Loading...
HomeMy WebLinkAbout1812_DukeMarshall_PiezometerRecords_CLF21-13_13R_FID1624358_20211115(> DUKE ENERGY November 15, 2021 North Carolina Department of Environmental Quality Division of Waste Management Solid Waste Section 1646 Mail Service Center Raleigh, North Carolina 28778 Attn: Ms. Sarah Moutos (submitted electronically) Re: Piezometer CLF21-13 and CLF21-13R Records Submittal Industrial Landfill No.1, Phase 2 Permit No. 1812-INDUS-2008 Marshall Steam Station Terrell, North Carolina 28682 Dear Ms. Moutos: 526 South Church St. Charlotte, NC 28202 Mailing Address P.O. Box 1006 Mail Code EC 13K. Charlotte, NC 28201-1006 717-982-0986 The Solid Waste Section approved Duke Energy's request for replacing one damaged piezometers (CLF21-13) with a new piezometer (CLF21-13R) at the perimeter of Cell 5 for the Industrial Landfill No.1 (1812-INDUS-2008) Phase 2 expansion in letter dated October 27, 2021. The piezometer was installed to support collection of groundwater data. Duke Energy is providing the boring log, well construction record, and well abandonment record for the piezometer replacement. The piezometer installation and abandonment was conducted by S&ME on November 4, 2021. These records were submitted separately to the NCDEQ Information Processing Unit. If you have any questions or concerns, please do not hesitate to contact me at Ashlev.Albert(H�duke-energy.com or (717) 982-0986. Respectfully JJsubmitted, J /t� Ashley Albert, P.G. Environmental Services Attachments: Well Construction and Well Abandonment Records (GW-1 and GW-30 Forms) (S&ME, November 2021) cc (via e-mail): Ben Jackson, NCDEQ Sherri Stanley, NCDEQ Ed Mussler, NCDEQ Julie Roberston, S&ME Kyle Baucom, Duke Energy Chris Varner, Duke Energy James Malloy, Duke Energy Ryan Czop, Duke Energy www.duke-energy.com Page 1 of 1 s II� November 11, 2021 North Carolina Department of Environmental Quality Division of Water Resources — Information Processing Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617 Attention: Information Processing Unit Reference: Well Construction and Well Abandonment Records (GW-1 and GW-30 Forms) Duke Energy — Marshall Steam Station Abandonment and Replacement of Damaged Well CLF21-13 S&ME Project No. 212013, Ph. 101 Information Processing Unit: S&ME, Inc. (S&ME) is submitting the enclosed completed and signed Well Construction Record associated with the installation of well CLF21-13R (installed to replace damaged well CLF21-13), as well a boring log and well construction diagram. A completed and signed Well Abandonment Record for the abandonment of damaged well CLF21-13 is enclosed as well. A North Carolina registered well driller installed well CLF21-13R on November 4, 2021 in accordance with 15A NCAC 02C Standards. Well development was subsequently performed on November 5, 2021, meeting Duke Energy's criteria of groundwater turbidity lower than 50 NTUs. CLF21-13 was abandoned by a North Carolina registered well driller on November 5, 2021 in accordance with 15A NCAC 02C Standards and Duke Energy's Guidance for Well Abandonments in North Carolina (EHS Work Standard, Revision 1). S&ME thanks you for your receipt of these records. Should you have any questions or need additional information, please do not hesitate to contact us at (704) 523-4726. Respectfully Submitted, S&ME, Inc. VALKV-et P Jasmine Tayouga Michael T. Romanello, PE Associate Project Manager Project Manager S&ME, Inc. 12016 Ayrsley Town Blvd., Suite 2-A I Charlotte, NC 282731 p 704.523.4726 1 www.smeinc.com Duke Energy — Marshall Steam Station Division of Water Resources — Information Processing Unit r9jF�u ollP.3.:Y4ttizF;^;e r'de,A Senior Reviewed By: s Julie P. Robertson, P.G. (Registration No. 1995) y '' r <q C. e "7p':S7 i¢L9:a November 11, 2021 Page 2 Enclosures: One (1) GW-1 Form, CLF21-13R Boring Log and Well Construction Diagram, one (1) GW-30 Form cc: Ashley Albert, EHS Waste and Groundwater Programs, Duke Energy S&ME, Inc. WELL ABANDONMENT RECORD 1. Well Contractor Information: Justin Marlowe Well Contractor Name (or well owner personally abandoning well on his/her property) 4452-A NC Well Contractor Certification Number S&ME, Inc. Company Name 2. Well Construction Permit #: Not Applicable List all applicable well construction permits fl e. VIC, County, State, Variance, etc.) if/rnown 3. Well use (check well use): Water Supply Well: ❑Agricultural ❑Geothermal (Heating/Cooling Supply) ❑ Industrial/Commercial Non -Water Supply Well: ❑Municipal/Public ❑Residential Water Supply (single) ❑Residential Water Supply (shared) Injection Well: ❑Aquifer Recharge ❑Groundwater Remediation ❑Aquifer Storage and Recovery ❑Salinity Barrier ❑Aquifer Test ❑Stormwater Drainage ❑Experimental Technology ❑Subsidence Control ❑Geothermal (Closed Loop) ❑Tracer ❑Geothermal (Heatim Cooling Return) ❑Other (explain under 7 ; } 4. Date well(s) abandoned: 11 /5/2021 5a. Well location: Duke Energy Not Applicable Facility/Owner Name Facility ID# (if applicable) 8320 E NC 150 Hwy., Terrell, North Carolina 28682 Physical Address, City, and Zip Catawba County 461803426350 Parcel Identification No. (PIN) 5b. Latitude and longitude in degrees/minutes/seconds or decimal degrees: (ifwell field, one lat/long is sufficient) 35-619041 N-80.976034 W CONSTRUCTION DETAILS OF WEL S BEING ABANDONED Attach well construction record(s) ifavailable. For multiple injection ornon-watersupply wells ONLY with the same construction/abandonment, you can submit one form. 6a. Well ID#: CLF21-13 6b. Total well depth: 35.1 6c. Borehole diameter: 8 (in.) 6d. Water level below ground surface: 17.0 (ft.) For Internal Use ONLY: WELL ABANDONMENT DETAILS 7a. For Geoprobe/DPT or Closed -Loop Geothermal Wells having the same well construction/depth, only 1 GW-30 is needed. Indicate TOTAL NUMBER of wells abandoned: 7b. Approximate volume of water remaining in well(s): 3.0 FOR WATER SUPPLY WELLS ONLY: 7c. Type of disinfectant used: 7d. Amount of disinfectant used: 7e. Sealing materials used (check all that apply): ❑ Neat Cement Grout ❑ Bentonite Clips or Pellets ❑ Sand Cement Grout ❑ Dry Clay ❑ Concrete Grout ❑ Drill Cuttings ❑ Specialty Grout ❑ Gravel Ft Bentonite Slurry ❑ Other (explain under 7g) 7£ For each material selected above, provide amount of materials used: Bentonite slurry mix - 8 lbs. Water - 4 gal. 7g. Provide a brief description of the abandonment procedure - The bentonite slurry mix consisted of 4 gallons of water and 8 pounds of Quik-Grout (sodium bentonite-based grout). This mix was pumped into the botton of the well using 1 inch tremie pipe. 8. Certification: S' of Certified Well Contractor or Well owned Date By signing this form, I hereby certify that the well(s) was (were) abandoned in accordance with 15A NCAC 02C .0100 or 2C .0200 Well Construction Standards and that a copy of this record has been provided to the well owner. 9. Site diagram or additional well details: You may use the back of this page to provide additional well site details or well abandonment details. You may also attach additional pages if necessary. SUBMITTAL INSTRUCTIONS 10a. For All Wells: Submit this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Information Processing Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 10b. For Injection Wells: In addition to sending the form to the address in 10a above, also submit one copy of this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Underground Injection Control Program, 1636 Mail Service Center, Raleigh, NC 27699-1636 6e. Outer casing length (ff known): NA 00 10c. For Water Supply & Infection Wells: In addition to sending the form to the address(es) above, also submit one copy of this form within 30 days of completion of well abandonment to the county health department of the county where 6L Inner casing/tubing length (if known): 25.0 (ft.) abandoned. 6g. Screen length (if known): 10.0 (ft.) Form GW-30 North Carolina Department of Environmental Quality - Division of Water Resources Revised 2-22-2016 Print Form WELL CONSTRUCTION RECORD fGW-1) For internal Use Only: 1. Well Contractor Information: Justin Marlowe Well Contractor Name 4452-A NC Well Contractor Certification Number SWE, Inc. Company Name 2. Well Construction Permit #: Not applicable List all applicable well construction permits (i.e. UIC, Cotmry, State, Variance, etc.) 3. Well Use (check well use): Well: (Heating/Cooling Supply) Recharge Storage and Recovery Test rental Technology oral (Closed Loop) 4. Date Well(s) Completed: 11 /5/2021 ®MunicipaUPublic Residential Water Supply (single) Residential Water Supply (shared) Groundwater Remediation ®Salinity Barrier ®Storrwater Drainage ®Subsidence Control Tracer under #21 Remarks Well aw CLF21-13R 5a. Well Location: Duke Energy Not Applicable Facility/Owner Name Facility ID# (if applicable) 8320 E NC 150 Hwy., Terrell, North Carolina 28682 Physical Address, City, and Zip Catawba County 461803426350 Parcel Identification No. (PIN) 5b. Latitude and longitude in degrees/minutes/seconds or decimal degrees: (if well field, one lat/long is sufficient) 35.619019 N-80.976044 W 6. Is(are) the well(s)oPermanent or InTemporary 7. Is this a repair to an existing well: [3Yes or MNo If this is a repair, fill out known well construction information and explain the nature of the repair under #21 remarks section or on the back of this form. 8. For Geoprobe/DPT or Closed -Loop Geothermal Wells having the same construction, only I GW-1 is needed. Indicate TOTAL NUMBER of wells drill A• NIA 9. Total well depth below land surface: 35.3 For multiple wells list all depths ifdii ferent (example- 3@200' and 2@100') 10. Static water level below top of casing: If water level is above casing, use 11. Borehole diameter: 7.5 (in.) 3 25" Hollow Stem Au arc 17 12. Well construction method: to (i.e, auger, rotary, cable, direct push, etc.) 14. WATER ZONES FROM - TO DESCRIPTION ft. ft. tt. ft. 15. OUTER CASING for mold -cued wens OR LINER (lr ¢ licable FROM TO DIAMETER THICKNESS MAr'F:R[AI. ft. j ft. Ia IC INNER CASING OR Ti1DING eotherotal closed -loom FROM TO DIAMETER THICKNESS MATERIAL 0 ft. 25 ft. 2 i.. sch. 4o Pvc n. It. ht 17. SCREEN FROM TO DIAMETER SEAT SIZE THICKNESS MATERIAL 25 ft• 35 fL 2.0 in. 0.010 Seh.40 Pvc ft. ft. In. 19. GROUT FROM TO MATERIAL EMPLACEMENT METHOD 6 AMOUNT 0 ft. 17.7 fL neat cement Tremie pipe; -42 gals ri. ft. 19. SAND/GRAVEL PACK (if a licahle FROM TO MATERIAL EMPLACEMENT METHOD 22 ft. 37 ft- #2fitter sand Pour ft. ft. 20. DRILLING LOG attach additional sheets If necessa FROM TO DESCRIPTION tcalor harafem wWraek tv e. gr.la etu. etc. o ft 10 ft• Reddish -brown, tight brown, fine sand with silt 10 ft 15 ft• Reddish -brown, fine, silty sand 15 ft 35 ft. Reddish -brown, fine, sandy silt ft. ft. ft. ft. ft. ft. ft. ft. 21. REMARKS 22. Certification: Si re of Certified Well Contractor Date signing this form, I hereby certify that the well(s) was (were) constructed in accordance with 15A NCAC 02C .0100 or ISA NCAC 02C .0200 Well Construction Standards and that a copy of this record has been provided to the well owwer. 23. Site diagram or additional well details: You may use the back of this page to provide additional well site details or well construction details. You may also attach additional pages if necessary. SUBMITTAL INSTRUCTIONS 00 24a. For All Wells: Submit this form within 30 days of completion of well construction to the following: (ft.) Division of Water Resources, Information Processing Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 24b. For Injection Wells: In addition to sending the form to the address in 24a above, also submit one copy of this fort within 30 days of completion of well construction to the following: Division of Water Resources, Underground Injection Control Program, FOR WATER SUPPLY WELLS ONLY: 1636 Mail Service Center, Raleigh, NC 27699-1636 13a. Yield (gpm) Method of test: 24c. For Water Sunnly & Infection Wells: In addition to sending the form to the address(es) above, also submit one copy of this form within 30 days of 13b. Disinfection type: Amount: completion of well construction to the county health department of the county where constructed. Form GW-1 North Carolina Department of Environmental Quality - Division of Water Resources Revised 2-22-2016 PROJECT: Marshall Steam Station CLF21-13R Well Installation Terrell, North Carolina BORING LOG: CLF21-13R 212013, Ph. 101 DATE STARTED: 1114121 DATE FINISHED: 11/4/21 NOTES: No SPT sampling performed, soil lithology logged from cuttings. CLF21-13R installed on 11/4/21 - see Observation Well Construction Diagramattached. SAMPLING METHOD: 3'/<" H.S.A. PERFORMED BY: J. Marlowe/S&ME WATER LEVEL: 17.12' bgs on 11/5/2021 (after well development) U Q _� a o MATERIAL DESCRIPTION w a w � v of Ui J � W SANDY SILT (ML) - soft, reddish brown tan, fine, dry, some non -plastic fines, micaceous, dry. 835. 1 834. 2 833. 3 832. 4 831. 830. 829. 7 828. 8 827. 826. 1 SILTY SAND (SM) - loose, reddish brown brown, fine, dry, some non -plastic fines, micaceous, dry. 825, 11 824. 12 823. 13 822. 14 821. 1 SANDY SILT (ML) - soft, reddish brown brown, fine, moist, some non -plastic fines, micaceous, moist to wet. 820. 1 819. 17 818. 18 817. 1 816. 2 815. 21 814. 22 813. 23 812. 24 811. 2 810. 2 809. 27 808. 28 807. 2 806. 3 805. 31 804. 32 803. 33 802. 34 801.�L 3 800. 3 799. 37 Boring terminated at 37 feet Observation Well Construction Form Ill; S&ME Project: MSS ILF Phase 2 Project Number: 212013, Phase 101 Driller/Company: Justin Marlowe (4452-A)/S&ME Well Installation Method: 3.25" HSAs Drill Rig: CME 550X Coordinates: Northing: 686085.92 Easting: 1412818.66 Borehole Diameter: 7.5" Start Date: 11/4/21 Reference Point for Measurements: Below Ground Surface Depth to Water/Date: 17.12' on 11/5/21 Completion Date: 11/4/21 Height of riser casing stick-up above ground surface (ft): 835.75 DEPTH Height of concrete pad above ground surface (in): 6 (in feet) Concrete Pad Thickness (in): 8 Ground Surface (Elevation: 835.52 ft) Bottom of Casing 0.0 Protective Surface Casing 0.2 Dia (in): 8 Type: flush mount Backfill Material Riser Casing Type: neat cement grout Type: sch. 40 PVC Dia (in): 2 Top of Seal 17.7 Annular Seal Type: coated bentonite pellets Top of Filter Pack 22.0 Top of Screen 25.0 Screen Type Dia (in): 2 (inner), 2.7 (outer) Filter Pack Type: pre -packed -sch. 40 PVC Type: #2 filter sand Slot (in.): 0.010 Bottom of Screen 35.0 Bottom of Sump 35.3 37.0 Bottom of Hole