Loading...
HomeMy WebLinkAbout4501_Henderson_MSWLF_CDLF_LFG_FID1386441_20191213i pENR USE ONLY —]PaperReport ❑Electronic Data - Email CD (data loaded: Yes / No Doc/Event #: NC DENR I IEnvironmental Monitoring Division of Waste Management - Solid Waste Reporting Form Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Instructions: Prepare one form for each individually monitored unit. Please type or print legibly. Attach a notification table with values that attain or exceed NC 2L groundwater standards or NC 2B surface water standards. The notification must include a preliminary analysis of the cause and significance of each value. (e.g. naturally occurring, off -site source, pre-existing condition, etc.). Attach a notification table of any groundwater or surface water values that equal or exceed the reporting limits. Attach a notification table of any methane gas values that attain or exceed explosive gas levels. This includes any structures on or nearby the facility (NCAC 13B .1629 (4)(a)(i). Send the original signed and sealed form, any tables, and Electronic Data Deliverable to: Compliance Unit, NCDENR-DWM, Solid Waste Section, 1646 Mail Service Center, Raleigh, NC 27699-1646. Solid Waste Monitoring Data Submittal Information Name of entity submitting data (laboratory, consultant, facility owner): Golder Associates NC, Inc. on behalf of Henderson County Contact for questions about data formatting. Include data preparer's name, telephone number and E-mail address: Name: David Y. Reedy II Phone: 336-852-4903 E-mail: dreedy@golder.com NC Landfill Rule: Actual sampling dates (e.g., Facility name: Facility Address: Facility Permit # (.0500 or .1600) October 20-24, 2006) Henderson County Closed Landfill 191 Transfer Station Drive 45-01 .1600/.0500 December 5, 2019 Hendersonville, NC 28791 Environmental Status: (Check all that apply) Initial/Background Monitoring Detection Monitoring Assessment Monitoring Q Corrective Action of data submitted: (Check all that apply) Groundwater monitoring data from monitoring wells 0 Groundwater monitoring data from private water supply wells Leachate monitoring data ❑ Surface water monitoring data Methane gas monitoring data Corrective action data (specify) Other(specify) Notification attached? e No. No groundwater or surface water standards were exceeded. Yes, a notification of values exceeding a groundwater or surface water standard is attached. It includes a list of groundwater and surface water monitoring points, dates, analytical values, NC 2L groundwater standard, NC 2B surface water standard or NC Solid Waste GWPS and preliminary analysis of the cause and significance of any concentration. Yes, a notification of values exceeding an explosive methane gas limit is attached. It includes the methane monitoring points, dates, sample values and explosive methane gas limits. Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. Furthermore, I have attached complete notification of any sampling values meeting or exceeding groundwater standards or explosive gas levels, and a preliminary analysis of the cause and significance of concentrations exceeding groundwater standards. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. David Y. Reedy II, PG Senior Hydrogeologist Facili resentativ Nam rint) Title i z---/ Date Golder Associates NC, Inc., 5B Oak Branch Drive, Greensboro, NC 27407 Facility Representative Address C-2862 NC PE Firm License Number (if applicable effective May 1, 2009) Revised 6/2009 336-852-4903 (Area Code) Telephone Number Affix NC Licensed/ Professional Geologist Seal ll�m 9 55;3 13 7t"� o �k.x� ��a G GOLDER December 13, 2019 Ms. Jaclynne Drummond, Hydrogeologist North Carolina Department of Environmental Quality Division of Waste Management - Solid Waste Section 2090 US Highway 70 Swannanoa, North Carolina 28778 828-296-4706 jaclynne.drummond@ncdenr.gov METHANE MONITORING RESULTS — FOURTH QUARTERLY EVENT OF 2019 CLOSED HENDERSON COUNTY LANDFILL, PERMIT NO. 45-01 HENDERSON COUNTY, NORTH CAROLINA Dear Jackie, 19128179.202 Attached are the results from the December 5, 2019, fourth quarterly methane monitoring event conducted at the above -referenced facility. As shown on the attached Boundary Gas Probe Monitoring Log, methane was not detected above the lower explosive limit (LEL) in any compliance or assessment methane monitoring points during the event. No methane was detected in the facility structures during this compliance monitoring event. If you have any questions or concerns, please contact us at 336-852-4903. Sincerely, Golder Associates NC, Inc. David "Dusty" Y. Reedy II, PG Senior Hydrogeologist Golder Associates NC, Inc. 5B Oak Branch Drive, Greensboro, North Carolina, USA 27407 Engineering Lic. No. C-2862/Geology Lic. No. C-399 Rachel P. Kirkman, PG Associate and Senior Consultant T: +1 336 852-4903 F: +1 336 852-4904 Golder Associates NC, Inc. is a licensed user of the Golder trademark, and an associated operating entity. Golder and the G logo are trademarks of Golder Associates Corporation. golder.com Ms. Jaclynne Drummond, Hydrogeologist North Carolina Department of Environmental Quality CC: Marcus Jones, PE, Director of Engineering, Henderson County, 1 Historic Courthouse Square, Suite 6, Hendersonville, NC 28792. 828-694-6560. majones@hendersoncountync.org Greg Wiggins, Operations Manager, Henderson County, 191 Transfer Station Drive, Hendersonville, North Carolina 28791. 828-694-7982. gwiggins@hendersoncountync.org Attachments: Boundary Gas Probe Monitoring Log — December 5, 2019 Cut-off Trench LFG Vent Monitoring Log — December 5, 2019 Methane Monitoring Location Map Calibration Record gAprojects\henderson county\19128179\phase 202 - 4th qtr Ifg 2019\200 deliverables\252 final issued\19128179.202-r-001-rev0-4th_gtr_Ifg_rpt.docx 19128179.202 December 13, 2019 ' GOLDER NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: Thisform and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are available.lbr inspection and examination by any person upon request (NC General Statute 132-6). Facility Name: Henderson County Landfill Permit Number: 45-01 Sampling Date: 12/05/1 9 NC Landfill Rule (.0500 or.1600): Sample Collector Name & Position: E. Vasko Geologist Gas Meter Type & Serial Number: GEM 5000 Gas Meter Calibration Date: 0 1 / 1 0/ 1 9 Field Calibration Date & Time: 1 2/05/19 08:00 Field Calibration Gas Type (15115 or 35/50): 35/50 Field Calibration Gas Canister Expiration Date: 2/2 1 /21 Gas Meter Pump Rate: 300 cc/min Ambient Air Temperature: 52 0 F Barometric Pressure (in. or min Hg): 27.83 Weather Conditions: Clear Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office). Attach a test location map or drawing. Report methane readings as both % LEL and % CH4 by volume. Convert % CH4 (by volume) to % LEL as follows: % methane (by volume)/20 = % LEL. *Hydrogen Sulfide (H2S) gas monitoring may be required for Construction & Demolition Landfills (CDLFs). See individual permit conditions and/or Facility LFG monitoring plan. Location or LFG Well ID Sample Tube Purge Time of Day Time Pumped (sec) Initial �o LEL Stabilized %LEL % CH4 (volume) % 02 (volume) % CO2 (volume) % H2S" (volume) NOTES MP-1 13:19 60 2 2 0.1 14.0 5.5 1 MP-3 13:14 60 2 2 0.1 15.2 5.8 0 MP-4 13:08 60 2 2 0.1 10.8 7.5 0 MP-7 13:02 60 2 2 0.1 13.5 4.6 0 MP-8 12:53 60 4 4 0.2 19.3 0.1 0 MP-9 12:58 60 4 4 0.2 18.9 0.4 0 Activity Building 12:17 1 60 2 2 1 0.1 19.5 0.1 1 0 Animal Shelter 12:00 60 4 4 0.2 19.8 0.1 0 Break House 12:00 60 4 4 0.2 19.6 0.1 0 Bus Garage 13:22 60 4 4 0.2 19.8 0.1 0 Convenience Center 12:05 60 2 2 0.1 19.7 0.1 0 *The Landtec GEM 5000 has a Maintenance Shop 12:27 60 4 4 0.2 19.6 0.1 0 CH4 accuracy range of +/- 0.3% NOTE: 1f*needed, attach additional data.fbrms to include additional LFG monitoring data locationsfor thefacility. ACTION LEVELS: Methane: >1.25% by volume (inside structures) AND >5% by volume (at facility boundary) Hydrogen Sulfide: >l % by volume (inside structures) AND >4% by volume (at facility boundary) Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there are significant penalties for making any false statement, representation, or certification inVWing the o'bility of a fine and imprisonment. r Geologist SIGNATURE W 67 TITLE Revised - March 6, 2017 NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice. This,%rm and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are available fbr inspection and examination by any person upon request (NC General Statute 132-6). FacilityName: Henderson County Landfill Sampling Date:12/05/19 Sample Collector Name & Position: Number: 45-01 Landfill Rule (.0500 or.1600): E. Vasko Geologist Gas Meter Type & Serial Number: G E M 5000 Field Calibration Date & Time: 12/05/19 08:00 Gas Meter Calibration Date: 01 /10/19 Field Calibration Gas Type (15/15 or 35/50): 35/50 Field Calibration Gas Canister Expiration Date: 2/21 /21 Gas Meter Pump Rate: 300 cc/min Ambient Air Temperature: 520 F Barometric Pressure (in. or min Hg): 27.83 Weather Conditions: Clear Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office). Attach a test location map or drawing. Report methane readings as both % LEL and % CH4 by volume. Convert % CH4 (by volume) to % LEL as follows: % methane (by volume)/20 = % LEL. *Hydrogen Sulfide (H2S) gas monitoring may be required for Construction & Demolition Landfills (CDLFs). See individual permit conditions and/or Facility LFG monitoring plan. Location or LFG Well ID Sample Tube Purge Time of Day Time Pumped P (sec) Initial o /o LEL Stabilized /o LEL " % CH4 (volume) 0 /0 02 (volume) 0 /o CO2 (volume) 0 /o H2S (volume) NOTES Scalehouse 12:09 60 4 4 0.2 19.7 0.1 0 Trace Barn 12:33 60 2 2 0.1 19.7 0.1 0 MP-6 12:45 60 2 2 0.1 19.3 0.1 0 TR-2 12:50 60 60 60 3.0 14.7 6.7 0 TR-3 12:48 60 2 2 0.1 19.5 0.1 0 LFG-101 13:46 60 4 4 0.2 19.2 0.5 0 LFG-102 13:44 60 4 4 0.2 17.8 0.9 0 LFG-103 13:40 60 2 2 0.1 12.4 7.2 0 'The Landtec GEM 5000 has a CH4 accuracy range of +/- 0.3% NOTE: Ifneeded, attach additional data forms to include additional LFG monitoring data locations for the.facility. ACTION LEVELS: Methane: >1.25% by volume (inside structures) AND >5% by volume (at facility boundary) Hydrogen Sulfide: >1 % by volume (inside structures) AND >4% by volume (at facility boundary) Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there are significant penalties for making any false statement, representation, or certification incI ding th possibility of a fine and imprisonment. rU/ Geologist SIGNATURE TITLE Revised — March 6, 2017 NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: This.form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are available.fbr inspection and examination by any person upon request (NC General Statute 132-6). Facility Name: Henderson County Landfill Permit Number: 45-01 Sampling Date:12/05/19 Sample Collector Name & Position: E. Vasko Gas Meter Type & Serial Number: GEM 5000 Landfill Rule (.0500 or.1600): Geologist Field Calibration Date & Time: 12/05/19 08:00 Gas Meter Calibration Date: 01 /10/19 Field Calibration Gas Type (15115 or 3 5/50):35/50 Field Calibration Gas Canister Expiration Date: 2/21 /21 Gas Meter Pump Rate: 300 CC/min Ambient Air Temperature: 520 F Barometric Pressure (in. or min Hg): 27.83 Weather Conditions: Clear Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office). Attach a test location map or drawing. Report methane readings as both % LEL and % CH4 by volume. Convert % CH4 (by volume) to % LEL as follows: % methane (by volume)/20 = % LEL. *Hydrogen Sulfide (H2S) gas monitoring may be required for Construction & Demolition Landfills (CDLFs). See individual permit conditions and/or Facility LFG monitoring plan. Location or LFG Well ID Sample Tube Purge Time of Day Time Pumped P (sec) Initial o /o LEL Stabilized o /o LEL % CH4 (volume) 0 /0 02 (volume) 0 /o CO2 (volume) 0 /o H2S (volume) NOTES Cut-off Trench Vent 1 13:10 60 22 22 1.1 14.1 4.9 0 Cut-off Trench Vent 2 13:07 60 4 4 0.2 15.2 3.8 0 *The Landtec GEM 5000 has a CH4 accuracy range of +1- 0.3% NOTE: tf'needed, attach additional data,fbrms to include additional LFG monitoring data locations,for the facility. ACTION LEVELS: Methane: >1.25% by volume (inside structures) AND >5% by volume (at facility boundary) Hydrogen Sulfide: >1 % by volume (inside structures) AND >4% by volume (at facility boundary) Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there are significant penalties for making any false statement, representation, or certification inclu ing the possibility of a fine and imprisonment. r Geologist SIGNATURE TITLE Revised — March 6, 2017 r TRACE BARN EW 2 EW�EW a Q 1 ❑ Ci1T-OFF TRENCH VENT 2 - PA \ [ Alf 6 28 ❑2 W. ❑ 5 � u� V I 7 1 CLOT CUT-OFF TRENCH VENT 1 E Ew- 7 t E - , gEMOLI LANDFILL, CLO VI ATEMP 1 L DOSED C6 f 4 ' AST Hi E f o i �3 Ew - , ❑ to 1 r I LOSE e EANON , E / o MP-3 -45 W- w' P j ❑EW-I9 , ti dd❑ 199t r 4 PRIVAT ROPE LEGEND EXISTING 10 FT, CONTOUR EXISTING 2 FT. CONTOUR — - - — PROPERTY LINE — — — LIMITS OF WASTE STREAM BUFFER •'^^^^'^+ 7REELINE EXISTING ROAD FENCE -----,------ LFG COLLECTION PIPING ......... LFG CUT-OFF TRENCH Mw•8 COMPLIANCE MONITORING WELL s mw-1 NON COMPLIANCE MONITORING WELLS . MP-6 COMPLIANCE METHANE MONITORING WELLS A MP8 ASSESSMENT METHANE MONITORING WELLS ❑ BRA SURFACE WATER MONITORING POINT Q EVV-29 LFG EXTRACTION WELL CONVERTED TO PASSIVE VENTING NOTES 1. TOPOGRAPHIC CONTOUR INTERVAL = 2 FEET 2. COORDINATE SYSTEM IS N.C. STATE PLANE GRID. 3. TOPOGRAPHIC DIVIDING LINE DIVIDES THE SASE MAP TOPOGRAPHIC CONTOURS FROM LANDSAT TOPOGRAPHIC CONTOURS. LANDSATTOPOGRAPHICCONTOLRSHAVCASCONTOUR INTERVAL. 4. RECORDS WERE UNABLE TO BE LDCATED FOR LFG EXTRACTION WELLS EW-XI THROUGH EW-Xi AND WERE GIVEN IDENTIFICATION NAMES UNTIL SUCH TIME THAT RECORDS ARE FOUND. 5. LOCATION OF CCMFLIANCE METHANE MONITORING WELL MP-4 ISAPPROXIMATE. REFERENCE I. BASE MAP PROVIOEO BY CAMP DRESSER & MCKEE FROM PREVIOUS wATER QUALITY MONITORING REPORTS. 2. WELLS MP-?, MPS, AND MP-R WERE SURVEYED BY REGIONAL LAND SURVEYING. INC. ON JUNE 1 T. 2C T5. L SITELOCATIONAP N TO S D 150 300 SCALE FEET PRCJECT HENDERSON COUNTY HENDERSON COUNTY CLOSED MSVV AND C&D LANDFILL ����CLIENT ���::::::PERMIT#45-01 �_ONSULTANTPG C-399 YYYY-MM•DD 2G16.09.12 717— _ METHANE MONITORING LOCATION MAP �v PREPARED MAK s G a L D E R DESIGN DYR REVIEW DYR PROJECT No. DRAVUk- GOLDER ASSOCIATES NC, INC. APPROVED RPK 08396506 1 CERTIFICATION OF CALIBRATION ISSUED BY: QED Environmental Systems, Inc. Services Facility A& PJLA Date Of Calibration: January 10, 2019 Calibmtlon Certificate Number: G502124 10/35620 No. 66916 Page 1 of 2 Approved By Signatory QED Environmental Systems, Inc. Services Facility, 2355 Bishop Circle West, Dexter, MI 48130 www.qedenv.com John Parisho Laboratory Inspection Customer. GEOTECH ENVIRONMENTAL EQUIPMENT INC 2650 E 40TH AVE DENVER, CO 80205 USA Description: Gas Analyser Model: GEM5000 Serial Number: G502124 Accredited Results: Methane CH4 Certified Gas (%) Instrument Reading (%) Uncertainty(%) 5.0 4.9 0.42 15.0 15.0 0.66 50.0 49.5 1.03 Carbon Dioxide CO2 Certified Gas (%) Instrument Reading (%) Uncertainty(%) 5.0 4.8 0.43 15.0 14.7 0.71 50.0 49.7 1.19 Oxwen 02 Certified Gas (%) Instrument Reading (%) Uncertainty(%) 20.7 20.7 0.25 Gas cylinders are traceable and details can be provided if requested. CH4, CO2 readings recorded at: 32.4 °C/90.3 OF 02 readings recorded at: 23.8 °C/74.9 OF Barometric Pressure: 29.26 "Hg Method of Test: The analyzer is calibrated in a temperature controlled chamber using reference gases. All analyzers are calibrated in accordance with our procedure ISP-17 using high purity grade gas. All calibrations are performed in accordance with ISO 17025 at LANDTEC, an ISO 17025:2005 — accredited service facility through PJLA. The reported expanded uncertainty is based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95%. The uncertainty evaluation has been carried out in accordance with NIST requirements. The calibration results published in this certificate were obtained using equipment capable of producing results that are traceable through NIST to the International System of Units (SI). Certification only applies to results shown. This certificate may not be reproduced other than in full, except with the prior written approval of the issuing laboratory. UUMNANIST•1.1 CERTIFICATION OF CALIBRATION PJLA ACCREDITED CALIBRATION LABORATORY NO. 66916 Non Accredited results: Certificate Number G502124_10/35620 Page 2 of 2 Pressure Transducers inches of water column Transducer Certified (Low) Reading (Low) Certified (High) Reading (High) Accuracy Static 0" 0" 40" 39.90" 2.0" Differential 0" 0" 4" 3.90" 0.7" Barometer mbar Reference I Instrument Reading 0991 mbar / 29.26 "H 0992 mbar / 29.28 "H Additional Gas Cells Gas Certified Gas ( m) Instrument Readin ( m) CO H2S 501 249.50 508 250 End of Certificate LP015LNANIST• I.1 Standard: Standard: Instrument: Landtec Model: GEM 5000 Serial#: 19010 35% CO2 50% CH4 Calibration Standards Lot#: HR.1-399-1 Response: 34.9% Lot#: HR-1-299-1 Response: 50.1% Standard: 0.0% 02 Lot#: HBJ-399-1 Response: n nn% Standard: Lot#: Response: Service Performed By: KENNY C Date: 12/2/2019 Units performs within specifications: X Flow OK: X Battery OK: X Temperature: 70F Relative Humidity: 13% Comments: The calibration results published in this certificate were obtained using equipment capable of producing results that are traceable through MIST to the international System of Units (SI). Certification only applies to results shown. This certificate may not be reproduced other than in full, except with the prior written approval of the issuing laboratory. P.O. BOX 443. Snellville, Georgia 30078-0443 ZON t p�,F� 'gg,@ @@fi�gg 800-474-2490 770-978-9971 Fax: 770-978-8661.