HomeMy WebLinkAbout3612_DukeAllenRAB_IndusLF_AFR13-14Industrial LF 2014 Page 1 3612-INDUS-2008
Facility Name:Duke Energy - Allen Steam Station RAB Ash Landfill Permit: 3612-INDUS-2008
Physical Address
Street 1: 253 Plant Allen Road
Street 2:
City: Belmont
State:North Carolina Zip: 28012
County: Gaston
Mailing Address
Street 1: 253 Plant Allen Road
Street 2:
City: Belmont
State:North Carolina Zip: 28012
Primary Facility Contact Person
Name: Don Scruggs
Phone: (704) 829-2423 Fax: (704) 829-2385
Email: Don.Scruggs@duke-energy.com
Billing Contact Person
Name: Sean DeNeale
Phone: (704) 382-4731 Fax: (704) 382-6240
Email: Sean.DeNeale@duke-energy.com
1.Tipping Fee: $ 0.00 per Ton (Attach a schedule of tipping fees if appropriate.)
3. Indicate types of disposal activity occurring at this facility (Check all that apply).
Landfilling of industrial waste (specify waste):Bottom Ash, Fly Ash, FGD Clarifier Sludge
Landfilling of construction and demolition waste
Landfilling of asbestos
Landfilling of ash
Landfilling of sludge
Landfilling of other waste (specify):
IND State of North Carolina
Department of Environment and Natural Resources
Division of Waste Management
According to (G.S. 130A-309.09D(b)) completed forms must be returned by August 1, 2014 and a copy of this report must be sent to the
County Manager of each county from which waste was received. If you have questions or require assistance in completing this report, contact
your Regional Environmental Senior Specialist.
INDUSTRIAL WASTE LANDFILL
Facility Annual Report
For the period of July 1, 2013-June 30, 2014
4. What other activities occur at this facility? (check all that apply)
Scrap Tire Collection White Goods Collection Household Hazardous Waste CollectionRecycling/Reuse Collection
If you checked Recycling/Reuse Collection, please indicate the materials accepted: (check all that apply)
Paper Wood Concrete/rubble/asphalt Gypsum/drywall
Cardboard Glass Aluminum Cans Steel Cans
PETE (#1) Plastic HDPE (#2) Plastic Computer Equipment Televisions
Fluorescent lightbulbs Used oil/oil filters Other Metal Other Plastic
Other (specify)Note: Recycling activities occur at the Allen Steam Station but are not associated with the landfill.
Airspace (Capacity): Questions in this section relate to all cells/units of
the facility operated under the current 4-digit permit number
regardless of whether the cells/units are closed or are not contiguous
at the time of this report. Tonnage questions must be based on scale
records and cover the period between the opening date and the date of
the last survey unless another time period is approved. Airspace
measurements include weekly, intermediate and final cover.
5. Date Facility Last Surveyed:4/16/2014
7. Total Tons Disposed in
Airspace Used (tons):932,748.19
6. Airspace Used (cubic yards):829,215
2. Did your facility stop receiving waste during this past Fiscal Year? Yes No
If so, please report the date this occurred:
Industrial LF 2014 Page 3 3612-INDUS-2008
Instructions:
NC DENR
Division of Waste Management - Solid Waste Section Risk Assessment Form
Facility Name: Duke Energy - Allen Steam Station RAB Ash Landfill Permit:3612-INDUS-2008
Address: 253 Plant Allen Road
City: Belmont State: North Carolina Zip: 28012
Date: Jul 24, 2014Person completing Assessment: Sean DeNeale
Phone Number: (704) 382-4761 Fax: (704) 382-6240 Email: Sean.DeNeale@duke-energy.com
Please indicate either Yes or No for each Receptor and Post Closure Maintenance question. Then please
determine the distance or distances for each Receptor from the Edge of Waste (using range finders and/or GIS
maps) and type that information into the form. Please attach additional information including GIS maps, lists of
potable well locations, etc.
Receptors
1. Are there Residential Dwellings Within 1,500 feet of the Edge of Waste?Yes No
If Yes, how many?
What are the three closest distances from the Edge of Waste?Feet Feet Feet
2. Are there Potable Wells Within 1,500 feet of the Edge of Waste?Yes No
If Yes, how many?
What are the three closest distances from the Edge of Waste?Feet Feet Feet
3. Are there Community/Municipal Wells Within 1,500 feet of the Edge of Waste?Yes No
If Yes, how many?
What are the three closest distances from the Edge of Waste?Feet Feet Feet
4. Are there Surface Water Bodies Within 1,500 feet of the Edge of Waste?Yes No
If Yes, how many? 1
What are the three closest distances from the Edge of Waste?Feet290 Feet Feet
Please list the names of the water bodies: Lake Wylie (South Fork of the Catawba River)
5. Is Public Water Available Within 1,500 feet of the Edge of Waste?Yes No
If Yes, how many of the Residential Dwellings noted above are connected?
Corrective Measures
6. Is there an active methane extraction system (blower, flare, etc.)?Yes No
7. Is there a passive methane extraction system (trench, vents in cap, flare, etc.)?Yes No
8. Is there groundwater remediation taking place on site?Yes No
If Yes, what is the specific remedial technology used? UST related groundwater remediation at plant site
Comments
*Waste streams identified on Page 1, Question 3 reflect disposal activities that occurred at this facility from July 1, 2013
through June 30, 2014.
Du
k
e
En
e
r
g
y
– Al
l
e
n
St
e
a
m
St
a
t
i
o
n
RA
B
As
h
La
n
d
f
i
l
l
Pe
r
m
i
t
:
36
1
2
‐IN
D
U
S
‐20
0
8
LEGEND:
Po
t
a
b
l
e
Well Within 1,500’
of
Ed
g
e
of Waste
Su
r
f
a
c
e
Water Bodies
Ed
g
e
of Waste
N
RA
B
As
h
La
n
d
f
i
l
l
Pe
r
m
i
t
No
.
36
1
2
‐IN
D
U
S
‐20
0
8
La
k
e
Wy
l
i
e
(C
a
t
a
w
b
a
Ri
v
e
r
)
526 South Church Street
Charlotte, NC 28202
Mailing Address:
PO Box 1006
Mail Code EC13K
Charlotte, NC 28201-1006
704 382 4761
704 382 6240 fax
July 24, 2014
Mr. Bill Wagner
2090 US Highway 70
Swannanoa, NC 28778
SUBJECT: Duke Energy – Allen Steam Station
Permit Number 3612-INDUS-2008
Industrial Waste Landfill Annual Report
Dear Mr. Wagner:
Attached is the completed Industrial Landfill Annual Report form for Duke Energy’s Allen Steam
Station Retired Ash Basin (RAB) Ash Landfill (Permit No. 36-12) for the past year (7/1/2013 to
6/30/2014).
The landfill only accepts waste from Duke Energy’s Allen Steam Station. A total of approximately
244,329 tons of waste was received by the landfill during the most recent twelve-month period.
Since the landfill went into operation and through the most recent survey on April 16, 2014,
approximately 829,215 cubic yards and 932,748 tons of waste have been disposed in the landfill.
As required by G.S. 130A-309.09D(b), the County Manager for any county that generated waste
for disposal to this landfill must be sent a copy of the Annual Report. Therefore, a copy of this
Annual Report is provided to the County Manager for Gaston County.
If there are any questions regarding this report, please contact me at (704) 382-4761.
Sincerely,
Sean DeNeale, Engineer II
Environmental Services
Attachments
c: Earl Mathers – Gaston County, NC
Don Scruggs – Allen Steam Station