Loading...
HomeMy WebLinkAbout8106_Duke_Rogers_CQAPart2_DIN25924_20160323.pdfMORGAN CORPProject Name:InspTotalSizeMaterialDatePipe IDDS MHUS MH StreetCC2CC33/8/2016 DUKE POWER RD Other 306.810 306.8 Pipe Size:10 306.8 306.8Total Ln.:Inspected Ln.: InspTotalSizeMaterialDatePipe IDDS MHUS MH StreetCC2CC2A13/9/2016 DUKE POWER RD Other 828.818 828.8CC3CC3A23/9/2016 DUKE POWER RD Other 709.118 709.1CC4CC4A33/9/2016 DUKE POWER RD Other 586.618 586.6 Pipe Size:18 2124.5 2124.5Total Ln.:Inspected Ln.: 2431.32431.3Project Total Ln.:Project Inspected Ln.: Project Summary Bio-Nomic Services516 Rountree Road Charlotte NC 28217(704) 529-0000 Page #:1MORGAN CORP CC3 Access Point Tee Connection0.0 ft. Water Level0.0 ft.2 General Observation9.4 ft.Make shift bridge to cross Tconnection General Observation15.3 ft.GATE VALVE General Observation68.3 ft.SWEEP #HC3 Water Level306.3 ft.2 Access Point Tee Connection306.8 ft.CC3 CC2 Plot Bio-Nomic Services516 Rountree Road Charlotte NC 28217(704) 529-0000 Pipe Joint...Width DUKE POWER RD OtherCharlotte Other CC3 306.8 N/A 10 Circular MaterialGM #Location C...City DS Manhole Length surveyed HeightYear Renewed Year Laid Shape Street OtherSewer Use CC2Upstream MH 306.8Total Length Location Details 10 Pre-Acceptance 16:43 16:00 DryNo Pre-Cleaning 20160308OPRDirection PO NumberSPR QSR MPR QMR SPRI MPRI Time WeatherOPRI Purpose Pre-Cleaning Date Work Order Surveyed By Date Cleaned End Time Customer UpstreamBIO--NOMIC_HEMPHILL Additional Info Page #:2MORGAN CORP 0.0 ft.Distance: Access Point Tee ConnectionCondition: 0Grade: N/ARemarks: 0.0 ft.Distance: Water LevelCondition: 2Grade: N/ARemarks: 9.4 ft.Distance: General ObservationCondition: 0Grade: Make shift bridge to cross T connectionRemarks: 15.3 ft.Distance: General ObservationCondition: 0Grade: GATE VALVERemarks: Pic Report 4/Page Bio-Nomic Services516 Rountree Road Charlotte NC 28217(704) 529-0000 Pipe Joint...Width DUKE POWER RD OtherCharlotte Other CC3 306.8 N/A 10 Circular MaterialGM #Location C...City DS Manhole Length surveyed HeightYear Renewed Year Laid Shape Street OtherSewer Use CC2Upstream MH 306.8Total Length Location Details 10 Page #:3MORGAN CORP 68.3 ft.Distance: General ObservationCondition: 0Grade: SWEEP #HC3Remarks: 306.3 ft.Distance: Water LevelCondition: 2Grade: N/ARemarks: 306.8 ft.Distance: Access Point Tee ConnectionCondition: 0Grade: CC3Remarks: Pic Report 4/Page Bio-Nomic Services516 Rountree Road Charlotte NC 28217(704) 529-0000 Pipe Joint...Width DUKE POWER RD OtherCharlotte Other CC3 306.8 N/A 10 Circular MaterialGM #Location C...City DS Manhole Length surveyed HeightYear Renewed Year Laid Shape Street OtherSewer Use CC2Upstream MH 306.8Total Length Location Details 10 Page #:4MORGAN CORP CC3 Access Point Cleanout Mainline0.0 ft.ACCESS VIA LECHAE SYSTEM Water Level0.0 ft.2 Water Level, Sag in pipe189.9 ft.2 Access Point Tee Connection200.1 ft. Access Point Tee Connection200.1 ft. Shape or Size Change205.8 ft. Water Level, Sag in pipe331.5 ft.2 Access Point End of Pipe709.1 ft.CAPPED CC3A Plot Bio-Nomic Services516 Rountree Road Charlotte NC 28217(704) 529-0000 Pipe Joint...Width DUKE POWER RD OtherCharlotte Other CC3A 709.1 2 18 Circular MaterialGM #Location C...City DS Manhole Length surveyed HeightYear Renewed Year Laid Shape Street OtherSewer Use CC3Upstream MH 709.1Total Length Location Details 18 Pre-Acceptance 14:18 13:28 Very DryNo Pre-Cleaning 20160309OPRDirection PO NumberSPR QSR MPR QMR SPRI MPRI Time WeatherOPRI Purpose Pre-Cleaning Date Work Order Surveyed By Date Cleaned End Time Customer DownstreamBIO--NOMIC_HEMPHILL Additional Info Page #:5MORGAN CORP 0.0 ft.Distance: Access Point Cleanout MainlineCondition: 0Grade: ACCESS VIA LECHAE SYSTEMRemarks: 0.0 ft.Distance: Water LevelCondition: 2Grade: N/ARemarks: 189.9 ft.Distance: Water Level, Sag in pipeCondition: 2Grade: N/ARemarks: 200.1 ft.Distance: Access Point Tee ConnectionCondition: 0Grade: N/ARemarks: Pic Report 4/Page Bio-Nomic Services516 Rountree Road Charlotte NC 28217(704) 529-0000 Pipe Joint...Width DUKE POWER RD OtherCharlotte Other CC3A 709.1 2 18 Circular MaterialGM #Location C...City DS Manhole Length surveyed HeightYear Renewed Year Laid Shape Street OtherSewer Use CC3Upstream MH 709.1Total Length Location Details 18 Page #:6MORGAN CORP 200.1 ft.Distance: Access Point Tee ConnectionCondition: 0Grade: N/ARemarks: 205.8 ft.Distance: Shape or Size ChangeCondition: 0Grade: N/ARemarks: 331.5 ft.Distance: Water Level, Sag in pipeCondition: 2Grade: N/ARemarks: 709.1 ft.Distance: Access Point End of PipeCondition: 0Grade: CAPPEDRemarks: Pic Report 4/Page Bio-Nomic Services516 Rountree Road Charlotte NC 28217(704) 529-0000 Pipe Joint...Width DUKE POWER RD OtherCharlotte Other CC3A 709.1 2 18 Circular MaterialGM #Location C...City DS Manhole Length surveyed HeightYear Renewed Year Laid Shape Street OtherSewer Use CC3Upstream MH 709.1Total Length Location Details 18 Page #:7MORGAN CORP CC4 Access Point Cleanout Mainline0.0 ft.ACCESS VIA LECHAE SYSTEM Water Level0.0 ft.2 Water Level, Sag in pipe158.3 ft.2 Water Level, Sag in pipe160.1 ft.3 CAMERA UNDER WATER Water Level, Sag in pipe198.1 ft.4 Deposits Settled Fine198.1 ft.2 Water Level, Sag in pipe240.0 ft.2 Water Level, Sag in pipe247.0 ft.2 Water Level, Sag in pipe255.7 ft.3 Access Point End of Pipe586.6 ft.CAPPED CC4A Plot Bio-Nomic Services516 Rountree Road Charlotte NC 28217(704) 529-0000 Pipe Joint...Width DUKE POWER RD OtherCharlotte Other CC4A 586.6 3 18 Circular MaterialGM #Location C...City DS Manhole Length surveyed HeightYear Renewed Year Laid Shape Street OtherSewer Use CC4Upstream MH 586.6Total Length Location Details 18 Pre-Acceptance 15:46 15:02 Very DryNo Pre-Cleaning 20160309OPRDirection PO NumberSPR QSR MPR QMR SPRI MPRI Time WeatherOPRI Purpose Pre-Cleaning Date Work Order Surveyed By Date Cleaned End Time Customer DownstreamBIO--NOMIC_HEMPHILL Additional Info Page #:8MORGAN CORP 0.0 ft.Distance: Access Point Cleanout MainlineCondition: 0Grade: ACCESS VIA LECHAE SYSTEMRemarks: 0.0 ft.Distance: Water LevelCondition: 2Grade: N/ARemarks: 158.3 ft.Distance: Water Level, Sag in pipeCondition: 2Grade: N/ARemarks: 160.1 ft.Distance: Water Level, Sag in pipeCondition: 3Grade: CAMERA UNDER WATERRemarks: Pic Report 4/Page Bio-Nomic Services516 Rountree Road Charlotte NC 28217(704) 529-0000 Pipe Joint...Width DUKE POWER RD OtherCharlotte Other CC4A 586.6 3 18 Circular MaterialGM #Location C...City DS Manhole Length surveyed HeightYear Renewed Year Laid Shape Street OtherSewer Use CC4Upstream MH 586.6Total Length Location Details 18 Page #:9MORGAN CORP 198.1 ft.Distance: Water Level, Sag in pipeCondition: 4Grade: N/ARemarks: 198.1 ft.Distance: Deposits Settled FineCondition: 2Grade: N/ARemarks: 240.0 ft.Distance: Water Level, Sag in pipeCondition: 2Grade: N/ARemarks: 247.0 ft.Distance: Water Level, Sag in pipeCondition: 2Grade: N/ARemarks: Pic Report 4/Page Bio-Nomic Services516 Rountree Road Charlotte NC 28217(704) 529-0000 Pipe Joint...Width DUKE POWER RD OtherCharlotte Other CC4A 586.6 3 18 Circular MaterialGM #Location C...City DS Manhole Length surveyed HeightYear Renewed Year Laid Shape Street OtherSewer Use CC4Upstream MH 586.6Total Length Location Details 18 Page #:10MORGAN CORP 255.7 ft.Distance: Water Level, Sag in pipeCondition: 3Grade: N/ARemarks: 586.6 ft.Distance: Access Point End of PipeCondition: 0Grade: CAPPEDRemarks: Pic Report 4/Page Bio-Nomic Services516 Rountree Road Charlotte NC 28217(704) 529-0000 Pipe Joint...Width DUKE POWER RD OtherCharlotte Other CC4A 586.6 3 18 Circular MaterialGM #Location C...City DS Manhole Length surveyed HeightYear Renewed Year Laid Shape Street OtherSewer Use CC4Upstream MH 586.6Total Length Location Details 18 Page #:11MORGAN CORP CC2 Access Point Cleanout Mainline0.0 ft.ACCESS VIA LECHAE LINE Water Level0.0 ft.2 Water Level, Sag in pipe118.8 ft.2 Access Point Tee Connection123.6 ft. Access Point Tee Connection123.6 ft. Shape or Size Change135.6 ft. Access Point End of Pipe828.8 ft.CAPPED CC2A Plot Bio-Nomic Services516 Rountree Road Charlotte NC 28217(704) 529-0000 Pipe Joint...Width DUKE POWER RD OtherCharlotte Other CC2A 828.8 1 18 Circular MaterialGM #Location C...City DS Manhole Length surveyed HeightYear Renewed Year Laid Shape Street OtherSewer Use CC2Upstream MH 828.8Total Length Location Details 18 Pre-Acceptance 16:47 16:07 Very DryNo Pre-Cleaning 20160309OPRDirection PO NumberSPR QSR MPR QMR SPRI MPRI Time WeatherOPRI Purpose Pre-Cleaning Date Work Order Surveyed By Date Cleaned End Time Customer DownstreamBIO--NOMIC_HEMPHILL Additional Info Page #:12MORGAN CORP 0.0 ft.Distance: Access Point Cleanout MainlineCondition: 0Grade: ACCESS VIA LECHAE LINERemarks: 0.0 ft.Distance: Water LevelCondition: 2Grade: N/ARemarks: 118.8 ft.Distance: Water Level, Sag in pipeCondition: 2Grade: N/ARemarks: 123.6 ft.Distance: Access Point Tee ConnectionCondition: 0Grade: N/ARemarks: Pic Report 4/Page Bio-Nomic Services516 Rountree Road Charlotte NC 28217(704) 529-0000 Pipe Joint...Width DUKE POWER RD OtherCharlotte Other CC2A 828.8 1 18 Circular MaterialGM #Location C...City DS Manhole Length surveyed HeightYear Renewed Year Laid Shape Street OtherSewer Use CC2Upstream MH 828.8Total Length Location Details 18 Page #:13MORGAN CORP 123.6 ft.Distance: Access Point Tee ConnectionCondition: 0Grade: N/ARemarks: 135.6 ft.Distance: Shape or Size ChangeCondition: 0Grade: N/ARemarks: 828.8 ft.Distance: Access Point End of PipeCondition: 0Grade: CAPPEDRemarks: Pic Report 4/Page Bio-Nomic Services516 Rountree Road Charlotte NC 28217(704) 529-0000 Pipe Joint...Width DUKE POWER RD OtherCharlotte Other CC2A 828.8 1 18 Circular MaterialGM #Location C...City DS Manhole Length surveyed HeightYear Renewed Year Laid Shape Street OtherSewer Use CC2Upstream MH 828.8Total Length Location Details 18 Page #:14MORGAN CORP