Loading...
HomeMy WebLinkAboutSDTF1902_INSP_20171121FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section Page 1 of 2 UNIT TYPE: Lined MSWLF LCID YW Transfer Compost SLAS COUNTY: Chatham Closed MSWLF HHW White goods Incin T&P FIRM PERMIT NO.: SDTF 19-02 CDLF Tire T&P / Collection Tire Monofill Industrial Landfill DEMO SDTF X FILE TYPE: COMPLIANCE Date of Site Inspection: 11/21/2017 Date of Last Inspection: 2/02/2017 FACILITY NAME AND ADDRESS: East Coast Resources 51 Buttonwood Court Fuquay Varina, NC 27526 GPS COORDINATES: N: 35.63138 E: -79.01333 FACILITY CONTACT NAME AND PHONE NUMBER: Name: Damon Woodall Telephone: (919) 577-1995 Email address: ecrww@yahoo.com Fax: (919) 577-1998 FACILITY CONTACT ADDRESS: Same as above PARTICIPANTS: Connie Wylie, Damon Woodall STATUS OF PERMIT: Active – permit expires January 15, 2020 PURPOSE OF SITE VISIT: Routine STATUS OF PAST NOTED VIOLATIONS: N/A OBSERVED VIOLATIONS: N/A SEE BACK The item(s) listed above were observed by Section staff and require action on behalf of the facility in order to come into or maintain compliance with the Statutes, Rules, and/or other regulatory requirements applicable to this facility. Be advised that pursuant to N.C.G.S. 130A-22, an administrative penalty of up to $15,000 per day may be assessed for each violation of the Solid Waste Laws, Regulations, Conditions of a Permit, or Order under Article 9 of Chapter 130A of the N.C. General Statutes. Further, the facility and/or all responsible parties may also be subject to enforcement actions including penalties, injunction from operation of a solid waste management facility or a solid waste collection service and any such further relief as may be necessary to achieve compliance with the North Carolina Solid Waste Management Act and Rules. FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section Page 2 of 2 ADDITIONAL COMMENTS 1. Noted a possible spill at the truck unloading area up top. Appears to be from a hose and Mr. Woodall stated that he would have it cleaned up. Please ensure that septage is transferred to/from the facility in a safe and sanitary manner. No odors or vectors noted at this time. 2. The three tanks appears structurally sound but are still tilted. No active repair work on the side wall at this time. 3. The approved setbacks are being met. No physical change in facility. 4. The required 5’ cleared radius around the tanks is present at this time. 5. The required signs are posted at the gate entrance and the access road is adequate. 6. Thank you for your time. Please contact me if you have any questions or concerns regarding this inspection report. ____ _ Phone: (910) 433-3352 Connie S. Wylie Regional Representative Sent on: Email Hand delivery X US Mail Certified No. [ _]