Loading...
HomeMy WebLinkAboutNCD003162542_Badin Business Park_Corrective Action_20181205 (2) Badin Business Park LLC c/o Alcoa Corporation 201 Isabella Street Suite 500 Pittsburgh, PA 15212-5858 USA Tel: 1 412 315 2900 December 5, 2018 Mr. Robert C. McDaniel Facility Management Branch Hazardous Waste Section North Carolina Department of Environmental Quality 217 West Jones Street Raleigh, North Carolina 27603 VIA ELECTRONIC MAIL Re: Investigative Report for the Little Mountain Creek Area Badin Business Park (f/k/a Alcoa - Badin Works) Badin, North Carolina EPA ID: NCD 003 162 542 Dear Mr. McDaniel: Badin Business Park LLC respectfully submits the above-referenced report for your review. The report is being provided as a condition of the April 2, 2018, Investigative Work Plan for the Phases 4 and 5 Corrective Measures Study, Alcoa/Badin Landfill, and Former Ball Field. Should you have any questions or comments, please contact Jason Mibroda of Alcoa at (412) 315-2783 at your convenience. Sincerely, Ronald M. Morosky Director, Corporate Remediation Enc. cc: Jason Mibroda, Alcoa Teresa Rodriguez, NCDEQ ENVIRONEERING, INC. INVESTIGATIVE REPORT FOR THE LITTLE MOUNTAIN CREEK AREA BADIN BUSINESS PARK FACILITY BADIN, NORTH CAROLINA December 5, 2018 Prepared for: Badin Business Park LLC 201 Isabella Street, Pittsburgh, PA 15212 Prepared by: ENVIRONEERING, INC. 16100 Cairnway, Suite 320 Houston, Texas 77084 832-674-8800 ENVIRONEERING, INC. 137-263 Little Mountain Creek Area Report – Badin Business Park Facility - Badin, NC; December 2018 i TABLE OF CONTENTS 1.0 INTRODUCTION .......................................................................................................................1 1.1 Site Overview ...................................................................................................................1 1.2 Scope of Work .................................................................................................................2 2.0 SAMPLING RESULTS ..............................................................................................................4 2.1 Little Mountain Creek Sediment Samples ....................................................................4 2.1.1 Polycyclic Aromatic Hydrocarbons ......................................................................4 2.1.2 Polychlorinated Biphenyls ....................................................................................4 2.2 Little Mountain Creek Surface Water Samples ...........................................................4 2.2.1 General Chemistry ................................................................................................4 2.2.2 Fluoride and Cyanide ............................................................................................5 2.2.3 Polychlorinated Biphenyls ....................................................................................5 2.2.4 Lead and Arsenic...................................................................................................5 2.2.5 Priority Pollutant Analysis ....................................................................................5 2.3 Eastern Drainage Ditch Sediment Samples ..................................................................6 2.3.1 Polycyclic Aromatic Hydrocarbons ......................................................................6 2.3.2 Polychlorinated Biphenyls ....................................................................................6 2.4 Eastern Drainage Ditch Surface Water Samples .........................................................6 2.4.1 Fluoride and Cyanide ............................................................................................6 2.4.2 Polycyclic Aromatic Hydrocarbons ......................................................................7 2.4.3 Polychlorinated Biphenyls ....................................................................................7 2.5 Field Blanks .....................................................................................................................7 3.0 CONCLUSIONS .........................................................................................................................27 LIST OF FIGURES Figure 2-1 Alcoa/Badin Landfill Sampling Locations ................................................................ 8 LIST OF TABLES Table 2-1 Little Mountain Creek Sediment Sample Analytical Results ................................................ 9 Table 2-2 Little Mountain Creek Sediment Sample Analytical Results (Congener Analysis) ............ 10 Table 2-3 Little Mountain Creek Surface Water Sample Analytical Results....................................... 12 Table 2-4 Little Mountain Creek Surface Water Sample Analytical Results (Congener Analysis) .... 13 Table 2-5 Little Mountain Creek Surface Water Sample Analytical Results (Priority Pollutant) ....... 15 Table 2-6 Eastern Drainage Ditch Sediment Sample Analytical Results ............................................. 17 Table 2-7 Eastern Drainage Ditch Sediment Sample Analytical Results (Congener Analysis) .......... 18 Table 2-8 Eastern Drainage Ditch Surface Water Sample Analytical Results ..................................... 20 Table 2-9 Eastern Drainage Ditch Surface Water Sample Analytical Results (Congener Analysis) ... 21 Table 2-10 Equipment Blank Sample Analytical Results ...................................................................... 23 Table 2-11 Equipment Blank Sample Analytical Results (Congener Analysis) .................................... 24 Table 2-12 Trip Blank Sample Analytical Results ................................................................................. 26 ENVIRONEERING, INC. 137-263 Little Mountain Creek Area Report – Badin Business Park Facility - Badin, NC; December 2018 ii LIST OF APPENDICES Appendix A Laboratory Reports and Chain of Custody Forms ENVIRONEERING, INC. 137-263 Little Mountain Creek Area Report – Badin Business Park Facility - Badin, NC; December 2018 1 1.0 INTRODUCTION The April 28, 2017 Investigative Work Plan for the Phase 4 and 5 Corrective Measures Study, Alcoa/Badin Landfill, and Former Ball Field (Work Plan) was developed as a guidance document in support of sampling and investigative activities at the Badin Business Park LLC, formerly known as the Alcoa Badin Works facility. The Work Plan was prepared following receipt of the North Carolina Department of Environmental Quality (NCDEQ) January 23, 2017 correspondence concerning the review of Phase 4 and 5 of the Corrective Measures Study (CMS), the Expanded Pre-CERCLIS Screening Assessment (EPSA) for the Former Ball Field, and the Site Inspection Report (SIR) for the Alcoa/Badin Landfill. NCDEQ determined that further evaluation was warranted and requested that a demonstration be made that identified items had been evaluated or prepare a work plan to evaluate those items. Select items were addressed in a March 3, 2017 written response and in a meeting with NCDEQ on March 28, 2017. On April 2, 2018, the Work Plan was revised incorporating requirements from the January 31, 2018 conditional approval letter and the instream monitoring study requirements of the September 29, 2017 Final NPDES Permit, Condition A. (8.). Implementation of the Work Plan began in April 2018. The approach for investigative activities was developed based on information obtained from site reconnaissance, previous investigations, and remedial activities conducted at the facility. The Work Plan was organized by the tasks:  Task 1 – Alcoa/Badin Landfill  Task 2 – Main Plant Area  Task 3 – Former Ball Field Area The scope of work for each of the tasks was summarized in Section 2 of the Work Plan. The following report details activities in support of Task 1, investigations at the Alcoa/Badin Landfill. 1.1 Site Overview The facility is located on State Highway 740 within the Town of Badin, North Carolina, and occupies approximately 123 acres of land. Production at the Badin Works facility began in 1916 and continued through 2002. Principal products once manufactured at the facility included carbon cathodes and anodes, continuous cast sheets, and specialty metals. The facility was permanently closed in 2010 and several buildings were razed in 2012. In 2016, the legal owner and operator of the facility transferred from Alcoa Inc. to the Badin Business Park LLC, a subsidiary Alcoa Corporation (Alcoa). The Alcoa/Badin Landfill and Little Mountain Creek Area is located across Wood Street immediately south of the facility. The facility is currently subject to Resource Conservation and Recovery Act (RCRA) Corrective Action as a condition of an existing RCRA Permit (EPA ID: NCD 003 162 542) as issued by the NCDEQ Division of Waste Management (DWM). As a condition of the permit, the facility is required to identify Solid Waste Management Units (SWMUs) and Areas of Concern (AOCs), assess the units for potential/confirmed releases, and provide remedies for those units where releases are identified and in need of corrective measures. To date, multiple investigations and interim measures have been completed across the facility. The RCRA Facility Investigation report identified groundwater in three areas of the facility as needing further actions. These areas were: groundwater at the Alcoa/Badin Landfill (SWMU ENVIRONEERING, INC. 137-263 Little Mountain Creek Area Report – Badin Business Park Facility - Badin, NC; December 2018 2 No. 2); groundwater at the Old Brick Landfill (SWMU No. 3); and groundwater at the Main Plant. More recently, the SIR for the Alcoa/Badin Landfill identified questions warranting further investigation and constituted a majority of the comments provided in the NCDEQ correspondence dated January 23, 2017. The facility is additionally subject to an existing National Pollutant Discharge Elimination System (NPDES) permit (NC0004308) as issued by the NCDEQ Division of Water Quality (DWQ). On September 29, 2017, the DWQ issued a permit renewal for the facility which included a request for an instream monitoring study of Little Mountain Creek. To satisfy the both NCDEQ requests, the April 2, 2018 Work Plan outlined activities to meet NCDEQ DWM and DWQ objectives. 1.2 Scope of Work In order to satisfy the objectives concerning the Alcoa/Badin Landfill and surrounding area, the scope of work was divided into four subtasks.  Subtask 1 – Surface Water Assessment: To determine the contribution of cyanide and fluoride compounds from the eastern drainage ditch to Little Mountain Creek and examine the potential source of the polychlorinated biphenyls (PCBs) and polycyclic aromatic hydrocarbons (PAHs) in and adjacent to the eastern drainage ditch, sediment and surface water samples were collected from the Eastern Drainage Ditch. To assess the variation on constituent levels in Little Mountain Creek as intended by the instream monitoring study requirements of the September 29, 2017 Final NPDES Permit Renewal, Condition A. (8.), sediment and surface water samples were collected from Little Mountain Creek.  Subtask 2 – Hydrological Conditions Evaluation: To address the objective of assessing the contribution of groundwater discharge to the eastern drainage ditch and evaluating the effects of the new trench collection system on the site-wide flow system and the constituent concentrations observed within the landfill interstitial pore water, the shallow groundwater unit, and the groundwater south of the landfill, an analysis of current hydrological conditions will be accomplished through monitoring water levels and constituent concentrations in several groundwater monitoring wells and piezometers. The scope of work for the Hydrological Conditions Evaluation subtask is currently in progress.  Subtask 3 – Geophysical Baseline Establishment: To address the objective of delineating the linear extent of elevated constituent levels in the wetland area downgradient of the Alcoa/Badin Landfill and monitor the effectiveness of the new trench collection system over an extended period of time, baseline conditions will be established by conducting quarterly geophysical surveys for a period of one year. The scope of work for the Geophysical Baseline Establishment subtask is currently in progress.  Subtask 4 – Jurisdictional Determination: To address the objective of determine the current jurisdictional status of the three drainage ditches (eastern, middle, and western) and adjacent areas, a stream and wetland delineation will be conducted to classify conditions at the base of the Alcoa/Badin Landfill. A Request for Preliminary Jurisdictional Determination summarizing the ENVIRONEERING, INC. 137-263 Little Mountain Creek Area Report – Badin Business Park Facility - Badin, NC; December 2018 3 findings of the delineation will be prepared for submission to the USACE. The scope of work for the Jurisdictional Determination subtask is currently in progress. Results from the completed Subtask 1, Surface Water Assessment are detailed below. Results from the Subtasks 2 through 4 will be submitted after completion of each respective subtask scope of work. ENVIRONEERING, INC. 137-263 Little Mountain Creek Area Report – Badin Business Park Facility - Badin, NC; December 2018 4 2.0 SAMPLING RESULTS To complete the Subtask 1 objectives concerning the Alcoa/Badin Landfill and surrounding area, surface water and sediment samples were collected from the Little Mountain Creek and the Eastern Drainage Ditch. Surface soil sample and sediment sample locations are presented on Figure 2-1. Sample collection, shipment, and decontamination followed procedures outlined in the April 2, 2018 Work Plan. Laboratory reports and completed chain of custody forms are provided in Appendix A. 2.1 Little Mountain Creek Sediment Samples To address the objective of assessing Little Mountain Creek sediments for constituents in excess of screening levels, two sediment samples (ABL-SD007-F005 and ABL-SD008-F005) and one duplicate sediment sample (ABL-SD007-D005) were collected from the sediment in Little Mountain Creek. Laboratory analytical results were compared against their respective EPA Freshwater Sediment Ecological Screening Value (ESV) values as obtained from the Region 4 Ecological Risk Assessment Supplemental Guidance - March 2018 Update. Sediment sample analytical results are summarized in Tables 2-1 and 2-2. 2.1.1 Polycyclic Aromatic Hydrocarbons Concentrations of PAHs were below the applicable EPA ESV values in all three samples. PAHs were detected in only one of the three samples (ABL-SD007-D005) but not the duplicate sample (ABL-SD007-F005). 2.1.2 Polychlorinated Biphenyls PCB Aroclors were not detected in any of the samples at concentrations above laboratory detection limits. The sum of the detected PCB congener concentrations were below EPA ESV values in all three samples. PCB congeners were detected at concentrations above laboratory detection limits in one of the three samples (ABL-SD007-F005) but not the duplicate sample (ABL-SD007-D005). 2.2 Little Mountain Creek Surface Water Samples To address the objective of assessing the potential for constituents in excess of water quality standards in Little Mountain Creek, five surface water samples (ABL-SW008-F005 through ABL-SW012-F005) and one duplicate surface water sample (ABL-SW008-D005) were collected from Little Mountain Creek. Laboratory analytical results were compared against their respective NCDEQ 15A North Carolina Administrative Code (NCAC) 2B Water Quality Standards for Surface Waters applicable to Freshwater Water Supply Classifications (WS-I to WS-V). Little Mountain Creek is currently classified by the State of North Carolina as Water Supply IV (WS-IV). Water Supply IV waters are also protected for Class C uses. Surface water sample analytical results are summarized in Tables 2-3 through 2-5. 2.2.1 General Chemistry ENVIRONEERING, INC. 137-263 Little Mountain Creek Area Report – Badin Business Park Facility - Badin, NC; December 2018 5 Laboratory analytical results indicated pH ranged from 7.04 to 7.55 and were within the applicable 15A NCAC 2B range. Hardness was found to be ranging from 36.0 to 39.2 mg/l in all the samples, below the 15A NCAC2B standard of 100 mg/l. 2.2.2 Fluoride and Cyanide Fluoride concentrations were below applicable 15A NCAC 2B standards in all samples. The concentrations were reported as estimated, or “J” flagged annotation, which means the result is less than the reporting limit but greater than or equal to the method detection limit, and the concentration is approximated. Concentrations of fluoride detected at the upstream location (ABL-SW012-F005 at 0.082J) were similar to concentrations detected at the downstream location (ABL-SW008-F005 at 0.088J and ABL-SW008-D005 at 0.087J). Total cyanide was not detected in any of the samples at concentrations above laboratory detection limits. 2.2.3 Polychlorinated Biphenyls PCB Aroclors were not detected in any of the samples at concentrations above laboratory detection limits. The sum of the detected PCB congeners concentrations was reported above the 15A NCAC 2B criteria of one part per trillion (ppt) in one location (ABL-SW008-F005); however, congeners were not detected in the duplicate sample (ABL-SW008-F005). 2.2.4 Lead and Arsenic Arsenic was not detected above the laboratory detection limit in any of the samples. Concentrations of lead were reported below the applicable 15A NCAC 2B criteria in all the samples. Lead was reported as estimated, or “J” flagged annotation, in one of the five samples (ABL-SW008-F005) but was not detected in the duplicate sample (ABL-SW008-D005). 2.2.5 Priority Pollutant Analysis To satisfy additional requirements of the NCDEQ DWR, three additional surface water samples were collected from Little Mountain Creek and analyzed for the presence of the 40 Code of Federal Regulations (CFR) 423 Appendix A Priority Pollutants. Volatile organic compounds, metals, phenols, cyanide, pesticides, PCBs, and dioxins were not detected in any of the samples at concentrations above the method detection limits. Semi-volatile Priority Pollutant organic compounds were reported below the applicable 15A NCAC 2B standards for the individual analytes; however, two samples (ABL-SW008-F005 and its duplicate ABL-SW008-D005) contained concentrations of total PAHs, a subset of the semi-volatile Priority Pollutant organic compound list, exceeding 15A NCAC 2B standards. Total PAHs is derived from a sum of detections for benzo(a)anthracene, benzo(a)pyrene, benzo(b)fluoranthene, benzo(k)fluoranthene, chrysene, dibenz(a,h)anthracene, and indeno(1,2,3-cd)pyrene. ENVIRONEERING, INC. 137-263 Little Mountain Creek Area Report – Badin Business Park Facility - Badin, NC; December 2018 6 2.3 Eastern Drainage Ditch Sediment Samples To address the objective of assessing the Eastern Drainage Ditch sediments for constituents in excess of screening levels, three sediment samples (ABL-SD010-F005 through ABL-SD012-F005) were collected from the sediment in the upper, middle, and lower sections of the Eastern Drainage Ditch. Laboratory analytical results were compared against their respective EPA Freshwater Sediment ESV values as obtained from the Region 4 Ecological Risk Assessment Supplemental Guidance - March 2018 Update. Sediment sample analytical results are summarized in Tables 2-6 and 2-7. 2.3.1 Polycyclic Aromatic Hydrocarbons Concentrations of acenaphthene, benzo(a)anthracene, benzo(a)pyrene, benzo(b)fluoranthene, chrysene, phenanthrene, pyrene, total high molecular weight PAHs, and total PAHs exceeded the applicable EPA ESV values in one (ABL-SD011-D005, i.e., middle location) of the three samples. No other PAHs were detected above EPA ESV values. 2.3.2 Polychlorinated Biphenyls PCB Aroclors were not detected in any of the samples at concentrations above laboratory detection limits. PCB congeners were detected in all three sample locations. At the upper ditch location (ABL-SD012-F005, i.e., nearest the Alcoa/Badin Landfill), the sum of the congener concentrations was below both the non-wildlife and wildlife EPA ESV values. The sum of PCB congeners detected in middle ditch location (ABL-SD011-F005) was above both the non-wildlife and wildlife EPA ESV values. The sum of PCB congeners detected in the lower ditch location (ABL-SD010-F005) was below the EPA non-wildlife ESV value, but above the EPA wildlife ESV value. 2.4 Eastern Drainage Ditch Surface Water Samples To address the objective of assessing Eastern Drainage Ditch surface water for constituents in excess of water quality standards, three surface water samples (ABL-SW013-F005 through ABL-SW015-F005) were collected from the surface water in the Eastern Drainage Ditch. The Eastern Drainage Ditch is believed to be a man-made drainage structure and currently not assigned a surface water classification by the State of North Carolina. For the purposes of evaluation, analytical results were compared against their respective NCDEQ 15A NCAC 2B Water Quality Standards for Surface Waters applicable to Class C waters. Surface water sample analytical results are summarized in Tables 2-8 and 2-9. 2.4.1 Fluoride and Cyanide Laboratory analytical results indicated concentrations of fluoride in two of the three samples at concentrations above the 15A NCAC 2B standards, however the downstream sample and the sample closest to Little Mountain Creek (ABL-SW013-F005) was below the 15A NCAC 2B standard. Total cyanide was detected in all three samples at concentrations above the 15A NCAC 2B standard. The three samples were additionally analyzed by method OIA 1677-09 for available cyanide, which includes ENVIRONEERING, INC. 137-263 Little Mountain Creek Area Report – Badin Business Park Facility - Badin, NC; December 2018 7 free cyanide and easily dissociated forms. Concentrations of available cyanide were below the EPA’s National Recommended Water Quality Criteria chronic value for free cyanide. 2.4.2 Polycyclic Aromatic Hydrocarbons PAHs were not detected in any of the samples at concentrations above laboratory detection limits. 2.4.3 Polychlorinated Biphenyls PCB Aroclors were not detected in any of the samples at concentrations above laboratory detection limits. The sums of the detected PCB congener concentrations were reported above the 15A NCAC 2B Surface Water Standard for total PCBs in all three samples. The total PCB concentrations was lowest at the upper ditch sampling location (i.e., closest to the Alcoa/Badin Landfill) and greatest at the lower ditch sampling location (i.e., closest to Little Mountain Creek). 2.5 Field Blanks One equipment blank was analyzed as part of this project. The equipment blank was prepared by running analyte free distilled water across sample collection equipment (trowel and bowl) after decontamination and placing it in the appropriate sample containers for analysis. Results are summarized in Tables 2-10 and 2-11. No concentrations of any constituents were detected above laboratory detection limits. One trip blank was analyzed as part of this project. The trip blank was prepared by the laboratory and placed in the cooler containing samples selected for VOC analysis. Results are summarized in Table 2-12. No concentrations of any constituents were detected above laboratory detection limits. Table 2-1 Little Mountain Creek Sediment Sample Analytical Results Alcoa/Badin Landfill Badin Business Park Facility Badin, North Carolina Sample ID Method CAS Units EPA Freshwater Sediment Ecological Screening Value (ESV)ABL-SD007-F005ABL-SD007-D005ABL-SD008-F005Location Depth Date Time Percent Moisture ASTM D2974-87 % PCB-1016 (Aroclor 1016)EPA 8082 12674-11-2 mg/kg ND 0.0172 ND 0.0167 ND 0.0191 NE PCB-1221 (Aroclor 1221)EPA 8082 11104-28-2 mg/kg ND 0.0172 ND 0.0167 ND 0.0191 NE PCB-1232 (Aroclor 1232)EPA 8082 11141-16-5 mg/kg ND 0.0172 ND 0.0167 ND 0.0191 NE PCB-1242 (Aroclor 1242)EPA 8082 53469-21-9 mg/kg ND 0.0172 ND 0.0167 ND 0.0191 NE PCB-1248 (Aroclor 1248)EPA 8082 12672-29-6 mg/kg ND 0.0172 ND 0.0167 ND 0.0191 NE PCB-1254 (Aroclor 1254)EPA 8082 11097-69-1 mg/kg ND 0.0172 ND 0.0167 ND 0.0191 NE PCB-1260 (Aroclor 1260)EPA 8082 11096-82-5 mg/kg ND 0.0172 ND 0.0167 ND 0.0191 NE Total Polychlorinated Biphenyls 1336-36-3 mg/kg 0.0598 1-Methylnaphthalene EPA 8270 90-12-0 mg/kg ND 0.0014 ND 0.0013 ND 0.0016 0.141 2-Methylnaphthalene EPA 8270 91-57-6 mg/kg ND 0.0012 ND 0.0012 ND 0.0014 0.0202 Acenaphthene EPA 8270 83-32-9 mg/kg ND 0.0017 ND 0.0020 0.0067 Acenaphthylene EPA 8270 208-96-8 mg/kg ND 0.0015 ND 0.0014 ND 0.0017 0.0059 Anthracene EPA 8270 120-12-7 mg/kg ND 0.0016 ND 0.0018 0.057 Benzo(a)anthracene EPA 8270 56-55-3 mg/kg ND 0.00080 ND 0.00093 0.108 Benzo(a)pyrene EPA 8270 50-32-8 mg/kg ND 0.0012 ND 0.0014 0.15 Benzo(b)fluoranthene EPA 8270 205-99-2 mg/kg ND 0.00076 ND 0.00088 0.19 Benzo(g,h,i)perylene EPA 8270 191-24-2 mg/kg ND 0.0029 ND 0.0034 0.17 Benzo(k)fluoranthene EPA 8270 207-08-9 mg/kg ND 0.0017 ND 0.0020 0.24 Chrysene EPA 8270 218-01-9 mg/kg ND 0.0020 ND 0.0024 0.166 Dibenz(a,h)anthracene EPA 8270 53-70-3 mg/kg ND 0.0020 ND 0.0024 0.033 Fluoranthene EPA 8270 206-44-0 mg/kg ND 0.00094 ND 0.0011 0.423 Fluorene EPA 8270 86-73-7 mg/kg ND 0.0018 ND 0.0021 0.077 Indeno(1,2,3-cd)pyrene EPA 8270 193-39-5 mg/kg ND 0.0032 ND 0.0037 0.2 Naphthalene EPA 8270 91-20-3 mg/kg ND 0.0026 ND 0.0025 ND 0.0030 0.176 Phenanthrene EPA 8270 85-01-8 mg/kg ND 0.0017 ND 0.0020 0.204 Pyrene EPA 8270 129-00-0 mg/kg ND 0.0020 ND 0.0024 0.195 Total Low Molecular Weight PAHs 0.6 Total High Molecular Weight PAHs 1 Total Polycyclic Aromatic Hydrocarbons 1.61 ND - The analyte was not detected above laboratory detection limits. Subscript indicates compound-specific MDL in mg/kg. J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit. ESV derived from Region 4 Ecological Risk Assessment Supplemental Guidance - March 2018 Update NE - Not established. ND ND ND 0.035 0.2857 NDND ND 0.2966 ND 0.0241 0.0378 0.0021 J 0.0148 0.0047 J 0.0433 0.0149 0.0276 0.0422 0.0161 ND 0.0280 0.0322 0.0028 J 0.0060 J 11.2 9.1 ND 22.6 7/12/2018 7/12/2018 7/12/2018 8:35 8:40 12:30 Downstream LMC Downstream LMC Upstream LMC Surface Surface Surface Table 2-2 Little Mountain Creek Sediment Sample Analytical Results - Congener Analysis Alcoa/Badin Landfill Badin Business Park Facility Badin, North Carolina Sample ID Congener Number IUPAC Name Method CAS Units EPA Freshwater Sediment Ecological Screening Value (ESV)ABL-SD007-F005ABL-SD07-D005ABL-SD008-F005Location Depth Date Time 2-MoCB 1 2-Chlorobiphenyl EPA 1668A 2051-60-7 mg/kg ND 0.0000243 ND 0.000025 ND 0.0000243 NE 3-MoCB 2 3-Chlorobiphenyl EPA 1668A 2051-61-8 mg/kg ND 0.0000243 ND 0.000025 ND 0.0000243 NE 4-MoCB 3 4-Chlorobiphenyl EPA 1668A 2051-62-9 mg/kg ND 0.0000243 ND 0.000025 ND 0.0000243 NE 2,2'-DiCB 4 2,2'-Dichlorobiphenyl EPA 1668A 13029-08-8 mg/kg ND 0.0000243 ND 0.000025 ND 0.0000243 NE 2,6-DiCB 10 2,6-Dichlorobiphenyl EPA 1668A 33146-45-1 mg/kg ND 0.0000243 ND 0.000025 ND 0.0000243 NE 2,5-DiCB 9 2,5-Dichlorobiphenyl EPA 1668A 34883-39-1 mg/kg ND 0.0000243 ND 0.000025 ND 0.0000243 NE 2,4-DiCB 7 2,4-Dichlorobiphenyl EPA 1668A 33284-50-3 mg/kg ND 0.0000243 ND 0.000025 ND 0.0000243 NE 2,3'-DiCB 6 2,3'-Dichlorobiphenyl EPA 1668A 25569-80-6 mg/kg ND 0.0000243 ND 0.000025 ND 0.0000243 NE 2,3-DiCB 5 2,3-Dichlorobiphenyl EPA 1668A 16605-91-7 mg/kg ND 0.0000243 ND 0.000025 ND 0.0000243 NE 2,4'-DiCB 8 2,4'-Dichlorobiphenyl EPA 1668A 34883-43-7 mg/kg ND 0.0000243 ND 0.000025 ND 0.0000243 NE 3,5-DiCB 14 3,5-Dichlorobiphenyl EPA 1668A 34883-41-5 mg/kg ND 0.0000243 ND 0.000025 ND 0.0000243 NE 3,3'-DiCB 11 3,3'-Dichlorobiphenyl EPA 1668A 2050-67-1 mg/kg ND 0.000238 ND 0.000245 ND 0.000238 NE (12/13)12/13 NA (Co-elution)EPA 1668A E52450566 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE 4,4'-DiCB 15 4,4'-Dichlorobiphenyl EPA 1668A 2050-68-2 mg/kg ND 0.000032 ND 0.000033 ND 0.0000321 NE 2,2',6-TrCB 19 2,2',6-Trichlorobiphenyl EPA 1668A 38444-73-4 mg/kg ND 0.0000243 ND 0.000025 ND 0.0000243 NE (18/30)18/30 NA (Co-elution)EPA 1668A E52450574 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE 2,2',4-TrCB 17 2,2',4-Trichlorobiphenyl EPA 1668A 37680-66-3 mg/kg ND 0.0000243 ND 0.000025 ND 0.0000243 NE 2,3',6-TrCB 27 2,3',6-Trichlorobiphenyl EPA 1668A 38444-76-7 mg/kg ND 0.0000243 ND 0.000025 ND 0.0000243 NE 2,3,6-TrCB 24 2,3,6-Trichlorobiphenyl EPA 1668A 55702-45-9 mg/kg ND 0.0000243 ND 0.000025 ND 0.0000243 NE 2,2',3-TrCB 16 2,2',3-Trichlorobiphenyl EPA 1668A 38444-78-9 mg/kg ND 0.0000243 ND 0.000025 ND 0.0000243 NE 2,4',6-TrCB 32 2,4',6-Trichlorobiphenyl EPA 1668A 38444-77-8 mg/kg ND 0.000025 ND 0.0000243 NE 2,3',5'-TrCB 34 2,3',5'-Trichlorobiphenyl EPA 1668A 37680-68-5 mg/kg ND 0.0000243 ND 0.000025 ND 0.0000243 NE 2,3,5-TrCB 23 2,3,5-Trichlorobiphenyl EPA 1668A 55720-44-0 mg/kg ND 0.0000243 ND 0.000025 ND 0.0000243 NE (26/29)26/29 NA (Co-elution)EPA 1668A E52450608 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE 2,3',4-TrCB 25 2,3',4-Trichlorobiphenyl EPA 1668A 55712-37-3 mg/kg ND 0.0000243 ND 0.000025 ND 0.0000243 NE 2,4',5-TrCB 31 2,4',5-Trichlorobiphenyl EPA 1668A 16606-02-3 mg/kg ND 0.00013 ND 0.000126 NE (20/28)20/28 NA (Co-elution)EPA 1668A E52450582 mg/kg ND 0.000129 ND 0.000125 NE (21/33)21/33 NA (Co-elution)EPA 1668A E52450590 mg/kg ND 0.000131 ND 0.000135 ND 0.000131 NE 2,3,4'-TrCB 22 2,3,4'-Trichlorobiphenyl EPA 1668A 38444-85-8 mg/kg ND 0.0000922 ND 0.000095 ND 0.0000923 NE 3,3',5-TrCB 36 3,3',5-Trichlorobiphenyl EPA 1668A 38444-87-0 mg/kg ND 0.0000243 ND 0.000025 ND 0.0000243 NE 3,4',5-TrCB 39 3,4',5-Trichlorobiphenyl EPA 1668A 38444-88-1 mg/kg ND 0.0000243 ND 0.000025 ND 0.0000243 NE 3,4,5-TrCB 38 3,4,5-Trichlorobiphenyl EPA 1668A 53555-66-1 mg/kg ND 0.0000243 ND 0.000025 ND 0.0000243 NE 3,3',4-TrCB 35 3,3',4-Trichlorobiphenyl EPA 1668A 37680-69-6 mg/kg ND 0.0000243 ND 0.000025 ND 0.0000243 NE 3,4,4'-TrCB 37 3,4,4'-Trichlorobiphenyl EPA 1668A 38444-90-5 mg/kg ND 0.000053 ND 0.0000515 NE 2,2',6,6'-TeCB 54 2,2',6,6'-Tetrachlorobiphenyl EPA 1668A 15968-05-5 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE (50/53)50/53 NA (Co-elution)EPA 1668A E52450657 mg/kg ND 0.0000971 ND 0.0001 ND 0.0000971 NE (45/51)45/51 NA (Co-elution)EPA 1668A E52450632 mg/kg ND 0.0000971 ND 0.0001 ND 0.0000971 NE 2,2',3,6'-TeCB 46 2,2',3,6'-Tetrachlorobiphenyl EPA 1668A 41464-47-5 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE 2,2',5,5'-TeCB 52 2,2',5,5'-Tetrachlorobiphenyl EPA 1668A 35693-99-3 mg/kg ND 0.000154 ND 0.00015 NE 2,3',5',6-TeCB 73 2,3',5',6-Tetrachlorobiphenyl EPA 1668A 74338-23-1 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE 43/73 43/73 NA (Co-elution)EPA 1668A mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE (49/69)49/69 NA (Co-elution)EPA 1668A E52450640 mg/kg ND 0.0001 ND 0.0000971 NE 2,2',4,5-TeCB 48 2,2',4,5-Tetrachlorobiphenyl EPA 1668A 70362-47-9 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE (44/47/65)44/47/65 NA (Co-elution)EPA 1668A E52450624 mg/kg ND 0.00015 ND 0.000146 NE (59/62/75)59/62/75 NA (Co-elution)EPA 1668A E52450665 mg/kg ND 0.000146 ND 0.00015 ND 0.000146 NE 2,2',3,4'-TeCB 42 2,2',3,4'-Tetrachlorobiphenyl EPA 1668A 36559-22-5 mg/kg ND 0.00005 ND 0.0000486 NE (40/41/71)40/41/71 NA (Co-elution)EPA 1668A E52450616 mg/kg ND 0.000146 ND 0.00015 ND 0.000146 NE 2,3,4',6-TeCB 64 2,3,4',6-Tetrachlorobiphenyl EPA 1668A 52663-58-8 mg/kg ND 0.00005 ND 0.0000486 NE 2,3',5,5'-TeCB 72 2,3',5,5'-Tetrachlorobiphenyl EPA 1668A 41464-42-0 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE 2,3',4,5'-TeCB 68 2,3',4,5'-Tetrachlorobiphenyl EPA 1668A 73575-52-7 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE 2,3,3',5-TeCB 57 2,3,3',5-Tetrachlorobiphenyl EPA 1668A 70424-67-8 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE 2,3,3',5'-TeCB 58 2,3,3',5'-Tetrachlorobiphenyl EPA 1668A 41464-49-7 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE 2,3',4,5-TeCB 67 2,3',4,5-Tetrachlorobiphenyl EPA 1668A 73575-53-8 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE 2,3,4',5-TeCB 63 2,3,4',5-Tetrachlorobiphenyl EPA 1668A 74472-34-7 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE (61/70/74/76)60/70/74/76 NA (Co-elution)EPA 1668A E52450673 mg/kg ND 0.0002 ND 0.000194 NE 2,3',4,4'-TeCB 66 2,3',4,4'-Tetrachlorobiphenyl EPA 1668A 32598-10-0 mg/kg ND 0.000084 ND 0.0000816 NE 2,3,3',4-TeCB 55 2,3,3',4-Tetrachlorobiphenyl EPA 1668A 74338-24-2 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE 2,3,3',4'-TeCB 56 2,3,3',4'-Tetrachlorobiphenyl EPA 1668A 41464-43-1 mg/kg ND 0.00005 ND 0.0000486 NE 2,3,4,4'-TeCB 60 2,3,4,4'-Tetrachlorobiphenyl EPA 1668A 33025-41-1 mg/kg ND 0.00005 ND 0.0000486 NE 3,3',5,5'-TeCB 80 3,3',5,5'-Tetrachlorobiphenyl EPA 1668A 33284-52-5 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE 3,3',4,5'-TeCB 79 3,3',4,5'-Tetrachlorobiphenyl EPA 1668A 41464-48-6 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE 3,3',4,5-TeCB 78 3,3',4,5-Tetrachlorobiphenyl EPA 1668A 70362-49-1 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE 3,4,4',5-TeCB 81 3,4,4',5-Tetrachlorobiphenyl EPA 1668A 70362-50-4 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE 3,3',4,4'-TeCB 77 3,3',4,4'-Tetrachlorobiphenyl EPA 1668A 32598-13-3 mg/kg ND 0.00005 ND 0.0000486 NE 2,2',4,6,6'-PeCB 104 2,2',4,6,6'-Pentachlorobiphenyl EPA 1668A 56558-16-8 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE 2,2',3,6,6'-PeCB 96 2,2',3,6,6'-Pentachlorobiphenyl EPA 1668A 73575-54-9 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE 2,2',4,5',6-PeCB 103 2,2',4,5',6-Pentachlorobiphenyl EPA 1668A 60145-21-3 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE 2,2',3,5,6'-PeCB 94 2,2',3,5,6'-Pentachlorobiphenyl EPA 1668A 73575-55-0 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE 2,2',3,5',6-PeCB 95 2,2',3,5',6-Pentachlorobiphenyl EPA 1668A 38379-99-6 mg/kg ND 0.000095 ND 0.0000923 NE (93/98/100/102)93/98/100/102 NA (Co-elution)EPA 1668A mg/kg ND 0.000194 ND 0.0002 ND 0.000194 NE (88/91)88/91 NA (Co-elution)EPA 1668A E52450715 mg/kg ND 0.0000971 ND 0.0001 ND 0.0000971 NE 2,2',3,3',6-PeCB 84 2,2',3,3',6-Pentachlorobiphenyl EPA 1668A 52663-60-2 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE 2,2',3,4,6'-PeCB 89 2,2',3,4,6'-Pentachlorobiphenyl EPA 1668A 73575-57-2 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE 2,3',4,5',6-PeCB 121 2,3',4,5',6-Pentachlorobiphenyl EPA 1668A 56558-18-0 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE 2,2',3,5,5'-PeCB 92 2,2',3,5,5'-Pentachlorobiphenyl EPA 1668A 52663-61-3 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE (90/101/113)90/101/113 NA (Co-elution)EPA 1668A E52450723 mg/kg ND 0.00015 ND 0.000146 NE 2,2',3,3',5-PeCB 83 2,2',3,3',5-Pentachlorobiphenyl EPA 1668A 60145-20-2 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE 2,2',4,4',5-PeCB 99 2,2',4,4',5-Pentachlorobiphenyl EPA 1668A 38380-01-7 mg/kg ND 0.00005 ND 0.0000486 NE 2,3,3',5,6-PeCB 112 2,3,3',5,6-Pentachlorobiphenyl EPA 1668A 74472-36-9 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE (86/87/97/108/119/125)86/87/97/108/119'125 NA (Co-elution)EPA 1668A E52450707 mg/kg ND 0.000291 ND 0.0003 ND 0.000291 NE (85/117/116)85/117/116 NA (Co-elution)EPA 1668A E52450699 mg/kg ND 0.000146 ND 0.00015 ND 0.000146 NE (110/115)110/115 NA (Co-elution)EPA 1668A E52450756 mg/kg ND 0.0001 ND 0.0000971 NE 2,2',3,3',4-PeCB 82 2,2',3,3',4-Pentachlorobiphenyl EPA 1668A 52663-62-4 mg/kg ND 0.00005 ND 0.0000486 NE 2,3,3',5,5'-PeCB 111 2,3,3',5,5'-Pentachlorobiphenyl EPA 1668A 39635-32-0 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE 2,3',4,5,5'-PeCB 120 2,3',4,5,5'-Pentachlorobiphenyl EPA 1668A 68194-12-7 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE (107/124)107/124 NA (Co-elution)EPA 1668A E52450749 mg/kg ND 0.0000971 ND 0.0001 ND 0.0000971 NE 2,3,3',4,6-PeCB 109 2,3,3',4,6-Pentachlorobiphenyl EPA 1668A 74472-35-8 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE 2,3',4,4',5'-PeCB 123 2,3',4,4',5'-Pentachlorobiphenyl EPA 1668A 65510-44-3 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE 2,3,3',4,5-PeCB 106 2,3,3',4,5-Pentachlorobiphenyl EPA 1668A 70424-69-0 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE 2,3',4,4',5-PeCB 118 2,3',4,4',5-Pentachlorobiphenyl EPA 1668A 31508-00-6 mg/kg ND 0.000064 ND 0.0000622 NE 2,3,3',4',5'-PeCB 122 2,3,3',4',5'-Pentachlorobiphenyl EPA 1668A 76842-07-4 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE 2,3,4,4',5-PeCB 114 2,3,4,4',5-Pentachlorobiphenyl EPA 1668A 74472-37-0 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE 2,3,3',4,4'-PeCB 105 2,3,3',4,4'-Pentachlorobiphenyl EPA 1668A 32598-14-4 mg/kg ND 0.00005 ND 0.0000486 NE 3,3',4,5,5'-PeCB 127 3,3',4,5,5'-Pentachlorobiphenyl EPA 1668A 39635-33-1 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE 3,3',4,4',5-PeCB 126 3,3',4,4',5-Pentachlorobiphenyl EPA 1668A 57465-28-8 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE 2,2',4,4',6,6'-HxCB 155 2,2',4,4',6,6'-Hexachlorobiphenyl EPA 1668A 33979-03-2 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE 2,2',3,5,6,6'-HxCB 152 2,2',3,5,6,6'-Hexachlorobiphenyl EPA 1668A 68194-09-2 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE 2,2',3,4',6,6'-HxCB 150 2,2',3,4',6,6'-Hexachlorobiphenyl EPA 1668A 68194-08-1 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE 2,2',3,3',6,6'-HxCB 136 2,2',3,3',6,6'-Hexachlorobiphenyl EPA 1668A 38411-22-2 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE 2,2',3,4,6,6'-HxCB 145 2,2',3,4,6,6'-Hexachlorobiphenyl EPA 1668A 74472-40-5 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE 2,2',3,4',5,6'-HxCB 148 2,2',3,4',5,6'-Hexachlorobiphenyl EPA 1668A 74472-41-6 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE (135/151)135/151 NA (Co-elution)EPA 1668A mg/kg ND 0.0000971 ND 0.0001 ND 0.0000971 NE 2,2',4,4',5,6'-HxCB 154 2,2',4,4',5,6'-Hexachlorobiphenyl EPA 1668A 60145-22-4 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE 2,2',3,4,5',6-HxCB 144 2,2',3,4,5',6-Hexachlorobiphenyl EPA 1668A 68194-14-9 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE (147/149)147/149 NA (Co-elution)EPA 1668A E52450814 mg/kg ND 0.0001 ND 0.0000971 NE (134/143)134/143 NA (Co-elution)EPA 1668A E52450780 mg/kg ND 0.0000971 ND 0.0001 ND 0.0000971 NE (139/140)139/140 NA (Co-elution)EPA 1668A E52450806 mg/kg ND 0.0000971 ND 0.0001 ND 0.0000971 NE 2,2',3,3',4,6-HxCB 131 2,2',3,3',4,6-Hexachlorobiphenyl EPA 1668A 61798-70-7 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE 2,2',3,4,5,6-HxCB 142 2,2',3,4,5,6-Hexachlorobiphenyl EPA 1668A 41411-61-4 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE 2,2',3,3',4,6'-HxCB 132 2,2',3,3',4,6'-Hexachlorobiphenyl EPA 1668A 38380-05-1 mg/kg ND 0.00005 ND 0.0000486 NE 2,2',3,3',5,5'-HxCB 133 2,2',3,3',5,5'-Hexachlorobiphenyl EPA 1668A 35694-04-3 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE 2,3,3',5,5',6-HxCB 165 2,3,3',5,5',6-Hexachlorobiphenyl EPA 1668A 74472-46-1 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE 2,2',3,4',5,5'-HxCB 146 2,2',3,4',5,5'-Hexachlorobiphenyl EPA 1668A 51908-16-8 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE 2,3,3',4,5',6-HxCB 161 2,3,3',4,5',6-Hexachlorobiphenyl EPA 1668A 74472-43-8 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE (153/168)153/168 NA (Co-elution)EPA 1668A E52450822 mg/kg ND 0.0001 ND 0.0000971 NE 0.00018 0.0000257 0.000215 0.000161 0.000249 0.0000818 0.000165 0.000226 0.000468 0.000886 0.00018 0.0000666 0.000129 0.000191 0.000106 0.000105 0.00014 0.000161 0.000232 0.000354 0.0000513 0.000335 0.000196 0.0000556 7/12/2018 7/12/2018 7/12/2018 8:35 8:40 12:30 Downstream LMC Downstream LMC Upstream LMC Surface Surface Surface Table 2-2 Little Mountain Creek Sediment Sample Analytical Results - Congener Analysis Alcoa/Badin Landfill Badin Business Park Facility Badin, North Carolina Sample ID Congener Number IUPAC Name Method CAS Units EPA Freshwater Sediment Ecological Screening Value (ESV)ABL-SD007-F005ABL-SD07-D005ABL-SD008-F005Location Depth Date Time 7/12/2018 7/12/2018 7/12/2018 8:35 8:40 12:30 Downstream LMC Downstream LMC Upstream LMC Surface Surface Surface 2,2',3,4,5,5'-HxCB 141 2,2',3,4,5,5'-Hexachlorobiphenyl EPA 1668A 52712-04-6 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE 2,2',3,3',4,5'-HxCB 130 2,2',3,3',4,5'-Hexachlorobiphenyl EPA 1668A 52663-66-8 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE 2,2',3,4,4',5-HxCB 137 2,2',3,4,4',5-Hexachlorobiphenyl EPA 1668A 35694-06-5 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE 2,3,3',4',5',6-HxCB 164 2,3,3',4',5',6-Hexachlorobiphenyl EPA 1668A 74472-45-0 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE (129/138/163)129/138/163 NA (Co-elution)EPA 1668A mg/kg ND 0.00015 ND 0.000146 NE 2,3,3',4,5,6-HxCB 160 2,3,3',4,5,6-Hexachlorobiphenyl EPA 1668A 41411-62-5 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE 2,3,3',4,4',6-HxCB 158 2,3,3',4,4',6-Hexachlorobiphenyl EPA 1668A 74472-42-7 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE (128/166)128/166 NA (Co-elution)EPA 1668A E52450764 mg/kg ND 0.0000971 ND 0.0001 ND 0.0000971 NE 2,3,3',4,5,5'-HxCB 159 2,3,3',4,5,5'-Hexachlorobiphenyl EPA 1668A 39635-35-3 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE 2,3,3',4',5,5'-HxCB 162 2,3,3',4',5,5'-Hexachlorobiphenyl EPA 1668A 39635-34-2 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE 2,3',4,4',5,5'-HxCB 167 2,3',4,4',5,5'-Hexachlorobiphenyl EPA 1668A 52663-72-6 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE (156/157)156/157 NA (Co-elution)EPA 1668A E52450830 mg/kg ND 0.0000971 ND 0.0001 ND 0.0000971 NE 3,3',4,4',5,5'-HxCB 169 3,3',4,4',5,5'-Hexachlorobiphenyl EPA 1668A 32774-16-6 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE 2,2',3,4',5,6,6'-HpCB 188 2,2',3,4',5,6,6'-Heptachlorobiphenyl EPA 1668A 74487-85-7 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE 2,2',3,3',5,6,6'-HpCB 179 2,2',3,3',5,6,6'-Heptachlorobiphenyl EPA 1668A 52663-64-6 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE 2,2',3,4,4',6,6'-HpCB 184 2,2',3,4,4',6,6'-Heptachlorobiphenyl EPA 1668A 74472-48-3 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE 2,2',3,3',4,6,6'-HpCB 176 2,2',3,3',4,6,6'-Heptachlorobiphenyl EPA 1668A 52663-65-7 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE 2,2',3,4,5,6,6'-HpCB 186 2,2',3,4,5,6,6'-Heptachlorobiphenyl EPA 1668A 74472-49-4 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE 2,2',3,3',5,5',6-HpCB 178 2,2',3,3',5,5',6-Heptachlorobiphenyl EPA 1668A 52663-67-9 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE 2,2',3,3',4,5',6-HpCB 175 2,2',3,3',4,5',6-Heptachlorobiphenyl EPA 1668A 40186-70-7 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE 2,2',3,4',5,5',6-HpCB 187 2,2',3,4',5,5',6-Heptachlorobiphenyl EPA 1668A 52663-68-0 mg/kg ND 0.00005 ND 0.0000486 NE 2,2',3,4,4',5,6'-HpCB 182 2,2',3,4,4',5,6'-Heptachlorobiphenyl EPA 1668A 60145-23-5 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE (183/185)183/185 NA (Co-elution)EPA 1668A E52450863 mg/kg ND 0.0000971 ND 0.0001 ND 0.0000971 NE 2,2',3,3',4,5,6'-HpCB 174 2,2',3,3',4,5,6'-Heptachlorobiphenyl EPA 1668A 38411-25-5 mg/kg ND 0.00005 ND 0.0000486 NE 2,2',3,3',4,5',6'-HpCB 177 2,2',3,3',4,5',6'-Heptachlorobiphenyl EPA 1668A 52663-70-4 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE 2,2',3,4,4',5,6-HpCB 181 2,2',3,4,4',5,6-Heptachlorobiphenyl EPA 1668A 74472-47-2 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE (171/173)171/173 NA (Co-elution)EPA 1668A E52450848 mg/kg ND 0.0000971 ND 0.0001 ND 0.0000971 NE 2,2',3,3',4,5,5'-HpCB 172 2,2',3,3',4,5,5'-Heptachlorobiphenyl EPA 1668A 52663-74-8 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE 2,3,3',4,5,5',6-HpCB 192 2,3,3',4,5,5',6-Heptachlorobiphenyl EPA 1668A 74472-51-8 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE (180/193)180/193 NA (Co-elution)EPA 1668A E52450855 mg/kg ND 0.0001 ND 0.0000971 NE 2,3,3',4,4',5',6-HpCB 191 2,3,3',4,4',5',6-Heptachlorobiphenyl EPA 1668A 74472-50-7 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE 2,2',3,3',4,4',5-HpCB 170 2,2',3,3',4,4',5-Heptachlorobiphenyl EPA 1668A 35065-30-6 mg/kg ND 0.00005 ND 0.0000486 NE 2,3,3',4,4',5,6-HpCB 190 2,3,3',4,4',5,6-Heptachlorobiphenyl EPA 1668A 41411-64-7 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE 2,3,3',4,4',5,5'-HpCB 189 2,3,3',4,4',5,5'-Heptachlorobiphenyl EPA 1668A 39635-31-9 mg/kg ND 0.0000485 ND 0.00005 ND 0.0000486 NE 2,2',3,3',5,5',6,6'-OcCB 202 2,2',3,3',5,5',6,6'-Octachlorobiphenyl EPA 1668A 2136-99-4 mg/kg ND 0.0000728 ND 0.000075 ND 0.0000729 NE 2,2',3,3',4,5',6,6'-OcCB 201 2,2',3,3',4,5',6,6'-Octachlorobiphenyl EPA 1668A 40186-71-8 mg/kg ND 0.0000728 ND 0.000075 ND 0.0000729 NE 2,2',3,4,4',5,6,6'-OcCB 204 2,2',3,4,4',5,6,6'-Octachlorobiphenyl EPA 1668A 74472-52-9 mg/kg ND 0.0000728 ND 0.000075 ND 0.0000729 NE (197/200)197/200 NA (Co-elution)EPA 1668A E52450871 mg/kg ND 0.000146 ND 0.00015 ND 0.000146 NE (198/199)198/199 NA (Co-elution)EPA 1668A E52450889 mg/kg ND 0.000146 ND 0.00015 ND 0.000146 NE 2,2',3,3',4,4',5,6'-OcCB 196 2,2',3,3',4,4',5,6'-Octachlorobiphenyl EPA 1668A 42740-50-1 mg/kg ND 0.0000728 ND 0.000075 ND 0.0000729 NE 2,2',3,4,4',5,5',6-OcCB 203 2,2',3,4,4',5,5',6-Octachlorobiphenyl EPA 1668A 52663-76-0 mg/kg ND 0.0000728 ND 0.000075 ND 0.0000729 NE 2,2',3,3',4,4',5,6-OcCB 195 2,2',3,3',4,4',5,6-Octachlorobiphenyl EPA 1668A 52663-78-2 mg/kg ND 0.0000728 ND 0.000075 ND 0.0000729 NE 2,2',3,3',4,4',5,5'-OcCB 194 2,2',3,3',4,4',5,5'-Octachlorobiphenyl EPA 1668A 35694-08-7 mg/kg ND 0.0000728 ND 0.000075 ND 0.0000729 NE 2,3,3',4,4',5,5',6-OcCB 205 2,3,3',4,4',5,5',6-Octachlorobiphenyl EPA 1668A 74472-53-0 mg/kg ND 0.0000728 ND 0.000075 ND 0.0000729 NE 2,2',3,3',4,5,5',6,6'-NoCB 208 2,2',3,3',4,5,5',6,6'-Nonachlorobiphenyl EPA 1668A 52663-77-1 mg/kg ND 0.0000728 ND 0.000075 ND 0.0000729 NE 2,2',3,3',4,4',5,6,6'-NoCB 207 2,2',3,3',4,4',5,6,6'-Nonachlorobiphenyl EPA 1668A 52663-79-3 mg/kg ND 0.0000728 ND 0.000075 ND 0.0000729 NE 2,2',3,3',4,4',5,5',6-NoCB 206 2,2',3,3',4,4',5,5',6-Nonachlorobiphenyl EPA 1668A 40186-72-9 mg/kg ND 0.0000728 ND 0.000075 ND 0.0000729 NE Decachlorobiphenyl 209 Decachlorobiphenyl EPA 1668A 2051-24-3 mg/kg ND 0.0000728 ND 0.000075 ND 0.0000729 NE Total Polychlorinated Biphenyls mg/kg 0.0598/0.014 ND - The analyte was not detected above laboratory detection limits. Subscript indicates compound-specific Method Specified Reporting Limit (EML) in mg/kg. ESV derived from Region 4 Ecological Risk Assessment Supplemental Guidance - March 2018 Update include both aquatic and wildlife based values. NE - Not established. 0.0000822 0.000101 0.000249 0.0056221 ND ND 0.0000649 0.000165 Table 2-3 Little Mountain Creek Surface Water Sample Analytical Results Alcoa/Badin Municipal Landfill Badin Business Park Facility Badin, North Carolina Sample ID Method CAS Units 15A NCAC 2B Surface Water StandardABL-SW008-F005ABL-SW011-F005ABL-SW012-F005ABL-SW009-F005ABL-SW010-F005ABL-SW008-D005Location Date Time pH SU 6.0-9.0 Fluoride EPA 300.0 16984-48-8 mg/l 1.8 Cyanide EPA 9012B 57-12-5 mg/l ND 0.0040 ND 0.0040 ND 0.0040 ND 0.0040 ND 0.0040 ND 0.0040 0.005 PCB-1016 (Aroclor 1016)EPA 8082 12674-11-2 mg/l ND 0.00042 ND 0.00042 ND 0.00042 ND 0.00042 ND 0.00042 ND 0.00042 NE PCB-1221 (Aroclor 1221)EPA 8082 11104-28-2 mg/l ND 0.00042 ND 0.00042 ND 0.00042 ND 0.00042 ND 0.00042 ND 0.00042 NE PCB-1232 (Aroclor 1232)EPA 8082 11141-16-5 mg/l ND 0.00042 ND 0.00042 ND 0.00042 ND 0.00042 ND 0.00042 ND 0.00042 NE PCB-1242 (Aroclor 1242)EPA 8082 53469-21-9 mg/l ND 0.00042 ND 0.00042 ND 0.00042 ND 0.00042 ND 0.00042 ND 0.00042 NE PCB-1248 (Aroclor 1248)EPA 8082 12672-29-6 mg/l ND 0.00042 ND 0.00042 ND 0.00042 ND 0.00042 ND 0.00042 ND 0.00042 NE PCB-1254 (Aroclor 1254)EPA 8082 11097-69-1 mg/l ND 0.00042 ND 0.00042 ND 0.00042 ND 0.00042 ND 0.00042 ND 0.00042 NE PCB-1260 (Aroclor 1260)EPA 8082 11096-82-5 mg/l ND 0.00042 ND 0.00042 ND 0.00042 ND 0.00042 ND 0.00042 ND 0.00042 NE Total Polychlorinated Biphenyls 1336-36-3 mg/l 0.000001 Arsenic EPA 200.7 7440-38-2 mg/l ND 0.0050 ND 0.0050 ND 0.0050 ND 0.0050 ND 0.0050 ND 0.0050 0.34 Hardness, Total (SM 2340B)EPA 200.7 mg/l 100 Lead EPA 200.7 7439-92-1 mg/l ND 0.0025 ND 0.0025 ND 0.0025 ND 0.0025 ND 0.0025 0.0209 Sample times inadvertently left off laboratory chain of custody. Sample times as recorded on bottles were documented in field book. ND - The analyte was not detected above laboratory detection limits. Subscript indicates compound-specific MDL in mg/kg. J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit. NE - Not established. The 15A NCAC 2B standard for acute lead is calculated as hardness dependent using the a hardness value of 36 mg/l. 36.6 36.0 37.3 39.2 7.42 7.55 7.31 7.04 NDNDNDND 0.078 J 0.074 J 0.078 J 0.082 J 7:30 7.47 7.39 7:10 NDND 37.8 0.0026 J 0.088 J 0.087 J 38.5 9:25 9:558:25 8:50 Downstream from NC740 LMC near Western SCA LMC Upstream of the ABL 7/12/2018 7/12/2018 7/12/2018 LMC at Eastern SCA Ditch 7/12/2018 LMC at Middle SCA Ditch 7/12/2018 Downstream from NC740 7/12/2018 Table 2-4 Little Mountain Creek Surface Water Sample Analytical Results - Congener Analysis Alcoa/Badin Landfill Badin Business Park Facility Badin, North Carolina Sample ID Congener Number IUPAC Name Method CAS Units 15A NCAC 2B Surface Water StandardABL-SW009-F005ABL-SW008-F005ABL-SW008-D005ABL-SW010-F005ABL-SW011-F005ABL-SW012-F005Location Date Time 2-MoCB 1 2-Chlorobiphenyl EPA 1668A 2051-60-7 mg/l ND 0.000000271 ND 0.000000266 ND 0.000000253 ND 0.000000259 ND 0.000000281 ND 0.000000257 NE 3-MoCB 2 3-Chlorobiphenyl EPA 1668A 2051-61-8 mg/l ND 0.000000271 ND 0.000000266 ND 0.000000253 ND 0.000000259 ND 0.000000281 ND 0.000000257 NE 4-MoCB 3 4-Chlorobiphenyl EPA 1668A 2051-62-9 mg/l ND 0.000000271 ND 0.000000266 ND 0.000000253 ND 0.000000259 ND 0.000000281 ND 0.000000257 NE 2,2'-DiCB 4 2,2'-Dichlorobiphenyl EPA 1668A 13029-08-8 mg/l ND 0.000000266 ND 0.000000253 ND 0.000000259 ND 0.000000281 ND 0.000000257 NE 2,6-DiCB 10 2,6-Dichlorobiphenyl EPA 1668A 33146-45-1 mg/l ND 0.000000271 ND 0.000000266 ND 0.000000253 ND 0.000000259 ND 0.000000281 ND 0.000000257 NE 2,5-DiCB 9 2,5-Dichlorobiphenyl EPA 1668A 34883-39-1 mg/l ND 0.000000271 ND 0.000000266 ND 0.000000253 ND 0.000000259 ND 0.000000281 ND 0.000000257 NE 2,4-DiCB 7 2,4-Dichlorobiphenyl EPA 1668A 33284-50-3 mg/l ND 0.000000271 ND 0.000000266 ND 0.000000253 ND 0.000000259 ND 0.000000281 ND 0.000000257 NE 2,3'-DiCB 6 2,3'-Dichlorobiphenyl EPA 1668A 25569-80-6 mg/l ND 0.000000271 ND 0.000000266 ND 0.000000253 ND 0.000000259 ND 0.000000281 ND 0.000000257 NE 2,3-DiCB 5 2,3-Dichlorobiphenyl EPA 1668A 16605-91-7 mg/l ND 0.000000271 ND 0.000000266 ND 0.000000253 ND 0.000000259 ND 0.000000281 ND 0.000000257 NE 2,4'-DiCB 8 2,4'-Dichlorobiphenyl EPA 1668A 34883-43-7 mg/l ND 0.000000266 ND 0.000000253 ND 0.000000259 ND 0.000000281 ND 0.000000257 NE 3,5-DiCB 14 3,5-Dichlorobiphenyl EPA 1668A 34883-41-5 mg/l ND 0.000000271 ND 0.000000266 ND 0.000000253 ND 0.000000259 ND 0.000000281 ND 0.000000257 NE 3,3'-DiCB 11 3,3'-Dichlorobiphenyl EPA 1668A 2050-67-1 mg/l ND 0.00000266 ND 0.0000026 ND 0.00000248 ND 0.00000254 ND 0.00000275 ND 0.00000252 NE (12/13)12/13 NA (Co-elution)EPA 1668A E52450566 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 4,4'-DiCB 15 4,4'-Dichlorobiphenyl EPA 1668A 2050-68-2 mg/l ND 0.000000351 ND 0.000000334 ND 0.000000342 ND 0.000000371 ND 0.00000034 NE 2,2',6-TrCB 19 2,2',6-Trichlorobiphenyl EPA 1668A 38444-73-4 mg/l ND 0.000000266 ND 0.000000253 ND 0.000000259 ND 0.000000281 ND 0.000000257 NE (18/30)18/30 NA (Co-elution)EPA 1668A E52450574 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 2,2',4-TrCB 17 2,2',4-Trichlorobiphenyl EPA 1668A 37680-66-3 mg/l ND 0.000000266 ND 0.000000253 ND 0.000000259 ND 0.000000281 ND 0.000000257 NE 2,3',6-TrCB 27 2,3',6-Trichlorobiphenyl EPA 1668A 38444-76-7 mg/l ND 0.000000271 ND 0.000000266 ND 0.000000253 ND 0.000000259 ND 0.000000281 ND 0.000000257 NE 2,3,6-TrCB 24 2,3,6-Trichlorobiphenyl EPA 1668A 55702-45-9 mg/l ND 0.000000271 ND 0.000000266 ND 0.000000253 ND 0.000000259 ND 0.000000281 ND 0.000000257 NE 2,2',3-TrCB 16 2,2',3-Trichlorobiphenyl EPA 1668A 38444-78-9 mg/l ND 0.000000271 ND 0.000000266 ND 0.000000253 ND 0.000000259 ND 0.000000281 ND 0.000000257 NE 2,4',6-TrCB 32 2,4',6-Trichlorobiphenyl EPA 1668A 38444-77-8 mg/l ND 0.000000266 ND 0.000000253 ND 0.000000259 ND 0.000000281 ND 0.000000257 NE 2,3',5'-TrCB 34 2,3',5'-Trichlorobiphenyl EPA 1668A 37680-68-5 mg/l ND 0.000000271 ND 0.000000266 ND 0.000000253 ND 0.000000259 ND 0.000000281 ND 0.000000257 NE 2,3,5-TrCB 23 2,3,5-Trichlorobiphenyl EPA 1668A 55720-44-0 mg/l ND 0.000000271 ND 0.000000266 ND 0.000000253 ND 0.000000259 ND 0.000000281 ND 0.000000257 NE (26/29)26/29 NA (Co-elution)EPA 1668A E52450608 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 2,3',4-TrCB 25 2,3',4-Trichlorobiphenyl EPA 1668A 55712-37-3 mg/l ND 0.000000271 ND 0.000000266 ND 0.000000253 ND 0.000000259 ND 0.000000281 ND 0.000000257 NE 2,4',5-TrCB 31 2,4',5-Trichlorobiphenyl EPA 1668A 16606-02-3 mg/l ND 0.00000141 ND 0.00000138 ND 0.00000132 ND 0.00000135 ND 0.00000146 ND 0.00000134 NE (20/28)20/28 NA (Co-elution)EPA 1668A E52450582 mg/l ND 0.00000137 ND 0.00000131 ND 0.00000134 ND 0.00000145 ND 0.00000133 NE (21/33)21/33 NA (Co-elution)EPA 1668A E52450590 mg/l ND 0.00000147 ND 0.00000143 ND 0.00000137 ND 0.0000014 ND 0.00000152 ND 0.00000139 NE 2,3,4'-TrCB 22 2,3,4'-Trichlorobiphenyl EPA 1668A 38444-85-8 mg/l ND 0.00000103 ND 0.00000101 ND 0.000000962 ND 0.000000983 ND 0.00000107 ND 0.000000978 NE 3,3',5-TrCB 36 3,3',5-Trichlorobiphenyl EPA 1668A 38444-87-0 mg/l ND 0.000000271 ND 0.000000266 ND 0.000000253 ND 0.000000259 ND 0.000000281 ND 0.000000257 NE 3,4',5-TrCB 39 3,4',5-Trichlorobiphenyl EPA 1668A 38444-88-1 mg/l ND 0.000000271 ND 0.000000266 ND 0.000000253 ND 0.000000259 ND 0.000000281 ND 0.000000257 NE 3,4,5-TrCB 38 3,4,5-Trichlorobiphenyl EPA 1668A 53555-66-1 mg/l ND 0.000000271 ND 0.000000266 ND 0.000000253 ND 0.000000259 ND 0.000000281 ND 0.000000257 NE 3,3',4-TrCB 35 3,3',4-Trichlorobiphenyl EPA 1668A 37680-69-6 mg/l ND 0.000000271 ND 0.000000266 ND 0.000000253 ND 0.000000259 ND 0.000000281 ND 0.000000257 NE 3,4,4'-TrCB 37 3,4,4'-Trichlorobiphenyl EPA 1668A 38444-90-5 mg/l ND 0.000000575 ND 0.000000563 ND 0.000000537 ND 0.000000549 ND 0.000000595 ND 0.000000545 NE 2,2',6,6'-TeCB 54 2,2',6,6'-Tetrachlorobiphenyl EPA 1668A 15968-05-5 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE (50/53)50/53 NA (Co-elution)EPA 1668A E52450657 mg/l ND 0.00000109 ND 0.00000106 ND 0.00000101 ND 0.00000104 ND 0.00000112 ND 0.00000103 NE (45/51)45/51 NA (Co-elution)EPA 1668A E52450632 mg/l ND 0.00000109 ND 0.00000106 ND 0.00000101 ND 0.00000104 ND 0.00000112 ND 0.00000103 NE 2,2',3,6'-TeCB 46 2,2',3,6'-Tetrachlorobiphenyl EPA 1668A 41464-47-5 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 2,2',5,5'-TeCB 52 2,2',5,5'-Tetrachlorobiphenyl EPA 1668A 35693-99-3 mg/l ND 0.00000164 ND 0.00000156 ND 0.00000159 ND 0.00000173 ND 0.00000158 NE 2,3',5',6-TeCB 73 2,3',5',6-Tetrachlorobiphenyl EPA 1668A 74338-23-1 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 43/73 43/73 NA (Co-elution)EPA 1668A mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE (49/69)49/69 NA (Co-elution)EPA 1668A E52450640 mg/l ND 0.00000106 ND 0.00000101 ND 0.00000104 ND 0.00000112 ND 0.00000103 NE 2,2',4,5-TeCB 48 2,2',4,5-Tetrachlorobiphenyl EPA 1668A 70362-47-9 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE (44/47/65)44/47/65 NA (Co-elution)EPA 1668A E52450624 mg/l ND 0.00000159 ND 0.00000152 ND 0.00000155 ND 0.00000169 ND 0.00000154 NE (59/62/75)59/62/75 NA (Co-elution)EPA 1668A E52450665 mg/l ND 0.00000163 ND 0.00000159 ND 0.00000152 ND 0.00000155 ND 0.00000169 ND 0.00000154 NE 2,2',3,4'-TeCB 42 2,2',3,4'-Tetrachlorobiphenyl EPA 1668A 36559-22-5 mg/l ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE (40/41/71)40/41/71 NA (Co-elution)EPA 1668A E52450616 mg/l ND 0.00000163 ND 0.00000159 ND 0.00000152 ND 0.00000155 ND 0.00000169 ND 0.00000154 NE 2,3,4',6-TeCB 64 2,3,4',6-Tetrachlorobiphenyl EPA 1668A 52663-58-8 mg/l ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 2,3',5,5'-TeCB 72 2,3',5,5'-Tetrachlorobiphenyl EPA 1668A 41464-42-0 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 2,3',4,5'-TeCB 68 2,3',4,5'-Tetrachlorobiphenyl EPA 1668A 73575-52-7 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 2,3,3',5-TeCB 57 2,3,3',5-Tetrachlorobiphenyl EPA 1668A 70424-67-8 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 2,3,3',5'-TeCB 58 2,3,3',5'-Tetrachlorobiphenyl EPA 1668A 41464-49-7 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 2,3',4,5-TeCB 67 2,3',4,5-Tetrachlorobiphenyl EPA 1668A 73575-53-8 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 2,3,4',5-TeCB 63 2,3,4',5-Tetrachlorobiphenyl EPA 1668A 74472-34-7 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE (61/70/74/76)60/70/74/76 NA (Co-elution)EPA 1668A E52450673 mg/l ND 0.00000213 ND 0.00000203 ND 0.00000207 ND 0.00000225 ND 0.00000206 NE 2,3',4,4'-TeCB 66 2,3',4,4'-Tetrachlorobiphenyl EPA 1668A 32598-10-0 mg/l ND 0.000000893 ND 0.000000851 ND 0.000000869 ND 0.000000944 ND 0.000000864 NE 2,3,3',4-TeCB 55 2,3,3',4-Tetrachlorobiphenyl EPA 1668A 74338-24-2 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 2,3,3',4'-TeCB 56 2,3,3',4'-Tetrachlorobiphenyl EPA 1668A 41464-43-1 mg/l ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 2,3,4,4'-TeCB 60 2,3,4,4'-Tetrachlorobiphenyl EPA 1668A 33025-41-1 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 3,3',5,5'-TeCB 80 3,3',5,5'-Tetrachlorobiphenyl EPA 1668A 33284-52-5 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 3,3',4,5'-TeCB 79 3,3',4,5'-Tetrachlorobiphenyl EPA 1668A 41464-48-6 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 3,3',4,5-TeCB 78 3,3',4,5-Tetrachlorobiphenyl EPA 1668A 70362-49-1 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 3,4,4',5-TeCB 81 3,4,4',5-Tetrachlorobiphenyl EPA 1668A 70362-50-4 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 3,3',4,4'-TeCB 77 3,3',4,4'-Tetrachlorobiphenyl EPA 1668A 32598-13-3 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 2,2',4,6,6'-PeCB 104 2,2',4,6,6'-Pentachlorobiphenyl EPA 1668A 56558-16-8 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 2,2',3,6,6'-PeCB 96 2,2',3,6,6'-Pentachlorobiphenyl EPA 1668A 73575-54-9 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 2,2',4,5',6-PeCB 103 2,2',4,5',6-Pentachlorobiphenyl EPA 1668A 60145-21-3 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 2,2',3,5,6'-PeCB 94 2,2',3,5,6'-Pentachlorobiphenyl EPA 1668A 73575-55-0 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 2,2',3,5',6-PeCB 95 2,2',3,5',6-Pentachlorobiphenyl EPA 1668A 38379-99-6 mg/l ND 0.00000101 ND 0.000000962 ND 0.000000983 ND 0.00000107 ND 0.000000978 NE (93/98/100/102)93/98/100/102 NA (Co-elution)EPA 1668A mg/l ND 0.00000217 ND 0.00000213 ND 0.00000203 ND 0.00000207 ND 0.00000225 ND 0.00000206 NE (88/91)88/91 NA (Co-elution)EPA 1668A E52450715 mg/l ND 0.00000109 ND 0.00000106 ND 0.00000101 ND 0.00000104 ND 0.00000112 ND 0.00000103 NE 2,2',3,3',6-PeCB 84 2,2',3,3',6-Pentachlorobiphenyl EPA 1668A 52663-60-2 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 2,2',3,4,6'-PeCB 89 2,2',3,4,6'-Pentachlorobiphenyl EPA 1668A 73575-57-2 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 2,3',4,5',6-PeCB 121 2,3',4,5',6-Pentachlorobiphenyl EPA 1668A 56558-18-0 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 2,2',3,5,5'-PeCB 92 2,2',3,5,5'-Pentachlorobiphenyl EPA 1668A 52663-61-3 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE (90/101/113)90/101/113 NA (Co-elution)EPA 1668A E52450723 mg/l ND 0.00000159 ND 0.00000152 ND 0.00000155 ND 0.00000169 ND 0.00000154 NE 2,2',3,3',5-PeCB 83 2,2',3,3',5-Pentachlorobiphenyl EPA 1668A 60145-20-2 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 2,2',4,4',5-PeCB 99 2,2',4,4',5-Pentachlorobiphenyl EPA 1668A 38380-01-7 mg/l ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 2,3,3',5,6-PeCB 112 2,3,3',5,6-Pentachlorobiphenyl EPA 1668A 74472-36-9 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE (86/87/97/108/119/125)86/87/97/108/119'125 NA (Co-elution)EPA 1668A E52450707 mg/l ND 0.00000326 ND 0.00000319 ND 0.00000304 ND 0.00000311 ND 0.00000337 ND 0.00000309 NE (85/117/116)85/117/116 NA (Co-elution)EPA 1668A E52450699 mg/l ND 0.00000163 ND 0.00000159 ND 0.00000152 ND 0.00000155 ND 0.00000169 ND 0.00000154 NE (110/115)110/115 NA (Co-elution)EPA 1668A E52450756 mg/l ND 0.00000106 ND 0.00000101 ND 0.00000104 ND 0.00000112 ND 0.00000103 NE 2,2',3,3',4-PeCB 82 2,2',3,3',4-Pentachlorobiphenyl EPA 1668A 52663-62-4 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 2,3,3',5,5'-PeCB 111 2,3,3',5,5'-Pentachlorobiphenyl EPA 1668A 39635-32-0 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 2,3',4,5,5'-PeCB 120 2,3',4,5,5'-Pentachlorobiphenyl EPA 1668A 68194-12-7 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE (107/124)107/124 NA (Co-elution)EPA 1668A E52450749 mg/l ND 0.00000109 ND 0.00000106 ND 0.00000101 ND 0.00000104 ND 0.00000112 ND 0.00000103 NE 2,3,3',4,6-PeCB 109 2,3,3',4,6-Pentachlorobiphenyl EPA 1668A 74472-35-8 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 2,3',4,4',5'-PeCB 123 2,3',4,4',5'-Pentachlorobiphenyl EPA 1668A 65510-44-3 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 2,3,3',4,5-PeCB 106 2,3,3',4,5-Pentachlorobiphenyl EPA 1668A 70424-69-0 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 2,3',4,4',5-PeCB 118 2,3',4,4',5-Pentachlorobiphenyl EPA 1668A 31508-00-6 mg/l ND 0.00000068 ND 0.000000648 ND 0.000000662 ND 0.000000719 ND 0.000000659 NE 2,3,3',4',5'-PeCB 122 2,3,3',4',5'-Pentachlorobiphenyl EPA 1668A 76842-07-4 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 2,3,4,4',5-PeCB 114 2,3,4,4',5-Pentachlorobiphenyl EPA 1668A 74472-37-0 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 2,3,3',4,4'-PeCB 105 2,3,3',4,4'-Pentachlorobiphenyl EPA 1668A 32598-14-4 mg/l ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 3,3',4,5,5'-PeCB 127 3,3',4,5,5'-Pentachlorobiphenyl EPA 1668A 39635-33-1 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 3,3',4,4',5-PeCB 126 3,3',4,4',5-Pentachlorobiphenyl EPA 1668A 57465-28-8 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 2,2',4,4',6,6'-HxCB 155 2,2',4,4',6,6'-Hexachlorobiphenyl EPA 1668A 33979-03-2 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 2,2',3,5,6,6'-HxCB 152 2,2',3,5,6,6'-Hexachlorobiphenyl EPA 1668A 68194-09-2 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 2,2',3,4',6,6'-HxCB 150 2,2',3,4',6,6'-Hexachlorobiphenyl EPA 1668A 68194-08-1 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 2,2',3,3',6,6'-HxCB 136 2,2',3,3',6,6'-Hexachlorobiphenyl EPA 1668A 38411-22-2 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 2,2',3,4,6,6'-HxCB 145 2,2',3,4,6,6'-Hexachlorobiphenyl EPA 1668A 74472-40-5 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 2,2',3,4',5,6'-HxCB 148 2,2',3,4',5,6'-Hexachlorobiphenyl EPA 1668A 74472-41-6 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE (135/151)135/151 NA (Co-elution)EPA 1668A mg/l ND 0.00000109 ND 0.00000106 ND 0.00000101 ND 0.00000104 ND 0.00000112 ND 0.00000103 NE 2,2',4,4',5,6'-HxCB 154 2,2',4,4',5,6'-Hexachlorobiphenyl EPA 1668A 60145-22-4 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 2,2',3,4,5',6-HxCB 144 2,2',3,4,5',6-Hexachlorobiphenyl EPA 1668A 68194-14-9 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE (147/149)147/149 NA (Co-elution)EPA 1668A E52450814 mg/l ND 0.00000109 ND 0.00000106 ND 0.00000101 ND 0.00000104 ND 0.00000112 ND 0.00000103 NE (134/143)134/143 NA (Co-elution)EPA 1668A E52450780 mg/l ND 0.00000109 ND 0.00000106 ND 0.00000101 ND 0.00000104 ND 0.00000112 ND 0.00000103 NE (139/140)139/140 NA (Co-elution)EPA 1668A E52450806 mg/l ND 0.00000109 ND 0.00000106 ND 0.00000101 ND 0.00000104 ND 0.00000112 ND 0.00000103 NE 2,2',3,3',4,6-HxCB 131 2,2',3,3',4,6-Hexachlorobiphenyl EPA 1668A 61798-70-7 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 2,2',3,4,5,6-HxCB 142 2,2',3,4,5,6-Hexachlorobiphenyl EPA 1668A 41411-61-4 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 2,2',3,3',4,6'-HxCB 132 2,2',3,3',4,6'-Hexachlorobiphenyl EPA 1668A 38380-05-1 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 2,2',3,3',5,5'-HxCB 133 2,2',3,3',5,5'-Hexachlorobiphenyl EPA 1668A 35694-04-3 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 2,3,3',5,5',6-HxCB 165 2,3,3',5,5',6-Hexachlorobiphenyl EPA 1668A 74472-46-1 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 2,2',3,4',5,5'-HxCB 146 2,2',3,4',5,5'-Hexachlorobiphenyl EPA 1668A 51908-16-8 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 2,3,3',4,5',6-HxCB 161 2,3,3',4,5',6-Hexachlorobiphenyl EPA 1668A 74472-43-8 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE (153/168)153/168 NA (Co-elution)EPA 1668A E52450822 mg/l ND 0.00000109 ND 0.00000106 ND 0.00000101 ND 0.00000104 ND 0.00000112 ND 0.00000103 NE 2,2',3,4,5,5'-HxCB 141 2,2',3,4,5,5'-Hexachlorobiphenyl EPA 1668A 52712-04-6 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 2,2',3,3',4,5'-HxCB 130 2,2',3,3',4,5'-Hexachlorobiphenyl EPA 1668A 52663-66-8 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 2,2',3,4,4',5-HxCB 137 2,2',3,4,4',5-Hexachlorobiphenyl EPA 1668A 35694-06-5 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 2,3,3',4',5',6-HxCB 164 2,3,3',4',5',6-Hexachlorobiphenyl EPA 1668A 74472-45-0 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE (129/138/163)129/138/163 NA (Co-elution)EPA 1668A mg/l ND 0.00000163 ND 0.00000159 ND 0.00000152 ND 0.00000155 ND 0.00000169 ND 0.00000154 NE 2,3,3',4,5,6-HxCB 160 2,3,3',4,5,6-Hexachlorobiphenyl EPA 1668A 41411-62-5 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 2,3,3',4,4',6-HxCB 158 2,3,3',4,4',6-Hexachlorobiphenyl EPA 1668A 74472-42-7 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE (128/166)128/166 NA (Co-elution)EPA 1668A E52450764 mg/l ND 0.00000109 ND 0.00000106 ND 0.00000101 ND 0.00000104 ND 0.00000112 ND 0.00000103 NE 2,3,3',4,5,5'-HxCB 159 2,3,3',4,5,5'-Hexachlorobiphenyl EPA 1668A 39635-35-3 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 2,3,3',4',5,5'-HxCB 162 2,3,3',4',5,5'-Hexachlorobiphenyl EPA 1668A 39635-34-2 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 2,3',4,4',5,5'-HxCB 167 2,3',4,4',5,5'-Hexachlorobiphenyl EPA 1668A 52663-72-6 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE (156/157)156/157 NA (Co-elution)EPA 1668A E52450830 mg/l ND 0.00000109 ND 0.00000106 ND 0.00000101 ND 0.00000104 ND 0.00000112 ND 0.00000103 NE 3,3',4,4',5,5'-HxCB 169 3,3',4,4',5,5'-Hexachlorobiphenyl EPA 1668A 32774-16-6 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 2,2',3,4',5,6,6'-HpCB 188 2,2',3,4',5,6,6'-Heptachlorobiphenyl EPA 1668A 74487-85-7 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 2,2',3,3',5,6,6'-HpCB 179 2,2',3,3',5,6,6'-Heptachlorobiphenyl EPA 1668A 52663-64-6 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 2,2',3,4,4',6,6'-HpCB 184 2,2',3,4,4',6,6'-Heptachlorobiphenyl EPA 1668A 74472-48-3 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 2,2',3,3',4,6,6'-HpCB 176 2,2',3,3',4,6,6'-Heptachlorobiphenyl EPA 1668A 52663-65-7 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 2,2',3,4,5,6,6'-HpCB 186 2,2',3,4,5,6,6'-Heptachlorobiphenyl EPA 1668A 74472-49-4 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 2,2',3,3',5,5',6-HpCB 178 2,2',3,3',5,5',6-Heptachlorobiphenyl EPA 1668A 52663-67-9 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 2,2',3,3',4,5',6-HpCB 175 2,2',3,3',4,5',6-Heptachlorobiphenyl EPA 1668A 40186-70-7 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 0.00000174 0.000000897 0.00000319 0.00000127 0.00000125 0.00000174 0.00000139 0.00000234 0.00000379 0.000000331 0.000000959 0.000000289 0.000000694 0.000000519 0.00000143 0.00000221 0.00000177 0.00000292 0.000000615 0.00000106 7:30 LMC at Eastern SCA Ditch 7/12/2018 8:25 0.000000357 8:50 9:25 9:55 Downstream from NC740 7/12/2018 7:10 Downstream from NC740 7/12/2018 LMC at Middle SCA Ditch LMC near Western SCA LMC Upstream of the ABL 7/12/2018 7/12/2018 7/12/2018 Table 2-4 Little Mountain Creek Surface Water Sample Analytical Results - Congener Analysis Alcoa/Badin Landfill Badin Business Park Facility Badin, North Carolina Sample ID Congener Number IUPAC Name Method CAS Units 15A NCAC 2B Surface Water StandardABL-SW009-F005ABL-SW008-F005ABL-SW008-D005ABL-SW010-F005ABL-SW011-F005ABL-SW012-F005Location Date Time 7:30 LMC at Eastern SCA Ditch 7/12/2018 8:25 8:50 9:25 9:55 Downstream from NC740 7/12/2018 7:10 Downstream from NC740 7/12/2018 LMC at Middle SCA Ditch LMC near Western SCA LMC Upstream of the ABL 7/12/2018 7/12/2018 7/12/2018 2,2',3,4',5,5',6-HpCB 187 2,2',3,4',5,5',6-Heptachlorobiphenyl EPA 1668A 52663-68-0 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 2,2',3,4,4',5,6'-HpCB 182 2,2',3,4,4',5,6'-Heptachlorobiphenyl EPA 1668A 60145-23-5 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE (183/185)183/185 NA (Co-elution)EPA 1668A E52450863 mg/l ND 0.00000109 ND 0.00000106 ND 0.00000101 ND 0.00000104 ND 0.00000112 ND 0.00000103 NE 2,2',3,3',4,5,6'-HpCB 174 2,2',3,3',4,5,6'-Heptachlorobiphenyl EPA 1668A 38411-25-5 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 2,2',3,3',4,5',6'-HpCB 177 2,2',3,3',4,5',6'-Heptachlorobiphenyl EPA 1668A 52663-70-4 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 2,2',3,4,4',5,6-HpCB 181 2,2',3,4,4',5,6-Heptachlorobiphenyl EPA 1668A 74472-47-2 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE (171/173)171/173 NA (Co-elution)EPA 1668A E52450848 mg/l ND 0.00000109 ND 0.00000106 ND 0.00000101 ND 0.00000104 ND 0.00000112 ND 0.00000103 NE 2,2',3,3',4,5,5'-HpCB 172 2,2',3,3',4,5,5'-Heptachlorobiphenyl EPA 1668A 52663-74-8 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 2,3,3',4,5,5',6-HpCB 192 2,3,3',4,5,5',6-Heptachlorobiphenyl EPA 1668A 74472-51-8 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE (180/193)180/193 NA (Co-elution)EPA 1668A E52450855 mg/l ND 0.00000109 ND 0.00000106 ND 0.00000101 ND 0.00000104 ND 0.00000112 ND 0.00000103 NE 2,3,3',4,4',5',6-HpCB 191 2,3,3',4,4',5',6-Heptachlorobiphenyl EPA 1668A 74472-50-7 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 2,2',3,3',4,4',5-HpCB 170 2,2',3,3',4,4',5-Heptachlorobiphenyl EPA 1668A 35065-30-6 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 2,3,3',4,4',5,6-HpCB 190 2,3,3',4,4',5,6-Heptachlorobiphenyl EPA 1668A 41411-64-7 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 2,3,3',4,4',5,5'-HpCB 189 2,3,3',4,4',5,5'-Heptachlorobiphenyl EPA 1668A 39635-31-9 mg/l ND 0.000000543 ND 0.000000531 ND 0.000000506 ND 0.000000518 ND 0.000000562 ND 0.000000515 NE 2,2',3,3',5,5',6,6'-OcCB 202 2,2',3,3',5,5',6,6'-Octachlorobiphenyl EPA 1668A 2136-99-4 mg/l ND 0.000000814 ND 0.000000797 ND 0.00000076 ND 0.000000776 ND 0.000000843 ND 0.000000772 NE 2,2',3,3',4,5',6,6'-OcCB 201 2,2',3,3',4,5',6,6'-Octachlorobiphenyl EPA 1668A 40186-71-8 mg/l ND 0.000000814 ND 0.000000797 ND 0.00000076 ND 0.000000776 ND 0.000000843 ND 0.000000772 NE 2,2',3,4,4',5,6,6'-OcCB 204 2,2',3,4,4',5,6,6'-Octachlorobiphenyl EPA 1668A 74472-52-9 mg/l ND 0.000000814 ND 0.000000797 ND 0.00000076 ND 0.000000776 ND 0.000000843 ND 0.000000772 NE (197/200)197/200 NA (Co-elution)EPA 1668A E52450871 mg/l ND 0.00000163 ND 0.00000159 ND 0.00000152 ND 0.00000155 ND 0.00000169 ND 0.00000154 NE (198/199)198/199 NA (Co-elution)EPA 1668A E52450889 mg/l ND 0.00000163 ND 0.00000159 ND 0.00000152 ND 0.00000155 ND 0.00000169 ND 0.00000154 NE 2,2',3,3',4,4',5,6'-OcCB 196 2,2',3,3',4,4',5,6'-Octachlorobiphenyl EPA 1668A 42740-50-1 mg/l ND 0.000000814 ND 0.000000797 ND 0.00000076 ND 0.000000776 ND 0.000000843 ND 0.000000772 NE 2,2',3,4,4',5,5',6-OcCB 203 2,2',3,4,4',5,5',6-Octachlorobiphenyl EPA 1668A 52663-76-0 mg/l ND 0.000000814 ND 0.000000797 ND 0.00000076 ND 0.000000776 ND 0.000000843 ND 0.000000772 NE 2,2',3,3',4,4',5,6-OcCB 195 2,2',3,3',4,4',5,6-Octachlorobiphenyl EPA 1668A 52663-78-2 mg/l ND 0.000000814 ND 0.000000797 ND 0.00000076 ND 0.000000776 ND 0.000000843 ND 0.000000772 NE 2,2',3,3',4,4',5,5'-OcCB 194 2,2',3,3',4,4',5,5'-Octachlorobiphenyl EPA 1668A 35694-08-7 mg/l ND 0.000000814 ND 0.000000797 ND 0.00000076 ND 0.000000776 ND 0.000000843 ND 0.000000772 NE 2,3,3',4,4',5,5',6-OcCB 205 2,3,3',4,4',5,5',6-Octachlorobiphenyl EPA 1668A 74472-53-0 mg/l ND 0.000000814 ND 0.000000797 ND 0.00000076 ND 0.000000776 ND 0.000000843 ND 0.000000772 NE 2,2',3,3',4,5,5',6,6'-NoCB 208 2,2',3,3',4,5,5',6,6'-Nonachlorobiphenyl EPA 1668A 52663-77-1 mg/l ND 0.000000814 ND 0.000000797 ND 0.00000076 ND 0.000000776 ND 0.000000843 ND 0.000000772 NE 2,2',3,3',4,4',5,6,6'-NoCB 207 2,2',3,3',4,4',5,6,6'-Nonachlorobiphenyl EPA 1668A 52663-79-3 mg/l ND 0.000000814 ND 0.000000797 ND 0.00000076 ND 0.000000776 ND 0.000000843 ND 0.000000772 NE 2,2',3,3',4,4',5,5',6-NoCB 206 2,2',3,3',4,4',5,5',6-Nonachlorobiphenyl EPA 1668A 40186-72-9 mg/l ND 0.000000814 ND 0.000000797 ND 0.00000076 ND 0.000000776 ND 0.000000843 ND 0.000000772 NE Decachlorobiphenyl 209 Decachlorobiphenyl EPA 1668A 2051-24-3 mg/l ND 0.000000814 ND 0.000000797 ND 0.00000076 ND 0.000000776 ND 0.000000843 ND 0.000000772 NE Total Polychlorinated Biphenyls 1336-36-3 mg/l 0.000001 Sample times inadvertently left off laboratory chain of custody. Sample times as recorded on bottles were documented in field book. ND - The analyte was not detected above laboratory detection limits. Subscript indicates compound-specific Method Specified Reporting Limit (EML) in mg/kg. I - Interference present. Concentration indicated represents the Estimated Maximum Possible Concentration. ND0.000030761 ND ND ND ND Table 2-5 Little Mountain Creek Surface Water Sample Analytical Results Alcoa/Badin Municipal Landfill Badin Business Park Facility Badin, North Carolina Sample ID Method CAS 40 CFR 423 Appendix A Number Units 15A NCAC 2B Surface Water StandardABL-SW008-F005ABL-SW008-D005ABL-SW012-F005Location Date Time pH SU 6.0-9.0 Hardness, Total (SM 2340B)EPA 200.7 mg/l 100 Antimony EPA 200.7 7440-36-0 114 mg/l ND 0.0039 ND 0.0039 ND 0.0039 NE Arsenic EPA 200.7 7440-38-2 115 mg/l ND 0.0050 ND 0.0050 ND 0.0050 0.01 Beryllium EPA 200.7 7440-41-7 117 mg/l ND 0.000050 ND 0.000050 ND 0.000050 0.065 Cadmium EPA 200.7 7440-43-9 118 mg/l ND 0.00050 ND 0.00050 ND 0.00050 0.0011 Chromium EPA 200.7 7440-47-3 119 mg/l ND 0.0025 ND 0.0025 ND 0.0025 0.25 Copper EPA 200.7 7440-50-8 120 mg/l ND 0.0025 ND 0.0025 ND 0.0025 0.0051 Lead EPA 200.7 7439-92-1 122 mg/l ND 0.0025 ND 0.0025 ND 0.0025 0.021 Nickel EPA 200.7 7440-02-0 124 mg/l ND 0.0025 ND 0.0025 ND 0.0025 0.025 Selenium EPA 200.7 7782-49-2 125 mg/l ND 0.0050 ND 0.0050 ND 0.0050 0.005 Silver EPA 200.7 7440-22-4 126 mg/l ND 0.0025 ND 0.0025 ND 0.0025 0.00055 Thallium EPA 200.7 7440-28-0 127 mg/l ND 0.0050 ND 0.0050 ND 0.0050 NE Zinc EPA 200.7 7440-66-6 128 mg/l ND 0.0025 ND 0.0025 ND 0.0025 0.049 Mercury EPA 245.1 7439-97-6 123 mg/l ND 0.000070 ND 0.000070 ND 0.000070 0.000012 0 Phenol EPA 420.4 108-95-2 65 mg/l 0.0090 J 0.0050 0.0066 J 0.0050 0.0064 J 0.0050 0.3 Cyanide SM 4500-CN-E-2011 57-12-5 121 mg/l ND 0.0040 ND 0.0040 ND 0.0040 0.005 4,4'-DDD EPA 608.3 72-54-8 94 mg/l ND 0.000050 ND 0.000050 ND 0.000050 NE 4,4'-DDE EPA 608.3 72-55-9 93 mg/l ND 0.000050 ND 0.000050 ND 0.000050 NE 4,4'-DDT EPA 608.3 50-29-3 92 mg/l ND 0.000050 ND 0.000050 ND 0.000050 0.0000002 Aldrin EPA 608.3 309-00-2 89 mg/l ND 0.000050 ND 0.000050 ND 0.000050 0.00000005 alpha-BHC EPA 608.3 319-84-6 102 mg/l ND 0.000050 ND 0.000050 ND 0.000050 NE beta-BHC EPA 608.3 319-85-7 103 mg/l ND 0.000050 ND 0.000050 ND 0.000050 NE Chlordane (Technical)EPA 608.3 57-74-9 91 mg/l ND 0.00050 ND 0.00050 ND 0.00050 0.0000008 delta-BHC EPA 608.3 319-86-8 105 mg/l ND 0.000050 ND 0.000050 ND 0.000050 NE Dieldrin EPA 608.3 60-57-1 90 mg/l ND 0.000050 ND 0.000050 ND 0.000050 0.00000005 Endosulfan I EPA 608.3 959-98-8 95 mg/l ND 0.000050 ND 0.000050 ND 0.000050 0.00005 Endosulfan II EPA 608.3 33213-65-9 96 mg/l ND 0.000050 ND 0.000050 ND 0.000050 0.00005 Endosulfan sulfate EPA 608.3 1031-07-8 97 mg/l ND 0.000050 ND 0.000050 ND 0.000050 NE Endrin EPA 608.3 72-20-8 98 mg/l ND 0.000050 ND 0.000050 ND 0.000050 0.000002 Endrin aldehyde EPA 608.3 7421-93-4 99 mg/l ND 0.000050 ND 0.000050 ND 0.000050 NE gamma-BHC (Lindane)EPA 608.3 58-89-9 104 mg/l ND 0.000050 ND 0.000050 ND 0.000050 0.00001 Heptachlor EPA 608.3 76-44-8 100 mg/l ND 0.000050 ND 0.000050 ND 0.000050 0.00000008 Heptachlor epoxide EPA 608.3 1024-57-3 101 mg/l ND 0.000050 ND 0.000050 ND 0.000050 NE PCB-1016 (Aroclor 1016)EPA 608.3 12674-11-2 112 mg/l ND 0.00050 ND 0.00050 ND 0.00050 NE PCB-1221 (Aroclor 1221)EPA 608.3 11104-28-2 108 mg/l ND 0.00050 ND 0.00050 ND 0.00050 NE PCB-1232 (Aroclor 1232)EPA 608.3 11141-16-5 109 mg/l ND 0.00050 ND 0.00050 ND 0.00050 NE PCB-1242 (Aroclor 1242)EPA 608.3 53469-21-9 106 mg/l ND 0.00050 ND 0.00050 ND 0.00050 NE PCB-1248 (Aroclor 1248)EPA 608.3 12672-29-6 110 mg/l ND 0.00050 ND 0.00050 ND 0.00050 NE PCB-1254 (Aroclor 1254)EPA 608.3 11097-69-1 107 mg/l ND 0.00050 ND 0.00050 ND 0.00050 NE PCB-1260 (Aroclor 1260)EPA 608.3 11096-82-5 111 mg/l ND 0.00050 ND 0.00050 ND 0.00050 NE Total PCBs EPA 608.3 ----mg/l 0.000001 Toxaphene EPA 608.3 8001-35-2 113 mg/l ND 0.00050 ND 0.00050 ND 0.00050 0.0000002 1,1,1-Trichloroethane EPA 624 71-55-6 11 mg/l ND 0.0019 ND 0.0019 ND 0.0019 NE 1,1,2,2-Tetrachloroethane EPA 624 79-34-5 15 mg/l ND 0.0015 ND 0.0015 ND 0.0015 0.00017 1,1,2-Trichloroethane EPA 624 79-00-5 14 mg/l ND 0.0017 ND 0.0017 ND 0.0017 NE 1,1-Dichloroethane EPA 624 75-34-3 13 mg/l ND 0.0018 ND 0.0018 ND 0.0018 NE 1,1-Dichloroethene EPA 624 75-35-4 29 mg/l ND 0.0019 ND 0.0019 ND 0.0019 NE 1,2,4-Trichlorobenzene EPA 624 120-82-1 8 mg/l ND 0.0017 ND 0.0017 ND 0.0017 NE 1,2-Dichlorobenzene EPA 624 95-50-1 25 mg/l ND 0.0015 ND 0.0015 ND 0.0015 NE 1,2-Dichloroethane EPA 624 107-06-2 10 mg/l ND 0.0018 ND 0.0018 ND 0.0018 NE 1,2-Dichloropropane EPA 624 78-87-5 32 mg/l ND 0.0017 ND 0.0017 ND 0.0017 NE 1,3-Dichlorobenzene EPA 624 541-73-1 26 mg/l ND 0.0015 ND 0.0015 ND 0.0015 NE 1,4-Dichlorobenzene EPA 624 106-46-7 27 mg/l ND 0.0015 ND 0.0015 ND 0.0015 NE 2-Chloroethylvinyl ether EPA 624 110-75-8 19 mg/l ND 0.0022 ND 0.0022 ND 0.0022 NE Acrolein EPA 624 107-02-8 2 mg/l ND 0.0010 ND 0.0010 ND 0.0010 NE Acrylonitrile EPA 624 107-13-1 3 mg/l ND 0.0115 ND 0.0115 ND 0.0115 NE Benzene EPA 624 71-43-2 4 mg/l ND 0.0017 ND 0.0017 ND 0.0017 0.00119 Bromodichloromethane EPA 624 75-27-4 48 mg/l ND 0.0017 ND 0.0017 ND 0.0017 NE Bromoform EPA 624 75-25-2 47 mg/l ND 0.0015 ND 0.0015 ND 0.0015 NE Bromomethane EPA 624 74-83-9 46 mg/l ND 0.0010 ND 0.0010 ND 0.0010 NE Carbon tetrachloride EPA 624 56-23-5 6 mg/l ND 0.0019 ND 0.0019 ND 0.0019 0.000254 Chlorobenzene EPA 624 108-90-7 7 mg/l ND 0.0017 ND 0.0017 ND 0.0017 NE Chloroethane EPA 624 75-00-3 16 mg/l ND 0.0016 ND 0.0016 ND 0.0016 NE Chloroform EPA 624 67-66-3 23 mg/l ND 0.0019 ND 0.0019 ND 0.0019 NE Chloromethane EPA 624 74-87-3 45 mg/l ND 0.0015 ND 0.0015 ND 0.0015 NE cis-1,3-Dichloropropene EPA 624 10061-01-5 33 mg/l ND 0.0016 ND 0.0016 ND 0.0016 NE Dibromochloromethane EPA 624 124-48-1 51 mg/l ND 0.0018 ND 0.0018 ND 0.0018 NE Ethylbenzene EPA 624 100-41-4 38 mg/l ND 0.0016 ND 0.0016 ND 0.0016 NE Methylene Chloride EPA 624 75-09-2 44 mg/l ND 0.0019 ND 0.0019 ND 0.0019 NE Tetrachloroethene EPA 624 127-18-4 85 mg/l ND 0.0018 ND 0.0018 ND 0.0018 0.0007 Toluene EPA 624 108-88-3 86 mg/l ND 0.0016 ND 0.0016 ND 0.0016 0.011 trans-1,2-Dichloroethene EPA 624 156-60-5 30 mg/l ND 0.0018 ND 0.0018 ND 0.0018 NE trans-1,3-Dichloropropene EPA 624 10061-02-6 33 mg/l ND 0.0016 ND 0.0016 ND 0.0016 NE Trichloroethene EPA 624 79-01-6 87 mg/l ND 0.0018 ND 0.0018 ND 0.0018 0.0025 Trichlorofluoromethane EPA 624 75-69-4 #N/A mg/l ND 0.0017 ND 0.0017 ND 0.0017 NE Vinyl chloride EPA 624 75-01-4 88 mg/l ND 0.0015 ND 0.0015 ND 0.0015 0.000025 Total Chlorinated Benzenes 1 mg/l 0.488NDNDND NDNDND 7:10 7:30 9:55 7/12/2018 7/12/2018 7/12/2018 LMC Upstream of the ABL 37.8 38.5 39.2 Downstream from NC740 Downstream from NC740 7.47 7.39 7.04 Table 2-5 Little Mountain Creek Surface Water Sample Analytical Results Alcoa/Badin Municipal Landfill Badin Business Park Facility Badin, North Carolina Sample ID Method CAS 40 CFR 423 Appendix A Number Units 15A NCAC 2B Surface Water StandardABL-SW008-F005ABL-SW008-D005ABL-SW012-F005Location Date Time 7:10 7:30 9:55 7/12/2018 7/12/2018 7/12/2018 LMC Upstream of the ABLDownstream from NC740 Downstream from NC740 1,2-Diphenylhydrazine EPA 625.1 122-66-7 37 mg/l ND 0.00090 ND 0.00090 ND 0.00087 NE 2,4,6-Trichlorophenol EPA 625.1 88-06-2 21 mg/l ND 0.0013 ND 0.0013 ND 0.0012 NE 2,4-Dichlorophenol EPA 625.1 120-83-2 31 mg/l ND 0.0017 ND 0.0017 ND 0.0016 NE 2,4-Dimethylphenol EPA 625.1 105-67-9 34 mg/l ND 0.0012 ND 0.0012 ND 0.0012 NE 2,4-Dinitrophenol EPA 625.1 51-28-5 59 mg/l ND 0.0090 ND 0.0090 ND 0.0087 NE 2,4-Dinitrotoluene EPA 625.1 121-14-2 35 mg/l ND 0.00090 ND 0.00090 ND 0.00087 NE 2,6-Dinitrotoluene EPA 625.1 606-20-2 36 mg/l ND 0.00098 ND 0.00098 ND 0.00094 NE 2-Chloronaphthalene EPA 625.1 91-58-7 20 mg/l ND 0.00098 ND 0.00098 ND 0.00094 NE 2-Chlorophenol EPA 625.1 95-57-8 24 mg/l ND 0.0013 ND 0.0013 ND 0.0012 NE 2-Methylnaphthalene EPA 625.1 91-57-6 #N/A mg/l ND 0.00028 ND 0.00028 ND 0.00027 NE 2-Nitrophenol EPA 625.1 88-75-5 57 mg/l ND 0.00091 ND 0.00091 ND 0.00088 NE 3&4-Methylphenol(m&p Cresol)EPA 625.1 15831-10-4 #N/A mg/l ND 0.0020 ND 0.0020 ND 0.0019 NE 3,3'-Dichlorobenzidine EPA 625.1 91-94-1 28 mg/l ND 0.0021 ND 0.0021 ND 0.0020 NE 4,6-Dinitro-2-methylphenol EPA 625.1 534-52-1 60 mg/l ND 0.0026 ND 0.0026 ND 0.0025 NE 4-Bromophenylphenyl ether EPA 625.1 101-55-3 41 mg/l ND 0.00082 ND 0.00082 ND 0.00079 NE 4-Chloro-3-methylphenol EPA 625.1 59-50-7 22 mg/l ND 0.0037 ND 0.0037 ND 0.0036 NE 4-Chlorophenylphenyl ether EPA 625.1 7005-72-3 40 mg/l ND 0.00087 ND 0.00087 ND 0.00084 NE 4-Nitrophenol EPA 625.1 100-02-7 58 mg/l ND 0.0041 ND 0.0039 NE Acenaphthene EPA 625.1 83-32-9 1 mg/l ND 0.00025 ND 0.00025 ND 0.00024 NE Acenaphthylene EPA 625.1 208-96-8 77 mg/l ND 0.00021 ND 0.00021 ND 0.00020 NE Anthracene EPA 625.1 120-12-7 78 mg/l ND 0.00014 ND 0.00014 ND 0.00013 NE Benzidine EPA 625.1 92-87-5 5 mg/l ND 0.0051 ND 0.0051 ND 0.0049 NE Benzo(a)anthracene EPA 625.1 56-55-3 72 mg/l ND 0.00032 NE Benzo(a)pyrene EPA 625.1 50-32-8 73 mg/l ND 0.00029 NE Benzo(b)fluoranthene EPA 625.1 205-99-2 74 mg/l ND 0.00027 NE Benzo(g,h,i)perylene EPA 625.1 191-24-2 79 mg/l ND 0.00038 ND 0.00038 ND 0.00037 NE Benzo(k)fluoranthene EPA 625.1 207-08-9 75 mg/l ND 0.00041 NE bis(2-Chloroethoxy)methane EPA 625.1 111-91-1 43 mg/l ND 0.00092 ND 0.00092 ND 0.00088 NE bis(2-Chloroethyl) ether EPA 625.1 111-44-4 18 mg/l ND 0.0010 ND 0.0010 ND 0.00096 NE bis(2-Ethylhexyl)phthalate EPA 625.1 117-81-7 66 mg/l ND 0.00076 NE Butylbenzylphthalate EPA 625.1 85-68-7 67 mg/l ND 0.00076 NE Chrysene EPA 625.1 218-01-9 76 mg/l ND 0.00020 NE Dibenz(a,h)anthracene EPA 625.1 53-70-3 82 mg/l ND 0.00055 ND 0.00055 ND 0.00053 NE Diethylphthalate EPA 625.1 84-66-2 70 mg/l ND 0.00058 ND 0.00058 ND 0.00056 NE Dimethylphthalate EPA 625.1 131-11-3 71 mg/l ND 0.00076 ND 0.00076 ND 0.00073 NE Di-n-butylphthalate EPA 625.1 84-74-2 68 mg/l ND 0.00075 ND 0.00075 ND 0.00072 NE Di-n-octylphthalate EPA 625.1 117-84-0 69 mg/l ND 0.00063 NE Fluoranthene EPA 625.1 206-44-0 39 mg/l ND 0.00021 ND 0.00021 ND 0.00020 NE Fluorene EPA 625.1 86-73-7 80 mg/l ND 0.00021 ND 0.00021 ND 0.00020 NE Hexachloro-1,3-butadiene EPA 625.1 87-68-3 52 mg/l ND 0.00094 ND 0.00094 ND 0.00090 0.00044 Hexachlorobenzene EPA 625.1 118-74-1 9 mg/l ND 0.00072 ND 0.00072 ND 0.00069 NE Hexachlorocyclopentadiene EPA 625.1 77-47-4 53 mg/l ND 0.00088 ND 0.00088 ND 0.00085 NE Hexachloroethane EPA 625.1 67-72-1 12 mg/l ND 0.0011 ND 0.0011 ND 0.0011 NE Indeno(1,2,3-cd)pyrene EPA 625.1 193-39-5 83 mg/l ND 0.00029 ND 0.00029 ND 0.00028 NE Isophorone EPA 625.1 78-59-1 54 mg/l ND 0.00089 ND 0.00089 ND 0.00086 NE Naphthalene EPA 625.1 91-20-3 55 mg/l ND 0.00034 ND 0.00034 NE Nitrobenzene EPA 625.1 98-95-3 56 mg/l ND 0.0011 ND 0.0011 ND 0.0011 NE N-Nitrosodimethylamine EPA 625.1 62-75-9 61 mg/l ND 0.00091 ND 0.00091 ND 0.00088 NE N-Nitroso-di-n-propylamine EPA 625.1 621-64-7 63 mg/l ND 0.00099 ND 0.00099 ND 0.00095 NE N-Nitrosodiphenylamine EPA 625.1 86-30-6 62 mg/l ND 0.0010 ND 0.0010 ND 0.00096 NE 2,2'-Oxybis(1-chloropropane) 2 EPA 625.1 108-60-1 42 mg/l ND 0.00095 ND 0.00095 ND 0.00091 NE Pentachlorophenol EPA 625.1 87-86-5 64 mg/l ND 0.0046 ND 0.0046 ND 0.0044 NE Phenanthrene EPA 625.1 85-01-8 81 mg/l ND 0.00022 ND 0.00022 ND 0.00021 NE Phenol EPA 625.1 108-95-2 65 mg/l ND 0.0019 ND 0.0019 ND 0.0018 NE Pyrene EPA 625.1 129-00-0 84 mg/l ND 0.00019 ND 0.00018 NE Total PAHs 3 EPA 625.1 ----mg/l 0.0000028 Asbestos EPA 100.2 1332-21-4 116 mf/l ND 0.97 ND 0.24 ND 0.49 NE 2,3,7,8-TCDD 4 EPA 1613 1746-01-6 129 mg/l ND 0.00000001 ND 0.00000001 ND 0.00000001 5E-12 ND - The analyte was not detected above laboratory detection limits. Subscript indicates compound-specific MDL in mg/l. J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit. NE - Not established. 15A NCAC 2B acute standards for cadmium, chromium, copper, lead, silver, and zinc are calculated as hardness dependent using a hardness value of 36 mg/l. mf/l - million fibers per liter 1 - Total chlorinated benzenes are the sum of chlorobenzene, 1,2,3-trichlorobenzene, 1,2,4 trichlorobenzene, 1,3,5-trichlorobenzene, 1,2,3,4-tetrachlorobenzene, 1,2,3,5-tetrachlorobenzene, 1,2,4,5-tetrachlorobenzene, pentachlorobenzene, and hexachlorobenzene. 2 - Per EPA correspondence, 40 CFR 423 Appendix A Number 42 (misidentified as bis(2-Chloroisopropyl)ether) is associated with CAS Number 108-60-1 (2, 2’-oxybis (1-chloropropane)). 3 - Total PAHs are the sum of benzo(a)anthracene, benzo(a)pyrene, benzo(b)fluoranthene, benzo(k)fluoranthene, chrysene, dibenz(a,h)anthracene, and indeno(1,2,3-cd)pyrene detections. 4 - 2,3,7,8-Tetra-Chlorodibenzo-P-Dioxin 0.0011 J 0.0027 J 0.0011 J 0.0011 J 0.0026 J 0.0155 0.009 ND 0.0012 J 0.0048 J 0.0061 0.0057 0.0019 J 0.0022 J 0.0030 J 0.0012 J 0.0011 J 0.0098 J 0.0053 0.0013 J 0.0015 J 0.0017 J Table 2-6 Eastern Drainage Ditch Sediment Sample Analytical Results Alcoa/Badin Landfill Badin Business Park Facility Badin, North Carolina Sample ID Method CAS Units EPA Freshwater Sediment Ecological Screening Value (ESV)ABL-SD011-F005ABL-SD012-F005ABL-SD010-F005Location Depth Date Time Percent Moisture ASTM D2974-87 % PCB-1016 (Aroclor 1016)EPA 8082 12674-11-2 mg/kg ND 0.0218 ND 0.0265 ND 0.0218 NE PCB-1221 (Aroclor 1221)EPA 8082 11104-28-2 mg/kg ND 0.0218 ND 0.0265 ND 0.0218 NE PCB-1232 (Aroclor 1232)EPA 8082 11141-16-5 mg/kg ND 0.0218 ND 0.0265 ND 0.0218 NE PCB-1242 (Aroclor 1242)EPA 8082 53469-21-9 mg/kg ND 0.0218 ND 0.0265 ND 0.0218 NE PCB-1248 (Aroclor 1248)EPA 8082 12672-29-6 mg/kg ND 0.0218 ND 0.0265 ND 0.0218 NE PCB-1254 (Aroclor 1254)EPA 8082 11097-69-1 mg/kg ND 0.0218 ND 0.0265 ND 0.0218 NE PCB-1260 (Aroclor 1260)EPA 8082 11096-82-5 mg/kg ND 0.0218 ND 0.0265 ND 0.0218 NE Total Polychlorinated Biphenyls 1336-36-3 mg/kg 0.0598 1-Methylnaphthalene EPA 8270 90-12-0 mg/kg ND 0.0018 ND 0.0017 0.141 2-Methylnaphthalene EPA 8270 91-57-6 mg/kg ND 0.0016 0.0202 Acenaphthene EPA 8270 83-32-9 mg/kg ND 0.0022 0.0067 Acenaphthylene EPA 8270 208-96-8 mg/kg ND 0.0019 ND 0.0023 ND 0.0019 0.0059 Anthracene EPA 8270 120-12-7 mg/kg 0.057 Benzo(a)anthracene EPA 8270 56-55-3 mg/kg 0.108 Benzo(a)pyrene EPA 8270 50-32-8 mg/kg 0.15 Benzo(b)fluoranthene EPA 8270 205-99-2 mg/kg 0.19 Benzo(g,h,i)perylene EPA 8270 191-24-2 mg/kg 0.17 Benzo(k)fluoranthene EPA 8270 207-08-9 mg/kg 0.24 Chrysene EPA 8270 218-01-9 mg/kg 0.166 Dibenz(a,h)anthracene EPA 8270 53-70-3 mg/kg ND 0.0027 ND 0.0026 0.033 Fluoranthene EPA 8270 206-44-0 mg/kg 0.423 Fluorene EPA 8270 86-73-7 mg/kg ND 0.0023 0.077 Indeno(1,2,3-cd)pyrene EPA 8270 193-39-5 mg/kg 0.2 Naphthalene EPA 8270 91-20-3 mg/kg ND 0.0034 ND 0.0033 0.176 Phenanthrene EPA 8270 85-01-8 mg/kg 0.204 Pyrene EPA 8270 129-00-0 mg/kg 0.195 Total Low Molecular Weight PAHs 0.6 Total High Molecular Weight PAHs 1 Total Polycyclic Aromatic Hydrocarbons 1.61 Sample times inadvertently left off laboratory chain of custody. Sample times as recorded on bottles were documented in field book. ND - The analyte was not detected above laboratory detection limits. Subscript indicates compound-specific MDL in mg/kg. J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit. ESV derived from Region 4 Ecological Risk Assessment Supplemental Guidance - March 2018 Update NE - Not established. 0.04556 0.3531 2.4741 0.3518 0.0176 0.1526 NDND 0.3691 0.0445 0.0539 0.0028 J 0.0217 0.0295 0.0456 0.0419 0.0230 0.0158 0.0372 0.0027 J 0.0042 J 0.0262 32.8 0.0023 J 0.0035 J 0.0074 J 0.0400 ND 7/11/2018 13:45 SurfaceSurface 42.4 31.2 7/11/2018 13:10 7/11/2018 12:35 Middle Ditch Upper Ditch Surface Lower Ditch 0.0563 0.287 0.319 0.286 0.146 0.109 0.254 0.381 0.137 0.235 0.0215 0.307 2.5909 0.0036 J 0.0171 0.0191 0.0176 0.0100 J 0.0080 J 0.0162 0.0232 0.0093 J 0.0140 J 0.0181 0.1562 0.0059 J 0.0131 J Table 2-7 Eastern Drainage Ditch Sediment Sample Analytical Results - Congener Analysis Alcoa/Badin Landfill Badin Business Park Facility Badin, North Carolina Sample ID Congener Number IUPAC Name Method CAS Units EPA Freshwater Sediment Ecological Screening Value (ESV)ABL-SD010-F005ABL-SD011-F005ABL-SD012-F005Location Depth Date Time 2-MoCB 1 2-Chlorobiphenyl EPA 1668A 2051-60-7 mg/kg ND 0.000025 ND 0.000025 ND 0.000025 NE 3-MoCB 2 3-Chlorobiphenyl EPA 1668A 2051-61-8 mg/kg ND 0.000025 ND 0.000025 ND 0.000025 NE 4-MoCB 3 4-Chlorobiphenyl EPA 1668A 2051-62-9 mg/kg ND 0.000025 ND 0.000025 ND 0.000025 NE 2,2'-DiCB 4 2,2'-Dichlorobiphenyl EPA 1668A 13029-08-8 mg/kg ND 0.000025 NE 2,6-DiCB 10 2,6-Dichlorobiphenyl EPA 1668A 33146-45-1 mg/kg ND 0.000025 ND 0.000025 ND 0.000025 NE 2,5-DiCB 9 2,5-Dichlorobiphenyl EPA 1668A 34883-39-1 mg/kg ND 0.000025 ND 0.000025 ND 0.000025 NE 2,4-DiCB 7 2,4-Dichlorobiphenyl EPA 1668A 33284-50-3 mg/kg ND 0.000025 ND 0.000025 ND 0.000025 NE 2,3'-DiCB 6 2,3'-Dichlorobiphenyl EPA 1668A 25569-80-6 mg/kg ND 0.000025 ND 0.000025 NE 2,3-DiCB 5 2,3-Dichlorobiphenyl EPA 1668A 16605-91-7 mg/kg ND 0.000025 ND 0.000025 ND 0.000025 NE 2,4'-DiCB 8 2,4'-Dichlorobiphenyl EPA 1668A 34883-43-7 mg/kg ND 0.000025 NE 3,5-DiCB 14 3,5-Dichlorobiphenyl EPA 1668A 34883-41-5 mg/kg ND 0.000025 ND 0.000025 ND 0.000025 NE 3,3'-DiCB 11 3,3'-Dichlorobiphenyl EPA 1668A 2050-67-1 mg/kg ND 0.000245 ND 0.000245 ND 0.000245 NE (12/13)12/13 NA (Co-elution)EPA 1668A E52450566 mg/kg ND 0.00005 ND 0.00005 ND 0.00005 NE 4,4'-DiCB 15 4,4'-Dichlorobiphenyl EPA 1668A 2050-68-2 mg/kg ND 0.000033 NE 2,2',6-TrCB 19 2,2',6-Trichlorobiphenyl EPA 1668A 38444-73-4 mg/kg ND 0.000025 ND 0.000025 NE (18/30)18/30 NA (Co-elution)EPA 1668A E52450574 mg/kg ND 0.00005 ND 0.00005 NE 2,2',4-TrCB 17 2,2',4-Trichlorobiphenyl EPA 1668A 37680-66-3 mg/kg ND 0.000025 NE 2,3',6-TrCB 27 2,3',6-Trichlorobiphenyl EPA 1668A 38444-76-7 mg/kg ND 0.000025 ND 0.000025 NE 2,3,6-TrCB 24 2,3,6-Trichlorobiphenyl EPA 1668A 55702-45-9 mg/kg ND 0.000025 ND 0.000025 ND 0.000025 NE 2,2',3-TrCB 16 2,2',3-Trichlorobiphenyl EPA 1668A 38444-78-9 mg/kg ND 0.000025 ND 0.000025 NE 2,4',6-TrCB 32 2,4',6-Trichlorobiphenyl EPA 1668A 38444-77-8 mg/kg ND 0.000025 NE 2,3',5'-TrCB 34 2,3',5'-Trichlorobiphenyl EPA 1668A 37680-68-5 mg/kg ND 0.000025 ND 0.000025 ND 0.000025 NE 2,3,5-TrCB 23 2,3,5-Trichlorobiphenyl EPA 1668A 55720-44-0 mg/kg ND 0.000025 ND 0.000025 ND 0.000025 NE (26/29)26/29 NA (Co-elution)EPA 1668A E52450608 mg/kg ND 0.00005 ND 0.00005 NE 2,3',4-TrCB 25 2,3',4-Trichlorobiphenyl EPA 1668A 55712-37-3 mg/kg ND 0.000025 ND 0.000025 NE 2,4',5-TrCB 31 2,4',5-Trichlorobiphenyl EPA 1668A 16606-02-3 mg/kg ND 0.00013 NE (20/28)20/28 NA (Co-elution)EPA 1668A E52450582 mg/kg ND 0.000129 NE (21/33)21/33 NA (Co-elution)EPA 1668A E52450590 mg/kg ND 0.000135 ND 0.000135 NE 2,3,4'-TrCB 22 2,3,4'-Trichlorobiphenyl EPA 1668A 38444-85-8 mg/kg ND 0.000095 ND 0.000095 NE 3,3',5-TrCB 36 3,3',5-Trichlorobiphenyl EPA 1668A 38444-87-0 mg/kg ND 0.000025 ND 0.000025 ND 0.000025 NE 3,4',5-TrCB 39 3,4',5-Trichlorobiphenyl EPA 1668A 38444-88-1 mg/kg ND 0.000025 ND 0.000025 ND 0.000025 NE 3,4,5-TrCB 38 3,4,5-Trichlorobiphenyl EPA 1668A 53555-66-1 mg/kg ND 0.000025 ND 0.000025 ND 0.000025 NE 3,3',4-TrCB 35 3,3',4-Trichlorobiphenyl EPA 1668A 37680-69-6 mg/kg ND 0.000025 ND 0.000025 ND 0.000025 NE 3,4,4'-TrCB 37 3,4,4'-Trichlorobiphenyl EPA 1668A 38444-90-5 mg/kg ND 0.000053 NE 2,2',6,6'-TeCB 54 2,2',6,6'-Tetrachlorobiphenyl EPA 1668A 15968-05-5 mg/kg ND 0.00005 ND 0.00005 ND 0.00005 NE (50/53)50/53 NA (Co-elution)EPA 1668A E52450657 mg/kg ND 0.0001 NE (45/51)45/51 NA (Co-elution)EPA 1668A E52450632 mg/kg ND 0.0001 NE 2,2',3,6'-TeCB 46 2,2',3,6'-Tetrachlorobiphenyl EPA 1668A 41464-47-5 mg/kg ND 0.00005 ND 0.00005 NE 2,2',5,5'-TeCB 52 2,2',5,5'-Tetrachlorobiphenyl EPA 1668A 35693-99-3 mg/kg ND 0.000154 NE 2,3',5',6-TeCB 73 2,3',5',6-Tetrachlorobiphenyl EPA 1668A 74338-23-1 mg/kg ND 0.00005 ND 0.00005 ND 0.00005 NE 43/73 43/73 NA (Co-elution)EPA 1668A mg/kg ND 0.00005 ND 0.00005 NE (49/69)49/69 NA (Co-elution)EPA 1668A E52450640 mg/kg ND 0.0001 NE 2,2',4,5-TeCB 48 2,2',4,5-Tetrachlorobiphenyl EPA 1668A 70362-47-9 mg/kg ND 0.00005 NE (44/47/65)44/47/65 NA (Co-elution)EPA 1668A E52450624 mg/kg ND 0.00015 NE (59/62/75)59/62/75 NA (Co-elution)EPA 1668A E52450665 mg/kg ND 0.00015 ND 0.00015 NE 2,2',3,4'-TeCB 42 2,2',3,4'-Tetrachlorobiphenyl EPA 1668A 36559-22-5 mg/kg ND 0.00005 NE (40/41/71)40/41/71 NA (Co-elution)EPA 1668A E52450616 mg/kg ND 0.00015 NE 2,3,4',6-TeCB 64 2,3,4',6-Tetrachlorobiphenyl EPA 1668A 52663-58-8 mg/kg ND 0.00005 NE 2,3',5,5'-TeCB 72 2,3',5,5'-Tetrachlorobiphenyl EPA 1668A 41464-42-0 mg/kg ND 0.00005 ND 0.00005 ND 0.00005 NE 2,3',4,5'-TeCB 68 2,3',4,5'-Tetrachlorobiphenyl EPA 1668A 73575-52-7 mg/kg ND 0.00005 ND 0.00005 ND 0.00005 NE 2,3,3',5-TeCB 57 2,3,3',5-Tetrachlorobiphenyl EPA 1668A 70424-67-8 mg/kg ND 0.00005 ND 0.00005 ND 0.00005 NE 2,3,3',5'-TeCB 58 2,3,3',5'-Tetrachlorobiphenyl EPA 1668A 41464-49-7 mg/kg ND 0.00005 ND 0.00005 ND 0.00005 NE 2,3',4,5-TeCB 67 2,3',4,5-Tetrachlorobiphenyl EPA 1668A 73575-53-8 mg/kg ND 0.00005 ND 0.00005 NE 2,3,4',5-TeCB 63 2,3,4',5-Tetrachlorobiphenyl EPA 1668A 74472-34-7 mg/kg ND 0.00005 NE (61/70/74/76)60/70/74/76 NA (Co-elution)EPA 1668A E52450673 mg/kg ND 0.0002 NE 2,3',4,4'-TeCB 66 2,3',4,4'-Tetrachlorobiphenyl EPA 1668A 32598-10-0 mg/kg ND 0.000084 NE 2,3,3',4-TeCB 55 2,3,3',4-Tetrachlorobiphenyl EPA 1668A 74338-24-2 mg/kg ND 0.00005 ND 0.00005 ND 0.00005 NE 2,3,3',4'-TeCB 56 2,3,3',4'-Tetrachlorobiphenyl EPA 1668A 41464-43-1 mg/kg ND 0.00005 NE 2,3,4,4'-TeCB 60 2,3,4,4'-Tetrachlorobiphenyl EPA 1668A 33025-41-1 mg/kg ND 0.00005 NE 3,3',5,5'-TeCB 80 3,3',5,5'-Tetrachlorobiphenyl EPA 1668A 33284-52-5 mg/kg ND 0.00005 ND 0.00005 ND 0.00005 NE 3,3',4,5'-TeCB 79 3,3',4,5'-Tetrachlorobiphenyl EPA 1668A 41464-48-6 mg/kg ND 0.00005 ND 0.00005 ND 0.00005 NE 3,3',4,5-TeCB 78 3,3',4,5-Tetrachlorobiphenyl EPA 1668A 70362-49-1 mg/kg ND 0.00005 ND 0.00005 ND 0.00005 NE 3,4,4',5-TeCB 81 3,4,4',5-Tetrachlorobiphenyl EPA 1668A 70362-50-4 mg/kg ND 0.00005 ND 0.00005 ND 0.00005 NE 3,3',4,4'-TeCB 77 3,3',4,4'-Tetrachlorobiphenyl EPA 1668A 32598-13-3 mg/kg ND 0.00005 NE 2,2',4,6,6'-PeCB 104 2,2',4,6,6'-Pentachlorobiphenyl EPA 1668A 56558-16-8 mg/kg ND 0.00005 ND 0.00005 ND 0.00005 NE 2,2',3,6,6'-PeCB 96 2,2',3,6,6'-Pentachlorobiphenyl EPA 1668A 73575-54-9 mg/kg ND 0.00005 ND 0.00005 ND 0.00005 NE 2,2',4,5',6-PeCB 103 2,2',4,5',6-Pentachlorobiphenyl EPA 1668A 60145-21-3 mg/kg ND 0.00005 ND 0.00005 ND 0.00005 NE 2,2',3,5,6'-PeCB 94 2,2',3,5,6'-Pentachlorobiphenyl EPA 1668A 73575-55-0 mg/kg ND 0.00005 ND 0.00005 ND 0.00005 NE 2,2',3,5',6-PeCB 95 2,2',3,5',6-Pentachlorobiphenyl EPA 1668A 38379-99-6 mg/kg ND 0.000095 NE (93/98/100/102)93/98/100/102 NA (Co-elution)EPA 1668A mg/kg ND 0.0002 ND 0.0002 NE (88/91)88/91 NA (Co-elution)EPA 1668A E52450715 mg/kg ND 0.0001 NE 2,2',3,3',6-PeCB 84 2,2',3,3',6-Pentachlorobiphenyl EPA 1668A 52663-60-2 mg/kg ND 0.00005 NE 2,2',3,4,6'-PeCB 89 2,2',3,4,6'-Pentachlorobiphenyl EPA 1668A 73575-57-2 mg/kg ND 0.00005 ND 0.00005 NE 2,3',4,5',6-PeCB 121 2,3',4,5',6-Pentachlorobiphenyl EPA 1668A 56558-18-0 mg/kg ND 0.00005 ND 0.00005 ND 0.00005 NE 2,2',3,5,5'-PeCB 92 2,2',3,5,5'-Pentachlorobiphenyl EPA 1668A 52663-61-3 mg/kg ND 0.00005 NE (90/101/113)90/101/113 NA (Co-elution)EPA 1668A E52450723 mg/kg ND 0.00015 NE 2,2',3,3',5-PeCB 83 2,2',3,3',5-Pentachlorobiphenyl EPA 1668A 60145-20-2 mg/kg ND 0.00005 ND 0.00005 NE 2,2',4,4',5-PeCB 99 2,2',4,4',5-Pentachlorobiphenyl EPA 1668A 38380-01-7 mg/kg ND 0.00005 NE 2,3,3',5,6-PeCB 112 2,3,3',5,6-Pentachlorobiphenyl EPA 1668A 74472-36-9 mg/kg ND 0.00005 ND 0.00005 ND 0.00005 NE (86/87/97/108/119/125)86/87/97/108/119'125 NA (Co-elution)EPA 1668A E52450707 mg/kg ND 0.0003 NE (85/117/116)85/117/116 NA (Co-elution)EPA 1668A E52450699 mg/kg ND 0.00015 NE (110/115)110/115 NA (Co-elution)EPA 1668A E52450756 mg/kg ND 0.0001 NE 2,2',3,3',4-PeCB 82 2,2',3,3',4-Pentachlorobiphenyl EPA 1668A 52663-62-4 mg/kg ND 0.00005 NE 2,3,3',5,5'-PeCB 111 2,3,3',5,5'-Pentachlorobiphenyl EPA 1668A 39635-32-0 mg/kg ND 0.00005 ND 0.00005 ND 0.00005 NE 2,3',4,5,5'-PeCB 120 2,3',4,5,5'-Pentachlorobiphenyl EPA 1668A 68194-12-7 mg/kg ND 0.00005 ND 0.00005 ND 0.00005 NE (107/124)107/124 NA (Co-elution)EPA 1668A E52450749 mg/kg ND 0.0001 ND 0.0001 NE 2,3,3',4,6-PeCB 109 2,3,3',4,6-Pentachlorobiphenyl EPA 1668A 74472-35-8 mg/kg ND 0.00005 NE 2,3',4,4',5'-PeCB 123 2,3',4,4',5'-Pentachlorobiphenyl EPA 1668A 65510-44-3 mg/kg ND 0.00005 ND 0.00005 NE 2,3,3',4,5-PeCB 106 2,3,3',4,5-Pentachlorobiphenyl EPA 1668A 70424-69-0 mg/kg ND 0.00005 ND 0.00005 ND 0.00005 NE 2,3',4,4',5-PeCB 118 2,3',4,4',5-Pentachlorobiphenyl EPA 1668A 31508-00-6 mg/kg ND 0.000064 NE 2,3,3',4',5'-PeCB 122 2,3,3',4',5'-Pentachlorobiphenyl EPA 1668A 76842-07-4 mg/kg ND 0.00005 ND 0.00005 NE 2,3,4,4',5-PeCB 114 2,3,4,4',5-Pentachlorobiphenyl EPA 1668A 74472-37-0 mg/kg ND 0.00005 ND 0.00005 NE 2,3,3',4,4'-PeCB 105 2,3,3',4,4'-Pentachlorobiphenyl EPA 1668A 32598-14-4 mg/kg ND 0.00005 NE 3,3',4,5,5'-PeCB 127 3,3',4,5,5'-Pentachlorobiphenyl EPA 1668A 39635-33-1 mg/kg ND 0.00005 ND 0.00005 ND 0.00005 NE 3,3',4,4',5-PeCB 126 3,3',4,4',5-Pentachlorobiphenyl EPA 1668A 57465-28-8 mg/kg ND 0.00005 ND 0.00005 ND 0.00005 NE 2,2',4,4',6,6'-HxCB 155 2,2',4,4',6,6'-Hexachlorobiphenyl EPA 1668A 33979-03-2 mg/kg ND 0.00005 ND 0.00005 ND 0.00005 NE 2,2',3,5,6,6'-HxCB 152 2,2',3,5,6,6'-Hexachlorobiphenyl EPA 1668A 68194-09-2 mg/kg ND 0.00005 ND 0.00005 ND 0.00005 NE 2,2',3,4',6,6'-HxCB 150 2,2',3,4',6,6'-Hexachlorobiphenyl EPA 1668A 68194-08-1 mg/kg ND 0.00005 ND 0.00005 ND 0.00005 NE 2,2',3,3',6,6'-HxCB 136 2,2',3,3',6,6'-Hexachlorobiphenyl EPA 1668A 38411-22-2 mg/kg ND 0.00005 ND 0.00005 NE 2,2',3,4,6,6'-HxCB 145 2,2',3,4,6,6'-Hexachlorobiphenyl EPA 1668A 74472-40-5 mg/kg ND 0.00005 ND 0.00005 ND 0.00005 NE 2,2',3,4',5,6'-HxCB 148 2,2',3,4',5,6'-Hexachlorobiphenyl EPA 1668A 74472-41-6 mg/kg ND 0.00005 ND 0.00005 ND 0.00005 NE (135/151)135/151 NA (Co-elution)EPA 1668A mg/kg ND 0.0001 NE 2,2',4,4',5,6'-HxCB 154 2,2',4,4',5,6'-Hexachlorobiphenyl EPA 1668A 60145-22-4 mg/kg ND 0.00005 ND 0.00005 NE 2,2',3,4,5',6-HxCB 144 2,2',3,4,5',6-Hexachlorobiphenyl EPA 1668A 68194-14-9 mg/kg ND 0.00005 ND 0.00005 NE (147/149)147/149 NA (Co-elution)EPA 1668A E52450814 mg/kg ND 0.0001 NE (134/143)134/143 NA (Co-elution)EPA 1668A E52450780 mg/kg ND 0.0001 ND 0.0001 NE (139/140)139/140 NA (Co-elution)EPA 1668A E52450806 mg/kg ND 0.0001 ND 0.0001 ND 0.0001 NE 2,2',3,3',4,6-HxCB 131 2,2',3,3',4,6-Hexachlorobiphenyl EPA 1668A 61798-70-7 mg/kg ND 0.00005 ND 0.00005 NE 2,2',3,4,5,6-HxCB 142 2,2',3,4,5,6-Hexachlorobiphenyl EPA 1668A 41411-61-4 mg/kg ND 0.00005 ND 0.00005 ND 0.00005 NE 2,2',3,3',4,6'-HxCB 132 2,2',3,3',4,6'-Hexachlorobiphenyl EPA 1668A 38380-05-1 mg/kg ND 0.00005 NE 2,2',3,3',5,5'-HxCB 133 2,2',3,3',5,5'-Hexachlorobiphenyl EPA 1668A 35694-04-3 mg/kg ND 0.00005 ND 0.00005 NE 0.000033 0.000159 0.000289 0.000179 0.000105 0.000101 0.000316 0.0000421 0.000123 0.000278 0.000165 0.0000423 0.00049 0.000369 0.00052 0.00148 0.00132 0.0000749 0.00277 0.000118 0.000387 0.000361 0.000733 0.000207 0.00244 0.000458 0.00176 0.00605 0.000172 0.0000634 0.00146 0.00124 0.00231 0.000534 0.000979 0.00158 0.00387 0.000884 0.0000882 0.000709 0.000612 0.000239 0.00157 0.00348 0.00288 0.000377 0.00615 0.000297 0.000545 0.000305 0.000797 0.00529 0.00296 0.0044 0.000388 0.000162 0.0081 0.00117 0.0318 0.00229 0.0000614 0.0153 0.00045 0.0085 0.00021 0.000114 0.000408 0.000147 0.000287 0.000495 0.000439 0.000264 0.000768 0.000104 0.000123 0.000601 0.00156 0.00104 0.000379 0.000177 0.000097 0.0000608 0.000681 0.000715 0.00018 0.000334 0.000426 0.0000516 0.0000668 0.000108 0.0000652 0.000102 0.0000817 0.000354 0.000535 0.00011 0.000114 0.000111 0.000821 0.000574 0.000122 0.000378 0.00014 0.000145 13:45 13:10 12:35 7/11/2018 7/11/2018 7/11/2018 Surface Surface Surface Lower Ditch Middle Ditch Upper Ditch Table 2-7 Eastern Drainage Ditch Sediment Sample Analytical Results - Congener Analysis Alcoa/Badin Landfill Badin Business Park Facility Badin, North Carolina Sample ID Congener Number IUPAC Name Method CAS Units EPA Freshwater Sediment Ecological Screening Value (ESV)ABL-SD010-F005ABL-SD011-F005ABL-SD012-F005Location Depth Date Time 13:45 13:10 12:35 7/11/2018 7/11/2018 7/11/2018 Surface Surface Surface Lower Ditch Middle Ditch Upper Ditch 2,3,3',5,5',6-HxCB 165 2,3,3',5,5',6-Hexachlorobiphenyl EPA 1668A 74472-46-1 mg/kg ND 0.00005 ND 0.00005 NE 2,2',3,4',5,5'-HxCB 146 2,2',3,4',5,5'-Hexachlorobiphenyl EPA 1668A 51908-16-8 mg/kg ND 0.00005 NE 2,3,3',4,5',6-HxCB 161 2,3,3',4,5',6-Hexachlorobiphenyl EPA 1668A 74472-43-8 mg/kg ND 0.00005 ND 0.00005 ND 0.00005 NE (153/168)153/168 NA (Co-elution)EPA 1668A E52450822 mg/kg NE 2,2',3,4,5,5'-HxCB 141 2,2',3,4,5,5'-Hexachlorobiphenyl EPA 1668A 52712-04-6 mg/kg ND 0.00005 NE 2,2',3,3',4,5'-HxCB 130 2,2',3,3',4,5'-Hexachlorobiphenyl EPA 1668A 52663-66-8 mg/kg ND 0.00005 ND 0.00005 NE 2,2',3,4,4',5-HxCB 137 2,2',3,4,4',5-Hexachlorobiphenyl EPA 1668A 35694-06-5 mg/kg ND 0.00005 ND 0.00005 NE 2,3,3',4',5',6-HxCB 164 2,3,3',4',5',6-Hexachlorobiphenyl EPA 1668A 74472-45-0 mg/kg ND 0.00005 ND 0.00005 NE (129/138/163)129/138/163 NA (Co-elution)EPA 1668A mg/kg NE 2,3,3',4,5,6-HxCB 160 2,3,3',4,5,6-Hexachlorobiphenyl EPA 1668A 41411-62-5 mg/kg ND 0.00005 ND 0.00005 ND 0.00005 NE 2,3,3',4,4',6-HxCB 158 2,3,3',4,4',6-Hexachlorobiphenyl EPA 1668A 74472-42-7 mg/kg ND 0.00005 ND 0.00005 NE (128/166)128/166 NA (Co-elution)EPA 1668A E52450764 mg/kg ND 0.0001 ND 0.0001 NE 2,3,3',4,5,5'-HxCB 159 2,3,3',4,5,5'-Hexachlorobiphenyl EPA 1668A 39635-35-3 mg/kg ND 0.00005 ND 0.00005 NE 2,3,3',4',5,5'-HxCB 162 2,3,3',4',5,5'-Hexachlorobiphenyl EPA 1668A 39635-34-2 mg/kg ND 0.00005 ND 0.00005 ND 0.00005 NE 2,3',4,4',5,5'-HxCB 167 2,3',4,4',5,5'-Hexachlorobiphenyl EPA 1668A 52663-72-6 mg/kg ND 0.00005 ND 0.00005 NE (156/157)156/157 NA (Co-elution)EPA 1668A E52450830 mg/kg ND 0.0001 ND 0.0001 NE 3,3',4,4',5,5'-HxCB 169 3,3',4,4',5,5'-Hexachlorobiphenyl EPA 1668A 32774-16-6 mg/kg ND 0.00005 ND 0.00005 NE 2,2',3,4',5,6,6'-HpCB 188 2,2',3,4',5,6,6'-Heptachlorobiphenyl EPA 1668A 74487-85-7 mg/kg ND 0.00005 ND 0.00005 ND 0.00005 NE 2,2',3,3',5,6,6'-HpCB 179 2,2',3,3',5,6,6'-Heptachlorobiphenyl EPA 1668A 52663-64-6 mg/kg ND 0.00005 NE 2,2',3,4,4',6,6'-HpCB 184 2,2',3,4,4',6,6'-Heptachlorobiphenyl EPA 1668A 74472-48-3 mg/kg ND 0.00005 ND 0.00005 ND 0.00005 NE 2,2',3,3',4,6,6'-HpCB 176 2,2',3,3',4,6,6'-Heptachlorobiphenyl EPA 1668A 52663-65-7 mg/kg ND 0.00005 ND 0.00005 NE 2,2',3,4,5,6,6'-HpCB 186 2,2',3,4,5,6,6'-Heptachlorobiphenyl EPA 1668A 74472-49-4 mg/kg ND 0.00005 ND 0.00005 ND 0.00005 NE 2,2',3,3',5,5',6-HpCB 178 2,2',3,3',5,5',6-Heptachlorobiphenyl EPA 1668A 52663-67-9 mg/kg ND 0.00005 ND 0.00005 NE 2,2',3,3',4,5',6-HpCB 175 2,2',3,3',4,5',6-Heptachlorobiphenyl EPA 1668A 40186-70-7 mg/kg ND 0.00005 ND 0.00005 NE 2,2',3,4',5,5',6-HpCB 187 2,2',3,4',5,5',6-Heptachlorobiphenyl EPA 1668A 52663-68-0 mg/kg NE 2,2',3,4,4',5,6'-HpCB 182 2,2',3,4,4',5,6'-Heptachlorobiphenyl EPA 1668A 60145-23-5 mg/kg ND 0.00005 ND 0.00005 ND 0.00005 NE (183/185)183/185 NA (Co-elution)EPA 1668A E52450863 mg/kg ND 0.0001 ND 0.0001 NE 2,2',3,3',4,5,6'-HpCB 174 2,2',3,3',4,5,6'-Heptachlorobiphenyl EPA 1668A 38411-25-5 mg/kg ND 0.00005 NE 2,2',3,3',4,5',6'-HpCB 177 2,2',3,3',4,5',6'-Heptachlorobiphenyl EPA 1668A 52663-70-4 mg/kg ND 0.00005 NE 2,2',3,4,4',5,6-HpCB 181 2,2',3,4,4',5,6-Heptachlorobiphenyl EPA 1668A 74472-47-2 mg/kg ND 0.00005 ND 0.00005 NE (171/173)171/173 NA (Co-elution)EPA 1668A E52450848 mg/kg ND 0.0001 ND 0.0001 NE 2,2',3,3',4,5,5'-HpCB 172 2,2',3,3',4,5,5'-Heptachlorobiphenyl EPA 1668A 52663-74-8 mg/kg ND 0.00005 ND 0.00005 NE 2,3,3',4,5,5',6-HpCB 192 2,3,3',4,5,5',6-Heptachlorobiphenyl EPA 1668A 74472-51-8 mg/kg ND 0.00005 ND 0.00005 ND 0.00005 NE (180/193)180/193 NA (Co-elution)EPA 1668A E52450855 mg/kg NE 2,3,3',4,4',5',6-HpCB 191 2,3,3',4,4',5',6-Heptachlorobiphenyl EPA 1668A 74472-50-7 mg/kg ND 0.00005 ND 0.00005 NE 2,2',3,3',4,4',5-HpCB 170 2,2',3,3',4,4',5-Heptachlorobiphenyl EPA 1668A 35065-30-6 mg/kg ND 0.00005 NE 2,3,3',4,4',5,6-HpCB 190 2,3,3',4,4',5,6-Heptachlorobiphenyl EPA 1668A 41411-64-7 mg/kg ND 0.00005 ND 0.00005 NE 2,3,3',4,4',5,5'-HpCB 189 2,3,3',4,4',5,5'-Heptachlorobiphenyl EPA 1668A 39635-31-9 mg/kg ND 0.00005 ND 0.00005 NE 2,2',3,3',5,5',6,6'-OcCB 202 2,2',3,3',5,5',6,6'-Octachlorobiphenyl EPA 1668A 2136-99-4 mg/kg ND 0.000075 ND 0.000075 NE 2,2',3,3',4,5',6,6'-OcCB 201 2,2',3,3',4,5',6,6'-Octachlorobiphenyl EPA 1668A 40186-71-8 mg/kg ND 0.000075 ND 0.000075 NE 2,2',3,4,4',5,6,6'-OcCB 204 2,2',3,4,4',5,6,6'-Octachlorobiphenyl EPA 1668A 74472-52-9 mg/kg ND 0.000075 ND 0.000075 ND 0.000075 NE (197/200)197/200 NA (Co-elution)EPA 1668A E52450871 mg/kg ND 0.00015 ND 0.00015 NE (198/199)198/199 NA (Co-elution)EPA 1668A E52450889 mg/kg ND 0.00015 ND 0.00015 NE 2,2',3,3',4,4',5,6'-OcCB 196 2,2',3,3',4,4',5,6'-Octachlorobiphenyl EPA 1668A 42740-50-1 mg/kg ND 0.000075 ND 0.000075 NE 2,2',3,4,4',5,5',6-OcCB 203 2,2',3,4,4',5,5',6-Octachlorobiphenyl EPA 1668A 52663-76-0 mg/kg ND 0.000075 ND 0.000075 NE 2,2',3,3',4,4',5,6-OcCB 195 2,2',3,3',4,4',5,6-Octachlorobiphenyl EPA 1668A 52663-78-2 mg/kg ND 0.000075 ND 0.000075 NE 2,2',3,3',4,4',5,5'-OcCB 194 2,2',3,3',4,4',5,5'-Octachlorobiphenyl EPA 1668A 35694-08-7 mg/kg ND 0.000075 ND 0.000075 NE 2,3,3',4,4',5,5',6-OcCB 205 2,3,3',4,4',5,5',6-Octachlorobiphenyl EPA 1668A 74472-53-0 mg/kg ND 0.000075 ND 0.000075 NE 2,2',3,3',4,5,5',6,6'-NoCB 208 2,2',3,3',4,5,5',6,6'-Nonachlorobiphenyl EPA 1668A 52663-77-1 mg/kg ND 0.000075 ND 0.000075 NE 2,2',3,3',4,4',5,6,6'-NoCB 207 2,2',3,3',4,4',5,6,6'-Nonachlorobiphenyl EPA 1668A 52663-79-3 mg/kg ND 0.000075 ND 0.000075 NE 2,2',3,3',4,4',5,5',6-NoCB 206 2,2',3,3',4,4',5,5',6-Nonachlorobiphenyl EPA 1668A 40186-72-9 mg/kg ND 0.000075 ND 0.000075 NE Decachlorobiphenyl 209 Decachlorobiphenyl EPA 1668A 2051-24-3 mg/kg ND 0.000075 ND 0.000075 NE Total Polychlorinated Biphenyls mg/kg 0.0598/0.014 Sample times inadvertently left off laboratory chain of custody. Sample times as recorded on bottles were documented in field book. ND - The analyte was not detected above laboratory detection limits. Subscript indicates compound-specific Method Specified Reporting Limit (EML) in mg/kg. ESV derived from Region 4 Ecological Risk Assessment Supplemental Guidance - March 2018 Update include both aquatic and wildlife based values. NE - Not established. 0.00615 0.000223 0.00432 0.00397 0.0495 0.000214 0.000187 0.0012 0.000386 0.00262 0.0132 0.056 0.0185 0.000165 I 0.00383 0.0013 0.00168 0.0591 0.0000609 0.00189 0.00967 0.00589 0.0129 0.0000749 0.0266 0.0461 0.0352 0.0436 0.00203 0.119 0.00807 0.000117 0.000111 0.000113 0.00666 0.00117 0.00143 0.0015 0.0317 0.013 0.0202 0.0177 0.0351 0.00541 0.00462 0.00554 0.00157 0.0112 0.000189 0.000126 0.0000779 0.000263 0.0000663 0.000408 0.0000697 0.000497 0.0000514 0.0151384 0.8236752 0.0005789 Table 2-8 Eastern Drainage Ditch Surface Water Sample Analytical Results Alcoa/Badin Landfill Badin Business Park Facility Badin, North Carolina Sample ID Method CAS Units 15A NCAC 2B Surface Water StandardABL-SW013-F005ABL-SW014-F005ABL-SW015-F005Location Date Time Fluoride EPA 300.0 16984-48-8 mg/l 1.8 Cyanide EPA 9012B 57-12-5 mg/l 0.005 Available Cyanide OIA1677 mg/l NE PCB-1016 (Aroclor 1016)EPA 8082 12674-11-2 mg/l ND 0.00050 ND 0.00042 ND 0.00050 NE PCB-1221 (Aroclor 1221)EPA 8082 11104-28-2 mg/l ND 0.00050 ND 0.00042 ND 0.00050 NE PCB-1232 (Aroclor 1232)EPA 8082 11141-16-5 mg/l ND 0.00050 ND 0.00042 ND 0.00050 NE PCB-1242 (Aroclor 1242)EPA 8082 53469-21-9 mg/l ND 0.00050 ND 0.00042 ND 0.00050 NE PCB-1248 (Aroclor 1248)EPA 8082 12672-29-6 mg/l ND 0.00050 ND 0.00042 ND 0.00050 NE PCB-1254 (Aroclor 1254)EPA 8082 11097-69-1 mg/l ND 0.00050 ND 0.00042 ND 0.00050 NE PCB-1260 (Aroclor 1260)EPA 8082 11096-82-5 mg/l ND 0.00050 ND 0.00042 ND 0.00050 NE Total Polychlorinated Biphenyls 1336-36-3 mg/l 0.000001 1-Methylnaphthalene EPA 8270 90-12-0 mg/l ND 0.0020 ND 0.0020 ND 0.0020 NE 2-Methylnaphthalene EPA 8270 91-57-6 mg/l ND 0.0020 ND 0.0020 ND 0.0020 NE Acenaphthene EPA 8270 83-32-9 mg/l ND 0.00050 ND 0.00050 ND 0.00050 NE Acenaphthylene EPA 8270 208-96-8 mg/l ND 0.00050 ND 0.00050 ND 0.00050 NE Anthracene EPA 8270 120-12-7 mg/l ND 0.000050 ND 0.000050 ND 0.000050 NE Benzo(a)anthracene EPA 8270 56-55-3 mg/l ND 0.000050 ND 0.000050 ND 0.000050 NE Benzo(a)pyrene EPA 8270 50-32-8 mg/l ND 0.00010 ND 0.00010 ND 0.00010 NE Benzo(b)fluoranthene EPA 8270 205-99-2 mg/l ND 0.000050 ND 0.000050 ND 0.000050 NE Benzo(g,h,i)perylene EPA 8270 191-24-2 mg/l ND 0.00020 ND 0.00020 ND 0.00020 NE Benzo(k)fluoranthene EPA 8270 207-08-9 mg/l ND 0.00020 ND 0.00020 ND 0.00020 NE Chrysene EPA 8270 218-01-9 mg/l ND 0.00010 ND 0.00010 ND 0.00010 NE Dibenz(a,h)anthracene EPA 8270 53-70-3 mg/l ND 0.00015 ND 0.00015 ND 0.00015 NE Fluoranthene EPA 8270 206-44-0 mg/l ND 0.00030 ND 0.00030 ND 0.00030 NE Fluorene EPA 8270 86-73-7 mg/l ND 0.00031 ND 0.00031 ND 0.00031 NE Indeno(1,2,3-cd)pyrene EPA 8270 193-39-5 mg/l ND 0.000050 ND 0.000050 ND 0.000050 NE Naphthalene EPA 8270 91-20-3 mg/l ND 0.0015 ND 0.0015 ND 0.0015 NE Phenanthrene EPA 8270 85-01-8 mg/l ND 0.00020 ND 0.00020 ND 0.00020 NE Pyrene EPA 8270 129-00-0 mg/l ND 0.00010 ND 0.00010 ND 0.00010 NE Total PAHs 1 mg/l NE ND - The analyte was not detected above laboratory detection limits. Subscript indicates compound-specific MDL in mg/kg. J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit. NE - Not established.1 - Total PAHs are the sum of benzo(a)anthracene, benzo(a)pyrene, benzo(b)fluoranthene, benzo(k)fluoranthene, chrysene, dibenz(a,h)anthracene, and indeno(1,2,3-cd)pyrene detections. ND ND ND ND 0.064 0.0034 0.051 0.0038 ND 0.014 0.00080 J ND 1.2 2.2 6.0 7/11/2018 7/11/2018 7/11/2018 13:25 12:50 12:20 Lower Ditch Middle Ditch Upper Ditch Table 2-9 Eastern Drainage Ditch Surface Water Sample Analytical Results - Congener Analysis Alcoa/Badin Landfill Badin Business Park Facility Badin, North Carolina Sample ID Congener Number IUPAC Name Method CAS Units 15A NCAC 2B Surface Water StandardABL-SW013-F005ABL-SW014-F005ABL-SW015-F005Location Date Time 2-MoCB 1 2-Chlorobiphenyl EPA 1668A 2051-60-7 mg/l ND 0.000000261 ND 0.000000267 ND 0.000000259 NE 3-MoCB 2 3-Chlorobiphenyl EPA 1668A 2051-61-8 mg/l ND 0.000000261 ND 0.000000267 ND 0.000000259 NE 4-MoCB 3 4-Chlorobiphenyl EPA 1668A 2051-62-9 mg/l ND 0.000000261 ND 0.000000267 ND 0.000000259 NE 2,2'-DiCB 4 2,2'-Dichlorobiphenyl EPA 1668A 13029-08-8 mg/l ND 0.000000261 ND 0.000000267 ND 0.000000259 NE 2,6-DiCB 10 2,6-Dichlorobiphenyl EPA 1668A 33146-45-1 mg/l ND 0.000000261 ND 0.000000267 ND 0.000000259 NE 2,5-DiCB 9 2,5-Dichlorobiphenyl EPA 1668A 34883-39-1 mg/l ND 0.000000261 ND 0.000000267 ND 0.000000259 NE 2,4-DiCB 7 2,4-Dichlorobiphenyl EPA 1668A 33284-50-3 mg/l ND 0.000000261 ND 0.000000267 ND 0.000000259 NE 2,3'-DiCB 6 2,3'-Dichlorobiphenyl EPA 1668A 25569-80-6 mg/l ND 0.000000261 ND 0.000000267 ND 0.000000259 NE 2,3-DiCB 5 2,3-Dichlorobiphenyl EPA 1668A 16605-91-7 mg/l ND 0.000000261 ND 0.000000267 ND 0.000000259 NE 2,4'-DiCB 8 2,4'-Dichlorobiphenyl EPA 1668A 34883-43-7 mg/l ND 0.000000261 ND 0.000000267 ND 0.000000259 NE 3,5-DiCB 14 3,5-Dichlorobiphenyl EPA 1668A 34883-41-5 mg/l ND 0.000000261 ND 0.000000267 ND 0.000000259 NE 3,3'-DiCB 11 3,3'-Dichlorobiphenyl EPA 1668A 2050-67-1 mg/l ND 0.00000256 ND 0.00000262 ND 0.00000254 NE (12/13)12/13 NA (Co-elution)EPA 1668A E52450566 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 4,4'-DiCB 15 4,4'-Dichlorobiphenyl EPA 1668A 2050-68-2 mg/l ND 0.000000345 ND 0.000000353 ND 0.000000342 NE 2,2',6-TrCB 19 2,2',6-Trichlorobiphenyl EPA 1668A 38444-73-4 mg/l ND 0.000000261 ND 0.000000267 ND 0.000000259 NE (18/30)18/30 NA (Co-elution)EPA 1668A E52450574 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 2,2',4-TrCB 17 2,2',4-Trichlorobiphenyl EPA 1668A 37680-66-3 mg/l ND 0.000000261 ND 0.000000267 ND 0.000000259 NE 2,3',6-TrCB 27 2,3',6-Trichlorobiphenyl EPA 1668A 38444-76-7 mg/l ND 0.000000261 ND 0.000000267 ND 0.000000259 NE 2,3,6-TrCB 24 2,3,6-Trichlorobiphenyl EPA 1668A 55702-45-9 mg/l ND 0.000000261 ND 0.000000267 ND 0.000000259 NE 2,2',3-TrCB 16 2,2',3-Trichlorobiphenyl EPA 1668A 38444-78-9 mg/l ND 0.000000261 ND 0.000000267 ND 0.000000259 NE 2,4',6-TrCB 32 2,4',6-Trichlorobiphenyl EPA 1668A 38444-77-8 mg/l ND 0.000000261 ND 0.000000267 ND 0.000000259 NE 2,3',5'-TrCB 34 2,3',5'-Trichlorobiphenyl EPA 1668A 37680-68-5 mg/l ND 0.000000261 ND 0.000000267 ND 0.000000259 NE 2,3,5-TrCB 23 2,3,5-Trichlorobiphenyl EPA 1668A 55720-44-0 mg/l ND 0.000000261 ND 0.000000267 ND 0.000000259 NE (26/29)26/29 NA (Co-elution)EPA 1668A E52450608 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 2,3',4-TrCB 25 2,3',4-Trichlorobiphenyl EPA 1668A 55712-37-3 mg/l ND 0.000000261 ND 0.000000267 ND 0.000000259 NE 2,4',5-TrCB 31 2,4',5-Trichlorobiphenyl EPA 1668A 16606-02-3 mg/l ND 0.00000136 ND 0.00000139 ND 0.00000135 NE (20/28)20/28 NA (Co-elution)EPA 1668A E52450582 mg/l ND 0.00000135 ND 0.00000138 ND 0.00000134 NE (21/33)21/33 NA (Co-elution)EPA 1668A E52450590 mg/l ND 0.00000141 ND 0.00000144 ND 0.0000014 NE 2,3,4'-TrCB 22 2,3,4'-Trichlorobiphenyl EPA 1668A 38444-85-8 mg/l ND 0.000000994 ND 0.00000102 ND 0.000000985 NE 3,3',5-TrCB 36 3,3',5-Trichlorobiphenyl EPA 1668A 38444-87-0 mg/l ND 0.000000261 ND 0.000000267 ND 0.000000259 NE 3,4',5-TrCB 39 3,4',5-Trichlorobiphenyl EPA 1668A 38444-88-1 mg/l ND 0.000000261 ND 0.000000267 ND 0.000000259 NE 3,4,5-TrCB 38 3,4,5-Trichlorobiphenyl EPA 1668A 53555-66-1 mg/l ND 0.000000261 ND 0.000000267 ND 0.000000259 NE 3,3',4-TrCB 35 3,3',4-Trichlorobiphenyl EPA 1668A 37680-69-6 mg/l ND 0.000000261 ND 0.000000267 ND 0.000000259 NE 3,4,4'-TrCB 37 3,4,4'-Trichlorobiphenyl EPA 1668A 38444-90-5 mg/l ND 0.000000554 ND 0.000000567 ND 0.000000549 NE 2,2',6,6'-TeCB 54 2,2',6,6'-Tetrachlorobiphenyl EPA 1668A 15968-05-5 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE (50/53)50/53 NA (Co-elution)EPA 1668A E52450657 mg/l ND 0.00000105 ND 0.00000107 ND 0.00000104 NE (45/51)45/51 NA (Co-elution)EPA 1668A E52450632 mg/l ND 0.00000105 ND 0.00000107 ND 0.00000104 NE 2,2',3,6'-TeCB 46 2,2',3,6'-Tetrachlorobiphenyl EPA 1668A 41464-47-5 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 2,2',5,5'-TeCB 52 2,2',5,5'-Tetrachlorobiphenyl EPA 1668A 35693-99-3 mg/l ND 0.00000165 ND 0.0000016 NE 2,3',5',6-TeCB 73 2,3',5',6-Tetrachlorobiphenyl EPA 1668A 74338-23-1 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 43/73 43/73 NA (Co-elution)EPA 1668A mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE (49/69)49/69 NA (Co-elution)EPA 1668A E52450640 mg/l ND 0.00000107 ND 0.00000104 NE 2,2',4,5-TeCB 48 2,2',4,5-Tetrachlorobiphenyl EPA 1668A 70362-47-9 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE (44/47/65)44/47/65 NA (Co-elution)EPA 1668A E52450624 mg/l ND 0.00000157 ND 0.0000016 ND 0.00000155 NE (59/62/75)59/62/75 NA (Co-elution)EPA 1668A E52450665 mg/l ND 0.00000157 ND 0.0000016 ND 0.00000155 NE 2,2',3,4'-TeCB 42 2,2',3,4'-Tetrachlorobiphenyl EPA 1668A 36559-22-5 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE (40/41/71)40/41/71 NA (Co-elution)EPA 1668A E52450616 mg/l ND 0.00000157 ND 0.0000016 ND 0.00000155 NE 2,3,4',6-TeCB 64 2,3,4',6-Tetrachlorobiphenyl EPA 1668A 52663-58-8 mg/l NE 2,3',5,5'-TeCB 72 2,3',5,5'-Tetrachlorobiphenyl EPA 1668A 41464-42-0 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 2,3',4,5'-TeCB 68 2,3',4,5'-Tetrachlorobiphenyl EPA 1668A 73575-52-7 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 2,3,3',5-TeCB 57 2,3,3',5-Tetrachlorobiphenyl EPA 1668A 70424-67-8 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 2,3,3',5'-TeCB 58 2,3,3',5'-Tetrachlorobiphenyl EPA 1668A 41464-49-7 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 2,3',4,5-TeCB 67 2,3',4,5-Tetrachlorobiphenyl EPA 1668A 73575-53-8 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 2,3,4',5-TeCB 63 2,3,4',5-Tetrachlorobiphenyl EPA 1668A 74472-34-7 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE (61/70/74/76)60/70/74/76 NA (Co-elution)EPA 1668A E52450673 mg/l ND 0.00000214 ND 0.00000207 NE 2,3',4,4'-TeCB 66 2,3',4,4'-Tetrachlorobiphenyl EPA 1668A 32598-10-0 mg/l NE 2,3,3',4-TeCB 55 2,3,3',4-Tetrachlorobiphenyl EPA 1668A 74338-24-2 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 2,3,3',4'-TeCB 56 2,3,3',4'-Tetrachlorobiphenyl EPA 1668A 41464-43-1 mg/l ND 0.000000535 ND 0.000000518 NE 2,3,4,4'-TeCB 60 2,3,4,4'-Tetrachlorobiphenyl EPA 1668A 33025-41-1 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 3,3',5,5'-TeCB 80 3,3',5,5'-Tetrachlorobiphenyl EPA 1668A 33284-52-5 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 3,3',4,5'-TeCB 79 3,3',4,5'-Tetrachlorobiphenyl EPA 1668A 41464-48-6 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 3,3',4,5-TeCB 78 3,3',4,5-Tetrachlorobiphenyl EPA 1668A 70362-49-1 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 3,4,4',5-TeCB 81 3,4,4',5-Tetrachlorobiphenyl EPA 1668A 70362-50-4 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 3,3',4,4'-TeCB 77 3,3',4,4'-Tetrachlorobiphenyl EPA 1668A 32598-13-3 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 2,2',4,6,6'-PeCB 104 2,2',4,6,6'-Pentachlorobiphenyl EPA 1668A 56558-16-8 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 2,2',3,6,6'-PeCB 96 2,2',3,6,6'-Pentachlorobiphenyl EPA 1668A 73575-54-9 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 2,2',4,5',6-PeCB 103 2,2',4,5',6-Pentachlorobiphenyl EPA 1668A 60145-21-3 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 2,2',3,5,6'-PeCB 94 2,2',3,5,6'-Pentachlorobiphenyl EPA 1668A 73575-55-0 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 2,2',3,5',6-PeCB 95 2,2',3,5',6-Pentachlorobiphenyl EPA 1668A 38379-99-6 mg/l ND 0.000000994 ND 0.00000102 ND 0.000000985 NE (93/98/100/102)93/98/100/102 NA (Co-elution)EPA 1668A mg/l ND 0.00000209 ND 0.00000214 ND 0.00000207 NE (88/91)88/91 NA (Co-elution)EPA 1668A E52450715 mg/l ND 0.00000105 ND 0.00000107 ND 0.00000104 NE 2,2',3,3',6-PeCB 84 2,2',3,3',6-Pentachlorobiphenyl EPA 1668A 52663-60-2 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 2,2',3,4,6'-PeCB 89 2,2',3,4,6'-Pentachlorobiphenyl EPA 1668A 73575-57-2 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 2,3',4,5',6-PeCB 121 2,3',4,5',6-Pentachlorobiphenyl EPA 1668A 56558-18-0 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 2,2',3,5,5'-PeCB 92 2,2',3,5,5'-Pentachlorobiphenyl EPA 1668A 52663-61-3 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE (90/101/113)90/101/113 NA (Co-elution)EPA 1668A E52450723 mg/l ND 0.00000157 ND 0.0000016 ND 0.00000155 NE 2,2',3,3',5-PeCB 83 2,2',3,3',5-Pentachlorobiphenyl EPA 1668A 60145-20-2 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 2,2',4,4',5-PeCB 99 2,2',4,4',5-Pentachlorobiphenyl EPA 1668A 38380-01-7 mg/l ND 0.000000518 NE 2,3,3',5,6-PeCB 112 2,3,3',5,6-Pentachlorobiphenyl EPA 1668A 74472-36-9 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE (86/87/97/108/119/125)86/87/97/108/119'125 NA (Co-elution)EPA 1668A E52450707 mg/l ND 0.00000314 ND 0.00000321 ND 0.00000311 NE (85/117/116)85/117/116 NA (Co-elution)EPA 1668A E52450699 mg/l ND 0.00000157 ND 0.0000016 ND 0.00000155 NE (110/115)110/115 NA (Co-elution)EPA 1668A E52450756 mg/l ND 0.00000104 NE 2,2',3,3',4-PeCB 82 2,2',3,3',4-Pentachlorobiphenyl EPA 1668A 52663-62-4 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 2,3,3',5,5'-PeCB 111 2,3,3',5,5'-Pentachlorobiphenyl EPA 1668A 39635-32-0 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 2,3',4,5,5'-PeCB 120 2,3',4,5,5'-Pentachlorobiphenyl EPA 1668A 68194-12-7 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE (107/124)107/124 NA (Co-elution)EPA 1668A E52450749 mg/l ND 0.00000105 ND 0.00000107 ND 0.00000104 NE 2,3,3',4,6-PeCB 109 2,3,3',4,6-Pentachlorobiphenyl EPA 1668A 74472-35-8 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 2,3',4,4',5'-PeCB 123 2,3',4,4',5'-Pentachlorobiphenyl EPA 1668A 65510-44-3 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 2,3,3',4,5-PeCB 106 2,3,3',4,5-Pentachlorobiphenyl EPA 1668A 70424-69-0 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 2,3',4,4',5-PeCB 118 2,3',4,4',5-Pentachlorobiphenyl EPA 1668A 31508-00-6 mg/l ND 0.000000663 NE 2,3,3',4',5'-PeCB 122 2,3,3',4',5'-Pentachlorobiphenyl EPA 1668A 76842-07-4 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 2,3,4,4',5-PeCB 114 2,3,4,4',5-Pentachlorobiphenyl EPA 1668A 74472-37-0 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 2,3,3',4,4'-PeCB 105 2,3,3',4,4'-Pentachlorobiphenyl EPA 1668A 32598-14-4 mg/l ND 0.000000535 ND 0.000000518 NE 3,3',4,5,5'-PeCB 127 3,3',4,5,5'-Pentachlorobiphenyl EPA 1668A 39635-33-1 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 3,3',4,4',5-PeCB 126 3,3',4,4',5-Pentachlorobiphenyl EPA 1668A 57465-28-8 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 2,2',4,4',6,6'-HxCB 155 2,2',4,4',6,6'-Hexachlorobiphenyl EPA 1668A 33979-03-2 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 2,2',3,5,6,6'-HxCB 152 2,2',3,5,6,6'-Hexachlorobiphenyl EPA 1668A 68194-09-2 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 2,2',3,4',6,6'-HxCB 150 2,2',3,4',6,6'-Hexachlorobiphenyl EPA 1668A 68194-08-1 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 2,2',3,3',6,6'-HxCB 136 2,2',3,3',6,6'-Hexachlorobiphenyl EPA 1668A 38411-22-2 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 2,2',3,4,6,6'-HxCB 145 2,2',3,4,6,6'-Hexachlorobiphenyl EPA 1668A 74472-40-5 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 2,2',3,4',5,6'-HxCB 148 2,2',3,4',5,6'-Hexachlorobiphenyl EPA 1668A 74472-41-6 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE (135/151)135/151 NA (Co-elution)EPA 1668A mg/l ND 0.00000105 ND 0.00000107 ND 0.00000104 NE 2,2',4,4',5,6'-HxCB 154 2,2',4,4',5,6'-Hexachlorobiphenyl EPA 1668A 60145-22-4 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 2,2',3,4,5',6-HxCB 144 2,2',3,4,5',6-Hexachlorobiphenyl EPA 1668A 68194-14-9 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE (147/149)147/149 NA (Co-elution)EPA 1668A E52450814 mg/l ND 0.00000105 ND 0.00000104 NE (134/143)134/143 NA (Co-elution)EPA 1668A E52450780 mg/l ND 0.00000105 ND 0.00000107 ND 0.00000104 NE (139/140)139/140 NA (Co-elution)EPA 1668A E52450806 mg/l ND 0.00000105 ND 0.00000107 ND 0.00000104 NE 2,2',3,3',4,6-HxCB 131 2,2',3,3',4,6-Hexachlorobiphenyl EPA 1668A 61798-70-7 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 2,2',3,4,5,6-HxCB 142 2,2',3,4,5,6-Hexachlorobiphenyl EPA 1668A 41411-61-4 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 2,2',3,3',4,6'-HxCB 132 2,2',3,3',4,6'-Hexachlorobiphenyl EPA 1668A 38380-05-1 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 2,2',3,3',5,5'-HxCB 133 2,2',3,3',5,5'-Hexachlorobiphenyl EPA 1668A 35694-04-3 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 2,3,3',5,5',6-HxCB 165 2,3,3',5,5',6-Hexachlorobiphenyl EPA 1668A 74472-46-1 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 2,2',3,4',5,5'-HxCB 146 2,2',3,4',5,5'-Hexachlorobiphenyl EPA 1668A 51908-16-8 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 7/11/2018 7/11/2018 7/11/2018 13:25 12:50 12:20 Lower Ditch Middle Ditch Upper Ditch 0.000000588 0.00000167 0.00000106 0.000000776 0.00000225 0.00000146 0.000000761 0.000000603 0.00000117 0.000000864 0.00000119 0.000000639 0.00000139 0.00000108 0.00000059 0.000000655 0.0000014 0.00000104 Table 2-9 Eastern Drainage Ditch Surface Water Sample Analytical Results - Congener Analysis Alcoa/Badin Landfill Badin Business Park Facility Badin, North Carolina Sample ID Congener Number IUPAC Name Method CAS Units 15A NCAC 2B Surface Water StandardABL-SW013-F005ABL-SW014-F005ABL-SW015-F005Location Date Time 7/11/2018 7/11/2018 7/11/2018 13:25 12:50 12:20 Lower Ditch Middle Ditch Upper Ditch 2,3,3',4,5',6-HxCB 161 2,3,3',4,5',6-Hexachlorobiphenyl EPA 1668A 74472-43-8 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE (153/168)153/168 NA (Co-elution)EPA 1668A E52450822 mg/l ND 0.00000104 NE 2,2',3,4,5,5'-HxCB 141 2,2',3,4,5,5'-Hexachlorobiphenyl EPA 1668A 52712-04-6 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 2,2',3,3',4,5'-HxCB 130 2,2',3,3',4,5'-Hexachlorobiphenyl EPA 1668A 52663-66-8 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 2,2',3,4,4',5-HxCB 137 2,2',3,4,4',5-Hexachlorobiphenyl EPA 1668A 35694-06-5 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 2,3,3',4',5',6-HxCB 164 2,3,3',4',5',6-Hexachlorobiphenyl EPA 1668A 74472-45-0 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE (129/138/163)129/138/163 NA (Co-elution)EPA 1668A mg/l ND 0.00000157 ND 0.0000016 ND 0.00000155 NE 2,3,3',4,5,6-HxCB 160 2,3,3',4,5,6-Hexachlorobiphenyl EPA 1668A 41411-62-5 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 2,3,3',4,4',6-HxCB 158 2,3,3',4,4',6-Hexachlorobiphenyl EPA 1668A 74472-42-7 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE (128/166)128/166 NA (Co-elution)EPA 1668A E52450764 mg/l ND 0.00000105 ND 0.00000107 ND 0.00000104 NE 2,3,3',4,5,5'-HxCB 159 2,3,3',4,5,5'-Hexachlorobiphenyl EPA 1668A 39635-35-3 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 2,3,3',4',5,5'-HxCB 162 2,3,3',4',5,5'-Hexachlorobiphenyl EPA 1668A 39635-34-2 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 2,3',4,4',5,5'-HxCB 167 2,3',4,4',5,5'-Hexachlorobiphenyl EPA 1668A 52663-72-6 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE (156/157)156/157 NA (Co-elution)EPA 1668A E52450830 mg/l ND 0.00000105 ND 0.00000107 ND 0.00000104 NE 3,3',4,4',5,5'-HxCB 169 3,3',4,4',5,5'-Hexachlorobiphenyl EPA 1668A 32774-16-6 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 2,2',3,4',5,6,6'-HpCB 188 2,2',3,4',5,6,6'-Heptachlorobiphenyl EPA 1668A 74487-85-7 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 2,2',3,3',5,6,6'-HpCB 179 2,2',3,3',5,6,6'-Heptachlorobiphenyl EPA 1668A 52663-64-6 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 2,2',3,4,4',6,6'-HpCB 184 2,2',3,4,4',6,6'-Heptachlorobiphenyl EPA 1668A 74472-48-3 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 2,2',3,3',4,6,6'-HpCB 176 2,2',3,3',4,6,6'-Heptachlorobiphenyl EPA 1668A 52663-65-7 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 2,2',3,4,5,6,6'-HpCB 186 2,2',3,4,5,6,6'-Heptachlorobiphenyl EPA 1668A 74472-49-4 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 2,2',3,3',5,5',6-HpCB 178 2,2',3,3',5,5',6-Heptachlorobiphenyl EPA 1668A 52663-67-9 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 2,2',3,3',4,5',6-HpCB 175 2,2',3,3',4,5',6-Heptachlorobiphenyl EPA 1668A 40186-70-7 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 2,2',3,4',5,5',6-HpCB 187 2,2',3,4',5,5',6-Heptachlorobiphenyl EPA 1668A 52663-68-0 mg/l NE 2,2',3,4,4',5,6'-HpCB 182 2,2',3,4,4',5,6'-Heptachlorobiphenyl EPA 1668A 60145-23-5 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE (183/185)183/185 NA (Co-elution)EPA 1668A E52450863 mg/l ND 0.00000105 ND 0.00000107 ND 0.00000104 NE 2,2',3,3',4,5,6'-HpCB 174 2,2',3,3',4,5,6'-Heptachlorobiphenyl EPA 1668A 38411-25-5 mg/l ND 0.000000518 NE 2,2',3,3',4,5',6'-HpCB 177 2,2',3,3',4,5',6'-Heptachlorobiphenyl EPA 1668A 52663-70-4 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 2,2',3,4,4',5,6-HpCB 181 2,2',3,4,4',5,6-Heptachlorobiphenyl EPA 1668A 74472-47-2 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE (171/173)171/173 NA (Co-elution)EPA 1668A E52450848 mg/l ND 0.00000105 ND 0.00000107 ND 0.00000104 NE 2,2',3,3',4,5,5'-HpCB 172 2,2',3,3',4,5,5'-Heptachlorobiphenyl EPA 1668A 52663-74-8 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 2,3,3',4,5,5',6-HpCB 192 2,3,3',4,5,5',6-Heptachlorobiphenyl EPA 1668A 74472-51-8 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE (180/193)180/193 NA (Co-elution)EPA 1668A E52450855 mg/l ND 0.00000104 NE 2,3,3',4,4',5',6-HpCB 191 2,3,3',4,4',5',6-Heptachlorobiphenyl EPA 1668A 74472-50-7 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 2,2',3,3',4,4',5-HpCB 170 2,2',3,3',4,4',5-Heptachlorobiphenyl EPA 1668A 35065-30-6 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 2,3,3',4,4',5,6-HpCB 190 2,3,3',4,4',5,6-Heptachlorobiphenyl EPA 1668A 41411-64-7 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 2,3,3',4,4',5,5'-HpCB 189 2,3,3',4,4',5,5'-Heptachlorobiphenyl EPA 1668A 39635-31-9 mg/l ND 0.000000523 ND 0.000000535 ND 0.000000518 NE 2,2',3,3',5,5',6,6'-OcCB 202 2,2',3,3',5,5',6,6'-Octachlorobiphenyl EPA 1668A 2136-99-4 mg/l ND 0.000000784 ND 0.000000802 ND 0.000000777 NE 2,2',3,3',4,5',6,6'-OcCB 201 2,2',3,3',4,5',6,6'-Octachlorobiphenyl EPA 1668A 40186-71-8 mg/l ND 0.000000784 ND 0.000000802 ND 0.000000777 NE 2,2',3,4,4',5,6,6'-OcCB 204 2,2',3,4,4',5,6,6'-Octachlorobiphenyl EPA 1668A 74472-52-9 mg/l ND 0.000000784 ND 0.000000802 ND 0.000000777 NE (197/200)197/200 NA (Co-elution)EPA 1668A E52450871 mg/l ND 0.00000157 ND 0.0000016 ND 0.00000155 NE (198/199)198/199 NA (Co-elution)EPA 1668A E52450889 mg/l ND 0.00000157 ND 0.0000016 ND 0.00000155 NE 2,2',3,3',4,4',5,6'-OcCB 196 2,2',3,3',4,4',5,6'-Octachlorobiphenyl EPA 1668A 42740-50-1 mg/l ND 0.000000784 ND 0.000000802 ND 0.000000777 NE 2,2',3,4,4',5,5',6-OcCB 203 2,2',3,4,4',5,5',6-Octachlorobiphenyl EPA 1668A 52663-76-0 mg/l ND 0.000000784 ND 0.000000802 ND 0.000000777 NE 2,2',3,3',4,4',5,6-OcCB 195 2,2',3,3',4,4',5,6-Octachlorobiphenyl EPA 1668A 52663-78-2 mg/l ND 0.000000784 ND 0.000000802 ND 0.000000777 NE 2,2',3,3',4,4',5,5'-OcCB 194 2,2',3,3',4,4',5,5'-Octachlorobiphenyl EPA 1668A 35694-08-7 mg/l ND 0.000000784 ND 0.000000802 ND 0.000000777 NE 2,3,3',4,4',5,5',6-OcCB 205 2,3,3',4,4',5,5',6-Octachlorobiphenyl EPA 1668A 74472-53-0 mg/l ND 0.000000784 ND 0.000000802 ND 0.000000777 NE 2,2',3,3',4,5,5',6,6'-NoCB 208 2,2',3,3',4,5,5',6,6'-Nonachlorobiphenyl EPA 1668A 52663-77-1 mg/l ND 0.000000784 ND 0.000000802 ND 0.000000777 NE 2,2',3,3',4,4',5,6,6'-NoCB 207 2,2',3,3',4,4',5,6,6'-Nonachlorobiphenyl EPA 1668A 52663-79-3 mg/l ND 0.000000784 ND 0.000000802 ND 0.000000777 NE 2,2',3,3',4,4',5,5',6-NoCB 206 2,2',3,3',4,4',5,5',6-Nonachlorobiphenyl EPA 1668A 40186-72-9 mg/l ND 0.000000784 ND 0.000000802 ND 0.000000777 NE Decachlorobiphenyl 209 Decachlorobiphenyl EPA 1668A 2051-24-3 mg/l ND 0.000000784 ND 0.000000802 ND 0.000000777 NE Total Polychlorinated Biphenyls 1336-36-3 mg/l 0.000001 ND - The analyte was not detected above laboratory detection limits. Subscript indicates compound-specific Method Specified Reporting Limit (EML) in mg/kg. NE - Not established. 0.000000526 0.0000014 0.000000806 0.000015232 0.000010198 0.000002209 0.00000131 0.000000694 0.000000569 0.00000117 0.00000133 0.000000648 Table 2-10 Equipment Blank Analytical Results Alcoa/Badin Landfill Badin Business Park Facility Badin, North Carolina Sample ID Method CAS Units Location Date Time PCB-1016 (Aroclor 1016)EPA 8082 12674-11-2 mg/L ND 0.00042 PCB-1221 (Aroclor 1221)EPA 8082 11104-28-2 mg/L ND 0.00042 PCB-1232 (Aroclor 1232)EPA 8082 11141-16-5 mg/L ND 0.00042 PCB-1242 (Aroclor 1242)EPA 8082 53469-21-9 mg/L ND 0.00042 PCB-1248 (Aroclor 1248)EPA 8082 12672-29-6 mg/L ND 0.00042 PCB-1254 (Aroclor 1254)EPA 8082 11097-69-1 mg/L ND 0.00042 PCB-1260 (Aroclor 1260)EPA 8082 11096-82-5 mg/L ND 0.00042 Total Polychlorinated Biphenyls 1-Methylnaphthalene EPA 8270 90-12-0 mg/L ND 0.0020 2-Methylnaphthalene EPA 8270 91-57-6 mg/L ND 0.0020 Acenaphthene EPA 8270 83-32-9 mg/L ND 0.00050 Acenaphthylene EPA 8270 208-96-8 mg/L ND 0.00050 Anthracene EPA 8270 120-12-7 mg/L ND 0.000050 Benzo(a)anthracene EPA 8270 56-55-3 mg/L ND 0.000050 Benzo(a)pyrene EPA 8270 50-32-8 mg/L ND 0.00010 Benzo(b)fluoranthene EPA 8270 205-99-2 mg/L ND 0.000050 Benzo(g,h,i)perylene EPA 8270 191-24-2 mg/L ND 0.00020 Benzo(k)fluoranthene EPA 8270 207-08-9 mg/L ND 0.00020 Chrysene EPA 8270 218-01-9 mg/L ND 0.00010 Dibenz(a,h)anthracene EPA 8270 53-70-3 mg/L ND 0.00015 Fluoranthene EPA 8270 206-44-0 mg/L ND 0.00030 Fluorene EPA 8270 86-73-7 mg/L ND 0.00031 Indeno(1,2,3-cd)pyrene EPA 8270 193-39-5 mg/L ND 0.000050 Naphthalene EPA 8270 91-20-3 mg/L ND 0.0015 Phenanthrene EPA 8270 85-01-8 mg/L ND 0.00020 Pyrene EPA 8270 129-00-0 mg/L ND 0.00010 ND - The analyte was not detected above laboratory detection limits. Subscript indicates compound-specific MDL in mg/l.ABL-EB001-F005Equipment Blank 7/11/2018 14:10 ND Table 2-11 Equipment Blank Analytical Results - Congener Analysis Alcoa/Badin Landfill Badin Business Park Facility Badin, North Carolina Sample ID Congener Number IUPAC Name Method CAS Units Location Date Time 2-MoCB 1 2-Chlorobiphenyl EPA 1668A 2051-60-7 mg/l ND 0.00000025 3-MoCB 2 3-Chlorobiphenyl EPA 1668A 2051-61-8 mg/l ND 0.00000025 4-MoCB 3 4-Chlorobiphenyl EPA 1668A 2051-62-9 mg/l ND 0.00000025 2,2'-DiCB 4 2,2'-Dichlorobiphenyl EPA 1668A 13029-08-8 mg/l ND 0.00000025 2,6-DiCB 10 2,6-Dichlorobiphenyl EPA 1668A 33146-45-1 mg/l ND 0.00000025 2,5-DiCB 9 2,5-Dichlorobiphenyl EPA 1668A 34883-39-1 mg/l ND 0.00000025 2,4-DiCB 7 2,4-Dichlorobiphenyl EPA 1668A 33284-50-3 mg/l ND 0.00000025 2,3'-DiCB 6 2,3'-Dichlorobiphenyl EPA 1668A 25569-80-6 mg/l ND 0.00000025 2,3-DiCB 5 2,3-Dichlorobiphenyl EPA 1668A 16605-91-7 mg/l ND 0.00000025 2,4'-DiCB 8 2,4'-Dichlorobiphenyl EPA 1668A 34883-43-7 mg/l ND 0.00000025 3,5-DiCB 14 3,5-Dichlorobiphenyl EPA 1668A 34883-41-5 mg/l ND 0.00000025 3,3'-DiCB 11 3,3'-Dichlorobiphenyl EPA 1668A 2050-67-1 mg/l ND 0.00000245 (12/13)12/13 NA (Co-elution)EPA 1668A E52450566 mg/l ND 0.0000005 4,4'-DiCB 15 4,4'-Dichlorobiphenyl EPA 1668A 2050-68-2 mg/l ND 0.00000033 2,2',6-TrCB 19 2,2',6-Trichlorobiphenyl EPA 1668A 38444-73-4 mg/l ND 0.00000025 (18/30)18/30 NA (Co-elution)EPA 1668A E52450574 mg/l ND 0.0000005 2,2',4-TrCB 17 2,2',4-Trichlorobiphenyl EPA 1668A 37680-66-3 mg/l ND 0.00000025 2,3',6-TrCB 27 2,3',6-Trichlorobiphenyl EPA 1668A 38444-76-7 mg/l ND 0.00000025 2,3,6-TrCB 24 2,3,6-Trichlorobiphenyl EPA 1668A 55702-45-9 mg/l ND 0.00000025 2,2',3-TrCB 16 2,2',3-Trichlorobiphenyl EPA 1668A 38444-78-9 mg/l ND 0.00000025 2,4',6-TrCB 32 2,4',6-Trichlorobiphenyl EPA 1668A 38444-77-8 mg/l ND 0.00000025 2,3',5'-TrCB 34 2,3',5'-Trichlorobiphenyl EPA 1668A 37680-68-5 mg/l ND 0.00000025 2,3,5-TrCB 23 2,3,5-Trichlorobiphenyl EPA 1668A 55720-44-0 mg/l ND 0.00000025 (26/29)26/29 NA (Co-elution)EPA 1668A E52450608 mg/l ND 0.0000005 2,3',4-TrCB 25 2,3',4-Trichlorobiphenyl EPA 1668A 55712-37-3 mg/l ND 0.00000025 2,4',5-TrCB 31 2,4',5-Trichlorobiphenyl EPA 1668A 16606-02-3 mg/l ND 0.0000013 (20/28)20/28 NA (Co-elution)EPA 1668A E52450582 mg/l ND 0.00000129 (21/33)21/33 NA (Co-elution)EPA 1668A E52450590 mg/l ND 0.00000135 2,3,4'-TrCB 22 2,3,4'-Trichlorobiphenyl EPA 1668A 38444-85-8 mg/l ND 0.00000095 3,3',5-TrCB 36 3,3',5-Trichlorobiphenyl EPA 1668A 38444-87-0 mg/l ND 0.00000025 3,4',5-TrCB 39 3,4',5-Trichlorobiphenyl EPA 1668A 38444-88-1 mg/l ND 0.00000025 3,4,5-TrCB 38 3,4,5-Trichlorobiphenyl EPA 1668A 53555-66-1 mg/l ND 0.00000025 3,3',4-TrCB 35 3,3',4-Trichlorobiphenyl EPA 1668A 37680-69-6 mg/l ND 0.00000025 3,4,4'-TrCB 37 3,4,4'-Trichlorobiphenyl EPA 1668A 38444-90-5 mg/l ND 0.00000053 2,2',6,6'-TeCB 54 2,2',6,6'-Tetrachlorobiphenyl EPA 1668A 15968-05-5 mg/l ND 0.0000005 (50/53)50/53 NA (Co-elution)EPA 1668A E52450657 mg/l ND 0.000001 (45/51)45/51 NA (Co-elution)EPA 1668A E52450632 mg/l ND 0.000001 2,2',3,6'-TeCB 46 2,2',3,6'-Tetrachlorobiphenyl EPA 1668A 41464-47-5 mg/l ND 0.0000005 2,2',5,5'-TeCB 52 2,2',5,5'-Tetrachlorobiphenyl EPA 1668A 35693-99-3 mg/l ND 0.00000154 2,3',5',6-TeCB 73 2,3',5',6-Tetrachlorobiphenyl EPA 1668A 74338-23-1 mg/l ND 0.0000005 43/73 43/73 NA (Co-elution)EPA 1668A mg/l ND 0.0000005 (49/69)49/69 NA (Co-elution)EPA 1668A E52450640 mg/l ND 0.000001 2,2',4,5-TeCB 48 2,2',4,5-Tetrachlorobiphenyl EPA 1668A 70362-47-9 mg/l ND 0.0000005 (44/47/65)44/47/65 NA (Co-elution)EPA 1668A E52450624 mg/l ND 0.0000015 (59/62/75)59/62/75 NA (Co-elution)EPA 1668A E52450665 mg/l ND 0.0000015 2,2',3,4'-TeCB 42 2,2',3,4'-Tetrachlorobiphenyl EPA 1668A 36559-22-5 mg/l ND 0.0000005 (40/41/71)40/41/71 NA (Co-elution)EPA 1668A E52450616 mg/l ND 0.0000015 2,3,4',6-TeCB 64 2,3,4',6-Tetrachlorobiphenyl EPA 1668A 52663-58-8 mg/l ND 0.0000005 2,3',5,5'-TeCB 72 2,3',5,5'-Tetrachlorobiphenyl EPA 1668A 41464-42-0 mg/l ND 0.0000005 2,3',4,5'-TeCB 68 2,3',4,5'-Tetrachlorobiphenyl EPA 1668A 73575-52-7 mg/l ND 0.0000005 2,3,3',5-TeCB 57 2,3,3',5-Tetrachlorobiphenyl EPA 1668A 70424-67-8 mg/l ND 0.0000005 2,3,3',5'-TeCB 58 2,3,3',5'-Tetrachlorobiphenyl EPA 1668A 41464-49-7 mg/l ND 0.0000005 2,3',4,5-TeCB 67 2,3',4,5-Tetrachlorobiphenyl EPA 1668A 73575-53-8 mg/l ND 0.0000005 2,3,4',5-TeCB 63 2,3,4',5-Tetrachlorobiphenyl EPA 1668A 74472-34-7 mg/l ND 0.0000005 (61/70/74/76)60/70/74/76 NA (Co-elution)EPA 1668A E52450673 mg/l ND 0.000002 2,3',4,4'-TeCB 66 2,3',4,4'-Tetrachlorobiphenyl EPA 1668A 32598-10-0 mg/l ND 0.00000084 2,3,3',4-TeCB 55 2,3,3',4-Tetrachlorobiphenyl EPA 1668A 74338-24-2 mg/l ND 0.0000005 2,3,3',4'-TeCB 56 2,3,3',4'-Tetrachlorobiphenyl EPA 1668A 41464-43-1 mg/l ND 0.0000005 2,3,4,4'-TeCB 60 2,3,4,4'-Tetrachlorobiphenyl EPA 1668A 33025-41-1 mg/l ND 0.0000005 3,3',5,5'-TeCB 80 3,3',5,5'-Tetrachlorobiphenyl EPA 1668A 33284-52-5 mg/l ND 0.0000005 3,3',4,5'-TeCB 79 3,3',4,5'-Tetrachlorobiphenyl EPA 1668A 41464-48-6 mg/l ND 0.0000005 3,3',4,5-TeCB 78 3,3',4,5-Tetrachlorobiphenyl EPA 1668A 70362-49-1 mg/l ND 0.0000005 3,4,4',5-TeCB 81 3,4,4',5-Tetrachlorobiphenyl EPA 1668A 70362-50-4 mg/l ND 0.0000005 3,3',4,4'-TeCB 77 3,3',4,4'-Tetrachlorobiphenyl EPA 1668A 32598-13-3 mg/l ND 0.0000005 2,2',4,6,6'-PeCB 104 2,2',4,6,6'-Pentachlorobiphenyl EPA 1668A 56558-16-8 mg/l ND 0.0000005 2,2',3,6,6'-PeCB 96 2,2',3,6,6'-Pentachlorobiphenyl EPA 1668A 73575-54-9 mg/l ND 0.0000005 2,2',4,5',6-PeCB 103 2,2',4,5',6-Pentachlorobiphenyl EPA 1668A 60145-21-3 mg/l ND 0.0000005 2,2',3,5,6'-PeCB 94 2,2',3,5,6'-Pentachlorobiphenyl EPA 1668A 73575-55-0 mg/l ND 0.0000005 2,2',3,5',6-PeCB 95 2,2',3,5',6-Pentachlorobiphenyl EPA 1668A 38379-99-6 mg/l ND 0.00000095 (93/98/100/102)93/98/100/102 NA (Co-elution)EPA 1668A mg/l ND 0.000002 (88/91)88/91 NA (Co-elution)EPA 1668A E52450715 mg/l ND 0.000001 2,2',3,3',6-PeCB 84 2,2',3,3',6-Pentachlorobiphenyl EPA 1668A 52663-60-2 mg/l ND 0.0000005 2,2',3,4,6'-PeCB 89 2,2',3,4,6'-Pentachlorobiphenyl EPA 1668A 73575-57-2 mg/l ND 0.0000005 2,3',4,5',6-PeCB 121 2,3',4,5',6-Pentachlorobiphenyl EPA 1668A 56558-18-0 mg/l ND 0.0000005 2,2',3,5,5'-PeCB 92 2,2',3,5,5'-Pentachlorobiphenyl EPA 1668A 52663-61-3 mg/l ND 0.0000005 (90/101/113)90/101/113 NA (Co-elution)EPA 1668A E52450723 mg/l ND 0.0000015 2,2',3,3',5-PeCB 83 2,2',3,3',5-Pentachlorobiphenyl EPA 1668A 60145-20-2 mg/l ND 0.0000005 2,2',4,4',5-PeCB 99 2,2',4,4',5-Pentachlorobiphenyl EPA 1668A 38380-01-7 mg/l ND 0.0000005 2,3,3',5,6-PeCB 112 2,3,3',5,6-Pentachlorobiphenyl EPA 1668A 74472-36-9 mg/l ND 0.0000005 (86/87/97/108/119/125)86/87/97/108/119'125 NA (Co-elution)EPA 1668A E52450707 mg/l ND 0.000003 (85/117/116)85/117/116 NA (Co-elution)EPA 1668A E52450699 mg/l ND 0.0000015 (110/115)110/115 NA (Co-elution)EPA 1668A E52450756 mg/l ND 0.000001 2,2',3,3',4-PeCB 82 2,2',3,3',4-Pentachlorobiphenyl EPA 1668A 52663-62-4 mg/l ND 0.0000005 2,3,3',5,5'-PeCB 111 2,3,3',5,5'-Pentachlorobiphenyl EPA 1668A 39635-32-0 mg/l ND 0.0000005 2,3',4,5,5'-PeCB 120 2,3',4,5,5'-Pentachlorobiphenyl EPA 1668A 68194-12-7 mg/l ND 0.0000005 (107/124)107/124 NA (Co-elution)EPA 1668A E52450749 mg/l ND 0.000001 2,3,3',4,6-PeCB 109 2,3,3',4,6-Pentachlorobiphenyl EPA 1668A 74472-35-8 mg/l ND 0.0000005 2,3',4,4',5'-PeCB 123 2,3',4,4',5'-Pentachlorobiphenyl EPA 1668A 65510-44-3 mg/l ND 0.0000005 2,3,3',4,5-PeCB 106 2,3,3',4,5-Pentachlorobiphenyl EPA 1668A 70424-69-0 mg/l ND 0.0000005 2,3',4,4',5-PeCB 118 2,3',4,4',5-Pentachlorobiphenyl EPA 1668A 31508-00-6 mg/l ND 0.00000064 2,3,3',4',5'-PeCB 122 2,3,3',4',5'-Pentachlorobiphenyl EPA 1668A 76842-07-4 mg/l ND 0.0000005 2,3,4,4',5-PeCB 114 2,3,4,4',5-Pentachlorobiphenyl EPA 1668A 74472-37-0 mg/l ND 0.0000005 2,3,3',4,4'-PeCB 105 2,3,3',4,4'-Pentachlorobiphenyl EPA 1668A 32598-14-4 mg/l ND 0.0000005 7/11/2018 14:10 Equipment BlankABL-EB001-F005 Table 2-11 Equipment Blank Analytical Results - Congener Analysis Alcoa/Badin Landfill Badin Business Park Facility Badin, North Carolina Sample ID Congener Number IUPAC Name Method CAS Units Location Date Time 7/11/2018 14:10 Equipment BlankABL-EB001-F0053,3',4,5,5'-PeCB 127 3,3',4,5,5'-Pentachlorobiphenyl EPA 1668A 39635-33-1 mg/l ND 0.0000005 3,3',4,4',5-PeCB 126 3,3',4,4',5-Pentachlorobiphenyl EPA 1668A 57465-28-8 mg/l ND 0.0000005 2,2',4,4',6,6'-HxCB 155 2,2',4,4',6,6'-Hexachlorobiphenyl EPA 1668A 33979-03-2 mg/l ND 0.0000005 2,2',3,5,6,6'-HxCB 152 2,2',3,5,6,6'-Hexachlorobiphenyl EPA 1668A 68194-09-2 mg/l ND 0.0000005 2,2',3,4',6,6'-HxCB 150 2,2',3,4',6,6'-Hexachlorobiphenyl EPA 1668A 68194-08-1 mg/l ND 0.0000005 2,2',3,3',6,6'-HxCB 136 2,2',3,3',6,6'-Hexachlorobiphenyl EPA 1668A 38411-22-2 mg/l ND 0.0000005 2,2',3,4,6,6'-HxCB 145 2,2',3,4,6,6'-Hexachlorobiphenyl EPA 1668A 74472-40-5 mg/l ND 0.0000005 2,2',3,4',5,6'-HxCB 148 2,2',3,4',5,6'-Hexachlorobiphenyl EPA 1668A 74472-41-6 mg/l ND 0.0000005 (135/151)135/151 NA (Co-elution)EPA 1668A mg/l ND 0.000001 2,2',4,4',5,6'-HxCB 154 2,2',4,4',5,6'-Hexachlorobiphenyl EPA 1668A 60145-22-4 mg/l ND 0.0000005 2,2',3,4,5',6-HxCB 144 2,2',3,4,5',6-Hexachlorobiphenyl EPA 1668A 68194-14-9 mg/l ND 0.0000005 (147/149)147/149 NA (Co-elution)EPA 1668A E52450814 mg/l ND 0.000001 (134/143)134/143 NA (Co-elution)EPA 1668A E52450780 mg/l ND 0.000001 (139/140)139/140 NA (Co-elution)EPA 1668A E52450806 mg/l ND 0.000001 2,2',3,3',4,6-HxCB 131 2,2',3,3',4,6-Hexachlorobiphenyl EPA 1668A 61798-70-7 mg/l ND 0.0000005 2,2',3,4,5,6-HxCB 142 2,2',3,4,5,6-Hexachlorobiphenyl EPA 1668A 41411-61-4 mg/l ND 0.0000005 2,2',3,3',4,6'-HxCB 132 2,2',3,3',4,6'-Hexachlorobiphenyl EPA 1668A 38380-05-1 mg/l ND 0.0000005 2,2',3,3',5,5'-HxCB 133 2,2',3,3',5,5'-Hexachlorobiphenyl EPA 1668A 35694-04-3 mg/l ND 0.0000005 2,3,3',5,5',6-HxCB 165 2,3,3',5,5',6-Hexachlorobiphenyl EPA 1668A 74472-46-1 mg/l ND 0.0000005 2,2',3,4',5,5'-HxCB 146 2,2',3,4',5,5'-Hexachlorobiphenyl EPA 1668A 51908-16-8 mg/l ND 0.0000005 2,3,3',4,5',6-HxCB 161 2,3,3',4,5',6-Hexachlorobiphenyl EPA 1668A 74472-43-8 mg/l ND 0.0000005 (153/168)153/168 NA (Co-elution)EPA 1668A E52450822 mg/l ND 0.000001 2,2',3,4,5,5'-HxCB 141 2,2',3,4,5,5'-Hexachlorobiphenyl EPA 1668A 52712-04-6 mg/l ND 0.0000005 2,2',3,3',4,5'-HxCB 130 2,2',3,3',4,5'-Hexachlorobiphenyl EPA 1668A 52663-66-8 mg/l ND 0.0000005 2,2',3,4,4',5-HxCB 137 2,2',3,4,4',5-Hexachlorobiphenyl EPA 1668A 35694-06-5 mg/l ND 0.0000005 2,3,3',4',5',6-HxCB 164 2,3,3',4',5',6-Hexachlorobiphenyl EPA 1668A 74472-45-0 mg/l ND 0.0000005 (129/138/163)129/138/163 NA (Co-elution)EPA 1668A mg/l ND 0.0000015 2,3,3',4,5,6-HxCB 160 2,3,3',4,5,6-Hexachlorobiphenyl EPA 1668A 41411-62-5 mg/l ND 0.0000005 2,3,3',4,4',6-HxCB 158 2,3,3',4,4',6-Hexachlorobiphenyl EPA 1668A 74472-42-7 mg/l ND 0.0000005 (128/166)128/166 NA (Co-elution)EPA 1668A E52450764 mg/l ND 0.000001 2,3,3',4,5,5'-HxCB 159 2,3,3',4,5,5'-Hexachlorobiphenyl EPA 1668A 39635-35-3 mg/l ND 0.0000005 2,3,3',4',5,5'-HxCB 162 2,3,3',4',5,5'-Hexachlorobiphenyl EPA 1668A 39635-34-2 mg/l ND 0.0000005 2,3',4,4',5,5'-HxCB 167 2,3',4,4',5,5'-Hexachlorobiphenyl EPA 1668A 52663-72-6 mg/l ND 0.0000005 (156/157)156/157 NA (Co-elution)EPA 1668A E52450830 mg/l ND 0.000001 3,3',4,4',5,5'-HxCB 169 3,3',4,4',5,5'-Hexachlorobiphenyl EPA 1668A 32774-16-6 mg/l ND 0.0000005 2,2',3,4',5,6,6'-HpCB 188 2,2',3,4',5,6,6'-Heptachlorobiphenyl EPA 1668A 74487-85-7 mg/l ND 0.0000005 2,2',3,3',5,6,6'-HpCB 179 2,2',3,3',5,6,6'-Heptachlorobiphenyl EPA 1668A 52663-64-6 mg/l ND 0.0000005 2,2',3,4,4',6,6'-HpCB 184 2,2',3,4,4',6,6'-Heptachlorobiphenyl EPA 1668A 74472-48-3 mg/l ND 0.0000005 2,2',3,3',4,6,6'-HpCB 176 2,2',3,3',4,6,6'-Heptachlorobiphenyl EPA 1668A 52663-65-7 mg/l ND 0.0000005 2,2',3,4,5,6,6'-HpCB 186 2,2',3,4,5,6,6'-Heptachlorobiphenyl EPA 1668A 74472-49-4 mg/l ND 0.0000005 2,2',3,3',5,5',6-HpCB 178 2,2',3,3',5,5',6-Heptachlorobiphenyl EPA 1668A 52663-67-9 mg/l ND 0.0000005 2,2',3,3',4,5',6-HpCB 175 2,2',3,3',4,5',6-Heptachlorobiphenyl EPA 1668A 40186-70-7 mg/l ND 0.0000005 2,2',3,4',5,5',6-HpCB 187 2,2',3,4',5,5',6-Heptachlorobiphenyl EPA 1668A 52663-68-0 mg/l ND 0.0000005 2,2',3,4,4',5,6'-HpCB 182 2,2',3,4,4',5,6'-Heptachlorobiphenyl EPA 1668A 60145-23-5 mg/l ND 0.0000005 (183/185)183/185 NA (Co-elution)EPA 1668A E52450863 mg/l ND 0.000001 2,2',3,3',4,5,6'-HpCB 174 2,2',3,3',4,5,6'-Heptachlorobiphenyl EPA 1668A 38411-25-5 mg/l ND 0.0000005 2,2',3,3',4,5',6'-HpCB 177 2,2',3,3',4,5',6'-Heptachlorobiphenyl EPA 1668A 52663-70-4 mg/l ND 0.0000005 2,2',3,4,4',5,6-HpCB 181 2,2',3,4,4',5,6-Heptachlorobiphenyl EPA 1668A 74472-47-2 mg/l ND 0.0000005 (171/173)171/173 NA (Co-elution)EPA 1668A E52450848 mg/l ND 0.000001 2,2',3,3',4,5,5'-HpCB 172 2,2',3,3',4,5,5'-Heptachlorobiphenyl EPA 1668A 52663-74-8 mg/l ND 0.0000005 2,3,3',4,5,5',6-HpCB 192 2,3,3',4,5,5',6-Heptachlorobiphenyl EPA 1668A 74472-51-8 mg/l ND 0.0000005 (180/193)180/193 NA (Co-elution)EPA 1668A E52450855 mg/l ND 0.000001 2,3,3',4,4',5',6-HpCB 191 2,3,3',4,4',5',6-Heptachlorobiphenyl EPA 1668A 74472-50-7 mg/l ND 0.0000005 2,2',3,3',4,4',5-HpCB 170 2,2',3,3',4,4',5-Heptachlorobiphenyl EPA 1668A 35065-30-6 mg/l ND 0.0000005 2,3,3',4,4',5,6-HpCB 190 2,3,3',4,4',5,6-Heptachlorobiphenyl EPA 1668A 41411-64-7 mg/l ND 0.0000005 2,3,3',4,4',5,5'-HpCB 189 2,3,3',4,4',5,5'-Heptachlorobiphenyl EPA 1668A 39635-31-9 mg/l ND 0.0000005 2,2',3,3',5,5',6,6'-OcCB 202 2,2',3,3',5,5',6,6'-Octachlorobiphenyl EPA 1668A 2136-99-4 mg/l ND 0.00000075 2,2',3,3',4,5',6,6'-OcCB 201 2,2',3,3',4,5',6,6'-Octachlorobiphenyl EPA 1668A 40186-71-8 mg/l ND 0.00000075 2,2',3,4,4',5,6,6'-OcCB 204 2,2',3,4,4',5,6,6'-Octachlorobiphenyl EPA 1668A 74472-52-9 mg/l ND 0.00000075 (197/200)197/200 NA (Co-elution)EPA 1668A E52450871 mg/l ND 0.0000015 (198/199)198/199 NA (Co-elution)EPA 1668A E52450889 mg/l ND 0.0000015 2,2',3,3',4,4',5,6'-OcCB 196 2,2',3,3',4,4',5,6'-Octachlorobiphenyl EPA 1668A 42740-50-1 mg/l ND 0.00000075 2,2',3,4,4',5,5',6-OcCB 203 2,2',3,4,4',5,5',6-Octachlorobiphenyl EPA 1668A 52663-76-0 mg/l ND 0.00000075 2,2',3,3',4,4',5,6-OcCB 195 2,2',3,3',4,4',5,6-Octachlorobiphenyl EPA 1668A 52663-78-2 mg/l ND 0.00000075 2,2',3,3',4,4',5,5'-OcCB 194 2,2',3,3',4,4',5,5'-Octachlorobiphenyl EPA 1668A 35694-08-7 mg/l ND 0.00000075 2,3,3',4,4',5,5',6-OcCB 205 2,3,3',4,4',5,5',6-Octachlorobiphenyl EPA 1668A 74472-53-0 mg/l ND 0.00000075 2,2',3,3',4,5,5',6,6'-NoCB 208 2,2',3,3',4,5,5',6,6'-Nonachlorobiphenyl EPA 1668A 52663-77-1 mg/l ND 0.00000075 2,2',3,3',4,4',5,6,6'-NoCB 207 2,2',3,3',4,4',5,6,6'-Nonachlorobiphenyl EPA 1668A 52663-79-3 mg/l ND 0.00000075 2,2',3,3',4,4',5,5',6-NoCB 206 2,2',3,3',4,4',5,5',6-Nonachlorobiphenyl EPA 1668A 40186-72-9 mg/l ND 0.00000075 Decachlorobiphenyl 209 Decachlorobiphenyl EPA 1668A 2051-24-3 mg/l ND 0.00000075 Total Polychlorinated Biphenyls 1336-36-3 mg/l ND - The analyte was not detected above laboratory detection limits. Subscript indicates compound-specific Method Specified Reporting Limit (EML) in mg/l. ND Table 2-12 Trip Blank Analytical Results Alcoa/Badin Municipal Landfill Badin Business Park Facility Badin, North Carolina Sample ID Method CAS Units ABL-TB001-F005Location Date 1,1,1-Trichloroethane EPA 624 71-55-6 mg/l ND 0.0019 1,1,2,2-Tetrachloroethane EPA 624 79-34-5 mg/l ND 0.0015 1,1,2-Trichloroethane EPA 624 79-00-5 mg/l ND 0.0017 1,1-Dichloroethane EPA 624 75-34-3 mg/l ND 0.0018 1,1-Dichloroethene EPA 624 75-35-4 mg/l ND 0.0019 1,2,4-Trichlorobenzene EPA 624 120-82-1 mg/l ND 0.0017 1,2-Dichlorobenzene EPA 624 95-50-1 mg/l ND 0.0015 1,2-Dichloroethane EPA 624 107-06-2 mg/l ND 0.0018 1,2-Dichloropropane EPA 624 78-87-5 mg/l ND 0.0017 1,3-Dichlorobenzene EPA 624 541-73-1 mg/l ND 0.0015 1,4-Dichlorobenzene EPA 624 106-46-7 mg/l ND 0.0015 2-Chloroethylvinyl ether EPA 624 110-75-8 mg/l ND 0.0022 Acrolein EPA 624 107-02-8 mg/l ND 0.0010 Acrylonitrile EPA 624 107-13-1 mg/l ND 0.0115 Benzene EPA 624 71-43-2 mg/l ND 0.0017 Bromodichloromethane EPA 624 75-27-4 mg/l ND 0.0017 Bromoform EPA 624 75-25-2 mg/l ND 0.0015 Bromomethane EPA 624 74-83-9 mg/l ND 0.0010 Carbon tetrachloride EPA 624 56-23-5 mg/l ND 0.0019 Chlorobenzene EPA 624 108-90-7 mg/l ND 0.0017 Chloroethane EPA 624 75-00-3 mg/l ND 0.0016 Chloroform EPA 624 67-66-3 mg/l ND 0.0019 Chloromethane EPA 624 74-87-3 mg/l ND 0.0015 cis-1,3-Dichloropropene EPA 624 10061-01-5 mg/l ND 0.0016 Dibromochloromethane EPA 624 124-48-1 mg/l ND 0.0018 Ethylbenzene EPA 624 100-41-4 mg/l ND 0.0016 Methylene Chloride EPA 624 75-09-2 mg/l ND 0.0019 Tetrachloroethene EPA 624 127-18-4 mg/l ND 0.0018 Toluene EPA 624 108-88-3 mg/l ND 0.0016 trans-1,2-Dichloroethene EPA 624 156-60-5 mg/l ND 0.0018 trans-1,3-Dichloropropene EPA 624 10061-02-6 mg/l ND 0.0016 Trichloroethene EPA 624 79-01-6 mg/l ND 0.0018 Trichlorofluoromethane EPA 624 75-69-4 mg/l ND 0.0017 Vinyl chloride EPA 624 75-01-4 mg/l ND 0.0015 ND - The analyte was not detected above laboratory detection limits. Subscript indicates compound-specific MDL in mg/l. Trip Blank 7/12/2018 ENVIRONEERING, INC. 137-263 Little Mountain Creek Area Report – Badin Business Park Facility - Badin, NC; December 2018 27 3.0 CONCLUSIONS Results from the field activities developed to meet objectives outlined under Subtask 1, Surface Water Assessment as defined in the April 2, 2018 revised Work Plan are detailed below. Objective - Determine the contribution of cyanide and fluoride compounds from the Eastern Drainage Ditch to Little Mountain Creek:  Neither cyanide or fluoride were detected in excess of regulatory standards in Little Mountain Creek surface water samples. While cyanide concentrations were reported below laboratory detection limits, fluoride concentrations were reported as estimated results and varied little from upstream to downstream.  Both fluoride and cyanide were detected above regulatory levels in surface water samples collected from the upper and middle sections of the Eastern Drainage Ditch; however, fluoride was reported below the regulatory standard in the surface water samples collected from the lower section of Eastern Drainage Ditch. Concentrations of fluoride were greatest near the landfill; whereas, cyanide concentrations increased nearer to Little Mountain Creek. Objective - Examine the potential source of the PCBs and PAHs in and adjacent to the Eastern Drainage Ditch:  Concentrations of PAHs above regulatory levels were detected in one sediment sample collected from the middle section of the Eastern Drainage Ditch. Sediment samples from the upper and lower sections of the Eastern Drainage Ditch did not contain concentrations of PAHs above regulatory levels, indicating the extent of PAHs in sediments is limited. No surface water sample from the Eastern Drainage Ditch contained a detection of PAHs above laboratory detection limits.  The sum of PCB congener concentrations in sediment samples collected from the middle and lower sections of the Eastern Drainage Ditch were greater than the respective screening level. The sediment sample collected from the upper section contained a sum of PCB congener concentrations lower than screening level suggesting the extent of elevated PCB congeners in sediments is limited to the middle and lower sections of the Eastern Drainage Ditch. Similarly, the total PCB congeners in surface water was observed to increase in concentration between the Alcoa/Badin Landfill and Little Mountain Creek. Objective - Assess the variation on constituent levels in Little Mountain Creek as intended by the instream monitoring study requirements of the September 29, 2017 Final NPDES Permit Renewal, Condition A. (8.).  No constituents were detected above regulatory levels in any of the sediment samples collected from Little Mountain Creek.  The sum of PCB congener concentrations was reported above regulatory levels in one of the surface water samples collected from Little Mountain Creek. However, the sum of the congener ENVIRONEERING, INC. 137-263 Little Mountain Creek Area Report – Badin Business Park Facility - Badin, NC; December 2018 28 concentrations in the duplicate sample collected at the same time and same location were below laboratory detection limits.  The 40 Code of Federal Regulations (CFR) 423 Appendix A (Priority Pollutant) analysis of surface water samples from Little Mountain Creek indicated concentrations of PAHs above regulatory limits; however, no surface water sample from the Eastern Drainage Ditch contained a detection of PAHs above laboratory detection limits. The sample location containing the detection was east of NC Highway 740 which has the potential to be influenced from offsite sources to include distressed asphalt, an operating electrical substation, and a county-operating satellite waste collection and recycling facility. Results from the Subtasks 2 through 4 will be submitted after completion of each respective subtask scope of work. ENVIRONEERING, INC. Appendix A Laboratory Reports and Chain of Custody Forms #=CL# July 30, 2018 LIMS USE: FR - MICHAEL WORDEN LIMS OBJECT ID: 92391723 92391723 Project: Pace Project No.: RE: Michael W. Worden Environeering, Inc. 16100 Cairnway Suite 320 Houston, TX 77084 Little Mountain Creek Sediment Dear Michael Worden: Enclosed are the analytical results for sample(s) received by the laboratory on July 12, 2018. The results relate only to the samples included in this report. Results reported herein conform to the most current, applicable TNI/NELAC standards and the laboratory's Quality Assurance Manual, where applicable, unless otherwise noted in the body of the report. If you have any questions concerning this report, please feel free to contact me. Sincerely, Nicole Gasiorowski nicole.gasiorowski@pacelabs.com Project Manager (704)875-9092 Enclosures REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 1 of 58 #=CP# CERTIFICATIONS Pace Project No.: Project: 92391723 Little Mountain Creek Sediment Charlotte Certification IDs 9800 Kincey Ave. Ste 100, Huntersville, NC 28078 Louisiana/NELAP Certification # LA170028 North Carolina Drinking Water Certification #: 37706 North Carolina Field Services Certification #: 5342 North Carolina Wastewater Certification #: 12 South Carolina Certification #: 99006001 Florida/NELAP Certification #: E87627 Kentucky UST Certification #: 84 Virginia/VELAP Certification #: 460221 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 2 of 58 #=SS# SAMPLE SUMMARY Pace Project No.: Project: 92391723 Little Mountain Creek Sediment Lab ID Sample ID Matrix Date Collected Date Received 92391723001 ABL-SD007-F005 Solid 07/12/18 08:35 07/12/18 12:30 92391723002 ABL-SD007-D005 Solid 07/12/18 08:40 07/12/18 12:30 92391723003 ABL-SD008-F005 Solid 07/12/18 10:10 07/12/18 12:30 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 3 of 58 #=SA# SAMPLE ANALYTE COUNT Pace Project No.: Project: 92391723 Little Mountain Creek Sediment Lab ID Sample ID Method Analytes Reported LaboratoryAnalysts 92391723001 ABL-SD007-F005 EPA 8082A 8 PASI-CNU1 EPA 8270D by SIM 21 PASI-CPKS ASTM D2974-87 1 PASI-CKDF 92391723002 ABL-SD007-D005 EPA 8082A 8 PASI-CNU1 EPA 8270D by SIM 21 PASI-CPKS ASTM D2974-87 1 PASI-CKDF 92391723003 ABL-SD008-F005 EPA 8082A 8 PASI-CNU1 EPA 8270D by SIM 21 PASI-CPKS ASTM D2974-87 1 PASI-CKDF REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 4 of 58 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92391723 Little Mountain Creek Sediment Sample:ABL-SD007-F005 Lab ID:92391723001 Collected:07/12/18 08:35 Received:07/12/18 12:30 Matrix:Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 8082A Preparation Method: EPA 35468082 GCS PCB PCB-1016 (Aroclor 1016)ND ug/kg 07/13/18 17:58 12674-11-207/12/18 18:1737.8 17.2 1 PCB-1221 (Aroclor 1221)ND ug/kg 07/13/18 17:58 11104-28-207/12/18 18:1737.8 17.2 1 PCB-1232 (Aroclor 1232)ND ug/kg 07/13/18 17:58 11141-16-507/12/18 18:1737.8 17.2 1 PCB-1242 (Aroclor 1242)ND ug/kg 07/13/18 17:58 53469-21-907/12/18 18:1737.8 17.2 1 PCB-1248 (Aroclor 1248)ND ug/kg 07/13/18 17:58 12672-29-607/12/18 18:1737.8 17.2 1 PCB-1254 (Aroclor 1254)ND ug/kg 07/13/18 17:58 11097-69-107/12/18 18:1737.8 17.2 1 PCB-1260 (Aroclor 1260)ND ug/kg 07/13/18 17:58 11096-82-507/12/18 18:1737.8 17.2 1 Surrogates Decachlorobiphenyl (S)60 %07/13/18 17:58 2051-24-307/12/18 18:1721-132 1 Analytical Method: EPA 8270D by SIM Preparation Method: EPA 35468270 MSSV MW PAH by SIM Acenaphthene ND ug/kg 07/17/18 14:53 83-32-907/12/18 18:1611.3 1.7 1 Acenaphthylene ND ug/kg 07/17/18 14:53 208-96-807/12/18 18:1611.3 1.5 1 Anthracene ND ug/kg 07/17/18 14:53 120-12-707/12/18 18:1611.3 1.6 1 Benzo(a)anthracene ND ug/kg 07/17/18 14:53 56-55-307/12/18 18:1611.3 0.80 1 Benzo(a)pyrene ND ug/kg 07/17/18 14:53 50-32-807/12/18 18:1611.3 1.2 1 Benzo(b)fluoranthene ND ug/kg 07/17/18 14:53 205-99-207/12/18 18:1611.3 0.76 1 Benzo(g,h,i)perylene ND ug/kg 07/17/18 14:53 191-24-207/12/18 18:1611.3 2.9 1 Benzo(k)fluoranthene ND ug/kg 07/17/18 14:53 207-08-907/12/18 18:1611.3 1.7 1 Chrysene ND ug/kg 07/17/18 14:53 218-01-907/12/18 18:1611.3 2.0 1 Dibenz(a,h)anthracene ND ug/kg 07/17/18 14:53 53-70-307/12/18 18:1611.3 2.0 1 Fluoranthene ND ug/kg 07/17/18 14:53 206-44-007/12/18 18:1611.3 0.94 1 Fluorene ND ug/kg 07/17/18 14:53 86-73-707/12/18 18:1611.3 1.8 1 Indeno(1,2,3-cd)pyrene ND ug/kg 07/17/18 14:53 193-39-507/12/18 18:1611.3 3.2 1 1-Methylnaphthalene ND ug/kg 07/17/18 14:53 90-12-007/12/18 18:1611.3 1.4 1 2-Methylnaphthalene ND ug/kg 07/17/18 14:53 91-57-607/12/18 18:1611.3 1.2 1 Naphthalene ND ug/kg 07/17/18 14:53 91-20-307/12/18 18:1611.3 2.6 1 Phenanthrene ND ug/kg 07/17/18 14:53 85-01-807/12/18 18:1611.3 1.7 1 Pyrene ND ug/kg 07/17/18 14:53 129-00-007/12/18 18:1611.3 2.0 1 Surrogates Nitrobenzene-d5 (S)45 %07/17/18 14:53 4165-60-007/12/18 18:1610-128 1 2-Fluorobiphenyl (S)36 %07/17/18 14:53 321-60-807/12/18 18:1610-110 1 Terphenyl-d14 (S)44 %07/17/18 14:53 1718-51-007/12/18 18:1639-119 1 Analytical Method: ASTM D2974-87Percent Moisture Percent Moisture 11.2 %07/13/18 11:570.10 0.10 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 07/30/2018 01:01 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 5 of 58 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92391723 Little Mountain Creek Sediment Sample:ABL-SD007-D005 Lab ID:92391723002 Collected:07/12/18 08:40 Received:07/12/18 12:30 Matrix:Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 8082A Preparation Method: EPA 35468082 GCS PCB PCB-1016 (Aroclor 1016)ND ug/kg 07/13/18 18:19 12674-11-207/12/18 18:1736.7 16.7 1 PCB-1221 (Aroclor 1221)ND ug/kg 07/13/18 18:19 11104-28-207/12/18 18:1736.7 16.7 1 PCB-1232 (Aroclor 1232)ND ug/kg 07/13/18 18:19 11141-16-507/12/18 18:1736.7 16.7 1 PCB-1242 (Aroclor 1242)ND ug/kg 07/13/18 18:19 53469-21-907/12/18 18:1736.7 16.7 1 PCB-1248 (Aroclor 1248)ND ug/kg 07/13/18 18:19 12672-29-607/12/18 18:1736.7 16.7 1 PCB-1254 (Aroclor 1254)ND ug/kg 07/13/18 18:19 11097-69-107/12/18 18:1736.7 16.7 1 PCB-1260 (Aroclor 1260)ND ug/kg 07/13/18 18:19 11096-82-507/12/18 18:1736.7 16.7 1 Surrogates Decachlorobiphenyl (S)48 %07/13/18 18:19 2051-24-307/12/18 18:1721-132 1 Analytical Method: EPA 8270D by SIM Preparation Method: EPA 35468270 MSSV MW PAH by SIM Acenaphthene 2.8J ug/kg 07/17/18 15:17 83-32-907/12/18 18:1611.0 1.7 1 Acenaphthylene ND ug/kg 07/17/18 15:17 208-96-807/12/18 18:1611.0 1.4 1 Anthracene 6.0J ug/kg 07/17/18 15:17 120-12-707/12/18 18:1611.0 1.5 1 Benzo(a)anthracene 28.0 ug/kg 07/17/18 15:17 56-55-307/12/18 18:1611.0 0.78 1 Benzo(a)pyrene 32.2 ug/kg 07/17/18 15:17 50-32-807/12/18 18:1611.0 1.2 1 Benzo(b)fluoranthene 42.2 ug/kg 07/17/18 15:17 205-99-207/12/18 18:1611.0 0.74 1 Benzo(g,h,i)perylene 16.1 ug/kg 07/17/18 15:17 191-24-207/12/18 18:1611.0 2.9 1 Benzo(k)fluoranthene 14.9 ug/kg 07/17/18 15:17 207-08-907/12/18 18:1611.0 1.7 1 Chrysene 27.6 ug/kg 07/17/18 15:17 218-01-907/12/18 18:1611.0 2.0 1 Dibenz(a,h)anthracene 4.7J ug/kg 07/17/18 15:17 53-70-307/12/18 18:1611.0 2.0 1 Fluoranthene 43.3 ug/kg 07/17/18 15:17 206-44-007/12/18 18:1611.0 0.92 1 Fluorene 2.1J ug/kg 07/17/18 15:17 86-73-707/12/18 18:1611.0 1.8 1 Indeno(1,2,3-cd)pyrene 14.8 ug/kg 07/17/18 15:17 193-39-507/12/18 18:1611.0 3.1 1 1-Methylnaphthalene ND ug/kg 07/17/18 15:17 90-12-007/12/18 18:1611.0 1.3 1 2-Methylnaphthalene ND ug/kg 07/17/18 15:17 91-57-607/12/18 18:1611.0 1.2 1 Naphthalene ND ug/kg 07/17/18 15:17 91-20-307/12/18 18:1611.0 2.5 1 Phenanthrene 24.1 ug/kg 07/17/18 15:17 85-01-807/12/18 18:1611.0 1.7 1 Pyrene 37.8 ug/kg 07/17/18 15:17 129-00-007/12/18 18:1611.0 2.0 1 Surrogates Nitrobenzene-d5 (S)42 %07/17/18 15:17 4165-60-007/12/18 18:1610-128 1 2-Fluorobiphenyl (S)31 %07/17/18 15:17 321-60-807/12/18 18:1610-110 1 Terphenyl-d14 (S)34 %07/17/18 15:17 1718-51-0 S007/12/18 18:1639-119 1 Analytical Method: ASTM D2974-87Percent Moisture Percent Moisture 9.1 %07/13/18 11:570.10 0.10 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 07/30/2018 01:01 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 6 of 58 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92391723 Little Mountain Creek Sediment Sample:ABL-SD008-F005 Lab ID:92391723003 Collected:07/12/18 10:10 Received:07/12/18 12:30 Matrix:Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 8082A Preparation Method: EPA 35468082 GCS PCB PCB-1016 (Aroclor 1016)ND ug/kg 07/13/18 18:40 12674-11-207/12/18 18:1742.1 19.1 1 PCB-1221 (Aroclor 1221)ND ug/kg 07/13/18 18:40 11104-28-207/12/18 18:1742.1 19.1 1 PCB-1232 (Aroclor 1232)ND ug/kg 07/13/18 18:40 11141-16-507/12/18 18:1742.1 19.1 1 PCB-1242 (Aroclor 1242)ND ug/kg 07/13/18 18:40 53469-21-907/12/18 18:1742.1 19.1 1 PCB-1248 (Aroclor 1248)ND ug/kg 07/13/18 18:40 12672-29-607/12/18 18:1742.1 19.1 1 PCB-1254 (Aroclor 1254)ND ug/kg 07/13/18 18:40 11097-69-107/12/18 18:1742.1 19.1 1 PCB-1260 (Aroclor 1260)ND ug/kg 07/13/18 18:40 11096-82-507/12/18 18:1742.1 19.1 1 Surrogates Decachlorobiphenyl (S)38 %07/13/18 18:40 2051-24-307/12/18 18:1721-132 1 Analytical Method: EPA 8270D by SIM Preparation Method: EPA 35468270 MSSV MW PAH by SIM Acenaphthene ND ug/kg 07/17/18 17:36 83-32-907/12/18 18:1613.1 2.0 1 Acenaphthylene ND ug/kg 07/17/18 17:36 208-96-807/12/18 18:1613.1 1.7 1 Anthracene ND ug/kg 07/17/18 17:36 120-12-7 IO07/12/18 18:1613.1 1.8 1 Benzo(a)anthracene ND ug/kg 07/17/18 17:36 56-55-307/12/18 18:1613.1 0.93 1 Benzo(a)pyrene ND ug/kg 07/17/18 17:36 50-32-8 IO07/12/18 18:1613.1 1.4 1 Benzo(b)fluoranthene ND ug/kg 07/17/18 17:36 205-99-207/12/18 18:1613.1 0.88 1 Benzo(g,h,i)perylene ND ug/kg 07/17/18 17:36 191-24-2 IO07/12/18 18:1613.1 3.4 1 Benzo(k)fluoranthene ND ug/kg 07/17/18 17:36 207-08-907/12/18 18:1613.1 2.0 1 Chrysene ND ug/kg 07/17/18 17:36 218-01-907/12/18 18:1613.1 2.4 1 Dibenz(a,h)anthracene ND ug/kg 07/17/18 17:36 53-70-3 IO07/12/18 18:1613.1 2.4 1 Fluoranthene ND ug/kg 07/17/18 17:36 206-44-0 IO07/12/18 18:1613.1 1.1 1 Fluorene ND ug/kg 07/17/18 17:36 86-73-707/12/18 18:1613.1 2.1 1 Indeno(1,2,3-cd)pyrene ND ug/kg 07/17/18 17:36 193-39-5 IO07/12/18 18:1613.1 3.7 1 1-Methylnaphthalene ND ug/kg 07/17/18 17:36 90-12-007/12/18 18:1613.1 1.6 1 2-Methylnaphthalene ND ug/kg 07/17/18 17:36 91-57-607/12/18 18:1613.1 1.4 1 Naphthalene ND ug/kg 07/17/18 17:36 91-20-307/12/18 18:1613.1 3.0 1 Phenanthrene ND ug/kg 07/17/18 17:36 85-01-8 IO07/12/18 18:1613.1 2.0 1 Pyrene ND ug/kg 07/17/18 17:36 129-00-0 IO07/12/18 18:1613.1 2.4 1 Surrogates Nitrobenzene-d5 (S)46 %07/17/18 17:36 4165-60-007/12/18 18:1610-128 1 2-Fluorobiphenyl (S)36 %07/17/18 17:36 321-60-807/12/18 18:1610-110 1 Terphenyl-d14 (S)39 %07/17/18 17:36 1718-51-007/12/18 18:1639-119 1 Analytical Method: ASTM D2974-87Percent Moisture Percent Moisture 22.6 %07/13/18 11:570.10 0.10 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 07/30/2018 01:01 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 7 of 58 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92391723 Little Mountain Creek Sediment Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 418842 EPA 3546 EPA 8082A 8082 GCS PCB Associated Lab Samples:92391723001, 92391723002, 92391723003 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:2321763 Associated Lab Samples:92391723001, 92391723002, 92391723003 Matrix:Solid AnalyzedMDL PCB-1016 (Aroclor 1016)ug/kg ND 32.8 07/13/18 13:4314.9 PCB-1221 (Aroclor 1221)ug/kg ND 32.8 07/13/18 13:4314.9 PCB-1232 (Aroclor 1232)ug/kg ND 32.8 07/13/18 13:4314.9 PCB-1242 (Aroclor 1242)ug/kg ND 32.8 07/13/18 13:4314.9 PCB-1248 (Aroclor 1248)ug/kg ND 32.8 07/13/18 13:4314.9 PCB-1254 (Aroclor 1254)ug/kg ND 32.8 07/13/18 13:4314.9 PCB-1260 (Aroclor 1260)ug/kg ND 32.8 07/13/18 13:4314.9 Decachlorobiphenyl (S)%95 21-132 07/13/18 13:43 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 2321764LABORATORY CONTROL SAMPLE & LCSD: LCSSpike LCSD % Rec RPD Max RPD LCSD Result 2321765 PCB-1016 (Aroclor 1016)ug/kg 131167 79 31-12088147 11 30 PCB-1260 (Aroclor 1260)ug/kg 148167 89 32-120102170 14 30 Decachlorobiphenyl (S)%102 21-132113 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 07/30/2018 01:01 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 8 of 58 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92391723 Little Mountain Creek Sediment Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 418920 EPA 3546 EPA 8270D by SIM 8270 MSSV PAH by SIM Associated Lab Samples:92391723001, 92391723002, 92391723003 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:2322225 Associated Lab Samples:92391723001, 92391723002, 92391723003 Matrix:Solid AnalyzedMDL 1-Methylnaphthalene ug/kg ND 9.9 07/17/18 10:361.2 2-Methylnaphthalene ug/kg 1.7J 9.9 07/17/18 10:361.1 Acenaphthene ug/kg ND 9.9 07/17/18 10:361.5 Acenaphthylene ug/kg ND 9.9 07/17/18 10:361.3 Anthracene ug/kg ND 9.9 07/17/18 10:361.4 Benzo(a)anthracene ug/kg ND 9.9 07/17/18 10:360.70 Benzo(a)pyrene ug/kg ND 9.9 07/17/18 10:361.1 Benzo(b)fluoranthene ug/kg ND 9.9 07/17/18 10:360.66 Benzo(g,h,i)perylene ug/kg ND 9.9 07/17/18 10:362.6 Benzo(k)fluoranthene ug/kg ND 9.9 07/17/18 10:361.5 Chrysene ug/kg ND 9.9 07/17/18 10:361.8 Dibenz(a,h)anthracene ug/kg ND 9.9 07/17/18 10:361.8 Fluoranthene ug/kg ND 9.9 07/17/18 10:360.82 Fluorene ug/kg ND 9.9 07/17/18 10:361.6 Indeno(1,2,3-cd)pyrene ug/kg ND 9.9 07/17/18 10:362.8 Naphthalene ug/kg ND 9.9 07/17/18 10:362.3 Phenanthrene ug/kg ND 9.9 07/17/18 10:361.5 Pyrene ug/kg ND 9.9 07/17/18 10:361.8 2-Fluorobiphenyl (S)%47 10-110 07/17/18 10:36 Nitrobenzene-d5 (S)%53 10-128 07/17/18 10:36 Terphenyl-d14 (S)%59 39-119 07/17/18 10:36 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 2322226LABORATORY CONTROL SAMPLE: LCSSpike 1-Methylnaphthalene ug/kg 19.433.8 57 44-130 2-Methylnaphthalene ug/kg 20.133.8 59 41-134 Acenaphthene ug/kg 20.033.8 59 52-123 Acenaphthylene ug/kg 18.433.8 55 49-116 Anthracene ug/kg 19.233.8 57 41-133 Benzo(a)anthracene ug/kg 19.533.8 58 56-130 Benzo(a)pyrene ug/kg 18.533.8 55 51-136 Benzo(b)fluoranthene ug/kg 17.833.8 53 37-149 Benzo(g,h,i)perylene ug/kg 17.133.8 51 39-127 Benzo(k)fluoranthene ug/kg 21.233.8 63 45-139 Chrysene ug/kg 20.233.8 60 59-127 Dibenz(a,h)anthracene ug/kg 18.133.8 54 37-139 Fluoranthene ug/kg 19.133.8 57 53-132 Fluorene ug/kg 18.833.8 56 45-127 Indeno(1,2,3-cd)pyrene ug/kg 18.933.8 56 35-145 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 07/30/2018 01:01 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 9 of 58 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92391723 Little Mountain Creek Sediment Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 2322226LABORATORY CONTROL SAMPLE: LCSSpike Naphthalene ug/kg 20.233.8 60 45-123 Phenanthrene ug/kg 18.833.8 56 50-125 Pyrene ug/kg 18.933.8 56 52-132 2-Fluorobiphenyl (S)%58 10-110 Nitrobenzene-d5 (S)%66 10-128 Terphenyl-d14 (S)%66 39-119 Parameter Units MS Result % Rec Limits Qualifiers% RecConc. 2322227MATRIX SPIKE SAMPLE: MSSpike Result 35403561001 1-Methylnaphthalene ug/kg 11.2 M133.3 33 50-1501.2U 2-Methylnaphthalene ug/kg 11.5 M133.3 34 50-1501.1U Acenaphthene ug/kg 11.5 M133.3 35 50-1501.5U Acenaphthylene ug/kg 10.5 M133.3 32 50-1501.3U Anthracene ug/kg 11.0 M133.3 33 50-1501.4U Benzo(a)anthracene ug/kg 11.3 M133.3 34 50-1500.72U Benzo(a)pyrene ug/kg 10.6 M133.3 32 50-1501.1U Benzo(b)fluoranthene ug/kg 11.0 M133.3 33 50-1500.68U Benzo(g,h,i)perylene ug/kg 9.2J M133.3 27 50-1502.6U Benzo(k)fluoranthene ug/kg 11.7 M133.3 35 50-1501.5U Chrysene ug/kg 11.2 M133.3 34 50-1501.8U Dibenz(a,h)anthracene ug/kg 9.7J M133.3 29 50-1501.8U Fluoranthene ug/kg 11.2 M133.3 34 50-1500.84U Fluorene ug/kg 11.0 M133.3 33 50-1501.6U Indeno(1,2,3-cd)pyrene ug/kg 10.3 M133.3 31 50-1502.8U Naphthalene ug/kg 11.4 M133.3 34 50-1502.3U Phenanthrene ug/kg 11.0 M133.3 33 50-1501.5U Pyrene ug/kg 11.2 M133.3 33 50-1501.8U 2-Fluorobiphenyl (S)%32 10-110 Nitrobenzene-d5 (S)%36 10-128 Terphenyl-d14 (S)%S23539-119 Parameter Units Dup Result Max RPD QualifiersRPDResult 35403557001 2322228SAMPLE DUPLICATE: 1-Methylnaphthalene ug/kg 157 IO330161 2-Methylnaphthalene ug/kg 25.3J IO3022.5J Acenaphthene ug/kg ND IO3063.0J Acenaphthylene ug/kg ND IO3014.3U Anthracene ug/kg 112 27 30147 Benzo(a)anthracene ug/kg ND IO307.8U Benzo(a)pyrene ug/kg ND IO3012.1U Benzo(b)fluoranthene ug/kg ND IO307.4U Benzo(g,h,i)perylene ug/kg ND IO3028.5U REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 07/30/2018 01:01 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 10 of 58 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92391723 Little Mountain Creek Sediment Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units Dup Result Max RPD QualifiersRPDResult 35403557001 2322228SAMPLE DUPLICATE: Benzo(k)fluoranthene ug/kg ND IO3016.5U Chrysene ug/kg ND IO3019.7U Dibenz(a,h)anthracene ug/kg ND IO3019.7U Fluoranthene ug/kg 101J IO3092.1J Fluorene ug/kg 77.9J IO30128 Indeno(1,2,3-cd)pyrene ug/kg ND IO3030.7U Naphthalene ug/kg 105J IO3095.7J Phenanthrene ug/kg ND IO3016.5U Pyrene ug/kg 283 IO1030255 2-Fluorobiphenyl (S)%0 S40 Nitrobenzene-d5 (S)%0 D3,P3,S40 Terphenyl-d14 (S)%0 S40 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 07/30/2018 01:01 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 11 of 58 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92391723 Little Mountain Creek Sediment Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 418938 ASTM D2974-87 ASTM D2974-87 Dry Weight/Percent Moisture Associated Lab Samples:92391723001, 92391723002, 92391723003 Parameter Units Dup Result Max RPD QualifiersRPDResult 92391652003 2322330SAMPLE DUPLICATE: Percent Moisture %12.9 5 2513.6 Parameter Units Dup Result Max RPD QualifiersRPDResult 92391774001 2322331SAMPLE DUPLICATE: Percent Moisture %36.8 0 2536.8 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 07/30/2018 01:01 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 12 of 58 #=QL# QUALIFIERS Pace Project No.: Project: 92391723 Little Mountain Creek Sediment DEFINITIONS DF - Dilution Factor, if reported, represents the factor applied to the reported data due to dilution of the sample aliquot. ND - Not Detected at or above adjusted reporting limit. TNTC - Too Numerous To Count J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit. MDL - Adjusted Method Detection Limit. PQL - Practical Quantitation Limit. RL - Reporting Limit - The lowest concentration value that meets project requirements for quantitative data with known precision and bias for a specific analyte in a specific matrix. S - Surrogate 1,2-Diphenylhydrazine decomposes to and cannot be separated from Azobenzene using Method 8270. The result for each analyte is a combined concentration. Consistent with EPA guidelines, unrounded data are displayed and have been used to calculate % recovery and RPD values. LCS(D) - Laboratory Control Sample (Duplicate) MS(D) - Matrix Spike (Duplicate) DUP - Sample Duplicate RPD - Relative Percent Difference NC - Not Calculable. SG - Silica Gel - Clean-Up U - Indicates the compound was analyzed for, but not detected. Acid preservation may not be appropriate for 2 Chloroethylvinyl ether. A separate vial preserved to a pH of 4-5 is recommended in SW846 Chapter 4 for the analysis of Acrolein and Acrylonitrile by EPAMethod 8260. N-Nitrosodiphenylamine decomposes and cannot be separated from Diphenylamine using Method 8270. The result reported for each analyte is a combined concentration. Pace Analytical is TNI accredited. Contact your Pace PM for the current list of accredited analytes. TNI - The NELAC Institute. LABORATORIES Pace Analytical Services - CharlottePASI-C ANALYTE QUALIFIERS Sample was diluted due to the presence of high levels of non-target analytes or other matrix interference.D3 The internal standard response was outside the laboratory acceptance limits confirmed by reanalysis. The results reported are from the most QC compliant analysis.IO Matrix spike recovery exceeded QC limits. Batch accepted based on laboratory control sample (LCS) recovery.M1 Sample extract could not be concentrated to the routine final volume, resulting in elevated reporting limits.P3 Surrogate recovery outside laboratory control limits.S0 Surrogate recovery outside laboratory control limits due to matrix interferences (confirmed by similar results from sample re-analysis).S2 Surrogate recovery not evaluated against control limits due to sample dilution.S4 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 07/30/2018 01:01 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 13 of 58 #=CR# QUALITY CONTROL DATA CROSS REFERENCE TABLE Pace Project No.: Project: 92391723 Little Mountain Creek Sediment Lab ID Sample ID QC Batch Method QC Batch Analytical Method Analytical Batch 92391723001 418842 419076ABL-SD007-F005 EPA 3546 EPA 8082A 92391723002 418842 419076ABL-SD007-D005 EPA 3546 EPA 8082A 92391723003 418842 419076ABL-SD008-F005 EPA 3546 EPA 8082A 92391723001 418920 419465ABL-SD007-F005 EPA 3546 EPA 8270D by SIM 92391723002 418920 419465ABL-SD007-D005 EPA 3546 EPA 8270D by SIM 92391723003 418920 419465ABL-SD008-F005 EPA 3546 EPA 8270D by SIM 92391723001 418938ABL-SD007-F005 ASTM D2974-87 92391723002 418938ABL-SD007-D005 ASTM D2974-87 92391723003 418938ABL-SD008-F005 ASTM D2974-87 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 07/30/2018 01:01 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 14 of 58 Page 15 of 58 Page 16 of 58 Page 17 of 58 Thisreportshouldnotbereproduced,exceptinfull, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Theresultsrelateonlytothesamplesincludedinthisreport. Report of Laboratory Analysis www.pacelabs.com Pace Analytical Services,Inc. 1700 Elm Street Minneapolis, MN 55414 Phone: 612.607.1700 Fax: 612.607.6444 Client - Charlotte PACE Charlotte 9800 Kincey Ave. Huntersville NC 28078 REPORT OF LABORATORY ANALYSIS FOR PCBs This report has been reviewed by: Invoicing & Reporting Options: Report Information: Report Prepared Date: July 30, 2018 Pace Project #: 10439556 Sample Receipt Date: 07/14/2018 Client Project #: 92391723 Alcoa-Badin Works ( Client Sub PO #: N/A The report provided has been invoiced as a Level 2 PCB Report. If an upgrade of this report package is requested, an additional charge may be applied. Please review the attached invoice for accuracy and forward anyquestions toNathan Boberg,your Pace Project Manager. State Cert #: 27700 Report Prepared for: Page 1 of 41Report No.....10439556_1668_209_DFR July 30, 2018 Scott Unze, Project Manager (612) 607-6383 (612) 607-6444 (fax) scott.unze@pacelabs.com Page 18 of 58 Pace Analytical Services,Inc. 1700 Elm Street Minneapolis, MN 55414 Phone: 612.607.1700 Fax: 612.607.6444 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. This report presents the results from the analyses performed on three samples submitted by a representative of Pace Analytical - NC. The samples were analyzed for the presence or absence of polychlorinated biphenyl (PCB) congeners using USEPA Method 1668A. Reporting limits were set to 25-75 parts-per-trillion and adjusted for the amount of dry sample extracted. The dilution level noted on the data tables is being adjusted to allow the correct data flags to populate the electronic deliverables as well as the data tables. Samples and MDL extracts were analyzed at elevated volumes. That volume is being treated as a 1x dilution for calculation purposes, with larger dilutions being factored from that volume. The standard reporting limits were not adjusted since the limits remained within the calibration range even after dilutions were applied. The recoveries of the isotopically-labeled PCB internal standards in the sample extracts ranged from 43-114%. All of the labeled standard recoveries obtained for this project were within the target ranges specified in Method 1668A. Since the quantification of the native congeners was based on isotope dilution and internal standard methodology, the data were automatically corrected for variation in recovery and accurate values were obtained. Incorrect isotope ratios were obtained for selected PCB congeners. The affected congeners were flagged "I" on the results table. A laboratory method blank was prepared and analyzed with the sample batch as part of our routine quality control procedures. The results show the blank to be free of PCB congeners at the reporting limits. This indicates that the sample preparation procedures did not significantly contribute to the PCB content of the sample material. Laboratory spike samples were also prepared with the sample batch using reference material that had been fortified with native standards. The results show that the spiked native compounds were recovered at 71-125%, with relative percent differences of 0.0-22.5%. The RPD for the DiCB congeners in solid matrix spike pair was above the 20% limit used by Pace analytical. This could indicate a higher than normal variability in the Di-CB results from the associated sample extracts. However, these values were within method limits. Matrix spikes were not extracted with these sample batches. DISCUSSION Page 2 of 41Report No.....10439556_1668_209_DFR Page 19 of 58 REPORT OFLABORATORY ANALYSIS This report shallnot bereproduced,exceptin full, withoutthe written consentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Report No.....10439556 Minnesota Laboratory Certifications Authority Certificate #Authority Certificate # A2LA 2926.01 Minnesota - Pet 1240 Alabama 40770 Mississippi MN00064 Alaska - DW MN00064 Montana CERT0092 Alaska - UST 17-009 Nebraska NE-OS-18-06 Arizona AZ0014 Nevada MN00064 Arkansas - DW MN00064 New Hampshire 2081 Arkansas - WW 88-0680 New Jersey (NE MN002 CNMI Saipan MP0003 New York 11647 California 2929 North Carolina 27700 Colorado MN00064 North Carolina -27700 Connecticut PH-0256 North Carolina -530 EPA Region 8+via MN 027-053 North Dakota R-036 Florida (NELAP E87605 Ohio - DW 41244 Georgia 959 Ohio - VAP CL101 Guam 17-001r Oklahoma 9507 Hawaii MN00064 Oregon - Primar MN300001 Idaho MN00064 Oregon - Secon MN200001 Illinois 200011 Pennsylvania 68-00563 Indiana C-MN-01 Puerto Rico MN00064 Iowa 368 South Carolina 74003 Kansas E-10167 South Dakota NA Kentucky - DW 90062 Tennessee TN02818 Kentucky -WW 90062 Texas T104704192 Louisiana - DE 03086 Utah (NELAP)MN00064 Louisiana - DW MN00064 Virginia 460163 Maine MN00064 Washington C486 Maryland 322 West Virginia - 382 Massachusetts M-MN064 West Virginia - 9952C Michigan 9909 Wisconsin 999407970 Minnesota 027-053-137 Wyoming - UST 2926.01 Minnesota - De via MN 027-053 Page 3 of 41Report No.....10439556_1668_209_DFR Page 20 of 58 Appendix A Sample Management Pace Analytical Services, Inc.Page 4 of 41Report No.....10439556_1668_209_DFR Page 21 of 58 Page 5 of 41Report No.....10439556_1668_209_DFR Page 22 of 58 7/16/18 Page 6 of 41Report No.....10439556_1668_209_DFR Page 23 of 58 10439556 Page 7 of 41Report No.....10439556_1668_209_DFR Page 24 of 58 7/16/18 Page 8 of 41Report No.....10439556_1668_209_DFR Page 25 of 58 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Report No.....10439556 Reporting Flags A = B = C = D = E = I = J = L = Nn = P = R = S = U = V = X = Y = * = Reporting Limit based on signal to noise Less than 10x higher than method blank level Result obtained from confirmation analysis Result obtained from analysis of diluted sample Exceeds calibration range Interferencepresent Estimated value Suppressive interference,analyte may be biased low Value obtained from additional analysis PCDEInterference Recovery outside target range Peak saturated Analyte not detected Result verified by confirmation analysis %DExceeds limits Calculated using average of daily RFs SeeDiscussion Page 9 of 41Report No.....10439556_1668_209_DFR Page 26 of 58 Appendix B Sample Analysis Summary Pace Analytical Services, Inc.Page 10 of 41Report No.....10439556_1668_209_DFR Page 27 of 58 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Client - PACE Charlotte Client's Sample ID Lab Sample ID Filename Injected ByTotal Amount Extracted% Moisture Dry Weight Extracted ICAL ID CCal Filename(s)Method Blank ID BLANK-63507P180727A_01 P180727A02 10.3 g 11.211.6 gCVS P180727A_11 92391723001 ABL-SD007-F005 MatrixDilution Collected Received ExtractedAnalyzed 07/27/2018 10:2207/17/2018 15:00 07/14/2018 09:30 07/12/2018 08:35 NASolid Method 1668A Polychlorobiphenyl Sample Analysis Results PCB Isomer RT % Recoveryng's Foundng's AddedIUPACRatio LabeledAnalytes13C-2-MoCB 1 2.75 2.09.563 1.29 6413C-4-MoCB 3 2.83 2.012.415 1.16 5813C-2,2'-DiCB 4 1.53 2.012.726 0.874 4413C-4,4'-DiCB 15 1.73 2.019.950 1.38 6913C-2,2',6-TrCB 19 1.02 2.016.571 0.950 4713C-3,4,4'-TrCB 37 1.13 2.027.693 1.94 9713C-2,2',6,6'-TeCB 54 0.88 2.020.264 1.68 8413C-3,4,4',5-TeCB 81 0.83 2.034.825 2.12 10613C-3,3',4,4'-TeCB 77 0.79 2.035.412 1.80 9013C-2,2',4,6,6'-PeCB 104 1.71 2.026.301 1.24 6213C-2,3,3',4,4'-PeCB 105 1.58 2.038.989 1.71 8513C-2,3,4,4',5-PeCB 114 1.56 2.038.301 1.71 8513C-2,3',4,4',5-PeCB 118 1.63 2.037.765 1.84 9213C-2,3',4,4',5'-PeCB 123 1.58 2.037.413 1.84 9213C-3,3',4,4',5-PeCB 126 1.69 2.042.175 1.91 9513C-2,2',4,4',6,6'-HxCB 155 1.27 2.032.310 1.04 5213C-HxCB(156/157)156/157 1.31 4.045.232 2.77 6913C-2,3',4,4',5,5'-HxCB 167 1.32 2.044.008 1.33 6613C-3,3',4,4',5,5'-HxCB 169 1.30 2.048.519 1.32 6613C-2,2',3,4',5,6,6'-HpCB 188 1.15 2.038.234 1.27 6413C-2,3,3',4,4',5,5'-HpCB 189 1.04 2.051.025 1.43 7113C-2,2',3,3',5,5',6,6'-OcCB 202 0.86 2.043.723 1.19 5913C-2,3,3',4,4',5,5',6-OcCB 205 0.91 2.053.094 1.32 6613C-2,2',3,3',4,4',5,5',6-NoCB 206 0.77 2.054.516 1.31 6613C-2,2',3,3',4,5,5',6,6'-NoCB 208 0.85 2.050.486 1.15 5713C--DeCB 209 0.66 2.055.960 1.15 58 CleanupStandards13C-2,4,4'-TrCB 28 1.05 2.023.282 1.94 9713C-2,3,3',5,5'-PeCB 111 1.53 2.035.378 1.36 6813C-2,2',3,3',5,5',6-HpCB 178 1.09 2.041.370 1.13 56 Recovery Standards13C-2,5-DiCB 9 1.56 2.015.205 NA NA13C-2,2',5,5'-TeCB 52 0.85 2.025.261 NA NA13C-2,2',4,5,5'-PeCB 101 1.61 2.032.561 NA NA13C-2,2',3,4,4',5'-HxCB 138 1.24 2.040.934 NA NA13C-2,2',3,3',4,4',5,5'-OcCB 194 0.88 2.052.706 NA NA Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = NanogramsResultsreportedonadryweightbasis Page 11 of 41Report No.....10439556_1668_209_DFR Page 28 of 58 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses Resultsreportedon a dryweight basis ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SD007-F005 P180727A_11Lab Sample ID 92391723001 Co-elutions RT ng/Kg EMLEMPCConcentration ng/KgIUPACRatio ng/Kg 1 ---ND------24.32---ND------24.33---ND------24.3 4 ---ND------24.35---ND------24.36---ND------24.37---ND------24.38---ND------24.3 9 ---ND------24.310---ND------24.311---ND------238 12 12/13 ---ND------48.51312/13 ---ND------48.514---ND------24.3 15 ---ND------32.016---ND------24.317---ND------24.31818/30 ---ND------48.519---ND------24.32020/28 1.01 16523.299 ---1252121/33 ---ND------13122---ND------92.2 23 ---ND------24.324---ND------24.325---ND------24.3 26 26/29 ---ND------48.527---ND------24.32820/28 1.01 (165)23.299 ---125 29 26/29 ---ND------48.53018/30 ---ND------48.5311.05 18022.980 ---126320.99 25.720.465 ---24.33321/33 ---ND------131 34 ---ND------24.335---ND------24.336---ND------24.3 37 1.01 81.827.693 ---51.538---ND------24.339---ND------24.3 40 40/41/71 ---ND------1464140/41/71 ---ND------146420.80 66.626.955 ---48.54343/73 ---ND------48.54444/47/65 0.80 21526.402 ---1464545/51 ---ND------97.146---ND------48.54744/47/65 0.80 (215)26.402 ---146 48 ---ND------48.5 Page 12 of 41Report No.....10439556_1668_209_DFR Page 29 of 58 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses Resultsreportedon a dryweight basis ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SD007-F005 P180727A_11Lab Sample ID 92391723001 Co-elutions RT ng/Kg EMLEMPCConcentration ng/KgIUPACRatio ng/Kg 49 49/69 0.77 16125.848 ---97.15050/53 ---ND------97.15145/51 ---ND------97.1 52 0.80 24925.312 ---1505350/53 ---ND------97.154---ND------48.555---ND------48.5560.80 22631.521 ---48.5 57 ---ND------48.558---ND------48.55959/62/75 ---ND------146 60 0.81 14031.739 ---48.56161/70/74/76 0.80 88630.448 ---1946259/62/75 ---ND------146 63 ---ND------48.5640.83 18027.726 ---48.56544/47/65 0.80 (215)26.402 ---146660.78 46830.817 ---81.567---ND------48.568---ND------48.56949/69 0.77 (161)25.848 ---97.17061/70/74/76 0.80 (886)30.448 ---194 71 40/41/71 ---ND------14672---ND------48.57343/73 ---ND------48.5 74 61/70/74/76 0.80 (886)30.448 ---1947559/62/75 ---ND------1467661/70/74/76 0.80 (886)30.448 ---194 77 0.79 10535.429 ---48.578---ND------48.579---ND------48.580---ND------48.581---ND------48.5 82 1.62 51.335.026 ---48.583---ND------48.584---ND------48.5 85 85/116/117 ---ND------1468686/87/97/108/119/125 ---ND------2918786/87/97/108/119/125 ---ND------291 88 88/91 ---ND------97.189---ND------48.59090/101/113 1.52 19132.611 ---1469188/91 ---ND------97.192---ND------48.59393/98/100/102 ---ND------19494---ND------48.5951.54 10629.526 ---92.2 96 ---ND------48.5 Page 13 of 41Report No.....10439556_1668_209_DFR Page 30 of 58 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses Resultsreportedon a dryweight basis ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SD007-F005 P180727A_11Lab Sample ID 92391723001 Co-elutions RT ng/Kg EMLEMPCConcentration ng/KgIUPACRatio ng/Kg 97 86/87/97/108/119/125 ---ND------2919893/98/100/102 ---ND------194991.55 12933.198 ---48.5 100 93/98/100/102 ---ND------19410190/101/113 1.52 (191)32.611 ---14610293/98/100/102 ---ND------194103---ND------48.5104---ND------48.5 105 1.59 23239.022 ---48.5106---ND------48.5107107/124 ---ND------97.1 108 86/87/97/108/119/125 ---ND------291109---ND------48.5110110/115 1.60 33534.674 ---97.1 111 ---ND------48.5112---ND------48.511390/101/113 1.52 (191)32.611 ---146114---ND------48.5115110/115 1.60 (335)34.674 ---97.111685/116/117 ---ND------14611785/116/117 ---ND------1461181.60 35437.798 ---62.1 119 86/87/97/108/119/125 ---ND------291120---ND------48.5121---ND------48.5 122 ---ND------48.5123---ND------48.5124107/124 ---ND------97.1 125 86/87/97/108/119/125 ---ND------291126---ND------48.5127---ND------48.5128128/166 ---ND------97.1129129/138/163 1.21 24940.985 ---146 130 ---ND------48.5131---ND------48.51321.40 55.637.899 ---48.5 133 ---ND------48.5134134/143 ---ND------97.1135135/151 ---ND------97.1 136 ---ND------48.5137---ND------48.5138129/138/163 1.21 (249)40.985 ---146139139/140 ---ND------97.1140139/140 ---ND------97.1141---ND------48.5142---ND------48.5143134/143 ---ND------97.1 144 ---ND------48.5 Page 14 of 41Report No.....10439556_1668_209_DFR Page 31 of 58 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses Resultsreportedon a dryweight basis ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SD007-F005 P180727A_11Lab Sample ID 92391723001 Co-elutions RT ng/Kg EMLEMPCConcentration ng/KgIUPACRatio ng/Kg 145 ---ND------48.5146---ND------48.5147147/149 1.27 16136.574 ---97.1 148 ---ND------48.5149147/149 1.27 (161)36.574 ---97.1150---ND------48.5151135/151 ---ND------97.1152---ND------48.5 153 153/168 1.26 19639.676 ---97.1154---ND------48.5155---ND------48.5 156 156/157 ---ND------97.1157156/157 ---ND------97.1158---ND------48.5 159 ---ND------48.5160---ND------48.5161---ND------48.5162---ND------48.5163129/138/163 1.21 (249)40.985 ---146164---ND------48.5165---ND------48.5166128/166 ---ND------97.1 167 ---ND------48.5168153/168 1.26 (196)39.676 ---97.1169---ND------48.5 170 0.90 64.947.898 ---48.5171171/173 ---ND------97.1172---ND------48.5 173 171/173 ---ND------97.11741.00 82.243.203 ---48.5175---ND------48.5176---ND------48.5177---ND------48.5 178 ---ND------48.5179---ND------48.5180180/193 1.04 16546.607 ---97.1 181 ---ND------48.5182---ND------48.5183183/185 ---ND------97.1 184 ---ND------48.5185183/185 ---ND------97.1186---ND------48.51871.03 10142.326 ---48.5188---ND------48.5189---ND------48.5190---ND------48.5191---ND------48.5 192 ---ND------48.5 Page 15 of 41Report No.....10439556_1668_209_DFR Page 32 of 58 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses Resultsreportedon a dryweight basis ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SD007-F005 P180727A_11Lab Sample ID 92391723001 Co-elutions RT ng/Kg EMLEMPCConcentration ng/KgIUPACRatio ng/Kg 193 180/193 1.04 (165)46.607 ---97.1194---ND------72.8195---ND------72.8 196 ---ND------72.8197197/200 ---ND------146198198/199 ---ND------146199198/199 ---ND------146200197/200 ---ND------146 201 ---ND------72.8202---ND------72.8203---ND------72.8 204 ---ND------72.8205---ND------72.8206---ND------72.8 207 ---ND------72.8208---ND------72.8209---ND------72.8 Page 16 of 41Report No.....10439556_1668_209_DFR Page 33 of 58 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SD007-F005 P180727A_11 Sample Analysis Results Lab Sample ID 92391723001 Congener Group Concentration ng/Kg Total MonochloroBiphenyls ND TotalDichloroBiphenyls ND Total TrichloroBiphenyls 453 Total TetrachloroBiphenyls 2700 TotalPentachloroBiphenyls 1400 TotalHexachloroBiphenyls 662 TotalHeptachloroBiphenyls 413 Total Octachloro Biphenyls ND TotalNonachloroBiphenyls ND DecachloroBiphenyls ND TotalPCBs 5620 Results reported on a dry weight basis ND = Not Detected Page 17 of 41Report No.....10439556_1668_209_DFR Page 34 of 58 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Client - PACE Charlotte Client's Sample ID Lab Sample ID Filename Injected ByTotal Amount Extracted% Moisture Dry Weight Extracted ICAL ID CCal Filename(s)Method Blank ID BLANK-63507P180727A_01 P180727A02 10.00 g 9.111.0 gCVS P180727A_12 92391723002 ABL-SD007-D005 MatrixDilution Collected Received ExtractedAnalyzed 07/27/2018 11:2107/17/2018 15:00 07/14/2018 09:30 07/12/2018 08:40 NASolid Method 1668A Polychlorobiphenyl Sample Analysis Results PCB Isomer RT % Recoveryng's Foundng's AddedIUPACRatio LabeledAnalytes13C-2-MoCB 1 2.68 2.09.575 1.43 7213C-4-MoCB 3 3.45 2.012.415 1.18 5913C-2,2'-DiCB 4 1.60 2.012.714 0.864 4313C-4,4'-DiCB 15 1.57 2.019.877 1.10 5513C-2,2',6-TrCB 19 1.19 2.016.546 0.991 5013C-3,4,4'-TrCB 37 1.17 2.027.692 1.70 8513C-2,2',6,6'-TeCB 54 0.82 2.020.180 1.45 7313C-3,4,4',5-TeCB 81 0.83 2.034.824 2.08 10413C-3,3',4,4'-TeCB 77 0.77 2.035.411 1.56 7813C-2,2',4,6,6'-PeCB 104 1.62 2.026.300 1.31 6513C-2,3,3',4,4'-PeCB 105 1.66 2.039.004 1.71 8613C-2,3,4,4',5-PeCB 114 1.58 2.038.317 1.75 8813C-2,3',4,4',5-PeCB 118 1.64 2.037.764 1.75 8813C-2,3',4,4',5'-PeCB 123 1.57 2.037.428 1.67 8313C-3,3',4,4',5-PeCB 126 1.55 2.042.190 1.88 9413C-2,2',4,4',6,6'-HxCB 155 1.30 2.032.325 1.31 6613C-HxCB(156/157)156/157 1.32 4.045.231 3.22 8113C-2,3',4,4',5,5'-HxCB 167 1.43 2.044.023 1.61 8013C-3,3',4,4',5,5'-HxCB 169 1.27 2.048.534 1.76 8813C-2,2',3,4',5,6,6'-HpCB 188 1.05 2.038.250 1.14 5713C-2,3,3',4,4',5,5'-HpCB 189 1.08 2.051.023 1.33 6713C-2,2',3,3',5,5',6,6'-OcCB 202 0.88 2.043.705 1.14 5713C-2,3,3',4,4',5,5',6-OcCB 205 0.93 2.053.092 1.41 7113C-2,2',3,3',4,4',5,5',6-NoCB 206 0.80 2.054.515 1.27 6413C-2,2',3,3',4,5,5',6,6'-NoCB 208 0.84 2.050.506 1.10 5513C--DeCB 209 0.71 2.055.981 1.20 60 CleanupStandards13C-2,4,4'-TrCB 28 1.16 2.023.265 1.79 9013C-2,3,3',5,5'-PeCB 111 1.59 2.035.377 1.45 7313C-2,2',3,3',5,5',6-HpCB 178 1.05 2.041.369 1.36 68 Recovery Standards13C-2,5-DiCB 9 1.60 2.015.180 NA NA13C-2,2',5,5'-TeCB 52 0.80 2.025.261 NA NA13C-2,2',4,5,5'-PeCB 101 1.59 2.032.577 NA NA13C-2,2',3,4,4',5'-HxCB 138 1.29 2.040.950 NA NA13C-2,2',3,3',4,4',5,5'-OcCB 194 0.90 2.052.704 NA NA Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = NanogramsResultsreportedonadryweightbasis Page 18 of 41Report No.....10439556_1668_209_DFR Page 35 of 58 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses Resultsreportedon a dryweight basis ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SD007-D005 P180727A_12Lab Sample ID 92391723002 Co-elutions RT ng/Kg EMLEMPCConcentration ng/KgIUPACRatio ng/Kg 1 ---ND------25.02---ND------25.03---ND------25.0 4 ---ND------25.05---ND------25.06---ND------25.07---ND------25.08---ND------25.0 9 ---ND------25.010---ND------25.011---ND------245 12 12/13 ---ND------50.01312/13 ---ND------50.014---ND------25.0 15 ---ND------33.016---ND------25.017---ND------25.01818/30 ---ND------50.019---ND------25.02020/28 ---ND------1292121/33 ---ND------13522---ND------95.0 23 ---ND------25.024---ND------25.025---ND------25.0 26 26/29 ---ND------50.027---ND------25.02820/28 ---ND------129 29 26/29 ---ND------50.03018/30 ---ND------50.031---ND------13032---ND------25.03321/33 ---ND------135 34 ---ND------25.035---ND------25.036---ND------25.0 37 ---ND------53.038---ND------25.039---ND------25.0 40 40/41/71 ---ND------1504140/41/71 ---ND------15042---ND------50.04343/73 ---ND------50.04444/47/65 ---ND------1504545/51 ---ND------10046---ND------50.04744/47/65 ---ND------150 48 ---ND------50.0 Page 19 of 41Report No.....10439556_1668_209_DFR Page 36 of 58 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses Resultsreportedon a dryweight basis ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SD007-D005 P180727A_12Lab Sample ID 92391723002 Co-elutions RT ng/Kg EMLEMPCConcentration ng/KgIUPACRatio ng/Kg 49 49/69 ---ND------1005050/53 ---ND------1005145/51 ---ND------100 52 ---ND------1545350/53 ---ND------10054---ND------50.055---ND------50.056---ND------50.0 57 ---ND------50.058---ND------50.05959/62/75 ---ND------150 60 ---ND------50.06161/70/74/76 ---ND------2006259/62/75 ---ND------150 63 ---ND------50.064---ND------50.06544/47/65 ---ND------15066---ND------84.067---ND------50.068---ND------50.06949/69 ---ND------1007061/70/74/76 ---ND------200 71 40/41/71 ---ND------15072---ND------50.07343/73 ---ND------50.0 74 61/70/74/76 ---ND------2007559/62/75 ---ND------1507661/70/74/76 ---ND------200 77 ---ND------50.078---ND------50.079---ND------50.080---ND------50.081---ND------50.0 82 ---ND------50.083---ND------50.084---ND------50.0 85 85/116/117 ---ND------1508686/87/97/108/119/125 ---ND------3008786/87/97/108/119/125 ---ND------300 88 88/91 ---ND------10089---ND------50.09090/101/113 ---ND------1509188/91 ---ND------10092---ND------50.09393/98/100/102 ---ND------20094---ND------50.095---ND------95.0 96 ---ND------50.0 Page 20 of 41Report No.....10439556_1668_209_DFR Page 37 of 58 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses Resultsreportedon a dryweight basis ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SD007-D005 P180727A_12Lab Sample ID 92391723002 Co-elutions RT ng/Kg EMLEMPCConcentration ng/KgIUPACRatio ng/Kg 97 86/87/97/108/119/125 ---ND------3009893/98/100/102 ---ND------20099---ND------50.0 100 93/98/100/102 ---ND------20010190/101/113 ---ND------15010293/98/100/102 ---ND------200103---ND------50.0104---ND------50.0 105 ---ND------50.0106---ND------50.0107107/124 ---ND------100 108 86/87/97/108/119/125 ---ND------300109---ND------50.0110110/115 ---ND------100 111 ---ND------50.0112---ND------50.011390/101/113 ---ND------150114---ND------50.0115110/115 ---ND------10011685/116/117 ---ND------15011785/116/117 ---ND------150118---ND------64.0 119 86/87/97/108/119/125 ---ND------300120---ND------50.0121---ND------50.0 122 ---ND------50.0123---ND------50.0124107/124 ---ND------100 125 86/87/97/108/119/125 ---ND------300126---ND------50.0127---ND------50.0128128/166 ---ND------100129129/138/163 ---ND------150 130 ---ND------50.0131---ND------50.0132---ND------50.0 133 ---ND------50.0134134/143 ---ND------100135135/151 ---ND------100 136 ---ND------50.0137---ND------50.0138129/138/163 ---ND------150139139/140 ---ND------100140139/140 ---ND------100141---ND------50.0142---ND------50.0143134/143 ---ND------100 144 ---ND------50.0 Page 21 of 41Report No.....10439556_1668_209_DFR Page 38 of 58 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses Resultsreportedon a dryweight basis ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SD007-D005 P180727A_12Lab Sample ID 92391723002 Co-elutions RT ng/Kg EMLEMPCConcentration ng/KgIUPACRatio ng/Kg 145 ---ND------50.0146---ND------50.0147147/149 ---ND------100 148 ---ND------50.0149147/149 ---ND------100150---ND------50.0151135/151 ---ND------100152---ND------50.0 153 153/168 ---ND------100154---ND------50.0155---ND------50.0 156 156/157 ---ND------100157156/157 ---ND------100158---ND------50.0 159 ---ND------50.0160---ND------50.0161---ND------50.0162---ND------50.0163129/138/163 ---ND------150164---ND------50.0165---ND------50.0166128/166 ---ND------100 167 ---ND------50.0168153/168 ---ND------100169---ND------50.0 170 ---ND------50.0171171/173 ---ND------100172---ND------50.0 173 171/173 ---ND------100174---ND------50.0175---ND------50.0176---ND------50.0177---ND------50.0 178 ---ND------50.0179---ND------50.0180180/193 ---ND------100 181 ---ND------50.0182---ND------50.0183183/185 ---ND------100 184 ---ND------50.0185183/185 ---ND------100186---ND------50.0187---ND------50.0188---ND------50.0189---ND------50.0190---ND------50.0191---ND------50.0 192 ---ND------50.0 Page 22 of 41Report No.....10439556_1668_209_DFR Page 39 of 58 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses Resultsreportedon a dryweight basis ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SD007-D005 P180727A_12Lab Sample ID 92391723002 Co-elutions RT ng/Kg EMLEMPCConcentration ng/KgIUPACRatio ng/Kg 193 180/193 ---ND------100194---ND------75.0195---ND------75.0 196 ---ND------75.0197197/200 ---ND------150198198/199 ---ND------150199198/199 ---ND------150200197/200 ---ND------150 201 ---ND------75.0202---ND------75.0203---ND------75.0 204 ---ND------75.0205---ND------75.0206---ND------75.0 207 ---ND------75.0208---ND------75.0209---ND------75.0 Page 23 of 41Report No.....10439556_1668_209_DFR Page 40 of 58 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SD007-D005 P180727A_12 Sample Analysis Results Lab Sample ID 92391723002 Congener Group Concentration ng/Kg Total MonochloroBiphenyls ND TotalDichloroBiphenyls ND Total TrichloroBiphenyls ND Total TetrachloroBiphenyls ND TotalPentachloroBiphenyls ND TotalHexachloroBiphenyls ND TotalHeptachloroBiphenyls ND Total Octachloro Biphenyls ND TotalNonachloroBiphenyls ND DecachloroBiphenyls ND TotalPCBs ND Results reported on a dry weight basis ND = Not Detected Page 24 of 41Report No.....10439556_1668_209_DFR Page 41 of 58 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Client - PACE Charlotte Client's Sample ID Lab Sample ID Filename Injected ByTotal Amount Extracted% Moisture Dry Weight Extracted ICAL ID CCal Filename(s)Method Blank ID BLANK-63507P180727A_01 P180727A02 10.3 g 22.613.3 gCVS P180727A_13 92391723003 ABL-SD008-F005 MatrixDilution Collected Received ExtractedAnalyzed 07/27/2018 12:2107/17/2018 15:00 07/14/2018 09:30 07/12/2018 10:10 NASolid Method 1668A Polychlorobiphenyl Sample Analysis Results PCB Isomer RT % Recoveryng's Foundng's AddedIUPACRatio LabeledAnalytes13C-2-MoCB 1 2.66 2.09.575 1.32 6613C-4-MoCB 3 3.08 2.012.415 1.16 5813C-2,2'-DiCB 4 1.63 2.012.715 0.875 4413C-4,4'-DiCB 15 1.61 2.019.866 1.08 5413C-2,2',6-TrCB 19 1.09 2.016.547 0.910 4613C-3,4,4'-TrCB 37 1.10 2.027.676 1.59 8013C-2,2',6,6'-TeCB 54 0.82 2.020.181 1.42 7113C-3,4,4',5-TeCB 81 0.81 2.034.824 2.28 11413C-3,3',4,4'-TeCB 77 0.80 2.035.411 1.70 8513C-2,2',4,6,6'-PeCB 104 1.66 2.026.301 1.31 6513C-2,3,3',4,4'-PeCB 105 1.67 2.038.988 1.83 9213C-2,3,4,4',5-PeCB 114 1.55 2.038.317 1.77 8813C-2,3',4,4',5-PeCB 118 1.61 2.037.764 1.85 9313C-2,3',4,4',5'-PeCB 123 1.56 2.037.429 1.79 9013C-3,3',4,4',5-PeCB 126 1.57 2.042.174 1.91 9613C-2,2',4,4',6,6'-HxCB 155 1.19 2.032.309 1.19 6013C-HxCB(156/157)156/157 1.30 4.045.231 3.07 7713C-2,3',4,4',5,5'-HxCB 167 1.20 2.044.007 1.49 7513C-3,3',4,4',5,5'-HxCB 169 1.37 2.048.517 1.69 8413C-2,2',3,4',5,6,6'-HpCB 188 0.98 2.038.233 1.25 6313C-2,3,3',4,4',5,5'-HpCB 189 1.09 2.051.023 1.68 8413C-2,2',3,3',5,5',6,6'-OcCB 202 0.91 2.043.722 1.24 6213C-2,3,3',4,4',5,5',6-OcCB 205 1.01 2.053.092 1.59 7913C-2,2',3,3',4,4',5,5',6-NoCB 206 0.75 2.054.515 1.44 7213C-2,2',3,3',4,5,5',6,6'-NoCB 208 0.78 2.050.506 1.30 6513C--DeCB 209 0.75 2.055.980 1.42 71 CleanupStandards13C-2,4,4'-TrCB 28 1.10 2.023.266 1.73 8613C-2,3,3',5,5'-PeCB 111 1.59 2.035.361 1.63 8113C-2,2',3,3',5,5',6-HpCB 178 1.07 2.041.369 1.33 66 Recovery Standards13C-2,5-DiCB 9 1.60 2.015.169 NA NA13C-2,2',5,5'-TeCB 52 0.79 2.025.261 NA NA13C-2,2',4,5,5'-PeCB 101 1.56 2.032.577 NA NA13C-2,2',3,4,4',5'-HxCB 138 1.23 2.040.933 NA NA13C-2,2',3,3',4,4',5,5'-OcCB 194 0.90 2.052.726 NA NA Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = NanogramsResultsreportedonadryweightbasis Page 25 of 41Report No.....10439556_1668_209_DFR Page 42 of 58 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses Resultsreportedon a dryweight basis ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SD008-F005 P180727A_13Lab Sample ID 92391723003 Co-elutions RT ng/Kg EMLEMPCConcentration ng/KgIUPACRatio ng/Kg 1 ---ND------24.32---ND------24.33---ND------24.3 4 ---ND------24.35---ND------24.36---ND------24.37---ND------24.38---ND------24.3 9 ---ND------24.310---ND------24.311---ND------238 12 12/13 ---ND------48.61312/13 ---ND------48.614---ND------24.3 15 ---ND------32.116---ND------24.317---ND------24.31818/30 ---ND------48.619---ND------24.32020/28 ---ND------1252121/33 ---ND------13122---ND------92.3 23 ---ND------24.324---ND------24.325---ND------24.3 26 26/29 ---ND------48.627---ND------24.32820/28 ---ND------125 29 26/29 ---ND------48.63018/30 ---ND------48.631---ND------12632---ND------24.33321/33 ---ND------131 34 ---ND------24.335---ND------24.336---ND------24.3 37 ---ND------51.538---ND------24.339---ND------24.3 40 40/41/71 ---ND------1464140/41/71 ---ND------14642---ND------48.64343/73 ---ND------48.64444/47/65 ---ND------1464545/51 ---ND------97.146---ND------48.64744/47/65 ---ND------146 48 ---ND------48.6 Page 26 of 41Report No.....10439556_1668_209_DFR Page 43 of 58 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses Resultsreportedon a dryweight basis ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SD008-F005 P180727A_13Lab Sample ID 92391723003 Co-elutions RT ng/Kg EMLEMPCConcentration ng/KgIUPACRatio ng/Kg 49 49/69 ---ND------97.15050/53 ---ND------97.15145/51 ---ND------97.1 52 ---ND------1505350/53 ---ND------97.154---ND------48.655---ND------48.656---ND------48.6 57 ---ND------48.658---ND------48.65959/62/75 ---ND------146 60 ---ND------48.66161/70/74/76 ---ND------1946259/62/75 ---ND------146 63 ---ND------48.664---ND------48.66544/47/65 ---ND------14666---ND------81.667---ND------48.668---ND------48.66949/69 ---ND------97.17061/70/74/76 ---ND------194 71 40/41/71 ---ND------14672---ND------48.67343/73 ---ND------48.6 74 61/70/74/76 ---ND------1947559/62/75 ---ND------1467661/70/74/76 ---ND------194 77 ---ND------48.678---ND------48.679---ND------48.680---ND------48.681---ND------48.6 82 ---ND------48.683---ND------48.684---ND------48.6 85 85/116/117 ---ND------1468686/87/97/108/119/125 ---ND------2918786/87/97/108/119/125 ---ND------291 88 88/91 ---ND------97.189---ND------48.69090/101/113 ---ND------1469188/91 ---ND------97.192---ND------48.69393/98/100/102 ---ND------19494---ND------48.695---ND------92.3 96 ---ND------48.6 Page 27 of 41Report No.....10439556_1668_209_DFR Page 44 of 58 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses Resultsreportedon a dryweight basis ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SD008-F005 P180727A_13Lab Sample ID 92391723003 Co-elutions RT ng/Kg EMLEMPCConcentration ng/KgIUPACRatio ng/Kg 97 86/87/97/108/119/125 ---ND------2919893/98/100/102 ---ND------19499---ND------48.6 100 93/98/100/102 ---ND------19410190/101/113 ---ND------14610293/98/100/102 ---ND------194103---ND------48.6104---ND------48.6 105 ---ND------48.6106---ND------48.6107107/124 ---ND------97.1 108 86/87/97/108/119/125 ---ND------291109---ND------48.6110110/115 ---ND------97.1 111 ---ND------48.6112---ND------48.611390/101/113 ---ND------146114---ND------48.6115110/115 ---ND------97.111685/116/117 ---ND------14611785/116/117 ---ND------146118---ND------62.2 119 86/87/97/108/119/125 ---ND------291120---ND------48.6121---ND------48.6 122 ---ND------48.6123---ND------48.6124107/124 ---ND------97.1 125 86/87/97/108/119/125 ---ND------291126---ND------48.6127---ND------48.6128128/166 ---ND------97.1129129/138/163 ---ND------146 130 ---ND------48.6131---ND------48.6132---ND------48.6 133 ---ND------48.6134134/143 ---ND------97.1135135/151 ---ND------97.1 136 ---ND------48.6137---ND------48.6138129/138/163 ---ND------146139139/140 ---ND------97.1140139/140 ---ND------97.1141---ND------48.6142---ND------48.6143134/143 ---ND------97.1 144 ---ND------48.6 Page 28 of 41Report No.....10439556_1668_209_DFR Page 45 of 58 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses Resultsreportedon a dryweight basis ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SD008-F005 P180727A_13Lab Sample ID 92391723003 Co-elutions RT ng/Kg EMLEMPCConcentration ng/KgIUPACRatio ng/Kg 145 ---ND------48.6146---ND------48.6147147/149 ---ND------97.1 148 ---ND------48.6149147/149 ---ND------97.1150---ND------48.6151135/151 ---ND------97.1152---ND------48.6 153 153/168 ---ND------97.1154---ND------48.6155---ND------48.6 156 156/157 ---ND------97.1157156/157 ---ND------97.1158---ND------48.6 159 ---ND------48.6160---ND------48.6161---ND------48.6162---ND------48.6163129/138/163 ---ND------146164---ND------48.6165---ND------48.6166128/166 ---ND------97.1 167 ---ND------48.6168153/168 ---ND------97.1169---ND------48.6 170 ---ND------48.6171171/173 ---ND------97.1172---ND------48.6 173 171/173 ---ND------97.1174---ND------48.6175---ND------48.6176---ND------48.6177---ND------48.6 178 ---ND------48.6179---ND------48.6180180/193 ---ND------97.1 181 ---ND------48.6182---ND------48.6183183/185 ---ND------97.1 184 ---ND------48.6185183/185 ---ND------97.1186---ND------48.6187---ND------48.6188---ND------48.6189---ND------48.6190---ND------48.6191---ND------48.6 192 ---ND------48.6 Page 29 of 41Report No.....10439556_1668_209_DFR Page 46 of 58 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses Resultsreportedon a dryweight basis ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SD008-F005 P180727A_13Lab Sample ID 92391723003 Co-elutions RT ng/Kg EMLEMPCConcentration ng/KgIUPACRatio ng/Kg 193 180/193 ---ND------97.1194---ND------72.9195---ND------72.9 196 ---ND------72.9197197/200 ---ND------146198198/199 ---ND------146199198/199 ---ND------146200197/200 ---ND------146 201 ---ND------72.9202---ND------72.9203---ND------72.9 204 ---ND------72.9205---ND------72.9206---ND------72.9 207 ---ND------72.9208---ND------72.9209---ND------72.9 Page 30 of 41Report No.....10439556_1668_209_DFR Page 47 of 58 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SD008-F005 P180727A_13 Sample Analysis Results Lab Sample ID 92391723003 Congener Group Concentration ng/Kg Total MonochloroBiphenyls ND TotalDichloroBiphenyls ND Total TrichloroBiphenyls ND Total TetrachloroBiphenyls ND TotalPentachloroBiphenyls ND TotalHexachloroBiphenyls ND TotalHeptachloroBiphenyls ND Total Octachloro Biphenyls ND TotalNonachloroBiphenyls ND DecachloroBiphenyls ND TotalPCBs ND Results reported on a dry weight basis ND = Not Detected Page 31 of 41Report No.....10439556_1668_209_DFR Page 48 of 58 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Method 1668A Polychlorobiphenyl Lab Sample ID Injected ByFilename Total Amount Extracted ICAL ID CCal Filename(s) BLANK-63507 P180723B_07BAL10.7 g P180723B02 P180723B_01 MatrixExtracted Analyzed Soil/Solid (QC Matrix)07/17/2018 15:00 07/23/2018 23:24 Blank Analysis Results Dilution NA PCB Isomer RT % Recoveryng's Foundng's AddedIUPACRatio Labeled Analytes13C-2-MoCB 1 2.72 2.09.576 1.23 6213C-4-MoCB 3 3.20 2.012.427 1.14 5713C-2,2'-DiCB 4 1.33 2.012.739 1.13 5613C-4,4'-DiCB 15 1.58 2.019.903 1.39 6913C-2,2',6-TrCB 19 1.07 2.016.608 1.40 7013C-3,4,4'-TrCB 37 1.20 2.027.711 1.81 9013C-2,2',6,6'-TeCB 54 0.74 2.020.215 1.36 68 13C-3,4,4',5-TeCB 81 0.73 2.034.827 1.54 7713C-3,3',4,4'-TeCB 77 0.76 2.035.464 1.54 7713C-2,2',4,6,6'-PeCB 104 1.63 2.026.302 1.35 6813C-2,3,3',4,4'-PeCB 105 1.51 2.039.008 1.64 8213C-2,3,4,4',5-PeCB 114 1.68 2.038.320 1.62 8113C-2,3',4,4',5-PeCB 118 1.68 2.037.784 1.54 7713C-2,3',4,4',5'-PeCB 123 1.51 2.037.432 1.63 8113C-3,3',4,4',5-PeCB 126 1.54 2.042.178 1.88 9413C-2,2',4,4',6,6'-HxCB 155 1.16 2.032.328 1.28 6413C-HxCB (156/157)156/157 1.23 4.045.218 2.86 7113C-2,3',4,4',5,5'-HxCB 167 1.38 2.044.044 1.47 7413C-3,3',4,4',5,5'-HxCB 169 1.25 2.048.556 1.60 8013C-2,2',3,4',5,6,6'-HpCB 188 1.05 2.038.253 1.36 6813C-2,3,3',4,4',5,5'-HpCB 189 1.00 2.051.050 1.50 7513C-2,2',3,3',5,5',6,6'-OcCB 202 0.89 2.043.726 1.48 7413C-2,3,3',4,4',5,5',6-OcCB 205 0.93 2.053.098 1.45 7313C-2,2',3,3',4,4',5,5',6-NoCB 206 0.74 2.054.520 1.62 8113C-2,2',3,3',4,5,5',6,6'-NoCB 208 0.81 2.050.489 1.56 7813C--DeCB 209 0.73 2.055.986 1.57 78 Cleanup Standards13C-2,4,4'-TrCB 28 1.01 2.023.301 1.59 8013C-2,3,3',5,5'-PeCB 111 1.68 2.035.397 1.49 7513C-2,2',3,3',5,5',6-HpCB 178 1.09 2.041.389 1.65 82 Recovery Standards13C-2,5-DiCB 9 1.58 2.015.229 NA NA13C-2,2',5,5'-TeCB 52 0.84 2.025.280 NA NA13C-2,2',4,5,5'-PeCB 101 1.58 2.032.597 NA NA13C-2,2',3,4,4',5'-HxCB 138 1.31 2.040.970 NA NA13C-2,2',3,3',4,4',5,5'-OcCB 194 0.87 2.052.731 NA NA Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = NanogramsResultsreportedonatotalweightbasis Page 32 of 41Report No.....10439556_1668_209_DFR Page 49 of 58 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits ng/L = Nanograms per liter Resultsreported ona totalweight basis ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference Method 1668A Polychlorobiphenyl Lab Sample ID Filename BLANK-63507 P180723B_07 Blank Analysis Results Co-elutions RT ng/Kg EMLEMPCConcentration ng/KgIUPACRatio ng/Kg 1 ---ND------23.42---ND------23.43---ND------23.44---ND------23.45---ND------23.46---ND------23.47---ND------23.48---ND------23.49---ND------23.410---ND------23.411---ND------2291212/13 ---ND------46.71312/13 ---ND------46.714---ND------23.415---ND------23.416---ND------23.417---ND------23.41818/30 ---ND------46.7 19 ---ND------23.42020/28 ---ND------1212121/33 ---ND------12622---ND------88.823---ND------23.424---ND------23.425---ND------23.42626/29 ---ND------46.727---ND------23.42820/28 ---ND------1212926/29 ---ND------46.73018/30 ---ND------46.731---ND------12132---ND------23.43321/33 ---ND------12634---ND------23.435---ND------23.436---ND------23.437---ND------49.538---ND------23.439---ND------23.44040/41/71 ---ND------1404140/41/71 ---ND------14042---ND------46.74343/73 ---ND------46.7 44 44/47/65 ---ND------1404545/51 ---ND------93.5 Page 33 of 41Report No.....10439556_1668_209_DFR Page 50 of 58 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits ng/L = Nanograms per liter Resultsreported ona totalweight basis ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference Method 1668A Polychlorobiphenyl Lab Sample ID Filename BLANK-63507 P180723B_07 Blank Analysis Results Co-elutions RT ng/Kg EMLEMPCConcentration ng/KgIUPACRatio ng/Kg 46 ---ND------46.74744/47/65 ---ND------14048---ND------46.74949/69 ---ND------93.55050/53 ---ND------93.55145/51 ---ND------93.552---ND------1445350/53 ---ND------93.554---ND------46.755---ND------46.756---ND------46.757---ND------46.758---ND------46.75959/62/75 ---ND------14060---ND------46.76161/70/74/76 ---ND------1876259/62/75 ---ND------14063---ND------46.7 64 ---ND------46.76544/47/65 ---ND------14066---ND------78.567---ND------46.768---ND------46.76949/69 ---ND------93.57061/70/74/76 ---ND------1877140/41/71 ---ND------14072---ND------46.77343/73 ---ND------46.77461/70/74/76 ---ND------1877559/62/75 ---ND------1407661/70/74/76 ---ND------18777---ND------46.778---ND------46.779---ND------46.780---ND------46.781---ND------46.782---ND------46.783---ND------46.784---ND------46.78585/116/117 ---ND------1408686/87/97/108/119/125 ---ND------2808786/87/97/108/119/125 ---ND------2808888/91 ---ND------93.5 89 ---ND------46.79090/101/113 ---ND------140 Page 34 of 41Report No.....10439556_1668_209_DFR Page 51 of 58 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits ng/L = Nanograms per liter Resultsreported ona totalweight basis ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference Method 1668A Polychlorobiphenyl Lab Sample ID Filename BLANK-63507 P180723B_07 Blank Analysis Results Co-elutions RT ng/Kg EMLEMPCConcentration ng/KgIUPACRatio ng/Kg 91 88/91 ---ND------93.592---ND------46.79393/98/100/102 ---ND------18794---ND------46.795---ND------88.896---ND------46.79786/87/97/108/119/125 ---ND------2809893/98/100/102 ---ND------18799---ND------46.710093/98/100/102 ---ND------18710190/101/113 ---ND------14010293/98/100/102 ---ND------187103---ND------46.7104---ND------46.7105---ND------46.7106---ND------46.7107107/124 ---ND------93.510886/87/97/108/119/125 ---ND------280 109 ---ND------46.7110110/115 ---ND------93.5111---ND------46.7112---ND------46.711390/101/113 ---ND------140114---ND------46.7115110/115 ---ND------93.511685/116/117 ---ND------14011785/116/117 ---ND------140118---ND------59.811986/87/97/108/119/125 ---ND------280120---ND------46.7121---ND------46.7122---ND------46.7123---ND------46.7124107/124 ---ND------93.512586/87/97/108/119/125 ---ND------280126---ND------46.7127---ND------46.7128128/166 ---ND------93.5129129/138/163 ---ND------140130---ND------46.7131---ND------46.7132---ND------46.7133---ND------46.7 134 134/143 ---ND------93.5135135/151 ---ND------93.5 Page 35 of 41Report No.....10439556_1668_209_DFR Page 52 of 58 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits ng/L = Nanograms per liter Resultsreported ona totalweight basis ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference Method 1668A Polychlorobiphenyl Lab Sample ID Filename BLANK-63507 P180723B_07 Blank Analysis Results Co-elutions RT ng/Kg EMLEMPCConcentration ng/KgIUPACRatio ng/Kg 136 ---ND------46.7137---ND------46.7138129/138/163 ---ND------140139139/140 ---ND------93.5140139/140 ---ND------93.5141---ND------46.7142---ND------46.7143134/143 ---ND------93.5144---ND------46.7145---ND------46.7146---ND------46.7147147/149 ---ND------93.5148---ND------46.7149147/149 ---ND------93.5150---ND------46.7151135/151 ---ND------93.5152---ND------46.7153153/168 ---ND------93.5 154 ---ND------46.7155---ND------46.7156156/157 ---ND------93.5157156/157 ---ND------93.5158---ND------46.7159---ND------46.7160---ND------46.7161---ND------46.7162---ND------46.7163129/138/163 ---ND------140164---ND------46.7165---ND------46.7166128/166 ---ND------93.5167---ND------46.7168153/168 ---ND------93.5169---ND------46.7170---ND------46.7171171/173 ---ND------93.5172---ND------46.7173171/173 ---ND------93.5174---ND------46.7175---ND------46.7176---ND------46.7177---ND------46.7178---ND------46.7 179 ---ND------46.7180180/193 ---ND------93.5 Page 36 of 41Report No.....10439556_1668_209_DFR Page 53 of 58 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits ng/L = Nanograms per liter Resultsreported ona totalweight basis ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference Method 1668A Polychlorobiphenyl Lab Sample ID Filename BLANK-63507 P180723B_07 Blank Analysis Results Co-elutions RT ng/Kg EMLEMPCConcentration ng/KgIUPACRatio ng/Kg 181 ---ND------46.7182---ND------46.7183183/185 ---ND------93.5184---ND------46.7185183/185 ---ND------93.5186---ND------46.7187---ND------46.7188---ND------46.7189---ND------46.7190---ND------46.7191---ND------46.7192---ND------46.7193180/193 ---ND------93.5194---ND------70.1195---ND------70.1196---ND------70.1197197/200 ---ND------140198198/199 ---ND------140 199 198/199 ---ND------140200197/200 ---ND------140201---ND------70.1202---ND------70.1203---ND------70.1204---ND------70.1205---ND------70.1206---ND------70.1207---ND------70.1208---ND------70.1209---ND------70.1 Page 37 of 41Report No.....10439556_1668_209_DFR Page 54 of 58 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Method 1668A Polychlorobiphenyl Client Sample ID Filename CBLKSW P180723B_07 Blank Analysis Results Lab Sample ID BLANK-63507 Congener Group Concentration ng/Kg Total MonochloroBiphenyls ND TotalDichloroBiphenyls ND Total TrichloroBiphenyls ND Total TetrachloroBiphenyls ND TotalPentachloroBiphenyls ND TotalHexachloroBiphenyls ND TotalHeptachloroBiphenyls ND Total Octachloro Biphenyls ND TotalNonachloroBiphenyls ND DecachloroBiphenyls ND TotalPCBs ND Results reported on a total weight basis ND = Not Detected Page 38 of 41Report No.....10439556_1668_209_DFR Page 55 of 58 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Method 1668A Polychlorobiphenyls Lab Sample ID Injected By FilenameTotal Amount Extracted ICAL ID CCal Filename(s) LCS-63508P180723B_03 BAL 10.0 g P180723B02 P180723B_01 MatrixDilution Extracted Analyzed Soil/Solid (QC Matrix) 07/17/2018 15:00 07/23/2018 19:25 NA Method Blank ID BLANK-63507 Laboratory Control Spike Analysis Results PCB Spiked Found Spiked Found % RecoveryIsomer(ng)(ng) % Recovery(ng)(ng) Native Analytes Labeled Analytes 1 1.0 0.926 2.0 1.17 5893 3 1.0 0.991 2.0 1.12 569941.0 0.964 2.0 1.16 58125I151.0 0.831 2.0 1.26 6383 19 1.0 0.658 2.0 1.58 7973I 37 1.0 0.769 2.0 1.33 6677 54 1.0 0.764 2.0 1.21 6176811.0 0.931 2.0 1.30 6593771.0 0.847 2.0 1.35 6885 104 1.0 0.979 2.0 1.13 5698 105 1.0 0.984 2.0 1.44 7298 114 1.0 0.845 2.0 1.40 7092I1181.0 0.916 2.0 1.42 71921231.0 1.04 2.0 1.43 72104 126 1.0 0.963 2.0 1.58 7996 155 1.0 0.962 2.0 1.10 5596 156/157 2.0 1.95 4.0 2.68 67981671.0 0.973 2.0 1.29 64971691.0 0.925 2.0 1.62 8193 188 1.0 0.948 2.0 1.13 5695 189 1.0 0.902 2.0 1.48 7490 202 1.0 0.922 2.0 1.25 63922051.0 1.07 2.0 1.41 711072061.0 1.04 2.0 1.37 69104 208 1.0 1.01 2.0 1.32 66101 209 1.0 0.974 2.0 1.45 7297 R =Recovery outside of method 1668A control limits Nn =Result obtained from alternate analysis ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion ng = Nanograms I=Interference Page 39 of 41Report No.....10439556_1668_209_DFR Page 56 of 58 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Method 1668A Polychlorobiphenyls Lab Sample ID Injected By FilenameTotal Amount Extracted ICAL ID CCal Filename(s) LCSD-63509P180723B_04 BAL 10.1 g P180723B02 P180723B_01 MatrixDilution Extracted Analyzed Solid 07/17/2018 15:00 07/23/2018 20:25 NA Method Blank ID BLANK-63507 Laboratory Control Spike Analysis Results PCB Spiked Found Spiked Found % RecoveryIsomer(ng)(ng) % Recovery(ng)(ng) Native Analytes Labeled Analytes 1 1.0 1.04 2.0 1.18 59104 3 1.0 0.920 2.0 1.30 659241.0 1.00 2.0 1.40 70100151.0 1.04 2.0 1.47 74104 19 1.0 0.719 2.0 1.97 9872 37 1.0 0.714 2.0 1.56 8771 I 54 1.0 0.901 2.0 1.34 6790811.0 0.842 2.0 1.50 7584771.0 0.816 2.0 1.66 8382 104 1.0 1.02 2.0 1.38 69102 105 1.0 0.987 2.0 1.69 8499 114 1.0 0.953 2.0 1.61 80951181.0 0.933 2.0 1.62 81931231.0 0.940 2.0 1.61 8194 126 1.0 0.866 2.0 1.96 9887 155 1.0 0.919 2.0 1.38 6992 156/157 2.0 1.80 4.0 3.16 79901671.0 0.933 2.0 1.60 80931691.0 0.949 2.0 1.73 8695 188 1.0 1.05 2.0 1.41 71105 189 1.0 0.888 2.0 1.71 8589 202 1.0 0.972 2.0 1.64 82972051.0 1.02 2.0 1.60 801022061.0 0.987 2.0 1.63 8299 208 1.0 1.01 2.0 1.64 82101 209 1.0 1.01 2.0 1.76 88101 R =Recovery outside of method 1668A control limits Nn =Result obtained from alternate analysis ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion ng = Nanograms I=Interference Page 40 of 41Report No.....10439556_1668_209_DFR Page 57 of 58 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Client Spike 1 ID Spike 1 Filename P180723B_03 LCS-63508 PACE Charlotte Spike Recovery Relative Percent Difference (RPD) Results Spike 2 ID Spike 2 Filename P180723B_04 LCSD-63509 Method 1668A Spike 1 Spike 2 Compound %REC %REC %RPDIUPAC 2-MoCB 93 104 11.214-MoCB 99 92 7.332,2'-DiCB 125 100 22.244,4'-DiCB 83 104 22.5152,2',6-TrCB 73 72 1.4193,4,4'-TrCB 77 71 8.1372,2',6,6'-TeCB 76 90 16.9543,3',4,4'-TeCB 85 82 3.6773,4,4',5-TeCB 93 84 10.2812,2',4,6,6'-PeCB 98 102 4.01042,3,3',4,4'-PeCB 98 99 1.01052,3,4,4',5-PeCB 92 95 3.21142,3',4,4',5-PeCB 92 93 1.11182,3',4,4',5'-PeCB 104 94 10.11233,3',4,4',5-PeCB 96 87 9.81262,2',4,4',6,6'-HxCB 96 92 4.3155(156/157)98 90 8.5156/1572,3',4,4',5,5'-HxCB 97 93 4.21673,3',4,4',5,5'-HxCB 93 95 2.11692,2',3,4',5,6,6'-HpCB 95 105 10.01882,3,3',4,4',5,5'-HpCB 90 89 1.11892,2',3,3',5,5',6,6'-OcCB 92 97 5.32022,3,3',4,4',5,5',6-OcCB 107 102 4.8205 2,2',3,3',4,4',5,5',6-NoCB 104 99 4.92062,2',3,3',4,5,5',6,6'-NoCB 101 101 0.0208Decachlorobiphenyl971014.0209 %REC =Percent Recovered RPD =The difference between the two values dividedby the meanvalue Page 41 of 41Report No.....10439556_1668_209_DFR Page 58 of 58 #=CL# July 26, 2018 LIMS USE: FR - MICHAEL WORDEN LIMS OBJECT ID: 92391738 92391738 Project: Pace Project No.: RE: Michael W. Worden Environeering, Inc. 16100 Cairnway Suite 320 Houston, TX 77084 Little Mountain Creek SW Dear Michael Worden: Enclosed are the analytical results for sample(s) received by the laboratory on July 12, 2018. The results relate only to the samples included in this report. Results reported herein conform to the most current, applicable TNI/NELAC standards and the laboratory's Quality Assurance Manual, where applicable, unless otherwise noted in the body of the report. If you have any questions concerning this report, please feel free to contact me. Sincerely, Nicole Gasiorowski nicole.gasiorowski@pacelabs.com Project Manager (704)875-9092 Enclosures REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 1 of 79 #=CP# CERTIFICATIONS Pace Project No.: Project: 92391738 Little Mountain Creek SW Charlotte Certification IDs 9800 Kincey Ave. Ste 100, Huntersville, NC 28078 Louisiana/NELAP Certification # LA170028 North Carolina Drinking Water Certification #: 37706 North Carolina Field Services Certification #: 5342 North Carolina Wastewater Certification #: 12 South Carolina Certification #: 99006001 Florida/NELAP Certification #: E87627 Kentucky UST Certification #: 84 Virginia/VELAP Certification #: 460221 Asheville Certification IDs 2225 Riverside Drive, Asheville, NC 28804 Florida/NELAP Certification #: E87648 Massachusetts Certification #: M-NC030 North Carolina Drinking Water Certification #: 37712 North Carolina Wastewater Certification #: 40 South Carolina Certification #: 99030001 Virginia/VELAP Certification #: 460222 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 2 of 79 #=SS# SAMPLE SUMMARY Pace Project No.: Project: 92391738 Little Mountain Creek SW Lab ID Sample ID Matrix Date Collected Date Received 92391738001 ABL-SW008-F005 Water 07/12/18 00:00 07/12/18 12:30 92391738002 ABL-SW008-D005 Water 07/12/18 00:00 07/12/18 12:30 92391738003 ABL-SW009-F005 Water 07/12/18 00:00 07/12/18 12:30 92391738004 ABL-SW010-F005 Water 07/12/18 00:00 07/12/18 12:30 92391738005 ABL-SW011-F005 Water 07/12/18 00:00 07/12/18 12:30 92391738006 ABL-SW012-F005 Water 07/12/18 00:00 07/12/18 12:30 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 3 of 79 #=SA# SAMPLE ANALYTE COUNT Pace Project No.: Project: 92391738 Little Mountain Creek SW Lab ID Sample ID Method Analytes Reported LaboratoryAnalysts 92391738001 ABL-SW008-F005 EPA 8082A 8 PASI-CNU1 EPA 200.7 Rev 4.4 1994 3 PASI-ASH1 EPA 300.0 Rev 2.1 1993 1 PASI-ACDC EPA 9012B 1 PASI-ACJH1 92391738002 ABL-SW008-D005 EPA 8082A 8 PASI-CNU1 EPA 200.7 Rev 4.4 1994 3 PASI-ASH1 EPA 300.0 Rev 2.1 1993 1 PASI-ACDC EPA 9012B 1 PASI-ACJH1 92391738003 ABL-SW009-F005 EPA 8082A 8 PASI-CNU1 EPA 200.7 Rev 4.4 1994 3 PASI-ASH1 EPA 300.0 Rev 2.1 1993 1 PASI-ACDC EPA 9012B 1 PASI-ACJH1 92391738004 ABL-SW010-F005 EPA 8082A 8 PASI-CNU1 EPA 200.7 Rev 4.4 1994 3 PASI-ASH1 EPA 300.0 Rev 2.1 1993 1 PASI-ACDC EPA 9012B 1 PASI-ACJH1 92391738005 ABL-SW011-F005 EPA 8082A 8 PASI-CNU1 EPA 200.7 Rev 4.4 1994 3 PASI-ASH1 EPA 300.0 Rev 2.1 1993 1 PASI-ACDC EPA 9012B 1 PASI-ACJH1 92391738006 ABL-SW012-F005 EPA 8082A 8 PASI-CNU1 EPA 200.7 Rev 4.4 1994 3 PASI-ASH1 EPA 300.0 Rev 2.1 1993 1 PASI-ACDC EPA 9012B 1 PASI-ACJH1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 4 of 79 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92391738 Little Mountain Creek SW Sample:ABL-SW008-F005 Lab ID:92391738001 Collected:07/12/18 00:00 Received:07/12/18 12:30 Matrix:Water Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 8082A Preparation Method: EPA 3510C8082 GCS PCB RVE PCB-1016 (Aroclor 1016)ND ug/L 07/16/18 20:21 12674-11-207/12/18 19:400.42 0.42 1 PCB-1221 (Aroclor 1221)ND ug/L 07/16/18 20:21 11104-28-207/12/18 19:400.42 0.42 1 PCB-1232 (Aroclor 1232)ND ug/L 07/16/18 20:21 11141-16-507/12/18 19:400.42 0.42 1 PCB-1242 (Aroclor 1242)ND ug/L 07/16/18 20:21 53469-21-907/12/18 19:400.42 0.42 1 PCB-1248 (Aroclor 1248)ND ug/L 07/16/18 20:21 12672-29-607/12/18 19:400.42 0.42 1 PCB-1254 (Aroclor 1254)ND ug/L 07/16/18 20:21 11097-69-107/12/18 19:400.42 0.42 1 PCB-1260 (Aroclor 1260)ND ug/L 07/16/18 20:21 11096-82-507/12/18 19:400.42 0.42 1 Surrogates Decachlorobiphenyl (S)55 %07/16/18 20:21 2051-24-307/12/18 19:4010-132 1 Analytical Method: EPA 200.7 Rev 4.4 1994 Preparation Method: EPA 200.7 Rev 4.4 1994200.7 MET ICP Arsenic ND ug/L 07/14/18 06:16 7440-38-207/13/18 05:2010.0 5.0 1 Lead 2.6J ug/L 07/14/18 06:16 7439-92-107/13/18 05:205.0 2.5 1 Hardness, Total(SM 2340B)37800 ug/L 07/14/18 06:1607/13/18 05:206626621 Analytical Method: EPA 300.0 Rev 2.1 1993300.0 IC Anions 28 Days Fluoride 0.088J mg/L 07/21/18 00:42 16984-48-80.10 0.050 1 Analytical Method: EPA 9012B Preparation Method: EPA 9012B9012B Cyanide, Total Cyanide ND mg/L 07/17/18 15:35 57-12-507/17/18 11:150.0080 0.0040 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 07/26/2018 04:08 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 5 of 79 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92391738 Little Mountain Creek SW Sample:ABL-SW008-D005 Lab ID:92391738002 Collected:07/12/18 00:00 Received:07/12/18 12:30 Matrix:Water Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 8082A Preparation Method: EPA 3510C8082 GCS PCB RVE PCB-1016 (Aroclor 1016)ND ug/L 07/16/18 20:34 12674-11-207/12/18 19:400.42 0.42 1 PCB-1221 (Aroclor 1221)ND ug/L 07/16/18 20:34 11104-28-207/12/18 19:400.42 0.42 1 PCB-1232 (Aroclor 1232)ND ug/L 07/16/18 20:34 11141-16-507/12/18 19:400.42 0.42 1 PCB-1242 (Aroclor 1242)ND ug/L 07/16/18 20:34 53469-21-907/12/18 19:400.42 0.42 1 PCB-1248 (Aroclor 1248)ND ug/L 07/16/18 20:34 12672-29-607/12/18 19:400.42 0.42 1 PCB-1254 (Aroclor 1254)ND ug/L 07/16/18 20:34 11097-69-107/12/18 19:400.42 0.42 1 PCB-1260 (Aroclor 1260)ND ug/L 07/16/18 20:34 11096-82-507/12/18 19:400.42 0.42 1 Surrogates Decachlorobiphenyl (S)57 %07/16/18 20:34 2051-24-307/12/18 19:4010-132 1 Analytical Method: EPA 200.7 Rev 4.4 1994 Preparation Method: EPA 200.7 Rev 4.4 1994200.7 MET ICP Arsenic ND ug/L 07/14/18 06:19 7440-38-207/13/18 05:2010.0 5.0 1 Lead ND ug/L 07/14/18 06:19 7439-92-107/13/18 05:205.0 2.5 1 Hardness, Total(SM 2340B)38500 ug/L 07/14/18 06:1907/13/18 05:206626621 Analytical Method: EPA 300.0 Rev 2.1 1993300.0 IC Anions 28 Days Fluoride 0.087J mg/L 07/21/18 02:08 16984-48-80.10 0.050 1 Analytical Method: EPA 9012B Preparation Method: EPA 9012B9012B Cyanide, Total Cyanide ND mg/L 07/17/18 15:38 57-12-507/17/18 11:150.0080 0.0040 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 07/26/2018 04:08 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 6 of 79 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92391738 Little Mountain Creek SW Sample:ABL-SW009-F005 Lab ID:92391738003 Collected:07/12/18 00:00 Received:07/12/18 12:30 Matrix:Water Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 8082A Preparation Method: EPA 3510C8082 GCS PCB RVE PCB-1016 (Aroclor 1016)ND ug/L 07/16/18 20:47 12674-11-207/12/18 19:400.42 0.42 1 PCB-1221 (Aroclor 1221)ND ug/L 07/16/18 20:47 11104-28-207/12/18 19:400.42 0.42 1 PCB-1232 (Aroclor 1232)ND ug/L 07/16/18 20:47 11141-16-507/12/18 19:400.42 0.42 1 PCB-1242 (Aroclor 1242)ND ug/L 07/16/18 20:47 53469-21-907/12/18 19:400.42 0.42 1 PCB-1248 (Aroclor 1248)ND ug/L 07/16/18 20:47 12672-29-607/12/18 19:400.42 0.42 1 PCB-1254 (Aroclor 1254)ND ug/L 07/16/18 20:47 11097-69-107/12/18 19:400.42 0.42 1 PCB-1260 (Aroclor 1260)ND ug/L 07/16/18 20:47 11096-82-507/12/18 19:400.42 0.42 1 Surrogates Decachlorobiphenyl (S)62 %07/16/18 20:47 2051-24-307/12/18 19:4010-132 1 Analytical Method: EPA 200.7 Rev 4.4 1994 Preparation Method: EPA 200.7 Rev 4.4 1994200.7 MET ICP Arsenic ND ug/L 07/14/18 06:22 7440-38-207/13/18 05:2010.0 5.0 1 Lead ND ug/L 07/14/18 06:22 7439-92-107/13/18 05:205.0 2.5 1 Hardness, Total(SM 2340B)36600 ug/L 07/14/18 06:2207/13/18 05:206626621 Analytical Method: EPA 300.0 Rev 2.1 1993300.0 IC Anions 28 Days Fluoride 0.078J mg/L 07/21/18 02:25 16984-48-80.10 0.050 1 Analytical Method: EPA 9012B Preparation Method: EPA 9012B9012B Cyanide, Total Cyanide ND mg/L 07/17/18 15:39 57-12-507/17/18 11:150.0080 0.0040 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 07/26/2018 04:08 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 7 of 79 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92391738 Little Mountain Creek SW Sample:ABL-SW010-F005 Lab ID:92391738004 Collected:07/12/18 00:00 Received:07/12/18 12:30 Matrix:Water Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 8082A Preparation Method: EPA 3510C8082 GCS PCB RVE PCB-1016 (Aroclor 1016)ND ug/L 07/16/18 21:00 12674-11-207/12/18 19:400.42 0.42 1 PCB-1221 (Aroclor 1221)ND ug/L 07/16/18 21:00 11104-28-207/12/18 19:400.42 0.42 1 PCB-1232 (Aroclor 1232)ND ug/L 07/16/18 21:00 11141-16-507/12/18 19:400.42 0.42 1 PCB-1242 (Aroclor 1242)ND ug/L 07/16/18 21:00 53469-21-907/12/18 19:400.42 0.42 1 PCB-1248 (Aroclor 1248)ND ug/L 07/16/18 21:00 12672-29-607/12/18 19:400.42 0.42 1 PCB-1254 (Aroclor 1254)ND ug/L 07/16/18 21:00 11097-69-107/12/18 19:400.42 0.42 1 PCB-1260 (Aroclor 1260)ND ug/L 07/16/18 21:00 11096-82-507/12/18 19:400.42 0.42 1 Surrogates Decachlorobiphenyl (S)51 %07/16/18 21:00 2051-24-307/12/18 19:4010-132 1 Analytical Method: EPA 200.7 Rev 4.4 1994 Preparation Method: EPA 200.7 Rev 4.4 1994200.7 MET ICP Arsenic ND ug/L 07/14/18 06:25 7440-38-207/13/18 05:2010.0 5.0 1 Lead ND ug/L 07/14/18 06:25 7439-92-107/13/18 05:205.0 2.5 1 Hardness, Total(SM 2340B)36000 ug/L 07/14/18 06:2507/13/18 05:206626621 Analytical Method: EPA 300.0 Rev 2.1 1993300.0 IC Anions 28 Days Fluoride 0.074J mg/L 07/21/18 02:42 16984-48-80.10 0.050 1 Analytical Method: EPA 9012B Preparation Method: EPA 9012B9012B Cyanide, Total Cyanide ND mg/L 07/17/18 15:39 57-12-507/17/18 11:150.0080 0.0040 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 07/26/2018 04:08 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 8 of 79 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92391738 Little Mountain Creek SW Sample:ABL-SW011-F005 Lab ID:92391738005 Collected:07/12/18 00:00 Received:07/12/18 12:30 Matrix:Water Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 8082A Preparation Method: EPA 3510C8082 GCS PCB RVE PCB-1016 (Aroclor 1016)ND ug/L 07/16/18 21:13 12674-11-207/12/18 19:400.42 0.42 1 PCB-1221 (Aroclor 1221)ND ug/L 07/16/18 21:13 11104-28-207/12/18 19:400.42 0.42 1 PCB-1232 (Aroclor 1232)ND ug/L 07/16/18 21:13 11141-16-507/12/18 19:400.42 0.42 1 PCB-1242 (Aroclor 1242)ND ug/L 07/16/18 21:13 53469-21-907/12/18 19:400.42 0.42 1 PCB-1248 (Aroclor 1248)ND ug/L 07/16/18 21:13 12672-29-607/12/18 19:400.42 0.42 1 PCB-1254 (Aroclor 1254)ND ug/L 07/16/18 21:13 11097-69-107/12/18 19:400.42 0.42 1 PCB-1260 (Aroclor 1260)ND ug/L 07/16/18 21:13 11096-82-507/12/18 19:400.42 0.42 1 Surrogates Decachlorobiphenyl (S)47 %07/16/18 21:13 2051-24-307/12/18 19:4010-132 1 Analytical Method: EPA 200.7 Rev 4.4 1994 Preparation Method: EPA 200.7 Rev 4.4 1994200.7 MET ICP Arsenic ND ug/L 07/14/18 06:28 7440-38-207/13/18 05:2010.0 5.0 1 Lead ND ug/L 07/14/18 06:28 7439-92-107/13/18 05:205.0 2.5 1 Hardness, Total(SM 2340B)37300 ug/L 07/14/18 06:2807/13/18 05:206626621 Analytical Method: EPA 300.0 Rev 2.1 1993300.0 IC Anions 28 Days Fluoride 0.078J mg/L 07/21/18 02:59 16984-48-80.10 0.050 1 Analytical Method: EPA 9012B Preparation Method: EPA 9012B9012B Cyanide, Total Cyanide ND mg/L 07/17/18 15:40 57-12-507/17/18 11:150.0080 0.0040 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 07/26/2018 04:08 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 9 of 79 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92391738 Little Mountain Creek SW Sample:ABL-SW012-F005 Lab ID:92391738006 Collected:07/12/18 00:00 Received:07/12/18 12:30 Matrix:Water Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 8082A Preparation Method: EPA 3510C8082 GCS PCB RVE PCB-1016 (Aroclor 1016)ND ug/L 07/16/18 21:25 12674-11-207/12/18 19:400.42 0.42 1 PCB-1221 (Aroclor 1221)ND ug/L 07/16/18 21:25 11104-28-207/12/18 19:400.42 0.42 1 PCB-1232 (Aroclor 1232)ND ug/L 07/16/18 21:25 11141-16-507/12/18 19:400.42 0.42 1 PCB-1242 (Aroclor 1242)ND ug/L 07/16/18 21:25 53469-21-907/12/18 19:400.42 0.42 1 PCB-1248 (Aroclor 1248)ND ug/L 07/16/18 21:25 12672-29-607/12/18 19:400.42 0.42 1 PCB-1254 (Aroclor 1254)ND ug/L 07/16/18 21:25 11097-69-107/12/18 19:400.42 0.42 1 PCB-1260 (Aroclor 1260)ND ug/L 07/16/18 21:25 11096-82-507/12/18 19:400.42 0.42 1 Surrogates Decachlorobiphenyl (S)59 %07/16/18 21:25 2051-24-307/12/18 19:4010-132 1 Analytical Method: EPA 200.7 Rev 4.4 1994 Preparation Method: EPA 200.7 Rev 4.4 1994200.7 MET ICP Arsenic ND ug/L 07/14/18 06:31 7440-38-207/13/18 05:2010.0 5.0 1 Lead ND ug/L 07/14/18 06:31 7439-92-107/13/18 05:205.0 2.5 1 Hardness, Total(SM 2340B)39200 ug/L 07/14/18 06:3107/13/18 05:206626621 Analytical Method: EPA 300.0 Rev 2.1 1993300.0 IC Anions 28 Days Fluoride 0.082J mg/L 07/21/18 03:16 16984-48-80.10 0.050 1 Analytical Method: EPA 9012B Preparation Method: EPA 9012B9012B Cyanide, Total Cyanide ND mg/L 07/17/18 15:41 57-12-507/17/18 11:150.0080 0.0040 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 07/26/2018 04:08 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 10 of 79 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92391738 Little Mountain Creek SW Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 418970 EPA 200.7 Rev 4.4 1994 EPA 200.7 Rev 4.4 1994 200.7 MET Associated Lab Samples:92391738001, 92391738002, 92391738003, 92391738004, 92391738005, 92391738006 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:2322463 Associated Lab Samples:92391738001, 92391738002, 92391738003, 92391738004, 92391738005, 92391738006 Matrix:Water AnalyzedMDL Arsenic ug/L ND 10.0 07/14/18 05:445.0 Hardness, Total(SM 2340B)ug/L ND 662 07/14/18 05:44662 Lead ug/L ND 5.0 07/14/18 05:442.5 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 2322464LABORATORY CONTROL SAMPLE: LCSSpike Arsenic ug/L 434500 87 85-115 Hardness, Total(SM 2340B)ug/L 31800 Lead ug/L 449500 90 85-115 Parameter Units MS Result % Rec Limits Qual% RecConc. 2322465MATRIX SPIKE & MATRIX SPIKE DUPLICATE: MSSpike Result 92391732001 2322466 MSD Result MSD % Rec RPD RPD Max MSDMS Spike Conc. Arsenic ug/L 500 91 70-13090 1 20500ND456451 Hardness, Total(SM 2340B)ug/L 0 20393007240072100 Lead ug/L 500 90 70-13090 0 20500ND450448 Parameter Units MS Result % Rec Limits Qual% RecConc. 2322467MATRIX SPIKE & MATRIX SPIKE DUPLICATE: MSSpike Result 92391750001 2322468 MSD Result MSD % Rec RPD RPD Max MSDMS Spike Conc. Arsenic ug/L 500 93 70-13094 1 20500ND464469 Hardness, Total(SM 2340B)ug/L 1 20259005830058700 Lead ug/L 500 90 70-13090 0 20500ND450451 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 07/26/2018 04:08 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 11 of 79 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92391738 Little Mountain Creek SW Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 418714 EPA 3510C EPA 8082A 8082 GCS PCB Associated Lab Samples:92391738001, 92391738002, 92391738003, 92391738004, 92391738005, 92391738006 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:2321052 Associated Lab Samples:92391738001, 92391738002, 92391738003, 92391738004, 92391738005, 92391738006 Matrix:Water AnalyzedMDL PCB-1016 (Aroclor 1016)ug/L ND 0.50 07/16/18 23:330.50 PCB-1221 (Aroclor 1221)ug/L ND 0.50 07/16/18 23:330.50 PCB-1232 (Aroclor 1232)ug/L ND 0.50 07/16/18 23:330.50 PCB-1242 (Aroclor 1242)ug/L ND 0.50 07/16/18 23:330.50 PCB-1248 (Aroclor 1248)ug/L ND 0.50 07/16/18 23:330.50 PCB-1254 (Aroclor 1254)ug/L ND 0.50 07/16/18 23:330.50 PCB-1260 (Aroclor 1260)ug/L ND 0.50 07/16/18 23:330.50 Decachlorobiphenyl (S)%73 10-132 07/16/18 23:33 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 2321053LABORATORY CONTROL SAMPLE & LCSD: LCSSpike LCSD % Rec RPD Max RPD LCSD Result 2321054 PCB-1016 (Aroclor 1016)ug/L 3.65 72 50-150683.4 6 30 PCB-1260 (Aroclor 1260)ug/L 4.05 80 50-150743.7 9 30 Decachlorobiphenyl (S)%76 10-13281 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 07/26/2018 04:08 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 12 of 79 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92391738 Little Mountain Creek SW Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 420255 EPA 300.0 Rev 2.1 1993 EPA 300.0 Rev 2.1 1993 300.0 IC Anions Associated Lab Samples:92391738001, 92391738002, 92391738003, 92391738004, 92391738005, 92391738006 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:2328345 Associated Lab Samples:92391738001, 92391738002, 92391738003, 92391738004, 92391738005, 92391738006 Matrix:Water AnalyzedMDL Fluoride mg/L ND 0.10 07/21/18 00:080.050 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 2328346LABORATORY CONTROL SAMPLE: LCSSpike Fluoride mg/L 2.62.5 103 90-110 Parameter Units MS Result % Rec Limits Qual% RecConc. 2328347MATRIX SPIKE & MATRIX SPIKE DUPLICATE: MSSpike Result 92391738001 2328348 MSD Result MSD % Rec RPD RPD Max MSDMS Spike Conc. Fluoride mg/L 2.5 96 90-11096 0 102.50.088J 2.5 2.5 Parameter Units MS Result % Rec Limits Qual% RecConc. 2328349MATRIX SPIKE & MATRIX SPIKE DUPLICATE: MSSpike Result 92392497005 2328350 MSD Result MSD % Rec RPD RPD Max MSDMS Spike Conc. Fluoride mg/L 2.5 96 90-11097 1 102.50.14 2.5 2.6 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 07/26/2018 04:08 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 13 of 79 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92391738 Little Mountain Creek SW Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 419425 EPA 9012B EPA 9012B EPA 9012B Cyanide Associated Lab Samples:92391738001, 92391738002, 92391738003, 92391738004, 92391738005, 92391738006 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:2324546 Associated Lab Samples:92391738001, 92391738002, 92391738003, 92391738004, 92391738005, 92391738006 Matrix:Water AnalyzedMDL Cyanide mg/L ND 0.0080 07/17/18 15:180.0040 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 2324547LABORATORY CONTROL SAMPLE: LCSSpike Cyanide mg/L 0.092.1 92 80-120 Parameter Units MS Result % Rec Limits Qual% RecConc. 2324548MATRIX SPIKE & MATRIX SPIKE DUPLICATE: MSSpike Result 92391628001 2324549 MSD Result MSD % Rec RPD RPD Max MSDMS Spike Conc. Cyanide mg/L .1 87 75-12590 2 20.10.064 0.15 0.15 Parameter Units MS Result % Rec Limits Qual% RecConc. 2324550MATRIX SPIKE & MATRIX SPIKE DUPLICATE: MSSpike Result 92391634008 2324551 MSD Result MSD % Rec RPD RPD Max MSDMS Spike Conc. Cyanide mg/L .1 95 75-12592 3 20.1ND 0.095 0.092 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 07/26/2018 04:08 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 14 of 79 #=QL# QUALIFIERS Pace Project No.: Project: 92391738 Little Mountain Creek SW DEFINITIONS DF - Dilution Factor, if reported, represents the factor applied to the reported data due to dilution of the sample aliquot. ND - Not Detected at or above adjusted reporting limit. TNTC - Too Numerous To Count J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit. MDL - Adjusted Method Detection Limit. PQL - Practical Quantitation Limit. RL - Reporting Limit - The lowest concentration value that meets project requirements for quantitative data with known precision and bias for a specific analyte in a specific matrix. S - Surrogate 1,2-Diphenylhydrazine decomposes to and cannot be separated from Azobenzene using Method 8270. The result for each analyte is a combined concentration. Consistent with EPA guidelines, unrounded data are displayed and have been used to calculate % recovery and RPD values. LCS(D) - Laboratory Control Sample (Duplicate) MS(D) - Matrix Spike (Duplicate) DUP - Sample Duplicate RPD - Relative Percent Difference NC - Not Calculable. SG - Silica Gel - Clean-Up U - Indicates the compound was analyzed for, but not detected. Acid preservation may not be appropriate for 2 Chloroethylvinyl ether. A separate vial preserved to a pH of 4-5 is recommended in SW846 Chapter 4 for the analysis of Acrolein and Acrylonitrile by EPAMethod 8260. N-Nitrosodiphenylamine decomposes and cannot be separated from Diphenylamine using Method 8270. The result reported for each analyte is a combined concentration. Pace Analytical is TNI accredited. Contact your Pace PM for the current list of accredited analytes. TNI - The NELAC Institute. LABORATORIES Pace Analytical Services - AshevillePASI-A Pace Analytical Services - CharlottePASI-C REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 07/26/2018 04:08 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 15 of 79 #=CR# QUALITY CONTROL DATA CROSS REFERENCE TABLE Pace Project No.: Project: 92391738 Little Mountain Creek SW Lab ID Sample ID QC Batch Method QC Batch Analytical Method Analytical Batch 92391738001 418714 419331ABL-SW008-F005 EPA 3510C EPA 8082A 92391738002 418714 419331ABL-SW008-D005 EPA 3510C EPA 8082A 92391738003 418714 419331ABL-SW009-F005 EPA 3510C EPA 8082A 92391738004 418714 419331ABL-SW010-F005 EPA 3510C EPA 8082A 92391738005 418714 419331ABL-SW011-F005 EPA 3510C EPA 8082A 92391738006 418714 419331ABL-SW012-F005 EPA 3510C EPA 8082A 92391738001 418970 419048ABL-SW008-F005 EPA 200.7 Rev 4.4 1994 EPA 200.7 Rev 4.4 1994 92391738002 418970 419048ABL-SW008-D005 EPA 200.7 Rev 4.4 1994 EPA 200.7 Rev 4.4 1994 92391738003 418970 419048ABL-SW009-F005 EPA 200.7 Rev 4.4 1994 EPA 200.7 Rev 4.4 1994 92391738004 418970 419048ABL-SW010-F005 EPA 200.7 Rev 4.4 1994 EPA 200.7 Rev 4.4 1994 92391738005 418970 419048ABL-SW011-F005 EPA 200.7 Rev 4.4 1994 EPA 200.7 Rev 4.4 1994 92391738006 418970 419048ABL-SW012-F005 EPA 200.7 Rev 4.4 1994 EPA 200.7 Rev 4.4 1994 92391738001 420255ABL-SW008-F005 EPA 300.0 Rev 2.1 1993 92391738002 420255ABL-SW008-D005 EPA 300.0 Rev 2.1 1993 92391738003 420255ABL-SW009-F005 EPA 300.0 Rev 2.1 1993 92391738004 420255ABL-SW010-F005 EPA 300.0 Rev 2.1 1993 92391738005 420255ABL-SW011-F005 EPA 300.0 Rev 2.1 1993 92391738006 420255ABL-SW012-F005 EPA 300.0 Rev 2.1 1993 92391738001 419425 419520ABL-SW008-F005 EPA 9012B EPA 9012B 92391738002 419425 419520ABL-SW008-D005 EPA 9012B EPA 9012B 92391738003 419425 419520ABL-SW009-F005 EPA 9012B EPA 9012B 92391738004 419425 419520ABL-SW010-F005 EPA 9012B EPA 9012B 92391738005 419425 419520ABL-SW011-F005 EPA 9012B EPA 9012B 92391738006 419425 419520ABL-SW012-F005 EPA 9012B EPA 9012B REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 07/26/2018 04:08 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 16 of 79 Page 17 of 79 Page 18 of 79 Page 19 of 79 Thisreportshouldnotbereproduced,exceptinfull, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Theresultsrelateonlytothesamplesincludedinthisreport. Report of Laboratory Analysis www.pacelabs.com Pace Analytical Services,Inc. 1700 Elm Street Minneapolis, MN 55414 Phone: 612.607.1700 Fax: 612.607.6444 Client - Charlotte PACE Charlotte 9800 Kincey Ave. Huntersville NC 28078 REPORT OF LABORATORY ANALYSIS FOR PCBs This report has been reviewed by: Invoicing & Reporting Options: Report Information: Report Prepared Date: July 25, 2018 Pace Project #: 10439554 Sample Receipt Date: 07/14/2018 Client Project #: 92391738 Alcoa-Badin Works ( Client Sub PO #: N/A The report provided has been invoiced as a Level 2 PCB Report. If an upgrade of this report package is requested, an additional charge may be applied. Please review the attached invoice for accuracy and forward anyquestions toNathan Boberg,your Pace Project Manager. State Cert #: 27700 Report Prepared for: Page 1 of 60Report No.....10439554_1668_209_DFR July 26, 2018 Nathan Boberg, Project Manager (612) 607-6444 (fax) nathan.boberg@pacelabs.com Page 20 of 79 Pace Analytical Services,Inc. 1700 Elm Street Minneapolis, MN 55414 Phone: 612.607.1700 Fax: 612.607.6444 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. This report presents the results from the analyses performed on six samples submitted by a representative of Pace Analytical - NC. The samples were analyzed for the presence or absence of polychlorinated biphenyl (PCB) congeners using USEPA Method 1668A. Reporting limits were set to 0.25-0.75 parts-per-trillion and were adjusted for the amount of sample extracted. The dilution level noted on the data tables is being adjusted to allow the correct data flags to populate the electronic deliverables as well as the data tables. Samples and MDL extracts were analyzed at elevated volumes. That volume is being treated as a 1x dilution for calculation purposes, with larger dilutions being factored from that volume. The standard reporting limits were not adjusted since the limits remained within the calibration range even after dilutions were applied. The recoveries of the isotopically-labeled PCB internal standards in the sample extracts ranged from 37-97%. All of the labeled standard recoveries obtained for this project were within the target ranges specified in Method 1668A. Since the quantification of the native congeners was based on isotope dilution and internal standard methodology, the data were automatically corrected for variation in recovery and accurate values were obtained. Incorrect isotope ratios were obtained for selected PCB congeners. The affected congeners were flagged "I" on the results table. A laboratory method blank was prepared and analyzed with the sample batch as part of our routine quality control procedures. The results show the blank to be free of PCB congeners at the reporting limits. This indicates that the sample preparation procedures did not significantly contribute to the PCB content of the sample material. Laboratory spike samples were also prepared with the sample batch using reference material that had been fortified with native standards. The results show that the spiked native compounds were recovered at 81-113%, with relative percent differences of 0.0-14.9%. These values were within method limits. Matrix spikes were not extracted with this sample batch. DISCUSSION Page 2 of 60Report No.....10439554_1668_209_DFR Page 21 of 79 REPORT OFLABORATORY ANALYSIS This report shallnot bereproduced,exceptin full, withoutthe written consentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Report No.....10439554 Minnesota Laboratory Certifications Authority Certificate #Authority Certificate # A2LA 2926.01 Mississippi MN00064 Alabama 40770 Montana CERT0092 Alaska MN00064 Nebraska NE-OS-18-06 Alaska UST-078 Nevada MN00064 Arizona AZ0014 New Jersey (NE MN002 Arkansas 88-0680 New York (NEL 11647 CNMI Saipan MP0003 New hampshire 2081 California MN00064 North Carolina 27700 Colorado MN00064 North Carolina 530 Connecticut PH-0256 North Dakota R-036 EPA Region 8 8TMS-L Ohio 41244 Florida (NELAP E87605 Ohio VAP CL101 Georgia (EDP)959 Oklahoma 9507 Guam EPA 959 Oregon (ELAP)MN200001 Hawaii MN00064 Oregon (OREL MN300001 Idaho MN00064 Pennsylvania 68-00563 Illinois 200011 Puerto Rico MN00064 Indiana C-MN-01 South Carolina 74003001 Iowa 368 Tennessee TN02818 Kansas E-10167 Texas T104704192 Kentucky 90062 Utah (NELAP)MN00064 Louisiana 03086 Virginia 460163 Louisiana MN00064 Washington C486 Maine MN00064 West Virginia #9952C Maryland 322 West Virginia D 382 Michigan 9909 Wisconsin 999407970 Minnesota 027-053-137 Wyoming 8TMS-L Page 3 of 60Report No.....10439554_1668_209_DFR Page 22 of 79 Appendix A Sample Management Pace Analytical Services, Inc.Page 4 of 60Report No.....10439554_1668_209_DFR Page 23 of 79 Page 5 of 60Report No.....10439554_1668_209_DFR Page 24 of 79 7/16/18 Page 6 of 60Report No.....10439554_1668_209_DFR Page 25 of 79 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Report No.....10439554 Reporting Flags A = B = C = D = E = I = J = L = Nn = P = R = S = U = V = X = Y = * = Reporting Limit based on signal to noise Less than 10x higher than method blank level Result obtained from confirmation analysis Result obtained from analysis of diluted sample Exceeds calibration range Interferencepresent Estimated value Suppressive interference,analyte may be biased low Value obtained from additional analysis PCDEInterference Recovery outside target range Peak saturated Analyte not detected Result verified by confirmation analysis %DExceeds limits Calculated using average of daily RFs SeeDiscussion Page 7 of 60Report No.....10439554_1668_209_DFR Page 26 of 79 Appendix B Sample Analysis Summary Pace Analytical Services, Inc.Page 8 of 60Report No.....10439554_1668_209_DFR Page 27 of 79 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Client - PACE Charlotte Client's Sample ID Lab Sample ID Filename Injected ByTotal Amount Extracted% Moisture Dry Weight Extracted ICAL ID CCal Filename(s)Method Blank ID BLANK-63512P180721B_01 P180721B02 NA NA921 mLBAL P180721B_08 92391738001 ABL-SW008-F005 MatrixDilution Collected Received ExtractedAnalyzed 07/22/2018 00:5307/17/2018 13:15 07/14/2018 09:30 07/12/2018 NAWater Method 1668A Polychlorobiphenyl Sample Analysis Results PCB Isomer RT % Recoveryng's Foundng's AddedIUPACRatio LabeledAnalytes13C-2-MoCB 1 3.23 2.09.599 0.779 3913C-4-MoCB 3 2.72 2.012.427 0.910 4613C-2,2'-DiCB 4 1.50 2.012.739 0.835 4213C-4,4'-DiCB 15 1.60 2.019.878 1.02 5113C-2,2',6-TrCB 19 1.13 2.016.559 0.936 4713C-3,4,4'-TrCB 37 1.15 2.027.693 1.11 5513C-2,2',6,6'-TeCB 54 0.84 2.020.198 0.770 3813C-3,4,4',5-TeCB 81 0.86 2.034.808 1.21 6113C-3,3',4,4'-TeCB 77 0.79 2.035.429 1.15 5813C-2,2',4,6,6'-PeCB 104 1.54 2.026.301 0.865 4313C-2,3,3',4,4'-PeCB 105 1.71 2.039.006 1.42 7113C-2,3,4,4',5-PeCB 114 1.53 2.038.335 1.36 6813C-2,3',4,4',5-PeCB 118 1.62 2.037.782 1.32 6613C-2,3',4,4',5'-PeCB 123 1.52 2.037.430 1.40 7013C-3,3',4,4',5-PeCB 126 1.65 2.042.192 1.46 7313C-2,2',4,4',6,6'-HxCB 155 1.25 2.032.327 0.893 4513C-HxCB(156/157)156/157 1.30 4.045.249 2.56 6413C-2,3',4,4',5,5'-HxCB 167 1.26 2.044.042 1.24 6213C-3,3',4,4',5,5'-HxCB 169 1.25 2.048.536 1.41 7113C-2,2',3,4',5,6,6'-HpCB 188 1.02 2.038.251 1.08 5413C-2,3,3',4,4',5,5'-HpCB 189 1.16 2.051.047 1.45 7313C-2,2',3,3',5,5',6,6'-OcCB 202 0.91 2.043.740 1.17 5913C-2,3,3',4,4',5,5',6-OcCB 205 0.93 2.053.095 1.32 6613C-2,2',3,3',4,4',5,5',6-NoCB 206 0.73 2.054.539 1.24 6213C-2,2',3,3',4,5,5',6,6'-NoCB 208 0.85 2.050.508 1.21 6013C--DeCB 209 0.75 2.055.983 1.19 59 CleanupStandards13C-2,4,4'-TrCB 28 1.01 2.023.283 1.52 7613C-2,3,3',5,5'-PeCB 111 1.65 2.035.379 1.41 7113C-2,2',3,3',5,5',6-HpCB 178 1.03 2.041.387 1.31 65 Recovery Standards13C-2,5-DiCB 9 1.55 2.015.193 NA NA13C-2,2',5,5'-TeCB 52 0.78 2.025.278 NA NA13C-2,2',4,5,5'-PeCB 101 1.54 2.032.595 NA NA13C-2,2',3,4,4',5'-HxCB 138 1.25 2.040.968 NA NA13C-2,2',3,3',4,4',5,5'-OcCB 194 1.00 2.052.728 NA NA Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Page 9 of 60Report No.....10439554_1668_209_DFR Page 28 of 79 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SW008-F005 P180721B_08Lab Sample ID 92391738001 Co-elutions RT ng/L EMLEMPCConcentration ng/LIUPACRatio ng/L 1 ---ND------0.2712---ND------0.2713---ND------0.271 4 1.59 0.35712.739 ---0.2715---ND------0.2716---ND------0.2717---ND------0.27181.38 0.33116.248 ---0.271 9 ---ND------0.27110---ND------0.27111---ND------2.66 12 12/13 ---ND------0.5431312/13 ---ND------0.54314---ND------0.271 15 1.54 0.95919.902 ---0.35816---ND------0.271171.07 0.69419.291 ---0.2711818/30 ---ND------0.543191.19 0.28916.595 ---0.2712020/28 1.06 1.4323.316 ---1.402121/33 ---ND------1.4722---ND------1.03 23 ---ND------0.27124---ND------0.27125---ND------0.271 26 26/29 ---ND------0.54327---ND------0.2712820/28 1.06 (1.43)23.316 ---1.40 29 26/29 ---ND------0.5433018/30 ---ND------0.54331---ND------1.41321.05 0.51920.415 ---0.2713321/33 ---ND------1.47 34 ---ND------0.27135---ND------0.27136---ND------0.271 37 ---ND------0.57538---ND------0.27139---ND------0.271 40 40/41/71 ---ND------1.634140/41/71 ---ND------1.63420.76 0.61526.955 ---0.5434343/73 ---ND------0.5434444/47/65 0.79 2.9226.452 ---1.634545/51 ---ND------1.0946---ND------0.5434744/47/65 0.79 (2.92)26.452 ---1.63 48 ---ND------0.543 Page 10 of 60Report No.....10439554_1668_209_DFR Page 29 of 79 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SW008-F005 P180721B_08Lab Sample ID 92391738001 Co-elutions RT ng/L EMLEMPCConcentration ng/LIUPACRatio ng/L 49 49/69 0.77 1.7725.832 ---1.095050/53 ---ND------1.095145/51 ---ND------1.09 52 0.76 2.2125.312 ---1.675350/53 ---ND------1.0954---ND------0.54355---ND------0.543560.75 1.2731.538 ---0.543 57 ---ND------0.54358---ND------0.5435959/62/75 ---ND------1.63 60 ---ND------0.5436161/70/74/76 0.78 3.7930.465 ---2.176259/62/75 ---ND------1.63 63 ---ND------0.543640.78 1.0627.726 ---0.5436544/47/65 0.79 (2.92)26.452 ---1.63660.81 3.1930.801 ---0.91267---ND------0.54368---ND------0.5436949/69 0.77 (1.77)25.832 ---1.097061/70/74/76 0.78 (3.79)30.465 ---2.17 71 40/41/71 ---ND------1.6372---ND------0.5437343/73 ---ND------0.543 74 61/70/74/76 0.78 (3.79)30.465 ---2.177559/62/75 ---ND------1.637661/70/74/76 0.78 (3.79)30.465 ---2.17 77 ---ND------0.54378---ND------0.54379---ND------0.54380---ND------0.54381---ND------0.543 82 ---ND------0.54383---ND------0.54384---ND------0.543 85 85/116/117 ---ND------1.638686/87/97/108/119/125 ---ND------3.268786/87/97/108/119/125 ---ND------3.26 88 88/91 ---ND------1.0989---ND------0.5439090/101/113 1.66 1.7432.629 ---1.639188/91 ---ND------1.0992---ND------0.5439393/98/100/102 ---ND------2.1794---ND------0.543951.50 1.2529.526 ---1.03 96 ---ND------0.543 Page 11 of 60Report No.....10439554_1668_209_DFR Page 30 of 79 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SW008-F005 P180721B_08Lab Sample ID 92391738001 Co-elutions RT ng/L EMLEMPCConcentration ng/LIUPACRatio ng/L 97 86/87/97/108/119/125 ---ND------3.269893/98/100/102 ---ND------2.17991.52 1.3933.232 ---0.543 100 93/98/100/102 ---ND------2.1710190/101/113 1.66 (1.74)32.629 ---1.6310293/98/100/102 ---ND------2.17103---ND------0.543104---ND------0.543 105 1.52 0.89739.039 ---0.543106---ND------0.543107107/124 ---ND------1.09 108 86/87/97/108/119/125 ---ND------3.26109---ND------0.543110110/115 1.53 2.3434.691 ---1.09 111 ---ND------0.543112---ND------0.54311390/101/113 1.66 (1.74)32.629 ---1.63114---ND------0.543115110/115 1.53 (2.34)34.691 ---1.0911685/116/117 ---ND------1.6311785/116/117 ---ND------1.631181.47 1.7437.799 ---0.695 119 86/87/97/108/119/125 ---ND------3.26120---ND------0.543121---ND------0.543 122 ---ND------0.543123---ND------0.543124107/124 ---ND------1.09 125 86/87/97/108/119/125 ---ND------3.26126---ND------0.543127---ND------0.543128128/166 ---ND------1.09129129/138/163 ---ND------1.63 130 ---ND------0.543131---ND------0.543132---ND------0.543 133 ---ND------0.543134134/143 ---ND------1.09135135/151 ---ND------1.09 136 ---ND------0.543137---ND------0.543138129/138/163 ---ND------1.63139139/140 ---ND------1.09140139/140 ---ND------1.09141---ND------0.543142---ND------0.543143134/143 ---ND------1.09 144 ---ND------0.543 Page 12 of 60Report No.....10439554_1668_209_DFR Page 31 of 79 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SW008-F005 P180721B_08Lab Sample ID 92391738001 Co-elutions RT ng/L EMLEMPCConcentration ng/LIUPACRatio ng/L 145 ---ND------0.543146---ND------0.543147147/149 ---ND------1.09 148 ---ND------0.543149147/149 ---ND------1.09150---ND------0.543151135/151 ---ND------1.09152---ND------0.543 153 153/168 ---ND------1.09154---ND------0.543155---ND------0.543 156 156/157 ---ND------1.09157156/157 ---ND------1.09158---ND------0.543 159 ---ND------0.543160---ND------0.543161---ND------0.543162---ND------0.543163129/138/163 ---ND------1.63164---ND------0.543165---ND------0.543166128/166 ---ND------1.09 167 ---ND------0.543168153/168 ---ND------1.09169---ND------0.543 170 ---ND------0.543171171/173 ---ND------1.09172---ND------0.543 173 171/173 ---ND------1.09174---ND------0.543175---ND------0.543176---ND------0.543177---ND------0.543 178 ---ND------0.543179---ND------0.543180180/193 ---ND------1.09 181 ---ND------0.543182---ND------0.543183183/185 ---ND------1.09 184 ---ND------0.543185183/185 ---ND------1.09186---ND------0.543187---ND------0.543188---ND------0.543189---ND------0.543190---ND------0.543191---ND------0.543 192 ---ND------0.543 Page 13 of 60Report No.....10439554_1668_209_DFR Page 32 of 79 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SW008-F005 P180721B_08Lab Sample ID 92391738001 Co-elutions RT ng/L EMLEMPCConcentration ng/LIUPACRatio ng/L 193 180/193 ---ND------1.09194---ND------0.814195---ND------0.814 196 ---ND------0.814197197/200 ---ND------1.63198198/199 ---ND------1.63199198/199 ---ND------1.63200197/200 ---ND------1.63 201 ---ND------0.814202---ND------0.814203---ND------0.814 204 ---ND------0.814205---ND------0.814206---ND------0.814 207 ---ND------0.814208---ND------0.814209---ND------0.814 Page 14 of 60Report No.....10439554_1668_209_DFR Page 33 of 79 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SW008-F005 P180721B_08 Sample Analysis Results Lab Sample ID 92391738001 Congener Group Concentration ng/L Total MonochloroBiphenyls ND TotalDichloroBiphenyls 1.65 Total TrichloroBiphenyls 2.93 Total TetrachloroBiphenyls 16.8 TotalPentachloroBiphenyls 9.35 TotalHexachloroBiphenyls ND TotalHeptachloroBiphenyls ND Total Octachloro Biphenyls ND TotalNonachloroBiphenyls ND DecachloroBiphenyls ND Total PCBs 30.8 ND = Not Detected Page 15 of 60Report No.....10439554_1668_209_DFR Page 34 of 79 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Client - PACE Charlotte Client's Sample ID Lab Sample ID Filename Injected ByTotal Amount Extracted% Moisture Dry Weight Extracted ICAL ID CCal Filename(s)Method Blank ID BLANK-63512P180721B_01 P180721B02 NA NA941 mLBAL P180721B_09 92391738002 ABL-SW008-D005 MatrixDilution Collected Received ExtractedAnalyzed 07/22/2018 01:5307/17/2018 13:15 07/14/2018 09:30 07/12/2018 NAWater Method 1668A Polychlorobiphenyl Sample Analysis Results PCB Isomer RT % Recoveryng's Foundng's AddedIUPACRatio LabeledAnalytes13C-2-MoCB 1 2.67 2.09.587 1.02 5113C-4-MoCB 3 3.02 2.012.416 1.23 6213C-2,2'-DiCB 4 1.66 2.012.715 1.13 5613C-4,4'-DiCB 15 1.64 2.019.867 1.42 7113C-2,2',6-TrCB 19 1.12 2.016.572 1.41 7013C-3,4,4'-TrCB 37 1.04 2.027.694 1.58 7913C-2,2',6,6'-TeCB 54 0.86 2.020.181 1.15 5713C-3,4,4',5-TeCB 81 0.84 2.034.826 1.69 8513C-3,3',4,4'-TeCB 77 0.81 2.035.413 1.68 8413C-2,2',4,6,6'-PeCB 104 1.72 2.026.302 1.24 6213C-2,3,3',4,4'-PeCB 105 1.61 2.039.007 1.84 9213C-2,3,4,4',5-PeCB 114 1.53 2.038.336 1.74 8713C-2,3',4,4',5-PeCB 118 1.67 2.037.766 1.82 9113C-2,3',4,4',5'-PeCB 123 1.58 2.037.431 1.80 9013C-3,3',4,4',5-PeCB 126 1.56 2.042.176 1.94 9713C-2,2',4,4',6,6'-HxCB 155 1.25 2.032.327 1.24 6213C-HxCB(156/157)156/157 1.32 4.045.217 3.34 8413C-2,3',4,4',5,5'-HxCB 167 1.31 2.044.026 1.71 8613C-3,3',4,4',5,5'-HxCB 169 1.29 2.048.537 1.82 9113C-2,2',3,4',5,6,6'-HpCB 188 1.03 2.038.235 1.36 6813C-2,3,3',4,4',5,5'-HpCB 189 1.05 2.051.048 1.70 8513C-2,2',3,3',5,5',6,6'-OcCB 202 0.90 2.043.724 1.42 7113C-2,3,3',4,4',5,5',6-OcCB 205 0.91 2.053.095 1.55 7713C-2,2',3,3',4,4',5,5',6-NoCB 206 0.83 2.054.518 1.50 7513C-2,2',3,3',4,5,5',6,6'-NoCB 208 0.81 2.050.509 1.47 7413C--DeCB 209 0.69 2.055.983 1.41 71 CleanupStandards13C-2,4,4'-TrCB 28 1.12 2.023.284 1.74 8713C-2,3,3',5,5'-PeCB 111 1.60 2.035.379 1.80 9013C-2,2',3,3',5,5',6-HpCB 178 1.06 2.041.388 1.65 82 Recovery Standards13C-2,5-DiCB 9 1.59 2.015.182 NA NA13C-2,2',5,5'-TeCB 52 0.86 2.025.279 NA NA13C-2,2',4,5,5'-PeCB 101 1.50 2.032.579 NA NA13C-2,2',3,4,4',5'-HxCB 138 1.25 2.040.969 NA NA13C-2,2',3,3',4,4',5,5'-OcCB 194 0.91 2.052.707 NA NA Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Page 16 of 60Report No.....10439554_1668_209_DFR Page 35 of 79 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SW008-D005 P180721B_09Lab Sample ID 92391738002 Co-elutions RT ng/L EMLEMPCConcentration ng/LIUPACRatio ng/L 1 ---ND------0.2662---ND------0.2663---ND------0.266 4 ---ND------0.2665---ND------0.2666---ND------0.2667---ND------0.2668---ND------0.266 9 ---ND------0.26610---ND------0.26611---ND------2.60 12 12/13 ---ND------0.5311312/13 ---ND------0.53114---ND------0.266 15 ---ND------0.35116---ND------0.26617---ND------0.2661818/30 ---ND------0.53119---ND------0.2662020/28 ---ND------1.372121/33 ---ND------1.4322---ND------1.01 23 ---ND------0.26624---ND------0.26625---ND------0.266 26 26/29 ---ND------0.53127---ND------0.2662820/28 ---ND------1.37 29 26/29 ---ND------0.5313018/30 ---ND------0.53131---ND------1.3832---ND------0.2663321/33 ---ND------1.43 34 ---ND------0.26635---ND------0.26636---ND------0.266 37 ---ND------0.56338---ND------0.26639---ND------0.266 40 40/41/71 ---ND------1.594140/41/71 ---ND------1.5942---ND------0.5314343/73 ---ND------0.5314444/47/65 ---ND------1.594545/51 ---ND------1.0646---ND------0.5314744/47/65 ---ND------1.59 48 ---ND------0.531 Page 17 of 60Report No.....10439554_1668_209_DFR Page 36 of 79 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SW008-D005 P180721B_09Lab Sample ID 92391738002 Co-elutions RT ng/L EMLEMPCConcentration ng/LIUPACRatio ng/L 49 49/69 ---ND------1.065050/53 ---ND------1.065145/51 ---ND------1.06 52 ---ND------1.645350/53 ---ND------1.0654---ND------0.53155---ND------0.53156---ND------0.531 57 ---ND------0.53158---ND------0.5315959/62/75 ---ND------1.59 60 ---ND------0.5316161/70/74/76 ---ND------2.136259/62/75 ---ND------1.59 63 ---ND------0.53164---ND------0.5316544/47/65 ---ND------1.5966---ND------0.89367---ND------0.53168---ND------0.5316949/69 ---ND------1.067061/70/74/76 ---ND------2.13 71 40/41/71 ---ND------1.5972---ND------0.5317343/73 ---ND------0.531 74 61/70/74/76 ---ND------2.137559/62/75 ---ND------1.597661/70/74/76 ---ND------2.13 77 ---ND------0.53178---ND------0.53179---ND------0.53180---ND------0.53181---ND------0.531 82 ---ND------0.53183---ND------0.53184---ND------0.531 85 85/116/117 ---ND------1.598686/87/97/108/119/125 ---ND------3.198786/87/97/108/119/125 ---ND------3.19 88 88/91 ---ND------1.0689---ND------0.5319090/101/113 ---ND------1.599188/91 ---ND------1.0692---ND------0.5319393/98/100/102 ---ND------2.1394---ND------0.53195---ND------1.01 96 ---ND------0.531 Page 18 of 60Report No.....10439554_1668_209_DFR Page 37 of 79 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SW008-D005 P180721B_09Lab Sample ID 92391738002 Co-elutions RT ng/L EMLEMPCConcentration ng/LIUPACRatio ng/L 97 86/87/97/108/119/125 ---ND------3.199893/98/100/102 ---ND------2.1399---ND------0.531 100 93/98/100/102 ---ND------2.1310190/101/113 ---ND------1.5910293/98/100/102 ---ND------2.13103---ND------0.531104---ND------0.531 105 ---ND------0.531106---ND------0.531107107/124 ---ND------1.06 108 86/87/97/108/119/125 ---ND------3.19109---ND------0.531110110/115 ---ND------1.06 111 ---ND------0.531112---ND------0.53111390/101/113 ---ND------1.59114---ND------0.531115110/115 ---ND------1.0611685/116/117 ---ND------1.5911785/116/117 ---ND------1.59118---ND------0.680 119 86/87/97/108/119/125 ---ND------3.19120---ND------0.531121---ND------0.531 122 ---ND------0.531123---ND------0.531124107/124 ---ND------1.06 125 86/87/97/108/119/125 ---ND------3.19126---ND------0.531127---ND------0.531128128/166 ---ND------1.06129129/138/163 ---ND------1.59 130 ---ND------0.531131---ND------0.531132---ND------0.531 133 ---ND------0.531134134/143 ---ND------1.06135135/151 ---ND------1.06 136 ---ND------0.531137---ND------0.531138129/138/163 ---ND------1.59139139/140 ---ND------1.06140139/140 ---ND------1.06141---ND------0.531142---ND------0.531143134/143 ---ND------1.06 144 ---ND------0.531 Page 19 of 60Report No.....10439554_1668_209_DFR Page 38 of 79 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SW008-D005 P180721B_09Lab Sample ID 92391738002 Co-elutions RT ng/L EMLEMPCConcentration ng/LIUPACRatio ng/L 145 ---ND------0.531146---ND------0.531147147/149 ---ND------1.06 148 ---ND------0.531149147/149 ---ND------1.06150---ND------0.531151135/151 ---ND------1.06152---ND------0.531 153 153/168 ---ND------1.06154---ND------0.531155---ND------0.531 156 156/157 ---ND------1.06157156/157 ---ND------1.06158---ND------0.531 159 ---ND------0.531160---ND------0.531161---ND------0.531162---ND------0.531163129/138/163 ---ND------1.59164---ND------0.531165---ND------0.531166128/166 ---ND------1.06 167 ---ND------0.531168153/168 ---ND------1.06169---ND------0.531 170 ---ND------0.531171171/173 ---ND------1.06172---ND------0.531 173 171/173 ---ND------1.06174---ND------0.531175---ND------0.531176---ND------0.531177---ND------0.531 178 ---ND------0.531179---ND------0.531180180/193 ---ND------1.06 181 ---ND------0.531182---ND------0.531183183/185 ---ND------1.06 184 ---ND------0.531185183/185 ---ND------1.06186---ND------0.531187---ND------0.531188---ND------0.531189---ND------0.531190---ND------0.531191---ND------0.531 192 ---ND------0.531 Page 20 of 60Report No.....10439554_1668_209_DFR Page 39 of 79 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SW008-D005 P180721B_09Lab Sample ID 92391738002 Co-elutions RT ng/L EMLEMPCConcentration ng/LIUPACRatio ng/L 193 180/193 ---ND------1.06194---ND------0.797195---ND------0.797 196 ---ND------0.797197197/200 ---ND------1.59198198/199 ---ND------1.59199198/199 ---ND------1.59200197/200 ---ND------1.59 201 ---ND------0.797202---ND------0.797203---ND------0.797 204 ---ND------0.797205---ND------0.797206---ND------0.797 207 ---ND------0.797208---ND------0.797209---ND------0.797 Page 21 of 60Report No.....10439554_1668_209_DFR Page 40 of 79 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SW008-D005 P180721B_09 Sample Analysis Results Lab Sample ID 92391738002 Congener Group Concentration ng/L Total MonochloroBiphenyls ND TotalDichloroBiphenyls ND Total TrichloroBiphenyls ND Total TetrachloroBiphenyls ND TotalPentachloroBiphenyls ND TotalHexachloroBiphenyls ND TotalHeptachloroBiphenyls ND Total Octachloro Biphenyls ND TotalNonachloroBiphenyls ND DecachloroBiphenyls ND Total PCBs ND ND = Not Detected Page 22 of 60Report No.....10439554_1668_209_DFR Page 41 of 79 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Client - PACE Charlotte Client's Sample ID Lab Sample ID Filename Injected ByTotal Amount Extracted% Moisture Dry Weight Extracted ICAL ID CCal Filename(s)Method Blank ID BLANK-63512P180721B_01 P180721B02 NA NA987 mLBAL P180721B_10 92391738003 ABL-SW009-F005 MatrixDilution Collected Received ExtractedAnalyzed 07/22/2018 02:5207/17/2018 13:15 07/14/2018 09:30 07/12/2018 NAWater Method 1668A Polychlorobiphenyl Sample Analysis Results PCB Isomer RT % Recoveryng's Foundng's AddedIUPACRatio LabeledAnalytes13C-2-MoCB 1 3.15 2.09.587 0.756 3813C-4-MoCB 3 3.05 2.012.427 0.970 4813C-2,2'-DiCB 4 1.57 2.012.714 0.908 4513C-4,4'-DiCB 15 1.63 2.019.876 1.18 5913C-2,2',6-TrCB 19 1.04 2.016.570 1.04 5213C-3,4,4'-TrCB 37 0.95 2.027.707 1.42 7113C-2,2',6,6'-TeCB 54 0.87 2.020.195 0.952 4813C-3,4,4',5-TeCB 81 0.74 2.034.839 1.38 6913C-3,3',4,4'-TeCB 77 0.85 2.035.425 1.29 6413C-2,2',4,6,6'-PeCB 104 1.56 2.026.299 1.02 5113C-2,3,3',4,4'-PeCB 105 1.58 2.039.019 1.49 7513C-2,3,4,4',5-PeCB 114 1.57 2.038.348 1.49 7413C-2,3',4,4',5-PeCB 118 1.53 2.037.778 1.46 7313C-2,3',4,4',5'-PeCB 123 1.59 2.037.426 1.46 7313C-3,3',4,4',5-PeCB 126 1.72 2.042.205 1.51 7613C-2,2',4,4',6,6'-HxCB 155 1.31 2.032.324 1.02 5113C-HxCB(156/157)156/157 1.35 4.045.245 2.67 6713C-2,3',4,4',5,5'-HxCB 167 1.15 2.044.055 1.35 6813C-3,3',4,4',5,5'-HxCB 169 1.31 2.048.548 1.48 7413C-2,2',3,4',5,6,6'-HpCB 188 1.06 2.038.248 1.22 6113C-2,3,3',4,4',5,5'-HpCB 189 1.02 2.051.042 1.46 7313C-2,2',3,3',5,5',6,6'-OcCB 202 0.91 2.043.736 1.28 6413C-2,3,3',4,4',5,5',6-OcCB 205 0.87 2.053.111 1.38 6913C-2,2',3,3',4,4',5,5',6-NoCB 206 0.83 2.054.555 1.32 6613C-2,2',3,3',4,5,5',6,6'-NoCB 208 0.78 2.050.503 1.30 6513C--DeCB 209 0.70 2.056.020 1.31 66 CleanupStandards13C-2,4,4'-TrCB 28 0.92 2.023.281 1.60 8013C-2,3,3',5,5'-PeCB 111 1.68 2.035.392 1.55 7813C-2,2',3,3',5,5',6-HpCB 178 1.01 2.041.383 1.47 73 Recovery Standards13C-2,5-DiCB 9 1.58 2.015.204 NA NA13C-2,2',5,5'-TeCB 52 0.84 2.025.292 NA NA13C-2,2',4,5,5'-PeCB 101 1.65 2.032.592 NA NA13C-2,2',3,4,4',5'-HxCB 138 1.27 2.040.964 NA NA13C-2,2',3,3',4,4',5,5'-OcCB 194 0.93 2.052.723 NA NA Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Page 23 of 60Report No.....10439554_1668_209_DFR Page 42 of 79 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SW009-F005 P180721B_10Lab Sample ID 92391738003 Co-elutions RT ng/L EMLEMPCConcentration ng/LIUPACRatio ng/L 1 ---ND------0.2532---ND------0.2533---ND------0.253 4 ---ND------0.2535---ND------0.2536---ND------0.2537---ND------0.2538---ND------0.253 9 ---ND------0.25310---ND------0.25311---ND------2.48 12 12/13 ---ND------0.5061312/13 ---ND------0.50614---ND------0.253 15 ---ND------0.33416---ND------0.25317---ND------0.2531818/30 ---ND------0.50619---ND------0.2532020/28 ---ND------1.312121/33 ---ND------1.3722---ND------0.962 23 ---ND------0.25324---ND------0.25325---ND------0.253 26 26/29 ---ND------0.50627---ND------0.2532820/28 ---ND------1.31 29 26/29 ---ND------0.5063018/30 ---ND------0.50631---ND------1.3232---ND------0.2533321/33 ---ND------1.37 34 ---ND------0.25335---ND------0.25336---ND------0.253 37 ---ND------0.53738---ND------0.25339---ND------0.253 40 40/41/71 ---ND------1.524140/41/71 ---ND------1.5242---ND------0.5064343/73 ---ND------0.5064444/47/65 ---ND------1.524545/51 ---ND------1.0146---ND------0.5064744/47/65 ---ND------1.52 48 ---ND------0.506 Page 24 of 60Report No.....10439554_1668_209_DFR Page 43 of 79 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SW009-F005 P180721B_10Lab Sample ID 92391738003 Co-elutions RT ng/L EMLEMPCConcentration ng/LIUPACRatio ng/L 49 49/69 ---ND------1.015050/53 ---ND------1.015145/51 ---ND------1.01 52 ---ND------1.565350/53 ---ND------1.0154---ND------0.50655---ND------0.50656---ND------0.506 57 ---ND------0.50658---ND------0.5065959/62/75 ---ND------1.52 60 ---ND------0.5066161/70/74/76 ---ND------2.036259/62/75 ---ND------1.52 63 ---ND------0.50664---ND------0.5066544/47/65 ---ND------1.5266---ND------0.85167---ND------0.50668---ND------0.5066949/69 ---ND------1.017061/70/74/76 ---ND------2.03 71 40/41/71 ---ND------1.5272---ND------0.5067343/73 ---ND------0.506 74 61/70/74/76 ---ND------2.037559/62/75 ---ND------1.527661/70/74/76 ---ND------2.03 77 ---ND------0.50678---ND------0.50679---ND------0.50680---ND------0.50681---ND------0.506 82 ---ND------0.50683---ND------0.50684---ND------0.506 85 85/116/117 ---ND------1.528686/87/97/108/119/125 ---ND------3.048786/87/97/108/119/125 ---ND------3.04 88 88/91 ---ND------1.0189---ND------0.5069090/101/113 ---ND------1.529188/91 ---ND------1.0192---ND------0.5069393/98/100/102 ---ND------2.0394---ND------0.50695---ND------0.962 96 ---ND------0.506 Page 25 of 60Report No.....10439554_1668_209_DFR Page 44 of 79 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SW009-F005 P180721B_10Lab Sample ID 92391738003 Co-elutions RT ng/L EMLEMPCConcentration ng/LIUPACRatio ng/L 97 86/87/97/108/119/125 ---ND------3.049893/98/100/102 ---ND------2.0399---ND------0.506 100 93/98/100/102 ---ND------2.0310190/101/113 ---ND------1.5210293/98/100/102 ---ND------2.03103---ND------0.506104---ND------0.506 105 ---ND------0.506106---ND------0.506107107/124 ---ND------1.01 108 86/87/97/108/119/125 ---ND------3.04109---ND------0.506110110/115 ---ND------1.01 111 ---ND------0.506112---ND------0.50611390/101/113 ---ND------1.52114---ND------0.506115110/115 ---ND------1.0111685/116/117 ---ND------1.5211785/116/117 ---ND------1.52118---ND------0.648 119 86/87/97/108/119/125 ---ND------3.04120---ND------0.506121---ND------0.506 122 ---ND------0.506123---ND------0.506124107/124 ---ND------1.01 125 86/87/97/108/119/125 ---ND------3.04126---ND------0.506127---ND------0.506128128/166 ---ND------1.01129129/138/163 ---ND------1.52 130 ---ND------0.506131---ND------0.506132---ND------0.506 133 ---ND------0.506134134/143 ---ND------1.01135135/151 ---ND------1.01 136 ---ND------0.506137---ND------0.506138129/138/163 ---ND------1.52139139/140 ---ND------1.01140139/140 ---ND------1.01141---ND------0.506142---ND------0.506143134/143 ---ND------1.01 144 ---ND------0.506 Page 26 of 60Report No.....10439554_1668_209_DFR Page 45 of 79 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SW009-F005 P180721B_10Lab Sample ID 92391738003 Co-elutions RT ng/L EMLEMPCConcentration ng/LIUPACRatio ng/L 145 ---ND------0.506146---ND------0.506147147/149 ---ND------1.01 148 ---ND------0.506149147/149 ---ND------1.01150---ND------0.506151135/151 ---ND------1.01152---ND------0.506 153 153/168 ---ND------1.01154---ND------0.506155---ND------0.506 156 156/157 ---ND------1.01157156/157 ---ND------1.01158---ND------0.506 159 ---ND------0.506160---ND------0.506161---ND------0.506162---ND------0.506163129/138/163 ---ND------1.52164---ND------0.506165---ND------0.506166128/166 ---ND------1.01 167 ---ND------0.506168153/168 ---ND------1.01169---ND------0.506 170 ---ND------0.506171171/173 ---ND------1.01172---ND------0.506 173 171/173 ---ND------1.01174---ND------0.506175---ND------0.506176---ND------0.506177---ND------0.506 178 ---ND------0.506179---ND------0.506180180/193 ---ND------1.01 181 ---ND------0.506182---ND------0.506183183/185 ---ND------1.01 184 ---ND------0.506185183/185 ---ND------1.01186---ND------0.506187---ND------0.506188---ND------0.506189---ND------0.506190---ND------0.506191---ND------0.506 192 ---ND------0.506 Page 27 of 60Report No.....10439554_1668_209_DFR Page 46 of 79 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SW009-F005 P180721B_10Lab Sample ID 92391738003 Co-elutions RT ng/L EMLEMPCConcentration ng/LIUPACRatio ng/L 193 180/193 ---ND------1.01194---ND------0.760195---ND------0.760 196 ---ND------0.760197197/200 ---ND------1.52198198/199 ---ND------1.52199198/199 ---ND------1.52200197/200 ---ND------1.52 201 ---ND------0.760202---ND------0.760203---ND------0.760 204 ---ND------0.760205---ND------0.760206---ND------0.760 207 ---ND------0.760208---ND------0.760209---ND------0.760 Page 28 of 60Report No.....10439554_1668_209_DFR Page 47 of 79 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SW009-F005 P180721B_10 Sample Analysis Results Lab Sample ID 92391738003 Congener Group Concentration ng/L Total MonochloroBiphenyls ND TotalDichloroBiphenyls ND Total TrichloroBiphenyls ND Total TetrachloroBiphenyls ND TotalPentachloroBiphenyls ND TotalHexachloroBiphenyls ND TotalHeptachloroBiphenyls ND Total Octachloro Biphenyls ND TotalNonachloroBiphenyls ND DecachloroBiphenyls ND Total PCBs ND ND = Not Detected Page 29 of 60Report No.....10439554_1668_209_DFR Page 48 of 79 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Client - PACE Charlotte Client's Sample ID Lab Sample ID Filename Injected ByTotal Amount Extracted% Moisture Dry Weight Extracted ICAL ID CCal Filename(s)Method Blank ID BLANK-63512P180721B_01 P180721B02 NA NA966 mLBAL P180721B_11 92391738004 ABL-SW010-F005 MatrixDilution Collected Received ExtractedAnalyzed 07/22/2018 03:5207/17/2018 13:15 07/14/2018 09:30 07/12/2018 NAWater Method 1668A Polychlorobiphenyl Sample Analysis Results PCB Isomer RT % Recoveryng's Foundng's AddedIUPACRatio LabeledAnalytes13C-2-MoCB 1 2.74 2.09.576 0.886 4413C-4-MoCB 3 2.75 2.012.428 1.03 5213C-2,2'-DiCB 4 1.67 2.012.727 0.983 4913C-4,4'-DiCB 15 1.57 2.019.880 1.31 6613C-2,2',6-TrCB 19 1.08 2.016.560 1.26 6313C-3,4,4'-TrCB 37 1.16 2.027.694 1.57 7913C-2,2',6,6'-TeCB 54 0.83 2.020.199 1.06 5313C-3,4,4',5-TeCB 81 0.84 2.034.825 1.60 8013C-3,3',4,4'-TeCB 77 0.81 2.035.429 1.62 8113C-2,2',4,6,6'-PeCB 104 1.50 2.026.302 1.15 5713C-2,3,3',4,4'-PeCB 105 1.50 2.038.989 1.69 8513C-2,3,4,4',5-PeCB 114 1.50 2.038.318 1.68 8413C-2,3',4,4',5-PeCB 118 1.58 2.037.765 1.72 8613C-2,3',4,4',5'-PeCB 123 1.63 2.037.430 1.65 8313C-3,3',4,4',5-PeCB 126 1.62 2.042.175 1.80 9013C-2,2',4,4',6,6'-HxCB 155 1.23 2.032.327 1.18 5913C-HxCB(156/157)156/157 1.38 4.045.249 3.18 7913C-2,3',4,4',5,5'-HxCB 167 1.30 2.044.025 1.58 7913C-3,3',4,4',5,5'-HxCB 169 1.24 2.048.551 1.64 8213C-2,2',3,4',5,6,6'-HpCB 188 0.96 2.038.251 1.39 6913C-2,3,3',4,4',5,5'-HpCB 189 1.06 2.051.023 1.67 8413C-2,2',3,3',5,5',6,6'-OcCB 202 0.90 2.043.739 1.36 6813C-2,3,3',4,4',5,5',6-OcCB 205 0.91 2.053.114 1.58 7913C-2,2',3,3',4,4',5,5',6-NoCB 206 0.89 2.054.515 1.42 7113C-2,2',3,3',4,5,5',6,6'-NoCB 208 0.85 2.050.506 1.41 7113C--DeCB 209 0.70 2.055.980 1.48 74 CleanupStandards13C-2,4,4'-TrCB 28 1.03 2.023.284 1.73 8613C-2,3,3',5,5'-PeCB 111 1.58 2.035.379 1.66 8313C-2,2',3,3',5,5',6-HpCB 178 1.06 2.041.387 1.62 81 Recovery Standards13C-2,5-DiCB 9 1.59 2.015.182 NA NA13C-2,2',5,5'-TeCB 52 0.79 2.025.263 NA NA13C-2,2',4,5,5'-PeCB 101 1.49 2.032.578 NA NA13C-2,2',3,4,4',5'-HxCB 138 1.24 2.040.951 NA NA13C-2,2',3,3',4,4',5,5'-OcCB 194 0.88 2.052.726 NA NA Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Page 30 of 60Report No.....10439554_1668_209_DFR Page 49 of 79 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SW010-F005 P180721B_11Lab Sample ID 92391738004 Co-elutions RT ng/L EMLEMPCConcentration ng/LIUPACRatio ng/L 1 ---ND------0.2592---ND------0.2593---ND------0.259 4 ---ND------0.2595---ND------0.2596---ND------0.2597---ND------0.2598---ND------0.259 9 ---ND------0.25910---ND------0.25911---ND------2.54 12 12/13 ---ND------0.5181312/13 ---ND------0.51814---ND------0.259 15 ---ND------0.34216---ND------0.25917---ND------0.2591818/30 ---ND------0.51819---ND------0.2592020/28 ---ND------1.342121/33 ---ND------1.4022---ND------0.983 23 ---ND------0.25924---ND------0.25925---ND------0.259 26 26/29 ---ND------0.51827---ND------0.2592820/28 ---ND------1.34 29 26/29 ---ND------0.5183018/30 ---ND------0.51831---ND------1.3532---ND------0.2593321/33 ---ND------1.40 34 ---ND------0.25935---ND------0.25936---ND------0.259 37 ---ND------0.54938---ND------0.25939---ND------0.259 40 40/41/71 ---ND------1.554140/41/71 ---ND------1.5542---ND------0.5184343/73 ---ND------0.5184444/47/65 ---ND------1.554545/51 ---ND------1.0446---ND------0.5184744/47/65 ---ND------1.55 48 ---ND------0.518 Page 31 of 60Report No.....10439554_1668_209_DFR Page 50 of 79 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SW010-F005 P180721B_11Lab Sample ID 92391738004 Co-elutions RT ng/L EMLEMPCConcentration ng/LIUPACRatio ng/L 49 49/69 ---ND------1.045050/53 ---ND------1.045145/51 ---ND------1.04 52 ---ND------1.595350/53 ---ND------1.0454---ND------0.51855---ND------0.51856---ND------0.518 57 ---ND------0.51858---ND------0.5185959/62/75 ---ND------1.55 60 ---ND------0.5186161/70/74/76 ---ND------2.076259/62/75 ---ND------1.55 63 ---ND------0.51864---ND------0.5186544/47/65 ---ND------1.5566---ND------0.86967---ND------0.51868---ND------0.5186949/69 ---ND------1.047061/70/74/76 ---ND------2.07 71 40/41/71 ---ND------1.5572---ND------0.5187343/73 ---ND------0.518 74 61/70/74/76 ---ND------2.077559/62/75 ---ND------1.557661/70/74/76 ---ND------2.07 77 ---ND------0.51878---ND------0.51879---ND------0.51880---ND------0.51881---ND------0.518 82 ---ND------0.51883---ND------0.51884---ND------0.518 85 85/116/117 ---ND------1.558686/87/97/108/119/125 ---ND------3.118786/87/97/108/119/125 ---ND------3.11 88 88/91 ---ND------1.0489---ND------0.5189090/101/113 ---ND------1.559188/91 ---ND------1.0492---ND------0.5189393/98/100/102 ---ND------2.0794---ND------0.51895---ND------0.983 96 ---ND------0.518 Page 32 of 60Report No.....10439554_1668_209_DFR Page 51 of 79 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SW010-F005 P180721B_11Lab Sample ID 92391738004 Co-elutions RT ng/L EMLEMPCConcentration ng/LIUPACRatio ng/L 97 86/87/97/108/119/125 ---ND------3.119893/98/100/102 ---ND------2.0799---ND------0.518 100 93/98/100/102 ---ND------2.0710190/101/113 ---ND------1.5510293/98/100/102 ---ND------2.07103---ND------0.518104---ND------0.518 105 ---ND------0.518106---ND------0.518107107/124 ---ND------1.04 108 86/87/97/108/119/125 ---ND------3.11109---ND------0.518110110/115 ---ND------1.04 111 ---ND------0.518112---ND------0.51811390/101/113 ---ND------1.55114---ND------0.518115110/115 ---ND------1.0411685/116/117 ---ND------1.5511785/116/117 ---ND------1.55118---ND------0.662 119 86/87/97/108/119/125 ---ND------3.11120---ND------0.518121---ND------0.518 122 ---ND------0.518123---ND------0.518124107/124 ---ND------1.04 125 86/87/97/108/119/125 ---ND------3.11126---ND------0.518127---ND------0.518128128/166 ---ND------1.04129129/138/163 ---ND------1.55 130 ---ND------0.518131---ND------0.518132---ND------0.518 133 ---ND------0.518134134/143 ---ND------1.04135135/151 ---ND------1.04 136 ---ND------0.518137---ND------0.518138129/138/163 ---ND------1.55139139/140 ---ND------1.04140139/140 ---ND------1.04141---ND------0.518142---ND------0.518143134/143 ---ND------1.04 144 ---ND------0.518 Page 33 of 60Report No.....10439554_1668_209_DFR Page 52 of 79 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SW010-F005 P180721B_11Lab Sample ID 92391738004 Co-elutions RT ng/L EMLEMPCConcentration ng/LIUPACRatio ng/L 145 ---ND------0.518146---ND------0.518147147/149 ---ND------1.04 148 ---ND------0.518149147/149 ---ND------1.04150---ND------0.518151135/151 ---ND------1.04152---ND------0.518 153 153/168 ---ND------1.04154---ND------0.518155---ND------0.518 156 156/157 ---ND------1.04157156/157 ---ND------1.04158---ND------0.518 159 ---ND------0.518160---ND------0.518161---ND------0.518162---ND------0.518163129/138/163 ---ND------1.55164---ND------0.518165---ND------0.518166128/166 ---ND------1.04 167 ---ND------0.518168153/168 ---ND------1.04169---ND------0.518 170 ---ND------0.518171171/173 ---ND------1.04172---ND------0.518 173 171/173 ---ND------1.04174---ND------0.518175---ND------0.518176---ND------0.518177---ND------0.518 178 ---ND------0.518179---ND------0.518180180/193 ---ND------1.04 181 ---ND------0.518182---ND------0.518183183/185 ---ND------1.04 184 ---ND------0.518185183/185 ---ND------1.04186---ND------0.518187---ND------0.518188---ND------0.518189---ND------0.518190---ND------0.518191---ND------0.518 192 ---ND------0.518 Page 34 of 60Report No.....10439554_1668_209_DFR Page 53 of 79 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SW010-F005 P180721B_11Lab Sample ID 92391738004 Co-elutions RT ng/L EMLEMPCConcentration ng/LIUPACRatio ng/L 193 180/193 ---ND------1.04194---ND------0.776195---ND------0.776 196 ---ND------0.776197197/200 ---ND------1.55198198/199 ---ND------1.55199198/199 ---ND------1.55200197/200 ---ND------1.55 201 ---ND------0.776202---ND------0.776203---ND------0.776 204 ---ND------0.776205---ND------0.776206---ND------0.776 207 ---ND------0.776208---ND------0.776209---ND------0.776 Page 35 of 60Report No.....10439554_1668_209_DFR Page 54 of 79 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SW010-F005 P180721B_11 Sample Analysis Results Lab Sample ID 92391738004 Congener Group Concentration ng/L Total MonochloroBiphenyls ND TotalDichloroBiphenyls ND Total TrichloroBiphenyls ND Total TetrachloroBiphenyls ND TotalPentachloroBiphenyls ND TotalHexachloroBiphenyls ND TotalHeptachloroBiphenyls ND Total Octachloro Biphenyls ND TotalNonachloroBiphenyls ND DecachloroBiphenyls ND Total PCBs ND ND = Not Detected Page 36 of 60Report No.....10439554_1668_209_DFR Page 55 of 79 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Client - PACE Charlotte Client's Sample ID Lab Sample ID Filename Injected ByTotal Amount Extracted% Moisture Dry Weight Extracted ICAL ID CCal Filename(s)Method Blank ID BLANK-63512P180721B_01 P180721B02 NA NA890 mLBAL P180721B_12 92391738005 ABL-SW011-F005 MatrixDilution Collected Received ExtractedAnalyzed 07/22/2018 04:5207/17/2018 13:15 07/14/2018 09:30 07/12/2018 NAWater Method 1668A Polychlorobiphenyl Sample Analysis Results PCB Isomer RT % Recoveryng's Foundng's AddedIUPACRatio LabeledAnalytes13C-2-MoCB 1 3.33 2.09.599 0.796 4013C-4-MoCB 3 3.11 2.012.427 0.967 4813C-2,2'-DiCB 4 1.51 2.012.727 0.887 4413C-4,4'-DiCB 15 1.64 2.019.878 1.27 6313C-2,2',6-TrCB 19 1.09 2.016.583 1.16 5813C-3,4,4'-TrCB 37 1.09 2.027.693 1.58 7913C-2,2',6,6'-TeCB 54 0.84 2.020.197 0.996 5013C-3,4,4',5-TeCB 81 0.78 2.034.826 1.68 8413C-3,3',4,4'-TeCB 77 0.80 2.035.412 1.73 8613C-2,2',4,6,6'-PeCB 104 1.54 2.026.301 1.08 5413C-2,3,3',4,4'-PeCB 105 1.67 2.039.006 1.68 8413C-2,3,4,4',5-PeCB 114 1.67 2.038.319 1.64 8213C-2,3',4,4',5-PeCB 118 1.59 2.037.782 1.67 8313C-2,3',4,4',5'-PeCB 123 1.57 2.037.430 1.61 8113C-3,3',4,4',5-PeCB 126 1.52 2.042.193 1.79 9013C-2,2',4,4',6,6'-HxCB 155 1.26 2.032.327 1.16 5813C-HxCB(156/157)156/157 1.26 4.045.216 3.11 7813C-2,3',4,4',5,5'-HxCB 167 1.25 2.044.043 1.57 7913C-3,3',4,4',5,5'-HxCB 169 1.23 2.048.554 1.68 8413C-2,2',3,4',5,6,6'-HpCB 188 1.08 2.038.252 1.28 6413C-2,3,3',4,4',5,5'-HpCB 189 1.08 2.051.026 1.59 7913C-2,2',3,3',5,5',6,6'-OcCB 202 0.89 2.043.741 1.35 6813C-2,3,3',4,4',5,5',6-OcCB 205 0.89 2.053.095 1.54 7713C-2,2',3,3',4,4',5,5',6-NoCB 206 0.83 2.054.540 1.48 7413C-2,2',3,3',4,5,5',6,6'-NoCB 208 0.75 2.050.487 1.36 6813C--DeCB 209 0.76 2.055.984 1.44 72 CleanupStandards13C-2,4,4'-TrCB 28 1.11 2.023.283 1.57 7913C-2,3,3',5,5'-PeCB 111 1.64 2.035.379 1.49 7413C-2,2',3,3',5,5',6-HpCB 178 0.99 2.041.371 1.47 73 Recovery Standards13C-2,5-DiCB 9 1.57 2.015.193 NA NA13C-2,2',5,5'-TeCB 52 0.76 2.025.295 NA NA13C-2,2',4,5,5'-PeCB 101 1.46 2.032.595 NA NA13C-2,2',3,4,4',5'-HxCB 138 1.22 2.040.951 NA NA13C-2,2',3,3',4,4',5,5'-OcCB 194 0.87 2.052.729 NA NA Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Page 37 of 60Report No.....10439554_1668_209_DFR Page 56 of 79 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SW011-F005 P180721B_12Lab Sample ID 92391738005 Co-elutions RT ng/L EMLEMPCConcentration ng/LIUPACRatio ng/L 1 ---ND------0.2812---ND------0.2813---ND------0.281 4 ---ND------0.2815---ND------0.2816---ND------0.2817---ND------0.2818---ND------0.281 9 ---ND------0.28110---ND------0.28111---ND------2.75 12 12/13 ---ND------0.5621312/13 ---ND------0.56214---ND------0.281 15 ---ND------0.37116---ND------0.28117---ND------0.2811818/30 ---ND------0.56219---ND------0.2812020/28 ---ND------1.452121/33 ---ND------1.5222---ND------1.07 23 ---ND------0.28124---ND------0.28125---ND------0.281 26 26/29 ---ND------0.56227---ND------0.2812820/28 ---ND------1.45 29 26/29 ---ND------0.5623018/30 ---ND------0.56231---ND------1.4632---ND------0.2813321/33 ---ND------1.52 34 ---ND------0.28135---ND------0.28136---ND------0.281 37 ---ND------0.59538---ND------0.28139---ND------0.281 40 40/41/71 ---ND------1.694140/41/71 ---ND------1.6942---ND------0.5624343/73 ---ND------0.5624444/47/65 ---ND------1.694545/51 ---ND------1.1246---ND------0.5624744/47/65 ---ND------1.69 48 ---ND------0.562 Page 38 of 60Report No.....10439554_1668_209_DFR Page 57 of 79 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SW011-F005 P180721B_12Lab Sample ID 92391738005 Co-elutions RT ng/L EMLEMPCConcentration ng/LIUPACRatio ng/L 49 49/69 ---ND------1.125050/53 ---ND------1.125145/51 ---ND------1.12 52 ---ND------1.735350/53 ---ND------1.1254---ND------0.56255---ND------0.56256---ND------0.562 57 ---ND------0.56258---ND------0.5625959/62/75 ---ND------1.69 60 ---ND------0.5626161/70/74/76 ---ND------2.256259/62/75 ---ND------1.69 63 ---ND------0.56264---ND------0.5626544/47/65 ---ND------1.6966---ND------0.94467---ND------0.56268---ND------0.5626949/69 ---ND------1.127061/70/74/76 ---ND------2.25 71 40/41/71 ---ND------1.6972---ND------0.5627343/73 ---ND------0.562 74 61/70/74/76 ---ND------2.257559/62/75 ---ND------1.697661/70/74/76 ---ND------2.25 77 ---ND------0.56278---ND------0.56279---ND------0.56280---ND------0.56281---ND------0.562 82 ---ND------0.56283---ND------0.56284---ND------0.562 85 85/116/117 ---ND------1.698686/87/97/108/119/125 ---ND------3.378786/87/97/108/119/125 ---ND------3.37 88 88/91 ---ND------1.1289---ND------0.5629090/101/113 ---ND------1.699188/91 ---ND------1.1292---ND------0.5629393/98/100/102 ---ND------2.2594---ND------0.56295---ND------1.07 96 ---ND------0.562 Page 39 of 60Report No.....10439554_1668_209_DFR Page 58 of 79 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SW011-F005 P180721B_12Lab Sample ID 92391738005 Co-elutions RT ng/L EMLEMPCConcentration ng/LIUPACRatio ng/L 97 86/87/97/108/119/125 ---ND------3.379893/98/100/102 ---ND------2.2599---ND------0.562 100 93/98/100/102 ---ND------2.2510190/101/113 ---ND------1.6910293/98/100/102 ---ND------2.25103---ND------0.562104---ND------0.562 105 ---ND------0.562106---ND------0.562107107/124 ---ND------1.12 108 86/87/97/108/119/125 ---ND------3.37109---ND------0.562110110/115 ---ND------1.12 111 ---ND------0.562112---ND------0.56211390/101/113 ---ND------1.69114---ND------0.562115110/115 ---ND------1.1211685/116/117 ---ND------1.6911785/116/117 ---ND------1.69118---ND------0.719 119 86/87/97/108/119/125 ---ND------3.37120---ND------0.562121---ND------0.562 122 ---ND------0.562123---ND------0.562124107/124 ---ND------1.12 125 86/87/97/108/119/125 ---ND------3.37126---ND------0.562127---ND------0.562128128/166 ---ND------1.12129129/138/163 ---ND------1.69 130 ---ND------0.562131---ND------0.562132---ND------0.562 133 ---ND------0.562134134/143 ---ND------1.12135135/151 ---ND------1.12 136 ---ND------0.562137---ND------0.562138129/138/163 ---ND------1.69139139/140 ---ND------1.12140139/140 ---ND------1.12141---ND------0.562142---ND------0.562143134/143 ---ND------1.12 144 ---ND------0.562 Page 40 of 60Report No.....10439554_1668_209_DFR Page 59 of 79 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SW011-F005 P180721B_12Lab Sample ID 92391738005 Co-elutions RT ng/L EMLEMPCConcentration ng/LIUPACRatio ng/L 145 ---ND------0.562146---ND------0.562147147/149 ---ND------1.12 148 ---ND------0.562149147/149 ---ND------1.12150---ND------0.562151135/151 ---ND------1.12152---ND------0.562 153 153/168 ---ND------1.12154---ND------0.562155---ND------0.562 156 156/157 ---ND------1.12157156/157 ---ND------1.12158---ND------0.562 159 ---ND------0.562160---ND------0.562161---ND------0.562162---ND------0.562163129/138/163 ---ND------1.69164---ND------0.562165---ND------0.562166128/166 ---ND------1.12 167 ---ND------0.562168153/168 ---ND------1.12169---ND------0.562 170 ---ND------0.562171171/173 ---ND------1.12172---ND------0.562 173 171/173 ---ND------1.12174---ND------0.562175---ND------0.562176---ND------0.562177---ND------0.562 178 ---ND------0.562179---ND------0.562180180/193 ---ND------1.12 181 ---ND------0.562182---ND------0.562183183/185 ---ND------1.12 184 ---ND------0.562185183/185 ---ND------1.12186---ND------0.562187---ND------0.562188---ND------0.562189---ND------0.562190---ND------0.562191---ND------0.562 192 ---ND------0.562 Page 41 of 60Report No.....10439554_1668_209_DFR Page 60 of 79 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SW011-F005 P180721B_12Lab Sample ID 92391738005 Co-elutions RT ng/L EMLEMPCConcentration ng/LIUPACRatio ng/L 193 180/193 ---ND------1.12194---ND------0.843195---ND------0.843 196 ---ND------0.843197197/200 ---ND------1.69198198/199 ---ND------1.69199198/199 ---ND------1.69200197/200 ---ND------1.69 201 ---ND------0.843202---ND------0.843203---ND------0.843 204 ---ND------0.843205---ND------0.843206---ND------0.843 207 ---ND------0.843208---ND------0.843209---ND------0.843 Page 42 of 60Report No.....10439554_1668_209_DFR Page 61 of 79 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SW011-F005 P180721B_12 Sample Analysis Results Lab Sample ID 92391738005 Congener Group Concentration ng/L Total MonochloroBiphenyls ND TotalDichloroBiphenyls ND Total TrichloroBiphenyls ND Total TetrachloroBiphenyls ND TotalPentachloroBiphenyls ND TotalHexachloroBiphenyls ND TotalHeptachloroBiphenyls ND Total Octachloro Biphenyls ND TotalNonachloroBiphenyls ND DecachloroBiphenyls ND Total PCBs ND ND = Not Detected Page 43 of 60Report No.....10439554_1668_209_DFR Page 62 of 79 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Client - PACE Charlotte Client's Sample ID Lab Sample ID Filename Injected ByTotal Amount Extracted% Moisture Dry Weight Extracted ICAL ID CCal Filename(s)Method Blank ID BLANK-63512P180721B_01 P180721B02 NA NA972 mLBAL P180721B_13 92391738006 ABL-SW012-F005 MatrixDilution Collected Received ExtractedAnalyzed 07/22/2018 05:5207/17/2018 13:15 07/14/2018 09:30 07/12/2018 NAWater Method 1668A Polychlorobiphenyl Sample Analysis Results PCB Isomer RT % Recoveryng's Foundng's AddedIUPACRatio LabeledAnalytes13C-2-MoCB 1 3.02 2.09.576 0.743 3713C-4-MoCB 3 2.88 2.012.428 0.937 4713C-2,2'-DiCB 4 1.52 2.012.727 0.857 4313C-4,4'-DiCB 15 1.52 2.019.879 1.19 6013C-2,2',6-TrCB 19 1.02 2.016.548 1.47 7313C-3,4,4'-TrCB 37 1.00 2.027.678 1.35 6713C-2,2',6,6'-TeCB 54 0.84 2.020.198 1.03 5113C-3,4,4',5-TeCB 81 0.86 2.034.810 1.60 8013C-3,3',4,4'-TeCB 77 0.80 2.035.414 1.53 7713C-2,2',4,6,6'-PeCB 104 1.62 2.026.286 1.07 5413C-2,3,3',4,4'-PeCB 105 1.53 2.038.991 1.56 7813C-2,3,4,4',5-PeCB 114 1.48 2.038.320 1.55 7813C-2,3',4,4',5-PeCB 118 1.51 2.037.767 1.53 7713C-2,3',4,4',5'-PeCB 123 1.56 2.037.415 1.56 7813C-3,3',4,4',5-PeCB 126 1.75 2.042.177 1.62 8113C-2,2',4,4',6,6'-HxCB 155 1.23 2.032.328 1.10 5513C-HxCB(156/157)156/157 1.34 4.045.218 2.93 7313C-2,3',4,4',5,5'-HxCB 167 1.23 2.044.028 1.45 7313C-3,3',4,4',5,5'-HxCB 169 1.27 2.048.538 1.56 7813C-2,2',3,4',5,6,6'-HpCB 188 1.05 2.038.220 1.23 6213C-2,3,3',4,4',5,5'-HpCB 189 1.08 2.051.028 1.52 7613C-2,2',3,3',5,5',6,6'-OcCB 202 0.84 2.043.725 1.30 6513C-2,3,3',4,4',5,5',6-OcCB 205 0.85 2.053.097 1.46 7313C-2,2',3,3',4,4',5,5',6-NoCB 206 0.79 2.054.520 1.41 7113C-2,2',3,3',4,5,5',6,6'-NoCB 208 0.82 2.050.489 1.32 6613C--DeCB 209 0.70 2.055.985 1.36 68 CleanupStandards13C-2,4,4'-TrCB 28 1.07 2.023.267 1.56 7813C-2,3,3',5,5'-PeCB 111 1.66 2.035.381 1.57 7913C-2,2',3,3',5,5',6-HpCB 178 1.05 2.041.372 1.50 75 Recovery Standards13C-2,5-DiCB 9 1.56 2.015.182 NA NA13C-2,2',5,5'-TeCB 52 0.81 2.025.280 NA NA13C-2,2',4,5,5'-PeCB 101 1.49 2.032.580 NA NA13C-2,2',3,4,4',5'-HxCB 138 1.30 2.040.953 NA NA13C-2,2',3,3',4,4',5,5'-OcCB 194 0.92 2.052.730 NA NA Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Page 44 of 60Report No.....10439554_1668_209_DFR Page 63 of 79 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SW012-F005 P180721B_13Lab Sample ID 92391738006 Co-elutions RT ng/L EMLEMPCConcentration ng/LIUPACRatio ng/L 1 ---ND------0.2572---ND------0.2573---ND------0.257 4 ---ND------0.2575---ND------0.2576---ND------0.2577---ND------0.2578---ND------0.257 9 ---ND------0.25710---ND------0.25711---ND------2.52 12 12/13 ---ND------0.5151312/13 ---ND------0.51514---ND------0.257 15 ---ND------0.34016---ND------0.25717---ND------0.2571818/30 ---ND------0.51519---ND------0.2572020/28 ---ND------1.332121/33 ---ND------1.3922---ND------0.978 23 ---ND------0.25724---ND------0.25725---ND------0.257 26 26/29 ---ND------0.51527---ND------0.2572820/28 ---ND------1.33 29 26/29 ---ND------0.5153018/30 ---ND------0.51531---ND------1.3432---ND------0.2573321/33 ---ND------1.39 34 ---ND------0.25735---ND------0.25736---ND------0.257 37 ---ND------0.54538---ND------0.25739---ND------0.257 40 40/41/71 ---ND------1.544140/41/71 ---ND------1.5442---ND------0.5154343/73 ---ND------0.5154444/47/65 ---ND------1.544545/51 ---ND------1.0346---ND------0.5154744/47/65 ---ND------1.54 48 ---ND------0.515 Page 45 of 60Report No.....10439554_1668_209_DFR Page 64 of 79 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SW012-F005 P180721B_13Lab Sample ID 92391738006 Co-elutions RT ng/L EMLEMPCConcentration ng/LIUPACRatio ng/L 49 49/69 ---ND------1.035050/53 ---ND------1.035145/51 ---ND------1.03 52 ---ND------1.585350/53 ---ND------1.0354---ND------0.51555---ND------0.51556---ND------0.515 57 ---ND------0.51558---ND------0.5155959/62/75 ---ND------1.54 60 ---ND------0.5156161/70/74/76 ---ND------2.066259/62/75 ---ND------1.54 63 ---ND------0.51564---ND------0.5156544/47/65 ---ND------1.5466---ND------0.86467---ND------0.51568---ND------0.5156949/69 ---ND------1.037061/70/74/76 ---ND------2.06 71 40/41/71 ---ND------1.5472---ND------0.5157343/73 ---ND------0.515 74 61/70/74/76 ---ND------2.067559/62/75 ---ND------1.547661/70/74/76 ---ND------2.06 77 ---ND------0.51578---ND------0.51579---ND------0.51580---ND------0.51581---ND------0.515 82 ---ND------0.51583---ND------0.51584---ND------0.515 85 85/116/117 ---ND------1.548686/87/97/108/119/125 ---ND------3.098786/87/97/108/119/125 ---ND------3.09 88 88/91 ---ND------1.0389---ND------0.5159090/101/113 ---ND------1.549188/91 ---ND------1.0392---ND------0.5159393/98/100/102 ---ND------2.0694---ND------0.51595---ND------0.978 96 ---ND------0.515 Page 46 of 60Report No.....10439554_1668_209_DFR Page 65 of 79 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SW012-F005 P180721B_13Lab Sample ID 92391738006 Co-elutions RT ng/L EMLEMPCConcentration ng/LIUPACRatio ng/L 97 86/87/97/108/119/125 ---ND------3.099893/98/100/102 ---ND------2.0699---ND------0.515 100 93/98/100/102 ---ND------2.0610190/101/113 ---ND------1.5410293/98/100/102 ---ND------2.06103---ND------0.515104---ND------0.515 105 ---ND------0.515106---ND------0.515107107/124 ---ND------1.03 108 86/87/97/108/119/125 ---ND------3.09109---ND------0.515110110/115 ---ND------1.03 111 ---ND------0.515112---ND------0.51511390/101/113 ---ND------1.54114---ND------0.515115110/115 ---ND------1.0311685/116/117 ---ND------1.5411785/116/117 ---ND------1.54118---ND------0.659 119 86/87/97/108/119/125 ---ND------3.09120---ND------0.515121---ND------0.515 122 ---ND------0.515123---ND------0.515124107/124 ---ND------1.03 125 86/87/97/108/119/125 ---ND------3.09126---ND------0.515127---ND------0.515128128/166 ---ND------1.03129129/138/163 ---ND------1.54 130 ---ND------0.515131---ND------0.515132---ND------0.515 133 ---ND------0.515134134/143 ---ND------1.03135135/151 ---ND------1.03 136 ---ND------0.515137---ND------0.515138129/138/163 ---ND------1.54139139/140 ---ND------1.03140139/140 ---ND------1.03141---ND------0.515142---ND------0.515143134/143 ---ND------1.03 144 ---ND------0.515 Page 47 of 60Report No.....10439554_1668_209_DFR Page 66 of 79 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SW012-F005 P180721B_13Lab Sample ID 92391738006 Co-elutions RT ng/L EMLEMPCConcentration ng/LIUPACRatio ng/L 145 ---ND------0.515146---ND------0.515147147/149 ---ND------1.03 148 ---ND------0.515149147/149 ---ND------1.03150---ND------0.515151135/151 ---ND------1.03152---ND------0.515 153 153/168 ---ND------1.03154---ND------0.515155---ND------0.515 156 156/157 ---ND------1.03157156/157 ---ND------1.03158---ND------0.515 159 ---ND------0.515160---ND------0.515161---ND------0.515162---ND------0.515163129/138/163 ---ND------1.54164---ND------0.515165---ND------0.515166128/166 ---ND------1.03 167 ---ND------0.515168153/168 ---ND------1.03169---ND------0.515 170 ---ND------0.515171171/173 ---ND------1.03172---ND------0.515 173 171/173 ---ND------1.03174---ND------0.515175---ND------0.515176---ND------0.515177---ND------0.515 178 ---ND------0.515179---ND------0.515180180/193 ---ND------1.03 181 ---ND------0.515182---ND------0.515183183/185 ---ND------1.03 184 ---ND------0.515185183/185 ---ND------1.03186---ND------0.515187---ND------0.515188---ND------0.515189---ND------0.515190---ND------0.515191---ND------0.515 192 ---ND------0.515 Page 48 of 60Report No.....10439554_1668_209_DFR Page 67 of 79 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SW012-F005 P180721B_13Lab Sample ID 92391738006 Co-elutions RT ng/L EMLEMPCConcentration ng/LIUPACRatio ng/L 193 180/193 ---ND------1.03194---ND------0.772195---ND------0.772 196 ---ND------0.772197197/200 ---ND------1.54198198/199 ---ND------1.54199198/199 ---ND------1.54200197/200 ---ND------1.54 201 ---ND------0.772202---ND------0.772203---ND------0.772 204 ---ND------0.772205---ND------0.772206---ND------0.772 207 ---ND------0.772208---ND------0.772209---ND------0.772 Page 49 of 60Report No.....10439554_1668_209_DFR Page 68 of 79 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SW012-F005 P180721B_13 Sample Analysis Results Lab Sample ID 92391738006 Congener Group Concentration ng/L Total MonochloroBiphenyls ND TotalDichloroBiphenyls ND Total TrichloroBiphenyls ND Total TetrachloroBiphenyls ND TotalPentachloroBiphenyls ND TotalHexachloroBiphenyls ND TotalHeptachloroBiphenyls ND Total Octachloro Biphenyls ND TotalNonachloroBiphenyls ND DecachloroBiphenyls ND Total PCBs ND ND = Not Detected Page 50 of 60Report No.....10439554_1668_209_DFR Page 69 of 79 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Method 1668A Polychlorobiphenyl Lab Sample ID Injected ByFilename Total Amount Extracted ICAL ID CCal Filename(s) BLANK-63512 P180721B_06BAL1040 mL P180721B02 P180721B_01 MatrixExtracted Analyzed Water (QC Matrix)07/17/2018 13:15 07/21/2018 22:54 Blank Analysis Results Dilution NA PCB Isomer RT % Recoveryng's Foundng's AddedIUPACRatio Labeled Analytes13C-2-MoCB 1 2.94 2.09.599 1.30 6513C-4-MoCB 3 2.84 2.012.439 1.42 7113C-2,2'-DiCB 4 1.54 2.012.738 1.28 6413C-4,4'-DiCB 15 1.52 2.019.890 1.48 7413C-2,2',6-TrCB 19 0.96 2.016.559 1.91 9613C-3,4,4'-TrCB 37 1.17 2.027.710 1.92 9613C-2,2',6,6'-TeCB 54 0.89 2.020.197 1.45 73 13C-3,4,4',5-TeCB 81 0.84 2.034.825 1.81 9013C-3,3',4,4'-TeCB 77 0.85 2.035.429 1.79 9013C-2,2',4,6,6'-PeCB 104 1.52 2.026.318 1.28 6413C-2,3,3',4,4'-PeCB 105 1.60 2.039.006 1.88 9413C-2,3,4,4',5-PeCB 114 1.64 2.038.335 1.78 8913C-2,3',4,4',5-PeCB 118 1.51 2.037.782 1.85 9213C-2,3',4,4',5'-PeCB 123 1.49 2.037.446 1.85 9313C-3,3',4,4',5-PeCB 126 1.59 2.042.192 1.97 9913C-2,2',4,4',6,6'-HxCB 155 1.27 2.032.327 1.27 6413C-HxCB (156/157)156/157 1.31 4.045.250 3.34 8413C-2,3',4,4',5,5'-HxCB 167 1.28 2.044.042 1.68 8413C-3,3',4,4',5,5'-HxCB 169 1.29 2.048.536 1.86 9313C-2,2',3,4',5,6,6'-HpCB 188 1.02 2.038.251 1.47 7413C-2,3,3',4,4',5,5'-HpCB 189 1.07 2.051.047 1.80 9013C-2,2',3,3',5,5',6,6'-OcCB 202 0.95 2.043.740 1.55 7713C-2,3,3',4,4',5,5',6-OcCB 205 0.89 2.053.116 1.74 8713C-2,2',3,3',4,4',5,5',6-NoCB 206 0.76 2.054.539 1.60 8013C-2,2',3,3',4,5,5',6,6'-NoCB 208 0.84 2.050.508 1.56 7813C--DeCB 209 0.63 2.055.983 1.62 81 Cleanup Standards13C-2,4,4'-TrCB 28 1.15 2.023.283 2.23 11113C-2,3,3',5,5'-PeCB 111 1.61 2.035.396 1.82 9113C-2,2',3,3',5,5',6-HpCB 178 1.05 2.041.387 1.75 87 Recovery Standards13C-2,5-DiCB 9 1.60 2.015.193 NA NA13C-2,2',5,5'-TeCB 52 0.75 2.025.295 NA NA13C-2,2',4,5,5'-PeCB 101 1.62 2.032.595 NA NA13C-2,2',3,4,4',5'-HxCB 138 1.25 2.040.968 NA NA13C-2,2',3,3',4,4',5,5'-OcCB 194 0.94 2.052.728 NA NA Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Page 51 of 60Report No.....10439554_1668_209_DFR Page 70 of 79 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits ng/L = Nanograms per liter ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference Method 1668A Polychlorobiphenyl Lab Sample ID Filename BLANK-63512 P180721B_06 Blank Analysis Results Co-elutions RT ng/L EMLEMPCConcentration ng/LIUPACRatio ng/L 1 ---ND------0.2412---ND------0.2413---ND------0.2414---ND------0.2415---ND------0.2416---ND------0.2417---ND------0.2418---ND------0.2419---ND------0.24110---ND------0.24111---ND------2.371212/13 ---ND------0.4831312/13 ---ND------0.48314---ND------0.24115---ND------0.24116---ND------0.24117---ND------0.2411818/30 ---ND------0.483 19 ---ND------0.2412020/28 ---ND------1.252121/33 ---ND------1.3022---ND------0.91823---ND------0.24124---ND------0.24125---ND------0.2412626/29 ---ND------0.48327---ND------0.2412820/28 ---ND------1.252926/29 ---ND------0.4833018/30 ---ND------0.48331---ND------1.2632---ND------0.2413321/33 ---ND------1.3034---ND------0.24135---ND------0.24136---ND------0.24137---ND------0.51238---ND------0.24139---ND------0.2414040/41/71 ---ND------1.454140/41/71 ---ND------1.4542---ND------0.4834343/73 ---ND------0.483 44 44/47/65 ---ND------1.454545/51 ---ND------0.966 Page 52 of 60Report No.....10439554_1668_209_DFR Page 71 of 79 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits ng/L = Nanograms per liter ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference Method 1668A Polychlorobiphenyl Lab Sample ID Filename BLANK-63512 P180721B_06 Blank Analysis Results Co-elutions RT ng/L EMLEMPCConcentration ng/LIUPACRatio ng/L 46 ---ND------0.4834744/47/65 ---ND------1.4548---ND------0.4834949/69 ---ND------0.9665050/53 ---ND------0.9665145/51 ---ND------0.96652---ND------1.495350/53 ---ND------0.96654---ND------0.48355---ND------0.48356---ND------0.48357---ND------0.48358---ND------0.4835959/62/75 ---ND------1.4560---ND------0.4836161/70/74/76 ---ND------1.936259/62/75 ---ND------1.4563---ND------0.483 64 ---ND------0.4836544/47/65 ---ND------1.4566---ND------0.81167---ND------0.48368---ND------0.4836949/69 ---ND------0.9667061/70/74/76 ---ND------1.937140/41/71 ---ND------1.4572---ND------0.4837343/73 ---ND------0.4837461/70/74/76 ---ND------1.937559/62/75 ---ND------1.457661/70/74/76 ---ND------1.9377---ND------0.48378---ND------0.48379---ND------0.48380---ND------0.48381---ND------0.48382---ND------0.48383---ND------0.48384---ND------0.4838585/116/117 ---ND------1.458686/87/97/108/119/125 ---ND------2.908786/87/97/108/119/125 ---ND------2.908888/91 ---ND------0.966 89 ---ND------0.4839090/101/113 ---ND------1.45 Page 53 of 60Report No.....10439554_1668_209_DFR Page 72 of 79 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits ng/L = Nanograms per liter ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference Method 1668A Polychlorobiphenyl Lab Sample ID Filename BLANK-63512 P180721B_06 Blank Analysis Results Co-elutions RT ng/L EMLEMPCConcentration ng/LIUPACRatio ng/L 91 88/91 ---ND------0.96692---ND------0.4839393/98/100/102 ---ND------1.9394---ND------0.48395---ND------0.91896---ND------0.4839786/87/97/108/119/125 ---ND------2.909893/98/100/102 ---ND------1.9399---ND------0.48310093/98/100/102 ---ND------1.9310190/101/113 ---ND------1.4510293/98/100/102 ---ND------1.93103---ND------0.483104---ND------0.483105---ND------0.483106---ND------0.483107107/124 ---ND------0.96610886/87/97/108/119/125 ---ND------2.90 109 ---ND------0.483110110/115 ---ND------0.966111---ND------0.483112---ND------0.48311390/101/113 ---ND------1.45114---ND------0.483115110/115 ---ND------0.96611685/116/117 ---ND------1.4511785/116/117 ---ND------1.45118---ND------0.61811986/87/97/108/119/125 ---ND------2.90120---ND------0.483121---ND------0.483122---ND------0.483123---ND------0.483124107/124 ---ND------0.96612586/87/97/108/119/125 ---ND------2.90126---ND------0.483127---ND------0.483128128/166 ---ND------0.966129129/138/163 ---ND------1.45130---ND------0.483131---ND------0.483132---ND------0.483133---ND------0.483 134 134/143 ---ND------0.966135135/151 ---ND------0.966 Page 54 of 60Report No.....10439554_1668_209_DFR Page 73 of 79 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits ng/L = Nanograms per liter ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference Method 1668A Polychlorobiphenyl Lab Sample ID Filename BLANK-63512 P180721B_06 Blank Analysis Results Co-elutions RT ng/L EMLEMPCConcentration ng/LIUPACRatio ng/L 136 ---ND------0.483137---ND------0.483138129/138/163 ---ND------1.45139139/140 ---ND------0.966140139/140 ---ND------0.966141---ND------0.483142---ND------0.483143134/143 ---ND------0.966144---ND------0.483145---ND------0.483146---ND------0.483147147/149 ---ND------0.966148---ND------0.483149147/149 ---ND------0.966150---ND------0.483151135/151 ---ND------0.966152---ND------0.483153153/168 ---ND------0.966 154 ---ND------0.483155---ND------0.483156156/157 ---ND------0.966157156/157 ---ND------0.966158---ND------0.483159---ND------0.483160---ND------0.483161---ND------0.483162---ND------0.483163129/138/163 ---ND------1.45164---ND------0.483165---ND------0.483166128/166 ---ND------0.966167---ND------0.483168153/168 ---ND------0.966169---ND------0.483170---ND------0.483171171/173 ---ND------0.966172---ND------0.483173171/173 ---ND------0.966174---ND------0.483175---ND------0.483176---ND------0.483177---ND------0.483178---ND------0.483 179 ---ND------0.483180180/193 ---ND------0.966 Page 55 of 60Report No.....10439554_1668_209_DFR Page 74 of 79 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits ng/L = Nanograms per liter ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference Method 1668A Polychlorobiphenyl Lab Sample ID Filename BLANK-63512 P180721B_06 Blank Analysis Results Co-elutions RT ng/L EMLEMPCConcentration ng/LIUPACRatio ng/L 181 ---ND------0.483182---ND------0.483183183/185 ---ND------0.966184---ND------0.483185183/185 ---ND------0.966186---ND------0.483187---ND------0.483188---ND------0.483189---ND------0.483190---ND------0.483191---ND------0.483192---ND------0.483193180/193 ---ND------0.966194---ND------0.724195---ND------0.724196---ND------0.724197197/200 ---ND------1.45198198/199 ---ND------1.45 199 198/199 ---ND------1.45200197/200 ---ND------1.45201---ND------0.724202---ND------0.724203---ND------0.724204---ND------0.724205---ND------0.724206---ND------0.724207---ND------0.724208---ND------0.724209---ND------0.724 Page 56 of 60Report No.....10439554_1668_209_DFR Page 75 of 79 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Method 1668A Polychlorobiphenyl Client Sample ID Filename CBLKSY P180721B_06 Blank Analysis Results Lab Sample ID BLANK-63512 Congener Group Concentration ng/L Total MonochloroBiphenyls ND TotalDichloroBiphenyls ND Total TrichloroBiphenyls ND Total TetrachloroBiphenyls ND TotalPentachloroBiphenyls ND TotalHexachloroBiphenyls ND TotalHeptachloroBiphenyls ND Total Octachloro Biphenyls ND TotalNonachloroBiphenyls ND DecachloroBiphenyls ND Total PCBs ND ND = Not Detected Page 57 of 60Report No.....10439554_1668_209_DFR Page 76 of 79 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Method 1668A Polychlorobiphenyls Lab Sample ID Injected By FilenameTotal Amount Extracted ICAL ID CCal Filename(s) LCS-63513P180721B_03 BAL 945 mL P180721B02 P180721B_01 MatrixDilution Extracted Analyzed Water (QC Matrix) 07/17/2018 13:15 07/21/2018 19:55 NA Method Blank ID BLANK-63512 Laboratory Control Spike Analysis Results PCB Spiked Found Spiked Found % RecoveryIsomer(ng)(ng) % Recovery(ng)(ng) Native Analytes Labeled Analytes 1 1.0 0.996 2.0 0.992 50100 3 1.0 0.978 2.0 1.06 539841.0 1.07 2.0 0.945 47107151.0 1.03 2.0 1.12 56103 19 1.0 0.953 2.0 1.07 5395 37 1.0 0.813 2.0 1.35 6881 54 1.0 0.932 2.0 0.963 4893811.0 0.870 2.0 1.45 7387771.0 0.928 2.0 1.35 6793 104 1.0 0.985 2.0 0.926 4698 105 1.0 0.923 2.0 1.37 6992 114 1.0 1.01 2.0 1.32 661011181.0 0.968 2.0 1.36 68971231.0 0.959 2.0 1.33 6796 126 1.0 0.977 2.0 1.43 7298 155 1.0 0.921 2.0 0.950 4892 156/157 2.0 1.86 4.0 2.54 63931671.0 0.954 2.0 1.24 62951691.0 0.944 2.0 1.43 7194 188 1.0 1.00 2.0 0.960 48100 189 1.0 1.01 2.0 1.30 65101 202 1.0 0.991 2.0 1.00 50992051.0 1.03 2.0 1.20 601032061.0 1.03 2.0 1.13 56103 208 1.0 0.993 2.0 1.06 5399 209 1.0 1.05 2.0 1.08 54105 R =Recovery outside of method 1668A control limits Nn =Result obtained from alternate analysis ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion ng = Nanograms I=Interference Page 58 of 60Report No.....10439554_1668_209_DFR Page 77 of 79 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Method 1668A Polychlorobiphenyls Lab Sample ID Injected By FilenameTotal Amount Extracted ICAL ID CCal Filename(s) LCSD-63514P180721B_04 BAL 959 mL P180721B02 P180721B_01 MatrixDilution Extracted Analyzed Water (QC Matrix) 07/17/2018 13:15 07/21/2018 20:54 NA Method Blank ID BLANK-63512 Laboratory Control Spike Analysis Results PCB Spiked Found Spiked Found % RecoveryIsomer(ng)(ng) % Recovery(ng)(ng) Native Analytes Labeled Analytes 1 1.0 1.04 2.0 1.11 55104 3 1.0 1.04 2.0 1.12 5610441.0 1.13 2.0 0.983 49113151.0 1.09 2.0 1.15 57109 19 1.0 0.903 2.0 1.23 6190 37 1.0 0.939 2.0 1.11 6394 I 54 1.0 0.903 2.0 1.04 5290811.0 0.914 2.0 1.44 7291771.0 0.968 2.0 1.33 6797 104 1.0 0.991 2.0 1.00 5099 105 1.0 1.01 2.0 1.41 71101 114 1.0 1.02 2.0 1.42 711021181.0 0.938 2.0 1.45 73941231.0 0.953 2.0 1.45 7295 126 1.0 0.969 2.0 1.56 7897 155 1.0 1.04 2.0 0.987 49104 156/157 2.0 2.03 4.0 2.67 671021671.0 0.986 2.0 1.36 68991691.0 0.931 2.0 1.49 7493 188 1.0 1.01 2.0 1.13 56101 189 1.0 0.995 2.0 1.51 75100 202 1.0 0.961 2.0 1.19 60962051.0 1.02 2.0 1.33 671022061.0 1.07 2.0 1.26 63107 208 1.0 0.921 2.0 1.27 6392 209 1.0 0.944 2.0 1.20 6094 R =Recovery outside of method 1668A control limits Nn =Result obtained from alternate analysis ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion ng = Nanograms I=Interference Page 59 of 60Report No.....10439554_1668_209_DFR Page 78 of 79 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Client Spike 1 ID Spike 1 Filename P180721B_03 LCS-63513 PACE Charlotte Spike Recovery Relative Percent Difference (RPD) Results Spike 2 ID Spike 2 Filename P180721B_04 LCSD-63514 Method 1668A Spike 1 Spike 2 Compound %REC %REC %RPDIUPAC 2-MoCB 100 104 3.914-MoCB 98 104 5.932,2'-DiCB 107 113 5.544,4'-DiCB 103 109 5.7152,2',6-TrCB 95 90 5.4193,4,4'-TrCB 81 94 14.9372,2',6,6'-TeCB 93 90 3.3543,3',4,4'-TeCB 93 97 4.2773,4,4',5-TeCB 87 91 4.5812,2',4,6,6'-PeCB 98 99 1.01042,3,3',4,4'-PeCB 92 101 9.31052,3,4,4',5-PeCB 101 102 1.01142,3',4,4',5-PeCB 97 94 3.11182,3',4,4',5'-PeCB 96 95 1.01233,3',4,4',5-PeCB 98 97 1.01262,2',4,4',6,6'-HxCB 92 104 12.2155(156/157)93 102 9.2156/1572,3',4,4',5,5'-HxCB 95 99 4.11673,3',4,4',5,5'-HxCB 94 93 1.11692,2',3,4',5,6,6'-HpCB 100 101 1.01882,3,3',4,4',5,5'-HpCB 101 100 1.01892,2',3,3',5,5',6,6'-OcCB 99 96 3.12022,3,3',4,4',5,5',6-OcCB 103 102 1.0205 2,2',3,3',4,4',5,5',6-NoCB 103 107 3.82062,2',3,3',4,5,5',6,6'-NoCB 99 92 7.3208Decachlorobiphenyl1059411.1209 %REC =Percent Recovered RPD =The difference between the two values dividedby the meanvalue Page 60 of 60Report No.....10439554_1668_209_DFR Page 79 of 79 #=CL# August 10, 2018 LIMS USE: FR - MICHAEL WORDEN LIMS OBJECT ID: 92391708 92391708 Project: Pace Project No.: RE: Michael W. Worden Environeering, Inc. 16100 Cairnway Suite 320 Houston, TX 77084 Little Mountain Creek SW PPL Dear Michael Worden: Enclosed are the analytical results for sample(s) received by the laboratory on July 12, 2018. The results relate only to the samples included in this report. Results reported herein conform to the most current, applicable TNI/NELAC standards and the laboratory's Quality Assurance Manual, where applicable, unless otherwise noted in the body of the report. Some analyses have been subcontracted outside of the Pace Network. The subcontracted laboratory report has been attached. This revision was issued on 8/10/18 to include 2,2'-oxybix(1-chloropropane) in the semi-volatile fraction. If you have any questions concerning this report, please feel free to contact me. Sincerely, Nicole Gasiorowski nicole.gasiorowski@pacelabs.com Project Manager (704)875-9092 Enclosures REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 1 of 61 #=CP# CERTIFICATIONS Pace Project No.: Project: 92391708 Little Mountain Creek SW PPL Charlotte Certification IDs 9800 Kincey Ave. Ste 100, Huntersville, NC 28078 Louisiana/NELAP Certification # LA170028 North Carolina Drinking Water Certification #: 37706 North Carolina Field Services Certification #: 5342 North Carolina Wastewater Certification #: 12 South Carolina Certification #: 99006001 Florida/NELAP Certification #: E87627 Kentucky UST Certification #: 84 Virginia/VELAP Certification #: 460221 Asheville Certification IDs 2225 Riverside Drive, Asheville, NC 28804 Florida/NELAP Certification #: E87648 Massachusetts Certification #: M-NC030 North Carolina Drinking Water Certification #: 37712 North Carolina Wastewater Certification #: 40 South Carolina Certification #: 99030001 Virginia/VELAP Certification #: 460222 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 2 of 61 #=SS# SAMPLE SUMMARY Pace Project No.: Project: 92391708 Little Mountain Creek SW PPL Lab ID Sample ID Matrix Date Collected Date Received 92391708001 ABL-SW008-F005 Water 07/12/18 07:10 07/12/18 12:30 92391708002 ABL-SW008-D005 Water 07/12/18 07:30 07/12/18 12:30 92391708003 ABL-SW012-F005 Water 07/12/18 09:55 07/12/18 12:30 92391708004 ABL-TB001-F005 Water 07/12/18 00:00 07/12/18 12:30 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 3 of 61 #=SA# SAMPLE ANALYTE COUNT Pace Project No.: Project: 92391708 Little Mountain Creek SW PPL Lab ID Sample ID Method Analytes Reported LaboratoryAnalysts 92391708001 ABL-SW008-F005 EPA 608.3 27 PASI-CNU1 EPA 200.7 Rev 4.4 1994 12 PASI-ASH1 EPA 245.1 Rev 3.0 1994 1 PASI-AJMW1 EPA 625.1 61 PASI-CPKS EPA 624 37 PASI-CGAW EPA 420.4 Rev 1.0 1993 1 PASI-ADMN SM 4500-CN-E-2011 1 PASI-ACJH1 92391708002 ABL-SW008-D005 EPA 608.3 27 PASI-CNU1 EPA 200.7 Rev 4.4 1994 12 PASI-ASH1 EPA 245.1 Rev 3.0 1994 1 PASI-AJMW1 EPA 625.1 61 PASI-CPKS EPA 624 37 PASI-CGAW EPA 420.4 Rev 1.0 1993 1 PASI-ADMN SM 4500-CN-E-2011 1 PASI-ACJH1 92391708003 ABL-SW012-F005 EPA 608.3 27 PASI-CNU1 EPA 200.7 Rev 4.4 1994 12 PASI-ASH1 EPA 245.1 Rev 3.0 1994 1 PASI-AJMW1 EPA 625.1 61 PASI-CPKS EPA 624 37 PASI-CGAW EPA 420.4 Rev 1.0 1993 1 PASI-ADMN SM 4500-CN-E-2011 1 PASI-ABRJ 92391708004 ABL-TB001-F005 EPA 624 37 PASI-CGAW REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 4 of 61 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92391708 Little Mountain Creek SW PPL Sample:ABL-SW008-F005 Lab ID:92391708001 Collected:07/12/18 07:10 Received:07/12/18 12:30 Matrix:Water Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 608.3 Preparation Method: EPA 608.3608 PCB Pest RVE Aldrin ND ug/L 07/19/18 17:16 309-00-207/18/18 23:580.050 0.050 1 alpha-BHC ND ug/L 07/19/18 17:16 319-84-607/18/18 23:580.050 0.050 1 beta-BHC ND ug/L 07/19/18 17:16 319-85-707/18/18 23:580.050 0.050 1 delta-BHC ND ug/L 07/19/18 17:16 319-86-807/18/18 23:580.050 0.050 1 gamma-BHC (Lindane)ND ug/L 07/19/18 17:16 58-89-907/18/18 23:580.050 0.050 1 Chlordane (Technical)ND ug/L 07/19/18 17:16 57-74-907/18/18 23:580.50 0.50 1 4,4'-DDD ND ug/L 07/19/18 17:16 72-54-807/18/18 23:580.050 0.050 1 4,4'-DDE ND ug/L 07/19/18 17:16 72-55-907/18/18 23:580.050 0.050 1 4,4'-DDT ND ug/L 07/19/18 17:16 50-29-307/18/18 23:580.050 0.050 1 Dieldrin ND ug/L 07/19/18 17:16 60-57-107/18/18 23:580.050 0.050 1 Endosulfan I ND ug/L 07/19/18 17:16 959-98-807/18/18 23:580.050 0.050 1 Endosulfan II ND ug/L 07/19/18 17:16 33213-65-907/18/18 23:580.050 0.050 1 Endosulfan sulfate ND ug/L 07/19/18 17:16 1031-07-807/18/18 23:580.050 0.050 1 Endrin ND ug/L 07/19/18 17:16 72-20-807/18/18 23:580.050 0.050 1 Endrin aldehyde ND ug/L 07/19/18 17:16 7421-93-407/18/18 23:580.050 0.050 1 Heptachlor ND ug/L 07/19/18 17:16 76-44-807/18/18 23:580.050 0.050 1 Heptachlor epoxide ND ug/L 07/19/18 17:16 1024-57-307/18/18 23:580.050 0.050 1 PCB-1016 (Aroclor 1016)ND ug/L 07/19/18 17:16 12674-11-207/18/18 23:580.50 0.50 1 PCB-1221 (Aroclor 1221)ND ug/L 07/19/18 17:16 11104-28-207/18/18 23:580.50 0.50 1 PCB-1232 (Aroclor 1232)ND ug/L 07/19/18 17:16 11141-16-507/18/18 23:580.50 0.50 1 PCB-1242 (Aroclor 1242)ND ug/L 07/19/18 17:16 53469-21-907/18/18 23:580.50 0.50 1 PCB-1248 (Aroclor 1248)ND ug/L 07/19/18 17:16 12672-29-607/18/18 23:580.50 0.50 1 PCB-1254 (Aroclor 1254)ND ug/L 07/19/18 17:16 11097-69-107/18/18 23:580.50 0.50 1 PCB-1260 (Aroclor 1260)ND ug/L 07/19/18 17:16 11096-82-507/18/18 23:580.50 0.50 1 Toxaphene ND ug/L 07/19/18 17:16 8001-35-207/18/18 23:580.50 0.50 1 Surrogates Tetrachloro-m-xylene (S)45 %07/19/18 17:16 877-09-8 S207/18/18 23:5860-140 1 Decachlorobiphenyl (S)53 %07/19/18 17:16 2051-24-3 S207/18/18 23:5860-140 1 Analytical Method: EPA 200.7 Rev 4.4 1994 Preparation Method: EPA 200.7 Rev 4.4 1994200.7 MET ICP Antimony ND ug/L 07/14/18 03:34 7440-36-007/13/18 05:205.0 3.9 1 Arsenic ND ug/L 07/14/18 03:34 7440-38-207/13/18 05:2010.0 5.0 1 Beryllium ND ug/L 07/14/18 03:34 7440-41-707/13/18 05:201.0 0.050 1 Cadmium ND ug/L 07/14/18 03:34 7440-43-907/13/18 05:201.0 0.50 1 Chromium ND ug/L 07/14/18 03:34 7440-47-307/13/18 05:205.0 2.5 1 Copper ND ug/L 07/14/18 03:34 7440-50-807/13/18 05:205.0 2.5 1 Lead ND ug/L 07/14/18 03:34 7439-92-107/13/18 05:205.0 2.5 1 Nickel ND ug/L 07/14/18 03:34 7440-02-007/13/18 05:205.0 2.5 1 Selenium ND ug/L 07/14/18 03:34 7782-49-207/13/18 05:2010.0 5.0 1 Silver ND ug/L 07/14/18 03:34 7440-22-407/13/18 05:205.0 2.5 1 Thallium ND ug/L 07/14/18 03:34 7440-28-007/13/18 05:2010.0 5.0 1 Zinc ND ug/L 07/14/18 03:34 7440-66-607/13/18 05:2010.0 2.5 1 Analytical Method: EPA 245.1 Rev 3.0 1994 Preparation Method: EPA 245.1 Rev 3.0 1994245.1 Mercury Mercury ND ug/L 07/16/18 09:38 7439-97-607/13/18 14:500.20 0.070 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 08/10/2018 07:37 AM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 5 of 61 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92391708 Little Mountain Creek SW PPL Sample:ABL-SW008-F005 Lab ID:92391708001 Collected:07/12/18 07:10 Received:07/12/18 12:30 Matrix:Water Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 625.1 Preparation Method: EPA 625.1625 MSSV Acenaphthene ND ug/L 07/19/18 10:32 83-32-907/12/18 20:275.0 0.25 1 Acenaphthylene ND ug/L 07/19/18 10:32 208-96-807/12/18 20:275.0 0.21 1 Anthracene ND ug/L 07/19/18 10:32 120-12-707/12/18 20:275.0 0.14 1 Benzidine ND ug/L 07/19/18 10:32 92-87-5 L207/12/18 20:2750.0 5.1 1 Benzo(a)anthracene 5.3 ug/L 07/19/18 10:32 56-55-307/12/18 20:275.0 0.33 1 Benzo(a)pyrene 1.3J ug/L 07/19/18 10:32 50-32-807/12/18 20:275.0 0.30 1 Benzo(b)fluoranthene 1.5J ug/L 07/19/18 10:32 205-99-207/12/18 20:275.0 0.28 1 Benzo(g,h,i)perylene ND ug/L 07/19/18 10:32 191-24-207/12/18 20:275.0 0.38 1 Benzo(k)fluoranthene 1.7J ug/L 07/19/18 10:32 207-08-907/12/18 20:275.0 0.43 1 4-Bromophenylphenyl ether ND ug/L 07/19/18 10:32 101-55-307/12/18 20:275.0 0.82 1 Butylbenzylphthalate 6.1 ug/L 07/19/18 10:32 85-68-707/12/18 20:275.0 0.79 1 4-Chloro-3-methylphenol ND ug/L 07/19/18 10:32 59-50-707/12/18 20:275.0 3.7 1 bis(2-Chloroethoxy)methane ND ug/L 07/19/18 10:32 111-91-107/12/18 20:2710.0 0.92 1 bis(2-Chloroethyl) ether ND ug/L 07/19/18 10:32 111-44-407/12/18 20:275.0 1.0 1 2-Chloronaphthalene ND ug/L 07/19/18 10:32 91-58-707/12/18 20:275.0 0.98 1 2-Chlorophenol ND ug/L 07/19/18 10:32 95-57-807/12/18 20:275.0 1.3 1 4-Chlorophenylphenyl ether ND ug/L 07/19/18 10:32 7005-72-307/12/18 20:275.0 0.87 1 Chrysene 5.7 ug/L 07/19/18 10:32 218-01-907/12/18 20:275.0 0.21 1 Dibenz(a,h)anthracene ND ug/L 07/19/18 10:32 53-70-307/12/18 20:275.0 0.55 1 3,3'-Dichlorobenzidine ND ug/L 07/19/18 10:32 91-94-107/12/18 20:2725.0 2.1 1 2,4-Dichlorophenol ND ug/L 07/19/18 10:32 120-83-207/12/18 20:275.0 1.7 1 Diethylphthalate ND ug/L 07/19/18 10:32 84-66-207/12/18 20:275.0 0.58 1 2,4-Dimethylphenol ND ug/L 07/19/18 10:32 105-67-907/12/18 20:2710.0 1.2 1 Dimethylphthalate ND ug/L 07/19/18 10:32 131-11-307/12/18 20:275.0 0.76 1 Di-n-butylphthalate ND ug/L 07/19/18 10:32 84-74-207/12/18 20:275.0 0.75 1 4,6-Dinitro-2-methylphenol ND ug/L 07/19/18 10:32 534-52-107/12/18 20:2720.0 2.6 1 2,4-Dinitrophenol ND ug/L 07/19/18 10:32 51-28-507/12/18 20:2750.0 9.0 1 2,4-Dinitrotoluene ND ug/L 07/19/18 10:32 121-14-207/12/18 20:275.0 0.90 1 2,6-Dinitrotoluene ND ug/L 07/19/18 10:32 606-20-207/12/18 20:275.0 0.98 1 Di-n-octylphthalate 1.9J ug/L 07/19/18 10:32 117-84-007/12/18 20:275.0 0.66 1 1,2-Diphenylhydrazine ND ug/L 07/19/18 10:32 122-66-707/12/18 20:275.0 0.90 1 bis(2-Ethylhexyl)phthalate 4.8J ug/L 07/19/18 10:32 117-81-707/12/18 20:275.0 0.79 1 Fluoranthene ND ug/L 07/19/18 10:32 206-44-007/12/18 20:275.0 0.21 1 Fluorene ND ug/L 07/19/18 10:32 86-73-707/12/18 20:275.0 0.21 1 Hexachloro-1,3-butadiene ND ug/L 07/19/18 10:32 87-68-307/12/18 20:275.0 0.94 1 Hexachlorobenzene ND ug/L 07/19/18 10:32 118-74-107/12/18 20:275.0 0.72 1 Hexachlorocyclopentadiene ND ug/L 07/19/18 10:32 77-47-407/12/18 20:2710.0 0.88 1 Hexachloroethane ND ug/L 07/19/18 10:32 67-72-1 L207/12/18 20:275.0 1.1 1 Indeno(1,2,3-cd)pyrene ND ug/L 07/19/18 10:32 193-39-507/12/18 20:275.0 0.29 1 Isophorone ND ug/L 07/19/18 10:32 78-59-107/12/18 20:2710.0 0.89 1 2-Methylnaphthalene ND ug/L 07/19/18 10:32 91-57-607/12/18 20:275.0 0.28 1 3&4-Methylphenol(m&p Cresol)ND ug/L 07/19/18 10:32 15831-10-4 N207/12/18 20:2710.0 2.0 1 Naphthalene ND ug/L 07/19/18 10:32 91-20-307/12/18 20:275.0 0.34 1 Nitrobenzene ND ug/L 07/19/18 10:32 98-95-307/12/18 20:275.0 1.1 1 2-Nitrophenol ND ug/L 07/19/18 10:32 88-75-507/12/18 20:275.0 0.91 1 4-Nitrophenol 9.8J ug/L 07/19/18 10:32 100-02-707/12/18 20:2750.0 4.1 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 08/10/2018 07:37 AM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 6 of 61 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92391708 Little Mountain Creek SW PPL Sample:ABL-SW008-F005 Lab ID:92391708001 Collected:07/12/18 07:10 Received:07/12/18 12:30 Matrix:Water Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 625.1 Preparation Method: EPA 625.1625 MSSV N-Nitrosodimethylamine ND ug/L 07/19/18 10:32 62-75-907/12/18 20:275.0 0.91 1 N-Nitroso-di-n-propylamine ND ug/L 07/19/18 10:32 621-64-707/12/18 20:275.0 0.99 1 N-Nitrosodiphenylamine ND ug/L 07/19/18 10:32 86-30-607/12/18 20:2710.0 1.0 1 2,2'-Oxybis(1-chloropropane)ND ug/L 07/19/18 10:32 108-60-107/12/18 20:275.0 0.95 1 Pentachlorophenol ND ug/L 07/19/18 10:32 87-86-507/12/18 20:2710.0 4.6 1 Phenanthrene ND ug/L 07/19/18 10:32 85-01-807/12/18 20:275.0 0.22 1 Phenol ND ug/L 07/19/18 10:32 108-95-207/12/18 20:275.0 1.9 1 Pyrene 1.2J ug/L 07/19/18 10:32 129-00-007/12/18 20:275.0 0.19 1 2,4,6-Trichlorophenol ND ug/L 07/19/18 10:32 88-06-2 L207/12/18 20:2710.0 1.3 1 Surrogates Nitrobenzene-d5 (S)73 %07/19/18 10:32 4165-60-007/12/18 20:2710-120 1 2-Fluorobiphenyl (S)68 %07/19/18 10:32 321-60-807/12/18 20:2715-120 1 Terphenyl-d14 (S)73 %07/19/18 10:32 1718-51-007/12/18 20:2711-131 1 Phenol-d6 (S)23 %07/19/18 10:32 13127-88-307/12/18 20:2710-120 1 2-Fluorophenol (S)35 %07/19/18 10:32 367-12-407/12/18 20:2710-120 1 2,4,6-Tribromophenol (S)92 %07/19/18 10:32 118-79-607/12/18 20:2710-137 1 Analytical Method: EPA 624624 Volatile Organics Acrolein ND ug/L 07/13/18 23:50 107-02-85.0 1.0 1 Acrylonitrile ND ug/L 07/13/18 23:50 107-13-150.0 11.5 1 Benzene ND ug/L 07/13/18 23:50 71-43-22.0 1.7 1 Bromodichloromethane ND ug/L 07/13/18 23:50 75-27-42.0 1.7 1 Bromoform ND ug/L 07/13/18 23:50 75-25-22.0 1.5 1 Bromomethane ND ug/L 07/13/18 23:50 74-83-92.0 1.0 1 Carbon tetrachloride ND ug/L 07/13/18 23:50 56-23-52.0 1.9 1 Chlorobenzene ND ug/L 07/13/18 23:50 108-90-72.0 1.7 1 Chloroethane ND ug/L 07/13/18 23:50 75-00-32.0 1.6 1 2-Chloroethylvinyl ether ND ug/L 07/13/18 23:50 110-75-8 c25.0 2.2 1 Chloroform ND ug/L 07/13/18 23:50 67-66-32.0 1.9 1 Chloromethane ND ug/L 07/13/18 23:50 74-87-32.0 1.5 1 Dibromochloromethane ND ug/L 07/13/18 23:50 124-48-12.0 1.8 1 1,2-Dichlorobenzene ND ug/L 07/13/18 23:50 95-50-12.0 1.5 1 1,3-Dichlorobenzene ND ug/L 07/13/18 23:50 541-73-12.0 1.5 1 1,4-Dichlorobenzene ND ug/L 07/13/18 23:50 106-46-72.0 1.5 1 1,1-Dichloroethane ND ug/L 07/13/18 23:50 75-34-32.0 1.8 1 1,2-Dichloroethane ND ug/L 07/13/18 23:50 107-06-22.0 1.8 1 1,1-Dichloroethene ND ug/L 07/13/18 23:50 75-35-42.0 1.9 1 trans-1,2-Dichloroethene ND ug/L 07/13/18 23:50 156-60-52.0 1.8 1 1,2-Dichloropropane ND ug/L 07/13/18 23:50 78-87-52.0 1.7 1 cis-1,3-Dichloropropene ND ug/L 07/13/18 23:50 10061-01-52.0 1.6 1 trans-1,3-Dichloropropene ND ug/L 07/13/18 23:50 10061-02-62.0 1.6 1 Ethylbenzene ND ug/L 07/13/18 23:50 100-41-42.0 1.6 1 Methylene Chloride ND ug/L 07/13/18 23:50 75-09-22.0 1.9 1 1,1,2,2-Tetrachloroethane ND ug/L 07/13/18 23:50 79-34-52.0 1.5 1 Tetrachloroethene ND ug/L 07/13/18 23:50 127-18-42.0 1.8 1 Toluene ND ug/L 07/13/18 23:50 108-88-32.0 1.6 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 08/10/2018 07:37 AM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 7 of 61 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92391708 Little Mountain Creek SW PPL Sample:ABL-SW008-F005 Lab ID:92391708001 Collected:07/12/18 07:10 Received:07/12/18 12:30 Matrix:Water Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 624624 Volatile Organics 1,2,4-Trichlorobenzene ND ug/L 07/13/18 23:50 120-82-12.0 1.7 1 1,1,1-Trichloroethane ND ug/L 07/13/18 23:50 71-55-62.0 1.9 1 1,1,2-Trichloroethane ND ug/L 07/13/18 23:50 79-00-52.0 1.7 1 Trichloroethene ND ug/L 07/13/18 23:50 79-01-62.0 1.8 1 Trichlorofluoromethane ND ug/L 07/13/18 23:50 75-69-42.0 1.7 1 Vinyl chloride ND ug/L 07/13/18 23:50 75-01-42.0 1.5 1 Surrogates 4-Bromofluorobenzene (S)102 %07/13/18 23:50 460-00-470-130 1 Toluene-d8 (S)110 %07/13/18 23:50 2037-26-570-130 1 1,2-Dichloroethane-d4 (S)103 %07/13/18 23:50 17060-07-070-130 1 Analytical Method: EPA 420.4 Rev 1.0 1993420.4 Phenolics, Total Phenol 0.0090J mg/L 07/19/18 12:51 108-95-2 B,B00.010 0.0050 1 Analytical Method: SM 4500-CN-E-20114500CNE Cyanide, Total Cyanide ND mg/L 07/17/18 15:17 57-12-50.0080 0.0040 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 08/10/2018 07:37 AM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 8 of 61 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92391708 Little Mountain Creek SW PPL Sample:ABL-SW008-D005 Lab ID:92391708002 Collected:07/12/18 07:30 Received:07/12/18 12:30 Matrix:Water Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 608.3 Preparation Method: EPA 608.3608 PCB Pest RVE Aldrin ND ug/L 07/19/18 17:29 309-00-207/18/18 23:580.050 0.050 1 alpha-BHC ND ug/L 07/19/18 17:29 319-84-607/18/18 23:580.050 0.050 1 beta-BHC ND ug/L 07/19/18 17:29 319-85-707/18/18 23:580.050 0.050 1 delta-BHC ND ug/L 07/19/18 17:29 319-86-807/18/18 23:580.050 0.050 1 gamma-BHC (Lindane)ND ug/L 07/19/18 17:29 58-89-907/18/18 23:580.050 0.050 1 Chlordane (Technical)ND ug/L 07/19/18 17:29 57-74-907/18/18 23:580.50 0.50 1 4,4'-DDD ND ug/L 07/19/18 17:29 72-54-807/18/18 23:580.050 0.050 1 4,4'-DDE ND ug/L 07/19/18 17:29 72-55-907/18/18 23:580.050 0.050 1 4,4'-DDT ND ug/L 07/19/18 17:29 50-29-307/18/18 23:580.050 0.050 1 Dieldrin ND ug/L 07/19/18 17:29 60-57-107/18/18 23:580.050 0.050 1 Endosulfan I ND ug/L 07/19/18 17:29 959-98-807/18/18 23:580.050 0.050 1 Endosulfan II ND ug/L 07/19/18 17:29 33213-65-907/18/18 23:580.050 0.050 1 Endosulfan sulfate ND ug/L 07/19/18 17:29 1031-07-807/18/18 23:580.050 0.050 1 Endrin ND ug/L 07/19/18 17:29 72-20-807/18/18 23:580.050 0.050 1 Endrin aldehyde ND ug/L 07/19/18 17:29 7421-93-407/18/18 23:580.050 0.050 1 Heptachlor ND ug/L 07/19/18 17:29 76-44-807/18/18 23:580.050 0.050 1 Heptachlor epoxide ND ug/L 07/19/18 17:29 1024-57-307/18/18 23:580.050 0.050 1 PCB-1016 (Aroclor 1016)ND ug/L 07/19/18 17:29 12674-11-207/18/18 23:580.50 0.50 1 PCB-1221 (Aroclor 1221)ND ug/L 07/19/18 17:29 11104-28-207/18/18 23:580.50 0.50 1 PCB-1232 (Aroclor 1232)ND ug/L 07/19/18 17:29 11141-16-507/18/18 23:580.50 0.50 1 PCB-1242 (Aroclor 1242)ND ug/L 07/19/18 17:29 53469-21-907/18/18 23:580.50 0.50 1 PCB-1248 (Aroclor 1248)ND ug/L 07/19/18 17:29 12672-29-607/18/18 23:580.50 0.50 1 PCB-1254 (Aroclor 1254)ND ug/L 07/19/18 17:29 11097-69-107/18/18 23:580.50 0.50 1 PCB-1260 (Aroclor 1260)ND ug/L 07/19/18 17:29 11096-82-507/18/18 23:580.50 0.50 1 Toxaphene ND ug/L 07/19/18 17:29 8001-35-207/18/18 23:580.50 0.50 1 Surrogates Tetrachloro-m-xylene (S)39 %07/19/18 17:29 877-09-8 S207/18/18 23:5860-140 1 Decachlorobiphenyl (S)38 %07/19/18 17:29 2051-24-3 S207/18/18 23:5860-140 1 Analytical Method: EPA 200.7 Rev 4.4 1994 Preparation Method: EPA 200.7 Rev 4.4 1994200.7 MET ICP Antimony ND ug/L 07/14/18 03:37 7440-36-007/13/18 05:205.0 3.9 1 Arsenic ND ug/L 07/14/18 03:37 7440-38-207/13/18 05:2010.0 5.0 1 Beryllium ND ug/L 07/14/18 03:37 7440-41-707/13/18 05:201.0 0.050 1 Cadmium ND ug/L 07/14/18 03:37 7440-43-907/13/18 05:201.0 0.50 1 Chromium ND ug/L 07/14/18 03:37 7440-47-307/13/18 05:205.0 2.5 1 Copper ND ug/L 07/14/18 03:37 7440-50-807/13/18 05:205.0 2.5 1 Lead ND ug/L 07/14/18 03:37 7439-92-107/13/18 05:205.0 2.5 1 Nickel ND ug/L 07/14/18 03:37 7440-02-007/13/18 05:205.0 2.5 1 Selenium ND ug/L 07/14/18 03:37 7782-49-207/13/18 05:2010.0 5.0 1 Silver ND ug/L 07/14/18 03:37 7440-22-407/13/18 05:205.0 2.5 1 Thallium ND ug/L 07/14/18 03:37 7440-28-007/13/18 05:2010.0 5.0 1 Zinc ND ug/L 07/14/18 03:37 7440-66-607/13/18 05:2010.0 2.5 1 Analytical Method: EPA 245.1 Rev 3.0 1994 Preparation Method: EPA 245.1 Rev 3.0 1994245.1 Mercury Mercury ND ug/L 07/16/18 09:45 7439-97-607/13/18 14:500.20 0.070 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 08/10/2018 07:37 AM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 9 of 61 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92391708 Little Mountain Creek SW PPL Sample:ABL-SW008-D005 Lab ID:92391708002 Collected:07/12/18 07:30 Received:07/12/18 12:30 Matrix:Water Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 625.1 Preparation Method: EPA 625.1625 MSSV Acenaphthene ND ug/L 07/19/18 11:02 83-32-907/12/18 20:275.0 0.25 1 Acenaphthylene ND ug/L 07/19/18 11:02 208-96-807/12/18 20:275.0 0.21 1 Anthracene ND ug/L 07/19/18 11:02 120-12-707/12/18 20:275.0 0.14 1 Benzidine ND ug/L 07/19/18 11:02 92-87-5 L207/12/18 20:2750.0 5.1 1 Benzo(a)anthracene 2.7J ug/L 07/19/18 11:02 56-55-307/12/18 20:275.0 0.33 1 Benzo(a)pyrene 1.1J ug/L 07/19/18 11:02 50-32-807/12/18 20:275.0 0.30 1 Benzo(b)fluoranthene 1.1J ug/L 07/19/18 11:02 205-99-207/12/18 20:275.0 0.28 1 Benzo(g,h,i)perylene ND ug/L 07/19/18 11:02 191-24-207/12/18 20:275.0 0.38 1 Benzo(k)fluoranthene 1.1J ug/L 07/19/18 11:02 207-08-907/12/18 20:275.0 0.43 1 4-Bromophenylphenyl ether ND ug/L 07/19/18 11:02 101-55-307/12/18 20:275.0 0.82 1 Butylbenzylphthalate 2.2J ug/L 07/19/18 11:02 85-68-707/12/18 20:275.0 0.79 1 4-Chloro-3-methylphenol ND ug/L 07/19/18 11:02 59-50-707/12/18 20:275.0 3.7 1 bis(2-Chloroethoxy)methane ND ug/L 07/19/18 11:02 111-91-107/12/18 20:2710.0 0.92 1 bis(2-Chloroethyl) ether ND ug/L 07/19/18 11:02 111-44-407/12/18 20:275.0 1.0 1 2-Chloronaphthalene ND ug/L 07/19/18 11:02 91-58-707/12/18 20:275.0 0.98 1 2-Chlorophenol ND ug/L 07/19/18 11:02 95-57-807/12/18 20:275.0 1.3 1 4-Chlorophenylphenyl ether ND ug/L 07/19/18 11:02 7005-72-307/12/18 20:275.0 0.87 1 Chrysene 3.0J ug/L 07/19/18 11:02 218-01-907/12/18 20:275.0 0.21 1 Dibenz(a,h)anthracene ND ug/L 07/19/18 11:02 53-70-307/12/18 20:275.0 0.55 1 3,3'-Dichlorobenzidine ND ug/L 07/19/18 11:02 91-94-107/12/18 20:2725.0 2.1 1 2,4-Dichlorophenol ND ug/L 07/19/18 11:02 120-83-207/12/18 20:275.0 1.7 1 Diethylphthalate ND ug/L 07/19/18 11:02 84-66-207/12/18 20:275.0 0.58 1 2,4-Dimethylphenol ND ug/L 07/19/18 11:02 105-67-907/12/18 20:2710.0 1.2 1 Dimethylphthalate ND ug/L 07/19/18 11:02 131-11-307/12/18 20:275.0 0.76 1 Di-n-butylphthalate ND ug/L 07/19/18 11:02 84-74-207/12/18 20:275.0 0.75 1 4,6-Dinitro-2-methylphenol ND ug/L 07/19/18 11:02 534-52-107/12/18 20:2720.0 2.6 1 2,4-Dinitrophenol ND ug/L 07/19/18 11:02 51-28-507/12/18 20:2750.0 9.0 1 2,4-Dinitrotoluene ND ug/L 07/19/18 11:02 121-14-207/12/18 20:275.0 0.90 1 2,6-Dinitrotoluene ND ug/L 07/19/18 11:02 606-20-207/12/18 20:275.0 0.98 1 Di-n-octylphthalate 1.2J ug/L 07/19/18 11:02 117-84-007/12/18 20:275.0 0.66 1 1,2-Diphenylhydrazine ND ug/L 07/19/18 11:02 122-66-707/12/18 20:275.0 0.90 1 bis(2-Ethylhexyl)phthalate 2.6J ug/L 07/19/18 11:02 117-81-707/12/18 20:275.0 0.79 1 Fluoranthene ND ug/L 07/19/18 11:02 206-44-007/12/18 20:275.0 0.21 1 Fluorene ND ug/L 07/19/18 11:02 86-73-707/12/18 20:275.0 0.21 1 Hexachloro-1,3-butadiene ND ug/L 07/19/18 11:02 87-68-307/12/18 20:275.0 0.94 1 Hexachlorobenzene ND ug/L 07/19/18 11:02 118-74-107/12/18 20:275.0 0.72 1 Hexachlorocyclopentadiene ND ug/L 07/19/18 11:02 77-47-407/12/18 20:2710.0 0.88 1 Hexachloroethane ND ug/L 07/19/18 11:02 67-72-1 L207/12/18 20:275.0 1.1 1 Indeno(1,2,3-cd)pyrene ND ug/L 07/19/18 11:02 193-39-507/12/18 20:275.0 0.29 1 Isophorone ND ug/L 07/19/18 11:02 78-59-107/12/18 20:2710.0 0.89 1 2-Methylnaphthalene ND ug/L 07/19/18 11:02 91-57-607/12/18 20:275.0 0.28 1 3&4-Methylphenol(m&p Cresol)ND ug/L 07/19/18 11:02 15831-10-4 N207/12/18 20:2710.0 2.0 1 Naphthalene ND ug/L 07/19/18 11:02 91-20-307/12/18 20:275.0 0.34 1 Nitrobenzene ND ug/L 07/19/18 11:02 98-95-307/12/18 20:275.0 1.1 1 2-Nitrophenol ND ug/L 07/19/18 11:02 88-75-507/12/18 20:275.0 0.91 1 4-Nitrophenol ND ug/L 07/19/18 11:02 100-02-707/12/18 20:2750.0 4.1 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 08/10/2018 07:37 AM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 10 of 61 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92391708 Little Mountain Creek SW PPL Sample:ABL-SW008-D005 Lab ID:92391708002 Collected:07/12/18 07:30 Received:07/12/18 12:30 Matrix:Water Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 625.1 Preparation Method: EPA 625.1625 MSSV N-Nitrosodimethylamine ND ug/L 07/19/18 11:02 62-75-907/12/18 20:275.0 0.91 1 N-Nitroso-di-n-propylamine ND ug/L 07/19/18 11:02 621-64-707/12/18 20:275.0 0.99 1 N-Nitrosodiphenylamine ND ug/L 07/19/18 11:02 86-30-607/12/18 20:2710.0 1.0 1 2,2'-Oxybis(1-chloropropane)ND ug/L 07/19/18 11:02 108-60-107/12/18 20:275.0 0.95 1 Pentachlorophenol ND ug/L 07/19/18 11:02 87-86-507/12/18 20:2710.0 4.6 1 Phenanthrene ND ug/L 07/19/18 11:02 85-01-807/12/18 20:275.0 0.22 1 Phenol ND ug/L 07/19/18 11:02 108-95-207/12/18 20:275.0 1.9 1 Pyrene ND ug/L 07/19/18 11:02 129-00-007/12/18 20:275.0 0.19 1 2,4,6-Trichlorophenol ND ug/L 07/19/18 11:02 88-06-2 L207/12/18 20:2710.0 1.3 1 Surrogates Nitrobenzene-d5 (S)66 %07/19/18 11:02 4165-60-007/12/18 20:2710-120 1 2-Fluorobiphenyl (S)63 %07/19/18 11:02 321-60-807/12/18 20:2715-120 1 Terphenyl-d14 (S)74 %07/19/18 11:02 1718-51-007/12/18 20:2711-131 1 Phenol-d6 (S)25 %07/19/18 11:02 13127-88-307/12/18 20:2710-120 1 2-Fluorophenol (S)33 %07/19/18 11:02 367-12-407/12/18 20:2710-120 1 2,4,6-Tribromophenol (S)83 %07/19/18 11:02 118-79-607/12/18 20:2710-137 1 Analytical Method: EPA 624624 Volatile Organics Acrolein ND ug/L 07/14/18 00:07 107-02-85.0 1.0 1 Acrylonitrile ND ug/L 07/14/18 00:07 107-13-150.0 11.5 1 Benzene ND ug/L 07/14/18 00:07 71-43-22.0 1.7 1 Bromodichloromethane ND ug/L 07/14/18 00:07 75-27-42.0 1.7 1 Bromoform ND ug/L 07/14/18 00:07 75-25-22.0 1.5 1 Bromomethane ND ug/L 07/14/18 00:07 74-83-92.0 1.0 1 Carbon tetrachloride ND ug/L 07/14/18 00:07 56-23-52.0 1.9 1 Chlorobenzene ND ug/L 07/14/18 00:07 108-90-72.0 1.7 1 Chloroethane ND ug/L 07/14/18 00:07 75-00-32.0 1.6 1 2-Chloroethylvinyl ether ND ug/L 07/14/18 00:07 110-75-8 c25.0 2.2 1 Chloroform ND ug/L 07/14/18 00:07 67-66-32.0 1.9 1 Chloromethane ND ug/L 07/14/18 00:07 74-87-32.0 1.5 1 Dibromochloromethane ND ug/L 07/14/18 00:07 124-48-12.0 1.8 1 1,2-Dichlorobenzene ND ug/L 07/14/18 00:07 95-50-12.0 1.5 1 1,3-Dichlorobenzene ND ug/L 07/14/18 00:07 541-73-12.0 1.5 1 1,4-Dichlorobenzene ND ug/L 07/14/18 00:07 106-46-72.0 1.5 1 1,1-Dichloroethane ND ug/L 07/14/18 00:07 75-34-32.0 1.8 1 1,2-Dichloroethane ND ug/L 07/14/18 00:07 107-06-22.0 1.8 1 1,1-Dichloroethene ND ug/L 07/14/18 00:07 75-35-42.0 1.9 1 trans-1,2-Dichloroethene ND ug/L 07/14/18 00:07 156-60-52.0 1.8 1 1,2-Dichloropropane ND ug/L 07/14/18 00:07 78-87-52.0 1.7 1 cis-1,3-Dichloropropene ND ug/L 07/14/18 00:07 10061-01-52.0 1.6 1 trans-1,3-Dichloropropene ND ug/L 07/14/18 00:07 10061-02-62.0 1.6 1 Ethylbenzene ND ug/L 07/14/18 00:07 100-41-42.0 1.6 1 Methylene Chloride ND ug/L 07/14/18 00:07 75-09-22.0 1.9 1 1,1,2,2-Tetrachloroethane ND ug/L 07/14/18 00:07 79-34-52.0 1.5 1 Tetrachloroethene ND ug/L 07/14/18 00:07 127-18-42.0 1.8 1 Toluene ND ug/L 07/14/18 00:07 108-88-32.0 1.6 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 08/10/2018 07:37 AM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 11 of 61 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92391708 Little Mountain Creek SW PPL Sample:ABL-SW008-D005 Lab ID:92391708002 Collected:07/12/18 07:30 Received:07/12/18 12:30 Matrix:Water Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 624624 Volatile Organics 1,2,4-Trichlorobenzene ND ug/L 07/14/18 00:07 120-82-12.0 1.7 1 1,1,1-Trichloroethane ND ug/L 07/14/18 00:07 71-55-62.0 1.9 1 1,1,2-Trichloroethane ND ug/L 07/14/18 00:07 79-00-52.0 1.7 1 Trichloroethene ND ug/L 07/14/18 00:07 79-01-62.0 1.8 1 Trichlorofluoromethane ND ug/L 07/14/18 00:07 75-69-42.0 1.7 1 Vinyl chloride ND ug/L 07/14/18 00:07 75-01-42.0 1.5 1 Surrogates 4-Bromofluorobenzene (S)105 %07/14/18 00:07 460-00-470-130 1 Toluene-d8 (S)110 %07/14/18 00:07 2037-26-570-130 1 1,2-Dichloroethane-d4 (S)105 %07/14/18 00:07 17060-07-070-130 1 Analytical Method: EPA 420.4 Rev 1.0 1993420.4 Phenolics, Total Phenol 0.0066J mg/L 07/19/18 12:52 108-95-2 B,B00.010 0.0050 1 Analytical Method: SM 4500-CN-E-20114500CNE Cyanide, Total Cyanide ND mg/L 07/17/18 15:17 57-12-50.0080 0.0040 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 08/10/2018 07:37 AM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 12 of 61 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92391708 Little Mountain Creek SW PPL Sample:ABL-SW012-F005 Lab ID:92391708003 Collected:07/12/18 09:55 Received:07/12/18 12:30 Matrix:Water Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 608.3 Preparation Method: EPA 608.3608 PCB Pest RVE Aldrin ND ug/L 07/19/18 17:41 309-00-207/18/18 23:580.050 0.050 1 alpha-BHC ND ug/L 07/19/18 17:41 319-84-607/18/18 23:580.050 0.050 1 beta-BHC ND ug/L 07/19/18 17:41 319-85-707/18/18 23:580.050 0.050 1 delta-BHC ND ug/L 07/19/18 17:41 319-86-807/18/18 23:580.050 0.050 1 gamma-BHC (Lindane)ND ug/L 07/19/18 17:41 58-89-907/18/18 23:580.050 0.050 1 Chlordane (Technical)ND ug/L 07/19/18 17:41 57-74-907/18/18 23:580.50 0.50 1 4,4'-DDD ND ug/L 07/19/18 17:41 72-54-807/18/18 23:580.050 0.050 1 4,4'-DDE ND ug/L 07/19/18 17:41 72-55-907/18/18 23:580.050 0.050 1 4,4'-DDT ND ug/L 07/19/18 17:41 50-29-307/18/18 23:580.050 0.050 1 Dieldrin ND ug/L 07/19/18 17:41 60-57-107/18/18 23:580.050 0.050 1 Endosulfan I ND ug/L 07/19/18 17:41 959-98-807/18/18 23:580.050 0.050 1 Endosulfan II ND ug/L 07/19/18 17:41 33213-65-907/18/18 23:580.050 0.050 1 Endosulfan sulfate ND ug/L 07/19/18 17:41 1031-07-807/18/18 23:580.050 0.050 1 Endrin ND ug/L 07/19/18 17:41 72-20-807/18/18 23:580.050 0.050 1 Endrin aldehyde ND ug/L 07/19/18 17:41 7421-93-407/18/18 23:580.050 0.050 1 Heptachlor ND ug/L 07/19/18 17:41 76-44-807/18/18 23:580.050 0.050 1 Heptachlor epoxide ND ug/L 07/19/18 17:41 1024-57-307/18/18 23:580.050 0.050 1 PCB-1016 (Aroclor 1016)ND ug/L 07/19/18 17:41 12674-11-207/18/18 23:580.50 0.50 1 PCB-1221 (Aroclor 1221)ND ug/L 07/19/18 17:41 11104-28-207/18/18 23:580.50 0.50 1 PCB-1232 (Aroclor 1232)ND ug/L 07/19/18 17:41 11141-16-507/18/18 23:580.50 0.50 1 PCB-1242 (Aroclor 1242)ND ug/L 07/19/18 17:41 53469-21-907/18/18 23:580.50 0.50 1 PCB-1248 (Aroclor 1248)ND ug/L 07/19/18 17:41 12672-29-607/18/18 23:580.50 0.50 1 PCB-1254 (Aroclor 1254)ND ug/L 07/19/18 17:41 11097-69-107/18/18 23:580.50 0.50 1 PCB-1260 (Aroclor 1260)ND ug/L 07/19/18 17:41 11096-82-507/18/18 23:580.50 0.50 1 Toxaphene ND ug/L 07/19/18 17:41 8001-35-207/18/18 23:580.50 0.50 1 Surrogates Tetrachloro-m-xylene (S)66 %07/19/18 17:41 877-09-807/18/18 23:5860-140 1 Decachlorobiphenyl (S)61 %07/19/18 17:41 2051-24-307/18/18 23:5860-140 1 Analytical Method: EPA 200.7 Rev 4.4 1994 Preparation Method: EPA 200.7 Rev 4.4 1994200.7 MET ICP Antimony ND ug/L 07/14/18 03:40 7440-36-007/13/18 05:205.0 3.9 1 Arsenic ND ug/L 07/14/18 03:40 7440-38-207/13/18 05:2010.0 5.0 1 Beryllium ND ug/L 07/14/18 03:40 7440-41-707/13/18 05:201.0 0.050 1 Cadmium ND ug/L 07/14/18 03:40 7440-43-907/13/18 05:201.0 0.50 1 Chromium ND ug/L 07/14/18 03:40 7440-47-307/13/18 05:205.0 2.5 1 Copper ND ug/L 07/14/18 03:40 7440-50-807/13/18 05:205.0 2.5 1 Lead ND ug/L 07/14/18 03:40 7439-92-107/13/18 05:205.0 2.5 1 Nickel ND ug/L 07/14/18 03:40 7440-02-007/13/18 05:205.0 2.5 1 Selenium ND ug/L 07/14/18 03:40 7782-49-207/13/18 05:2010.0 5.0 1 Silver ND ug/L 07/14/18 03:40 7440-22-407/13/18 05:205.0 2.5 1 Thallium ND ug/L 07/14/18 03:40 7440-28-007/13/18 05:2010.0 5.0 1 Zinc ND ug/L 07/14/18 03:40 7440-66-607/13/18 05:2010.0 2.5 1 Analytical Method: EPA 245.1 Rev 3.0 1994 Preparation Method: EPA 245.1 Rev 3.0 1994245.1 Mercury Mercury ND ug/L 07/16/18 09:48 7439-97-607/13/18 14:500.20 0.070 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 08/10/2018 07:37 AM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 13 of 61 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92391708 Little Mountain Creek SW PPL Sample:ABL-SW012-F005 Lab ID:92391708003 Collected:07/12/18 09:55 Received:07/12/18 12:30 Matrix:Water Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 625.1 Preparation Method: EPA 625.1625 MSSV Acenaphthene ND ug/L 07/19/18 12:58 83-32-907/14/18 02:264.8 0.24 1 Acenaphthylene ND ug/L 07/19/18 12:58 208-96-807/14/18 02:264.8 0.20 1 Anthracene ND ug/L 07/19/18 12:58 120-12-707/14/18 02:264.8 0.13 1 Benzidine ND ug/L 07/19/18 12:58 92-87-5 L207/14/18 02:2648.1 4.9 1 Benzo(a)anthracene ND ug/L 07/19/18 12:58 56-55-307/14/18 02:264.8 0.32 1 Benzo(a)pyrene ND ug/L 07/19/18 12:58 50-32-807/14/18 02:264.8 0.29 1 Benzo(b)fluoranthene ND ug/L 07/19/18 12:58 205-99-207/14/18 02:264.8 0.27 1 Benzo(g,h,i)perylene ND ug/L 07/19/18 12:58 191-24-207/14/18 02:264.8 0.37 1 Benzo(k)fluoranthene ND ug/L 07/19/18 12:58 207-08-907/14/18 02:264.8 0.41 1 4-Bromophenylphenyl ether ND ug/L 07/19/18 12:58 101-55-307/14/18 02:264.8 0.79 1 Butylbenzylphthalate ND ug/L 07/19/18 12:58 85-68-707/14/18 02:264.8 0.76 1 4-Chloro-3-methylphenol ND ug/L 07/19/18 12:58 59-50-707/14/18 02:264.8 3.6 1 bis(2-Chloroethoxy)methane ND ug/L 07/19/18 12:58 111-91-107/14/18 02:269.6 0.88 1 bis(2-Chloroethyl) ether ND ug/L 07/19/18 12:58 111-44-407/14/18 02:264.8 0.96 1 2-Chloronaphthalene ND ug/L 07/19/18 12:58 91-58-707/14/18 02:264.8 0.94 1 2-Chlorophenol ND ug/L 07/19/18 12:58 95-57-807/14/18 02:264.8 1.2 1 4-Chlorophenylphenyl ether ND ug/L 07/19/18 12:58 7005-72-307/14/18 02:264.8 0.84 1 Chrysene ND ug/L 07/19/18 12:58 218-01-907/14/18 02:264.8 0.20 1 Dibenz(a,h)anthracene ND ug/L 07/19/18 12:58 53-70-307/14/18 02:264.8 0.53 1 3,3'-Dichlorobenzidine ND ug/L 07/19/18 12:58 91-94-107/14/18 02:2624.0 2.0 1 2,4-Dichlorophenol ND ug/L 07/19/18 12:58 120-83-207/14/18 02:264.8 1.6 1 Diethylphthalate ND ug/L 07/19/18 12:58 84-66-207/14/18 02:264.8 0.56 1 2,4-Dimethylphenol ND ug/L 07/19/18 12:58 105-67-907/14/18 02:269.6 1.2 1 Dimethylphthalate ND ug/L 07/19/18 12:58 131-11-307/14/18 02:264.8 0.73 1 Di-n-butylphthalate ND ug/L 07/19/18 12:58 84-74-207/14/18 02:264.8 0.72 1 4,6-Dinitro-2-methylphenol ND ug/L 07/19/18 12:58 534-52-107/14/18 02:2619.2 2.5 1 2,4-Dinitrophenol ND ug/L 07/19/18 12:58 51-28-507/14/18 02:2648.1 8.7 1 2,4-Dinitrotoluene ND ug/L 07/19/18 12:58 121-14-207/14/18 02:264.8 0.87 1 2,6-Dinitrotoluene ND ug/L 07/19/18 12:58 606-20-207/14/18 02:264.8 0.94 1 Di-n-octylphthalate ND ug/L 07/19/18 12:58 117-84-007/14/18 02:264.8 0.63 1 1,2-Diphenylhydrazine ND ug/L 07/19/18 12:58 122-66-707/14/18 02:264.8 0.87 1 bis(2-Ethylhexyl)phthalate ND ug/L 07/19/18 12:58 117-81-707/14/18 02:264.8 0.76 1 Fluoranthene ND ug/L 07/19/18 12:58 206-44-007/14/18 02:264.8 0.20 1 Fluorene ND ug/L 07/19/18 12:58 86-73-707/14/18 02:264.8 0.20 1 Hexachloro-1,3-butadiene ND ug/L 07/19/18 12:58 87-68-307/14/18 02:264.8 0.90 1 Hexachlorobenzene ND ug/L 07/19/18 12:58 118-74-107/14/18 02:264.8 0.69 1 Hexachlorocyclopentadiene ND ug/L 07/19/18 12:58 77-47-407/14/18 02:269.6 0.85 1 Hexachloroethane ND ug/L 07/19/18 12:58 67-72-107/14/18 02:264.8 1.1 1 Indeno(1,2,3-cd)pyrene ND ug/L 07/19/18 12:58 193-39-507/14/18 02:264.8 0.28 1 Isophorone ND ug/L 07/19/18 12:58 78-59-107/14/18 02:269.6 0.86 1 2-Methylnaphthalene ND ug/L 07/19/18 12:58 91-57-607/14/18 02:264.8 0.27 1 3&4-Methylphenol(m&p Cresol)ND ug/L 07/19/18 12:58 15831-10-4 N207/14/18 02:269.6 1.9 1 Naphthalene 1.1J ug/L 07/19/18 12:58 91-20-307/14/18 02:264.8 0.33 1 Nitrobenzene ND ug/L 07/19/18 12:58 98-95-307/14/18 02:264.8 1.1 1 2-Nitrophenol ND ug/L 07/19/18 12:58 88-75-507/14/18 02:264.8 0.88 1 4-Nitrophenol ND ug/L 07/19/18 12:58 100-02-707/14/18 02:2648.1 3.9 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 08/10/2018 07:37 AM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 14 of 61 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92391708 Little Mountain Creek SW PPL Sample:ABL-SW012-F005 Lab ID:92391708003 Collected:07/12/18 09:55 Received:07/12/18 12:30 Matrix:Water Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 625.1 Preparation Method: EPA 625.1625 MSSV N-Nitrosodimethylamine ND ug/L 07/19/18 12:58 62-75-907/14/18 02:264.8 0.88 1 N-Nitroso-di-n-propylamine ND ug/L 07/19/18 12:58 621-64-707/14/18 02:264.8 0.95 1 N-Nitrosodiphenylamine ND ug/L 07/19/18 12:58 86-30-607/14/18 02:269.6 0.96 1 2,2'-Oxybis(1-chloropropane)ND ug/L 07/19/18 12:58 108-60-107/14/18 02:264.8 0.91 1 Pentachlorophenol ND ug/L 07/19/18 12:58 87-86-507/14/18 02:269.6 4.4 1 Phenanthrene ND ug/L 07/19/18 12:58 85-01-807/14/18 02:264.8 0.21 1 Phenol ND ug/L 07/19/18 12:58 108-95-207/14/18 02:264.8 1.8 1 Pyrene ND ug/L 07/19/18 12:58 129-00-007/14/18 02:264.8 0.18 1 2,4,6-Trichlorophenol ND ug/L 07/19/18 12:58 88-06-207/14/18 02:269.6 1.2 1 Surrogates Nitrobenzene-d5 (S)70 %07/19/18 12:58 4165-60-007/14/18 02:2610-120 1 2-Fluorobiphenyl (S)64 %07/19/18 12:58 321-60-807/14/18 02:2615-120 1 Terphenyl-d14 (S)61 %07/19/18 12:58 1718-51-007/14/18 02:2611-131 1 Phenol-d6 (S)24 %07/19/18 12:58 13127-88-307/14/18 02:2610-120 1 2-Fluorophenol (S)37 %07/19/18 12:58 367-12-407/14/18 02:2610-120 1 2,4,6-Tribromophenol (S)87 %07/19/18 12:58 118-79-607/14/18 02:2610-137 1 Analytical Method: EPA 624624 Volatile Organics Acrolein ND ug/L 07/14/18 00:24 107-02-85.0 1.0 1 Acrylonitrile ND ug/L 07/14/18 00:24 107-13-150.0 11.5 1 Benzene ND ug/L 07/14/18 00:24 71-43-22.0 1.7 1 Bromodichloromethane ND ug/L 07/14/18 00:24 75-27-42.0 1.7 1 Bromoform ND ug/L 07/14/18 00:24 75-25-22.0 1.5 1 Bromomethane ND ug/L 07/14/18 00:24 74-83-92.0 1.0 1 Carbon tetrachloride ND ug/L 07/14/18 00:24 56-23-52.0 1.9 1 Chlorobenzene ND ug/L 07/14/18 00:24 108-90-72.0 1.7 1 Chloroethane ND ug/L 07/14/18 00:24 75-00-32.0 1.6 1 2-Chloroethylvinyl ether ND ug/L 07/14/18 00:24 110-75-8 c25.0 2.2 1 Chloroform ND ug/L 07/14/18 00:24 67-66-32.0 1.9 1 Chloromethane ND ug/L 07/14/18 00:24 74-87-32.0 1.5 1 Dibromochloromethane ND ug/L 07/14/18 00:24 124-48-12.0 1.8 1 1,2-Dichlorobenzene ND ug/L 07/14/18 00:24 95-50-12.0 1.5 1 1,3-Dichlorobenzene ND ug/L 07/14/18 00:24 541-73-12.0 1.5 1 1,4-Dichlorobenzene ND ug/L 07/14/18 00:24 106-46-72.0 1.5 1 1,1-Dichloroethane ND ug/L 07/14/18 00:24 75-34-32.0 1.8 1 1,2-Dichloroethane ND ug/L 07/14/18 00:24 107-06-22.0 1.8 1 1,1-Dichloroethene ND ug/L 07/14/18 00:24 75-35-42.0 1.9 1 trans-1,2-Dichloroethene ND ug/L 07/14/18 00:24 156-60-52.0 1.8 1 1,2-Dichloropropane ND ug/L 07/14/18 00:24 78-87-52.0 1.7 1 cis-1,3-Dichloropropene ND ug/L 07/14/18 00:24 10061-01-52.0 1.6 1 trans-1,3-Dichloropropene ND ug/L 07/14/18 00:24 10061-02-62.0 1.6 1 Ethylbenzene ND ug/L 07/14/18 00:24 100-41-42.0 1.6 1 Methylene Chloride ND ug/L 07/14/18 00:24 75-09-22.0 1.9 1 1,1,2,2-Tetrachloroethane ND ug/L 07/14/18 00:24 79-34-52.0 1.5 1 Tetrachloroethene ND ug/L 07/14/18 00:24 127-18-42.0 1.8 1 Toluene ND ug/L 07/14/18 00:24 108-88-32.0 1.6 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 08/10/2018 07:37 AM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 15 of 61 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92391708 Little Mountain Creek SW PPL Sample:ABL-SW012-F005 Lab ID:92391708003 Collected:07/12/18 09:55 Received:07/12/18 12:30 Matrix:Water Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 624624 Volatile Organics 1,2,4-Trichlorobenzene ND ug/L 07/14/18 00:24 120-82-12.0 1.7 1 1,1,1-Trichloroethane ND ug/L 07/14/18 00:24 71-55-62.0 1.9 1 1,1,2-Trichloroethane ND ug/L 07/14/18 00:24 79-00-52.0 1.7 1 Trichloroethene ND ug/L 07/14/18 00:24 79-01-62.0 1.8 1 Trichlorofluoromethane ND ug/L 07/14/18 00:24 75-69-42.0 1.7 1 Vinyl chloride ND ug/L 07/14/18 00:24 75-01-42.0 1.5 1 Surrogates 4-Bromofluorobenzene (S)104 %07/14/18 00:24 460-00-470-130 1 Toluene-d8 (S)113 %07/14/18 00:24 2037-26-570-130 1 1,2-Dichloroethane-d4 (S)102 %07/14/18 00:24 17060-07-070-130 1 Analytical Method: EPA 420.4 Rev 1.0 1993420.4 Phenolics, Total Phenol 0.0064J mg/L 07/19/18 12:52 108-95-2 B,B00.010 0.0050 1 Analytical Method: SM 4500-CN-E-20114500CNE Cyanide, Total Cyanide ND mg/L 07/25/18 05:58 57-12-50.0080 0.0040 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 08/10/2018 07:37 AM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 16 of 61 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92391708 Little Mountain Creek SW PPL Sample:ABL-TB001-F005 Lab ID:92391708004 Collected:07/12/18 00:00 Received:07/12/18 12:30 Matrix:Water Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 624624 Volatile Organics Acrolein ND ug/L 07/13/18 21:19 107-02-85.0 1.0 1 Acrylonitrile ND ug/L 07/13/18 21:19 107-13-150.0 11.5 1 Benzene ND ug/L 07/13/18 21:19 71-43-22.0 1.7 1 Bromodichloromethane ND ug/L 07/13/18 21:19 75-27-42.0 1.7 1 Bromoform ND ug/L 07/13/18 21:19 75-25-22.0 1.5 1 Bromomethane ND ug/L 07/13/18 21:19 74-83-92.0 1.0 1 Carbon tetrachloride ND ug/L 07/13/18 21:19 56-23-52.0 1.9 1 Chlorobenzene ND ug/L 07/13/18 21:19 108-90-72.0 1.7 1 Chloroethane ND ug/L 07/13/18 21:19 75-00-32.0 1.6 1 2-Chloroethylvinyl ether ND ug/L 07/13/18 21:19 110-75-8 c25.0 2.2 1 Chloroform ND ug/L 07/13/18 21:19 67-66-32.0 1.9 1 Chloromethane ND ug/L 07/13/18 21:19 74-87-32.0 1.5 1 Dibromochloromethane ND ug/L 07/13/18 21:19 124-48-12.0 1.8 1 1,2-Dichlorobenzene ND ug/L 07/13/18 21:19 95-50-12.0 1.5 1 1,3-Dichlorobenzene ND ug/L 07/13/18 21:19 541-73-12.0 1.5 1 1,4-Dichlorobenzene ND ug/L 07/13/18 21:19 106-46-72.0 1.5 1 1,1-Dichloroethane ND ug/L 07/13/18 21:19 75-34-32.0 1.8 1 1,2-Dichloroethane ND ug/L 07/13/18 21:19 107-06-22.0 1.8 1 1,1-Dichloroethene ND ug/L 07/13/18 21:19 75-35-42.0 1.9 1 trans-1,2-Dichloroethene ND ug/L 07/13/18 21:19 156-60-52.0 1.8 1 1,2-Dichloropropane ND ug/L 07/13/18 21:19 78-87-52.0 1.7 1 cis-1,3-Dichloropropene ND ug/L 07/13/18 21:19 10061-01-52.0 1.6 1 trans-1,3-Dichloropropene ND ug/L 07/13/18 21:19 10061-02-62.0 1.6 1 Ethylbenzene ND ug/L 07/13/18 21:19 100-41-42.0 1.6 1 Methylene Chloride ND ug/L 07/13/18 21:19 75-09-22.0 1.9 1 1,1,2,2-Tetrachloroethane ND ug/L 07/13/18 21:19 79-34-52.0 1.5 1 Tetrachloroethene ND ug/L 07/13/18 21:19 127-18-42.0 1.8 1 Toluene ND ug/L 07/13/18 21:19 108-88-32.0 1.6 1 1,2,4-Trichlorobenzene ND ug/L 07/13/18 21:19 120-82-12.0 1.7 1 1,1,1-Trichloroethane ND ug/L 07/13/18 21:19 71-55-62.0 1.9 1 1,1,2-Trichloroethane ND ug/L 07/13/18 21:19 79-00-52.0 1.7 1 Trichloroethene ND ug/L 07/13/18 21:19 79-01-62.0 1.8 1 Trichlorofluoromethane ND ug/L 07/13/18 21:19 75-69-42.0 1.7 1 Vinyl chloride ND ug/L 07/13/18 21:19 75-01-42.0 1.5 1 Surrogates 4-Bromofluorobenzene (S)107 %07/13/18 21:19 460-00-470-130 1 Toluene-d8 (S)110 %07/13/18 21:19 2037-26-570-130 1 1,2-Dichloroethane-d4 (S)103 %07/13/18 21:19 17060-07-070-130 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 08/10/2018 07:37 AM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 17 of 61 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92391708 Little Mountain Creek SW PPL Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 419061 EPA 245.1 Rev 3.0 1994 EPA 245.1 Rev 3.0 1994 245.1 Mercury Associated Lab Samples:92391708001, 92391708002, 92391708003 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:2322893 Associated Lab Samples:92391708001, 92391708002, 92391708003 Matrix:Water AnalyzedMDL Mercury ug/L ND 0.20 07/16/18 09:170.070 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 2322894LABORATORY CONTROL SAMPLE: LCSSpike Mercury ug/L 2.52.5 100 85-115 Parameter Units MS Result % Rec Limits Qual% RecConc. 2322895MATRIX SPIKE & MATRIX SPIKE DUPLICATE: MSSpike Result 92391570001 2322896 MSD Result MSD % Rec RPD RPD Max MSDMS Spike Conc. Mercury ug/L 2.5 92 70-13096 4 202.50.070J 2.4 2.5 Parameter Units MS Result % Rec Limits Qual% RecConc. 2322897MATRIX SPIKE & MATRIX SPIKE DUPLICATE: MSSpike Result 92391792002 2322898 MSD Result MSD % Rec RPD RPD Max MSDMS Spike Conc. Mercury ug/L 2.5 91 70-13094 3 202.50.090J 2.4 2.4 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 08/10/2018 07:37 AM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 18 of 61 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92391708 Little Mountain Creek SW PPL Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 418969 EPA 200.7 Rev 4.4 1994 EPA 200.7 Rev 4.4 1994 200.7 MET Associated Lab Samples:92391708001, 92391708002, 92391708003 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:2322457 Associated Lab Samples:92391708001, 92391708002, 92391708003 Matrix:Water AnalyzedMDL Antimony ug/L ND 5.0 07/14/18 01:563.9 Arsenic ug/L ND 10.0 07/14/18 01:565.0 Beryllium ug/L ND 1.0 07/14/18 01:560.050 Cadmium ug/L ND 1.0 07/14/18 01:560.50 Chromium ug/L ND 5.0 07/14/18 01:562.5 Copper ug/L ND 5.0 07/14/18 01:562.5 Lead ug/L ND 5.0 07/14/18 01:562.5 Nickel ug/L ND 5.0 07/14/18 01:562.5 Selenium ug/L ND 10.0 07/14/18 01:565.0 Silver ug/L ND 5.0 07/14/18 01:562.5 Thallium ug/L ND 10.0 07/14/18 01:565.0 Zinc ug/L ND 10.0 07/14/18 15:442.5 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 2322458LABORATORY CONTROL SAMPLE: LCSSpike Antimony ug/L 472500 94 85-115 Arsenic ug/L 462500 92 85-115 Beryllium ug/L 467500 93 85-115 Cadmium ug/L 460500 92 85-115 Chromium ug/L 462500 92 85-115 Copper ug/L 469500 94 85-115 Lead ug/L 458500 92 85-115 Nickel ug/L 460500 92 85-115 Selenium ug/L 454500 91 85-115 Silver ug/L 235250 94 85-115 Thallium ug/L 462500 92 85-115 Zinc ug/L 462500 92 85-115 Parameter Units MS Result % Rec Limits Qual% RecConc. 2322459MATRIX SPIKE & MATRIX SPIKE DUPLICATE: MSSpike Result 92391643001 2322460 MSD Result MSD % Rec RPD RPD Max MSDMS Spike Conc. Antimony ug/L 500 97 70-13098 1 20500ND484492 Arsenic ug/L 500 96 70-13098 2 20500ND481491 Beryllium ug/L 500 96 70-13097 1 20500ND480483 Cadmium ug/L 500 95 70-13096 1 20500ND475480 Chromium ug/L 500 94 70-13095 2 20500ND471478 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 08/10/2018 07:37 AM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 19 of 61 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92391708 Little Mountain Creek SW PPL Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units MS Result % Rec Limits Qual% RecConc. 2322459MATRIX SPIKE & MATRIX SPIKE DUPLICATE: MSSpike Result 92391643001 2322460 MSD Result MSD % Rec RPD RPD Max MSDMS Spike Conc. Copper ug/L 500 95 70-13097 1 20500ND479486 Lead ug/L 500 93 70-13094 1 20500ND464471 Nickel ug/L 500 93 70-13094 1 205005.9 472 478 Selenium ug/L 500 96 70-13097 1 20500ND480486 Silver ug/L 250 95 70-13097 2 20250ND239243 Thallium ug/L 500 93 70-13094 1 20500ND467471 Zinc ug/L 500 94 70-13095 1 20500206674679 Parameter Units MS Result % Rec Limits Qual% RecConc. 2322461MATRIX SPIKE & MATRIX SPIKE DUPLICATE: MSSpike Result 92391663003 2322462 MSD Result MSD % Rec RPD RPD Max MSDMS Spike Conc. Antimony ug/L 500 99 70-13097 2 20500ND497488 Arsenic ug/L 500 99 70-13097 2 20500ND498488 Beryllium ug/L 500 97 70-13095 2 20500ND484476 Cadmium ug/L 500 96 70-13094 2 20500ND482473 Chromium ug/L 500 96 70-13094 2 20500ND484474 Copper ug/L 500 95 70-13094 1 205000.28 mg/L 754 748 Lead ug/L 500 91 70-13089 1 205000.041 mg/L 494 487 Nickel ug/L 500 92 70-13090 2 20500ND460452 Selenium ug/L 500 96 70-13094 2 20500ND482473 Silver ug/L 250 97 70-13096 1 20250ND243241 Thallium ug/L 500 86 70-13085 2 20500ND432423 Zinc ug/L 500 94 70-13093 1 205000.083mg/L 552 546 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 08/10/2018 07:37 AM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 20 of 61 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92391708 Little Mountain Creek SW PPL Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 419109 EPA 624 EPA 624 624 MSV Associated Lab Samples:92391708001, 92391708002, 92391708003, 92391708004 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:2323313 Associated Lab Samples:92391708001, 92391708002, 92391708003, 92391708004 Matrix:Water AnalyzedMDL 1,1,1-Trichloroethane ug/L ND 2.0 07/13/18 20:111.9 1,1,2,2-Tetrachloroethane ug/L ND 2.0 07/13/18 20:111.5 1,1,2-Trichloroethane ug/L ND 2.0 07/13/18 20:111.7 1,1-Dichloroethane ug/L ND 2.0 07/13/18 20:111.8 1,1-Dichloroethene ug/L ND 2.0 07/13/18 20:111.9 1,2,4-Trichlorobenzene ug/L ND 2.0 07/13/18 20:111.7 1,2-Dichlorobenzene ug/L ND 2.0 07/13/18 20:111.5 1,2-Dichloroethane ug/L ND 2.0 07/13/18 20:111.8 1,2-Dichloropropane ug/L ND 2.0 07/13/18 20:111.7 1,3-Dichlorobenzene ug/L ND 2.0 07/13/18 20:111.5 1,4-Dichlorobenzene ug/L ND 2.0 07/13/18 20:111.5 2-Chloroethylvinyl ether ug/L ND 5.0 07/13/18 20:112.2 Acrolein ug/L ND 5.0 07/13/18 20:111.0 Acrylonitrile ug/L ND 50.0 07/13/18 20:1111.5 Benzene ug/L ND 2.0 07/13/18 20:111.7 Bromodichloromethane ug/L ND 2.0 07/13/18 20:111.7 Bromoform ug/L ND 2.0 07/13/18 20:111.5 Bromomethane ug/L ND 2.0 07/13/18 20:111.0 Carbon tetrachloride ug/L ND 2.0 07/13/18 20:111.9 Chlorobenzene ug/L ND 2.0 07/13/18 20:111.7 Chloroethane ug/L ND 2.0 07/13/18 20:111.6 Chloroform ug/L ND 2.0 07/13/18 20:111.9 Chloromethane ug/L ND 2.0 07/13/18 20:111.5 cis-1,3-Dichloropropene ug/L ND 2.0 07/13/18 20:111.6 Dibromochloromethane ug/L ND 2.0 07/13/18 20:111.8 Ethylbenzene ug/L ND 2.0 07/13/18 20:111.6 Methylene Chloride ug/L ND 2.0 07/13/18 20:111.9 Tetrachloroethene ug/L ND 2.0 07/13/18 20:111.8 Toluene ug/L ND 2.0 07/13/18 20:111.6 trans-1,2-Dichloroethene ug/L ND 2.0 07/13/18 20:111.8 trans-1,3-Dichloropropene ug/L ND 2.0 07/13/18 20:111.6 Trichloroethene ug/L ND 2.0 07/13/18 20:111.8 Trichlorofluoromethane ug/L ND 2.0 07/13/18 20:111.7 Vinyl chloride ug/L ND 2.0 07/13/18 20:111.5 1,2-Dichloroethane-d4 (S)%100 70-130 07/13/18 20:11 4-Bromofluorobenzene (S)%106 70-130 07/13/18 20:11 Toluene-d8 (S)%111 70-130 07/13/18 20:11 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 08/10/2018 07:37 AM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 21 of 61 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92391708 Little Mountain Creek SW PPL Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 2323314LABORATORY CONTROL SAMPLE: LCSSpike 1,1,1-Trichloroethane ug/L 20.620 103 70-130 1,1,2,2-Tetrachloroethane ug/L 19.320 97 60-140 1,1,2-Trichloroethane ug/L 19.520 97 70-130 1,1-Dichloroethane ug/L 19.220 96 70-130 1,1-Dichloroethene ug/L 20.820 104 50-150 1,2,4-Trichlorobenzene ug/L 20.420 102 70-130 1,2-Dichlorobenzene ug/L 19.220 96 65-135 1,2-Dichloroethane ug/L 19.320 97 49-155 1,2-Dichloropropane ug/L 20.920 105 35-165 1,3-Dichlorobenzene ug/L 19.520 98 70-130 1,4-Dichlorobenzene ug/L 19.520 97 65-135 2-Chloroethylvinyl ether ug/L 39.140 98 1-225 Acrolein ug/L 137100 137 60-140 Acrylonitrile ug/L 98.5100 98 60-140 Benzene ug/L 19.920 100 65-135 Bromodichloromethane ug/L 20.920 104 65-135 Bromoform ug/L 19.420 97 70-130 Bromomethane ug/L 18.820 94 15-185 Carbon tetrachloride ug/L 20.420 102 70-130 Chlorobenzene ug/L 19.220 96 65-135 Chloroethane ug/L 17.320 87 40-160 Chloroform ug/L 17.720 88 70-135 Chloromethane ug/L 17.420 87 1-205 cis-1,3-Dichloropropene ug/L 20.520 103 25-175 Dibromochloromethane ug/L 19.820 99 70-135 Ethylbenzene ug/L 19.120 96 60-140 Methylene Chloride ug/L 21.020 105 60-140 Tetrachloroethene ug/L 18.120 90 70-130 Toluene ug/L 19.020 95 70-130 trans-1,2-Dichloroethene ug/L 19.920 99 70-130 trans-1,3-Dichloropropene ug/L 20.420 102 50-150 Trichloroethene ug/L 20.420 102 65-135 Trichlorofluoromethane ug/L 20.420 102 50-150 Vinyl chloride ug/L 19.820 99 5-195 1,2-Dichloroethane-d4 (S)%114 70-130 4-Bromofluorobenzene (S)%101 70-130 Toluene-d8 (S)%99 70-130 Parameter Units MS Result % Rec Limits Qual% RecConc. 2323315MATRIX SPIKE & MATRIX SPIKE DUPLICATE: MSSpike Result 92391643001 2323316 MSD Result MSD % Rec RPD RPD Max MSDMS Spike Conc. 1,1,1-Trichloroethane ug/L 20 122 52-162128 5 3620ND24.3 25.5 1,1,2,2-Tetrachloroethane ug/L 20 104 46-157114 9 6120ND20.9 22.8 1,1,2-Trichloroethane ug/L 20 111 52-150116 4 4520ND22.2 23.2 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 08/10/2018 07:37 AM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 22 of 61 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92391708 Little Mountain Creek SW PPL Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units MS Result % Rec Limits Qual% RecConc. 2323315MATRIX SPIKE & MATRIX SPIKE DUPLICATE: MSSpike Result 92391643001 2323316 MSD Result MSD % Rec RPD RPD Max MSDMS Spike Conc. 1,1-Dichloroethane ug/L 20 111 59-155119 7 4020ND22.2 23.8 1,1-Dichloroethene ug/L 20 121 1-234130 7 3220ND24.3 26.0 1,2,4-Trichlorobenzene ug/L 20 89 70-13097 9 3020ND17.9 19.5 1,2-Dichlorobenzene ug/L 20 101 18-190109 7 5720ND20.3 21.8 1,2-Dichloroethane ug/L 20 110 49-155118 7 4920ND22.1 23.7 1,2-Dichloropropane ug/L 20 118 1-210124 5 5520ND23.5 24.8 1,3-Dichlorobenzene ug/L 20 102 59-156108 5 4320ND20.4 21.6 1,4-Dichlorobenzene ug/L 20 102 18-190109 6 5720ND20.4 21.7 2-Chloroethylvinyl ether ug/L M14001-3050 7140NDNDND Acrolein ug/L 100 111 40-160151 31 60100ND111151 Acrylonitrile ug/L 100 117 40-160119 2 60100ND117119 Benzene ug/L 20 118 37-151127 7 6120ND23.6 25.3 Bromodichloromethane ug/L 20 118 35-155125 6 5620ND23.7 25.0 Bromoform ug/L 20 103 45-169112 8 4220ND20.6 22.4 Bromomethane ug/L 20 67 1-24293 32 6120ND13.5 18.5 Carbon tetrachloride ug/L 20 121 70-140127 5 4120ND24.2 25.5 Chlorobenzene ug/L 20 109 37-160119 9 5320ND21.8 23.8 Chloroethane ug/L 20 98 14-230106 8 7820ND19.5 21.2 Chloroform ug/L 20 100 51-138107 7 5420ND19.9 21.4 Chloromethane ug/L 20 91 1-27396 6 6020ND18.1 19.2 cis-1,3-Dichloropropene ug/L 20 114 1-227121 6 5820ND22.8 24.3 Dibromochloromethane ug/L 20 111 53-149123 10 5020ND22.2 24.5 Ethylbenzene ug/L 20 110 37-162120 9 6320ND22.0 24.0 Methylene Chloride ug/L 20 116 1-221122 4 2820ND23.3 24.3 Tetrachloroethene ug/L 20 104 64-148112 7 3920ND20.9 22.4 Toluene ug/L 20 108 47-150114 5 4120ND21.7 22.8 trans-1,2-Dichloroethene ug/L 20 117 54-156124 6 4520ND23.4 24.8 trans-1,3-Dichloropropene ug/L 20 111 17-183118 6 8620ND22.2 23.6 Trichloroethene ug/L 20 120 70-157128 6 4820ND24.1 25.7 Trichlorofluoromethane ug/L 20 123 17-181125 2 8420ND24.5 25.1 Vinyl chloride ug/L 20 117 1-251124 6 6620ND23.4 24.8 1,2-Dichloroethane-d4 (S)%110 70-130107 4-Bromofluorobenzene (S)%99 70-130101 Toluene-d8 (S)%100 70-13099 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 08/10/2018 07:37 AM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 23 of 61 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92391708 Little Mountain Creek SW PPL Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 419893 EPA 608.3 EPA 608.3 608 PCB Pest Red Vol Associated Lab Samples:92391708001, 92391708002, 92391708003 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:2326921 Associated Lab Samples:92391708001, 92391708002, 92391708003 Matrix:Water AnalyzedMDL 4,4'-DDD ug/L ND 0.050 07/19/18 15:140.050 4,4'-DDE ug/L ND 0.050 07/19/18 15:140.050 4,4'-DDT ug/L ND 0.050 07/19/18 15:140.050 Aldrin ug/L ND 0.050 07/19/18 15:140.050 alpha-BHC ug/L ND 0.050 07/19/18 15:140.050 beta-BHC ug/L ND 0.050 07/19/18 15:140.050 Chlordane (Technical)ug/L ND 0.50 07/19/18 15:140.50 delta-BHC ug/L ND 0.050 07/19/18 15:140.050 Dieldrin ug/L ND 0.050 07/19/18 15:140.050 Endosulfan I ug/L ND 0.050 07/19/18 15:140.050 Endosulfan II ug/L ND 0.050 07/19/18 15:140.050 Endosulfan sulfate ug/L ND 0.050 07/19/18 15:140.050 Endrin ug/L ND 0.050 07/19/18 15:140.050 Endrin aldehyde ug/L ND 0.050 07/19/18 15:140.050 gamma-BHC (Lindane)ug/L ND 0.050 07/19/18 15:140.050 Heptachlor ug/L ND 0.050 07/19/18 15:140.050 Heptachlor epoxide ug/L ND 0.050 07/19/18 15:140.050 PCB-1016 (Aroclor 1016)ug/L ND 0.50 07/19/18 15:140.50 PCB-1221 (Aroclor 1221)ug/L ND 0.50 07/19/18 15:140.50 PCB-1232 (Aroclor 1232)ug/L ND 0.50 07/19/18 15:140.50 PCB-1242 (Aroclor 1242)ug/L ND 0.50 07/19/18 15:140.50 PCB-1248 (Aroclor 1248)ug/L ND 0.50 07/19/18 15:140.50 PCB-1254 (Aroclor 1254)ug/L ND 0.50 07/19/18 15:140.50 PCB-1260 (Aroclor 1260)ug/L ND 0.50 07/19/18 15:140.50 Toxaphene ug/L ND 0.50 07/19/18 15:140.50 Decachlorobiphenyl (S)%84 60-140 07/19/18 15:14 Tetrachloro-m-xylene (S)%81 60-140 07/19/18 15:14 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 2326922LABORATORY CONTROL SAMPLE: LCSSpike 4,4'-DDD ug/L 0.23.25 94 31-141 4,4'-DDE ug/L 0.23.25 91 30-145 4,4'-DDT ug/L 0.23.25 91 25-160 Aldrin ug/L 0.14.25 57 42-140 alpha-BHC ug/L 0.22.25 86 37-140 beta-BHC ug/L 0.19.25 75 17-147 delta-BHC ug/L 0.23.25 92 19-140 Dieldrin ug/L 0.22.25 86 36-146 Endosulfan I ug/L 0.20.25 81 45-153 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 08/10/2018 07:37 AM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 24 of 61 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92391708 Little Mountain Creek SW PPL Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 2326922LABORATORY CONTROL SAMPLE: LCSSpike Endosulfan II ug/L 0.23.25 92 1-202 Endosulfan sulfate ug/L 0.24.25 96 26-144 Endrin ug/L 0.22.25 90 30-147 Endrin aldehyde ug/L 0.23.25 91 50-150 gamma-BHC (Lindane)ug/L 0.22.25 89 32-140 Heptachlor ug/L 0.18.25 73 34-140 Heptachlor epoxide ug/L 0.22.25 87 37-142 Decachlorobiphenyl (S)%90 60-140 Tetrachloro-m-xylene (S)%86 60-140 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 08/10/2018 07:37 AM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 25 of 61 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92391708 Little Mountain Creek SW PPL Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 418950 EPA 625.1 EPA 625.1 625 MSS Associated Lab Samples:92391708001, 92391708002 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:2322394 Associated Lab Samples:92391708001, 92391708002 Matrix:Water AnalyzedMDL 1,2-Diphenylhydrazine ug/L ND 5.0 07/13/18 13:510.90 2,2'-Oxybis(1-chloropropane)ug/L ND 5.0 07/13/18 13:510.95 2,4,6-Trichlorophenol ug/L ND 10.0 07/13/18 13:511.3 2,4-Dichlorophenol ug/L ND 5.0 07/13/18 13:511.7 2,4-Dimethylphenol ug/L ND 10.0 07/13/18 13:511.2 2,4-Dinitrophenol ug/L ND 50.0 07/13/18 13:519.0 2,4-Dinitrotoluene ug/L ND 5.0 07/13/18 13:510.90 2,6-Dinitrotoluene ug/L ND 5.0 07/13/18 13:510.98 2-Chloronaphthalene ug/L ND 5.0 07/13/18 13:510.98 2-Chlorophenol ug/L ND 5.0 07/13/18 13:511.3 2-Methylnaphthalene ug/L ND 5.0 07/13/18 13:510.28 2-Nitrophenol ug/L ND 5.0 07/13/18 13:510.91 3&4-Methylphenol(m&p Cresol)ug/L ND 10.0 N207/13/18 13:512.0 3,3'-Dichlorobenzidine ug/L ND 25.0 07/13/18 13:512.1 4,6-Dinitro-2-methylphenol ug/L ND 20.0 07/13/18 13:512.6 4-Bromophenylphenyl ether ug/L ND 5.0 07/13/18 13:510.82 4-Chloro-3-methylphenol ug/L ND 5.0 07/13/18 13:513.7 4-Chlorophenylphenyl ether ug/L ND 5.0 07/13/18 13:510.87 4-Nitrophenol ug/L ND 50.0 07/13/18 13:514.1 Acenaphthene ug/L ND 5.0 07/13/18 13:510.25 Acenaphthylene ug/L ND 5.0 07/13/18 13:510.21 Anthracene ug/L ND 5.0 07/13/18 13:510.14 Benzidine ug/L ND 50.0 07/13/18 13:515.1 Benzo(a)anthracene ug/L ND 5.0 07/13/18 13:510.33 Benzo(a)pyrene ug/L ND 5.0 07/13/18 13:510.30 Benzo(b)fluoranthene ug/L ND 5.0 07/13/18 13:510.28 Benzo(g,h,i)perylene ug/L ND 5.0 07/13/18 13:510.38 Benzo(k)fluoranthene ug/L ND 5.0 07/13/18 13:510.43 bis(2-Chloroethoxy)methane ug/L ND 10.0 07/13/18 13:510.92 bis(2-Chloroethyl) ether ug/L ND 5.0 07/13/18 13:511.0 bis(2-Ethylhexyl)phthalate ug/L ND 5.0 07/13/18 13:510.79 Butylbenzylphthalate ug/L ND 5.0 07/13/18 13:510.79 Chrysene ug/L ND 5.0 07/13/18 13:510.21 Di-n-butylphthalate ug/L ND 5.0 07/13/18 13:510.75 Di-n-octylphthalate ug/L ND 5.0 07/13/18 13:510.66 Dibenz(a,h)anthracene ug/L ND 5.0 07/13/18 13:510.55 Diethylphthalate ug/L ND 5.0 07/13/18 13:510.58 Dimethylphthalate ug/L ND 5.0 07/13/18 13:510.76 Fluoranthene ug/L ND 5.0 07/13/18 13:510.21 Fluorene ug/L ND 5.0 07/13/18 13:510.21 Hexachloro-1,3-butadiene ug/L ND 5.0 07/13/18 13:510.94 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 08/10/2018 07:37 AM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 26 of 61 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92391708 Little Mountain Creek SW PPL Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:2322394 Associated Lab Samples:92391708001, 92391708002 Matrix:Water AnalyzedMDL Hexachlorobenzene ug/L ND 5.0 07/13/18 13:510.72 Hexachlorocyclopentadiene ug/L ND 10.0 07/13/18 13:510.88 Hexachloroethane ug/L ND 5.0 07/13/18 13:511.1 Indeno(1,2,3-cd)pyrene ug/L ND 5.0 07/13/18 13:510.29 Isophorone ug/L ND 10.0 07/13/18 13:510.89 N-Nitroso-di-n-propylamine ug/L ND 5.0 07/13/18 13:510.99 N-Nitrosodimethylamine ug/L ND 5.0 07/13/18 13:510.91 N-Nitrosodiphenylamine ug/L ND 10.0 07/13/18 13:511.0 Naphthalene ug/L ND 5.0 07/13/18 13:510.34 Nitrobenzene ug/L ND 5.0 07/13/18 13:511.1 Pentachlorophenol ug/L ND 10.0 07/13/18 13:514.6 Phenanthrene ug/L ND 5.0 07/13/18 13:510.22 Phenol ug/L ND 5.0 07/13/18 13:511.9 Pyrene ug/L ND 5.0 07/13/18 13:510.19 2,4,6-Tribromophenol (S)%54 10-137 07/13/18 13:51 2-Fluorobiphenyl (S)%71 15-120 07/13/18 13:51 2-Fluorophenol (S)%35 10-120 07/13/18 13:51 Nitrobenzene-d5 (S)%78 10-120 07/13/18 13:51 Phenol-d6 (S)%23 10-120 07/13/18 13:51 Terphenyl-d14 (S)%79 11-131 07/13/18 13:51 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 2322395LABORATORY CONTROL SAMPLE: LCSSpike 1,2-Diphenylhydrazine ug/L 35.650 71 25-150 2,2'-Oxybis(1-chloropropane)ug/L 32.550 65 36-166 2,4,6-Trichlorophenol ug/L 12.2 L2502437-144 2,4-Dichlorophenol ug/L 21.550 43 39-135 2,4-Dimethylphenol ug/L 33.250 66 32-120 2,4-Dinitrophenol ug/L 13.7J250 5 1-191 2,4-Dinitrotoluene ug/L 38.850 78 39-139 2,6-Dinitrotoluene ug/L 40.350 81 50-158 2-Chloronaphthalene ug/L 30.950 62 60-120 2-Chlorophenol ug/L 22.650 45 23-134 2-Methylnaphthalene ug/L 31.150 62 25-150 2-Nitrophenol ug/L 19.350 39 29-181 3&4-Methylphenol(m&p Cresol)ug/L 23.1 N2504625-150 3,3'-Dichlorobenzidine ug/L 60.8100 61 1-262 4,6-Dinitro-2-methylphenol ug/L 13.4J100 13 1-181 4-Bromophenylphenyl ether ug/L 39.350 79 53-127 4-Chloro-3-methylphenol ug/L 65.5100 66 22-147 4-Chlorophenylphenyl ether ug/L 37.950 76 25-158 4-Nitrophenol ug/L 10J250 4 1-132 Acenaphthene ug/L 34.950 70 47-145 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 08/10/2018 07:37 AM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 27 of 61 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92391708 Little Mountain Creek SW PPL Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 2322395LABORATORY CONTROL SAMPLE: LCSSpike Acenaphthylene ug/L 34.650 69 33-145 Anthracene ug/L 40.250 80 27-133 Benzidine ug/L 22.7J L21002325-150 Benzo(a)anthracene ug/L 33.350 67 33-143 Benzo(a)pyrene ug/L 32.150 64 17-163 Benzo(b)fluoranthene ug/L 30.350 61 24-159 Benzo(g,h,i)perylene ug/L 38.450 77 1-219 Benzo(k)fluoranthene ug/L 32.150 64 11-162 bis(2-Chloroethoxy)methane ug/L 38.650 77 33-184 bis(2-Chloroethyl) ether ug/L 37.550 75 12-158 bis(2-Ethylhexyl)phthalate ug/L 33.050 66 8-158 Butylbenzylphthalate ug/L 35.550 71 1-152 Chrysene ug/L 37.550 75 17-168 Di-n-butylphthalate ug/L 35.550 71 1-120 Di-n-octylphthalate ug/L 30.950 62 4-146 Dibenz(a,h)anthracene ug/L 38.550 77 1-227 Diethylphthalate ug/L 35.450 71 1-120 Dimethylphthalate ug/L 35.250 70 1-120 Fluoranthene ug/L 39.450 79 26-137 Fluorene ug/L 38.050 76 59-121 Hexachloro-1,3-butadiene ug/L 19.150 38 24-120 Hexachlorobenzene ug/L 39.850 80 1-152 Hexachlorocyclopentadiene ug/L 17.650 35 25-150 Hexachloroethane ug/L 18.1 L2503640-120 Indeno(1,2,3-cd)pyrene ug/L 39.150 78 1-171 Isophorone ug/L 32.350 65 21-196 N-Nitroso-di-n-propylamine ug/L 34.850 70 1-230 N-Nitrosodimethylamine ug/L 25.850 52 25-150 N-Nitrosodiphenylamine ug/L 39.250 78 25-150 Naphthalene ug/L 29.650 59 21-133 Nitrobenzene ug/L 36.050 72 35-180 Pentachlorophenol ug/L 14.3100 14 14-176 Phenanthrene ug/L 39.850 80 54-120 Phenol ug/L 14.250 28 5-120 Pyrene ug/L 47.150 94 52-120 2,4,6-Tribromophenol (S)%36 10-137 2-Fluorobiphenyl (S)%69 15-120 2-Fluorophenol (S)%20 10-120 Nitrobenzene-d5 (S)%74 10-120 Phenol-d6 (S)%24 10-120 Terphenyl-d14 (S)%83 11-131 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 08/10/2018 07:37 AM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 28 of 61 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92391708 Little Mountain Creek SW PPL Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units MS Result % Rec Limits Qualifiers% RecConc. 2322396MATRIX SPIKE SAMPLE: MSSpike Result 92391643001 1,2-Diphenylhydrazine ug/L 29.848.1 62 25-150ND 2,2'-Oxybis(1-chloropropane)ug/L 26.448.1 55 36-166ND 2,4,6-Trichlorophenol ug/L 34.848.1 72 37-144ND 2,4-Dichlorophenol ug/L 29.848.1 62 39-135ND 2,4-Dimethylphenol ug/L 27.148.1 56 32-120ND 2,4-Dinitrophenol ug/L 141240 59 1-191ND 2,4-Dinitrotoluene ug/L 35.748.1 74 39-139ND 2,6-Dinitrotoluene ug/L 37.648.1 78 50-158ND 2-Chloronaphthalene ug/L 25.3 M148.1 53 60-120ND 2-Chlorophenol ug/L 26.448.1 55 23-134ND 2-Methylnaphthalene ug/L 26.348.1 55 25-150ND 2-Nitrophenol ug/L 36.048.1 75 29-182ND 3&4-Methylphenol(m&p Cresol)ug/L 18.5 N248.1 39 25-150ND 3,3'-Dichlorobenzidine ug/L 55.296.2 57 1-262ND 4,6-Dinitro-2-methylphenol ug/L 73.296.2 76 1-181ND 4-Bromophenylphenyl ether ug/L 34.848.1 72 53-127ND 4-Chloro-3-methylphenol ug/L 60.196.2 62 22-147ND 4-Chlorophenylphenyl ether ug/L 33.448.1 69 25-158ND 4-Nitrophenol ug/L 57.7240 24 1-132ND Acenaphthene ug/L 29.848.1 62 47-145ND Acenaphthylene ug/L 29.048.1 60 33-145ND Anthracene ug/L 35.748.1 74 27-133ND Benzidine ug/L ND M096.2 4 25-150ND Benzo(a)anthracene ug/L 31.248.1 65 33-143ND Benzo(a)pyrene ug/L 32.248.1 67 17-163ND Benzo(b)fluoranthene ug/L 30.148.1 63 24-159ND Benzo(g,h,i)perylene ug/L 39.048.1 81 1-219ND Benzo(k)fluoranthene ug/L 30.548.1 63 11-162ND bis(2-Chloroethoxy)methane ug/L 31.448.1 65 33-184ND bis(2-Chloroethyl) ether ug/L 29.848.1 62 12-158ND bis(2-Ethylhexyl)phthalate ug/L 30.248.1 63 8-158ND Butylbenzylphthalate ug/L 31.748.1 66 1-152ND Chrysene ug/L 32.048.1 67 17-168ND Di-n-butylphthalate ug/L 32.248.1 67 1-120ND Di-n-octylphthalate ug/L 33.548.1 70 4-146ND Dibenz(a,h)anthracene ug/L 39.448.1 82 1-227ND Diethylphthalate ug/L 32.148.1 67 1-120ND Dimethylphthalate ug/L 31.248.1 65 1-120ND Fluoranthene ug/L 36.448.1 76 26-137ND Fluorene ug/L 33.248.1 69 59-121ND Hexachloro-1,3-butadiene ug/L 19.048.1 40 24-120ND Hexachlorobenzene ug/L 35.148.1 73 1-152ND Hexachlorocyclopentadiene ug/L 17.048.1 35 25-150ND Hexachloroethane ug/L 17.2 M048.1 36 40-120ND Indeno(1,2,3-cd)pyrene ug/L 39.348.1 82 1-171ND Isophorone ug/L 26.548.1 55 21-196ND N-Nitroso-di-n-propylamine ug/L 26.848.1 56 1-230ND REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 08/10/2018 07:37 AM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 29 of 61 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92391708 Little Mountain Creek SW PPL Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units MS Result % Rec Limits Qualifiers% RecConc. 2322396MATRIX SPIKE SAMPLE: MSSpike Result 92391643001 N-Nitrosodimethylamine ug/L 21.348.1 44 25-150ND N-Nitrosodiphenylamine ug/L 33.848.1 70 25-150ND Naphthalene ug/L 25.048.1 52 21-133ND Nitrobenzene ug/L 28.848.1 60 35-180ND Pentachlorophenol ug/L 67.896.2 71 14-176ND Phenanthrene ug/L 34.848.1 72 54-120ND Phenol ug/L 12.048.1 25 5-120ND Pyrene ug/L 35.048.1 73 52-120ND 2,4,6-Tribromophenol (S)%87 10-137 2-Fluorobiphenyl (S)%60 15-120 2-Fluorophenol (S)%35 10-120 Nitrobenzene-d5 (S)%66 10-120 Phenol-d6 (S)%22 10-120 Terphenyl-d14 (S)%56 11-131 Parameter Units Dup Result Max RPD QualifiersRPDResult 266958002 2322397SAMPLE DUPLICATE: 1,2-Diphenylhydrazine ug/L ND 30ND 2,2'-Oxybis(1-chloropropane)ug/L ND 30ND 2,4,6-Trichlorophenol ug/L ND 30ND 2,4-Dichlorophenol ug/L ND 30ND 2,4-Dimethylphenol ug/L ND 30ND 2,4-Dinitrophenol ug/L ND 30ND 2,4-Dinitrotoluene ug/L ND 30ND 2,6-Dinitrotoluene ug/L ND 30ND 2-Chloronaphthalene ug/L ND 30ND 2-Chlorophenol ug/L ND 30ND 2-Methylnaphthalene ug/L ND 30ND 2-Nitrophenol ug/L ND 30ND 3&4-Methylphenol(m&p Cresol)ug/L ND N230ND 3,3'-Dichlorobenzidine ug/L ND 30ND 4,6-Dinitro-2-methylphenol ug/L ND 30ND 4-Bromophenylphenyl ether ug/L ND 30ND 4-Chloro-3-methylphenol ug/L ND 30ND 4-Chlorophenylphenyl ether ug/L ND 30ND 4-Nitrophenol ug/L ND 30ND Acenaphthene ug/L ND 30ND Acenaphthylene ug/L ND 30ND Anthracene ug/L ND 30ND Benzidine ug/L ND 30ND Benzo(a)anthracene ug/L ND 30ND Benzo(a)pyrene ug/L ND 30ND Benzo(b)fluoranthene ug/L ND 30ND Benzo(g,h,i)perylene ug/L ND 30ND REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 08/10/2018 07:37 AM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 30 of 61 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92391708 Little Mountain Creek SW PPL Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units Dup Result Max RPD QualifiersRPDResult 266958002 2322397SAMPLE DUPLICATE: Benzo(k)fluoranthene ug/L ND 30ND bis(2-Chloroethoxy)methane ug/L ND 30ND bis(2-Chloroethyl) ether ug/L ND 30ND bis(2-Ethylhexyl)phthalate ug/L ND 30ND Butylbenzylphthalate ug/L ND 30ND Chrysene ug/L ND 30ND Di-n-butylphthalate ug/L ND 30ND Di-n-octylphthalate ug/L ND 30ND Dibenz(a,h)anthracene ug/L ND 30ND Diethylphthalate ug/L ND 30ND Dimethylphthalate ug/L ND 30ND Fluoranthene ug/L ND 30ND Fluorene ug/L ND 30ND Hexachloro-1,3-butadiene ug/L ND 30ND Hexachlorobenzene ug/L ND 30ND Hexachlorocyclopentadiene ug/L ND 30ND Hexachloroethane ug/L ND 30ND Indeno(1,2,3-cd)pyrene ug/L ND 30ND Isophorone ug/L ND 30ND N-Nitroso-di-n-propylamine ug/L ND 30ND N-Nitrosodimethylamine ug/L ND 30ND N-Nitrosodiphenylamine ug/L ND 30ND Naphthalene ug/L ND 30ND Nitrobenzene ug/L ND 30ND Pentachlorophenol ug/L ND 30ND Phenanthrene ug/L ND 30ND Phenol ug/L ND 30ND Pyrene ug/L ND 30ND 2,4,6-Tribromophenol (S)%81 283 2-Fluorobiphenyl (S)%62 1155 2-Fluorophenol (S)%29 029 Nitrobenzene-d5 (S)%61 658 Phenol-d6 (S)%19 319 Terphenyl-d14 (S)%46 3062 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 08/10/2018 07:37 AM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 31 of 61 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92391708 Little Mountain Creek SW PPL Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 419189 EPA 625.1 EPA 625.1 625 MSS Associated Lab Samples:92391708003 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:2323828 Associated Lab Samples:92391708003 Matrix:Water AnalyzedMDL 1,2-Diphenylhydrazine ug/L ND 5.0 07/18/18 14:540.90 2,2'-Oxybis(1-chloropropane)ug/L ND 5.0 07/18/18 14:540.95 2,4,6-Trichlorophenol ug/L ND 10.0 07/18/18 14:541.3 2,4-Dichlorophenol ug/L ND 5.0 07/18/18 14:541.7 2,4-Dimethylphenol ug/L ND 10.0 07/18/18 14:541.2 2,4-Dinitrophenol ug/L ND 50.0 07/18/18 14:549.0 2,4-Dinitrotoluene ug/L ND 5.0 07/18/18 14:540.90 2,6-Dinitrotoluene ug/L ND 5.0 07/18/18 14:540.98 2-Chloronaphthalene ug/L ND 5.0 07/18/18 14:540.98 2-Chlorophenol ug/L ND 5.0 07/18/18 14:541.3 2-Methylnaphthalene ug/L ND 5.0 07/18/18 14:540.28 2-Nitrophenol ug/L ND 5.0 07/18/18 14:540.91 3&4-Methylphenol(m&p Cresol)ug/L ND 10.0 N207/18/18 14:542.0 3,3'-Dichlorobenzidine ug/L 2.4J 25.0 07/18/18 14:542.1 4,6-Dinitro-2-methylphenol ug/L ND 20.0 07/18/18 14:542.6 4-Bromophenylphenyl ether ug/L ND 5.0 07/18/18 14:540.82 4-Chloro-3-methylphenol ug/L ND 5.0 07/18/18 14:543.7 4-Chlorophenylphenyl ether ug/L ND 5.0 07/18/18 14:540.87 4-Nitrophenol ug/L ND 50.0 07/18/18 14:544.1 Acenaphthene ug/L ND 5.0 07/18/18 14:540.25 Acenaphthylene ug/L ND 5.0 07/18/18 14:540.21 Anthracene ug/L ND 5.0 07/18/18 14:540.14 Benzidine ug/L ND 50.0 07/18/18 14:545.1 Benzo(a)anthracene ug/L 2.6J 5.0 07/18/18 14:540.33 Benzo(a)pyrene ug/L 1.8J 5.0 07/18/18 14:540.30 Benzo(b)fluoranthene ug/L 2.1J 5.0 07/18/18 14:540.28 Benzo(g,h,i)perylene ug/L ND 5.0 07/18/18 14:540.38 Benzo(k)fluoranthene ug/L 2.7J 5.0 07/18/18 14:540.43 bis(2-Chloroethoxy)methane ug/L ND 10.0 07/18/18 14:540.92 bis(2-Chloroethyl) ether ug/L ND 5.0 07/18/18 14:541.0 bis(2-Ethylhexyl)phthalate ug/L 2.4J 5.0 07/18/18 14:540.79 Butylbenzylphthalate ug/L 1.1J 5.0 07/18/18 14:540.79 Chrysene ug/L 3.2J 5.0 07/18/18 14:540.21 Di-n-butylphthalate ug/L ND 5.0 07/18/18 14:540.75 Di-n-octylphthalate ug/L ND 5.0 07/18/18 14:540.66 Dibenz(a,h)anthracene ug/L ND 5.0 07/18/18 14:540.55 Diethylphthalate ug/L ND 5.0 07/18/18 14:540.58 Dimethylphthalate ug/L ND 5.0 07/18/18 14:540.76 Fluoranthene ug/L ND 5.0 07/18/18 14:540.21 Fluorene ug/L ND 5.0 07/18/18 14:540.21 Hexachloro-1,3-butadiene ug/L ND 5.0 07/18/18 14:540.94 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 08/10/2018 07:37 AM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 32 of 61 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92391708 Little Mountain Creek SW PPL Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:2323828 Associated Lab Samples:92391708003 Matrix:Water AnalyzedMDL Hexachlorobenzene ug/L ND 5.0 07/18/18 14:540.72 Hexachlorocyclopentadiene ug/L ND 10.0 07/18/18 14:540.88 Hexachloroethane ug/L ND 5.0 07/18/18 14:541.1 Indeno(1,2,3-cd)pyrene ug/L ND 5.0 07/18/18 14:540.29 Isophorone ug/L ND 10.0 07/18/18 14:540.89 N-Nitroso-di-n-propylamine ug/L ND 5.0 07/18/18 14:540.99 N-Nitrosodimethylamine ug/L ND 5.0 07/18/18 14:540.91 N-Nitrosodiphenylamine ug/L ND 10.0 07/18/18 14:541.0 Naphthalene ug/L ND 5.0 07/18/18 14:540.34 Nitrobenzene ug/L ND 5.0 07/18/18 14:541.1 Pentachlorophenol ug/L ND 10.0 07/18/18 14:544.6 Phenanthrene ug/L ND 5.0 07/18/18 14:540.22 Phenol ug/L ND 5.0 07/18/18 14:541.9 Pyrene ug/L ND 5.0 07/18/18 14:540.19 2,4,6-Tribromophenol (S)%68 10-137 07/18/18 14:54 2-Fluorobiphenyl (S)%60 15-120 07/18/18 14:54 2-Fluorophenol (S)%32 10-120 07/18/18 14:54 Nitrobenzene-d5 (S)%66 10-120 07/18/18 14:54 Phenol-d6 (S)%20 10-120 07/18/18 14:54 Terphenyl-d14 (S)%72 11-131 07/18/18 14:54 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 2323829LABORATORY CONTROL SAMPLE: LCSSpike 1,2-Diphenylhydrazine ug/L 33.050 66 25-150 2,2'-Oxybis(1-chloropropane)ug/L 31.050 62 36-166 2,4,6-Trichlorophenol ug/L 34.950 70 37-144 2,4-Dichlorophenol ug/L 31.050 62 39-135 2,4-Dimethylphenol ug/L 27.950 56 32-120 2,4-Dinitrophenol ug/L 179250 72 1-191 2,4-Dinitrotoluene ug/L 41.850 84 39-139 2,6-Dinitrotoluene ug/L 41.150 82 50-158 2-Chloronaphthalene ug/L 32.550 65 60-120 2-Chlorophenol ug/L 26.850 54 23-134 2-Methylnaphthalene ug/L 34.450 69 25-150 2-Nitrophenol ug/L 37.850 76 29-181 3&4-Methylphenol(m&p Cresol)ug/L 20.7 N2504125-150 3,3'-Dichlorobenzidine ug/L 61.1100 61 1-262 4,6-Dinitro-2-methylphenol ug/L 85.6100 86 1-181 4-Bromophenylphenyl ether ug/L 38.450 77 53-127 4-Chloro-3-methylphenol ug/L 57.7100 58 22-147 4-Chlorophenylphenyl ether ug/L 38.850 78 25-158 4-Nitrophenol ug/L 53.5250 21 1-132 Acenaphthene ug/L 36.550 73 47-145 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 08/10/2018 07:37 AM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 33 of 61 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92391708 Little Mountain Creek SW PPL Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 2323829LABORATORY CONTROL SAMPLE: LCSSpike Acenaphthylene ug/L 36.050 72 33-145 Anthracene ug/L 38.150 76 27-133 Benzidine ug/L ND L2100325-150 Benzo(a)anthracene ug/L 32.250 64 33-143 Benzo(a)pyrene ug/L 40.150 80 17-163 Benzo(b)fluoranthene ug/L 38.150 76 24-159 Benzo(g,h,i)perylene ug/L 46.250 92 1-219 Benzo(k)fluoranthene ug/L 38.850 78 11-162 bis(2-Chloroethoxy)methane ug/L 37.650 75 33-184 bis(2-Chloroethyl) ether ug/L 37.750 75 12-158 bis(2-Ethylhexyl)phthalate ug/L 31.650 63 8-158 Butylbenzylphthalate ug/L 31.250 62 1-152 Chrysene ug/L 32.950 66 17-168 Di-n-butylphthalate ug/L 34.850 70 1-120 Di-n-octylphthalate ug/L 35.050 70 4-146 Dibenz(a,h)anthracene ug/L 46.950 94 1-227 Diethylphthalate ug/L 35.350 71 1-120 Dimethylphthalate ug/L 32.950 66 1-120 Fluoranthene ug/L 38.250 76 26-137 Fluorene ug/L 38.250 76 59-121 Hexachloro-1,3-butadiene ug/L 23.150 46 24-120 Hexachlorobenzene ug/L 38.050 76 1-152 Hexachlorocyclopentadiene ug/L 25.850 52 25-150 Hexachloroethane ug/L 21.650 43 40-120 Indeno(1,2,3-cd)pyrene ug/L 46.150 92 1-171 Isophorone ug/L 32.850 66 21-196 N-Nitroso-di-n-propylamine ug/L 34.950 70 1-230 N-Nitrosodimethylamine ug/L 23.950 48 25-150 N-Nitrosodiphenylamine ug/L 36.250 72 25-150 Naphthalene ug/L 31.250 62 21-133 Nitrobenzene ug/L 34.950 70 35-180 Pentachlorophenol ug/L 60.7100 61 14-176 Phenanthrene ug/L 37.050 74 54-120 Phenol ug/L 13.350 27 5-120 Pyrene ug/L 37.950 76 52-120 2,4,6-Tribromophenol (S)%84 10-137 2-Fluorobiphenyl (S)%68 15-120 2-Fluorophenol (S)%34 10-120 Nitrobenzene-d5 (S)%73 10-120 Phenol-d6 (S)%24 10-120 Terphenyl-d14 (S)%59 11-131 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 08/10/2018 07:37 AM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 34 of 61 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92391708 Little Mountain Creek SW PPL Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units MS Result % Rec Limits Qualifiers% RecConc. 2323830MATRIX SPIKE SAMPLE: MSSpike Result 266987001 1,2-Diphenylhydrazine ug/L 31.349 64 25-150ND 2,2'-Oxybis(1-chloropropane)ug/L 26.349 54 36-166ND 2,4,6-Trichlorophenol ug/L 38.549 78 37-144ND 2,4-Dichlorophenol ug/L 34.249 70 39-135ND 2,4-Dimethylphenol ug/L 28.749 59 32-120ND 2,4-Dinitrophenol ug/L ND245 2 1-191ND 2,4-Dinitrotoluene ug/L 38.449 78 39-139ND 2,6-Dinitrotoluene ug/L 39.549 81 50-158ND 2-Chloronaphthalene ug/L 31.249 64 60-120ND 2-Chlorophenol ug/L 27.249 56 23-134ND 2-Methylnaphthalene ug/L 33.649 69 25-150ND 2-Nitrophenol ug/L 41.649 85 29-182ND 3&4-Methylphenol(m&p Cresol)ug/L 21.4 N2494425-150ND 3,3'-Dichlorobenzidine ug/L 33.998 33 1-262ND 4,6-Dinitro-2-methylphenol ug/L 37.898 39 1-181ND 4-Bromophenylphenyl ether ug/L 36.549 74 53-127ND 4-Chloro-3-methylphenol ug/L 64.798 66 22-147ND 4-Chlorophenylphenyl ether ug/L 36.849 75 25-158ND 4-Nitrophenol ug/L 45.4J245 19 1-132ND Acenaphthene ug/L 33.949 69 47-145ND Acenaphthylene ug/L 33.649 69 33-145ND Anthracene ug/L 35.549 72 27-133ND Benzidine ug/L 7.1J M098725-150ND Benzo(a)anthracene ug/L 31.449 61 33-143ND Benzo(a)pyrene ug/L 35.249 68 17-163ND Benzo(b)fluoranthene ug/L 35.049 66 24-159ND Benzo(g,h,i)perylene ug/L 45.149 92 1-219ND Benzo(k)fluoranthene ug/L 34.749 66 11-162ND bis(2-Chloroethoxy)methane ug/L 34.249 70 33-184ND bis(2-Chloroethyl) ether ug/L 32.249 66 12-158ND bis(2-Ethylhexyl)phthalate ug/L 32.749 63 8-158ND Butylbenzylphthalate ug/L 32.349 66 1-152ND Chrysene ug/L 32.149 62 17-168ND Di-n-butylphthalate ug/L 34.149 69 1-120ND Di-n-octylphthalate ug/L 38.649 73 4-146ND Dibenz(a,h)anthracene ug/L 46.149 94 1-227ND Diethylphthalate ug/L 33.049 67 1-120ND Dimethylphthalate ug/L 32.949 67 1-120ND Fluoranthene ug/L 37.349 76 26-137ND Fluorene ug/L 36.549 74 59-121ND Hexachloro-1,3-butadiene ug/L 23.249 47 24-120ND Hexachlorobenzene ug/L 37.149 76 1-152ND Hexachlorocyclopentadiene ug/L 26.749 54 25-150ND Hexachloroethane ug/L 17.8 M1493640-120ND Indeno(1,2,3-cd)pyrene ug/L 45.149 92 1-171ND Isophorone ug/L 29.149 59 21-196ND N-Nitroso-di-n-propylamine ug/L 30.549 62 1-230ND REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 08/10/2018 07:37 AM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 35 of 61 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92391708 Little Mountain Creek SW PPL Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units MS Result % Rec Limits Qualifiers% RecConc. 2323830MATRIX SPIKE SAMPLE: MSSpike Result 266987001 N-Nitrosodimethylamine ug/L 20.749 42 25-150ND N-Nitrosodiphenylamine ug/L 32.149 66 25-150ND Naphthalene ug/L 28.649 58 21-133ND Nitrobenzene ug/L 33.949 69 35-180ND Pentachlorophenol ug/L 57.898 59 14-176ND Phenanthrene ug/L 35.849 73 54-120ND Phenol ug/L 12.349 25 5-120ND Pyrene ug/L 37.249 76 52-120ND 2,4,6-Tribromophenol (S)%89 10-137 2-Fluorobiphenyl (S)%64 15-120 2-Fluorophenol (S)%30 10-120 Nitrobenzene-d5 (S)%66 10-120 Phenol-d6 (S)%22 10-120 Terphenyl-d14 (S)%45 11-131 Parameter Units Dup Result Max RPD QualifiersRPDResult 92391882003 2323831SAMPLE DUPLICATE: 1,2-Diphenylhydrazine ug/L ND 30ND 2,2'-Oxybis(1-chloropropane)ug/L ND 30ND 2,4,6-Trichlorophenol ug/L ND 30ND 2,4-Dichlorophenol ug/L ND 30ND 2,4-Dimethylphenol ug/L ND 30ND 2,4-Dinitrophenol ug/L ND 30ND 2,4-Dinitrotoluene ug/L ND 30ND 2,6-Dinitrotoluene ug/L ND 30ND 2-Chloronaphthalene ug/L ND 30ND 2-Chlorophenol ug/L ND 30ND 2-Methylnaphthalene ug/L ND 30ND 2-Nitrophenol ug/L ND 30ND 3&4-Methylphenol(m&p Cresol)ug/L ND N230ND 3,3'-Dichlorobenzidine ug/L ND 30ND 4,6-Dinitro-2-methylphenol ug/L ND 30ND 4-Bromophenylphenyl ether ug/L ND 30ND 4-Chloro-3-methylphenol ug/L ND 30ND 4-Chlorophenylphenyl ether ug/L ND 30ND 4-Nitrophenol ug/L ND 30ND Acenaphthene ug/L ND 30ND Acenaphthylene ug/L ND 30ND Anthracene ug/L ND 30ND Benzidine ug/L ND 30ND Benzo(a)anthracene ug/L ND 30ND Benzo(a)pyrene ug/L ND 30ND Benzo(b)fluoranthene ug/L ND 30ND Benzo(g,h,i)perylene ug/L ND 30ND REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 08/10/2018 07:37 AM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 36 of 61 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92391708 Little Mountain Creek SW PPL Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units Dup Result Max RPD QualifiersRPDResult 92391882003 2323831SAMPLE DUPLICATE: Benzo(k)fluoranthene ug/L ND 30ND bis(2-Chloroethoxy)methane ug/L ND 30ND bis(2-Chloroethyl) ether ug/L ND 30ND bis(2-Ethylhexyl)phthalate ug/L 0.99J 30ND Butylbenzylphthalate ug/L ND 30ND Chrysene ug/L ND 30ND Di-n-butylphthalate ug/L ND 30ND Di-n-octylphthalate ug/L ND 30ND Dibenz(a,h)anthracene ug/L ND 30ND Diethylphthalate ug/L ND 30ND Dimethylphthalate ug/L ND 30ND Fluoranthene ug/L ND 30ND Fluorene ug/L ND 30ND Hexachloro-1,3-butadiene ug/L ND 30ND Hexachlorobenzene ug/L ND 30ND Hexachlorocyclopentadiene ug/L ND 30ND Hexachloroethane ug/L ND 30ND Indeno(1,2,3-cd)pyrene ug/L ND 30ND Isophorone ug/L ND 30ND N-Nitroso-di-n-propylamine ug/L ND 30ND N-Nitrosodimethylamine ug/L ND 30ND N-Nitrosodiphenylamine ug/L ND 30ND Naphthalene ug/L ND 30ND Nitrobenzene ug/L ND 30ND Pentachlorophenol ug/L ND 30ND Phenanthrene ug/L ND 30ND Phenol ug/L ND 30ND Pyrene ug/L ND 30ND 2,4,6-Tribromophenol (S)%82 181 2-Fluorobiphenyl (S)%36 1441 2-Fluorophenol (S)%20 421 Nitrobenzene-d5 (S)%39 843 Phenol-d6 (S)%13 313 Terphenyl-d14 (S)%67 763 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 08/10/2018 07:37 AM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 37 of 61 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92391708 Little Mountain Creek SW PPL Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 419703 EPA 420.4 Rev 1.0 1993 EPA 420.4 Rev 1.0 1993 420.4 Phenolics Associated Lab Samples:92391708001, 92391708002, 92391708003 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:2325846 Associated Lab Samples:92391708001, 92391708002, 92391708003 Matrix:Water AnalyzedMDL Phenol mg/L 0.0057J 0.010 B007/19/18 12:300.0050 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 2325847LABORATORY CONTROL SAMPLE: LCSSpike Phenol mg/L 0.049 B0.05 98 90-110 Parameter Units MS Result % Rec Limits Qual% RecConc. 2325848MATRIX SPIKE & MATRIX SPIKE DUPLICATE: MSSpike Result 92391311001 2325849 MSD Result MSD % Rec RPD RPD Max MSDMS Spike Conc. Phenol mg/L B0.05 98 90-110100 1 10.05ND 0.055 0.055 Parameter Units MS Result % Rec Limits Qual% RecConc. 2325850MATRIX SPIKE & MATRIX SPIKE DUPLICATE: MSSpike Result 92391455002 2325851 MSD Result MSD % Rec RPD RPD Max MSDMS Spike Conc. Phenol mg/L B0.05 93 90-11090 2 10.050.014 0.061 0.059 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 08/10/2018 07:37 AM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 38 of 61 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92391708 Little Mountain Creek SW PPL Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 419424 SM 4500-CN-E-2011 SM 4500-CN-E-2011 4500CNE Cyanide, Total Associated Lab Samples:92391708001, 92391708002 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:2324540 Associated Lab Samples:92391708001, 92391708002 Matrix:Water AnalyzedMDL Cyanide mg/L ND 0.0080 07/17/18 14:500.0040 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 2324541LABORATORY CONTROL SAMPLE: LCSSpike Cyanide mg/L 0.10.1 102 80-120 Parameter Units MS Result % Rec Limits Qual% RecConc. 2324542MATRIX SPIKE & MATRIX SPIKE DUPLICATE: MSSpike Result 92391056001 2324543 MSD Result MSD % Rec RPD RPD Max MSDMS Spike Conc. Cyanide mg/L .1 94 80-12090 4 10.1ND 0.094 0.090 Parameter Units MS Result % Rec Limits Qual% RecConc. 2324544MATRIX SPIKE & MATRIX SPIKE DUPLICATE: MSSpike Result 92391398002 2324545 MSD Result MSD % Rec RPD RPD Max MSDMS Spike Conc. Cyanide mg/L .1 96 80-12095 2 10.1ND 0.096 0.095 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 08/10/2018 07:37 AM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 39 of 61 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92391708 Little Mountain Creek SW PPL Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 420558 SM 4500-CN-E-2011 SM 4500-CN-E-2011 4500CNE Cyanide, Total Associated Lab Samples:92391708003 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:2329792 Associated Lab Samples:92391708003 Matrix:Water AnalyzedMDL Cyanide mg/L ND 0.0080 07/25/18 05:560.0040 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 2329793LABORATORY CONTROL SAMPLE: LCSSpike Cyanide mg/L 0.099.1 99 80-120 Parameter Units MS Result % Rec Limits Qual% RecConc. 2329794MATRIX SPIKE & MATRIX SPIKE DUPLICATE: MSSpike Result 92391708003 2329795 MSD Result MSD % Rec RPD RPD Max MSDMS Spike Conc. Cyanide mg/L .1 98 80-12094 4 10.1ND 0.10 0.096 Parameter Units MS Result % Rec Limits Qual% RecConc. 2329796MATRIX SPIKE & MATRIX SPIKE DUPLICATE: MSSpike Result 92391513003 2329797 MSD Result MSD % Rec RPD RPD Max MSDMS Spike Conc. Cyanide mg/L M1,R1.1 69 80-12060 15 10.1ND 0.071 0.061 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 08/10/2018 07:37 AM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 40 of 61 #=QL# QUALIFIERS Pace Project No.: Project: 92391708 Little Mountain Creek SW PPL DEFINITIONS DF - Dilution Factor, if reported, represents the factor applied to the reported data due to dilution of the sample aliquot. ND - Not Detected at or above adjusted reporting limit. TNTC - Too Numerous To Count J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit. MDL - Adjusted Method Detection Limit. PQL - Practical Quantitation Limit. RL - Reporting Limit - The lowest concentration value that meets project requirements for quantitative data with known precision and bias for a specific analyte in a specific matrix. S - Surrogate 1,2-Diphenylhydrazine decomposes to and cannot be separated from Azobenzene using Method 8270. The result for each analyte is a combined concentration. Consistent with EPA guidelines, unrounded data are displayed and have been used to calculate % recovery and RPD values. LCS(D) - Laboratory Control Sample (Duplicate) MS(D) - Matrix Spike (Duplicate) DUP - Sample Duplicate RPD - Relative Percent Difference NC - Not Calculable. SG - Silica Gel - Clean-Up U - Indicates the compound was analyzed for, but not detected. Acid preservation may not be appropriate for 2 Chloroethylvinyl ether. A separate vial preserved to a pH of 4-5 is recommended in SW846 Chapter 4 for the analysis of Acrolein and Acrylonitrile by EPAMethod 8260. N-Nitrosodiphenylamine decomposes and cannot be separated from Diphenylamine using Method 8270. The result reported for each analyte is a combined concentration. Pace Analytical is TNI accredited. Contact your Pace PM for the current list of accredited analytes. TNI - The NELAC Institute. LABORATORIES Pace Analytical Services - AshevillePASI-A Pace Analytical Services - CharlottePASI-C ANALYTE QUALIFIERS Analyte was detected in the associated method blank.B Analyte was detected in an associated blank at a concentration greater than the MDL.B0 Analyte recovery in the laboratory control sample (LCS) was below QC limits. Results for this analyte in associated samples may be biased low.L2 Matrix spike recovery and/or matrix spike duplicate recovery was outside laboratory control limits.M0 Matrix spike recovery exceeded QC limits. Batch accepted based on laboratory control sample (LCS) recovery.M1 The lab does not hold NELAC/TNI accreditation for this parameter.N2 RPD value was outside control limits.R1 Surrogate recovery outside laboratory control limits due to matrix interferences (confirmed by similar results from sample re-analysis).S2 Acid preservation may not be appropriate for the analysis of 2-Chloroethylvinyl ether.c2 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 08/10/2018 07:37 AM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 41 of 61 #=CR# QUALITY CONTROL DATA CROSS REFERENCE TABLE Pace Project No.: Project: 92391708 Little Mountain Creek SW PPL Lab ID Sample ID QC Batch Method QC Batch Analytical Method Analytical Batch 92391708001 419893 420049ABL-SW008-F005 EPA 608.3 EPA 608.3 92391708002 419893 420049ABL-SW008-D005 EPA 608.3 EPA 608.3 92391708003 419893 420049ABL-SW012-F005 EPA 608.3 EPA 608.3 92391708001 418969 419046ABL-SW008-F005 EPA 200.7 Rev 4.4 1994 EPA 200.7 Rev 4.4 1994 92391708002 418969 419046ABL-SW008-D005 EPA 200.7 Rev 4.4 1994 EPA 200.7 Rev 4.4 1994 92391708003 418969 419046ABL-SW012-F005 EPA 200.7 Rev 4.4 1994 EPA 200.7 Rev 4.4 1994 92391708001 419061 419119ABL-SW008-F005 EPA 245.1 Rev 3.0 1994 EPA 245.1 Rev 3.0 1994 92391708002 419061 419119ABL-SW008-D005 EPA 245.1 Rev 3.0 1994 EPA 245.1 Rev 3.0 1994 92391708003 419061 419119ABL-SW012-F005 EPA 245.1 Rev 3.0 1994 EPA 245.1 Rev 3.0 1994 92391708001 418950 419086ABL-SW008-F005 EPA 625.1 EPA 625.1 92391708002 418950 419086ABL-SW008-D005 EPA 625.1 EPA 625.1 92391708003 419189 419796ABL-SW012-F005 EPA 625.1 EPA 625.1 92391708001 419109ABL-SW008-F005 EPA 624 92391708002 419109ABL-SW008-D005 EPA 624 92391708003 419109ABL-SW012-F005 EPA 624 92391708004 419109ABL-TB001-F005 EPA 624 92391708001 419703ABL-SW008-F005 EPA 420.4 Rev 1.0 1993 92391708002 419703ABL-SW008-D005 EPA 420.4 Rev 1.0 1993 92391708003 419703ABL-SW012-F005 EPA 420.4 Rev 1.0 1993 92391708001 419424ABL-SW008-F005 SM 4500-CN-E-2011 92391708002 419424ABL-SW008-D005 SM 4500-CN-E-2011 92391708003 420558ABL-SW012-F005 SM 4500-CN-E-2011 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 08/10/2018 07:37 AM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 42 of 61 Page 43 of 61 Page 44 of 61 Page 45 of 61 Thisreportshouldnotbereproduced,exceptinfull, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Theresultsrelateonlytothesamplesincludedinthisreport. Report of Laboratory Analysis www.pacelabs.com Pace Analytical Services,Inc. 1700 Elm Street Minneapolis, MN 55414 Phone: 612.607.1700 Fax: 612.607.6444 Nicole Gasiorowski PACE Charlotte 9800 Kincey Ave. Huntersville NC 28078 REPORT OF LABORATORY ANALYSIS FOR TCDD This report has been reviewed by: Invoicing & Reporting Options: Report Information: Report Prepared Date: July 25, 2018 PaceProject#:10439455 SampleReceipt Date:07/13/2018 Client Project #:92391708 Client Sub PO #:N/A The report provided has been invoiced as a Level 2 2,3,7,8-TCDD Report. If an upgrade of this report package is requested,an additional charge may be applied. Please review the attached invoice for accuracy and forward anyquestions toNathan Boberg,your Pace Project Manager. State Cert #:27700 Report Prepared for: Page 1 of 15Report No.....10439455_1613TCDD_DFR July 25, 2018 Nathan Boberg, Project Manager (612) 607-6444 (fax) nathan.boberg@pacelabs.com Page 46 of 61 Pace Analytical Services,Inc. 1700 Elm Street Minneapolis, MN 55414 Phone: 612.607.1700 Fax: 612.607.6444 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. This report presents the results from the analyses performed on three samples submitted by a representative of Pace Charlotte. The samples were analyzed for the presence or absence of 2,3,7,8-tetrachlorodibenzo-p-dioxin (2,3,7,8-TCDD) using USEPA Method 1613B. The reporting limits were set to correspond to the lowest calibration point and a nominal 1-Liter sample amount, and the sensitivity was verified by signal-to-noise measurements. The quantitation limits, adjusted for sample extraction amount, may be somewhat higher or lower than the reporting limits provided in this report. The recoveries of the isotopically-labeled TCDD internal standard in the sample extracts ranged from 55-74%. All of the labeled standard recoveries obtained for this project were within the target ranges specified in Method 1613B. Also, since the quantification of the native TCDD was based on isotope dilution, the data were automatically corrected for recovery and accurate values were obtained. A laboratory method blank was prepared and analyzed with each sample batch as part of our routine quality control procedures. The results show the blanks to be free of 2,3,7,8-TCDD at the reporting limits. Laboratory spike samples were also prepared using clean reference matrix that had been fortified with native standard material. The results show that the spiked native TCDD was recovered at 104-111% with a relative percent difference of 6.5%. These results were within the target ranges for the method. Matrix spikes were not prepared with the sample batch. DISCUSSION Page 2 of 15Report No.....10439455_1613TCDD_DFR Page 47 of 61 REPORT OFLABORATORY ANALYSIS This report shallnot bereproduced,exceptin full, withoutthe written consentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Minnesota Laboratory Certifications Authority Certificate #Authority Certificate # A2LA 2926.01 Mississippi MN00064 Alabama 40770 Montana CERT0092 Alaska MN00064 Nebraska NE-OS-18-06 Alaska UST-078 Nevada MN00064 Arizona AZ0014 New Jersey (NE MN002 Arkansas 88-0680 New York (NEL 11647 CNMI Saipan MP0003 New hampshire 2081 California MN00064 North Carolina 27700 Colorado MN00064 North Carolina 530 Connecticut PH-0256 North Dakota R-036 EPA Region 8 8TMS-L Ohio 41244 Florida (NELAP E87605 Ohio VAP CL101 Georgia (EDP)959 Oklahoma 9507 Guam EPA 959 Oregon (ELAP)MN200001 Hawaii MN00064 Oregon (OREL MN300001 Idaho MN00064 Pennsylvania 68-00563 Illinois 200011 Puerto Rico MN00064 Indiana C-MN-01 South Carolina 74003001 Iowa 368 Tennessee TN02818 Kansas E-10167 Texas T104704192 Kentucky 90062 Utah (NELAP)MN00064 Louisiana 03086 Virginia 460163 Louisiana MN00064 Washington C486 Maine MN00064 West Virginia #9952C Maryland 322 West Virginia D 382 Michigan 9909 Wisconsin 999407970 Minnesota 027-053-137 Wyoming 8TMS-L Page 3 of 15Report No.....10439455_1613TCDD_DFR Page 48 of 61 Appendix A Sample Management Pace Analytical Services, Inc.Page 4 of 15Report No.....10439455_1613TCDD_DFR Page 49 of 61 Page 5 of 15Report No.....10439455_1613TCDD_DFR Page 50 of 61 7/16/18 Page 6 of 15Report No.....10439455_1613TCDD_DFR Page 51 of 61 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Reporting Flags A = B = C = D = E = I = J = L = Nn = P = R = S = U = V = X = Y = * = Reporting Limit based on signal to noise Less than 10x higher than method blank level Result obtained from confirmation analysis Result obtained from analysis of diluted sample Exceeds calibration range Interferencepresent Estimated value Suppressive interference,analyte may be biased low Value obtained from additional analysis PCDEInterference Recovery outside target range Peak saturated Analyte not detected Result verified by confirmation analysis %DExceeds limits Calculated using average of daily RFs SeeDiscussion Page 7 of 15Report No.....10439455_1613TCDD_DFR Page 52 of 61 Appendix B Sample Analysis Summary Pace Analytical Services, Inc.Page 8 of 15Report No.....10439455_1613TCDD_DFR Page 53 of 61 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Lab Sample ID Injected By Filename Total Amount Extracted% MoistureDry Weight Extracted ICAL ID CCal Filename(s) Method Blank ID Client's Sample ID ABL-SW008-F00592391708001 F180724B_06 SMT NA1000 mL NA F180405 F180724A_17 BLANK-63557 MatrixDilutionCollected Received Extracted Analyzed WaterNA07/12/2018 07:10 07/13/2018 09:45 07/19/2018 13:00 07/24/2018 18:02 Client - PACE Charlotte Method 1613B Sample Analysis Results NativeIsomers Concpg/L pg/L InternalStandards Addedng's PercentRecoveryEMPCpg/L RL 2,3,7,8-TCDD ND 10 2,3,7,8-TCDD-13C 2.00 74----- Recovery Standard1,2,3,4-TCDD-13C 2.00 NA Cleanup Standard2,3,7,8-TCDD-37Cl4 0.20 90 Conc =Concentration (Totalsinclude 2,3,7,8-substituted isomers). EMPC = Estimated Maximum Possible Concentration ND = Not Detected NA = Not Applicable NC = Not Calculated R =Recovery outside target range E=Exceeds calibration range RL = Reporting Limit Page 9 of 15Report No.....10439455_1613TCDD_DFR Page 54 of 61 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Lab Sample ID Injected By Filename Total Amount Extracted% MoistureDry Weight Extracted ICAL ID CCal Filename(s) Method Blank ID Client's Sample ID ABL-SW008-D00592391708002 U180725A_10 SMT NA1010 mL NA U180405 U180724A_19 BLANK-63557 MatrixDilutionCollected Received Extracted Analyzed WaterNA07/12/2018 07:30 07/13/2018 09:45 07/19/2018 13:00 07/25/2018 12:22 Client - PACE Charlotte Method 1613B Sample Analysis Results NativeIsomers Concpg/L pg/L InternalStandards Addedng's PercentRecoveryEMPCpg/L RL 2,3,7,8-TCDD ND 10 2,3,7,8-TCDD-13C 2.00 63----- Recovery Standard1,2,3,4-TCDD-13C 2.00 NA Cleanup Standard2,3,7,8-TCDD-37Cl4 0.20 77 Conc =Concentration (Totalsinclude 2,3,7,8-substituted isomers). EMPC = Estimated Maximum Possible Concentration ND = Not Detected NA = Not Applicable NC = Not Calculated R =Recovery outside target range E=Exceeds calibration range RL = Reporting Limit Page 10 of 15Report No.....10439455_1613TCDD_DFR Page 55 of 61 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Lab Sample ID Injected By Filename Total Amount Extracted% MoistureDry Weight Extracted ICAL ID CCal Filename(s) Method Blank ID Client's Sample ID ABL-SW012-F00592391708003 U180725A_11 SMT NA957 mL NA U180405 U180724A_19 BLANK-63557 MatrixDilutionCollected Received Extracted Analyzed WaterNA07/12/2018 09:55 07/13/2018 09:45 07/19/2018 13:00 07/25/2018 13:06 Client - PACE Charlotte Method 1613B Sample Analysis Results NativeIsomers Concpg/L pg/L InternalStandards Addedng's PercentRecoveryEMPCpg/L RL 2,3,7,8-TCDD ND 10 2,3,7,8-TCDD-13C 2.00 55----- Recovery Standard1,2,3,4-TCDD-13C 2.00 NA Cleanup Standard2,3,7,8-TCDD-37Cl4 0.20 78 Conc =Concentration (Totalsinclude 2,3,7,8-substituted isomers). EMPC = Estimated Maximum Possible Concentration ND = Not Detected NA = Not Applicable NC = Not Calculated R =Recovery outside target range E=Exceeds calibration range RL = Reporting Limit Page 11 of 15Report No.....10439455_1613TCDD_DFR Page 56 of 61 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Lab Sample ID Injected By Filename Total Amount Extracted ICAL IDCCal Filename(s) BLANK-63557 F180723B_05 SMT 1050 mL F180405F180723B_01 Matrix Dilution Extracted Analyzed Water 07/19/2018 13:00 07/23/2018 16:20 NA Method 1613B Blank Analysis Results Lab Sample Name DFBLKTL Native Isomers pg/L Conc EMPC pg/L pg/L Internal Standards Added ng's Percent Recovery RL 2,3,7,8-TCDD ND -----10 2,3,7,8-TCDD-13C 2.00 59 Recovery Standard1,2,3,4-TCDD-13C 2.00 NA Cleanup Standard2,3,7,8-TCDD-37Cl4 0.20 66 Conc=Concentration(Totalsinclude2,3,7,8-substitutedisomers). EMPC=EstimatedMaximumPossibleConcentrationRL=ReportingLimit Page 12 of 15Report No.....10439455_1613TCDD_DFR Page 57 of 61 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Method 1613B Laboratory Control Spike Results Lab Sample ID Injected By Filename Total Amount Extracted ICAL ID CCal Filename LCS-63558F180723B_02 SMT 1050 mL F180405 F180723B_01 Matrix Dilution Extracted Analyzed Water 07/19/2018 13:00 07/23/2018 14:06 NA Method Blank ID BLANK-63557 Compound Cs Cr Lower Upper Limit Limit %Rec. 2,3,7,8-TCDD 10 10 7.3 14.6 104 2,3,7,8-TCDD-37Cl4 10 8.9 3.7 15.8 89 2,3,7,8-TCDD-13C 100 83 25.0 141.0 83 Cs=ConcentrationSpiked(ng/mL) Cr=ConcentrationRecovered(ng/mL) Rec.=Recovery (ExpressedasPercent) ControlLimitReference:Method 1613,Table 6,10/94Revision R =Recovery outside of control limits Nn=Value obtainedfrom additional analysis *=SeeDiscussion Page 13 of 15Report No.....10439455_1613TCDD_DFR Page 58 of 61 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Method 1613B Laboratory Control Spike Results Lab Sample ID Injected By Filename Total Amount Extracted ICAL ID CCal Filename LCSD-63559F180723B_03 SMT 1010 mL F180405 F180723B_01 Matrix Dilution Extracted Analyzed Water 07/19/2018 13:00 07/23/2018 14:50 NA Method Blank ID BLANK-63557 Compound Cs Cr Lower Upper Limit Limit %Rec. 2,3,7,8-TCDD 10 11 7.3 14.6 111 2,3,7,8-TCDD-37Cl4 10 9.0 3.7 15.8 90 2,3,7,8-TCDD-13C 100 86 25.0 141.0 86 Cs=ConcentrationSpiked(ng/mL) Cr=ConcentrationRecovered(ng/mL) Rec.=Recovery (ExpressedasPercent) ControlLimitReference:Method 1613,Table 6,10/94Revision R =Recovery outside of control limits Nn=Value obtainedfrom additional analysis *=SeeDiscussion Page 14 of 15Report No.....10439455_1613TCDD_DFR Page 59 of 61 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Client Spike 1 ID Spike 1 Filename F180723B_02 LCS-63558 PACE Charlotte Spike Recovery Relative Percent Difference (RPD) Results Spike 2 ID Spike 2 Filename F180723B_03 LCSD-63559 Method 1613B Spike 1 Spike 2 Compound %REC %REC %RPD 2,3,7,8-TCDD 104 111 6.5 %REC = Percent Recovered RPD =The differencebetweenthetwovaluesdivided by the mean value Page 15 of 15Report No.....10439455_1613TCDD_DFR Page 60 of 61 EMSL Analytical, Inc. 2500 Gateway Centre Blvd., Suite 600 Morrisville, NC 27560 Phone/Fax: (919) 465-3900 / (919) 465-3950 http://www.EMSL.com / raleighlab@emsl.com pace54 291805971EMSL Order ID: Customer ID: Customer PO: Project ID: Attn: Proj:92391708/Little Mountain Creek SW PPL Phone: (704) 875-9092 Fax: (704) 875-9091 Collected: 07/12/2018 Received: 07/13/2018 Analyzed: 07/27/2018 Nicole Gasiorowski Pace Analytical Services, LLC 9800 Kincey Avenue, Suite 100 Huntersville, NC 28078 Test Report: Determination of Asbestos Structures >10µm in Drinking Water Performed by the 100.2 Method (EPA 600/R-94/134) Sample Filtration Date/Time Sample ID Client / EMSL ASBESTOS Confidence Limits ConcentrationAnalytical Sensitivity Fibers Detected Asbestos TypesArea Analyzed (mm²) Effective Filter Area (mm²) Original Sample Vol. Filtered (ml)MFL (million fibers per liter) 7/14/2018 09:12 AM 12635 0.2600ABL-SW008-F005 291805971-0001 0.97ND <0.97 0.00 - 3.60None Detected 7/14/2018 09:12 AM 126320 0.2600ABL-SW008-D005 291805971-0002 0.24ND <0.24 0.00 - 0.90None Detected 7/14/2018 09:12 AM 126310 0.2600ABL-SW012-F005 291805971-0003 0.49ND <0.49 0.00 - 1.80None Detected Page 1 of 1Test Report: TEM100.2-7.35.11 Printed: 7/27/2018 10:58AM Analyst(s) Billy Barnes, Asbestos Lab Manager or Other Approved SignatoryAny questions please contact Billy Barnes. Sample collection and containers provided by the client, acceptable bottle blank level is defined as ≤0.01MFL>10um. ND=None Detected. This report may not be reproduced, except in full, without written permission by EMSL Analytical, Inc. The test results contained within this report meet the requirements of NELAC unless otherwise noted. This report relates only to the samples reported above. Samples received in good condition unless otherwise noted. Samples analyzed by EMSL Analytical, Inc. Morrisville, NC Alicia Folgar (3) Initial report from: 07/27/2018 10:58:34 Page 61 of 61 #=CL# September 04, 2018 LIMS USE: FR - MICHAEL WORDEN LIMS OBJECT ID: 92391608 92391608 Project: Pace Project No.: RE: Michael W. Worden Environeering, Inc. 16100 Cairnway Suite 320 Houston, TX 77084 Eastern Drainage Ditch - Sed Dear Michael Worden: Enclosed are the analytical results for sample(s) received by the laboratory on July 11, 2018. The results relate only to the samples included in this report. Results reported herein conform to the most current, applicable TNI/NELAC standards and the laboratory's Quality Assurance Manual, where applicable, unless otherwise noted in the body of the report. This revision was issued on 8/20/18 to report updated 8270 with passing internal standards after several reanalyses. If you have any questions concerning this report, please feel free to contact me. Sincerely, Nicole Gasiorowski nicole.gasiorowski@pacelabs.com Project Manager (704)875-9092 Enclosures REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 1 of 81 #=CP# CERTIFICATIONS Pace Project No.: Project: 92391608 Eastern Drainage Ditch - Sed Charlotte Certification IDs 9800 Kincey Ave. Ste 100, Huntersville, NC 28078 Louisiana/NELAP Certification # LA170028 North Carolina Drinking Water Certification #: 37706 North Carolina Field Services Certification #: 5342 North Carolina Wastewater Certification #: 12 South Carolina Certification #: 99006001 Florida/NELAP Certification #: E87627 Kentucky UST Certification #: 84 Virginia/VELAP Certification #: 460221 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 2 of 81 #=SS# SAMPLE SUMMARY Pace Project No.: Project: 92391608 Eastern Drainage Ditch - Sed Lab ID Sample ID Matrix Date Collected Date Received 92391608001 ABL-SD010-F005 Solid 07/11/18 00:00 07/11/18 16:35 92391608002 ABL-SD011-F005 Solid 07/11/18 00:00 07/11/18 16:35 92391608003 ABL-SD012-F005 Solid 07/11/18 00:00 07/11/18 16:35 92391608004 ABL-EB001-F005 Water 07/11/18 00:00 07/11/18 16:35 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 3 of 81 #=SA# SAMPLE ANALYTE COUNT Pace Project No.: Project: 92391608 Eastern Drainage Ditch - Sed Lab ID Sample ID Method Analytes Reported LaboratoryAnalysts 92391608001 ABL-SD010-F005 EPA 8082A 8 PASI-CNU1 EPA 8270D by SIM 21 PASI-CPKS ASTM D2974-87 1 PASI-CKDF 92391608002 ABL-SD011-F005 EPA 8082A 8 PASI-CNU1 EPA 8270D by SIM 21 PASI-CPKS ASTM D2974-87 1 PASI-CKDF 92391608003 ABL-SD012-F005 EPA 8082A 8 PASI-CNU1 EPA 8270D by SIM 21 PASI-CPKS ASTM D2974-87 1 PASI-CKDF 92391608004 ABL-EB001-F005 EPA 8082A 8 PASI-CNU1 EPA 8270D by SIM 20 PASI-CRES REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 4 of 81 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92391608 Eastern Drainage Ditch - Sed Sample:ABL-SD010-F005 Lab ID:92391608001 Collected:07/11/18 00:00 Received:07/11/18 16:35 Matrix:Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 8082A Preparation Method: EPA 35468082 GCS PCB PCB-1016 (Aroclor 1016)ND ug/kg 07/13/18 16:56 12674-11-207/12/18 13:3548.0 21.8 1 PCB-1221 (Aroclor 1221)ND ug/kg 07/13/18 16:56 11104-28-207/12/18 13:3548.0 21.8 1 PCB-1232 (Aroclor 1232)ND ug/kg 07/13/18 16:56 11141-16-507/12/18 13:3548.0 21.8 1 PCB-1242 (Aroclor 1242)ND ug/kg 07/13/18 16:56 53469-21-907/12/18 13:3548.0 21.8 1 PCB-1248 (Aroclor 1248)ND ug/kg 07/13/18 16:56 12672-29-607/12/18 13:3548.0 21.8 1 PCB-1254 (Aroclor 1254)ND ug/kg 07/13/18 16:56 11097-69-107/12/18 13:3548.0 21.8 1 PCB-1260 (Aroclor 1260)ND ug/kg 07/13/18 16:56 11096-82-507/12/18 13:3548.0 21.8 1 Surrogates Decachlorobiphenyl (S)59 %07/13/18 16:56 2051-24-307/12/18 13:3521-132 1 Analytical Method: EPA 8270D by SIM Preparation Method: EPA 35468270 MSSV MW PAH by SIM Acenaphthene 3.5J ug/kg 08/11/18 03:09 83-32-907/12/18 16:1014.8 2.2 1 Acenaphthylene ND ug/kg 08/11/18 03:09 208-96-807/12/18 16:1014.8 1.9 1 Anthracene 7.4J ug/kg 08/11/18 03:09 120-12-707/12/18 16:1014.8 2.1 1 Benzo(a)anthracene 40.0 ug/kg 08/11/18 03:09 56-55-307/12/18 16:1014.8 1.1 1 Benzo(a)pyrene 45.6 ug/kg 08/11/18 03:09 50-32-807/12/18 16:1014.8 1.6 1 Benzo(b)fluoranthene 41.9 ug/kg 08/11/18 03:09 205-99-207/12/18 16:1014.8 0.99 1 Benzo(g,h,i)perylene 23.0 ug/kg 08/11/18 03:09 191-24-207/12/18 16:1014.8 3.9 1 Benzo(k)fluoranthene 15.8 ug/kg 08/11/18 03:09 207-08-907/12/18 16:1014.8 2.2 1 Chrysene 37.2 ug/kg 08/11/18 03:09 218-01-907/12/18 16:1014.8 2.7 1 Dibenz(a,h)anthracene ND ug/kg 08/11/18 03:09 53-70-307/12/18 16:1014.8 2.7 1 Fluoranthene 53.9 ug/kg 08/11/18 03:09 206-44-007/12/18 16:1014.8 1.2 1 Fluorene 2.8J ug/kg 08/11/18 03:09 86-73-707/12/18 16:1014.8 2.4 1 Indeno(1,2,3-cd)pyrene 21.7 ug/kg 08/11/18 03:09 193-39-507/12/18 16:1014.8 4.2 1 1-Methylnaphthalene ND ug/kg 08/11/18 03:09 90-12-007/12/18 16:1014.8 1.8 1 2-Methylnaphthalene 2.3J ug/kg 08/11/18 03:09 91-57-6 B07/12/18 16:1014.8 1.6 1 Naphthalene ND ug/kg 08/11/18 03:09 91-20-307/12/18 16:1014.8 3.4 1 Phenanthrene 29.5 ug/kg 08/11/18 03:09 85-01-807/12/18 16:1014.8 2.2 1 Pyrene 44.5 ug/kg 08/11/18 03:09 129-00-007/12/18 16:1014.8 2.7 1 Surrogates Nitrobenzene-d5 (S)55 %08/11/18 03:09 4165-60-007/12/18 16:1010-128 1 2-Fluorobiphenyl (S)43 %08/11/18 03:09 321-60-807/12/18 16:1010-110 1 Terphenyl-d14 (S)61 %08/11/18 03:09 1718-51-007/12/18 16:1039-119 1 Analytical Method: ASTM D2974-87Percent Moisture Percent Moisture 32.8 %07/13/18 11:490.10 0.10 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 09/04/2018 12:06 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 5 of 81 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92391608 Eastern Drainage Ditch - Sed Sample:ABL-SD011-F005 Lab ID:92391608002 Collected:07/11/18 00:00 Received:07/11/18 16:35 Matrix:Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 8082A Preparation Method: EPA 35468082 GCS PCB PCB-1016 (Aroclor 1016)ND ug/kg 07/13/18 17:17 12674-11-207/12/18 13:3558.3 26.5 1 PCB-1221 (Aroclor 1221)ND ug/kg 07/13/18 17:17 11104-28-207/12/18 13:3558.3 26.5 1 PCB-1232 (Aroclor 1232)ND ug/kg 07/13/18 17:17 11141-16-507/12/18 13:3558.3 26.5 1 PCB-1242 (Aroclor 1242)ND ug/kg 07/13/18 17:17 53469-21-907/12/18 13:3558.3 26.5 1 PCB-1248 (Aroclor 1248)ND ug/kg 07/13/18 17:17 12672-29-607/12/18 13:3558.3 26.5 1 PCB-1254 (Aroclor 1254)ND ug/kg 07/13/18 17:17 11097-69-107/12/18 13:3558.3 26.5 1 PCB-1260 (Aroclor 1260)ND ug/kg 07/13/18 17:17 11096-82-507/12/18 13:3558.3 26.5 1 Surrogates Decachlorobiphenyl (S)60 %07/13/18 17:17 2051-24-307/12/18 13:3521-132 1 Analytical Method: EPA 8270D by SIM Preparation Method: EPA 35468270 MSSV MW PAH by SIM Acenaphthene 26.2 ug/kg 08/11/18 03:55 83-32-907/12/18 16:1017.5 2.6 1 Acenaphthylene ND ug/kg 08/11/18 03:55 208-96-807/12/18 16:1017.5 2.3 1 Anthracene 56.3 ug/kg 08/11/18 03:55 120-12-707/12/18 16:1017.5 2.5 1 Benzo(a)anthracene 287 ug/kg 08/11/18 03:55 56-55-307/12/18 16:1017.5 1.2 1 Benzo(a)pyrene 319 ug/kg 08/11/18 03:55 50-32-807/12/18 16:1017.5 1.9 1 Benzo(b)fluoranthene 286 ug/kg 08/11/18 03:55 205-99-207/12/18 16:1017.5 1.2 1 Benzo(g,h,i)perylene 146 ug/kg 08/11/18 03:55 191-24-207/12/18 16:1017.5 4.6 1 Benzo(k)fluoranthene 109 ug/kg 08/11/18 03:55 207-08-907/12/18 16:1017.5 2.6 1 Chrysene 254 ug/kg 08/11/18 03:55 218-01-907/12/18 16:1017.5 3.2 1 Dibenz(a,h)anthracene 13.1J ug/kg 08/11/18 03:55 53-70-307/12/18 16:1017.5 3.2 1 Fluoranthene 381 ug/kg 08/11/18 03:55 206-44-007/12/18 16:1017.5 1.5 1 Fluorene 21.5 ug/kg 08/11/18 03:55 86-73-707/12/18 16:1017.5 2.8 1 Indeno(1,2,3-cd)pyrene 137 ug/kg 08/11/18 03:55 193-39-507/12/18 16:1017.5 4.9 1 1-Methylnaphthalene 2.7J ug/kg 08/11/18 03:55 90-12-007/12/18 16:1017.5 2.1 1 2-Methylnaphthalene 4.2J ug/kg 08/11/18 03:55 91-57-607/12/18 16:1017.5 1.9 1 Naphthalene 5.9J ug/kg 08/11/18 03:55 91-20-307/12/18 16:1017.5 4.0 1 Phenanthrene 235 ug/kg 08/11/18 03:55 85-01-807/12/18 16:1017.5 2.6 1 Pyrene 307 ug/kg 08/11/18 03:55 129-00-007/12/18 16:1017.5 3.2 1 Surrogates Nitrobenzene-d5 (S)52 %08/11/18 03:55 4165-60-007/12/18 16:1010-128 1 2-Fluorobiphenyl (S)35 %08/11/18 03:55 321-60-807/12/18 16:1010-110 1 Terphenyl-d14 (S)38 %08/11/18 03:55 1718-51-0 S007/12/18 16:1039-119 1 Analytical Method: ASTM D2974-87Percent Moisture Percent Moisture 42.4 %07/13/18 11:490.10 0.10 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 09/04/2018 12:06 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 6 of 81 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92391608 Eastern Drainage Ditch - Sed Sample:ABL-SD012-F005 Lab ID:92391608003 Collected:07/11/18 00:00 Received:07/11/18 16:35 Matrix:Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 8082A Preparation Method: EPA 35468082 GCS PCB PCB-1016 (Aroclor 1016)ND ug/kg 07/13/18 17:37 12674-11-207/12/18 13:3548.0 21.8 1 PCB-1221 (Aroclor 1221)ND ug/kg 07/13/18 17:37 11104-28-207/12/18 13:3548.0 21.8 1 PCB-1232 (Aroclor 1232)ND ug/kg 07/13/18 17:37 11141-16-507/12/18 13:3548.0 21.8 1 PCB-1242 (Aroclor 1242)ND ug/kg 07/13/18 17:37 53469-21-907/12/18 13:3548.0 21.8 1 PCB-1248 (Aroclor 1248)ND ug/kg 07/13/18 17:37 12672-29-607/12/18 13:3548.0 21.8 1 PCB-1254 (Aroclor 1254)ND ug/kg 07/13/18 17:37 11097-69-107/12/18 13:3548.0 21.8 1 PCB-1260 (Aroclor 1260)ND ug/kg 07/13/18 17:37 11096-82-507/12/18 13:3548.0 21.8 1 Surrogates Decachlorobiphenyl (S)77 %07/13/18 17:37 2051-24-307/12/18 13:3521-132 1 Analytical Method: EPA 8270D by SIM Preparation Method: EPA 35468270 MSSV MW PAH by SIM Acenaphthene ND ug/kg 08/11/18 03:32 83-32-907/12/18 16:1014.4 2.2 1 Acenaphthylene ND ug/kg 08/11/18 03:32 208-96-807/12/18 16:1014.4 1.9 1 Anthracene 3.6J ug/kg 08/11/18 03:32 120-12-707/12/18 16:1014.4 2.0 1 Benzo(a)anthracene 17.1 ug/kg 08/11/18 03:32 56-55-307/12/18 16:1014.4 1.0 1 Benzo(a)pyrene 19.1 ug/kg 08/11/18 03:32 50-32-807/12/18 16:1014.4 1.6 1 Benzo(b)fluoranthene 17.6 ug/kg 08/11/18 03:32 205-99-207/12/18 16:1014.4 0.96 1 Benzo(g,h,i)perylene 10.0J ug/kg 08/11/18 03:32 191-24-207/12/18 16:1014.4 3.7 1 Benzo(k)fluoranthene 8.0J ug/kg 08/11/18 03:32 207-08-907/12/18 16:1014.4 2.2 1 Chrysene 16.2 ug/kg 08/11/18 03:32 218-01-907/12/18 16:1014.4 2.6 1 Dibenz(a,h)anthracene ND ug/kg 08/11/18 03:32 53-70-307/12/18 16:1014.4 2.6 1 Fluoranthene 23.2 ug/kg 08/11/18 03:32 206-44-007/12/18 16:1014.4 1.2 1 Fluorene ND ug/kg 08/11/18 03:32 86-73-707/12/18 16:1014.4 2.3 1 Indeno(1,2,3-cd)pyrene 9.3J ug/kg 08/11/18 03:32 193-39-507/12/18 16:1014.4 4.0 1 1-Methylnaphthalene ND ug/kg 08/11/18 03:32 90-12-007/12/18 16:1014.4 1.7 1 2-Methylnaphthalene ND ug/kg 08/11/18 03:32 91-57-607/12/18 16:1014.4 1.6 1 Naphthalene ND ug/kg 08/11/18 03:32 91-20-307/12/18 16:1014.4 3.3 1 Phenanthrene 14.0J ug/kg 08/11/18 03:32 85-01-807/12/18 16:1014.4 2.2 1 Pyrene 18.1 ug/kg 08/11/18 03:32 129-00-007/12/18 16:1014.4 2.6 1 Surrogates Nitrobenzene-d5 (S)54 %08/11/18 03:32 4165-60-007/12/18 16:1010-128 1 2-Fluorobiphenyl (S)40 %08/11/18 03:32 321-60-807/12/18 16:1010-110 1 Terphenyl-d14 (S)59 %08/11/18 03:32 1718-51-007/12/18 16:1039-119 1 Analytical Method: ASTM D2974-87Percent Moisture Percent Moisture 31.2 %07/13/18 11:490.10 0.10 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 09/04/2018 12:06 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 7 of 81 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92391608 Eastern Drainage Ditch - Sed Sample:ABL-EB001-F005 Lab ID:92391608004 Collected:07/11/18 00:00 Received:07/11/18 16:35 Matrix:Water Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 8082A Preparation Method: EPA 3510C8082 GCS PCB RVE PCB-1016 (Aroclor 1016)ND ug/L 07/16/18 19:05 12674-11-207/12/18 19:400.42 0.42 1 PCB-1221 (Aroclor 1221)ND ug/L 07/16/18 19:05 11104-28-207/12/18 19:400.42 0.42 1 PCB-1232 (Aroclor 1232)ND ug/L 07/16/18 19:05 11141-16-507/12/18 19:400.42 0.42 1 PCB-1242 (Aroclor 1242)ND ug/L 07/16/18 19:05 53469-21-907/12/18 19:400.42 0.42 1 PCB-1248 (Aroclor 1248)ND ug/L 07/16/18 19:05 12672-29-607/12/18 19:400.42 0.42 1 PCB-1254 (Aroclor 1254)ND ug/L 07/16/18 19:05 11097-69-107/12/18 19:400.42 0.42 1 PCB-1260 (Aroclor 1260)ND ug/L 07/16/18 19:05 11096-82-507/12/18 19:400.42 0.42 1 Surrogates Decachlorobiphenyl (S)32 %07/16/18 19:05 2051-24-307/12/18 19:4010-132 1 Analytical Method: EPA 8270D by SIM Preparation Method: EPA 3511 Leachate Method/Date: EPA 1312; 07/19/18 10:52 8270 SPLP SIM PAH Low Volume Acenaphthene ND ug/L 07/20/18 16:31 83-32-907/20/18 07:400.50 0.50 1 Acenaphthylene ND ug/L 07/20/18 16:31 208-96-807/20/18 07:400.50 0.50 1 Anthracene ND ug/L 07/20/18 16:31 120-12-707/20/18 07:400.050 0.050 1 Benzo(a)anthracene ND ug/L 07/20/18 16:31 56-55-307/20/18 07:400.050 0.050 1 Benzo(a)pyrene ND ug/L 07/20/18 16:31 50-32-807/20/18 07:400.10 0.10 1 Benzo(b)fluoranthene ND ug/L 07/20/18 16:31 205-99-207/20/18 07:400.050 0.050 1 Benzo(g,h,i)perylene ND ug/L 07/20/18 16:31 191-24-207/20/18 07:400.20 0.20 1 Benzo(k)fluoranthene ND ug/L 07/20/18 16:31 207-08-907/20/18 07:400.20 0.20 1 Chrysene ND ug/L 07/20/18 16:31 218-01-907/20/18 07:400.10 0.10 1 Dibenz(a,h)anthracene ND ug/L 07/20/18 16:31 53-70-307/20/18 07:400.15 0.15 1 Fluoranthene ND ug/L 07/20/18 16:31 206-44-007/20/18 07:400.30 0.30 1 Fluorene ND ug/L 07/20/18 16:31 86-73-707/20/18 07:400.31 0.31 1 Indeno(1,2,3-cd)pyrene ND ug/L 07/20/18 16:31 193-39-507/20/18 07:400.050 0.050 1 1-Methylnaphthalene ND ug/L 07/20/18 16:31 90-12-007/20/18 07:402.0 2.0 1 2-Methylnaphthalene ND ug/L 07/20/18 16:31 91-57-607/20/18 07:402.0 2.0 1 Naphthalene ND ug/L 07/20/18 16:31 91-20-307/20/18 07:401.5 1.5 1 Phenanthrene ND ug/L 07/20/18 16:31 85-01-807/20/18 07:400.20 0.20 1 Pyrene ND ug/L 07/20/18 16:31 129-00-007/20/18 07:400.10 0.10 1 Surrogates Nitrobenzene-d5 (S)113 %07/20/18 16:31 4165-60-007/20/18 07:4070-130 1 2-Fluorobiphenyl (S)84 %07/20/18 16:31 321-60-807/20/18 07:4070-130 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 09/04/2018 12:06 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 8 of 81 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92391608 Eastern Drainage Ditch - Sed Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 418714 EPA 3510C EPA 8082A 8082 GCS PCB Associated Lab Samples:92391608004 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:2321052 Associated Lab Samples:92391608004 Matrix:Water AnalyzedMDL PCB-1016 (Aroclor 1016)ug/L ND 0.50 07/16/18 23:330.50 PCB-1221 (Aroclor 1221)ug/L ND 0.50 07/16/18 23:330.50 PCB-1232 (Aroclor 1232)ug/L ND 0.50 07/16/18 23:330.50 PCB-1242 (Aroclor 1242)ug/L ND 0.50 07/16/18 23:330.50 PCB-1248 (Aroclor 1248)ug/L ND 0.50 07/16/18 23:330.50 PCB-1254 (Aroclor 1254)ug/L ND 0.50 07/16/18 23:330.50 PCB-1260 (Aroclor 1260)ug/L ND 0.50 07/16/18 23:330.50 Decachlorobiphenyl (S)%73 10-132 07/16/18 23:33 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 2321053LABORATORY CONTROL SAMPLE & LCSD: LCSSpike LCSD % Rec RPD Max RPD LCSD Result 2321054 PCB-1016 (Aroclor 1016)ug/L 3.65 72 50-150683.4 6 30 PCB-1260 (Aroclor 1260)ug/L 4.05 80 50-150743.7 9 30 Decachlorobiphenyl (S)%76 10-13281 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 09/04/2018 12:06 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 9 of 81 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92391608 Eastern Drainage Ditch - Sed Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 418842 EPA 3546 EPA 8082A 8082 GCS PCB Associated Lab Samples:92391608001, 92391608002, 92391608003 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:2321763 Associated Lab Samples:92391608001, 92391608002, 92391608003 Matrix:Solid AnalyzedMDL PCB-1016 (Aroclor 1016)ug/kg ND 32.8 07/13/18 13:4314.9 PCB-1221 (Aroclor 1221)ug/kg ND 32.8 07/13/18 13:4314.9 PCB-1232 (Aroclor 1232)ug/kg ND 32.8 07/13/18 13:4314.9 PCB-1242 (Aroclor 1242)ug/kg ND 32.8 07/13/18 13:4314.9 PCB-1248 (Aroclor 1248)ug/kg ND 32.8 07/13/18 13:4314.9 PCB-1254 (Aroclor 1254)ug/kg ND 32.8 07/13/18 13:4314.9 PCB-1260 (Aroclor 1260)ug/kg ND 32.8 07/13/18 13:4314.9 Decachlorobiphenyl (S)%95 21-132 07/13/18 13:43 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 2321764LABORATORY CONTROL SAMPLE & LCSD: LCSSpike LCSD % Rec RPD Max RPD LCSD Result 2321765 PCB-1016 (Aroclor 1016)ug/kg 131167 79 31-12088147 11 30 PCB-1260 (Aroclor 1260)ug/kg 148167 89 32-120102170 14 30 Decachlorobiphenyl (S)%102 21-132113 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 09/04/2018 12:06 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 10 of 81 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92391608 Eastern Drainage Ditch - Sed Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 418920 EPA 3546 EPA 8270D by SIM 8270 MSSV PAH by SIM Associated Lab Samples:92391608001, 92391608002, 92391608003 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:2322225 Associated Lab Samples:92391608001, 92391608002, 92391608003 Matrix:Solid AnalyzedMDL 1-Methylnaphthalene ug/kg ND 9.9 07/17/18 10:361.2 2-Methylnaphthalene ug/kg 1.7J 9.9 07/17/18 10:361.1 Acenaphthene ug/kg ND 9.9 07/17/18 10:361.5 Acenaphthylene ug/kg ND 9.9 07/17/18 10:361.3 Anthracene ug/kg ND 9.9 07/17/18 10:361.4 Benzo(a)anthracene ug/kg ND 9.9 07/17/18 10:360.70 Benzo(a)pyrene ug/kg ND 9.9 07/17/18 10:361.1 Benzo(b)fluoranthene ug/kg ND 9.9 07/17/18 10:360.66 Benzo(g,h,i)perylene ug/kg ND 9.9 07/17/18 10:362.6 Benzo(k)fluoranthene ug/kg ND 9.9 07/17/18 10:361.5 Chrysene ug/kg ND 9.9 07/17/18 10:361.8 Dibenz(a,h)anthracene ug/kg ND 9.9 07/17/18 10:361.8 Fluoranthene ug/kg ND 9.9 07/17/18 10:360.82 Fluorene ug/kg ND 9.9 07/17/18 10:361.6 Indeno(1,2,3-cd)pyrene ug/kg ND 9.9 07/17/18 10:362.8 Naphthalene ug/kg ND 9.9 07/17/18 10:362.3 Phenanthrene ug/kg ND 9.9 07/17/18 10:361.5 Pyrene ug/kg ND 9.9 07/17/18 10:361.8 2-Fluorobiphenyl (S)%47 10-110 07/17/18 10:36 Nitrobenzene-d5 (S)%53 10-128 07/17/18 10:36 Terphenyl-d14 (S)%59 39-119 07/17/18 10:36 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 2322226LABORATORY CONTROL SAMPLE: LCSSpike 1-Methylnaphthalene ug/kg 19.433.8 57 44-130 2-Methylnaphthalene ug/kg 20.133.8 59 41-134 Acenaphthene ug/kg 20.033.8 59 52-123 Acenaphthylene ug/kg 18.433.8 55 49-116 Anthracene ug/kg 19.233.8 57 41-133 Benzo(a)anthracene ug/kg 19.533.8 58 56-130 Benzo(a)pyrene ug/kg 18.533.8 55 51-136 Benzo(b)fluoranthene ug/kg 17.833.8 53 37-149 Benzo(g,h,i)perylene ug/kg 17.133.8 51 39-127 Benzo(k)fluoranthene ug/kg 21.233.8 63 45-139 Chrysene ug/kg 20.233.8 60 59-127 Dibenz(a,h)anthracene ug/kg 18.133.8 54 37-139 Fluoranthene ug/kg 19.133.8 57 53-132 Fluorene ug/kg 18.833.8 56 45-127 Indeno(1,2,3-cd)pyrene ug/kg 18.933.8 56 35-145 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 09/04/2018 12:06 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 11 of 81 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92391608 Eastern Drainage Ditch - Sed Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 2322226LABORATORY CONTROL SAMPLE: LCSSpike Naphthalene ug/kg 20.233.8 60 45-123 Phenanthrene ug/kg 18.833.8 56 50-125 Pyrene ug/kg 18.933.8 56 52-132 2-Fluorobiphenyl (S)%58 10-110 Nitrobenzene-d5 (S)%66 10-128 Terphenyl-d14 (S)%66 39-119 Parameter Units MS Result % Rec Limits Qualifiers% RecConc. 2322227MATRIX SPIKE SAMPLE: MSSpike Result 35403561001 1-Methylnaphthalene ug/kg 11.2 M133.3 33 50-1501.2U 2-Methylnaphthalene ug/kg 11.5 M133.3 34 50-1501.1U Acenaphthene ug/kg 11.5 M133.3 35 50-1501.5U Acenaphthylene ug/kg 10.5 M133.3 32 50-1501.3U Anthracene ug/kg 11.0 M133.3 33 50-1501.4U Benzo(a)anthracene ug/kg 11.3 M133.3 34 50-1500.72U Benzo(a)pyrene ug/kg 10.6 M133.3 32 50-1501.1U Benzo(b)fluoranthene ug/kg 11.0 M133.3 33 50-1500.68U Benzo(g,h,i)perylene ug/kg 9.2J M133.3 27 50-1502.6U Benzo(k)fluoranthene ug/kg 11.7 M133.3 35 50-1501.5U Chrysene ug/kg 11.2 M133.3 34 50-1501.8U Dibenz(a,h)anthracene ug/kg 9.7J M133.3 29 50-1501.8U Fluoranthene ug/kg 11.2 M133.3 34 50-1500.84U Fluorene ug/kg 11.0 M133.3 33 50-1501.6U Indeno(1,2,3-cd)pyrene ug/kg 10.3 M133.3 31 50-1502.8U Naphthalene ug/kg 11.4 M133.3 34 50-1502.3U Phenanthrene ug/kg 11.0 M133.3 33 50-1501.5U Pyrene ug/kg 11.2 M133.3 33 50-1501.8U 2-Fluorobiphenyl (S)%32 10-110 Nitrobenzene-d5 (S)%36 10-128 Terphenyl-d14 (S)%S23539-119 Parameter Units Dup Result Max RPD QualifiersRPDResult 35403557001 2322228SAMPLE DUPLICATE: 1-Methylnaphthalene ug/kg 157 IO330161 2-Methylnaphthalene ug/kg 25.3J IO3022.5J Acenaphthene ug/kg ND IO3063.0J Acenaphthylene ug/kg ND IO3014.3U Anthracene ug/kg 112 27 30147 Benzo(a)anthracene ug/kg ND IO307.8U Benzo(a)pyrene ug/kg ND IO3012.1U Benzo(b)fluoranthene ug/kg ND IO307.4U Benzo(g,h,i)perylene ug/kg ND IO3028.5U REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 09/04/2018 12:06 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 12 of 81 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92391608 Eastern Drainage Ditch - Sed Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units Dup Result Max RPD QualifiersRPDResult 35403557001 2322228SAMPLE DUPLICATE: Benzo(k)fluoranthene ug/kg ND IO3016.5U Chrysene ug/kg ND IO3019.7U Dibenz(a,h)anthracene ug/kg ND IO3019.7U Fluoranthene ug/kg 101J IO3092.1J Fluorene ug/kg 77.9J IO30128 Indeno(1,2,3-cd)pyrene ug/kg ND IO3030.7U Naphthalene ug/kg 105J IO3095.7J Phenanthrene ug/kg ND IO3016.5U Pyrene ug/kg 283 IO1030255 2-Fluorobiphenyl (S)%0 S40 Nitrobenzene-d5 (S)%0 D3,P3,S40 Terphenyl-d14 (S)%0 S40 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 09/04/2018 12:06 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 13 of 81 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92391608 Eastern Drainage Ditch - Sed Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 420210 EPA 3511 EPA 8270D by SIM 8270 SPLP SIM PAH Low Volume Associated Lab Samples:92391608004 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:2328166 Associated Lab Samples:92391608004 Matrix:Water AnalyzedMDL 1-Methylnaphthalene ug/L ND 2.0 07/20/18 15:492.0 2-Methylnaphthalene ug/L ND 2.0 07/20/18 15:492.0 Acenaphthene ug/L ND 0.50 07/20/18 15:490.50 Acenaphthylene ug/L ND 0.50 07/20/18 15:490.50 Anthracene ug/L ND 0.050 07/20/18 15:490.050 Benzo(a)anthracene ug/L ND 0.050 07/20/18 15:490.050 Benzo(a)pyrene ug/L ND 0.10 07/20/18 15:490.10 Benzo(b)fluoranthene ug/L ND 0.050 07/20/18 15:490.050 Benzo(g,h,i)perylene ug/L ND 0.20 07/20/18 15:490.20 Benzo(k)fluoranthene ug/L ND 0.20 07/20/18 15:490.20 Chrysene ug/L ND 0.10 07/20/18 15:490.10 Dibenz(a,h)anthracene ug/L ND 0.15 07/20/18 15:490.15 Fluoranthene ug/L ND 0.30 07/20/18 15:490.30 Fluorene ug/L ND 0.31 07/20/18 15:490.31 Indeno(1,2,3-cd)pyrene ug/L ND 0.050 07/20/18 15:490.050 Naphthalene ug/L ND 1.5 07/20/18 15:491.5 Phenanthrene ug/L ND 0.20 07/20/18 15:490.20 Pyrene ug/L ND 0.10 07/20/18 15:490.10 2-Fluorobiphenyl (S)%77 70-130 07/20/18 15:49 Nitrobenzene-d5 (S)%94 70-130 07/20/18 15:49 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 2328167LABORATORY CONTROL SAMPLE: LCSSpike 1-Methylnaphthalene ug/L 2.42.5 94 70-130 2-Methylnaphthalene ug/L 2.32.5 91 70-130 Acenaphthene ug/L 2.52.5 99 70-130 Acenaphthylene ug/L 2.42.5 95 70-130 Anthracene ug/L 2.62.5 103 70-130 Benzo(a)anthracene ug/L 2.42.5 98 70-130 Benzo(a)pyrene ug/L 2.52.5 100 70-130 Benzo(b)fluoranthene ug/L 2.42.5 95 70-130 Benzo(g,h,i)perylene ug/L 2.32.5 94 70-130 Benzo(k)fluoranthene ug/L 2.42.5 97 70-130 Chrysene ug/L 2.72.5 107 70-130 Dibenz(a,h)anthracene ug/L 2.52.5 101 70-130 Fluoranthene ug/L 2.52.5 102 70-130 Fluorene ug/L 2.52.5 99 70-130 Indeno(1,2,3-cd)pyrene ug/L 2.62.5 106 70-130 Naphthalene ug/L 2.02.5 82 70-130 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 09/04/2018 12:06 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 14 of 81 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92391608 Eastern Drainage Ditch - Sed Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 2328167LABORATORY CONTROL SAMPLE: LCSSpike Phenanthrene ug/L 2.42.5 95 70-130 Pyrene ug/L 2.52.5 100 70-130 2-Fluorobiphenyl (S)%79 70-130 Nitrobenzene-d5 (S)%107 70-130 Parameter Units MS Result % Rec Limits Qualifiers% RecConc. 2328168MATRIX SPIKE SAMPLE: MSSpike Result 92391608004 1-Methylnaphthalene ug/L 2.82.5 113 70-130ND 2-Methylnaphthalene ug/L 2.82.5 111 70-130ND Acenaphthene ug/L 3.02.5 120 70-130ND Acenaphthylene ug/L 2.92.5 117 70-130ND Anthracene ug/L 3.22.5 126 70-130ND Benzo(a)anthracene ug/L 2.82.5 113 70-130ND Benzo(a)pyrene ug/L 2.82.5 113 70-130ND Benzo(b)fluoranthene ug/L 2.82.5 111 70-130ND Benzo(g,h,i)perylene ug/L 2.62.5 104 70-130ND Benzo(k)fluoranthene ug/L 2.72.5 109 70-130ND Chrysene ug/L 3.12.5 126 70-130ND Dibenz(a,h)anthracene ug/L 2.82.5 112 70-130ND Fluoranthene ug/L 3.02.5 119 70-130ND Fluorene ug/L 3.02.5 122 70-130ND Indeno(1,2,3-cd)pyrene ug/L 2.92.5 115 70-130ND Naphthalene ug/L 2.52.5 98 70-130ND Phenanthrene ug/L 2.92.5 114 70-130ND Pyrene ug/L 2.92.5 117 70-130ND 2-Fluorobiphenyl (S)%84 70-130 Nitrobenzene-d5 (S)%115 70-130 Parameter Units Dup Result Max RPD QualifiersRPDResult 92391628001 2328169SAMPLE DUPLICATE: 1-Methylnaphthalene ug/L ND 30ND 2-Methylnaphthalene ug/L ND 30ND Acenaphthene ug/L ND 30ND Acenaphthylene ug/L ND 30ND Anthracene ug/L ND 30ND Benzo(a)anthracene ug/L ND 30ND Benzo(a)pyrene ug/L ND 30ND Benzo(b)fluoranthene ug/L ND 30ND Benzo(g,h,i)perylene ug/L ND 30ND Benzo(k)fluoranthene ug/L ND 30ND Chrysene ug/L ND 30ND Dibenz(a,h)anthracene ug/L ND 30ND REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 09/04/2018 12:06 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 15 of 81 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92391608 Eastern Drainage Ditch - Sed Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units Dup Result Max RPD QualifiersRPDResult 92391628001 2328169SAMPLE DUPLICATE: Fluoranthene ug/L ND 30ND Fluorene ug/L ND 30ND Indeno(1,2,3-cd)pyrene ug/L ND 30ND Naphthalene ug/L ND 30ND Phenanthrene ug/L ND 30ND Pyrene ug/L ND 30ND 2-Fluorobiphenyl (S)%85 779 Nitrobenzene-d5 (S)%109 1110 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 09/04/2018 12:06 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 16 of 81 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92391608 Eastern Drainage Ditch - Sed Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 418835 ASTM D2974-87 ASTM D2974-87 Dry Weight/Percent Moisture Associated Lab Samples:92391608001, 92391608002, 92391608003 Parameter Units Dup Result Max RPD QualifiersRPDResult 92391517001 2321705SAMPLE DUPLICATE: Percent Moisture %11.4 1 2511.2 Parameter Units Dup Result Max RPD QualifiersRPDResult 35403559001 2321729SAMPLE DUPLICATE: Percent Moisture %50.4 3 2551.8 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 09/04/2018 12:06 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 17 of 81 #=QL# QUALIFIERS Pace Project No.: Project: 92391608 Eastern Drainage Ditch - Sed DEFINITIONS DF - Dilution Factor, if reported, represents the factor applied to the reported data due to dilution of the sample aliquot. ND - Not Detected at or above adjusted reporting limit. TNTC - Too Numerous To Count J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit. MDL - Adjusted Method Detection Limit. PQL - Practical Quantitation Limit. RL - Reporting Limit - The lowest concentration value that meets project requirements for quantitative data with known precision and bias for a specific analyte in a specific matrix. S - Surrogate 1,2-Diphenylhydrazine decomposes to and cannot be separated from Azobenzene using Method 8270. The result for each analyte is a combined concentration. Consistent with EPA guidelines, unrounded data are displayed and have been used to calculate % recovery and RPD values. LCS(D) - Laboratory Control Sample (Duplicate) MS(D) - Matrix Spike (Duplicate) DUP - Sample Duplicate RPD - Relative Percent Difference NC - Not Calculable. SG - Silica Gel - Clean-Up U - Indicates the compound was analyzed for, but not detected. Acid preservation may not be appropriate for 2 Chloroethylvinyl ether. A separate vial preserved to a pH of 4-5 is recommended in SW846 Chapter 4 for the analysis of Acrolein and Acrylonitrile by EPAMethod 8260. N-Nitrosodiphenylamine decomposes and cannot be separated from Diphenylamine using Method 8270. The result reported for each analyte is a combined concentration. Pace Analytical is TNI accredited. Contact your Pace PM for the current list of accredited analytes. TNI - The NELAC Institute. LABORATORIES Pace Analytical Services - CharlottePASI-C WORKORDER QUALIFIERS WO: 92391608 This revision was issued on 8/30/18 to correctly report the 8270 fraction for two samples. Upon the reanalysis upload, the data for two samples was switched. This has been corrected.[2] ANALYTE QUALIFIERS Analyte was detected in the associated method blank.B Sample was diluted due to the presence of high levels of non-target analytes or other matrix interference.D3 The internal standard response was outside the laboratory acceptance limits confirmed by reanalysis. The results reported are from the most QC compliant analysis.IO Matrix spike recovery exceeded QC limits. Batch accepted based on laboratory control sample (LCS) recovery.M1 Sample extract could not be concentrated to the routine final volume, resulting in elevated reporting limits.P3 Surrogate recovery outside laboratory control limits.S0 Surrogate recovery outside laboratory control limits due to matrix interferences (confirmed by similar results from sample re-analysis).S2 Surrogate recovery not evaluated against control limits due to sample dilution.S4 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 09/04/2018 12:06 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 18 of 81 #=CR# QUALITY CONTROL DATA CROSS REFERENCE TABLE Pace Project No.: Project: 92391608 Eastern Drainage Ditch - Sed Lab ID Sample ID QC Batch Method QC Batch Analytical Method Analytical Batch 92391608004 418714 419331ABL-EB001-F005 EPA 3510C EPA 8082A 92391608001 418842 419076ABL-SD010-F005 EPA 3546 EPA 8082A 92391608002 418842 419076ABL-SD011-F005 EPA 3546 EPA 8082A 92391608003 418842 419076ABL-SD012-F005 EPA 3546 EPA 8082A 92391608001 418920 419465ABL-SD010-F005 EPA 3546 EPA 8270D by SIM 92391608002 418920 419465ABL-SD011-F005 EPA 3546 EPA 8270D by SIM 92391608003 418920 419465ABL-SD012-F005 EPA 3546 EPA 8270D by SIM 92391608004 420210 420315ABL-EB001-F005 EPA 3511 EPA 8270D by SIM 92391608001 418835ABL-SD010-F005 ASTM D2974-87 92391608002 418835ABL-SD011-F005 ASTM D2974-87 92391608003 418835ABL-SD012-F005 ASTM D2974-87 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 09/04/2018 12:06 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 19 of 81 Page 20 of 81 Page 21 of 81 Page 22 of 81 Thisreportshouldnotbereproduced,exceptinfull, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Theresultsrelateonlytothesamplesincludedinthisreport. Report of Laboratory Analysis www.pacelabs.com Pace Analytical Services,Inc. 1700 Elm Street Minneapolis, MN 55414 Phone: 612.607.1700 Fax: 612.607.6444 Client - Charlotte PACE Charlotte 9800 Kincey Ave. Huntersville NC 28078 REPORT OF LABORATORY ANALYSIS FOR PCBs This report has been reviewed by: Invoicing & Reporting Options: Report Information: Report Prepared Date: July 25, 2018 Pace Project #: 10439419 Sample Receipt Date: 07/13/2018 Client Project #: 92391608 Alcoa-Badin Works Client Sub PO #: N/A The report provided has been invoiced as a Level 2 PCB Report. If an upgrade of this report package is requested, an additional charge may be applied. Please review the attached invoice for accuracy and forward anyquestions toNathan Boberg,your Pace Project Manager. State Cert #: 27700 Report Prepared for: Page 1 of 59Report No.....10439419_1668_209_DFR July 25, 2018 Scott Unze, Project Manager (612) 607-6383 (612) 607-6444 (fax) scott.unze@pacelabs.com Page 23 of 81 Pace Analytical Services,Inc. 1700 Elm Street Minneapolis, MN 55414 Phone: 612.607.1700 Fax: 612.607.6444 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. This report presents the results from the analyses performed on four samples submitted by a representative of Pace Analytical - NC. The samples were analyzed for the presence or absence of polychlorinated biphenyl (PCB) congeners using USEPA Method 1668A. Reporting limits were set to 25-75 parts-per-trillion for solids and 0.25-0.75 parts-per-trillion for water. These results were adjusted for the amount of sample extracted. The dilution level noted on the data tables is being adjusted to allow the correct data flags to populate the electronic deliverables as well as the data tables. Samples and MDL extracts were analyzed at elevated volumes. That volume is being treated as a 1x dilution for calculation purposes, with larger dilutions being factored from that volume. The standard reporting limits were not adjusted since the limits remained within the calibration range even after dilutions were applied. The recoveries of the isotopically-labeled PCB internal standards in the sample extracts ranged from 43-115%. All of the labeled standard recoveries obtained for this project were within the target ranges specified in Method 1668A. Since the quantification of the native congeners was based on isotope dilution and internal standard methodology, the data were automatically corrected for variation in recovery and accurate values were obtained. Incorrect isotope ratios were obtained for selected PCB congeners. The affected congeners were flagged "I" on the results table. Any associated target analyte detections were provided under the estimated maximum possible concentration (EMPC) column on the results table. If EMPCs were reported for congeners with WHO toxicity factors, the EMPC levels were included in the calculation of the toxic equivalence. A laboratory method blank was prepared and analyzed with each sample batch as part of our routine quality control procedures. The results show the blanks to be free of PCB congeners at the reporting limits. This indicates that the sample preparation procedures did not significantly contribute to the PCB content of the sample material. Laboratory spike samples were also prepared with the sample batch using reference material that had been fortified with native standards. The results show that the spiked native compounds were recovered at 71-125%, with relative percent differences of 0.0-22.5%. The RPD for the DiCB congeners in solid matrix spike pair was above the 20% limit used by Pace analytical. This could indicate a higher than normal variability in the Di-CB results from the associated sample extracts. However, these values were DISCUSSION Page 2 of 59Report No.....10439419_1668_209_DFR Page 24 of 81 Pace Analytical Services,Inc. 1700 Elm Street Minneapolis, MN 55414 Phone: 612.607.1700 Fax: 612.607.6444 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. within method limits. Matrix spikes were not extracted with these sample batches. DISCUSSION Page 3 of 59Report No.....10439419_1668_209_DFR Page 25 of 81 REPORT OFLABORATORY ANALYSIS This report shallnot bereproduced,exceptin full, withoutthe written consentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Report No.....10439419 Minnesota Laboratory Certifications Authority Certificate #Authority Certificate # A2LA 2926.01 Mississippi MN00064 Alabama 40770 Montana CERT0092 Alaska MN00064 Nebraska NE-OS-18-06 Alaska UST-078 Nevada MN00064 Arizona AZ0014 New Jersey (NE MN002 Arkansas 88-0680 New York (NEL 11647 CNMI Saipan MP0003 New hampshire 2081 California MN00064 North Carolina 27700 Colorado MN00064 North Carolina 530 Connecticut PH-0256 North Dakota R-036 EPA Region 8 8TMS-L Ohio 41244 Florida (NELAP E87605 Ohio VAP CL101 Georgia (EDP)959 Oklahoma 9507 Guam EPA 959 Oregon (ELAP)MN200001 Hawaii MN00064 Oregon (OREL MN300001 Idaho MN00064 Pennsylvania 68-00563 Illinois 200011 Puerto Rico MN00064 Indiana C-MN-01 South Carolina 74003001 Iowa 368 Tennessee TN02818 Kansas E-10167 Texas T104704192 Kentucky 90062 Utah (NELAP)MN00064 Louisiana 03086 Virginia 460163 Louisiana MN00064 Washington C486 Maine MN00064 West Virginia #9952C Maryland 322 West Virginia D 382 Michigan 9909 Wisconsin 999407970 Minnesota 027-053-137 Wyoming 8TMS-L Page 4 of 59Report No.....10439419_1668_209_DFR Page 26 of 81 Appendix A Sample Management Pace Analytical Services, Inc.Page 5 of 59Report No.....10439419_1668_209_DFR Page 27 of 81 Page 6 of 59Report No.....10439419_1668_209_DFR Page 28 of 81 7/16/18 Page 7 of 59Report No.....10439419_1668_209_DFR Page 29 of 81 10439419 Page 8 of 59Report No.....10439419_1668_209_DFR Page 30 of 81 8/16/18 Page 9 of 59Report No.....10439419_1668_209_DFR Page 31 of 81 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Report No.....10439419 Reporting Flags A = B = C = D = E = I = J = L = Nn = P = R = S = U = V = X = Y = * = Reporting Limit based on signal to noise Less than 10x higher than method blank level Result obtained from confirmation analysis Result obtained from analysis of diluted sample Exceeds calibration range Interferencepresent Estimated value Suppressive interference,analyte may be biased low Value obtained from additional analysis PCDEInterference Recovery outside target range Peak saturated Analyte not detected Result verified by confirmation analysis %DExceeds limits Calculated using average of daily RFs SeeDiscussion Page 10 of 59Report No.....10439419_1668_209_DFR Page 32 of 81 Appendix B Sample Analysis Summary Pace Analytical Services, Inc.Page 11 of 59Report No.....10439419_1668_209_DFR Page 33 of 81 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Client - PACE Charlotte Client's Sample ID Lab Sample ID Filename Injected ByTotal Amount Extracted% Moisture Dry Weight Extracted ICAL ID CCal Filename(s)Method Blank ID BLANK-63507P180724B_01 P180724B02 10.1 g 32.815.1 gCVS P180724B_09 92391608001 ABL-SD010-F005 MatrixDilution Collected Received ExtractedAnalyzed 07/25/2018 06:2007/17/2018 15:00 07/13/2018 09:45 07/11/2018 NASolid Method 1668A Polychlorobiphenyl Sample Analysis Results PCB Isomer RT % Recoveryng's Foundng's AddedIUPACRatio LabeledAnalytes13C-2-MoCB 1 2.97 2.09.575 1.12 5613C-4-MoCB 3 3.22 2.012.415 1.15 5713C-2,2'-DiCB 4 1.61 2.012.726 1.14 5713C-4,4'-DiCB 15 1.68 2.019.924 1.31 6513C-2,2',6-TrCB 19 0.95 2.016.570 1.59 8013C-3,4,4'-TrCB 37 0.96 2.027.691 1.45 7213C-2,2',6,6'-TeCB 54 0.86 2.020.229 1.28 6413C-3,4,4',5-TeCB 81 0.84 2.034.840 1.44 7213C-3,3',4,4'-TeCB 77 0.80 2.035.426 1.46 7313C-2,2',4,6,6'-PeCB 104 1.75 2.026.282 1.25 6213C-2,3,3',4,4'-PeCB 105 1.59 2.039.003 1.50 7513C-2,3,4,4',5-PeCB 114 1.65 2.038.332 1.53 7713C-2,3',4,4',5-PeCB 118 1.54 2.037.762 1.48 7413C-2,3',4,4',5'-PeCB 123 1.59 2.037.427 1.47 7313C-3,3',4,4',5-PeCB 126 1.60 2.042.189 1.62 8113C-2,2',4,4',6,6'-HxCB 155 1.32 2.032.324 1.17 5913C-HxCB(156/157)156/157 1.30 4.045.213 2.90 7313C-2,3',4,4',5,5'-HxCB 167 1.27 2.044.022 1.40 7013C-3,3',4,4',5,5'-HxCB 169 1.28 2.048.516 1.56 7813C-2,2',3,4',5,6,6'-HpCB 188 1.12 2.038.249 1.14 5713C-2,3,3',4,4',5,5'-HpCB 189 1.16 2.051.022 1.46 7313C-2,2',3,3',5,5',6,6'-OcCB 202 0.89 2.043.720 1.33 6713C-2,3,3',4,4',5,5',6-OcCB 205 0.84 2.053.091 1.36 6813C-2,2',3,3',4,4',5,5',6-NoCB 206 0.80 2.054.514 1.39 6913C-2,2',3,3',4,5,5',6,6'-NoCB 208 0.83 2.050.505 1.31 6613C--DeCB 209 0.68 2.055.979 1.48 74 CleanupStandards13C-2,4,4'-TrCB 28 1.13 2.023.298 1.48 7413C-2,3,3',5,5'-PeCB 111 1.57 2.035.359 1.35 6713C-2,2',3,3',5,5',6-HpCB 178 0.97 2.041.368 1.45 72 Recovery Standards13C-2,5-DiCB 9 1.63 2.015.192 NA NA13C-2,2',5,5'-TeCB 52 0.83 2.025.276 NA NA13C-2,2',4,5,5'-PeCB 101 1.62 2.032.592 NA NA13C-2,2',3,4,4',5'-HxCB 138 1.30 2.040.948 NA NA13C-2,2',3,3',4,4',5,5'-OcCB 194 0.84 2.052.703 NA NA Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = NanogramsResultsreportedonadryweightbasis Page 12 of 59Report No.....10439419_1668_209_DFR Page 34 of 81 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses Resultsreportedon a dryweight basis ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SD010-F005 P180724B_09Lab Sample ID 92391608001 Co-elutions RT ng/Kg EMLEMPCConcentration ng/KgIUPACRatio ng/Kg 1 ---ND------25.02---ND------25.03---ND------25.0 4 1.45 66.812.750 ---25.05---ND------25.06---ND------25.07---ND------25.081.50 10816.234 ---25.0 9 ---ND------25.010---ND------25.011---ND------245 12 12/13 ---ND------50.01312/13 ---ND------50.014---ND------25.0 15 1.47 65.219.936 ---33.016---ND------25.0171.08 10219.373 ---25.01818/30 ---ND------50.019---ND------25.02020/28 1.03 53523.314 ---1292121/33 ---ND------13522---ND------95.0 23 ---ND------25.024---ND------25.025---ND------25.0 26 26/29 ---ND------50.027---ND------25.02820/28 1.03 (535)23.314 ---129 29 26/29 ---ND------50.03018/30 ---ND------50.0311.06 35422.962 ---130321.07 81.720.447 ---25.03321/33 ---ND------135 34 ---ND------25.035---ND------25.036---ND------25.0 37 1.02 11027.725 ---53.038---ND------25.039---ND------25.0 40 40/41/71 0.73 33427.490 ---1504140/41/71 0.73 (334)27.490 ---150420.75 18026.987 ---50.04343/73 ---ND------50.04444/47/65 0.78 71526.417 ---1504545/51 0.82 11123.398 ---10046---ND------50.04744/47/65 0.78 (715)26.417 ---150 48 0.78 12226.132 ---50.0 Page 13 of 59Report No.....10439419_1668_209_DFR Page 35 of 81 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses Resultsreportedon a dryweight basis ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SD010-F005 P180724B_09Lab Sample ID 92391608001 Co-elutions RT ng/Kg EMLEMPCConcentration ng/KgIUPACRatio ng/Kg 49 49/69 0.78 57425.830 ---1005050/53 0.85 11422.643 ---1005145/51 0.82 (111)23.398 ---100 52 0.78 82125.310 ---1545350/53 0.85 (114)22.643 ---10054---ND------50.055---ND------50.0560.74 37931.519 ---50.0 57 ---ND------50.058---ND------50.05959/62/75 ---ND------150 60 0.85 17731.737 ---50.06161/70/74/76 0.80 156030.463 ---2006259/62/75 ---ND------150 63 0.81 51.630.111 ---50.0640.78 42627.741 ---50.06544/47/65 0.78 (715)26.417 ---150660.75 104030.815 ---84.067---ND------50.068---ND------50.06949/69 0.78 (574)25.830 ---1007061/70/74/76 0.80 (1560)30.463 ---200 71 40/41/71 0.73 (334)27.490 ---15072---ND------50.07343/73 ---ND------50.0 74 61/70/74/76 0.80 (1560)30.463 ---2007559/62/75 ---ND------1507661/70/74/76 0.80 (1560)30.463 ---200 77 0.82 97.035.443 ---50.078---ND------50.079---ND------50.080---ND------50.081---ND------50.0 82 1.50 10435.024 ---50.083---ND------50.0841.45 14530.681 ---50.0 85 85/116/117 1.53 26434.538 ---1508686/87/97/108/119/125 1.55 43933.750 ---3008786/87/97/108/119/125 1.55 (439)33.750 ---300 88 88/91 1.74 14030.430 ---10089---ND------50.09090/101/113 1.57 60132.609 ---1509188/91 1.74 (140)30.430 ---100921.70 12332.006 ---50.09393/98/100/102 ---ND------20094---ND------50.0951.50 37829.524 ---95.0 96 ---ND------50.0 Page 14 of 59Report No.....10439419_1668_209_DFR Page 36 of 81 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses Resultsreportedon a dryweight basis ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SD010-F005 P180724B_09Lab Sample ID 92391608001 Co-elutions RT ng/Kg EMLEMPCConcentration ng/KgIUPACRatio ng/Kg 97 86/87/97/108/119/125 1.55 (439)33.750 ---3009893/98/100/102 ---ND------200991.47 49533.230 ---50.0 100 93/98/100/102 ---ND------20010190/101/113 1.57 (601)32.609 ---15010293/98/100/102 ---ND------200103---ND------50.0104---ND------50.0 105 1.50 40839.020 ---50.0106---ND------50.0107107/124 ---ND------100 108 86/87/97/108/119/125 1.55 (439)33.750 ---3001091.44 60.837.326 ---50.0110110/115 1.63 76834.689 ---100 111 ---ND------50.0112---ND------50.011390/101/113 1.57 (601)32.609 ---150114---ND------50.0115110/115 1.63 (768)34.689 ---10011685/116/117 1.53 (264)34.538 ---15011785/116/117 1.53 (264)34.538 ---1501181.52 68137.779 ---64.0 119 86/87/97/108/119/125 1.55 (439)33.750 ---300120---ND------50.0121---ND------50.0 122 ---ND------50.0123---ND------50.0124107/124 ---ND------100 125 86/87/97/108/119/125 1.55 (439)33.750 ---300126---ND------50.0127---ND------50.0128128/166 ---ND------100129129/138/163 1.32 49740.982 ---150 130 ---ND------50.0131---ND------50.01321.23 11437.896 ---50.0 133 ---ND------50.0134134/143 ---ND------100135135/151 1.23 14735.611 ---100 136 ---ND------50.0137---ND------50.0138129/138/163 1.32 (497)40.982 ---150139139/140 ---ND------100140139/140 ---ND------1001411.18 69.739.909 ---50.0142---ND------50.0143134/143 ---ND------100 144 ---ND------50.0 Page 15 of 59Report No.....10439419_1668_209_DFR Page 37 of 81 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses Resultsreportedon a dryweight basis ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SD010-F005 P180724B_09Lab Sample ID 92391608001 Co-elutions RT ng/Kg EMLEMPCConcentration ng/KgIUPACRatio ng/Kg 145 ---ND------50.01461.21 66.339.037 ---50.0147147/149 1.26 28736.572 ---100 148 ---ND------50.0149147/149 1.26 (287)36.572 ---100150---ND------50.0151135/151 1.23 (147)35.611 ---100152---ND------50.0 153 153/168 1.20 40839.691 ---100154---ND------50.0155---ND------50.0 156 156/157 ---ND------100157156/157 ---ND------100158---ND------50.0 159 ---ND------50.0160---ND------50.0161---ND------50.0162---ND------50.0163129/138/163 1.32 (497)40.982 ---150164---ND------50.0165---ND------50.0166128/166 ---ND------100 167 ---ND------50.0168153/168 1.20 (408)39.691 ---100169---ND------50.0 170 1.10 11147.929 ---50.0171171/173 ---ND------100172---ND------50.0 173 171/173 ---ND------1001741.12 12643.217 ---50.0175---ND------50.0176---ND------50.01771.10 77.943.653 ---50.0 178 ---ND------50.01791.00 51.438.634 ---50.0180180/193 0.96 26346.621 ---100 181 ---ND------50.0182---ND------50.0183183/185 ---ND------100 184 ---ND------50.0185183/185 ---ND------100186---ND------50.01871.04 18942.323 ---50.0188---ND------50.0189---ND------50.0190---ND------50.0191---ND------50.0 192 ---ND------50.0 Page 16 of 59Report No.....10439419_1668_209_DFR Page 38 of 81 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses Resultsreportedon a dryweight basis ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SD010-F005 P180724B_09Lab Sample ID 92391608001 Co-elutions RT ng/Kg EMLEMPCConcentration ng/KgIUPACRatio ng/Kg 193 180/193 0.96 (263)46.621 ---100194---ND------75.0195---ND------75.0 196 ---ND------75.0197197/200 ---ND------150198198/199 ---ND------150199198/199 ---ND------150200197/200 ---ND------150 201 ---ND------75.0202---ND------75.0203---ND------75.0 204 ---ND------75.0205---ND------75.0206---ND------75.0 207 ---ND------75.0208---ND------75.0209---ND------75.0 Page 17 of 59Report No.....10439419_1668_209_DFR Page 39 of 81 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SD010-F005 P180724B_09 Sample Analysis Results Lab Sample ID 92391608001 Congener Group Concentration ng/Kg Total MonochloroBiphenyls ND TotalDichloroBiphenyls 240 Total TrichloroBiphenyls 1180 Total TetrachloroBiphenyls 6700 TotalPentachloroBiphenyls 4610 TotalHexachloroBiphenyls 1590 TotalHeptachloroBiphenyls 818 Total Octachloro Biphenyls ND TotalNonachloroBiphenyls ND DecachloroBiphenyls ND TotalPCBs 15100 Results reported on a dry weight basis ND = Not Detected Page 18 of 59Report No.....10439419_1668_209_DFR Page 40 of 81 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Client - PACE Charlotte Client's Sample ID Lab Sample ID Filename Injected ByTotal Amount Extracted% Moisture Dry Weight Extracted ICAL ID CCal Filename(s)Method Blank ID BLANK-63507P180724B_01 P180724B02 10.1 g 42.417.5 gCVS P180724B_10 92391608002 ABL-SD011-F005 MatrixDilution Collected Received ExtractedAnalyzed 07/25/2018 07:2007/17/2018 15:00 07/13/2018 09:45 07/11/2018 NASolid Method 1668A Polychlorobiphenyl Sample Analysis Results PCB Isomer RT % Recoveryng's Foundng's AddedIUPACRatio LabeledAnalytes13C-2-MoCB 1 2.79 2.09.563 1.13 5613C-4-MoCB 3 2.79 2.012.427 1.16 5813C-2,2'-DiCB 4 1.56 2.012.739 1.12 5613C-4,4'-DiCB 15 1.49 2.020.021 0.867 4313C-2,2',6-TrCB 19 1.02 2.016.607 1.38 6913C-3,4,4'-TrCB 37 1.16 2.027.742 1.61 8113C-2,2',6,6'-TeCB 54 0.80 2.020.365 1.27 6413C-3,4,4',5-TeCB 81 0.85 2.034.857 1.61 8113C-3,3',4,4'-TeCB 77 0.93 2.035.461 1.49 81 I13C-2,2',4,6,6'-PeCB 104 1.61 2.026.334 1.23 6113C-2,3,3',4,4'-PeCB 105 1.54 2.039.022 1.55 7713C-2,3,4,4',5-PeCB 114 1.45 2.038.334 1.50 7513C-2,3',4,4',5-PeCB 118 1.71 2.037.781 1.47 7413C-2,3',4,4',5'-PeCB 123 1.50 2.037.445 1.51 7613C-3,3',4,4',5-PeCB 126 1.50 2.042.175 1.57 7913C-2,2',4,4',6,6'-HxCB 155 1.25 2.032.493 1.25 6313C-HxCB(156/157)156/157 1.30 4.045.249 2.79 7013C-2,3',4,4',5,5'-HxCB 167 1.28 2.044.042 1.36 6813C-3,3',4,4',5,5'-HxCB 169 1.17 2.048.535 1.50 7513C-2,2',3,4',5,6,6'-HpCB 188 1.13 2.038.250 1.28 6413C-2,3,3',4,4',5,5'-HpCB 189 1.01 2.051.046 1.37 6813C-2,2',3,3',5,5',6,6'-OcCB 202 0.88 2.043.740 1.31 6513C-2,3,3',4,4',5,5',6-OcCB 205 0.88 2.053.094 1.49 7513C-2,2',3,3',4,4',5,5',6-NoCB 206 0.76 2.054.538 1.41 7113C-2,2',3,3',4,5,5',6,6'-NoCB 208 0.79 2.050.507 1.19 6013C--DeCB 209 0.82 2.055.982 1.33 72 I CleanupStandards13C-2,4,4'-TrCB 28 1.17 2.023.332 1.57 7813C-2,3,3',5,5'-PeCB 111 1.65 2.035.428 1.38 6913C-2,2',3,3',5,5',6-HpCB 178 1.19 2.041.387 1.44 72 Recovery Standards13C-2,5-DiCB 9 1.60 2.015.205 NA NA13C-2,2',5,5'-TeCB 52 0.74 2.025.311 NA NA13C-2,2',4,5,5'-PeCB 101 1.58 2.032.745 NA NA13C-2,2',3,4,4',5'-HxCB 138 1.30 2.040.967 NA NA13C-2,2',3,3',4,4',5,5'-OcCB 194 0.91 2.052.728 NA NA Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = NanogramsResultsreportedonadryweightbasis Page 19 of 59Report No.....10439419_1668_209_DFR Page 41 of 81 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses Resultsreportedon a dryweight basis ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SD011-F005 P180724B_10Lab Sample ID 92391608002 Co-elutions RT ng/Kg EMLEMPCConcentration ng/KgIUPACRatio ng/Kg 1 ---ND------25.02---ND------25.03---ND------25.0 4 1.37 15912.751 ---25.05---ND------25.061.67 33.015.720 ---25.07---ND------25.081.50 31616.247 ---25.0 9 ---ND------25.010---ND------25.011---ND------245 12 12/13 ---ND------50.01312/13 ---ND------50.014---ND------25.0 15 1.60 10120.034 ---33.0161.02 16520.010 ---25.0171.13 28919.614 ---25.01818/30 1.00 17919.410 ---50.0190.99 10516.631 ---25.02020/28 1.02 148023.349 ---1292121/33 1.09 52023.601 ---135221.07 36924.053 ---95.0 23 ---ND------25.024---ND------25.0251.00 42.122.695 ---25.0 26 26/29 1.05 12322.410 ---50.0270.99 42.319.770 ---25.02820/28 1.02 (1480)23.349 ---129 29 26/29 1.05 (123)22.410 ---50.03018/30 1.00 (179)19.410 ---50.0311.01 132023.014 ---130321.13 27820.532 ---25.03321/33 1.09 (520)23.601 ---135 34 ---ND------25.035---ND------25.036---ND------25.0 37 1.01 49027.759 ---53.038---ND------25.039---ND------25.0 40 40/41/71 0.74 124027.541 ---1504140/41/71 0.74 (1240)27.541 ---150420.73 73327.004 ---50.04343/73 0.74 74.925.596 ---50.04444/47/65 0.78 244026.434 ---1504545/51 0.84 38723.450 ---100460.82 11823.785 ---50.04744/47/65 0.78 (2440)26.434 ---150 48 0.80 45826.166 ---50.0 Page 20 of 59Report No.....10439419_1668_209_DFR Page 42 of 81 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses Resultsreportedon a dryweight basis ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SD011-F005 P180724B_10Lab Sample ID 92391608002 Co-elutions RT ng/Kg EMLEMPCConcentration ng/KgIUPACRatio ng/Kg 49 49/69 0.76 176025.881 ---1005050/53 0.75 36122.712 ---1005145/51 0.84 (387)23.450 ---100 52 0.77 277025.344 ---1545350/53 0.75 (361)22.712 ---10054---ND------50.055---ND------50.0560.81 158031.638 ---50.0 57 ---ND------50.058---ND------50.05959/62/75 0.71 20726.803 ---150 60 0.77 97931.889 ---50.06161/70/74/76 0.77 605030.531 ---2006259/62/75 0.71 (207)26.803 ---150 63 0.76 17230.162 ---50.0640.78 146027.792 ---50.06544/47/65 0.78 (2440)26.434 ---150660.77 387030.900 ---84.0670.75 63.429.877 ---50.068---ND------50.06949/69 0.76 (1760)25.881 ---1007061/70/74/76 0.77 (6050)30.531 ---200 71 40/41/71 0.74 (1240)27.541 ---15072---ND------50.07343/73 0.74 (74.9)25.596 ---50.0 74 61/70/74/76 0.77 (6050)30.531 ---2007559/62/75 0.71 (207)26.803 ---1507661/70/74/76 0.77 (6050)30.531 ---200 77 0.81 53435.461 ---50.078---ND------50.079---ND------50.080---ND------50.081---ND------50.0 82 1.52 79735.059 ---50.0831.60 37733.197 ---50.0841.64 70930.766 ---50.0 85 85/116/117 1.47 157034.556 ---1508686/87/97/108/119/125 1.52 348033.918 ---3008786/87/97/108/119/125 1.52 (3480)33.918 ---300 88 88/91 1.48 61230.514 ---100891.51 88.231.286 ---50.09090/101/113 1.54 615032.761 ---1509188/91 1.48 (612)30.514 ---100921.60 88432.158 ---50.09393/98/100/102 1.58 23929.944 ---20094---ND------50.0951.56 231029.575 ---95.0 96 ---ND------50.0 Page 21 of 59Report No.....10439419_1668_209_DFR Page 43 of 81 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses Resultsreportedon a dryweight basis ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SD011-F005 P180724B_10Lab Sample ID 92391608002 Co-elutions RT ng/Kg EMLEMPCConcentration ng/KgIUPACRatio ng/Kg 97 86/87/97/108/119/125 1.52 (3480)33.918 ---3009893/98/100/102 1.58 (239)29.944 ---200991.52 288033.298 ---50.0 100 93/98/100/102 1.58 (239)29.944 ---20010190/101/113 1.54 (6150)32.761 ---15010293/98/100/102 1.58 (239)29.944 ---200103---ND------50.0104---ND------50.0 105 1.57 440039.039 ---50.0106---ND------50.0107107/124 1.54 30537.093 ---100 108 86/87/97/108/119/125 1.52 (3480)33.918 ---3001091.56 54537.361 ---50.0110110/115 1.55 529034.723 ---100 111 ---ND------50.0112---ND------50.011390/101/113 1.54 (6150)32.761 ---1501141.44 38838.368 ---50.0115110/115 1.55 (5290)34.723 ---10011685/116/117 1.47 (1570)34.556 ---15011785/116/117 1.47 (1570)34.556 ---1501181.52 810037.814 ---64.0 119 86/87/97/108/119/125 1.52 (3480)33.918 ---300120---ND------50.0121---ND------50.0 122 1.51 16238.167 ---50.01231.61 29737.462 ---50.0124107/124 1.54 (305)37.093 ---100 125 86/87/97/108/119/125 1.52 (3480)33.918 ---300126---ND------50.0127---ND------50.0128128/166 1.22 432042.342 ---100129129/138/163 1.23 4950041.001 ---150 130 1.33 120040.330 ---50.01311.22 21037.428 ---50.01321.19 850037.915 ---50.0 133 1.21 45038.401 ---50.0134134/143 1.21 117036.825 ---100135135/151 1.22 1530035.629 ---100 136 1.24 296033.231 ---50.01371.21 38640.548 ---50.0138129/138/163 1.23 (49500)41.001 ---150139139/140 ---ND------100140139/140 ---ND------1001411.19 1320039.911 ---50.0142---ND------50.0143134/143 1.21 (1170)36.825 ---100 144 1.19 229036.232 ---50.0 Page 22 of 59Report No.....10439419_1668_209_DFR Page 44 of 81 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses Resultsreportedon a dryweight basis ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SD011-F005 P180724B_10Lab Sample ID 92391608002 Co-elutions RT ng/Kg EMLEMPCConcentration ng/KgIUPACRatio ng/Kg 145 ---ND------50.01461.25 615039.055 ---50.0147147/149 1.24 3180036.607 ---100 148 ---ND------50.0149147/149 1.24 (31800)36.607 ---100150---ND------50.0151135/151 1.22 (15300)35.629 ---100152---ND------50.0 153 153/168 1.23 5600039.693 ---1001541.10 61.435.897 ---50.0155---ND------50.0 156 156/157 1.26 383045.232 ---100157156/157 1.26 (3830)45.232 ---1001581.25 397041.387 ---50.0 159 1.28 168043.237 ---50.0160---ND------50.0161---ND------50.0162---ND------50.0163129/138/163 1.23 (49500)41.001 ---1501641.23 262040.682 ---50.01651.15 22338.670 ---50.0166128/166 1.22 (4320)42.342 ---100 167 1.26 130044.075 ---50.0168153/168 1.23 (56000)39.693 ---1001691.64 I ---48.535 165 50.0 170 1.03 4360047.915 ---50.0171171/173 1.01 1290044.326 ---1001721.03 807045.953 ---50.0 173 171/173 1.01 (12900)44.326 ---1001741.04 4610043.220 ---50.01751.06 189042.074 ---50.01761.04 589039.558 ---50.01771.03 2660043.673 ---50.0 178 1.05 967041.420 ---50.01791.03 1850038.653 ---50.0180180/193 1.04 11900046.624 ---100 181 0.92 74.944.092 ---50.0182---ND------50.0183183/185 1.04 3520042.968 ---100 184 ---ND------50.0185183/185 1.04 (35200)42.968 ---100186---ND------50.01871.03 5910042.342 ---50.0188---ND------50.01891.08 157051.068 ---50.01901.02 1120048.468 ---50.01911.08 203046.976 ---50.0 192 ---ND------50.0 Page 23 of 59Report No.....10439419_1668_209_DFR Page 45 of 81 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses Resultsreportedon a dryweight basis ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SD011-F005 P180724B_10Lab Sample ID 92391608002 Co-elutions RT ng/Kg EMLEMPCConcentration ng/KgIUPACRatio ng/Kg 193 180/193 1.04 (119000)46.624 ---1001940.89 3170052.749 ---75.01950.90 1300050.831 ---75.0 196 0.89 1770049.257 ---75.0197197/200 0.89 541045.752 ---150198198/199 0.89 3510048.586 ---150199198/199 0.89 (35100)48.586 ---150200197/200 0.89 (5410)45.752 ---150 201 0.89 462044.712 ---75.02020.88 554043.756 ---75.02030.89 2020049.458 ---75.0 204 ---ND------75.02050.96 150053.116 ---75.02060.79 666054.560 ---75.0 207 0.76 117051.412 ---75.02080.80 143050.529 ---75.02090.64 11356.025 ---75.0 Page 24 of 59Report No.....10439419_1668_209_DFR Page 46 of 81 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SD011-F005 P180724B_10 Sample Analysis Results Lab Sample ID 92391608002 Congener Group Concentration ng/Kg Total MonochloroBiphenyls ND TotalDichloroBiphenyls 610 Total TrichloroBiphenyls 5410 Total TetrachloroBiphenyls 25300 TotalPentachloroBiphenyls 39600 TotalHexachloroBiphenyls 207000 TotalHeptachloroBiphenyls 402000 Total Octachloro Biphenyls 135000 TotalNonachloroBiphenyls 9260 DecachloroBiphenyls 113 TotalPCBs 824000 Results reported on a dry weight basis ND = Not Detected Page 25 of 59Report No.....10439419_1668_209_DFR Page 47 of 81 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Client - PACE Charlotte Client's Sample ID Lab Sample ID Filename Injected ByTotal Amount Extracted% Moisture Dry Weight Extracted ICAL ID CCal Filename(s)Method Blank ID BLANK-63507P180724B_01 P180724B02 10.0 g 31.214.6 gCVS P180724B_08 92391608003 ABL-SD012-F005 MatrixDilution Collected Received ExtractedAnalyzed 07/25/2018 05:2107/17/2018 15:00 07/13/2018 09:45 07/11/2018 NASolid Method 1668A Polychlorobiphenyl Sample Analysis Results PCB Isomer RT % Recoveryng's Foundng's AddedIUPACRatio LabeledAnalytes13C-2-MoCB 1 2.86 2.09.599 1.38 6913C-4-MoCB 3 3.22 2.012.451 1.36 6813C-2,2'-DiCB 4 1.57 2.012.750 1.43 7113C-4,4'-DiCB 15 1.58 2.019.902 1.64 8213C-2,2',6-TrCB 19 0.96 2.016.570 1.59 7913C-3,4,4'-TrCB 37 1.13 2.027.694 1.80 9013C-2,2',6,6'-TeCB 54 0.82 2.020.214 1.43 7213C-3,4,4',5-TeCB 81 0.77 2.034.845 1.79 9013C-3,3',4,4'-TeCB 77 0.74 2.035.415 1.76 8813C-2,2',4,6,6'-PeCB 104 1.68 2.026.319 1.58 7913C-2,3,3',4,4'-PeCB 105 1.78 2.039.026 1.90 9513C-2,3,4,4',5-PeCB 114 1.57 2.038.322 1.86 9313C-2,3',4,4',5-PeCB 118 1.69 2.037.768 1.95 9713C-2,3',4,4',5'-PeCB 123 1.69 2.037.433 1.91 9613C-3,3',4,4',5-PeCB 126 1.60 2.042.195 1.94 9713C-2,2',4,4',6,6'-HxCB 155 1.33 2.032.329 1.55 7713C-HxCB(156/157)156/157 1.29 4.045.236 3.52 8813C-2,3',4,4',5,5'-HxCB 167 1.30 2.044.029 1.67 8413C-3,3',4,4',5,5'-HxCB 169 1.24 2.048.591 1.72 8613C-2,2',3,4',5,6,6'-HpCB 188 1.08 2.038.238 2.11 10513C-2,3,3',4,4',5,5'-HpCB 189 1.01 2.051.095 2.19 11013C-2,2',3,3',5,5',6,6'-OcCB 202 0.89 2.043.743 2.22 11113C-2,3,3',4,4',5,5',6-OcCB 205 0.90 2.053.164 1.86 9313C-2,2',3,3',4,4',5,5',6-NoCB 206 0.73 2.054.587 2.07 10413C-2,2',3,3',4,5,5',6,6'-NoCB 208 0.79 2.050.556 2.12 10613C--DeCB 209 0.73 2.056.031 2.31 115 CleanupStandards13C-2,4,4'-TrCB 28 0.98 2.023.283 1.96 9813C-2,3,3',5,5'-PeCB 111 1.63 2.035.398 1.95 9713C-2,2',3,3',5,5',6-HpCB 178 1.06 2.041.390 2.04 102 Recovery Standards13C-2,5-DiCB 9 1.55 2.015.205 NA NA13C-2,2',5,5'-TeCB 52 0.82 2.025.296 NA NA13C-2,2',4,5,5'-PeCB 101 1.53 2.032.614 NA NA13C-2,2',3,4,4',5'-HxCB 138 1.32 2.040.971 NA NA13C-2,2',3,3',4,4',5,5'-OcCB 194 0.91 2.052.798 NA NA Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = NanogramsResultsreportedonadryweightbasis Page 26 of 59Report No.....10439419_1668_209_DFR Page 48 of 81 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses Resultsreportedon a dryweight basis ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SD012-F005 P180724B_08Lab Sample ID 92391608003 Co-elutions RT ng/Kg EMLEMPCConcentration ng/KgIUPACRatio ng/Kg 1 ---ND------25.02---ND------25.03---ND------25.0 4 ---ND------25.05---ND------25.06---ND------25.07---ND------25.08---ND------25.0 9 ---ND------25.010---ND------25.011---ND------245 12 12/13 ---ND------50.01312/13 ---ND------50.014---ND------25.0 15 ---ND------33.016---ND------25.017---ND------25.01818/30 ---ND------50.019---ND------25.02020/28 ---ND------1292121/33 ---ND------13522---ND------95.0 23 ---ND------25.024---ND------25.025---ND------25.0 26 26/29 ---ND------50.027---ND------25.02820/28 ---ND------129 29 26/29 ---ND------50.03018/30 ---ND------50.031---ND------13032---ND------25.03321/33 ---ND------135 34 ---ND------25.035---ND------25.036---ND------25.0 37 ---ND------53.038---ND------25.039---ND------25.0 40 40/41/71 ---ND------1504140/41/71 ---ND------15042---ND------50.04343/73 ---ND------50.04444/47/65 ---ND------1504545/51 ---ND------10046---ND------50.04744/47/65 ---ND------150 48 ---ND------50.0 Page 27 of 59Report No.....10439419_1668_209_DFR Page 49 of 81 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses Resultsreportedon a dryweight basis ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SD012-F005 P180724B_08Lab Sample ID 92391608003 Co-elutions RT ng/Kg EMLEMPCConcentration ng/KgIUPACRatio ng/Kg 49 49/69 ---ND------1005050/53 ---ND------1005145/51 ---ND------100 52 ---ND------1545350/53 ---ND------10054---ND------50.055---ND------50.056---ND------50.0 57 ---ND------50.058---ND------50.05959/62/75 ---ND------150 60 ---ND------50.06161/70/74/76 ---ND------2006259/62/75 ---ND------150 63 ---ND------50.064---ND------50.06544/47/65 ---ND------15066---ND------84.067---ND------50.068---ND------50.06949/69 ---ND------1007061/70/74/76 ---ND------200 71 40/41/71 ---ND------15072---ND------50.07343/73 ---ND------50.0 74 61/70/74/76 ---ND------2007559/62/75 ---ND------1507661/70/74/76 ---ND------200 77 ---ND------50.078---ND------50.079---ND------50.080---ND------50.081---ND------50.0 82 ---ND------50.083---ND------50.084---ND------50.0 85 85/116/117 ---ND------1508686/87/97/108/119/125 ---ND------3008786/87/97/108/119/125 ---ND------300 88 88/91 ---ND------10089---ND------50.09090/101/113 ---ND------1509188/91 ---ND------10092---ND------50.09393/98/100/102 ---ND------20094---ND------50.095---ND------95.0 96 ---ND------50.0 Page 28 of 59Report No.....10439419_1668_209_DFR Page 50 of 81 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses Resultsreportedon a dryweight basis ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SD012-F005 P180724B_08Lab Sample ID 92391608003 Co-elutions RT ng/Kg EMLEMPCConcentration ng/KgIUPACRatio ng/Kg 97 86/87/97/108/119/125 ---ND------3009893/98/100/102 ---ND------20099---ND------50.0 100 93/98/100/102 ---ND------20010190/101/113 ---ND------15010293/98/100/102 ---ND------200103---ND------50.0104---ND------50.0 105 ---ND------50.0106---ND------50.0107107/124 ---ND------100 108 86/87/97/108/119/125 ---ND------300109---ND------50.0110110/115 ---ND------100 111 ---ND------50.0112---ND------50.011390/101/113 ---ND------150114---ND------50.0115110/115 ---ND------10011685/116/117 ---ND------15011785/116/117 ---ND------150118---ND------64.0 119 86/87/97/108/119/125 ---ND------300120---ND------50.0121---ND------50.0 122 ---ND------50.0123---ND------50.0124107/124 ---ND------100 125 86/87/97/108/119/125 ---ND------300126---ND------50.0127---ND------50.0128128/166 ---ND------100129129/138/163 1.27 21440.971 ---150 130 ---ND------50.0131---ND------50.0132---ND------50.0 133 ---ND------50.0134134/143 ---ND------100135135/151 ---ND------100 136 ---ND------50.0137---ND------50.0138129/138/163 1.27 (214)40.971 ---150139139/140 ---ND------100140139/140 ---ND------100141---ND------50.0142---ND------50.0143134/143 ---ND------100 144 ---ND------50.0 Page 29 of 59Report No.....10439419_1668_209_DFR Page 51 of 81 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses Resultsreportedon a dryweight basis ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SD012-F005 P180724B_08Lab Sample ID 92391608003 Co-elutions RT ng/Kg EMLEMPCConcentration ng/KgIUPACRatio ng/Kg 145 ---ND------50.0146---ND------50.0147147/149 ---ND------100 148 ---ND------50.0149147/149 ---ND------100150---ND------50.0151135/151 ---ND------100152---ND------50.0 153 153/168 1.22 18739.697 ---100154---ND------50.0155---ND------50.0 156 156/157 ---ND------100157156/157 ---ND------100158---ND------50.0 159 ---ND------50.0160---ND------50.0161---ND------50.0162---ND------50.0163129/138/163 1.27 (214)40.971 ---150164---ND------50.0165---ND------50.0166128/166 ---ND------100 167 ---ND------50.0168153/168 1.22 (187)39.697 ---100169---ND------50.0 170 ---ND------50.0171171/173 ---ND------100172---ND------50.0 173 171/173 ---ND------100174---ND------50.0175---ND------50.0176---ND------50.0177---ND------50.0 178 ---ND------50.0179---ND------50.0180180/193 1.05 11746.628 ---100 181 ---ND------50.0182---ND------50.0183183/185 ---ND------100 184 ---ND------50.0185183/185 ---ND------100186---ND------50.01870.90 60.942.329 ---50.0188---ND------50.0189---ND------50.0190---ND------50.0191---ND------50.0 192 ---ND------50.0 Page 30 of 59Report No.....10439419_1668_209_DFR Page 52 of 81 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses Resultsreportedon a dryweight basis ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SD012-F005 P180724B_08Lab Sample ID 92391608003 Co-elutions RT ng/Kg EMLEMPCConcentration ng/KgIUPACRatio ng/Kg 193 180/193 1.05 (117)46.628 ---100194---ND------75.0195---ND------75.0 196 ---ND------75.0197197/200 ---ND------150198198/199 ---ND------150199198/199 ---ND------150200197/200 ---ND------150 201 ---ND------75.0202---ND------75.0203---ND------75.0 204 ---ND------75.0205---ND------75.0206---ND------75.0 207 ---ND------75.0208---ND------75.0209---ND------75.0 Page 31 of 59Report No.....10439419_1668_209_DFR Page 53 of 81 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SD012-F005 P180724B_08 Sample Analysis Results Lab Sample ID 92391608003 Congener Group Concentration ng/Kg Total MonochloroBiphenyls ND TotalDichloroBiphenyls ND Total TrichloroBiphenyls ND Total TetrachloroBiphenyls ND TotalPentachloroBiphenyls ND TotalHexachloroBiphenyls 402 TotalHeptachloroBiphenyls 178 Total Octachloro Biphenyls ND TotalNonachloroBiphenyls ND DecachloroBiphenyls ND TotalPCBs 580 Results reported on a dry weight basis ND = Not Detected Page 32 of 59Report No.....10439419_1668_209_DFR Page 54 of 81 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Client - PACE Charlotte Client's Sample ID Lab Sample ID Filename Injected ByTotal Amount Extracted% Moisture Dry Weight Extracted ICAL ID CCal Filename(s)Method Blank ID BLANK-63512P180721B_01 P180721B02 NA NA945 mLBAL P180721B_07 92391608004 ABL-EB001-F005 MatrixDilution Collected Received ExtractedAnalyzed 07/21/2018 23:5307/17/2018 13:15 07/13/2018 09:45 07/11/2018 NAWater Method 1668A Polychlorobiphenyl Sample Analysis Results PCB Isomer RT % Recoveryng's Foundng's AddedIUPACRatio LabeledAnalytes13C-2-MoCB 1 2.72 2.09.599 0.861 4313C-4-MoCB 3 2.79 2.012.427 1.01 5013C-2,2'-DiCB 4 1.61 2.012.727 0.915 4613C-4,4'-DiCB 15 1.66 2.019.879 1.30 6513C-2,2',6-TrCB 19 0.96 2.016.559 0.991 5013C-3,4,4'-TrCB 37 1.09 2.027.694 1.81 9013C-2,2',6,6'-TeCB 54 0.79 2.020.198 1.10 5513C-3,4,4',5-TeCB 81 0.88 2.034.826 1.83 9113C-3,3',4,4'-TeCB 77 0.76 2.035.429 1.77 8913C-2,2',4,6,6'-PeCB 104 1.49 2.026.302 1.12 5613C-2,3,3',4,4'-PeCB 105 1.62 2.039.006 1.84 9213C-2,3,4,4',5-PeCB 114 1.58 2.038.319 1.79 9013C-2,3',4,4',5-PeCB 118 1.62 2.037.765 1.81 9013C-2,3',4,4',5'-PeCB 123 1.59 2.037.447 1.77 8913C-3,3',4,4',5-PeCB 126 1.58 2.042.192 1.99 9913C-2,2',4,4',6,6'-HxCB 155 1.29 2.032.327 1.22 6113C-HxCB(156/157)156/157 1.25 4.045.233 3.46 8713C-2,3',4,4',5,5'-HxCB 167 1.29 2.044.025 1.70 8513C-3,3',4,4',5,5'-HxCB 169 1.30 2.048.536 1.86 9313C-2,2',3,4',5,6,6'-HpCB 188 1.07 2.038.235 1.46 7313C-2,3,3',4,4',5,5'-HpCB 189 1.11 2.051.025 1.92 9613C-2,2',3,3',5,5',6,6'-OcCB 202 0.91 2.043.740 1.55 7713C-2,3,3',4,4',5,5',6-OcCB 205 0.90 2.053.095 1.74 8713C-2,2',3,3',4,4',5,5',6-NoCB 206 0.79 2.054.539 1.53 7613C-2,2',3,3',4,5,5',6,6'-NoCB 208 0.79 2.050.486 1.52 7613C--DeCB 209 0.72 2.055.983 1.52 76 CleanupStandards13C-2,4,4'-TrCB 28 1.05 2.023.284 1.66 8313C-2,3,3',5,5'-PeCB 111 1.60 2.035.379 1.68 8413C-2,2',3,3',5,5',6-HpCB 178 1.05 2.041.371 1.56 78 Recovery Standards13C-2,5-DiCB 9 1.59 2.015.182 NA NA13C-2,2',5,5'-TeCB 52 0.82 2.025.279 NA NA13C-2,2',4,5,5'-PeCB 101 1.55 2.032.579 NA NA13C-2,2',3,4,4',5'-HxCB 138 1.24 2.040.968 NA NA13C-2,2',3,3',4,4',5,5'-OcCB 194 1.02 2.052.707 NA NA Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Page 33 of 59Report No.....10439419_1668_209_DFR Page 55 of 81 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-EB001-F005 P180721B_07Lab Sample ID 92391608004 Co-elutions RT ng/L EMLEMPCConcentration ng/LIUPACRatio ng/L 1 ---ND------0.2502---ND------0.2503---ND------0.250 4 ---ND------0.2505---ND------0.2506---ND------0.2507---ND------0.2508---ND------0.250 9 ---ND------0.25010---ND------0.25011---ND------2.45 12 12/13 ---ND------0.5001312/13 ---ND------0.50014---ND------0.250 15 ---ND------0.33016---ND------0.25017---ND------0.2501818/30 ---ND------0.50019---ND------0.2502020/28 ---ND------1.292121/33 ---ND------1.3522---ND------0.950 23 ---ND------0.25024---ND------0.25025---ND------0.250 26 26/29 ---ND------0.50027---ND------0.2502820/28 ---ND------1.29 29 26/29 ---ND------0.5003018/30 ---ND------0.50031---ND------1.3032---ND------0.2503321/33 ---ND------1.35 34 ---ND------0.25035---ND------0.25036---ND------0.250 37 ---ND------0.53038---ND------0.25039---ND------0.250 40 40/41/71 ---ND------1.504140/41/71 ---ND------1.5042---ND------0.5004343/73 ---ND------0.5004444/47/65 ---ND------1.504545/51 ---ND------1.0046---ND------0.5004744/47/65 ---ND------1.50 48 ---ND------0.500 Page 34 of 59Report No.....10439419_1668_209_DFR Page 56 of 81 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-EB001-F005 P180721B_07Lab Sample ID 92391608004 Co-elutions RT ng/L EMLEMPCConcentration ng/LIUPACRatio ng/L 49 49/69 ---ND------1.005050/53 ---ND------1.005145/51 ---ND------1.00 52 ---ND------1.545350/53 ---ND------1.0054---ND------0.50055---ND------0.50056---ND------0.500 57 ---ND------0.50058---ND------0.5005959/62/75 ---ND------1.50 60 ---ND------0.5006161/70/74/76 ---ND------2.006259/62/75 ---ND------1.50 63 ---ND------0.50064---ND------0.5006544/47/65 ---ND------1.5066---ND------0.84067---ND------0.50068---ND------0.5006949/69 ---ND------1.007061/70/74/76 ---ND------2.00 71 40/41/71 ---ND------1.5072---ND------0.5007343/73 ---ND------0.500 74 61/70/74/76 ---ND------2.007559/62/75 ---ND------1.507661/70/74/76 ---ND------2.00 77 ---ND------0.50078---ND------0.50079---ND------0.50080---ND------0.50081---ND------0.500 82 ---ND------0.50083---ND------0.50084---ND------0.500 85 85/116/117 ---ND------1.508686/87/97/108/119/125 ---ND------3.008786/87/97/108/119/125 ---ND------3.00 88 88/91 ---ND------1.0089---ND------0.5009090/101/113 ---ND------1.509188/91 ---ND------1.0092---ND------0.5009393/98/100/102 ---ND------2.0094---ND------0.50095---ND------0.950 96 ---ND------0.500 Page 35 of 59Report No.....10439419_1668_209_DFR Page 57 of 81 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-EB001-F005 P180721B_07Lab Sample ID 92391608004 Co-elutions RT ng/L EMLEMPCConcentration ng/LIUPACRatio ng/L 97 86/87/97/108/119/125 ---ND------3.009893/98/100/102 ---ND------2.0099---ND------0.500 100 93/98/100/102 ---ND------2.0010190/101/113 ---ND------1.5010293/98/100/102 ---ND------2.00103---ND------0.500104---ND------0.500 105 ---ND------0.500106---ND------0.500107107/124 ---ND------1.00 108 86/87/97/108/119/125 ---ND------3.00109---ND------0.500110110/115 ---ND------1.00 111 ---ND------0.500112---ND------0.50011390/101/113 ---ND------1.50114---ND------0.500115110/115 ---ND------1.0011685/116/117 ---ND------1.5011785/116/117 ---ND------1.50118---ND------0.640 119 86/87/97/108/119/125 ---ND------3.00120---ND------0.500121---ND------0.500 122 ---ND------0.500123---ND------0.500124107/124 ---ND------1.00 125 86/87/97/108/119/125 ---ND------3.00126---ND------0.500127---ND------0.500128128/166 ---ND------1.00129129/138/163 ---ND------1.50 130 ---ND------0.500131---ND------0.500132---ND------0.500 133 ---ND------0.500134134/143 ---ND------1.00135135/151 ---ND------1.00 136 ---ND------0.500137---ND------0.500138129/138/163 ---ND------1.50139139/140 ---ND------1.00140139/140 ---ND------1.00141---ND------0.500142---ND------0.500143134/143 ---ND------1.00 144 ---ND------0.500 Page 36 of 59Report No.....10439419_1668_209_DFR Page 58 of 81 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-EB001-F005 P180721B_07Lab Sample ID 92391608004 Co-elutions RT ng/L EMLEMPCConcentration ng/LIUPACRatio ng/L 145 ---ND------0.500146---ND------0.500147147/149 ---ND------1.00 148 ---ND------0.500149147/149 ---ND------1.00150---ND------0.500151135/151 ---ND------1.00152---ND------0.500 153 153/168 ---ND------1.00154---ND------0.500155---ND------0.500 156 156/157 ---ND------1.00157156/157 ---ND------1.00158---ND------0.500 159 ---ND------0.500160---ND------0.500161---ND------0.500162---ND------0.500163129/138/163 ---ND------1.50164---ND------0.500165---ND------0.500166128/166 ---ND------1.00 167 ---ND------0.500168153/168 ---ND------1.00169---ND------0.500 170 ---ND------0.500171171/173 ---ND------1.00172---ND------0.500 173 171/173 ---ND------1.00174---ND------0.500175---ND------0.500176---ND------0.500177---ND------0.500 178 ---ND------0.500179---ND------0.500180180/193 ---ND------1.00 181 ---ND------0.500182---ND------0.500183183/185 ---ND------1.00 184 ---ND------0.500185183/185 ---ND------1.00186---ND------0.500187---ND------0.500188---ND------0.500189---ND------0.500190---ND------0.500191---ND------0.500 192 ---ND------0.500 Page 37 of 59Report No.....10439419_1668_209_DFR Page 59 of 81 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-EB001-F005 P180721B_07Lab Sample ID 92391608004 Co-elutions RT ng/L EMLEMPCConcentration ng/LIUPACRatio ng/L 193 180/193 ---ND------1.00194---ND------0.750195---ND------0.750 196 ---ND------0.750197197/200 ---ND------1.50198198/199 ---ND------1.50199198/199 ---ND------1.50200197/200 ---ND------1.50 201 ---ND------0.750202---ND------0.750203---ND------0.750 204 ---ND------0.750205---ND------0.750206---ND------0.750 207 ---ND------0.750208---ND------0.750209---ND------0.750 Page 38 of 59Report No.....10439419_1668_209_DFR Page 60 of 81 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-EB001-F005 P180721B_07 Sample Analysis Results Lab Sample ID 92391608004 Congener Group Concentration ng/L Total MonochloroBiphenyls ND TotalDichloroBiphenyls ND Total TrichloroBiphenyls ND Total TetrachloroBiphenyls ND TotalPentachloroBiphenyls ND TotalHexachloroBiphenyls ND TotalHeptachloroBiphenyls ND Total Octachloro Biphenyls ND TotalNonachloroBiphenyls ND DecachloroBiphenyls ND Total PCBs ND ND = Not Detected Page 39 of 59Report No.....10439419_1668_209_DFR Page 61 of 81 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Method 1668A Polychlorobiphenyl Lab Sample ID Injected ByFilename Total Amount Extracted ICAL ID CCal Filename(s) BLANK-63512 P180721B_06BAL1040 mL P180721B02 P180721B_01 MatrixExtracted Analyzed Water (QC Matrix)07/17/2018 13:15 07/21/2018 22:54 Blank Analysis Results Dilution NA PCB Isomer RT % Recoveryng's Foundng's AddedIUPACRatio Labeled Analytes13C-2-MoCB 1 2.94 2.09.599 1.30 6513C-4-MoCB 3 2.84 2.012.439 1.42 7113C-2,2'-DiCB 4 1.54 2.012.738 1.28 6413C-4,4'-DiCB 15 1.52 2.019.890 1.48 7413C-2,2',6-TrCB 19 0.96 2.016.559 1.91 9613C-3,4,4'-TrCB 37 1.17 2.027.710 1.92 9613C-2,2',6,6'-TeCB 54 0.89 2.020.197 1.45 73 13C-3,4,4',5-TeCB 81 0.84 2.034.825 1.81 9013C-3,3',4,4'-TeCB 77 0.85 2.035.429 1.79 9013C-2,2',4,6,6'-PeCB 104 1.52 2.026.318 1.28 6413C-2,3,3',4,4'-PeCB 105 1.60 2.039.006 1.88 9413C-2,3,4,4',5-PeCB 114 1.64 2.038.335 1.78 8913C-2,3',4,4',5-PeCB 118 1.51 2.037.782 1.85 9213C-2,3',4,4',5'-PeCB 123 1.49 2.037.446 1.85 9313C-3,3',4,4',5-PeCB 126 1.59 2.042.192 1.97 9913C-2,2',4,4',6,6'-HxCB 155 1.27 2.032.327 1.27 6413C-HxCB (156/157)156/157 1.31 4.045.250 3.34 8413C-2,3',4,4',5,5'-HxCB 167 1.28 2.044.042 1.68 8413C-3,3',4,4',5,5'-HxCB 169 1.29 2.048.536 1.86 9313C-2,2',3,4',5,6,6'-HpCB 188 1.02 2.038.251 1.47 7413C-2,3,3',4,4',5,5'-HpCB 189 1.07 2.051.047 1.80 9013C-2,2',3,3',5,5',6,6'-OcCB 202 0.95 2.043.740 1.55 7713C-2,3,3',4,4',5,5',6-OcCB 205 0.89 2.053.116 1.74 8713C-2,2',3,3',4,4',5,5',6-NoCB 206 0.76 2.054.539 1.60 8013C-2,2',3,3',4,5,5',6,6'-NoCB 208 0.84 2.050.508 1.56 7813C--DeCB 209 0.63 2.055.983 1.62 81 Cleanup Standards13C-2,4,4'-TrCB 28 1.15 2.023.283 2.23 11113C-2,3,3',5,5'-PeCB 111 1.61 2.035.396 1.82 9113C-2,2',3,3',5,5',6-HpCB 178 1.05 2.041.387 1.75 87 Recovery Standards13C-2,5-DiCB 9 1.60 2.015.193 NA NA13C-2,2',5,5'-TeCB 52 0.75 2.025.295 NA NA13C-2,2',4,5,5'-PeCB 101 1.62 2.032.595 NA NA13C-2,2',3,4,4',5'-HxCB 138 1.25 2.040.968 NA NA13C-2,2',3,3',4,4',5,5'-OcCB 194 0.94 2.052.728 NA NA Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Page 40 of 59Report No.....10439419_1668_209_DFR Page 62 of 81 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits ng/L = Nanograms per liter ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference Method 1668A Polychlorobiphenyl Lab Sample ID Filename BLANK-63512 P180721B_06 Blank Analysis Results Co-elutions RT ng/L EMLEMPCConcentration ng/LIUPACRatio ng/L 1 ---ND------0.2412---ND------0.2413---ND------0.2414---ND------0.2415---ND------0.2416---ND------0.2417---ND------0.2418---ND------0.2419---ND------0.24110---ND------0.24111---ND------2.371212/13 ---ND------0.4831312/13 ---ND------0.48314---ND------0.24115---ND------0.24116---ND------0.24117---ND------0.2411818/30 ---ND------0.483 19 ---ND------0.2412020/28 ---ND------1.252121/33 ---ND------1.3022---ND------0.91823---ND------0.24124---ND------0.24125---ND------0.2412626/29 ---ND------0.48327---ND------0.2412820/28 ---ND------1.252926/29 ---ND------0.4833018/30 ---ND------0.48331---ND------1.2632---ND------0.2413321/33 ---ND------1.3034---ND------0.24135---ND------0.24136---ND------0.24137---ND------0.51238---ND------0.24139---ND------0.2414040/41/71 ---ND------1.454140/41/71 ---ND------1.4542---ND------0.4834343/73 ---ND------0.483 44 44/47/65 ---ND------1.454545/51 ---ND------0.966 Page 41 of 59Report No.....10439419_1668_209_DFR Page 63 of 81 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits ng/L = Nanograms per liter ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference Method 1668A Polychlorobiphenyl Lab Sample ID Filename BLANK-63512 P180721B_06 Blank Analysis Results Co-elutions RT ng/L EMLEMPCConcentration ng/LIUPACRatio ng/L 46 ---ND------0.4834744/47/65 ---ND------1.4548---ND------0.4834949/69 ---ND------0.9665050/53 ---ND------0.9665145/51 ---ND------0.96652---ND------1.495350/53 ---ND------0.96654---ND------0.48355---ND------0.48356---ND------0.48357---ND------0.48358---ND------0.4835959/62/75 ---ND------1.4560---ND------0.4836161/70/74/76 ---ND------1.936259/62/75 ---ND------1.4563---ND------0.483 64 ---ND------0.4836544/47/65 ---ND------1.4566---ND------0.81167---ND------0.48368---ND------0.4836949/69 ---ND------0.9667061/70/74/76 ---ND------1.937140/41/71 ---ND------1.4572---ND------0.4837343/73 ---ND------0.4837461/70/74/76 ---ND------1.937559/62/75 ---ND------1.457661/70/74/76 ---ND------1.9377---ND------0.48378---ND------0.48379---ND------0.48380---ND------0.48381---ND------0.48382---ND------0.48383---ND------0.48384---ND------0.4838585/116/117 ---ND------1.458686/87/97/108/119/125 ---ND------2.908786/87/97/108/119/125 ---ND------2.908888/91 ---ND------0.966 89 ---ND------0.4839090/101/113 ---ND------1.45 Page 42 of 59Report No.....10439419_1668_209_DFR Page 64 of 81 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits ng/L = Nanograms per liter ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference Method 1668A Polychlorobiphenyl Lab Sample ID Filename BLANK-63512 P180721B_06 Blank Analysis Results Co-elutions RT ng/L EMLEMPCConcentration ng/LIUPACRatio ng/L 91 88/91 ---ND------0.96692---ND------0.4839393/98/100/102 ---ND------1.9394---ND------0.48395---ND------0.91896---ND------0.4839786/87/97/108/119/125 ---ND------2.909893/98/100/102 ---ND------1.9399---ND------0.48310093/98/100/102 ---ND------1.9310190/101/113 ---ND------1.4510293/98/100/102 ---ND------1.93103---ND------0.483104---ND------0.483105---ND------0.483106---ND------0.483107107/124 ---ND------0.96610886/87/97/108/119/125 ---ND------2.90 109 ---ND------0.483110110/115 ---ND------0.966111---ND------0.483112---ND------0.48311390/101/113 ---ND------1.45114---ND------0.483115110/115 ---ND------0.96611685/116/117 ---ND------1.4511785/116/117 ---ND------1.45118---ND------0.61811986/87/97/108/119/125 ---ND------2.90120---ND------0.483121---ND------0.483122---ND------0.483123---ND------0.483124107/124 ---ND------0.96612586/87/97/108/119/125 ---ND------2.90126---ND------0.483127---ND------0.483128128/166 ---ND------0.966129129/138/163 ---ND------1.45130---ND------0.483131---ND------0.483132---ND------0.483133---ND------0.483 134 134/143 ---ND------0.966135135/151 ---ND------0.966 Page 43 of 59Report No.....10439419_1668_209_DFR Page 65 of 81 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits ng/L = Nanograms per liter ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference Method 1668A Polychlorobiphenyl Lab Sample ID Filename BLANK-63512 P180721B_06 Blank Analysis Results Co-elutions RT ng/L EMLEMPCConcentration ng/LIUPACRatio ng/L 136 ---ND------0.483137---ND------0.483138129/138/163 ---ND------1.45139139/140 ---ND------0.966140139/140 ---ND------0.966141---ND------0.483142---ND------0.483143134/143 ---ND------0.966144---ND------0.483145---ND------0.483146---ND------0.483147147/149 ---ND------0.966148---ND------0.483149147/149 ---ND------0.966150---ND------0.483151135/151 ---ND------0.966152---ND------0.483153153/168 ---ND------0.966 154 ---ND------0.483155---ND------0.483156156/157 ---ND------0.966157156/157 ---ND------0.966158---ND------0.483159---ND------0.483160---ND------0.483161---ND------0.483162---ND------0.483163129/138/163 ---ND------1.45164---ND------0.483165---ND------0.483166128/166 ---ND------0.966167---ND------0.483168153/168 ---ND------0.966169---ND------0.483170---ND------0.483171171/173 ---ND------0.966172---ND------0.483173171/173 ---ND------0.966174---ND------0.483175---ND------0.483176---ND------0.483177---ND------0.483178---ND------0.483 179 ---ND------0.483180180/193 ---ND------0.966 Page 44 of 59Report No.....10439419_1668_209_DFR Page 66 of 81 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits ng/L = Nanograms per liter ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference Method 1668A Polychlorobiphenyl Lab Sample ID Filename BLANK-63512 P180721B_06 Blank Analysis Results Co-elutions RT ng/L EMLEMPCConcentration ng/LIUPACRatio ng/L 181 ---ND------0.483182---ND------0.483183183/185 ---ND------0.966184---ND------0.483185183/185 ---ND------0.966186---ND------0.483187---ND------0.483188---ND------0.483189---ND------0.483190---ND------0.483191---ND------0.483192---ND------0.483193180/193 ---ND------0.966194---ND------0.724195---ND------0.724196---ND------0.724197197/200 ---ND------1.45198198/199 ---ND------1.45 199 198/199 ---ND------1.45200197/200 ---ND------1.45201---ND------0.724202---ND------0.724203---ND------0.724204---ND------0.724205---ND------0.724206---ND------0.724207---ND------0.724208---ND------0.724209---ND------0.724 Page 45 of 59Report No.....10439419_1668_209_DFR Page 67 of 81 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Method 1668A Polychlorobiphenyl Client Sample ID Filename CBLKSY P180721B_06 Blank Analysis Results Lab Sample ID BLANK-63512 Congener Group Concentration ng/L Total MonochloroBiphenyls ND TotalDichloroBiphenyls ND Total TrichloroBiphenyls ND Total TetrachloroBiphenyls ND TotalPentachloroBiphenyls ND TotalHexachloroBiphenyls ND TotalHeptachloroBiphenyls ND Total Octachloro Biphenyls ND TotalNonachloroBiphenyls ND DecachloroBiphenyls ND Total PCBs ND ND = Not Detected Page 46 of 59Report No.....10439419_1668_209_DFR Page 68 of 81 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Method 1668A Polychlorobiphenyl Lab Sample ID Injected ByFilename Total Amount Extracted ICAL ID CCal Filename(s) BLANK-63507 P180723B_07BAL10.7 g P180723B02 P180723B_01 MatrixExtracted Analyzed Soil/Solid (QC Matrix)07/17/2018 15:00 07/23/2018 23:24 Blank Analysis Results Dilution NA PCB Isomer RT % Recoveryng's Foundng's AddedIUPACRatio Labeled Analytes13C-2-MoCB 1 2.72 2.09.576 1.23 6213C-4-MoCB 3 3.20 2.012.427 1.14 5713C-2,2'-DiCB 4 1.33 2.012.739 1.13 5613C-4,4'-DiCB 15 1.58 2.019.903 1.39 6913C-2,2',6-TrCB 19 1.07 2.016.608 1.40 7013C-3,4,4'-TrCB 37 1.20 2.027.711 1.81 9013C-2,2',6,6'-TeCB 54 0.74 2.020.215 1.36 68 13C-3,4,4',5-TeCB 81 0.73 2.034.827 1.54 7713C-3,3',4,4'-TeCB 77 0.76 2.035.464 1.54 7713C-2,2',4,6,6'-PeCB 104 1.63 2.026.302 1.35 6813C-2,3,3',4,4'-PeCB 105 1.51 2.039.008 1.64 8213C-2,3,4,4',5-PeCB 114 1.68 2.038.320 1.62 8113C-2,3',4,4',5-PeCB 118 1.68 2.037.784 1.54 7713C-2,3',4,4',5'-PeCB 123 1.51 2.037.432 1.63 8113C-3,3',4,4',5-PeCB 126 1.54 2.042.178 1.88 9413C-2,2',4,4',6,6'-HxCB 155 1.16 2.032.328 1.28 6413C-HxCB (156/157)156/157 1.23 4.045.218 2.86 7113C-2,3',4,4',5,5'-HxCB 167 1.38 2.044.044 1.47 7413C-3,3',4,4',5,5'-HxCB 169 1.25 2.048.556 1.60 8013C-2,2',3,4',5,6,6'-HpCB 188 1.05 2.038.253 1.36 6813C-2,3,3',4,4',5,5'-HpCB 189 1.00 2.051.050 1.50 7513C-2,2',3,3',5,5',6,6'-OcCB 202 0.89 2.043.726 1.48 7413C-2,3,3',4,4',5,5',6-OcCB 205 0.93 2.053.098 1.45 7313C-2,2',3,3',4,4',5,5',6-NoCB 206 0.74 2.054.520 1.62 8113C-2,2',3,3',4,5,5',6,6'-NoCB 208 0.81 2.050.489 1.56 7813C--DeCB 209 0.73 2.055.986 1.57 78 Cleanup Standards13C-2,4,4'-TrCB 28 1.01 2.023.301 1.59 8013C-2,3,3',5,5'-PeCB 111 1.68 2.035.397 1.49 7513C-2,2',3,3',5,5',6-HpCB 178 1.09 2.041.389 1.65 82 Recovery Standards13C-2,5-DiCB 9 1.58 2.015.229 NA NA13C-2,2',5,5'-TeCB 52 0.84 2.025.280 NA NA13C-2,2',4,5,5'-PeCB 101 1.58 2.032.597 NA NA13C-2,2',3,4,4',5'-HxCB 138 1.31 2.040.970 NA NA13C-2,2',3,3',4,4',5,5'-OcCB 194 0.87 2.052.731 NA NA Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = NanogramsResultsreportedonatotalweightbasis Page 47 of 59Report No.....10439419_1668_209_DFR Page 69 of 81 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits ng/L = Nanograms per liter Resultsreported ona totalweight basis ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference Method 1668A Polychlorobiphenyl Lab Sample ID Filename BLANK-63507 P180723B_07 Blank Analysis Results Co-elutions RT ng/Kg EMLEMPCConcentration ng/KgIUPACRatio ng/Kg 1 ---ND------23.42---ND------23.43---ND------23.44---ND------23.45---ND------23.46---ND------23.47---ND------23.48---ND------23.49---ND------23.410---ND------23.411---ND------2291212/13 ---ND------46.71312/13 ---ND------46.714---ND------23.415---ND------23.416---ND------23.417---ND------23.41818/30 ---ND------46.7 19 ---ND------23.42020/28 ---ND------1212121/33 ---ND------12622---ND------88.823---ND------23.424---ND------23.425---ND------23.42626/29 ---ND------46.727---ND------23.42820/28 ---ND------1212926/29 ---ND------46.73018/30 ---ND------46.731---ND------12132---ND------23.43321/33 ---ND------12634---ND------23.435---ND------23.436---ND------23.437---ND------49.538---ND------23.439---ND------23.44040/41/71 ---ND------1404140/41/71 ---ND------14042---ND------46.74343/73 ---ND------46.7 44 44/47/65 ---ND------1404545/51 ---ND------93.5 Page 48 of 59Report No.....10439419_1668_209_DFR Page 70 of 81 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits ng/L = Nanograms per liter Resultsreported ona totalweight basis ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference Method 1668A Polychlorobiphenyl Lab Sample ID Filename BLANK-63507 P180723B_07 Blank Analysis Results Co-elutions RT ng/Kg EMLEMPCConcentration ng/KgIUPACRatio ng/Kg 46 ---ND------46.74744/47/65 ---ND------14048---ND------46.74949/69 ---ND------93.55050/53 ---ND------93.55145/51 ---ND------93.552---ND------1445350/53 ---ND------93.554---ND------46.755---ND------46.756---ND------46.757---ND------46.758---ND------46.75959/62/75 ---ND------14060---ND------46.76161/70/74/76 ---ND------1876259/62/75 ---ND------14063---ND------46.7 64 ---ND------46.76544/47/65 ---ND------14066---ND------78.567---ND------46.768---ND------46.76949/69 ---ND------93.57061/70/74/76 ---ND------1877140/41/71 ---ND------14072---ND------46.77343/73 ---ND------46.77461/70/74/76 ---ND------1877559/62/75 ---ND------1407661/70/74/76 ---ND------18777---ND------46.778---ND------46.779---ND------46.780---ND------46.781---ND------46.782---ND------46.783---ND------46.784---ND------46.78585/116/117 ---ND------1408686/87/97/108/119/125 ---ND------2808786/87/97/108/119/125 ---ND------2808888/91 ---ND------93.5 89 ---ND------46.79090/101/113 ---ND------140 Page 49 of 59Report No.....10439419_1668_209_DFR Page 71 of 81 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits ng/L = Nanograms per liter Resultsreported ona totalweight basis ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference Method 1668A Polychlorobiphenyl Lab Sample ID Filename BLANK-63507 P180723B_07 Blank Analysis Results Co-elutions RT ng/Kg EMLEMPCConcentration ng/KgIUPACRatio ng/Kg 91 88/91 ---ND------93.592---ND------46.79393/98/100/102 ---ND------18794---ND------46.795---ND------88.896---ND------46.79786/87/97/108/119/125 ---ND------2809893/98/100/102 ---ND------18799---ND------46.710093/98/100/102 ---ND------18710190/101/113 ---ND------14010293/98/100/102 ---ND------187103---ND------46.7104---ND------46.7105---ND------46.7106---ND------46.7107107/124 ---ND------93.510886/87/97/108/119/125 ---ND------280 109 ---ND------46.7110110/115 ---ND------93.5111---ND------46.7112---ND------46.711390/101/113 ---ND------140114---ND------46.7115110/115 ---ND------93.511685/116/117 ---ND------14011785/116/117 ---ND------140118---ND------59.811986/87/97/108/119/125 ---ND------280120---ND------46.7121---ND------46.7122---ND------46.7123---ND------46.7124107/124 ---ND------93.512586/87/97/108/119/125 ---ND------280126---ND------46.7127---ND------46.7128128/166 ---ND------93.5129129/138/163 ---ND------140130---ND------46.7131---ND------46.7132---ND------46.7133---ND------46.7 134 134/143 ---ND------93.5135135/151 ---ND------93.5 Page 50 of 59Report No.....10439419_1668_209_DFR Page 72 of 81 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits ng/L = Nanograms per liter Resultsreported ona totalweight basis ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference Method 1668A Polychlorobiphenyl Lab Sample ID Filename BLANK-63507 P180723B_07 Blank Analysis Results Co-elutions RT ng/Kg EMLEMPCConcentration ng/KgIUPACRatio ng/Kg 136 ---ND------46.7137---ND------46.7138129/138/163 ---ND------140139139/140 ---ND------93.5140139/140 ---ND------93.5141---ND------46.7142---ND------46.7143134/143 ---ND------93.5144---ND------46.7145---ND------46.7146---ND------46.7147147/149 ---ND------93.5148---ND------46.7149147/149 ---ND------93.5150---ND------46.7151135/151 ---ND------93.5152---ND------46.7153153/168 ---ND------93.5 154 ---ND------46.7155---ND------46.7156156/157 ---ND------93.5157156/157 ---ND------93.5158---ND------46.7159---ND------46.7160---ND------46.7161---ND------46.7162---ND------46.7163129/138/163 ---ND------140164---ND------46.7165---ND------46.7166128/166 ---ND------93.5167---ND------46.7168153/168 ---ND------93.5169---ND------46.7170---ND------46.7171171/173 ---ND------93.5172---ND------46.7173171/173 ---ND------93.5174---ND------46.7175---ND------46.7176---ND------46.7177---ND------46.7178---ND------46.7 179 ---ND------46.7180180/193 ---ND------93.5 Page 51 of 59Report No.....10439419_1668_209_DFR Page 73 of 81 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits ng/L = Nanograms per liter Resultsreported ona totalweight basis ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference Method 1668A Polychlorobiphenyl Lab Sample ID Filename BLANK-63507 P180723B_07 Blank Analysis Results Co-elutions RT ng/Kg EMLEMPCConcentration ng/KgIUPACRatio ng/Kg 181 ---ND------46.7182---ND------46.7183183/185 ---ND------93.5184---ND------46.7185183/185 ---ND------93.5186---ND------46.7187---ND------46.7188---ND------46.7189---ND------46.7190---ND------46.7191---ND------46.7192---ND------46.7193180/193 ---ND------93.5194---ND------70.1195---ND------70.1196---ND------70.1197197/200 ---ND------140198198/199 ---ND------140 199 198/199 ---ND------140200197/200 ---ND------140201---ND------70.1202---ND------70.1203---ND------70.1204---ND------70.1205---ND------70.1206---ND------70.1207---ND------70.1208---ND------70.1209---ND------70.1 Page 52 of 59Report No.....10439419_1668_209_DFR Page 74 of 81 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Method 1668A Polychlorobiphenyl Client Sample ID Filename CBLKSW P180723B_07 Blank Analysis Results Lab Sample ID BLANK-63507 Congener Group Concentration ng/Kg Total MonochloroBiphenyls ND TotalDichloroBiphenyls ND Total TrichloroBiphenyls ND Total TetrachloroBiphenyls ND TotalPentachloroBiphenyls ND TotalHexachloroBiphenyls ND TotalHeptachloroBiphenyls ND Total Octachloro Biphenyls ND TotalNonachloroBiphenyls ND DecachloroBiphenyls ND TotalPCBs ND Results reported on a total weight basis ND = Not Detected Page 53 of 59Report No.....10439419_1668_209_DFR Page 75 of 81 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Method 1668A Polychlorobiphenyls Lab Sample ID Injected By FilenameTotal Amount Extracted ICAL ID CCal Filename(s) LCS-63513P180721B_03 BAL 945 mL P180721B02 P180721B_01 MatrixDilution Extracted Analyzed Water (QC Matrix) 07/17/2018 13:15 07/21/2018 19:55 NA Method Blank ID BLANK-63512 Laboratory Control Spike Analysis Results PCB Spiked Found Spiked Found % RecoveryIsomer(ng)(ng) % Recovery(ng)(ng) Native Analytes Labeled Analytes 1 1.0 0.996 2.0 0.992 50100 3 1.0 0.978 2.0 1.06 539841.0 1.07 2.0 0.945 47107151.0 1.03 2.0 1.12 56103 19 1.0 0.953 2.0 1.07 5395 37 1.0 0.813 2.0 1.35 6881 54 1.0 0.932 2.0 0.963 4893811.0 0.870 2.0 1.45 7387771.0 0.928 2.0 1.35 6793 104 1.0 0.985 2.0 0.926 4698 105 1.0 0.923 2.0 1.37 6992 114 1.0 1.01 2.0 1.32 661011181.0 0.968 2.0 1.36 68971231.0 0.959 2.0 1.33 6796 126 1.0 0.977 2.0 1.43 7298 155 1.0 0.921 2.0 0.950 4892 156/157 2.0 1.86 4.0 2.54 63931671.0 0.954 2.0 1.24 62951691.0 0.944 2.0 1.43 7194 188 1.0 1.00 2.0 0.960 48100 189 1.0 1.01 2.0 1.30 65101 202 1.0 0.991 2.0 1.00 50992051.0 1.03 2.0 1.20 601032061.0 1.03 2.0 1.13 56103 208 1.0 0.993 2.0 1.06 5399 209 1.0 1.05 2.0 1.08 54105 R =Recovery outside of method 1668A control limits Nn =Result obtained from alternate analysis ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion ng = Nanograms I=Interference Page 54 of 59Report No.....10439419_1668_209_DFR Page 76 of 81 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Method 1668A Polychlorobiphenyls Lab Sample ID Injected By FilenameTotal Amount Extracted ICAL ID CCal Filename(s) LCS-63508P180723B_03 BAL 10.0 g P180723B02 P180723B_01 MatrixDilution Extracted Analyzed Soil/Solid (QC Matrix) 07/17/2018 15:00 07/23/2018 19:25 NA Method Blank ID BLANK-63507 Laboratory Control Spike Analysis Results PCB Spiked Found Spiked Found % RecoveryIsomer(ng)(ng) % Recovery(ng)(ng) Native Analytes Labeled Analytes 1 1.0 0.926 2.0 1.17 5893 3 1.0 0.991 2.0 1.12 569941.0 0.964 2.0 1.16 58125I151.0 0.831 2.0 1.26 6383 19 1.0 0.658 2.0 1.58 7973I 37 1.0 0.769 2.0 1.33 6677 54 1.0 0.764 2.0 1.21 6176811.0 0.931 2.0 1.30 6593771.0 0.847 2.0 1.35 6885 104 1.0 0.979 2.0 1.13 5698 105 1.0 0.984 2.0 1.44 7298 114 1.0 0.845 2.0 1.40 7092I1181.0 0.916 2.0 1.42 71921231.0 1.04 2.0 1.43 72104 126 1.0 0.963 2.0 1.58 7996 155 1.0 0.962 2.0 1.10 5596 156/157 2.0 1.95 4.0 2.68 67981671.0 0.973 2.0 1.29 64971691.0 0.925 2.0 1.62 8193 188 1.0 0.948 2.0 1.13 5695 189 1.0 0.902 2.0 1.48 7490 202 1.0 0.922 2.0 1.25 63922051.0 1.07 2.0 1.41 711072061.0 1.04 2.0 1.37 69104 208 1.0 1.01 2.0 1.32 66101 209 1.0 0.974 2.0 1.45 7297 R =Recovery outside of method 1668A control limits Nn =Result obtained from alternate analysis ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion ng = Nanograms I=Interference Page 55 of 59Report No.....10439419_1668_209_DFR Page 77 of 81 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Method 1668A Polychlorobiphenyls Lab Sample ID Injected By FilenameTotal Amount Extracted ICAL ID CCal Filename(s) LCSD-63514P180721B_04 BAL 959 mL P180721B02 P180721B_01 MatrixDilution Extracted Analyzed Water (QC Matrix) 07/17/2018 13:15 07/21/2018 20:54 NA Method Blank ID BLANK-63512 Laboratory Control Spike Analysis Results PCB Spiked Found Spiked Found % RecoveryIsomer(ng)(ng) % Recovery(ng)(ng) Native Analytes Labeled Analytes 1 1.0 1.04 2.0 1.11 55104 3 1.0 1.04 2.0 1.12 5610441.0 1.13 2.0 0.983 49113151.0 1.09 2.0 1.15 57109 19 1.0 0.903 2.0 1.23 6190 37 1.0 0.939 2.0 1.11 6394 I 54 1.0 0.903 2.0 1.04 5290811.0 0.914 2.0 1.44 7291771.0 0.968 2.0 1.33 6797 104 1.0 0.991 2.0 1.00 5099 105 1.0 1.01 2.0 1.41 71101 114 1.0 1.02 2.0 1.42 711021181.0 0.938 2.0 1.45 73941231.0 0.953 2.0 1.45 7295 126 1.0 0.969 2.0 1.56 7897 155 1.0 1.04 2.0 0.987 49104 156/157 2.0 2.03 4.0 2.67 671021671.0 0.986 2.0 1.36 68991691.0 0.931 2.0 1.49 7493 188 1.0 1.01 2.0 1.13 56101 189 1.0 0.995 2.0 1.51 75100 202 1.0 0.961 2.0 1.19 60962051.0 1.02 2.0 1.33 671022061.0 1.07 2.0 1.26 63107 208 1.0 0.921 2.0 1.27 6392 209 1.0 0.944 2.0 1.20 6094 R =Recovery outside of method 1668A control limits Nn =Result obtained from alternate analysis ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion ng = Nanograms I=Interference Page 56 of 59Report No.....10439419_1668_209_DFR Page 78 of 81 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Method 1668A Polychlorobiphenyls Lab Sample ID Injected By FilenameTotal Amount Extracted ICAL ID CCal Filename(s) LCSD-63509P180723B_04 BAL 10.1 g P180723B02 P180723B_01 MatrixDilution Extracted Analyzed Solid 07/17/2018 15:00 07/23/2018 20:25 NA Method Blank ID BLANK-63507 Laboratory Control Spike Analysis Results PCB Spiked Found Spiked Found % RecoveryIsomer(ng)(ng) % Recovery(ng)(ng) Native Analytes Labeled Analytes 1 1.0 1.04 2.0 1.18 59104 3 1.0 0.920 2.0 1.30 659241.0 1.00 2.0 1.40 70100151.0 1.04 2.0 1.47 74104 19 1.0 0.719 2.0 1.97 9872 37 1.0 0.714 2.0 1.56 8771 I 54 1.0 0.901 2.0 1.34 6790811.0 0.842 2.0 1.50 7584771.0 0.816 2.0 1.66 8382 104 1.0 1.02 2.0 1.38 69102 105 1.0 0.987 2.0 1.69 8499 114 1.0 0.953 2.0 1.61 80951181.0 0.933 2.0 1.62 81931231.0 0.940 2.0 1.61 8194 126 1.0 0.866 2.0 1.96 9887 155 1.0 0.919 2.0 1.38 6992 156/157 2.0 1.80 4.0 3.16 79901671.0 0.933 2.0 1.60 80931691.0 0.949 2.0 1.73 8695 188 1.0 1.05 2.0 1.41 71105 189 1.0 0.888 2.0 1.71 8589 202 1.0 0.972 2.0 1.64 82972051.0 1.02 2.0 1.60 801022061.0 0.987 2.0 1.63 8299 208 1.0 1.01 2.0 1.64 82101 209 1.0 1.01 2.0 1.76 88101 R =Recovery outside of method 1668A control limits Nn =Result obtained from alternate analysis ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion ng = Nanograms I=Interference Page 57 of 59Report No.....10439419_1668_209_DFR Page 79 of 81 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Client Spike 1 ID Spike 1 Filename P180721B_03 LCS-63513 PACE Charlotte Spike Recovery Relative Percent Difference (RPD) Results Spike 2 ID Spike 2 Filename P180721B_04 LCSD-63514 Method 1668A Spike 1 Spike 2 Compound %REC %REC %RPDIUPAC 2-MoCB 100 104 3.914-MoCB 98 104 5.932,2'-DiCB 107 113 5.544,4'-DiCB 103 109 5.7152,2',6-TrCB 95 90 5.4193,4,4'-TrCB 81 94 14.9372,2',6,6'-TeCB 93 90 3.3543,3',4,4'-TeCB 93 97 4.2773,4,4',5-TeCB 87 91 4.5812,2',4,6,6'-PeCB 98 99 1.01042,3,3',4,4'-PeCB 92 101 9.31052,3,4,4',5-PeCB 101 102 1.01142,3',4,4',5-PeCB 97 94 3.11182,3',4,4',5'-PeCB 96 95 1.01233,3',4,4',5-PeCB 98 97 1.01262,2',4,4',6,6'-HxCB 92 104 12.2155(156/157)93 102 9.2156/1572,3',4,4',5,5'-HxCB 95 99 4.11673,3',4,4',5,5'-HxCB 94 93 1.11692,2',3,4',5,6,6'-HpCB 100 101 1.01882,3,3',4,4',5,5'-HpCB 101 100 1.01892,2',3,3',5,5',6,6'-OcCB 99 96 3.12022,3,3',4,4',5,5',6-OcCB 103 102 1.0205 2,2',3,3',4,4',5,5',6-NoCB 103 107 3.82062,2',3,3',4,5,5',6,6'-NoCB 99 92 7.3208Decachlorobiphenyl1059411.1209 %REC =Percent Recovered RPD =The difference between the two values dividedby the meanvalue Page 58 of 59Report No.....10439419_1668_209_DFR Page 80 of 81 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Client Spike 1 ID Spike 1 Filename P180723B_03 LCS-63508 PACE Charlotte Spike Recovery Relative Percent Difference (RPD) Results Spike 2 ID Spike 2 Filename P180723B_04 LCSD-63509 Method 1668A Spike 1 Spike 2 Compound %REC %REC %RPDIUPAC 2-MoCB 93 104 11.214-MoCB 99 92 7.332,2'-DiCB 125 100 22.244,4'-DiCB 83 104 22.5152,2',6-TrCB 73 72 1.4193,4,4'-TrCB 77 71 8.1372,2',6,6'-TeCB 76 90 16.9543,3',4,4'-TeCB 85 82 3.6773,4,4',5-TeCB 93 84 10.2812,2',4,6,6'-PeCB 98 102 4.01042,3,3',4,4'-PeCB 98 99 1.01052,3,4,4',5-PeCB 92 95 3.21142,3',4,4',5-PeCB 92 93 1.11182,3',4,4',5'-PeCB 104 94 10.11233,3',4,4',5-PeCB 96 87 9.81262,2',4,4',6,6'-HxCB 96 92 4.3155(156/157)98 90 8.5156/1572,3',4,4',5,5'-HxCB 97 93 4.21673,3',4,4',5,5'-HxCB 93 95 2.11692,2',3,4',5,6,6'-HpCB 95 105 10.01882,3,3',4,4',5,5'-HpCB 90 89 1.11892,2',3,3',5,5',6,6'-OcCB 92 97 5.32022,3,3',4,4',5,5',6-OcCB 107 102 4.8205 2,2',3,3',4,4',5,5',6-NoCB 104 99 4.92062,2',3,3',4,5,5',6,6'-NoCB 101 101 0.0208Decachlorobiphenyl971014.0209 %REC =Percent Recovered RPD =The difference between the two values dividedby the meanvalue Page 59 of 59Report No.....10439419_1668_209_DFR Page 81 of 81 #=CL# July 27, 2018 LIMS USE: FR - MICHAEL WORDEN LIMS OBJECT ID: 92391628 92391628 Project: Pace Project No.: RE: Michael W. Worden Environeering, Inc. 16100 Cairnway Suite 320 Houston, TX 77084 Eastern Drainage Ditch - SW Dear Michael Worden: Enclosed are the analytical results for sample(s) received by the laboratory on July 11, 2018. The results relate only to the samples included in this report. Results reported herein conform to the most current, applicable TNI/NELAC standards and the laboratory's Quality Assurance Manual, where applicable, unless otherwise noted in the body of the report. If you have any questions concerning this report, please feel free to contact me. Sincerely, Nicole Gasiorowski nicole.gasiorowski@pacelabs.com Project Manager (704)875-9092 Enclosures REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 1 of 58 #=CP# CERTIFICATIONS Pace Project No.: Project: 92391628 Eastern Drainage Ditch - SW Grand Rapids Certification ID's 5560 Corporate Exchange Ct SE, Grand Rapids, MI 49512 Minnesota Department of Health, Certificate #1385941 Arkansas Department of Environmental Quality, Certificate #18-046-0 Georgia Environmental Protection Division, Stipulation Illinois Environmental Protection Agency, Certificate #004325 Michigan Department of Environmental Quality, Laboratory #0034 New York State Department of Health, Serial #57971 and 57972 North Carolina Division of Water Resources, Certificate #659 Virginia Department of General Services, Certificate #9780 Wisconsin Department of Natural Resources, Laboratory #999472650 U.S. Department of Agriculture Permit to Receive Soil, Permit #P330-17-00278 Charlotte Certification IDs 9800 Kincey Ave. Ste 100, Huntersville, NC 28078 Louisiana/NELAP Certification # LA170028 North Carolina Drinking Water Certification #: 37706 North Carolina Field Services Certification #: 5342 North Carolina Wastewater Certification #: 12 South Carolina Certification #: 99006001 Florida/NELAP Certification #: E87627 Kentucky UST Certification #: 84 Virginia/VELAP Certification #: 460221 Asheville Certification IDs 2225 Riverside Drive, Asheville, NC 28804 Florida/NELAP Certification #: E87648 Massachusetts Certification #: M-NC030 North Carolina Drinking Water Certification #: 37712 North Carolina Wastewater Certification #: 40 South Carolina Certification #: 99030001 Virginia/VELAP Certification #: 460222 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 2 of 58 #=SS# SAMPLE SUMMARY Pace Project No.: Project: 92391628 Eastern Drainage Ditch - SW Lab ID Sample ID Matrix Date Collected Date Received 92391628001 ABL-SW013-F005 Water 07/11/18 13:25 07/11/18 16:35 92391628002 ABL-SW014-F005 Water 07/11/18 12:50 07/11/18 16:35 92391628003 ABL-SW015-F005 Water 07/11/18 12:20 07/11/18 16:35 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 3 of 58 #=SA# SAMPLE ANALYTE COUNT Pace Project No.: Project: 92391628 Eastern Drainage Ditch - SW Lab ID Sample ID Method Analytes Reported LaboratoryAnalysts 92391628001 ABL-SW013-F005 EPA 8082A 8 PASI-CNU1 EPA 8270D by SIM 20 PASI-CRES EPA 300.0 Rev 2.1 1993 1 PASI-ACDC EPA 9012B 1 PASI-ACJH1 OIA1677 1 PASI-GRMIIDT 92391628002 ABL-SW014-F005 EPA 8082A 8 PASI-CNU1 EPA 8270D by SIM 20 PASI-CRES EPA 300.0 Rev 2.1 1993 1 PASI-ACDC EPA 9012B 1 PASI-ACJH1 OIA1677 1 PASI-GRMIIDT 92391628003 ABL-SW015-F005 EPA 8082A 8 PASI-CNU1 EPA 8270D by SIM 20 PASI-CRES EPA 300.0 Rev 2.1 1993 1 PASI-ACDC EPA 9012B 1 PASI-ACJH1 OIA1677 1 PASI-GRMIIDT REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 4 of 58 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92391628 Eastern Drainage Ditch - SW Sample:ABL-SW013-F005 Lab ID:92391628001 Collected:07/11/18 13:25 Received:07/11/18 16:35 Matrix:Water Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 8082A Preparation Method: EPA 3510C8082 GCS PCB RVE PCB-1016 (Aroclor 1016)ND ug/L 07/16/18 19:18 12674-11-207/12/18 19:400.50 0.50 1 PCB-1221 (Aroclor 1221)ND ug/L 07/16/18 19:18 11104-28-207/12/18 19:400.50 0.50 1 PCB-1232 (Aroclor 1232)ND ug/L 07/16/18 19:18 11141-16-507/12/18 19:400.50 0.50 1 PCB-1242 (Aroclor 1242)ND ug/L 07/16/18 19:18 53469-21-907/12/18 19:400.50 0.50 1 PCB-1248 (Aroclor 1248)ND ug/L 07/16/18 19:18 12672-29-607/12/18 19:400.50 0.50 1 PCB-1254 (Aroclor 1254)ND ug/L 07/16/18 19:18 11097-69-107/12/18 19:400.50 0.50 1 PCB-1260 (Aroclor 1260)ND ug/L 07/16/18 19:18 11096-82-507/12/18 19:400.50 0.50 1 Surrogates Decachlorobiphenyl (S)60 %07/16/18 19:18 2051-24-307/12/18 19:4010-132 1 Analytical Method: EPA 8270D by SIM Preparation Method: EPA 3511 Leachate Method/Date: EPA 1312; 07/19/18 10:52 8270 SPLP SIM PAH Low Volume Acenaphthene ND ug/L 07/20/18 17:13 83-32-907/20/18 07:400.50 0.50 1 Acenaphthylene ND ug/L 07/20/18 17:13 208-96-807/20/18 07:400.50 0.50 1 Anthracene ND ug/L 07/20/18 17:13 120-12-707/20/18 07:400.050 0.050 1 Benzo(a)anthracene ND ug/L 07/20/18 17:13 56-55-307/20/18 07:400.050 0.050 1 Benzo(a)pyrene ND ug/L 07/20/18 17:13 50-32-807/20/18 07:400.10 0.10 1 Benzo(b)fluoranthene ND ug/L 07/20/18 17:13 205-99-207/20/18 07:400.050 0.050 1 Benzo(g,h,i)perylene ND ug/L 07/20/18 17:13 191-24-207/20/18 07:400.20 0.20 1 Benzo(k)fluoranthene ND ug/L 07/20/18 17:13 207-08-907/20/18 07:400.20 0.20 1 Chrysene ND ug/L 07/20/18 17:13 218-01-907/20/18 07:400.10 0.10 1 Dibenz(a,h)anthracene ND ug/L 07/20/18 17:13 53-70-307/20/18 07:400.15 0.15 1 Fluoranthene ND ug/L 07/20/18 17:13 206-44-007/20/18 07:400.30 0.30 1 Fluorene ND ug/L 07/20/18 17:13 86-73-707/20/18 07:400.31 0.31 1 Indeno(1,2,3-cd)pyrene ND ug/L 07/20/18 17:13 193-39-507/20/18 07:400.050 0.050 1 1-Methylnaphthalene ND ug/L 07/20/18 17:13 90-12-007/20/18 07:402.0 2.0 1 2-Methylnaphthalene ND ug/L 07/20/18 17:13 91-57-607/20/18 07:402.0 2.0 1 Naphthalene ND ug/L 07/20/18 17:13 91-20-307/20/18 07:401.5 1.5 1 Phenanthrene ND ug/L 07/20/18 17:13 85-01-807/20/18 07:400.20 0.20 1 Pyrene ND ug/L 07/20/18 17:13 129-00-007/20/18 07:400.10 0.10 1 Surrogates Nitrobenzene-d5 (S)110 %07/20/18 17:13 4165-60-007/20/18 07:4070-130 1 2-Fluorobiphenyl (S)79 %07/20/18 17:13 321-60-807/20/18 07:4070-130 1 Analytical Method: EPA 300.0 Rev 2.1 1993300.0 IC Anions 28 Days Fluoride 1.2 mg/L 07/19/18 20:01 16984-48-80.10 0.050 1 Analytical Method: EPA 9012B Preparation Method: EPA 9012B9012B Cyanide, Total Cyanide 0.064 mg/L 07/17/18 15:20 57-12-507/17/18 11:150.0080 0.0040 1 Analytical Method: OIA1677OIA1677 Cyanide, Available Available Cyanide 3.4 ug/L 07/17/18 13:272.0 0.30 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 07/27/2018 12:30 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 5 of 58 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92391628 Eastern Drainage Ditch - SW Sample:ABL-SW014-F005 Lab ID:92391628002 Collected:07/11/18 12:50 Received:07/11/18 16:35 Matrix:Water Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 8082A Preparation Method: EPA 3510C8082 GCS PCB RVE PCB-1016 (Aroclor 1016)ND ug/L 07/16/18 19:30 12674-11-207/12/18 19:400.42 0.42 1 PCB-1221 (Aroclor 1221)ND ug/L 07/16/18 19:30 11104-28-207/12/18 19:400.42 0.42 1 PCB-1232 (Aroclor 1232)ND ug/L 07/16/18 19:30 11141-16-507/12/18 19:400.42 0.42 1 PCB-1242 (Aroclor 1242)ND ug/L 07/16/18 19:30 53469-21-907/12/18 19:400.42 0.42 1 PCB-1248 (Aroclor 1248)ND ug/L 07/16/18 19:30 12672-29-607/12/18 19:400.42 0.42 1 PCB-1254 (Aroclor 1254)ND ug/L 07/16/18 19:30 11097-69-107/12/18 19:400.42 0.42 1 PCB-1260 (Aroclor 1260)ND ug/L 07/16/18 19:30 11096-82-507/12/18 19:400.42 0.42 1 Surrogates Decachlorobiphenyl (S)50 %07/16/18 19:30 2051-24-307/12/18 19:4010-132 1 Analytical Method: EPA 8270D by SIM Preparation Method: EPA 3511 Leachate Method/Date: EPA 1312; 07/19/18 10:52 8270 SPLP SIM PAH Low Volume Acenaphthene ND ug/L 07/20/18 17:55 83-32-907/20/18 07:400.50 0.50 1 Acenaphthylene ND ug/L 07/20/18 17:55 208-96-807/20/18 07:400.50 0.50 1 Anthracene ND ug/L 07/20/18 17:55 120-12-707/20/18 07:400.050 0.050 1 Benzo(a)anthracene ND ug/L 07/20/18 17:55 56-55-307/20/18 07:400.050 0.050 1 Benzo(a)pyrene ND ug/L 07/20/18 17:55 50-32-807/20/18 07:400.10 0.10 1 Benzo(b)fluoranthene ND ug/L 07/20/18 17:55 205-99-207/20/18 07:400.050 0.050 1 Benzo(g,h,i)perylene ND ug/L 07/20/18 17:55 191-24-207/20/18 07:400.20 0.20 1 Benzo(k)fluoranthene ND ug/L 07/20/18 17:55 207-08-907/20/18 07:400.20 0.20 1 Chrysene ND ug/L 07/20/18 17:55 218-01-907/20/18 07:400.10 0.10 1 Dibenz(a,h)anthracene ND ug/L 07/20/18 17:55 53-70-307/20/18 07:400.15 0.15 1 Fluoranthene ND ug/L 07/20/18 17:55 206-44-007/20/18 07:400.30 0.30 1 Fluorene ND ug/L 07/20/18 17:55 86-73-707/20/18 07:400.31 0.31 1 Indeno(1,2,3-cd)pyrene ND ug/L 07/20/18 17:55 193-39-507/20/18 07:400.050 0.050 1 1-Methylnaphthalene ND ug/L 07/20/18 17:55 90-12-007/20/18 07:402.0 2.0 1 2-Methylnaphthalene ND ug/L 07/20/18 17:55 91-57-607/20/18 07:402.0 2.0 1 Naphthalene ND ug/L 07/20/18 17:55 91-20-307/20/18 07:401.5 1.5 1 Phenanthrene ND ug/L 07/20/18 17:55 85-01-807/20/18 07:400.20 0.20 1 Pyrene ND ug/L 07/20/18 17:55 129-00-007/20/18 07:400.10 0.10 1 Surrogates Nitrobenzene-d5 (S)115 %07/20/18 17:55 4165-60-007/20/18 07:4070-130 1 2-Fluorobiphenyl (S)85 %07/20/18 17:55 321-60-807/20/18 07:4070-130 1 Analytical Method: EPA 300.0 Rev 2.1 1993300.0 IC Anions 28 Days Fluoride 2.2 mg/L 07/19/18 20:55 16984-48-80.10 0.050 1 Analytical Method: EPA 9012B Preparation Method: EPA 9012B9012B Cyanide, Total Cyanide 0.051 mg/L 07/17/18 15:23 57-12-507/17/18 11:150.0080 0.0040 1 Analytical Method: OIA1677OIA1677 Cyanide, Available Available Cyanide 3.8 ug/L 07/17/18 13:312.0 0.30 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 07/27/2018 12:30 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 6 of 58 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92391628 Eastern Drainage Ditch - SW Sample:ABL-SW015-F005 Lab ID:92391628003 Collected:07/11/18 12:20 Received:07/11/18 16:35 Matrix:Water Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 8082A Preparation Method: EPA 3510C8082 GCS PCB RVE PCB-1016 (Aroclor 1016)ND ug/L 07/16/18 19:43 12674-11-207/12/18 19:400.50 0.50 1 PCB-1221 (Aroclor 1221)ND ug/L 07/16/18 19:43 11104-28-207/12/18 19:400.50 0.50 1 PCB-1232 (Aroclor 1232)ND ug/L 07/16/18 19:43 11141-16-507/12/18 19:400.50 0.50 1 PCB-1242 (Aroclor 1242)ND ug/L 07/16/18 19:43 53469-21-907/12/18 19:400.50 0.50 1 PCB-1248 (Aroclor 1248)ND ug/L 07/16/18 19:43 12672-29-607/12/18 19:400.50 0.50 1 PCB-1254 (Aroclor 1254)ND ug/L 07/16/18 19:43 11097-69-107/12/18 19:400.50 0.50 1 PCB-1260 (Aroclor 1260)ND ug/L 07/16/18 19:43 11096-82-507/12/18 19:400.50 0.50 1 Surrogates Decachlorobiphenyl (S)45 %07/16/18 19:43 2051-24-307/12/18 19:4010-132 1 Analytical Method: EPA 8270D by SIM Preparation Method: EPA 3511 Leachate Method/Date: EPA 1312; 07/19/18 10:52 8270 SPLP SIM PAH Low Volume Acenaphthene ND ug/L 07/20/18 18:16 83-32-907/20/18 07:400.50 0.50 1 Acenaphthylene ND ug/L 07/20/18 18:16 208-96-807/20/18 07:400.50 0.50 1 Anthracene ND ug/L 07/20/18 18:16 120-12-707/20/18 07:400.050 0.050 1 Benzo(a)anthracene ND ug/L 07/20/18 18:16 56-55-307/20/18 07:400.050 0.050 1 Benzo(a)pyrene ND ug/L 07/20/18 18:16 50-32-807/20/18 07:400.10 0.10 1 Benzo(b)fluoranthene ND ug/L 07/20/18 18:16 205-99-207/20/18 07:400.050 0.050 1 Benzo(g,h,i)perylene ND ug/L 07/20/18 18:16 191-24-207/20/18 07:400.20 0.20 1 Benzo(k)fluoranthene ND ug/L 07/20/18 18:16 207-08-907/20/18 07:400.20 0.20 1 Chrysene ND ug/L 07/20/18 18:16 218-01-907/20/18 07:400.10 0.10 1 Dibenz(a,h)anthracene ND ug/L 07/20/18 18:16 53-70-307/20/18 07:400.15 0.15 1 Fluoranthene ND ug/L 07/20/18 18:16 206-44-007/20/18 07:400.30 0.30 1 Fluorene ND ug/L 07/20/18 18:16 86-73-707/20/18 07:400.31 0.31 1 Indeno(1,2,3-cd)pyrene ND ug/L 07/20/18 18:16 193-39-507/20/18 07:400.050 0.050 1 1-Methylnaphthalene ND ug/L 07/20/18 18:16 90-12-007/20/18 07:402.0 2.0 1 2-Methylnaphthalene ND ug/L 07/20/18 18:16 91-57-607/20/18 07:402.0 2.0 1 Naphthalene ND ug/L 07/20/18 18:16 91-20-307/20/18 07:401.5 1.5 1 Phenanthrene ND ug/L 07/20/18 18:16 85-01-807/20/18 07:400.20 0.20 1 Pyrene ND ug/L 07/20/18 18:16 129-00-007/20/18 07:400.10 0.10 1 Surrogates Nitrobenzene-d5 (S)101 %07/20/18 18:16 4165-60-007/20/18 07:4070-130 1 2-Fluorobiphenyl (S)75 %07/20/18 18:16 321-60-807/20/18 07:4070-130 1 Analytical Method: EPA 300.0 Rev 2.1 1993300.0 IC Anions 28 Days Fluoride 6.0 mg/L 07/19/18 21:13 16984-48-80.20 0.10 2 Analytical Method: EPA 9012B Preparation Method: EPA 9012B9012B Cyanide, Total Cyanide 0.014 mg/L 07/17/18 15:24 57-12-507/17/18 11:150.0080 0.0040 1 Analytical Method: OIA1677OIA1677 Cyanide, Available Available Cyanide 0.80J ug/L 07/17/18 13:322.0 0.30 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 07/27/2018 12:30 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 7 of 58 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92391628 Eastern Drainage Ditch - SW Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 418714 EPA 3510C EPA 8082A 8082 GCS PCB Associated Lab Samples:92391628001, 92391628002, 92391628003 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:2321052 Associated Lab Samples:92391628001, 92391628002, 92391628003 Matrix:Water AnalyzedMDL PCB-1016 (Aroclor 1016)ug/L ND 0.50 07/16/18 23:330.50 PCB-1221 (Aroclor 1221)ug/L ND 0.50 07/16/18 23:330.50 PCB-1232 (Aroclor 1232)ug/L ND 0.50 07/16/18 23:330.50 PCB-1242 (Aroclor 1242)ug/L ND 0.50 07/16/18 23:330.50 PCB-1248 (Aroclor 1248)ug/L ND 0.50 07/16/18 23:330.50 PCB-1254 (Aroclor 1254)ug/L ND 0.50 07/16/18 23:330.50 PCB-1260 (Aroclor 1260)ug/L ND 0.50 07/16/18 23:330.50 Decachlorobiphenyl (S)%73 10-132 07/16/18 23:33 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 2321053LABORATORY CONTROL SAMPLE & LCSD: LCSSpike LCSD % Rec RPD Max RPD LCSD Result 2321054 PCB-1016 (Aroclor 1016)ug/L 3.65 72 50-150683.4 6 30 PCB-1260 (Aroclor 1260)ug/L 4.05 80 50-150743.7 9 30 Decachlorobiphenyl (S)%76 10-13281 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 07/27/2018 12:30 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 8 of 58 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92391628 Eastern Drainage Ditch - SW Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 420210 EPA 3511 EPA 8270D by SIM 8270 SPLP SIM PAH Low Volume Associated Lab Samples:92391628001, 92391628002, 92391628003 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:2328166 Associated Lab Samples:92391628001, 92391628002, 92391628003 Matrix:Water AnalyzedMDL 1-Methylnaphthalene ug/L ND 2.0 07/20/18 15:492.0 2-Methylnaphthalene ug/L ND 2.0 07/20/18 15:492.0 Acenaphthene ug/L ND 0.50 07/20/18 15:490.50 Acenaphthylene ug/L ND 0.50 07/20/18 15:490.50 Anthracene ug/L ND 0.050 07/20/18 15:490.050 Benzo(a)anthracene ug/L ND 0.050 07/20/18 15:490.050 Benzo(a)pyrene ug/L ND 0.10 07/20/18 15:490.10 Benzo(b)fluoranthene ug/L ND 0.050 07/20/18 15:490.050 Benzo(g,h,i)perylene ug/L ND 0.20 07/20/18 15:490.20 Benzo(k)fluoranthene ug/L ND 0.20 07/20/18 15:490.20 Chrysene ug/L ND 0.10 07/20/18 15:490.10 Dibenz(a,h)anthracene ug/L ND 0.15 07/20/18 15:490.15 Fluoranthene ug/L ND 0.30 07/20/18 15:490.30 Fluorene ug/L ND 0.31 07/20/18 15:490.31 Indeno(1,2,3-cd)pyrene ug/L ND 0.050 07/20/18 15:490.050 Naphthalene ug/L ND 1.5 07/20/18 15:491.5 Phenanthrene ug/L ND 0.20 07/20/18 15:490.20 Pyrene ug/L ND 0.10 07/20/18 15:490.10 2-Fluorobiphenyl (S)%77 70-130 07/20/18 15:49 Nitrobenzene-d5 (S)%94 70-130 07/20/18 15:49 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 2328167LABORATORY CONTROL SAMPLE: LCSSpike 1-Methylnaphthalene ug/L 2.42.5 94 70-130 2-Methylnaphthalene ug/L 2.32.5 91 70-130 Acenaphthene ug/L 2.52.5 99 70-130 Acenaphthylene ug/L 2.42.5 95 70-130 Anthracene ug/L 2.62.5 103 70-130 Benzo(a)anthracene ug/L 2.42.5 98 70-130 Benzo(a)pyrene ug/L 2.52.5 100 70-130 Benzo(b)fluoranthene ug/L 2.42.5 95 70-130 Benzo(g,h,i)perylene ug/L 2.32.5 94 70-130 Benzo(k)fluoranthene ug/L 2.42.5 97 70-130 Chrysene ug/L 2.72.5 107 70-130 Dibenz(a,h)anthracene ug/L 2.52.5 101 70-130 Fluoranthene ug/L 2.52.5 102 70-130 Fluorene ug/L 2.52.5 99 70-130 Indeno(1,2,3-cd)pyrene ug/L 2.62.5 106 70-130 Naphthalene ug/L 2.02.5 82 70-130 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 07/27/2018 12:30 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 9 of 58 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92391628 Eastern Drainage Ditch - SW Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 2328167LABORATORY CONTROL SAMPLE: LCSSpike Phenanthrene ug/L 2.42.5 95 70-130 Pyrene ug/L 2.52.5 100 70-130 2-Fluorobiphenyl (S)%79 70-130 Nitrobenzene-d5 (S)%107 70-130 Parameter Units MS Result % Rec Limits Qualifiers% RecConc. 2328168MATRIX SPIKE SAMPLE: MSSpike Result 92391608004 1-Methylnaphthalene ug/L 2.82.5 113 70-130ND 2-Methylnaphthalene ug/L 2.82.5 111 70-130ND Acenaphthene ug/L 3.02.5 120 70-130ND Acenaphthylene ug/L 2.92.5 117 70-130ND Anthracene ug/L 3.22.5 126 70-130ND Benzo(a)anthracene ug/L 2.82.5 113 70-130ND Benzo(a)pyrene ug/L 2.82.5 113 70-130ND Benzo(b)fluoranthene ug/L 2.82.5 111 70-130ND Benzo(g,h,i)perylene ug/L 2.62.5 104 70-130ND Benzo(k)fluoranthene ug/L 2.72.5 109 70-130ND Chrysene ug/L 3.12.5 126 70-130ND Dibenz(a,h)anthracene ug/L 2.82.5 112 70-130ND Fluoranthene ug/L 3.02.5 119 70-130ND Fluorene ug/L 3.02.5 122 70-130ND Indeno(1,2,3-cd)pyrene ug/L 2.92.5 115 70-130ND Naphthalene ug/L 2.52.5 98 70-130ND Phenanthrene ug/L 2.92.5 114 70-130ND Pyrene ug/L 2.92.5 117 70-130ND 2-Fluorobiphenyl (S)%84 70-130 Nitrobenzene-d5 (S)%115 70-130 Parameter Units Dup Result Max RPD QualifiersRPDResult 92391628001 2328169SAMPLE DUPLICATE: 1-Methylnaphthalene ug/L ND 30ND 2-Methylnaphthalene ug/L ND 30ND Acenaphthene ug/L ND 30ND Acenaphthylene ug/L ND 30ND Anthracene ug/L ND 30ND Benzo(a)anthracene ug/L ND 30ND Benzo(a)pyrene ug/L ND 30ND Benzo(b)fluoranthene ug/L ND 30ND Benzo(g,h,i)perylene ug/L ND 30ND Benzo(k)fluoranthene ug/L ND 30ND Chrysene ug/L ND 30ND Dibenz(a,h)anthracene ug/L ND 30ND REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 07/27/2018 12:30 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 10 of 58 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92391628 Eastern Drainage Ditch - SW Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units Dup Result Max RPD QualifiersRPDResult 92391628001 2328169SAMPLE DUPLICATE: Fluoranthene ug/L ND 30ND Fluorene ug/L ND 30ND Indeno(1,2,3-cd)pyrene ug/L ND 30ND Naphthalene ug/L ND 30ND Phenanthrene ug/L ND 30ND Pyrene ug/L ND 30ND 2-Fluorobiphenyl (S)%85 779 Nitrobenzene-d5 (S)%109 1110 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 07/27/2018 12:30 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 11 of 58 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92391628 Eastern Drainage Ditch - SW Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 419979 EPA 300.0 Rev 2.1 1993 EPA 300.0 Rev 2.1 1993 300.0 IC Anions Associated Lab Samples:92391628001, 92391628002, 92391628003 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:2327124 Associated Lab Samples:92391628001, 92391628002, 92391628003 Matrix:Water AnalyzedMDL Fluoride mg/L ND 0.10 07/19/18 14:530.050 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 2327125LABORATORY CONTROL SAMPLE: LCSSpike Fluoride mg/L 2.62.5 104 90-110 Parameter Units MS Result % Rec Limits Qual% RecConc. 2327126MATRIX SPIKE & MATRIX SPIKE DUPLICATE: MSSpike Result 92392394001 2327127 MSD Result MSD % Rec RPD RPD Max MSDMS Spike Conc. Fluoride mg/L 2.5 99 90-110106 7 102.50.13 2.6 2.8 Parameter Units MS Result % Rec Limits Qual% RecConc. 2327128MATRIX SPIKE & MATRIX SPIKE DUPLICATE: MSSpike Result 92391628001 2327129 MSD Result MSD % Rec RPD RPD Max MSDMS Spike Conc. Fluoride mg/L 2.5 98 90-110101 2 102.51.2 3.7 3.8 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 07/27/2018 12:30 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 12 of 58 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92391628 Eastern Drainage Ditch - SW Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 419425 EPA 9012B EPA 9012B EPA 9012B Cyanide Associated Lab Samples:92391628001, 92391628002, 92391628003 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:2324546 Associated Lab Samples:92391628001, 92391628002, 92391628003 Matrix:Water AnalyzedMDL Cyanide mg/L ND 0.0080 07/17/18 15:180.0040 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 2324547LABORATORY CONTROL SAMPLE: LCSSpike Cyanide mg/L 0.092.1 92 80-120 Parameter Units MS Result % Rec Limits Qual% RecConc. 2324548MATRIX SPIKE & MATRIX SPIKE DUPLICATE: MSSpike Result 92391628001 2324549 MSD Result MSD % Rec RPD RPD Max MSDMS Spike Conc. Cyanide mg/L .1 87 75-12590 2 20.10.064 0.15 0.15 Parameter Units MS Result % Rec Limits Qual% RecConc. 2324550MATRIX SPIKE & MATRIX SPIKE DUPLICATE: MSSpike Result 92391634008 2324551 MSD Result MSD % Rec RPD RPD Max MSDMS Spike Conc. Cyanide mg/L .1 95 75-12592 3 20.1ND 0.095 0.092 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 07/27/2018 12:30 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 13 of 58 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92391628 Eastern Drainage Ditch - SW Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 28260 OIA1677 OIA1677 OIA1677 Cyanide, Available Associated Lab Samples:92391628001, 92391628002, 92391628003 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:112956 Associated Lab Samples:92391628001, 92391628002, 92391628003 Matrix:Water AnalyzedMDL Available Cyanide ug/L ND 2.0 07/17/18 13:250.30 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 112957LABORATORY CONTROL SAMPLE: LCSSpike Available Cyanide ug/L 19.420 97 82-132 Parameter Units MS Result % Rec Limits Qual% RecConc. 112958MATRIX SPIKE & MATRIX SPIKE DUPLICATE: MSSpike Result 92391628001 112959 MSD Result MSD % Rec RPD RPD Max MSDMS Spike Conc. Available Cyanide ug/L 20 100 82-130103 3 11203.4 23.4 24.1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 07/27/2018 12:30 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 14 of 58 #=QL# QUALIFIERS Pace Project No.: Project: 92391628 Eastern Drainage Ditch - SW DEFINITIONS DF - Dilution Factor, if reported, represents the factor applied to the reported data due to dilution of the sample aliquot. ND - Not Detected at or above adjusted reporting limit. TNTC - Too Numerous To Count J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit. MDL - Adjusted Method Detection Limit. PQL - Practical Quantitation Limit. RL - Reporting Limit - The lowest concentration value that meets project requirements for quantitative data with known precision and bias for a specific analyte in a specific matrix. S - Surrogate 1,2-Diphenylhydrazine decomposes to and cannot be separated from Azobenzene using Method 8270. The result for each analyte is a combined concentration. Consistent with EPA guidelines, unrounded data are displayed and have been used to calculate % recovery and RPD values. LCS(D) - Laboratory Control Sample (Duplicate) MS(D) - Matrix Spike (Duplicate) DUP - Sample Duplicate RPD - Relative Percent Difference NC - Not Calculable. SG - Silica Gel - Clean-Up U - Indicates the compound was analyzed for, but not detected. Acid preservation may not be appropriate for 2 Chloroethylvinyl ether. A separate vial preserved to a pH of 4-5 is recommended in SW846 Chapter 4 for the analysis of Acrolein and Acrylonitrile by EPAMethod 8260. N-Nitrosodiphenylamine decomposes and cannot be separated from Diphenylamine using Method 8270. The result reported for each analyte is a combined concentration. Pace Analytical is TNI accredited. Contact your Pace PM for the current list of accredited analytes. TNI - The NELAC Institute. LABORATORIES Pace Analytical Services - AshevillePASI-A Pace Analytical Services - CharlottePASI-C Pace Analytical - Grand RapidsPASI-GRMI REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 07/27/2018 12:30 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 15 of 58 #=CR# QUALITY CONTROL DATA CROSS REFERENCE TABLE Pace Project No.: Project: 92391628 Eastern Drainage Ditch - SW Lab ID Sample ID QC Batch Method QC Batch Analytical Method Analytical Batch 92391628001 418714 419331ABL-SW013-F005 EPA 3510C EPA 8082A 92391628002 418714 419331ABL-SW014-F005 EPA 3510C EPA 8082A 92391628003 418714 419331ABL-SW015-F005 EPA 3510C EPA 8082A 92391628001 420210 420315ABL-SW013-F005 EPA 3511 EPA 8270D by SIM 92391628002 420210 420315ABL-SW014-F005 EPA 3511 EPA 8270D by SIM 92391628003 420210 420315ABL-SW015-F005 EPA 3511 EPA 8270D by SIM 92391628001 419979ABL-SW013-F005 EPA 300.0 Rev 2.1 1993 92391628002 419979ABL-SW014-F005 EPA 300.0 Rev 2.1 1993 92391628003 419979ABL-SW015-F005 EPA 300.0 Rev 2.1 1993 92391628001 419425 419520ABL-SW013-F005 EPA 9012B EPA 9012B 92391628002 419425 419520ABL-SW014-F005 EPA 9012B EPA 9012B 92391628003 419425 419520ABL-SW015-F005 EPA 9012B EPA 9012B 92391628001 28260ABL-SW013-F005 OIA1677 92391628002 28260ABL-SW014-F005 OIA1677 92391628003 28260ABL-SW015-F005 OIA1677 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 07/27/2018 12:30 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 16 of 58 Page 17 of 58 Page 18 of 58 Page 19 of 58 Thisreportshouldnotbereproduced,exceptinfull, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Theresultsrelateonlytothesamplesincludedinthisreport. Report of Laboratory Analysis www.pacelabs.com Pace Analytical Services,Inc. 1700 Elm Street Minneapolis, MN 55414 Phone: 612.607.1700 Fax: 612.607.6444 Client - Charlotte PACE Charlotte 9800 Kincey Ave. Huntersville NC 28078 REPORT OF LABORATORY ANALYSIS FOR PCBs This report has been reviewed by: Invoicing & Reporting Options: Report Information: Report Prepared Date: July 25, 2018 Pace Project #: 10439456 Sample Receipt Date: 07/13/2018 Client Project #: 92391628 Alcoa-Badin Works Client Sub PO #: N/A The report provided has been invoiced as a Level 2 PCB Report. If an upgrade of this report package is requested, an additional charge may be applied. Please review the attached invoice for accuracy and forward anyquestions toNathan Boberg,your Pace Project Manager. State Cert #: 27700 Report Prepared for: Page 1 of 39Report No.....10439456_1668_209_DFR July 26, 2018 Nathan Boberg, Project Manager (612) 607-6444 (fax) nathan.boberg@pacelabs.com Page 20 of 58 Pace Analytical Services,Inc. 1700 Elm Street Minneapolis, MN 55414 Phone: 612.607.1700 Fax: 612.607.6444 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. This report presents the results from the analyses performed on three samples submitted by a representative of Pace Analytical - NC. The samples were analyzed for the presence or absence of polychlorinated biphenyl (PCB) congeners using USEPA Method 1668A. Reporting limits were set to 0.25-0.75 parts-per-trillion and were adjusted for the amount of sample extracted. The dilution level noted on the data tables is being adjusted to allow the correct data flags to populate the electronic deliverables as well as the data tables. Samples and MDL extracts were analyzed at elevated volumes. That volume is being treated as a 1x dilution for calculation purposes, with larger dilutions being factored from that volume. The standard reporting limits were not adjusted since the limits remained within the calibration range even after dilutions were applied. The recoveries of the isotopically-labeled PCB internal standards in the sample extracts ranged from 39-93%. All of the labeled standard recoveries obtained for this project were within the target ranges specified in Method 1668A. Since the quantification of the native congeners was based on isotope dilution and internal standard methodology, the data were automatically corrected for variation in recovery and accurate values were obtained. Incorrect isotope ratios were obtained for selected PCB congeners. The affected congeners were flagged "I" on the results table. A laboratory method blank was prepared and analyzed with the sample batch as part of our routine quality control procedures. The results show the blank to be free of PCB congeners at the reporting limits. This indicates that the sample preparation procedures did not significantly contribute to the PCB content of the sample material. Laboratory spike samples were also prepared with the sample batch using reference material that had been fortified with native standards. The results show that the spiked native compounds were recovered at 81-113%, with relative percent differences of 0.0-14.9%. These values were within method limits. Matrix spikes were not extracted with this sample batch. DISCUSSION Page 2 of 39Report No.....10439456_1668_209_DFR Page 21 of 58 REPORT OFLABORATORY ANALYSIS This report shallnot bereproduced,exceptin full, withoutthe written consentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Report No.....10439456 Minnesota Laboratory Certifications Authority Certificate #Authority Certificate # A2LA 2926.01 Mississippi MN00064 Alabama 40770 Montana CERT0092 Alaska MN00064 Nebraska NE-OS-18-06 Alaska UST-078 Nevada MN00064 Arizona AZ0014 New Jersey (NE MN002 Arkansas 88-0680 New York (NEL 11647 CNMI Saipan MP0003 New hampshire 2081 California MN00064 North Carolina 27700 Colorado MN00064 North Carolina 530 Connecticut PH-0256 North Dakota R-036 EPA Region 8 8TMS-L Ohio 41244 Florida (NELAP E87605 Ohio VAP CL101 Georgia (EDP)959 Oklahoma 9507 Guam EPA 959 Oregon (ELAP)MN200001 Hawaii MN00064 Oregon (OREL MN300001 Idaho MN00064 Pennsylvania 68-00563 Illinois 200011 Puerto Rico MN00064 Indiana C-MN-01 South Carolina 74003001 Iowa 368 Tennessee TN02818 Kansas E-10167 Texas T104704192 Kentucky 90062 Utah (NELAP)MN00064 Louisiana 03086 Virginia 460163 Louisiana MN00064 Washington C486 Maine MN00064 West Virginia #9952C Maryland 322 West Virginia D 382 Michigan 9909 Wisconsin 999407970 Minnesota 027-053-137 Wyoming 8TMS-L Page 3 of 39Report No.....10439456_1668_209_DFR Page 22 of 58 Appendix A Sample Management Pace Analytical Services, Inc.Page 4 of 39Report No.....10439456_1668_209_DFR Page 23 of 58 Page 5 of 39Report No.....10439456_1668_209_DFR Page 24 of 58 7/16/18 Page 6 of 39Report No.....10439456_1668_209_DFR Page 25 of 58 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Report No.....10439456 Reporting Flags A = B = C = D = E = I = J = L = Nn = P = R = S = U = V = X = Y = * = Reporting Limit based on signal to noise Less than 10x higher than method blank level Result obtained from confirmation analysis Result obtained from analysis of diluted sample Exceeds calibration range Interferencepresent Estimated value Suppressive interference,analyte may be biased low Value obtained from additional analysis PCDEInterference Recovery outside target range Peak saturated Analyte not detected Result verified by confirmation analysis %DExceeds limits Calculated using average of daily RFs SeeDiscussion Page 7 of 39Report No.....10439456_1668_209_DFR Page 26 of 58 Appendix B Sample Analysis Summary Pace Analytical Services, Inc.Page 8 of 39Report No.....10439456_1668_209_DFR Page 27 of 58 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Client - PACE Charlotte Client's Sample ID Lab Sample ID Filename Injected ByTotal Amount Extracted% Moisture Dry Weight Extracted ICAL ID CCal Filename(s)Method Blank ID BLANK-63512P180721A_01 P180721A02 NA NA956 mLBAL P180721A_11 92391628001 ABL-SW013-F005 MatrixDilution Collected Received ExtractedAnalyzed 07/21/2018 13:5007/17/2018 13:15 07/13/2018 09:45 07/11/2018 13:25 NAWater Method 1668A Polychlorobiphenyl Sample Analysis Results PCB Isomer RT % Recoveryng's Foundng's AddedIUPACRatio LabeledAnalytes13C-2-MoCB 1 2.75 2.09.587 0.841 4213C-4-MoCB 3 3.12 2.012.439 0.948 4713C-2,2'-DiCB 4 1.61 2.012.738 0.775 3913C-4,4'-DiCB 15 1.56 2.019.890 1.05 5213C-2,2',6-TrCB 19 1.10 2.016.583 0.878 4413C-3,4,4'-TrCB 37 1.02 2.027.724 1.24 6213C-2,2',6,6'-TeCB 54 0.81 2.020.194 0.895 4513C-3,4,4',5-TeCB 81 0.80 2.034.822 1.41 7013C-3,3',4,4'-TeCB 77 0.83 2.035.426 1.40 7013C-2,2',4,6,6'-PeCB 104 1.54 2.026.315 0.918 4613C-2,3,3',4,4'-PeCB 105 1.56 2.039.020 1.35 6713C-2,3,4,4',5-PeCB 114 1.48 2.038.349 1.34 6713C-2,3',4,4',5-PeCB 118 1.60 2.037.779 1.32 6613C-2,3',4,4',5'-PeCB 123 1.53 2.037.444 1.35 6813C-3,3',4,4',5-PeCB 126 1.52 2.042.206 1.40 7013C-2,2',4,4',6,6'-HxCB 155 1.26 2.032.324 0.993 5013C-HxCB(156/157)156/157 1.25 4.045.264 2.59 6513C-2,3',4,4',5,5'-HxCB 167 1.22 2.044.039 1.26 6313C-3,3',4,4',5,5'-HxCB 169 1.28 2.048.567 1.40 7013C-2,2',3,4',5,6,6'-HpCB 188 1.06 2.038.266 1.19 5913C-2,3,3',4,4',5,5'-HpCB 189 1.15 2.051.044 1.36 6813C-2,2',3,3',5,5',6,6'-OcCB 202 0.90 2.043.737 1.19 5913C-2,3,3',4,4',5,5',6-OcCB 205 0.90 2.053.113 1.31 6613C-2,2',3,3',4,4',5,5',6-NoCB 206 0.77 2.054.536 1.28 6413C-2,2',3,3',4,5,5',6,6'-NoCB 208 0.79 2.050.527 1.16 5813C--DeCB 209 0.67 2.056.001 1.24 62 CleanupStandards13C-2,4,4'-TrCB 28 1.08 2.023.297 1.58 7913C-2,3,3',5,5'-PeCB 111 1.54 2.035.393 1.43 7213C-2,2',3,3',5,5',6-HpCB 178 1.11 2.041.385 1.43 71 Recovery Standards13C-2,5-DiCB 9 1.60 2.015.193 NA NA13C-2,2',5,5'-TeCB 52 0.81 2.025.292 NA NA13C-2,2',4,5,5'-PeCB 101 1.57 2.032.592 NA NA13C-2,2',3,4,4',5'-HxCB 138 1.21 2.040.982 NA NA13C-2,2',3,3',4,4',5,5'-OcCB 194 0.90 2.052.725 NA NA Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Page 9 of 39Report No.....10439456_1668_209_DFR Page 28 of 58 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SW013-F005 P180721A_11Lab Sample ID 92391628001 Co-elutions RT ng/L EMLEMPCConcentration ng/LIUPACRatio ng/L 1 ---ND------0.2612---ND------0.2613---ND------0.261 4 ---ND------0.2615---ND------0.2616---ND------0.2617---ND------0.2618---ND------0.261 9 ---ND------0.26110---ND------0.26111---ND------2.56 12 12/13 ---ND------0.5231312/13 ---ND------0.52314---ND------0.261 15 ---ND------0.34516---ND------0.26117---ND------0.2611818/30 ---ND------0.52319---ND------0.2612020/28 ---ND------1.352121/33 ---ND------1.4122---ND------0.994 23 ---ND------0.26124---ND------0.26125---ND------0.261 26 26/29 ---ND------0.52327---ND------0.2612820/28 ---ND------1.35 29 26/29 ---ND------0.5233018/30 ---ND------0.52331---ND------1.3632---ND------0.2613321/33 ---ND------1.41 34 ---ND------0.26135---ND------0.26136---ND------0.261 37 ---ND------0.55438---ND------0.26139---ND------0.261 40 40/41/71 ---ND------1.574140/41/71 ---ND------1.5742---ND------0.5234343/73 ---ND------0.5234444/47/65 ---ND------1.574545/51 ---ND------1.0546---ND------0.5234744/47/65 ---ND------1.57 48 ---ND------0.523 Page 10 of 39Report No.....10439456_1668_209_DFR Page 29 of 58 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SW013-F005 P180721A_11Lab Sample ID 92391628001 Co-elutions RT ng/L EMLEMPCConcentration ng/LIUPACRatio ng/L 49 49/69 0.79 1.0625.846 ---1.055050/53 ---ND------1.055145/51 ---ND------1.05 52 0.75 1.6725.309 ---1.615350/53 ---ND------1.0554---ND------0.52355---ND------0.523560.88 0.59031.519 ---0.523 57 ---ND------0.52358---ND------0.5235959/62/75 ---ND------1.57 60 ---ND------0.5236161/70/74/76 0.77 2.2530.479 ---2.096259/62/75 ---ND------1.57 63 ---ND------0.523640.73 0.77627.774 ---0.5236544/47/65 ---ND------1.57660.74 1.4630.831 ---0.87967---ND------0.52368---ND------0.5236949/69 0.79 (1.06)25.846 ---1.057061/70/74/76 0.77 (2.25)30.479 ---2.09 71 40/41/71 ---ND------1.5772---ND------0.5237343/73 ---ND------0.523 74 61/70/74/76 0.77 (2.25)30.479 ---2.097559/62/75 ---ND------1.577661/70/74/76 0.77 (2.25)30.479 ---2.09 77 ---ND------0.52378---ND------0.52379---ND------0.52380---ND------0.52381---ND------0.523 82 ---ND------0.52383---ND------0.52384---ND------0.523 85 85/116/117 ---ND------1.578686/87/97/108/119/125 ---ND------3.148786/87/97/108/119/125 ---ND------3.14 88 88/91 ---ND------1.0589---ND------0.5239090/101/113 ---ND------1.579188/91 ---ND------1.0592---ND------0.5239393/98/100/102 ---ND------2.0994---ND------0.52395---ND------0.994 96 ---ND------0.523 Page 11 of 39Report No.....10439456_1668_209_DFR Page 30 of 58 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SW013-F005 P180721A_11Lab Sample ID 92391628001 Co-elutions RT ng/L EMLEMPCConcentration ng/LIUPACRatio ng/L 97 86/87/97/108/119/125 ---ND------3.149893/98/100/102 ---ND------2.09991.59 0.65533.213 ---0.523 100 93/98/100/102 ---ND------2.0910190/101/113 ---ND------1.5710293/98/100/102 ---ND------2.09103---ND------0.523104---ND------0.523 105 1.70 0.58839.037 ---0.523106---ND------0.523107107/124 ---ND------1.05 108 86/87/97/108/119/125 ---ND------3.14109---ND------0.523110110/115 1.57 1.4034.688 ---1.05 111 ---ND------0.523112---ND------0.52311390/101/113 ---ND------1.57114---ND------0.523115110/115 1.57 (1.40)34.688 ---1.0511685/116/117 ---ND------1.5711785/116/117 ---ND------1.571181.52 1.0437.796 ---0.669 119 86/87/97/108/119/125 ---ND------3.14120---ND------0.523121---ND------0.523 122 ---ND------0.523123---ND------0.523124107/124 ---ND------1.05 125 86/87/97/108/119/125 ---ND------3.14126---ND------0.523127---ND------0.523128128/166 ---ND------1.05129129/138/163 ---ND------1.57 130 ---ND------0.523131---ND------0.523132---ND------0.523 133 ---ND------0.523134134/143 ---ND------1.05135135/151 ---ND------1.05 136 ---ND------0.523137---ND------0.523138129/138/163 ---ND------1.57139139/140 ---ND------1.05140139/140 ---ND------1.05141---ND------0.523142---ND------0.523143134/143 ---ND------1.05 144 ---ND------0.523 Page 12 of 39Report No.....10439456_1668_209_DFR Page 31 of 58 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SW013-F005 P180721A_11Lab Sample ID 92391628001 Co-elutions RT ng/L EMLEMPCConcentration ng/LIUPACRatio ng/L 145 ---ND------0.523146---ND------0.523147147/149 ---ND------1.05 148 ---ND------0.523149147/149 ---ND------1.05150---ND------0.523151135/151 ---ND------1.05152---ND------0.523 153 153/168 1.23 1.3139.691 ---1.05154---ND------0.523155---ND------0.523 156 156/157 ---ND------1.05157156/157 ---ND------1.05158---ND------0.523 159 ---ND------0.523160---ND------0.523161---ND------0.523162---ND------0.523163129/138/163 ---ND------1.57164---ND------0.523165---ND------0.523166128/166 ---ND------1.05 167 ---ND------0.523168153/168 1.23 (1.31)39.691 ---1.05169---ND------0.523 170 ---ND------0.523171171/173 ---ND------1.05172---ND------0.523 173 171/173 ---ND------1.051741.07 0.56943.235 ---0.523175---ND------0.523176---ND------0.523177---ND------0.523 178 ---ND------0.523179---ND------0.523180180/193 1.08 1.1746.639 ---1.05 181 ---ND------0.523182---ND------0.523183183/185 ---ND------1.05 184 ---ND------0.523185183/185 ---ND------1.05186---ND------0.5231871.04 0.69442.357 ---0.523188---ND------0.523189---ND------0.523190---ND------0.523191---ND------0.523 192 ---ND------0.523 Page 13 of 39Report No.....10439456_1668_209_DFR Page 32 of 58 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SW013-F005 P180721A_11Lab Sample ID 92391628001 Co-elutions RT ng/L EMLEMPCConcentration ng/LIUPACRatio ng/L 193 180/193 1.08 (1.17)46.639 ---1.05194---ND------0.784195---ND------0.784 196 ---ND------0.784197197/200 ---ND------1.57198198/199 ---ND------1.57199198/199 ---ND------1.57200197/200 ---ND------1.57 201 ---ND------0.784202---ND------0.784203---ND------0.784 204 ---ND------0.784205---ND------0.784206---ND------0.784 207 ---ND------0.784208---ND------0.784209---ND------0.784 Page 14 of 39Report No.....10439456_1668_209_DFR Page 33 of 58 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SW013-F005 P180721A_11 Sample Analysis Results Lab Sample ID 92391628001 Congener Group Concentration ng/L Total MonochloroBiphenyls ND TotalDichloroBiphenyls ND Total TrichloroBiphenyls ND Total TetrachloroBiphenyls 7.80 TotalPentachloroBiphenyls 3.69 TotalHexachloroBiphenyls 1.31 TotalHeptachloroBiphenyls 2.43 Total Octachloro Biphenyls ND TotalNonachloroBiphenyls ND DecachloroBiphenyls ND Total PCBs 15.2 ND = Not Detected Page 15 of 39Report No.....10439456_1668_209_DFR Page 34 of 58 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Client - PACE Charlotte Client's Sample ID Lab Sample ID Filename Injected ByTotal Amount Extracted% Moisture Dry Weight Extracted ICAL ID CCal Filename(s)Method Blank ID BLANK-63512P180721A_01 P180721A02 NA NA935 mLBAL P180721A_12 92391628002 ABL-SW014-F005 MatrixDilution Collected Received ExtractedAnalyzed 07/21/2018 14:5007/17/2018 13:15 07/13/2018 09:45 07/11/2018 12:50 NAWater Method 1668A Polychlorobiphenyl Sample Analysis Results PCB Isomer RT % Recoveryng's Foundng's AddedIUPACRatio LabeledAnalytes13C-2-MoCB 1 2.96 2.09.611 0.946 4713C-4-MoCB 3 3.21 2.012.451 1.14 5713C-2,2'-DiCB 4 1.43 2.012.751 0.961 4813C-4,4'-DiCB 15 1.62 2.019.902 1.29 6413C-2,2',6-TrCB 19 1.08 2.016.583 1.15 5713C-3,4,4'-TrCB 37 1.04 2.027.723 1.49 7413C-2,2',6,6'-TeCB 54 0.79 2.020.228 1.08 5413C-3,4,4',5-TeCB 81 0.79 2.034.839 1.64 8213C-3,3',4,4'-TeCB 77 0.83 2.035.442 1.66 8313C-2,2',4,6,6'-PeCB 104 1.56 2.026.315 1.13 5713C-2,3,3',4,4'-PeCB 105 1.52 2.039.036 1.68 8413C-2,3,4,4',5-PeCB 114 1.66 2.038.348 1.63 8113C-2,3',4,4',5-PeCB 118 1.56 2.037.795 1.65 8213C-2,3',4,4',5'-PeCB 123 1.63 2.037.460 1.64 8213C-3,3',4,4',5-PeCB 126 1.53 2.042.205 1.76 8813C-2,2',4,4',6,6'-HxCB 155 1.33 2.032.340 1.26 6313C-HxCB(156/157)156/157 1.22 4.045.263 3.14 7913C-2,3',4,4',5,5'-HxCB 167 1.29 2.044.072 1.53 7713C-3,3',4,4',5,5'-HxCB 169 1.26 2.048.549 1.75 8813C-2,2',3,4',5,6,6'-HpCB 188 1.04 2.038.264 1.45 7213C-2,3,3',4,4',5,5'-HpCB 189 1.01 2.051.065 1.67 8413C-2,2',3,3',5,5',6,6'-OcCB 202 0.91 2.043.753 1.47 7313C-2,3,3',4,4',5,5',6-OcCB 205 0.85 2.053.112 1.60 8013C-2,2',3,3',4,4',5,5',6-NoCB 206 0.78 2.054.556 1.51 7613C-2,2',3,3',4,5,5',6,6'-NoCB 208 0.81 2.050.526 1.43 7213C--DeCB 209 0.72 2.056.022 1.48 74 CleanupStandards13C-2,4,4'-TrCB 28 1.10 2.023.297 1.83 9213C-2,3,3',5,5'-PeCB 111 1.54 2.035.392 1.66 8313C-2,2',3,3',5,5',6-HpCB 178 1.09 2.041.400 1.64 82 Recovery Standards13C-2,5-DiCB 9 1.53 2.015.205 NA NA13C-2,2',5,5'-TeCB 52 0.82 2.025.292 NA NA13C-2,2',4,5,5'-PeCB 101 1.61 2.032.608 NA NA13C-2,2',3,4,4',5'-HxCB 138 1.30 2.040.981 NA NA13C-2,2',3,3',4,4',5,5'-OcCB 194 0.89 2.052.746 NA NA Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Page 16 of 39Report No.....10439456_1668_209_DFR Page 35 of 58 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SW014-F005 P180721A_12Lab Sample ID 92391628002 Co-elutions RT ng/L EMLEMPCConcentration ng/LIUPACRatio ng/L 1 ---ND------0.2672---ND------0.2673---ND------0.267 4 ---ND------0.2675---ND------0.2676---ND------0.2677---ND------0.2678---ND------0.267 9 ---ND------0.26710---ND------0.26711---ND------2.62 12 12/13 ---ND------0.5351312/13 ---ND------0.53514---ND------0.267 15 ---ND------0.35316---ND------0.26717---ND------0.2671818/30 ---ND------0.53519---ND------0.2672020/28 ---ND------1.382121/33 ---ND------1.4422---ND------1.02 23 ---ND------0.26724---ND------0.26725---ND------0.267 26 26/29 ---ND------0.53527---ND------0.2672820/28 ---ND------1.38 29 26/29 ---ND------0.5353018/30 ---ND------0.53531---ND------1.3932---ND------0.2673321/33 ---ND------1.44 34 ---ND------0.26735---ND------0.26736---ND------0.267 37 ---ND------0.56738---ND------0.26739---ND------0.267 40 40/41/71 ---ND------1.604140/41/71 ---ND------1.6042---ND------0.5354343/73 ---ND------0.5354444/47/65 ---ND------1.604545/51 ---ND------1.0746---ND------0.5354744/47/65 ---ND------1.60 48 ---ND------0.535 Page 17 of 39Report No.....10439456_1668_209_DFR Page 36 of 58 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SW014-F005 P180721A_12Lab Sample ID 92391628002 Co-elutions RT ng/L EMLEMPCConcentration ng/LIUPACRatio ng/L 49 49/69 ---ND------1.075050/53 ---ND------1.075145/51 ---ND------1.07 52 ---ND------1.655350/53 ---ND------1.0754---ND------0.53555---ND------0.53556---ND------0.535 57 ---ND------0.53558---ND------0.5355959/62/75 ---ND------1.60 60 ---ND------0.5356161/70/74/76 ---ND------2.146259/62/75 ---ND------1.60 63 ---ND------0.535640.67 0.76127.757 ---0.5356544/47/65 ---ND------1.60660.80 1.3930.831 ---0.89867---ND------0.53568---ND------0.5356949/69 ---ND------1.077061/70/74/76 ---ND------2.14 71 40/41/71 ---ND------1.6072---ND------0.5357343/73 ---ND------0.535 74 61/70/74/76 ---ND------2.147559/62/75 ---ND------1.607661/70/74/76 ---ND------2.14 77 ---ND------0.53578---ND------0.53579---ND------0.53580---ND------0.53581---ND------0.535 82 ---ND------0.53583---ND------0.53584---ND------0.535 85 85/116/117 ---ND------1.608686/87/97/108/119/125 ---ND------3.218786/87/97/108/119/125 ---ND------3.21 88 88/91 ---ND------1.0789---ND------0.5359090/101/113 ---ND------1.609188/91 ---ND------1.0792---ND------0.5359393/98/100/102 ---ND------2.1494---ND------0.53595---ND------1.02 96 ---ND------0.535 Page 18 of 39Report No.....10439456_1668_209_DFR Page 37 of 58 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SW014-F005 P180721A_12Lab Sample ID 92391628002 Co-elutions RT ng/L EMLEMPCConcentration ng/LIUPACRatio ng/L 97 86/87/97/108/119/125 ---ND------3.219893/98/100/102 ---ND------2.14991.60 0.63933.229 ---0.535 100 93/98/100/102 ---ND------2.1410190/101/113 ---ND------1.6010293/98/100/102 ---ND------2.14103---ND------0.535104---ND------0.535 105 ---ND------0.535106---ND------0.535107107/124 ---ND------1.07 108 86/87/97/108/119/125 ---ND------3.21109---ND------0.535110110/115 1.65 1.1934.721 ---1.07 111 ---ND------0.535112---ND------0.53511390/101/113 ---ND------1.60114---ND------0.535115110/115 1.65 (1.19)34.721 ---1.0711685/116/117 ---ND------1.6011785/116/117 ---ND------1.601181.47 0.86437.812 ---0.685 119 86/87/97/108/119/125 ---ND------3.21120---ND------0.535121---ND------0.535 122 ---ND------0.535123---ND------0.535124107/124 ---ND------1.07 125 86/87/97/108/119/125 ---ND------3.21126---ND------0.535127---ND------0.535128128/166 ---ND------1.07129129/138/163 ---ND------1.60 130 ---ND------0.535131---ND------0.535132---ND------0.535 133 ---ND------0.535134134/143 ---ND------1.07135135/151 ---ND------1.07 136 ---ND------0.535137---ND------0.535138129/138/163 ---ND------1.60139139/140 ---ND------1.07140139/140 ---ND------1.07141---ND------0.535142---ND------0.535143134/143 ---ND------1.07 144 ---ND------0.535 Page 19 of 39Report No.....10439456_1668_209_DFR Page 38 of 58 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SW014-F005 P180721A_12Lab Sample ID 92391628002 Co-elutions RT ng/L EMLEMPCConcentration ng/LIUPACRatio ng/L 145 ---ND------0.535146---ND------0.535147147/149 1.17 1.1736.604 ---1.07 148 ---ND------0.535149147/149 1.17 (1.17)36.604 ---1.07150---ND------0.535151135/151 ---ND------1.07152---ND------0.535 153 153/168 1.24 1.4039.707 ---1.07154---ND------0.535155---ND------0.535 156 156/157 ---ND------1.07157156/157 ---ND------1.07158---ND------0.535 159 ---ND------0.535160---ND------0.535161---ND------0.535162---ND------0.535163129/138/163 ---ND------1.60164---ND------0.535165---ND------0.535166128/166 ---ND------1.07 167 ---ND------0.535168153/168 1.24 (1.40)39.707 ---1.07169---ND------0.535 170 ---ND------0.535171171/173 ---ND------1.07172---ND------0.535 173 171/173 ---ND------1.071741.09 0.64843.233 ---0.535175---ND------0.535176---ND------0.535177---ND------0.535 178 ---ND------0.535179---ND------0.535180180/193 1.07 1.3346.638 ---1.07 181 ---ND------0.535182---ND------0.535183183/185 ---ND------1.07 184 ---ND------0.535185183/185 ---ND------1.07186---ND------0.5351871.04 0.80642.339 ---0.535188---ND------0.535189---ND------0.535190---ND------0.535191---ND------0.535 192 ---ND------0.535 Page 20 of 39Report No.....10439456_1668_209_DFR Page 39 of 58 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SW014-F005 P180721A_12Lab Sample ID 92391628002 Co-elutions RT ng/L EMLEMPCConcentration ng/LIUPACRatio ng/L 193 180/193 1.07 (1.33)46.638 ---1.07194---ND------0.802195---ND------0.802 196 ---ND------0.802197197/200 ---ND------1.60198198/199 ---ND------1.60199198/199 ---ND------1.60200197/200 ---ND------1.60 201 ---ND------0.802202---ND------0.802203---ND------0.802 204 ---ND------0.802205---ND------0.802206---ND------0.802 207 ---ND------0.802208---ND------0.802209---ND------0.802 Page 21 of 39Report No.....10439456_1668_209_DFR Page 40 of 58 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SW014-F005 P180721A_12 Sample Analysis Results Lab Sample ID 92391628002 Congener Group Concentration ng/L Total MonochloroBiphenyls ND TotalDichloroBiphenyls ND Total TrichloroBiphenyls ND Total TetrachloroBiphenyls 2.15 TotalPentachloroBiphenyls 2.70 TotalHexachloroBiphenyls 2.57 TotalHeptachloroBiphenyls 2.79 Total Octachloro Biphenyls ND TotalNonachloroBiphenyls ND DecachloroBiphenyls ND Total PCBs 10.2 ND = Not Detected Page 22 of 39Report No.....10439456_1668_209_DFR Page 41 of 58 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Client - PACE Charlotte Client's Sample ID Lab Sample ID Filename Injected ByTotal Amount Extracted% Moisture Dry Weight Extracted ICAL ID CCal Filename(s)Method Blank ID BLANK-63512P180721A_01 P180721A02 NA NA965 mLBAL P180721A_13 92391628003 ABL-SW015-F005 MatrixDilution Collected Received ExtractedAnalyzed 07/21/2018 15:4907/17/2018 13:15 07/13/2018 09:45 07/11/2018 12:20 NAWater Method 1668A Polychlorobiphenyl Sample Analysis Results PCB Isomer RT % Recoveryng's Foundng's AddedIUPACRatio LabeledAnalytes13C-2-MoCB 1 2.99 2.09.599 0.892 4513C-4-MoCB 3 2.95 2.012.427 1.04 5213C-2,2'-DiCB 4 1.66 2.012.739 0.910 4513C-4,4'-DiCB 15 1.51 2.019.890 1.31 6513C-2,2',6-TrCB 19 1.04 2.016.571 1.08 5413C-3,4,4'-TrCB 37 1.10 2.027.708 1.64 8213C-2,2',6,6'-TeCB 54 0.75 2.020.195 1.12 5613C-3,4,4',5-TeCB 81 0.81 2.034.824 1.62 8113C-3,3',4,4'-TeCB 77 0.80 2.035.428 1.62 8113C-2,2',4,6,6'-PeCB 104 1.52 2.026.316 1.34 6713C-2,3,3',4,4'-PeCB 105 1.57 2.039.022 1.75 8813C-2,3,4,4',5-PeCB 114 1.58 2.038.335 1.69 8513C-2,3',4,4',5-PeCB 118 1.67 2.037.781 1.75 8713C-2,3',4,4',5'-PeCB 123 1.60 2.037.446 1.68 8413C-3,3',4,4',5-PeCB 126 1.55 2.042.192 1.86 9313C-2,2',4,4',6,6'-HxCB 155 1.27 2.032.326 1.38 6913C-HxCB(156/157)156/157 1.22 4.045.233 3.13 7813C-2,3',4,4',5,5'-HxCB 167 1.31 2.044.042 1.63 8213C-3,3',4,4',5,5'-HxCB 169 1.25 2.048.537 1.85 9313C-2,2',3,4',5,6,6'-HpCB 188 1.07 2.038.251 1.48 7413C-2,3,3',4,4',5,5'-HpCB 189 1.03 2.051.048 1.74 8713C-2,2',3,3',5,5',6,6'-OcCB 202 0.93 2.043.740 1.47 7413C-2,3,3',4,4',5,5',6-OcCB 205 0.96 2.053.117 1.67 8413C-2,2',3,3',4,4',5,5',6-NoCB 206 0.79 2.054.540 1.64 8213C-2,2',3,3',4,5,5',6,6'-NoCB 208 0.82 2.050.509 1.48 7413C--DeCB 209 0.71 2.056.006 1.63 81 CleanupStandards13C-2,4,4'-TrCB 28 0.99 2.023.298 1.77 8813C-2,3,3',5,5'-PeCB 111 1.58 2.035.378 1.64 8213C-2,2',3,3',5,5',6-HpCB 178 1.10 2.041.404 1.57 78 Recovery Standards13C-2,5-DiCB 9 1.56 2.015.193 NA NA13C-2,2',5,5'-TeCB 52 0.79 2.025.294 NA NA13C-2,2',4,5,5'-PeCB 101 1.55 2.032.594 NA NA13C-2,2',3,4,4',5'-HxCB 138 1.24 2.040.968 NA NA13C-2,2',3,3',4,4',5,5'-OcCB 194 0.92 2.052.729 NA NA Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Page 23 of 39Report No.....10439456_1668_209_DFR Page 42 of 58 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SW015-F005 P180721A_13Lab Sample ID 92391628003 Co-elutions RT ng/L EMLEMPCConcentration ng/LIUPACRatio ng/L 1 ---ND------0.2592---ND------0.2593---ND------0.259 4 ---ND------0.2595---ND------0.2596---ND------0.2597---ND------0.2598---ND------0.259 9 ---ND------0.25910---ND------0.25911---ND------2.54 12 12/13 ---ND------0.5181312/13 ---ND------0.51814---ND------0.259 15 ---ND------0.34216---ND------0.25917---ND------0.2591818/30 ---ND------0.51819---ND------0.2592020/28 ---ND------1.342121/33 ---ND------1.4022---ND------0.985 23 ---ND------0.25924---ND------0.25925---ND------0.259 26 26/29 ---ND------0.51827---ND------0.2592820/28 ---ND------1.34 29 26/29 ---ND------0.5183018/30 ---ND------0.51831---ND------1.3532---ND------0.2593321/33 ---ND------1.40 34 ---ND------0.25935---ND------0.25936---ND------0.259 37 ---ND------0.54938---ND------0.25939---ND------0.259 40 40/41/71 ---ND------1.554140/41/71 ---ND------1.5542---ND------0.5184343/73 ---ND------0.5184444/47/65 ---ND------1.554545/51 ---ND------1.0446---ND------0.5184744/47/65 ---ND------1.55 48 ---ND------0.518 Page 24 of 39Report No.....10439456_1668_209_DFR Page 43 of 58 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SW015-F005 P180721A_13Lab Sample ID 92391628003 Co-elutions RT ng/L EMLEMPCConcentration ng/LIUPACRatio ng/L 49 49/69 ---ND------1.045050/53 ---ND------1.045145/51 ---ND------1.04 52 ---ND------1.605350/53 ---ND------1.0454---ND------0.51855---ND------0.51856---ND------0.518 57 ---ND------0.51858---ND------0.5185959/62/75 ---ND------1.55 60 ---ND------0.5186161/70/74/76 ---ND------2.076259/62/75 ---ND------1.55 63 ---ND------0.518640.79 0.60327.742 ---0.5186544/47/65 ---ND------1.55660.79 1.0830.833 ---0.87167---ND------0.51868---ND------0.5186949/69 ---ND------1.047061/70/74/76 ---ND------2.07 71 40/41/71 ---ND------1.5572---ND------0.5187343/73 ---ND------0.518 74 61/70/74/76 ---ND------2.077559/62/75 ---ND------1.557661/70/74/76 ---ND------2.07 77 ---ND------0.51878---ND------0.51879---ND------0.51880---ND------0.51881---ND------0.518 82 ---ND------0.51883---ND------0.51884---ND------0.518 85 85/116/117 ---ND------1.558686/87/97/108/119/125 ---ND------3.118786/87/97/108/119/125 ---ND------3.11 88 88/91 ---ND------1.0489---ND------0.5189090/101/113 ---ND------1.559188/91 ---ND------1.0492---ND------0.5189393/98/100/102 ---ND------2.0794---ND------0.51895---ND------0.985 96 ---ND------0.518 Page 25 of 39Report No.....10439456_1668_209_DFR Page 44 of 58 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SW015-F005 P180721A_13Lab Sample ID 92391628003 Co-elutions RT ng/L EMLEMPCConcentration ng/LIUPACRatio ng/L 97 86/87/97/108/119/125 ---ND------3.119893/98/100/102 ---ND------2.0799---ND------0.518 100 93/98/100/102 ---ND------2.0710190/101/113 ---ND------1.5510293/98/100/102 ---ND------2.07103---ND------0.518104---ND------0.518 105 ---ND------0.518106---ND------0.518107107/124 ---ND------1.04 108 86/87/97/108/119/125 ---ND------3.11109---ND------0.518110110/115 ---ND------1.04 111 ---ND------0.518112---ND------0.51811390/101/113 ---ND------1.55114---ND------0.518115110/115 ---ND------1.0411685/116/117 ---ND------1.5511785/116/117 ---ND------1.55118---ND------0.663 119 86/87/97/108/119/125 ---ND------3.11120---ND------0.518121---ND------0.518 122 ---ND------0.518123---ND------0.518124107/124 ---ND------1.04 125 86/87/97/108/119/125 ---ND------3.11126---ND------0.518127---ND------0.518128128/166 ---ND------1.04129129/138/163 ---ND------1.55 130 ---ND------0.518131---ND------0.518132---ND------0.518 133 ---ND------0.518134134/143 ---ND------1.04135135/151 ---ND------1.04 136 ---ND------0.518137---ND------0.518138129/138/163 ---ND------1.55139139/140 ---ND------1.04140139/140 ---ND------1.04141---ND------0.518142---ND------0.518143134/143 ---ND------1.04 144 ---ND------0.518 Page 26 of 39Report No.....10439456_1668_209_DFR Page 45 of 58 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SW015-F005 P180721A_13Lab Sample ID 92391628003 Co-elutions RT ng/L EMLEMPCConcentration ng/LIUPACRatio ng/L 145 ---ND------0.518146---ND------0.518147147/149 ---ND------1.04 148 ---ND------0.518149147/149 ---ND------1.04150---ND------0.518151135/151 ---ND------1.04152---ND------0.518 153 153/168 ---ND------1.04154---ND------0.518155---ND------0.518 156 156/157 ---ND------1.04157156/157 ---ND------1.04158---ND------0.518 159 ---ND------0.518160---ND------0.518161---ND------0.518162---ND------0.518163129/138/163 ---ND------1.55164---ND------0.518165---ND------0.518166128/166 ---ND------1.04 167 ---ND------0.518168153/168 ---ND------1.04169---ND------0.518 170 ---ND------0.518171171/173 ---ND------1.04172---ND------0.518 173 171/173 ---ND------1.04174---ND------0.518175---ND------0.518176---ND------0.518177---ND------0.518 178 ---ND------0.518179---ND------0.518180180/193 ---ND------1.04 181 ---ND------0.518182---ND------0.518183183/185 ---ND------1.04 184 ---ND------0.518185183/185 ---ND------1.04186---ND------0.5181871.09 0.52642.343 ---0.518188---ND------0.518189---ND------0.518190---ND------0.518191---ND------0.518 192 ---ND------0.518 Page 27 of 39Report No.....10439456_1668_209_DFR Page 46 of 58 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Sample Analysis Results Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SW015-F005 P180721A_13Lab Sample ID 92391628003 Co-elutions RT ng/L EMLEMPCConcentration ng/LIUPACRatio ng/L 193 180/193 ---ND------1.04194---ND------0.777195---ND------0.777 196 ---ND------0.777197197/200 ---ND------1.55198198/199 ---ND------1.55199198/199 ---ND------1.55200197/200 ---ND------1.55 201 ---ND------0.777202---ND------0.777203---ND------0.777 204 ---ND------0.777205---ND------0.777206---ND------0.777 207 ---ND------0.777208---ND------0.777209---ND------0.777 Page 28 of 39Report No.....10439456_1668_209_DFR Page 47 of 58 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Method 1668A Polychlorobiphenyl Client Sample ID Filename ABL-SW015-F005 P180721A_13 Sample Analysis Results Lab Sample ID 92391628003 Congener Group Concentration ng/L Total MonochloroBiphenyls ND TotalDichloroBiphenyls ND Total TrichloroBiphenyls ND Total TetrachloroBiphenyls 1.68 TotalPentachloroBiphenyls ND TotalHexachloroBiphenyls ND TotalHeptachloroBiphenyls 0.526 Total Octachloro Biphenyls ND TotalNonachloroBiphenyls ND DecachloroBiphenyls ND Total PCBs 2.20 ND = Not Detected Page 29 of 39Report No.....10439456_1668_209_DFR Page 48 of 58 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Method 1668A Polychlorobiphenyl Lab Sample ID Injected ByFilename Total Amount Extracted ICAL ID CCal Filename(s) BLANK-63512 P180721B_06BAL1040 mL P180721B02 P180721B_01 MatrixExtracted Analyzed Water (QC Matrix)07/17/2018 13:15 07/21/2018 22:54 Blank Analysis Results Dilution NA PCB Isomer RT % Recoveryng's Foundng's AddedIUPACRatio Labeled Analytes13C-2-MoCB 1 2.94 2.09.599 1.30 6513C-4-MoCB 3 2.84 2.012.439 1.42 7113C-2,2'-DiCB 4 1.54 2.012.738 1.28 6413C-4,4'-DiCB 15 1.52 2.019.890 1.48 7413C-2,2',6-TrCB 19 0.96 2.016.559 1.91 9613C-3,4,4'-TrCB 37 1.17 2.027.710 1.92 9613C-2,2',6,6'-TeCB 54 0.89 2.020.197 1.45 73 13C-3,4,4',5-TeCB 81 0.84 2.034.825 1.81 9013C-3,3',4,4'-TeCB 77 0.85 2.035.429 1.79 9013C-2,2',4,6,6'-PeCB 104 1.52 2.026.318 1.28 6413C-2,3,3',4,4'-PeCB 105 1.60 2.039.006 1.88 9413C-2,3,4,4',5-PeCB 114 1.64 2.038.335 1.78 8913C-2,3',4,4',5-PeCB 118 1.51 2.037.782 1.85 9213C-2,3',4,4',5'-PeCB 123 1.49 2.037.446 1.85 9313C-3,3',4,4',5-PeCB 126 1.59 2.042.192 1.97 9913C-2,2',4,4',6,6'-HxCB 155 1.27 2.032.327 1.27 6413C-HxCB (156/157)156/157 1.31 4.045.250 3.34 8413C-2,3',4,4',5,5'-HxCB 167 1.28 2.044.042 1.68 8413C-3,3',4,4',5,5'-HxCB 169 1.29 2.048.536 1.86 9313C-2,2',3,4',5,6,6'-HpCB 188 1.02 2.038.251 1.47 7413C-2,3,3',4,4',5,5'-HpCB 189 1.07 2.051.047 1.80 9013C-2,2',3,3',5,5',6,6'-OcCB 202 0.95 2.043.740 1.55 7713C-2,3,3',4,4',5,5',6-OcCB 205 0.89 2.053.116 1.74 8713C-2,2',3,3',4,4',5,5',6-NoCB 206 0.76 2.054.539 1.60 8013C-2,2',3,3',4,5,5',6,6'-NoCB 208 0.84 2.050.508 1.56 7813C--DeCB 209 0.63 2.055.983 1.62 81 Cleanup Standards13C-2,4,4'-TrCB 28 1.15 2.023.283 2.23 11113C-2,3,3',5,5'-PeCB 111 1.61 2.035.396 1.82 9113C-2,2',3,3',5,5',6-HpCB 178 1.05 2.041.387 1.75 87 Recovery Standards13C-2,5-DiCB 9 1.60 2.015.193 NA NA13C-2,2',5,5'-TeCB 52 0.75 2.025.295 NA NA13C-2,2',4,5,5'-PeCB 101 1.62 2.032.595 NA NA13C-2,2',3,4,4',5'-HxCB 138 1.25 2.040.968 NA NA13C-2,2',3,3',4,4',5,5'-OcCB 194 0.94 2.052.728 NA NA Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits Nn =Value obtained from additional analyses ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference ng's = Nanograms Page 30 of 39Report No.....10439456_1668_209_DFR Page 49 of 58 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits ng/L = Nanograms per liter ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference Method 1668A Polychlorobiphenyl Lab Sample ID Filename BLANK-63512 P180721B_06 Blank Analysis Results Co-elutions RT ng/L EMLEMPCConcentration ng/LIUPACRatio ng/L 1 ---ND------0.2412---ND------0.2413---ND------0.2414---ND------0.2415---ND------0.2416---ND------0.2417---ND------0.2418---ND------0.2419---ND------0.24110---ND------0.24111---ND------2.371212/13 ---ND------0.4831312/13 ---ND------0.48314---ND------0.24115---ND------0.24116---ND------0.24117---ND------0.2411818/30 ---ND------0.483 19 ---ND------0.2412020/28 ---ND------1.252121/33 ---ND------1.3022---ND------0.91823---ND------0.24124---ND------0.24125---ND------0.2412626/29 ---ND------0.48327---ND------0.2412820/28 ---ND------1.252926/29 ---ND------0.4833018/30 ---ND------0.48331---ND------1.2632---ND------0.2413321/33 ---ND------1.3034---ND------0.24135---ND------0.24136---ND------0.24137---ND------0.51238---ND------0.24139---ND------0.2414040/41/71 ---ND------1.454140/41/71 ---ND------1.4542---ND------0.4834343/73 ---ND------0.483 44 44/47/65 ---ND------1.454545/51 ---ND------0.966 Page 31 of 39Report No.....10439456_1668_209_DFR Page 50 of 58 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits ng/L = Nanograms per liter ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference Method 1668A Polychlorobiphenyl Lab Sample ID Filename BLANK-63512 P180721B_06 Blank Analysis Results Co-elutions RT ng/L EMLEMPCConcentration ng/LIUPACRatio ng/L 46 ---ND------0.4834744/47/65 ---ND------1.4548---ND------0.4834949/69 ---ND------0.9665050/53 ---ND------0.9665145/51 ---ND------0.96652---ND------1.495350/53 ---ND------0.96654---ND------0.48355---ND------0.48356---ND------0.48357---ND------0.48358---ND------0.4835959/62/75 ---ND------1.4560---ND------0.4836161/70/74/76 ---ND------1.936259/62/75 ---ND------1.4563---ND------0.483 64 ---ND------0.4836544/47/65 ---ND------1.4566---ND------0.81167---ND------0.48368---ND------0.4836949/69 ---ND------0.9667061/70/74/76 ---ND------1.937140/41/71 ---ND------1.4572---ND------0.4837343/73 ---ND------0.4837461/70/74/76 ---ND------1.937559/62/75 ---ND------1.457661/70/74/76 ---ND------1.9377---ND------0.48378---ND------0.48379---ND------0.48380---ND------0.48381---ND------0.48382---ND------0.48383---ND------0.48384---ND------0.4838585/116/117 ---ND------1.458686/87/97/108/119/125 ---ND------2.908786/87/97/108/119/125 ---ND------2.908888/91 ---ND------0.966 89 ---ND------0.4839090/101/113 ---ND------1.45 Page 32 of 39Report No.....10439456_1668_209_DFR Page 51 of 58 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits ng/L = Nanograms per liter ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference Method 1668A Polychlorobiphenyl Lab Sample ID Filename BLANK-63512 P180721B_06 Blank Analysis Results Co-elutions RT ng/L EMLEMPCConcentration ng/LIUPACRatio ng/L 91 88/91 ---ND------0.96692---ND------0.4839393/98/100/102 ---ND------1.9394---ND------0.48395---ND------0.91896---ND------0.4839786/87/97/108/119/125 ---ND------2.909893/98/100/102 ---ND------1.9399---ND------0.48310093/98/100/102 ---ND------1.9310190/101/113 ---ND------1.4510293/98/100/102 ---ND------1.93103---ND------0.483104---ND------0.483105---ND------0.483106---ND------0.483107107/124 ---ND------0.96610886/87/97/108/119/125 ---ND------2.90 109 ---ND------0.483110110/115 ---ND------0.966111---ND------0.483112---ND------0.48311390/101/113 ---ND------1.45114---ND------0.483115110/115 ---ND------0.96611685/116/117 ---ND------1.4511785/116/117 ---ND------1.45118---ND------0.61811986/87/97/108/119/125 ---ND------2.90120---ND------0.483121---ND------0.483122---ND------0.483123---ND------0.483124107/124 ---ND------0.96612586/87/97/108/119/125 ---ND------2.90126---ND------0.483127---ND------0.483128128/166 ---ND------0.966129129/138/163 ---ND------1.45130---ND------0.483131---ND------0.483132---ND------0.483133---ND------0.483 134 134/143 ---ND------0.966135135/151 ---ND------0.966 Page 33 of 39Report No.....10439456_1668_209_DFR Page 52 of 58 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits ng/L = Nanograms per liter ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference Method 1668A Polychlorobiphenyl Lab Sample ID Filename BLANK-63512 P180721B_06 Blank Analysis Results Co-elutions RT ng/L EMLEMPCConcentration ng/LIUPACRatio ng/L 136 ---ND------0.483137---ND------0.483138129/138/163 ---ND------1.45139139/140 ---ND------0.966140139/140 ---ND------0.966141---ND------0.483142---ND------0.483143134/143 ---ND------0.966144---ND------0.483145---ND------0.483146---ND------0.483147147/149 ---ND------0.966148---ND------0.483149147/149 ---ND------0.966150---ND------0.483151135/151 ---ND------0.966152---ND------0.483153153/168 ---ND------0.966 154 ---ND------0.483155---ND------0.483156156/157 ---ND------0.966157156/157 ---ND------0.966158---ND------0.483159---ND------0.483160---ND------0.483161---ND------0.483162---ND------0.483163129/138/163 ---ND------1.45164---ND------0.483165---ND------0.483166128/166 ---ND------0.966167---ND------0.483168153/168 ---ND------0.966169---ND------0.483170---ND------0.483171171/173 ---ND------0.966172---ND------0.483173171/173 ---ND------0.966174---ND------0.483175---ND------0.483176---ND------0.483177---ND------0.483178---ND------0.483 179 ---ND------0.483180180/193 ---ND------0.966 Page 34 of 39Report No.....10439456_1668_209_DFR Page 53 of 58 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Conc =Concentration EML =Method Specified Reporting Limit (1668A) EMPC = Estimated Maximum Possible Concentration A =Limit ofDetection based on signal to noise B = Less than 10 times higher than method blank level R =Recovery outside of Method 1668A control limits ng/L = Nanograms per liter ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion X = Outside QC Limits RT = Retention Time I=Interference Method 1668A Polychlorobiphenyl Lab Sample ID Filename BLANK-63512 P180721B_06 Blank Analysis Results Co-elutions RT ng/L EMLEMPCConcentration ng/LIUPACRatio ng/L 181 ---ND------0.483182---ND------0.483183183/185 ---ND------0.966184---ND------0.483185183/185 ---ND------0.966186---ND------0.483187---ND------0.483188---ND------0.483189---ND------0.483190---ND------0.483191---ND------0.483192---ND------0.483193180/193 ---ND------0.966194---ND------0.724195---ND------0.724196---ND------0.724197197/200 ---ND------1.45198198/199 ---ND------1.45 199 198/199 ---ND------1.45200197/200 ---ND------1.45201---ND------0.724202---ND------0.724203---ND------0.724204---ND------0.724205---ND------0.724206---ND------0.724207---ND------0.724208---ND------0.724209---ND------0.724 Page 35 of 39Report No.....10439456_1668_209_DFR Page 54 of 58 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Method 1668A Polychlorobiphenyl Client Sample ID Filename CBLKSY P180721B_06 Blank Analysis Results Lab Sample ID BLANK-63512 Congener Group Concentration ng/L Total MonochloroBiphenyls ND TotalDichloroBiphenyls ND Total TrichloroBiphenyls ND Total TetrachloroBiphenyls ND TotalPentachloroBiphenyls ND TotalHexachloroBiphenyls ND TotalHeptachloroBiphenyls ND Total Octachloro Biphenyls ND TotalNonachloroBiphenyls ND DecachloroBiphenyls ND Total PCBs ND ND = Not Detected Page 36 of 39Report No.....10439456_1668_209_DFR Page 55 of 58 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Method 1668A Polychlorobiphenyls Lab Sample ID Injected By FilenameTotal Amount Extracted ICAL ID CCal Filename(s) LCS-63513P180721B_03 BAL 945 mL P180721B02 P180721B_01 MatrixDilution Extracted Analyzed Water (QC Matrix) 07/17/2018 13:15 07/21/2018 19:55 NA Method Blank ID BLANK-63512 Laboratory Control Spike Analysis Results PCB Spiked Found Spiked Found % RecoveryIsomer(ng)(ng) % Recovery(ng)(ng) Native Analytes Labeled Analytes 1 1.0 0.996 2.0 0.992 50100 3 1.0 0.978 2.0 1.06 539841.0 1.07 2.0 0.945 47107151.0 1.03 2.0 1.12 56103 19 1.0 0.953 2.0 1.07 5395 37 1.0 0.813 2.0 1.35 6881 54 1.0 0.932 2.0 0.963 4893811.0 0.870 2.0 1.45 7387771.0 0.928 2.0 1.35 6793 104 1.0 0.985 2.0 0.926 4698 105 1.0 0.923 2.0 1.37 6992 114 1.0 1.01 2.0 1.32 661011181.0 0.968 2.0 1.36 68971231.0 0.959 2.0 1.33 6796 126 1.0 0.977 2.0 1.43 7298 155 1.0 0.921 2.0 0.950 4892 156/157 2.0 1.86 4.0 2.54 63931671.0 0.954 2.0 1.24 62951691.0 0.944 2.0 1.43 7194 188 1.0 1.00 2.0 0.960 48100 189 1.0 1.01 2.0 1.30 65101 202 1.0 0.991 2.0 1.00 50992051.0 1.03 2.0 1.20 601032061.0 1.03 2.0 1.13 56103 208 1.0 0.993 2.0 1.06 5399 209 1.0 1.05 2.0 1.08 54105 R =Recovery outside of method 1668A control limits Nn =Result obtained from alternate analysis ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion ng = Nanograms I=Interference Page 37 of 39Report No.....10439456_1668_209_DFR Page 56 of 58 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Method 1668A Polychlorobiphenyls Lab Sample ID Injected By FilenameTotal Amount Extracted ICAL ID CCal Filename(s) LCSD-63514P180721B_04 BAL 959 mL P180721B02 P180721B_01 MatrixDilution Extracted Analyzed Water (QC Matrix) 07/17/2018 13:15 07/21/2018 20:54 NA Method Blank ID BLANK-63512 Laboratory Control Spike Analysis Results PCB Spiked Found Spiked Found % RecoveryIsomer(ng)(ng) % Recovery(ng)(ng) Native Analytes Labeled Analytes 1 1.0 1.04 2.0 1.11 55104 3 1.0 1.04 2.0 1.12 5610441.0 1.13 2.0 0.983 49113151.0 1.09 2.0 1.15 57109 19 1.0 0.903 2.0 1.23 6190 37 1.0 0.939 2.0 1.11 6394 I 54 1.0 0.903 2.0 1.04 5290811.0 0.914 2.0 1.44 7291771.0 0.968 2.0 1.33 6797 104 1.0 0.991 2.0 1.00 5099 105 1.0 1.01 2.0 1.41 71101 114 1.0 1.02 2.0 1.42 711021181.0 0.938 2.0 1.45 73941231.0 0.953 2.0 1.45 7295 126 1.0 0.969 2.0 1.56 7897 155 1.0 1.04 2.0 0.987 49104 156/157 2.0 2.03 4.0 2.67 671021671.0 0.986 2.0 1.36 68991691.0 0.931 2.0 1.49 7493 188 1.0 1.01 2.0 1.13 56101 189 1.0 0.995 2.0 1.51 75100 202 1.0 0.961 2.0 1.19 60962051.0 1.02 2.0 1.33 671022061.0 1.07 2.0 1.26 63107 208 1.0 0.921 2.0 1.27 6392 209 1.0 0.944 2.0 1.20 6094 R =Recovery outside of method 1668A control limits Nn =Result obtained from alternate analysis ND = Not Detected NA = Not Applicable NC = Not Calculated *=See Discussion ng = Nanograms I=Interference Page 38 of 39Report No.....10439456_1668_209_DFR Page 57 of 58 REPORTOF LABORATORY ANALYSIS This report shall notbe reproduced,except in full, withoutthewrittenconsentofPaceAnalyticalServices,Inc. Pace Analytical Services,LLC 1700 Elm Street - Suite 200 Minneapolis, MN 55414 Tel:612-607-1700 Fax:612-607-6444 Client Spike 1 ID Spike 1 Filename P180721B_03 LCS-63513 PACE Charlotte Spike Recovery Relative Percent Difference (RPD) Results Spike 2 ID Spike 2 Filename P180721B_04 LCSD-63514 Method 1668A Spike 1 Spike 2 Compound %REC %REC %RPDIUPAC 2-MoCB 100 104 3.914-MoCB 98 104 5.932,2'-DiCB 107 113 5.544,4'-DiCB 103 109 5.7152,2',6-TrCB 95 90 5.4193,4,4'-TrCB 81 94 14.9372,2',6,6'-TeCB 93 90 3.3543,3',4,4'-TeCB 93 97 4.2773,4,4',5-TeCB 87 91 4.5812,2',4,6,6'-PeCB 98 99 1.01042,3,3',4,4'-PeCB 92 101 9.31052,3,4,4',5-PeCB 101 102 1.01142,3',4,4',5-PeCB 97 94 3.11182,3',4,4',5'-PeCB 96 95 1.01233,3',4,4',5-PeCB 98 97 1.01262,2',4,4',6,6'-HxCB 92 104 12.2155(156/157)93 102 9.2156/1572,3',4,4',5,5'-HxCB 95 99 4.11673,3',4,4',5,5'-HxCB 94 93 1.11692,2',3,4',5,6,6'-HpCB 100 101 1.01882,3,3',4,4',5,5'-HpCB 101 100 1.01892,2',3,3',5,5',6,6'-OcCB 99 96 3.12022,3,3',4,4',5,5',6-OcCB 103 102 1.0205 2,2',3,3',4,4',5,5',6-NoCB 103 107 3.82062,2',3,3',4,5,5',6,6'-NoCB 99 92 7.3208Decachlorobiphenyl1059411.1209 %REC =Percent Recovered RPD =The difference between the two values dividedby the meanvalue Page 39 of 39Report No.....10439456_1668_209_DFR Page 58 of 58