in 15A NCAC 02H .1003(2)? r^ Yes r No 2c. Does this project have a stormwater management plan (SMP) reviewed and approved under a state stormwater program or state -approved local government stormwater program? r: Yes r No 2d. Which of the following stormwater management program(s) apply: P Local Government r State Local Government Stormwater Programs P Phase II P NSW r USMP r Water Supply Please identify which local government stormwater program you are using. City of Durham Comments: G. Supplementary Information 1. Environmental Documentation 1a. Does the project involve an expenditure of public (federal/state/local) funds or the use of public (federal/state) land?* r' Yes r No 2. Violations (DWR Requirement) 2a. Is the site in violation of DWR Water Quality Certification Rules (15A NCAC 2H .0500), Isolated Wetland Rules (15A NCAC 2H .1300), or DWR Surface Water or Wetland Standards or Riparian Buffer Rules (15A NCAC 2B.0200)?* f Yes r No 3. Cumulative Impacts (DWR Requirement) 3a. Will this project result in additional development, which could impact nearby downstream water quality?* r Yes r No 3b. If you answered "no," provide a short narrative description. The proposed project will consist of four warehouse buildings and associated parking, sidewalks, utilities and stormwater control measures and will not result in additional development. 4. Sewage Disposal (DWR Requirement) 4a. Is sewage disposal required by DWR for this project?* r Yes r Nor N/A 4b. Describe, in detail, the treatment methods and dispositions (non -discharge or discharge) of wastewater generated from the proposed project. If the wastewater will be treated at a treatment plant, list the capacity available at that plant. Sewage from the proposed project Will be directed to an ebsting City of Durham sewage treatment facility. 5. Endangered Species and Designated Critical Habitat (Corps Requirement) 5a. Will this project occur in or near an area with federally protected species or habitat?* r Yes r No 5b. Have you checked with the USFWS concerning Endangered Species Act impacts?* r Yes r No 5c. If yes, indicate the USFWS Field Office you have contacted. Raleigh 5d. Is another Federal agency involved?* r Yes r No Se. Is this a DOT project located within Division's 1-8? r Yes r No 5f. Will you cut anytrees in order to conduct the work in waters of the U.S.? r Yes r No 5g. Does this project involve bridge maintenance or removal? r^ Yes r No 5h. Does this project involve the construction/installation of a wind turbine(s)?* r Yes r No r Unknown Si. Does this project involve (1) blasting, and/or (2) other percussive activities that will be conducted by machines, such as jackhammers, mechanized pile drivers, etc.? r Yes r No 5j. What data sources did you use to determine whether your site would impact Endangered Species or Designated Critical Habitat? USFWS IPaC web tool (https://ecos.Nvs.gov/ipac/) - accessed July 23, 2019 NC Natural Heritage Program Data Explorer (http://ncnhde.natureserve.org/content/map) - accessed July 23, 2019 Consultation Documentation Upload 08_MPP18020_Flex Bldgs_T&E Review Pkg.pdf 4.44MB 6. Essential Fish Habitat (Corps Requirement) 6a. Will this project occur in or near an area designated as an Essential Fish Habitat?* r- Yes r No 6b. What data sources did you use to determine whether your site would impact an Essential Fish Habitat?* NOAA Essential Fish Habitat (EFH) Mapper (https://www.habitat.noaa.gov/application/efhmapper/indexhtml) - accessed July 9, 2019 7. Historic or Prehistoric Cultural Resources (Corps Requirement) 7a. Will this project occur in or near an area that the state, federal or tribal governments have designated as having historic or cultural preservation status?* r Yes r No 7b. What data sources did you use to determine whether your site would impact historic or archeological resources?* NC SHPO HPOWEB online tool (http://gis.ncdcr.gov/hpovveb/) - accessed July 16, 2019 In a letter dated August 20, 2019 the SHPO stated that they have "no comment' on the proposed project. 7c. Historic or Prehistoric Information Upload 09_MPP18020_Flex Bldgs SHPO Response.pdf 92.42KB 8. Flood Zone Designation (Corps Requirement) 8a. Will this project occur in a FEMA -designated 100 -year floodplain?* r Yes r No 8b. If yes, explain how project meets FEMA requirements: A Floodplain Development Application was submitted to the Durham City -County Development Review Center in September 2019 (case #: D1900211). The application documents that impacts to the floodplain Will be minimal and that there are no required regulatory protections necessary on the site. A Nationwide Permit 12 has been requested for placing FII in the FEMA floodplain to construct the sanitary sewer connections (W1 & W2). 8c. What source(s) did you use to make the floodplain determination?* FIRM Panel Numbers: 3720074900K, 3720074800K (effective 10/19/2018) Miscellaneous Comments Miscellaneous attachments not previously requested. MPP18020_Flex _OWPicture.pdf 221.68KB Signature * W By checking the box and signing below, I certify that: • I have given true, accurate, and complete information on this form; I agree that submission of this PCN form is a 'transaction" subject to Chapter 66, Article 40 of the NC General Statutes (the "Uniform Electronic Transactions Act"); • I agree to conduct this transaction by electronic means pursuant to Chapter 66, Article 40 of the NC General Statutes (the "Uniform Electronic Transactions Act"); . I understand that an electronic signature has the same legal effect and can be enforced in the same way as a written signature; AND • I intend to electronically sign and submit the PCN form. Full Name: Kelly Roth Signature Date 10/4/2019 U 004828-00013000/6718859v28 E-1 EXHIBIT E ACCESS AND CONFIDENTIALITY AGREEMENT THIS ACCESS AND CONFIDENTIALITY AGREEMENT (“Agreement ”) is made as of _________________, 2019 (the “Signature Date”), by and between INTERNATIONAL BUSINESS MACHINES CORPORATION (“Seller”) and MERRITT ACQUISITIONS, LLC (“Buyer”) and is effective as of October 1, 2018 (the “Effective Date”). BACKGROUND STATEMENT Seller and Buyer are in the process of negotiating a Real Estate Purchase and Sale Contract (the “PSA”) pursuant to which Seller will sell to Buyer certain real property located in Durham County, North Carolina and more particularly identified as real estate parcels 0748-01- 49-4407, 0749-04-51-1176, 0749-04-50-1918, 0749-03-41-4159, 0749-03-31-9242, and 0749- 03-40-3468 (the “Property”). Buyer has asked Seller to be permitted to enter the Property and commence its due diligence investigations prior to the completion and execution of the PSA. Seller has agreed to permit Buyer to do so in accordance with the terms hereof. NOW THEREFORE, in consideration of the premises contained herein and other good and valuable consideration, the receipt and sufficiency of which are hereby acknowledged, the parties hereto agree as follows: 1. Right of Access. Commencing on the Effective Date, Seller will permit Buyer and its agents, employees and contractors to enter onto the Property and to perform, at Buyer’s sole cost and expense, (i) a physical inspection of the Property in accordance with the scope of work described on Exhibit A attached hereto and made a part hereof, and (ii) such other reviews, studies, searches, tests, examinations, investigations and other information gathering activities related to the Property that Buyer deems necessary or appropriate (the “Investigations”). Buyer shall coordinate its entry onto the Property through Seller’s designated representative and shall provide reasonable prior notice of its schedule of work. Seller’s representative shall use reasonable efforts to accommodate Buyer’s schedule. Buyer shall have the right to cut trees, bushes, and other plants to obtain access to the portions of the Property it needs to access to perform the Investigations. In such event, Buyer shall use commercially reasonable efforts to disturb as little foliage as possible. Buyer shall restore the Property to substantially the condition that existed prior to the Investigations in the manner described on Exhibit A. At its expense, Buyer shall obtain all required permits from public authorities and otherwise shall comply with all laws required to carry out the Investigations. 2. Delivery of Materials. Within five (5) business days after the Signature Date, Seller shall deliver to Buyer all reports, title policies, surveys, studies, and materials in Seller’s possession with respect to the Property (the “Due Diligence Materials”) that have not been previously provided to Buyer. If the parties do not enter into the PSA or, after entering into the PSA, it is terminated for any reason, Buyer will return the Due Diligence Materials to Seller within five (5) business days after the parties cease negotiations or the termination date of the 004828-00013000/6718859v28 E-2 PSA, whichever is applicable. Seller makes no representation or warranty whatsoever as to the content of the Due Diligence Materials or whether the Due Diligence Materials are complete, comprehensive or accurate in any respect. By entering into this Agreement, Buyer acknowledges that it has no right to rely on the Due Diligence Materials and that it is understood that Buyer is expected to obtain its own reports, surveys, and studies with respect to the Property and to make its own determination of the condition of the Property, including the environmental condition thereof. Seller shall not have any liability to Buyer as a result of Buyer’s use of the Due Diligence Materials. 3. Site Sampling; Buyer’s Materials. Buyer will use S&ME Inc. to perform the geotechnical inspections and McAdams Co to perform environmental investigations and ALTA survey work. Buyer will deliver a copy of all reports it receives from them to Seller promptly after Buyer receives them, and, at Seller’s request made prior to the performance of any inspection where samples are taken, Buyer will share the samples with Seller’s corresponding engineers. Seller may distribute copies of such reports or information to consultants and others within Seller’s organization who may have a need to know such information. 4. Monitoring Wells. Buyer agrees to not to disturb any monitoring wells located on the Property during its Investigations. 5. Liability. Buyer agrees to be solely responsible for the conduct of Buyer’s agents, employees, and contractors on the Property and shall assume and pay for all expenses incurred by Buyer and Buyer’s agents, employees, and contractors in connection with the Investigations. BUYER AGREES THAT SELLER ASSUMES NO LIABILITY TO BUYER OR ANY OTHER PERSON FOR ANY INJURY, (INCLUDING DEATH) TO PERSONS OR DAMAGE TO OR LOSS OF PROPERTY SUFFERED ON THE PROPERTY UNLESS CAUSED BY THE MISCONDUCT OR NEGLIGENT ACT OR OMISSION OF SELLER, ITS EMPLOYEES OR INVITEES. SELLER MAKES NO REPRESENTATION OR WARRANTY OF ANY KIND, WRITTEN OR ORAL, AS TO THE PROPERTY’S CONDITION OR ITS FITNESS FOR ANY PURPOSE. 6. Insurance. Prior to any physical entry onto the Property, Buyer shall deliver to Seller evidence reasonably satisfactory to Seller that it has obtained comprehensive general liability insurance naming Seller as an additional insured in an amount of not less than $2,000,000.00 for bodily injury (including death) and not less than $1,000,000 for property loss or damage, and written on such forms as are reasonably acceptable to Seller. Such insurance shall include coverage for the contractual liability assumed by Buyer pursuant to this Agreement, and shall be primary and noncontributory. 7. Indemnity. Buyer shall hold harmless and indemnify Seller, its agents, employees, contractors, tenants, and venturers from any and all damages, claims, losses and liabilities (including, without limitation, reasonable legal fees and expenses) arising out of any claims of alleged injury to any person (including death) or damage to or loss of any property or 004828-00013000/6718859v28 E-3 of environmental noncompliance, if such injury, death, damage or loss is caused or is alleged to have been caused on or about the Property by acts or omissions of Buyer or its officers, employees, agents, or contractors. The foregoing indemnity shall not apply to any liability, cost or expense arising out of the mere discovery of existing conditions on the Property as a result of Buyer's investigations, unless such condition was caused by Buyer, or its officers, employees, agents, or contractors. 8. Confidentiality. a As used herein, “Confidential Information” shall mean: i Due Diligence Materials and all other written information furnished to Buyer or Buyer’s Representatives (hereinafter defined) to enable completion of the Investigations including, without limitation, analyses, cost information, reports, budgets, proformas, contracts, agreements, studies, plans and specifications, and marketing strategies or operations, in each case furnished by or on behalf of Seller or its directors, officers, employees, affiliates, consultants (including, without limitation, Seller’s financial advisors, attorneys and accountants) partners or agents; and ii Any letter of intent, offer to purchase, purchase and sale agreement, or similar document and their terms. b The words “Confidential Information” shall not include information contained in the Due Diligence Materials that: (a) was available to Buyer on a non-confidential basis prior to its disclosure by Seller; (b) becomes available to Buyer on a non-confidential basis from a source other than Seller under circumstances where such source is entitled to make such disclosure; or (c) is disclosed in accordance with Section 7(d) below. c Buyer shall keep all Confidential Information strictly confidential; provided, however, that the Confidential Information may be disclosed to Buyer’s directors, officers, or employees, as well as its counsel, geotechnical and engineering vendors, accounting firms, mortgage brokers, joint venture partners, and financial institutions who need to know such information for the purpose of assisting Buyer with its inspection of the Property (“Buyer’s Representatives”). Buyer’s Representatives shall be informed by Buyer of the confidential nature of the Confidential Information and shall be directed by Buyer to treat such information with strict confidence. The foregoing shall not prohibit Buyer from using any of the Due Diligence Materials or other reports and materials developed by it to enter into the North Carolina Brownfields program or take any action with respect thereto or to satisfy any other condition to closing set forth in the PSA. d If Buyer or any of Buyer’s Representatives are requested pursuant to, or become compelled by, applicable law, regulation or legal process to disclose any of the Confidential Information in a particular matter, such party will provide Seller with 004828-00013000/6718859v28 E-4 prompt written notice and will assist Seller to seek protection of the Confidential Information by protective order or otherwise at its sole expense. e Without Seller’s prior written approval, except to the extent necessary in connection with the Brownfields Agreement, site plan approval process or in connection with similar development matters that will not be binding on Seller if Buyer does not purchase the Property, Buyer and Buyer’s Representatives will not (except as required by applicable law, regulation or legal process, and only after compliance with Section 4), disclose to any individual, partnership, trust, corporation or other entity (collectively, “Person”) the fact that Confidential Information exists or has been made available, or that the Investigations and discussions with respect thereto are taking or have taken place, or any term, condition or other fact relating to the Property including without limitation, the status thereof. f Buyer acknowledges and agrees that Seller will have no adequate remedy at law if Buyer violates any of the confidentiality requirements of this Agreement. In such event, Seller will have the right to seek injunctive relief to restrain any breach or threatened breach of the confidentiality requirements by Buyer, specific enforcement of the confidentiality requirements of this Agreement, and all other remedies available to Seller at law or in equity. In the event that Seller prevails in its enforcement of the confidentiality requirements of this Agreement, Buyer shall also be liable for the payment of Seller’s reasonable attorneys’ fees and court costs. 9. Government Authorities. Buyer shall not submit any application to, or impose any restrictions on the Property that will be binding on Seller if Buyer fails to purchase the Property, and except for actions in connection with the Brownfields Agreement as described in the PSA, obtaining site plan approval, or similar development matters that will not be binding on Seller if Buyer does not purchaser the Property, Buyer will not appear before public meetings or hearings of any governmental authority with respect to the Property. 10. Term. The obligation of confidentiality described in Section 8 shall end one (1) year from the later (if applicable) to occur of (i) the Signature Date, (ii) Buyer purchases the Property or (iii) any formal agreement to Purchase the Property is terminated. All other terms of this Agreement shall remain in full force and effect until the earlier of (a) the parties discontinue negotiations to enter into a PSA, (b) the PSA is terminated or closing occurs thereunder, (c) such other date specified in the PSA or by a written agreement signed by both Seller and Buyer, or (d) Seller gives Buyer written notice of termination of this Agreement. 11. Assignment. Neither this Agreement nor the permission and privileges granted herein are assignable or transferable and are limited to Buyer and Buyer’s Representatives, and any purported assignment or transfer is automatically void and of no force or effect. 004828-00013000/6718859v28 E-5 12. Notices: All notices, demands and other communications hereunder shall be in writing and shall be delivered personally against receipt, or by registered or certified mail, postage prepaid and return receipt requested, or by a nationally recognized overnight delivery service, in each case addressed to the parties as follows: As to Buyer: Merritt Acquisitions, LLC 2066 Lord Baltimore Drive Baltimore, Maryland 21244 Attention: Robb L. Merritt email: rmerritt@merrittproperties.com with copy to: Cynthia A. Berman, Esquire Kramon & Graham, P.A. One South Street, Suite 2600 Baltimore, Maryland 21201 email: cberman@kg-law.com As to Seller: International Business Machines Corporation IBM Real Estate Strategy and Operations 10925 David Taylor Drive Charlotte, NC 28262 Attention: Manley James email: mjames@us.ibm.com with copy to: International Business Machines Corporation Global Real Estate Operations 1 New Orchard Road Armonk, NY 10504 Attention: Real Estate Counsel email: thaler@us.ibm.com Any notice delivered in accordance herewith shall be deemed received on the date sent, if sent by hand delivery; one (1) Business Day after the date sent, if sent by overnight commercial delivery service; and three (3) days after the date sent, if sent by USPS certified mail. Additionally, notices may be given by electronic transmission, which shall be deemed delivered on the date of such transmission, provided that an original copy of said transmission shall be delivered to the addressee by a nationally recognized overnight delivery service on the day following such transmission. Failure to send a copy of any notice to the person designated above to receive a copy of notices shall not affect the validity of any notice. 13. Miscellaneous. This Agreement shall be governed by, and construed in accordance with, the laws of the State of North Carolina without regard to principles of conflicts of law. This Agreement may be executed in two or more counterparts, each of which shall be deemed to be an original and all of which counterparts when assembled shall constitute a single 004828-00013000/6718859v28 E-6 agreement. An electronic signature of either party upon this Agreement shall be deemed valid and binding and admissible by either party against the other. No party shall have any liability to the other for any punitive, consequential, extraordinary or special damages, even if the non- damaged party had notice of the potential for such damage to the other party. Signature Page to Follow IN WITNESS WHEREOF, the parties have executed this Agreement, intending to be bound as of the Effective Date. SELLER: INTERNATIONAL BUSINESS MACHINES CORPORATION By: Q"w� Name: e-'�- Title: 5-g_ eRaSl-%A, ,,A,(� 2 Date: H ;17��1B / vat Y , 2019 BUYER: MERRITT ACQUISITIONS, LLC Robb L. Merritt, President Date: , 2019 004828-00013000/6718859v28 E-7 004828-00013000/6718859v28 E-8 EXHIBIT A Scope of Review Geotechnical Services: ● S&ME personnel will perform a site reconnaissance to mark boring locations and document existing site conditions. Boring locations, shall be in accordance with EXHIBIT ‘B’ attached hereto and, will be marked in the field with a handheld GPS device. ● S&ME will review publicly available investigatory / remedial information related to the contamination from the adjoining property formerly owned by Weck to include existing well depths etc., prior to the installation of any borings so as not to penetrate any existing confining layer(s) and create new pathways for contaminant migration. S&ME shall maintain a minimum 10’ buffer to any existing groundwater wells currently located and identified on the Property. ● S&ME will coordinate all access to the Property with Stuart Hurwitz, Advisory Environmental Engineer, IBM Research Triangle Park, phone: 919.254.0810, T/L 444; mobile: 919.355.8856; email: hurwitz@us.ibm.com ● S&ME will subcontract personnel and equipment (hydro-axe) to perform low- impact clearing to provide access paths for drilling equipment, including clearing and mulching of trees. ● S&ME, Inc. will contact NC 811 to mark member utilities near proposed test locations. ● Twenty-five soil test borings with standard penetration testing (SPT) will be performed to the depths up to 50’. ● Samples of subsurface soils will be taken at 2½-foot intervals above a depth of 10 feet and at 5-foot intervals below 10 feet using a split-spoon sampler. Standard Penetration Tests (SPT) will be conducted in conjunction with split-spoon sampling in general accordance with ASTM D1586-11. Measurements of groundwater levels will be taken at the termination of each boring and after 24 hours at select borings. After water levels are taken, borings will be backfilled with bentonite pellets in the northern portion of the site and auger cuttings in the remainder of the site. A borehole closure device will installed in each boring. The work described in this section will involve the drilling of boreholes on the Property. S&ME will use borehole closure appliances to improve the stability of the surface in the vicinity of completed boreholes. S&ME will close the borehole made in this study using the standard as described in EXHIBIT ‘C’ attached hereto as North Carolina Department of Environmental Quality (NCDEQ) closure requirements under 15A NCAC subchapter 2C - Well Construction Standards; and more specifically sections 15A, NCAC 02C.0113 – Abandonment of Wells. 004828-00013000/6718859v28 E-9 Surface Water/ Wetland Delineation. ● A detailed delineation of surface waters and wetlands present on the tract will be completed in general accordance with 1987 Corps of Engineers Wetland Delineation Manual and the appropriate regional supplement and the NC Division of Water Resources Methodology for Identification of Streams. Sequentially numbered flags will be hung around the boundaries of wetlands and at the start/end points of stream channels. ● Perform a field survey of jurisdictional streams and wetlands based on final delineation prepared under Task A4.70. Features to be located include individual wetland flags, centerline of stream, and top of banks for the jurisdictional streams. Phase I Environmental. McAdams will complete a PESA for the subject site. The PESA will be conducted to meet the requirements of 40 CFR Part 312, Standards and Practices for All Appropriate Inquiry, ASTM E1527-13, Standard Practice for Environmental Site Assessments: Phase I Environmental Site Assessment Process (the Standards), and, in accordance with contracted terms and conditions. ATLA/ NSPS Land Title Survey: Perform ALTA/NSPS Land Title Survey of the Property based on the Minimum Standard Detail Requirements for ALTA /NSPS Land Title Surveys adopted in 2016 including the following Table A items: 1, 2, 3, 4, 5, 7(a), 7(b1), 7(c), 8, 9, 13, and 16. 1111 MCADAMS AGENT AUTHORIZATION FORM All Blanks To Be Filled In By The Current Contract Purchaser PIN: 0749-03-31-9242, 0749-03-41-4159, 0749-04-51-1176, 0749-04-50-1918 & 0749-03- 40-3468 Property Owner Name: Merritt Properties Property Owner Address: 2066 Lord Baltimore Drive, Baltimore, MD 21244; POC: Nathan Robb Property Owner 410-298-2600/nrobb@merrittproperties.com Phone/Email: Flex Buildings — TW Alexander Project Name: Project Number: MPP -18020 Stan Wingo/Jennifer Burdette Project Manager: Attn: Ross Sullivan US Army Corps of Engineers Raleigh Regulatory Field Office 3331 Heritage Trade Drive, Suite 105 Wake Forest, NC 27587 Re: Wetlands Related Consulting and Permitting To Whom It May Concern: Attn: Karen Higgins NC Division of Water Resources 401 & Buffer Permitting Branch 512 N. Salisbury Street Raleigh, NC 27604 I hereby designate and authorize The John R. McAdams Company, Inc. to act in my behalf as my agent in the processing of permit applications, to furnish upon request supplemental information in support of applications, etc. from this day forward. I, the undersigned, a duly authorized owner of record of the property/properties identified herein, do authorize representatives of the Wilmington District, U.S. Army Corps of Engineers (Corps) and NC Division of Water Resources to enter upon the property herein described for the purpose of conducting on-site investigation and issuing a determination associated with Water of the U.S. subject to Federal jurisdiction under Section 404 of the Clean Water Act/Section 10 of the Rivers and Harbors Act of 1899 and/or Waters of State and/or Riparian Buffer Rules. This notification supersedes any previous correspondence concerning the agent for this project. NOTICE: This authorization, for liability and professional courtesy reasons, is valid only for government officials to enter the property when accompanied by The John R. McAdams Company, Inc. staff. Print Contractor Purchaser Signatu 03. Date creating experiences through experience 2905 Meridian Parkway, Durham, NC / 919. 361 5000 0 2,0001,000 Feet1 inch = 2,000 feet $ FIGURE 1. USGS TOPOGRAPHIC MAPFLEX BUILDINGS - TW ALEXAND ERDURHAM, DURHAM COUNTY, NC NOTES:1. USGS; 7.5 MINUTE, QUAD, DURHAM SE, NORTH CAR OLINA; 20162. LAT: 35.921868, LONG: -78.850071 11/6/2018 burdetteMPP-18020DATE:JOB NO:DRAWN BY: X:\Projects\MPP\MPP-18020\Storm\Wetlands\GIS\MPP18020_Figure 1 USGS.mxd, 11/6/2018 2:39:06 PM, burdette PR OJECT AREA 1VERSION: 0 1,320660Feet1 inch = 1,320 feet $ FIGURE 2. NRCS SOIL SURVEYFLEX BUILDINGS - TW ALEXAND ERDURHAM, DURHAM COUNTY, NC NOTES:1. NRCS; SOIL SURVEY SH EET 32 AN D 36, DURHAM COUNTY, NC2. LAT: 35.921868, LONG: -78.850071 X:\Projects\MPP\MPP-18020\Storm\Wetlands\GIS\MPP18020_Figure 2 Soil Survey.mxd, 11/6/2018 3:07:40 PM, burdette PR OJECT AREA 11/6/2018 burdetteMPP-18020DATE:JOB NO:DRAWN BY: 1VERSION: 7v - 1_4 A dw%,k­ k '011.0 4 44 '14 A$. At 4 ZAI Op i PT ;1 aw v AV .46 XY jo; — - ", 4 f Ap P* .4 if 40 r 7 1;044 l - O_x e IF. ?,#o A qL ----------- VIP do. .......... Source Me, Geo Eye, Earth star G;ogdp�hi. ONES-Mirbus IDS, USq& USGSr "t p . tr6pG dIL A, Mu I'll, :'IS User Community a ------ -- -- ---- -- EJC I STyN G HILLDR VE I `VARIAB-ILE, WtDTH / CONROLLED ACCE�5 R/W)�� v � 3700 S MIAMI BLVD _ ,PIN: 0749-38-96-9739 SE!IND/IN Fd TECH TELCOMM`- / I ZONIN IL �I TIER: SUBURBAN � n o I R=770 L=263. --�----:,----------------------------------- —=-----�'---------- -----------� -------------- ------------------------- 3039 E CORNWALLIS RD USEI --' PIM 0748-03-27-3425 . \ � � ND/INFO TECH-TELCOM.M i ZONING:SRP TIER: SUBURBAN 25' REAR YARD SF – -- – TBACK i S" SD Y _ SO / 4t -L=50.6884 \ f V b / / _v v 6 \ \ / VARIABLE WIDTH � PUBLIC ACCESS EASEMENT NORTH CAROLINA' I I RAILROAD 200' RAIL R 1 I I I j NO'45'50"E 57R99'4 -------- r---- — -- — v �YfM) 46' STREET Y�� - v r BUILDIIN\ M /w v vQ (4v FFE=.25 � '� v� 10' �f�0–BUIL � � �. , � � 10' NO BUIL Ss I UK y SETBACK 10' MULTI–USEYP.) ; JASPHALT 'TRAIL TYP: v M 50' RIPARIAN BUFFER (MEAS1JRED 50 FROM OF BANK, EACH SIDE) i v /� 4001 STIRRUP CREEK DRIVE PIN: b748-02-59-3645 � '� i I � 10 MULTI -USE USE: COM/WHSE STORAgn ( ) �� I . ZONING IL ASPHALT TRAM TYP. \ B 4U� mak, A � ' �_ � TIER: SUBURBAN '�� -- , _ VARIABLE WIDTH v� V� 9b PUBLIC ACCESS v v\\V��� M \ EASEMENT v" RETAINING WALL v � I WITH FENCE (4� / (DESIGN BY OTHERS) r 3211-5 MIAMI BLVD A � 0749-04-50-5259 24.05'49"w v\ sy ,I \ ZONING: IL �� , 122.57 I TIER: SUBURBAN 3207SMIAMI BLVD I_ PIN: -,0749-04-50-3655 ZONING. -USE: VAC RES/<100 ACRE (41)S _ /� .V� TIER: SUBURBAN ' I � y 32015 MIAMI BSL -VD, PIN: 0749-04-50-3758 f�� USE: RES/1-FAMILY � _ = V � \� ZONING. IL TIER: SUBURBAN \ (3123-5 MlA BLVD -� '-� PIN:0749-04-50-49F5 \� „j / USE RES/1-FAMILY r -ZONING: _ VAV GQ TIER: SUBURBAN I i i — — I---------,� ---------------- El II PIN2910WECKDR 07490342-0213 USE / 'IINDINI-0 TECH-TELCOMM ZONING: IL I TIER: SUBURBAN a SISI SID N89'51'2 "E 22.09' -_ 2928 WTCR DR - — - - PIN 0749 03 41 1792 _R SSE:VACANT INDUSTRIAL eR�ATII 6 / ZONING IL - - ' TIER: SUBURBAN S70'02'36/E' 129.94' 1 S82- '07"E ioJl�; m ' I cc i; J W / Q) m / z N0p `J l , 1 'x r►— vi I I 2917 WECK DR PIN: 0749-04-42-7006 1� USE: VACANT INDUSTRIAL ZON1,NG: tP TIERzSUBURBAN �ERMANENT SLOPE ASEMEI�Y�T kNC, DOT PROJECT #U -5309B S7T36'42"E 0.54' / TREE /II - A 1 VE�RAGGE /I AREA � �- I # ( s2/ SF) )' STRE / 3020SMIAMI BLVo� kRD/ PIN:0749-04-51-3603 USE: COM/OFFICE BLDG \ ZONING: CIN / TIER: SUBURBAN ANENJ DRAINAG� IN 4o G 742 / I � v \ / GRADING LEGEND ■ 250.50 250.00 FLARED END SECTION ENDWALL SECTION CATCH BASIN DROP INLET STORM SERVICE INLET STORM SERVICE ROOF–DRAIN JUNCTION BOX DRAINAGE FLOW ARROW LINE BREAK SYMBOL TOP & BOTTOM CURB ELEVATIONS \TW=223.00 TOP OF WALL ELEVATION BW=213.00 BOTTOM OF WALL ELEVATION (NOTE: BOTTOM OF WALL IS GROUND ELEVATION NOT WALL FOUNDATION) + 250.60 SPOT ELEVATION STORM DRAINAGE STORM SERVICE LINE RD RD RD ROOF DRAIN, 8" ADS NON–PERFORATED TUBING OR EQUAL 1.0% MIN. SLOPE 3' MIN. COVER PVC SCHEDULE 40 IN . I a ------ -- -- ---- -- EJC I STyN G HILLDR VE I `VARIAB-ILE, WtDTH / CONROLLED ACCE�5 R/W)�� v � 3700 S MIAMI BLVD _ ,PIN: 0749-38-96-9739 SE!IND/IN Fd TECH TELCOMM`- / I ZONIN IL �I TIER: SUBURBAN � n o I R=770 L=263. --�----:,----------------------------------- —=-----�'---------- -----------� -------------- ------------------------- 3039 E CORNWALLIS RD USEI --' PIM 0748-03-27-3425 . \ � � ND/INFO TECH-TELCOM.M i ZONING:SRP TIER: SUBURBAN 25' REAR YARD SF – -- – TBACK i S" SD Y _ SO / 4t -L=50.6884 \ f V b / / _v v 6 \ \ / VARIABLE WIDTH � PUBLIC ACCESS EASEMENT NORTH CAROLINA' I I RAILROAD 200' RAIL R 1 I I I j NO'45'50"E 57R99'4 -------- r---- — -- — v �YfM) 46' STREET Y�� - v r BUILDIIN\ M /w v vQ (4v FFE=.25 � '� v� 10' �f�0–BUIL � � �. , � � 10' NO BUIL Ss I UK y SETBACK 10' MULTI–USEYP.) ; JASPHALT 'TRAIL TYP: v M 50' RIPARIAN BUFFER (MEAS1JRED 50 FROM OF BANK, EACH SIDE) i v /� 4001 STIRRUP CREEK DRIVE PIN: b748-02-59-3645 � '� i I � 10 MULTI -USE USE: COM/WHSE STORAgn ( ) �� I . ZONING IL ASPHALT TRAM TYP. \ B 4U� mak, A � ' �_ � TIER: SUBURBAN '�� -- , _ VARIABLE WIDTH v� V� 9b PUBLIC ACCESS v v\\V��� M \ EASEMENT v" RETAINING WALL v � I WITH FENCE (4� / (DESIGN BY OTHERS) r 3211-5 MIAMI BLVD A � 0749-04-50-5259 24.05'49"w v\ sy ,I \ ZONING: IL �� , 122.57 I TIER: SUBURBAN 3207SMIAMI BLVD I_ PIN: -,0749-04-50-3655 ZONING. -USE: VAC RES/<100 ACRE (41)S _ /� .V� TIER: SUBURBAN ' I � y 32015 MIAMI BSL -VD, PIN: 0749-04-50-3758 f�� USE: RES/1-FAMILY � _ = V � \� ZONING. IL TIER: SUBURBAN \ (3123-5 MlA BLVD -� '-� PIN:0749-04-50-49F5 \� „j / USE RES/1-FAMILY r -ZONING: _ VAV GQ TIER: SUBURBAN I i i — — I---------,� ---------------- El II PIN2910WECKDR 07490342-0213 USE / 'IINDINI-0 TECH-TELCOMM ZONING: IL I TIER: SUBURBAN a SISI SID N89'51'2 "E 22.09' -_ 2928 WTCR DR - — - - PIN 0749 03 41 1792 _R SSE:VACANT INDUSTRIAL eR�ATII 6 / ZONING IL - - ' TIER: SUBURBAN S70'02'36/E' 129.94' 1 S82- '07"E ioJl�; m ' I cc i; J W / Q) m / z N0p `J l , 1 'x r►— vi I I 2917 WECK DR PIN: 0749-04-42-7006 1� USE: VACANT INDUSTRIAL ZON1,NG: tP TIERzSUBURBAN �ERMANENT SLOPE ASEMEI�Y�T kNC, DOT PROJECT #U -5309B S7T36'42"E 0.54' / TREE /II - A 1 VE�RAGGE /I AREA � �- I # ( s2/ SF) )' STRE / 3020SMIAMI BLVo� kRD/ PIN:0749-04-51-3603 USE: COM/OFFICE BLDG \ ZONING: CIN / TIER: SUBURBAN ANENJ DRAINAG� IN 4o G 742 / I � v \ / GRADING LEGEND ■ 250.50 250.00 FLARED END SECTION ENDWALL SECTION CATCH BASIN DROP INLET STORM SERVICE INLET STORM SERVICE ROOF–DRAIN JUNCTION BOX DRAINAGE FLOW ARROW LINE BREAK SYMBOL TOP & BOTTOM CURB ELEVATIONS \TW=223.00 TOP OF WALL ELEVATION BW=213.00 BOTTOM OF WALL ELEVATION (NOTE: BOTTOM OF WALL IS GROUND ELEVATION NOT WALL FOUNDATION) + 250.60 SPOT ELEVATION STORM DRAINAGE STORM SERVICE LINE RD RD RD ROOF DRAIN, 8" ADS NON–PERFORATED TUBING OR EQUAL 1.0% MIN. SLOPE 3' MIN. COVER PVC SCHEDULE 40 IN TRAFFIC AREAS —TP—TP—TP—TREE PROTECTION FENCE LD LD LIMITS OF DISTURBANCE WOODED AREA 250 MAJOR CONTOUR 252 MINOR CONTOUR _ ___ 250_______ EXISTING MAJOR CONTOUR -------252------- EXISTING MINOR CONTOUR — — EASEMENT LINE ACCESSIBLE PARKING AREA (2% MAX. SLOPE IN ALL DIRECTIONS) WETLAN DS TREE CONSERVATION AREA UNMAPPED NON—ENCROACHMENT AREA I r wA•01 1 `�� �I \ 1 'r \ f v V S C33. GRAPHIC SCALE 0 50 100 200 1 inch = 100 ft. LIMITS OF DISTURBANCE = 43.00 AC. SEE SHEET C0.01 FOR ALL PROJECT, SITE, GRADING, STORM DRAINAGE AND UTILITY NOTES ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE CURRENT CITY OF DURHAM ENGINEERING DESIGN AND CONSTRUCTION STANDARDS PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION 'J McADAMS The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293 www.mcadamsco.com CLIENT MERRITT PROPERTIES 2066 LORD BALTIMORE DRIVE BALTIMORE, MARYLAND 21244 merritt CONSTRUCTION SERVICES 2066 LORD BALTIMORE DRIVE BALTIMORE, MD 21244 PHONE 410.298.2600 FAX: 410-298.9644 www.MerrittProperties.com W 0 9:1- :1-Zz_j _j aw X LUJ W M 1 0 Q zN Qa z_ J W oC � a U LTJ O � z G < a 1 Ln 0 -z D Co 2 0 X a W LL CAR ,',' % wXktg J .; REVISIONS NO. DATE 1 09. 11. 2019 RESPONSE TO 1ST SITE PLAN REVIEW PLAN INFORMATION FILENAME MPP18020-SITE-OAG1 CHECKED BY LAW DRAWN BY CGH SCALE 1"=100' DATE 06. 28. 2019 SHEET OVERALL GRADING AND STORM DRAINAGE PLAN C3.00 - ----------1--�--- - - - - - = NO'43'54"E — - - - - -1320-.80' ISTING DUKE �\ 40' STREET ENERGY TOWER DUKE ENERGY PROGRESS � k I YARD 68' TRANSMISSION R/W / j EXISTING DUKE I I�.B�3i7, F�419 ENERGY TOWER — 0 i , i � I � 10'x70' SIGHT DISTANCE / / LD LD TRIANGLE (TYP.) _ / / I -D �i LD LD LD LD 376 LD LD LD - -------------- / CATCH BASIN 20' SCM ACCESS AND --7\ � — tea ��-- ------ --------------------- --------------- LD\ LD LD -----LD _ `TYP.).- MAINTENANCE EASEMENT 0 1 ------------- -- 0 I no 372 I� _Nf7'16'14"W —I� \ 288.11' �, I J CATCH BASIN — I ------------—(TYP.) — — — — — — — — — — — — — — 37005 MIAMI BLVD �' o PIN: 0748-38-96-9739,I 9 I c USE: IND/INFOFOTETECH-TELCOMM I � — — — — — — — — — — — --- — — — — — — — — — ZONING: IL TIER: SUBURBAN / I 370 I I o /I I/ _ J BUILC I / I �► \ 9� — C II I I I_ FFE=37: �I U I II` v 1 W� \U wW I J \ o' II ?� Cc I► hC) �- I I ' -"rU I _ i-LKI 11 o � . I J 40' E T \ co / Q ' YARD 366 r CATCH BASIN_-FUTUR€ FEMA 100 YEAR/1% (TYP — ANNUAL CHANCE FLOOD MAPPED PER SURVEY- i Tr1Pn(1RAPHY 362 0 / 0 362 360 — 3 8 / di m/dl — OT/dl — a1I a1/di m/di — m/dl — m/di a-1/�U = an/a.L m/dl m/di — 10'x70' SIGHT DISTANCE Iai �Iai TRIANGLE (TYP LOT - 2- 48.81 AC / 25' JURISDICTION. WETLAND BUFFER (TYP.) �� �� v NON `EN ACH - SY 30 IDE YARD i o N9 A SETBACK 37'28"E SEE S - El2.27 Ac r .� S Sy - > X SEE SHEET THIS SHEET / WETLA o , L J l 25 ,JURR S 'IETIONA� -, riN (TYP.) �I 40 S RET_/ /SE�AK'lT P. / ` �R I J / / M , 3T ACK o YARD cv in Nb_00A \ \ Ln LOT 2 TLr:�\ iAREAEXISTING HILL DRIV ' 48.81 AC 7L (VARIABLE WIDTH �7_AG CONTROLLED ACCESS R/ ) r 4A C l^ , N � YR� TP _-To Lam— _, U OU OU 0 r , _ — — � — T�— U / TC SD OU SD OU U o SD d-- `. — 0 FO — - FO FO FO FO �a a al — — — — — FO SFO - / II C �— al al al tel— al al al al — — — ,— — — -- —0.i = al EXISTING ��� 5° N S MIAMI BLVD N 4 II S.R. 1959 15'x555' AASHTO / 100' PUBLIC R/W) SIGHT DISTANCE ( ( c c �� c —� _� ,� ° _(h17— —(Ar1— `—(Nt��/ (nn) (M) (N� ( ( ( ( TR I A NG (M) I— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — - GRADING LEGEND 0 FLARED END SECTION RD RD RD ENDWALL SECTION CHECKED BY CATCH BASIN DRAWN BY DROP INLET ■ STORM SERVICE INLET DATE STORM SERVICE ROOF -DRAIN ® JUNCTION BOX �-y DRAINAGE FLOW ARROW ti LINE BREAK SYMBOL 250.50 MAJOR CONTOUR TOP & BOTTOM CURB ELEVATIONS 250.00 -------250------- \,\TW=223.00 TOP OF WALL ELEVATION BW=213.00 BOTTOM OF WALL ELEVATION EASEMENT LINE (NOTE: BOTTOM OF WALL IS GROUND ACCESSIBLE PARKING AREA ELEVATION NOT WALL FOUNDATION) + 250.60 SPOT ELEVATION STORM DRAINAGE SEE SHEET C3.02 — LD LD LD LD --- di -7—E,4/di , —--------------- <—�-- — � 46 °fid Z0 E E E E E WETLANDS E E E E E E C TREE CONSERVATION AREA 1 r � UNMAPPED NON -ENCROACHMENT AREA 6 z I V / . z GRAPHIC SCALE 0 20 40 80 1 inch = 40 ft. SEE SHEET C0.01 FOR ALL PROJECT, SITE, GRADING, STORM DRAINAGE AND UTILITY NOTES ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE CURRENT CITY OF DURHAM ENGINEERING DESIGN AND CONSTRUCTION STANDARDS PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION 'J McADAMS The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293 www.mcadamsco.com CLIENT MERRITT PROPERTIES 2066 LORD BALTIMORE DRIVE BALTIMORE, MARYLAND 21244 'N merritt CONSTRUCTION SERVICES 2066 LORD BALTIMORE DRIVE BALTIMORE, MD 21244 PHONE 410.298.2600 FAX: 410-298.9644 www.MerrittProperties.com W 0 9:1- :1-Zz_j _j aW W W J M 1 0 Q z N Qa z J W � a U � � 2 W � z G < a Ln 0 -z D - Co 2 0 X a W Ij LL ,, CAR ,' - i �v = -_ 2 - . G I NE--'_�R', - Q��'�qY wATSON'�.�'. REVISIONS NO. DATE 1 09. 11. 2019 RESPONSE TO 1ST SITE PLAN REVIEW PLAN INFORMATION PROJECT NO. STORM SERVICE LINE RD RD RD ROOF DRAIN, 8" ADS CHECKED BY NON -PERFORATED TUBING OR DRAWN BY EQUAL 1.0% MIN. SLOPE 3' MIN. SCALE COVER PVC SCHEDULE 40 IN DATE TRAFFIC AREAS —TP—TP—TP— TREE PROTECTION FENCE LD LD LIMITS OF DISTURBANCE WOODED AREA 250 MAJOR CONTOUR 252 MINOR CONTOUR -------250------- EXISTING MAJOR CONTOUR 252 EXISTING MINOR CONTOUR — — EASEMENT LINE ACCESSIBLE PARKING AREA (2% MAX. SLOPE IN ALL DIRECTIONS) — LD LD LD LD --- di -7—E,4/di , —--------------- <—�-- — � 46 °fid Z0 E E E E E WETLANDS E E E E E E C TREE CONSERVATION AREA 1 r � UNMAPPED NON -ENCROACHMENT AREA 6 z I V / . z GRAPHIC SCALE 0 20 40 80 1 inch = 40 ft. SEE SHEET C0.01 FOR ALL PROJECT, SITE, GRADING, STORM DRAINAGE AND UTILITY NOTES ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE CURRENT CITY OF DURHAM ENGINEERING DESIGN AND CONSTRUCTION STANDARDS PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION 'J McADAMS The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293 www.mcadamsco.com CLIENT MERRITT PROPERTIES 2066 LORD BALTIMORE DRIVE BALTIMORE, MARYLAND 21244 'N merritt CONSTRUCTION SERVICES 2066 LORD BALTIMORE DRIVE BALTIMORE, MD 21244 PHONE 410.298.2600 FAX: 410-298.9644 www.MerrittProperties.com W 0 9:1- :1-Zz_j _j aW W W J M 1 0 Q z N Qa z J W � a U � � 2 W � z G < a Ln 0 -z D - Co 2 0 X a W Ij LL ,, CAR ,' - i �v = -_ 2 - . G I NE--'_�R', - Q��'�qY wATSON'�.�'. REVISIONS NO. DATE 1 09. 11. 2019 RESPONSE TO 1ST SITE PLAN REVIEW PLAN INFORMATION PROJECT NO. MPP -18020 FILENAME MPP18020-SITE-G1 CHECKED BY - DRAWN BY CGH SCALE 1"=40' DATE 06. 28. 2019 SHEET GRADING AND STORM DRAINAGE AREA "A" C3.01 v a DO N SEE SHEET C3.01 �s ri ri ri rT rim ri ri ri ri. ri r �17 ri ri ri ,i ri i ri ri ri r: a ri ri ri ri r� ra ri�17 ri r� ri`ri ri \ \ X i / / - i \ 1 X y 1 - -E / / ✓ j ✓� i A��� � ��y� T I L / S V Y �� ✓A -X-\ T D 1 -� \ l / �G �� ✓ �� ✓ ��% �� WI B N i V A 1 TW=354.50 � � � u �A c / v P Bw 354.00 A e 1 4 _ , 771��t�� �� T rn / \ /i�\ N % S +tv�(iv i o / / k �i �� ✓/� i BW=353.00 - �1 362:50 FEMA FUTURE 100 "\ \ \ �� �� 6W-354. YEAR 1% ANNUAL / CHANCE FLOOD ED PER SURVEY i FE0'A 25 YEAR/4% �\, - ANNUAL. CHANCE OD MAPPED PER � A � � � =362.00 SUR TOPOGRAPHY \ \/ � / /' B -361.00 _ 10' NO -BUILD � � � / > y / y5 �I�/ / SETBACK TYP. \�• i BASINIx / \ >M ✓_ i' f ` ��� =� - - 25 TL AND BUFFER L > v i �� TYPE eo VARIABLE WIDTH SCM � , AccEss AD� �. / / �BUfiLDING No- i i M4FNTENAI�CE EASEMENT / / ^ S K (TYP.) 362 / FFE=366.50 U IN - - / 20 S ACCESS AND MAINTE NCE EASEMENT _ � / � i � I - DRQ /RETAINING WALL // / � r � ( WITH FENCE 3 �� �i N (DESIGN BY OTHERS / / 62 so / / ROOF DRAINAGE / / ��� rn �� A ' 4. w TW=364.50 i BW=358.00/ TYP. A � ABL� IDTH > \ ® � � RUB EVENT CESS / / - - STORMWATFIR s4 Ta A CONTRR0L / / ✓ _ a MEASURE �"C" 10' MULTI -USE / EXPOSED BUILDING ASPHALT TRAIL / FOUNDATION o \ ��' (TYP.) / �w / / i Tito RETAINING WALL WITH FENCE 40' STREET w 366 DESIGi�BY OTHERS \; YARD ( ) _ TW- 365.00 ROOF DRAINAGE V BW=364.00 / \ (TYP.) DROP INLET / Fo \ V s68 / �i - \ (TYP.) tI ' (MJ 15'x555' AASH fO- Fo �A SIGHT DISTANCE v v (MJTRIANGLE v F° '� Q / v �� / 10'x70' SIGHT F V GHJ �+� F DISTANCE TRIANGLE / �\ �\� (TYP.) � FO�vv 4V� � F° / � � s / ARBUILDING VIAB WIDTH F° L1 ® ACCESS , \ \ EAS ENT FFE=66.25; \ �\ 4t) DROP INLET oI ' (TYP.) I' ■ \ Ab � _ \ 15'x480�AASHTO � � � � � � `P ■ \ SIGHT/DISTANCE v (MJ �� d� \ TRIANGLE _ TW-= 374.25 BW=374.75 TW=3 5.50O II Fo (4U BW�370.25 362 \ 10' NO -BUILD ' CATCH BASIN ( SETBACK \ (TYP.) (TYP.) U m �1 w 4001 STIRRUP CREEK DRIVE PIN: 0748-02-59-3645 USE: COM/WHSE-STORAGE ZONING: IL TIER: SUBURBAN BW -370.25- - � J 1 - W - J LU TW=378.50 1 Cn BW=375.00 \ 1 10' MULTI -USE \ AFo ASPHALT TRAIL (TYP.) V �I \ \ \Wo\ \° \ \ Fo ` \ TW=380.50 \ 362 1 W� BW=375.00 RETAINING WALL 6 1 3211 S MIAMI BLVD W c ( \ F° Jrn ;> WITH FENCE PIN: 0749-04-50-5259 \W\ \ (DESIGN BY OTHERS) , i USE: COM/WHSE STORAGE \ 'F0 \ ZONING: IL �' � �� TW -380.00 TIER: SUBURBAN ci\ BW=370.25 64 1 SV �I - � �����NG ��° 0g� ' \ CATCH BASIN SRM \ V-(TYP_ B� \ \ - ` \ (� rZ00- 1 P 9S �Q \ �M R�I n� � � \Fb, \ \ TW=380.00 \ 1 BW=370.25 1 -- 1 \( \ A \ TW=380.00 A \ VARIABLE WIDTH 6 �\ BW=375.00 PUBLIC�.ACCESS \ I \ (MJ v \ EASEMENT _ 1 J Fo 4p3, \ CATCH BASIN i\( \ �3jo V (TYP. Bo GRADING LEGEND ' \ o t) I \\(MJ \ F° \ 1 F° ET \ 1 I SHEETCAMA 901I \�(MJ \ \ \ YARD ' \ �(MJ \ \ i m m orm � � m, m (MJ l � � � 15'x555' AASHT � 1 �:. s \fHJ SIGHT DISTANCE \ \ 1 TRIANGLE \ \ 1 S 03 �\ \ »g■ A( TW=376..50 F° 1 S 03.02 1: M) BW=376:90 \ C_ � I I SEE SHEET C-0.01 FOR ALL PROJECT, SITE, �(41) °° \ 1 10'x' SIGHT DISTANCE ■ `v��� '�� �� � GRADING, STORM DRAINAGE AND UTILITY �r.� TRIANGLE (TYP.) NOTES \ - S24'05'49"W "■� 122.57' ALL CONSTRUCTION SHALL BE IN J GRAPHIC SCALE 0 20 40 80 ACCORDANCE WITH THE CURRENT CITY OF DURHAM ENGINEERING DESIGN AND finch -40 ft. CONSTRUCTION STANDARDS PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION 'J McADAMS The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293 www.mcadamsco.com CLIENT MERRITT PROPERTIES 2066 LORD BALTIMORE DRIVE BALTIMORE, MARYLAND 21244 'N merritt CONSTRUCTION SERVICES 2066 LORD BALTIMORE DRIVE BALTIMORE, MD 21244 PHONE 410.298.2600 FAX: 410-298.9644 www.MerrittProperties.com W 0 9:1- z_j aw X LUJ W M O rI Q zN Qa ^ z_ I..L J LU � a ''- U LU V' > O z zQ� � a V l 0 -z 0 �C a W LL 1% ``%IC N CAR , 2 REVISIONS NO. DATE 1 09. 11. 2019 RESPONSE TO 1ST SITE PLAN REVIEW PLAN INFORMATION PROJECT NO. MPP -18020 FILENAME MPP18020-SITE-G1 CHECKED BY - DRAWN BY CGH SCALE 1"=40' DATE 06. 28. 2019 SHEET GRADING AND STORM DRAINAGE AREA "B" • FLARED END SECTION STORM SERVICE LINE E E E E E WETLANDS ENDWALL SECTION RD RD RD ROOF DRAIN, 8" ADS E E E E E E NON -PERFORATED TUBING OR CATCH BASIN EQUAL 1.0% MIN. SLOPE 3' MIN. T� TREE CONSERVATION AREA COVER PVC SCHEDULE 40 IN DROP INLET TRAFFIC AREAS ■ STORM SERVICE INLET -TP-TP-TP- TREE PROTECTION FENCE NON -ENCROACHMENT LD LD LIMITS OF DISTURBANCE AREA • STORM SERVICE ROOF -DRAIN ® JUNCTION BOX WOODED AREA DRAINAGE FLOW ARROW 250 MAJOR CONTOUR ti LINE BREAK SYMBOL 252 MINOR CONTOUR 250.50 TOP & BOTTOM CURB ELEVATIONS -------250------_ EXISTING MAJOR CONTOUR 250.00 -------252------- EXISTING MINOR CONTOUR \TW=223.00 TOP OF WALL ELEVATION BW=213.00 BOTTOM OF WALL ELEVATION - - EASEMENT LINE (NOTE: BOTTOM OF WALL IS GROUND ELEVATION NOT WALL FOUNDATION) ACCESSIBLE PARKING AREA (2% MAX. SLOPE IN ALL DIRECTIONS) + 250.60 SPOT ELEVATION STORM DRAINAGE t) I \\(MJ \ F° \ 1 F° ET \ 1 I SHEETCAMA 901I \�(MJ \ \ \ YARD ' \ �(MJ \ \ i m m orm � � m, m (MJ l � � � 15'x555' AASHT � 1 �:. s \fHJ SIGHT DISTANCE \ \ 1 TRIANGLE \ \ 1 S 03 �\ \ »g■ A( TW=376..50 F° 1 S 03.02 1: M) BW=376:90 \ C_ � I I SEE SHEET C-0.01 FOR ALL PROJECT, SITE, �(41) °° \ 1 10'x' SIGHT DISTANCE ■ `v��� '�� �� � GRADING, STORM DRAINAGE AND UTILITY �r.� TRIANGLE (TYP.) NOTES \ - S24'05'49"W "■� 122.57' ALL CONSTRUCTION SHALL BE IN J GRAPHIC SCALE 0 20 40 80 ACCORDANCE WITH THE CURRENT CITY OF DURHAM ENGINEERING DESIGN AND finch -40 ft. CONSTRUCTION STANDARDS PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION 'J McADAMS The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293 www.mcadamsco.com CLIENT MERRITT PROPERTIES 2066 LORD BALTIMORE DRIVE BALTIMORE, MARYLAND 21244 'N merritt CONSTRUCTION SERVICES 2066 LORD BALTIMORE DRIVE BALTIMORE, MD 21244 PHONE 410.298.2600 FAX: 410-298.9644 www.MerrittProperties.com W 0 9:1- z_j aw X LUJ W M O rI Q zN Qa ^ z_ I..L J LU � a ''- U LU V' > O z zQ� � a V l 0 -z 0 �C a W LL 1% ``%IC N CAR , 2 REVISIONS NO. DATE 1 09. 11. 2019 RESPONSE TO 1ST SITE PLAN REVIEW PLAN INFORMATION PROJECT NO. MPP -18020 FILENAME MPP18020-SITE-G1 CHECKED BY - DRAWN BY CGH SCALE 1"=40' DATE 06. 28. 2019 SHEET GRADING AND STORM DRAINAGE AREA "B" • -\SSS o - SS — _ — �SS� — SS SS — 2917 WECK DR C — _ PIN: 0749-04-42-7006 \ SS — _ USE: VACANT INDUSTRIAL SS_ � � ZONING: IP _ S _ 15'x575' AASHTO — TIER: SUBURBAN I — SS SIGHT DISTANCE _ —WFO—SFO \ \,, _��� p,p�;� E _��� I _ SS _ 3020 S MIAMI BLVD _ PIN: 0749-04-51-3603 FO�w — USE: COM/OFFICE BLDG ���A0 V �W� ' SSS ��� ZONING: CIN FO G G FO \ W TIER: SUBURBAN a y SHTO W� �TDI�SS IGHAi7eE-G � � F10 — — — SSS GtE V G _ FO w �� — _ _ __SS _ SFO G� �F —�_�— SSS \\\ V----G�� �� y — _ FO �FO � — SFO— —� —SS \\ Fo—G� ToS�PE� FO - - — _— ss _ S70'0 „E - - S82'49'07E 7\ ���G A W—_ FO 12994 \ -_ - -89-70-- — F4 - —_---- —_ —N R - — W—w_FO �.--------- �c — U-3309&- �w Fo SS —__10 —----—� _ _ � u - __------ G_ W F _ \ ,�, EE FO G _ G --- W FO — — Fo YARD - W _ r \ 4 O — 10x70'. SIGHT F - ` — — G _ FO ss N� — TRIANGLE (T ) N 1'40" S7g, s FO F9 — �G\G — — _ — W _ Fo \ CvST'NG Ss - T I/�,• VV \ 50.63 - 09"_ - _ — }O — — FO A L E _ - - — a r0 �� FO 68 — - =\G \ q ��DE _SS ---- �` F�� _\\F� RIgg�E S' R' 2028 DR l ---z_ -- -- - - - 1A' R S78 � � �\ VV'D \493.74, E - O _ G \ - --_- R�� pUBLIC _ y W� a 01 rn A 37 �_ G.........W� W co�----- fes\ � \� FO�F01 \�__� ACIM G �w PERMANENT SLOPE EASEMENT T o I I I (TYP,) 35 _ ------ —W NC DOT PROJECT #U-33098 Ss t p A �� F6 _ G �FO I r W CATCH BASIN O F x70' SI STANCE — G— `—� w \ yo I use I 372 �0 TRIAN�C--(ZYP.) -� — �� GAG w e-3 / — G W - - �A_—W CO I_ - - 370 - — — — _ _ W� w y y° - -- YARD "36'4-- - F FO — - G o / I _ _ FO S (77m Lie I I CATCH BASIN ROOF DRAINAGE / VARIABLE WIDTH PERMANENT (TYP.) / PUBLIC ACCESS / DRNNAGE EASEMENT I I 30' SANITARY SEWER I (TYP.) / \ / > BASEMENT / rr rr /B 2 INFORMATION OFOUN RECORDATION - — — 50' RIPARIAN BUFFER ( �� ��� 3354, PG. 70 SEMENT ( o (MEASURED 50' FROM TOP 36 OF BANK, EACH SIDE) 364 �- . 10' MULTI -USE % ASPHALT TRAIL TYP.) TI I I v v A �� ACCESSANDf H SCM 10' NO -BUILD �� n ��� /� IIVARIABLE \MAINTENANCE EASEMENT 10' NO SETBACK TYP. o 362 �I � /'' / o ® SETBAC D)� SCJ a -- 372 � � � � I \ I J JURISDICTIONAL i �d —ai/dl—al/dl� ai/dl —� 4 \ I, STORM ATER I WETLAND BUFFER TYP. �I I CONTRO I ( ) �—� \ I MEASURE A I �/ — — \ 7� -> \ �� �� �� v \ v > ' \ �A �- i - i /`\ ������ ��� - , `, A / - , �_ �� - �� , _ �� ? '4° 15'x480' AASHTO —� �� _ i SIGHT DISTANCE `�, V '� \ �\ FEMA 100 YEAR/1% I l�il / �`��� �� �` ✓ _ �k i X_ / i� Y f„X\/`' ° / X / TRIANGLE / % I \ ANNUAL CHANCE I l A V ���'i��-! { \ A/ V > I FLOOD MAPPED PER \�� / / / v l SURVEY TOPOGRAP may, � �,v A yice / �1 � �' � � � �/ / '��-� �i��l ��l `�\ ' � A, '� `� � �� YAi �RD ,7 v��— / a / / / o � <v �� � V � V � X / �l/Y�/ A �%- �� A �� l ���AN �1 / M — �- TYP.) \ /���\ %X \ 1 - / \S /fie// % \x'—c / \ o L // �' 3123 S MIAMI BLVD / 1 o / PIN: 0749-04-50-4965 / ♦ S / LD TP LD \ vy < i ��' / �- G , ��� / P �— / TP/LD TP/LD TP/LD — LD TP LD 1 O N CS U LD \ F // Al� � i � � E TP LD � —� � � ETA \ U ��V 2 � �� � v. .- � 1 \ i � � � � A \ � \ \ \ i / TP LD— / � S � ACK � USE: RES/1-FAMILY y V �� \ \ , /� ( �� ZONING: IL �X \ n ' v Iia / / % TYP. / - - o v v / \/4//_ � }� �y� _-� � / / � � � �d TIER: SUBURBAN _ � A ��,v� \ ' � �� �\ tii�ir.�Glriyr��ii�� ��.��'�►i.r.`� � = ---�--------=------=------��--�-------= -- — —1--- --- --- — -- —=4���=---/ � �-----=---- GRADING LEGEND SEE SHEET C3.02 FLARED END SECTION STORM SERVICE LINE E E E E E WETLANDS E E E E E E ENDWALL SECTION RD RD RD ROOF DRAIN, 8" ADS L -^-- -J NON -PERFORATED TUBING OR EQUAL 1.0% MIN. SLOPE 3' MIN. I SHELr � CATCH BASIN TREE CONSERVATION AREA COVER PVC SCHEDULE 40 IN ' DROP INLET TRAFFIC AREAS ' J ■ STORM SERVICE INLET TPTPTP TREE PROTECTION FENCE UNMAPPED NON -ENCROACHMENT L m LD LD AREA LIMITS OF DISTURBANCE � _ � `=- n � • STORM SERVICE ROOF -DRAIN \ ' � � GRAPHIC SCALE JUNCTION BOX WOODED AREA \ S:02 o zo 40 so J JOR CONTOUR 1 inch = 40 ft. �--- DRAINAGE FLOW ARROW 250 MANOR CONTOUR ti LINE BREAK SYMBOL 252 250.00 TOP & BOTTOM CURB ELEVATIONS - --250- -- EXISTING MAJOR CONTOUR \ \ \ \ ,, SEE SHEET C0.01 FOR ALL PROJECT, SITE, _______------- EXISTING MINOR CONTOUR \Tw-223.00 TOP OF WALL ELEVATION \ � GRADING, STORM DRAINAGE AND UTILITY BW=213.00 BOTTOM OF WALL ELEVATION — — EASEMENT LINE ��� NOTES (NOTE: BOTTOM OF WALL IS GROUND ALL CONSTRUCTION SHALL BE IN ELEVATION NOT WALL FOUNDATION) ACCESSIBLE PARKING AREA + 250.60 SPOT ELEVATION (2% MAX. SLOPE IN ALL DIRECTIONS) ACCORDANCE WITH THE CURRENT CITY OF DURHAM ENGINEERING DESIGN AND STORM DRAINAGE CONSTRUCTION STANDARDS PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION 'J McADAMS The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293 www.mcadamsco.com CLIENT MERRITT PROPERTIES 2066 LORD BALTIMORE DRIVE BALTIMORE, MARYLAND 21244 merritt CONSTRUCTION SERVICES 2066 LORD BALTIMORE DRIVE BALTIMORE, MD 21244 PHONE 410.298.2600 FAX: 410-298.9644 www.MerrittProperties.com W 0 9:1- z Q w X LUJ W M 1 0 Q zN Qa z � J � w � � a U � � 2 LU o � z z< � a J � z 0 �C a W LL ;,►wA ; S0-,', ��. REVISIONS C NO. DATE 1 09. 11. 2019 RESPONSE TO 1ST SITE PLAN REVIEW PLAN INFORMATION PROJECT NO. MPP -18020 FILENAME MPP18020-SITE-G1 CHECKED BY - DRAWN BY CGH SCALE 1"=40' DATE 06. 28. 2019 SHEET GRADING AND STORM DRAINAGE AREA "C' C3.03 Flex Buildings - TW Alexander Photo 1: Open Water Area A from lower end looking upstream (9/4/19) Wetland H(+/- 0.044 AC ) Wetland J(+/- 0.016 AC ) Wetland F(+/- 0.129 AC ) Wetland D(+/- 0.035 AC ) Wetland C(+/- 0.002 AC ) Wetland B(+/- 0.010 AC ) Wetland A(+/- 0.001 AC ) End Stream A(continues off site) Start Stream C(+/- 165 LF) End Stream Cat Stream A End Stream Bat Stream A Start Stream B4(+/- 292 LF) Stop Stream B Stop Stream B Start Stream B3(+/- 366 LF) Start Stream B2(+/- 34 LF) Stop Stream B Start Stream B1at culvert(+/- 876 LF) Start Stream A2(+/- 1,154 LF) Stop Stream A Start Stream A1 at culvert(+/- 836 LF) Open Water A(+/- 0.275 AC ) Wetland E(+/- 8.276 AC ) Wetland G(+/- 0.798 AC ) 0 200100Feet1 inch = 200 feet $ LEGEND Stream 2-ft contours Ju risd ictio nal w etlan d 50-ft rip arian buffer Open water Proje ct Area FIGURE 4. VERIFIED PRELIMINARY JURISDICATIONAL DETERMINATION MAPFLEX BUILDINGS - TW ALEXANDERDURHAM, DURHAM COUNTY, NORTH CAROLINA(Verified by Ross Sullivan, USACE on May 1, 2019) X:\Projects\MPP\MPP-18020\Storm\Wetlands\GIS\MPP18020_Figure 4 PJD Map.mxd, 8/20/2019 11:51:11 AM, roth 8/20/2019 rothMPP-18020DATE:JOB NO:DRAWN BY: 3VERSION: 0 200100Feet1 inch = 200 feet $ LEGEN D Project area Existing stream Existing wetland Neuse buffer Wetland buffer Existing sanitary sew er Existing sanitary sewer easement Existing Duke Power right of way Existing 2-ft contours Proposed building Proposed water line Proposed pavement Proposed pond Proposed riprap Proposed storm drain Proposed sanitary sewer line Proposed wall Proposed trail Proposed limits of disturbance Proposed 2-ft contours FIGURE 5. OVERALL IMPACTS MAPFLEX BUILDINGS - TW ALEXANDERDURHAM, DURHAM COUNTY, NORTH CAROLINA X:\Projects\MPP\MPP-18020\Storm\Wetlands\GIS\MPP18020_Figure 5 Overall Impacts Map-1.mxd, 10/2/2019 4:05:55 PM, roth 10/2/2019 rothMPP-18020DATE:JOB NO:DRAWN BY: 3VERSION: Proposed Impacts Permanent stream im pact Permanent wetland impact Temporary wetland im pact Neuse buffer impacts Zone 1 Zone 2 INSET 1 INSET 2 INSET 3 INSET 4 0 3015Feet1 inch = 30 feet $ LEGEND Project area Existing stream Existing wetland Neuse buffer Wetland buffer Existing sanitary sewer Existing sanitary sewer easement Existing Duke Power right of way Existing 2-ft contours Proposed building Proposed water line Proposed pavement Proposed pond Proposed riprap Proposed storm drain Proposed sanitary sewer line Proposed wall Proposed trail Proposed limits of disturbance Proposed 2-ft contours FIGURE 5 - INSET 1FLEX BUILDINGS - TW ALEXANDERDURHAM, DURHAM COUNTY, NC 10/2/2019 rothMPP-18020DATE:JOB NO:DRAWN BY: X:\Projects\MPP\MPP-18020\Storm\Wetlands\GIS\MPP18020_Figure 5-Inset 1.mxd, 10/2/2019 3:47:37 PM, roth Proposed permanent stream impact - S1+/- 70 LF (212 SF) 1VERSION: Limits of disturbance Proposed Impacts Permanent stream impact Neuse buffer impacts Zone 1 Zone 2 Proposed 36" concrete box culvert Zone 1 - 30' Zone 2 - 20' Neuse buffer Proposed Neuse Zone 1buffer impact - B1+/- 4,579 SF Proposed Neuse Zone 2buffer impact - B1+/- 3,148 SF Stream BIntermittent 0 3015Feet1 inch = 30 feet $ LEGEND Project area Existing stream Existing wetland Neuse buffer Wetland buffer Existing sanitary sewer Existing sanitary sewer easement Existing Duke Power right of way Existing 2-ft contours Proposed building Proposed water line Proposed pavement Proposed pond Proposed riprap Proposed storm drain Proposed sanitary sewer line Proposed wall Proposed trail Proposed limits of disturbance Proposed 2-ft contours FIGURE 5 - INSET 2FLEX BUILDINGS - TW ALEXANDERDURHAM, DURHAM COUNTY, NC 10/2/2019 rothMPP-18020DATE:JOB NO:DRAWN BY: X:\Projects\MPP\MPP-18020\Storm\Wetlands\GIS\MPP18020_Figure 5-Inset 2.mxd, 10/2/2019 3:51:06 PM, roth Proposed temporarywetland impact - W1+/- 0.011 ac. 1VERSION: Limits of disturbance Proposed Impacts Temporary wetland impact Property boundary 0 3015Feet1 inch = 30 feet $ LEGEND Project area Existing stream Existing wetland Neuse buffer Wetland buffer Existing sanitary sewer Existing sanitary sewer easement Existing Duke Power right of way Existing 2-ft contours Proposed building Proposed water line Proposed pavement Proposed pond Proposed riprap Proposed storm drain Proposed sanitary sewer line Proposed wall Proposed trail Proposed limits of disturbance Proposed 2-ft contours FIGURE 5 - INSET 3FLEX BUILDINGS - TW ALEXANDERDURHAM, DURHAM COUNTY, NC 10/2/2019 rothMPP-18020DATE:JOB NO:DRAWN BY: X:\Projects\MPP\MPP-18020\Storm\Wetlands\GIS\MPP18020_Figure 5-Inset 3.mxd, 10/2/2019 4:05:26 PM, roth Proposed permanentwetland impact - W2+/- 0.084 ac. 1VERSION: Limits of disturbance Proposed Impacts Permanent wetland impact Neuse buffer impacts Zone 1 Zone 2 Zone 1 - 30'Zone 2 - 20' Proposed Neuse Zone 1buffer impact - B2+/- 546 SF Proposed Neuse Zone 2buffer impact - B2+/- 609 SF Stream APerennial Proposed sanitary sewer line Existing sanitary sewer line Neuse buffer 0 3015Feet1 inch = 30 feet $ LEGEND Project area Existing stream Existing wetland Neuse buffer Wetland buffer Existing sanitary sewer Existing sanitary sewer easement Existing Duke Power right of way Existing 2-ft contours Proposed building Proposed water line Proposed pavement Proposed pond Proposed riprap Proposed storm drain Proposed sanitary sewer line Proposed wall Proposed trail Proposed limits of disturbance Proposed 2-ft contours FIGURE 5 - INSET 4FLEX BUILDINGS - TW ALEXANDERDURHAM, DURHAM COUNTY, NC 10/2/2019 rothMPP-18020DATE:JOB NO:DRAWN BY: X:\Projects\MPP\MPP-18020\Storm\Wetlands\GIS\MPP18020_Figure 5-Inset 4.mxd, 10/2/2019 3:58:25 PM, roth Proposed permanentwetland impact - W3+/- 0.003 ac. 1VERSION: Limits of disturbance Proposed Impacts Permanent wetland impact Zone 1 - 30'Zone 2 - 20' Neuse buffer Proposed sanitarysewer line North Carolina Department of Natural and Cultural Resources State Historic Preservation Office Ramona M. Bartos, Administrator Governor Roy Cooper Office of Archives and History Secretary Susi H. Hamilton Deputy Secretary Kevin Cherry Location: 109 East Jones Street, Raleigh NC 27601 Mailing Address: 4617 Mail Service Center, Raleigh NC 27699-4617 Telephone/Fax: (919) 807-6570/807-6599 August 20, 2019 Kelly Roth McAdams 2905 Meridian Parkway Durham, NC 27713 Re: Construct Flex Buildings, TW Alexander Drive & South Miami Boulevard, Research Triangle Park, Durham, Durham County, ER 19-2296 Dear Ms. Roth: Thank you for your letter of July 16, 2019, concerning the above project. We have conducted a review of the project and are aware of no historic resources which would be affected by the project. Therefore, we have no comment on the project as proposed. The above comments are made pursuant to Section 106 of the National Historic Preservation Act and the Advisory Council on Historic Preservation’s Regulations for Compliance with Section 106 codified at 36 CFR Part 800. Thank you for your cooperation and consideration. If you have questions concerning the above comment, contact Renee Gledhill-Earley, environmental review coordinator, at 919-807-6579 or environmental.review@ncdcr.gov. In all future communication concerning this project, please cite the above referenced tracking number. Sincerely, Ramona Bartos, Deputy State Historic Preservation Officer