Loading...
HomeMy WebLinkAboutSLAS7406_INSP_20160510FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section Page 1 of 2 UNIT TYPE: Lined MSWLF LCID YW Transfer Compost SLAS X COUNTY: Pitt Closed MSWLF HHW White goods Incin T&P FIRM PERMIT NO.: SLAS-74-06 CDLF Tire T&P / Collection Tire Monofill Industrial Landfill DEMO SDTF FILE TYPE: COMPLIANCE Date of Site Inspection: 05/10/16 Date of Last Inspection: 11/18/15 FACILITY NAME AND ADDRESS: Curtis L. Matthews Matthews Septic Tank Service PO Box 85 Farmville, NC 27828 GPS COORDINATES: N: 35.55954 E: -77.54032 FACILITY CONTACT INFORMATION: Name: Curtis L. Matthews Jr. Address: PO Box 233 – Farmville, NC 27828 Telephone: 252-714-7890 (Virginia) Email address: matthewsseptictank@yahoo.com PARTICIPANTS: Chester Cobb STATUS OF PERMIT: Active EXPIRES: 10/12/16 PURPOSE OF SITE VISIT: Routine STATUS OF PAST NOTED VIOLATIONS: No violations noted on the previous inspection conducted on 11/18/15. OBSERVED VIOLATIONS: NONE The item(s) listed above were observed by Section staff and require action on behalf of the facility in order to come into or maintain compliance with the Statutes, Rules, and/or other regulatory requirements applicable to this facility. Be advised that pursuant to N.C.G.S. 130A-22, an administrative penalty of up to $15,000 per day may be assessed for each violation of the Solid Waste Laws, Regulations, Conditions of a Permit, or Order under Article 9 of Chapter 130A of the N.C. General Statutes. Further, the facility and/or all responsible parties may also be subject to enforcement actions including penalties, injunction from operation of a solid waste management facility or a solid waste collection service and any such further relief as may be necessary to achieve compliance with the North Carolina Solid Waste Management Act and Rules. FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section Page 2 of 2 AREAS OF CONCERN AND COMMENTS: 1) The “Septage Land Application” site and “No Trespassing” sign present at the entrance to the fields. 2) The access road is in good shape. 3) All field markers were up for both fields. 4) All septage discharges appeared to be within the permitted boundaries of the two fields. 5) No application issues noted today. Septage application have been currently going to Field 2. 6) Ryegrass present on both fields. The ryegrass needs to be harvested. 7) No application at time of inspection. pH not checked. 8) No objectionable odors noticed today. 9) No change noticed that would affect setback distances. Ryegrass present on both fields. Please contact me if you have any questions or concerns regarding this inspection report. ____________________________ Phone: (919) 707-8283 . Chester R. Cobb, Soil Scientist Division of Waste Management, NCDEQ Regional Representative Sent on: 07/06/16 Email Hand delivery X US Mail Certified No. [ _]