Loading...
HomeMy WebLinkAboutNC0004774_Inspection_20190925United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN I 2 IF I 3 I NC0004774 111 12 I 19/09/25 I17 18 i R i 19 i G i 201 I 211111 I I I I I I II I I I I I I I I I I I I I I I I I I I I I I I II I I I I I f6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA ---------------------- Reserved ------------------- 671 70I�_71 I 72 r 73I i74 751 I I I I 80 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES oermit Number) 10:OOAM 19/09/25 18/11/01 Buck Steam Station 1555 Dukeville Rd Exit Time/Date Permit Expiration Date Salisbury NC 28146 11:42AM 19/09/25 23/10/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data Dale Wooten/ORC/704-630-3086/ Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Bristol Grohol, /Engineer 1/980-373-2693/ No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Other Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(sa of Inspector(s) Agency/Office/Phone and Fax Numbers Date ocuSigned by: Roberto Scheller S� DWR/MRO WQ/252-946-6481/ 91C2A007838943E... 10/8/2019 Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date W. Corey Basinger DWR/Division of Water Quality/704-235-2194/ EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# NPDES yr/mo/day Inspection Type (Cont.) NC0004774 I11 121 19/09/25 117 18 1 RI Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) On September 25, 2019 Roberto Scheller of the Mooresville Regional Office conducted a reconnaissance inspection of decanting from Cell #3 and discharge via outfall #007. At the time of inspection filter equipment was not in operation and not discharging via outfall #007. Outfalls 002A and 002 have been removed and no longer discharge. Outfall #007 reviewed and not discharging at time of inspection. Outfall #006 reviewed and not discharging at time of inspection. Please note that in accordance with your NPDES Permit (NC0004774) Part I, B(4.),(Outfall 007 - Ash Pond Dewatering), Footnotes: 4. "The Permittee shall continuously monitor TSS consenteration when the dewatering process commences (and one or more pumps is operating), and the dewatering pump(s) shall be shut off automaticlly when the 15-minute running average TSS exceeds one half the Daily Maximum TSS limit." Page# Permit: NC0004774 Inspection Date: 09/25/2019 Other Comment: Owner - Facility: Buck Steam Station Inspection Type: Reconnaissance Yes No NA NE Page#