Loading...
HomeMy WebLinkAboutCCB0051_TerrySmith_DWRStreamSampleReport_20201008PO Number # Loc. Descr.:TM-UT UPSTREAM Loc. Type:River/Stream Collector:BC/AP Collect Date:09/18/2020 Collect Time:12:40 Date Received:09/22/2020 Time Received:08:20 Location ID:MRO_NLC County:IREDELL Region:MRO Labworks LoginID MSWIFTSample Matrix:SURFACEWATER Report Print Date: North Carolina Division of Water Resources Water Sciences Section Laboratory Results VisitID Sample Depth MROReport To CTBRiver Basin 10/08/2020 YesEmergency COC Yes/No Sample ID:AC77126 10/8/20Final Report Date: Final Report If this report is labeled preliminary report, the results have not been validated. Do not use for Regulatory purposes. NC CourierDelivery Method EMERGENCYPriority AC77126 Analysis Date Method Reference Result/ QualifierPQLAnalyte NameCAS #Units Validated by LAB Sample temperature at receipt by lab AWILLIAMS°CSample temperature at receipt by lab 9/22/200.2 MET Ag by ICPMS EPA 200.8 Rev5.4 ESTAFFORD1ug/LUAg by ICPMS7440-22-4 9/23/201.0 1.0 Al by ICP EPA 200.7 Rev4.4 ESTAFFORD1ug/LAl by ICP7429-90-5 9/23/2050420 Antimony by ICPMS EPA 200.8 Rev5.4 ESTAFFORD1ug/LUAntimony by ICPMS7440-36-0 9/23/201010 As by ICPMS EPA 200.8 Rev5.4 ESTAFFORD1ug/LUAs by ICPMS7440-38-2 9/23/202.0 2.0 B by ICP EPA 200.7 Rev4.4 ESTAFFORD1ug/LUB by ICP7429-90-5 9/23/205050 Ba by ICP EPA 200.7 Rev4.4 ESTAFFORD1ug/LBa by ICP7440-38-3 9/23/201064 Be by ICP EPA 200.7 Rev4.4 ESTAFFORD1ug/LUBe by ICP7440-41-7 9/23/205.0 5.0 Ca by ICP EPA 200.7 Rev4.4 ESTAFFORD1mg/LCa by ICP7440-70-2 9/23/200.10 12 Cd by ICPMS EPA 200.8 Rev5.4 ESTAFFORD1ug/LUCd by ICPMS7440-43-9 9/23/200.50 0.50 Cobalt by ICP EPA 200.7 Rev4.4 ESTAFFORD1ug/LUCobalt by ICP7440-48-4 9/23/205050 Cr by ICPMS EPA 200.8 Rev5.4 ESTAFFORD1ug/LUCr by ICPMS7440-47-3 9/23/205.0 5.0 Cu by ICPMS EPA 200.8 Rev5.4 ESTAFFORD1ug/LUCu by ICPMS7440-50-8 9/23/202.0 2.0 Fe by ICP WSS Chemistry Laboratory>> 1623 Mail Service Center, Raleigh, NC 27699-1623 (919) 733-3908 Page 1 of 2 "Not Detected" or "U" does not indicate the sample is analyte free but that the analyte is not detected at or above the PQL. AC77126Sample ID: NC DWR Laboratory Section Results/Sample Comments/Qualifier Definitions CAS #Analyte Name PQL Result/ Qualifier Units Method Reference Analysis Date Validated by EPA 200.7 Rev4.4 ESTAFFORD1ug/LFe by ICP7439-89-6 9/23/20501200 Hg 245.1 EPA 245.1 Rev3 ESTAFFORD1ug/LUHg 245.17439-97-6 9/24/200.2 0.20 K by ICP EPA 200.7 Rev4.4 ESTAFFORD1mg/LK by ICP7440-09-7 9/23/200.10 3.7 Li ICP EPA 200.7 Rev4.4 ESTAFFORD1ug/LULi ICP7439-93-2 9/23/202525 Mg by ICP EPA 200.7 Rev4.4 ESTAFFORD1mg/LMg by ICP7439-95-4 9/23/200.10 2.4 Mn by ICP EPA 200.7 Rev4.4 ESTAFFORD1ug/LMn by ICP7439-96-5 9/23/2010170 Mo by ICPMS EPA 200.8 Rev5.4 ESTAFFORD1ug/LUMo by ICPMS7439-98-7 9/23/201010 Na by ICP EPA 200.7 Rev4.4 ESTAFFORD1mg/LNa by ICP7440-23-5 9/23/200.10 5.9 Ni by ICPMS EPA 200.8 Rev5.4 ESTAFFORD1ug/LUNi by ICPMS7440-02-0 9/23/202.0 2.0 Pb by ICPMS EPA 200.8 Rev5.4 ESTAFFORD1ug/LUPb by ICPMS7439-92-1 9/23/202.0 2.0 Se by ICPMS EPA 200.8 Rev5.4 ESTAFFORD1ug/LUSe by ICPMS7782-49-2 9/23/201.0 1.0 Sn by ICPMS EPA 200.8 Rev5.4 ESTAFFORD1ug/LUSn by ICPMS7440-31-5 9/23/201010 Sr by ICPMS EPA 200.8 Rev5.4 ESTAFFORD1ug/LSr by ICPMS7440-24-6 9/23/2010180 Thallium (Tl) ICPMS EPA 200.8 Rev5.4 ESTAFFORD1ug/LUThallium (Tl) ICPMS7440-28-0 9/23/202.0 2.0 Ti (Titanium) by ICP EPA 200.7 Rev4.4 ESTAFFORD1ug/LTi (Titanium) by ICP7440-32-6 9/23/201015 V by ICP EPA 200.7 Rev4.4 ESTAFFORD1ug/LUV by ICP7440-62-2 9/23/201010 Zn by ICPMS EPA 200.8 Rev5.4 ESTAFFORD1ug/LUZn by ICPMS7440-66-6 9/23/201010 WSS Chemistry Laboratory>> 1623 Mail Service Center, Raleigh, NC 27699-1623 (919) 733-3908 Page 2 of 2 "Not Detected" or "U" does not indicate the sample is analyte free but that the analyte is not detected at or above the PQL. PO Number # Loc. Descr.:TM-OUTFALL Loc. Type:River/Stream Collector:BC/AP Collect Date:09/18/2020 Collect Time:12:55 Date Received:09/22/2020 Time Received:08:20 Location ID:MRO_NLC County:IREDELL Region:Mooresville Labworks LoginID MSWIFTSample Matrix:SURFACEWATER Report Print Date: North Carolina Division of Water Resources Water Sciences Section Laboratory Results VisitID Sample Depth MROReport To CTBRiver Basin 10/08/2020 YesEmergency COC Yes/No Sample ID:AC77127 10/8/20Final Report Date: Final Report If this report is labeled preliminary report, the results have not been validated. Do not use for Regulatory purposes. NC CourierDelivery Method EMERGENCYPriority AC77127 Analysis Date Method Reference Result/ QualifierPQLAnalyte NameCAS #Units Validated by LAB Sample temperature at receipt by lab AWILLIAMS°CSample temperature at receipt by lab 9/22/200.2 MET Ag by ICPMS EPA 200.8 Rev5.4 ESTAFFORD1ug/LUAg by ICPMS7440-22-4 9/23/201.0 1.0 Al by ICP EPA 200.7 Rev4.4 ESTAFFORD1ug/LAl by ICP7429-90-5 9/23/2050670 Antimony by ICPMS EPA 200.8 Rev5.4 ESTAFFORD1ug/LUAntimony by ICPMS7440-36-0 9/23/201010 As by ICPMS EPA 200.8 Rev5.4 ESTAFFORD1ug/LUAs by ICPMS7440-38-2 9/23/202.0 2.0 B by ICP EPA 200.7 Rev4.4 ESTAFFORD1ug/LB by ICP7429-90-5 9/23/205067 Ba by ICP EPA 200.7 Rev4.4 ESTAFFORD1ug/LBa by ICP7440-38-3 9/23/201065 Be by ICP EPA 200.7 Rev4.4 ESTAFFORD1ug/LUBe by ICP7440-41-7 9/23/205.0 5.0 Ca by ICP EPA 200.7 Rev4.4 ESTAFFORD1mg/LCa by ICP7440-70-2 9/23/200.10 15 Cd by ICPMS EPA 200.8 Rev5.4 ESTAFFORD1ug/LUCd by ICPMS7440-43-9 9/23/200.50 0.50 Cobalt by ICP EPA 200.7 Rev4.4 ESTAFFORD1ug/LUCobalt by ICP7440-48-4 9/23/205050 Cr by ICPMS EPA 200.8 Rev5.4 ESTAFFORD1ug/LUCr by ICPMS7440-47-3 9/23/205.0 5.0 Cu by ICPMS EPA 200.8 Rev5.4 ESTAFFORD1ug/LUCu by ICPMS7440-50-8 9/23/202.0 2.0 Fe by ICP WSS Chemistry Laboratory>> 1623 Mail Service Center, Raleigh, NC 27699-1623 (919) 733-3908 Page 1 of 2 "Not Detected" or "U" does not indicate the sample is analyte free but that the analyte is not detected at or above the PQL. AC77127Sample ID: NC DWR Laboratory Section Results/Sample Comments/Qualifier Definitions CAS #Analyte Name PQL Result/ Qualifier Units Method Reference Analysis Date Validated by EPA 200.7 Rev4.4 ESTAFFORD1ug/LFe by ICP7439-89-6 9/23/20501700 Hg 245.1 EPA 245.1 Rev3 ESTAFFORD1ug/LUHg 245.17439-97-6 9/24/200.2 0.20 K by ICP EPA 200.7 Rev4.4 ESTAFFORD1mg/LK by ICP7440-09-7 9/23/200.10 4.0 Li ICP EPA 200.7 Rev4.4 ESTAFFORD1ug/LULi ICP7439-93-2 9/23/202525 Mg by ICP EPA 200.7 Rev4.4 ESTAFFORD1mg/LMg by ICP7439-95-4 9/23/200.10 2.6 Mn by ICP EPA 200.7 Rev4.4 ESTAFFORD1ug/LMn by ICP7439-96-5 9/23/2010200 Mo by ICPMS EPA 200.8 Rev5.4 ESTAFFORD1ug/LUMo by ICPMS7439-98-7 9/23/201010 Na by ICP EPA 200.7 Rev4.4 ESTAFFORD1mg/LNa by ICP7440-23-5 9/23/200.10 6.2 Ni by ICPMS EPA 200.8 Rev5.4 ESTAFFORD1ug/LUNi by ICPMS7440-02-0 9/23/202.0 2.0 Pb by ICPMS EPA 200.8 Rev5.4 ESTAFFORD1ug/LUPb by ICPMS7439-92-1 9/23/202.0 2.0 Se by ICPMS EPA 200.8 Rev5.4 ESTAFFORD1ug/LUSe by ICPMS7782-49-2 9/23/201.0 1.0 Sn by ICPMS EPA 200.8 Rev5.4 ESTAFFORD1ug/LUSn by ICPMS7440-31-5 9/23/201010 Sr by ICPMS EPA 200.8 Rev5.4 ESTAFFORD1ug/LSr by ICPMS7440-24-6 9/23/2010200 Thallium (Tl) ICPMS EPA 200.8 Rev5.4 ESTAFFORD1ug/LUThallium (Tl) ICPMS7440-28-0 9/23/202.0 2.0 Ti (Titanium) by ICP EPA 200.7 Rev4.4 ESTAFFORD1ug/LTi (Titanium) by ICP7440-32-6 9/23/201025 V by ICP EPA 200.7 Rev4.4 ESTAFFORD1ug/LUV by ICP7440-62-2 9/23/201010 Zn by ICPMS EPA 200.8 Rev5.4 ESTAFFORD1ug/LZn by ICPMS7440-66-6 9/23/201024 WSS Chemistry Laboratory>> 1623 Mail Service Center, Raleigh, NC 27699-1623 (919) 733-3908 Page 2 of 2 "Not Detected" or "U" does not indicate the sample is analyte free but that the analyte is not detected at or above the PQL. PO Number # Loc. Descr.:TM-DS@BRAWLEY Loc. Type:River/Stream Collector:BC/AP Collect Date:09/18/2020 Collect Time:13:30 Date Received:09/22/2020 Time Received:08:20 Location ID:MRO_NLC County:IREDELL Region:Mooresville Labworks LoginID MSWIFTSample Matrix:SURFACEWATER Report Print Date: North Carolina Division of Water Resources Water Sciences Section Laboratory Results VisitID Sample Depth MROReport To CTBRiver Basin 10/08/2020 YesEmergency COC Yes/No Sample ID:AC77128 10/8/20Final Report Date: Final Report If this report is labeled preliminary report, the results have not been validated. Do not use for Regulatory purposes. NC CourierDelivery Method EMERGENCYPriority AC77128 Analysis Date Method Reference Result/ QualifierPQLAnalyte NameCAS #Units Validated by LAB Sample temperature at receipt by lab AWILLIAMS°CSample temperature at receipt by lab 9/22/200.2 MET Ag by ICPMS EPA 200.8 Rev5.4 ESTAFFORD1ug/LUAg by ICPMS7440-22-4 9/23/201.0 1.0 Al by ICP EPA 200.7 Rev4.4 ESTAFFORD1ug/LAl by ICP7429-90-5 9/23/2050880 Antimony by ICPMS EPA 200.8 Rev5.4 ESTAFFORD1ug/LUAntimony by ICPMS7440-36-0 9/23/201010 As by ICPMS EPA 200.8 Rev5.4 ESTAFFORD1ug/LAs by ICPMS7440-38-2 9/24/202.0 2.0 B by ICP EPA 200.7 Rev4.4 ESTAFFORD1ug/LB by ICP7429-90-5 9/23/205051 Ba by ICP EPA 200.7 Rev4.4 ESTAFFORD1ug/LBa by ICP7440-38-3 9/23/201073 Be by ICP EPA 200.7 Rev4.4 ESTAFFORD1ug/LUBe by ICP7440-41-7 9/23/205.0 5.0 Ca by ICP EPA 200.7 Rev4.4 ESTAFFORD1mg/LCa by ICP7440-70-2 9/23/200.10 15 Cd by ICPMS EPA 200.8 Rev5.4 ESTAFFORD1ug/LUCd by ICPMS7440-43-9 9/23/200.50 0.50 Cobalt by ICP EPA 200.7 Rev4.4 ESTAFFORD1ug/LUCobalt by ICP7440-48-4 9/23/205050 Cr by ICPMS EPA 200.8 Rev5.4 ESTAFFORD1ug/LUCr by ICPMS7440-47-3 9/23/205.0 5.0 Cu by ICPMS EPA 200.8 Rev5.4 ESTAFFORD1ug/LCu by ICPMS7440-50-8 9/23/202.0 2.0 Fe by ICP WSS Chemistry Laboratory>> 1623 Mail Service Center, Raleigh, NC 27699-1623 (919) 733-3908 Page 1 of 4 "Not Detected" or "U" does not indicate the sample is analyte free but that the analyte is not detected at or above the PQL. AC77128Sample ID: NC DWR Laboratory Section Results/Sample Comments/Qualifier Definitions CAS #Analyte Name PQL Result/ Qualifier Units Method Reference Analysis Date Validated by EPA 200.7 Rev4.4 ESTAFFORD1ug/LFe by ICP7439-89-6 9/23/20501100 Hg 245.1 EPA 245.1 Rev3 ESTAFFORD1ug/LUHg 245.17439-97-6 9/24/200.2 0.20 K by ICP EPA 200.7 Rev4.4 ESTAFFORD1mg/LK by ICP7440-09-7 9/23/200.10 3.8 Li ICP EPA 200.7 Rev4.4 ESTAFFORD1ug/LULi ICP7439-93-2 9/23/202525 Mg by ICP EPA 200.7 Rev4.4 ESTAFFORD1mg/LMg by ICP7439-95-4 9/23/200.10 2.4 Mn by ICP EPA 200.7 Rev4.4 ESTAFFORD1ug/LMn by ICP7439-96-5 9/23/201054 Mo by ICPMS EPA 200.8 Rev5.4 ESTAFFORD1ug/LUMo by ICPMS7439-98-7 9/23/201010 Na by ICP EPA 200.7 Rev4.4 ESTAFFORD1mg/LNa by ICP7440-23-5 9/23/200.10 6.0 Ni by ICPMS EPA 200.8 Rev5.4 ESTAFFORD1ug/LUNi by ICPMS7440-02-0 9/23/202.0 2.0 Pb by ICPMS EPA 200.8 Rev5.4 ESTAFFORD1ug/LUPb by ICPMS7439-92-1 9/23/202.0 2.0 Se by furnace EPA 200.9 Rev2.2 ESTAFFORD1ug/LU, J2Se by furnace7782-49-2 9/24/201.0 1.0 Sn by ICPMS EPA 200.8 Rev5.4 ESTAFFORD1ug/LUSn by ICPMS7440-31-5 9/23/201010 Sr by ICPMS EPA 200.8 Rev5.4 ESTAFFORD1ug/LSr by ICPMS7440-24-6 9/23/2010210 Thallium (Tl) ICPMS EPA 200.8 Rev5.4 ESTAFFORD1ug/LUThallium (Tl) ICPMS7440-28-0 9/23/202.0 2.0 Ti (Titanium) by ICP EPA 200.7 Rev4.4 ESTAFFORD1ug/LTi (Titanium) by ICP7440-32-6 9/23/201031 V by ICP EPA 200.7 Rev4.4 ESTAFFORD1ug/LUV by ICP7440-62-2 9/23/201010 Zn by ICPMS EPA 200.8 Rev5.4 ESTAFFORD1ug/LUZn by ICPMS7440-66-6 9/23/201010 WSS Chemistry Laboratory>> 1623 Mail Service Center, Raleigh, NC 27699-1623 (919) 733-3908 Page 2 of 4 "Not Detected" or "U" does not indicate the sample is analyte free but that the analyte is not detected at or above the PQL. AC77128Sample ID: NC DWR Laboratory Section Results/Sample Comments/Qualifier Definitions CAS #Analyte Name PQL Result/ Qualifier Units Method Reference Analysis Date Validated by MET: Se - J2 - Estimated - LFM < 85% (84.6%). Sample Comments NCDEQ-WSS-Chemistry Lab Data Qualifiers A1 The reported value is an average, where at least one result is qualified with a “U”. The PQL is used for the qualified result(S) to calculate the average. B1 Coliform-Countable membranes with less than 20 colonies. Reported value is estimated or is a total of the counts on all filters reported per 100 ml. B2 Coliform-Counts from all filters were zero. The value reported is based on the number of colonies per 100 ml that would have been reported if there had been one colony on the filter representing the largest filtration volume. B3 Coliform-Countable membranes with more than 60 or 80 colonies. The value reported is calculated using the count from the smallest volume filtered and reported as a greater than ">" value. B4 Coliform-Filters have counts of both >60 or 80 and <20. Reported value is estimated or is a total of the counts on all filters reported per 100 ml. B5 Coliform-Too many colonies were present; too numerous to count (TNTC). TNTC is generally defined as >150 colonies. B6 Coliform-Estimated Value. Blank contamination evident. B7 Coliform-Many non-coliform or non-enterococcus colonies or interfering non-coliform or non-enterococcus growth present. In this competitive situation, the reported value may under-represent actual density. BB1 MPN-No wells or tubes gave a positive reaction. Value based upon the appropriate MPN Index and reported as a less than “<” value. BB2 MPN-All wells or tubes gave positive reactions. Value based upon the MPN Index and reported as a greater than “>” value. C Total residual chlorine was present in sample upon receipt in the laboratory; value is estimated. G1 BOD-The dissolved oxygen (DO) depletion of the dilution water blank exceeded 0.2 mg/L. G2 BOD-The bacterial seed controls did not meet the requirement of a DO depletion of at least 2.0 mg/L and/or a DO residual of at least 1.0 mg/L. G3 BOD-No sample dilution met the requirement of a DO depletion of at least 2.0 mg/L and/or a DO residual of at least 1.0 mg/L. G4 BOD-Evidence of toxicity. This is generally characterized by a significant increase in the BOD value as the sample concentration decreases. The reported value is calculated from the highest dilution representing the maximum loading potential and G5 BOD-The glucose/ glutamic acid standard exceeded the range of 198 ± 30.5 mg/L. G7 BOD-Less than 1 mg/L DO remained for all dilutions set. The reported value is an estimated greater than value and is calculated for the dilution using the least amount of sample. G8 BOD-Oxygen usage is less than 2 mg/L for all dilutions set. The reported value is an estimated less than value and is calculated for the dilution using the most amount of sample. G9 BOD-The DO depletion of the dilution water blank produced a negative value. J1 Surrogate recovery limits have been exceeded. J10 Unidentified peak; estimated value. J11 The reported value is determined by a one-point estimation rather than against a regression equation. The estimated concentration is less than the laboratory practical quantitation limit and greater than the instrument noise level. This code is used when WSS Chemistry Laboratory>> 1623 Mail Service Center, Raleigh, NC 27699-1623 (919) 733-3908 Page 3 of 4 "Not Detected" or "U" does not indicate the sample is analyte free but that the analyte is not detected at or above the PQL. AC77128Sample ID: NC DWR Laboratory Section Results/Sample Comments/Qualifier Definitions CAS #Analyte Name PQL Result/ Qualifier Units Method Reference Analysis Date Validated by J12 The calibration verification did not meet the calibration acceptance criterion for field parameters. J2 The reported value failed to meet the established quality control criteria for either precision or accuracy. J3 The sample matrix interfered with the ability to make any accurate determination. J4 The data is questionable because of improper laboratory or field protocols (e.g., composite sample was collected instead of grab, plastic instead of glass container, etc.). J5 Temperature limits exceeded (samples frozen or >6°C) during transport or not verifiable (e.g., no temperature blank provided): non-reportable for NPDES compliance monitoring. J6 The laboratory analysis was from an unpreserved or improperly chemically preserved sample. The data may not be accurate. J7 This qualifier is used to identify analyte concentration exceeding the upper calibration range of the analytical instrument/method. The reported value should be considered estimated. J8 Temperature limits exceeded (samples frozen or >6ºC) during storage, the data may not be accurate. J9 The reported value is determined by a one-point estimation rather than against a regression equation. The estimated concentration is less than the laboratory practical quantitation limit and greater than the laboratory method detection limit. M Sample and duplicate results are "out of control". The sample is non-homogenous (e.g., VOA soil). The reported value is the lower value of duplicate analyses of a sample. N1 Presumptive evidence and estimated value. The component has been tentatively identified base on mass spectral library. N2 There is an indication that the analyte is present, but quality control requirements for confirmation were not met (i.e., presence of analyte was not confirmed by alternate procedures). N3 This code shall be used if the level is too low to permit accurate quantification, but the estimated concentration is less than the laboratory practical quantitation limit and greater than the laboratory method detection limit. This code is not routinely N4 This code shall be used if the level is too low to permit accurate quantification, but the estimated concentration is less than the laboratory practical quantitation limit and greater than the instrument noise level. This code is used when an MDL has not N5 The component has been tentatively identified based on a retention time standard. P Elevated PQL* due to matrix interference and/or sample dilution. Q1 Holding time exceeded prior to receipt by lab. Q2 Holding time exceeded following receipt by lab. S Not enough sample provided to prepare and/or analyze a method-required matrix spike (MS) and/or matrix spike duplicate (MSD). U Indicates that the analyte was analyzed for but not detected above the reported practical quantitation limit*. The number value reported with the "U" qualifier is equal to the laboratory's practical quantitation limit*. U, J6 The laboratory analysis was from an unpreserved or improperly chemically preserved sample. The data may not be accurate. UU Indicates that the analyte was not detected by a screen analysis. The number value was determined by a one-point estimation at the PQL. V Indicates the analyte was detected in both the sample and the associated method blank. Note: The value in the blank shall not be subtracted from the associated samples. X1 Sample not screened for this compound. X2 Sampled, but analysis lost or not performed-field error. X3 Sampled, but analysis lost or not performed-lab error. Y Elevated PQL* due to insufficient sample size. Z1 Inability to analyze the sample. Z2 Questions concerning data reliability. WSS Chemistry Laboratory>> 1623 Mail Service Center, Raleigh, NC 27699-1623 (919) 733-3908 Page 4 of 4 "Not Detected" or "U" does not indicate the sample is analyte free but that the analyte is not detected at or above the PQL. PO Number # Loc. Descr.:TM-CONFLUENCE @LKN Loc. Type:River/Stream Collector:BC/AP Collect Date:09/18/2020 Collect Time:14:00 Date Received:09/22/2020 Time Received:08:20 Location ID:MRO_NLC County:IREDELL Region:Mooresville Labworks LoginID MSWIFTSample Matrix:SURFACEWATER Report Print Date: North Carolina Division of Water Resources Water Sciences Section Laboratory Results VisitID Sample Depth MROReport To CTBRiver Basin 10/08/2020 YesEmergency COC Yes/No Sample ID:AC77129 10/8/20Final Report Date: Final Report If this report is labeled preliminary report, the results have not been validated. Do not use for Regulatory purposes. NC CourierDelivery Method EMERGENCYPriority AC77129 Analysis Date Method Reference Result/ QualifierPQLAnalyte NameCAS #Units Validated by LAB Sample temperature at receipt by lab AWILLIAMS°CSample temperature at receipt by lab 9/22/200.2 MET Ag by ICPMS EPA 200.8 Rev5.4 ESTAFFORD1ug/LUAg by ICPMS7440-22-4 9/23/201.0 1.0 Al by ICP EPA 200.7 Rev4.4 ESTAFFORD1ug/LAl by ICP7429-90-5 9/23/20501400 Antimony by ICPMS EPA 200.8 Rev5.4 ESTAFFORD1ug/LUAntimony by ICPMS7440-36-0 9/23/201010 As by ICPMS EPA 200.8 Rev5.4 ESTAFFORD1ug/LAs by ICPMS7440-38-2 9/24/202.0 2.4 B by ICP EPA 200.7 Rev4.4 ESTAFFORD1ug/LUB by ICP7429-90-5 9/23/205050 Ba by ICP EPA 200.7 Rev4.4 ESTAFFORD1ug/LBa by ICP7440-38-3 9/23/201076 Be by ICP EPA 200.7 Rev4.4 ESTAFFORD1ug/LUBe by ICP7440-41-7 9/23/205.0 5.0 Ca by ICP EPA 200.7 Rev4.4 ESTAFFORD1mg/LCa by ICP7440-70-2 9/23/200.10 14 Cd by ICPMS EPA 200.8 Rev5.4 ESTAFFORD1ug/LUCd by ICPMS7440-43-9 9/23/200.50 0.50 Cobalt by ICP EPA 200.7 Rev4.4 ESTAFFORD1ug/LUCobalt by ICP7440-48-4 9/23/205050 Cr by ICPMS EPA 200.8 Rev5.4 ESTAFFORD1ug/LUCr by ICPMS7440-47-3 9/23/205.0 5.0 Cu by ICPMS EPA 200.8 Rev5.4 ESTAFFORD1ug/LCu by ICPMS7440-50-8 9/23/202.0 2.6 Fe by ICP WSS Chemistry Laboratory>> 1623 Mail Service Center, Raleigh, NC 27699-1623 (919) 733-3908 Page 1 of 4 "Not Detected" or "U" does not indicate the sample is analyte free but that the analyte is not detected at or above the PQL. AC77129Sample ID: NC DWR Laboratory Section Results/Sample Comments/Qualifier Definitions CAS #Analyte Name PQL Result/ Qualifier Units Method Reference Analysis Date Validated by EPA 200.7 Rev4.4 ESTAFFORD1ug/LFe by ICP7439-89-6 9/23/20501600 Hg 245.1 EPA 245.1 Rev3 ESTAFFORD1ug/LUHg 245.17439-97-6 9/24/200.2 0.20 K by ICP EPA 200.7 Rev4.4 ESTAFFORD1mg/LK by ICP7440-09-7 9/23/200.10 3.8 Li ICP EPA 200.7 Rev4.4 ESTAFFORD1ug/LULi ICP7439-93-2 9/23/202525 Mg by ICP EPA 200.7 Rev4.4 ESTAFFORD1mg/LMg by ICP7439-95-4 9/23/200.10 2.4 Mn by ICP EPA 200.7 Rev4.4 ESTAFFORD1ug/LMn by ICP7439-96-5 9/23/201067 Mo by ICPMS EPA 200.8 Rev5.4 ESTAFFORD1ug/LUMo by ICPMS7439-98-7 9/23/201010 Na by ICP EPA 200.7 Rev4.4 ESTAFFORD1mg/LNa by ICP7440-23-5 9/23/200.10 5.5 Ni by ICPMS EPA 200.8 Rev5.4 ESTAFFORD1ug/LUNi by ICPMS7440-02-0 9/23/202.0 2.0 Pb by ICPMS EPA 200.8 Rev5.4 ESTAFFORD1ug/LUPb by ICPMS7439-92-1 9/23/202.0 2.0 Se by furnace EPA 200.9 Rev2.2 ESTAFFORD1ug/LU, J2Se by furnace7782-49-2 9/24/201.0 1.0 Sn by ICPMS EPA 200.8 Rev5.4 ESTAFFORD1ug/LUSn by ICPMS7440-31-5 9/23/201010 Sr by ICPMS EPA 200.8 Rev5.4 ESTAFFORD1ug/LSr by ICPMS7440-24-6 9/23/2010200 Thallium (Tl) ICPMS EPA 200.8 Rev5.4 ESTAFFORD1ug/LUThallium (Tl) ICPMS7440-28-0 9/23/202.0 2.0 Ti (Titanium) by ICP EPA 200.7 Rev4.4 ESTAFFORD1ug/LTi (Titanium) by ICP7440-32-6 9/23/201058 V by ICP EPA 200.7 Rev4.4 ESTAFFORD1ug/LUV by ICP7440-62-2 9/23/201010 Zn by ICPMS EPA 200.8 Rev5.4 ESTAFFORD1ug/LUZn by ICPMS7440-66-6 9/23/201010 WSS Chemistry Laboratory>> 1623 Mail Service Center, Raleigh, NC 27699-1623 (919) 733-3908 Page 2 of 4 "Not Detected" or "U" does not indicate the sample is analyte free but that the analyte is not detected at or above the PQL. AC77129Sample ID: NC DWR Laboratory Section Results/Sample Comments/Qualifier Definitions CAS #Analyte Name PQL Result/ Qualifier Units Method Reference Analysis Date Validated by MET: Se - J2 - Estimated - LFM < 85% (84.6%). Sample Comments NCDEQ-WSS-Chemistry Lab Data Qualifiers A1 The reported value is an average, where at least one result is qualified with a “U”. The PQL is used for the qualified result(S) to calculate the average. B1 Coliform-Countable membranes with less than 20 colonies. Reported value is estimated or is a total of the counts on all filters reported per 100 ml. B2 Coliform-Counts from all filters were zero. The value reported is based on the number of colonies per 100 ml that would have been reported if there had been one colony on the filter representing the largest filtration volume. B3 Coliform-Countable membranes with more than 60 or 80 colonies. The value reported is calculated using the count from the smallest volume filtered and reported as a greater than ">" value. B4 Coliform-Filters have counts of both >60 or 80 and <20. Reported value is estimated or is a total of the counts on all filters reported per 100 ml. B5 Coliform-Too many colonies were present; too numerous to count (TNTC). TNTC is generally defined as >150 colonies. B6 Coliform-Estimated Value. Blank contamination evident. B7 Coliform-Many non-coliform or non-enterococcus colonies or interfering non-coliform or non-enterococcus growth present. In this competitive situation, the reported value may under-represent actual density. BB1 MPN-No wells or tubes gave a positive reaction. Value based upon the appropriate MPN Index and reported as a less than “<” value. BB2 MPN-All wells or tubes gave positive reactions. Value based upon the MPN Index and reported as a greater than “>” value. C Total residual chlorine was present in sample upon receipt in the laboratory; value is estimated. G1 BOD-The dissolved oxygen (DO) depletion of the dilution water blank exceeded 0.2 mg/L. G2 BOD-The bacterial seed controls did not meet the requirement of a DO depletion of at least 2.0 mg/L and/or a DO residual of at least 1.0 mg/L. G3 BOD-No sample dilution met the requirement of a DO depletion of at least 2.0 mg/L and/or a DO residual of at least 1.0 mg/L. G4 BOD-Evidence of toxicity. This is generally characterized by a significant increase in the BOD value as the sample concentration decreases. The reported value is calculated from the highest dilution representing the maximum loading potential and G5 BOD-The glucose/ glutamic acid standard exceeded the range of 198 ± 30.5 mg/L. G7 BOD-Less than 1 mg/L DO remained for all dilutions set. The reported value is an estimated greater than value and is calculated for the dilution using the least amount of sample. G8 BOD-Oxygen usage is less than 2 mg/L for all dilutions set. The reported value is an estimated less than value and is calculated for the dilution using the most amount of sample. G9 BOD-The DO depletion of the dilution water blank produced a negative value. J1 Surrogate recovery limits have been exceeded. J10 Unidentified peak; estimated value. J11 The reported value is determined by a one-point estimation rather than against a regression equation. The estimated concentration is less than the laboratory practical quantitation limit and greater than the instrument noise level. This code is used when WSS Chemistry Laboratory>> 1623 Mail Service Center, Raleigh, NC 27699-1623 (919) 733-3908 Page 3 of 4 "Not Detected" or "U" does not indicate the sample is analyte free but that the analyte is not detected at or above the PQL. AC77129Sample ID: NC DWR Laboratory Section Results/Sample Comments/Qualifier Definitions CAS #Analyte Name PQL Result/ Qualifier Units Method Reference Analysis Date Validated by J12 The calibration verification did not meet the calibration acceptance criterion for field parameters. J2 The reported value failed to meet the established quality control criteria for either precision or accuracy. J3 The sample matrix interfered with the ability to make any accurate determination. J4 The data is questionable because of improper laboratory or field protocols (e.g., composite sample was collected instead of grab, plastic instead of glass container, etc.). J5 Temperature limits exceeded (samples frozen or >6°C) during transport or not verifiable (e.g., no temperature blank provided): non-reportable for NPDES compliance monitoring. J6 The laboratory analysis was from an unpreserved or improperly chemically preserved sample. The data may not be accurate. J7 This qualifier is used to identify analyte concentration exceeding the upper calibration range of the analytical instrument/method. The reported value should be considered estimated. J8 Temperature limits exceeded (samples frozen or >6ºC) during storage, the data may not be accurate. J9 The reported value is determined by a one-point estimation rather than against a regression equation. The estimated concentration is less than the laboratory practical quantitation limit and greater than the laboratory method detection limit. M Sample and duplicate results are "out of control". The sample is non-homogenous (e.g., VOA soil). The reported value is the lower value of duplicate analyses of a sample. N1 Presumptive evidence and estimated value. The component has been tentatively identified base on mass spectral library. N2 There is an indication that the analyte is present, but quality control requirements for confirmation were not met (i.e., presence of analyte was not confirmed by alternate procedures). N3 This code shall be used if the level is too low to permit accurate quantification, but the estimated concentration is less than the laboratory practical quantitation limit and greater than the laboratory method detection limit. This code is not routinely N4 This code shall be used if the level is too low to permit accurate quantification, but the estimated concentration is less than the laboratory practical quantitation limit and greater than the instrument noise level. This code is used when an MDL has not N5 The component has been tentatively identified based on a retention time standard. P Elevated PQL* due to matrix interference and/or sample dilution. Q1 Holding time exceeded prior to receipt by lab. Q2 Holding time exceeded following receipt by lab. S Not enough sample provided to prepare and/or analyze a method-required matrix spike (MS) and/or matrix spike duplicate (MSD). U Indicates that the analyte was analyzed for but not detected above the reported practical quantitation limit*. The number value reported with the "U" qualifier is equal to the laboratory's practical quantitation limit*. U, J6 The laboratory analysis was from an unpreserved or improperly chemically preserved sample. The data may not be accurate. UU Indicates that the analyte was not detected by a screen analysis. The number value was determined by a one-point estimation at the PQL. V Indicates the analyte was detected in both the sample and the associated method blank. Note: The value in the blank shall not be subtracted from the associated samples. X1 Sample not screened for this compound. X2 Sampled, but analysis lost or not performed-field error. X3 Sampled, but analysis lost or not performed-lab error. Y Elevated PQL* due to insufficient sample size. Z1 Inability to analyze the sample. Z2 Questions concerning data reliability. WSS Chemistry Laboratory>> 1623 Mail Service Center, Raleigh, NC 27699-1623 (919) 733-3908 Page 4 of 4 "Not Detected" or "U" does not indicate the sample is analyte free but that the analyte is not detected at or above the PQL.