Loading...
HomeMy WebLinkAbout3620_DukeAllen_SSLF_ECMR_FID2822423_20260630(> DUKE ENERGY. June 30, 2026 North Carolina Department of Environmental Quality Division of Waste Management Solid Waste Section 2090 U.S. Highway 70 Swannanoa, NC 28778 Attn: Ms. Sarah Moutos (submitted electronically) Re: Environmental Controls Monitoring Semi -Annual Report South Starter Landfill Permit No.: 3620-INDUS-2022 Allen Steam Station Gaston County, North Carolina Dear Ms. Moutos: 525 S. Tryon St. Mail Code: DEP-36A Charlotte NC, 28202 In accordance with the Environmental Control Monitoring Plan (ECMP) Revision 2, Duke Energy is providing the results of the 2026 first semi-annual leachate, construction drain, surface water sampling and leak detection system (LDS) monitoring for the Allen Steam Station South Starter Landfill (SSLF) (Permit No.: 3620-INDUS-2022), located near Belmont, in Gaston County, North Carolina. On March 10, 2026, samples were collected from the SSLF leachate collection system (LCS) and construction drain. No sample was able to be collected from the surface water location since it was dry. The samples were collected by Duke Energy personnel and analyzed by the Duke Energy Analytical Laboratory. A summary of monitoring results can be found in the attached ECMR. The parameters tested are not bound by state groundwater or surface water standards. All laboratory analytical and field results are provided in the appendices of the Report. Allen Steam Station's SSLF is sampled semi-annually, typically during the months of March and September. The next landfill sampling event is scheduled for September 2026 with documentation to follow. If you need additional information regarding this submittal do not hesitate to email or call me at Courtney.Murphy@duke-energy.com or (704) 382-7171. Respectfully, dwh1w1fl" Courtney W. Murphy, P.G. Environmental Services www.duke-energy.com Page 1 of 2 Attachments: Environmental Controls Monitoring Semiannual Report — September 2025 through March 2026 (SynTerra, June 30, 2026) cc (via e-mail): Jordan Russ, NCDEQ Elizabeth Werner, NCDEQ Sherri Stanley, NCDEQ Ben Dawkins, Duke Energy Sheila Westcott, Duke Energy Kenneth McKinney, Duke Energy Charlie Smith, Duke Energy Tyler Hardin, Duke Energy Kim Witt, Duke Energy www.duke-energy.com Page 2 of 2 NC DEQ Division of Waste Management Environmental Monitoring Solid Waste Section Reporting Form Note: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Instructions: Prepare one form for each individually monitored unit. List complete permit IDs lie, 0101-MSWLF-1972, 0101-CDLF-1962, etc) Type or print legibly. Groundwater: Attach a notification table with values that attain or exceed NC 2L groundwater standards and/or other applicable groundwater protection standards. Surface Water: Attach a notification table with values that attain or exceed NC 2B surface water standards. Landfill Gas: Attach a notification table of any methane gas values that attain or exceed explosive gas levels. Notification tables must include a preliminary analysis of the cause and significance of each value, as known or suspected. Submit electronic or hardcopy signed and sealed form, tables, and Electronic Data Deliverables to the Section Hydrogeologist assigned to the facility. Hard copies can be mailed to: Environmental Compliance Branch, NCDEQ-DWM, Solid Waste Section, 1646 Mail Service Center, Raleigh, NC 27699-1646 Solid Waste Monitoring Data Submittal Information NAME of ENTITY submitting data (ie, laboratory, consultant, facility owner): Duke Energy (owner) CONTACT: Courtney Murphy 704-382-7171 courtne mur h duke-ener com Name: y p y Phone: E-mail: y P y@ gy Permit ID (i.e., 101 0-MSWLF-1 980) NC Landfill Rule: Facility Name: * List all that apply * County (.0500 or .1600) Sample Collection Date(s) Duke Allen 3620-INDUS .0500 March 10, 2026 South Starter Landfill Gaston Environmental Status: (Check all that apply) ❑ Initial/Baseline Monitoring W1 Detection Monitoring ❑ Assessment Monitoring ❑ Corrective Action Type of Data submitted: (Check all that apply) Groundwater monitoring data from monitoring wells ❑ Methane gas monitoring data Groundwater monitoring data from private water supply wells F7 Corrective action data (specify) ✓ Leachate monitoring data Surface water monitoring data 9✓ Other (specify) Construction Drain Discharge Notification Attached? MNO. No groundwater, surface water, or landfill gas standards were exceeded. YES - a notification of values exceeding a groundwater or surface water standard is attached. It includes a list of groundwater and surface water monitoring points, dates, analytical values, NC 2L groundwater standard, NC 2B surface water standard or NC Solid Waste GWPS; and a preliminary analysis of the cause and significance of any exceedance. ❑ YES - a notification of values exceeding an explosive methane gas limit is attached. It includes the methane monitoring points, dates, sample values and explosive methane gas limits. CERTIFICATION To the best of my knowledge, the information reported, and statements made on this data submittal and attachments are true and correct. Furthermore, I have attached complete notification of any sampling values meeting or exceeding groundwater or surface water standards or explosive gas levels, and a preliminary analysis of the cause and significance of concentrations exceeding standards. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. Courtney W. Murphy, P.G. Lead Environmental Specialist Facility Representative Name (Print) Title 6/30/2026 Affix NC Licensed/ Professional Geologist or PE Seal Signature Date N ``,`CrAR .•• O 525 S. Tryon St, Charlotte, NC 28202 oQ-.�,�G�NS Facility Representative Address Z = f+ :y #F-0566 203 NC Geological Corporation Number or NC PE Firm License Number Gj•:' ,> O FOL OG ••• Q (if applicable effective May 1, 2009) '. �/ Q- Revised EY"M����`�' 10101/2025 Environmental Controls Monitoring Semiannual Report September 2025 through March 2026 Allen Steam Station South Starter Landfill (Permit No. 3620-INDUS) Gaston County, North Carolina DUKE ENERGY CAROLINAS PREPARED FOR: Duke Energy Carolinas, LLC June 30, 2026 Christopher Suttell Project Manager, NC L.G. 2426 Hanna Cunningham Staff Scientist Scott Spinner Senior Peer Reviewer Environmental Controls Monitoring Semiannual Report September 2025 through March 2026 South Starter Landfill (Permit No. 3620-INDUS) Table of Contents 1.0 Background...................................................................................................................................1 1JSite Description................................................................................................................................... 1 1.1.1 South Starter Landfill.................................................................................................................... 1 1.1.2 Leachate Basin............................................................................................................................. 2 1.1.3 Construction Drain....................................................................................................................... 2 1.1.4 Surface Water Management.........................................................................................................2 1.2 Summary of Site Geology and Hydrology............................................................................................... 3 2.0 Monitoring, Sampling, and Analysis Locations and Methods............................................................... 4 2.1 Leak Detection System Monitoring....................................................................................................... 4 22 Leachate Sampling and Analysis............................................................................................................ 4 23 Construction Drain Outlet Sampling and Analysis................................................................................... 4 2.4 Surface Water Sampling and Analysis.................................................................................................... 5 3.0 Monitoring, Sampling, and Analysis Results...................................................................................... 6 3.1 Leak Detection System Monitoring Results............................................................................................6 3.2 Leachate and Analytical Results............................................................................................................ 6 3.3 Construction Drain Outlet Analytical Results.......................................................................................... 6 3.4 Surface Water Analytical Results........................................................................................................... 7 4.0 References....................................................................................................................................8 Page i Environmental Controls Monitoring Semiannual Report South Starter Landfill (Permit No. 3620-INDUS) September 2025 through March 2026 List of Drawings Drawing 1 Site Location Map Drawing 2 Monitoring Locations List of Tables Table 1 Leak Detection System Monitoring Results —South Starter Landfill Table 2 Leachate Analytical Results — March 10, 2026 Table 3 Construction Drain Outlet Analytical Results — March 10, 2026 List of Appendices Appendix A Field Sampling Forms Appendix B Laboratory Reports, Data Validation Checklists, and Chain -of -Custody Forms Page ii Environmental Controls Monitoring Semiannual Report September 2025 through March 2026 South Starter Landfill (Permit No. 3620-INDUS) 1.0 Background This Environmental Controls Monitoring Semiannual Report documents monitoring results pertaining to the South Starter Landfill (SSLF or landfill; Permit No. 3620-INDUS) located at the Duke Energy Carolinas, LLC (Duke Energy) Allen Steam Station (Allen, Station, or Site). The monitoring results in this report are for the period of September 2025 through March 2026. The Environmental Controls Monitoring Plan (ECMP) establishes locations and procedures for monitoring the early detection of solid waste or leachate potentially released to the environment from the SSLF. The Environmental Control Monitoring Plan, Revision 2 (ECMP, Revision 2; SynTerra, 2025) was submitted to the North Carolina Department of Environmental Quality (NCDEQ) Division of Waste Management (DWM) on May 23, 2025, and approved by the NCDEQ DWM on June 16, 2025. The March 2026 monitoring event and this report comply with the ECMP, Revision 2 (SynTerra, 2025). The landfill is designed and constructed in accordance with North Carolina General Statute (G.S.) 130A-295.4 for Combustion Products Landfills as discussed in the ECMP, Revision 2 (SynTerra, 2025). The procedures established in the ECMP, Revision 2 and the associated monitoring documented in this report are intended to satisfy the water quality monitoring plan required by North Carolina Administrative Code (NCAC), Title 15A, Subchapter 13B .0504(c)(8)(D) in accordance with G.S. 130A-295.4(c). 1.1 Site Description A summarized description of the SSLF is provided below. A more detailed description of the SSLF and the Site is presented in the ECMP, Revision 2 (SynTerra, 2025). The Station is no longer used for power generation and is now in the process of being decommissioned. The SSLF [in accordance with G.S. 130A-295.4(b)] is constructed with a base liner system that includes a primary and secondary geomembrane liner. The primary and secondary liners are separated by a geocomposite drainage layer to create a leak detection layer. The geocomposite provides enough capacity to convey liquid that enters the leak detection layer to a sump area (lowest elevation in an area of the liner system), where it is collected for removal by mechanical pumping. Removal of liquid from the leak detection layer, in addition to the combination of a geosynthetic clay liner (GCL) and compacted soil liner beneath the secondary liner, reduces the potential for liquid to enter the environment. The quantity of liquid removed from the leak detection layer is measured and recorded. 1.1.1 South Starter Landfill The approximately 22-acre SSLF is located primarily south of the Active Ash Basin (AAB) but partially overlaps the southeast portion of the AAB (Drawing 1). The SSLF is bound by the AAB to the north, upland areas to the south and west, and lowland areas and the Catawba River (Lake Wylie) to the east (Drawing 2). Most of the waste intended for placement throughout the life of the landfill consists of coal combustion residuals (CCR), predominantly fly ash and bottom ash. The approved waste streams are provided in the Operations Plan — Revision 1, Allen Steam Station South Starter Landfill Permit No. 3620-INDUS) (Operations Plan; AECOM, 2025). Leachate from the SSLF is primarily conveyed via force main to the on -Site wastewater treatment system (WWTS); however, a secondary conveyance to the Leachate Basin via force main is available for temporary storage when the WWTS is off line. Leachate conveyance from the Leachate Basin is described in Section 1.1.2. Page 1 Environmental Controls Monitoring Semiannual Report September 2025 through March 2026 South Starter Landfill (Permit No. 3620-INDUS) The SSLF received a Permit to Operate on July 22, 2025, and began receiving CCR on July 30, 2025. 1.1.2 Leachate Basin The approximately 3-acre Leachate Basin is located within the northwestern portion of the AAB and is bounded by the Retired Ash Basin (RAB) to the north, AAB to the east and south, and upland areas to the west (Drawing 1 and Drawing 2). Leachate Basin monitoring results are included in a separate environmental controls monitoring report. Leachate from the Leachate Basin is pumped via force main to the on -Site WWTS, where it is comingled with other wastewater for treatment. Flows from the on -Site WWTS are discharged to the Catawba River (Lake Wylie) through Outfall 002 in accordance with National Pollutant Discharge Elimination System (NPDES) Permit NC0004979 (Drawing 2). In a letter dated October 2, 2024, the NCDEQ granted interim approval for operation of a temporary pumping system and to place CCR as interim cover in the Leachate Basin. Final approval of Leachate Basin operation was granted on November 14, 2023, after the permanent pumping system was in place and upon receipt of the NCDEQ's approval of the Leachate Basin Construction Certification Report, Volumes 1 through 3 (FID 1776828, FID 1818490, and FID 1820954), which contained construction quality assurance information. The Leachate Basin began operating on November 14, 2023, receiving leachate from the North Starter Landfill (NSLF). The Leachate Basin began to receive leachate from the SSLF upon approval of the Permit to Operate received July 22, 2025; however, leachate from the SSLF is primarily routed directly to the on -Site WWTS. 1.13 Construction Drain A gravity flow construction drain was installed beneath the SSLF for the purpose of maintaining groundwater elevations in the area at levels at least 4 feet below the composite liner system. The SSLF construction drain is composed of a 6-inch high -density polyethylene (HDPE) DR-11 perforated piping network placed beneath the composite liner system of the SSLF (Drawing 2). The pipes are surrounded by 6 inches of stone with a geotextile wrap and convey collected groundwater for discharge via 6-inch solid HDPE DR-11 piping. The construction drain was completed in May 2024 and has been operational since that time. The construction drain outlet sample location, ALN-SSLF-CD1B, is at the terminus of discharge pipes within a wet well structure adjacent to the northeastern corner of the SSLF (Drawing 2). Construction drain discharge from the wet well is pumped to either the AAB Polishing Pond or a lined equalization basin within the AAB temporarily before being collected and managed through the on -Site WWTS and discharged to the Catawba River (Lake Wylie) through Outfall 002 (Drawing 2) in accordance with NPDES Permit NC0004979. 1.1.4 Surface Water Management The SSLF was designed to provide separation of contact water from non -contact stormwater. Contact stormwater is managed as leachate. Non -contact stormwater runoff from the landfill is conveyed to the perimeter channel network via a series of tack -on berms, benches, and down chutes. Page 2 Environmental Controls Monitoring Semiannual Report September 2025 through March 2026 South Starter Landfill (Permit No. 3620-INDUS) No surface water streams are upgradient of the SSLF. An intermittent stream originates immediately downgradient of the SSLF disposal area. When flow is sufficient, surface water is sampled at one location (ALN-SSLF-SW1) within the intermittent stream down and side -gradient of the SSLF (Drawing 2). 1,2 Summary of Site Geology and Hydrology The groundwater system at Allen is consistent with the regolith-fractured rock system and is characterized as an unconfined, interconnected aquifer system indicative of the Piedmont physiographic province in which the Site is contained. The groundwater system at the Site is divided into the following three flow layers to distinguish the interconnected groundwater system: the shallow flow zone, the deep flow zone (transition zone), and the bedrock flow zone. The AAB, RAB, Distribution of Residual Solids (DORS) Fills (which includes two ash storage areas and two structural fills), RAB Ash Landfill, NSLF, and SSLF are contained within former perennial stream valleys (the flow compartment) (Drawing 1). Groundwater within the flow compartment is a flow - through system. In the vicinity of the SSLF, groundwater enters the system from the upgradient end in the western portion of Duke Energy property boundary and flows laterally beneath the central portions of the AAB and SSLF and downward near the AAB dam. Beyond the dam, groundwater flows toward and discharges to the Catawba River (Lake Wylie). A groundwater divide is present in the vicinity of the SSLF to the west and south of the SSLF . The groundwater divide is upgradient of the SSLF and roughly follows topography along South Point Road (to the west) and Reese Wilson Road (to the south) (Drawing 1). The topographically controlled flow direction provides natural hydraulic control of groundwater in the vicinity of the SSLF, ash basins, and adjacent sources within the flow compartment. Page 3 Environmental Controls Monitoring Semiannual Report September 2025 through March 2026 South Starter Landfill (Permit No. 3620-INDUS) 2.0 Monitoring, Sampling, and Analysis Locations and Methods 2.1 Leak Detection System Monitoring Leak detection monitoring occurs in the vicinity of the landfill sump at ALN-SSLF-LDS1 (Drawing 2). Performance of the leak detection system (LDS) is determined by the average monthly quantity of liquid removed from the leak detection layer. Each leak detection discharge pump is equipped with a pump totalizer (flow meter). The flow meter rates were monitored and recorded as defined in the Operations Plan (AECOM, 2025). Leak detection monitoring results are summarized in Section 3.1. 2.2 Leachate Sampling and Analysis A discrete leachate sample was collected from the leachate collection discharge in the vicinity of the landfill sump at ALN-SSLF-LCS1 on March 10, 2026. The leachate sample location is shown on Drawing 2. Duke Energy personnel collected samples and documented the sampling in accordance with procedures provided in Duke Energy's Landfill Sample Collection Guideline (SynTerra, 2023, Appendix 1). Copies of the field sampling forms are included in Appendix A. The parameters and constituents reported were sampled in accordance with Table 1 of the approved ECMP, Revision 2 (SynTerra, 2025). The Duke Energy Analytical Laboratory (North Carolina Laboratory Certification No. 248) performed sample analysis for the constituents listed in the ECMP, Revision 2 (SynTerra, 2023. The laboratory report and chain -of -custody (COC) forms are included in Appendix B. The leachate samples were measured for the following parameters in the field: • pH, specific conductivity, temperature, dissolved oxygen, and oxidation-reduction potential using a water quality meter • Turbidity using a turbidity meter The leachate samples were analyzed in the laboratory for the following constituents: • Barium, boron, calcium, iron, lithium, magnesium, manganese, and zinc using U.S. Environmental Protection Agency (USEPA) Method 6010D • Antimony, arsenic, beryllium, cadmium, chromium, cobalt, copper, lead, molybdenum, nickel, selenium, silver, thallium, and vanadium using USEPA Method 6020B • Chloride, fluoride, nitrate (as nitrogen), and sulfate using USEPA Method 9056A • Mercury using USEPA Method 7470A • Total dissolved solids using Standard Method (SM) 2540C Leachate field parameters and analytical results are summarized in Section 3.2. 2.3 Construction Drain Outlet Sampling and Analysis A construction drain outlet sample was collected from ALN-SSLF-CD1B on March 10, 2026 (Drawing 2). Page 4 Environmental Controls Monitoring Semiannual Report September 2025 through March 2026 South Starter Landfill (Permit No. 3620-INDUS) Copies of the field calibration and sampling forms are included in Appendix A. The parameters and constituents reported were sampled in accordance with Table 1 of the approved ECMP, Revision 2 (SynTerra, 2025). The Duke Energy Analytical Laboratory performed sample analysis for the constituents listed in the ECMP, Revision 2 (SynTerra, 2023). The laboratory report and COC forms are included in Appendix B. The construction drain outlet sample was measured for the same set of parameters and constituents as the leachate samples (Section 2.2) and the following additional parameters and constituents: • Beryllium (dissolved), cadmium (dissolved), chromium (dissolved), copper (dissolved), lead (dissolved), nickel (dissolved), and silver (dissolved) using USEPA Method 6020B • Total hardness and zinc (dissolved) using USEPA Method 6010D Construction drain outlet field parameters and analytical results are summarized in Section 3.3. 2.4 Surface Water Sampling and Analysis Surface water is sampled from an intermittent stream that flows downgradient and side -gradient of the SSLF to the south from sample location ALN-SSLF-SW1 (Drawing 2). However, a surface water sample was not collected during the March 2026 sampling event because of insufficient flow within the stream channel. Page 5 Environmental Controls Monitoring Semiannual Report September 2025 through March 2026 South Starter Landfill (Permit No. 3620-INDUS) 3.0 Monitoring, Sampling, and Analysis Results 3.1 Leak Detection System Monitoring Results Leakage rates were less than the initial response leakage rate (IRLR) and action leakage rate (ALR) during the reporting period. An average daily leakage rate is calculated for the operational SSLF each month and compared to the IRLR and ALR for the landfill LDS as defined in the Operations Plan (AECOM, 2025). Average daily leakage rates for the SSLF were calculated as follows: 1. Calculate the monthly total volume pumped (gallons): monthly volume pumped (gallons) = current month total flow meter reading — preceding month total flow meter reading 2. Calculate the average daily leakage rate [gallons per acre per day (gpad)]: average daily leakage rate (gpad) = monthly volume pumped (gallons) - landfill cell area (acres) monitoring duration (days) The LDS monitoring results for location ALN-SSLF-LDS1 are included in Table 1. The LDS leakage rate data collection details are kept with on -Site records. No leakage rates or notable variances in the data outside of the normal operating range for the landfill were observed during the monitoring period. 3.2 Leachate and Analytical Results Leachate analytical results are not compared to surface water or groundwater quality standards. The leachate analytical results for ALN-SSLF-LCS1 are included in Table 2. As normal laboratory practice, select samples were diluted to within the calibrated range of analysis. Specific information regarding the diluted samples, including the dilution factor, is reported in the electronic data deliverable and the laboratory analytical report. The laboratory analytical report, data validation checklist, and COC form associated with data collected as part of this semiannual monitoring period are included in Appendix B. 3.3 Construction Drain Outlet Analytical Results Construction drain outlet analytical results are not compared to surface water or groundwater quality standards. The construction drain outlet analytical results for ALN-SSLF-CD1B are included in Table 3. The construction drain outlet sample is included in the same laboratory analytical report, data validation checklist, and COC form as the leachate data collected as part of this semiannual monitoring period (Appendix B). Page 6 Environmental Controls Monitoring Semiannual Report September 2025 through March 2026 South Starter Landfill (Permit No. 3620-INDUS) 3.4 Surface Water Analytical Results During the March 2026 sampling event, a surface water sample was not collected because of insufficient flow within the intermittent stream channel at designated sample location ALN-SSLF-SW1; therefore, there are no surface water analytical results to report. Page 7 Environmental Controls Monitoring Semiannual Report September 2025 through March 2026 South Starter Landfill (Permit No. 3620-INDUS) 4.0 References AECOM. (2021). Engineering and Facility Plan, Revision 1 — Duke Energy Carolinas, LLC., Allen Steam Station —South Starter Landfill, Permit No. 3620-INDUS. March 26, 2021. AECOM. (2025). Operations Plan, Revision 1 — Duke Energy Carolinas, LLC., Allen Steam Station —South Starter Landfill, Permit No. 3620-INDUS. May 16, 2025. SynTerra. (2023). Environmental Control Monitoring Plan, Revision 2 — Duke Energy Carolinas, LLC., Allen Steam Station —South Starter Landfill, Permit No. 3620-INDUS. May 2025. Page 8 Environmental Controls Monitoring Semiannual Report September 2025 through March 2026 South Starter Landfill (Permit No. 3620-INDUS) Drawings r)B r v --3 .. I r:'.r a. - — FORMER LINED 1 sa`.I:a•',4;: RETENTION BASIN ` ! dhc WijH, CANAL ROAD:! r LANDFILL = DUKE ENERGY I PROPERTY BOUNDARY I FORMER GYPSUM PAD r/ J FALLEN STEAM STATION DISCHARGE �� FORMER COAL CANAL PILE AREA r" r� = J ,NORTHSTARTER RETIRED ASH BASIN I LANDFILL 3619-INDUS RETIRED ASH BASIN AfyfN?r;•" !JokS' I ASH LANDFILL ti7a +`♦ ` 1_ _ ^ _ 3612-INDUS f LEACHATE 111 BASIN 1 ' 1 ASH BASIN ~ ACTIVE LANDFILL ASH BASIN 3621-INDUS , J t (00- AN x f` SOUTH STARTER LANDFILL----- nk 3620-INDUS LAO N 6--1:Gid.3MI NOTES: 1. BOUNDARIES PROVIDED BY DUKE ENERGY AND ARE APPROXIMATE. 2. WATER FEATURES DEPICTED WITHIN WASTE BOUNDARIES OF THE ASH BASINS ON THE USGS TOPOGRAPHIC MAP DO NOT REPRESENT CURRENT CONDITIONS. 3. UNITED STATES GEOLOGICAL SURVEY TOPOGRAPHIC MAP OBTAINED FROM ESRI. LAST UPDATED OCTOBER 2025. DUKE ENERGY CAROLINAS k' Terra l rr. DRAWING 1 SITE LOCATION MAP ENVIRONMENTAL CONTROLS MONITORING SEMIANNUAL REPORT SOUTH STARTER LANDFILL (PERMIT NO. 3620-INDUS) SEPTEMBER 2025 THROUGH MARCH 2O26 ALLEN STEAM STATION GASTON COUNTY, NORTH CAROLINA �I GASTON ' DRAWN BY: C. NORRIS DATE: 12/31/2025 GRAPHIC SCALE COUNTY REVCHECKEE DBY: HC CUNNINGH AM : 0PPROV6/30/2026 1000 0 (IN FEET) s000 2000 'IYPYYBCOYD.com PROJECT MANAGER: C. SUTTELL LAYOUT NAME: DRAW1_ALLEN USGS LOCATIONjNAP_SSLF r— I� Ar .. A LEGEND / 4 O CONSTRUCTION DRAIN OUTLET SAMPLING LOCATION O LEACHATE SAMPLING LOCATION 0 • LEACHATE DETECTION SYSTEM MONITORING • SURFACE WATER SAMPLING LOCATION NPDES OUTFACE j I i ❑ CONSTRUCTION DRAIN WET WELL i /' •' I,' �,_ _ CONSTRUCTION DRAIN of ALN—SSLF—LDS1 ALN—SSLF—CD1A —.. .6 A�' LEACHATE FORCE MAIN �. ft . , — — — CURRENT TEMPORARY LEACHATE FORCE MAIN - . � � — — —LEACHATE BASIN 4 _ — — —ASH BASIN LANDFILL BOUNDARY R r NORTH STARTER LANDFILL BOUNDARY ALN—SSLF—LCS1 1 L — — — SOUTH STARTER LANDFILL BOUNDARY CANAL ROAD LANDFILL BOUNDARY O SITE FEATURES ALN—SSLF—CD1 B — — — L — _ _ e - ' .ACTIVE ASH BASIN WASTE BOUNDARY I i L RETIRED ASH BASIN WASTE BOUNDARY y _ - L RETIRED ASH BASIN ASH LANDFILL WASTE BOUNDARY DORS FILLS BOUNDARIES DUKE ENERGY PROPERTY BOUNDARY SURFACSTREAMEAMATER FLOW EC NRTR ODIRECTION --- c ) I ` ' WETLAND (AMEC NRTR 2015) / I_ NOTES: ALN—SSLF—SW11. THE WATERS OF THE US HAVE NOT BEEN APPROVED BY THE US ARMY CORPS OF ENGINEERS AT THE TIME OF THE MAP CREATION. THIS MAP IS A PRELIMINARY I JURISDICTIONAL DETERMINATION ONLY. THE WETLANDS AND STREAMS BOUNDARIES WERE INSET SCALE: 1" = 400' \I OBTAINED FROM AMEC FOSTER WHEELER ENVIRONMENTAL & INFRASTRUCTURE, INC. NATURAL RESOURCE TECHNICAL REPORT FOR ALLEN STEAM STATION DATED MAY 29, 2015. A. -NPDES 2. BOUNDARIES PROVIDED BY DUKE ENERGY AND ARE APPROXIMATE. 3. AERIAL IMAGERY IS A COMBINATION OF DUKE ENERGY PROPELLER AERIAL PHOTOGRAPHY 'ALN-SSLF-Lost ALNSSLF-CD1A CAPTURED ON MARCH 23, 2026 AND MAXAR IMAGERY FROM ESRI CAPTURED ON MAY 28, 2024. F �- Aw-ssLFcole 4. DRAWING HAS BEEN SET WITH A PROJECTION OF NORTH CAROLINA STATE PLANE ALN-SSLF-LCS1 COORDINATE SYSTEM FIPS 3200 (NAD 83). 5. FOR CONSTRUCTION DRAIN DETAILS, SEE RESPECTIVE LANDFILL CONSTRUCTION QUALITY ASSURANCE REPORTS BY WSP USA, INC. 6. DORS -DISTRIBUTION OF RESIDUAL SOLIDS ALNSSLF-SW1 7. NPDES - NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM 8. LEACHATE FORCE MAIN ALIGNMENT PROVIDED BY AECOM ON JANUARY 7, 2026. GRAPH IC SCALE (' DUKE 500 0 500 1,000 DRAWING 2 ENERGY MONITORING LOCATIONS CAROLINA UN FEET) ENVIRONMENTAL CONTROLS MONITORING SEMIANNUAL REPORT DRAWN BY:C. NORRIS DATE: 12/31/2025 SOUTH STARTER LANDFILL(PERMIT NO. 3620-INDUS) REVISEDBY:C.NORRIS DATE:06/30/2026 SEPTEMBER 2025 THROUGH MARCH 2O26 CHECKED BY: H. CUNNINGHAM DATE:06/30/2026 ALLEN STEAM STATION APPROVED BY:C. SUTTELL DATE:06/30/2026 PROJECT MANAGER: C. SUTTELL GASTON COUNTY, NORTH CAROLINA PATH: G:\OARCGIS PRO PROJECTS\DUKE_ENERGY\ALLEN\2026\ENVIRONMENTALCONTROLSMONITORINGRPT\ECMR_2026.APRX LAYOUT NAME: DRAW2 ALLEN MONITORING LOCATIONS SSLF Environmental Controls Monitoring Semiannual Report September 2025 through March 2026 South Starter Landfill (Permit No. 3620-INDUS) Tables TABLE 1 LEAK DETECTION SYSTEM MONITORING RESULTS - SOUTH STARTER LANDFILL ENVIRONMENTAL CONTROLS MONITORING SEMIANNUAL REPORT SOUTH STARTER LANDFILL (PERMIT NO. 3620-INDUS) SEPTEMBER 2025 THROUGH MARCH 2O26 ALLEN STEAM STATION DUKE ENERGY CAROLINAS, LLC, GASTON COUNTY, NORTH CAROLINA ALN-SSLF-LSD1 MONTHLY MONTHLY TOTAL AVERAGE AVERAGE DAILY AVERAGE DAILY MONITORING MONITORING DURATION VOLUME VOLUME SSLF DAILY LEAKAGE RATE LEAKAGE RATE PERIOD (DAYS) TOTAL RAINFALL PUMPED PUMPED AREA LEAKAGE EXCEEDS IRLR: EXCEEDS ALR: COMMENTSt (GALLONS)' (GALLONS)' (ACRES)2 RATE 316 GPAD 421 GPAD (INCHES)' (GPAD) (YES/NO) (YES/NO) LDS PUMP TOTALIZER September 2025 30 2.38 727 9,725 22 4.33 NO NO LDS pump level was triggered October 2025 31 2.62 1 9,726 0.00 NO NO -- November 2025 30 0.54 4 9,730 0.01 NO NO -- December 2025 31 1.82 753 10,483 0.97 NO NO LDS pump level was triggered January 2026 31 1 10 10,493 0.01 NO NO -- February 2026 20 0 10 10,503 0.02 NO NO March 2026 31 1 17 10,520 0.02 NO NO Prepared by: HCC Checked by: TAW Notes: ' Data and comments provided by Duke Energy Carolinas, LLC. 2 As presented in the Engineering and Facility Plan, Revision 1, Allen Steam Station, South Starter Landfill, Prepared by AECOM Technical Services of North Carolina, Inc., Dated: March 26, 2021. -- no comments made ALR- The Action Leakage Rate is 421 GPAD, as presented in the Engineering and Facility Plan - Revision 1 (AECOM, 2021). GPAD - gallons per acre per day IRLR- The Initial Response Leakage Rate is 316 GPAD, as presented in the Engineering and Facility Plan - Revision 1 (AECOM, 2021). LDS - Leak Detection System SSLF - South Starter Landfill TABLE 2 LEACHATE ANALYTICAL RESULTS - MARCH 10, 2026 ENVIRONMENTAL CONTROLS MONITORING SEMIANNUAL REPORT SEPTEMBER 2025 THROUGH MARCH 2O26 SOUTH STARTER LANDFILL (PERMIT NO. 3620-INDUS) ALLEN STEAM STATION DUKE ENERGY CAROLINAS, LLC, GASTON COUNTY, NORTH CAROLINA Constituent ALN SSLF-LCS1 Field Parameters pH (S.U.) 6.9 Temperature (Deg C) 22 Specific Conductance (µmhos/cm) 1,121 Dissolved Oxygen (mg/L) 3.6 Oxidation -Reduction Potential (mV) 281 Turbidity (NTUs) NM Laboratory Analyses Antimony 0.961 J Arsenic 3.16 Barium 108 Beryllium < 2 Boron 1,710 Cadmium 0.108 J Calcium (mg/L) 287 Chloride (mg/L) 16 Chromium 1.351 Cobalt 0.977 J Copper 8.09 Fluoride (mg/L) 0.081 Iron 1,160 Lead 1.11 J Lithium 16 BJ Magnesium (mg/L) 42.5 Manganese 240 Mercury 0.01 J Molybdenum 219 Nickel 4.07 Nitrate (as nitrogen) (mg-N/L) 0.27 Selenium 736 Silver < 2 Sulfate (mg/L) 680 Total Dissolved Solids (TDS) (mg/L) 1,330 Thallium 0.222 J Vanadium 10.2 Zinc 71 Prepared by: HCC Checked by: TAW Notes: Analytical data presented in this table reflect the Duke Energy Biological Analytical Data Storage System (BASS) as of April 21, 2026. Analytical results presented in micrograms per liter (µg/L) unless otherwise noted. <- Concentration not detected at or above the adjusted reporting limit. B- Target analyte was detected in Method/Prep Blank(s) at a concentration greater than Y2 the reporting limit but less than the reporting limit. Analyte concentration in sample is valid and may be used for compliance purposes. J - Value is estimated. The result is below the reporting limit or potentially biased based on data validation. NM - not measured S.U. - standard units Deg C - degrees Celsius µmhos/cm - micromhos per centimeter mg/L- milligrams per liter mV - millivolts NTUs - nephelometric turbidity units mg-N/L - milligrams nitrogen per liter µg/L - micrograms per liter TABLE 3 CONSTRUCTION DRAIN OUTLET ANALYTICAL RESULTS - MARCH 10, 2026 ENVIRONMENTAL CONTROLS MONITORING SEMIANNUAL REPORT SOUTH STARTER LANDFILL (PERMIT NO. 3620-INDUS) SEPTEMBER 2025 THROUGH MARCH 2O26 ALLEN STEAM STATION DUKE ENERGY CAROLINAS, LLC, GASTON COUNTY, NORTH CAROLINA Constituent ALN-SSLF-CD1B Field Parameters pH (S.U.) 5.9 Temperature (Deg C) 21 Specific Conductance (µmhos/cm) 213 Dissolved Oxygen (mg/L) 5.11 Oxidation -Reduction Potential (mV) 289 Turbidity (NTUs) 1.0 Laboratory Analyses Antimony < 1 Arsenic < 1 Barium 232 Beryllium < 1 Beryllium (dissolved) < 1 Boron 370 Cadmium 0.053 J Cadmium (dissolved) 0.062 J Calcium (mg/L) 25.3 Chloride (mg/L) 63 Chromium 3.3 Chromium (dissolved) 3.13 Cobalt 1.4 Copper 0.924 J Copper (dissolved) 1.91 Fluoride (mg/L) < 0.1 Iron 15 Lead < 1 Lead (dissolved) < 1 Lithium 9 BJ Magnesium (mg/L) 7.98 Manganese 111 Mercury 0.05 J Molybdenum < 1 Nickel 1.75 Nickel (dissolved) 1.78 Nitrate (as nitrogen) (mg-N/L) 0.12 Selenium 0.737 J Silver < 1 Silver (dissolved) < 1 Page 1 of 2 TABLE 3 CONSTRUCTION DRAIN OUTLET ANALYTICAL RESULTS - MARCH 10, 2026 ENVIRONMENTAL CONTROLS MONITORING SEMIANNUAL REPORT SOUTH STARTER LANDFILL (PERMIT NO. 3620-INDUS) SEPTEMBER 2025 THROUGH MARCH 2O26 ALLEN STEAM STATION DUKE ENERGY CAROLINAS, LLC, GASTON COUNTY, NORTH CAROLINA Constituent ALN-SSLF-CD1B Laboratory Analyses (Continued) Sulfate (mg/L) 22 Total Dissolved Solids (TDS) (mg/L) 233 Total Hardness 96 Thallium 0.047 J Vanadium 0.668 J Zinc 6 J Zinc (dissolved) 6 J Prepared by: HCC Checked by: TAW Notes: Analytical data presented in this table reflect the Duke Energy Biological Analytical Data Storage System (BASS) as of April 21, 2026. Analytical results presented in micrograms per liter (µg/L) unless otherwise noted. <- Concentration not detected at or above the adjusted reporting limit. B- Target analyte was detected in Method/Prep Blank(s) at a concentration greater than % the reporting limit but less than the reporting limit. Analyte concentration in sample is valid and may be used for compliance purposes. J - Value is estimated. The result is below the reporting limit or potentially biased based on data validation. S.U. - standard units Deg C - degrees Celsius µmhos/cm - micromhos per centimeter mg/L - milligrams per liter mV - millivolts NTUs - nephelometric turbidity units mg-N/L - milligrams nitrogen per liter µg/L - micrograms per liter Page 2 of 2 Environmental Controls Monitoring Semiannual Report September 2025 through March 2026 South Starter Landfill (Permit No. 3620-INDUS) Appendix A Field Calibration and Sampling Forms ,Ifa6, DUKE Z"FNERGY Duke Energy Groundwater Sampling Field Data Form Well ID: ALN_SSLF-CD1B Date:10 Mar 2026 nny, Air Tump:72 deg F Site ID ALN Purge Method / Pump Intake Depth Equipment Purge / --- --- Reference Elevation --- --- Project Name LF Purge Equipment Peristaltic pump Initial Depth to Water 0 ft Appearance Clear, None Total Volume Purged 21 g Total Well Depth* --- --- Pump Condition --- Volume of Water in Well --- 9 Well Diameter / Well Screen Interval* 2 in / --- - --- --- Sampler Name: CJZ Date and Time: 3/10/2026 10:10 Sample ID(s): ALN_SSLF-CD1B_20260310-1010_LF Purging Comments: Sampling Comments: 2026003774 QAQC Sample(s): --- Time DTW Flow Rate (ml/min) Purge Volume (g) Temperature (C) pH (SU) Specific Conductivity (US/cm) Dissolved Oxygen (mg/1) ORP (mV) Turbidity (NTU) 3/10/26 10:07 AM --- 250 0 21 5.94 213 5.11 289 1 * = measured from ground surface ,Ifa6, DUKE Z"FNERGY Duke Energy Groundwater Sampling Field Data Form Well ID: ALN_SSLF-LCS1 Date:10 Mar 2026 nny, Air Tump:72 deg F Site ID ALN Purge Method / Pump Intake Depth Equipment Purge / --- --- Reference Elevation --- --- Project Name LF Purge Equipment Grab Sample Initial Depth to Water 0 ft Appearance Clear, None Total Volume Purged --- g Total Well Depth* --- --- Pump Condition --- Volume of Water in Well --- Well Diameter / Well Screen Interval* Sampler Name: CJZ Date and Time: 3/10/2026 10:20 Sample ID(s): ALN_SSLF-LCS1_20260310-1020_LF Purging Comments: Sampling Comments: 2026003776 QAQC Sample(s): --- Time DTW Flow Rate (ml/min) Purge Volume (g) Temperature (C) pH (SU) Specific Conductivity (US/cm) Dissolved Oxygen (mg/1) ORP (mV) Turbidity 3/10/26 10:18 AM --- 500 0 22 6.85 1121 3.56 281 --- * = measured from ground surface ,Ifa6, DUKE Z"FNERGY Duke Energy Groundwater Sampling Field Data Form Well ID: ALN_SSLF-SW1 Date:10 Mar 2026 nny, Air Tump:72 deg F Site ID ALN Purge Method / Pump Intake Depth --- / --- --- Reference Elevation --- --- Project Name LF--- Purge Equipment Initial Depth to Water --- --- Appearance --- Total Volume Purged --- --- Total Well Depth* --- --- Pump Condition --- Volume of Water in Well --- --- Well Diameter / Well Screen Interval* 2 in / --- - --- --- Sampler Name: CJZ Date and Time: --- Sample ID(s): Well Dry Purging Comments: Sampling Comments: QAQC Sample(s): --- Time DTW Flow Rate Purge Volume Temperature pH Specific Conductivity Dissolved Oxygen ORP Turbidity 3/10/26 10:06 AM --- --- --- --- --- --- --- --- --- LE * = measured from ground surface Environmental Controls Monitoring Semiannual Report September 2025 through March 2026 South Starter Landfill (Permit No. 3620-INDUS) Appendix B Laboratory Reports, Data Validation Checklists, and Chain -of -Custody Forms Data Validation Checklist Facility/Site Allen Steam Station State NC Location/Sample IDs SSLF-CD1B, SSLF-LCS1 Duke Central Lab • Groundwater Suface Water r r J26020414 3/10/2026 3/11/2026 3/30/2026 17 Other References: National Functional Guidelines for Organic/Inorganic Superfund Methods Data Review (USEPA 2020) Guidance on Environmental Data Verification and Data Validation (USEPA 2002) Radiochemical Data Verification and Validation (MARLAP Manual Volume I: Chapter 8, 2004) -noSample Receipt and Chain of Custody 0 ❑ ❑ 1) Do the sample IDs and laboratory analyses recorded on the Chain of Custody match the sample IDs and analyses listed in the laboratory package? 21 ❑ a) Do the dates and times of sampling listed on the Chain of Custody match the laboratory report? 21 ❑ ❑ 2) Is the sample temperature upon receipt at the laboratory recorded on the Chain of Custody or sample receipt form? 21 ❑ ❑ a) Is the sample temperature upon receipt less than 6 degrees Celsius? If NO, then: ❑ ❑ 0 I) Was the presence of wet ice noted in the cooler? OR ❑ ❑ 0 II) Were the samples collected less than two hours prior to receipt at the lab? 0 ❑ ❑ 3) Was the proper sample preservation used, confirmed, and documented on the Chain of Custody and/or sample receipt form? ❑ 0 ❑ 4) Are there any special notes, exceptions, and/or anomalies listed on the Chain of Custody, sample receipt form, or laboratory report? ❑ 111 ❑ 5) Was the transfer of custody of the samples properly documented and traceable through signature, date, and time by all persons who relinquished and/or received - custody of the samples? Quality Control 6) Was the holding time for preparation and/or analysis met for each parameter? ❑ ❑ 17 a) Total Alkalinity, Bicarbonate Alkalinity, and Carbonate Alkalinity: Analyzed within 14 days of collection 21 ❑ ❑ b) Bromide, Chloride, Fluoride, and Sulfate (Anions): Analyzed within 28 days of collection ❑ ❑ 17 c) Sulfide: Analyzed within 7 days of collection 21 ❑ ❑ d) Total Organic Carbon (TOC) and/or Nitrate -Nitrite: Analyzed within 28 days of collection ❑ ❑ 0 e) Total Phosphorus (TP) and Dissolved Phosphorus: Analyzed within 28 days of collection ❑ ❑ 0 f) Hexavalent Chromium and Dissolved Hexavalent Chromium: Analyzed within 24 hours (unpreserved) / 28 days (preserved) of collection 21 ❑ ❑ g) Mercury and Dissolved Mercury: Analyzed within 28 days of collection (preserved) 21 ❑ ❑ h) Total Metals and Dissolved Metals: Analyzed within 180 days of collection 0 ❑ ❑ I) Total Suspended Solids (TSS) and/or Total Dissolved Solids (TDS): Analyzed within 7 days of collection ❑ ❑ 21 )) Radionuclides: Analyzed within 180 days of collection ❑ ❑ 21 k) Methane: Analyzed within 14 days (preserved) / 7 days (unpreserved) of collection ❑ ❑ 21 1) Oil and Grease: Analyzed within 28 days of collection 21 ❑ ❑ 7) Are there any qualifiers assigned by the laboratory and if so, are the qualifier definitions provided? 21 ❑ ❑ 8) Method Blank- Were any parameters detected in the laboratory method blank(s)? 21 ❑ ❑ a) If YES, were any target analyses detected in the samples at concentrations less than ten times the method blank concentration? ❑ 0 ❑ 9) Laboratory Control Sample (LCS) - Were any parameters flagged by the lab as being outside the limits of control in the associated LCS? ❑ a) If YES, was the parameter recovery less than 50 percent or greater than 150 percent? ❑ Ell b) Were the same parameters detected in the samples? 21 ❑ ❑ 10) Matrix Spike Sample (MS/MSD) -Did the laboratory provide matrix spike results? If so, then: 21 ❑ ❑ I a) Was the original sample spiked a project sample? If so, then: I 0 21 ❑ b) Were any parameters flagged by the lab as being outside the limits of control in the associated matrix spike sample? Yes No N/A Batch Quality Assurance/Quality Control (continued) p ❑ ❑ 11) Laboratory Duplicate Sample -Did the laboratory provide lab duplicate sample results? If so, then: ❑ 0 a) Was the sample analyzed as a laboratory duplicate a project sample? If so, then: ❑ ❑ p b) Were any parameters flagged by the lab as being outside the limits of control in the laboratory duplicate sample? ❑ ❑ p 12) Field Duplicate Sample - Is the relative percent difference between the parent and field duplicate sample results greater than 35 percent? p ❑ 13) FIeId/Equipment/Trip Blanks- Were any parameters detected in the associated field, equipment, and/or trip blanks? I] ❑ ❑ a) If yes, were any target analytes detected in the samples at a concentration less than ten times the Field/Equipment/Trip Blank concentration? p ❑ ❑ 14) Were initial and continuing calibration blank information within acceptable criteria per the lab report? ❑ 0 ❑ 15) Were any reporting limits for diluted, non -detect results greater than the screening criteria? ❑ ❑ p 16) Radionuclides: Are quality control sample results provided? ❑ ❑ 0 a) Are any results flagged or qualified? ❑ ❑ 0 b) Are Uncertainty, Minimum Detectable Concentration (MDC), and Tracer and/or Carver %Recoveries provided for each sample? Lab Qualifiers: B2 - Target analyte was detected in Method/Prep Blank(s) at a concentration greater than %the reporting limit but less than the reporting limit. Analyte concentration in sample is valid and may be used for compliance purposes. 1 - Analyte detected above the MDL, but below the RL; analyte concentration should be considered an estimate. Validation Qualifiers: R - Result is unusable. The sample result is rejected due to serious deficiencies in meeting quality control criteria; the analyte may or may not be present in the sample. 1 - Value is estimated. The result is below the reporting limit or potentially biased based on data validation. U-Analyte was analyzed for but not detected above the minimum detectable concentration (MDC) or method detection limit (MDL). B- Target analyte detected in the method blank and in the sample at a concentration less than 10x the blank concentration. • Lithium (0.00436 mg/L) was detected in the Method Blank (132); Lithium was also detected in the samples at concentrations less than 10x the blank concentration. • Boron (0.03 mg/L) and Lithium (0.005 mg/L) were detected in the Field Blank; Lithium was also detected in the samples at concentrations less than 10x the blank concentration. Review Determination: ❑ Usable 3 Usable with Required Actions ❑ Unusable Initials/Signatures: Date: Data Quality Reviewer REB 4/9/2026 Technical Lead cis 4/9/2026 �dmt, DUKE Analytical Laboratory " ENERGY.. 13339 Hagers Ferry Road Huntersville, NC 28078-7929 McGuire Nuclear Complex - MG03A2 Phone:980-875-5245 Fax:980-875-4349 Order Summary Report Order Number: J26020414 Project Name: ALLEN - SOUTH STARTER LANDFILL Task Code: LF Customer Name(s): C Murphy, B Moeller, D Obrien, J Stowe,Connor Z Customer Address: Allen Steam Station 253 Plant Allen Road Belmont, NC 28012 Lab Contact: Peggy Kendall Phone: 980-875-5848 Report Authorized By: i#Date: 3/30/2026 (Signature) it Peggy endall Program Comments: Please contact the Program Manager (Peggy Kendall) with any questions regarding this report. Data Flags & Calculations: Page 1 of 19 Any analytical tests or individual analytes within a test flagged with a Qualifier indicate a deviation from the method quality system or quality control requirement. The qualifier description is found at the end of the Certificate of Analysis (sample results) under the qualifiers heading. All results are reported on a dry weight basis unless otherwise noted. Subcontracted data included on the Duke Certificate of Analysis is to be used as information only. Certified vendor results can be found in the subcontracted lab final report. Duke Energy Analytical Laboratory subcontracts analyses to other vendor laboratories that have been qualified by Duke Energy to perform these analyses except where noted. Data Package: This data package includes analytical results that are applicable only to the samples described in this narrative. An estimation of the uncertainty of measurement for the results in the report is available upon request. This report shall not be reproduced, except in full, without the written consent of the Analytical Laboratory. Please contact the Analytical laboratory with any questions. The order of individual sections within this report is as follows: Job Summary Report, Sample Identification, Technical Validation of Data Package, Analytical Laboratory Certificate of Analysis, Analytical Laboratory QC Reports, Sub -contracted Laboratory Results, Customer Specific Data Sheets, Reports & Documentation, Customer Database Entries, Test Case Narratives, Chain of Custody (COC) Certification: The Analytical Laboratory holds the following State Certifications : North Carolina (DENR) Certificate #248, South Carolina (DHEC) Laboratory ID # 99005. Contact the Analytical Laboratory for definitive information about the certification status of specific methods. Sample ID's & Descriptions: Page 2 of 19 Sample ID Plant/Station Collection Date and Time Collected By Sample Description 2026003774 ALLEN 10-Mar-26 10:10 AM Connor Zahora ALN SSLF-CD1 B 2026003776 ALLEN 10-Mar-26 10:20 AM Connor Zahora ALN SSLF-LCS1 2026003777 ALLEN 10-Mar-26 10:00 AM Connor Zahora ALN FB-20260310-1000 3 Total Samples Page 3 of 19 Technical Validation Review Checklist: COC and .pdf report are in agreement with sample totals ❑� Yes ❑ No and analyses (compliance programs and procedures). All Results are less than the laboratory reporting limits. ❑ Yes No All laboratory QA/QC requirements are acceptable. Yes ❑ No Report Sections Included: ❑� Job Summary Report ❑d Sample Identification ❑d Technical Validation of Data Package ❑d Analytical Laboratory Certificate of Analysis ❑� Analytical Laboratory QC Report ❑ Sub -contracted Laboratory Results ❑ Customer Specific Data Sheets, Reports, & Documentation ❑ Customer Database Entries ❑d Chain of Custody ❑d Electronic Data Deliverable (EDD) Sent Separately Reviewed By: Peggy Kendall Date: 3/30/2026 Certificate of Laboratory Analysis Page 4 of 19 This report shall not be reproduced, except in full. Order # J26020414 Site: ALN SSLF-CD1 B Sample #: 2026003774 Collection Date: 03/10/2026 10:10 AM Loc code: ALN SSLF-CD1 B Matrix: GW RCRA Analyte Result Units Qualifiers RDL MDL INORGANIC IONS BY IC - Q26030222 Chloride 63 mg/L 1 0.015 Fluoride 0.04 U mg/L 0.1 0.04 Nitrate 0.51 mg/L 0.1 0.04 Nitrate as N 0.12 mg-N/L 0.023 0.023 Sulfate 22 mg/L 1 0.041 MERCURY (COLD VAPOR) IN WATER - Q26030343 Mercury (Hg) 0.05 J ug/L 0.05 0.01 TOTAL RECOVERABLE METALS BY ICP (DISSOLVED) - Q26030254 Zinc (Zn) 0.006 J mg/L 0.015 0.0011 TOTAL RECOVERABLE METALS BY ICP - Q26030258 Barium (Ba) 0.232 mg/L 0.005 0.0011 Boron (B) 0.370 mg/L 0.05 0.0046 Calcium (Ca) 25.3 mg/L 0.05 0.0124 Iron (Fe) 0.015 mg/L 0.01 0.0033 Lithium (Li) 0.009 mg/L B2 0.005 0.0027 Magnesium (Mg) 7.98 mg/L 0.02 0.0039 Manganese (Mn) 0.111 mg/L 0.005 0.0007 Total Hardness (Ca and Mg) 96.0 mg/L 0.19 0.19 (CaCO3) Zinc (Zn) 0.006 J mg/L 0.015 0.0011 TOTAL RECOVERABLE METALS BY ICP-MS (DISSOLVED) - Q26030262 Beryllium (Be) 0.3106 U ug/L 1 0.3106 Cadmium (Cd) 0.062 J ug/L 1 0.0403 Chromium (Cr) 3.13 ug/L 1 0.2894 Copper (Cu) 1.91 ug/L 1 0.1994 Lead (Pb) 0.0579 U ug/L 1 0.0579 Nickel (Ni) 1.78 ug/L 1 0.1004 Silver (Ag) 0.0521 U ug/L 1 0.0521 DF Method Analysis Date/Time Analyst 10 EPA 9056A 03/11/2026 09:55 BGN9034 1 EPA 9056A 03/11/2026 09:55 BGN9034 1 EPA 9056A 03/11/2026 09:55 BGN9034 1 EPA 9056A 03/11/2026 09:55 BGN9034 10 EPA 9056A 03/11/2026 09:55 BGN9034 1 EPA 7470A 03/16/2026 11:02 SNEGLIA 1 SW 601OD 03/24/2026 11:53 DDAUZVA 1 SW 601OD 03/20/2026 11:59 SNEGLIA 1 SW 601OD 03/20/2026 11:59 SNEGLIA 1 SW 601OD 03/20/2026 11:59 SNEGLIA 1 SW 601OD 03/20/2026 11:59 SNEGLIA 1 SW 601OD 03/20/2026 11:59 SNEGLIA 1 SW 601OD 03/20/2026 11:59 SNEGLIA 1 SW 601OD 03/20/2026 11:59 SNEGLIA 1 SW 601OD 03/20/2026 11:59 SNEGLIA 1 SW 601OD 03/20/2026 11:59 SNEGLIA 1 SW 6020B 03/17/2026 03:29 MHALL3 1 SW 6020E 03/17/2026 03:29 MHALL3 1 SW 6020B 03/17/2026 03:29 MHALL3 1 SW 6020E 03/17/2026 03:29 MHALL3 1 SW 6020E 03/17/2026 03:29 MHALL3 1 SW 6020E 03/17/2026 03:29 MHALL3 1 SW 6020B 03/17/2026 03:29 MHALL3 Certificate of Laboratory Analysis Page 5 of 19 This report shall not be reproduced, except in full. Order # J26020414 Site: ALN SSLF-CD1 B Collection Date: 03/10/2026 10:10 AM Loc code: ALN SSLF-CD1 B Sample #: Matrix: 2026003774 GW RCRA Analyte Result Units Qualifiers RDL MDL DF Method Analysis Date/Time Analyst TOTAL RECOVERABLE METALS BY ICP-MS - Q26030265 Antimony (Sb) 0.1259 U ug/L 1 0.1259 1 SW 6020B 03/18/2026 15:50 MHALL3 Arsenic (As) 0.168 U ug/L 1 0.168 1 SW 6020E 03/18/2026 15:50 MHALL3 Beryllium (Be) 0.3106 U ug/L 1 0.3106 1 SW 6020B 03/18/2026 15:50 MHALL3 Cadmium (Cd) 0.053 J ug/L 1 0.0403 1 SW 6020E 03/18/2026 15:50 MHALL3 Chromium (Cr) 3.30 ug/L 1 0.2894 1 SW 6020E 03/18/2026 15:50 MHALL3 Cobalt (Co) 1.40 ug/L 1 0.1287 1 SW 6020E 03/18/2026 15:50 MHALL3 Copper (Cu) 0.924 J ug/L 1 0.1994 1 SW 6020B 03/18/2026 15:50 MHALL3 Lead (Pb) 0.0579 U ug/L 1 0.0579 1 SW 6020E 03/18/2026 15:50 MHALL3 Molybdenum (Mo) 0.1066 U ug/L 1 0.1066 1 SW 6020B 03/18/2026 15:50 MHALL3 Nickel (Ni) 1.75 ug/L 1 0.1004 1 SW 6020E 03/18/2026 15:50 MHALL3 Selenium (Se) 0.737 J ug/L 1 0.2052 1 SW 6020E 03/18/2026 15:50 MHALL3 Silver (Ag) 0.0521 U ug/L 1 0.0521 1 SW 6020B 03/18/2026 15:50 MHALL3 Thallium (TI) Low Level 0.047 J ug/L 0.2 0.0326 1 SW 6020E 03/18/2026 15:50 MHALL3 Vanadium (V) 0.668 J ug/L 1 0.1119 1 SW 6020B 03/18/2026 15:50 MHALL3 TOTAL DISSOLVED SOLIDS - Q26030233 TDS 233 mg/L 25 25 1 SM2540C 03/11/202614:47 LELL107 Certificate of Laboratory Analysis Page 6 of 19 This report shall not be reproduced, except in full. Order # J26020414 Site: ALN SSLF-LCS1 Sample #: 2026003776 Collection Date: 03/10/2026 10:20 AM Loc code: ALN SSLF-LCS1 Matrix: GW RCRA Analyte Result Units Qualifiers RDL MDL DF INORGANIC IONS BY IC - 026030222 Chloride 16 mg/L Fluoride 0.08 J mg/L Nitrate 1.2 mg/L Nitrate as N 0.27 mg-N/L Sulfate 680 mg/L MERCURY (COLD VAPOR) IN WATER - Q26030343 Mercury (Hg) 0.01 J ug/L TOTAL RECOVERABLE METALS BY ICP - Q26030258 Barium (Ba) 0.108 mg/L Boron (B) 1.71 mg/L Calcium (Ca) 287 mg/L Iron (Fe) 1.16 mg/L Lithium (Li) 0.016 mg/L B2 Magnesium (Mg) 42.5 mg/L Manganese (Mn) 0.240 mg/L Zinc (Zn) 0.007 J mg/L TOTAL RECOVERABLE METALS BY ICP-MS - Q26030265 Antimony (Sb) 0.961 J ug/L Arsenic (As) 3.16 ug/L Beryllium (Be) 0.3106 U ug/L Cadmium (Cd) 0.108 J ug/L Chromium (Cr) 1.35 J ug/L Cobalt (Co) 0.977 J ug/L Copper (Cu) 8.09 ug/L Lead (Pb) 1.11 J ug/L Molybdenum (Mo) 219 ug/L Nickel (Ni) 4.07 ug/L Selenium (Se) 736 ug/L Silver (Ag) 0.0521 U ug/L Thallium (TI) Low Level 0.222 J ug/L Vanadium (V) 10.2 ug/L TOTAL DISSOLVED SOLIDS - Q26030233 TDS 1330 mg/L Method Analysis Date/Time Analyst 0.5 0.015 5 EPA 9056A 03/11/2026 10:16 BGN9034 0.5 0.04 5 EPA 9056A 03/11/2026 10:16 BGN9034 0.5 0.04 5 EPA 9056A 03/11/2026 10:16 BGN9034 0.115 0.115 5 EPA 9056A 03/11/2026 10:16 BGN9034 10 0.041 100 EPA 9056A 03/11/2026 10:16 BGN9034 0.05 0.01 1 EPA 7470A 03/16/2026 11:10 SNEGLIA 0.005 0.0011 1 SW 601 OD 03/20/2026 09:26 SNEGLIA 0.05 0.0046 1 SW 601 OD 03/20/2026 09:26 SNEGLIA 0.5 0.0124 10 SW 601 OD 03/20/2026 09:26 SNEGLIA 0.01 0.0033 1 SW 601 OD 03/20/2026 09:26 SNEGLIA 0.005 0.0027 1 SW 601 OD 03/20/2026 09:26 SNEGLIA 0.02 0.0039 1 SW 601 OD 03/20/2026 09:26 SNEGLIA 0.005 0.0007 1 SW 601 OD 03/20/2026 09:26 SNEGLIA 0.015 0.0011 1 SW 601 OD 03/20/2026 09:26 SNEGLIA 2 0.1259 2 SW 6020B 03/18/2026 17:44 MHALL3 2 0.168 2 SW 6020E 03/18/2026 17:44 MHALL3 2 0.3106 2 SW 6020B 03/18/2026 17:44 MHALL3 2 0.0403 2 SW 6020B 03/18/2026 17:44 MHALL3 2 0.2894 2 SW 6020E 03/18/2026 17:44 MHALL3 2 0.1287 2 SW 6020E 03/18/2026 17:44 MHALL3 2 0.1994 2 SW 6020B 03/18/2026 17:44 MHALL3 2 0.0579 2 SW 6020E 03/18/2026 17:44 MHALL3 2 0.1066 2 SW 6020E 03/18/2026 17:44 MHALL3 2 0.1004 2 SW 6020B 03/18/2026 17:44 MHALL3 2 0.2052 2 SW 6020E 03/18/2026 17:44 MHALL3 2 0.0521 2 SW 6020B 03/18/2026 17:44 MHALL3 0.4 0.0326 2 SW 6020E 03/18/2026 17:44 MHALL3 2 0.1119 2 SW 6020B 03/18/2026 17:44 MHALL3 25 25 1 SM2540C 03/11/202614:47 LELL107 Certificate of Laboratory Analysis Page 7 of 19 This report shall not be reproduced, except in full. Order # J26020414 Site: ALN FB-20260310-1000 Field Blank Sample #: 2026003777 Collection Date: 03/10/2026 10:00 AM Loc code: ALN QA Matrix: GW RCRA Analyte Result Units Qualifiers RDL MDL DF INORGANIC IONS BY IC - 026030222 Chloride 0.015 U mg/L Fluoride 0.04 U mg/L Nitrate 0.04 U mg/L Nitrate as N 0.023 U mg-N/L Sulfate 0.041 U mg/L MERCURY (COLD VAPOR) IN WATER - Q26030343 Mercury (Hg) 0.01 U ug/L TOTAL RECOVERABLE METALS BY ICP - Q26030258 Barium (Ba) 0.0011 U mg/L Boron (B) 0.03 J mg/L Calcium (Ca) 0.0124 U mg/L Iron (Fe) 0.0033 U mg/L Lithium (Li) 0.005 mg/L B2 Magnesium (Mg) 0.0039 U mg/L Manganese (Mn) 0.0007 U mg/L Zinc (Zn) 0.0011 U mg/L TOTAL RECOVERABLE METALS BY ICP-MS - Q26030265 Antimony (Sb) 0.1259 U ug/L Arsenic (As) 0.168 U ug/L Beryllium (Be) 0.3106 U ug/L Cadmium (Cd) 0.0403 U ug/L Chromium (Cr) 0.2894 U ug/L Cobalt (Co) 0.1287 U ug/L Copper (Cu) 0.1994 U ug/L Lead (Pb) 0.0579 U ug/L Molybdenum (Mo) 0.1066 U ug/L Nickel (Ni) 0.1004 U ug/L Selenium (Se) 0.2052 U ug/L Silver (Ag) 0.0521 U ug/L Thallium (TI) Low Level 0.0326 U ug/L Vanadium (V) 0.1119 U ug/L Method Analysis Date/Time Analyst 0.1 0.015 1 EPA 9056A 03/11/2026 07:52 BGN9034 0.1 0.04 1 EPA 9056A 03/11/2026 07:52 BGN9034 0.1 0.04 1 EPA 9056A 03/11/2026 07:52 BGN9034 0.023 0.023 1 EPA 9056A 03/11/2026 07:52 BGN9034 0.1 0.041 1 EPA 9056A 03/11/2026 07:52 BGN9034 0.05 0.01 1 EPA 7470A 03/16/2026 11:18 SNEGLIA 0.005 0.0011 1 SW 601OD 03/20/2026 11:59 SNEGLIA 0.05 0.0046 1 SW 601OD 03/20/2026 11:59 SNEGLIA 0.05 0.0124 1 SW 601OD 03/20/2026 11:59 SNEGLIA 0.01 0.0033 1 SW 601OD 03/20/2026 11:59 SNEGLIA 0.005 0.0027 1 SW 601OD 03/20/2026 11:59 SNEGLIA 0.02 0.0039 1 SW 601OD 03/20/2026 11:59 SNEGLIA 0.005 0.0007 1 SW 601OD 03/20/2026 11:59 SNEGLIA 0.015 0.0011 1 SW 601OD 03/20/2026 11:59 SNEGLIA 1 0.1259 1 SW 6020B 03/18/2026 15:59 MHALL3 1 0.168 1 SW 6020E 03/18/2026 15:59 MHALL3 1 0.3106 1 SW 6020B 03/18/2026 15:59 MHALL3 1 0.0403 1 SW 6020B 03/18/2026 15:59 MHALL3 1 0.2894 1 SW 6020E 03/18/2026 15:59 MHALL3 1 0.1287 1 SW 6020E 03/18/2026 15:59 MHALL3 1 0.1994 1 SW 6020B 03/18/2026 15:59 MHALL3 1 0.0579 1 SW 6020E 03/18/2026 15:59 MHALL3 1 0.1066 1 SW 6020E 03/18/2026 15:59 MHALL3 1 0.1004 1 SW 6020B 03/18/2026 15:59 MHALL3 1 0.2052 1 SW 6020E 03/18/2026 15:59 MHALL3 1 0.0521 1 SW 6020B 03/18/2026 15:59 MHALL3 0.2 0.0326 1 SW 6020E 03/18/2026 15:59 MHALL3 1 0.1119 1 SW 6020B 03/18/2026 15:59 MHALL3 Certificate of Laboratory Analysis Page 8 of 19 This report shall not be reproduced, except in full. Order # J26020414 Qualifiers: B2 Target analyte was detected in Method/Prep Blank(s) at a concentration greater than '/2 the reporting limit but less than the reporting limit. Analyte concentration in sample is valid and may be used for compliance purposes. J Analyte detected above the MDL, but below the RL. Analyte concentration should be considered an estimate. Certificate of Laboratory Analysis Page 9 of 19 This report shall not be reproduced, except in full. Order # J26020414 Level II QC Summary Q26030222 Dionex INORGANIC IONS BY IC Blank # 1 Parameter Measured Final Units Dil MDL RDL Relative Concentration Qualifier Chloride 0 0 mg/L 1 0.015 0.1 < MDL Fluoride 0 0 mg/L 1 0.04 0.1 < MDL Nitrate 0 0 mg/L 1 0.04 0.1 < MDL Sulfate 0 0 mg/L 1 0.041 0.1 < MDL LCS # 1 Parameter Measured Final Units Dil MDL Spike % Recovery LCL UCL Qualifier Chloride 5.1 5.1 mg/L 1 0.015 5 102 80 120 Fluoride 4.83 4.83 mg/L 1 0.04 5 96.7 80 120 Nitrate 5.24 5.24 mg/L 1 0.04 5 105 80 120 Sulfate 5.2 5.2 mg/L 1 0.041 5 104 80 120 MS # 1 Parent Sample: J26020411 -- 2026003765 Parameter Measured Final Units Dil MDL Spike % Recovery LCL UCL Qualifier Chloride 7.72 7.72 mg/L 1 0.015 5 101 80 120 Fluoride 4.95 4.95 mg/L 1 0.04 5 97.6 80 120 Nitrate 6.76 6.76 mg/L 1 0.04 5 103 80 120 Sulfate 7.88 7.88 mg/L 1 0.041 5 99.2 80 120 MSD # 1 Parent Sample: J26020411 -- 2026003765 Parameter Measured Final Units Dil MDL Spike % Recovery LCL UCL RPD Qualifier Chloride 7.69 7.69 mg/L 1 0.015 5 100 80 120 0.493 Fluoride 4.92 4.92 mg/L 1 0.04 5 96.9 80 120 0.649 Nitrate 6.71 6.71 mg/L 1 0.04 5 102 80 120 0.743 Sulfate 7.86 7.86 mg/L 1 0.041 5 98.8 80 120 0.254 Certificate of Laboratory Analysis Page 10 of 19 This report shall not be reproduced, except in full. Order # J26020414 Level II QC Summary Q26030343 HG 7470 MERCURY (COLD VAPOR) IN WATER Blank # 1 Parameter Measured Final Units Dil MDL RDL Relative Concentration Qualifier Mercury (Hg) -0.002 -0.002 ug/L 1 0.01 0.05 < MDL Blank # 2 Parameter Measured Final Units Dil MDL RDL Relative Concentration Qualifier Mercury (Hg) -0.02 -0.02 ug/L 1 0.01 0.05 < MDL Blank # 3 Parameter Measured Final Units Dil MDL RDL Relative Concentration Qualifier Mercury (Hg) -0.025 -0.025 ug/L 1 0.01 0.05 < MDL Blank # 4 Parameter Measured Final Units Dil MDL RDL Relative Concentration Qualifier Mercury (Hg) -0.009 -0.009 ug/L 1 0.01 0.05 < MDL LCS # 1 Parameter Measured Final Units Dil MDL Spike % Recovery LCL UCL Qualifier Mercury (Hg) 2.04 2.04 ug/L 1 0.01 2 102 85 115 LCS # 2 Parameter Measured Final Units Dil MDL Spike % Recovery LCL UCL Qualifier Mercury (Hg) 2.04 2.04 ug/L 1 0.01 2 102 85 115 LCS # 3 Parameter Measured Final Units Dil MDL Spike % Recovery LCL UCL Qualifier Mercury (Hg) 2.03 2.03 ug/L 1 0.01 2 102 85 115 MS # I Parent Sample: J26020411 -- 2026003765 Parameter Measured Final Units Dil MDL Spike % Recovery LCL UCL Qualifier Mercury (Hg) 1.12 1.12 ug/L 1 0.01 1 112 75 125 MSD # I Parent Sample: J26020411 -- 2026003765 Parameter Measured Final Units Dil MDL Spike % Recovery LCL UCL RPD Qualifier Mercury (Hg) 1.1 1.1 ug/L 1 0.01 1 110 75 125 1.26 MS # 2 Parent Sample: J26020414 -- 2026003776 Parameter Measured Final Units Dil MDL Spike % Recovery LCL UCL Qualifier Mercury (Hg) 1.1 1.1 ug/L 1 0.01 1 109 75 125 MSD # 2 Parent Sample: J26020414 -- 2026003776 Parameter Measured Final Units Dil MDL Spike % Recovery LCL UCL RPD Qualifier Mercury (Hg) 1.08 1.08 ug/L 1 0.01 1 107 75 125 1.86 Certificate of Laboratory Analysis Page 11 of 19 This report shall not be reproduced, except in full. Order # J26020414 Level II QC Summary Q26030343 HG 7470 MERCURY (COLD VAPOR) IN WATER lU G`E°#; MSD # 3 MS # 4 MSD # 4 Parameter Measured Final Mercury (Hg) 1.03 1.03 Parameter Measured Final Mercury (Hg) 1.04 1.04 Parameter Measured Final Mercury (Hg) 0.994 0.994 Parameter Measured Final Mercury (Hg) 1 1 Parent Sample: J26030216 -- 2026005323 Units Dil MDL Spike % Recovery LCL UCL ug/L 1 0.01 1 103 75 125 Parent Sample: J26030216 -- 2026005323 Units Dil MDL Spike % Recovery LCL UCL RPD ug/L 1 0.01 1 104 75 125 1.26 Parent Sample: J26030216 -- 2026005333 Units Dil MDL Spike % Recovery LCL UCL ug/L 1 0.01 1 99.3 75 125 Parent Sample: J26030216 -- 2026005333 Units Dil MDL Spike % Recovery LCL UCL RPD ug/L 1 0.01 1 99.9 75 125 0.602 Qualifier Qualifier Qualifier Qualifier Certificate of Laboratory Analysis Page 12 of 19 This report shall not be reproduced, except in full. Order # J26020414 Level II QC Summary Q26030254 ICP_DIS_TRM TOTAL RECOVERABLE METALS BY ICP (DISSOLVED) Blank # 1 LCS # 1 Parameter Measured Final Zinc (Zn) 0.000154 0.000154 Parameter Measured Final Zinc (Zn) 4.55 4.55 LCSD # 1 Parameter Measured Final Zinc (Zn) 4.65 4.65 Units Dil MDL RDL Relative Concentration mg/L 1 0.0011 0.015 < MDL Units Dil MDL Spike % Recovery LCL UCL mg/L 1 0.0011 5 91.1 80 120 Units Dil MDL Spike % Recovery LCL UCL mg/L 1 0.0011 5 92.9 80 120 Qualifier Qualifier RPD Qualifier 2 Certificate of Laboratory Analysis Page 13 of 19 This report shall not be reproduced, except in full. Order # J26020414 Level II QC Summary Q26030258 ICP_TRM TOTAL RECOVERABLE METALS BY ICP Blank # 1 Parameter Measured Final Units Dil MDL RDL Relative Concentration Barium (Ba) -0.000247 -0.000247 mg/L 1 0.0011 0.005 < MDL Boron (B) 0.00145 0.00145 mg/L 1 0.0046 0.05 < MDL Calcium (Ca) 0.000725 0.000725 mg/L 1 0.0124 0.05 < MDL Iron (Fe) 0.00224 0.00224 mg/L 1 0.0033 0.01 < MDL Lithium (Li) 0.00436 0.00436 mg/L 1 0.0027 0.005 > MDL Magnesium (Mg) 0.000031 0.000031 mg/L 1 0.0039 0.02 < MDL Manganese (Mn) 0.000258 0.000258 mg/L 1 0.0007 0.005 < MDL Zinc (Zn) 0.00184 0.00184 mg/L 1 0.0011 0.015 > MDL LCS # 1 Parameter Measured Final Units Dil MDL Spike % Recovery LCL UCL Barium (Ba) 5.16 5.16 mg/L 1 0.0011 5 103 80 120 Boron (B) 5.09 5.09 mg/L 1 0.0046 5 102 80 120 Calcium (Ca) 5.06 5.06 mg/L 1 0.0124 5 101 80 120 Iron (Fe) 5.13 5.13 mg/L 1 0.0033 5 103 80 120 Lithium (Li) 5.13 5.13 mg/L 1 0.0027 5 103 80 120 Magnesium (Mg) 5.12 5.12 mg/L 1 0.0039 5 102 80 120 Manganese (Mn) 5.11 5.11 mg/L 1 0.0007 5 102 80 120 Zinc (Zn) 5.1 5.1 mg/L 1 0.0011 5 102 80 120 MS # 1 Parent Sample: J26020411 -- 2026003765 Parameter Measured Final Units Dil MDL Spike % Recovery LCL UCL Barium (Ba) 5.28 5.28 mg/L 1 0.0011 5 105 75 125 Boron (B) 5.19 5.19 mg/L 1 0.0046 5 104 75 125 Calcium (Ca) 13.8 13.8 mg/L 1 0.0124 5 99.8 75 125 Iron (Fe) 5.27 5.27 mg/L 1 0.0033 5 105 75 125 Lithium (Li) 5.19 5.19 mg/L 1 0.0027 5 104 75 125 Magnesium (Mg) 7.18 7.18 mg/L 1 0.0039 5 102 75 125 Manganese (Mn) 5.22 5.22 mg/L 1 0.0007 5 104 75 125 Zinc (Zn) 5.18 5.18 mg/L 1 0.0011 5 103 75 125 MSD # 1 Parent Sample: J26020411 -- 2026003765 Parameter Measured Final Units Dil MDL Spike % Recovery LCL UCL RPD Barium (Ba) 5.24 5.24 mg/L 1 0.0011 5 104 75 125 0.76 Boron (B) 5.21 5.21 mg/L 1 0.0046 5 104 75 125 0.385 Calcium (Ca) 14 14 mg/L 1 0.0124 5 104 75 125 1.44 Iron (Fe) 5.23 5.23 mg/L 1 0.0033 5 105 75 125 0.762 Lithium (Li) 5.18 5.18 mg/L 1 0.0027 5 104 75 125 0.193 Magnesium (Mg) 7.19 7.19 mg/L 1 0.0039 5 102 75 125 0.139 Manganese (Mn) 5.18 5.18 mg/L 1 0.0007 5 103 75 125 0.769 Qualifier B2 Qualifier Qualifier Qualifier Certificate of Laboratory Analysis Page 14 of 19 This report shall not be reproduced, except in full. Order # J26020414 Level II QC Summary Q26030258 ICP_TRM TOTAL RECOVERABLE METALS BY ICP MSD # 1 Parent Sample: J26020411 -- 2026003765 Parameter Measured Final Units Dil MDL Spike % Recovery LCL UCL RPD Qualifier Zinc (Zn) 5.16 5.16 mg/L 1 0.0011 5 103 75 125 0.387 Qualifiers: B2 Target analyte was detected in Method/Prep Blank(s) at a concentration greater than '/2 the reporting limit but less than the reporting limit. Analyte concentration in sample is valid and may be used for compliance purposes. Certificate of Laboratory Analysis Page 15 of 19 This report shall not be reproduced, except in full. Order # J26020414 Level II QC Summary Q26030262 IMS_DIS_TRM TOTAL RECOVERABLE METALS BY ICP-MS (DISSOLVED) Blank # 1 LCS # 1 Parameter Measured Final Units Dil MDL RDL Relative Concentration Qualifier Beryllium (Be) 0.004 0.004 ug/L 1 0.3106 1 < MDL Cadmium (Cd) 0.004 0.004 ug/L 1 0.0403 1 < MDL Chromium (Cr) 0.023 0.023 ug/L 1 0.2894 1 < MDL Copper (Cu) -0.031 -0.031 ug/L 1 0.1994 1 < MDL Lead (Pb) 0 0 ug/L 1 0.0579 1 < MDL Nickel (Ni) 0.009 0.009 ug/L 1 0.1004 1 < MDL Silver (Ag) 0.001 0.001 ug/L 1 0.0521 1 < MDL Parameter Measured Final Units Dil MDL Spike % Recovery LCL UCL Qualifier Beryllium (Be) 47.8 47.8 ug/L 1 0.3106 50 95.7 80 120 Cadmium (Cd) 49.2 49.2 ug/L 1 0.0403 50 98.3 80 120 Chromium (Cr) 49.6 49.6 ug/L 1 0.2894 50 99.3 80 120 Copper (Cu) 50.6 50.6 ug/L 1 0.1994 50 101 80 120 Lead (Pb) 52.2 52.2 ug/L 1 0.0579 50 104 80 120 Nickel (Ni) 50.3 50.3 ug/L 1 0.1004 50 101 80 120 Silver (Ag) 53.8 53.8 ug/L 1 0.0521 50 108 80 120 LCSD # 1 Parameter Measured Final Units Dil MDL Spike % Recovery LCL UCL RPD Qualifier Beryllium (Be) 49.7 49.7 ug/L 1 0.3106 50 99.4 80 120 3.81 Cadmium (Cd) 50.7 50.7 ug/L 1 0.0403 50 101 80 120 3.18 Chromium (Cr) 51 51 ug/L 1 0.2894 50 102 80 120 2.68 Copper (Cu) 53.1 53.1 ug/L 1 0.1994 50 106 80 120 4.72 Lead (Pb) 53.8 53.8 ug/L 1 0.0579 50 108 80 120 3.13 Nickel (Ni) 52.3 52.3 ug/L 1 0.1004 50 105 80 120 4 Silver(Ag) 55.7 55.7 ug/L 1 0.0521 50 111 80 120 3.64 Certificate of Laboratory Analysis Page 16 of 19 This report shall not be reproduced, except in full. Order # J26020414 Level II QC Summary Q26030265 IMS_TRM TOTAL RECOVERABLE METALS BY ICP-MS Blank # 1 Parameter Measured Final Units Dil MDL RDL Relative Concentration Antimony (Sb) -0.064 -0.064 ug/L 1 0.1259 1 < MDL Arsenic (As) 0.017 0.017 ug/L 1 0.168 1 < MDL Beryllium (Be) 0.016 0.016 ug/L 1 0.3106 1 < MDL Cadmium (Cd) -0.001 -0.001 ug/L 1 0.0403 1 < MDL Chromium (Cr) 0.017 0.017 ug/L 1 0.2894 1 < MDL Cobalt (Co) -0.004 -0.004 ug/L 1 0.1287 1 < MDL Copper (Cu) 0.022 0.022 ug/L 1 0.1994 1 < MDL Lead (Pb) -0.004 -0.004 ug/L 1 0.0579 1 < MDL Molybdenum (Mo) 0.021 0.021 ug/L 1 0.1066 1 < MDL Nickel (Ni) -0.008 -0.008 ug/L 1 0.1004 1 < MDL Selenium (Se) 0 0 ug/L 1 0.2052 1 < MDL Silver (Ag) 0.002 0.002 ug/L 1 0.0521 1 < MDL Thallium (TI) Low Level 0.017 0.017 ug/L 1 0.0326 0.2 < MDL Vanadium (V) -0.008 -0.008 ug/L 1 0.1119 1 < MDL LCS # 1 Parameter Measured Final Units Dil MDL Spike % Recovery LCL UCL Antimony (Sb) 56.5 56.5 ug/L 1 0.1259 50 113 80 120 Arsenic (As) 52.8 52.8 ug/L 1 0.168 50 106 80 120 Beryllium (Be) 53.1 53.1 ug/L 1 0.3106 50 106 80 120 Cadmium (Cd) 55 55 ug/L 1 0.0403 50 110 80 120 Chromium (Cr) 53.2 53.2 ug/L 1 0.2894 50 106 80 120 Cobalt (Co) 54.1 54.1 ug/L 1 0.1287 50 108 80 120 Copper (Cu) 54.4 54.4 ug/L 1 0.1994 50 109 80 120 Lead (Pb) 55.5 55.5 ug/L 1 0.0579 50 111 80 120 Molybdenum (Mo) 55 55 ug/L 1 0.1066 50 110 80 120 Nickel (Ni) 54.1 54.1 ug/L 1 0.1004 50 108 80 120 Selenium (Se) 53 53 ug/L 1 0.2052 50 106 80 120 Silver(Ag) 54.5 54.5 ug/L 1 0.0521 50 109 80 120 Thallium (TI) Low Level 51.1 51.1 ug/L 1 0.0326 50 102 80 120 Vanadium (V) 54.3 54.3 ug/L 1 0.1119 50 109 80 120 MS # 1 Parent Sample: J26020411 -- 2026003766 Parameter Measured Final Units Dil MDL Spike % Recovery LCL UCL Antimony (Sb) 27.5 55 ug/L 2 0.1259 50 109 75 125 Arsenic (As) 27.1 54.2 ug/L 2 0.168 50 105 75 125 Beryllium (Be) 24.8 49.6 ug/L 2 0.3106 50 99.1 75 125 Cadmium (Cd) 26 52 ug/L 2 0.0403 50 104 75 125 Chromium (Cr) 25.9 51.8 ug/L 2 0.2894 50 103 75 125 Cobalt (Co) 40 80.1 ug/L 2 0.1287 50 100 75 125 Qualifier Qualifier Qualifier Certificate of Laboratory Analysis This report shall not be reproduced, except in full. Order # J26020414 Level II QC Summary Q26030265 IMS_TRM TOTAL RECOVERABLE METALS BY ICP-MS MS # 1 Parameter Measured Final Units Dil MDL Spike Copper (Cu) 26.7 53.5 ug/L 2 0.1994 50 Lead (Pb) 26.9 53.8 ug/L 2 0.0579 50 Molybdenum (Mo) 170 341 ug/L 2 0.1066 50 Nickel (Ni) 37 74 ug/L 2 0.1004 50 Selenium (Se) 168 336 ug/L 2 0.2052 50 Silver (Ag) 25 50 ug/L 2 0.0521 50 Thallium (TI) Low Level 22.9 45.9 ug/L 2 0.0326 50 Vanadium (V) 27.5 55 ug/L 2 0.1119 50 MSD # 1 Parameter Measured Final Units Dil MDL Spike Antimony (Sb) 27.8 55.7 ug/L 2 0.1259 50 Arsenic (As) 27.5 55 ug/L 2 0.168 50 Beryllium (Be) 25.2 50.5 ug/L 2 0.3106 50 Cadmium (Cd) 26.4 52.8 ug/L 2 0.0403 50 Chromium (Cr) 26.2 52.5 ug/L 2 0.2894 50 Cobalt (Co) 40.9 81.8 ug/L 2 0.1287 50 Copper (Cu) 27.3 54.7 ug/L 2 0.1994 50 Lead (Pb) 27.2 54.4 ug/L 2 0.0579 50 Molybdenum (Mo) 171 343 ug/L 2 0.1066 50 Nickel (Ni) 38 76 ug/L 2 0.1004 50 Selenium (Se) 169 337 ug/L 2 0.2052 50 Silver (Ag) 25.6 51.3 ug/L 2 0.0521 50 Thallium (TI) Low Level 23.4 46.8 ug/L 2 0.0326 50 Vanadium (V) 28 56.1 ug/L 2 0.1119 50 Page 17 of 19 Parent Sample: J26020411 -- 2026003766 % Recovery LCL UCL 99.7 75 125 108 75 125 107 75 125 101 75 125 113 75 125 100 75 125 89.9 75 125 107 75 125 Parent Sample: J26020411 -- 2026003766 % Recovery LCL UCL RPD 111 75 125 1.19 107 75 125 1.45 101 75 125 1.78 105 75 125 1.61 104 75 125 1.39 103 75 125 2.07 102 75 125 2.2 109 75 125 1.14 110 75 125 0.495 104 75 125 2.65 115 75 125 0.377 103 75 125 2.47 91.8 75 125 2.05 110 75 125 1.87 Qualifier Qualifier Certificate of Laboratory Analysis Page 18 of 19 This report shall not be reproduced, except in full. Order # J26020414 Level II QC Summary Q26030233 TDS TOTAL DISSOLVED SOLIDS Blank # 1 Blank # 2 Parameter Measured Final TDS 0 Parameter Measured Final TDS 0 Duplicate # 1 Parameter Measured Final TDS 806 Duplicate # 2 Parameter Measured Final TDS 351 LCS # 1 LCS # 2 Parameter Measured Final TDS 491 Parameter Measured Final TDS 489 Units Dil MDL RDL Relative Concentration Qualifier mg/L 1 25 25 < MDL Units Dil MDL RDL Relative Concentration Qualifier mg/L 1 25 25 < MDL Parent Sample: J26020003 -- 2026002211 Units Dil MDL RPD Qualifier mg/L 1 25 1.36 Parent Sample: J26030319 -- 2026005863 Units Dil MDL RPD Qualifier mg/L 1 25 0.285 Units Dil MDL Spike % Recovery LCL UCL Qualifier mg/L 1 25 500 98.2 90 110 Units Dil MDL Spike % Recovery LCL UCL Qualifier mg/L 1 25 500 97.8 90 110 ('DUKE Duke Energy Analytical Laboratory I 1 Mmlcod MG03nz Ferry Rd (Bmltlfng7as) i 13 339 Hag:r iOrdar#~ J26020414 ENERGY Rumen-11., N.t. 29378 + iLogs.dB II y pal ns-sus _ _ _ _ _ _ _ _ _ _ _ co EZ.IZ 4ansaogs ._._._._._.� Project Name ALLEN SOUTH STARTER LANDFILL Phone No: !Vendor $ PERMIT 3020-INDUS Client COURTNEY MURPHY, BRYAN MOELLER. DEE TO O'BRIEN, JOSH STOWE, CONNOR ZAHORA f ! Operating Unit: AS00 Process:NGRDWTR Account: i L.._.._--_.._.. ------- Project: AAS000415 Activity ID: Facility ID" G Program / EOuiS Task Code: ALW Sub-ProgramlTask Code: Sample Description or ID ALN_SSLF-CD1B ALN=66EfSZLL Ch ALN_SSLF-LCS1 ALN_FB- Zu4 o3t0- 1000 CHAIN OF CUSTODY RECORD AND ANALYSIS REQUEST FORM -------------------------------------------ao.i - ical L-aeo:aio --use o�i--------------------------- ------------------------------------------ Page 19 of 19 Matrix WATER _ Page t_of_1_ s.mP�.. o,�.,�.o�, r,.m NC_Xsc_ DISTRIBUTION SAMPLE PROGRAM ORIGINAL to LAB, COPY to CLIENT Ground Water X_ NPDES_ Drinking Water_ UST_ 1I RCRA Waste _.._.._.._ _.._.. Cooler _�mp10�.._..__.._.-_.._.._--_--_.._.._._.._--_----._.._.._.._.._-.-.._.._.._.._--_.._--_ '• Filtration (0.45 um) b Unfiltered b Filtered i Preservative ICE I ICE Container Volume (mL) 500 300 500 260 ContalnerType HDPE PET PET HDPE Customer to complete all appropriate non -shaded areas. 3-10-U (wo .&wArp2zAl"Ol,+ 3 -0- Zd 10 zU Co *cm 24Pv" 3-to-iL 1000 Cewwa ?At4ou ' (Metals Prep - TRIM) / Cl, F, 12 (ICP - SW 6010D) Ba, B, NO3-N y rc o Ca, Fe, Li, Mg, Mn, Zn (8) / Hg (SW 7470A) I (48-Hr Hold MS SW6010D Zn / SW 6 m c (IMS - SW 6020B) Sb, Time), Cu, Pb,Ni,Cr, Cu, b, i, Ag V Tn As, Be, Cd, Cr, Co, Cu, Pb, Mo, Ni, Se, Ag, SO4F _ TI LL V 14 X 1 i 1 1 4 X -t 4. t t X 1 1 1 3 X 1 1 2 By ri((%- me Date/Time Atu�74�- uaei ime ,1Gw U`ai%�aCG�/ m u v a v � c o. c Requested TurnaroundRellnquishatl 21 Days 14 Days X Relinquished By Date/Time Accepted Dat&M Relinquished By Data/Time Accepted By: Datenime ; Q, wDays E m — N r � m -7 Seal/Locked By DatelTime Sealed/Lock Opened By Date/Thins, Comments EQUIS EDD Required o 0 'Other [For ALN_SSLF-CD1B and ALN_SSLF-SW7, include Total Hardness in ICP_TRM metals list] U -Add Cost Will Apply