Loading...
HomeMy WebLinkAbout0601_AveryCoMSW_LFGM_DIN28586_20171016 October 16, 2017 Ms. Jaclynne Drummond NCDENR DWM Solid Waste Section 2090 U.S. 70 Highway Swannanoa, North Carolina 28778-8211 RE: Operations, Monitoring, and Maintenance Report –September 2017 Avery County Closed MSW Landfill Spruce Pine, North Carolina Dear Ms. Drummond: Smith Gardner, Inc. (S+G) is pleased to present this report concerning the operation and maintenance (O&M) of the Avery County Closed MSW Landfill (Permit No. 06-01) Landfill Gas Collection and Control System (LFGCCS). Monitoring of the on- and off-site landfill gas probes was also performed. Mr. Frank Terry with S+G performed the site visit on September 28, 2017. Site visit details are provided below. LFG EXTRACTION WELL MONITORING PROGRAM Monthly monitoring of the LFGCCS will continue and shall include the following items: • CH4, O2, CO2, and pressure monitoring at each extraction well head; • CH4, O2, CO2, and pressure monitoring at the flare station; and • Adjustment of the LFGCCS to balance recovery and ensure safe system operation. The County will maintain this LFGCCS and will continue to evaluate the effectiveness of increased LFG recovery from the waste mass in alleviating off-site LFG migration. Results from monthly monitoring events will be reported in accordance with the approved LFG Monitoring Plan. LFG EXTRACTION WELL MONITORING ACTIVITIES Mr. Terry performed the flare station and well field monitoring on September 28, 2017. Initial measurements indicated there was approximately 31 inches of available vacuum at the vacuum blower inlet, resulting in approximately 29 inches of available vacuum at each of the LFG wells across the well field. The results from this event are summarized below. Recommended actions are underlined. Well field data and flare station data are provided in the attached Table 1. Ms. Drummond October 16, 2017, 2017 Page 2 of 3 LFG Extraction Well Field • W-1 through W-10: S+G performed methane (CH4), oxygen (O2), carbon dioxide (CO2), and pressure monitoring. No wellhead valves adjustments were required during this sampling event. • Orifice Plates: S+G continues to evaluate orifice plate sizes at wells W-5, W-7, W- 9, and W-10 during each site visit. LFG flow potential at these locations continues to remain stable, the correct orifice plate sizes are currently installed and no further changes were made. Flare Station • Condensate Tank: The condensate tank was at an acceptable level during this site visit. S+G will continue to monitor the liquid level of the condensate tank. • Filter Tank: The filter tank was at an acceptable level during this site visit. S+G will continue to monitor the liquid level of the filter tank. • Flare operation: Due to low methane concentration of approximately 10% measured at the flare no active combustion was observed. The spark ignition system was operational; however, flame ignition continues to be unsuccessful. S+G will continue to adjust the system to optimize gas flow and quality. LFG MONITORING WELL (PERIMETER) MONITORING PROGRAM Mr. Terry performed monitoring of the perimeter LFG monitoring network during this event. Monitoring Wells P-1, P-3, P-7, and P-13 exhibited CH4 concentration readings of 2.2%, 2.2%, 2.4%, and 0.5% respectively which do not exceed the LEL of 5%. The other wells, monitored during this event, had no detectable concentrations of CH4. Results of this monitoring event are included in Attachment 1. Attachment 2 provides a CH4 concentration graph over time for monitoring wells that have historically had methane present. The current well network will continue to be monitored and data will be reported to NCDEQ and the County. CONCLUSIONS The site has been generally characterized by a trend of consistently decreasing LFG concentrations and flow rate. Methane concentrations have decreased slightly from the July 2017 monitoring event in several probes during this monitoring event. We will continue to monitor the CH4 concentrations at the site monthly. Ms. Drummond October 16, 2017, 2017 Page 3 of 3 The next routine monitoring event is scheduled for October 2017. If you have any questions, or require additional information, please contact us at your earliest convenience at 919-828-0577 or by e-mail (address below). Sincerely, SMITH GARDNER, INC. Frank Terry Madeline German, P.G. Project Manager, ext. 142 Project Geologist ext. 222 frank@smithgardnerinc.com madeline@smithgardnerinc.com Attachments cc: Eric Foster – Avery County Kris Riddle – NCDEQ file H:\Projects\Avery County (NC)\Avery-15-1 (LFG Sys Ops)\2017 LFG Monitoring\9 Sept 2017\Avery Co MSW LFG Monitoring Rpt September 2017.docx This page intentionally left blank. Attachment 1 This page intentionally left blank. TABLE This page intentionally left blank. DATE: BY:FAT Date/Time CH4 CO2 O2 Balance Init. Temperature Init. Static Pressure Adj. Static Pressure Adj. Diff. Pressure*Init. Flow Adj. Flow System Pressure mm/dd/yyyy %%%%deg F in H2O in H2O in H2O Scfm Scfm in H2O AVERY-W1 9/28/2017 12:53 68.5 28.1 0.1 3.3 93 -28.8 -28.7 0.0 0.0 2.8 -29.3 AVERY-W2 9/28/2017 12:45 48.3 27.4 0.6 23.7 77 -29.0 -29.0 0.0 4.0 8.0 -29.0 AVERY-W3 9/28/2017 12:30 63.7 30.3 0.1 5.9 81 -29.0 -29.3 0.0 0.0 0.0 -29.3 AVERY-W4 9/28/2017 12:48 32.5 24.4 0.0 43.1 91 -29.0 -29.0 0.0 0.0 0.0 -29.0 AVERY-W5 9/28/2017 13:08 29.9 25.0 0.4 44.7 88 -28.6 -28.5 0.5 2.1 2.2 -29.3 AVERY-W6 9/28/2017 13:11 12.3 21.2 1.8 64.7 85 -6.3 -6.5 0.0 3.9 2.7 -29.0 AVERY-W7 9/28/2017 13:05 7.8 18.0 3.2 71.0 74 -3.3 -3.3 3.7 1.5 1.5 -29.2 AVERY-W8 9/28/2017 13:14 49.0 36.0 0.9 14.1 90 -29.4 -29.4 0.0 8.3 8.3 -29.0 AVERY-W9 9/28/2017 12:57 38.1 25.6 0.1 36.2 99 -29.0 -29.0 0.1 0.2 0.2 -29.0 AVERY-W10 9/28/2017 12:37 56.9 31.1 1.9 10.1 88 -29.0 -29.0 0.1 0.2 0.3 -29.0 Av-Flare 9/28/2017 13:38 13.4 9.5 12.8 64.3 NR -31.1 -31.3 31.7 NR NR 0.0 NR= not recorded Landfill Gas Collection and Control System Monitoring September 2017 *The differential pressure measurement should be positive. A negative differential pressure may indicate no gas flow.   Negative differential pressure can be the result of dirt or water obstructing the pitot tube perforations.  Overpulling by adjacent extraction wells may also result in negative pressure being displayed. October 16, 2017 Avery County Closed MSW Landfill TABLE 1 Device ID This page intentionally left blank. NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Facility Name: ______________________________________________ Permit Number: ____________________________ Date of Sampling: ___________________ NC Landfill Rule (.0500 or .1600): _____________________________________ Name and Position of Sample Collector: _________________________________________ Type and Serial Number of Gas Meter: _______________________________ Calibration Date of Gas Meter: ___________ Date and Time of Field Calibration: _____________________ Type of Field Calibration Gas (15/15 or 35/50): ____________ Expiration Date of Field Calibration Gas Canister: ________ Pump Rate of Gas Meter: _____________ Ambient Air Temperature: __________ Barometric Pressure: ______________ General Weather Conditions: _____________ Instructions: Under “Location or LFG Well” identify the monitoring wells or describe the location for other tests (e.g., inside buildings). A drawing showing the location of test must be attached. Report methane readings in both % LEL and % methane by volume. A reading in percent methane by volume can be converted to % LEL as follows: % methane by volume = % LEL/20 If your facility has more gas monitoring locations than there is room on this form, please attach additional sheets listing the same information as contained on this form. Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. __________________________________ ________________________ SIGNATURE TITLE ________________________________________________________________________________________________________________________________________________________________________________ RRRRRRRREEEEEEEEEEEEEEEEEEEEEEEEE Person County Closed MSW Landfill 73-01 .0500 Avery County Closed MSW Landfill 06-01 9/28/17 .0500 Frank Terry S+G Envision ENV100 1510204 12/2016 9/28/17 12:00AM 10/2018 /30 75 30.00 Hg Sunny P-1 !V 13:50 PM !V 44.0 44.0 2.2 19.8 1.3 P-2 !V 13:54 PM !V 0.0 0.0 0.0 21.3 0 P-3 !V 13:57 PM !V 44.0 44 2.2 18.1 2.4 P-4 !V 14:02 PM !V 0.0 0.0 0.0 16.8 7.1 P-5 !V 14:08 PM !V 0.0 0.0 0.0 18.5 3.6 P-6 !V 14:33 PM !V 0.0 0.0 0.0 16.8 4.8 P-7 !V 13:21PM !V 48.0 48.0 2.4 0.1 19.4 P-8 !V 13:35 PM !V 0.0 0.0 0.1 15.8 5.8 P-9 !V 14:50 PM !V 0.0 0.0 0.0 20.2 1.0 P-10 !V 15:01 PM !V 0.0 0.0 0.0 15.3 5.4 P-11 >60s 14:55 PM >60s 0.0 0.0 0.0 17.6 2.1 P-12 >60s 13:27 PM >60s 0.0 0.0 0.0 21.3 0.0 P-13 >60s 15:10 PM >60s 4.0 4.0 0.8 5.5 13.0 Project Manager NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Facility Name: ______________________________________________ Permit Number: ____________________________ Date of Sampling: ___________________ NC Landfill Rule (.0500 or .1600): _____________________________________ Name and Position of Sample Collector: _________________________________________ Type and Serial Number of Gas Meter: _______________________________ Calibration Date of Gas Meter: ___________ Date and Time of Field Calibration: _____________________ Type of Field Calibration Gas (15/15 or 35/50): ____________ Expiration Date of Field Calibration Gas Canister: ________ Pump Rate of Gas Meter: _____________ Ambient Air Temperature: __________ Barometric Pressure: ______________ General Weather Conditions: _____________ Instructions: Under “Location or LFG Well” identify the monitoring wells or describe the location for other tests (e.g., inside buildings). A drawing showing the location of test must be attached. Report methane readings in both % LEL and % methane by volume. A reading in percent methane by volume can be converted to % LEL as follows: % methane by volume = % LEL/20 If your facility has more gas monitoring locations than there is room on this form, please attach additional sheets listing the same information as contained on this form. Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. __________________________________ ________________________ SIGNATURE TITLE .0500 Avery County Closed Landfill 06-01 9/28/17 .0500 Frank Terry S+G Envision ENV100 1510204 12/2016 9/28/17 12:00PM 15/15 10/2018 0.5 L/min 75 30.00 Sunny Avery County Airport Structure #1 NE Corner >60s 1520 >60s 0 0 0 20.9 0 NW Corner >60s 1523 >60s 0 0 0 20.9 0 SE Corner >60s 1526 >60s 0 0 0 20.9 0 SW Corner >60s 1529 >60s 0 0 0 20.9 0 Avery County Airport Structure #2 NE Corner >60s 1532 >60s 0 0 0 20.9 0 NW Corner >60s 1535 >60s 0 0 0 20.9 0 SE Corner >60s 1538 >60s 0 0 0 20.9 0 SW Corner >60s 1541 >60s 0 0 0 20.9 0 Avery County Airport Structure #3 NE Corner >60s 1544 >60s 0 0 0 20.9 0 NW Corner >60s 1547 >60s 0 0 0 20.9 0 SE Corner >60s 1500 >60s 0 0 0 20.9 0 SW Corner >60s 1503 >60s 0 0 0 20.9 0 Avery County Airport Structure #4 NE Corner >60s 1506 >60s 0 0 0 20.9 0 NW Corner >60s 1509 >60s 0 0 0 20.9 0 SE Corner >60s 1512 >60s 0 0 0 20.9 0 SW Corner >60s 1515 >60s 0 0 0 20.9 0 Avery County Airport Structure #5 NE Corner >60s 1518 >60s 0 0 0 20.9 0 NW Corner >60s 1521 >60s 0 0 0 20.9 0 SE Corner >60s 1524 >60s 0 0 0 20.9 0 SW Corner >60s 1527 >60s 0 0 0 20.9 0 Project Manager, S+G NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Facility Name: ______________________________________________ Permit Number: ____________________________ Date of Sampling: ___________________ NC Landfill Rule (.0500 or .1600): _____________________________________ Name and Position of Sample Collector: _________________________________________ Type and Serial Number of Gas Meter: _______________________________ Calibration Date of Gas Meter: ___________ Date and Time of Field Calibration: _____________________ Type of Field Calibration Gas (15/15 or 35/50): ____________ Expiration Date of Field Calibration Gas Canister: ________ Pump Rate of Gas Meter: _____________ Ambient Air Temperature: __________ Barometric Pressure: ______________ General Weather Conditions: _____________ Instructions: Under “Location or LFG Well” identify the monitoring wells or describe the location for other tests (e.g., inside buildings). A drawing showing the location of test must be attached. Report methane readings in both % LEL and % methane by volume. A reading in percent methane by volume can be converted to % LEL as follows: % methane by volume = % LEL/20 If your facility has more gas monitoring locations than there is room on this form, please attach additional sheets listing the same information as contained on this form. Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. __________________________________ ________________________ SIGNATURE TITLE .0500 Avery County Closed Landfill 06-01 9/28/17 .0500 Frank Terry S+G Envision ENV100 1510204 12/2016 9/28/17 12:00PM 15/15 10/2018 0.5 L/min 75 30.00 Sunny Project Manager, S+G Avery County Airport Structure #6 NE Corner >60s 1530 >60s 0 0 0 20.9 0 NW Corner >60s 1533 >60s 0 0 0 20.9 0 SE Corner >60s 1539 >60s 0 0020.9 0 SW Corner >60s 1542 >60s 0 0 0 20.9 0 Attachment 2 This page intentionally left blank. By:FAT Date:10/16/2017 Avery County MSW Landfill Landfill Gas Monitoring Well Network Methane Concentrations Between May 2011 and September 2017 0.0 10.0 20.0 30.0 40.0 50.0 60.0 70.0 Nov-11Dec-11Jan-12Feb-12Mar-12Apr-12May-12Jun-12Jul-12Aug-12Sep-12Oct-12Nov-12Dec-12Jan-13Feb-13Mar-13Apr-13May-13Jun-13Jul-13Aug-13Sep-13Oct-13Nov-13Dec-13Jan-14Feb-14Mar-14Apr-14May-14Jun-14Jul-14Aug-14Sep-14Oct-14Nov-14Dec-14Jan-15Feb-15Mar-15Apr-15May-15Jun-15Jul-15Aug-15Sep-15Oct-15Nov-15Dec-15Jan-16Feb-16Mar-16Apr-16May-16Jun-16Jul-16Aug-16Sep-16Oct-16Nov-16Dec-16Jan-17Feb-17Mar-17Apr-17May-17Jun-17Jul-17Aug-17Sep-17P1 P3 P7 P11 P12 P13 Well % CH4 by Volume Installation of W9 and W10 (April 30, 2013) Installation of W9/P3 Connection (September 11, 2014 Installation of P7/W8 and P1/W10 Connection (September 3, 2015) This page intentionally left blank. FIGURE This page intentionally left blank. 0200'400'1234564G:\CAD\Avery County\Avery 13-6\sheets\AVERY-B0216.dwg - 12/3/2013 11:03 AM           This Page Intentionally Left Blank