Loading...
HomeMy WebLinkAbout7907_StericycleAppl_DIN25953_20160215.pdf Rev:0 February 2016 SOLID WASTE TRANSFER STATION PERMIT APPLICATION FOR STERICYCLE ENVIRONMENTAL SOLUTIONS, INC 211 Rockingham Drive Reidsville, NC 27320 Prepared by Jeffrey Davis Scanned By Date DOC ID Permit Backus 04/12/2016 25953 7907-TRANSFER-2016 i Table of Contents Section I – General Information .............................................................................................................. 1 Section 2 – Property Information and Maps ........................................................................................... 1 Section 3 – Operation Plan ................................................................................................................. 3 Section 4 – Sedimentation and Erosion Control Plan ...................................................................... 3 Section 5 – Financial Assurance ......................................................................................................... 3 Section 6 – Traffic Study...................................................................................................................... 4 Section 7 – Signature Pages ................................................................................................................ 4 APPENDIX I – LAND DEED APPENDIX II – LAND SURVEY APPENDIX III – USGS TOPOGRAPHICAL MAP APPENDIX IV – ZONING CONFORMANCE APPENDIX V – FEMA FLOOD INSURANCE RATE MAP APPENDIX VI – OPERATION PLAN APPENDIX VII - SIGNATURES Page 1 Section I – General Information Name of Proposed Facility: Stericycle Environmental Solutions, Inc. Applicant: Stericycle Environmental Solutions, Inc. 211 Rockingham Drive Reidsville, NC 27320 Contact: Jeffrey Davis, Tel: 954.850.5632, Email: Jeffrey.Davis@Stericycle.com Operations Contact: Johnny Carter, General Manager 211 Rockingham Drive Reidsville, NC 27320 Telephone: 336.409.1870, Email: JCarter@Stericycle.com Landowner: Edmund Jin 45875 Northport Loop East Freemont, CA 94538 Telephone: Fee Invoices: Send to Operations Contact Section 2 – Property Information and Maps The facility is located on the south side of Rockingham Drive, SE of the city of Reidsville NC. The legal description of the property is: COMMENCING AT A ¾” IRON ROD ON THE NORTHERN RIGHT-OF-WAY OF NC HIGHWAY 87 (BARNES ROAD); THENCE S 1°53’45” W, 122.46 FEET TO A NEW IRON PIPE LOCATED ON THE SOUTHERN RIGHT- OF-WAY OF SAID NC HIGHWAY 87 (BARNES ROAD), SAID NEW IRON PIPE BEING THE NORTHEASTERN CORNER OF EDMUND JIN & EVA LU, PARCEL NO. 157383 (DEED BOOK 1328, PAGE 1399), THE NORTHWESTERN CORNER OF KINNARNEY & JERNIGAN PARTNERSHIP, PARCEL NO. 174024 (DEED BOOK 1386, PAGE 591), AND BEING THE POINT AND PLACE OF BEGINNING; THENCE LEAVING SAID NC Page 2 HIGHWAY 87 (BARNES ROAD) RIGHT-OF-WAY AND WITH THE WESTERN PROPERTY LINE OF SAID KINNARNEY & JERNIGAN THE FOLLOWING TWO (2) COURSES AND DISTANCES: 1) S 2°07’00” W, 543.39 FEET TO A ¾” IRON PIPE; THENCE 2) S 2°07’50” W, 219.30 FEET TO A ¾” IRON PIPE, SAID PIPE BEING A POINT IN THE WESTERN PROPERTY LINE OF SAID KINNARNEY & JERNIGAN AND THE NORTHEASTERN CORNER OF WELLS FARGO BANK, N.A., & JOHN F. WATLINGTON III, PARCEL NO. 157359 (D.B. 1442, PG. 585); THENCE LEAVING SAID KINNARNEY & JERNIGAN AND WITH THE NORTHERN PROPERTY LINE OF SAID WELLS FARGO BANK, N.A., & WATLINGTON, THE FOLLOWING TWO (2) COURSES AND DISTANCES: 1) S 69°00’39” W, 711.37 FEET TO A ¾” IRON PIPE; THENCE 2) N 72°00’28” W 339.66 FEET TO A ¾” IRON PIPE ON THE EASTERN RIGHT-OF-WAY OF ROCKINGHAM ROAD (S.R. 2804), SAID PIPE BEING THE NORTHWESTERN CORNER OF SAID WELLS FARGO, N.A., & WATLINGTON; THENCE LEAVING SAID WELLS FARGO BANK, N.A., & WATLINGTON AND WITH THE EASTERN RIGHT-OF-WAY OF SAID ROCKINGHAM ROAD (S.R. 2804) WITH A CURVE TO THE LEFT HAVING A RADIUS OF 480.00 FEET AND A LENGTH OF 32.62 FEET, TO A ¾” IRON PIPE. THE CHORD OF SAID CURVE BEING ON A BEARING OF N 10°05’56” W, AND HAVING A DISTANCE OF 32.62 FEET; THENCE N 12°06’19” W, 65.74 FEET, TO A ¾” IRON PIPE; THENCE WITH A CURVE TO THE RIGHT HAVING A RADIUS OF 320.00 FEET AND A LENGTH OF 452.95 FEET, TO A NEW IRON PIPE. THE CHORD OF SAID CURVE BEING ON A BEARING OF N 28°28’16” E, AND HAVING A DISTANCE OF 416.07 FEET; THENCE N 68°59’46” E, 343.43 FEET TO A ¾” IRON PIPE; THENCE WITH A CURVE TO THE LEFT HAVING RADIUS OF 480.00 FEET AND A LENGTH OF 263.71 FEET, TO A ¾” IRON PIPE. THE CHORD OF SAID CURVE BEING ON A BEARING OF N 53°12’23” E, AND HAVING A DISTANCE OF 260.40 FEET; THENCE N 37°27’38” E, 302.84 FEET TO A NEW IRON PIPE; THENCE N 84°27’38” E, 28.75 FEET TO A NEW IRON PIPE, SAID PIPE BEING ON THE SOUTHERN RIGHT-OF-WAY OF SAID NC HIGHWAY 87 (BARNES ROAD); THENCE LEAVING THE EASTERN RIGHT OF WAY OF SAID ROCKINGHAM ROAD (S.R. 2804) AND WITH THE SOUTHERN RIGHT-OF-WAY OF SAID NC HIGHWAY 87 (BARNES ROAD) S 52°37’39” E, 119.11 FEET TO A NEW IRON PIPE, SAID IRON PIPE BEING THE POINT AND PLACE OF BEGINNING. CONTAINING 14.76, MORE OR LESS, BEING 642,947 SQUARE FEET. A copy of the current land deed is provided in Appendix I. Appendix II contains a current land survey for the subject property. The property was previously used as a warehouse for finished goods (textiles). The property is a 14.753 acre tract of land consisting of a 113,496 square foot building and one hundred paved parking spaces and buffered green space from the property line. The building consists of a concrete floor, masonry and steel walls and a prefabricated metal roof. The building contains approximately 11,000 square feet of office space and a Page 3 102,000 square foot warehouse. The solid waste activities will be conducted within the east section of the warehouse space (approximately 50,000 square feet) and the remaining space is reserved for proposed future expansion. The storage areas occupy approx. 20,000 square feet with the remainder utilized for processing and transfer activities. A copy of the USGS topographic map can be found in Appendix III. A letter from the City of Reidsville, North Carolina verifying the siting of the facility is in conformance with all zoning and local laws is provided in Appendix IV. A FEMA Flood Insurance Rate Map for the area in provided in Appendix V. Section 3 – Operation Plan The Operation Plan for the facility can be found in Appendix VI. Section 4 – Sedimentation and Erosion Control Plan The proposed transfer facility will conduct all activities indoors, so no land disturbance activities will occur; as a result, a sedimentation and erosion control plan is not applicable. Section 5 – Financial Assurance The closure of the facility will be managed in the following manner: All receipt of material will cease All on-site inventory will be shipped off-site to landfill for final disposal A third party industrial service provider will powerwash the operating areas of the facility and equipment. The rinsate will be shipped offsite for disposal Page 4 The associated closure cost = inventory disposal cost + clean-up cost =maximum on-site inventory(Tons) X [Disposal Cost ($/Ton) + transportation cost ($/Ton)]+ 5X daily waste acceptance rate quantity(Tons) [Disposal Cost ($/Ton) + transportation cost ($/Ton)] + rinsate disposal+transportation cost+ cleaning cost =250 Tons X [$60/Ton + $33/Ton] + 5Days X 15 Tons/Day X [$60/Ton + $33/Ton] + 3gal/minX120minutesX$0.15/gal + $350/tote X 2 totes + $100/hrX5hours = 250 Tons X $93/Ton + 75 Tons X $93/Ton + 360 galX $0.15 gal + $350X2 +$100X5 = $23,250 + $6,975 + $54 + $700 + $500 = $31,479 A surety bond will be issued to NCDEQ to satisfy the financial assurance requirements for closure. Section 6 – Traffic Study Stericycle is requesting an exemption from a traffic study was due to number of truck arrivals per day (2) which will have negligible impact on the highway route (US 29) which has an Average Annual Daily Traffic of 20,000 vehicles (AADT 2014). Section 7 – Signature Pages Appendix VII contains signature pages for applicant and landowner. APPENDIX I LAND DEED APPENDIX II LAND SURVEY APPENDIX III USGS TOPOGRAPHIC MAP N SUBJECT PROPERTY PORTION OF 7.5-MINUTE (TOPOGRAPHIC) MAP UNITED STATES DEPARTMENT OF THE INTERIOR GEOLOGICAL SURVEY SCALE 1 : 24,000 REIDSVILLE QUADRANGLE NORTH CAROLINA (1972 PHOTOREVISED 1994) SITE LOCATION 211 ROCKINGHAM DRIVE REIDSVILLE, NORTH CAROLINA 27320 DATE JUNE 11, 2015 APPENDIX IV ZONING CONFORMANCE APPENDIX V FEMA FLOOD INSURANCE RATE MAP F a c i l i t y : 2 1 1 R o c k i n g h a m D r i v e R e i d s v i l l e , N C 2 7 3 2 0 APPENDIX VI OPERATION PLAN OPERATION PLAN FOR STERICYCLE ENVIRONMENTAL SOLUTIONS, INC 211 Rockingham Drive Reidsville, NC 27320 Prepared By: Jeffrey Davis Date: February 2016 2 Introduction Stericycle Environmental Solutions, Inc. (Stericycle) located at 211 Rockingham Drive, Reidsville NC (Facility) operates a packaging by-product recovering facility on a leased property in Rockingham County. The facility currently accepts consumer products for baling and repackaging which are then sent to a recycler. Stericycle desires to expand its offerings to include the management and disposal of consumer products that qualify as non-hazardous wastes when they are received at the facility and as such, are subject to North Carolina Department of Environmental Quality Solid Waste Rules (15A NCAC 13B) Waste Information & Service Area The facility proposes to accept consumer by-products in various sized containers that are typically palletized and not useable for various reasons, expired, off-spec, production overruns, discontinued, etc.). These consumer products are mainly personal care products – health & beauty, OTC medication from the manufacturer. These product wastes would be separated, shredded, re-packaged, consolidated or transferred off-site to a recycler or disposal facility. The facility intends to initially service Guilford, Edgecombe and Vance Counties. The facility proposes to accept approximately 15 Tons of consumer by-product daily. Hours of Operation The facility intends to operate approximately 255 days per year. The hours of operations are 07:00 to 17:00, Monday to Friday. The facility will normally be closed on New Year’s Day, Memorial Day, Independence Day, Labor Day, Thanksgiving Day and Christmas Day. Waste Management Stericycle pre-approves all material destined for receipt at the facility. Only non- hazardous consumer products & by-products are pre-approved for receipt at the facility. Pre-approval is based on SDSs and customer knowledge of the product. Only pre-approved material will be scheduled for pick-up at the customer’s site. Material will arrive via truck palletized or in bins/boxes containing various sized containers. Every inbound load is inspected for packaging integrity as well as conformance to the pre-approved material. The packages are placed on a table 3 for visual inspection then segregated depending on the type of management activity. Foreign material that may be found in containers of consumer products are segregated and held awaiting approval for disposition. Shredding – product destined for shredding is staged at the shredder then processed. The shredded material is stored in a bulk container for shipment offsite for waste-to-energy. Separation – product may be de-manufactured into separate components (plastic, metal, batteries. The plastic is bulked into a container and sent off-site to a plastics recycler. The metal is bulked into a bin and sent to a scrap metal dealer. Batteries are packaged according to type and shipped off-site to a recycler. Baling – OCC, plastic and paper from product packaging is baled and shipped off- site to a recycler. Consolidation – waste products that cannot be recycled are consolidated into bulk containers and shipped to landfill for final disposal. Product Storage – product may be stored on behalf of the manufacturer for return at a later date. A material flow diagram (Figure 1) identifies the flow of product from facility arrival to off-site shipment to a recycler or disposal facility. Material that cannot be recycled or recovered is shipped to the following landfills based on their service area: • East Carolina Regional Landfill • Foothills Environmental Landfill • City of Greensboro Landfill Recyclables are shipped to Sonoco Recycling, Greensboro NC Consumer product solids that meet waste-to-energy specifications are sent to Covanta Energy - Fairfax 4 All inbound by-products for recycling and disposal are pre-approved into all recycling and disposal outlets. Material that does not have a pre-approved outlet will not be received at the facility to prevent excess storage times and eliminate speculative recycling. Equipment The facility equipment includes a shredder, horizontal baler, vertical baler and compactor for consumer by-products, OCC, plastic and paper processing. Truck loading and unloading occurs through the use of pallet jacks and forklifts. Material handling equipment will include drum dollies and pallet jacks. Sanitary Control The facility does not receive putrescible waste; as a result, the vector controls are limited to normal pest control through third party contracts. Materials are received and stored in containers indoors and never dumped on the floor; as a result, there will be minimal occurrences of windblown material leaving the facility. Daily housekeeping includes tramp and debris removal in the facility and routine inspection of the property perimeter for tramp and debris removal. Signage The facility entrance sign will be in conformance with NC DEQ solid waste rules and include • operating hours • permit number • emergency number • acceptable wastes (Acceptable Materials - recyclables and consumer product wastes) • Unacceptable Materials – municipal solid waste, hazardous waste, PCB waste, medical waste and petroleum products’. 5 Directional signs to the loading/unloading area of the facility will also be posted in strategic areas noting speed limit Site Security & Access Roads All entrances to the warehouse are locked at all times and can only be accessed through a preassigned code. All visitors, drivers are escorted while on the property. Security cameras are strategically located inside the facility and around the outside perimeter and continually monitor and record activity. Security is provided through fencing and barriers. The entrance gate is locked outside of operating hours. The main access road to the site is Rockingham Drive from Barnes Street. Truck traffic is anticipated to be 2 trucks per day. Direct access to the facility entrance will be maintained as well as all paved areas surrounding the facility. Training A training summary for all employees is included at the end of the Operation Plan Contingency Plan A contingency plan for the Facility is included at the end of the Operation Plan Operating Records All operating records, permits, correspondences etc. will be maintained electronically and/or hardcopy in the facility manager’s office. Ou t b o u n d In b o u n d T r a i l e r s Tr a i l e r s FI G U R E I - MA T E R I A L FL O W DI A G R A M Of f i c e Ar e a Wa r e h o u s e Off i c e Stericycle ESOL Policies and Procedures EMPLOYEE TRAINING REQUIREMENTS Page 1 of 2 TRAINING COURSE FREQUENCY Access to Exposure and Medical Records Every Year Accident and Injury Reporting Requirements Within 30 Days Of Hire Date Backing Training G.O.A.L. Every Year Bloodborne Pathogens Every Year Defensive Driving Course Every 3 Years Distracted Driving Every 3 Years Lockout Tagout Every Year DOT Hazardous Materials - ESol Every 3 Years Driver Qualifications Once Emergency Action / Contingency Plans Every Year Fire Extinguishers - Portable Every Year Hazard Communication Within 30 Days Of Hire Date Forklift Training Every 3 years Stericycle ESOL Policies and Procedures EMPLOYEE TRAINING REQUIREMENTS Page 2 of 2 TRAINING COURSE FREQUENCY Job Safety Analysis JSA Every Year Personal Electronic Device Training Once Personal Protective Equipment - ESol Every Year Proper Lifting Every Year Safety and Compliance Matters Program Every Year Slip, Trip, Fall or Walking/Working Surfaces Every Year Spill Response Every Year Stop Work Authority Every Year Substance Abuse Prevention Within 30 Days Of Hire Date Temperature Extremes (Cold/Heat Stress) Every Year Vehicle Condition Reports - VCRs Every Year Wellness Training for Drivers Once Whistleblower Policy and Procedures Once Workplace Violence Prevention Within 30 Days Of Hire Date Page 1 of 2 Contingency Plan – Reidsville NC Transfer Station Objective: This Contingency Plan (Plan) is designed to minimize the risk of human injury, property damage, or harm to the environment as a result of fire, explosion, any unplanned sudden or non-sudden release of waste/product, or other emergency. The provisions of the Plan must be carried out as described immediately whenever there is a fire, explosion, release of waste/product, or other emergency that could threaten human health, property, or the environment. Emergency Coordinator: Emergency Coordinators are responsible for the following: 1) At minimum, one emergency coordinator must be physically present at the facility or be on call with the ability to respond within a reasonable amount of time. 2) The acting Emergency Coordinator must coordinate all emergency response measures from the scene. 3) The Emergency Coordinator must be familiar with: The Contingency Plan Facility operations and activities Location and characteristics of all materials on site. Facility layout Have the authority to commit any and all resources necessary to carry out the Contingency Plan. Procedures in Response to Fires, Spills, and Explosion or Equipment Failure at Facility Employees are not trained as first emergency responders and will always utilize external sources to respond to fires or explosions Fire In the event of a fire, employees must evacuate the building immediately and call 911. Employees are not trained as emergency first responders • Proceed to the nearest emergency exit (See Facility Diagram). • Fire extinguishers and alarm pull stations are located throughout the building. Fire extinguishers are provided to aid in escape from emergency fire situations. • Employees are not expected to extinguish fires. • If you discover a fire, alert others in your area and evacuate the building. You may pull the fire alarm if it is accessible. Page 2 of 2 • Help others evacuate if they are injured or incapacitated • Report to the primary assembly area located in the Southwest area of the property. If the Southwest assembly area (outside the SW doors) is not available, report to the secondary assembly area in the Northeast parking area. Roll call will be taken at the assembly area to ensure that all employees are accounted for, and that no one is left inside the building. Do not leave the assembly area until you are given the all clear. The Emergency Coordinator or designee will give the all clear to leave assembly area. Spills/Releases The Reidsville facility does not manage hazardous materials and are not responsible for responding to hazardous materials spills. In the event of a spill: • Report spills to your manager/supervisor • Minor, non-emergency spills can be cleaned up by warehouse personnel after notifying the supervisor/manager. • Call 911 for emergency spills. An emergency spill is a spill that is out of control, leaving the property or has the potential to leave the property and can cause harm to people, property or the environment. • Spill kits are located throughout the building to clean up and control spills • Refer to the spill/release reporting flowchart Medical Emergencies In the event of a medical situation, contact your manager/supervisor. The supervisor/manager will determine whether it is an emergency or non-emergency. For injuries or accidents, notify your manager and seek medical attention. Call 911 for emergency medical situations. Emergency Phone Numbers Emergency Contact Phone Number Fire/Ambulance Reidsville Fire Department 911 Police – Emergency Reidsville Police Department 911 Police – Non-emergency Reidsville Police Department 336-349-1010 First Aid/Minor Spills Johnny Carter 336-409-1870 Urgent Care Facility Triad Urgent Care 336-701-2662 EHS Representative Justin Pickens 916-208-2458 NC DEQ Environmental Emergency 800-858-0368 FACILITY DIAGRAM Fire Extinguisher Eyewash Station Spill Kit Secondary Assembly Area Primary Assembly Area N Exit Exit Exit Exit Exit Exit Exit Exit Fire Pump Room APPENDIX VII SIGNATURE PAGES