ENR USE ONLY: ❑Paper Report ❑Electronic Data - Email CD data loaded: Yes / No Doc/Event #:
IVC DEN IEnvironmental Monitoring
Division of Waste Management - Solid Waste Reporting Form
Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are
available for inspection and examination by any person upon request (NC General Statute 132-6).
Instructions:
• Prepare one form for each individually monitored unit.
• Please type or print legibly.
• Attach a notification table with values that attain or exceed NC 2L groundwater standards or NC 2B surface water standards. The notification
must include a preliminary analysis of the cause and significance of each value. (e.g. naturally occurring, off -site source, pre-existing
condition, etc.).
• Attach a notification table of any groundwater or surface water values that equal or exceed the reporting limits.
• Attach a notification table of any methane gas values that attain or exceed explosive gas levels. This includes any structures on or nearby the
facility (NCAC 13B .1629 (4)(a)(i).
• Send the original signed and sealed form, any tables, and Electronic Data Deliverable to: Compliance Unit, NCDENR-DWM, Solid Waste
Section, 1646 Mail Service Center, Raleigh, NC 27699-1646.
Solid Waste Monitoring Data Submittal Information
Name of entity submitting data (laboratory, consultant, facility owner):
S&ME, Inc. (on behalf of Moore County)
Contact for questions about data formatting. Include data preparer's name, telephone number and E-mail address:
Name: Edmund Q.B. Henriques Phone: 336-288-7180
E-mail: ehenriques(a�smeinc.com
NC Landfill Rule: Actual sampling dates (e.g.,
Facility name: Facility Address: Facility Permit # (.0500 or .1600) October 20-24, 2006)
Moore County Landfill 456 Turning Leaf Way, Aberdeen, NC 63-01 .0500 April 12, 2021
Environmental Status: (Check all that apply)
F� Initial/Background Monitoring FX Detection Monitoring Assessment Monitoring Corrective Action
of data submitted: (Check all that apply)
Groundwater monitoring data from monitoring wells
Groundwater monitoring data from private water supply wells F-1
Leachate monitoring data ❑
Surface water monitoring data
Methane gas monitoring data
Corrective action data (specify)
Other(specify)
Notification attached?
No. No groundwater or surface water standards were exceeded.
Yes, a notification of values exceeding a groundwater or surface water standard is attached. It includes a list of groundwater and surface water
monitoring points, dates, analytical values, NC 2L groundwater standard, NC 2B surface water standard or NC Solid Waste GWPS and
preliminary analysis of the cause and significance of any concentration.
FX-] Yes, a notification of values exceeding an explosive methane gas limit is attached. It includes the methane monitoring points, dates, sample
values and explosive methane gas limits.
Certification
To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct.
Furthermore, I have attached complete notification of any sampling values meeting or exceeding groundwater standards or explosive gas
levels, and a preliminary analysis of the cause and significance of concentrations exceeding groundwater standards. I am aware that there
are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment.
Edmund Q.B. Henriques, PG Senior Geologist, S&ME Inc. 336-312-3330
Facility Representative Name (Printl Title (Area Code) Telephone Number
Affix NC Licen&'Presio eo
46.
4/28/2021
Signature N U y Date
8646 W. Market Street, Suite 105, Greensboro NC 27409
Facility Representative Address
F-0176
NC PE Firm License Number (if applicable effective May 1, 2009)
Revised 6/2009
logist Seal
x Z
o � r
r ck
Cr
OL0
D
,o t ��
NC Division of Waste Management - Solid Waste Section
Landfill Gas Monitoring Data Form
Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are
available for inspection and examination by any person upon request (NC General Statute 132-6).
Facility Name: Moore County Landfill Permit Number: 63-01
Sampling Date: 04/12/2021 NC Landfill Rule (.0500 or .1600): 0.0500
Sample collector Name & Position: Edmund Henriques / Senior Geologist (S&ME, Inc.)
Gas Meter Type & Serial Number
GEM 5000 Plus / G507243 Gas Meter Calibration Date: 11 /3/2020
Field Calibration Date & Time: 4/08/2021
Field Calibration Gas Type (15115 or 35/50): 15/15 Field Calibration Gas Canister Expiration Date: 11 /1 /25
Gas Meter Pump Rate:
696 cc/min
Ambient Air Temperature: 68 Barometric Pressure (in. or min Hg): 29.35 Weather Conditions: Sunny
Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office).
Attach a test location map or drawing. Report methane readings as both % LEL and % CH4 by volume.
Convert % CH4 (by volume) to % LEL as follows: % methane (by volume)x 20 = % LEL.
*Hydrogen Sulfide (H2S) gas monitoring may be required for Construction & Demolition Landfills (CDLFs). See individual
permit conditions andlor Facility LFG monitoring plan.
Location or
LFG Well ID
S ample
Tube
Purge
Time of
Day
Time
Pumped
(sec)
Initial
% LEL
Stabilized
% LEL
% CH4
(volume)
volume
% 02
(volume)
% CO2
(volume)
% H2S*
(volume)
NOTES
GP-9
60
1246
120
0
0
0.0
20.6
0.0
0.0
Property boundary monitoring point
GP-1 OR
60
1258
120
0
0
0.0
20.8
0.0
0.0
Property boundary monitoring point
GP-1 1
60
1 305
120
0
0
0.0
20.8
0.8
0.0
property boundary monitoring point
G P-12
60
13181
120
0
0
0.0
21.0
0.0
0.0
property boundary monitoring point
GP-13R
60
1 429
120
0
0
0.0
20.3
1.9
0.0
property boundary monitoring point
GP14R
60
1420
120
1 0
0
0.0
20.3
0.7
0.0
property boundary monitoring point
GP-1 5 R
60
1413
180
0
0
0.0
19.9
2.2
0.0
property boundary monitoring point
GP-1 6
60
1 406
120
0
0
0.0
11.5
9.8
0.0
property boundary monitoring point
GP-1 7
60
1 400
120
24
24
1.2
1.6
9.0
0.0
property boundary monitoring point
GP-1 8
60
1325
300
> 100
> 100
21.8
12.0
13.4
0.0
property boundary monitoring point
GIP-1 9
60
1350
120
0
0
0.0
17.1
3.0
0.0
property boundary monitoring point
NOTE: If needed, attach additional data forms to include additional LFG monitoring data locations for the facility.
ACTION LEVELS: Methane: >1.25% by volume (inside structures) AND >5% by volume (at facility boundary)
Hydrogen Sulfide: >1 % by volume (inside structures) AND >4% by volume (at facility boundary)
Certification
To the best of my knowledge, the information reported and statements made on this data submittal and attachments
are true and correct. I am aware that there are significant penalties for making any false statement, representation,
or certification including the possibility of a fine and imprisonment.
(2 Senior Geologist / S&ME, Inc.
SIGNATURE TITLE
Revised -February 4, 2020
NC Division of Waste Management - Solid Waste Section
Landfill Gas Monitoring Data Form
Notice: Thtsform and any information attached to it are 'Public Records"as defined in NC General Statute 132-1. As such, these documents are
available for inspection and examination by any person upon request (NC General Siatute 132-6).
Facility Name: Moore County Landfill Permit Number: 63-01
Sampling Date: 04/12/2021 NC Landfill Rule (.0500 or.1600): 0.0500
Sample collector Name & Position: Edmund Henriques / Senior Geologist (S&ME, Inc.)
Gas Meter Type & Serial Number: GEM 5000 Plus / G507243 Gas Meter Calibration Date: 11 /3/2020
Field Calibration Date & Time:
4/8/2021
Field Calibration Gas Type (15/15 or 35/50): 15/15 Field Calibration Gas Canister Expiration Date: 11/1 /25
Gas Meter Pump Rate: 696 cc/min
Ambient Air Temperature: 68 Barometric Pressure (in. or mm Hg): 29.35 Weather Conditions: Sunny
Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office).
Attach a test location map or drawing. Report methane readings as both % LEL and % CH4 by volume.
Convert %CH4 (by volume) to % LEL as follows: % methane (by volume)x 20 = %LEL.
*Hydrogen Sulfide (H2S) gas monitoring may be required for Construction di Demolition Landfills (CDLFs). See individual
permit conditions and/or Facility LFG monitoring plan.
Location or
LFG Well ID
Sample
Tube
Purge
Time of
Day
Time
Pumped
(sec)
Initial
%LEL
Stabilized
%LEL
%CH4
(volume)
%02
(volume)
%CO2
(volume)
%H2S•
(volume)
NOTES
MW-6
60
1342
120
40
40
2.0
12.4
0.7
0.0
not a compliance point
GV-33
60
1336
180
> 100
> 100
36.1
3.5
28.8
0.0
Passive vent, not a compliance point
GV-34
60
1330
180
> 100
> 100
1.6
31.0
0.0
Passive vent, not a compliance point
Bake Residence
60
1503
120
0
0
0.0
21.9
0.0
0.0
Access Get. load-awqure not monitored
Maintenance Shop
60
1440
120
0
0
0.0
21.0
0.0
0.0
On -site structure
Transfer Station
60
1311
120
0
0
0.0
20.9
0.0
0.0
On -site structure
Scale House
60
1251
120
0
0
0.0
20.6
0.1
0.0
On -site structure
NOTE: 1f needed, attach additional data forms to include additional LFG monitoring data locations for the facility.
ACTION LEVELS: Methane: >1.25%by volume (inside structures) AND >5%by volume (at facility boundary)
Hydrogen Sulfide: >1%by volume (inside structures) AND >4% by volume (at facility boundary)
Certification
To the best of my knowledge, the information reported and statements made on this data submittal and attachments
are true and correct. I am aware that there are significant penalties for making any false statement, representation,
or certification including a possibility of a fine and imprisonment.
�A,,,,,,,,�Q7•� Senior Geologist / S&ME, Inc.
SIGNATURE TITLE
Revised - February 4, 2020
Table 1
Summary of 2020 & 2022 Methane Gas Readings
Moore County Landfill (Permit 63-01)
Moore County, North Carolina
S&ME Project No. 4358-20-043A
Location
Monitoring Point
Scale- house
Type ONSS
it
Maintenance
Shop
NSS
Transfer
Station
ONSS
Blake
Crawlspace
OFFSS
GP-9
PB
r
PB
--
footnote#2
r.
PB J$B
JJB
PBJJPB
See
fo.tnot
PB
See
footnote#2
PB
PB
See
footnote#2
PB
PBJJ
PB
See
-
MW-15
PB I
seeDate
PB
02/17/20
0.0%
0.0%
0.0%
0.0%
0.0%
18.7%
not installed
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
11.9%
28.1%
not installed
04/07/20
0.0%
0.0%
0.0%
0.0%
0.0%
32.2%
not installed
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.4%
23.6%
59.9%
not installed
09/15/20
0.1%
0.0%
0.0%
0.0%
0.1%
abandoned
0.0%
0.0%
0.0%
abandoned
0.0%
abandoned
0.0%
abandoned
0.0%
0.0%
0.0%
0.0%
22.5%
0.0%
12/14/20
0.0%
0.0%
0.0%
0.1%
0.1%
abandoned
0.0%
0.0%
0.0%
abandoned
0.0%
abandoned
0.0%
abandoned
0.0%
0.0%
0.5%
9.6%
61.3%
0.0%
02/24/21
0.0%
1 0.0%
0.0%
1 NM
0.0%
abandoned
0.0%
0.0%
0.0%
abandoned
0.0%
abandoned
0.0%
abandoned
0.0%
0.0%
1.4%
28.7%
67.9%
0.0%
04/12/21
0.0%
0.0%
0.0%
0.0%
0.0%
abandoned
0.0%
0.0%
0.0%
abandoned
0.0%
abandoned
0.0%
abandoned
0.0%
0.0%
1.2%
2.0%
21.8%
0.0%
Notes.•
Monitoring Point Types: PB = Property Boundary, ONSS = On Site Structure, OFFSS = Off -site Structure
Footnote#1 = MW-6 was replace by GP-19 as the property boundary compliance point. MW-6 is approximately 150 feet inside the property boundary and not a compliance point.
Footnote#2 = GP-10 was replaced by GP-10R, GP-13 replaced by GP-13R, GP-14 replaced by GP-14R, GP-15 replaced by GP-15R
Footnote#3 = Groundwater monitoring well MW-15 converted to gas monitoring point now identified as GP-18, which is a property boundary compliance point.
all measurements recorded in percent methane by volume
Lower explosive limit of methane gas: 5%
Upper explosive limit of methane gas: 15%
Data recorded prior to 9/15/20 obtained by Golder
not installed = Well not installed at the time of monitoring
Yellow highlight cells and values in bold print indicate methane percent by volume greater than or equal to 5% at property boundary monitoring point
Orange highlight cells and values in bold print indicate methane percent by volume greater than or equal to 1.25% inside structures.
Z:\5h.red\5ME\Ops\ENV\Prolerts\2020\435&20 43AMoore CountyRoutine LFG&WQMonitoring\Task O3-Quarterly Landfill Gas\Field_Dat.\LFGReadings Tableland Char[s_INPROGREss...
r CERTIFICAtION _. WA
)PJ -
OF CA-1B#RA'TION �„ C D
_ No. 66-9 f6
Date Of Calibration:. 03-Mov-2020 Certificate Number: G507249140355
• _.-
Issued by:•QED Envirorrrperi�al Systems in
� -
Customer: Geotech Environmental Equipment Inc
2650 E 40th Ave Denver, CO 80205 USA
Description: Landtec Gas Analyzer
Model: GEM5000
Serial Number: G507243
Accredited Results:
nnott,-A.,e /ruAV
-Certified Gas(%)
Instrument Reading A
Uncertainty
5.0
4:8.
0.42..
15.0 _.:
14,8r
�0;66
50.0 -
49.7
f .0
Carbon Dioxide 1CO2
Certified Gas • %
Instrument Reading %
Uncertainty
4.9 '
4.6
0.43
15.0
14.5
0.71
50.0
5072
1.19
Oxygen 02
Certified Gas %
Instrument Reading
Uncertainty
20.9
21.0
0.25
Gas cylinders are traceable and details can be provided if
requested.
CH4, CO2 readings recorded at! 31.1 °C/88.0 °F Barometric Pressure: 0985"Hg/29.08 "Hg
02 readings recorded at:- 22.4 °C/72.3 °F
Method of Test : The analyzer is calibrated in a temperature controlled chamber using a series of reference
gases, in compliance with procedure ISP17.
The reported expanded uncertainty is based on a standard uncertainty multiplied by a coverage factor of k=2,
providing a level of confidence"of approximately 95%. The uncertainty evaluation has been carried out in accordance
with NIST -requirements: -
The calibration results published in this certificate were obtained using equipment capable of producing results that are traceable through NIST to the International System of
Units (SI): Certification only applies to results shown. This certificate may not be reproduced other than in full, except with the prior written approval of the issuing laboratory.
Calibration Instance: 107 IGC Instance: N/A Page 1 6f2I LPOISLNANIST-l.l
www:_gedenv.co•m (800) 624-2026 info@qedenv.com
QED En'viro_gmental Systems Inc. 2355 Bishop Circle West, Dexter, MI 48130
P PP
PP
CERTIF.ICATI.ON
Of CALIBRAIFO-WNo.
MIA
66916
-Date.Of Calibration: 03-Nov-2020
Issued by: QED Environmental Systems Inc.
Non Accredited results:
„I:� �
VQ
Certificate Number: G507243_9/40355
Pressure Transducers inches of water column
Transducer Certified (Low) Reading (Low) Certified (High) Reading (High) Accuracy
static
0"
0"
40"
40.12"
2.0"
Differential
0"
0"
4"
4.02"
0.7"
As received gas check readings are only recorded if the instrument is received in a workingtondition.
Where the instrument is received damaged no reading an b aken.
Date of Issue : 04 Nov 2020 Approved By Signatory
Kyle Racine
Laboratory Inspection
The calibration results published in this certificate were obtained using equipment capable of producing results that are traceable through NIST to the International System of
Units (SI). Certification only applies to results shown. This certificate may not be reproduced other than in full, except with the prior written approval of the issuing laboratory.
Calibration Instance: 107 IGC Instance: N/A Page 2 of 21 LP015LNANIST-I.•I
www.qedenv.com (800) 624-2026 info@gedenv.com
QED Environmental Systems Inc. 2355 Bishop Circle West, Dexter, MI 48130
ENVIRO-EQUIPMENT', INC.
LANDTEC GEM 5000 Plus CALIBRATION DATA SHEET
Serial Number Date Date Inspector i(-!50
Time/Date Battery Level a Memory Cleared Pump Faults C*0�-j—
Gas Alarms: CH4 = 100.0% ICDLxA COZ = 100.0% Q 0, = 22.0% Q
Zero Transducers Pump Flow Rate /M(v) Vacuum Tested To 80" H2O
Calibration Gas
Pure N2
High CH4
High CO,
Low CH4
Low CO,
Low OZ
High 02
CO
HZS
Calibration Check (Performed at Room Temperature)
Calibration Gas
Concentration
>Q�.�lgII7o
�10
35�10
rJ�o
20.9% -
St��h,,
IQ� �rh
Lot Number
Expiration
r
l k Z02CE)
LL,(2 25
N/A
2 Z3
�2�23
Reading Accuracy*
*Accuracy depends upon calibration range; 15%-FS range for CH4 &-0O2, 0-5% volume for 02, 0%-FS for H S, and 10% of reading for CU.
INSPECTOR'S MAINTENANCE NOTES
EEl GEM 2000 Plus Cal Form 01/12