Loading...
HomeMy WebLinkAbout6301_Moore_CDLF_MSWLF_LFG_FID1261716_20181127I pENR USE ONLY ❑Paper Report ❑Electronic Data - Email CD (data loaded: Yes / No Doe/Event #: NC DENR I IEnvironmental Monitoring Division of Waste Management - Solid Waste Reporting Form Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Instructions: Prepare one form for each individually monitored unit. Please type or print legibly. Attach a notification table with values that attain or exceed NC 2L groundwater standards or NC 2B surface water standards. The notification must include a preliminary analysis of the cause and significance of each value. (e.g. naturally occurring, off -site source, pre-existing condition, etc.). Attach a notification table of any groundwater or surface water values that equal or exceed the reporting limits. Attach a notification table of any methane gas values that attain or exceed explosive gas levels. This includes any structures on or nearby the facility (NCAC 13B .1629 (4)(a)(i). Send the original signed and sealed form, any tables, and Electronic Data Deliverable to: Compliance Unit, NCDENR-DWM, Solid Waste Section, 1646 Mail Service Center, Raleigh, NC 27699-1646. Solid Waste Monitoring Data Submittal Information Name of entity submitting data (laboratory, consultant, facility owner): Golder Associates NC, Inc. (on behalf of Moore County) Contact for questions about data formatting. Include data preparer's name, telephone number and E-mail address: Name: David "Dusty" Y. Reedy, PG Phone: 336-852-4903 E-mail: dreedy@golder.com NC Landfill Rule: Actual sampling dates (e.g., Facility name: Facility Address: Facility Permit # (.0500 or .1600) October 20-24, 2006) 456 Turning Leaf Way November 27-28, 2018 Moore County Landfill Aberdeen, NC 28315 63-01 .0500 December 7, 2018 Environmental Status: (Check all that apply) ❑ Initial/Background Monitoring ❑ Detection Monitoring Assessment Monitoring ❑X Corrective Action of data submitted: (Check all that apply) Groundwater monitoring data from monitoring wells XQ Methane gas monitoring data Groundwater monitoring data from private water supply wells Corrective action data (specify) Leachate monitoring data ❑ itoring data Other(specify) Surface water mon Notification attached? 8 No. No groundwater or surface water standards were exceeded. Yes, a notification of values exceeding a groundwater or surface water standard is attached. It includes a list of groundwater and surface water monitoring points, dates, analytical values, NC 2L groundwater standard, NC 2B surface water standard or NC Solid Waste GWPS and preliminary analysis of the cause and significance of any concentration. �X Yes, a notification of values exceeding an explosive methane gas limit is attached. It includes the methane monitoring points. dates, sample values and explosive methane gas limits. Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. Furthermore, I have attached complete notification of any sampling values meeting or exceeding groundwater standards or explosive gas levels, and a preliminary analysis of the cause and significance of concentrations exceeding groundwater standards. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. David "Dusty" Y. Reedy, PG Senior Hydrogeologist 336-852-4903 Facili esentativ/am � Title (Area Code) Telephone Number Affix NC Licensed/ Professional Geologist Seal Signature Golder Associates NC, Inc., 5B Oak Branch Drive, Greensboro, NC 27407 Facility Representative Address PE C-2862; PG C-399 NC PE Firm License Number (if applicable effective May 1, 2009) Revised 612009 2- N-/ Date ,�€066 November 2018 0739615018.200 kil GOLDER Project Name: Moore County Landfill Site Contact: JW Baucom Day 1: 11/27/2018 High Temperature: 47°F Starting Barometric Pressure: 29.3 in Ha Monitoring Equipment: GEM 2000+ Day 2: 1112812018 High Temperature: 44°F Starting Barometric Pressure: 29.4 in Ha Monitoring Equipment: GEM 2000+ Day 2: 1210712018 High Temperature: 50°F Starting Barometric Pressure: 29.4 in Ha Monitoring Equipment: GEM 2000+ BOUNDARY PROBE MONITORING LOG Project Number: 0739-615018.200 Technician(s): Erik Vasko & Travis Martinez Low Temperature: 46° F End Barometric Pressure: 29.2 in Ho Low Temperature: 40° F End Barometric Pressure: 29.4 in Ha Low Temperature: 50° F End Barometric Pressure: 29.4 in Ho DATE: 11/27-28 & 12/07/2018 Monitoring Point Date Time Methane (CHa) %Carbon Dioxide CO %Oxygen (%) H2S (ppm) Comments GP-9 11/28/18 13:59 0.0 0.0 21.5 0 1 inch well GP-10 11/28/18 13:42 0.3 0.3 20.5 0 1 inch well GP-11 11/28/18 14:35 0.0 1.2 20.1 0 1 inch well GP-12 11/28/18 14:19 0.0 0.3 20.8 0 1 inch well GP-13 11/28/18 12:55 0S 20A 0.0 0 1 inch well GP-13R 11/28/18 12:51 0.0 0.6 20.7 0 1 inch well GP-14 11/28/18 13:07 0.0 8A 12.5 0 1 inch well GP-14R 11/28/18 12:45 0.0 1.1 20.1 0 1 inch well GP-15 11/28/18 12:31 0.1 0.3 20.7 0 1 inch well GP-15R 11/28/18 12:39 0.0 1.2 20.5 0 1 inch well GP-16 11/28/18 15:13 0.0 2A 18.5 0 1 inch well GP-17 11/28/18 13:16 0.0 1.9 17.0 0 1 inch well MW-6 11/28/18 13:26 7.1 4.8 15.5 0 2inch groundwater well MW-15 11/28/18 13:32 8.1 9.9 9.2 0 2inch groundwater well GV-1 11/27/18 14:31 0.0 0.1 21.7 0 Gas vent GV-2 11/27/18 14:29 0.0 0.0 21.8 0 Gas vent GV-3 11/27/18 14:27 0.0 0.0 211 0 Gas vent GV-4 11/27/18 14:25 0.0 0.0 21.7 0 Gas vent GV-5 11/27/18 14:23 0.0 0.0 211 0 Gas vent GV-6 11/27/18 14:21 0.0 0.0 21.6 0 Gas vent GV-7 11/27/18 14:20 0.0 0.0 21.6 0 Gas vent GV-8 11/27/18 14:18 0.0 0.0 21.6 0 Gas vent GV-9 11/27/18 13:03 0.0 0.0 21.3 0 Gas vent GV-10 11/27/18 13:00 0.0 0.0 21.4 0 Gas vent GV-11 11/27/18 12:57 0.1 0.0 21.3 0 Gas vent GV-12 11/27/18 12:55 0.0 0.0 21.2 0 Gas vent GV-13 11/27/18 13:29 19.1 13.3 13.7 0 Gas vent GV-14 11/27/18 Gas vent GV-15 11/27/18 13:34 5.9 4.6 18.8 0 Gas vent GV-16 11/27/18 Gas vent GV-17 11/27/18 13:52 0.1 0.0 21.7 0 Gas vent GV-18 11/27/18 13:54 0.0 0.1 21.6 0 Gas vent GV-19 11/27/18 13:56 4.0 2.8 19.7 0 Gas vent GV-20 11/27/18 13:59 2.1 1.5 21.4 0 Gas vent GV-21 11/27/18 14:01 5.8 4.0 19.0 0 Gas vent GV-22 11/27/18 14:03 0.0 0.1 21.6 0 Gas vent GV-23 11/27/18 14:16 0.0 0.0 21.6 0 Gas vent GV-24 11/27/18 14:06 0.0 0.0 21.8 0 Gas vent GV-25 11/27/18 13:06 57.5 40.1 1.0 222 Gas vent GV-26 11/27/18 13:10 0.0 0.0 21.6 0 Gas vent GV-27 11/27/18 13:12 48.6 33.9 4.9 58 Gas vent GV-28 11/27/18 13:13 2.4 2.0 20.6 1 Gas vent GV-29 11/27/18 13:17 6.9 6.7 14.7 0 Gas vent GV-30 11/27/18 14:50 57.2 42.0 0.7 58 Passive LFG Gas vent well GV-31 11/27/18 14:41 56.5 36.7 2.4 164 Passive LFG Gas vent well GV-32 11/27/18 14:44 58.3 41.6 0.0 63 Passive LFG Gas vent well GV-33 Eastern Trench Vent 11/27/18 12:42 46.5 37.4 0.2 0 New LFG Trench Gas vent GV-34 Western Trench Vent 11/27/18 1242 1.4 1.4 20.2 0 New LFG Trench Gas vent Scalehouse 11/27/18 12:17 0.0 0.1 21.2 0 1 Building Maintenace Shop 12/07/18 13:41 0.0 0.2 21.4 0 Building Transfer Station 12/07/1 13:46 0.0 0.1 21.6 0 Buildin Blake Residence Crawl space) 1112711: 15:19 0.0 0.0 21.2 0 Building Completed by: Erik Vasko & Travis Martinez G:\PROJECTS\Moore County\0739615018 - Moore - Env Services\P200 - CH4 Mon & Reporting\200 DELIVERABLES\200 Draft Issued\202 Q4 November 2018\Aftachment A - Landfill Gas Probe Log.dsx LEGEND rn 0 0 0 rn co 0 O 45 E co z iL r C a aD C7 0 N PdROUND OBSCURED ` SEE ACCURACY NOTE 11 I.tss� PERENNIAL STREAM i — — INTERMITTENT STREAM — — — — — — — — — EPHEMERALSTREAM — POND AND WETLAND LIMITS EXISTING 10 FT GROUND SURFACE CONTOUR EXISTING 2 FT GROUND SURFACE CONTOUR PROPERTY LINE \ APPROXIMATE LIMITS OF WASTE EXISTING ROAD 385 POTENTIOMETRIC GROUNDWATER CONTOURS (5 FT. INTERVAL) GROUNDWATER FLOW SEGMENTS '388.96 MW-1 MONITORING D GROUNDWATER ELEVATION GP-10 METHANE PROBE AND IDENTIFICATION C ❑ SW-1 SURFACE WATER MONITORING POINT AND IDENTIFICATION 0 0 0 o ` LANDFILL GAS TRENCH VENTS AND IDENTIFICATION o 0 e9 PASSIVE LANDFILL GAS VENTS \ O PW-1 PRIVATE WELL LOCATION AND IDENTIFICATION O \� :.�� 4 WETLAND AREA N M NOT MEASURED SB-2 SOIL SAMPLE LOCATIONS PZ-1 EXISTING MONITORING WELLS 365.43 NOTES 1. TOPOGRAPHIC CONTOUR INTERVAL = 2 FEET 2. GROUNDWATER SURFACE CONTOUR INTERVAL = 5 FEET 3. GROUNDWATER ELEVATIONS MEASURED ON JUNE 20, 2018. 4. GROUNDWATER CONTOURS BASED ON LINEAR INTERPOLATION BETWEEN AND EXTRAPOLATION FROM KNOWN DATA, TOPOGRAPHIC CONTOURS, AND KNOWN FIELD CONDITIONS. THEREFORE, GROUNDWATER CONTOURS MAY NOT REFLECT ACTUAL CONDITIONS. 5. GROUNDWATER CONTOUR LINES SHOW THE WATER TABLE SHAPE AND ELEVATION. THESE CONTOURS ARE INFERRED LINES FOLLOWING THE GROUNDWATER SURFACE AT A CONSTANT ELEVATION ABOVE SEA LEVEL. THE GROUNDWATER FLOW DIRECTION IS GENERALLY PERPENDICULAR TO THE GROUNDWATER SURFACE CONTOURS, SIMILAR TO THE RELATIONSHIP BETWEEN SURFACE WATER FLOW AND TOPOGRAPHIC CONTOURS. 6. PROPERTY BOUNDARY SURVEY BY JAMES L. WRIGHT DATED NOVEMBER 1984. ITS LOCATION IS RELATIVE TO TOPOGRAPHY APPROXIMATE BY HDR ENGINEERING, INC. 7. EXISTING TOPOGRAPHY WITHIN ACTIVE AND PROPOSED LANDFILL PROVIDED BY MATTHEWS LAND SURVEYING & MAPPING, PLLC DATED APRIL 17, 2015. 8. MONITORING WELLS MW-1 THROUGH MW-5 SURVEYED JUNE 1987 BY S&ME, INC. MONITORING WELLS MW-6 THROUGH MW-16 SURVEYED APRIL 1995, SEPTEMBER 1996, AND APRIL 2003 BY HDR ENGINEERING INC./ ED BUCKNER RLS APRIL 17, 2015. MONITORING WELLS MW-11SR, MW- 11DR,MW- 15R, MW-17S, MW- 17P, MW- 18 AND PIEZOMETERS PZ-1, PZ-2 AND PZ-3 WERE SURVEYED BY FLEMING ENGINEERING, INC. ON JULY 3, 2018. 9. THE LOCATIONS OF LANDFILL GAS TRENCH VENTS ARE APPROXIMATE. 10. GROUNDWATER WELLS MW-11 D, MW-13D, AND MW-16D ARE NOT SCREENED IN THE SHALLOW AQUIFER AND ELEVATION DATA WERE NOT USED IN THE CONSTRUCTION OF GROUNDWATER CONTOURS. 11. A STREAM DETERMINATION WAS CONDUCTED ON APRIL 17, 2013 BY A GOLDER ASSOCIATES NC, INC. REPRESENTATIVE. THE STREAM DETERMINATION WAS CONDUCTED USING NCDWQ'S "METHODOLOGY FOR IDENTIFICATION OF INTERMITTENT AND PERENNIAL STREAMS AND THEIR ORIGINGS, VERSION 4.11". 12. THE WATER LEVEL FROM MW- 18 WAS NOT USED IN THE CONSTRUCTION OF GROUNDWATER CONTOURS AS IT WAS NOT YET STABILIZED. 0 200 400 SCALE FEET / CLIENT PROJECT j - MOORE COUNTY MOORE COUNTY LANDFILL -01 PERMIT NO. 63 ABERDEEN NORTH CAROLINA ,. •� O o \ r - �) !` jf1t�, CONSULTANT TITLE YYYY-MM-DD 2018-09-13 • / j'�'/� L..T� �n •'r ' if `J�f(f / \ PG C-399 GROUNDWATER SURFACE CONTOUR MAP I). j(' �7--'�.1i/;�c" � ,� : i ,'L _ A '� �� >, ���� r' �'•:.6�' '��rid' PREPARED KL JUNE 209 2018 DESIGN WBB GOLDER SITE LOCATION MAP REVIEW RPK PROJECT No. PHASE DRAWING NOT TO SCALE GOLDER ASSOCIATES NC, INC. APPROVED RPK 0739615018 100 0 INSTRUMENT CALIBRATION REPORT Pine Environmental Services LLC 8411 Garvey Drive, Suite 113 Raleigh, NC 27614 Toll -free: (866) 646-PINE (7463) Pine Environmental Services, Inc. Instrument ID 8665 Description Landtec GEM-2000 + Calibrated 11/26/2018 8:44:55AM Test Instruments Used During the Calibration Test Standard ID Description Manufacturer NC 4 GAS 20.9 NC 4 GAS 20.9 Gasco FBH-412-6 EX FBH-412-6 EX 5/19 5/ 19 NC 50/35 NC 50 CH4/35 CO2 Gasco MAP-399-5 1 /20 Notes about this calibration Calibration Result Calibration Successful Who Calibrated Ryan Williamson Serial Number / Model Number Lot Number 32211 FBH-412-6 GP 12126 - 31803 MAP-399-5 As Of Cal Entry Date Next Cal Date / Last Cal Date/ Expiration Date Opened Date 5/19/2019 1/20/2020 All instruments are calibrated by Pine Environmental Services LLC according to the manufacturer's specifications, but it is the customer's responsibility to calibrate and maintain this unit in accordance with the manufacturer's specifications and/or the customer's own specific needs. Notify Pine Environmental Services LLC of any defect within 24 hours of receipt of equipment Please call 800-301-9663 for Technical Assistance Pine Environmental Services LLC Windsor Industrial Park, 92 North Main Street, Bldg 20, Windsor, NJ 08561, 800-301-9663 www.pine-enviromnental.com INSTRUMENT CALIBRATION REPORT Pine Environmental Services LLC 8411 Garvey Drive, Suite 113 Raleigh, NC 27614 Toll -free: (866) 646-PINE (7463) Pine Environmental Services, Inc. Instrument 1D 8665 Description Landtec GEM-2000 + Calibrated 11/26/2018 8:44:55AM Manufacturer CES Landtec State Certified Model Number GEM2000+ Status Pass Serial Number/ Lot GM08581 Temp °C 21 Number Location North Carolina Humidity % 39 Department Calibration Specifications Group # 1 Range Ace % 0.0000 Group Name Methane Reading Ace % 3.0000 Stated Accy Pet of Reading Plus/Minus 0.00 Nom In Val / In Val In Type Out Val Out Type Fnd As Lft As Dev% Pass/Fail 50.00 / 50.00 %Volume 50.00 %Volume 49.00 50.00 0.00% Pass Group # 2 Range Ace % 0.0000 Group Name Carbon Dioxide Reading Ace % 3.0000 Stated Accy Pet of Reading Plus/Minus 0.00 Nom In Val / In Val In Type Out Val Out Type Fnd As Lft As Dev% Pass/Fail 35.00 / 35.00 %Volume 35.00 %Volume 34.70 35.00 0.00% Pass Group # 3 Range Ace % 0.0000 Group Name Oxygen Reading Ace % 3.0000 Stated Accy Pet of Reading Plus/Minus 0.00 Nom In Val / In Val In Type Out Val Out Type Fnd As Lft As Dev% Pass/Fail 20.90 / 20.90 %Volume 20.90 %Volune 20.70 20.90 0.00% Pass Group # 4 Range Ace % 0.0000 Group Name Hydrogen Sulfide Reading Ace % 3.0000 Stated Accy Pet of Reading Plus/Minus 0.00 Nom In Val / In Val In Type Out Val Out Type Fnd As Lft As Dev% Pass/Fail 25.00 / 25.00 PPM 25.00 PPM 28.00 25.00 0.00% Pass Group # 5 Range Ace % 0.0000 Group Name Carbon Monoxide Reading Ace % 3.0000 Stated Accy Pet of Reading Plus/Minus 0.00 Nom In Val / In Val In Type Out Val Out Tvve Fnd As Lft As Dev% Pass/Fail 50.00 / 50.00 PPM 50.00 PPM 48.00 50.00 0.00% Pass Pine Environmental Services LLC Windsor Industrial Park, 92 North Main Street, Bldg 20, Windsor, NJ 08561, 800-301-9663 www.pine-environmental.com