Loading...
HomeMy WebLinkAbout3902_Granville_Butner_MSWLF_May23LFG_FID1819483_20231023GARRETT Epp o'/ 2 & MOORE Engineering for the Power and Waste Industries May 2511, 2023 Ms. Jackie Drummond North Carolina Department of Environment and Natural Resources Division of Waste Management, Solid Waste Section 1646 Mail Service Center Raleigh, NC 27699-1614 RE: Landfill Gas Monitoring Report 2nd Quarter Sampling Event of 2023 Granville County — Butner Closed MSW Landfill Permit # 39-02 Dear Ms. Drummond: Attached please find the Landfill Gas Monitoring Log and Gas Probe Location Map for the 2nd quarter monitoring event that occurred on May 25th, 2023, at the Granville County Butner Landfill (Permit number 39-02) for inclusion in your records. Methane was detected in GP-4 above the LEL during this event. No action is recommended at this time. No other locations indicated explosive gas concentrations in excess of the associated action levels. Additionally, hydrogen sulfide was not detected in any monitored location during this event. Landfill gas monitoring will continue on a quarterly basis for the Butner Landfill. If you have any questions, please do not hesitate to call me at 919-792-1904. Sincerely, Garrett & Moore, Inc. Craig M. Fortner, P.E. Cc: Jason Falls, Granville County 1029 W. South Street, Raleigh, North Carolina 27603 • O: 919-792-1900 • F: 866-311-7206 Electronic Data - Email CD (data loaded: Yes / No DENR Division of Waste Management - Solid Waste Doc/Event #: Environmental Monitoring Reporting Form Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132 -6). Instructions: • Prepare one form for each individually monitored unit. • Please type or print legibly. • Attach a notification table with values that attain or exceed NC 21, groundwater standards or NC 213 surface water standards. T he notification must include a preliminary analysis of the cause and significance of each value. (e.g. naturally occurring, off -site source, pre-existing condition, etc.). • Attach a notification table of any groundwater or surface water values that equal or exceed the reporting limits. • Attach a notification table of any methane gas values that attain or exceed explosive gas levels. This includes any structure s on or nearby the facility (NCAC 13B .1629 (4)(a)(i). Send the original signed and sealed form, any tables, and Electronic Data Deliverable to: Compliance Unit, NCDENR-DWM, Solid Waste Section, 1646 Mail Service Center, Raleigh, NC 27699-1646. Solid Waste Monitoring Data Submittal Information Name of entity submitting data (laboratory, consultant, facility owner): Garrett & Moore, Inc., consultant Contact for questions about data formatting. Include data preparer's name, telephone number and E-mail address: Name: Craig M. Fortner E-mail: cfortner@garrett-moore.com Facility name: Facility Address: Phone: 919-815-4221 NC Landfill Rule: Actual sampling dates (e.g., Facility Permit # (.0500 or .1600) October 20-24, 2006) Butner Landfill 2796 Old NC 75 39-02 .1600 5/25/2023 Butner, NC 27509 Environmental Status: (Check all that apply) ❑ Initial/Background Monitoring ❑ Detection Monitoring Assessment Monitoring Corrective Action of data submitted: (Check all that apply) Groundwater monitoring data from monitoring wells �X Groundwater monitoring data from private water supply wells El Leachate monitoring data El water monitoring data Methane gas monitoring data Corrective action data (specify) Other(specify) Notification attached? e No. No groundwater or surface water standards were exceeded. Yes, a notification of values exceeding a groundwater or surface water standard is attached. It includes a list of groundwater and surface water monitoring points, dates, analytical values, NC 2L groundwater standard, NC 2B surface water standard or NC Solid Waste GWPS and preliminary analysis of the cause and significance of any concentration. © Yes, a notification of values exceeding an explosive methane gas limit is attached. It includes the methane monitoring points, dates, sample values and explosive methane gas limits. Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. Furthermore, I have attached complete notification of any sampling values meeting or exceeding groundwater standards or explosive gas levels, and a preliminary analysis of the cause and significance of concentrations exceeding groundwater standards. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. Craig M. Fortner, PE Project Manager N (Print) Title 919-815-4221 (Area Code) Telephone Number 5/25/2023 Affix NC Licensed/ Professional Engineer Seal Signature Date 1029 W. South Street, Raleigh, NC 27603 Facility Representative Address NC Firm C-2910 NC PE Firm License Number (if applicable effective May 1, 2009 \ APPROXIMATE MW 5 \ \ LOCATION \I PROPERTY LINE _ \� GP-2 i SW-1 AGV AGV I\ \ APPROXIMATE\ / GV \ I ��YYYY-MW-4 LIMITS OF WASTE ` - G\ I I I \ I V / CREEK CENTERLINE) / ` I MW-3R SW-2 M . I MT2R \ \ Z J 0 Ai Jz I LEGENDLL J I- --- 0 / I \ I I I I \ \ \ �., _ 130 EXISTING 25' TOPOGRAPHIC CONTOUR z O �� \ EXISTING 5' TOPOGRAPHIC CONTOUR Q Z _ PROPERTY LINE J } APPROXIMATE LIMITS OF WASTE LLI z / zZ) EXISTING ROAD �— O MW-1R CENTERLINE OF STREAM D U \ / GROUNDWATER MONITORING WELL MW iR LOCATION AND IDENTIFICATION J GP-1 GAS PROBE LOCATION AND > ���IDENTIFICATION z � GV GAS VENT \ - O� SW-1 SURFACE WATER MONITORING POINT Gp-q � — / (NM) NOT MEASURED m / V 5 Jt APPROXIMATEGPE LIMITS OF WASTENOTES 1. TOPOGRAPHIC CONTOUR INTERVAL = 5 FEET 2. STATIC WATER LEVELS MEASURED ON 12/12112. 777 3. ELEVATION RELATIVE TO MEAN SEA LEVEL. GfRAPHIC SCALE 4. TOPOGRAPHIC CONTOURS SHOWN IN THIS MAP ARE BASED ON 50 .100 200 2007 DATA OBTAINED FROM NCDOT WEBSITE. _5. BOUNDARYSURVEYPROVIDEDBY BATEMAN CIVIL SURVEY (FEET) COMPANY DATED MARCH 15, 2013. v PROJECT NO. 660.1201.12 SCALE AS NOTED DRAWING NO. 1 0 w w NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: This form and any information attached to it are 'Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Facility Name: Granville County —Butner Closed MSWLF Permit Number: Sampling Date: May 25, 2023 NC Landfill Rule (.0500 or.1600): Sample Collector Name & Position: John Nguyen, Garrett & Moore Gas Meter Type & Serial Number: GEM5000 Gas Meter Calibration Date: Field Calibration Date & Time: 5/25/2023; 0900 Field Calibration Gas Type (15115 or35/50): 35/50 Field Calibration Gas Canister ExpirationDate: 2/2024 Gas Meter Pump Rate: 50 cc/min Ambient Air Temperature: 63' Barometric Pressure (in. or min Hg): 29.53 in. Weather Conditions: Partly Cloudy Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office). Attach a test location map or drawing. Report methane readings as both % LEL and % CH4 by volume. Convert % CH4 (by volume) to % LEL as follows: % methane (by volume) x 20 = % LEL. *Hydrogen Sulfide (H2S) gas monitoring may be required for Construction & Demolition Landfills (CDLFs). See individual permit conditions and/or Facility LFG monitoring plan. Location or LFG Well ID Sample Tube Purge Time of Day Time Pumped P (sec) Initial /o LEL " Stabilized /o LEL " % CH4 (volume) 0 /o CO2 (volume) 0 /0 02 (volume) ppm H2S (volume) NOTES GP-1 2 min 0937 60 0 0 0 0.6 20.4 0 GP-2 2 min 0933 60 0 0 0 14.5 15.2 0 GP-3 2 min 0930 60 0 0 0 0.1 20.5 0 GP-4 2 min 0921 60 0 > 100 10.0 18.2 9.7 0 GP-5 2 min 0924 60 0 0 0 19.3 4.0 0 GP6 2 min 0927 60 0 0 0 0.9 18.1 0 Scales 2 min 0915 60 0 0 0 0.1 21.0 0 Shed 2 min 0918 60 0 0 0 0.1 21.0 0 NOTE: If needed, attach additional data forms to include additional LFG monitoring data locations for the facility. ACTION LEVELS: Methane: >1.25% by volume (inside structures) AND >5% by volume (atfacility boundary) Hydrogen Sulfide: >1% by volume (inside structures) AND >4% by volume (at facilityboundary) Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there are significant penalties for making any false statement, representation, or cert' ation includX the possibility of a fine and imprisonment. r Professional Engineer RE TITLE