Loading...
HomeMy WebLinkAbout7607_GreatOakMSWLF_Comment_partialCell1ACQARpt_DIN26837_201610111 Chao, Ming-tai From:Chao, Ming-tai Sent:Tuesday, October 11, 2016 4:19 PM To:'Lamb, Steve' Cc:Murray, John E Subject:Comments on the Great Oak Landfill - Partial CQA Report, DIN 26837 Attachments:Microsoft Outlook - Memo Style.pdf Hi Steve: I hope Hurricane Matthew did not create any problem or delay the landfill construction project; if any or need any assistance from our end please inform us. I got lucky and didn’t face any problem or have any property damage from this hurricane, and hope you and your family all safe and sound and dodge the storm as well. John and his wife had evacuated from the coastal area so he is not reachable at this moment. I completed a review of the draft (Partial) CQA Report (DIN 26813) for the above mentioned landfill construction and have some comments on the report or require additional data. The comments are stated below: General 1. Please include the following documents related to this landfill construction project to the CQA Report: i. Pre-construction and progressive meeting minutes. ii. Memo for resolving the testing frequency for geosynthetic material and any other item deviates from the approved cell design, Technical Specifications, or CQA Plan but is approved by the Engineer, for example the portion of the Cell 1 area/subgrade are field modified due to the power line right-of-way (guy-wire anchor) owned by Duke Energy. iii. Leach tank foundation reports adds to the Appendix F iv. Leak location testing work plan adds to the Appendix H. 2. (Cover page) The Facility Permit Number is 7607-MSWLF-2015, please correct the typo. Section 3 & Appendix A-1 3. The PI of the soil sample SF-6 stated in Table 1 is different from that in Appendix A-1. Please clarify. 4. Soil Sample 21814-SF-1 is classified as CH based on the USCS which does not meet the fill material specification – Section 31 2323.13 (Part 2.01A). The CQA Report, Section 3 & Table 1 should state if the borrow area/location which this soil sample is representing for was used as Type S1 - structural fill in this project. Section 3 & Appendix A-2 5. The calculated % of compaction for the sample SF-22 is likely incorrect. Please verify and make necessary correction. 6. For test sample SF-77 the maximum dry density of 99.7 pcf for the referenced sample SF-9 is likely incorrect. This error carries over so the calculated % of compaction for the sample SF-77 is likely incorrect. Please verify and make necessary correction. 2 7. Moisture content of the test sample SF-35 is outside the specified range of 3%. If this exceedance is acceptable, the Engineer must approve this deviation which should be documented to the Section 3 of the CQA Report. 8. The in-situ moisture content for each test sample must be conducted by ASTM D 2216 according to fill material specification – Section 31 2323.13 (Part 3.05B.2). Please provide the laboratory data of the moisture content test. If other in-situ testing methods are used, the Engineer must approve this deviation which should be documented to the Section 3 of the CQA Report. Appendix B 9. In the Report of Subgrade Inspection and vertical Separation Certification dated September 9, 2016, the four (4)-feet separation/vertical buffer is likely not achieving at the following location points – PT2030, PT2032, and PT2043. Please verify the measurements. (Christin Ritter has sent this comment to Mike Cobb via an e-mail dated 10/06/2016 - attached) Appendix C-1 10. The summary sheet for Agru 60HD Microspike Roll 16 through 30 has the Lot#HGF820370 but the Quality Certificate Sheets have the Lot# HGF821370. Please explain this discrepancy. 11. The certification letters dated June 17,2015 from Chevron Philips shows testing results of HP-OIT, Oven Aging & UV Aging on the HDPE samples which are from the geomembrane not being used for this landfill project. The Lot# and Roll # of geomembrane from which the samples were collected/cut do not match any identification on the material delivery sheets. Please explain why the testing results from samples coming a batch of geomembrane which is not used for this project are acceptable. 12. The TRI certification letters dated April 19, 2010 shows testing results of Oven Aging & UV Aging on the “SMOOTH” HDPE samples. The construction drawings and technical specifications require textured geomembrane for this landfill project. Please clarify. Appendix C-2 13. TRI testing result report dated August 16, 2016 contains CQA Conformance Testing Samples from HDPE Roll Nos. G16D003037, G16D003048 & G16D003056 which can’t be identified in the delivery sheet. 14. CQA Conformance Testing Samples from HDPE Roll Nos. G16B003048 (Roll 49) & G16B003056 (Roll 57) are not included in the CQA Report. Section 5.2 & Appendix D-2 15. Section 5.2 stated that geonet should be tested for tensile properties (by ASTM D 5035) and geotextile should be tested for UV Resistance (by ASTM D 4355) & AOS (by ASTM D 4751), but those test results can’t be found in Appendix D-2. Please provide test results. Section 6 & Appendix E-1 16. Section 6.0 stated that 116 rolls of GCL were purchased for the project site, but the GCL Packing List and MQA Tracking Forms document 276 rolls (180 rolls from Oder No. 55006362 & 96 rolls from Oder No. 55006854) have been delivered to the project site. Please clarify. 3 17. MQA Full Geotextile Cert 01-9514 does include the test results for the (Cover Geotextile) roll # 2024581479 (Oder No. 55006362). Please provide the data. Please contact me if you have any questions about the comments. Have a wonderful day. By the way, please inform us (give us a few day heads-up) the date and time to start the leak location test at Cell 1A area. Ming Chao Ming-Tai Chao, P.E. Environmental Engineer Permitting Branch, Solid Waste Section NCDEQ, Division of Waste Management (Mailing Address) 1646 Mail Service Center Raleigh, NC 27699-1646 (Street Address) Green Square, 217 West Jones Street Raleigh, NC 27603 Tel. 919-707-8251 ming.chao@ncdenr.gov http://portal.ncdenr.org/web/wm/sw E-mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties. From: Lamb, Steve [mailto:SLamb@scsengineers.com] Sent: Tuesday, October 04, 2016 4:07 PM To: Chao, Ming-tai <ming.chao@ncdenr.gov> Subject: RE: Great Oak Landfill - Partial CQA Report Ming: And here it is. Partial Construction Documentation Report, Great Oak Landfill. If it would help to facilitate your review, I am able to come up to Raleigh and meet with you. Thanks for helping us and Waste Management of the Carolinas out by agreeing to review this partial report. We appreciate it. The hard copy is being sent out tonight. Thanks, Steve Lamb, PE Vice President SCS Engineers 4 2520 Whitehall Park Drive, Suite 450 Charlotte, North Carolina 28273 Office – 704.504.3107 Direct - 704-916-1529 Mobile – 704.576.4731 From: Chao, Ming-tai [mailto:ming.chao@ncdenr.gov] Sent: Tuesday, October 04, 2016 1:04 PM To: Lamb, Steve Subject: RE: Great Oak Landfill - Partial CQA Report Steve: I will place all the received document to the DWM document tracking system according to my interpretation of the government document transparency/retention policy even the draft version. If you don’t want the draft CQA in the system just let me know. Ming From: Lamb, Steve [mailto:SLamb@scsengineers.com] Sent: Tuesday, October 04, 2016 12:55 PM To: Chao, Ming-tai <ming.chao@ncdenr.gov> Cc: Murray, John E <john.murray@ncdenr.gov> Subject: Re: Great Oak Landfill - Partial CQA Report Ming The submittal will be draft since the project isn't complete yet. Do you place draft submittals in the document tracking system? John We have no drawings yet. The final survey shots for the top of structural fill just came in today. Steve Sent from my iPhone On Oct 4, 2016, at 12:49 PM, Chao, Ming-tai <ming.chao@ncdenr.gov> wrote: Hi Steve: For the partial CQA report, you are correct that I need a hard copy and an electronic copy (in Pdf format) which will be placed in the document tracking system. Ming Chao Ming-Tai Chao, P.E. Environmental Engineer Permitting Branch, Solid Waste Section NCDEQ, Division of Waste Management (Mailing Address) 5 1646 Mail Service Center Raleigh, NC 27699-1646 (Street Address) Green Square, 217 West Jones Street Raleigh, NC 27603 Tel. 919-707-8251 ming.chao@ncdenr.gov http://portal.ncdenr.org/web/wm/sw <image001.png> E-mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties. From: Lamb, Steve [mailto:SLamb@scsengineers.com] Sent: Tuesday, October 04, 2016 12:41 PM To: Murray, John E <john.murray@ncdenr.gov>; Chao, Ming-tai <ming.chao@ncdenr.gov> Subject: Great Oak Landfill - Partial CQA Report John and Ming We discussed a while back about SCS submitting the CQA Report for Great Oak in parts. The project is at a good point where that makes sense now. All structural fill is tested and in place. And all MQC and CQA data for the geosynthetics is completed. I have the partial report completed and ready to submit. Before I do I wanted to confirm how each of you wanted the report. As I understand, John wants a hard copy and Ming wanted it both electronically and a hard copy. Is that correct? Ming – do you want the narrative in MS Word or is a pdf version OK. Let me know today and I will issue the draft partial report. Thanks, Steve Lamb, PE Vice President SCS Engineers 2520 Whitehall Park Drive, Suite 450 Charlotte, North Carolina 28273 Office – 704.504.3107 Direct - 704-916-1529 Mobile – 704.576.4731