Loading...
HomeMy WebLinkAbout1910_Brickhaven_RiverbendPCBSampleResults_March2017_DIN27753_20170309#=CL# March 09, 2017 LIMS USE: FR Prelim - PROGRAM LIMS OBJECT ID: 92332076 92332076 Project: Pace Project No.: RE: Program Manager Duke Energy 13339 Hagers Ferry Road Bldg. 7405 MG30A2 Huntersville, NC 28078 J17030104 Dear Program Manager: Enclosed are the analytical results for sample(s) received by the laboratory on March 03, 2017. The results relate only to the samples included in this report. Results reported herein conform to the most current, applicable TNI/NELAC standards and the laboratory's Quality Assurance Manual, where applicable, unless otherwise noted in the body of the report. If you have any questions concerning this report, please feel free to contact me. Sincerely, Tyriek Hooks for kevin.herring@pacelabs.com HORIZON Database Administrator Kevin Herring 1(704)875-9092 Enclosures cc:Program Manager, Duke Energy REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Page 1 of 11 Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 #=CP# CERTIFICATIONS Pace Project No.: Project: 92332076 J17030104 Charlotte Certification IDs 9800 Kincey Ave. Ste 100, Huntersville, NC 28078 North Carolina Drinking Water Certification #: 37706 North Carolina Field Services Certification #: 5342 North Carolina Wastewater Certification #: 12 South Carolina Certification #: 99006001 Florida/NELAP Certification #: E87627 Kentucky UST Certification #: 84 Virginia/VELAP Certification #: 460221 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Page 2 of 11 Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 #=SS# SAMPLE SUMMARY Pace Project No.: Project: 92332076 J17030104 Lab ID Sample ID Matrix Date Collected Date Received 92332076001 2017007194 Solid 03/03/17 09:30 03/03/17 13:20 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Page 3 of 11 Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 #=SA# SAMPLE ANALYTE COUNT Pace Project No.: Project: 92332076 J17030104 Lab ID Sample ID Method Analytes Reported LaboratoryAnalysts 92332076001 2017007194 EPA 8082 8 PASI-CHSK ASTM D2974-87 1 PASI-CCLW REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Page 4 of 11 Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 #=HO# SUMMARY OF DETECTION Pace Project No.: Project: 92332076 J17030104 Parameters AnalyzedResult Lab Sample ID Report Limit QualifiersUnitsMethod Client Sample ID 92332076001 2017007194 PCB-1260 (Aroclor 1260)0.48 mg/kg 03/07/17 09:550.045EPA 8082 Percent Moisture 26.4 %03/06/17 09:310.10ASTM D2974-87 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Page 5 of 11 Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 #=NA# PROJECT NARRATIVE Pace Project No.: Project: 92332076 J17030104 Method: Client:Duke Energy EPA 8082 Date:March 09, 2017 Description:8082 GCS PCB General Information: 1 sample was analyzed for EPA 8082. All samples were received in acceptable condition with any exceptions noted below or on the chain-of custody and/or the sample condition upon receipt form (SCUR) attached at the end of this report. Hold Time: The samples were analyzed within the method required hold times with any exceptions noted below. Sample Preparation: The samples were prepared in accordance with EPA 3546 with any exceptions noted below. Initial Calibrations (including MS Tune as applicable): All criteria were within method requirements with any exceptions noted below. Continuing Calibration: All criteria were within method requirements with any exceptions noted below. Surrogates: All surrogates were within QC limits with any exceptions noted below. Method Blank: All analytes were below the report limit in the method blank, where applicable, with any exceptions noted below. Laboratory Control Spike: All laboratory control spike compounds were within QC limits with any exceptions noted below. Matrix Spikes: All percent recoveries and relative percent differences (RPDs) were within acceptance criteria with any exceptions noted below. Additional Comments: This data package has been reviewed for quality and completeness and is approved for release. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Page 6 of 11 Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92332076 J17030104 Sample:2017007194 Lab ID:92332076001 Collected:03/03/17 09:30 Received:03/03/17 13:20 Matrix:Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units DF Prepared Analyzed CAS No.QualReport Limit Analytical Method: EPA 8082 Preparation Method: EPA 35468082 GCS PCB PCB-1016 (Aroclor 1016)ND mg/kg 03/07/17 09:55 12674-11-203/06/17 14:300.045 1 PCB-1221 (Aroclor 1221)ND mg/kg 03/07/17 09:55 11104-28-203/06/17 14:300.045 1 PCB-1232 (Aroclor 1232)ND mg/kg 03/07/17 09:55 11141-16-503/06/17 14:300.045 1 PCB-1242 (Aroclor 1242)ND mg/kg 03/07/17 09:55 53469-21-903/06/17 14:300.045 1 PCB-1248 (Aroclor 1248)ND mg/kg 03/07/17 09:55 12672-29-603/06/17 14:300.045 1 PCB-1254 (Aroclor 1254)ND mg/kg 03/07/17 09:55 11097-69-103/06/17 14:300.045 1 PCB-1260 (Aroclor 1260)0.48 mg/kg 03/07/17 09:55 11096-82-503/06/17 14:300.045 1 Surrogates Decachlorobiphenyl (S)64 %03/07/17 09:55 2051-24-303/06/17 14:3021-132 1 Analytical Method: ASTM D2974-87Percent Moisture Percent Moisture 26.4 %03/06/17 09:310.10 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 03/09/2017 11:43 AM Page 7 of 11 Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92332076 J17030104 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 350983 EPA 3546 EPA 8082 8082 GCS PCB Associated Lab Samples:92332076001 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:1946904 Associated Lab Samples:92332076001 Matrix:Solid Analyzed PCB-1016 (Aroclor 1016)mg/kg ND 0.033 03/07/17 10:16 PCB-1221 (Aroclor 1221)mg/kg ND 0.033 03/07/17 10:16 PCB-1232 (Aroclor 1232)mg/kg ND 0.033 03/07/17 10:16 PCB-1242 (Aroclor 1242)mg/kg ND 0.033 03/07/17 10:16 PCB-1248 (Aroclor 1248)mg/kg ND 0.033 03/07/17 10:16 PCB-1254 (Aroclor 1254)mg/kg ND 0.033 03/07/17 10:16 PCB-1260 (Aroclor 1260)mg/kg ND 0.033 03/07/17 10:16 Decachlorobiphenyl (S)%85 21-132 03/07/17 10:16 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 1946905LABORATORY CONTROL SAMPLE & LCSD: LCSSpike LCSD % Rec RPD Max RPD LCSD Result 1946906 PCB-1016 (Aroclor 1016)mg/kg 0.096.17 57 31-120670.11 15 30 PCB-1260 (Aroclor 1260)mg/kg 0.14.17 81 32-120790.13 3 30 Decachlorobiphenyl (S)%92 21-13285 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 03/09/2017 11:43 AM Page 8 of 11 Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92332076 J17030104 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 350779 ASTM D2974-87 ASTM D2974-87 Dry Weight/Percent Moisture Associated Lab Samples:92332076001 Parameter Units Dup Result Max RPD QualifiersRPDResult 92331866001 1945901SAMPLE DUPLICATE: Percent Moisture %34.7 R1272545.3 Parameter Units Dup Result Max RPD QualifiersRPDResult 92332076001 1945902SAMPLE DUPLICATE: Percent Moisture %26.1 1 2526.4 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 03/09/2017 11:43 AM Page 9 of 11 Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 #=QL# QUALIFIERS Pace Project No.: Project: 92332076 J17030104 DEFINITIONS DF - Dilution Factor, if reported, represents the factor applied to the reported data due to dilution of the sample aliquot. ND - Not Detected at or above adjusted reporting limit. J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit. MDL - Adjusted Method Detection Limit. PQL - Practical Quantitation Limit. RL - Reporting Limit. S - Surrogate 1,2-Diphenylhydrazine decomposes to and cannot be separated from Azobenzene using Method 8270. The result for each analyte is a combined concentration. Consistent with EPA guidelines, unrounded data are displayed and have been used to calculate % recovery and RPD values. LCS(D) - Laboratory Control Sample (Duplicate) MS(D) - Matrix Spike (Duplicate) DUP - Sample Duplicate RPD - Relative Percent Difference NC - Not Calculable. SG - Silica Gel - Clean-Up U - Indicates the compound was analyzed for, but not detected. Acid preservation may not be appropriate for 2 Chloroethylvinyl ether. A separate vial preserved to a pH of 4-5 is recommended in SW846 Chapter 4 for the analysis of Acrolein and Acrylonitrile by EPA Method 8260. N-Nitrosodiphenylamine decomposes and cannot be separated from Diphenylamine using Method 8270. The result reported for each analyte is a combined concentration. Pace Analytical is TNI accredited. Contact your Pace PM for the current list of accredited analytes. TNI - The NELAC Institute. LABORATORIES Pace Analytical Services - CharlottePASI-C ANALYTE QUALIFIERS RPD value was outside control limits.R1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 03/09/2017 11:43 AM Page 10 of 11 Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 #=CR# QUALITY CONTROL DATA CROSS REFERENCE TABLE Pace Project No.: Project: 92332076 J17030104 Lab ID Sample ID QC Batch Method QC Batch Analytical Method Analytical Batch 92332076001 350983 3510842017007194EPA 3546 EPA 8082 92332076001 3507792017007194ASTM D2974-87 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 03/09/2017 11:43 AM Page 11 of 11 Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092