Loading...
HomeMy WebLinkAbout2803-DareCoCDLF_PhaseV_CQARpt_DIN27182_20161220D a r e C o u n t y C & D L a n d f i l l F a c i l i t y P e r m i t N o . 2 8 0 3 - C D L F - 1 9 9 5 P h a s e V E x p a n s i o n C o n s t r u c t i o n Q u a l i t y A s s u r a n c e R e p o r t D e c e m b e r 2 0 1 6 i Table of Contents Section 1 Introduction Section 2 Earthwork 2.1 General ............................................................................................................................................................... 2-1 2.2 Site Preparation .............................................................................................................................................. 2-1 2.2.1 Overview ............................................................................................................................................... 2-1 2.2.2 Clearing, Grubbing, and Organic Material Removal ........................................................... 2-1 2.2.3 Undercutting and Backfilling ....................................................................................................... 2-1 2.3 Filling/Embankment Construction ........................................................................................................ 2-2 2.3.1 Fill Materials ........................................................................................................................................ 2-2 2.3.2 Fill Placement and Testing ............................................................................................................ 2-2 Section 3 Record Drawings Section 4 Hydrogeologic Conditions Appendices Appendix A – Geotechnical Reports Appendix B – As-Built Topographic Survey Appendix C – Contractor Activity Reports List of Figures Figure 2-1 Site Map .............................................................................................................................................. 2-5 Table of Contents ii This Page intentionally left blank. 1-1 Section 1 Introduction The Dare County facility is located off of US-264 in Manns Harbor, Dare County, North Carolina. A Permit to Construct (Permit No. 2803-CDLF-1995) was issued by the North Carolina Department of Environmental Quality (NCDEQ), formerly the NCDENR, Solid Waste Section on August 28, 2015 for the Phase V expansion of the Construction and Demolition Debris (C&D) Landfill. The Phase V area, approximately 2 acres, is located between closed Cell 1 and closed Cell 2 and will be an in-fill between the two closed cells. A pre-construction meeting was held on June 2, 2016 with the County, CDM Smith, and RPC, Inc. staff to discuss the construction activities, field engineering and testing, communications, and as-built drawings. The construction of Phase V was completed in approximately ten weeks. Construction activities began on June 20, 2016 and substantial completion was reached on September 8, 2016. This report summarizes Construction Quality Assurance (CQA) services performed during the construction of the expansion area and provides complete CQA documentation for the Dare County C&D Landfill – Phase V Expansion project. This report contains field reports, in-place field density test results, conformance test results, and discussions of the test results and procedures used during Phase V construction, which can be broken down into the following critical element: Landfill foundation/subgrade preparation. Phase V was constructed in accordance with North Carolina Solid Waste Rules, Rules 15A NCAC 13B.0540 and .0541; and the approved Dare County C&D Landfill Substantial Amendment and Phase V Permit to Construct Application dated May 2015. The components of Phase V addressed within this report are as follows: Section 2 – Earthwork (all earthwork performed associated with the Phase V area) Section 3 – Record Drawings Section 4 – Hydrogeologic Conditions Documentation compiled throughout the construction of the landfill, which append the above sections, is provided in Appendices A through C of this report as outlined below: Appendix A – QC and QA Geotechnical Laboratory Reports Appendix B – Record Drawings Appendix C – Contractor Activity Reports The parties involved in the construction, testing, and construction observation services and their respective roles are summarized in the following table. Section 1 • Introduction 1-2 Party Role Dare County (County) Owner RPC Contracting, Inc. Contractor hired by the County to perform the construction work. GET Solutions, Inc. QC Inspection and testing. Retained by construction Contractor. Quible & Associates, P.C. Surveyor hired by the Contractor to provide project layout and control services, and prepare record drawings. CDM Smith Inc. (CDM Smith) Engineering consultant – provided general services during construction such as clarification of design and construction issues and coordination and review of CQA testing. ECS Carolinas, LLC. CQA Independent testing laboratory – retained by CDM Smith to conduct final CQA testing of base pad. Geotechnics Independent geotechnical testing laboratory – retained by CDM Smith to complete initial testing of borrow material. 2-1 Section 2 Earthwork 2.1 General General Contractor, RPC Contracting, Inc. (Contractor) performed all aspects of landfill construction. GET Solutions, Inc. (GET) was retained by the Contractor to provide QC testing during construction of the base pad for the project. Earthwork conducted for the Phase V construction included those work activities required to provide a stable foundation for the approximately 2-acre Phase V waste disposal area including over- excavation and backfill to grade of the ditch area, construction of the 5-ft thick base pad, and completion of the access road to the Phase V pad. The total construction area including all the features listed was approximately 2 acres. Construction activities consisted of site preparation, over excavation, fill placement, and access road construction. QC observation and field testing were performed during earthwork activities by GET to document conformance with the project specifications. Copies of GET’s Inspection and Testing Reports are contained in Appendix A. This report contains laboratory test data for the conformance testing of the borrow materials, QC observations during base pad installation, and in-place density testing results. In addition, Appendix A also includes QA geotechnical data from the initial borrow source material and final in-place density testing of the base pad. Based on observations, testing, and review of the certified subgrade elevation surveys provided by Quible & Associates, the Phase V compacted base pad and other related earthwork activities as noted above have been completed in general accordance with the Permit to Construct and the plans and specifications. 2.2 Site Preparation 2.2.1 Overview Preparation of the site consisted of clearing and grubbing, removal of topsoil and other organic materials, soil excavation, proof-rolling, undercutting unsuitable material and backfilling undercut areas, base pad construction, and access road construction. CQA testing and observation was performed by GET in consultation with the CDM Smith Project Engineer during Phase V construction. 2.2.2 Clearing, Grubbing, and Organic Material Removal The clearing, grubbing, and removal of topsoil and other organic materials prior to subgrade preparation and fill placement was performed by the Contractor to assure that the soil surfaces were generally free of organic matter and other objectionable materials. A GET representative and CDM Smith representative examined the exposed soil subgrade prior to placement of any fill. 2.2.3 Undercutting and Backfilling Subgrade materials in the ditch area were soft and some undercutting was required. The ditch area was undercut to an average depth of 2 feet below grade and backfilled with compacted common fill material. Section 2 • Earthwork 2-2 2.3 Filling/Base Pad Construction 2.3.1 Fill Materials The Phase V base pad construction and backfill to achieve completed pad elevations including backfill of undercut areas required approximately 16,945 cy of fill materials. The fill materials were obtained from the County’s existing on-site borrow pit located west of the existing C&D landfill area as shown on Figure 2-1. Prior to construction, two samples of the potential fill soils were tested for moisture content (ASMT D2216), sieve analyses (ASTM D6913), Atterberg limits determinations (ASTM D4318), moisture-density compaction tests (ASTM D698), and internal friction angle (ASTM D4767). Initial tests were conducted by Geotechnics. The results of these conformance laboratory tests indicated that the materials generally consisted of sandy silt and clay met the specification requirements for common fill. The laboratory test results are included in Appendix A. 2.3.2 Fill Placement and Testing The specification requirements for fill placement below and surrounding the landfill cell area were as follows: In-Place Density – compacted to a minimum of 95% of the maximum dry density of the soil as determined in accordance with ASTM D698. Moisture Content – within five percent of the optimum moisture content as determined in accordance with ASTM D698. Loose Lift Thickness – eight inches maximum. Internal Friction Angle – minimum of 28 degrees. Fill placement was observed by a GET technician. The fill soils were checked to verify the absence of topsoil, roots, and other deleterious materials. Lift thicknesses were monitored to verify that adequate compaction was achieved. A 2-foot bridge lift was permitted in the base of the over-excavated area of the ditch, after which, 8-inch lifts were utilized. The GET technician performed in-place field density tests to evaluate the compaction (percent of maximum dry density) of the fill soils. Dry density was determined using a nuclear density gauge (ASTM D6938). In-place field density tests were generally performed on average of every 5,000 cubic yard, as required by the CQA plan. GET performed a total of 32 compaction tests during the placement of fill material. If the test results indicated in-place density of the fill was less than the required minimum percentage of maximum dry density as determined by ASTM D698, the lift of fill was re-worked, and then re-tested. Re-working the fill consisted of performing additional passes with the sheepsfoot vibratory compactor or moisture conditioning the soil prior to compaction. The results of the in-place field density tests are included in the reports included in Appendix A. All QC testing indicated that compaction of greater than 95% was achieved. Following completion of the base pad, additional QA testing for compaction was completed by ECS Carolinas, LLC (ECS). The ECS technician performed in-place field density tests to evaluate the compaction (percent of maximum dry density) of the final pad elevation. Dry density was determined using a nuclear density gauge (ASTM D6938). Section 2 • Earthwork 2-3 ECS performed a total of 10 compaction tests of the final pad lift. If the test results indicated in-place density of the fill was less than the required minimum percentage of maximum dry density as determined by ASTM D698, the area was re-work and re-tested. All final QA results were greater than 95% compaction. Section 2 • Earthwork 2-4 This Page intentionally left blank. Section 2 • Earthwork 2-6 This Page intentionally left blank. 3-1 Section 3 Record Drawings The Contractor retained Quible & Associates, Inc. (Quible) to perform surveying services during the Phase V landfill expansion construction. Quible provided the following services: earthwork grading stakes, control points, temporary benchmarks, and an as-built topographic survey. Quible was also on-site during different stages of work to provide direction regarding the construction limits and elevations of the earthwork in accordance with the approved permit drawings. The as-built topographic survey provides a record of the completed construction of the Phase V landfill expansion disposal area. The as-built survey provides information regarding the elevation and limits of the Phase V landfill expansion footprint and access road. CDM Smith has reviewed the as-built topographic survey and found the completed construction work to be generally in accordance with the approved Permit to Construct drawings. The as-built survey has been certified by a professional land surveyor currently licensed in the State of North Carolina. The certified survey is included in Appendix B. Section 3 • Record Drawings 3-2 This Page intentionally left blank. 4-1 Section 4 Hydrogeologic Conditions On July 19, 2016, a CDM Smith geotechnical engineer was onsite to inspect the subgrade conditions of the Phase V expansion. The inspection determined that conditions were consistent with observations made during the previous Design Hydrogeologic Investigation and the information presented in the Design Hydrogeologic Report. No pertinent geologic features were encountered within the landfill footprint that would impact groundwater flow or separation requirements. There are no additional groundwater or landfill gas monitoring wells associated with this phase and all piezometers in this area were abandoned during previous investigations. Appendix A QC and QA Data QA Geotechnical Lab Borrow Area Results 2200 Westinghouse Blvd., Suite 103 • Raleigh, NC 27604 • Phone (919) 876-0405 • Fax (919) 876-0460 • www.geotechnics.net DCN: Data Transmittal Letter Date: 1/28/05 Rev.: 1 December 17, 2015 Project No. 2015-775-001 Mr. Mat Colone CDM Smith, Inc. 5400 Glenwood Ave., Suite 300 Raleigh, NC 27612 colonemf@cdmsmith.com Transmittal Laboratory Test Results Dare County C&D Landfill Please find attached the laboratory test results for the above referenced project. The tests were outlined on the Project Verification Form that was transmitted to your firm prior to the testing. The testing was performed in general accordance with the methods listed on the enclosed data sheets. The test results are believed to be representative of the samples that were submitted for testing and are indicative only of the specimens which were evaluated. We have no direct knowledge of the origin of the samples and imply no position with regard to the nature of the test results, i.e. pass/fail and no claims as to the suitability of the material for its intended use. The test data and all associated project information provided shall be held in strict confidence and disclosed to other parties only with authorization by our Client. The test data submitted herein is considered integral with this report and is not to be reproduced except in whole and only with the authorization of the Client and Geotechnics. The remaining sample materials for this project will be retained for a minimum of 90 days as directed by the Geotechnics’ Quality Program. We are pleased to provide these testing services. Should you have any questions or if we may be of further assistance, please contact our office. Respectively submitted, Geotechnics, Inc. Michael P. Smith Regional Manager We understand that you have a choice in your laboratory services and we thank you for choosing Geotechnics. 2200 Westinghouse Blvd., Suite 103 • Raleigh, NC 27604 • Phone (919) 876-0405 • Fax (919) 876-0460 • www.geotechnics.net MOISTURE CONTENT ASTM D 2216-10 Client:CDM SMITH, INC. Client Reference: DARE COUNTY C & D LF Project No.: 2015-775-001 Lab ID:001 002 Boring No.:STOCKPILE STOCKPILE Depth (ft):NA NA Sample No.:N S Tare Number 152 158 Wt. of Tare & Wet Sample (g) 624.67 602.10 Wt. of Tare & Dry Sample (g) 544.90 562.19 Weight of Tare (g)239.08 238.81 Weight of Water (g)79.77 39.91 Weight of Dry Sample (g)305.82 323.38 Water Content (%)26.1 12.3 Notes : Tested By NE Date 11/13/15 Checked By GEM Date 11/17/15 page 1 of 1 DCN: CT-S1 DATE: 3/18/13 REVISION: 4 2200 Westinghouse Blvd., Suite 103 • Raleigh, NC 27604 • Phone (919) 876-0405 • Fax (919) 876-0460 • www.geotechnics.net ATTERBERG LIMITS ASTM D 4318-10 / AASHTO T89-10 Client:CDM SMITH, INC.Boring No.:STOCKPILE Client Reference: DARE COUNTY C&D LF Depth (ft):NA Project No.: 2015-775-001 Sample No.: N Lab ID:2015-775-001-001 Soil Description:DARK GRAY LEAN CLAY Note: The USCS symbol used with this test refers only to the minus No. 40 ( Minus No. 40 sieve material, Airdried) sieve material. See the "Sieve and Hydrometer Analysis" graph page for the complete material description . Liquid Limit Test 1 2 3 M Tare Number J BA-K U Wt. of Tare & Wet Sample (g) 31.27 32.78 32.68 L Wt. of Tare & Dry Sample (g) 27.51 28.50 28.39 T Wt. of Tare (g) 15.16 15.21 15.56 I Wt. of Water (g) 3.8 4.3 4.3 P Wt. of Dry Sample (g) 12.4 13.3 12.8 O I Moisture Content (%) 30.4 32.2 33.4 N Number of Blows 33 23 15 T Plastic Limit Test 1 2 Range Test Results Tare Number K B-B Liquid Limit (%) 32 Wt. of Tare & Wet Sample (g) 25.37 25.43 Wt. of Tare & Dry Sample (g) 23.80 23.94 Plastic Limit (%) 18 Wt. of Tare (g) 15.24 15.61 Wt. of Water (g) 1.6 1.5 Plasticity Index (%) 14 Wt. of Dry Sample (g) 8.6 8.3 USCS Symbol CL Moisture Content (%) 18.3 17.9 0.5 Note: The acceptable range of the two Moisture contents is ± 2.6 Flow Curve Plasticity Chart Tested By TB Date 11/13/15 Checked By GEM Date 11/16/15 page 1 of 1 DCN:CT-S4B DATE:3/18/13 REVISION:4 3ptlimit.xls 20 22 24 26 28 30 32 34 36 110100 Wa t e r C o n t e n t ( % ) Number of Blows 0 10 20 30 40 50 60 0 20406080100 Pl a s t i c i t y I n d e x ( % ) Liquid Limit (%) CL CH MH CL-ML ML 2200 Westinghouse Blvd., Suite 103 • Raleigh, NC 27604 • Phone (919) 876-0405 • Fax (919) 876-0460 • www.geotechnics.net SIEVE ANALYSIS ASTM D 6913-04 Client: CDM SMITH, INC. Boring No.: STOCKPILE Client Reference: DARE COUNTY C & D LF Depth (ft): NA Project No.: 2015-775-001 Sample No.: N Lab ID: 2015-775-001-001 Soil Color: DARK GRAY SIEVE ANALYSIS HYDROMETER USCS gravel sand silt and clay USCS Symbol: CL, TESTED USCS Classification:LEAN CLAY WITH SAND Tested By NE Date 11/13/15 Checked By GEM Date 11/16/15 page 1 of 2 DCN: CT-S3C DATE 3/20/13 REVISION: 3 0 10 20 30 40 50 60 70 80 90 100 0.0010.010.11101001000 Pe r c e n t F i n e r B y W e i g h t ( % ) Particle Diameter (mm) 12"6" 3" 3/4" 3/8" #4 #10 #20 #40 #140 #200 2200 Westinghouse Blvd., Suite 103 • Raleigh, NC 27604 • Phone (919) 876-0405 • Fax (919) 876-0460 • www.geotechnics.net WASH SIEVE ANALYSIS ASTM D 6913-04 Client:CDM SMITH, INC.Boring No.:STOCKPILE Client Reference: DARE COUNTY C & D LF Depth (ft):NA Project No.: 2015-775-001 Sample No.: N Lab ID: 2015-775-001-001 Soil Color:DARK GRAY Moisture Content of Passing 3/4" Sample Water Content of Retained 3/4" Sample Tare No.152 Tare No.NA Wt. of Tare & Wet Sample (g) 624.67 Weight of Tare & Wet Sample (g)NA Wt. of Tare & Dry Sample (g) 544.90 Weight of Tare & Dry Sample (g)NA Weight of Tare (g)239.08 Weight of Tare (g)NA Weight of Water (g)79.77 Weight of Water (g)NA Weight of Dry Sample (g) 305.82 Weight of Dry Sample (g)NA Moisture Content (%)26.1 Moisture Content (%)NA Wet Weight of -3/4" Sample (g) NA Weight of the Dry Sample (g)305.82 Dry Weight of - 3/4" Sample (g) 78.3 Weight of - #200 Sample (g)227.49 Wet Weight of +3/4" Sample (g) NA Weight of + #200 Sample (g)78.33 Dry Weight of + 3/4" Sample (g) 0.00 Total Dry Weight of Sample (g) NA Sieve Sieve Weight of Soil Percent Accumulated Percent Accumulated Size Opening Retained Retained Percent Finer Percent Retained Finer (mm)(g)(%) (%)(%) (%) 12" 300 0.00 0.00 0.00 100.00 100.00 6" 150 0.00 0.00 0.00 100.00 100.00 3" 75 0.00 0.00 0.00 100.00 100.00 2" 50 0.00 0.00 0.00 100.00 100.00 1 1/2" 37.5 0.00 0.00 0.00 100.00 100.00 1" 25.0 0.00 0.00 0.00 100.00 100.00 3/4" 19.0 0.00 0.00 0.00 100.00 100.00 1/2" 12.50 0.00 0.00 0.00 100.00 100.00 3/8" 9.50 0.00 0.00 0.00 100.00 100.00 #4 4.75 0.00 0.00 0.00 100.00 100.00 #10 2.00 0.21 0.07 0.07 99.93 99.93 #20 0.850 0.72 0.24 0.30 99.70 99.70 #40 0.425 1.51 0.49 0.80 99.20 99.20 #60 0.250 3.59 1.17 1.97 98.03 98.03 #140 0.106 0.00 0.00 1.97 98.03 98.03 #200 0.075 72.30 23.64 25.61 74.39 74.39 Pan -227.49 74.39 100.00 -- Tested By NE Date 11/13/15 Checked By GEM Date 11/16/15 page 2 of 2 DCN: CT-S3C DATE 3/20/13 REVISION: 3 2200 Westinghouse Blvd., Suite 103 • Raleigh, NC 27604 • Phone (919) 876-0405 • Fax (919) 876-0460 • www.geotechnics.net MOISTURE DENSITY RELATIONSHIP ASTM D698-12 Client:CDM SMITH, INC.Boring No.: STOCKPILE Client Reference: DARE COUNTY C&D LF Depth (ft): NA Project No.:2015-775-001 Sample No.: N Lab ID:2015-775-001-001 Test Method STANDARD Visual Description: DARK GRAY LEAN CLAY WITH SAND Optimum Water Content 16.5 Maximum Dry Density 110.6 Tested By AF Date 11/16/15 Checked By GEM Date 11/17/15 page 1 of 2 DCN:CT-S12 DATE:5/1/13 REVISION: 14 95 100 105 110 115 0 5 10 15 20 25 30 De n s i t y ( p c f ) Water Content (%) Specific Gravity 2.70 Assumed 2200 Westinghouse Blvd., Suite 103 • Raleigh, NC 27604 • Phone (919) 876-0405 • Fax (919) 876-0460 • www.geotechnics.net MOISTURE - DENSITY RELATIONSHIP ASTM D698-12 Client:CDM SMITH, INC.Boring No.: STOCKPILE Client Reference: DARE COUNTY C&D LF Depth (ft): NA Project No.:2015-775-001 Sample No.: N Lab ID:2015-775-001-001 Visual Description: DARK GRAY LEAN CLAY WITH SAND Total Weight of the Sample (g) 24650 Test Type STANDARD As Received Water Content (%) NA Rammer Weight (lb)5.5 Assumed Specific Gravity 2.70 Rammer Drop (in)12 Rammer Type MECHANICAL Percent Retained on 3/4" NA Machine ID R 174 Percent Retained on 3/8" NA Mold ID R 461 Percent Retained on #4 NA Mold diameter 4" Oversize Material Not included Weight of the Mold (g)4163 Procedure Used A Volume of the Mold (cm3)942 Mold / Specimen Point No.123 4 5 Wt. of Mold & Wet Sample (g) 5796 5904 6034 6115 6070 Wt.of Mold (g) 4163 4163 4163 4163 4163 Wt. of Wet Sample (g) 1633 1741 1871 1952 1907 Mold Volume (cm3)942 942 942 942 942 Moisture Content / Density Tare Number 399 312 319 820 866 Wt. of Tare & Wet Sample (g) 536.40 671.00 726.30 744.40 484.00 Wt. of Tare & Dry Sample (g) 505.40 614.20 663.60 666.00 417.60 Wt. of Tare (g)88.60 84.30 209.10 208.10 86.50 Wt. of Water (g)31.00 56.80 62.70 78.40 66.40 Wt. of Dry Sample (g)416.80 529.90 454.50 457.90 331.10 Wet Density (g/cm3)1.73 1.85 1.99 2.07 2.02 Wet Density (pcf) 108.2 115.3 123.9 129.3 126.4 Moisture Content (%) 7.4 10.7 13.8 17.1 20.1 Dry Density (pcf) 100.7 104.2 108.9 110.4 105.2 Zero Air Voids Moisture Content (%)18.5 22.0 25.0 Dry Unit Weight (pcf)112.4 105.7 100.6 Tested By AF Date 11/16/15 Checked By GEM Date 11/17/15 page 2 of 2 DCN:CT-S12 DATE:5/1/13 REVISION: 14 PROCTOR.xls 2200 Westinghouse Blvd., Suite 103 • Raleigh, NC 27604 • Phone (919) 876-0405 • Fax (919) 876-0460 • www.geotechnics.net CONSOLIDATED UNDRAINED TRIAXIAL TEST WITH PORE PRESSURE READINGS ASTM D4767-11 Client:CDM SMITH, INC.Boring No.:STOCKPILE Client Reference: DARE COUNTY C&D LF Depth (ft):N/A Project No.:2015-775-001 Sample No.: N Lab ID:2015-775-001-001 a =0.00 C =0.00 30.2 35.60 Tested By: AF Date: 12/7/15 Approved By: MPS Date: 12/14/15 page 1 of 12 DCN: CT-S28 DATE: 4/12/13 REVISION: 3 Sigmatriax.xls 0 2 4 6 8 10 12 14 16 18 0 5 10 15 20 25 30 Q, ( p s i ) P, (psi) Consolidated Undrained Triaxial Test with Pore Pressure Max. Effec. Stress Ratio Points Failure Envelope Test No. 1 Test No. 2 Test No. 3  2200 Westinghouse Blvd., Suite 103 • Raleigh, NC 27604 • Phone (919) 876-0405 • Fax (919) 876-0460 • www.geotechnics.net MOHR TOTAL STRENGTH ENVELOPE ASTM D4767-11 Client:CDM SMITH, INC.Boring No.:STOCKPILE Client Reference: DARE COUNTY C&D LF Depth (ft):N/A Project No.: 2015-775-001 Sample No.: N Lab ID:2015-775-001-001 Visual Description: DARK GRAY LEAN CLAY WITH SAND (REMOLDED) Failure Based on Maximum Effective Principal Stress Ratio NOTE: GRAPH NOT TO SCALE Tested By:AF Date:12/7/15 Approved By: MPS Date:12/14/15 page 2 of 12 DCN: CT-S28 DATE: 4/12/13 REVISION: 3 0 5 10 15 20 25 30 35 0 5 10 15 20 25 30 35 40  (p s i ) (psi) c = = 1.87 19.61 2200 Westinghouse Blvd., Suite 103 • Raleigh, NC 27604 • Phone (919) 876-0405 • Fax (919) 876-0460 • www.geotechnics.net CONSOLIDATED UNDRAINED TRIAXIAL TEST WITH PORE PRESSURE READINGS ASTM D4767-11 Client:CDM SMITH, INC.Boring No.:STOCKPILE Client Reference: DARE COUNTY C&D LF Depth (ft):N/A Project No.:2015-775-001 Sample No.:N Lab ID:2015-775-001-001 Visual Description: DARK GRAY LEAN CLAY WITH SAND (REMOLDED) Stage No.1 INITIAL SAMPLE DIMENSIONS (in) Test No.1 Length 1: 5.995 Diameter 1: 2.864 PRESSURES (psi)Length 2: 5.995 Diameter 2: 2.864 Length 3: 5.995 Diameter 3: 2.864 Cell Pressure (psi)55.0 Avg. Length:5.995 Avg. Diam.:2.864 Back Pressure (psi)50.0 Eff. Conf. Pressure (psi) 5.0 VOLUME CHANGE Pore Pressure Initial Burette Reading (ml)17.0 Response (%)99 Final Burette Reading (ml)8.2 Final Change (ml)8.8 MAXIMUM OBLIQUITY POINTS Initial Dial Reading (mil)135 P =8.32 Dial Reading After Saturation (mil) 135 Q =5.17 Dial Reading After Consolidation (mil)137 LOAD DEFORMATION PORE PRESSURE (LB) (IN) (PSI) 8.4 0.000 50.0 10.5 0.001 50.0 11.2 0.002 50.0 11.6 0.009 50.0 24.6 0.014 50.2 31.6 0.020 50.737.0 0.029 51.240.4 0.038 51.6 43.8 0.050 51.8 48.6 0.071 52.1 53.9 0.101 52.2 60.1 0.137 52.2 66.2 0.173 52.1 72.5 0.215 52.0 76.9 0.245 51.8 83.0 0.287 51.6 92.1 0.344 51.2 101.0 0.403 50.8 107.5 0.449 50.5 114.5 0.509 50.2 121.0 0.555 49.9 127.2 0.600 49.5 133.1 0.644 49.2 136.8 0.674 49.0 140.1 0.704 48.8 143.0 0.734 48.6 146.5 0.764 48.4 152.5 0.810 48.0 157.4 0.855 47.7 160.6 0.884 47.5 164.3 0.914 47.3 Tested By: AF Date: 12/7/15 Input Checked By: GEM Date: 12/14/15 page 3 of 12 DCN: CT-S28 DATE: 4/12/13 REVISION: 3 Sigmatriax.xls 2200 Westinghouse Blvd., Suite 103 • Raleigh, NC 27604 • Phone (919) 876-0405 • Fax (919) 876-0460 • www.geotechnics.net CONSOLIDATED UNDRAINED TRIAXIAL TEST WITH PORE PRESSURE READINGS ASTM D4767-11 Client:CDM SMITH, INC.Boring No.:STOCKPILE Client Reference: DARE COUNTY C&D LF Depth (ft):N/A Project No.: 2015-775-001 Sample No.: N Lab ID:2015-775-001-001 Visual Description: DARK GRAY LEAN CLAY WITH SAND (REMOLDED) Effective Confining Pressure (psi)5.0 Stage No.1 Test No 1 INITIAL DIMENSIONS VOLUME CHANGE Initial Sample Length (in) 6.00 Volume After Consolidation (in3)38.08 Initial Sample Diameter (in)2.86 Length After Consolidation (in)5.99 Initial Sample Area (in2)6.44 Area After Consolidation (in2)6.355 Initial Sample Volume (in3)38.62 Strain Deviation U Effective Principle APQ (%) Stress Stress Ratio 0.02 0.33 -0.01 5.32 5.0 1.066 -0.02 5.16 0.16 0.04 0.45 -0.01 5.44 5.0 1.091 -0.02 5.22 0.23 0.14 0.51 0.00 5.49 5.0 1.102 -0.01 5.24 0.25 0.24 2.55 0.24 7.29 4.7 1.537 0.09 6.02 1.27 0.34 3.64 0.68 7.94 4.3 1.846 0.19 6.12 1.820.48 4.48 1.23 8.23 3.8 2.193 0.28 5.99 2.240.63 5.01 1.58 8.41 3.4 2.473 0.32 5.91 2.50 0.84 5.54 1.81 8.70 3.2 2.748 0.33 5.94 2.77 1.19 6.26 2.05 9.19 2.9 3.132 0.33 6.06 3.13 1.69 7.04 2.16 9.86 2.8 3.496 0.31 6.34 3.52 2.29 7.95 2.19 10.75 2.8 3.842 0.28 6.77 3.98 2.89 8.84 2.12 11.70 2.9 4.086 0.24 7.28 4.42 3.59 9.73 1.95 12.76 3.0 4.204 0.20 7.90 4.86 4.08 10.34 1.83 13.49 3.1 4.284 0.18 8.32 5.17 4.79 11.18 1.56 14.61 3.4 4.269 0.14 9.01 5.59 5.75 12.42 1.20 16.20 3.8 4.285 0.10 9.99 6.21 6.73 13.60 0.80 17.79 4.2 4.248 0.06 10.99 6.80 7.49 14.43 0.54 18.87 4.4 4.243 0.04 11.66 7.21 8.49 15.29 0.14 20.13 4.8 4.158 0.01 12.49 7.64 9.26 16.08 -0.16 21.23 5.1 4.128 -0.01 13.18 8.04 10.00 16.82 -0.48 22.29 5.5 4.080 -0.03 13.87 8.41 10.74 17.52 -0.81 23.31 5.8 4.023 -0.05 14.55 8.76 11.25 17.94 -0.98 23.90 6.0 4.006 -0.06 14.93 8.97 11.75 18.29 -1.18 24.46 6.2 3.967 -0.07 15.31 9.15 12.25 18.59 -1.43 25.00 6.4 3.901 -0.08 15.71 9.30 12.75 18.96 -1.64 25.59 6.6 3.862 -0.09 16.11 9.48 13.51 19.61 -1.98 26.58 7.0 3.815 -0.10 16.77 9.81 14.26 20.11 -2.28 27.37 7.3 3.770 -0.11 17.31 10.05 14.76 20.42 -2.49 27.90 7.5 3.731 -0.12 17.69 10.21 15.25 20.79 -2.76 28.53 7.7 3.686 -0.13 18.14 10.40 page 4 of 12 2200 Westinghouse Blvd., Suite 103 • Raleigh, NC 27604 • Phone (919) 876-0405 • Fax (919) 876-0460 • www.geotechnics.net CONSOLIDATED UNDRAINED TRIAXIAL TEST WITH PORE PRESSURE READINGS ASTM D4767-11 Client:CDM SMITH, INC.Boring No.:STOCKPILE Client Reference: DARE COUNTY C&D LF Depth (ft):N/A Project No.:2015-775-001 Sample No.:N Lab ID:2015-775-001-001 Visual Description: DARK GRAY LEAN CLAY WITH SAND (REMOLDED) Stage No.1 INITIAL SAMPLE DIMENSIONS (in) Test No.2 Length 1: 5.995 Diameter 1: 2.864 PRESSURES (psi)Length 2: 5.995 Diameter 2: 2.864Length 3: 5.995 Diameter 3: 2.864 Cell Pressure (psi)60.0 Avg. Length 5.995 Avg. Diam.:2.864 Back Pressure (psi)50.0 Eff. Conf. Pressure (psi) 10.0 VOLUME CHANGE Pore Pressure Initial Burette Reading (ml)16.6 Response (%)99 Final Burette Reading (ml)3.8 Final Change (ml)12.8 MAXIMUM OBLIQUITY POINTS Initial Dial Reading (mil)280 P =12.44 Dial Reading After Saturation (mil)311 Q =7.93 Dial Reading After Consolidation (mil)347 LOAD DEFORMATION PORE PRESSURE (LB)(IN)(PSI) 11.0 0.000 50.014.1 0.001 50.0 19.1 0.003 49.9 21.0 0.008 50.440.5 0.014 51.848.9 0.019 53.0 54.6 0.028 54.158.7 0.037 54.862.6 0.048 55.4 68.2 0.069 55.9 74.4 0.099 56.380.2 0.135 56.4 87.2 0.171 56.4 90.9 0.213 56.398.0 0.242 56.1 106.6 0.283 55.8 116.8 0.340 55.5126.9 0.400 55.0 133.2 0.444 54.7 141.3 0.503 54.3149.5 0.548 53.9 155.9 0.593 53.6 160.6 0.637 53.3163.0 0.667 53.1 166.6 0.697 52.9 169.5 0.726 52.6173.9 0.756 52.4 178.1 0.802 52.2 182.0 0.846 51.9183.7 0.875 51.7187.3 0.905 51.5 Tested By: AF Date: 12/7/15 Input Checked By: GEM Date: 12/14/15 page 5 of 12 DCN: CT-S28 DATE: 4/12/13 REVISION: 3 2200 Westinghouse Blvd., Suite 103 • Raleigh, NC 27604 • Phone (919) 876-0405 • Fax (919) 876-0460 • www.geotechnics.net CONSOLIDATED UNDRAINED TRIAXIAL TEST WITH PORE PRESSURE READINGS ASTM D4767-11 Client:CDM SMITH, INC.Boring No.:STOCKPILE Client Reference: DARE COUNTY C&D LF Depth (ft):N/A Project No.: 2015-775-001 Sample No.: N Lab ID:2015-775-001-001 Visual Description: DARK GRAY LEAN CLAY WITH SAND (REMOLDED) Effective Confining Pressure (psi)10.0 Stage No.1 Test No 2 INITIAL DIMENSIONS VOLUME CHANGE Initial Sample Length (in)6.00 Volume After Consolidation (in3)37.24 Initial Sample Diameter (in)2.86 Length After Consolidation (in)5.93 Initial Sample Area (in2)6.44 Area After Consolidation (in2)6.282 Initial Sample Volume (in3)38.62 Strain Deviation U Effective Principle A PQ (%) Stress Stress Ratio 0.02 0.49 -0.04 10.53 10.0 1.049 -0.08 10.28 0.25 0.04 1.29 -0.06 11.35 10.1 1.128 -0.05 10.71 0.64 0.14 1.59 0.39 11.19 9.6 1.165 0.25 10.40 0.790.23 4.69 1.82 12.86 8.2 1.573 0.39 10.52 2.340.33 6.00 2.97 13.03 7.0 1.855 0.50 10.03 3.00 0.47 6.91 4.14 12.77 5.9 2.179 0.60 9.32 3.46 0.62 7.54 4.81 12.73 5.2 2.452 0.64 8.96 3.770.81 8.15 5.43 12.72 4.6 2.783 0.67 8.64 4.07 1.16 8.99 5.96 13.04 4.0 3.226 0.67 8.54 4.50 1.68 9.92 6.31 13.61 3.7 3.686 0.64 8.65 4.962.28 10.76 6.46 14.30 3.5 4.038 0.61 8.92 5.38 2.88 11.78 6.37 15.41 3.6 4.243 0.55 9.52 5.89 3.59 12.26 6.27 15.99 3.7 4.287 0.52 9.86 6.134.08 13.27 6.12 17.15 3.9 4.422 0.47 10.52 6.64 4.78 14.48 5.83 18.66 4.2 4.472 0.41 11.41 7.24 5.74 15.87 5.49 20.37 4.5 4.522 0.35 12.44 7.936.75 17.21 5.04 22.16 5.0 4.473 0.30 13.56 8.60 7.49 17.99 4.70 23.29 5.3 4.394 0.26 14.30 9.00 8.48 18.99 4.26 24.72 5.7 4.310 0.23 15.23 9.499.24 20.00 3.94 26.06 6.1 4.302 0.20 16.06 10.00 10.01 20.76 3.59 27.17 6.4 4.241 0.17 16.79 10.38 10.75 21.25 3.30 27.95 6.7 4.171 0.16 17.32 10.6211.25 21.47 3.08 28.39 6.9 4.105 0.15 17.65 10.74 11.75 21.85 2.86 28.99 7.1 4.063 0.13 18.06 10.93 12.25 22.14 2.66 29.48 7.3 4.017 0.12 18.41 11.0712.76 22.63 2.40 30.23 7.6 3.977 0.11 18.91 11.31 13.52 23.00 2.20 30.81 7.8 3.948 0.10 19.30 11.50 14.27 23.34 1.87 31.47 8.1 3.871 0.08 19.80 11.6714.77 23.44 1.71 31.72 8.3 3.828 0.07 20.00 11.7215.26 23.77 1.56 32.22 8.4 3.816 0.07 20.33 11.89 page 6 of 12 2200 Westinghouse Blvd., Suite 103 • Raleigh, NC 27604 • Phone (919) 876-0405 • Fax (919) 876-0460 • www.geotechnics.net CONSOLIDATED UNDRAINED TRIAXIAL TEST WITH PORE PRESSURE READINGS ASTM D4767-11 Client:CDM SMITH, INC.Boring No.:STOCKPILE Client Reference: DARE COUNTY C&D LF Depth (ft):N/A Project No.:2015-775-001 Sample No.:N Lab ID:2015-775-001-001 Visual Description: DARK GRAY LEAN CLAY WITH SAND (REMOLDED) Stage No.1 INITIAL SAMPLE DIMENSIONS (in) Test No.3 Length 1: 5.995 Diameter 1: 2.864 PRESSURES (psi)Length 2: 5.995 Diameter 2: 2.864Length 3: 5.995 Diameter 3: 2.864 Cell Pressure (psi)65.0 Avg. Length:5.995 Avg. Diam.:2.864 Back Pressure (psi)50.0 Eff. Conf. Pressure (psi) 15.0 VOLUME CHANGE Pore Pressure Initial Burette Reading (ml)24.0 Response (%)99 Final Burette Reading (ml)9.4 Final Change (ml)14.6 MAXIMUM OBLIQUITY POINTS Initial Dial Reading (mil)26 P =17.01 Dial Reading After Saturation (mil)146 Q =10.23 Dial Reading After Consolidation (mil)190 LOAD DEFORMATION PORE PRESSURE (LB)(IN)(PSI) 11.5 0.000 50.013.3 0.001 50.015.2 0.003 50.041.9 0.007 51.6 58.0 0.014 53.4 67.7 0.019 54.8 75.6 0.028 56.280.5 0.036 57.186.1 0.048 57.991.4 0.068 58.6 98.1 0.097 59.1 105.7 0.131 59.2 114.9 0.167 59.2 122.7 0.208 59.0127.4 0.237 58.9134.0 0.277 58.6 143.2 0.332 58.2 151.8 0.390 57.8 159.1 0.434 57.5 166.2 0.491 57.1172.1 0.534 56.8178.5 0.579 56.5183.8 0.622 56.2 187.0 0.651 56.0 189.9 0.680 55.9 191.0 0.708 55.7194.4 0.737 55.5199.9 0.782 55.3203.3 0.825 55.1 206.7 0.854 55.0 208.1 0.882 54.8 Tested By: AF Date: 12/7/15 Input Checked By: GEM Date: 12/14/15 page 7 of 12 DCN: CT-S28 DATE: 4/12/13 REVISION: 3 2200 Westinghouse Blvd., Suite 103 • Raleigh, NC 27604 • Phone (919) 876-0405 • Fax (919) 876-0460 • www.geotechnics.net CONSOLIDATED UNDRAINED TRIAXIAL TEST WITH PORE PRESSURE READINGS ASTM D4767-11 Client:CDM SMITH, INC.Boring No.:STOCKPILE Client Reference: DARE COUNTY C&D LF Depth (ft):N/A Project No.: 2015-775-001 Sample No.: N Lab ID:2015-775-001-001 Visual Description: DARK GRAY LEAN CLAY WITH SAND (REMOLDED) Effective Confining Pressure (psi)15.0 Stage No.1 Test No 3 INITIAL DIMENSIONS VOLUME CHANGE Initial Sample Length (in) 6.00 Volume After Consolidation (in 3)35.41 Initial Sample Diameter (in)2.86 Length After Consolidation (in)5.83 Initial Sample Area (in2)6.44 Area After Consolidation (in2)6.073 Initial Sample Volume (in3)38.62 Strain Deviation U Effective Principle A PQ (%) Stress Stress Ratio 0.02 0.30 0.00 15.29 15.0 1.020 0.00 15.14 0.150.04 0.62 -0.02 15.63 15.0 1.041 -0.03 15.32 0.310.13 5.00 1.56 18.43 13.4 1.372 0.32 15.93 2.50 0.23 7.65 3.38 19.27 11.6 1.658 0.45 15.44 3.83 0.33 9.23 4.79 19.44 10.2 1.905 0.52 14.82 4.62 0.47 10.51 6.21 19.30 8.8 2.196 0.60 14.04 5.260.62 11.29 7.09 19.19 7.9 2.429 0.63 13.55 5.640.82 12.19 7.85 19.33 7.1 2.706 0.65 13.24 6.091.17 13.00 8.60 19.40 6.4 3.032 0.67 12.90 6.50 1.66 14.03 9.07 19.95 5.9 3.368 0.65 12.94 7.01 2.25 15.17 9.22 20.94 5.8 3.628 0.61 13.35 7.58 2.86 16.54 9.20 22.34 5.8 3.854 0.56 14.07 8.27 3.56 17.66 9.04 23.62 6.0 3.963 0.52 14.79 8.834.06 18.32 8.88 24.43 6.1 3.997 0.49 15.27 9.164.75 19.21 8.61 25.60 6.4 4.009 0.45 15.99 9.61 5.69 20.46 8.22 27.24 6.8 4.018 0.41 17.01 10.23 6.69 21.56 7.79 28.77 7.2 3.992 0.36 17.99 10.78 7.44 22.50 7.48 30.02 7.5 3.994 0.34 18.77 11.25 8.43 23.33 7.07 31.25 7.9 3.945 0.31 19.59 11.679.16 24.03 6.78 32.24 8.2 3.925 0.29 20.23 12.019.92 24.78 6.48 33.29 8.5 3.909 0.26 20.90 12.3910.67 25.34 6.23 34.11 8.8 3.890 0.25 21.44 12.67 11.17 25.68 6.04 34.63 9.0 3.869 0.24 21.79 12.84 11.66 25.96 5.88 35.08 9.1 3.847 0.23 22.10 12.98 12.14 25.98 5.71 35.26 9.3 3.799 0.22 22.27 12.9912.65 26.31 5.54 35.77 9.5 3.783 0.21 22.61 13.1613.41 26.87 5.33 36.54 9.7 3.780 0.20 23.10 13.4414.15 27.12 5.10 37.01 9.9 3.741 0.19 23.45 13.56 14.64 27.45 4.97 37.47 10.0 3.737 0.18 23.75 13.72 15.13 27.47 4.84 37.63 10.2 3.706 0.18 23.89 13.74 page 8 of 12 2200 Westinghouse Blvd., Suite 103 • Raleigh, NC 27604 • Phone (919) 876-0405 • Fax (919) 876-0460 • www.geotechnics.net CONSOLIDATED UNDRAINED TRIAXIAL TEST WITH PORE PRESSURE READINGS ASTM D4767-11 Client:CDM SMITH, INC.Boring No.:STOCKPILE Client Reference:DARE COUNTY C&D LF Depth (ft):N/A Project No.:2015-775-001 Sample No.:N Lab ID:2015-775-001-001 Visual Description: DARK GRAY LEAN CLAY WITH SAND (REMOLDED) Tested By: AF Date: 12/7/15 Approved By: MPS Date: 12/14/15 page 9 of 12 0 5 10 15 20 25 30 024681012141618 De v i a t o r S t r e s s ( p s i ) Strain (%) Test No. 1 Test No. 2 Test No. 3 2200 Westinghouse Blvd., Suite 103 • Raleigh, NC 27604 • Phone (919) 876-0405 • Fax (919) 876-0460 • www.geotechnics.net CONSOLIDATED UNDRAINED TRIAXIAL TEST WITH PORE PRESSURE READINGS ASTM D4767-11 Client:CDM SMITH, INC. Client Reference: DARE COUNTY C&D LF Project No.: 2015-775-001 Lab ID:2015-775-001-001 Specific Gravity (assumed) 2.7 Visual Description: DARK GRAY LEAN CLAY WITH SAND (REMOLDED) SAMPLE CONDITION SUMMARY Boring No.:STOCKPILE STOCKPILE STOCKPILE Depth (ft):N/A N/A N/A Sample No.:N N N Test No.T1T2T3 Deformation Rate (in/min)0.0007 0.0007 0.0007 Back Pressure (psi)50.0 50.0 50.0 Consolidation Time (days)1 1 1 Moisture Content (%) (INITIAL)26.4 26.4 26.4 Total Unit Weight (pcf)123.0 123.0 123.1 Dry Unit Weight (pcf)97.3 97.3 97.4 Moisture Content (%) (FINAL)23.3 23.0 23.5 Initial State Void Ratio,e 0.732 0.731 0.731 Void Ratio at Shear, e 0.709 0.670 0.587 Tested By:AF Date: 12/7/15 Input Checked By: GEM Date: 12/14/15 page 10 of 12 DCN: CT-S28 DATE: 4/12/13 REVISION: 3 2200 Westinghouse Blvd., Suite 103 • Raleigh, NC 27604 • Phone (919) 876-0405 • Fax (919) 876-0460 • www.geotechnics.net CONSOLIDATED UNDRAINED TRIAXIAL TEST WITH PORE PRESSURE READINGS ASTM D4767-11 MOISTURE CONTENT T1 T2 T3 Tare Number 810 810 810 Weight of Tare & Wet Sample (g)373.64 373.64 373.64 Weight of Tare & Dry Sample (g)319.17 319.17 319.17 Weight of Tare (g)112.78 112.78 112.78 Moisture Content (%) (INITIAL)26.39 26.39 26.39 Tare Number 810 TB-11 TB-06 Weight of Tare & Wet Sample (g)710.24 725.4 690.36 Weight of Tare & Dry Sample (g)597.48 614.89 584.77 Weight of Tare (g)112.81 135.33 134.72 Moisture Content (%) (FINAL)23.27 23.04 23.46 UNIT WEIGHT Weight of Tube & Wet Sample (g)2800.02 2800.78 2801.04 Weight of Tube (g)1553.52 1553.52 1553.52 Weight of Wet Sample (g)1246.5 1247.26 1247.52 Length 1 (in)5.995 5.995 5.995 Length 2 (in)5.995 5.995 5.995 Length 3 (in)5.995 5.995 5.995 Top Diameter (in)2.864 2.864 2.864 Middle Diameter (in)2.864 2.864 2.864 Bottom Diameter (in)2.864 2.864 2.864 Average Length (in)5.995 5.995 5.995 Average Area (in)6.442 6.442 6.442 Sample Volume (cm3)632.89 632.89 632.89 Unit Wet Weight (g/cm3)1.97 1.97 1.97 Unit Wet Weight (pcf)122.96 123.03 123.06 Unit Dry Weight (pcf)97.28 97.34 97.36 Unit Dry Weight (g/cm3)1.56 1.56 1.56 Initial Burette Reading 17 16.6 24 Final Burette Reading 8.2 3.8 9.4 Initial Dial Reading 135 280 26 Dial Reading After Saturation 135 311 146 Dial Reading After Consolidation 137 347 190 Volume Change during Consolidation 8.8 12.8 14.6 Volume Change during Saturation 0.00 9.82 38.00 Volume at Shear (cm3)*These 624.09 610.27 580.28 Volume of Solids (cm3) measurements 365.27 365.49 365.57 Volume of Voids (cm3)are all 258.82 244.78 214.72 Volume of Water (cm3) at 229.45 227.40 231.57 Void Ratio, e shear 0.709 0.670 0.587 page 11 of 12 DCN: CT-S28 DATE: 4/12/13 REVISION: 3 2200 Westinghouse Blvd., Suite 103 • Raleigh, NC 27604 • Phone (919) 876-0405 • Fax (919) 876-0460 • www.geotechnics.net CONSOLIDATED UNDRAINED TRIAXIAL TEST WITH PORE PRESSURE READINGS ASTM D4767-11 Client: CDM SMITH, INC. Boring No.: STOCKPILE Client Reference: DARE COUNTY C&D LF Depth (ft): N/A Project No.: 2015-775-001 Sample No.: N Lab ID: 2015-775-001-001 TEST 1 INITIAL TEST 1 FINAL TEST 2 INITIAL TEST 2 FINAL TEST 3 INITIAL TEST 3 FINAL Tested By AF Date 12/7/15 Approved By MPS Date 12/14/15 page 12 of 12 DCN: CT-S28 DATE: 4/12/13 REVISION: 3 Z:\2015 PROJECTS\2015-775 CDM SMITH - DARE COUNTY C&D LF\[2015-775-001-001 SIGMATRIAX.xlsm]PHOTOS N/A N/A N/A 2200 Westinghouse Blvd., Suite 103 • Raleigh, NC 27604 • Phone (919) 876-0405 • Fax (919) 876-0460 • www.geotechnics.net ATTERBERG LIMITS ASTM D 4318-10 / AASHTO T89-10 Client:CDM SMITH, INC.Boring No.:STOCKPILE Client Reference: DARE COUNTY C&D LF Depth (ft):NA Project No.: 2015-775-001 Sample No.: S Lab ID:2015-775-001-002 Soil Description:BROWN GRAY LEAN CLAY Note: The USCS symbol used with this test refers only to the minus No. 40 ( Minus No. 40 sieve material, Airdried) sieve material. See the "Sieve and Hydrometer Analysis" graph page for the complete material description . Liquid Limit Test 1 2 3 M Tare Number 2M A-T A U Wt. of Tare & Wet Sample (g) 33.66 33.77 32.27 L Wt. of Tare & Dry Sample (g) 29.82 29.83 28.39 T Wt. of Tare (g) 15.60 15.63 15.31 I Wt. of Water (g) 3.8 3.9 3.9 P Wt. of Dry Sample (g) 14.2 14.2 13.1 O I Moisture Content (%) 27.0 27.7 29.7 N Number of Blows 33 25 15 T Plastic Limit Test 1 2 Range Test Results Tare Number A-C 17 Liquid Limit (%) 28 Wt. of Tare & Wet Sample (g) 23.19 23.32 Wt. of Tare & Dry Sample (g) 22.08 22.21 Plastic Limit (%) 17 Wt. of Tare (g) 15.53 15.48 Wt. of Water (g) 1.1 1.1 Plasticity Index (%) 11 Wt. of Dry Sample (g) 6.6 6.7 USCS Symbol CL Moisture Content (%) 16.9 16.5 0.5 Note: The acceptable range of the two Moisture contents is ± 2.6 Flow Curve Plasticity Chart Tested By TB Date 11/13/15 Checked By GEM Date 11/16/15 page 1 of 1 DCN:CT-S4B DATE:3/18/13 REVISION:4 3ptlimit.xls 20 22 24 26 28 30 32 110100 Wa t e r C o n t e n t ( % ) Number of Blows 0 10 20 30 40 50 60 0 20406080100 Pl a s t i c i t y I n d e x ( % ) Liquid Limit (%) CL CH MH CL-ML ML 2200 Westinghouse Blvd., Suite 103 • Raleigh, NC 27604 • Phone (919) 876-0405 • Fax (919) 876-0460 • www.geotechnics.net SIEVE ANALYSIS ASTM D 6913-04 Client: CDM SMITH, INC. Boring No.: STOCKPILE Client Reference: DARE COUNTY C & D LF Depth (ft): NA Project No.: 2015-775-001 Sample No.: S Lab ID: 2015-775-001-002 Soil Color: BROWN GRAY SIEVE ANALYSIS HYDROMETER USCS gravel sand silt and clay USCS Symbol: CL, TESTED USCS Classification:SANDY LEAN CLAY Tested By NE Date 11/13/15 Checked By GEM Date 11/16/15 page 1 of 2 DCN: CT-S3C DATE 3/20/13 REVISION: 3 0 10 20 30 40 50 60 70 80 90 100 0.0010.010.11101001000 Pe r c e n t F i n e r B y W e i g h t ( % ) Particle Diameter (mm) 12"6" 3" 3/4" 3/8" #4 #10 #20 #40 #140 #200 2200 Westinghouse Blvd., Suite 103 • Raleigh, NC 27604 • Phone (919) 876-0405 • Fax (919) 876-0460 • www.geotechnics.net WASH SIEVE ANALYSIS ASTM D 6913-04 Client:CDM SMITH, INC.Boring No.:STOCKPILE Client Reference: DARE COUNTY C & D LF Depth (ft):NA Project No.: 2015-775-001 Sample No.: S Lab ID: 2015-775-001-002 Soil Color:BROWN GRAY Moisture Content of Passing 3/4" Sample Water Content of Retained 3/4" Sample Tare No.158 Tare No.NA Wt. of Tare & Wet Sample (g) 602.10 Weight of Tare & Wet Sample (g)NA Wt. of Tare & Dry Sample (g) 562.19 Weight of Tare & Dry Sample (g)NA Weight of Tare (g)238.81 Weight of Tare (g)NA Weight of Water (g)39.91 Weight of Water (g)NA Weight of Dry Sample (g) 323.38 Weight of Dry Sample (g)NA Moisture Content (%)12.3 Moisture Content (%)NA Wet Weight of -3/4" Sample (g) NA Weight of the Dry Sample (g)323.38 Dry Weight of - 3/4" Sample (g) 129.5 Weight of - #200 Sample (g)193.90 Wet Weight of +3/4" Sample (g) NA Weight of + #200 Sample (g)129.48 Dry Weight of + 3/4" Sample (g) 0.00 Total Dry Weight of Sample (g) NA Sieve Sieve Weight of Soil Percent Accumulated Percent Accumulated Size Opening Retained Retained Percent Finer Percent Retained Finer (mm)(g)(%) (%)(%) (%) 12" 300 0.00 0.00 0.00 100.00 100.00 6" 150 0.00 0.00 0.00 100.00 100.00 3" 75 0.00 0.00 0.00 100.00 100.00 2" 50 0.00 0.00 0.00 100.00 100.00 1 1/2" 37.5 0.00 0.00 0.00 100.00 100.00 1" 25.0 0.00 0.00 0.00 100.00 100.00 3/4" 19.0 0.00 0.00 0.00 100.00 100.00 1/2" 12.50 0.00 0.00 0.00 100.00 100.00 3/8" 9.50 0.00 0.00 0.00 100.00 100.00 #4 4.75 0.13 0.04 0.04 99.96 99.96 #10 2.00 4.52 1.40 1.44 98.56 98.56 #20 0.850 4.30 1.33 2.77 97.23 97.23 #40 0.425 6.47 2.00 4.77 95.23 95.23 #60 0.250 17.06 5.28 10.04 89.96 89.96 #140 0.106 19.82 6.13 16.17 83.83 83.83 #200 0.075 77.18 23.87 40.04 59.96 59.96 Pan -193.90 59.96 100.00 -- Tested By NE Date 11/13/15 Checked By GEM Date 11/16/15 page 2 of 2 DCN: CT-S3C DATE 3/20/13 REVISION: 3 2200 Westinghouse Blvd., Suite 103 • Raleigh, NC 27604 • Phone (919) 876-0405 • Fax (919) 876-0460 • www.geotechnics.net MOISTURE DENSITY RELATIONSHIP ASTM D698-12 Client:CDM SMITH, INC.Boring No.: STOCKPILE Client Reference: DARE COUNTY C&D LF Depth (ft): NA Project No.:2015-775-001 Sample No.: S Lab ID:2015-775-001-002 Test Method STANDARD Visual Description: BROWN GRAY SANDY LEAN CLAY Optimum Water Content 13.9 Maximum Dry Density 116.8 Tested By AF Date 11/17/15 Checked By GEM Date 11/18/15 page 1 of 2 DCN:CT-S12 DATE:5/1/13 REVISION: 14 100 105 110 115 120 0 5 10 15 20 25 30 De n s i t y ( p c f ) Water Content (%) Specific Gravity 2.70 Assumed 2200 Westinghouse Blvd., Suite 103 • Raleigh, NC 27604 • Phone (919) 876-0405 • Fax (919) 876-0460 • www.geotechnics.net MOISTURE - DENSITY RELATIONSHIP ASTM D698-12 Client:CDM SMITH, INC.Boring No.: STOCKPILE Client Reference: DARE COUNTY C&D LF Depth (ft): NA Project No.:2015-775-001 Sample No.: S Lab ID:2015-775-001-002 Visual Description: BROWN GRAY SANDY LEAN CLAY Total Weight of the Sample (g) 22950 Test Type STANDARD As Received Water Content (%) NA Rammer Weight (lb)5.5 Assumed Specific Gravity 2.70 Rammer Drop (in)12 Rammer Type MECHANICAL Percent Retained on 3/4" NA Machine ID R 174 Percent Retained on 3/8" NA Mold ID R 461 Percent Retained on #4 NA Mold diameter 4" Oversize Material Not included Weight of the Mold (g)4163 Procedure Used A Volume of the Mold (cm3)942 Mold / Specimen Point No.123 4 5 Wt. of Mold & Wet Sample (g) 5853 5927 6064 6173 6122 Wt.of Mold (g) 4163 4163 4163 4163 4163 Wt. of Wet Sample (g) 1690 1764 1901 2010 1959 Mold Volume (cm3)942 942 942 942 942 Moisture Content / Density Tare Number 840 838 842 830 310 Wt. of Tare & Wet Sample (g) 684.70 683.20 789.50 721.18 486.70 Wt. of Tare & Dry Sample (g) 661.00 651.30 734.80 664.20 431.10 Wt. of Tare (g)263.10 262.20 256.10 258.90 112.70 Wt. of Water (g)23.70 31.90 54.70 56.98 55.60 Wt. of Dry Sample (g)397.90 389.10 478.70 405.30 318.40 Wet Density (g/cm3)1.79 1.87 2.02 2.13 2.08 Wet Density (pcf) 111.9 116.9 126.0 133.1 129.8 Moisture Content (%) 6.0 8.2 11.4 14.1 17.5 Dry Density (pcf) 105.7 108.0 113.0 116.7 110.5 Zero Air Voids Moisture Content (%)16.0 19.0 23.0 Dry Unit Weight (pcf)117.7 111.4 103.9 Tested By AF Date 11/17/15 Checked By GEM Date 11/18/15 page 2 of 2 DCN:CT-S12 DATE:5/1/13 REVISION: 14 PROCTOR.xls 2200 Westinghouse Blvd., Suite 103 • Raleigh, NC 27604 • Phone (919) 876-0405 • Fax (919) 876-0460 • www.geotechnics.net CONSOLIDATED UNDRAINED TRIAXIAL TEST WITH PORE PRESSURE READINGS ASTM D4767-11 Client:CDM SMITH, INC.Boring No.:STOCKPILE Client Reference: DARE COUNTY C&D LF Depth (ft):N/A Project No.:2015-775-001 Sample No.: S Lab ID:2015-775-001-002 a =0.00 C =0.00 26.2 29.46 Tested By: SFS Date: 12/9/15 Approved By: MPS Date: 12/17/15 page 1 of 12 DCN: CT-S28 DATE: 4/12/13 REVISION: 3 Sigmatriax.xls 0 5 10 15 20 25 0 5 10 15 20 25 30 35 40 Q, ( p s i ) P, (psi) Consolidated Undrained Triaxial Test with Pore Pressure Max. Effec. Stress Ratio Points Failure Envelope Test No. 1 Test No. 2 Test No. 3  2200 Westinghouse Blvd., Suite 103 • Raleigh, NC 27604 • Phone (919) 876-0405 • Fax (919) 876-0460 • www.geotechnics.net MOHR TOTAL STRENGTH ENVELOPE ASTM D4767-11 Client:CDM SMITH, INC.Boring No.:STOCKPILE Client Reference: DARE COUNTY C&D LF Depth (ft):N/A Project No.: 2015-775-001 Sample No.: S Lab ID:2015-775-001-002 Visual Description: DARK GRAY SANDY CLAY (REMOLDED) Failure Based on Maximum Effective Principal Stress Ratio NOTE: GRAPH NOT TO SCALE Tested By:SFS Date:12/9/15 Approved By: MPS Date:12/17/15 page 2 of 12 DCN: CT-S28 DATE: 4/12/13 REVISION: 3 0 5 10 15 20 25 30 35 40 45 0 5 10 15 20 25 30 35 40 45 50  (p s i ) (psi) c = = 2.44 18.18 2200 Westinghouse Blvd., Suite 103 • Raleigh, NC 27604 • Phone (919) 876-0405 • Fax (919) 876-0460 • www.geotechnics.net CONSOLIDATED UNDRAINED TRIAXIAL TEST WITH PORE PRESSURE READINGS ASTM D4767-11 Client:CDM SMITH, INC.Boring No.:STOCKPILE Client Reference: DARE COUNTY C&D LF Depth (ft):N/A Project No.:2015-775-001 Sample No.:S Lab ID:2015-775-001-002 Visual Description: DARK GRAY SANDY CLAY (REMOLDED) Stage No.1 INITIAL SAMPLE DIMENSIONS (in) Test No.1 Length 1: 5.995 Diameter 1: 2.864 PRESSURES (psi)Length 2: 5.995 Diameter 2: 2.864 Length 3: 5.995 Diameter 3: 2.864 Cell Pressure (psi)55.0 Avg. Length:5.995 Avg. Diam.:2.864 Back Pressure (psi)50.0 Eff. Conf. Pressure (psi) 5.0 VOLUME CHANGE Pore Pressure Initial Burette Reading (ml)16.0 Response (%)96 Final Burette Reading (ml)10.0 Final Change (ml)6.0 MAXIMUM OBLIQUITY POINTS Initial Dial Reading (mil)225 P =8.46 Dial Reading After Saturation (mil) 245 Q =5.63 Dial Reading After Consolidation (mil)266 LOAD DEFORMATION PORE PRESSURE (LB) (IN) (PSI) 0.7 0.000 50.0 9.2 0.001 50.0 19.4 0.003 50.3 35.7 0.008 51.2 45.6 0.014 51.7 51.1 0.020 52.058.2 0.029 52.261.2 0.038 52.3 66.2 0.050 52.3 73.3 0.071 52.2 79.1 0.101 52.0 89.9 0.137 51.6 97.4 0.173 51.3 105.9 0.215 50.9 110.3 0.245 50.6 117.1 0.288 50.2 124.2 0.345 49.8 133.8 0.405 49.3 139.3 0.450 49.0 148.3 0.511 48.6 151.9 0.556 48.3 158.9 0.601 48.0 166.9 0.646 47.8 169.1 0.676 47.6 174.7 0.706 47.4 175.6 0.736 47.2 179.7 0.766 47.0 183.7 0.811 46.8 191.1 0.857 46.6 197.2 0.887 46.4 199.0 0.917 46.3 Tested By: SFS Date: 12/9/15 Input Checked By: GEM Date: 12/17/15 page 3 of 12 DCN: CT-S28 DATE: 4/12/13 REVISION: 3 Sigmatriax.xls 2200 Westinghouse Blvd., Suite 103 • Raleigh, NC 27604 • Phone (919) 876-0405 • Fax (919) 876-0460 • www.geotechnics.net CONSOLIDATED UNDRAINED TRIAXIAL TEST WITH PORE PRESSURE READINGS ASTM D4767-11 Client:CDM SMITH, INC.Boring No.:STOCKPILE Client Reference: DARE COUNTY C&D LF Depth (ft):N/A Project No.: 2015-775-001 Sample No.: S Lab ID:2015-775-001-002 Visual Description: DARK GRAY SANDY CLAY (REMOLDED) Effective Confining Pressure (psi)5.0 Stage No.1 Test No 1 INITIAL DIMENSIONS VOLUME CHANGE Initial Sample Length (in) 6.00 Volume After Consolidation (in3)37.87 Initial Sample Diameter (in)2.86 Length After Consolidation (in)5.95 Initial Sample Area (in2)6.44 Area After Consolidation (in2)6.360 Initial Sample Volume (in3)38.62 Strain Deviation U Effective Principle APQ (%) Stress Stress Ratio 0.02 1.34 -0.04 6.38 5.0 1.265 -0.03 5.71 0.67 0.04 2.94 0.24 7.71 4.8 1.616 0.08 6.24 1.47 0.14 5.49 1.19 9.31 3.8 2.439 0.23 6.56 2.75 0.24 7.04 1.69 10.35 3.3 3.126 0.25 6.83 3.52 0.33 7.90 1.99 10.92 3.0 3.624 0.26 6.96 3.950.49 9.00 2.16 11.84 2.8 4.164 0.25 7.34 4.500.64 9.45 2.28 12.17 2.7 4.468 0.25 7.45 4.72 0.85 10.22 2.28 12.94 2.7 4.756 0.23 7.83 5.11 1.20 11.27 2.18 14.09 2.8 4.990 0.20 8.46 5.63 1.70 12.12 1.96 15.16 3.0 4.980 0.17 9.10 6.06 2.30 13.69 1.59 17.11 3.4 5.008 0.12 10.26 6.85 2.91 14.76 1.24 18.53 3.8 4.923 0.09 11.14 7.38 3.62 15.94 0.83 20.12 4.2 4.814 0.05 12.15 7.97 4.12 16.52 0.58 20.94 4.4 4.737 0.04 12.68 8.26 4.84 17.41 0.18 22.24 4.8 4.608 0.01 13.53 8.71 5.79 18.29 -0.25 23.54 5.3 4.478 -0.01 14.40 9.14 6.80 19.50 -0.69 25.19 5.7 4.426 -0.04 15.44 9.75 7.56 20.14 -1.06 26.20 6.1 4.322 -0.05 16.13 10.07 8.58 21.22 -1.48 27.70 6.5 4.274 -0.07 17.09 10.61 9.33 21.56 -1.73 28.29 6.7 4.201 -0.08 17.51 10.78 10.09 22.35 -1.99 29.35 7.0 4.195 -0.09 18.17 11.18 10.85 23.30 -2.27 30.57 7.3 4.203 -0.10 18.92 11.65 11.35 23.47 -2.47 30.94 7.5 4.141 -0.11 19.21 11.74 11.85 24.12 -2.66 31.78 7.7 4.146 -0.11 19.72 12.06 12.36 24.10 -2.83 31.93 7.8 4.078 -0.12 19.88 12.05 12.87 24.52 -3.05 32.58 8.1 4.045 -0.13 20.32 12.26 13.62 24.85 -3.26 33.11 8.3 4.008 -0.14 20.68 12.42 14.40 25.62 -3.47 34.09 8.5 4.024 -0.14 21.28 12.81 14.89 26.29 -3.66 34.96 8.7 4.033 -0.15 21.81 13.14 15.41 26.37 -3.78 35.15 8.8 4.001 -0.15 21.97 13.18 page 4 of 12 2200 Westinghouse Blvd., Suite 103 • Raleigh, NC 27604 • Phone (919) 876-0405 • Fax (919) 876-0460 • www.geotechnics.net CONSOLIDATED UNDRAINED TRIAXIAL TEST WITH PORE PRESSURE READINGS ASTM D4767-11 Client:CDM SMITH, INC.Boring No.:STOCKPILE Client Reference: DARE COUNTY C&D LF Depth (ft):N/A Project No.:2015-775-001 Sample No.:S Lab ID:2015-775-001-002 Visual Description: DARK GRAY SANDY CLAY (REMOLDED) Stage No.1 INITIAL SAMPLE DIMENSIONS (in) Test No.2 Length 1: 5.995 Diameter 1: 2.864 PRESSURES (psi)Length 2: 5.995 Diameter 2: 2.864Length 3: 5.995 Diameter 3: 2.864 Cell Pressure (psi)60.0 Avg. Length 5.995 Avg. Diam.:2.864 Back Pressure (psi)50.0 Eff. Conf. Pressure (psi) 10.0 VOLUME CHANGE Pore Pressure Initial Burette Reading (ml)24.0 Response (%)97 Final Burette Reading (ml)4.2 Final Change (ml)19.8 MAXIMUM OBLIQUITY POINTS Initial Dial Reading (mil)144 P =13.06 Dial Reading After Saturation (mil)159 Q =7.90 Dial Reading After Consolidation (mil)197 LOAD DEFORMATION PORE PRESSURE (LB)(IN)(PSI) 10.5 0.000 50.017.8 0.000 50.1 25.6 0.001 50.4 50.6 0.007 52.060.8 0.013 53.167.2 0.018 53.7 74.7 0.027 54.380.4 0.036 54.786.2 0.049 55.0 94.0 0.069 55.2 100.5 0.100 55.2106.3 0.135 55.0 112.1 0.171 54.8 116.9 0.213 54.6120.4 0.244 54.4 126.5 0.286 54.1 133.3 0.343 53.7139.1 0.403 53.4 143.5 0.447 53.1 149.7 0.507 52.8154.9 0.553 52.6 159.1 0.598 52.4 162.9 0.643 52.2165.8 0.672 52.0 168.7 0.703 51.9 171.2 0.732 51.8174.1 0.763 51.6 177.9 0.808 51.4 182.1 0.853 51.3184.4 0.883 51.1186.7 0.913 51.0 Tested By: SFS Date: 12/9/15 Input Checked By: GEM Date: 12/17/15 page 5 of 12 DCN: CT-S28 DATE: 4/12/13 REVISION: 3 2200 Westinghouse Blvd., Suite 103 • Raleigh, NC 27604 • Phone (919) 876-0405 • Fax (919) 876-0460 • www.geotechnics.net CONSOLIDATED UNDRAINED TRIAXIAL TEST WITH PORE PRESSURE READINGS ASTM D4767-11 Client:CDM SMITH, INC.Boring No.:STOCKPILE Client Reference: DARE COUNTY C&D LF Depth (ft):N/A Project No.: 2015-775-001 Sample No.: S Lab ID:2015-775-001-002 Visual Description: DARK GRAY SANDY CLAY (REMOLDED) Effective Confining Pressure (psi)10.0 Stage No.1 Test No 2 INITIAL DIMENSIONS VOLUME CHANGE Initial Sample Length (in)6.00 Volume After Consolidation (in3)37.12 Initial Sample Diameter (in)2.86 Length After Consolidation (in)5.94 Initial Sample Area (in2)6.44 Area After Consolidation (in2)6.248 Initial Sample Volume (in3)38.62 Strain Deviation U Effective Principle A PQ (%) Stress Stress Ratio 0.00 1.16 0.12 11.03 9.9 1.118 0.11 10.45 0.58 0.01 2.42 0.42 11.99 9.6 1.253 0.18 10.78 1.21 0.12 6.41 2.03 14.36 8.0 1.805 0.33 11.16 3.200.21 8.04 3.06 14.97 6.9 2.160 0.39 10.95 4.020.31 9.05 3.70 15.34 6.3 2.439 0.42 10.81 4.53 0.45 10.23 4.31 15.91 5.7 2.802 0.43 10.79 5.11 0.61 11.12 4.68 16.42 5.3 3.094 0.43 10.87 5.560.82 12.02 4.97 17.04 5.0 3.394 0.43 11.03 6.01 1.17 13.21 5.19 18.01 4.8 3.750 0.40 11.41 6.60 1.68 14.16 5.19 18.96 4.8 3.953 0.38 11.88 7.082.28 14.98 5.04 19.93 4.9 4.029 0.35 12.44 7.49 2.88 15.79 4.83 20.95 5.2 4.060 0.32 13.06 7.90 3.59 16.42 4.56 21.84 5.4 4.024 0.29 13.64 8.214.10 16.87 4.35 22.51 5.6 3.991 0.27 14.08 8.44 4.81 17.68 4.07 23.60 5.9 3.986 0.24 14.76 8.84 5.77 18.52 3.71 24.80 6.3 3.951 0.21 15.54 9.266.78 19.19 3.36 25.82 6.6 3.896 0.18 16.23 9.60 7.53 19.68 3.11 26.56 6.9 3.862 0.16 16.72 9.84 8.54 20.38 2.80 27.57 7.2 3.835 0.14 17.38 10.199.31 20.96 2.57 28.38 7.4 3.825 0.13 17.90 10.48 10.06 21.39 2.35 29.02 7.6 3.801 0.11 18.33 10.69 10.82 21.76 2.15 29.60 7.8 3.776 0.10 18.72 10.8811.32 22.05 2.02 30.02 8.0 3.769 0.09 18.99 11.03 11.83 22.33 1.88 30.44 8.1 3.755 0.09 19.27 11.17 12.32 22.56 1.76 30.79 8.2 3.740 0.08 19.51 11.2812.84 22.83 1.63 31.19 8.4 3.732 0.07 19.77 11.41 13.60 23.16 1.44 31.70 8.5 3.709 0.06 20.12 11.58 14.36 23.53 1.26 32.25 8.7 3.696 0.06 20.49 11.7614.86 23.70 1.14 32.54 8.8 3.679 0.05 20.69 11.8515.36 23.87 1.04 32.83 9.0 3.666 0.04 20.89 11.94 page 6 of 12 2200 Westinghouse Blvd., Suite 103 • Raleigh, NC 27604 • Phone (919) 876-0405 • Fax (919) 876-0460 • www.geotechnics.net CONSOLIDATED UNDRAINED TRIAXIAL TEST WITH PORE PRESSURE READINGS ASTM D4767-11 Client:CDM SMITH, INC.Boring No.:STOCKPILE Client Reference: DARE COUNTY C&D LF Depth (ft):N/A Project No.:2015-775-001 Sample No.:S Lab ID:2015-775-001-002 Visual Description: DARK GRAY SANDY CLAY (REMOLDED) Stage No.1 INITIAL SAMPLE DIMENSIONS (in) Test No.3 Length 1: 5.995 Diameter 1: 2.864 PRESSURES (psi)Length 2: 5.995 Diameter 2: 2.864Length 3: 5.995 Diameter 3: 2.864 Cell Pressure (psi)65.0 Avg. Length:5.995 Avg. Diam.:2.864 Back Pressure (psi)50.0 Eff. Conf. Pressure (psi) 15.0 VOLUME CHANGE Pore Pressure Initial Burette Reading (ml)38.0 Response (%)95 Final Burette Reading (ml)17.9 Final Change (ml)20.1 MAXIMUM OBLIQUITY POINTS Initial Dial Reading (mil)186 P =21.94 Dial Reading After Saturation (mil)174 Q =12.71 Dial Reading After Consolidation (mil)212 LOAD DEFORMATION PORE PRESSURE (LB)(IN)(PSI) 11.4 0.000 50.077.5 0.014 53.7105.4 0.028 55.8123.4 0.043 56.5 135.3 0.058 56.8 143.1 0.073 56.9 148.5 0.087 56.8153.0 0.102 56.8156.8 0.117 56.7160.3 0.132 56.6 163.4 0.147 56.4 166.3 0.162 56.3 169.2 0.176 56.2 172.0 0.191 56.1177.9 0.221 55.8182.8 0.252 55.6 187.1 0.282 55.3 191.2 0.311 55.1 195.2 0.341 54.9 199.3 0.370 54.7203.9 0.400 54.5208.1 0.431 54.3211.3 0.461 54.1 214.7 0.491 53.9 218.2 0.520 53.7 222.0 0.550 53.5225.9 0.579 53.4234.2 0.655 53.0247.2 0.772 52.3 260.1 0.894 51.8 265.1 0.952 51.5 Tested By: SFS Date: 12/9/15 Input Checked By: GEM Date: 12/17/15 page 7 of 12 DCN: CT-S28 DATE: 4/12/13 REVISION: 3 2200 Westinghouse Blvd., Suite 103 • Raleigh, NC 27604 • Phone (919) 876-0405 • Fax (919) 876-0460 • www.geotechnics.net CONSOLIDATED UNDRAINED TRIAXIAL TEST WITH PORE PRESSURE READINGS ASTM D4767-11 Client:CDM SMITH, INC.Boring No.:STOCKPILE Client Reference: DARE COUNTY C&D LF Depth (ft):N/A Project No.: 2015-775-001 Sample No.: S Lab ID:2015-775-001-002 Visual Description: DARK GRAY SANDY CLAY (REMOLDED) Effective Confining Pressure (psi)15.0 Stage No.1 Test No 3 INITIAL DIMENSIONS VOLUME CHANGE Initial Sample Length (in) 6.00 Volume After Consolidation (in 3)37.63 Initial Sample Diameter (in)2.86 Length After Consolidation (in)5.97 Initial Sample Area (in2)6.44 Area After Consolidation (in2)6.304 Initial Sample Volume (in3)38.62 Strain Deviation U Effective Principle A PQ (%) Stress Stress Ratio 0.23 10.46 3.71 21.79 11.3 1.923 0.37 16.56 5.230.47 14.84 5.79 24.09 9.2 2.605 0.41 16.67 7.420.72 17.63 6.55 26.12 8.5 3.077 0.39 17.30 8.82 0.97 19.46 6.81 27.69 8.2 3.364 0.37 17.96 9.73 1.21 20.63 6.87 28.80 8.2 3.526 0.35 18.48 10.32 1.46 21.42 6.85 29.61 8.2 3.617 0.34 18.90 10.711.71 22.08 6.79 30.33 8.2 3.678 0.32 19.29 11.041.96 22.62 6.70 30.96 8.3 3.711 0.31 19.65 11.312.21 23.10 6.58 31.57 8.5 3.730 0.30 20.01 11.55 2.46 23.51 6.46 32.08 8.6 3.741 0.29 20.33 11.75 2.71 23.91 6.33 32.61 8.7 3.746 0.28 20.66 11.95 2.94 24.28 6.21 33.11 8.8 3.752 0.27 20.97 12.14 3.19 24.66 6.09 33.62 9.0 3.754 0.26 21.28 12.333.71 25.43 5.82 34.65 9.2 3.757 0.24 21.94 12.714.22 26.03 5.57 35.50 9.5 3.750 0.23 22.48 13.02 4.72 26.55 5.34 36.24 9.7 3.737 0.21 22.97 13.27 5.22 27.03 5.10 36.97 9.9 3.720 0.20 23.45 13.51 5.71 27.49 4.90 37.64 10.1 3.711 0.19 23.89 13.75 6.19 27.95 4.68 38.32 10.4 3.697 0.18 24.34 13.986.70 28.48 4.49 39.03 10.5 3.700 0.17 24.79 14.247.21 28.95 4.29 39.71 10.8 3.692 0.16 25.23 14.487.72 29.26 4.09 40.21 11.0 3.672 0.15 25.58 14.63 8.22 29.59 3.91 40.73 11.1 3.658 0.14 25.93 14.80 8.71 29.94 3.73 41.25 11.3 3.647 0.13 26.28 14.97 9.21 30.33 3.55 41.82 11.5 3.640 0.12 26.65 15.169.69 30.73 3.38 42.39 11.7 3.635 0.12 27.02 15.3610.97 31.46 2.97 43.53 12.1 3.607 0.10 27.80 15.7312.94 32.57 2.36 45.25 12.7 3.568 0.08 28.97 16.28 14.97 33.54 1.80 46.77 13.2 3.534 0.06 30.01 16.77 15.95 33.83 1.53 47.33 13.5 3.505 0.05 30.42 16.91 page 8 of 12 2200 Westinghouse Blvd., Suite 103 • Raleigh, NC 27604 • Phone (919) 876-0405 • Fax (919) 876-0460 • www.geotechnics.net CONSOLIDATED UNDRAINED TRIAXIAL TEST WITH PORE PRESSURE READINGS ASTM D4767-11 Client:CDM SMITH, INC.Boring No.:STOCKPILE Client Reference:DARE COUNTY C&D LF Depth (ft):N/A Project No.:2015-775-001 Sample No.:S Lab ID:2015-775-001-002 Visual Description: DARK GRAY SANDY CLAY (REMOLDED) Tested By: SFS Date: 12/9/15 Approved By: MPS Date: 12/17/15 page 9 of 12 0 5 10 15 20 25 30 35 40 024681012141618 De v i a t o r S t r e s s ( p s i ) Strain (%) Test No. 1 Test No. 2 Test No. 3 2200 Westinghouse Blvd., Suite 103 • Raleigh, NC 27604 • Phone (919) 876-0405 • Fax (919) 876-0460 • www.geotechnics.net CONSOLIDATED UNDRAINED TRIAXIAL TEST WITH PORE PRESSURE READINGS ASTM D4767-11 Client:CDM SMITH, INC. Client Reference: DARE COUNTY C&D LF Project No.: 2015-775-001 Lab ID:2015-775-001-002 Specific Gravity (assumed)2.7 Visual Description: DARK GRAY SANDY CLAY (REMOLDED) SAMPLE CONDITION SUMMARY Boring No.:STOCKPILE STOCKPILE STOCKPILE Depth (ft): N/A N/A N/A Sample No.: S S S Test No. T1 T2 T3 Deformation Rate (in/min) 0.001 0.001 0.001 Back Pressure (psi) 50.0 50.0 50.0 Consolidation Time (days) 1 1 1 Moisture Content (%) (INITIAL) 14.1 14.1 14.1 Total Unit Weight (pcf) 128.9 128.9 129.8 Dry Unit Weight (pcf) 113.0 113.0 113.8 Moisture Content (%) (FINAL) 17.6 18.3 17.8 Initial State Void Ratio,e 0.492 0.492 0.481 Void Ratio at Shear, e 0.463 0.434 0.443 Tested By:SFS Date: 12/9/15 Input Checked By: GEM Date: 12/17/15 page 10 of 12 DCN: CT-S28 DATE: 4/12/13 REVISION: 3 2200 Westinghouse Blvd., Suite 103 • Raleigh, NC 27604 • Phone (919) 876-0405 • Fax (919) 876-0460 • www.geotechnics.net CONSOLIDATED UNDRAINED TRIAXIAL TEST WITH PORE PRESSURE READINGS ASTM D4767-11 MOISTURE CONTENT T1 T2 T3 Tare Number 800 800 800 Weight of Tare & Wet Sample (g)426.52 426.52 426.52 Weight of Tare & Dry Sample (g)386.52 386.52 386.52 Weight of Tare (g)103.10 103.10 103.10 Moisture Content (%) (INITIAL)14.11 14.11 14.11 Tare Number 806 823 825 Weight of Tare & Wet Sample (g)767.00 818.31 850.75 Weight of Tare & Dry Sample (g)667.00 712.26 742.89 Weight of Tare (g)100.01 133.96 137.30 Moisture Content (%) (FINAL)17.64 18.34 17.81 UNIT WEIGHT Weight of Tube & Wet Sample (g)1306.87 1307.02 1316.12 Weight of Tube (g)0.00 0.00 0.00 Weight of Wet Sample (g)1306.87 1307.02 1316.12 Length 1 (in)5.995 5.995 5.995 Length 2 (in)5.995 5.995 5.995 Length 3 (in)5.995 5.995 5.995 Top Diameter (in)2.864 2.864 2.864 Middle Diameter (in)2.864 2.864 2.864 Bottom Diameter (in)2.864 2.864 2.864 Average Length (in)5.995 5.995 5.995 Average Area (in)6.442 6.442 6.442 Sample Volume (cm3)632.89 632.89 632.89 Unit Wet Weight (g/cm 3)2.06 2.07 2.08 Unit Wet Weight (pcf)128.91 128.93 129.83 Unit Dry Weight (pcf)112.97 112.98 113.77 Unit Dry Weight (g/cm3)1.81 1.81 1.82 Initial Burette Reading 16 24 38 Final Burette Reading 10 4.2 17.9 Initial Dial Reading 225 144 186 Dial Reading After Saturation 245 159 174 Dial Reading After Consolidation 266 197 212 Volume Change during Consolidation 6 19.8 20.1 Volume Change during Saturation 6.33 4.75 -3.80 Volume at Shear (cm3)*These 620.55 608.34 616.59 Volume of Solids (cm3) measurements 424.16 424.21 427.16 Volume of Voids (cm3)are all 196.39 184.13 189.42 Volume of Water (cm 3) at 201.99 210.04 205.42 Void Ratio, e shear 0.463 0.434 0.443 page 11 of 12 DCN: CT-S28 DATE: 4/12/13 REVISION: 3 2200 Westinghouse Blvd., Suite 103 • Raleigh, NC 27604 • Phone (919) 876-0405 • Fax (919) 876-0460 • www.geotechnics.net CONSOLIDATED UNDRAINED TRIAXIAL TEST WITH PORE PRESSURE READINGS ASTM D4767-11 Client: CDM SMITH, INC. Boring No.: STOCKPILE Client Reference: DARE COUNTY C&D LF Depth (ft): N/A Project No.: 2015-775-001 Sample No.: S Lab ID: 2015-775-001-002 TEST 1 INITIAL TEST 1 FINAL TEST 2 INITIAL TEST 2 FINAL TEST 3 INITIAL TEST 3 FINAL Tested By SFS Date 12/9/15 Approved By MPS Date 12/17/15 page 12 of 12 DCN: CT-S28 DATE: 4/12/13 REVISION: 3 C:\Users\GEOLAPTOP-3\Desktop\work\[2015-775-001-002 SIGMATRIAX.xlsm]SUMMARY N/A N/A N/A GET Solutions Inspection Reports Daily Field Report Virginia Beach Office Williamsburg Office Elizabeth City Office 204 Grayson Rd 1592 Penniman Rd Suite E 106 Capital Trace, Unit E Virginia Beach, VA 23462 Williamsburg, VA 23185 Elizabeth City, NC 27909 1 of 1 757-518-1703 phone 757-564-6452 phone 252-335-9765 phone 757-518-1704 fax 757-564-6453 fax 252-335-9766 fax x Project Name: Project Location:Bldg Permit #: Project No: Geo-Report No:Report unavailable/ GEO not performed Contractor: Plans Date:DWG #'s:DWG detail #'s: Footing Observations:DCP Other: Ftg Width: Ftg Depth: Are the recovered soils consistent with the geotech report?Yes No (see remarks below)Report unavailable/not performed Is the observed area approved for the placement of concrete?Yes No (see remarks below) Reinforcing Steel Observations: General Location: Specific Location: Placement Details: (if marked No - see remarks below) Y N N/A Y N N/A Y N N/A Keyway req'd/observed?Vapor Barrier per spec?Rebar per spec? Formwork per spec?Wire Mesh per spec?Splices per spec? Exp. Joints per spec?Add In Bars per spec?Clearances per spec? Subgrade Evaluations: According to the contractor the observed area is:at grade elevation with 3'req'd to reach design grade Proofroll equipment used: Deflections observed beneath the applied wheel loads: (check all that apply) 1.5 Test Pits:how many? 4 depth?3 Visual Classification of soils: Are the recovered soils consistent with the geotech report?Yes No (see remarks)Report unavailable/not performed Remarks / Recommendations:(check all that apply)Area observed noted suitable for next phase Deficiency / Discrepancy General contractor notified Structural Engineer Notified General Contractor Representative:GET Solutions, Inc. Representative: Sign Sign Print Print RPC Contracting, Inc. Page inches Dare County Landfill - Phase V Dare County, NC Roller Date: Client: 7/11/2016 HA RPC Contracting, Inc.EC16-217T how many/depth: Project Plan Information:(cross reference arch w/ struct for coordination) General Location: Visual Classification: at design grade From South End, approximately 300' North As requested a representative of GET solutions, Inc. arrived onsite to perform a subgrade evaluation for the area noted above. A proofroll was perormed on the East and West shoulders (sides) of the existing ditch using a vibratory roller. Deflections beneath applied wheel loads were observed to be less than 1.5". Given amount of fill required to establish FG (3' according to contractor), sufficient bridging from the fill is anticipated over healing subgrade. The base of the excavated area contained approximately 8" to 10" of water. Area will require further mucking and or removal of water to properly evaluate. Contractor was notified. Project specifications indicate lifts must not exceed 8". Given water table depth, a bridge lift may be needed to provide stability and sufficiant compaction. However material being used as backfill contains significant amounts of fines (Clay and Silt) and is not recommended to be used as bridge lift material. Location: inches Tan- Grey SAND; Sun underlain by mixture of Grey Cley, Tan CLAY some organic, Grey-Tan SAND J. Meads Please note the results of this date's observations are pending review by a GET Solutions, Inc. Professional Engineer (attach Paperwork)explain (see remarks below) less than sponging other (explain) Footing Slab Wall (CMU)Wall (formed)Wall (tilt up) Other (explain): Column (formed) more than rutting pumping Daily Field Report Virginia Beach Office Williamsburg Office Elizabeth City Office 204 Grayson Rd 1592 Penniman Rd Suite E 106 Capital Trace, Unit E Virginia Beach, VA 23462 Williamsburg, VA 23185 Elizabeth City, NC 27909 1 of 1 757-518-1703 phone 757-564-6452 phone 252-335-9765 phone 757-518-1704 fax 757-564-6453 fax 252-335-9766 fax x Project Name: Project Location:Bldg Permit #: Project No: Geo-Report No:Report unavailable/ GEO not performed Contractor: Plans Date:DWG #'s:DWG detail #'s: Footing Observations:DCP Other: Ftg Width: Ftg Depth: Are the recovered soils consistent with the geotech report?Yes No (see remarks below)Report unavailable/not performed Is the observed area approved for the placement of concrete?Yes No (see remarks below) Reinforcing Steel Observations: General Location: Specific Location: Placement Details: (if marked No - see remarks below) Y N N/A Y N N/A Y N N/A Keyway req'd/observed?Vapor Barrier per spec?Rebar per spec? Formwork per spec?Wire Mesh per spec?Splices per spec? Exp. Joints per spec?Add In Bars per spec?Clearances per spec? Subgrade Evaluations: According to the contractor the observed area is:at grade elevation with 3'req'd to reach design grade Proofroll equipment used: Deflections observed beneath the applied wheel loads: (check all that apply) Test Pits:how many? 4 1.5 depth?4 Visual Classification of soils: Are the recovered soils consistent with the geotech report?Yes No (see remarks)Report unavailable/not performed Remarks / Recommendations:(check all that apply)Area observed noted suitable for next phase Deficiency / Discrepancy General contractor notified Structural Engineer Notified General Contractor Representative:GET Solutions, Inc. Representative: Sign Sign Print Print Page inches Dare County Landfill - Phase V Dare County, NC Vibrator Roller Date: Client: 7/21/2016 HA RPC Contracting, Inc. RPC Contracting, Inc.EC16-217T how many/depth: Project Plan Information:(cross reference arch w/ struct for coordination) General Location: Visual Classification: at design grade East and West Shoulder/Sides of ditch; 250' to 1100' North of South endLocation: inches Tan- Grey mottled CLAY underlain by Gray-Tan clayey SAND J. Meads Please note the results of this date's observations are pending review by a GET Solutions, Inc. Professional Engineer As requested a representative of GET solutions, Inc. arrived onsite to perform a subgrade evaluation for the area noted above. A vibratory roller was used to proofroll the exposed subgrade. Approximately 1" to 1.5" of deflection was noted. According to contractor, approximately 2' to 3' of fill is required to establish FG. Fill depth is anticipated to provide sufficient bridging over healing subgrade. (attach Paperwork)explain (see remarks below) less than sponging other (explain) Footing Slab Wall (CMU)Wall (formed)Wall (tilt up) Other (explain): Column (formed) more than rutting pumping Daily Field Report Virginia Beach Office Williamsburg Office Elizabeth City Office 204 Grayson Rd 1592 Penniman Rd Suite E 106 Capital Trace, Unit E Virginia Beach, VA 23462 Williamsburg, VA 23185 Elizabeth City, NC 27909 1 of 1 757-518-1703 phone 757-564-6452 phone 252-335-9765 phone 757-518-1704 fax 757-564-6453 fax 252-335-9766 fax x Project Name: Project Location:Bldg Permit #: Project No: Geo-Report No:Report unavailable/ GEO not performed Contractor: Plans Date:DWG #'s:DWG detail #'s: Footing Observations:DCP Other: Ftg Width: Ftg Depth: Are the recovered soils consistent with the geotech report?Yes No (see remarks below)Report unavailable/not performed Is the observed area approved for the placement of concrete?Yes No (see remarks below) Reinforcing Steel Observations: General Location: Specific Location: Placement Details: (if marked No - see remarks below) Y N N/A Y N N/A Y N N/A Keyway req'd/observed?Vapor Barrier per spec?Rebar per spec? Formwork per spec?Wire Mesh per spec?Splices per spec? Exp. Joints per spec?Add In Bars per spec?Clearances per spec? Subgrade Evaluations: According to the contractor the observed area is:at grade elevation with 2'req'd to reach design grade Proofroll equipment used: Deflections observed beneath the applied wheel loads: (check all that apply) HA's:how many? 2 1.0 depth?4 Visual Classification of soils: Are the recovered soils consistent with the geotech report?Yes No (see remarks)Report unavailable/not performed Remarks / Recommendations:(check all that apply)Area observed noted suitable for next phase Deficiency / Discrepancy General contractor notified Structural Engineer Notified General Contractor Representative:GET Solutions, Inc. Representative: Sign Sign Print Print Page inches Dare County Landfill - Phase V Dare County, NC Vibrator Roller Date: Client: 7/26/2016 HA RPC Contracting, Inc. RPC Contracting, Inc.EC16-217T how many/depth: Project Plan Information:(cross reference arch w/ struct for coordination) General Location: Visual Classification: at design grade West Shoulder/Side; from 1100' to 1800' from South endLocation: inches Gray-Tan Sandy CLAY underlain by Grey CLAY J. Meads Please note the results of this date's observations are pending review by a GET Solutions, Inc. Professional Engineer As requested a representative of GET solutions, Inc. arrived onsite to perform a subgrade evaluation for the area noted above. A proofroll was reformed using a vibratory foller. Deflections beneath applied wheel laods were observed to be less than 1". Areas appeared to be firm/stable and suitable for the next phase of work. (attach Paperwork)explain (see remarks below) less than sponging other (explain) Footing Slab Wall (CMU)Wall (formed)Wall (tilt up) Other (explain): Column (formed) more than rutting pumping GET Solutions Compaction and Geotechnical Lab Reports GET Solutions, Inc. 106 Capital Trace Unit E Elizabeth City, NC 27909 Phone: 252-335-9765 Fax: 252-335-9766 1 Project Name:Dare County Landfill Phase V Technician:J. Meads Client's Name:RPC Contracting, Inc.Job No.:EC16-217T Contractor:RPC Contracting, Inc.Date:7-13-16 Weather :Overcast/80’s W/O # Time:AM A. Description of Work: - Compaction Test B. Location of Inspections : - Ditch Backfill; from South end, approximately 200’ North. - Elevation – 1.00 to 2.00 C. Tests/Observations Performed: FDT D. Problems/Non-Compliances/Failing Tests: E. Remarks or Comments: As requested, a representative of GET Solutions, Inc. arrived onsite to test compaction of the onsite stockpile material (Dark gray silty sand CLAY) used as fill within the above noted area. The nuclear method (ASTM D6938) was used to test compaction of the material. Based on the results of our field and laboratory testing procedures, the in place fill material was noted to have been compacted to at least 95% of the materials maximum dry density as determined by the Standard Proctor (ASTM D698). Distribution:Reviewed by: GET Solutions, Inc. Daily Field Report Project: Project Location: Client: General Contractor:Temp. (˚F)80's Grading Contractor: Spec Actual 1 14.0 131.4 1 95 99 X 2 14.7 132.7 1 95 99 X 3 13.1 131.4 1 95 100 X 4 14.6 131.8 1 95 99 X 5 12.7 133.3 1 95 100 X 6 14.2 131.9 1 95 99 X Compaction Equipment Used:Proctor Number:1 Field Testing Procedure:Proctor Type: Field Testing Method:x Method A Depth:inches Material Description: Method B Depth: Backscatter Max. Dry Density (pcf): 116.4 Optimum Moisture (%): 15.1 Moisture:640 Density: 2247 Make:Model: Troxler 3430 Remarks: Dry Density (pcf) 115.3 115.7 116.2 115.0 118.3 115.5 Vibratory Roller ASTM D 6938 From South end, approximately 195' North General Test Location: -1' MSL -2' MSL -1' MSL From South end, approximately 195' North From South end, approximately 100' North From South end, approximatley 100' North RPC Contracting, Inc. EC16-217T Ditch Backfill Overcast Stumpy Point J. Meads Weather: Job Number: Technician: RPC Contracting, Inc. RPC Contracting, Inc. COMPACTION TEST REPORT 7/13/16Date: PAGE 1 OF 1 Dare County Landfill Phase V G E T Solutions, Inc. 106 Capital Trace; Unit E Elizabeth City, North Carolina 27909 Tel: (252) 335-9765 Fax:(252) 335-9766 Test Number Moisture (%) % Proctor Test Location (Grid, Coordinates, Roadway Station, etc.)Pass Fail Test Elevation* Proctor Number Wet Density (pcf) -2' MSL -1' MSL -2' MSL From South end, approximatley 32' North From South end, approximatley 32' North ASTM D 698 Dark Gray CLAY Test locations and test elevations are approximate and are established in the field by the GET Solutions, Inc. technician. * Note: BFF = Below Finish Floor, BFG = Below Finish Grade, FG = Finished Grade Gauge Standardization Counts:Gauge Identification: Serial #: 32867 GET Solutions, Inc. 106 Capital Trace Unit E Elizabeth City, NC 27909 Phone: 252-335-9765 Fax: 252-335-9766 1 Project Name:Dare County Landfill Phase V Technician:J. Meads Client's Name:RPC Contracting, Inc.Job No.:EC16-217T Contractor:RPC Contracting, Inc.Date:7-15-16 Weather :Clear/90’s W/O # Time:AM A. Description of Work: - Compaction Test B. Location of Inspections : - Ditch Backfill; from South end, approximately 250’ North. - Elevation – 0.00 to 4.00 C. Tests/Observations Performed: FDT D. Problems/Non-Compliances/Failing Tests: E. Remarks or Comments: As requested, a representative of GET Solutions, Inc. arrived onsite to test compaction of the onsite stockpile material (Dark gray silty, clayey SAND) used as fill within the above noted area. The nuclear method (ASTM D6938) was used to test compaction of the material. Based on the results of our field and laboratory testing procedures, the in place fill material was noted to have been compacted to at least 95% of the materials maximum dry density as determined by the Standard Proctor (ASTM D698). Distribution:Reviewed by: GET Solutions, Inc. Daily Field Report Project: Project Location: Client: General Contractor:Temp. (˚F)90's Grading Contractor: Spec Actual 1 9.0 128.8 2 95 97 x 2 9.7 128.9 2 95 97 x 3 10.7 130.6 2 95 97 x 4 10.9.130.5 2 95 97 x 5 11.5 131.5 2 95 97 x 6 9.7 129.7 2 95 97 x 7 10.0 128.7 2 95 96 x 8 9.5 128.7 2 95 97 x 9 9.7 129.1 2 95 97 x 10 Compaction Equipment Used:Proctor Number:2 Field Testing Procedure:Proctor Type: Field Testing Method:x Method A Depth:12 inches Material Description: Method B Depth: Backscatter Max. Dry Density (pcf): 121.5 Optimum Moisture (%): 11.8 Moisture:Density:Make:Model: Troxler 3430 Remarks: ASTM D 698 Dark Gray SAND Test locations and test elevations are approximate and are established in the field by the GET Solutions, Inc. technician. * Note: BFF = Below Finish Floor, BFG = Below Finish Grade, FG = Finished Grade Gauge Standardization Counts:Gauge Identification: Serial #: 32867 From South end, approximately 150' North 1' MSL 0' MSL 1' MSL 2' MSL From South end, approximately 150' North From South end, approximately 150' North Test Number Moisture (%) % Proctor Test Location (Grid, Coordinates, Roadway Station, etc.)Pass Fail Test Elevation* Proctor Number Wet Density (pcf) RPC Contracting, Inc. COMPACTION TEST REPORT 7/15/16Date: PAGE 1 OF 1 Dare County Landfill Phase V G E T Solutions, Inc. 106 Capital Trace; Unit E Elizabeth City, North Carolina 27909 Tel: (252) 335-9765 Fax:(252) 335-9766 RPC Contracting, Inc. EC16-217T Ditch Backfill Clear Stumpy Point J. Meads Weather: Job Number: Technician: RPC Contracting, Inc. From South end, approximately 150' North General Test Location: 4' MSL 3' MSL 2' MSL From South end, approximately 150' North From South end, approximately 150' North From South end, approximately 150' North 3' MSL From South end, approximately 150' North From South end, approximately 150' North Proctor Data Not Complete 117.7 Vibratory Roller ASTM D 6938 4' MSL Dry Density (pcf) 118.2 117.5 118.0 117.8 117.9 118.2 117.0 117.5 GET Solutions, Inc. 106 Capital Trace Unit E Elizabeth City, NC 27909 Phone: 252-335-9765 Fax: 252-335-9766 1 Project Name:Dare County Landfill Phase V Technician:J. Meads Client's Name:RPC Contracting, Inc.Job No.:EC16-217T Contractor:RPC Contracting, Inc.Date:7-21-16 Weather :Clear/80’s W/O # Time:AM A. Description of Work: - Compaction Test B. Location of Inspections : -Ditch backfill- 350’ to 500’ North of South end C. Tests/Observations Performed: FDT/ Sample Pick up D. Problems/Non-Compliances/Failing Tests: E. Remarks or Comments: As requested, a representative of GET Solutions, Inc. arrived onsite to test compaction of onsite stockpile material (Dark gray silty, Sandy CLAY) used as backfill material for the ditch at areas noted above. The nuclear method (ASTM D6938) was used to test compaction of the material. Based on the results of our field and laboratory testing procedures, the in place fill material was noted to have been compacted to at least 95% of the materials maximum dry density as determined by the Standard Proctor (ASTM D698). Distribution:Reviewed by: GET Solutions, Inc. Daily Field Report Project: Project Location: Client: General Contractor:Temp. (˚F)80's Grading Contractor: Spec Actual 1 13.5 130.0 1 95 98 x 2 14.5 135.5 1 95 99 x 3 15.2 134.2 1 95 100 x 4 15.7 134.2 1 95 100 x 5 13.5 130.2 1 95 98 x 6 12.7 128.5 1 95 98 x 7 13.1 128.4 1 95 97 x 8 12.7 128.3 1 95 98 x 9 10 Compaction Equipment Used:Proctor Number:1 Field Testing Procedure:Proctor Type: Field Testing Method:x Method A Depth:12 inches Material Description: Method B Depth: Backscatter Max. Dry Density (pcf): 116.4 Optimum Moisture (%): 15.1 Moisture:592 Density: 2430 Make:Model: Troxler 3430 Remarks: ASTM D 698 Dark Gray CLAY Test locations and test elevations are approximate and are established in the field by the GET Solutions, Inc. technician. * Note: BFF = Below Finish Floor, BFG = Below Finish Grade, FG = Finished Grade Gauge Standardization Counts:Gauge Identification: Serial #: 31918 From South end, approximately 425' North 1' MSL 0' MSL 1' MSL 2' MSL From South end, approximately 425' North From South end, approximately 425' North Test Number Moisture (%) % Proctor Test Location (Grid, Coordinates, Roadway Station, etc.)Pass Fail Test Elevation* Proctor Number Wet Density (pcf) RPC Contracting Inc COMPACTION TEST REPORT 7/21/16Date: PAGE 1 OF 1 Dare County Landfill Phase V G E T Solutions, Inc. 106 Capital Trace; Unit E Elizabeth City, North Carolina 27909 Tel: (252) 335-9765 Fax:(252) 335-9766 RPC Contracting Inc EC16-217T Ditch Backfill Clear Stumpy Point J. Meads Weather: Job Number: Technician: RPC Contracting Inc From South end, approximately 425' North General Test Location: 4' MSL 3' MSL 2' MSL From South end, approximately 425' North From South end, approximately 425' North From South end, approximately 425' North 3' MSL From South end, approximately 425' North Vibratory Roller ASTM D 6938 Dry Density (pcf) 114.5 115.7 116.5 116.0 114.8 114.0 113.5 113.8 GET Solutions, Inc. 106 Capital Trace Unit E Elizabeth City, NC 27909 Phone: 252-335-9765 Fax: 252-335-9766 1 Project Name:Dare County Landfill Phase V Technician:J. Meads Client's Name:RPC Contracting, Inc.Job No.:EC16-217T Contractor:RPC Contracting, Inc.Date:7-26-16 Weather :Clear/80’s W/O # Time:AM A. Description of Work: - Compaction Test B. Location of Inspections : -Ditch backfill- 500’ to 1200’ North end. (in place since last visit) C. Tests/Observations Performed: FDT/ Sample Pick up (2) D. Problems/Non-Compliances/Failing Tests: E. Remarks or Comments: As requested, a representative of GET Solutions, Inc. arrived onsite to test compaction of the onsite stockpile material (Dark gray silty sandy CLAY) used as backfill material for the ditch at areas noted above. The nuclear method (ASTM D6938) was used to test compaction of the material. Based on the results of our field and laboratory testing procedures, the in place fill material was noted to have been compacted to at least 95% of the materials maximum dry density as determined by the Standard Proctor (ASTM D698). Distribution:Reviewed by: GET Solutions, Inc. Daily Field Report Project: Project Location: Client: General Contractor:Temp. (˚F)90's Grading Contractor: Spec Actual 1 13.5 131.3 1 95 99 X 2 13.9 133.3 1 95 100 X 3 14.0 131.1 1 95 99 X 4 14.3 133.8 1 95 100 X 5 14.0 131.2 1 95 99 X 6 13.1 131.2 1 95 100 X 7 13.5 130.2 1 95 99 X 8 12.7 129.0 1 95 98 X 9 12.9 129.7 1 95 99 X 10 Compaction Equipment Used:Proctor Number:1 Field Testing Procedure:Proctor Type: Field Testing Method:x Method A Depth:12 inches Material Description: Method B Depth: Backscatter Max. Dry Density (pcf): 116.4 Optimum Moisture (%): 15.1 Moisture:709 Density: 2236 Make:Model: Troxler 3430 Remarks: Dry Density (pcf) 115.7 117.0 115.0 117.1 115.1 116.0 114.7 114.5 3' MSL From South end, approximately 1150' North From South end, approximately 1150' North114.9 Vibratory Roller ASTM D 6938 4' MSL From South end, approximately 1150' North General Test Location: 4' MSL 3' MSL 2' MSL From South end, approximately 1150' North From South end, approximately 1150' North From South end, approximately 1150' North RPC Contracting Inc EC16-217T Ditch Backfill Clear Stumpy Point J. Meads Weather: Job Number: Technician: RPC Contracting Inc RPC Contracting Inc COMPACTION TEST REPORT 7/26/16Date: PAGE 1 OF 1 Dare County Landfill Phase V G E T Solutions, Inc. 106 Capital Trace; Unit E Elizabeth City, North Carolina 27909 Tel: (252) 335-9765 Fax:(252) 335-9766 Test Number Moisture (%) % Proctor Test Location (Grid, Coordinates, Roadway Station, etc.)Pass Fail Test Elevation* Proctor Number Wet Density (pcf) From South end, approximately 1150' North 1' MSL 0' MSL 1' MSL 2' MSL From South end, approximately 1150' North From South end, approximately 1150' North ASTM D 698 Dark Gray silty sandy CLAY Test locations and test elevations are approximate and are established in the field by the GET Solutions, Inc. technician. * Note: BFF = Below Finish Floor, BFG = Below Finish Grade, FG = Finished Grade Gauge Standardization Counts:Gauge Identification: Serial #: 32487 Tested By:D. Forehand MOISTURE DENSITY RELATIONSHIP (PROCTOR CURVE) D r y d e n s i t y , p c f 107 112 117 122 127 132 Water content, % 5 7 9 11 13 15 17 11.8%, 121.5 pcf ZAV for Sp.G. = 2.65 Test specification:ASTM D 698-12 Method A Standard SM A-2-4(0)12.1 NV NP 0.6 33.5 Dark Gray Silty SAND w/shell fragments EC16-217T RPC Proctor No. 2 Elev/Classification Nat.Sp.G.LL PI % >% < Depth USCS AASHTO Moist.#4 No.200 TEST RESULTS MATERIAL DESCRIPTION Project No.Client:Remarks: Project: Loc.:Approximately 350' North of South End, Center of Ditch Sample No.:2 GET SOLUTIONS, INC. Elizabeth City, North Carolina Figure Maximum dry density = 121.5 pcf Optimum moisture = 11.8 % Dare County Landfill GET SOLUTIONS, INC. Elizabeth City, North Carolina (no specification provided) PL=LL=PI= D90=D85=D60=D50=D30=D15=D10=Cu=Cc= USCS=AASHTO= * Dark Gray Silty SAND w/shell fragments .375 #4 #8 #10 #16 #30 #40 #50 #60 #80#100 #120 #200 99.7 99.4 98.4 98.2 97.2 94.8 91.8 86.7 75.7 52.848.8 46.3 33.5 NP NV NP 0.3357 0.2890 0.20400.1631 SM A-2-4(0) Proctor No. 2 F.M.=0.75 RPC Dare County Landfill EC16-217T Material Description Atterberg Limits Coefficients Classification Remarks Location:Approximately 350' North of South End, Center of DitchSample Number:2 Date: Client: Project: Project No:Figure SIEVE PERCENT SPEC.*PASS? SIZE FINER PERCENT (X=NO) P E R C E N T F I N E R 0 10 20 30 40 50 60 70 80 90 100 GRAIN SIZE - mm. 0.0010.010.1110100 % +3"Coarse % Gravel Fine Coarse Medium % Sand Fine Silt % Fines Clay 1.2 6.4 58.3 33.5 6 i n . 3 i n . 2 i n . 1 ½ i n . 1 i n . ¾ i n . ½ i n . 3 /8 i n . #4 #1 0 #2 0 #3 0 #4 0 #6 0 #1 0 0 #1 4 0 #2 0 0 Particle Size Distribution Report Tested By:D. Forehand MOISTURE DENSITY RELATIONSHIP (PROCTOR CURVE) D r y d e n s i t y , p c f 113 115 117 119 121 123 Water content, % 6 8 10 12 14 16 18 12.8%, 120.0 pcf ZAV for Sp.G. = 2.62 Test specification:ASTM D 698-12 Method A Standard SM A-2-4(0)9.7 17 2 1.0 34.2 Dark Gray Silty fine SAND w/shell fragments EC16-217T RPC Proctor No. 3 Elev/Classification Nat.Sp.G.LL PI % >% < Depth USCS AASHTO Moist.#4 No.200 TEST RESULTS MATERIAL DESCRIPTION Project No.Client:Remarks: Project: Loc.:Approximately 1150' North of South End, Center of Ditch Sample No.:3 GET SOLUTIONS, INC. Elizabeth City, North Carolina Figure Maximum dry density = 120.0 pcf Optimum moisture = 12.8 % Dare County Landfill GET SOLUTIONS, INC. Elizabeth City, North Carolina (no specification provided) PL=LL=PI= D90=D85=D60=D50=D30=D15=D10=Cu=Cc= USCS=AASHTO= * Dark Gray Silty fine SAND w/shell fragments .5 .375 #4 #8 #10 #16 #30 #40 #50 #60#80 #100 #120 #200 99.5 99.5 99.0 97.6 97.3 96.2 93.4 90.2 85.3 75.855.3 48.6 45.7 34.2 15 17 2 0.4075 0.2974 0.19580.1579 SM A-2-4(0) Proctor No. 3 F.M.=0.80 RPC Dare County Landfill EC16-217T Material Description Atterberg Limits Coefficients Classification Remarks Location:Approximately 1150' North of South End, Center of DitchSample Number:3 Date: Client: Project: Project No:Figure SIEVE PERCENT SPEC.*PASS? SIZE FINER PERCENT (X=NO) P E R C E N T F I N E R 0 10 20 30 40 50 60 70 80 90 100 GRAIN SIZE - mm. 0.0010.010.1110100 % +3"Coarse % Gravel Fine Coarse Medium % Sand Fine Silt % Fines Clay 1.7 7.1 56.0 34.2 6 i n . 3 i n . 2 i n . 1 ½ i n . 1 i n . ¾ i n . ½ i n . 3 /8 i n . #4 #1 0 #2 0 #3 0 #4 0 #6 0 #1 0 0 #1 4 0 #2 0 0 Particle Size Distribution Report Tested By:D. Forehand MOISTURE DENSITY RELATIONSHIP (PROCTOR CURVE) D r y d e n s i t y , p c f 109 111.5 114 116.5 119 121.5 Water content, % 7.5 9 10.5 12 13.5 15 16.5 12.3%, 118.9 pcf ZAV for Sp.G. = 2.65 Test specification:ASTM D 698-12 Method A Standard SC A-6(3)13.1 22 7 1.3 48.1 Dark Gray Clayey SAND with Silt and Marine Shell fragments EC16-217T RPC Proctor No. 4 Elev/Classification Nat.Sp.G.LL PI % >% < Depth USCS AASHTO Moist.#4 No.200 TEST RESULTS MATERIAL DESCRIPTION Project No.Client:Remarks: Project: Location:Approximately 1400' North of South End Sample Number:4 GET SOLUTIONS, INC. Elizabeth City, North Carolina Figure Maximum dry density = 118.9 pcf Optimum moisture = 12.3 % Dare County Landfill GET SOLUTIONS, INC. Elizabeth City, North Carolina (no specification provided) PL=LL=PI= D90=D85=D60=D50=D30=D15=D10=Cu=Cc= USCS=AASHTO= * Dark Gray Clayey SAND with Silt and Marine Shell fragments#4 #8 #10 #16 #30 #40 #50 #60 #80 #100#120 #200 98.7 97.7 97.5 96.7 94.9 92.8 89.4 83.7 69.8 64.861.9 48.1 7 22 7 0.3092 0.2584 0.11360.0795 SC A-6(3) F.M.=0.58 RPC Dare County Landfill EC16-217T Material Description Atterberg Limits Coefficients Classification Remarks Location:Approximately 1400' North of South EndSample Number:4 Date: Client: Project: Project No:Figure SIEVE PERCENT SPEC.*PASS? SIZE FINER PERCENT (X=NO) P E R C E N T F I N E R 0 10 20 30 40 50 60 70 80 90 100 GRAIN SIZE - mm. 0.0010.010.1110100 % +3"Coarse % Gravel Fine Coarse Medium % Sand Fine Silt % Fines Clay 1.2 4.7 44.7 48.1 6 i n . 3 i n . 2 i n . 1 ½ i n . 1 i n . ¾ i n . ½ i n . 3 /8 i n . #4 #1 0 #2 0 #3 0 #4 0 #6 0 #1 0 0 #1 4 0 #2 0 0 Particle Size Distribution Report PROJECT NAME : Dare Co. Landfill PROJECT # : 10029887 SAMPLE # : 2 PROJECT COUNTY : Dare SAMPLE LOC. : Dare Co. Landfill PROJECT STATE : North Carolina SAMPLE DEPTH : Stock Pile LABORATORY # : 263492 DATE TESTED : 8/15/16 SUBMITTED BY : HDR | ICA DATE REPORTED : 8/19/16 SOIL TYPE : TYPE OF SPECIMEN : Bulk 123 123 Height (in) 1.00 1.00 1.00 0.89 0.85 0.82 Area (in2)4.8695 4.87 4.8695 4.8695 4.8695 4.8695 Wet Unit Weight (pcf) 97.5 100.7 100.2 110.2 118.1 121.8 Dry Unit Weight (pcf) 89.7 92.7 93.5 101.4 108.7 113.7 Void Ratio 0.84 0.78 0.77 0.63 0.52 0.45 Degree of Saturation 27% 29% 25% 37% 44% 42% SPECIMEN INFORMATION INITIAL AFTER CONSOLIDATION DIRECT SHEAR TEST (ASTM D 3080-11) 0.00 5.00 10.00 15.00 20.00 25.00 0.000 0.050 0.100 0.150 0.200 0.250 Sh e a r S t r e s s ( p s i ) Horizontal Displacement (in) Specimen No. 1 Specimen No. 2 Specimen No. 3 0.0000 0.0050 0.0100 0.0150 0.0200 0.0250 0.000 0.050 0.100 0.150 0.200 0.250 Ve r t i c a l D i s p l a c e m e n t ( i n ) Horizontal Displacement (in) 1 of 2 PROJECT NAME : Dare Co. Landfill PROJECT # : 10029887 SAMPLE # : 2 PROJECT COUNTY : Dare SAMPLE LOC. : Dare Co. Landfill PROJECT STATE : North Carolina SAMPLE DEPTH : Stock Pile LABORATORY # : 263492 DATE TESTED : 8/15/16 SUBMITTED BY : HDR | ICA DATE REPORTED : 8/19/16 Summary of Results: Specimen 123 Normal Stress (psi) 10.00 20.00 30.00 Maximum Shear Stress (psi) 5.64 13.38 19.61 Phi Angle = 34.9º Cohesion = 0 psi APPROVED BY: DIRECT SHEAR TEST (ASTM D 3080-11) -5.00 0.00 5.00 10.00 15.00 20.00 25.00 0.00 5.00 10.00 15.00 20.00 25.00 30.00 35.00 Sh e a r S t r e s s ( p s i ) Normal Stress (psi) 2 of 2 PROJECT NAME : Dare Co. Landfill PROJECT # : 10029887 SAMPLE # : 3 PROJECT COUNTY : Dare SAMPLE LOC. : Dare Co. Landfill PROJECT STATE : North Carolina SAMPLE DEPTH : Stock Pile LABORATORY # : 263492 DATE TESTED : 8/15/16 SUBMITTED BY : HDR | ICA DATE REPORTED : 8/19/16 SOIL TYPE : TYPE OF SPECIMEN : Bulk 123 123 Height (in) 1.00 1.00 1.00 0.90 0.88 0.86 Area (in2)4.8695 4.87 4.8695 4.8695 4.8695 4.8695 Wet Unit Weight (pcf) 98.6 98.6 98.7 109.5 112.3 115.4 Dry Unit Weight (pcf) 90.4 90.4 90.4 100.4 103.0 105.7 Void Ratio 0.83 0.83 0.83 0.65 0.61 0.56 Degree of Saturation 29% 29% 29% 37% 39% 43% SPECIMEN INFORMATION INITIAL AFTER CONSOLIDATION DIRECT SHEAR TEST (ASTM D 3080-11) 0.00 5.00 10.00 15.00 20.00 25.00 0.000 0.050 0.100 0.150 0.200 0.250 Sh e a r S t r e s s ( p s i ) Horizontal Displacement (in) Specimen No. 1 Specimen No. 2 Specimen No. 3 0.0000 0.0050 0.0100 0.0150 0.0200 0.0250 0.0300 0.0350 0.000 0.050 0.100 0.150 0.200 0.250 Ve r t i c a l D i s p l a c e m e n t ( i n ) Horizontal Displacement (in) 1 of 2 PROJECT NAME : Dare Co. Landfill PROJECT # : 10029887 SAMPLE # : 3 PROJECT COUNTY : Dare SAMPLE LOC. : Dare Co. Landfill PROJECT STATE : North Carolina SAMPLE DEPTH : Stock Pile LABORATORY # : 263492 DATE TESTED : 8/15/16 SUBMITTED BY : HDR | ICA DATE REPORTED : 8/19/16 Summary of Results: Specimen 123 Normal Stress (psi) 10.00 20.00 30.00 Maximum Shear Stress (psi) 6.29 12.53 19.94 Phi Angle = 34.3º Cohesion = 0 psi APPROVED BY: DIRECT SHEAR TEST (ASTM D 3080-11) -5.00 0.00 5.00 10.00 15.00 20.00 25.00 0.00 5.00 10.00 15.00 20.00 25.00 30.00 35.00 Sh e a r S t r e s s ( p s i ) Normal Stress (psi) 2 of 2 QA Laboratory Compaction Report Appendix B Record Drawing PRELIMINARY PLAT-NOT FOR RECORDATION, CONVEYANCES OR SALES 1 Appendix C Contractor Activity Reports c d m s m i t h . c o m