HomeMy WebLinkAbout2902_INSP_20171205FACILITY COMPLIANCE INSPECTION REPORT
Division of Waste Management
Solid Waste Section
Page 1 of 2
UNIT TYPE:
Lined
MSWLF LCID YW Transfer Compost SLAS COUNTY: Davidson
Closed
MSWLF X HHW White
goods Incin T&P FIRM PERMIT NO.: 2902
CDLF Tire T&P / Collection Tire Monofill Industrial Landfill DEMO SDTF FILE TYPE: COMPLIANCE
Date of Site Inspection: 12/05/2017 and 12/19/2017 Date of Last Inspection: 11/17/2016
FACILITY NAME AND ADDRESS:
Davidson County Integrated Solid Waste Management Facility
Holly Grove Landfill
220 Davidson County Landfill Road
Lexington, NC 27292
GPS COORDINATES: N: 35.850925° W: -80.178865°
FACILITY CONTACT NAME AND PHONE NUMBER:
Name: Rex Buck, Public Services Director
Telephone: 336-242-2008
Email address: rex.buck@davidsoncountync.gov
FACILITY CONTACT ADDRESS:
P. O. Box 1067
Lexington, NC 27293-1067
PARTICIPANTS:
Steven Sink, Landfill Supervisor – Davidson County
Susan Heim, Environmental Senior Specialist, Solid Waste Section
STATUS OF PERMIT:
Closed MSW landfill
PURPOSE OF SITE VISIT:
Comprehensive Inspection
STATUS OF PAST NOTED VIOLATIONS:
None
OBSERVED VIOLATIONS:
1. 15A NCAC 02C .0108(k) states: “All non-water supply wells, including temporary wells, shall be secured with a
locking well cap to ensure against unauthorized access and use.”
Davidson County is in violation of 15A NCAC 02C .0108(k) for failure to secure ground water and landfill
gas monitoring wells against unauthorized access and use.
As part of the facility comprehensive inspection, groundwater monitoring wells were inspected. Several of the
wells were found to be unsecured or to have broken locks.
To achieve compliance, Davidson County must secure all groundwater monitoring wells, piezometers and
probes with a locking cap. See table below for specific information about deficiencies.
FACILITY COMPLIANCE INSPECTION REPORT
Division of Waste Management
Solid Waste Section
Page 2 of 4
2. 15A NCAC 02C .0108(o) states: “Each non-water supply well shall have permanently affixed an identification
plate. The identification plate shall be constructed of a durable, waterproof, rustproof metal or other material
approved by the Department as equivalent and shall contain the following information:
(1) well contractor name and certification number;
(2) date well completed;
(3) total depth of well;
(4) a warning that the well is not for water supply and that the groundwater may contain hazardous materials;
(5) depth(s) to the top(s) and bottom(s) of the screen(s); and
(6) the well identification number or name assigned by the well owner.”
Davidson County is in violation of 15A NCAC 02C .0108(o) for failure to ensure that all non-water supply
wells have a permanently affixed identification plate constructed of a durable, waterproof, rustproof metal
or other approved material that includes all of the information required by this rule.
During this inspection, several of the monitoring wells were observed to be without the required permanent metal
identification plate.
To achieve compliance, Davidson County must affix a permanent metal identification plate, as specified in
15A NCAC 02C .0108(o), to the steel outer casing of all monitoring wells. See table below for specific
information about deficiencies.
SUMMARY OF OBSERVED VIOLATIONS:
The following table lists all monitoring wells and any deficiencies observed during the inspection that require attention:
Facility/Well
Type/Well ID
Lock
in
Place?
Lock
OK?
Steel
Casing
Present?
Steel
Casing
Intact?
Casing
Set in
Concrete?
Metal
ID
Plate?
Plate
OK?
Able
to
Access?
Holly Grove GM Wells:
GMW 1A Yes Yes Yes Yes No No No Yes
GMW 2 Yes Yes Yes Yes No No No Yes
GMW 3A Yes Yes Yes No Yes No No Yes
*GMW 4 GMW 4 is the same as GMW 15 of Phase I - 2906
GMW 5 Yes Yes Yes Yes partial No No Yes
GMW 6 Yes Yes Yes Yes Yes Yes Yes Yes
GMW 8 Yes Yes Yes Yes Yes Yes Yes Yes
GMW 9 Yes Yes Yes Yes Yes Yes Yes Yes
GMW 10 Yes Yes Yes Yes Yes Yes No ID# on plate Yes
GMW 11 Yes Yes Yes Yes Yes Yes No ID# on plate Yes
GMW 12 Yes Yes Yes Yes Yes Yes No ID# on plate Yes
GMW 13 Yes Yes Yes Yes Yes Yes No ID# on plate Yes
GMW 14 Yes Yes Yes Yes Yes Yes No info on plate Yes
GMW 15 Yes Yes Yes Yes Yes Yes Yes
not
easily
GMW 16 Yes Yes Yes Yes Yes Yes Yes Yes
GMW 17 Yes Yes Yes Yes Yes Yes No info on plate Yes
FACILITY COMPLIANCE INSPECTION REPORT
Division of Waste Management
Solid Waste Section
Page 3 of 4
CORRECTIVE MEASURES IN PROGRESS: Following this inspection, Mr. Sink notified me that he was working
with the county’s consultant, Smith-Gardner, to hire a contractor to inspect all landfill gas and groundwater monitoring
wells, piezometers and probes and perform any repairs necessary to ensure that they meet the standards set forth in 15A
NCAC 02C .0108, as required.
ADDITIONAL COMMENTS
1. The facility is a closed, unlined MSW landfill that ceased accepting waste in October 1993.
2. The primary focus of this inspection was the groundwater monitoring system.
3. All areas of the facility were easily accessible. Roadways are of all-weather construction and were observed to be
well-maintained.
4. The facility has well-established vegetative cover, and no signs of erosion were observed. Slope drains appeared to
be functioning. No ponding water was observed on the top or at the toe of the landfill.
5. Mowing had taken place at the facility the week prior to this inspection. Some woody vegetation was observed near
the toe of the landfill and around some of the slope drains. Mr. Sink indicated that he would have the mowing
contractor return and remove the woody vegetation from these areas. Please ensure that all woody vegetation is
removed from the cap of the landfill.
6. The public horse trail system that had been developed on the closed landfill property has fallen into disuse,
according to Mr. Sink. The automatic gate that had previously allowed access to the public had been replaced with
a padlock and heavy chain. Mr. Sink explained that some vandalism and illegal dumping had taken place at the
facility, and that increased security measures had been undertaken as a result.
7. Passive landfill gas vents located at the facility were observed. All were accessible and appeared to be functioning.
8. The groundwater monitoring system consists of 16 wells and 3 surface water points. All of the monitoring wells
were observed. (See Observed Violations section of this report for additional information.) Several of the
monitoring wells were difficult to access, due to heavy growth of underbrush and briars. Please ensure that the
area immediately surrounding each monitoring well is clear of vegetation and that all wells are accessible for
inspection and maintenance.
9. The semi-annual groundwater monitoring records for the sampling event that took place March 20-24, 2017 were
reviewed. SW-3 was not sampled as a part of this event because it was dry. The report covering the March 2017
sampling event indicated no exceedances of the 2L standards. The report for the fall 2017 sampling event had not
yet been received at the time of this inspection.
10. DS29-002, the temporary disaster debris storage site, is located adjacent to the closed landfill facility. The site is
secured with a gate and is easily accessible. The site was last activated in 2014, and Mr. Sink stated that it had been
adequate to handle temporary storage of the debris that had accumulated during that storm event.
The item(s) listed above were observed by Section staff and require action on behalf of the facility in order to come into or maintain compliance
with the Statutes, Rules, and/or other regulatory requirements applicable to this facility. Be advised that pursuant to N.C.G.S. 130A-22, an
administrative penalty of up to $15,000 per day may be assessed for each violation of the Solid Waste Laws, Regulations, Conditions of a Permit,
or Order under Article 9 of Chapter 130A of the N.C. General Statutes. Further, the facility and/or all responsible parties may also be subject to
enforcement actions including penalties, injunction from operation of a solid waste management facility or a solid waste collection service and any
such further relief as may be necessary to achieve compliance with the North Carolina Solid Waste Management Act and Rules.
FACILITY COMPLIANCE INSPECTION REPORT
Division of Waste Management
Solid Waste Section
Page 4 of 4
Please contact me if you have any questions or concerns regarding this inspection report.
________________________________________ Phone: 336-776-9672
Susan Heim
Environmental Senior Specialist
Regional Representative
Sent on: January 3, 2018 to
Rex Buck.
X Email Hand delivery US Mail
Copies: Deb Aja, Western District Supervisor – Solid Waste Section
Jaclynne Drummond, Solid Waste Section
Steven Sink, Landfill Supervisor – Davidson County