HomeMy WebLinkAbout3620_DukeAllen_SSLF_ECMR_FID2822423_20260630(> DUKE
ENERGY.
June 30, 2026
North Carolina Department of Environmental Quality
Division of Waste Management
Solid Waste Section
2090 U.S. Highway 70
Swannanoa, NC 28778
Attn: Ms. Sarah Moutos (submitted electronically)
Re: Environmental Controls Monitoring Semi -Annual Report
South Starter Landfill
Permit No.: 3620-INDUS-2022
Allen Steam Station
Gaston County, North Carolina
Dear Ms. Moutos:
525 S. Tryon St.
Mail Code: DEP-36A
Charlotte NC, 28202
In accordance with the Environmental Control Monitoring Plan (ECMP) Revision 2, Duke Energy is providing
the results of the 2026 first semi-annual leachate, construction drain, surface water sampling and leak
detection system (LDS) monitoring for the Allen Steam Station South Starter Landfill (SSLF) (Permit No.:
3620-INDUS-2022), located near Belmont, in Gaston County, North Carolina.
On March 10, 2026, samples were collected from the SSLF leachate collection system (LCS) and
construction drain. No sample was able to be collected from the surface water location since it was dry.
The samples were collected by Duke Energy personnel and analyzed by the Duke Energy Analytical
Laboratory. A summary of monitoring results can be found in the attached ECMR. The parameters tested
are not bound by state groundwater or surface water standards. All laboratory analytical and field results
are provided in the appendices of the Report.
Allen Steam Station's SSLF is sampled semi-annually, typically during the months of March and September.
The next landfill sampling event is scheduled for September 2026 with documentation to follow.
If you need additional information regarding this submittal do not hesitate to email or call me at
Courtney.Murphy@duke-energy.com or (704) 382-7171.
Respectfully,
dwh1w1fl"
Courtney W. Murphy, P.G.
Environmental Services
www.duke-energy.com Page 1 of 2
Attachments: Environmental Controls Monitoring Semiannual Report — September 2025 through March
2026 (SynTerra, June 30, 2026)
cc (via e-mail): Jordan Russ, NCDEQ
Elizabeth Werner, NCDEQ
Sherri Stanley, NCDEQ
Ben Dawkins, Duke Energy
Sheila Westcott, Duke Energy
Kenneth McKinney, Duke Energy
Charlie Smith, Duke Energy
Tyler Hardin, Duke Energy
Kim Witt, Duke Energy
www.duke-energy.com Page 2 of 2
NC DEQ Division of Waste Management Environmental Monitoring
Solid Waste Section Reporting Form
Note: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents
are available for inspection and examination by any person upon request (NC General Statute 132-6).
Instructions:
Prepare one form for each individually monitored unit. List complete permit IDs lie, 0101-MSWLF-1972, 0101-CDLF-1962, etc)
Type or print legibly.
Groundwater: Attach a notification table with values that attain or exceed NC 2L groundwater standards and/or other applicable groundwater
protection standards.
Surface Water: Attach a notification table with values that attain or exceed NC 2B surface water standards.
Landfill Gas: Attach a notification table of any methane gas values that attain or exceed explosive gas levels.
Notification tables must include a preliminary analysis of the cause and significance of each value, as known or suspected.
Submit electronic or hardcopy signed and sealed form, tables, and Electronic Data Deliverables to the Section Hydrogeologist assigned to the
facility. Hard copies can be mailed to: Environmental Compliance Branch, NCDEQ-DWM, Solid Waste Section, 1646 Mail Service Center,
Raleigh, NC 27699-1646
Solid Waste Monitoring Data Submittal Information
NAME of ENTITY submitting data (ie, laboratory, consultant, facility owner):
Duke Energy (owner)
CONTACT: Courtney Murphy 704-382-7171 courtne mur h duke-ener com
Name: y p y Phone: E-mail: y P y@ gy
Permit ID (i.e., 101 0-MSWLF-1 980) NC Landfill Rule:
Facility Name: * List all that apply * County (.0500 or .1600) Sample Collection Date(s)
Duke Allen 3620-INDUS .0500 March 10, 2026
South Starter Landfill Gaston
Environmental Status: (Check all that apply)
❑ Initial/Baseline Monitoring W1 Detection Monitoring ❑ Assessment Monitoring ❑ Corrective Action
Type of Data submitted: (Check all that apply)
Groundwater monitoring data from monitoring wells ❑ Methane gas monitoring data
Groundwater monitoring data from private water supply wells F7 Corrective action data (specify)
✓ Leachate monitoring data
Surface water monitoring data 9✓ Other (specify) Construction Drain Discharge
Notification Attached?
MNO. No groundwater, surface water, or landfill gas standards were exceeded.
YES - a notification of values exceeding a groundwater or surface water standard is attached. It includes a list of groundwater and surface water
monitoring points, dates, analytical values, NC 2L groundwater standard, NC 2B surface water standard or NC Solid Waste GWPS; and a
preliminary analysis of the cause and significance of any exceedance.
❑ YES - a notification of values exceeding an explosive methane gas limit is attached. It includes the methane monitoring points, dates, sample
values and explosive methane gas limits.
CERTIFICATION
To the best of my knowledge, the information reported, and statements made on this data submittal and attachments are true and correct.
Furthermore, I have attached complete notification of any sampling values meeting or exceeding groundwater or surface water standards or
explosive gas levels, and a preliminary analysis of the cause and significance of concentrations exceeding standards. I am aware that there
are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment.
Courtney W. Murphy, P.G. Lead Environmental Specialist
Facility Representative Name (Print) Title
6/30/2026 Affix NC Licensed/ Professional Geologist or PE Seal
Signature Date N
``,`CrAR
.•• O
525 S. Tryon St, Charlotte, NC 28202 oQ-.�,�G�NS
Facility Representative Address Z = f+ :y
#F-0566 203
NC Geological Corporation Number or NC PE Firm License Number Gj•:' ,>
O FOL OG ••• Q
(if applicable effective May 1, 2009) '. �/ Q- Revised
EY"M����`�' 10101/2025
Environmental Controls Monitoring
Semiannual Report
September 2025 through March 2026
Allen Steam Station
South Starter Landfill (Permit No. 3620-INDUS)
Gaston County, North Carolina
DUKE
ENERGY
CAROLINAS
PREPARED FOR:
Duke Energy Carolinas, LLC
June 30, 2026
Christopher Suttell
Project Manager, NC L.G. 2426
Hanna Cunningham
Staff Scientist
Scott Spinner
Senior Peer Reviewer
Environmental Controls Monitoring Semiannual Report September 2025 through March 2026
South Starter Landfill (Permit No. 3620-INDUS)
Table of Contents
1.0
Background...................................................................................................................................1
1JSite
Description................................................................................................................................... 1
1.1.1 South Starter Landfill.................................................................................................................... 1
1.1.2 Leachate Basin............................................................................................................................. 2
1.1.3 Construction Drain....................................................................................................................... 2
1.1.4 Surface Water Management.........................................................................................................2
1.2
Summary of Site Geology and Hydrology............................................................................................... 3
2.0
Monitoring, Sampling, and Analysis Locations and Methods............................................................... 4
2.1
Leak Detection System Monitoring....................................................................................................... 4
22
Leachate Sampling and Analysis............................................................................................................ 4
23
Construction Drain Outlet Sampling and Analysis................................................................................... 4
2.4
Surface Water Sampling and Analysis.................................................................................................... 5
3.0
Monitoring, Sampling, and Analysis Results...................................................................................... 6
3.1
Leak Detection System Monitoring Results............................................................................................6
3.2
Leachate and Analytical Results............................................................................................................ 6
3.3
Construction Drain Outlet Analytical Results.......................................................................................... 6
3.4
Surface Water Analytical Results........................................................................................................... 7
4.0
References....................................................................................................................................8
Page i
Environmental Controls Monitoring Semiannual Report
South Starter Landfill (Permit No. 3620-INDUS)
September 2025 through March 2026
List of Drawings
Drawing 1 Site Location Map
Drawing 2 Monitoring Locations
List of Tables
Table 1 Leak Detection System Monitoring Results —South Starter Landfill
Table 2 Leachate Analytical Results — March 10, 2026
Table 3 Construction Drain Outlet Analytical Results — March 10, 2026
List of Appendices
Appendix A Field Sampling Forms
Appendix B Laboratory Reports, Data Validation Checklists, and Chain -of -Custody Forms
Page ii
Environmental Controls Monitoring Semiannual Report September 2025 through March 2026
South Starter Landfill (Permit No. 3620-INDUS)
1.0 Background
This Environmental Controls Monitoring Semiannual Report documents monitoring results pertaining to the
South Starter Landfill (SSLF or landfill; Permit No. 3620-INDUS) located at the Duke Energy Carolinas, LLC (Duke
Energy) Allen Steam Station (Allen, Station, or Site). The monitoring results in this report are for the period of
September 2025 through March 2026.
The Environmental Controls Monitoring Plan (ECMP) establishes locations and procedures for monitoring the
early detection of solid waste or leachate potentially released to the environment from the SSLF. The
Environmental Control Monitoring Plan, Revision 2 (ECMP, Revision 2; SynTerra, 2025) was submitted to the
North Carolina Department of Environmental Quality (NCDEQ) Division of Waste Management (DWM) on May
23, 2025, and approved by the NCDEQ DWM on June 16, 2025. The March 2026 monitoring event and this
report comply with the ECMP, Revision 2 (SynTerra, 2025).
The landfill is designed and constructed in accordance with North Carolina General Statute (G.S.) 130A-295.4 for
Combustion Products Landfills as discussed in the ECMP, Revision 2 (SynTerra, 2025). The procedures
established in the ECMP, Revision 2 and the associated monitoring documented in this report are intended to
satisfy the water quality monitoring plan required by North Carolina Administrative Code (NCAC), Title 15A,
Subchapter 13B .0504(c)(8)(D) in accordance with G.S. 130A-295.4(c).
1.1 Site Description
A summarized description of the SSLF is provided below. A more detailed description of the SSLF and
the Site is presented in the ECMP, Revision 2 (SynTerra, 2025). The Station is no longer used for power
generation and is now in the process of being decommissioned.
The SSLF [in accordance with G.S. 130A-295.4(b)] is constructed with a base liner system that includes
a primary and secondary geomembrane liner. The primary and secondary liners are separated by a
geocomposite drainage layer to create a leak detection layer. The geocomposite provides enough
capacity to convey liquid that enters the leak detection layer to a sump area (lowest elevation in an
area of the liner system), where it is collected for removal by mechanical pumping. Removal of liquid
from the leak detection layer, in addition to the combination of a geosynthetic clay liner (GCL) and
compacted soil liner beneath the secondary liner, reduces the potential for liquid to enter the
environment. The quantity of liquid removed from the leak detection layer is measured and recorded.
1.1.1 South Starter Landfill
The approximately 22-acre SSLF is located primarily south of the Active Ash Basin (AAB) but
partially overlaps the southeast portion of the AAB (Drawing 1). The SSLF is bound by the AAB to
the north, upland areas to the south and west, and lowland areas and the Catawba River (Lake
Wylie) to the east (Drawing 2).
Most of the waste intended for placement throughout the life of the landfill consists of coal
combustion residuals (CCR), predominantly fly ash and bottom ash. The approved waste streams
are provided in the Operations Plan — Revision 1, Allen Steam Station South Starter Landfill
Permit No. 3620-INDUS) (Operations Plan; AECOM, 2025). Leachate from the SSLF is primarily
conveyed via force main to the on -Site wastewater treatment system (WWTS); however, a
secondary conveyance to the Leachate Basin via force main is available for temporary storage
when the WWTS is off line. Leachate conveyance from the Leachate Basin is described in Section
1.1.2.
Page 1
Environmental Controls Monitoring Semiannual Report September 2025 through March 2026
South Starter Landfill (Permit No. 3620-INDUS)
The SSLF received a Permit to Operate on July 22, 2025, and began receiving CCR on July 30,
2025.
1.1.2 Leachate Basin
The approximately 3-acre Leachate Basin is located within the northwestern portion of the AAB
and is bounded by the Retired Ash Basin (RAB) to the north, AAB to the east and south, and
upland areas to the west (Drawing 1 and Drawing 2). Leachate Basin monitoring results are
included in a separate environmental controls monitoring report.
Leachate from the Leachate Basin is pumped via force main to the on -Site WWTS, where it is
comingled with other wastewater for treatment. Flows from the on -Site WWTS are discharged
to the Catawba River (Lake Wylie) through Outfall 002 in accordance with National Pollutant
Discharge Elimination System (NPDES) Permit NC0004979 (Drawing 2).
In a letter dated October 2, 2024, the NCDEQ granted interim approval for operation of a
temporary pumping system and to place CCR as interim cover in the Leachate Basin. Final
approval of Leachate Basin operation was granted on November 14, 2023, after the permanent
pumping system was in place and upon receipt of the NCDEQ's approval of the Leachate Basin
Construction Certification Report, Volumes 1 through 3 (FID 1776828, FID 1818490, and FID
1820954), which contained construction quality assurance information. The Leachate Basin
began operating on November 14, 2023, receiving leachate from the North Starter Landfill
(NSLF). The Leachate Basin began to receive leachate from the SSLF upon approval of the Permit
to Operate received July 22, 2025; however, leachate from the SSLF is primarily routed directly
to the on -Site WWTS.
1.13 Construction Drain
A gravity flow construction drain was installed beneath the SSLF for the purpose of maintaining
groundwater elevations in the area at levels at least 4 feet below the composite liner system.
The SSLF construction drain is composed of a 6-inch high -density polyethylene (HDPE) DR-11
perforated piping network placed beneath the composite liner system of the SSLF (Drawing 2).
The pipes are surrounded by 6 inches of stone with a geotextile wrap and convey collected
groundwater for discharge via 6-inch solid HDPE DR-11 piping. The construction drain was
completed in May 2024 and has been operational since that time.
The construction drain outlet sample location, ALN-SSLF-CD1B, is at the terminus of discharge
pipes within a wet well structure adjacent to the northeastern corner of the SSLF (Drawing 2).
Construction drain discharge from the wet well is pumped to either the AAB Polishing Pond or a
lined equalization basin within the AAB temporarily before being collected and managed
through the on -Site WWTS and discharged to the Catawba River (Lake Wylie) through Outfall
002 (Drawing 2) in accordance with NPDES Permit NC0004979.
1.1.4 Surface Water Management
The SSLF was designed to provide separation of contact water from non -contact stormwater.
Contact stormwater is managed as leachate. Non -contact stormwater runoff from the landfill is
conveyed to the perimeter channel network via a series of tack -on berms, benches, and down
chutes.
Page 2
Environmental Controls Monitoring Semiannual Report September 2025 through March 2026
South Starter Landfill (Permit No. 3620-INDUS)
No surface water streams are upgradient of the SSLF. An intermittent stream originates
immediately downgradient of the SSLF disposal area. When flow is sufficient, surface water is
sampled at one location (ALN-SSLF-SW1) within the intermittent stream down and side -gradient
of the SSLF (Drawing 2).
1,2 Summary of Site Geology and Hydrology
The groundwater system at Allen is consistent with the regolith-fractured rock system and is
characterized as an unconfined, interconnected aquifer system indicative of the Piedmont
physiographic province in which the Site is contained. The groundwater system at the Site is divided
into the following three flow layers to distinguish the interconnected groundwater system: the shallow
flow zone, the deep flow zone (transition zone), and the bedrock flow zone.
The AAB, RAB, Distribution of Residual Solids (DORS) Fills (which includes two ash storage areas and
two structural fills), RAB Ash Landfill, NSLF, and SSLF are contained within former perennial stream
valleys (the flow compartment) (Drawing 1). Groundwater within the flow compartment is a flow -
through system. In the vicinity of the SSLF, groundwater enters the system from the upgradient end in
the western portion of Duke Energy property boundary and flows laterally beneath the central
portions of the AAB and SSLF and downward near the AAB dam. Beyond the dam, groundwater flows
toward and discharges to the Catawba River (Lake Wylie).
A groundwater divide is present in the vicinity of the SSLF to the west and south of the SSLF . The
groundwater divide is upgradient of the SSLF and roughly follows topography along South Point Road
(to the west) and Reese Wilson Road (to the south) (Drawing 1). The topographically controlled flow
direction provides natural hydraulic control of groundwater in the vicinity of the SSLF, ash basins, and
adjacent sources within the flow compartment.
Page 3
Environmental Controls Monitoring Semiannual Report September 2025 through March 2026
South Starter Landfill (Permit No. 3620-INDUS)
2.0 Monitoring, Sampling, and Analysis Locations and Methods
2.1 Leak Detection System Monitoring
Leak detection monitoring occurs in the vicinity of the landfill sump at ALN-SSLF-LDS1 (Drawing 2).
Performance of the leak detection system (LDS) is determined by the average monthly quantity of
liquid removed from the leak detection layer. Each leak detection discharge pump is equipped with a
pump totalizer (flow meter). The flow meter rates were monitored and recorded as defined in the
Operations Plan (AECOM, 2025).
Leak detection monitoring results are summarized in Section 3.1.
2.2 Leachate Sampling and Analysis
A discrete leachate sample was collected from the leachate collection discharge in the vicinity of the
landfill sump at ALN-SSLF-LCS1 on March 10, 2026. The leachate sample location is shown on
Drawing 2. Duke Energy personnel collected samples and documented the sampling in accordance
with procedures provided in Duke Energy's Landfill Sample Collection Guideline (SynTerra, 2023,
Appendix 1).
Copies of the field sampling forms are included in Appendix A. The parameters and constituents
reported were sampled in accordance with Table 1 of the approved ECMP, Revision 2 (SynTerra, 2025).
The Duke Energy Analytical Laboratory (North Carolina Laboratory Certification No. 248) performed
sample analysis for the constituents listed in the ECMP, Revision 2 (SynTerra, 2023. The laboratory
report and chain -of -custody (COC) forms are included in Appendix B.
The leachate samples were measured for the following parameters in the field:
• pH, specific conductivity, temperature, dissolved oxygen, and oxidation-reduction potential
using a water quality meter
• Turbidity using a turbidity meter
The leachate samples were analyzed in the laboratory for the following constituents:
• Barium, boron, calcium, iron, lithium, magnesium, manganese, and zinc using U.S.
Environmental Protection Agency (USEPA) Method 6010D
• Antimony, arsenic, beryllium, cadmium, chromium, cobalt, copper, lead, molybdenum, nickel,
selenium, silver, thallium, and vanadium using USEPA Method 6020B
• Chloride, fluoride, nitrate (as nitrogen), and sulfate using USEPA Method 9056A
• Mercury using USEPA Method 7470A
• Total dissolved solids using Standard Method (SM) 2540C
Leachate field parameters and analytical results are summarized in Section 3.2.
2.3 Construction Drain Outlet Sampling and Analysis
A construction drain outlet sample was collected from ALN-SSLF-CD1B on March 10, 2026 (Drawing 2).
Page 4
Environmental Controls Monitoring Semiannual Report September 2025 through March 2026
South Starter Landfill (Permit No. 3620-INDUS)
Copies of the field calibration and sampling forms are included in Appendix A. The parameters and
constituents reported were sampled in accordance with Table 1 of the approved ECMP, Revision 2
(SynTerra, 2025). The Duke Energy Analytical Laboratory performed sample analysis for the
constituents listed in the ECMP, Revision 2 (SynTerra, 2023). The laboratory report and COC forms are
included in Appendix B.
The construction drain outlet sample was measured for the same set of parameters and constituents
as the leachate samples (Section 2.2) and the following additional parameters and constituents:
• Beryllium (dissolved), cadmium (dissolved), chromium (dissolved), copper (dissolved), lead
(dissolved), nickel (dissolved), and silver (dissolved) using USEPA Method 6020B
• Total hardness and zinc (dissolved) using USEPA Method 6010D
Construction drain outlet field parameters and analytical results are summarized in Section 3.3.
2.4 Surface Water Sampling and Analysis
Surface water is sampled from an intermittent stream that flows downgradient and side -gradient of
the SSLF to the south from sample location ALN-SSLF-SW1 (Drawing 2). However, a surface water
sample was not collected during the March 2026 sampling event because of insufficient flow within
the stream channel.
Page 5
Environmental Controls Monitoring Semiannual Report September 2025 through March 2026
South Starter Landfill (Permit No. 3620-INDUS)
3.0 Monitoring, Sampling, and Analysis Results
3.1 Leak Detection System Monitoring Results
Leakage rates were less than the initial response leakage rate (IRLR) and action leakage rate (ALR)
during the reporting period. An average daily leakage rate is calculated for the operational SSLF each
month and compared to the IRLR and ALR for the landfill LDS as defined in the Operations Plan
(AECOM, 2025).
Average daily leakage rates for the SSLF were calculated as follows:
1. Calculate the monthly total volume pumped (gallons):
monthly volume pumped (gallons) = current month total flow meter reading — preceding month
total flow meter reading
2. Calculate the average daily leakage rate [gallons per acre per day (gpad)]:
average daily leakage rate (gpad) = monthly volume pumped (gallons) - landfill cell area (acres)
monitoring duration (days)
The LDS monitoring results for location ALN-SSLF-LDS1 are included in Table 1. The LDS leakage rate
data collection details are kept with on -Site records.
No leakage rates or notable variances in the data outside of the normal operating range for the landfill
were observed during the monitoring period.
3.2 Leachate and Analytical Results
Leachate analytical results are not compared to surface water or groundwater quality standards. The
leachate analytical results for ALN-SSLF-LCS1 are included in Table 2.
As normal laboratory practice, select samples were diluted to within the calibrated range of analysis.
Specific information regarding the diluted samples, including the dilution factor, is reported in the
electronic data deliverable and the laboratory analytical report. The laboratory analytical report, data
validation checklist, and COC form associated with data collected as part of this semiannual monitoring
period are included in Appendix B.
3.3 Construction Drain Outlet Analytical Results
Construction drain outlet analytical results are not compared to surface water or groundwater quality
standards. The construction drain outlet analytical results for ALN-SSLF-CD1B are included in Table 3.
The construction drain outlet sample is included in the same laboratory analytical report, data
validation checklist, and COC form as the leachate data collected as part of this semiannual monitoring
period (Appendix B).
Page 6
Environmental Controls Monitoring Semiannual Report September 2025 through March 2026
South Starter Landfill (Permit No. 3620-INDUS)
3.4 Surface Water Analytical Results
During the March 2026 sampling event, a surface water sample was not collected because of
insufficient flow within the intermittent stream channel at designated sample location ALN-SSLF-SW1;
therefore, there are no surface water analytical results to report.
Page 7
Environmental Controls Monitoring Semiannual Report September 2025 through March 2026
South Starter Landfill (Permit No. 3620-INDUS)
4.0 References
AECOM. (2021). Engineering and Facility Plan, Revision 1 — Duke Energy Carolinas, LLC., Allen Steam
Station —South Starter Landfill, Permit No. 3620-INDUS. March 26, 2021.
AECOM. (2025). Operations Plan, Revision 1 — Duke Energy Carolinas, LLC., Allen Steam Station —South
Starter Landfill, Permit No. 3620-INDUS. May 16, 2025.
SynTerra. (2023). Environmental Control Monitoring Plan, Revision 2 — Duke Energy Carolinas, LLC., Allen
Steam Station —South Starter Landfill, Permit No. 3620-INDUS. May 2025.
Page 8
Environmental Controls Monitoring Semiannual Report September 2025 through March 2026
South Starter Landfill (Permit No. 3620-INDUS)
Drawings
r)B r
v --3 ..
I r:'.r a.
- — FORMER LINED 1 sa`.I:a•',4;:
RETENTION BASIN ` ! dhc WijH,
CANAL ROAD:!
r LANDFILL
= DUKE ENERGY I
PROPERTY BOUNDARY
I FORMER
GYPSUM PAD
r/ J FALLEN STEAM STATION
DISCHARGE �� FORMER COAL
CANAL PILE AREA
r" r� =
J
,NORTHSTARTER RETIRED ASH BASIN I
LANDFILL
3619-INDUS
RETIRED ASH BASIN
AfyfN?r;•" !JokS' I ASH LANDFILL
ti7a +`♦ ` 1_ _ ^ _ 3612-INDUS
f
LEACHATE 111
BASIN
1 '
1 ASH BASIN ~
ACTIVE
LANDFILL
ASH BASIN 3621-INDUS
,
J
t
(00-
AN
x f`
SOUTH STARTER
LANDFILL-----
nk
3620-INDUS
LAO
N
6--1:Gid.3MI
NOTES:
1. BOUNDARIES PROVIDED BY DUKE ENERGY AND ARE APPROXIMATE.
2. WATER FEATURES DEPICTED WITHIN WASTE BOUNDARIES
OF THE ASH BASINS ON THE USGS TOPOGRAPHIC MAP
DO NOT REPRESENT CURRENT CONDITIONS.
3. UNITED STATES GEOLOGICAL SURVEY TOPOGRAPHIC MAP
OBTAINED FROM ESRI. LAST UPDATED OCTOBER 2025.
DUKE
ENERGY
CAROLINAS
k'
Terra
l rr.
DRAWING 1
SITE LOCATION MAP
ENVIRONMENTAL CONTROLS MONITORING SEMIANNUAL REPORT
SOUTH STARTER LANDFILL (PERMIT NO. 3620-INDUS)
SEPTEMBER 2025 THROUGH MARCH 2O26
ALLEN STEAM STATION
GASTON COUNTY, NORTH CAROLINA
�I
GASTON ' DRAWN BY: C. NORRIS DATE: 12/31/2025 GRAPHIC SCALE
COUNTY REVCHECKEE DBY: HC CUNNINGH
AM : 0PPROV6/30/2026 1000 0 (IN FEET) s000 2000
'IYPYYBCOYD.com PROJECT MANAGER: C. SUTTELL
LAYOUT NAME: DRAW1_ALLEN USGS LOCATIONjNAP_SSLF
r—
I�
Ar
.. A
LEGEND
/ 4
O CONSTRUCTION DRAIN OUTLET SAMPLING LOCATION
O LEACHATE SAMPLING LOCATION
0 • LEACHATE DETECTION SYSTEM MONITORING
• SURFACE WATER SAMPLING LOCATION
NPDES OUTFACE
j I i ❑ CONSTRUCTION DRAIN WET WELL
i /' •' I,' �,_ _ CONSTRUCTION DRAIN
of ALN—SSLF—LDS1 ALN—SSLF—CD1A —.. .6 A�' LEACHATE FORCE MAIN
�. ft . , — — — CURRENT TEMPORARY LEACHATE FORCE MAIN
- .
� � — — —LEACHATE BASIN
4 _
— — —ASH BASIN LANDFILL BOUNDARY
R r NORTH STARTER LANDFILL BOUNDARY
ALN—SSLF—LCS1 1 L — — — SOUTH STARTER LANDFILL BOUNDARY
CANAL ROAD LANDFILL BOUNDARY
O SITE FEATURES
ALN—SSLF—CD1 B — — — L — _
_ e - ' .ACTIVE ASH BASIN WASTE BOUNDARY
I i L RETIRED ASH BASIN WASTE BOUNDARY
y _ - L RETIRED ASH BASIN ASH LANDFILL WASTE BOUNDARY
DORS FILLS BOUNDARIES
DUKE ENERGY PROPERTY BOUNDARY
SURFACSTREAMEAMATER FLOW EC NRTR ODIRECTION
--- c )
I ` ' WETLAND (AMEC NRTR 2015)
/ I_ NOTES:
ALN—SSLF—SW11. THE WATERS OF THE US HAVE NOT BEEN APPROVED BY THE US ARMY CORPS OF
ENGINEERS AT THE TIME OF THE MAP CREATION. THIS MAP IS A PRELIMINARY
I
JURISDICTIONAL DETERMINATION ONLY. THE WETLANDS AND STREAMS BOUNDARIES WERE
INSET SCALE: 1" = 400' \I OBTAINED FROM AMEC FOSTER WHEELER ENVIRONMENTAL & INFRASTRUCTURE, INC.
NATURAL RESOURCE TECHNICAL REPORT FOR ALLEN STEAM STATION DATED MAY 29, 2015.
A.
-NPDES 2. BOUNDARIES PROVIDED BY DUKE ENERGY AND ARE APPROXIMATE.
3. AERIAL IMAGERY IS A COMBINATION OF DUKE ENERGY PROPELLER AERIAL PHOTOGRAPHY
'ALN-SSLF-Lost ALNSSLF-CD1A CAPTURED ON MARCH 23, 2026 AND MAXAR IMAGERY FROM ESRI CAPTURED ON MAY 28, 2024.
F �- Aw-ssLFcole 4. DRAWING HAS BEEN SET WITH A PROJECTION OF NORTH CAROLINA STATE PLANE
ALN-SSLF-LCS1 COORDINATE SYSTEM FIPS 3200 (NAD 83).
5. FOR CONSTRUCTION DRAIN DETAILS, SEE RESPECTIVE LANDFILL CONSTRUCTION QUALITY
ASSURANCE REPORTS BY WSP USA, INC.
6. DORS -DISTRIBUTION OF RESIDUAL SOLIDS
ALNSSLF-SW1 7. NPDES - NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM
8. LEACHATE FORCE MAIN ALIGNMENT PROVIDED BY AECOM ON JANUARY 7, 2026.
GRAPH IC SCALE
(' DUKE 500 0 500 1,000 DRAWING 2
ENERGY MONITORING LOCATIONS
CAROLINA UN FEET) ENVIRONMENTAL CONTROLS MONITORING SEMIANNUAL REPORT
DRAWN BY:C. NORRIS DATE: 12/31/2025 SOUTH STARTER LANDFILL(PERMIT NO. 3620-INDUS)
REVISEDBY:C.NORRIS DATE:06/30/2026 SEPTEMBER 2025 THROUGH MARCH 2O26
CHECKED BY: H. CUNNINGHAM DATE:06/30/2026 ALLEN STEAM STATION
APPROVED BY:C. SUTTELL DATE:06/30/2026
PROJECT MANAGER: C. SUTTELL GASTON COUNTY, NORTH CAROLINA
PATH: G:\OARCGIS PRO PROJECTS\DUKE_ENERGY\ALLEN\2026\ENVIRONMENTALCONTROLSMONITORINGRPT\ECMR_2026.APRX
LAYOUT NAME: DRAW2 ALLEN MONITORING LOCATIONS SSLF
Environmental Controls Monitoring Semiannual Report September 2025 through March 2026
South Starter Landfill (Permit No. 3620-INDUS)
Tables
TABLE 1
LEAK DETECTION SYSTEM MONITORING RESULTS - SOUTH STARTER LANDFILL
ENVIRONMENTAL CONTROLS MONITORING SEMIANNUAL REPORT
SOUTH STARTER LANDFILL (PERMIT NO. 3620-INDUS)
SEPTEMBER 2025 THROUGH MARCH 2O26
ALLEN STEAM STATION
DUKE ENERGY CAROLINAS, LLC, GASTON COUNTY, NORTH CAROLINA
ALN-SSLF-LSD1
MONTHLY
MONTHLY
TOTAL
AVERAGE
AVERAGE DAILY
AVERAGE DAILY
MONITORING
MONITORING
DURATION
VOLUME
VOLUME
SSLF
DAILY
LEAKAGE RATE
LEAKAGE RATE
PERIOD
(DAYS)
TOTAL
RAINFALL
PUMPED
PUMPED
AREA
LEAKAGE
EXCEEDS IRLR:
EXCEEDS ALR:
COMMENTSt
(GALLONS)'
(GALLONS)'
(ACRES)2
RATE
316 GPAD
421 GPAD
(INCHES)'
(GPAD)
(YES/NO)
(YES/NO)
LDS PUMP TOTALIZER
September 2025
30
2.38
727
9,725
22
4.33
NO
NO
LDS pump level was triggered
October 2025
31
2.62
1
9,726
0.00
NO
NO
--
November 2025
30
0.54
4
9,730
0.01
NO
NO
--
December 2025
31
1.82
753
10,483
0.97
NO
NO
LDS pump level was triggered
January 2026
31
1
10
10,493
0.01
NO
NO
--
February 2026
20
0
10
10,503
0.02
NO
NO
March 2026
31
1
17
10,520
0.02
NO
NO
Prepared by: HCC Checked by: TAW
Notes:
' Data and comments provided by Duke Energy Carolinas, LLC.
2 As presented in the Engineering and Facility Plan, Revision 1, Allen Steam Station, South Starter Landfill, Prepared by AECOM Technical Services of North Carolina, Inc., Dated: March 26, 2021.
-- no comments made
ALR- The Action Leakage Rate is 421 GPAD, as presented in the Engineering and Facility Plan - Revision 1 (AECOM, 2021).
GPAD - gallons per acre per day
IRLR- The Initial Response Leakage Rate is 316 GPAD, as presented in the Engineering and Facility Plan - Revision 1 (AECOM, 2021).
LDS - Leak Detection System
SSLF - South Starter Landfill
TABLE 2
LEACHATE ANALYTICAL RESULTS - MARCH 10, 2026
ENVIRONMENTAL CONTROLS MONITORING SEMIANNUAL REPORT
SEPTEMBER 2025 THROUGH MARCH 2O26
SOUTH STARTER LANDFILL (PERMIT NO. 3620-INDUS)
ALLEN STEAM STATION
DUKE ENERGY CAROLINAS, LLC, GASTON COUNTY, NORTH CAROLINA
Constituent
ALN SSLF-LCS1
Field Parameters
pH (S.U.)
6.9
Temperature (Deg C)
22
Specific Conductance (µmhos/cm)
1,121
Dissolved Oxygen (mg/L)
3.6
Oxidation -Reduction Potential (mV)
281
Turbidity (NTUs)
NM
Laboratory Analyses
Antimony
0.961 J
Arsenic
3.16
Barium
108
Beryllium
< 2
Boron
1,710
Cadmium
0.108 J
Calcium (mg/L)
287
Chloride (mg/L)
16
Chromium
1.351
Cobalt
0.977 J
Copper
8.09
Fluoride (mg/L)
0.081
Iron
1,160
Lead
1.11 J
Lithium
16 BJ
Magnesium (mg/L)
42.5
Manganese
240
Mercury
0.01 J
Molybdenum
219
Nickel
4.07
Nitrate (as nitrogen) (mg-N/L)
0.27
Selenium
736
Silver
< 2
Sulfate (mg/L)
680
Total Dissolved Solids (TDS) (mg/L)
1,330
Thallium
0.222 J
Vanadium
10.2
Zinc
71
Prepared by: HCC Checked by: TAW
Notes:
Analytical data presented in this table reflect the Duke Energy Biological Analytical Data Storage System (BASS) as of April 21, 2026.
Analytical results presented in micrograms per liter (µg/L) unless otherwise noted.
<- Concentration not detected at or above the adjusted reporting limit.
B- Target analyte was detected in Method/Prep Blank(s) at a concentration greater than Y2 the reporting limit but less than
the reporting limit. Analyte concentration in sample is valid and may be used for compliance purposes.
J - Value is estimated. The result is below the reporting limit or potentially biased based on data validation.
NM - not measured
S.U. - standard units
Deg C - degrees Celsius
µmhos/cm - micromhos per centimeter
mg/L- milligrams per liter
mV - millivolts
NTUs - nephelometric turbidity units
mg-N/L - milligrams nitrogen per liter
µg/L - micrograms per liter
TABLE 3
CONSTRUCTION DRAIN OUTLET ANALYTICAL RESULTS - MARCH 10, 2026
ENVIRONMENTAL CONTROLS MONITORING SEMIANNUAL REPORT
SOUTH STARTER LANDFILL (PERMIT NO. 3620-INDUS)
SEPTEMBER 2025 THROUGH MARCH 2O26
ALLEN STEAM STATION
DUKE ENERGY CAROLINAS, LLC, GASTON COUNTY, NORTH CAROLINA
Constituent
ALN-SSLF-CD1B
Field Parameters
pH (S.U.)
5.9
Temperature (Deg C)
21
Specific Conductance (µmhos/cm)
213
Dissolved Oxygen (mg/L)
5.11
Oxidation -Reduction Potential (mV)
289
Turbidity (NTUs)
1.0
Laboratory Analyses
Antimony
< 1
Arsenic
< 1
Barium
232
Beryllium
< 1
Beryllium (dissolved)
< 1
Boron
370
Cadmium
0.053 J
Cadmium (dissolved)
0.062 J
Calcium (mg/L)
25.3
Chloride (mg/L)
63
Chromium
3.3
Chromium (dissolved)
3.13
Cobalt
1.4
Copper
0.924 J
Copper (dissolved)
1.91
Fluoride (mg/L)
< 0.1
Iron
15
Lead
< 1
Lead (dissolved)
< 1
Lithium
9 BJ
Magnesium (mg/L)
7.98
Manganese
111
Mercury
0.05 J
Molybdenum
< 1
Nickel
1.75
Nickel (dissolved)
1.78
Nitrate (as nitrogen) (mg-N/L)
0.12
Selenium
0.737 J
Silver
< 1
Silver (dissolved)
< 1
Page 1 of 2
TABLE 3
CONSTRUCTION DRAIN OUTLET ANALYTICAL RESULTS - MARCH 10, 2026
ENVIRONMENTAL CONTROLS MONITORING SEMIANNUAL REPORT
SOUTH STARTER LANDFILL (PERMIT NO. 3620-INDUS)
SEPTEMBER 2025 THROUGH MARCH 2O26
ALLEN STEAM STATION
DUKE ENERGY CAROLINAS, LLC, GASTON COUNTY, NORTH CAROLINA
Constituent
ALN-SSLF-CD1B
Laboratory Analyses (Continued)
Sulfate (mg/L)
22
Total Dissolved Solids (TDS) (mg/L)
233
Total Hardness
96
Thallium
0.047 J
Vanadium
0.668 J
Zinc
6 J
Zinc (dissolved)
6 J
Prepared by: HCC Checked by: TAW
Notes:
Analytical data presented in this table reflect the Duke Energy Biological Analytical Data Storage System (BASS) as of April 21, 2026.
Analytical results presented in micrograms per liter (µg/L) unless otherwise noted.
<- Concentration not detected at or above the adjusted reporting limit.
B- Target analyte was detected in Method/Prep Blank(s) at a concentration greater than % the reporting limit but less than
the reporting limit. Analyte concentration in sample is valid and may be used for compliance purposes.
J - Value is estimated. The result is below the reporting limit or potentially biased based on data validation.
S.U. - standard units
Deg C - degrees Celsius
µmhos/cm - micromhos per centimeter
mg/L - milligrams per liter
mV - millivolts
NTUs - nephelometric turbidity units
mg-N/L - milligrams nitrogen per liter
µg/L - micrograms per liter
Page 2 of 2
Environmental Controls Monitoring Semiannual Report September 2025 through March 2026
South Starter Landfill (Permit No. 3620-INDUS)
Appendix A
Field Calibration and Sampling Forms
,Ifa6, DUKE
Z"FNERGY
Duke Energy Groundwater Sampling
Field Data Form
Well ID:
ALN_SSLF-CD1B
Date:10 Mar 2026
nny, Air
Tump:72 deg F
Site ID
ALN
Purge Method / Pump Intake Depth
Equipment Purge / --- ---
Reference Elevation
--- ---
Project Name
LF
Purge Equipment
Peristaltic pump
Initial Depth to Water
0 ft
Appearance
Clear, None
Total Volume Purged
21 g
Total Well Depth*
--- ---
Pump Condition
---
Volume of Water in Well
--- 9
Well Diameter / Well Screen Interval*
2 in / --- - --- ---
Sampler Name:
CJZ
Date and Time:
3/10/2026 10:10
Sample ID(s):
ALN_SSLF-CD1B_20260310-1010_LF
Purging Comments:
Sampling Comments:
2026003774
QAQC Sample(s):
---
Time
DTW
Flow Rate
(ml/min)
Purge
Volume
(g)
Temperature
(C)
pH
(SU)
Specific
Conductivity
(US/cm)
Dissolved
Oxygen
(mg/1)
ORP
(mV)
Turbidity
(NTU)
3/10/26 10:07 AM
---
250
0
21
5.94
213
5.11
289
1
* = measured from ground surface
,Ifa6, DUKE
Z"FNERGY
Duke Energy Groundwater Sampling
Field Data Form
Well ID:
ALN_SSLF-LCS1
Date:10 Mar 2026
nny, Air
Tump:72 deg F
Site ID
ALN
Purge Method / Pump Intake Depth
Equipment Purge / --- ---
Reference Elevation
--- ---
Project Name
LF
Purge Equipment
Grab Sample
Initial Depth to Water
0 ft
Appearance
Clear, None
Total Volume Purged
--- g
Total Well Depth*
--- ---
Pump Condition
---
Volume of Water in Well
---
Well Diameter / Well Screen Interval*
Sampler Name:
CJZ
Date and Time:
3/10/2026 10:20
Sample ID(s):
ALN_SSLF-LCS1_20260310-1020_LF
Purging Comments:
Sampling Comments:
2026003776
QAQC Sample(s):
---
Time
DTW
Flow Rate
(ml/min)
Purge
Volume
(g)
Temperature
(C)
pH
(SU)
Specific
Conductivity
(US/cm)
Dissolved
Oxygen
(mg/1)
ORP
(mV)
Turbidity
3/10/26 10:18 AM
---
500
0
22
6.85
1121
3.56
281
---
* = measured from ground surface
,Ifa6, DUKE
Z"FNERGY
Duke Energy Groundwater Sampling
Field Data Form
Well ID:
ALN_SSLF-SW1
Date:10 Mar 2026
nny, Air
Tump:72 deg F
Site ID
ALN
Purge Method / Pump Intake Depth
--- / --- ---
Reference Elevation
--- ---
Project Name
LF---
Purge Equipment
Initial Depth to Water
--- ---
Appearance
---
Total Volume Purged
--- ---
Total Well Depth*
--- ---
Pump Condition
---
Volume of Water in Well
--- ---
Well Diameter / Well Screen Interval*
2 in / --- - --- ---
Sampler Name:
CJZ
Date and Time:
---
Sample ID(s):
Well Dry
Purging Comments:
Sampling Comments:
QAQC Sample(s):
---
Time
DTW
Flow Rate
Purge
Volume
Temperature
pH
Specific
Conductivity
Dissolved
Oxygen
ORP
Turbidity
3/10/26 10:06 AM
---
---
---
---
---
---
---
---
---
LE
* = measured from ground surface
Environmental Controls Monitoring Semiannual Report September 2025 through March 2026
South Starter Landfill (Permit No. 3620-INDUS)
Appendix B
Laboratory Reports, Data Validation Checklists,
and Chain -of -Custody Forms
Data Validation Checklist
Facility/Site
Allen Steam Station
State
NC
Location/Sample IDs
SSLF-CD1B, SSLF-LCS1
Duke Central Lab
•
Groundwater
Suface Water
r
r
J26020414 3/10/2026 3/11/2026 3/30/2026
17 Other
References:
National Functional Guidelines for Organic/Inorganic Superfund Methods Data Review (USEPA 2020)
Guidance on Environmental Data Verification and Data Validation (USEPA 2002)
Radiochemical Data Verification and Validation (MARLAP Manual Volume I: Chapter 8, 2004)
-noSample
Receipt and Chain of Custody
0
❑
❑
1) Do the sample IDs and laboratory analyses recorded on the Chain of Custody match the sample IDs and analyses listed in the laboratory package?
21
❑
a) Do the dates and times of sampling listed on the Chain of Custody match the laboratory report?
21
❑
❑
2) Is the sample temperature upon receipt at the laboratory recorded on the Chain of Custody or sample receipt form?
21
❑
❑
a) Is the sample temperature upon receipt less than 6 degrees Celsius? If NO, then:
❑
❑
0
I) Was the presence of wet ice noted in the cooler? OR
❑
❑
0
II) Were the samples collected less than two hours prior to receipt at the lab?
0
❑
❑
3) Was the proper sample preservation used, confirmed, and documented on the Chain of Custody and/or sample receipt form?
❑
0
❑
4) Are there any special notes, exceptions, and/or anomalies listed on the Chain of Custody, sample receipt form, or laboratory report?
❑
111
❑
5) Was the transfer of custody of the samples properly documented and traceable through signature, date, and time by all persons who relinquished and/or received
-
custody of the samples?
Quality Control
6) Was the holding time for preparation and/or analysis met for each parameter?
❑
❑
17
a) Total Alkalinity, Bicarbonate Alkalinity, and Carbonate Alkalinity: Analyzed within 14 days of collection
21
❑
❑
b) Bromide, Chloride, Fluoride, and Sulfate (Anions): Analyzed within 28 days of collection
❑
❑
17
c) Sulfide: Analyzed within 7 days of collection
21
❑
❑
d) Total Organic Carbon (TOC) and/or Nitrate -Nitrite: Analyzed within 28 days of collection
❑
❑
0
e) Total Phosphorus (TP) and Dissolved Phosphorus: Analyzed within 28 days of collection
❑
❑
0
f) Hexavalent Chromium and Dissolved Hexavalent Chromium: Analyzed within 24 hours (unpreserved) / 28 days (preserved) of collection
21
❑
❑
g) Mercury and Dissolved Mercury: Analyzed within 28 days of collection (preserved)
21
❑
❑
h) Total Metals and Dissolved Metals: Analyzed within 180 days of collection
0
❑
❑
I) Total Suspended Solids (TSS) and/or Total Dissolved Solids (TDS): Analyzed within 7 days of collection
❑
❑
21
)) Radionuclides: Analyzed within 180 days of collection
❑
❑
21
k) Methane: Analyzed within 14 days (preserved) / 7 days (unpreserved) of collection
❑
❑
21
1) Oil and Grease: Analyzed within 28 days of collection
21
❑
❑
7) Are there any qualifiers assigned by the laboratory and if so, are the qualifier definitions provided?
21
❑
❑
8) Method Blank- Were any parameters detected in the laboratory method blank(s)?
21
❑
❑
a) If YES, were any target analyses detected in the samples at concentrations less than ten times the method blank concentration?
❑
0
❑
9) Laboratory Control Sample (LCS) - Were any parameters flagged by the lab as being outside the limits of control in the associated LCS?
❑
a) If YES, was the parameter recovery less than 50 percent or greater than 150 percent?
❑
Ell
b) Were the same parameters detected in the samples?
21
❑
❑
10) Matrix Spike Sample (MS/MSD) -Did the laboratory provide matrix spike results? If so, then:
21
❑
❑
I
a) Was the original sample spiked a project sample? If so, then:
I
0
21
❑
b) Were any parameters flagged by the lab as being outside the limits of control in the associated matrix spike sample?
Yes No N/A Batch Quality Assurance/Quality Control (continued)
p ❑ ❑ 11) Laboratory Duplicate Sample -Did the laboratory provide lab duplicate sample results? If so, then:
❑ 0 a) Was the sample analyzed as a laboratory duplicate a project sample? If so, then:
❑ ❑ p b) Were any parameters flagged by the lab as being outside the limits of control in the laboratory duplicate sample?
❑
❑ p 12) Field Duplicate Sample - Is the relative percent difference between the parent and field duplicate sample results greater than 35 percent?
p ❑ 13) FIeId/Equipment/Trip Blanks- Were any parameters detected in the associated field, equipment, and/or trip blanks?
I] ❑ ❑ a) If yes, were any target analytes detected in the samples at a concentration less than ten times the Field/Equipment/Trip Blank concentration?
p ❑ ❑ 14) Were initial and continuing calibration blank information within acceptable criteria per the lab report?
❑ 0 ❑ 15) Were any reporting limits for diluted, non -detect results greater than the screening criteria?
❑ ❑ p 16) Radionuclides: Are quality control sample results provided?
❑ ❑ 0 a) Are any results flagged or qualified?
❑ ❑ 0 b) Are Uncertainty, Minimum Detectable Concentration (MDC), and Tracer and/or Carver %Recoveries provided for each sample?
Lab Qualifiers:
B2 - Target analyte was detected in Method/Prep Blank(s) at a concentration greater than %the reporting limit but less than the reporting limit. Analyte concentration in sample is valid and
may be used for compliance purposes.
1 - Analyte detected above the MDL, but below the RL; analyte concentration should be considered an estimate.
Validation Qualifiers:
R - Result is unusable. The sample result is rejected due to serious deficiencies in meeting quality control criteria; the analyte may or may not be present in the sample.
1 - Value is estimated. The result is below the reporting limit or potentially biased based on data validation.
U-Analyte was analyzed for but not detected above the minimum detectable concentration (MDC) or method detection limit (MDL).
B- Target analyte detected in the method blank and in the sample at a concentration less than 10x the blank concentration.
• Lithium (0.00436 mg/L) was detected in the Method Blank (132); Lithium was also detected in the samples at concentrations less than 10x the blank concentration.
• Boron (0.03 mg/L) and Lithium (0.005 mg/L) were detected in the Field Blank; Lithium was also detected in the samples at concentrations less than 10x the blank concentration.
Review Determination: ❑ Usable 3 Usable with Required Actions ❑ Unusable
Initials/Signatures: Date:
Data Quality Reviewer REB 4/9/2026
Technical Lead cis 4/9/2026
�dmt, DUKE Analytical Laboratory
" ENERGY..
13339 Hagers Ferry Road
Huntersville, NC 28078-7929
McGuire Nuclear Complex - MG03A2
Phone:980-875-5245 Fax:980-875-4349
Order Summary Report
Order Number: J26020414
Project Name: ALLEN - SOUTH STARTER LANDFILL
Task Code: LF
Customer Name(s): C Murphy, B Moeller, D Obrien, J Stowe,Connor Z
Customer Address: Allen Steam Station
253 Plant Allen Road
Belmont, NC 28012
Lab Contact: Peggy Kendall Phone: 980-875-5848
Report Authorized By: i#Date: 3/30/2026
(Signature) it
Peggy endall
Program Comments:
Please contact the Program Manager (Peggy Kendall) with any questions regarding this report.
Data Flags & Calculations:
Page 1 of 19
Any analytical tests or individual analytes within a test flagged with a Qualifier indicate a deviation from the method quality
system or quality control requirement. The qualifier description is found at the end of the Certificate of Analysis (sample results)
under the qualifiers heading. All results are reported on a dry weight basis unless otherwise noted. Subcontracted data
included on the Duke Certificate of Analysis is to be used as information only. Certified vendor results can be found in the
subcontracted lab final report. Duke Energy Analytical Laboratory subcontracts analyses to other vendor laboratories that have
been qualified by Duke Energy to perform these analyses except where noted.
Data Package:
This data package includes analytical results that are applicable only to the samples described in this narrative. An estimation of
the uncertainty of measurement for the results in the report is available upon request. This report shall not be reproduced, except
in full, without the written consent of the Analytical Laboratory. Please contact the Analytical laboratory with any questions. The
order of individual sections within this report is as follows:
Job Summary Report, Sample Identification, Technical Validation of Data Package, Analytical Laboratory Certificate of Analysis,
Analytical Laboratory QC Reports, Sub -contracted Laboratory Results, Customer Specific Data Sheets, Reports &
Documentation, Customer Database Entries, Test Case Narratives, Chain of Custody (COC)
Certification:
The Analytical Laboratory holds the following State Certifications : North Carolina (DENR) Certificate #248, South Carolina
(DHEC) Laboratory ID # 99005. Contact the Analytical Laboratory for definitive information about the certification status of
specific methods.
Sample ID's & Descriptions:
Page 2 of 19
Sample ID
Plant/Station
Collection
Date and Time
Collected By
Sample Description
2026003774
ALLEN
10-Mar-26 10:10 AM
Connor Zahora
ALN SSLF-CD1 B
2026003776
ALLEN
10-Mar-26 10:20 AM
Connor Zahora
ALN SSLF-LCS1
2026003777
ALLEN
10-Mar-26 10:00 AM
Connor Zahora
ALN FB-20260310-1000
3 Total Samples
Page 3 of 19
Technical Validation Review
Checklist:
COC and .pdf report are in agreement with sample totals ❑� Yes ❑ No
and analyses (compliance programs and procedures).
All Results are less than the laboratory reporting limits. ❑ Yes No
All laboratory QA/QC requirements are acceptable.
Yes ❑ No
Report Sections Included:
❑� Job Summary Report
❑d Sample Identification
❑d Technical Validation of Data Package
❑d Analytical Laboratory Certificate of Analysis
❑� Analytical Laboratory QC Report
❑ Sub -contracted Laboratory Results
❑ Customer Specific Data Sheets, Reports, & Documentation
❑ Customer Database Entries
❑d Chain of Custody
❑d Electronic Data Deliverable (EDD) Sent Separately
Reviewed By: Peggy Kendall Date: 3/30/2026
Certificate of Laboratory Analysis Page 4 of 19
This report shall not be reproduced, except in full.
Order # J26020414
Site: ALN SSLF-CD1 B Sample #: 2026003774
Collection Date: 03/10/2026 10:10 AM Loc code: ALN SSLF-CD1 B Matrix: GW RCRA
Analyte
Result
Units
Qualifiers RDL
MDL
INORGANIC IONS BY IC - Q26030222
Chloride
63
mg/L
1
0.015
Fluoride
0.04 U
mg/L
0.1
0.04
Nitrate
0.51
mg/L
0.1
0.04
Nitrate as N
0.12
mg-N/L
0.023
0.023
Sulfate
22
mg/L
1
0.041
MERCURY (COLD VAPOR) IN WATER - Q26030343
Mercury (Hg)
0.05 J
ug/L
0.05
0.01
TOTAL RECOVERABLE METALS BY ICP (DISSOLVED)
- Q26030254
Zinc (Zn)
0.006 J
mg/L
0.015
0.0011
TOTAL RECOVERABLE METALS BY ICP -
Q26030258
Barium (Ba)
0.232
mg/L
0.005
0.0011
Boron (B)
0.370
mg/L
0.05
0.0046
Calcium (Ca)
25.3
mg/L
0.05
0.0124
Iron (Fe)
0.015
mg/L
0.01
0.0033
Lithium (Li)
0.009
mg/L
B2 0.005
0.0027
Magnesium (Mg)
7.98
mg/L
0.02
0.0039
Manganese (Mn)
0.111
mg/L
0.005
0.0007
Total Hardness (Ca and Mg)
96.0
mg/L
0.19
0.19
(CaCO3)
Zinc (Zn)
0.006 J
mg/L
0.015
0.0011
TOTAL RECOVERABLE METALS BY ICP-MS (DISSOLVED) - Q26030262
Beryllium (Be)
0.3106 U
ug/L
1
0.3106
Cadmium (Cd)
0.062 J
ug/L
1
0.0403
Chromium (Cr)
3.13
ug/L
1
0.2894
Copper (Cu)
1.91
ug/L
1
0.1994
Lead (Pb)
0.0579 U
ug/L
1
0.0579
Nickel (Ni)
1.78
ug/L
1
0.1004
Silver (Ag)
0.0521 U
ug/L
1
0.0521
DF
Method
Analysis Date/Time
Analyst
10
EPA 9056A
03/11/2026 09:55
BGN9034
1
EPA 9056A
03/11/2026 09:55
BGN9034
1
EPA 9056A
03/11/2026 09:55
BGN9034
1
EPA 9056A
03/11/2026 09:55
BGN9034
10
EPA 9056A
03/11/2026 09:55
BGN9034
1
EPA 7470A
03/16/2026 11:02
SNEGLIA
1
SW 601OD
03/24/2026 11:53
DDAUZVA
1
SW 601OD
03/20/2026 11:59
SNEGLIA
1
SW 601OD
03/20/2026 11:59
SNEGLIA
1
SW 601OD
03/20/2026 11:59
SNEGLIA
1
SW 601OD
03/20/2026 11:59
SNEGLIA
1
SW 601OD
03/20/2026 11:59
SNEGLIA
1
SW 601OD
03/20/2026 11:59
SNEGLIA
1
SW 601OD
03/20/2026 11:59
SNEGLIA
1
SW 601OD
03/20/2026 11:59
SNEGLIA
1
SW 601OD
03/20/2026 11:59
SNEGLIA
1
SW 6020B
03/17/2026 03:29
MHALL3
1
SW 6020E
03/17/2026 03:29
MHALL3
1
SW 6020B
03/17/2026 03:29
MHALL3
1
SW 6020E
03/17/2026 03:29
MHALL3
1
SW 6020E
03/17/2026 03:29
MHALL3
1
SW 6020E
03/17/2026 03:29
MHALL3
1
SW 6020B
03/17/2026 03:29
MHALL3
Certificate of Laboratory Analysis Page 5 of 19
This report shall not be reproduced, except in full.
Order # J26020414
Site: ALN SSLF-CD1 B
Collection Date: 03/10/2026 10:10 AM
Loc code: ALN SSLF-CD1 B
Sample #:
Matrix:
2026003774
GW RCRA
Analyte
Result
Units
Qualifiers RDL
MDL DF
Method
Analysis Date/Time
Analyst
TOTAL RECOVERABLE METALS BY ICP-MS -
Q26030265
Antimony (Sb)
0.1259 U
ug/L
1
0.1259
1 SW 6020B
03/18/2026 15:50
MHALL3
Arsenic (As)
0.168 U
ug/L
1
0.168
1 SW 6020E
03/18/2026 15:50
MHALL3
Beryllium (Be)
0.3106 U
ug/L
1
0.3106
1 SW 6020B
03/18/2026 15:50
MHALL3
Cadmium (Cd)
0.053 J
ug/L
1
0.0403
1 SW 6020E
03/18/2026 15:50
MHALL3
Chromium (Cr)
3.30
ug/L
1
0.2894
1 SW 6020E
03/18/2026 15:50
MHALL3
Cobalt (Co)
1.40
ug/L
1
0.1287
1 SW 6020E
03/18/2026 15:50
MHALL3
Copper (Cu)
0.924 J
ug/L
1
0.1994
1 SW 6020B
03/18/2026 15:50
MHALL3
Lead (Pb)
0.0579 U
ug/L
1
0.0579
1 SW 6020E
03/18/2026 15:50
MHALL3
Molybdenum (Mo)
0.1066 U
ug/L
1
0.1066
1 SW 6020B
03/18/2026 15:50
MHALL3
Nickel (Ni)
1.75
ug/L
1
0.1004
1 SW 6020E
03/18/2026 15:50
MHALL3
Selenium (Se)
0.737 J
ug/L
1
0.2052
1 SW 6020E
03/18/2026 15:50
MHALL3
Silver (Ag)
0.0521 U
ug/L
1
0.0521
1 SW 6020B
03/18/2026 15:50
MHALL3
Thallium (TI) Low Level
0.047 J
ug/L
0.2
0.0326
1 SW 6020E
03/18/2026 15:50
MHALL3
Vanadium (V)
0.668 J
ug/L
1
0.1119
1 SW 6020B
03/18/2026 15:50
MHALL3
TOTAL DISSOLVED SOLIDS -
Q26030233
TDS
233
mg/L
25
25
1 SM2540C
03/11/202614:47
LELL107
Certificate of Laboratory Analysis Page 6 of 19
This report shall not be reproduced, except in full.
Order # J26020414
Site: ALN SSLF-LCS1 Sample #: 2026003776
Collection Date: 03/10/2026 10:20 AM Loc code: ALN SSLF-LCS1 Matrix: GW RCRA
Analyte Result Units Qualifiers RDL MDL DF
INORGANIC IONS BY IC - 026030222
Chloride
16
mg/L
Fluoride
0.08 J
mg/L
Nitrate
1.2
mg/L
Nitrate as N
0.27
mg-N/L
Sulfate
680
mg/L
MERCURY (COLD VAPOR) IN WATER - Q26030343
Mercury (Hg)
0.01 J
ug/L
TOTAL RECOVERABLE METALS BY ICP -
Q26030258
Barium (Ba)
0.108
mg/L
Boron (B)
1.71
mg/L
Calcium (Ca)
287
mg/L
Iron (Fe)
1.16
mg/L
Lithium (Li)
0.016
mg/L B2
Magnesium (Mg)
42.5
mg/L
Manganese (Mn)
0.240
mg/L
Zinc (Zn)
0.007 J
mg/L
TOTAL RECOVERABLE METALS BY ICP-MS - Q26030265
Antimony (Sb)
0.961 J
ug/L
Arsenic (As)
3.16
ug/L
Beryllium (Be)
0.3106 U
ug/L
Cadmium (Cd)
0.108 J
ug/L
Chromium (Cr)
1.35 J
ug/L
Cobalt (Co)
0.977 J
ug/L
Copper (Cu)
8.09
ug/L
Lead (Pb)
1.11 J
ug/L
Molybdenum (Mo)
219
ug/L
Nickel (Ni)
4.07
ug/L
Selenium (Se)
736
ug/L
Silver (Ag)
0.0521 U
ug/L
Thallium (TI) Low Level
0.222 J
ug/L
Vanadium (V)
10.2
ug/L
TOTAL DISSOLVED SOLIDS -
Q26030233
TDS 1330 mg/L
Method Analysis Date/Time Analyst
0.5
0.015
5
EPA 9056A
03/11/2026 10:16
BGN9034
0.5
0.04
5
EPA 9056A
03/11/2026 10:16
BGN9034
0.5
0.04
5
EPA 9056A
03/11/2026 10:16
BGN9034
0.115
0.115
5
EPA 9056A
03/11/2026 10:16
BGN9034
10
0.041
100
EPA 9056A
03/11/2026 10:16
BGN9034
0.05
0.01
1
EPA 7470A
03/16/2026 11:10
SNEGLIA
0.005
0.0011
1
SW 601 OD
03/20/2026 09:26
SNEGLIA
0.05
0.0046
1
SW 601 OD
03/20/2026 09:26
SNEGLIA
0.5
0.0124
10
SW 601 OD
03/20/2026 09:26
SNEGLIA
0.01
0.0033
1
SW 601 OD
03/20/2026 09:26
SNEGLIA
0.005
0.0027
1
SW 601 OD
03/20/2026 09:26
SNEGLIA
0.02
0.0039
1
SW 601 OD
03/20/2026 09:26
SNEGLIA
0.005
0.0007
1
SW 601 OD
03/20/2026 09:26
SNEGLIA
0.015
0.0011
1
SW 601 OD
03/20/2026 09:26
SNEGLIA
2
0.1259
2
SW 6020B
03/18/2026 17:44
MHALL3
2
0.168
2
SW 6020E
03/18/2026 17:44
MHALL3
2
0.3106
2
SW 6020B
03/18/2026 17:44
MHALL3
2
0.0403
2
SW 6020B
03/18/2026 17:44
MHALL3
2
0.2894
2
SW 6020E
03/18/2026 17:44
MHALL3
2
0.1287
2
SW 6020E
03/18/2026 17:44
MHALL3
2
0.1994
2
SW 6020B
03/18/2026 17:44
MHALL3
2
0.0579
2
SW 6020E
03/18/2026 17:44
MHALL3
2
0.1066
2
SW 6020E
03/18/2026 17:44
MHALL3
2
0.1004
2
SW 6020B
03/18/2026 17:44
MHALL3
2
0.2052
2
SW 6020E
03/18/2026 17:44
MHALL3
2
0.0521
2
SW 6020B
03/18/2026 17:44
MHALL3
0.4
0.0326
2
SW 6020E
03/18/2026 17:44
MHALL3
2
0.1119
2
SW 6020B
03/18/2026 17:44
MHALL3
25
25
1
SM2540C
03/11/202614:47
LELL107
Certificate of Laboratory Analysis Page 7 of 19
This report shall not be reproduced, except in full.
Order # J26020414
Site: ALN FB-20260310-1000 Field Blank Sample #: 2026003777
Collection Date: 03/10/2026 10:00 AM Loc code: ALN QA Matrix: GW RCRA
Analyte Result Units Qualifiers RDL MDL DF
INORGANIC IONS BY IC - 026030222
Chloride
0.015 U
mg/L
Fluoride
0.04 U
mg/L
Nitrate
0.04 U
mg/L
Nitrate as N
0.023 U
mg-N/L
Sulfate
0.041 U
mg/L
MERCURY (COLD VAPOR) IN WATER - Q26030343
Mercury (Hg)
0.01 U
ug/L
TOTAL RECOVERABLE METALS BY ICP -
Q26030258
Barium (Ba)
0.0011 U
mg/L
Boron (B)
0.03 J
mg/L
Calcium (Ca)
0.0124 U
mg/L
Iron (Fe)
0.0033 U
mg/L
Lithium (Li)
0.005
mg/L B2
Magnesium (Mg)
0.0039 U
mg/L
Manganese (Mn)
0.0007 U
mg/L
Zinc (Zn)
0.0011 U
mg/L
TOTAL RECOVERABLE METALS BY ICP-MS - Q26030265
Antimony (Sb)
0.1259 U
ug/L
Arsenic (As)
0.168 U
ug/L
Beryllium (Be)
0.3106 U
ug/L
Cadmium (Cd)
0.0403 U
ug/L
Chromium (Cr)
0.2894 U
ug/L
Cobalt (Co)
0.1287 U
ug/L
Copper (Cu)
0.1994 U
ug/L
Lead (Pb)
0.0579 U
ug/L
Molybdenum (Mo)
0.1066 U
ug/L
Nickel (Ni)
0.1004 U
ug/L
Selenium (Se)
0.2052 U
ug/L
Silver (Ag)
0.0521 U
ug/L
Thallium (TI) Low Level
0.0326 U
ug/L
Vanadium (V)
0.1119 U
ug/L
Method Analysis Date/Time Analyst
0.1
0.015
1
EPA 9056A
03/11/2026 07:52
BGN9034
0.1
0.04
1
EPA 9056A
03/11/2026 07:52
BGN9034
0.1
0.04
1
EPA 9056A
03/11/2026 07:52
BGN9034
0.023
0.023
1
EPA 9056A
03/11/2026 07:52
BGN9034
0.1
0.041
1
EPA 9056A
03/11/2026 07:52
BGN9034
0.05
0.01
1
EPA 7470A
03/16/2026 11:18
SNEGLIA
0.005
0.0011
1
SW 601OD
03/20/2026 11:59
SNEGLIA
0.05
0.0046
1
SW 601OD
03/20/2026 11:59
SNEGLIA
0.05
0.0124
1
SW 601OD
03/20/2026 11:59
SNEGLIA
0.01
0.0033
1
SW 601OD
03/20/2026 11:59
SNEGLIA
0.005
0.0027
1
SW 601OD
03/20/2026 11:59
SNEGLIA
0.02
0.0039
1
SW 601OD
03/20/2026 11:59
SNEGLIA
0.005
0.0007
1
SW 601OD
03/20/2026 11:59
SNEGLIA
0.015
0.0011
1
SW 601OD
03/20/2026 11:59
SNEGLIA
1
0.1259
1
SW 6020B
03/18/2026 15:59
MHALL3
1
0.168
1
SW 6020E
03/18/2026 15:59
MHALL3
1
0.3106
1
SW 6020B
03/18/2026 15:59
MHALL3
1
0.0403
1
SW 6020B
03/18/2026 15:59
MHALL3
1
0.2894
1
SW 6020E
03/18/2026 15:59
MHALL3
1
0.1287
1
SW 6020E
03/18/2026 15:59
MHALL3
1
0.1994
1
SW 6020B
03/18/2026 15:59
MHALL3
1
0.0579
1
SW 6020E
03/18/2026 15:59
MHALL3
1
0.1066
1
SW 6020E
03/18/2026 15:59
MHALL3
1
0.1004
1
SW 6020B
03/18/2026 15:59
MHALL3
1
0.2052
1
SW 6020E
03/18/2026 15:59
MHALL3
1
0.0521
1
SW 6020B
03/18/2026 15:59
MHALL3
0.2
0.0326
1
SW 6020E
03/18/2026 15:59
MHALL3
1
0.1119
1
SW 6020B
03/18/2026 15:59
MHALL3
Certificate of Laboratory Analysis Page 8 of 19
This report shall not be reproduced, except in full.
Order # J26020414
Qualifiers:
B2 Target analyte was detected in Method/Prep Blank(s) at a concentration greater than '/2 the reporting limit but less than the
reporting limit. Analyte concentration in sample is valid and may be used for compliance purposes.
J Analyte detected above the MDL, but below the RL. Analyte concentration should be considered an estimate.
Certificate of Laboratory Analysis Page 9 of 19
This report shall not be reproduced, except in full.
Order # J26020414
Level II QC Summary
Q26030222 Dionex INORGANIC IONS BY IC
Blank # 1
Parameter
Measured
Final
Units
Dil
MDL
RDL
Relative Concentration
Qualifier
Chloride
0
0
mg/L
1
0.015
0.1
< MDL
Fluoride
0
0
mg/L
1
0.04
0.1
< MDL
Nitrate
0
0
mg/L
1
0.04
0.1
< MDL
Sulfate
0
0
mg/L
1
0.041
0.1
< MDL
LCS # 1
Parameter
Measured
Final
Units
Dil
MDL
Spike
% Recovery
LCL
UCL
Qualifier
Chloride
5.1
5.1
mg/L
1
0.015
5
102
80
120
Fluoride
4.83
4.83
mg/L
1
0.04
5
96.7
80
120
Nitrate
5.24
5.24
mg/L
1
0.04
5
105
80
120
Sulfate
5.2
5.2
mg/L
1
0.041
5
104
80
120
MS # 1
Parent Sample:
J26020411
-- 2026003765
Parameter
Measured
Final
Units
Dil
MDL
Spike
% Recovery
LCL
UCL
Qualifier
Chloride
7.72
7.72
mg/L
1
0.015
5
101
80
120
Fluoride
4.95
4.95
mg/L
1
0.04
5
97.6
80
120
Nitrate
6.76
6.76
mg/L
1
0.04
5
103
80
120
Sulfate
7.88
7.88
mg/L
1
0.041
5
99.2
80
120
MSD # 1
Parent Sample:
J26020411
-- 2026003765
Parameter
Measured
Final
Units
Dil
MDL
Spike
% Recovery
LCL
UCL
RPD
Qualifier
Chloride
7.69
7.69
mg/L
1
0.015
5
100
80
120
0.493
Fluoride
4.92
4.92
mg/L
1
0.04
5
96.9
80
120
0.649
Nitrate
6.71
6.71
mg/L
1
0.04
5
102
80
120
0.743
Sulfate
7.86
7.86
mg/L
1
0.041
5
98.8
80
120
0.254
Certificate of Laboratory Analysis Page 10 of 19
This report shall not be reproduced, except in full.
Order # J26020414
Level II QC Summary
Q26030343 HG 7470 MERCURY (COLD VAPOR) IN WATER
Blank # 1
Parameter
Measured
Final
Units
Dil
MDL
RDL
Relative Concentration
Qualifier
Mercury (Hg)
-0.002
-0.002
ug/L
1
0.01
0.05
< MDL
Blank # 2
Parameter
Measured
Final
Units
Dil
MDL
RDL
Relative Concentration
Qualifier
Mercury (Hg)
-0.02
-0.02
ug/L
1
0.01
0.05
< MDL
Blank # 3
Parameter
Measured
Final
Units
Dil
MDL
RDL
Relative Concentration
Qualifier
Mercury (Hg)
-0.025
-0.025
ug/L
1
0.01
0.05
< MDL
Blank # 4
Parameter
Measured
Final
Units
Dil
MDL
RDL
Relative Concentration
Qualifier
Mercury (Hg)
-0.009
-0.009
ug/L
1
0.01
0.05
< MDL
LCS # 1
Parameter
Measured
Final
Units
Dil
MDL
Spike
% Recovery LCL
UCL
Qualifier
Mercury (Hg)
2.04
2.04
ug/L
1
0.01
2
102 85
115
LCS # 2
Parameter
Measured
Final
Units
Dil
MDL
Spike
% Recovery LCL
UCL
Qualifier
Mercury (Hg)
2.04
2.04
ug/L
1
0.01
2
102 85
115
LCS # 3
Parameter
Measured
Final
Units
Dil
MDL
Spike
% Recovery
LCL UCL
Qualifier
Mercury (Hg)
2.03
2.03
ug/L
1
0.01
2
102
85 115
MS # I
Parent Sample:
J26020411 -- 2026003765
Parameter
Measured
Final
Units
Dil
MDL
Spike
% Recovery
LCL UCL
Qualifier
Mercury (Hg)
1.12
1.12
ug/L
1
0.01
1
112
75 125
MSD # I
Parent Sample:
J26020411 -- 2026003765
Parameter
Measured
Final
Units
Dil
MDL
Spike
% Recovery
LCL UCL RPD
Qualifier
Mercury (Hg)
1.1
1.1
ug/L
1
0.01
1
110
75 125 1.26
MS # 2
Parent Sample:
J26020414 -- 2026003776
Parameter
Measured
Final
Units
Dil
MDL
Spike
% Recovery
LCL UCL
Qualifier
Mercury (Hg)
1.1
1.1
ug/L
1
0.01
1
109
75 125
MSD # 2
Parent Sample:
J26020414 -- 2026003776
Parameter
Measured
Final
Units
Dil
MDL
Spike
% Recovery
LCL UCL RPD
Qualifier
Mercury (Hg)
1.08
1.08
ug/L
1
0.01
1
107
75 125 1.86
Certificate of Laboratory Analysis Page 11 of 19
This report shall not be reproduced, except in full.
Order # J26020414
Level II QC Summary
Q26030343 HG 7470 MERCURY (COLD VAPOR) IN WATER
lU G`E°#;
MSD # 3
MS # 4
MSD # 4
Parameter Measured Final
Mercury (Hg) 1.03 1.03
Parameter Measured Final
Mercury (Hg) 1.04 1.04
Parameter Measured Final
Mercury (Hg) 0.994 0.994
Parameter Measured Final
Mercury (Hg) 1 1
Parent Sample:
J26030216 -- 2026005323
Units
Dil
MDL
Spike
% Recovery
LCL UCL
ug/L
1
0.01
1
103
75 125
Parent Sample:
J26030216 -- 2026005323
Units
Dil
MDL
Spike
% Recovery
LCL UCL RPD
ug/L
1
0.01
1
104
75 125 1.26
Parent Sample:
J26030216 -- 2026005333
Units
Dil
MDL
Spike
% Recovery
LCL UCL
ug/L
1
0.01
1
99.3
75 125
Parent Sample:
J26030216 -- 2026005333
Units
Dil
MDL
Spike
% Recovery
LCL UCL RPD
ug/L
1
0.01
1
99.9
75 125 0.602
Qualifier
Qualifier
Qualifier
Qualifier
Certificate of Laboratory Analysis Page 12 of 19
This report shall not be reproduced, except in full.
Order # J26020414
Level II QC Summary
Q26030254 ICP_DIS_TRM TOTAL RECOVERABLE METALS BY ICP (DISSOLVED)
Blank # 1
LCS # 1
Parameter Measured Final
Zinc (Zn) 0.000154 0.000154
Parameter Measured Final
Zinc (Zn) 4.55 4.55
LCSD # 1
Parameter Measured Final
Zinc (Zn) 4.65 4.65
Units Dil MDL RDL Relative Concentration
mg/L 1 0.0011 0.015 < MDL
Units Dil MDL Spike % Recovery LCL UCL
mg/L 1 0.0011 5 91.1 80 120
Units Dil MDL Spike % Recovery LCL UCL
mg/L 1 0.0011 5 92.9 80 120
Qualifier
Qualifier
RPD Qualifier
2
Certificate of Laboratory Analysis Page 13 of 19
This report shall not be reproduced, except in full.
Order # J26020414
Level II QC Summary
Q26030258 ICP_TRM TOTAL RECOVERABLE METALS BY ICP
Blank # 1
Parameter
Measured
Final
Units
Dil
MDL
RDL
Relative Concentration
Barium (Ba)
-0.000247
-0.000247
mg/L
1
0.0011
0.005
< MDL
Boron (B)
0.00145
0.00145
mg/L
1
0.0046
0.05
< MDL
Calcium (Ca)
0.000725
0.000725
mg/L
1
0.0124
0.05
< MDL
Iron (Fe)
0.00224
0.00224
mg/L
1
0.0033
0.01
< MDL
Lithium (Li)
0.00436
0.00436
mg/L
1
0.0027
0.005
> MDL
Magnesium (Mg)
0.000031
0.000031
mg/L
1
0.0039
0.02
< MDL
Manganese (Mn)
0.000258
0.000258
mg/L
1
0.0007
0.005
< MDL
Zinc (Zn)
0.00184
0.00184
mg/L
1
0.0011
0.015
> MDL
LCS # 1
Parameter
Measured
Final
Units
Dil
MDL
Spike
% Recovery
LCL
UCL
Barium (Ba)
5.16
5.16
mg/L
1
0.0011
5
103
80
120
Boron (B)
5.09
5.09
mg/L
1
0.0046
5
102
80
120
Calcium (Ca)
5.06
5.06
mg/L
1
0.0124
5
101
80
120
Iron (Fe)
5.13
5.13
mg/L
1
0.0033
5
103
80
120
Lithium (Li)
5.13
5.13
mg/L
1
0.0027
5
103
80
120
Magnesium (Mg)
5.12
5.12
mg/L
1
0.0039
5
102
80
120
Manganese (Mn)
5.11
5.11
mg/L
1
0.0007
5
102
80
120
Zinc (Zn)
5.1
5.1
mg/L
1
0.0011
5
102
80
120
MS # 1
Parent Sample:
J26020411
-- 2026003765
Parameter
Measured
Final
Units
Dil
MDL
Spike
% Recovery
LCL
UCL
Barium (Ba)
5.28
5.28
mg/L
1
0.0011
5
105
75
125
Boron (B)
5.19
5.19
mg/L
1
0.0046
5
104
75
125
Calcium (Ca)
13.8
13.8
mg/L
1
0.0124
5
99.8
75
125
Iron (Fe)
5.27
5.27
mg/L
1
0.0033
5
105
75
125
Lithium (Li)
5.19
5.19
mg/L
1
0.0027
5
104
75
125
Magnesium (Mg)
7.18
7.18
mg/L
1
0.0039
5
102
75
125
Manganese (Mn)
5.22
5.22
mg/L
1
0.0007
5
104
75
125
Zinc (Zn)
5.18
5.18
mg/L
1
0.0011
5
103
75
125
MSD # 1
Parent Sample:
J26020411
-- 2026003765
Parameter
Measured
Final
Units
Dil
MDL
Spike
% Recovery
LCL
UCL
RPD
Barium (Ba)
5.24
5.24
mg/L
1
0.0011
5
104
75
125
0.76
Boron (B)
5.21
5.21
mg/L
1
0.0046
5
104
75
125
0.385
Calcium (Ca)
14
14
mg/L
1
0.0124
5
104
75
125
1.44
Iron (Fe)
5.23
5.23
mg/L
1
0.0033
5
105
75
125
0.762
Lithium (Li)
5.18
5.18
mg/L
1
0.0027
5
104
75
125
0.193
Magnesium (Mg)
7.19
7.19
mg/L
1
0.0039
5
102
75
125
0.139
Manganese (Mn)
5.18
5.18
mg/L
1
0.0007
5
103
75
125
0.769
Qualifier
B2
Qualifier
Qualifier
Qualifier
Certificate of Laboratory Analysis Page 14 of 19
This report shall not be reproduced, except in full.
Order # J26020414
Level II QC Summary
Q26030258 ICP_TRM TOTAL RECOVERABLE METALS BY ICP
MSD # 1 Parent Sample: J26020411 -- 2026003765
Parameter Measured Final Units Dil MDL Spike % Recovery LCL UCL RPD Qualifier
Zinc (Zn) 5.16 5.16 mg/L 1 0.0011 5 103 75 125 0.387
Qualifiers:
B2 Target analyte was detected in Method/Prep Blank(s) at a concentration greater than '/2 the reporting limit but
less than the reporting limit. Analyte concentration in sample is valid and may be used for compliance
purposes.
Certificate of Laboratory Analysis Page 15 of 19
This report shall not be reproduced, except in full.
Order # J26020414
Level II QC Summary
Q26030262 IMS_DIS_TRM TOTAL RECOVERABLE METALS BY ICP-MS (DISSOLVED)
Blank # 1
LCS # 1
Parameter
Measured
Final
Units
Dil
MDL
RDL
Relative Concentration
Qualifier
Beryllium (Be)
0.004
0.004
ug/L
1
0.3106
1
< MDL
Cadmium (Cd)
0.004
0.004
ug/L
1
0.0403
1
< MDL
Chromium (Cr)
0.023
0.023
ug/L
1
0.2894
1
< MDL
Copper (Cu)
-0.031
-0.031
ug/L
1
0.1994
1
< MDL
Lead (Pb)
0
0
ug/L
1
0.0579
1
< MDL
Nickel (Ni)
0.009
0.009
ug/L
1
0.1004
1
< MDL
Silver (Ag)
0.001
0.001
ug/L
1
0.0521
1
< MDL
Parameter
Measured
Final
Units
Dil
MDL
Spike
% Recovery
LCL
UCL Qualifier
Beryllium (Be)
47.8
47.8
ug/L
1
0.3106
50
95.7
80
120
Cadmium (Cd)
49.2
49.2
ug/L
1
0.0403
50
98.3
80
120
Chromium (Cr)
49.6
49.6
ug/L
1
0.2894
50
99.3
80
120
Copper (Cu)
50.6
50.6
ug/L
1
0.1994
50
101
80
120
Lead (Pb)
52.2
52.2
ug/L
1
0.0579
50
104
80
120
Nickel (Ni)
50.3
50.3
ug/L
1
0.1004
50
101
80
120
Silver (Ag)
53.8
53.8
ug/L
1
0.0521
50
108
80
120
LCSD # 1
Parameter
Measured
Final
Units
Dil
MDL
Spike
% Recovery
LCL
UCL
RPD Qualifier
Beryllium (Be)
49.7
49.7
ug/L
1
0.3106
50
99.4
80
120
3.81
Cadmium (Cd)
50.7
50.7
ug/L
1
0.0403
50
101
80
120
3.18
Chromium (Cr)
51
51
ug/L
1
0.2894
50
102
80
120
2.68
Copper (Cu)
53.1
53.1
ug/L
1
0.1994
50
106
80
120
4.72
Lead (Pb)
53.8
53.8
ug/L
1
0.0579
50
108
80
120
3.13
Nickel (Ni)
52.3
52.3
ug/L
1
0.1004
50
105
80
120
4
Silver(Ag)
55.7
55.7
ug/L
1
0.0521
50
111
80
120
3.64
Certificate of Laboratory Analysis Page 16 of 19
This report shall not be reproduced, except in full.
Order # J26020414
Level II QC Summary
Q26030265 IMS_TRM TOTAL RECOVERABLE METALS BY ICP-MS
Blank # 1
Parameter
Measured
Final
Units
Dil
MDL
RDL
Relative Concentration
Antimony (Sb)
-0.064
-0.064
ug/L
1
0.1259
1
< MDL
Arsenic (As)
0.017
0.017
ug/L
1
0.168
1
< MDL
Beryllium (Be)
0.016
0.016
ug/L
1
0.3106
1
< MDL
Cadmium (Cd)
-0.001
-0.001
ug/L
1
0.0403
1
< MDL
Chromium (Cr)
0.017
0.017
ug/L
1
0.2894
1
< MDL
Cobalt (Co)
-0.004
-0.004
ug/L
1
0.1287
1
< MDL
Copper (Cu)
0.022
0.022
ug/L
1
0.1994
1
< MDL
Lead (Pb)
-0.004
-0.004
ug/L
1
0.0579
1
< MDL
Molybdenum (Mo)
0.021
0.021
ug/L
1
0.1066
1
< MDL
Nickel (Ni)
-0.008
-0.008
ug/L
1
0.1004
1
< MDL
Selenium (Se)
0
0
ug/L
1
0.2052
1
< MDL
Silver (Ag)
0.002
0.002
ug/L
1
0.0521
1
< MDL
Thallium (TI) Low Level
0.017
0.017
ug/L
1
0.0326
0.2
< MDL
Vanadium (V)
-0.008
-0.008
ug/L
1
0.1119
1
< MDL
LCS # 1
Parameter
Measured
Final
Units
Dil
MDL
Spike
% Recovery
LCL
UCL
Antimony (Sb)
56.5
56.5
ug/L
1
0.1259
50
113
80
120
Arsenic (As)
52.8
52.8
ug/L
1
0.168
50
106
80
120
Beryllium (Be)
53.1
53.1
ug/L
1
0.3106
50
106
80
120
Cadmium (Cd)
55
55
ug/L
1
0.0403
50
110
80
120
Chromium (Cr)
53.2
53.2
ug/L
1
0.2894
50
106
80
120
Cobalt (Co)
54.1
54.1
ug/L
1
0.1287
50
108
80
120
Copper (Cu)
54.4
54.4
ug/L
1
0.1994
50
109
80
120
Lead (Pb)
55.5
55.5
ug/L
1
0.0579
50
111
80
120
Molybdenum (Mo)
55
55
ug/L
1
0.1066
50
110
80
120
Nickel (Ni)
54.1
54.1
ug/L
1
0.1004
50
108
80
120
Selenium (Se)
53
53
ug/L
1
0.2052
50
106
80
120
Silver(Ag)
54.5
54.5
ug/L
1
0.0521
50
109
80
120
Thallium (TI) Low Level
51.1
51.1
ug/L
1
0.0326
50
102
80
120
Vanadium (V)
54.3
54.3
ug/L
1
0.1119
50
109
80
120
MS # 1
Parent Sample:
J26020411
-- 2026003766
Parameter
Measured
Final
Units
Dil
MDL
Spike
% Recovery
LCL
UCL
Antimony (Sb)
27.5
55
ug/L
2
0.1259
50
109
75
125
Arsenic (As)
27.1
54.2
ug/L
2
0.168
50
105
75
125
Beryllium (Be)
24.8
49.6
ug/L
2
0.3106
50
99.1
75
125
Cadmium (Cd)
26
52
ug/L
2
0.0403
50
104
75
125
Chromium (Cr)
25.9
51.8
ug/L
2
0.2894
50
103
75
125
Cobalt (Co)
40
80.1
ug/L
2
0.1287
50
100
75
125
Qualifier
Qualifier
Qualifier
Certificate of Laboratory Analysis
This report shall not be reproduced, except in full.
Order # J26020414
Level II QC Summary
Q26030265 IMS_TRM TOTAL RECOVERABLE METALS BY ICP-MS
MS # 1
Parameter
Measured
Final
Units
Dil
MDL
Spike
Copper (Cu)
26.7
53.5
ug/L
2
0.1994
50
Lead (Pb)
26.9
53.8
ug/L
2
0.0579
50
Molybdenum (Mo)
170
341
ug/L
2
0.1066
50
Nickel (Ni)
37
74
ug/L
2
0.1004
50
Selenium (Se)
168
336
ug/L
2
0.2052
50
Silver (Ag)
25
50
ug/L
2
0.0521
50
Thallium (TI) Low Level
22.9
45.9
ug/L
2
0.0326
50
Vanadium (V)
27.5
55
ug/L
2
0.1119
50
MSD # 1
Parameter
Measured
Final
Units
Dil
MDL
Spike
Antimony (Sb)
27.8
55.7
ug/L
2
0.1259
50
Arsenic (As)
27.5
55
ug/L
2
0.168
50
Beryllium (Be)
25.2
50.5
ug/L
2
0.3106
50
Cadmium (Cd)
26.4
52.8
ug/L
2
0.0403
50
Chromium (Cr)
26.2
52.5
ug/L
2
0.2894
50
Cobalt (Co)
40.9
81.8
ug/L
2
0.1287
50
Copper (Cu)
27.3
54.7
ug/L
2
0.1994
50
Lead (Pb)
27.2
54.4
ug/L
2
0.0579
50
Molybdenum (Mo)
171
343
ug/L
2
0.1066
50
Nickel (Ni)
38
76
ug/L
2
0.1004
50
Selenium (Se)
169
337
ug/L
2
0.2052
50
Silver (Ag)
25.6
51.3
ug/L
2
0.0521
50
Thallium (TI) Low Level
23.4
46.8
ug/L
2
0.0326
50
Vanadium (V)
28
56.1
ug/L
2
0.1119
50
Page 17 of 19
Parent Sample: J26020411 -- 2026003766
% Recovery
LCL
UCL
99.7
75
125
108
75
125
107
75
125
101
75
125
113
75
125
100
75
125
89.9
75
125
107
75
125
Parent Sample: J26020411 -- 2026003766
% Recovery
LCL
UCL
RPD
111
75
125
1.19
107
75
125
1.45
101
75
125
1.78
105
75
125
1.61
104
75
125
1.39
103
75
125
2.07
102
75
125
2.2
109
75
125
1.14
110
75
125
0.495
104
75
125
2.65
115
75
125
0.377
103
75
125
2.47
91.8
75
125
2.05
110
75
125
1.87
Qualifier
Qualifier
Certificate of Laboratory Analysis Page 18 of 19
This report shall not be reproduced, except in full.
Order # J26020414
Level II QC Summary
Q26030233 TDS TOTAL DISSOLVED SOLIDS
Blank # 1
Blank # 2
Parameter Measured Final
TDS 0
Parameter Measured Final
TDS 0
Duplicate # 1
Parameter Measured Final
TDS 806
Duplicate # 2
Parameter Measured Final
TDS 351
LCS # 1
LCS # 2
Parameter Measured Final
TDS 491
Parameter Measured Final
TDS 489
Units
Dil
MDL
RDL
Relative Concentration
Qualifier
mg/L
1
25
25
< MDL
Units
Dil
MDL
RDL
Relative Concentration
Qualifier
mg/L
1
25
25
< MDL
Parent Sample:
J26020003 -- 2026002211
Units
Dil
MDL
RPD
Qualifier
mg/L
1
25
1.36
Parent Sample:
J26030319 -- 2026005863
Units
Dil
MDL
RPD
Qualifier
mg/L
1
25
0.285
Units
Dil
MDL
Spike
% Recovery
LCL
UCL
Qualifier
mg/L
1
25
500
98.2
90
110
Units
Dil
MDL
Spike
% Recovery
LCL
UCL
Qualifier
mg/L
1
25
500
97.8
90
110
('DUKE Duke Energy Analytical Laboratory I 1
Mmlcod MG03nz Ferry Rd (Bmltlfng7as) i
13
339 Hag:r iOrdar#~ J26020414
ENERGY Rumen-11., N.t. 29378 + iLogs.dB
II y
pal ns-sus
_ _ _ _ _ _ _ _ _ _ _ co
EZ.IZ 4ansaogs ._._._._._.�
Project Name ALLEN SOUTH STARTER LANDFILL Phone No: !Vendor
$ PERMIT 3020-INDUS
Client COURTNEY MURPHY, BRYAN MOELLER. DEE TO
O'BRIEN, JOSH STOWE, CONNOR ZAHORA
f !
Operating Unit: AS00 Process:NGRDWTR Account: i
L.._.._--_.._.. -------
Project: AAS000415 Activity ID: Facility ID"
G Program / EOuiS Task Code: ALW Sub-ProgramlTask Code:
Sample Description or ID
ALN_SSLF-CD1B
ALN=66EfSZLL Ch
ALN_SSLF-LCS1
ALN_FB- Zu4 o3t0- 1000
CHAIN OF CUSTODY RECORD AND ANALYSIS REQUEST FORM
-------------------------------------------ao.i - ical L-aeo:aio --use o�i--------------------------- ------------------------------------------ Page 19 of 19
Matrix WATER _ Page t_of_1_
s.mP�.. o,�.,�.o�, r,.m NC_Xsc_ DISTRIBUTION
SAMPLE PROGRAM ORIGINAL to LAB, COPY to CLIENT
Ground Water X_ NPDES_
Drinking Water_ UST_
1I RCRA Waste
_.._.._.._ _.._.. Cooler _�mp10�.._..__.._.-_.._.._--_--_.._.._._.._--_----._.._.._.._.._-.-.._.._.._.._--_.._--_
'• Filtration (0.45 um) b Unfiltered b Filtered
i Preservative ICE I ICE
Container Volume (mL) 500 300 500 260
ContalnerType HDPE PET PET HDPE
Customer to complete all appropriate non -shaded areas.
3-10-U (wo .&wArp2zAl"Ol,+
3 -0- Zd 10 zU Co *cm 24Pv"
3-to-iL 1000 Cewwa ?At4ou
'
(Metals Prep - TRIM) /
Cl, F,
12
(ICP - SW 6010D) Ba, B,
NO3-N
y rc o
Ca, Fe, Li, Mg, Mn, Zn
(8) / Hg (SW 7470A) I
(48-Hr
Hold
MS
SW6010D Zn / SW
6
m
c
(IMS - SW 6020B) Sb,
Time),
Cu, Pb,Ni,Cr,
Cu, b, i, Ag
V
Tn
As, Be, Cd, Cr, Co, Cu,
Pb, Mo, Ni, Se, Ag,
SO4F
_
TI LL V 14
X
1
i
1
1
4
X
-t
4.
t
t
X
1
1
1
3
X
1
1
2
By
ri((%-
me
Date/Time
Atu�74�- uaei ime
,1Gw U`ai%�aCG�/
m
u
v
a v
� c
o.
c
Requested TurnaroundRellnquishatl
21 Days
14 Days X
Relinquished By Date/Time
Accepted Dat&M
Relinquished By Data/Time
Accepted By: Datenime
;
Q, wDays
E m
— N
r �
m
-7
Seal/Locked By DatelTime
Sealed/Lock Opened By Date/Thins,
Comments
EQUIS EDD Required
o
0
'Other
[For ALN_SSLF-CD1B and
ALN_SSLF-SW7, include Total Hardness in ICP_TRM metals list]
U
-Add Cost Will Apply