Loading...
HomeMy WebLinkAbout0303T_INSP_20220406FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section Page 1 of 4 UNIT TYPE: Lined MSWLF LCID YW Transfer X Compost X SLAS COUNTY: Alleghany Closed MSWLF HHW White goods X Incin T&P FIRM PERMIT NO.: 0303T-TRANSFER-1994 CDLF Tire T&P / Collection X Tire Monofill Industrial Landfill DEMO SDTF FILE TYPE: COMPLIANCE Date of Site Inspection: April 6, 2022 Date of Last Inspection: April 21, 2021 FACILITY NAME AND ADDRESS: Alleghany County Transfer Facility 419 Osbourne Road Sparta, North Carolina 28675 GPS COORDINATES (decimal degrees): Lat.: 36.49343 Long.: -81.14980 FACILITY CONTACT NAME AND PHONE NUMBER: Name: David Spicer, Public Works Director Telephone: (336) 657-0769 Email address: david.spicer@alleghanycounty-nc.gov FACILITY CONTACT ADDRESS: Post Office Box 366 Sparta, North Carolina 28675 PARTICIPANTS: David Spicer, Public Works Director – Alleghany County Andy Harris, Facility Supervisor – Alleghany County Charles Gerstell, NCDEQ – Solid Waste Section STATUS OF PERMIT: A Permit to Operate the Alleghany County Transfer Facility was issued to Alleghany County on October 11, 2019. This permit was for the life-of-site of the facility. PURPOSE OF SITE VISIT: Comprehensive Inspection STATUS OF PAST NOTED VIOLATIONS: N/A OBSERVED VIOLATIONS: None Observed The item(s) listed above were observed by Section staff and require action on behalf of the facility in order to come into or maintain compliance with the Statutes, Rules, and/or other regulatory requirements applicable to this facility. Be advised that pursuant to N.C.G.S. 130A-22, an administrative penalty of up to $15,000 per day may be assessed for each violation of the Solid Waste Laws, Regulations, Conditions of a Permit, or Order under Article 9 of Chapter 130A of the N.C. General Statutes. Further, the facility and/or all responsible parties may also be subject to enforcement actions including penalties, injunction from operation of a solid waste management facility or a solid waste collection service and any such further relief as may be necessary to achieve compliance with the North Carolina Solid Waste Management Act and Rules. FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section Page 2 of 4 ADDITIONAL COMMENTS 1. The facility consists of a transfer facility, a used oil collection area, white goods collection area, tire collection area, metal collection area, and a Small Type-1 Compost Facility. 2. The facility is permitted to receive municipal solid waste generated within areas consistent with the service area of the receiving landfill. Waste must be transported for disposal to an appropriately permitted sanitary landfill. 3. A recycling center is located within a building adjacent to the transfer station. Since the previous inspection, recycling operations have resumed. x Single stream recyclables consisting of paper, plastic, aluminum and metal cans, are collected into an automatic compactor. x Cardboard is collected into an enclosed 40-yard roll-off container. x Recyclables are hauled by County staff to the recycling vendor. x This area was well managed. 4. A gate was located at the entrance to the facility to prevent unauthorized access. 5. The facility had proper signage. Records Review: 6. The Permit and Operations Plan were verified. Both documents were current and available upon request. 7. Tonnage records for July 1, 2021 to April 6, 2022 were submitted to the Solid Waste Section on April 19, 2022 via e-mail. The facility received 9,287.39-tons of waste during this time. 8. Temperature records for compost operations were observed. It appeared that most recent temperatures met requirements. Please ensure all compost achieves 131˚F for three days prior to distribution. 9. Waste screening reports were verified for April 27, 2021 to present. Screenings appeared to have been performed with adequate frequency and provided good documentation of observed unacceptable waste streams and final disposition of those wastes. x New screening frequency requirements effective January 2021 were discussed with facility staff during the inspection. Operations Inspection of the Transfer Station: 10. No unacceptable waste streams were observed. 11. During the inspection, several broken welds were observed in the floor of the transfer station. Mr. Spicer and Mr. Harris explained major repairs and expansion of the tipping floor and transfer station building are planned to start in the fall of the year. Repairs will include replacement of the steel floor with concrete and adding a 30-foot covered expansion to the tipping floor. 12. The facility walls were in need of pressure washing. The new Administrative Rule requirement regarding pressure washing requirements were discussed with facility staff. 13. Windblown waste was well managed. 14. A small amount of waste was observed on the floor of the transfer trailer loading bay. Waste is removed from the floor of the bay throughout the day. This area was well managed at the time of the inspection. 15. Leachate drains within the floor of the transfer trailer loading bay could not be observed during the inspection due to a trailer being located within the bay. However, there was no evidence observed indicating that the drains were not functioning properly. Operations Inspection of the White Goods Area: 16. White goods are collected on a covered concrete pad south of the transfer station building. 17. All white goods were observed standing in an upright condition at the time of inspection. 18. No food wastes were observed on the concrete pad. 19. This area was well managed. FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section Page 3 of 4 Operations Inspection of the Scrap Tire Collection Area: 20. Scrap tires were being collected into a covered trailer southeast of the transfer facility building. 21. All tires were maintained within the designated trailer at the time of the inspection. 22. This area was well managed. Operations Inspection of the Type-1 Compost Area: 23. No active composting was occurring on site at the time of inspection as material had yet to be ground. 24. A thorough inspection of this area could not be made due to wet conditions. 25. Please continue to ensure the stockpile of unground material does not encroach on the footprint of the closed landfill. Supporting Comments: 26. A 500-gallon above ground storage tank is provided adjacent to the entrance to the transfer facility building for collection of used oil. A fuel tank is located adjacent to the used oil tank. x Since the last inspection, a concrete secondary containment device has been installed around the subject tanks. x Mr. Spicer and Mr. Harris explained a roof will be constructed over the secondary containment device in the near future. 27. Used pesticide containers are collected into a covered trailer adjacent to the trailer designated for collection of used tires. All containers were maintained within the designated trailer at the time of inspection. 28. A beneficial fill area is located west of the transfer facility building. During the inspection, multiple pieces of rebar were observed protruding from pieces of concrete on site. Rebar should be cut flush with the surface of concrete in order to encase the metal within the concrete. x Multiple pieces of fabric were observed within the fill area. This appeared to be erosion control fabric. A single playing card and a piece of cardboard were also observed. This material does not meet the definition of beneficial fill and must be removed. x As noted on the previous inspection report, it is recommended that signs be installed informing the public what types of material are acceptable for fill in this area. 29. As previously noted, major construction activities to improve the condition of the transfer station building are planned to commence in the fall of the year. An Assessment Repair Request Response was issued by the Solid Waste Section on March 21, 2022. x Facility improvements include extending the transfer station building 30-feet to the north, replacing the tipping floor and adding new push walls, installing chutes at the tipping floor edge to direct waste into the trailer and replacing the inoperable rollup doors. x To facilitate the work, plans are to improve the loading dock to the south of the transfer station building for the temporary management of solid waste. These improvements include replacing the concrete pad and adding a leachate collection drain with a storage tank, the construction of block push walls along two sides of the concrete pad and the installation of fencing to minimize windblown waste. x The March 21, 2022 letter from the Solid Waste Section authorized the improvements for the loading dock necessary for the temporary management of solid waste given certain conditions outlined in the letter. Repairs for the existing transfer station building will be authorized in the future under separate cover. FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section Page 4 of 4 Please contact me if you have any questions or concerns regarding this inspection report. ________________________________________ Phone: (704) 235-2144 Charles T. Gerstell Environmental Senior Specialist Regional Representative Sent on: 4/20/22 X Email Hand delivery US Mail Certified No. [ _] Copies: Deb Aja, Western District Supervisor - Solid Waste Section Digitally signed by Charles T. Gerstell DN: cn=Charles T. Gerstell, o=Divsion of Waste Management, ou=Solid Waste Section, email=charles.gerstell@ncdenr.gov, c=US Date: 2022.04.20 11:32:30 -04'00'