Loading...
HomeMy WebLinkAboutSLAS1205_INSP_20171207FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section Page 1 of 2 UNIT TYPE: Lined MSWLF LCID YW Transfer Compost SLAS X COUNTY: Burke Closed MSWLF HHW White goods Incin T&P FIRM PERMIT NO.: SLAS-12-05 CDLF Tire T&P / Collection Tire Monofill Industrial Landfill DEMO SDTF FILE TYPE: COMPLIANCE Date of Site Inspection: December 7, 2017 Date of Last Inspection: March 20, 2017 FACILITY NAME AND ADDRESS: Williams Septic Tank Service 1922 Baton School Road Lenoir, NC 28645 GPS COORDINATES: N: 35.80474° W: 81.59062° FACILITY CONTACT NAME AND PHONE NUMBER: Name: Marshall and Darlene Williams Telephone: (828) 728-7116 Home (828) 381-5319 Cell FACILITY CONTACT ADDRESS: P.O. Box 546 Hudson, NC 28638 PARTICIPANTS: Troy Harrison, NC Solid Waste Section STATUS OF PERMIT: Active Issued: 2/27/2014 Expires: 2/27/2019 PURPOSE OF SITE VISIT: Routine Inspection STATUS OF PAST NOTED VIOLATIONS: N/A OBSERVED VIOLATIONS: N/A The item(s) listed above were observed by Section staff and require action on behalf of the facility in order to come into or maintain compliance with the Statutes, Rules, and/or other regulatory requirements applicable to this facility. Be advised that pursuant to N.C.G.S. 130A-22, an administrative penalty of up to $15,000 per day may be assessed for each violation of the Solid Waste Laws, Regulations, Conditions of a Permit, or Order under Article 9 of Chapter 130A of the N.C. General Statutes. Further, the facility and/or all responsible parties may also be subject to enforcement actions including penalties, injunction from operation of a solid waste management facility or a solid waste collection service and any such further relief as may be necessary to achieve compliance with the North Carolina Solid Waste Management Act and Rules. FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section Page 2 of 2 ADDITIONAL COMMENTS 1. The Septage Land Application Site consists of two fields totaling 6.5 acres with Field 1 (3.1 acres) and Field 2 (3.4 acres). Field 2 Field 1 2. The site is permitted for land application of domestic septage and grease septage. 3. The site is located on Dogwood Vista Road and had accessible all-weather roads to the septage land application fields covered under the permit. 4. Appropriate signage was displayed at the site 5. Disposal area boundaries were delineated with permanent markers. 6. All septage discharges appear to have been made within the disposal area boundary. 7. The waste appeared to be evenly distributed throughout the fields. 8. No objectionable odors were observed. 9. As a reminder, the Nutrient Management Plan (NMP) requires that areas that develop less than 80% ground cover must be reseeded with fescue at a rate of 15 lbs/acre. Please contact me if you have any questions or concerns regarding this inspection report. _________________________________________ Phone: (828) 296-4701 Troy Harrison Environmental Senior Specialist Regional Representative Sent on 12/14/2017 Email Hand delivery X US Mail Certified No. [ _] Copies: Connie Wylie, Solid Waste Section