Loading...
HomeMy WebLinkAbout9242_WallRecycGarner_RevisedOpsPlan_20220812Section 3.0 FACILITY OPERATIONS PLAN Wall Recycling MIFF — Garner Road Permit No. 9242-MWP-2020 Permit No. 9242-Transfer-2020 Wake County, North Carolina WJD Holdings — Property Owner Wall Recycling, LLC — Facility Operator 2126 Garner Road Raleigh, North Carolina 27610 Prepared by: HNIZR' ENGINEERING iaxnvArrve w,.sra soLunoxs 205 Walnut Street, Statesville, NC 28677 1704.464.6800 3.0 MIXED WASTE PROCESSING & TRANSFER STATION FACILITY OPERATIONAL PLAN 3.1 General Facility Operations .................... .......................................................................... 2 3.2 Contacts.............................................................................................................................2 3.3 Facility Operating Hours ................................ 3.4 Facility Access.................................................................................................................3 3.5 Signage..............................................................................................................................4 3.6 Personnel...........................................................................................................................4 3.7 Equipment.........................................................................................................................4 3.8 Health and Safety ................................... ..........4 3.9 Waste Acceptance & Traffic Flow....................................................................................4 3.10 Waste Screening & Processing.........................................................................................5 3.11 Waste Disposal..................................................................................................................6 3.12 Stormwater Management ......................................................................................... ....7 3.13 Erosion and Sediment Control..........................................................................................7 3.14 Emergency Response........................................................................................................7 3.15 Windblown Litter..............................................................................................................8 3.16 Vector Control............................................................................................................. ...8 3.17 Personnel Training............................................................................................................8 3.18 Operating File ........... ................. ................................. ....................................... I .......... -.8 APPENDICES Appendix A Debris Screening Form Appendix B Fire Notification Form Appendix C City of Raleigh, UDO & Local Government Approval Appendix D Asbestos Containing Material Guidelines Appendix E Engineer's Estimate of Probable Costs for Closure Appendix F Legal Description Wall Recycling, LLC Facility Operational Plan June 2020, Rev. 2022 1 Wall Recycling MWP & TS 3.0 MWP AND TRANSFR STATION OPERATIONS PLAN The Facility Operations Plan is a reference guide for Site personnel, to be used in the performance of their daily activities, and to assist with maintaining compliance with Local, State and Federal Regulations and permits. 3.1 General Facility Operations The Facility is a permitted, Mixed Waste Processing (MWP) Area and Transfer Station. The MSW operations will occur inside the metal building or under roof and will be unaffected during rain events. The C&D waste and C&D like wastes will be unloaded for initial screening and processing onto a concrete pad located outside of the building. These materials will be separated for resale as recovered materials and loaded into containers or trailers for shipment off -site to end use recycling companies or for final disposal. Some materials may be further processed inside the MRF using equipment and hand picking/sort lines. Outside processing of waste materials will cease during precipitation events and a tarp will be deployed over the waste to reduce contact with stormwater. MSW and C&D residuals with no value will be loaded onto transfer trailers or open top containers for transfer to an appropriate permitted C&D or MSW landfill. Waste and recoverable materials will be received from North Carolina Counties within a 100-mile radius of this facility and will include: Wake, Chatham, Durham, Orange, Lee, Harnett, Johnston, Wilson, Nash, Franklin, Granville, Vance, Warren, Alamance, Person, Caswell, Guilford, Cumberland, Sampson, Wayne, Lenoir, Greene, Pitt, Edgecombe, Halifax, Duplin, Pender, New Hanover, Brunswick, Columbus, Bladen, Hoke, Moore, Randolph and Davidson. 3.2 Contacts Owner/Applicant: Dan Wall Wall Recycling, LLC 2310 Garner Road Raleigh, North Carolina 27610 919-552-2149 dan-.2-Maflrec clin .cam Wall Recycling, LLC Facility Operational Plan June 2020, Rev. 2022 2 Wall Recycling MWP & TS Site Manager: Dan Jarboe Wall Recycling, LLC 231-0 Garner Road Raleigh, North Carolina 27610 919-906-2747 djarboeicr wallrecycling.com NCDEQ Solid Waste: Diana Felix 217 West Jones Street 1646 Mail Service Center Raleigh, North Carolina 27699-1646 919-707-8257 Diana. F e l ix, rr I n c deer. go v 3.3 Facility Operating Hours Normal hours of operation will be 4:00 am to 8:00 pm, Monday through Friday and 6:00 am to 6:00 pm on Saturday. Due to the rise in construction activity in and around the Raleigh market area, this facility has seen an increase in material volumes and will operate on a 24-hour basis to keep up with the demand for this service. Holidays observed will include New Year's Day, Thanksgiving and Christmas. Additional days may be added based on facility demand. The Facility will operate an estimated 310 days per year. 3.4 Facility Access Facility access is from EBY Drive off Garner Road. Entry into the MWP and Transfer Station area is controlled by the scalehouse attendant. Fencing and gates are used to prevent unauthorized access. Roads and/or driving areas are either concrete or asphalt paved and will be maintained in good condition. Wall Recycling, LLC Facility Operational Plan June 2020, Rev. 2022 3 Wall Recycling MWP & TS 3.5 Signage A sign will be posted at the Facility entrance with the Emergency Contact Name and Phone Number, Permit Number, Types of waste accepted, types of waste prohibited and operating hours. Traffic control signs will be used to manage the flow of traffic. 3.6 Personnel Personnel for the site will include a Manager of Transfer Station Operations, responsible for the daily operations of the Facility. In addition, the Facility will have a Site Supervisor, Scalehouse Attendant, Equipment Operators and Laborers. The Owner maintains Managerial and Administrative staff at their offices next door. Third party consultants and contractors may be used as necessary to complete identified tasks. 3.7 Equipment Typical equipment for the MWP and Transfer Station Facility will include an Excavator, Frontend Loader, Maintenance/Fuel Truck, Roll -off Truck, Transfer Trailers and Pick-up Truck. Equipment operations and maintenance will occur as per their respective manuals. 3.8 Health and Safety A Health and Safety Plan for Facility Personnel will be used to provide the necessary training required for compliance with the Occupational Safety and Health Administration (OSHA) and other State Health and Safety standards for this type of operation. 3.9 Waste Acceptance & Traffic Flow The MWP Area will receive C&D wastes and C&D like wastes for processing into resaleable products including recoverable materials and recyclables. MSW materials will be directed inside the metal building, onto the tipping floor area for unloading and loading into transfer trailers for disposal off -site. Wall Recycling, LLC Facility Operational Plan June 2020, Rev. 2022 4 Wall Recycling MWP & TS All incoming waste loads will be received at the scalehouse, noted as to County of origin, and directed to the MWP Area or the Transfer Station tipping floor for processing or loading. Like tons of waste will be directed to a permitted facility with a service area that can accept the waste based on its' origin. A tracking sheet will be developed and maintained as part of the operating record. Traffic flow arrows have been added to the Existing Conditions Drawing (Figure 2). This facility will be able to handle 1,500 tons per operating day with an estimated 200 in -bound truck loads and 75 out -bound transfer trailers. We estimate that 80% of the waste stream will be C&D and 20% MSW. The primary limiting factor to any transfer station is having a sufficient amount of trailers, tractors and drivers to move the waste out of the facility and returning empty trailers for loading. 3.10 Waste Screening & Processing Initial waste screening occurs at the scalehouse with the identification of the type of waste and a visual inspection of the load. Material that is determined to be a C&D waste or C&D like waste will be directed to the MWP Area. MSW will be directed to the Transfer Station tipping floor by the Scale Attendant. Secondary waste screening will occur at the unloading area and will typically be completed by the Equipment Operator. A Debris Screening Form, Appendix A, will be completed on 5% of the incoming loads to the transfer station based on the previous year's average daily intake volume as reported in the Facility Annual Report. Prohibited waste loads will not be allowed to unload at this Facility. In the event that prohibited waste is unloaded on the tipping floor or in the MWP area, it will be identified, kept separate from other acceptable wastes and/or recovered materials and reloaded (if possible) onto the truck that carried it in. If the material cannot be reloaded, it will be kept separated and contained away from the operating area until Site Management or DEQ decides on handling procedures. Notification to NCDEQ will be made for any prohibited waste loads received and a record maintained in the Operating file. The Wall Recycling scale ticket requires that the driver sign the ticket, "Certify that this load does not contain any unauthorized waste." Incoming materials will be unloaded on the MWP Area tipping floor. An excavator with a thumb attachment will remove, sort and reload metals and other Wall Recycling, LLC Facility Operational Plan June 2020, Rev. 2022 5 Wall Recycling MWP & TS recoverable and recyclable materials (including but not limited to, clean wood, concrete, unpainted brick/block, cardboard) from the waste stream for sale. Residual materials and materials with no value will be loaded into transfer trailers for permitted disposal locations off -site. C&D waste materials have a greater potential for containing asbestos. Known asbestos containing materials will not be processed at the MWP area and will be directed to a landfill facility that can receive this type of waste. The Guidelines for Handling Asbestos Containing Building Materials at C&D Recycling Centers in North Carolina is included in Appendix D. MSW will be unloaded onto the tipping floor and reloaded into transfer trailers using an excavator with a thumb attachment or a frontend loader. Loads that contain significant quantities of a recoverable or recyclable material (aluminum, steel cans, glass bottles and cardboard) will be separated using the excavator and reloaded into transfer trailers or open top containers for sale off -site. Residuals and waste with no value will be loaded onto transfer trailers for disposal at a permitted, MSW Landfill. The MSW tipping floor will be washed on a regular basis to maintain the facility in a sanitary condition. Wash down water and other waste generated liquids will be collected via the floor drain and the leachate storage tank for off -site treatment at a POTW. Any recovered or recyclable materials will be removed in quantity within a 1-year time frame from initial receipt at the Facility. 3.11 Waste Disposal C&D waste, C&D like waste or MSW that is processed at this facility will either be loaded into open top containers for resale or recycling off -site or will be loaded into transfer trailers for disposal at an appropriate, off -site, permitted landfill. All loads will be identified as to their County of origin so that "Like" tons can be directed to a disposal facility that can receive wastes from that County. Permitted C&D landfills that will be used for disposal include Gold Hill Road C&D (#7606), Red Rock Disposal (#9228), Brownfield Road (#9231) and Greenway Waste (#9230). Permitted MSW landfills that will be used for disposal of MSW and/or C&D include Upper Piedmont (#7304), Great Oak (#7607), Sampson County (#8202) and South Wake (#9222). Wall Recycling, LLC Facility Operational Plan June 2020, Rev. 2022 6 Wall Recycling MWP & TS No waste or recyclables will be disposed of at this Facility. Crushed concrete, stone and clean soils may be stockpiled onsite for sale to various landfill facilities and other customers in the area. 3.12 Stormwater Management Stormwater will be managed according to the Facility's General Stormwater Permit. Run-on will be directed away from the MWP Area using berms, stormwater channels or trench drains. A metal building with a concrete floor will be used for the MSW area. The trench drain was updated, based on NCDEQ comments received, to direct stormwater away from the waste material and to prevent additional leachate from being generated. Access roads will be concrete or asphalt. MWP areas for inert debris items may occur off the concrete or paved areas. These areas will have perimeter vegetative buffers and other measures as per the requirements of a general stormwater permit. 3.13 Erosion and Sediment Control No land disturbance activities are anticipated for this Facility. 3.14 Emergency Response In the event of an emergency, the Facility Manager will be notified. If outside assistance is required, 911 will be contacted. In most fire instances, on -site equipment will be utilized to control, contain and extinguish the fire if it occurs outside the building. Dirt covering is the preferred method for extinguishment. Water may also be used if dirt or an excavator is not available. If a fire occurs inside the building, 911 will be contacted to summon the City of Raleigh F.D. All fire events must be verbally reported to NCDEQ within 24 hours of the event with written notification on the prescribed form within 15 days. See Appendix B. Wall Recycling, LLC Facility Operational Plan June 2020, Rev. 2022 7 Wall Recycling MWP & TS 3.15 Windblown Litter MSW unloading will be protected from the wind by unloading and reloading MSW inside the metal building. The MWP` area is protected from the wind on two sides by other Facility buildings. The Facility also has a perimeter chain link fence and a recovered material berm to protect the railroad right of way from windblown litter. If windblown litter does occur, these materials will be collected and returned to the processing area at the conclusion of daily operations. 3.16 Vector Control Vectors will be controlled with specific traps for either insects or rodents. MSW materials will be loaded into transfer trailers or open top containers daily. No MSW will be allowed to remain on the floor of the transfer station overnight. 3.17 Personnel Training An NCDEQ, certified operator will be onsite during operating hours. Additional training will be conducted in-house or by third party consultants/vendors on an annual and as needed basis to educate current and new employees on the requirements contained within the NCDEQ Solid Waste permit, NCDEQ Stormwater permit, this Operations Plan and OSHA safety regulations. 3.18 Operating File An operating file will be maintained at the Facility and will include at a minimum, a signed copy of the Permit to Operate, the Operations Plan, other Facility permits, scale house records including tons received by type, origin and amount of waste received by County, disposal records, amount and type of material recovered or recycled, sale of material records, waste screening forms, inspections, correspondence, site drawings and other documents pertinent to the operation and compliance of this Facility. Wall Recycling, LLC Facility Operational Plan June 2020, Rev. 2022 8 Wall Recycling MWP & TS FIGURES Figure 1 Site Location Map Figure 2 Existing Conditions (also provided as PDF for clarity) Wall Recycling, LLC Facility Operational Plan June 2020, Rev. 2022 9 Wall Recycling MWP & TS Figure 1: Site Location Map aw • � � �'i 9�.'�' �°r _ _�°0 in .emu?.. , • r � � e l g it f `�� �"► r`y: Gilt 4.Ai;e� =�• �* �P� 's o—°v _.f— �y to Walnut Creek N f _ 4 St Wetland Center QCI[5�� m - 3 W,atar►W; • �c • � r �l pSjal.nui C'iee�• sr ► j1� o \ _ � � � - _ x � ...�alfaway�ipr '-• �n�i;.T =. _. _ - � ; ?�'�� _ 13ilitmore=Hills':' _ �y Hertford 1lillage i r 'rybe_Rd Pees 1^r'lye ; i Ve�•�+rAane]Ia: Ln n�Rd I 6 m r■ g -h a r r• `Bllfmore Hills • rrA, "� f '^ � • .:i _. � r'Y ' - ' ti • i ..� ��_ Rark 4 •� �' �., I , �• r y� ''fib ~ �: w Hertford C�i[la e'+ ° �'r..' • •- Kingwaa �:i. = fi s Ea"st'Parkland Foresi Park �� �.f-• '.:Park. �,rm - �ti 'arkland - '- - - K ' 25, yL ` -� 2• R�sh.gt -r� _ -- ^'�.,� R-r _ ..�• - _F,aC��ti7e'. i�r!',- :"�- •.Seah ■ JiZ,,� - �� - � ` ,i. .-i_.:4� � � -Hilito.pa� :S •�.=' I :II-'.. .. . --- - i1� _� � 1� y •� y ry •.S�R f `�� . �E �+iar � - nS— J 'i ils� a w�s� � z a _ �'r 'h _ - � s � .ram. s, . _ �_ - _ . .•� _ 2104000 2106000 2108000 2110000 2112000 211 S 0 BRA E3 N'. H j 2126 Garner Rd. E3 . . . . .. . . . . . . Chwk�r 11 t.7 a�T -AFT I Ir I ilk Elcrnsdk USGS The National Map: Na,tia'nal Boundaries Dataset, 3DEP Elevation Program, Names'IA ormA ion System, National Hydroq@aphy Dataset National Land Cover Database, National Structures,'Dalaset, and !National Transportation Dataset; -,,USGS Global Ecosysterns; I.P.S. "s Bureau TIGER/Line data OSF� Road Data; Natural Earth Data; U.S. Department of State Humaiiitarian Information Unit; a hd; NOAA National Centers for Environmental Information, U.S. Coastal Relief Model. Data P -T. refreshed February, 2020. 2104000 2106000 2108000 2110000 2112000 21114000 N ? 0.5 1 2 Kilometers W+E . SI 0 0.25 0.5 1 Mile s 0 1,250 2,500 5,000 Feet HNA ENGINEERING, PLLC Wall Recycling- 205 Walnut St. Statesville, NC 28677 2126 Garner Rd. (704)464-6800 RHoffmanCa)HNA-Engineering.com Figure 2: Existing Conditions Appendix A Appendix B Appendix C Appendix D Appendix E Appendix F APPENDICES Debris Screening Form Fire Notification Form City of Raleigh, UDO & Local Government Approval Asbestos Containing Materials Guidelines Engineer's Estimate of Probable Costs for Closure Legal Description Wall Recycling, LLC Facility Operational Plan June 2020, Rev. 2022 10 Wall Recycling MWP & TS GARNER RD. TRANSFER STATION PERMIT MODIFICATION WALL RECYCLING - GARNER RD. TRANSFER STATION SITE LOCATION WAKE COUNTY 26, INDEX OF SHEETS SHEET NUMBER SHEET TITLE 1 COVER SHEET 2 EXISTING CONDITIONS - AERIAL 3 EXISTING CONDITIONS 4 TRANSFER STATION TRAFFIC FLOW TRANSFER STATION PERMIT NO: 9242-TRANSFER-2020 2610 GARNER RD. RALEIGH, NC WALL RECYCLING DAN WALL n.d n ctn o' a�02 IL - - ZACHARY A. TAYLOR. III. B P6 * SCALET' = 80' JAMES L. CLARK ! DB,16346, PG 854 A' ,� fl40�PG. ;•.. DB 8851. PG 2002 BM 1982, p �- yy y' PIN: 1702-9 �_y BM 1946, PG 31 LEGEND � : e i .A 10[ • • . `♦ y # _ _ � PIN: 1TOa- 34� •[` ` "�� .r..�7..1. • s,>: FACILITY BOUNDARY 70D CONTOUR MAJOR ' 'YJ� - ►� " a - CONTOUR MINOR tow /f— EDGE OF CONCRETE X FENCE 16 r r OVERHEAD UTILITY . * ^•d - l yi —STORM— STORM DRAIN onEBY ❑R �� �HH+ RAILROAD TRACKS OUTFACE#1 15o RUBLICR , - UTILITY POLE N76° - -_ -- r - LAMP POSE y� 45' 04 12" I DRAINAGE MANHOLE 1�' •�r _ - - _ _ _ 4 _ _ ' �� INLET r y _ - APPROXIMATE LIMITS • t . -- _ i OF CONCRETE LOAD PIT s O 018 . - ft ' CURBSIDE RECYCLING I W MSW I Z J R p TS } :; I) Q a a re i fey 0 i I - - - BLOCK rL RAiLRORO TRACKS BUILDING m m ylY f fF BUILDING 1 L m - fl I '_� € PREPARED FOR: C- - � 1 ._ I � t I� INERT DEBRIS ! r �- i x I� c::: m �F r r WALL RECYCLING STOCKPILE _ __ _ .- _ r ✓ o rO { �� G) r M 1 BLOCKIMETAL Ft i WALL RECYCLING- GARNER RD, TRANSFER STATION ! MIXED WASTE � at 2610 GARNER RD, fff fj TIPPING PA© BUILDING a RALEIGH NC 0 I A, 1" PHONE: 919£50-6352 I I - y+ I•. PREPARED BY: GATE I I ' `¢ y ¢ t• BLOCK _I { 1 f � BUILDING '00010 _15APPROXIMATE LI� S'� thI j _ NN OF CONCRETE,i�EJYGINEF'RING Ir v RAY HOFFMAN, PE SCALES . .* WALNUT 26677 .`�-. _ - ■y j T. STE PHONE:1704-464-6800 EMAIL RHOFFMAN@HNA-ENGINEERING•COM W i1��+>• �. ~-.x~ha �' ,� ;K ELITE NECO I LLC I 1 ,1 DRAWwcnnE r • Y+ r _ � �►la. DB 17148, PG 2173 EXISTING CONDITIONS -AERIAL ■ i K { w PIN: 1702-87-8749 PROJECT TREE ' �'• '� h . I �r� ,, GARNER RD. TRANSFER STATION PERMIT MODIFICATI( Op 1. tow T •yy .�.i cif � � • 1 � L 1 .- _c r!� JF 1 =CC Y, !ft" T pppp AUGU,T 2022 WALL _GARNRD_TS_EXISTCONW6.4J,DWG NOTES: 1) TOPOGRAPHICAL AND BUILDING INFORMATION PROVIDED BY NEWCOMB LAND SURVEYORS, LLC. SURVEY DATE 1/29/2020-2/19/2020 2) WATERSHED DATA PROVIDED BY NCDENR GIS 3) SURFACE WATER INFORMATION PROVIDED NCDENR GIS 4) AERIAL IMAGERY PROVIDED BY NCONEMAP DATED 2117/2021 - r 1 r �•• ,� � � �' �. t . 6E1' CATE DESCRIPTION CURTIS EQUIPMENT CO. DB 1000, PG 1 PIN: 1702-66-7696 OUTFALL•1 N35' 45' 04,12" APPROXIMATE LIMITS - OF CONCRETE yy�� —. — 1 LOAD PIT / MSW 1 1 TS C/L RAILROAD TRACKS 1 � / 1 / 1 1 INERT DEBRIS f 1 1 STOCKPILE 1 1 7 i 1 If 1 APPROXIMATE LIMITS' OF rCONCRETEmx NOTES 1) TOPOGRAPHICAL AND BUILDING INFORMATION PROVIDED BY NEWCOMB LAND SURVEYORS LLC. SURVEY DATE 1/29/2020 - 2/1912020 2) WATERSHED DATA PROVIDED BY NCDENR GIS 3) SURFACE WATER INFORMATION PROVIDED NCDENR GIS 4) AERIAL IMAGERY PROVIDED BY NCONEMAP DATED 2/17/2021 MIXED WASTE TIPPING PAD JAMES L CLARK DB 8851, PG 2002 BM 1946, PG 31 PIN: 1702-88-9639 ZACHARY A TAYLOR, Ill. DB 16346 PG 854 BM 1982, PG 599 PIN: 1702-96-0639 EBY DRIVE 160' PUBLIC RV) r --_ __-_-- - _Ir CURBSIDE RECYCLING Ln mm BUILDING '` _ L m I 1 BLOCKIMETAL ~/ BUILDING 1 7 BLOCK F BUILDING \ Y ' � SCALES ELITE NEWCO I LLC DB 17148, PG 2173 PIN 1702-87-8749 TAYLOR HOWARD, LLC DB 7456, PG 392 BM 1962, PG 599 PIN 1702-98-2638 GATE — D 80 160 SCALE:1"= 80' LEGEND: — — — — FACILITY BOUNDARY 700— CONTOUR MAJOR CONTOUR MINOR -------- EDGE OF ASPHALT — ------ EDGE OF CONCRETE X FENCE OVERHEAD UTILITY —STORM— STORM DRAIN H{}H}FHiH}}H}H}F RAILROAD TRACKS UTILITY POLE LAMP POSE ® DRAINAGE MANHOLE ® INLET WAL"LR E ClYC L I N I WALL RECYCLING - GARNER RD TRANSFER STATION 2610 GARNER RD. RALEIGH NC PHONE: 919-650-0353 PREPARED BY: �N��NFFRrH� PLLC RAY HOFFMAN, PE 205 WALNUT ST_ STATESVILLE, NC 28677 PHONE: 704-464-6800 EMAIL: RHOFFMAN@HNA-ENGINEERING.COM ORAMNGTITLE EXISTING CONDITIONS PROJECT TITLE 13ARNER RD. TRANSFER STATION PERMIT MODIFICATION JF 1 =80 „-, MIYlI AUGUST M22 WALL GARNRD TS EXISTCOND.(6.4).DWG 3 4 �C l! v11�11i11fI DESCRIPTION I —I CURTIS EQUIPMENT CO. DB 1000, PG 1 PIN: 1702-88-7696 QUTFALL M1 N35" 45'04,12" W78` 38, 01.56" APPROXIMATE LIMITS - OF CONCRETE - i f' C/L RAILROADTPJ r � I r r 1 ♦� k - r •APPROXIMATE LIMITS' - OF CONCRETE NOTES: 1) TOPOGRAPHICAL AND BUILDING INFORMATION PROVIDED BY NEWCOMB LAND SURVEYORS LLC. SURVEY DATE: 1/29/2020 - 2/19/2020 2) WATERSHED DATA PROVIDED BY NCDENR GIS_ 3) SURFACE WATER INFORMATION PROVIDED NCDENR GIS 4) AERIAL IMAGERY PROVIDED BY NCONEMAP DATED 2/1712021 MIXED WASTE TIPPING PAD JAMES L CLARK DB 8851, PG 2002 BM 1946, PG 31 PIN: 1702-88-9639 EBY DRIVE (60' PUBLIC RN•) ZACHARY A. TAYLOR, III. DB 16346, PG 854 BM 1962, PG 599 PIN 1702-98-0639 JPITCURBSIDE RECYCLING f ----------------- --- --- r-- - _� BLOCK m m BUILDING D L: mr I TAYLOR HOWARD, LLC DB 7456 PG 392 BM 1982, PG 599 PIN: 1702-98-2638 II I I 1 1 I I Ix IlI k BLOCK/METAL 'iI BUILDING I4 i � � � M 1 I BLOCK BUILDING SCALES GATE ,S L - - - - - - _- ------�- ELITE NEWCO I LLC DB 17148, PG 2173 PIN 1702-87-8749 0 80 160 SCALEOustom LEGEND: — - - — FACILITY BOUNDARY 700 CONTOUR MAJOR CONTOUR MINOR --------- EDGE OF ASPHALT - - - - - - - • EDGE OF CONCRETE X FENCE OVERHEAD UTILITY —STORM— STORM DRAIN H+H+Fi}Hi}FHi#+HF RAILROAD TRACKS UTILITY POLE LAMP POSE DRAINAGE MANHOLE ® INLET TRAFFIC FLOW: TRANSFER TRUCK TRAFFIC + 0 —.111- LOCAL TRUCK TRAFFIC Q N i0. z I 1 F - D FOR: i WALL RECYCLING JIj1 AL AL f / WALL RECYCLING - GARNER RD_ TRANSFER STATION ay/ 2610 GARNER RD. RAL S9bIGH. NC i FPHONE: 150- 0-8757 J PREPAPED BY HN EIVGlNEERlNG PLlC RAY HOFFMAN, PE 205 WALNUT ST. r STATESVILLE, NC 28677 IJr PHONE: 704-464-6800 EMAIL: RHO FFMAN@HNA-ENGINEERING.COM DPAVJNGTITI,E TRANSFER STATION TRAFFIC FLOW GARNER RO. TRANSFER STATION PERMIT MODIFICATIC J' JF - Cullm • RqW AUGUST 2021 WALL GARNED TS EXISTCONO,(8.4).DWG 4 4 SEAL fl I r rl�• lk :FE� REV DATE DESCRIPTION - xx