HomeMy WebLinkAbout6029_O'Leary_TRANSFER_FacilityDrawings_DIN26312_20160623C O U R T E S Y F I E L D S E T S - 4 A L U A B - 2 0 A I R B L O W E R 4" UP TO YCO OMC 6" UP TO FCO SP-2 DF WC-2 3" UP TO FD WC-1 4" 2" V UP VTR 3"6" F F 2" 3" 4" 4" 6" 6" 6" 6" 6" 6" 3" SP-1 6" 2" 6" FIRE SUPPLY WATER. SEE CIVIL/ SITE UTILITIES FOR CONTINUATION 3" POTABLE WATER. SEE CIVIL/SITE UTILITIES FOR CONTINUATION. 6" SEDIMENT HOLDING TANK 6" SANITARY SEWER SEE CIVIL/SITE UTILITIES FORCONTINUATION 3" 2" 2" V UP VTR 4" 2" V UPVTR 4" GUTTERS AND DOWNSPOUTS FOR STORM DRAINAGE PIPING TO BE ROUTED ON THE EXTERIOR OF THE BUILDING AND CONNECTED TO STORM SEWER . REFER TO ARCHITECTURAL AND CIVIL PLANS 2" 3" V UP VTR 6" UP TO GCO 6" UP TO GCO 2" UP TO FCO 2" UP TO FCO 4" UP TO FCO 4" UP TO FCO 6" UP TO AD 6" UP TO FCO 6" UP TO AD6" UP TO 2' X 2' X 2' GRATED CATCH BASINWITH AREA DRAIN IN PIT BOTTOM 4" UP TO YCO 4" UP TO YCO 4" 3" UP TO HD 6" UP TO 2' X 2' X 2' GRATED CATCH BASIN WITH AREA DRAIN IN PIT BOTTOM 2" V UP VTR WC-1 WC-2 2" TD TD 6" 4" 2" 4" 3" V UP TO VTR 2" V UP TD 2" V UP 3" V UP 1 1 1 1 1 1 1 3" 3" V UP FOR INFORMATION PURPOSES ONLY. FOUNDATION HAS PREVIOUSLY BEEN APPROVED. 4" 6" 6" 6" 1 1 6" UP TO AD 1 Scale Date 101 W. Worthington Avenue Suite 240 Charlotte, NC 28203 phone: (704) 333-3360 fax: (704) 333-3362 construction@dasarchitecture.com DAS Project Number O'Leary Resource Recovery Center Recyclery & Transfer Station 3301 Darby Avenue Charlotte, North Carolina 28216 Shell/ Core/ Upfit Package CERT. # C-2330 1/8" = 1'-0" P1.10 PLUMBING - UNDERSLAB 10/12/15 SCALE: 0 1/8" = 1'-0"1 PLUMBING - UNDERSLAB No. Description Date 1 CODE CYCLE 1 4/27/2016 1 COURTESY FIELD SET F D P2.10 1 FCO YCO FCO FCO FCO FCO AD AD FCO 1 1/4" CW 2" V UPVTR AD 3" V UP VTR SEDIMENT HOLDING TANK GCO 2" NFHB NFHB GCO NFHBNFHB NFHB 3/4" TO RADIANT HEATER COORDINATE FINAL CONNECTION WITH MECHANICAL CONTRACTOR (TYP) 1-1/4" 1-1/4" 1" 3/4" 1/2" 1/2" TYP G G G G G LAV LAV LAV LAV FD FD PROPOSED GAS METER LOCATION 2" V UP VTR WC-1 WC-2 WC-2 UR BS-1 DF FOR CONTINUATION REFER TO P2.10 YCO YCO FCO 2' X 2' X 2' GRATED CATCH BASIN WITH AREA DRAIN IN PIT BOTTOM 3" HD 3" CW UP 2" 2" V UP 2" HOSE CONNECTION, COORDINATE EXACT LOCATION WITH OWNER REFER TO 2/P.10 2"3/4" 2" HOSE CONNECTION, COORDINATE EXACT LOCATION WITH OWNER REFER TO 2/P.10 2" HOSE CONNECTION, COORDINATE EXACT LOCATION WITH OWNER REFER TO 2/P.10 2" HOSE CONNECTION, COORDINATE EXACT LOCATION WITH OWNER REFER TO 2/P.10 2" 2" NOTE: GAS PIPING IS SIZED BASED ON A LOAD OF 1000 MBH, A DEVELOPED LENGTH OF 400 ', 2 PSI INLET PRESSURE, A 1 PSI PRESSURE DROP, AND TABLE 402.4(3) OF THE NC FUEL GAS CODE. AD 2' X 2' X 2' GRATED CATCH BASIN WITH AREA DRAIN IN PIT BOTTOM UR 3" V UP FDC 6" FIRE UP, REFER TO DETAIL 3/P0.10 AD1 2' X 2' X 2' GRATED CATCH BASIN WITH AREA DRAIN IN PIT BOTTOM 2' X 2' X 2' GRATED CATCH BASIN WITH AREA DRAIN IN PIT BOTTOM Scale Date 101 W. Worthington Avenue Suite 240 Charlotte, NC 28203 phone: (704) 333-3360 fax: (704) 333-3362 construction@dasarchitecture.com DAS Project Number O'Leary Resource Recovery Center Recyclery & Transfer Station 3301 Darby Avenue Charlotte, North Carolina 28216 Shell/ Core/ Upfit Package CERT. # C-2330 1/8" = 1'-0" P1.20 PLUMBING - FIRST FLOOR 10/12/15SCALE: 0 1/8" = 1'-0"1 PLUMBING - FIRST FLOOR No. Description Date 1 CODE CYCLE 1 4/27/2016 COURTESY FIELD SET 1 2 3 4 5 6 7 8 9 10 A E R R 29' - 0"28' - 2"28' - 2"28' - 2"26' - 10"1' - 4"29' - 0"27' - 8"27' - 8" 255' - 0" 15 6 ' - 4 " 2 S2.01 2 S2.02 NOTES: 11 Q P NMM J H G D B B F60 CJ CJ CJ CJ CJ CJ CJ CJ CJ CJ CJ CJ CJ CJ CJ CJ CJ CJ CJ CJ CJ CJ CJ CJ CJ FS FS 5 S2.01 5 S2.01 2 S2.02 1 S2.02 1 S2.04 5 S2.02 1 S2.01 1 S2.03 6 S2.04 1. FINISHED FLOOR ELEVATION IS AT EL.739.00' UNLESS NOTED THUS ( ) THEREFROM. 2. TOP OF FOOTING IS 1'-4" BELOW EL. 739.00 UNLESS NOTED THUS TF( ) FROM EL. 739.00. 3. STRUCTURAL SLAB ON GRADE IS 10 INHCES NORMAL WEIGHT CONCRETE WITH STRUX 90/40 MACRO FIBER REINFORCING 5 POUNDS PER YARD DOSAGE ON VAPOR BARIER OVER 8" COMPACTED CRUSHED STONE COMPACTED TO AT LEAST 98 PERCENT OF ITS STANDARD PROCTOR MAXIMUM DRY DENSITY. 4. "FS" DENOTES FOOTING STEP, SEE TYPICAL DETAIL FOR REINFORCING REQUIREMENTS. 5. "F1 I C1 " DENOTES "FOOTING MARK," "COLUMN MARK," AND "TOP OF FOOTING ELEVATION." "TOP OF FOOTING ELEVATION IS REFERENCED FROM FINISHED FLOOR SEE FOOTING SCHEDULE AND TYPICAL DETAILS. 6. "CJ" DENOTES LOCATION OF CONTROL JOINTS IN SLAB ON GRADE, CONTROL JOIST IN SLAB ON GRADE SHALL BE SAW CUT, CONSTRUCTION JOINTS SHALL BE FORMED WITH KEYED METAL EDGE FORM MATERIAL OR EQUIVALENT. SEE TYPICAL SECTIONS AND DETAILS. 7. F.O.W. DENOTES OUTSIDE FACE OF 8" CIP STEM WALL. 8. O.F.S. DENOTES OUTSIDE FACE OF STUD WALL. F60 F60 F60 F60 F80 F80 F60 F40 F50 F50 F50 F50 F50 F60100 F60100 F60100 F60100 F60100 F60100 F60100 F60100 F30 10" S.O.G. (-VARIES) W/ FIBER REINFORCING OVER 8" COMPACTED CRUSHED STONE 2 S2.04 (-7'-0") (-7'-0") 12 13 14 18' - 6" 4' - 0"13' - 4"1' - 2"29' - 0" 6 S2.01 TF(-3'-8") -5'-0" TF ( - 5 ' - 0 " ) TF ( - 5 ' - 0 " ) FS TF(-3'-8") FS -5'-0" P.1 B.9 8" 4 S2.02 6 S2.04 3 S2.03 3 S2.03 F40 F40 F50 F50 F40 C1 C1 F50 8 S2.02 2' - 0"2' - 0" 12" THICK EQUIPMENT FOUNDATION W/ #5 AT 12" O.C. TOP AND BOTTOM EA. WAY W/ 1/2" RECESS JOINT FILLER ALL AROUND, GC COORDINATEDIMENSION OF PAD WITH EQUIPMENT SUPPLIER1 S2.05 2 S2.05 10' - 8"10' - 4"10' - 0"10' - 2"10' - 7"10' - 7" SUMP PUMP IN SLAB BY OTHERS SUMP PUMP IN SLAB BY OTHERS 7 S2.02 F60 CJ CJ CJ CJ CJ CJ CJ CJ CJ 10' - 0" 60 ' - 7 " 30' - 11 5/8" 71 ' - 2 " 24 ' - 6 " 15'-8".4' - 8" F50 F50 F50 F66 F50 F50 F66 FS TF 0 ' - 0 " TF 0'-0" TF 0 ' - 8 " TF (1'-4")TF (1'-4") TF ( 0 ' - 8 " ) TF (0'-8")TF (0'-8") TF 0 ' - 0 " FS TF 0 ' - 0 " 3' - 4 " -8"-12"-8"-12"-8"7' - 6" 18" WID TRAFFIC RATED TRENCH DRAIN MHD-18 WITH GALV. GRATE 1 S2.03 2 S2.03 5 S2.03 4 S2.03 4 S2.04 3 S2.04 5 S2.04 4 S2.01 2A S2.03 5A S2.03 F.D. F.D. 3 S2.05 4 S2.05 20' - 6"9' - 6" 17 ' - 0 " 24 ' - 0 " 7' - 0 " 30' - 0" S2.01 3 CONVEYOR PIT APPROX. 65'-0" X 10'-0" X 7'-0" DEEP, SEE 1 ON S1.02 5' - 4"6 7/8" 5' - 4 " 5' - 4 " 5' - 4" CJ CJ CJ 2-#7 TIE BARS EA. COLUMN W/ BAR LOCK SPLICE 2-#7 TIE BARS EA. COLUMN W/ BAR LOCK SPLICE 739.00 739.00 739.00 739.00 739.00 739.00 739.00 739.00 739.00 739.00 738.75 TF(-5'-0") 23 ' - 4 " 25 ' - 0 " 25 ' - 0 " 25 ' - 0 " 23 ' - 0 " 12 1 ' - 4 " 35 ' - 0 " 7' - 2 " 23 ' - 2 " 25 ' - 8 " 19 ' - 4 " 20 ' - 8 " 25 ' - 4 " 12 ' - 1 0 " 12 ' - 1 0 " 19 ' - 4 " 20 ' - 0 " 52' - 6" 3 S2.02 2 S2.01 6 S2.01 FS TF(-2'-4") 4'- 0 " M I N . 4' - 0 " M I N . FS TF(-2'-4") 4'-0" MIN.4'-0" MIN. FS TF ( - 0 ' - 8 " ) -0'-11" -0'-11" -0'-11" -0'-0" -0'-0"0'-0"0'-0"0'-0"0'-0"0'-0" 0'-0"0'-0"0'-0"0'-0"-0'-0" -0'-0" -0'-0" -0'-0" -0'-0" -0'-0" -0'-0" F.O.W. F.O.W. F.O.W.F.O.W. F.O.S. F. O . W . F. O . W . F. O . W . F. O . S . O.F OF BRICK TO MATCH O.F. BRICK AT BUILDING MHD-12 TRENCH DRAIN 6 S2.02 6 S2.02 6 S2.02 6 S2.02 6 S2.02 FS FS TF (0'-8")TF (0'-8") FS 738.75 738.75 738.75 738.75 738.75 738.75 738.75 739.40 740.50 740.50 4" S.O.G. (740.50) W/ FIBER REINFORCING ON VAPOR BARRIER OVER 4" POUROUS FILL F.O.S. 741.00 741.00 741.00 741.00 741.00 741.50 741.50 741.50 741.50 S2.03 6 3 S2.05 S2.05 5 7 S2.03 7 S2.03 S1.03 1 S1.03 2 10.3 1 S2.07 25 ' - 0 " 21 ' - 0 " . 33 3 3 1' - 4" 1' - 4 " 3 3 3 6' - 1 7/8" 3 27' - 4" 1' - 4" 3 1' - 4 " 3 CJ CJ C J CJ 5' - 1 1 " . 12 ' - 0 " 20 ' - 2 " . 4' - 0 " 9'-2".10' - 0"9' - 0" 36 ' - 2 " . 7'- 1 1 " . 10'-0". 8".9'-4". 12 ' - 1 " . 25 ' - 0 " 25 ' - 0 " 4'- 5 " . 66 ' - 6 " . 3 3 3 3 6' - 2" 5' - 4 " 6' - 2" 3 F.D. 3 F.D. 3 FS TF 0 ' - 0 " 3 3 3 3 3 3 3 FS 12' - 0"18'-3 5/8".10'-0". 17 ' - 2 " . F.D. 4 4 4 4 4 4 4 4' - 8 " 4 4 F50 4 4 Date 101 W. Worthington Avenue Suite 240 Charlotte, NC 28203 phone: (704) 333-3360 fax: (704) 333-3362 construction@dasarchitecture.com DAS Project Number O'Leary Resource Recovery Center Charlotte, North Carolina Shell / Core / Upfit Package Structures INC. Ph: 704-662-6844 Mooresville, N.C. 28117 150 Fairview Road Suite 330 Email: jim@structureinc.com Firm Number C-1066 S1.01 FLOOR PLAN 04/06/16 14 205 00 04/06/16 3/32" = 1'-0"1 FLOOR PLAN No. Description Date 3 BD-SC.001 05.20.16 4 BD-SC.002 06.01.16 COURTESY FIELD SET Level 1 - Front 0' - 0" Eave 36' - 0" 2 3 4 5 8 9 10 111 2 A6.02 Level 2 14' - 0" 3 A6.02 1 A6.022 A6.52 1 A6.03 6 A6.54 3 Sim 7 TIPPING FLOOR 113 1 A6.52 12 ' - 6 " 1 2 3 567 8 1 9 11 A6.58 3 12 13 14 7' - 0 " Conveyor Pits -7' - 0" Rear Cols. 1-6 2' - 0" Rear Cols. 7-11 2' - 6" Level 1 - Offices 1' - 6" 2 A6.03 7' - 0 " CONVEYOR BY OTHERS CLOSURE PLATES 5' - 0 " 2'- 0 " CONVEYOR PIT CONVEYOR BY OTHERS CLOSURE PLATES 5' - 0 " 2'- 0 " CONVEYOR PIT 7' - 0 " 7' - 0 " 29'-0"28'-2"28'-2"28'-2"26'-10"1'-4"29'-0"27'-8"27'-8"29'-0"1'-2" 13'-4"4'-0" CATWALK/PLATFORM DIAGONAL CROSS BRACING DIAGONAL CROSS BRACING 333 LEVEL 2OFFICES LEVEL 1 OFFICES UNOCCUPIED SPACE Level 1 - Front 0' - 0" Eave 36' - 0" 2 3 4 5 8 9 10 111 2 A6.02 Level 2 14' - 0" 3 A6.02 1 A6.022 A6.52 1 A6.03 6 7 TIPPING FLOOR 113 1 A6.52 A6.54 3 Sim D E 1 2 3 8 9 11 1 2 5 67 12 13 14 A6.54 4 7' - 0 " 2'- 6 " 7' - 0 " Conveyor Pits -7' - 0" Rear Cols. 1-6 2' - 0" Rear Cols. 7-11 2' - 6" Level 1 - Offices 1' - 6" 10' HIGH CONCRETE PUSH WALLS 2 A6.03 CONVEYOR BY OTHERS CLOSURE PLATES 5' - 0 " 2' - 0 " CONVEYOR PIT 7' - 0 " CONVEYOR BY OTHERS CLOSURE PLATES 5' - 0 " 2' - 0 " CONVEYOR PIT 7' - 0 " 29'-0"28'-2"28'-2"28'-2"26'-10"1'-4"29'-0"27'-8"27'-8"29'-0"1'-2" 13'-4"4'-0" A6.56 3 A6.56 3 EQUIPMENT SHOWN FOR REFERENCE ONLY. REFER TO MACHIENEX EQUIPMENT DRAWINGS FOR DETAILED EQUIPMENT INFORMATION CATWALK/ PLATFORM DIAGONAL CROSS BRACING DIAGONAL CROSS BRACING 333 3 3 3 A6.56 3 A6.56 3 EQUIPMENT SHOWN FOR REFERENCE ONLY. REFER TO MACHIENEX EQUIPMENT DRAWINGS FOR DETAILED EQUIPMENT INFORMATION BUILDING SYSTEMS KEYNOTES 1 MASONRY/ CONCRETE WATERTABLE: 1. BRICK VENEER W/ ADJ. 2-PC. GALV. STL. ANCHORS & SPRAY-APPLIED WATER REPELLENT 2. NOMINAL 1" CAVITY (AIRSPACE) 3. 1.5" XPS RIGID FOAM BOARD INSULATING SHEATHING (R7.5) 4. REINFORCED 8" CONCRETE WALL - SEE STRUCTURAL DWG'S. 5. BASE OF CAVITY: THROUGHWALL FLASHING, MORTAR NET & OPEN HEAD JOINT WEEPS @ 24" O.C. PROVIDE OPEN HEAD JOINT INSULATED METAL ROOF SYSTEM (SEE METAL BUILDING DRAWINGS) : 1. PRE-FINISHED METAL ROOF PANELS W/ INTEGRAL SKYLIGHT PANELS (SEE ROOF PLAN, RCP PLAN, METAL BLDG. DWGS.)2. CEE/ ZEE PURLINS 3. R-11 INSULATION (3 1/2" BATTS, 6" BATTS WITH THERMAL BLOCKS) 4. VAPOR/ WEATHER BARRIER 5. PLASTIC LINER SHEET 2 INSULATED METAL WALL SYSTEM (SEE METAL BUILDING DRAWINGS):1. PRE-FINISHED METAL WALL PANEL 2. CEE/ ZEE GIRTS 3. R-19 INSULATION (8" BATTS) 4. VAPOR/ WEATHER BARRIER 5. PRE-FINISHED METAL WALL PANEL 3 DOCK RETAINING WALLS (SEE STRUCTURAL): 1. REINFORCED CAST-IN-PLACE CONCRETE W/ BRICK VENEER (WHERE INDICATED)4 8 11 GUTTERS & DOWNSPOUTS (SEE METAL BUILDING DRAWINGS) : 1. PRE-FINISHED ALUMINUM GUTTERS 2. PRE-FINISHED ALUMINUM DOWNSPOUTS TIED TO UNDERGROUND, SEE CIVIL OFFICE WALL: 1. BRICK VENEER W/ ADJ. 2-PC. GALV. STL. ANCHORS & SPRAY-APPLIED WATER REPELLENT 2. NOMINAL 2" CAVITY (AIRSPACE) 3. 5/8" DENSGLASS EXTERIOR SHEATHING 4. 6" METAL STUDS UP TO 28'-0" AFF AND CEE/ ZEE GIRTS 28'-0" AND ABOVE 5. R-19 INSULATION (8" BATTS) 6. VAPOR/ WEATHER BARRIER 7. 5/8" GWB, PAINTED NOT USED7 BUILDING SLAB (TYPE 1) (SEE STRUCTURAL) : 1. 10" FIBER REINFORCED CONCRETE S.O.G. W/ CONTROL JOINTS 2. 4" COMPACTED CRUSHED STONE 3. COMPACTED SUB-GRADE 5 EXTERIOR SLAB (SEE CIVIL): 1. 7" REINFORCED CONCRETE S.O.G. W/ CONTROL JOINTS 2. 7 1/2" COMPACTED CRUSHED STONE 6 12 BUILDING SLAB (TYPE 3) (SEE STRUCTURAL) : AT OFFICES 1. 4" REINFORCED CONCRETE S.O.G. W/ CONTROL JOINTS 2. VAPOR BARRIER 3. 4" COMPACTED CRUSHED STONE 4. COMPACTED SUB-GRADE 9 BOLLARDS: 1. 10" CONCRETE FILLED STEEL PIPE BOLLARD, PRIMED AND PAINTED 2. 28" DIA. 3000# CONCRETE FILLED ANCHOR BLOCK. FILL TO UNDERSIDE OF PAVEMENT 10 FOOTINGS & FOUNDATIONS (SEE STRUCTURAL): 1. REINFORCED CONCRETE FOOTINGS/ FOUNDATIONS (SEE STRUCTURAL) Scale Date 101 W. Worthington Avenue Suite 240 Charlotte, NC 28203 phone: (704) 333-3360 fax: (704) 333-3362 construction@dasarchitecture.com DAS Project Number O'Leary Resource Recovery Center 3307 Darby Avenue Charlotte, North Carolina 28216 Shell/ Core/ Upfit Package 04.14.2016 As indicated A6.01 Building Sections 04/06/2016 14 205 00 1/8" = 1'-0"2 Building Section 2 1/8" = 1'-0"1 Building Section 1 No. Description Date 5 BD-SC.001 05/20/16 5 5 COURTESY FIELD SET Level 1 - Front 0' - 0" Eave 36' - 0" RA 2 A6.01 1 A6.01 3 A6.03 1 A6.57 2 A6.57 1 A6.58 D H M QCEGJNP A6.51 3 Sim 1 1 3 3 45 6 6 8 8 5 B.9 P.1 A6.52 4 Sim Rear Cols. 1-6 2' - 0" Rear Cols. 7-11 2' - 6" Level 1 - Offices 1' - 6" B 35'-0"7'-2" 8"15'-6"7'-0"12'-10"5'-2" 7'-8"17'-4"2'-0"20'-0"3'-0"23'-0" 36 ' - 0 " TRAFFIC RAIL GUARDRAIL/ HANDRAIL OFFICE FLOOR 5 A6.55 Level 1 - Front 0' - 0" Eave 36' - 0" RA 2 A6.01 3 A6.54 2 A6.54 1 A6.01 3 A6.03 D H M Q A6.52 2 Sim C E G J N P 1 1 2 3 3 5 6 8 8 B.9 P.1 Rear Cols. 1-6 2' - 0" Rear Cols. 7-11 2' - 6" Level 1 - Offices 1' - 6" GRAVEL, SEE CIVIL 3' HIGH CONCRETE WALL BIN BLOCK WALL, BY OWNER 10' HIGH CONCRETE PUSH WALL 10' HIGH CONCRETE PUSH WALL WITH DEFLECTOR PLATE CONCRETE WALL B 35'-0"7'-2" 8"15'-6"7'-0"12'-10"5'-2" 7'-8"17'-4"2'-0"20'-0"3'-0"23'-0" 36 ' - 0 " A6.51 4 Sim BUILDING SYSTEMS KEYNOTES 1 MASONRY WATERTABLE: 1. BRICK VENEER W/ ADJ. 2-PC. GALV. STL. ANCHORS & SPRAY-APPLIED WATER REPELLENT 2. NOMINAL 1" CAVITY (AIRSPACE) 3. 1.5" XPS RIGID FOAM BOARD INSULATING SHEATHING (R7.5) 4. REINFORCED 8" CMU WALL, PAINTED - SEE STRUCTURAL DWG'S. 5. BASE OF CAVITY: THROUGHWALL FLASHING, MORTAR NET & OPEN HEAD JOINT WEEPS @ 24" O.C. PROVIDE OPEN HEAD JOINT INSULATED METAL ROOF SYSTEM (SEE METAL BUILDING DRAWINGS) : 1. PRE-FINISHED METAL ROOF PANELS W/ INTEGRAL SKYLIGHT PANELS (SEE ROOF & RCP PLAN) 2. CEE/ ZEE PURLINS 3. R-11 INSULATION (3 1/2" BATTS, 6" BATTS WITH THERMAL BLOCKS) 4. VAPOR/ WEATHER BARRIER 5. PLASTIC LINER SHEET 2 INSULATED METAL WALL SYSTEM (SEE METAL BUILDING DRAWINGS): 1. PRE-FINISHED METAL WALL PANEL 2. CEE/ ZEE GIRTS 3. R-19 INSULATION (8" BATTS) 4. VAPOR/ WEATHER BARRIER 5. PRE-FINISHED METAL WALL PANEL 3 DOCK RETAINING WALLS (SEE STRUCTURAL): 1. REINFORCED CAST-IN-PLACE CONCRETE W/ BRICK VENEER (WHERE INDICATED) BUILDING SLAB (TYPE 1) (SEE STRUCTURAL) : 1. 10" FIBER REINFORCED CONCRETE S.O.G. W/ CONTROL JOINTS 2. 4" COMPACTED CRUSHED STONE 3. COMPACTED SUB-GRADE 5 EXTERIOR SLAB (SEE CIVIL): 1. 7" REINFORCED CONCRETE S.O.G. W/ CONTROL JOINTS 2. 7 1/2" COMPACTED CRUSHED STONE 6 4 NOT USED7 12 BUILDING SLAB (TYPE 3) (SEE STRUCTURAL) : AT OFFICES 1. 4" REINFORCED CONCRETE S.O.G. W/ CONTROL JOINTS 2. VAPOR BARRIER 3. 4" COMPACTED CRUSHED STONE 4. COMPACTED SUB-GRADE 9 10 8 11 GUTTERS & DOWNSPOUTS (SEE METAL BUILDING DRAWINGS) : 1. PRE-FINISHED ALUMINUM GUTTERS 2. PRE-FINISHED ALUMINUM DOWNSPOUTS TIED TO UNDERGROUND, SEE CIVIL BOLLARDS: 1. 10" CONCRETE FILLED STEEL PIPE BOLLARD, PRIMED AND PAINTED 2. 28" DIA. 3000# CONCRETE FILLED ANCHOR BLOCK. FILL TO UNDERSIDE OF PAVEMENT FOOTINGS & FOUNDATIONS (SEE STRUCTURAL): 1. REINFORCED CONCRETE FOOTINGS/ FOUNDATIONS (SEE STRUCTURAL) OFFICE WALL: 1. BRICK VENEER W/ ADJ. 2-PC. GALV. STL. ANCHORS & SPRAY-APPLIED WATER REPELLENT 2. NOMINAL 2" CAVITY (AIRSPACE) 3. 5/8" DENSGLASS EXTERIOR SHEATHING 4. 6" METAL STUDS UP TO 28'-0" AFF AND CEE/ ZEE GIRTS 28'-0" AND ABOVE 5. R-19 INSULATION (8" BATTS)6. VAPOR/ WEATHER BARRIER 7. 5/8" GWB, PAINTED Level 1 - Front 0' - 0" Eave 36' - 0" RA 2 A6.01 2 A6.54 1 A6.01 3 A6.03 D H M Q A6.51 4 Sim C E G J N P 1 2 3 1 2 3 5 5 6 6 8 8 9 B.9 P.1 A6.51 1 Sim Rear Cols. 1-6 2' - 0" Rear Cols. 7-11 2' - 6" Level 1 - Offices 1' - 6" GRAVEL, SEE CIVIL5 CONCRETE WALL B 35'-0"7'-2" 8"15'-6"7'-0"12'-10"5'-2" 7'-8"17'-4"2'-0"20'-0"3'-0"23'-0" 34 ' - 6 " 17 ' - 6 " 13 ' - 0 " INFRARED HEATERS SEE RCP PLAN FOR LOCATIONS HIGHBAY FIXTURES SEE RCP PLAN FOR LOCATIONS INTEGRAL SKYLIGHTS PRIMARY CATWALK/ PLATFORM ELEVATION30 ' - 0 " 2' - 0 " MECH. DUCTWORK SEE MECH. PLAN FOR LOCATIONS LIGHTS MOUNTED TO UNDERSIDE OF CATWALK SEE RCP PLAN FOR LOCATIONS LIGHTS OVER CATWALK SEE RCP PLAN FOR LOCATIONS 24 ' - 0 " 32 ' - 0 " Scale Date 101 W. Worthington Avenue Suite 240 Charlotte, NC 28203 phone: (704) 333-3360 fax: (704) 333-3362 construction@dasarchitecture.com DAS Project Number O'Leary Resource Recovery Center 3307 Darby Avenue Charlotte, North Carolina 28216 Shell/ Core/ Upfit Package 04.14.2016 As indicated A6.02 Building Sections 04/06/2016 14 205 00 1/8" = 1'-0"1 Building Section 3 1/8" = 1'-0"2 Building Section 4 No. Description Date 5 BD-SC.001 05/20/16 1/8" = 1'-0"3 Building Section 5 5 5 COURTESY FIELD SET BUILDING SYSTEMS KEYNOTES 1 MASONRY WATERTABLE: 1. BRICK VENEER W/ ADJ. 2-PC. GALV. STL. ANCHORS & SPRAY-APPLIED WATER REPELLENT 2. NOMINAL 1" CAVITY (AIRSPACE) 3. 1.5" XPS RIGID FOAM BOARD INSULATING SHEATHING (R7.5) 4. REINFORCED 8" CMU WALL, PAINTED - SEE STRUCTURAL DWG'S. 5. BASE OF CAVITY: THROUGHWALL FLASHING, MORTAR NET & OPEN HEAD JOINT WEEPS @ 24" O.C. PROVIDE OPEN HEAD JOINT INSULATED METAL ROOF SYSTEM (SEE METAL BUILDING DRAWINGS) : 1. PRE-FINISHED METAL ROOF PANELS W/ INTEGRAL SKYLIGHT PANELS (SEE ROOF & RCP PLAN) 2. CEE/ ZEE PURLINS 3. R-11 INSULATION (3 1/2" BATTS, 6" BATTS WITH THERMAL BLOCKS) 4. VAPOR/ WEATHER BARRIER 5. PLASTIC LINER SHEET 2 INSULATED METAL WALL SYSTEM (SEE METAL BUILDING DRAWINGS): 1. PRE-FINISHED METAL WALL PANEL 2. CEE/ ZEE GIRTS 3. R-19 INSULATION (8" BATTS)4. VAPOR/ WEATHER BARRIER 5. PRE-FINISHED METAL WALL PANEL 3 DOCK RETAINING WALLS (SEE STRUCTURAL): 1. REINFORCED CAST-IN-PLACE CONCRETE W/ BRICK VENEER (WHERE INDICATED) BUILDING SLAB (TYPE 1) (SEE STRUCTURAL) : 1. 10" FIBER REINFORCED CONCRETE S.O.G. W/ CONTROL JOINTS 2. 4" COMPACTED CRUSHED STONE 3. COMPACTED SUB-GRADE 5 EXTERIOR SLAB (SEE CIVIL):1. 7" REINFORCED CONCRETE S.O.G. W/ CONTROL JOINTS 2. 7 1/2" COMPACTED CRUSHED STONE 6 4 NOT USED7 12 BUILDING SLAB (TYPE 3) (SEE STRUCTURAL) : AT OFFICES 1. 4" REINFORCED CONCRETE S.O.G. W/ CONTROL JOINTS 2. VAPOR BARRIER 3. 4" COMPACTED CRUSHED STONE 4. COMPACTED SUB-GRADE 9 10 8 11 GUTTERS & DOWNSPOUTS (SEE METAL BUILDING DRAWINGS) : 1. PRE-FINISHED ALUMINUM GUTTERS 2. PRE-FINISHED ALUMINUM DOWNSPOUTS TIED TO UNDERGROUND, SEE CIVIL BOLLARDS: 1. 10" CONCRETE FILLED STEEL PIPE BOLLARD, PRIMED AND PAINTED 2. 28" DIA. 3000# CONCRETE FILLED ANCHOR BLOCK. FILL TO UNDERSIDE OF PAVEMENT FOOTINGS & FOUNDATIONS (SEE STRUCTURAL): 1. REINFORCED CONCRETE FOOTINGS/ FOUNDATIONS (SEE STRUCTURAL) OFFICE WALL: 1. BRICK VENEER W/ ADJ. 2-PC. GALV. STL. ANCHORS & SPRAY-APPLIED WATER REPELLENT 2. NOMINAL 2" CAVITY (AIRSPACE) 3. 5/8" DENSGLASS EXTERIOR SHEATHING 4. 6" METAL STUDS UP TO 28'-0" AFF AND CEE/ ZEE GIRTS 28'-0" AND ABOVE 5. R-19 INSULATION (8" BATTS) 6. VAPOR/ WEATHER BARRIER 7. 5/8" GWB, PAINTED Level 1 - Front 0' - 0" Eave 36' - 0" R A Level 2 14' - 0" 2 A6.01 1 A6.01 3 A6.03 1 A6.57 2 A6.57 1 A6.58 DHMQ 9' - 1 0 " 2 ' - 8 " CEGJNP A6.58 2 A6.57 3 A109a A108 A106 A206 A105 A101A B 1 1 2 2 3 3 4 5 12 8 8 11 11 5 B.9P.1 8' - 4 " 10 ' - 4 " UNOCCUPIED SPACE HKH 1 H H 2' - 0 " 5' - 4 " 3'- 0 " H Rear Cols. 1-6 2' - 0" Rear Cols. 7-11 2' - 6" Level 1 - Offices 1' - 6" A104A107 B 35'-0"7'-2"8"15'-6"7'-0"12'-10"5'-2"7'-8"17'-4"2'-0"20'-0"3'-0"23'-0" 22 ' - 0 " 12 ' - 6 " 36 ' - 0 " 28' - 0" 27 ' - 0 " 4 DIAGONAL CROSS BRACING INSIDE BUILDING, DASHED FOR REFERENCE 5 A6.55 Level 1 - Front 0' - 0" Eave 36' - 0" 8 9 10 11 4 A6.52 4 A6.53 1 A6.02 6 7 A6.54 2 Sim 3 A6.52 A6.55 4 A124 1 2 3 5 6 9 3 2 1 9A125A126 12 Rear Cols. 1-6 2' - 0" Rear Cols. 7-11 2' - 6" Level 1 - Offices 1' - 6" TRAFFIC RAIL 8' - 0 " 3' - 0 " 3 ' - 0 " 2 ' - 0 " 10'-0"10'-0"10'-0"10'-0"10'-0" 2 A6.03 1'-4" 29'-0" 27'-8" 27'-8" 29'-0" 1'-2" DIAGONAL CROSS BRACING 333 Level 1 - Front 0' - 0" Eave 36' - 0" RA Level 2 14' - 0" 2 A6.01 Docks -4' - 0" 1 A6.01 3 A6.03 1 A6.57 2 A6.57 1 A6.58 D H M QCEGJNPB.9 P.1 Rear Cols. 1-6 2' - 0" Rear Cols. 7-11 2' - 6" Level 1 - Offices 1' - 6" A101 A104 A105 A106 A107 A108 A109a A206 HH HKHHB A CATWALK A6.53 1 Sim A6.52 4 Sim 1 1 3 3 4 5 5 12 6 6 8 8 9 B 35'-0"7'-2" 8" 15'-6"7'-0"12'-10"5'-2" 7'-8"17'-4"2'-0"20'-0"3'-0"23'-0" 22 ' - 0 " 12 ' - 6 " 1' - 6 " 4 ' - 0 " 28' - 0" 1 4 DIAGONAL CROSS BRACING 2' - 6 " 11 ' - 6 " METAL FRAMED SOFFIT AROUND MEZZANINE GIRDER WRAPPED WITH METAL TO MATCH EXTERIOR EYEBROW CANOPIES 1'- 0 " 1'- 6 " 5 A6.55 ALUM. ALUM. HM.HM.HM.HM.HM.HM. Scale Date 101 W. Worthington Avenue Suite 240 Charlotte, NC 28203 phone: (704) 333-3360 fax: (704) 333-3362 construction@dasarchitecture.com DAS Project Number O'Leary Resource Recovery Center 3307 Darby Avenue Charlotte, North Carolina 28216 Shell/ Core/ Upfit Package 04.14.2016 As indicated A6.03 Building Sections 04/06/2016 14 205 00 No. Description Date 5 BD-SC.001 05/20/16 1/8" = 1'-0"1 Building Section 6 1/8" = 1'-0"3 Building Section 8 1/8" = 1'-0"2 Building Section 7 5 5 COURTESY FIELD SET Level 1 - Front 0' - 0" Eave 36' - 0" R A7.01 1 A7.01 2 5. EXTERIOR SLAB (SEE CIVIL) 2. MASONRY WATERTABLE PREFAB METAL BUILDING, SEE METAL BUILDING DWG'S STEEL LINE 3. INSULATED METAL WALL SYSTEM 1. INSULATED METAL ROOF SYSTEM 8. GUTTERS & DOWNSPOUTS 6. BUILDING SLAB TYPE 1 10. FOOTINGS & FOUNDATIONS PREFAB SKYLIGHT BY MANUFACTURER REINF. CONCRETE IMPACT WALL, BEYOND 4'-8" 1'-4"3'-4" 1' - 4 " 4' - 4 " Level 1 - Front 0' - 0" Eave 36' - 0" R A7.03 3 A7.01 2 5. EXTERIOR SLAB (SEE CIVIL) 2. MASONRY WATERTABLE PREFAB METAL BUILDING, SEE METAL BUILDING DWG'S STEEL LINE 3. INSULATED METAL WALL SYSTEM 1. INSULATED METAL ROOF SYSTEM 8. GUTTERS & DOWNSPOUTS 9. BOLLARD BEYOND 6. BUILDING SLAB TYPE 1 10. FOOTINGS & FOUNDATIONS PREFAB SKYLIGHT BY MANUFACTURER REINF. CONCRETE IMPACT WALL 4' - 4 " 4'-8" 1'-4" 1'-8" 1'-4"3'-4" 1' - 4 " 1' - 1 " Level 1 - Front 0' - 0" Eave 36' - 0" RA7.01 2 A7.03 6 HOLLOW METAL DOOR WITH VISION LITE AND TRANSOM, PAINTED 5. EXTERIOR SLAB (SEE CIVIL) 2. MASONRY WATERTABLE BEYOND PREFAB METAL BUILDING, BEYOND. SEE METAL BUILDING DWG'S STEEL LINE 3. INSULATED METAL WALL SYSTEM 1. INSULATED METAL ROOF SYSTEM 8. GUTTERS & DOWNSPOUTS 9. BOLLARD, BEYOND 6. BUILDING SLAB TYPE 1 10. FOOTINGS & FOUNDATIONS SEE DOOR HEAD DETAILS. TRIM BY MTL. BLDG. MFR. PREFAB SKYLIGHT BY MANUFACTURER REINF. CONCRETE IMPACT WALL, BEYOND 1'-4"3'-4" 4'-8" 4' - 4 " LOUVER Level 1 - Front 0' - 0" Eave 36' - 0" R 24 ' - 0 " WATER DEFLECTOR- 2" HIGH, 2'-0" WIDE BY LENGTH OF DOOR. TYP. ALL ROLL-UP DOORS. CENTERED ON OVERHEAD DOOR. SEE STRUCT. DWG'S OVERHEAD ROLLING DOOR 5. EXTERIOR SLAB (SEE CIVIL) PREFAB METAL BUILDING, SEE METAL BUILDING DWG'S STEEL LINE 3. INSULATED METAL WALL SYSTEM 1. INSULATED METAL ROOF SYSTEM 6. BUILDINGSLAB TYPE 1 OVERHEAD ROLLINGDOOR STEEL JAMB, PAINTED 2. MASONRY WATERTABLE, BEYOND 8. GUTTERS & DOWNSPOUTS 9. BOLLARDS 10. FOOTINGS & FOUNDATIONS A7.03 1 PREFAB SKYLIGHT BY MANUFACTURER 1'-8". 1'-4"3'-4" 4' - 4 " 4'-8" REINF. CONCRETE IMPACT WALL,BEYOND A7.01 2 10"2'-0" 1/2" 1' - 4 " 1' - 0 " OVERHEAD DOOR EQUIPMENT BUILDING SYSTEMS KEYNOTES 1 MASONRY/ CONCRETE WATERTABLE: 1. BRICK VENEER W/ ADJ. 2-PC. GALV. STL. ANCHORS & SPRAY-APPLIED WATER REPELLENT 2. NOMINAL 1" CAVITY (AIRSPACE) 3. 1.5" XPS RIGID FOAM BOARD INSULATING SHEATHING (R7.5) 4. REINFORCED 8" CONCRETE WALL - SEE STRUCTURAL DWG'S. 5. BASE OF CAVITY: THROUGHWALL FLASHING, MORTAR NET & OPEN HEAD JOINT WEEPS @ 24" O.C. PROVIDE OPEN HEAD JOINT INSULATED METAL ROOF SYSTEM (SEE METAL BUILDING DRAWINGS) : 1. PRE-FINISHED METAL ROOF PANELS W/ INTEGRAL SKYLIGHT PANELS (SEE ROOF PLAN, RCP PLAN, METAL BLDG. DWGS.) 2. CEE/ ZEE PURLINS 3. R-11 INSULATION (3 1/2" BATTS, 6" BATTS WITH THERMAL BLOCKS) 4. VAPOR/ WEATHER BARRIER 5. PLASTIC LINER SHEET 2 INSULATED METAL WALL SYSTEM (SEE METAL BUILDING DRAWINGS): 1. PRE-FINISHED METAL WALL PANEL 2. CEE/ ZEE GIRTS 3. R-19 INSULATION (8" BATTS) 4. VAPOR/ WEATHER BARRIER 5. PRE-FINISHED METAL WALL PANEL 3 DOCK RETAINING WALLS (SEE STRUCTURAL): 1. REINFORCED CAST-IN-PLACE CONCRETE W/ BRICK VENEER (WHERE INDICATED)4 8 11 GUTTERS & DOWNSPOUTS (SEE METAL BUILDING DRAWINGS) : 1. PRE-FINISHED ALUMINUM GUTTERS 2. PRE-FINISHED ALUMINUM DOWNSPOUTS TIED TO UNDERGROUND, SEE CIVIL OFFICE WALL: 1. BRICK VENEER W/ ADJ. 2-PC. GALV. STL. ANCHORS & SPRAY-APPLIED WATER REPELLENT 2. NOMINAL 2" CAVITY (AIRSPACE) 3. 5/8" DENSGLASS EXTERIOR SHEATHING 4. 6" METAL STUDS UP TO 28'-0" AFF AND CEE/ ZEE GIRTS 28'-0" AND ABOVE 5. R-19 INSULATION (8" BATTS) 6. VAPOR/ WEATHER BARRIER 7. 5/8" GWB, PAINTED NOT USED7 BUILDING SLAB (TYPE 1) (SEE STRUCTURAL) : 1. 10" FIBER REINFORCED CONCRETE S.O.G. W/ CONTROL JOINTS 2. 4" COMPACTED CRUSHED STONE 3. COMPACTED SUB-GRADE 5 EXTERIOR SLAB (SEE CIVIL): 1. 7" REINFORCED CONCRETE S.O.G. W/ CONTROL JOINTS 2. 7 1/2" COMPACTED CRUSHED STONE 6 12 BUILDING SLAB (TYPE 3) (SEE STRUCTURAL) : AT OFFICES 1. 4" REINFORCED CONCRETE S.O.G. W/ CONTROL JOINTS 2. VAPOR BARRIER 3. 4" COMPACTED CRUSHED STONE 4. COMPACTED SUB-GRADE 9 BOLLARDS: 1. 10" CONCRETE FILLED STEEL PIPE BOLLARD, PRIMED AND PAINTED 2. 28" DIA. 3000# CONCRETE FILLED ANCHOR BLOCK. FILL TO UNDERSIDE OF PAVEMENT 10 FOOTINGS & FOUNDATIONS (SEE STRUCTURAL): 1. REINFORCED CONCRETE FOOTINGS/ FOUNDATIONS (SEE STRUCTURAL) Scale Date 101 W. Worthington Avenue Suite 240 Charlotte, NC 28203 phone: (704) 333-3360 fax: (704) 333-3362 construction@dasarchitecture.com DAS Project Number O'Leary Resource Recovery Center 3307 Darby Avenue Charlotte, North Carolina 28216 Shell/ Core/ Upfit Package 04.14.2016 As indicated A6.51 Wall Sections - Metal Building (Front Wall) 04/06/2016 14 205 00 1/2" = 1'-0"1 Wall Section - Typical at Metal Building Wall 1/2" = 1'-0"2 Wall Section - Typical at Metal Building Column 1/2" = 1'-0"3 Wall Section - Typical at Hollow Metal Door 1/2" = 1'-0"4 Wall Section - Typical at Sectional Roll-Up Door No. Description Date 5 BD-SC.001 05/20/16 5 5 COURTESY FIELD SET Eave 36' - 0" A7.01 2 STEEL LINE 1. INSULATED METAL ROOF SYSTEM 8. GUTTERS & DOWNSPOUTS PREFAB METAL BUILDING, SEE METAL BUILDING DWG'S 3. INSULATED METAL WALL SYSTEM 2. MASONRY WATERTABLE 5. EXTERIOR SLAB (SEE CIVIL) 10. FOOTINGS & FOUNDATIONS STEEL DEFLECTOR PLATE, SEE STRUCTURAL FLASHING/ TRIM AT METAL PLATE BY METAL BLDG. MFR. 6. BUILDING SLAB TYPE 1 B.9 A7.04 5 Rear Cols. 1-6 2' - 0" B GRAVEL ACCESS AREA, SEE CIVIL DWG'S 7' - 0 " 10 ' - 0 " 4' - 0 " REINF. CONCRETE PUSHWALL WITH STEEL PLATE TO 4'-0" AFF, SEE STRUCTURAL LOUVER Eave 36' - 0" STEEL LINE 1. INSULATED METAL ROOF SYSTEM 8. GUTTERS & DOWNSPOUTS PREFAB METAL BUILDING, SEE METAL BUILDING DWG'S 3. INSULATED METAL WALL SYSTEM STEEL DEFLECTOR PLATE, SEE STRUCTURAL FLASHING/ TRIM AT METAL PLATE BY METAL BLDG. MFR. 10. FOOTINGS & FOUNDATIONS A7.01 2 GRAVEL ACCESS AREA, SEE CIVIL DWG'S 2. MASONRY WATERTABLE, BEYOND 5. EXTERIOR SLAB (SEE CIVIL) 6. BUILDING SLAB TYPE 1 HOLLOW METAL DOOR & FRAME, PAINTED A7.01 5 B.9 Rear Cols. 1-6 2' - 0" B 7' - 0 " 10 ' - 0 " 4' - 0 " REINF. CONCRETE PUSHWALL WITH STEEL PLATE TO 4'-0" AFF, SEE STRUCTURAL SIM. Eave 36' - 0" A STEEL LINE 1. INSULATED METAL ROOF SYSTEM 8. GUTTERS & DOWNSPOUTS PREFAB METAL BUILDING, SEE METAL BUILDING DWG'S 3. INSULATED METAL WALL SYSTEM 2. MASONRY WATERTABLE 6. BUILDING SLAB TYPE 1 5. EXTERIOR SLAB (SEE CIVIL) 10. FOOTINGS & FOUNDATIONS 8" A7.03 5 A7.01 2 Rear Cols. 7-11 2' - 6" TRAFFIC RAIL AT BALE AREA SEE STRUCTURAL FOR SLAB ATTACHMENT DETAIL 9. BOLLARDS 3'-4" SE E S T R U C T U R A L VA R I E S 8' - 0 " LOUVER SIM. Eave 36' - 0" A A7.01 2 OVERHEAD ROLLING DOOR 5. EXTERIOR SLAB (SEE CIVIL) PREFAB METAL BUILDING, SEE METAL BUILDING DWG'S STEEL LINE 3. INSULATED METAL WALL SYSTEM 1. INSULATED METAL ROOF SYSTEM 6. BUILDING SLAB TYPE 1 OVERHEAD ROLLING DOOR STEEL JAMB, PAINTED 2. MASONRY WATERTABLE (BEYOND) 8. GUTTERS & DOWNSPOUTS 10. FOOTINGS & FOUNDATIONS A7.03 6 SIM. 8" Rear Cols. 7-11 2' - 6" BUILDING SYSTEMS KEYNOTES 1 MASONRY/ CONCRETE WATERTABLE:1. BRICK VENEER W/ ADJ. 2-PC. GALV. STL. ANCHORS & SPRAY-APPLIED WATER REPELLENT 2. NOMINAL 1" CAVITY (AIRSPACE) 3. 1.5" XPS RIGID FOAM BOARD INSULATING SHEATHING (R7.5) 4. REINFORCED 8" CONCRETE WALL - SEE STRUCTURAL DWG'S. 5. BASE OF CAVITY: THROUGHWALL FLASHING, MORTAR NET & OPEN HEAD JOINT WEEPS @ 24" O.C. PROVIDE OPEN HEAD JOINT INSULATED METAL ROOF SYSTEM (SEE METAL BUILDING DRAWINGS) : 1. PRE-FINISHED METAL ROOF PANELS W/ INTEGRAL SKYLIGHT PANELS (SEE ROOF PLAN, RCP PLAN, METAL BLDG. DWGS.) 2. CEE/ ZEE PURLINS 3. R-11 INSULATION (3 1/2" BATTS, 6" BATTS WITH THERMAL BLOCKS) 4. VAPOR/ WEATHER BARRIER 5. PLASTIC LINER SHEET 2 INSULATED METAL WALL SYSTEM (SEE METAL BUILDING DRAWINGS): 1. PRE-FINISHED METAL WALL PANEL 2. CEE/ ZEE GIRTS 3. R-19 INSULATION (8" BATTS) 4. VAPOR/ WEATHER BARRIER 5. PRE-FINISHED METAL WALL PANEL 3 DOCK RETAINING WALLS (SEE STRUCTURAL): 1. REINFORCED CAST-IN-PLACE CONCRETE W/ BRICK VENEER (WHERE INDICATED)4 8 11 GUTTERS & DOWNSPOUTS (SEE METAL BUILDING DRAWINGS) : 1. PRE-FINISHED ALUMINUM GUTTERS 2. PRE-FINISHED ALUMINUM DOWNSPOUTS TIED TO UNDERGROUND, SEE CIVIL OFFICE WALL: 1. BRICK VENEER W/ ADJ. 2-PC. GALV. STL. ANCHORS & SPRAY-APPLIED WATER REPELLENT 2. NOMINAL 2" CAVITY (AIRSPACE) 3. 5/8" DENSGLASS EXTERIOR SHEATHING 4. 6" METAL STUDS UP TO 28'-0" AFF AND CEE/ ZEE GIRTS 28'-0" AND ABOVE 5. R-19 INSULATION (8" BATTS) 6. VAPOR/ WEATHER BARRIER 7. 5/8" GWB, PAINTED NOT USED7 BUILDING SLAB (TYPE 1) (SEE STRUCTURAL) : 1. 10" FIBER REINFORCED CONCRETE S.O.G. W/ CONTROL JOINTS 2. 4" COMPACTED CRUSHED STONE 3. COMPACTED SUB-GRADE 5 EXTERIOR SLAB (SEE CIVIL): 1. 7" REINFORCED CONCRETE S.O.G. W/ CONTROL JOINTS 2. 7 1/2" COMPACTED CRUSHED STONE 6 12 BUILDING SLAB (TYPE 3) (SEE STRUCTURAL) : AT OFFICES 1. 4" REINFORCED CONCRETE S.O.G. W/ CONTROL JOINTS 2. VAPOR BARRIER 3. 4" COMPACTED CRUSHED STONE 4. COMPACTED SUB-GRADE 9 BOLLARDS: 1. 10" CONCRETE FILLED STEEL PIPE BOLLARD, PRIMED AND PAINTED 2. 28" DIA. 3000# CONCRETE FILLED ANCHOR BLOCK. FILL TO UNDERSIDE OF PAVEMENT 10 FOOTINGS & FOUNDATIONS (SEE STRUCTURAL): 1. REINFORCED CONCRETE FOOTINGS/ FOUNDATIONS (SEE STRUCTURAL) Scale Date 101 W. Worthington Avenue Suite 240 Charlotte, NC 28203 phone: (704) 333-3360 fax: (704) 333-3362 construction@dasarchitecture.com DAS Project Number O'Leary Resource Recovery Center 3307 Darby Avenue Charlotte, North Carolina 28216 Shell/ Core/ Upfit Package 04.14.2016 As indicated A6.52 Wall Sections - Metal Building (Rear Wall) 04/06/2016 14 205 00 1/2" = 1'-0"2 Wall Section - Retaining Wall & Sidewalk 1/2" = 1'-0"1 Wall Section - Door at Push Wall 1/2" = 1'-0"3 Wall Section - Typical at Bale Area 1/2" = 1'-0"4 Wall Section - Typical at Rear Loading Dock Doors No. Description Date 5 BD-SC.001 05/20/16 5 5 COURTESY FIELD SET Level 1 - Front 0' - 0" Eave 36' - 0" R Docks -4' - 0" A7.01 2 A7.03 4 REINFORCED CONCRETE WALL, SEE STRUCT. DWG'S OVERHEAD ROLLING DOOR 5. EXTERIOR SLAB (SEE CIVIL) STEEL LINE 3. INSULATED METAL WALL SYSTEM 1. INSULATED METAL ROOF SYSTEM 6. BUILDING SLAB TYPE 1 OVERHEAD ROLLING DOOR STEEL JAMB, PAINTED 8. GUTTERS & DOWNSPOUTS 10. FOOTINGS & FOUNDATIONS DOCK BUMPERS TRENCH DRAIN,SEE CIVIL .A7.53 2 Sim OVERHEAD ROLLING DOOR TRUCK SEAL FLASHING BY PREFAB METAL BUILDING MFR. SIM. DOCK LEVELER 5'- 0 " . 1' - 0 " Level 1 - Front 0' - 0" Eave 36' - 0" R Docks -4' - 0" A7.01 2 A7.03 2 REINFORCED CONCRETE WALL, SEE STRUCT. DWG'S 5. EXTERIOR SLAB (SEE CIVIL) STEEL LINE 3. INSULATED METAL WALL SYSTEM 1. INSULATED METAL ROOF SYSTEM 6. BUILDING SLAB TYPE 1 2. MASONRY WATERTABLE 8. GUTTERS & DOWNSPOUTS 10. FOOTINGS & FOUNDATIONS DOCK BUMPERS TRENCH DRAIN, SEE CIVIL OVERHEAD ROLLING DOOR TRUCK SEAL FLASHING BY PREFAB METAL BUILDING MFR. SIM. 5'- 0 " 1'- 0 " LOUVER Eave 36' - 0" A 8" 2. MASONRY WATERTABLE STEEL LINE 9. BOLLARDS 5. EXTERIOR SLAB (SEE CIVIL) PREFAB METAL BUILDING, SEE METAL BUILDING DWG'S 3. INSULATED METAL WALL SYSTEM 1. INSULATED METAL ROOF SYSTEM 6. BUILDING SLAB TYPE 1 8. GUTTERS & DOWNSPOUTS 10. FOOTINGS & FOUNDATIONS A7.04 1 Rear Cols. 7-11 2' - 6" SIM. A7.01 2 Level 1 - Front 0' - 0" Eave 36' - 0" R A7.04 6 A7.01 2 5. EXTERIOR SLAB (SEE CIVIL) 2. MASONRY WATERTABLE PREFAB METAL BUILDING, BEYOND SEE METAL BUILDING DWG'S STEEL LINE 3. INSULATED METAL WALL SYSTEM 1. INSULATED METAL ROOF SYSTEM 8. GUTTERS & DOWNSPOUTS 6. BUILDING SLAB TYPE 1 10. FOOTINGS & FOUNDATIONS A7.51 5 BUILDING SYSTEMS KEYNOTES 1 MASONRY/ CONCRETE WATERTABLE: 1. BRICK VENEER W/ ADJ. 2-PC. GALV. STL. ANCHORS & SPRAY-APPLIED WATER REPELLENT 2. NOMINAL 1" CAVITY (AIRSPACE)3. 1.5" XPS RIGID FOAM BOARD INSULATING SHEATHING (R7.5) 4. REINFORCED 8" CONCRETE WALL - SEE STRUCTURAL DWG'S. 5. BASE OF CAVITY: THROUGHWALL FLASHING, MORTAR NET & OPEN HEAD JOINT WEEPS @ 24" O.C. PROVIDE OPEN HEAD JOINT INSULATED METAL ROOF SYSTEM (SEE METAL BUILDING DRAWINGS) : 1. PRE-FINISHED METAL ROOF PANELS W/ INTEGRAL SKYLIGHT PANELS (SEE ROOF PLAN, RCP PLAN, METAL BLDG. DWGS.) 2. CEE/ ZEE PURLINS 3. R-11 INSULATION (3 1/2" BATTS, 6" BATTS WITH THERMAL BLOCKS) 4. VAPOR/ WEATHER BARRIER 5. PLASTIC LINER SHEET 2 INSULATED METAL WALL SYSTEM (SEE METAL BUILDING DRAWINGS): 1. PRE-FINISHED METAL WALL PANEL 2. CEE/ ZEE GIRTS 3. R-19 INSULATION (8" BATTS) 4. VAPOR/ WEATHER BARRIER 5. PRE-FINISHED METAL WALL PANEL 3 DOCK RETAINING WALLS (SEE STRUCTURAL): 1. REINFORCED CAST-IN-PLACE CONCRETE W/ BRICK VENEER (WHERE INDICATED)4 8 11 GUTTERS & DOWNSPOUTS (SEE METAL BUILDING DRAWINGS) : 1. PRE-FINISHED ALUMINUM GUTTERS 2. PRE-FINISHED ALUMINUM DOWNSPOUTS TIED TO UNDERGROUND, SEE CIVIL OFFICE WALL: 1. BRICK VENEER W/ ADJ. 2-PC. GALV. STL. ANCHORS & SPRAY-APPLIED WATER REPELLENT 2. NOMINAL 2" CAVITY (AIRSPACE) 3. 5/8" DENSGLASS EXTERIOR SHEATHING 4. 6" METAL STUDS UP TO 28'-0" AFF AND CEE/ ZEE GIRTS 28'-0" AND ABOVE 5. R-19 INSULATION (8" BATTS)6. VAPOR/ WEATHER BARRIER 7. 5/8" GWB, PAINTED NOT USED7 BUILDING SLAB (TYPE 1) (SEE STRUCTURAL) : 1. 10" FIBER REINFORCED CONCRETE S.O.G. W/ CONTROL JOINTS 2. 4" COMPACTED CRUSHED STONE 3. COMPACTED SUB-GRADE 5 EXTERIOR SLAB (SEE CIVIL):1. 7" REINFORCED CONCRETE S.O.G. W/ CONTROL JOINTS 2. 7 1/2" COMPACTED CRUSHED STONE 6 12 BUILDING SLAB (TYPE 3) (SEE STRUCTURAL) : AT OFFICES 1. 4" REINFORCED CONCRETE S.O.G. W/ CONTROL JOINTS 2. VAPOR BARRIER 3. 4" COMPACTED CRUSHED STONE 4. COMPACTED SUB-GRADE 9 BOLLARDS: 1. 10" CONCRETE FILLED STEEL PIPE BOLLARD, PRIMED AND PAINTED2. 28" DIA. 3000# CONCRETE FILLED ANCHOR BLOCK. FILL TO UNDERSIDE OF PAVEMENT 10 FOOTINGS & FOUNDATIONS (SEE STRUCTURAL): 1. REINFORCED CONCRETE FOOTINGS/ FOUNDATIONS (SEE STRUCTURAL) Scale Date 101 W. Worthington Avenue Suite 240 Charlotte, NC 28203 phone: (704) 333-3360 fax: (704) 333-3362 construction@dasarchitecture.com DAS Project Number O'Leary Resource Recovery Center 3307 Darby Avenue Charlotte, North Carolina 28216 Shell/ Core/ Upfit Package 04.14.2016 As indicated A6.53 Wall Sections - Metal Building/ Loading Docks 04/06/2016 14 205 00 1/2" = 1'-0"1 Wall Section - Typical at Front Loading Dock Doors 1/2" = 1'-0"2 Wall Section - Typical at Front Loading Docks 1/2" = 1'-0"4 Wall Section - Typical at Rear Loading Docks 1/2" = 1'-0"5 Wall Section - Typical at Front Wall Perimeter No. Description Date 5 BD-SC.001 05/20/16 5 5 COURTESY FIELD SET Eave 36' - 0" 6 7 STEEL LINE 1. INSULATED METAL ROOF SYSTEM PREFAB METAL BUILDING, SEE METAL BUILDING DWG'S 3. INSULATED METAL WALL SYSTEM 2. MASONRY WATERTABLE 6. BUILDING SLAB TYPE 1 5. EXTERIOR SLAB (SEE CIVIL) 8" 1'-4" .A7.52 2 Sim A7.03 5 GRAVEL ACCESS AREA, SEE CIVIL DWG'S Rear Cols. 7-11 2' - 6" TRAFFIC RAIL FOR BALE AREA 10. FOOTINGS AND FOUNDATIONS 5'-0" SIM. VA R I E S Eave 36' - 0" 1 5. EXTERIOR SLAB (SEE CIVIL) 10. FOOTINGS AND FOUNDATIONS STEEL LINE 1. INSULATED METAL ROOF SYSTEM PREFAB METAL BUILDING, SEE METAL BUILDING DWG'S 3. INSULATED METAL WALL SYSTEM 2. MASONRY WATERTABLE 10'-0" H. X 12" WIDE REINF. CONCRETE WALL WITH PLATE STEEL STEEL DEFLECTOR PLATE, SEE STRUCTURAL FLASHING/ TRIM AT METAL PLATE BY METAL BLDG. MFR. 8" 6. BUILDING SLAB TYPE 1 .A7.52 2 Sim A7.01 3 Rear Cols. 1-6 2' - 0" Rear Cols. 7-11 2' - 6" 7' - 0 " 10 ' - 0 " 4'- 0 " Eave 36' - 0" 1 2 A6.02 GRADE, SEE CIVIL 10. FOOTINGS AND FOUNDATIONS 8" 12" TH. REINF. CONCRETE WALL SEE STRUCTURAL DWGS. METAL BUILDING END FRAMING 2. MASONRY WATERTABLE 3/8" PLATE PYRAMID, SEE STRUCTURAL 10" REINFORCED CONCRETE SLAB OVER 8" COMPACTED STONE. SEE STRUCT. DWG'S STEEL LINE 1. INSULATED METAL ROOF SYSTEM PREFAB METAL BUILDING, SEE METAL BUILDING DWG'S 3. INSULATED METAL WALL SYSTEM .A7.52 2 Sim 1'-8" Rear Cols. 1-6 2' - 0" 15'-0" 8" 3'-0" 8" TH. WIDE REINF. CONC. WALL, SEE STRUCTURAL 2' - 0 " STEEL DEFLECTOR PLATE 1'-0" 3'- 0 " A7.01 6 Level 1 - Front 0' - 0" Eave 36' - 0" 11 Level 2 14' - 0" 12 A7.04 2 5. EXTERIOR SLAB (SEE CIVIL) 2. MASONRY WATERTABLE BEYOND 42" H. GUARDRAIL ON CATWALK STRUCTURE STEEL LINE 3. INSULATED METAL WALL SYSTEM 1. INSULATED METAL ROOF SYSTEM 8. GUTTERS & DOWNSPOUTS, BEYOND 6. BUILDING SLAB TYPE 1 9. BOLLARD 10. FOOTINGS AND FOUNDATIONS A7.02 6 Level 1 - Offices 1' - 6" 2 A6.03 VA R I E S 1'- 0 " 2'-10" 1 1/2" O.D. PIPE HANDRAIL, PAINTED 3'-6" TRAFFIC RAIL HSS POSTS, PAINTED 6. BUILDING SLAB TYPE 1 BUILDING SYSTEMS KEYNOTES 1 MASONRY/ CONCRETE WATERTABLE: 1. BRICK VENEER W/ ADJ. 2-PC. GALV. STL. ANCHORS & SPRAY-APPLIED WATER REPELLENT 2. NOMINAL 1" CAVITY (AIRSPACE) 3. 1.5" XPS RIGID FOAM BOARD INSULATING SHEATHING (R7.5) 4. REINFORCED 8" CONCRETE WALL - SEE STRUCTURAL DWG'S. 5. BASE OF CAVITY: THROUGHWALL FLASHING, MORTAR NET & OPEN HEAD JOINT WEEPS @ 24" O.C. PROVIDE OPEN HEAD JOINT INSULATED METAL ROOF SYSTEM (SEE METAL BUILDING DRAWINGS) : 1. PRE-FINISHED METAL ROOF PANELS W/ INTEGRAL SKYLIGHT PANELS (SEE ROOF PLAN, RCP PLAN, METAL BLDG. DWGS.) 2. CEE/ ZEE PURLINS 3. R-11 INSULATION (3 1/2" BATTS, 6" BATTS WITH THERMAL BLOCKS) 4. VAPOR/ WEATHER BARRIER 5. PLASTIC LINER SHEET 2 INSULATED METAL WALL SYSTEM (SEE METAL BUILDING DRAWINGS): 1. PRE-FINISHED METAL WALL PANEL 2. CEE/ ZEE GIRTS 3. R-19 INSULATION (8" BATTS) 4. VAPOR/ WEATHER BARRIER 5. PRE-FINISHED METAL WALL PANEL 3 DOCK RETAINING WALLS (SEE STRUCTURAL): 1. REINFORCED CAST-IN-PLACE CONCRETE W/ BRICK VENEER (WHERE INDICATED)4 8 11 GUTTERS & DOWNSPOUTS (SEE METAL BUILDING DRAWINGS) : 1. PRE-FINISHED ALUMINUM GUTTERS 2. PRE-FINISHED ALUMINUM DOWNSPOUTS TIED TO UNDERGROUND, SEE CIVIL OFFICE WALL: 1. BRICK VENEER W/ ADJ. 2-PC. GALV. STL. ANCHORS & SPRAY-APPLIED WATER REPELLENT 2. NOMINAL 2" CAVITY (AIRSPACE) 3. 5/8" DENSGLASS EXTERIOR SHEATHING 4. 6" METAL STUDS UP TO 28'-0" AFF AND CEE/ ZEE GIRTS 28'-0" AND ABOVE 5. R-19 INSULATION (8" BATTS) 6. VAPOR/ WEATHER BARRIER 7. 5/8" GWB, PAINTED NOT USED7 BUILDING SLAB (TYPE 1) (SEE STRUCTURAL) : 1. 10" FIBER REINFORCED CONCRETE S.O.G. W/ CONTROL JOINTS 2. 4" COMPACTED CRUSHED STONE 3. COMPACTED SUB-GRADE 5 EXTERIOR SLAB (SEE CIVIL): 1. 7" REINFORCED CONCRETE S.O.G. W/ CONTROL JOINTS 2. 7 1/2" COMPACTED CRUSHED STONE 6 12 BUILDING SLAB (TYPE 3) (SEE STRUCTURAL) : AT OFFICES 1. 4" REINFORCED CONCRETE S.O.G. W/ CONTROL JOINTS 2. VAPOR BARRIER 3. 4" COMPACTED CRUSHED STONE 4. COMPACTED SUB-GRADE 9 BOLLARDS: 1. 10" CONCRETE FILLED STEEL PIPE BOLLARD, PRIMED AND PAINTED 2. 28" DIA. 3000# CONCRETE FILLED ANCHOR BLOCK. FILL TO UNDERSIDE OF PAVEMENT 10 FOOTINGS & FOUNDATIONS (SEE STRUCTURAL): 1. REINFORCED CONCRETE FOOTINGS/ FOUNDATIONS (SEE STRUCTURAL) Scale Date 101 W. Worthington Avenue Suite 240 Charlotte, NC 28203 phone: (704) 333-3360 fax: (704) 333-3362 construction@dasarchitecture.com DAS Project Number O'Leary Resource Recovery Center 3307 Darby Avenue Charlotte, North Carolina 28216 Shell/ Core/ Upfit Package 04.14.2016 As indicated A6.54 Wall Sections - Metal Building 04/06/2016 14 205 00 1/2" = 1'-0"2 Wall Section - Typical at Metal Building Rear End Wall 1/2" = 1'-0"1 Wall Section - Typical at Metal Building End Wall 3/8" = 1'-0"3 Wall Section - Building End Wall at Transfer Bay 1/2" = 1'-0"4 Wall Section - Typical at Side Wall No. Description Date 5 BD-SC.001 05/20/16 5 5 COURTESY FIELD SET 6 7 6. BUILDING SLAB TYPE 1 A7.03 5 SIM. 2. MASONRY WATERTABLE 3. INSULATED METAL WALL SYSTEM 10. FOOTINGS AND FOUNDATIONS CONCRETE/ COMPOSITE DECK, SEE STRUCTURAL DWG'S. REINF. CONCRETE WALL Rear Cols. 1-6 2' - 0" Rear Cols. 7-11 2' - 6" 10 ' - 0 " TRAFFIC RAIL AT BALE AREA 5. EXTERIOR SLAB (SEE CIVIL) 9. BOLLARDS 8'- 0 " Level 1 - Front 0' - 0" 10 111 A6.53 2 A6.53 Docks -4' - 0" 1 A6.02 4'- 0 " 8" A112 A111 A110 1'-0"28'-7 1/2"1'-4" 2'-6"10'-0"3'-4"10'-0"2'-9 1/2" REINF. CONCRETE SLAB, SEE CIVIL 5. EXTERIOR SLAB (SEE CIVIL) HOLLOW METAL DOOR W/ TRANSOM, PAINTED 2. MASONRY WATERTABLE BEYOND 12" WIDE REINF. CONCRETE WALL, SEE CIVIL 8. GUTTERS & DOWNSPOUTS GRADE, SEE CIVIL REINF. CONCRETE WALL, SEE CIVIL OVERHEAD ROLLING DOOR BRICK VENEER ON REINF. CONC. RETAINING WALL DOCK BUMPERS CONCRETE WALL TO EXTENDS TO GRADE IN LOADING DOCK BAY 4'- 4 " OVERHEAD ROLLING DOOR TRUCK SEAL 6"10" BRICK BEYOND (DASHED) 1'-0" 12 Level 1 - Offices 1' - 6" 2 A6.03 1'-4" A7.04 7 A7.04 8 Eave 36' - 0" 11 5. EXTERIOR SLAB (SEE CIVIL) 2. MASONRY WATERTABLE STEEL LINE 3. INSULATED METAL WALL SYSTEM 1. INSULATED METAL ROOF SYSTEM 6. BUILDING SLAB TYPE 1 9. BOLLARDS OVERHEAD ROLLING DOOR, BEYOND .A7.52 2 Sim A7.04 1 Rear Cols. 7-11 2' - 6" SE E S T R U C T U R A L VA R I E S 1' - 1 " 10. FOOTINGS & FOUNDATIONS BUILDING SYSTEMS KEYNOTES 1 MASONRY/ CONCRETE WATERTABLE: 1. BRICK VENEER W/ ADJ. 2-PC. GALV. STL. ANCHORS & SPRAY-APPLIED WATER REPELLENT 2. NOMINAL 1" CAVITY (AIRSPACE) 3. 1.5" XPS RIGID FOAM BOARD INSULATING SHEATHING (R7.5) 4. REINFORCED 8" CONCRETE WALL - SEE STRUCTURAL DWG'S. 5. BASE OF CAVITY: THROUGHWALL FLASHING, MORTAR NET & OPEN HEAD JOINT WEEPS @ 24" O.C. PROVIDE OPEN HEAD JOINT INSULATED METAL ROOF SYSTEM (SEE METAL BUILDING DRAWINGS) : 1. PRE-FINISHED METAL ROOF PANELS W/ INTEGRAL SKYLIGHT PANELS (SEE ROOF PLAN, RCP PLAN, METAL BLDG. DWGS.) 2. CEE/ ZEE PURLINS 3. R-11 INSULATION (3 1/2" BATTS, 6" BATTS WITH THERMAL BLOCKS) 4. VAPOR/ WEATHER BARRIER 5. PLASTIC LINER SHEET 2 INSULATED METAL WALL SYSTEM (SEE METAL BUILDING DRAWINGS): 1. PRE-FINISHED METAL WALL PANEL 2. CEE/ ZEE GIRTS 3. R-19 INSULATION (8" BATTS) 4. VAPOR/ WEATHER BARRIER 5. PRE-FINISHED METAL WALL PANEL 3 DOCK RETAINING WALLS (SEE STRUCTURAL): 1. REINFORCED CAST-IN-PLACE CONCRETE W/ BRICK VENEER (WHERE INDICATED)4 8 11 GUTTERS & DOWNSPOUTS (SEE METAL BUILDING DRAWINGS) : 1. PRE-FINISHED ALUMINUM GUTTERS2. PRE-FINISHED ALUMINUM DOWNSPOUTS TIED TO UNDERGROUND, SEE CIVIL OFFICE WALL: 1. BRICK VENEER W/ ADJ. 2-PC. GALV. STL. ANCHORS & SPRAY-APPLIED WATER REPELLENT 2. NOMINAL 2" CAVITY (AIRSPACE) 3. 5/8" DENSGLASS EXTERIOR SHEATHING 4. 6" METAL STUDS UP TO 28'-0" AFF AND CEE/ ZEE GIRTS 28'-0" AND ABOVE 5. R-19 INSULATION (8" BATTS) 6. VAPOR/ WEATHER BARRIER 7. 5/8" GWB, PAINTED NOT USED7 BUILDING SLAB (TYPE 1) (SEE STRUCTURAL) : 1. 10" FIBER REINFORCED CONCRETE S.O.G. W/ CONTROL JOINTS 2. 4" COMPACTED CRUSHED STONE 3. COMPACTED SUB-GRADE 5 EXTERIOR SLAB (SEE CIVIL): 1. 7" REINFORCED CONCRETE S.O.G. W/ CONTROL JOINTS 2. 7 1/2" COMPACTED CRUSHED STONE 6 12 BUILDING SLAB (TYPE 3) (SEE STRUCTURAL) : AT OFFICES 1. 4" REINFORCED CONCRETE S.O.G. W/ CONTROL JOINTS 2. VAPOR BARRIER 3. 4" COMPACTED CRUSHED STONE 4. COMPACTED SUB-GRADE 9 BOLLARDS: 1. 10" CONCRETE FILLED STEEL PIPE BOLLARD, PRIMED AND PAINTED 2. 28" DIA. 3000# CONCRETE FILLED ANCHOR BLOCK. FILL TO UNDERSIDE OF PAVEMENT 10 FOOTINGS & FOUNDATIONS (SEE STRUCTURAL): 1. REINFORCED CONCRETE FOOTINGS/ FOUNDATIONS (SEE STRUCTURAL) UNDERSIDE OF STRUCTURE 8" TH. REINF. CONCRETE WALL, SEE STRUCTURAL 8" 1/2" 5/8" UNFINISHED FLOOR CONT. SEALANT 8" PRE-MANUFACTUREDD METAL BUILDING GIRTS R-13 8" INSULATION BATTS 1 LAYER 5/8" GWB FINISH AS SCHEDULED SCHEDULED BASE (OFFICES) 1/2" METAL FURRING 1 LAYER 5/8" GWB EACH SIDE, FINISH AS SCHEDULED R-13 8" INSULATION BATTS 8" METAL STUDS @ 16" O.C. 25 GA. MIN. DESIGN BUILD BY CONTRACTOR SCHEDULED CEILING(S) 1 1/4" METAL BUILDING PANEL DASHED 1 1/4"5/8"8" 5/8" 4'- 4 " A F F 4" . 1 1/4" METAL BUILDING PANEL DASHED 28 ' - 0 " A F F 8" M E T A L S T U D F R A M I N G 8" M E T A L B U I L D I N G G I R T S Eave 36' - 0" 11 Level 2 14' - 0" 12 Rear Cols. 1-6 2' - 0" 5. EXTERIOR SLAB (SEE CIVIL) 2. MASONRY WATERTABLE STEEL LINE 3. INSULATED METAL WALL SYSTEM 1. INSULATED METAL ROOF SYSTEM 6. BUILDING SLAB TYPE 1 9. BOLLARDS SE E S T R U C T U R A L VA R I E S 1' - 1 " 10. FOOTINGS & FOUNDATIONS LIGHT SCONCE, SEE ELECTRICAL PREFINISHED METAL CANOPY PREFINISHED METAL TIE RODS METAL BUILDING STRUCTURE ALUMINUM STOREFRONT ALUMINUM STOREFRONT 4' - 8 " 7' - 4 " 2' - 1 1 " 2' - 6 " 10 ' - 0 " . MEZZANINE GIRDER INFILLED WITH 3 5/8" METAL STUDS & WRAPPED WITH METAL TO MATCH EXTERIOR EYEBROW CANOPIES 1'-2" Scale Date 101 W. Worthington Avenue Suite 240 Charlotte, NC 28203 phone: (704) 333-3360 fax: (704) 333-3362 construction@dasarchitecture.com DAS Project Number O'Leary Resource Recovery Center 3307 Darby Avenue Charlotte, North Carolina 28216 Shell/ Core/ Upfit Package 04.14.2016 As indicated A6.55 Wall Sections 04/06/2016 14 205 00 1/2" = 1'-0"2 Wall Section - Electrical Room 1/2" = 1'-0"1 Wall Section - Retaining Walls at Docks 1/2" = 1'-0"4 Wall Section - Typical at Building Ends No. Description Date 5 BD-SC.001 05/20/16 1" = 1'-0"55 Wall Section - Wall Between Office and Factory 1/2" = 1'-0"5 Wall Section - Building Entrance 5 5 COURTESY FIELD SET Level 1 - Front 0' - 0" D H MEGJ3 A6.56 10 " 6'- 2 " 1'-0" 4'-5"50'-0"11'-11" 1'-0" 10 " 6'- 2 " 10" TH. REINFORCED CONCRETE SLAB, SEE STRUCTURAL 12" TH. REINFORCED CONCRETE WALL, SEE STRUCTURAL 12" TH. REINFORCED CONCRETE SLAB, SEE STRUCTURAL SEE PLUMBING DRAWINGS FOR SUMP PIT, INSTALLED PER MANUFACTURER'S RECOMENDATIONS 12" TH. REINFORCED CONCRETE WALL, SEE STRUCTURAL 66'-4" 10" TH. REINFORCED CONCRETE BASE SLAB, SEE STRUCTURAL METAL PIT COVERS BY EQUIPMENT MFR. 24" WIDE LADDER Conveyor Pits -7' - 0" A7.51 6 Sim A7.51 6 Sim FOUNDATION DRAIN, SEE STRUCTURAL10 " 4'- 0 " 7'- 0 " SLOPE SLOPE 5 A6.55 SLOPE 10"5'-0"10" 24x24 AREA DRAIN WITH PERFORATED COVER Level 1 - Front 0' - 0" M 10" TH. REINFORCED CONCRETE SLAB, SEE STRUCTURAL 12" TH., REINFORCED CONCRETE WALL, SEE STRUCTURAL 12" TH. REINFORCED CONCRETE SLAB SEE STRUCTURAL35'-7" 10 " 16'-3 1/2" 1'-0" METAL PIT COVERS BY EQUIPMENT MFR. 24" WIDE LADDER Conveyor Pits -7' - 0" 1'-0" 19'-3 1/2" A7.51 6 Sim 1' - 0 " 6' - 0 " 24" X 24" AREA DRAIN WITH PERFORATED COVER FOUNDATION DRAIN, SEE STRUCTURAL 10 " 4' - 0 " 7 ' - 0 " SLOPE SLOPE SEE PLUMBING DRAWINGS FOR SUMP PIT, INSTALLED PER MANUFACTURER'S RECOMENDATIONS 10"5'-0"10" 10. FOOTINGS & FOUNDATIONS Level 1 - Front 0' - 0" 9 1'-0" 10'-0" 1'-0" 10" TH. REINFORCED CONCRETE SLAB, SEE STRUCTURAL 12" TH. REINFORCED CONCRETE WALL, SEE STRUCTURAL 12" TH. REINFORCED CONCRETE SLAB, SEE STRUCTURAL METAL PIT COVERS BY EQUIPMENT MFR. Conveyor Pits -7' - 0" 1' - 0 " 6' - 0 " A7.51 6 Sim A7.51 6 Sim 10. FOOTINGS & FOUNDATIONS FOUNDATION DRAIN, SEE STRUCTURAL SEE PLUMBING DRAWINGS FOR SUMP PIT, INSTALLED PER MANUFACTURER'S RECOMENDATIONS BUILDING SYSTEMS KEYNOTES 1 MASONRY/ CONCRETE WATERTABLE: 1. BRICK VENEER W/ ADJ. 2-PC. GALV. STL. ANCHORS & SPRAY-APPLIED WATER REPELLENT 2. NOMINAL 1" CAVITY (AIRSPACE) 3. 1.5" XPS RIGID FOAM BOARD INSULATING SHEATHING (R7.5) 4. REINFORCED 8" CONCRETE WALL - SEE STRUCTURAL DWG'S. 5. BASE OF CAVITY: THROUGHWALL FLASHING, MORTAR NET & OPEN HEAD JOINT WEEPS @ 24" O.C. PROVIDE OPEN HEAD JOINT INSULATED METAL ROOF SYSTEM (SEE METAL BUILDING DRAWINGS) : 1. PRE-FINISHED METAL ROOF PANELS W/ INTEGRAL SKYLIGHT PANELS (SEE ROOF PLAN, RCP PLAN, METAL BLDG. DWGS.) 2. CEE/ ZEE PURLINS 3. R-11 INSULATION (3 1/2" BATTS, 6" BATTS WITH THERMAL BLOCKS) 4. VAPOR/ WEATHER BARRIER 5. PLASTIC LINER SHEET 2 INSULATED METAL WALL SYSTEM (SEE METAL BUILDING DRAWINGS): 1. PRE-FINISHED METAL WALL PANEL 2. CEE/ ZEE GIRTS 3. R-19 INSULATION (8" BATTS) 4. VAPOR/ WEATHER BARRIER 5. PRE-FINISHED METAL WALL PANEL 3 DOCK RETAINING WALLS (SEE STRUCTURAL): 1. REINFORCED CAST-IN-PLACE CONCRETE W/ BRICK VENEER (WHERE INDICATED)4 8 11 GUTTERS & DOWNSPOUTS (SEE METAL BUILDING DRAWINGS) : 1. PRE-FINISHED ALUMINUM GUTTERS 2. PRE-FINISHED ALUMINUM DOWNSPOUTS TIED TO UNDERGROUND, SEE CIVIL OFFICE WALL: 1. BRICK VENEER W/ ADJ. 2-PC. GALV. STL. ANCHORS & SPRAY-APPLIED WATER REPELLENT 2. NOMINAL 2" CAVITY (AIRSPACE) 3. 5/8" DENSGLASS EXTERIOR SHEATHING 4. 6" METAL STUDS UP TO 28'-0" AFF AND CEE/ ZEE GIRTS 28'-0" AND ABOVE 5. R-19 INSULATION (8" BATTS) 6. VAPOR/ WEATHER BARRIER 7. 5/8" GWB, PAINTED NOT USED7 BUILDING SLAB (TYPE 1) (SEE STRUCTURAL) : 1. 10" FIBER REINFORCED CONCRETE S.O.G. W/ CONTROL JOINTS 2. 4" COMPACTED CRUSHED STONE 3. COMPACTED SUB-GRADE 5 EXTERIOR SLAB (SEE CIVIL): 1. 7" REINFORCED CONCRETE S.O.G. W/ CONTROL JOINTS 2. 7 1/2" COMPACTED CRUSHED STONE 6 12 BUILDING SLAB (TYPE 3) (SEE STRUCTURAL) : AT OFFICES 1. 4" REINFORCED CONCRETE S.O.G. W/ CONTROL JOINTS 2. VAPOR BARRIER 3. 4" COMPACTED CRUSHED STONE 4. COMPACTED SUB-GRADE 9 BOLLARDS: 1. 10" CONCRETE FILLED STEEL PIPE BOLLARD, PRIMED AND PAINTED 2. 28" DIA. 3000# CONCRETE FILLED ANCHOR BLOCK. FILL TO UNDERSIDE OF PAVEMENT 10 FOOTINGS & FOUNDATIONS (SEE STRUCTURAL): 1. REINFORCED CONCRETE FOOTINGS/ FOUNDATIONS (SEE STRUCTURAL) Scale Date 101 W. Worthington Avenue Suite 240 Charlotte, NC 28203 phone: (704) 333-3360 fax: (704) 333-3362 construction@dasarchitecture.com DAS Project Number O'Leary Resource Recovery Center 3307 Darby Avenue Charlotte, North Carolina 28216 Shell/ Core/ Upfit Package 04.14.2016 As indicated A6.56 Wall Sections - Conveyor Pits 04/06/2016 14 205 00 1/2" = 1'-0"1 Section Detail - Pit 1A 1/2" = 1'-0"2 Section Detail - Pit 2A 1/2" = 1'-0"3 Section Detail - General Pit Detail NOTE: FINAL PIT CONFIGURATION AND LOCATION SHALL BE VERIFIED WITH OWNER AND EQUIPMENT MANUFACTURER PRIOR TO INSTALL NOTE: FINAL PIT CONFIGURATION AND LOCATION SHALL BE VERIFIED WITH OWNER AND EQUIPMENT MANUFACTURER PRIOR TO INSTALL NOTE: FINAL PIT CONFIGURATION AND LOCATION SHALL BE VERIFIED WITH OWNER AND EQUIPMENT MANUFACTURER PRIOR TO INSTALL No. Description Date 5 BD-SC.001 05/20/16 5 5 5 5 5 COURTESY FIELD SET FLOW BP BP 02-0970 FLOW BP BP 02-0970 PARTITION LEGEND METAL GIRTS/ METAL STUDS CONFIGURATION VARIES 1-HR FIRE BARRIER CONFIGURATION VARIES 2-HR FIRE BARRIER CONFIGURATION VARIES STOREFRONT / WINDOW CONFIGURATION VARIES N.T.S. CMU/ CONCRETE CONFIGURATION VARIES OVERALL PLAN NOTES 1. CONTROL LINE/ FACE OF BUILDING = FACE OF METAL BUILDING CEE/ ZEE GIRTS, FACE OF CMU, FACE OF CONCRETE 2. NOT USED 3. SEE STRUCTURAL DRAWINGS FOR LOCATIONS OF SLAB ON GRADE CONTROL JOINTS AND CONSTRUCTION JOINTS 4. STEEL PIPE BOLLARDS OR CONCRETE IMPACT WALLS REQUIRED AT ALL METAL BUILDING STRUCTURAL ELEMENTS, PLUMBING & ELECTRICAL VERTICAL STACKS 5. SEE STRUCTURAL DRAWINGS FOR CONCRETE RETAINING WALLS 6. FINAL LOCATION OF CONVEYOR PITS SHOULD BE DETERMINED IN THE FIELD BASED ON PACEMENT OF CONVEYOR EQUIPMENT. 7. CATWALK/ STAIR SYSTEM PART OF SORTING EQUIPMENT SHALL COMPLY WITH NCSBC AND OSHA 8. SEE METCAL BUILDING DRAWINGS FOR ADDITIONAL INFORMATION ON PRE-FABRICATED METAL BUILDING DS DOWNSPOUT FD FLOOR DRAIN A5.011 A5.02 1 A5.01 2 2 2 3 3 4 4 5 5 8 8 9 9 10 10 11 11 RR 1 1 2 A6.02 A5.02 2 AA 2 A6.01 1 A6.51 4 A6.51 3 A6.51 3 A6.54 1 A6.54 1 A6.53 2 A6.51 2 A6.53 2 A6.54 4 A6.52 4 A6.53 1 A6.55 1 A6.01 3 A6.03 3 A6.02 1 A6.02 2 A6.52 1 A6.03 1 A6.57 2 A6.57 WOMENS TOILET OFFICE 2 MENS TOILET RECEPTION / OFFICE 1 TIPPING FLOOR 113 BALE AREA 115 LOADING DOCKS 110 LOADING BAYS 116 A112 A110 A117 A111 A116 A114 A108 A113 A106 A124 A126A125 A118 A115 A105 A122 1 A6.58 24 ' - 6 " 70 ' - 2 " 26 ' - 8 " 29'-0"28'-2"28'-2"28'-2"26'-10"30'-4"27'-8"27'-8"29'-0" 140'-4"114'-8" 23 ' - 0 " 25 ' - 0 " 25 ' - 0 " 25 ' - 0 " 23 ' - 4 " 35 ' - 0 " D H M M Q 6 6 29'-0"28'-2"28'-2"28'-2"28'-2"29'-0"27'-8"27'-8"29'-0" 140'-4"114'-8" 15 6 ' - 4 " 20 ' - 0 " 69'-1" 1'-4" 3'-4" BRACING BRACING BRACING BRACING 7 7 C 26 ' - 0 " 20 ' - 0 " 19 ' - 4 " 1 2 ' - 1 0 " 1 2 ' - 1 0 " 2 2 ' - 6 " 7 ' - 1 0 " 3 5 ' - 0 " E G J N P 14'-6" 14'-1"14'-1"14'-3"13'-11"14'-1"14'-1"14'-1"14'-1"14'-6"14'-6" 7'-4"13'-4"8'-4" A119 1 A6.52 3 A6.52 A101 A109a A4.01 4 A4.01 3 12 12 13 13 14 14 B.9 P.1 ELECTRICAL 114A123 2 A6.55 5 A6.53 BR A C I N G BR A C I N G 75 ' - 0 " 13'-9"14'-7" STAIRS A104 255'-0" DISPATCH / SCALEMASTER / OFFICE 3 TELE./ ELEC. JAN. A107 A120 A121 A102 A103 A109b 2 A6.03 10' HIGH 12" TH.REINF. CONC. PUSH WALLS W/ STEEL PLATE UP TO 24" AFF 3' HIGH 12" TH. REINF. CONC. WALL 10' HIGH 12" TH. REINF. CONC. PUSH WALLS W/ STEEL PLATE UP TO 48" AFF AND STEEL DEFLECTOR PLATES 4' HIGH 8" TH. REINF. CONCRETE WALL FLOOR DRAINS TYP. OF 2 SL O P E 2 ' - 0 " (7 3 9 . 0 0 T O 7 4 1 . 0 0 ) JERSEY BLOCK WALL BY OWNER 4'-4" HIGH 16" TH. REINF. CONC. WALLS, TYPICAL OF 7 12" REINFORCED CONC. ISOLATED SLAB AT BAILER, SEE STRUCTURAL 18" WIDE TRAFFIC RATED TRENCH DRAIN MHD-18 WITH GALV. GRATE AT 738.75 64"L x 74"W x 20"D DOCK LEVELERS, TYPICAL OF 2 2'X18' WIDE CONC. WATER DEFLECTORS AT OVERHEAD DOORS, TYPICAL OF 5 9'- 0 " JERSEY BLOCK WALL, BY OWNER SL O P E 2 ' - 0 " (7 3 9 . 0 0 T O 7 4 1 . 0 0 ) SL O P E 2 ' - 6 " (7 3 9 . 0 0 T O 7 4 1 . 5 0 ) CONVEYOR PIT 12" TH. REINF. CONC. WALLS 36' X 10' X 7' DEEP CONVEYOR PIT- 12" TH. REINF. CONC. WALLS 66'-8" X 10' X 7' DEEP GRAVEL ACCESS AREA FLOOR DRAINS TYP. OF 2 SLOPE FLOOR TO DRAIN 10" TH. CONCRETE S.O.G OVER COMPACTED STONE, OVER COMPACTED SUB-GRADE. SEE STRUCTURAL SPECIFICATION FOR CONC. MIX DESIGN, REINFORCING, JOINTS, ETC. SCUPPER 12X12X36 SEE STRUCTURAL 5' - 0 " CONC. STAIRS 1 RISER W/ HANDRAILS 2'-10" HIGH HANDRAIL TRAFFIC GUARDRAIL 42" HIGH TRAFFIC RAIL 42" HIGH TRAFFIC GUARDRAIL 20'-6"9'-6" 7' - 0 " 17 ' - 0 " SL O P E 10" REINF. CONC. STRUCTURAL SLAB SEE STRUCTURAL SL O P E SL O P E SL O P E SL O P E WATER DEFLECTOR TYP. AT DOORS SLOPE FLOOR TO TRENCH DRAIN, TYP. -4'-0" SIDEWALKS, SEE CIVIL CONCRETE APRON, SEE CIVIL SIDEWALKS, SEE CIVIL RETAINING WALLS, SEE STRUCTURAL RETAINING WALLS, SEE STRUCTURAL LOADING DOCK CONCRETE APRON, SEE CIVIL FOUNDATION DRAIN, TYP. JERSEY BLOCK WALL BY OWNER METAL PARTITIONS BY EQUIP. VENDOR METAL PARTITIONS BY EQUIP. VENDOR CONC. STAIRS 2 RISERS . .. . 739.30 . . . . 740.00 739.00 739.00739.00 741.00741.00 738.75738.75 74 0 . 8 3 ... 741.00741.00 741.00 739.00 739.00 739.00 738.75 738.75 739.00 ....739.00 739.00 739.00 739.40 73 9 . 9 4 740.50 740.50 . 741.50 741.50 741.50741.50 740.50 740.73 740.50 STEEL CLOSURE PLATE BY EQUIPMENT PROVIDER STEEL CLOSURE PLATE BY EQUIPMENT PROVIDER 5'-5" 9'-0" 9'-0" 5'-7" 5'-1" 9'-0" 9'-0" 5'-1" 5'-3" 9'-0" 9'-0" 4'-11" 5'-1" 9'-0" 9'-0" 5'-1" 5'-1" 9'-0" 9'-0" 5'-1" 5'-6" 9'-0" 9'-0" 5'-6" 5'-1" 18'-0" 4'-7" 5'-5" 18'-0" 6'-7" 5'-0" 5'-0" 3'-4" 5'-0" 5'-0" 3'-4" 9"18'-0"10'-8"18'-0"10'-4"18'-0"10'-0"18'-0"10'-2"18'-0"10'-7"18'-0"10'-7"18'-0"10'-0"18'-0" 4'-3" 29'-0" 1'-4"29'-0"27'-8"21'-8"8'-4" 5'-0" 5'-0" 3'-4" 5'-0" 5'-0" 3'-4" 14'-6"14'-6"14'-1"14'-1"14'-1"14'-1"28'-2"28'-2" 10 ' - 0 " 10'-8" 11 ' - 0 " 15 6 ' - 4 " 9'- 4 " . 1' - 6 " 11 " 2' - 3 " 2' - 5 " ........ SL O P E 2 ' - 6 " (7 3 9 . 0 0 T O 7 4 1 . 5 0 ) SL O P E 2 ' - 6 " (7 3 9 . 0 0 T O 7 4 1 . 5 0 ) -8"-8"-12"-8" .... BB ELEC. ROOM 10 ' - 4 " 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 9' - 0 " 1' - 0 " 10 ' - 0 " 10 ' - 0 " 10 ' - 0 " 9' - 6 " 10 ' - 0 " 10 ' - 0 " 10 ' - 0 " CATWALK DASHED ABOVE 8'-0" 7'-6" 740.50 A7.51 2 FLUSH MOUNTED GIRTS ALONG EXTERIOR WALL TRENCH DRAIN SEE CIVIL -12" A7.51 8 F.D. F.D. F.D.F.D. D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S. D.S.D.S.D.S.D.S. D.S. D.S. D.S.D.S.D.S.D.S.D.S. 9'-4" 6' 8" WIDE TRENCH DRAIN 3'-8". 8" 15'-0" 30'-0" 24 ' - 0 " SLOPE PIT TO SUMP PIT 12" MAX, SEE STRUCTURAL SUMP PIT SEE PLUMBING SLOPE PIT TO SUMP PIT 12" MAX., SEE STRUCTURAL SUMP PIT SEE PLUMBING A127 CONVEYOR PIT 1 111CONVEYOR PIT 2 112 PIT SLOPES TO SUMP/ DRAIN PIT SLOPES TO SUMP/ DRAIN 4'-10" 27'-4". . 732.00 . 732.00 5 A6.55 5' - 2 " 7 ' - 0 " 5 ' - 2 " AREA DRAIN SEE PLUMBING AREA DRAIN SEE PLUMBING 7' - 1 1 " 36 ' - 2 " 5'- 1 1 " 30 ' - 1 1 " 36 ' - 2 " 37 ' - 8 " 66 ' - 6 " 1 7 ' - 2 " 9'-2" 10'-0" 9'-0" 10'-0"18'-3 5/8" 20 ' - 2 " . 4' - 0 " 1 2 ' - 0 " . 12'-0" 6 6 21 ' - 0 " 4'- 8 " 25 ' - 0 " 15'-8".4'-8" WALL LEGEND 4' HIGH REINFORCED CONCRETE WALLS 3' HIGH REINFORCED CONCRETE WALLS 10' HIGH REINFORCED CONCRETE WALLS (SEE PLAN FOR THICKNESS) JERSEY BLOCK WALL BY OWNER NTS TRAFFIC RAIL CMU REINFORCED WALLS Scale Date 101 W. Worthington Avenue Suite 240 Charlotte, NC 28203 phone: (704) 333-3360 fax: (704) 333-3362 construction@dasarchitecture.com DAS Project Number O'Leary Resource Recovery Center 3307 Darby Avenue Charlotte, North Carolina 28216 Shell/ Core/ Upfit Package 04.14.2016 As indicated A1.01 Overall Architectural First Floor Plan 04/06/2016 14 205 00 3/32" = 1'-0"1 Overall Architectural First Floor Plan No. Description Date 5 BD-SC.001 05/20/16 6 Revision - Pits 5/27/16 COURTESY FIELD SET