Loading...
HomeMy WebLinkAbout6013_Mecklenburg_NorthMeck_GreenwayWaste_CDLF_Infill_PhaseI_Dec21LFG_FID1636415_20220111Yes / No "v "111.1 Environmental Monitoring Division of Waste Management - Solid Waste Reporting Form Notice: This form and any information attached to it are Public Records" as defined in NC General Statute 132-1, As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Instructions: • Prepare one form for each individually monitored unit. Please type or print legibly. Attach a notification table with values that attain or exceed NC 2L groundwater standards or NC 2B surface water standards. The notification must include a preliminary analysis of the cause and significance of each value. (e.g. naturally occurring, off -site source, pre-existing condition, etc.). • Attach a notification table of any groundwater or surface water values that equal or exceed the reporting limits. Attach a notification table of any methane gas values that attain or exceed explosive gas levels. This includes any structures on or nearby the facility (NCAC 13B .1629 (4)(a)(i). • Send the original signed and sealed form, any tables, and Electronic Data Deliverable to: Compliance Unit, NCDENR-DWM, Solid Waste Section, 1646 Mail Service Center, Raleigh, NC 27699-1646. Solid Waste Monitoring Data Submittal Information Name of entity submitting data (laboratory, consultant, facility owner): Greenway Waste Solutions at North Meck, LLC Contact for questions about data formatting. Include data preparer's name, telephone number and E-mail address: Name: Brandt Kayser, P.G. Phone: 914-844-7048 E-mail: brandt@griffinbros.com NC Landfill Rule: Actual sampling dates (e.g., Facility name: Facility Address: Facility Permit # (.0500 or .1600) Ortnhpr 90aa ?nna) WasteSolutions at North L 15300 Holbrooks Rd, Huntersville, NC ecember 21 8 28, 2021 (Infill Side) 28078 Environmental Status: (Check all that apply) El Initial/Background Monitoring Detection Monitoring e of data submitted: (Check all that apply) Groundwater monitoring data from monitoring wells Groundwater monitoring data from private water supply wells Leachate monitoring data Surface water monitoring data QX Assessment Monitoring QX Methane gas monitoring data Corrective action data (specify) ❑ Other(specify) Corrective Action Notification attached? 8 No. No groundwater or surface water standards were exceeded. Yes, a notification of values exceeding a groundwater or surface water standard is attached. It includes a list of groundwater and surface water monitoring points, dates, analytical values, NC 2L groundwater standard, NC 2B surface water standard or NC Solid Waste GWPS and preliminary analysis of the cause and significance of any concentration. QX Yes, a notification of values exceeding an explosive methane gas limit is attached. It includes the methane monitoring points, dates, sample values and explosive methane gas limits. i o me nest or my Knowledge, the information reported and statements made on this data submittal and attachments are true and correct. Furthermore, I have attached complete notification of any sampling values meeting or exceeding groundwater standards or explosive gas levels, and a preliminary analysis of the cause and significance of concentrations exceeding groundwater standards. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. Brandt Kayser, P.G. Environmental Compliance Officer 914-844-7048 Facility Represent rve Name (Print)^ Title (Area Code) Telephone Number �.c/ 1 1/11/2022 Affix NC Licensg0APf6ftls6ig9pl Geologist Seal Signature Date .e4s@' Ft' C•A(°°"Os 19505 Liverpool Pkwy, Huntersville, NC 28031F";' `� •'•:`� Facility Representative Address Z_ NA NC PE Firm License Number (if applicable effective May 1, 2009) w�,,•'••, � C l.} 0 Landfill Name: Sampler Name: Barometric Pressure Temperature: Weather Conditions Instrument: Date: METHANE MONITORING FORM Greenway Waste Solutions at North Meek C&D Landfill - Infill Brandt Kayser, P.G. 29.09 in Hg 40° F Overcast, breezy Landtec GEM 5000/G506613 December 21, 2021 Location Time CH4 CH4 LEL 02 CO2 MMW-1 1245 0.0 0.0 14.3 4.8 MMW-2 1250 0.1 2 12.4 6.1 MMW-3 1255 16.4 328 1.7 27.4 MMW-4 1310 0.0 0.0 17.1 2.0 MMW-5 1315 0.0 0.0 18.4 0.8 MMW-6 1325 0.0 0.0 14.9 4.7 MMW-7 1330 0.0 0.0 16.3 5.7 MMW-8 1335 0.0 0.0 19.0 1.3 MMW-9 1455 0.0 0.0 17.5 7.0 MMW-10 1505 0.0 0.0 1.9 21.3 MMW-11 1515 1.5 30 18.0 2.5 Scale House 1515 0.0 0.0 20.2 0.2 MRF Break Room 1525 0.0 0.0 20.2 0.1 Barometric Pressure Temperature: Weather Conditions Instrument: Date: 29.12 in Hg 38° F Clear, breezy Landtec GEM 5000/G506613 December 28, 2021 Location Time CH4 CH4 LEL 02 CO2 MMW-3 1015 7.7 154 12.3 5.0 MMW-11 1025 0.2 4 14.4 4.2 Comments: CH4 LEL is a calculated value based on 5% CH4 = 100% CH4 LEL NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: This jornr and amin formation attached a it are "Public Records"as defined in NC General Stature 132-1. As such, these documents m'e available fmYnspection and examination by am person upon request (NC Gene? at Statute 132-6). Facility Name: ``North Meek Landfill - Infill Side Permit Number: Sampling Date:l�wtltd 1 NC Landfill Rule (.0500 or.1600): _ 60-13 .0500 Sample Collector Name & Position: Brandt Kayser / Environmental Compliance Officer Gas Meter Type & Serial Number: Landtec GEM 5000 Plus - G506613 Gas Meter Calibration Date: 9/9/2021 Field Calibration Date & Time: /W)I�dI o i f Field Calibration Gas Type (15115 or 35/50): 35/50 Field Calibration Gas Canister Expiration Date: 4/2/22 Gas Meter Pump Rate: C40,-,4 j1a*rli Ambient Air Temperatuve:Y&P Barometric Pressure (9or man Hg): as 6g Weather Conditions: Instructions: Under "Location or LEG Well", list monitoring well it or describe monitoring location (e.g., inside field office). Attach a test location may or drawing. Report methane readings as both % LEL and % CH4 by volume. Convert % CHa (by volume) to % LEL as follows: % methane (by volume)/20 = %LEL. *Hydrogen Sulfide (H2S) gas monitoring may be required for Construction & Demolition Landfills (CDLFs). See individual permit conditions andtor Facility LFG monitoring plan. Location or LFG Well ID Sample Tube Purge Time of Day Time Pumped (am) Initial %LEL Stabilized %LEL %CH4 (volume) %02 (volume) %CO2 (volume) %H2S' (yaluax) 9 NOTES MMW-1 0 6C) '— — 0 (4-3 '4-),I Cj CO:0 MMW-2 !.)J'-!i vZ 0, ,tj (a, I ( CO: Q. MMW-3 (.�,1 ,.3� .3,�J' (v,C% (t -1,9 CO: ' MMW-4 (3 .o ,_ -- L%. L) l7' 2,0 ` CO: MMW-5 S/ — .— _. 0 , tt G}. / © 0..`0 w. CO: 4pj MMW-6 0.0 9.q q. 0 CO: O nc,.� MMW-7 �..3� '— — 0, ) 16,3 1 7 3 CO: MMW-8 ! 33J — —o Qf I R 1„3 3 CO: MMW-9 0,0 1 -7, H %, 0 C) CO: MMW-10 (J�Uj -- — e- t,t - 3 0� CO: MMW-11 f �I� n .L7 d, f V CO: ('j w Scale House 2 0 CC:Q NOTE: Orneeded, anach additional data forms to include additional LFG monitoring data locations far the facili0. ACTION Lr; fi_s: Methane: >I.25%by volume (inside structures) AND >5"/o by volume (at facility boundary) Hydrogen Sulfide: > 1 % by volume (inside structures) AND >4% by volume (at facility boundary) Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. 1 am aware that there are significant penalties for making any false statement, representation, or certificationyncluding the possibility of a fine and imprisonment. 'i/ SIGNATURE TITLE Revised - March 6, 2017 NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: This forty and any infornuaion attached to a are 'Public Records" as defined in NC Genera( Statute 132-1. ,4s such, these documents are available, for inspection and examination by any person upon request (NC General Statute 132-6). Facility Name: North Meek Landfill - Infill Side Permit Number: Sampling Date:.. l NC Landfill Rule (.0500 or.] 600): _ Sample Collector Name & Position: Brandt Kayser / Environmental Compliance Officer 60-13 .0500 Gas Meter Type & Serial Number: Landtec GEM 5000 Plus - G506613 Gas Meter Calibration Date: 9/9/2021 Field Calibration Date & Time: _IXJ0 1 Field Calibration Gas Type (15115 or 35/50): 35/50 Field Calibration Gas Canister Expiration Date: 4/2/22 Gas Meter Pump Rate: tL orl., 3 /z. t1 Ambient Air Temperature: ) Tr- Barometric Pressure l`� or mm flg):a� 1) Weather Conditions: C Ck9. 4 q Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office). Attach a test location man or drawing. Report methane readings as both % LEL and % CH4 by volume. Convert %CH4 (by volume) to % LEL as follows: % methane (by voluirl = % LEL. *Hydrogen Sulfide (H2S) gas monitoring may be required for Construction & Demolition Landfills (CDLFs). See individual permit conditions and/or Facility LFG monitoring plan. Location or LFG Well ID Sample Tube Purge Time of f Day Time P (see) Initial %LEL Stabilized %LEL %CH4 (volume) %02 (volume) %CO2 (volume) %H2S* (volume) NOTES MMW-3 MMW-11 ,0J� >� CUis ((Ji 1 C,0 tie- ti— (J `•i 7-2 Lz p,J 9 r,0 c/. ,L i CO: ('.w. CO: (ana. [10 7- .. ............ ...b .. �., �..,.��.o ,.,�u. � .e�ui ...y. ACTION LEVELS: Methane: >I.25% by volume (inside structures) AND >5% by volume (at facility boundary) Hydrogen Sulfide: >I % by volume (inside structures) AND >4% by volume (at facility boundary) Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. 1 am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. t c)P . SIGNATURE TITLE Ravicad — Ma,,h A ?ni 7 *, ;, �, � �� ���• * .f •�l •� � , ', �_ LEGEND PROPERTY LINE �� �.. �•• ,'� EXISTING STREAM +- s � _ CLOSED PHASE I AREA METHANE NORTH !� t MONITORING WELL • :�� INFILL AREA +�n METHANE MONITORING WELL ' � '� LANDFILL POINT OF COMPLIANCE - Mw-4a GROUNDWATER MONITORING WELL ,. MW-5 LANDFILL REVIEW BOUNDARY • GROUNDWATER MONITORING WELL SURFACE WATER SAMPLING = sw-� LOCATION (D sw-7 NEW SURFACE WATER SAMPLING � + LOCATION (APPROX) (i) REFERENCE TO INFILL AREA yR' ' i o*- t f i . T +. d ; + - + ' MW-9D(i) 1 y F ■ *. x `4 . ` + 4y ' • Y� S't w FCLOSED PHASE I AREA MW-6Dl-- MW-9 - .D :� 1 ` �.. • ' t [1i i i GREENWAY WASTE SOLUTIONS OF A AV AV NORTH MECK, LCC Civil & Environmental Consultants, Inc. NORTH MECKLENBURG LANDFILL 1900 Center Park Drive - Suite A - Charlotte, NC 28217 HUNTERSVILLE, NORTH CAROLINA REFERENCE Ph: 980.237.0373 - Fax: 980.237.0372 WATER QUALITY MONITORING LOCATION MAP SCALE IN FEET www.cecinc.com 1. AERIAL IMAGERY TAKEN FROM GOOGLE EARTH PRO. DRAWN BY: JKS/PAB CHECKED BY: EHS APPROVED BY: EHS ATTACHMENT: DATED OCTOBER 8, 2016 0 400 800 DATE: FEBRUARY 2018 1 DWG SCALE: 1" = 400' PROJECT NO: 111-370.0001 1 Vrr,r, ReportinForm Division of Waste Management -Solid Waste tlt Notice. This form and any informatlon attached to it are Public Records as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Instructions: • Prepare one form for each individually monitored unit. • Please type or print legibly. • Attach a notification table with values that attain or exceed NC 2L groundwater standards or NC 2B surface water standards. The notification must include a preliminary analysis of the cause and significance of each value. (e.g. naturally occurring, off -site source, pre-existing condition, etc.). • Attach a notification table of any groundwater or surface water values that equal or exceed the reporting limits. • Attach a notification table of any methane gas values that attain or exceed explosive gas levels. This includes any structures on or nearby the facility (NCAC 13B .1629 (4)(a)(i). Send the original signed and sealed form, any tables, and Electronic Data Deliverable to: Compliance Unit, NCDENR-DWM, Solid Waste Section, 1646 Mail Service Center, Raleigh, NC 27699-1646. data (laboratory, consultant, facility owner): Greenway Waste Solutions at North Meck, LLC Contact for questions about data formatting. Include data preparer's name, telephone number and E-mail address: Name: Brandt Kayser, P.G. Phone: 914-844-7048 E-mail: brandt@griffinbros.com NC Landfill Rule: Actual sampling dates (e.g., Facility name: Facility Address: Facility Permit # (.0500 or .1600) October 20-24 2006 reenway Waste Solutions at North 15300 Holbrooks Rd, Huntersville, NC 60-13 ecember 21, 2021 eck, LLC (Closed Side) 28078 .0500 Environmental Status: (Check all that apply) Initial/Background Monitoring Detection Monitoring Q Assessment Monitoring Corrective Action of data submitted: (Check all that apply) Groundwater monitoring data from monitoring wells Q Methane gas monitoring data Groundwater monitoring data from private water supply wells Corrective action data (specify) Leachate monitoring data Surface water monitoring data Other(specify) Notification attached? 8 No. No groundwater or surface water standards were exceeded. Yes, a notification of values exceeding a groundwater or surface water standard is attached. It includes a list of groundwater and surface water monitoring points, dates, analytical values, NC 2L groundwater standard, NC 2B surface water standard or NC Solid Waste GWPS and preliminary analysis of the cause and significance of any concentration. Yes, a notification of values exceeding an explosive methane gas limit is attached. It includes the methane monitoring points, dates, sample values and explosive methane gas limits. ....,,c ..ca. �, my nuvmcayc, "nc rnwnvauon reportea ano swrements maae on this data submittal and attachments are true and correct. Furthermore, I have attached complete notification of any sampling values meeting or exceeding groundwater standards or explosive gas levels, and a preliminary analysis of the cause and significance of concentrations exceeding groundwater standards. 1 am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. Brandt Kayser, P.G. Environmental Compliance Officer 914-844-7048 Facility Repre�tive Name (Print) Title (Area Code) Telephone Number 1111 /2022 Date 19505 Liverpool Pkwy, Huntersville, NC 28031 Facility Representative Address Affix NC Liicegsb°�'�)l?i`ofes`Skl Geologist Seal fy or NA NG PE Firm License Number (if applicable effective May 11 2009) )11ttivd— METHANE MONITORING FORM Landfill Name: Greenway Waste Solutions at North Meck C&D Landfill - Closed Sampler Name: Brandt Kayser, P.G. Barometric Pressure: 29.09 in Hg Temperature: 40° F Weather Conditions: Overcast, breezy Instrument: Landtec GEM 5000/G506613 Date: December 21, 2021 Location Time CH4 CH4 LEL Oz COz GW-1 1345 0.0 0.0 15.7 5.6 GW-2 1350 0.0 0.0 18.9 1.0 GW-3 1355 0.0 0.0 16.2 3.4 GW-4 1400 0.0 0.0 14.4 7.6 GW-5 1405 0.0 0.0 16.9 4.0 GW-6 1410 0.0 0.0 17.2 3.6 GW-7 1430 0.0 0.0 13.6 5.6 GW-8 1435 0.0 0.0 16.4 3.2 GW-9 1440 0.0 0.0 17.8 2.2 GW-10 1445 0.0 0.0 13.1 6.1 Barn 1415 0.0 0.0 20.3 0.2 Comments: CH4 LEL is a calculated value based on 5% CH4 = 100% CH4 LEL NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: This forni and any it fmnmrion attached to it are Tubhc Records"as defined in NC General Statute 132-1. As such, these docunretes are mailable for inspeclion and examination bi anal person upon request (NC General Slanne 132-6), Facility Name: North Meek Landfill - Closed Side Number: Sampling Date: lALmQl NC Landfill Rule (.0500 or. 1600): 60-13 .0500 Sample Collector Name & Position: Brandt Kayser / Environmental Compliance Officer Gas Meter Type & Serial Number: Landtec GEM 5000 Plus - G506613 Gas Meter Calibration Date: 9/9/2021 Field Calibration Date & Time: (d( )I A)1 1.Zl,r Field Calibration Gas Type (15/15 or 35/50): 35/50 Field Calibration Gas Canister Expiration Dale: 4/2/22 Gas Meter Pump Rate:U Ambient Air Temperature: t"— Barometric Pressure (Sp br man Hg):� q- 0' Weather Conditions: Instructions: Under "Location or LEG Well", list monitoring well # or describe monitoring location (e.g., inside field office). Attach a test location map or drawing. Report methane readings as both % LEL and % CH4 by volume. Convert % CHa (by volume) to % LEL as follows: % methane (by volume)/20 = % LEL. `Hydrogen Sulfide (H2S) gas monitoring may be required for Construction & Demolition Landfills (CDLFs). See individual permit conditions and/or Facility LFG monitoring plan. Location or LEG Well ID Sample Tube Purge Time of Day I Time Pumped (see) Initial %LEL Stabilized %LEL %CH4 (volume) %02 (volume) %CO2 (volume) %H2S• NOTES GW-I 30 .Yrz 13 5� 0 "' — 0`� I J, f�.� C� CO:O i15L) — — et—) lu,zGw-2 l,oC� CO: 414 GW-3 l 31J.1— — — 03 0 [ Ir.;>? 3.(+- CO: GW-4 I Itti0 — 0,0 1 ltl.q 71(r, 1 CO:� GW-5 I y0} 0. 6) wq 4 :Gl 0 CO:f rn GW-6 It t/-%(I '— -- (?..L) j % 3, C, 6 CO:(? GW-7 %3Li — 010 0-. & S.(1 I CO: b, 3,+-. GW-s a L) (ot 51 3. co: 6),� GW-9 1y4C — — 0,0 17, L l CO: 0, GW-10 I V-t, — '— 0, r/ ( (p: 1 l CO:1 Barn 4 i 3 ' 0 -6) aGl. ) 6.) 0 CO: C) WhKr,-% NOTE: ljneeded, attach additional data forms to include additional LEG monitoring data locations jar the facility. I ACTION LEVELS: Methane: >L25%by volume (inside structures)AND>5% by volume (at facility boundary) Hydrogen Sulfide: >I%by volume (inside structures) AND >4%by volume (at facility boundary) Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there are significant penalties for making any false statement, representation, or certification ijuaWing the possibility of a fine and imprisonment. Environmental Compliance Officer SIGNATURE TITLE Revised -March 6, 2017 *, ;, �, � �� ���• * .f •�l •� � , ', �_ LEGEND PROPERTY LINE �� �.. �•• ,'� EXISTING STREAM +- s � _ CLOSED PHASE I AREA METHANE NORTH !� t MONITORING WELL • :�� INFILL AREA +�n METHANE MONITORING WELL ' � '� LANDFILL POINT OF COMPLIANCE - Mw-4a GROUNDWATER MONITORING WELL ,. MW-5 LANDFILL REVIEW BOUNDARY • GROUNDWATER MONITORING WELL SURFACE WATER SAMPLING = sw-� LOCATION (D sw-7 NEW SURFACE WATER SAMPLING � + LOCATION (APPROX) (i) REFERENCE TO INFILL AREA yR' ' i o*- t f i . T +. d ; + - + ' MW-9D(i) 1 y F ■ *. x `4 . ` + 4y ' • Y� S't w FCLOSED PHASE I AREA MW-6Dl-- MW-9 - .D :� 1 ` �.. • ' t [1i i i GREENWAY WASTE SOLUTIONS OF A AV AV NORTH MECK, LCC Civil & Environmental Consultants, Inc. NORTH MECKLENBURG LANDFILL 1900 Center Park Drive - Suite A - Charlotte, NC 28217 HUNTERSVILLE, NORTH CAROLINA REFERENCE Ph: 980.237.0373 - Fax: 980.237.0372 WATER QUALITY MONITORING LOCATION MAP SCALE IN FEET www.cecinc.com 1. AERIAL IMAGERY TAKEN FROM GOOGLE EARTH PRO. DRAWN BY: JKS/PAB CHECKED BY: EHS APPROVED BY: EHS ATTACHMENT: DATED OCTOBER 8, 2016 0 400 800 DATE: FEBRUARY 2018 1 DWG SCALE: 1" = 400' PROJECT NO: 111-370.0001 1