HomeMy WebLinkAbout1107_BuncombeCountyMSW_GWMR_DIN28339_20170421 SCS Engineers, P.C. Environmental Consultants 4767 New Broad Street 407 514-2766 and Contractors Suite 222 FAX 407 514-2604 Orlando, FL 32814 www.scsengineers.com
Offices Nationwide
July 11, 2017
File No. 09204072.15
Mrs. Jackie Drummond Compliance Hydrogeologist Division of Waste Management - Solid Waste Section
North Carolina Department of Environmental Quality
Asheville Regional Office 2090 US Highway 70, Swannanoa, NC 28778 Subject: Spring 2017 Semi- Annual Sampling Report for Buncombe County Solid Waste Management Facility New Landfill
Permit No. 1107
Dear Mrs. Drummond: The purpose of this letter is to notify the North Carolina Department of Environmental Quality
(NCDEQ) Solid Waste Section that semi-annual sampling has been completed at the Buncombe County Solid Waste Management Facility New Landfill located at 85 Panther Road in Alexander, North Carolina. Sampling and reporting was conducted in accordance with 15A NCAC 13B.1632. This letter summarizes the sampling activities and results of the spring 2017 semi-annual sampling event.
Water quality samples were collected from 25 monitoring wells and surface water and leachate sampling locations. Groundwater samples were collected from April 25 through 27, 2016. Six surface water and six leachate samples were collected on April 21 and 24, 2017. All samples were collected and analyzed by Pace Laboratories in Asheville, NC for analysis of the current
landfill constituents list: Appendix I Volatile Organic Compounds (VOCs) (EPA 8260); Appendix I Metals (EPA 6010) plus mercury (EPA 7470), sulfate (EPA 300.0), chloride (SM 4500-Cl-E), Alkalinity (SM 2320B), and Total Dissolved Solids (SM 2540C). Groundwater elevations were also measured and groundwater contour maps for both the shallow
and deep flow regimes as presented in Attachment A. Field parameters and well conditions were evaluated and recorded and are presented in Attachment B Well Condition Summary and Attachment C Field Report Forms & COCs. Field parameters recorded in the field report include: pH, specific conductivity, temperature, dissolved oxygen, and oxidation/reduction potential, temperature, and turbidity. Field parameters were also measured at the surface water
sampling locations. Metals detected in groundwater samples include barium, chromium, cobalt, copper, iron, manganese, nickel, vanadium and zinc. Other detected constituents include chloride, sulfate and total dissolved solids. No VOCs were detected in groundwater samples.
Buncombe County New Landfill Spring 2017 Semi-Annual Sampling
Iron, vanadium and manganese were the only constituents in monitoring well samples that
exceed North Carolina 2L (NC2L) Groundwater Standards (GWS). Eight of the 25 monitoring
wells had concentrations in excess of the NC2L GWS. These concentrations are consistent with previous sampling results and are generally recognized as naturally occurring, as evidenced in the Alternate Source Demonstration (ASD) submitted January 4, 2017. Groundwater concentrations exceeding the NC2L GWSs are summarized as follows: Iron exceeded the
maximum contaminate level (MCLs of 300 micrograms per liter (ug/L) in MW-1 (2,610 ug/L),
MW-12 (1,120 ug/L), MW-12D (894 ug/L), MW-14 (1,730 ug/L) and MW-15S (4,800 ug/L). Vanadium exceeded the MCL of 0.3 ug/L in MW-1 (6.8 ug/L), MW13D (6.8 ug/L), MW-14 (6.0 ug/L), MW-15S (18.5 ug/L) and MW-4 (8.1 ug/L).Manganese exceeded the MCL of 50 ug/L in MW-15D (358 ug/L) and MW-15S (10,600 ug/L). No Appendix I VOCs were detected or
exceeded MCLs in groundwater samples.
Metal constituents detected in surface water samples include barium, copper, nickel and zinc. No Appendix I VOCs were detected in surface water samples. Surface water sample results did not exceed NC2L Surface Water Standard (SWS).
Metal constituents detected in leachate samples include arsenic, antimony, barium, chromium, cobalt, copper, nickel, thallium, vanadium and zinc. VOC constituents detected in leachate samples include 1,1-dichloroethane, 1,4-dichlorobenzene, acetone, benzene, ethylbenzene, xylene, σ-xylene, toluene and vinyl chloride.
Leachate sampling demonstrated no constituents exceeding NC2L GSWS reporting limits. A table of detections is provided as Attachment D and a table of exceedances is provided as Attachment E.
The next Semi-Annual sampling event is scheduled for fall 2017. Please contact us if you have any questions or comments regarding this correspondence.
Sincerely,
.Kayla Ouellette C. Ed Hilton, Jr. P.E
Project Professional Vice President/Project Manager
SCS ENGINEERS SCS ENGINEERS KJO/CEH: kjo
Buncombe County New Landfill Spring 2017 Semi-Annual Sampling
ATTACHMENT A
FIGURES
Buncombe County New Landfill Spring 2017 Semi-Annual Sampling
ATTACHMENT B
WELL CONDITION SUMMARY
Buncombe County New Landfill Spring 2017 Semi-Annual Sampling
ATTACHMENT C
FIELD REPORT FORMS & COCs
Buncombe County New Landfill Spring 2017 Semi-Annual Sampling
ATTACHMENT D
DETECTION TABLES
Groundwater Detection Summary Report
Buncombe County New Facility
From:01/01/2017 To:06/06/2017
Well ID Parameter Sample Date Result Flags Units
MW‐1
Alkalinity, Total
4/26/2017 43800 ug/L
Barium, Dissolved
4/26/2017 133 ug/L
Barium, Total
4/26/2017 146 ug/L
Chloride
4/26/2017 4900 ug/L
Dissolved Oxygen
4/26/2017 6.32 mg/L
Iron, Total
4/26/2017 2610 ug/L
Manganese, Total
4/26/2017 27.9 ug/L
ORP ‐ Field
4/26/2017 147.1 mV
pH ‐ Field
4/26/2017 6.3 Std. Units
Specific Conductivity ‐ Field
4/26/2017 161 umhos/cm
Sulfate
4/26/2017 16400 ug/L
Temperature ‐ Field
4/26/2017 14.4 deg C
Total Dissolved Solids
4/26/2017 114000 ug/L
Turbidity ‐ Field
4/26/2017 19.39 NTU
Vanadium, Total
4/26/2017 6.8 ug/L
MW‐10
Barium, Dissolved
U = Indicates that the compound was analyzed for but not detected.
BDL = Indicates that the compound was analyzed for but not detected.
I = The reported value is between the laboratory method detection limit and the laboratory practical quatitation limit.V = Indicates the anlyte was detected in both the sample and the associated method blank.
Wednesday, June 21, 2017 Page 1 of 18
Well ID Parameter Sample Date Result Flags Units
MW‐10
Barium, Dissolved
4/25/2017 126 ug/L
Barium, Total
4/25/2017 141 ug/L
Dissolved Oxygen
4/25/2017 3.16 mg/L
ORP ‐ Field
4/25/2017 284 mV
pH ‐ Field
4/25/2017 6.1 Std. Units
Specific Conductivity ‐ Field
4/25/2017 314 umhos/cm
Temperature ‐ Field
4/25/2017 15.6 deg C
Turbidity ‐ Field
4/25/2017 1.61 NTU
Zinc, Total
4/25/2017 17.5 ug/L
MW‐10D
Barium, Dissolved
4/25/2017 14.9 ug/L
Barium, Total
4/25/2017 17.9 ug/L
Dissolved Oxygen
4/25/2017 3.93 mg/L
Nickel, Dissolved
4/25/2017 7.2 ug/L
Nickel, Total
4/25/2017 8.6 ug/L
ORP ‐ Field
4/25/2017 271.6 mV
pH ‐ Field
4/25/2017 6.5 Std. Units
Specific Conductivity ‐ Field
4/25/2017 291 umhos/cm
Temperature ‐ Field
U = Indicates that the compound was analyzed for but not detected.
BDL = Indicates that the compound was analyzed for but not detected.
I = The reported value is between the laboratory method detection limit and the laboratory practical quatitation limit.V = Indicates the anlyte was detected in both the sample and the associated method blank.
Wednesday, June 21, 2017 Page 2 of 18
Well ID Parameter Sample Date Result Flags Units
MW‐10D
Temperature ‐ Field
4/25/2017 15.2 deg C
Turbidity ‐ Field
4/25/2017 3.5 NTU
MW‐11
Barium, Dissolved
4/25/2017 89.5 ug/L
Barium, Total
4/25/2017 105 ug/L
Dissolved Oxygen
4/25/2017 5.27 mg/L
Nickel, Dissolved
4/25/2017 10.2 ug/L
Nickel, Total
4/25/2017 10.2 ug/L
ORP ‐ Field
4/25/2017 231.5 mV
pH ‐ Field
4/25/2017 6.6 Std. Units
Specific Conductivity ‐ Field
4/25/2017 428 umhos/cm
Temperature ‐ Field
4/25/2017 16.2 deg C
Turbidity ‐ Field
4/25/2017 6.46 NTU
Zinc, Dissolved
4/25/2017 13.1 ug/L
MW‐11D
Barium, Dissolved
4/25/2017 14.6 ug/L
Barium, Total
4/25/2017 14.3 ug/L
Dissolved Oxygen
4/25/2017 3.45 mg/L
Nickel, Total
4/25/2017 5 ug/L
U = Indicates that the compound was analyzed for but not detected.
BDL = Indicates that the compound was analyzed for but not detected.
I = The reported value is between the laboratory method detection limit and the laboratory practical quatitation limit.V = Indicates the anlyte was detected in both the sample and the associated method blank.
Wednesday, June 21, 2017 Page 3 of 18
Well ID Parameter Sample Date Result Flags Units
MW‐11D
ORP ‐ Field
4/25/2017 227.1 mV
pH ‐ Field
4/25/2017 6.5 Std. Units
Specific Conductivity ‐ Field
4/25/2017 397 umhos/cm
Temperature ‐ Field
4/25/2017 15.8 deg C
Turbidity ‐ Field
4/25/2017 11.27 NTU
Zinc, Dissolved
4/25/2017 10.2 ug/L
MW‐12
Alkalinity, Total
4/26/2017 106000 ug/L
Barium, Dissolved
4/26/2017 34.2 ug/L
Barium, Total
4/26/2017 36.9 ug/L
Chloride
4/26/2017 20700 ug/L
Dissolved Oxygen
4/26/2017 3.45 mg/L
Iron, Total
4/26/2017 1120 ug/L
Manganese, Total
4/26/2017 49.2 ug/L
ORP ‐ Field
4/26/2017 214.2 mV
pH ‐ Field
4/26/2017 6.3 Std. Units
Specific Conductivity ‐ Field
4/26/2017 682 umhos/cm
Sulfate
4/26/2017 127000 ug/L
Temperature ‐ Field
U = Indicates that the compound was analyzed for but not detected.
BDL = Indicates that the compound was analyzed for but not detected.
I = The reported value is between the laboratory method detection limit and the laboratory practical quatitation limit.V = Indicates the anlyte was detected in both the sample and the associated method blank.
Wednesday, June 21, 2017 Page 4 of 18
Well ID Parameter Sample Date Result Flags Units
MW‐12
Temperature ‐ Field
4/26/2017 15.9 deg C
Total Dissolved Solids
4/26/2017 462000 ug/L
Turbidity ‐ Field
4/26/2017 17.79 NTU
MW‐12D
Alkalinity, Total
4/26/2017 98000 ug/L
Barium, Dissolved
4/26/2017 42.9 ug/L
Barium, Total
4/26/2017 49.4 ug/L
Chloride
4/26/2017 10400 ug/L
Dissolved Oxygen
4/26/2017 3.91 mg/L
Iron, Total
4/26/2017 894 ug/L
Manganese, Total
4/26/2017 22.4 ug/L
ORP ‐ Field
4/26/2017 199.1 mV
pH ‐ Field
4/26/2017 6.4 Std. Units
Specific Conductivity ‐ Field
4/26/2017 399 umhos/cm
Sulfate
4/26/2017 69000 ug/L
Temperature ‐ Field
4/26/2017 14.9 deg C
Total Dissolved Solids
4/26/2017 258000 ug/L
Turbidity ‐ Field
4/26/2017 26.35 NTU
MW‐13
U = Indicates that the compound was analyzed for but not detected.
BDL = Indicates that the compound was analyzed for but not detected.
I = The reported value is between the laboratory method detection limit and the laboratory practical quatitation limit.V = Indicates the anlyte was detected in both the sample and the associated method blank.
Wednesday, June 21, 2017 Page 5 of 18
Well ID Parameter Sample Date Result Flags Units
MW‐13
Barium, Dissolved
4/27/2017 110 ug/L
Barium, Total
4/27/2017 122 ug/L
Copper, Dissolved
4/27/2017 7.8 ug/L
Copper, Total
4/27/2017 6.5 ug/L
Dissolved Oxygen
4/27/2017 3.1 mg/L
Nickel, Dissolved
4/27/2017 5.1 ug/L
Nickel, Total
4/27/2017 5.2 ug/L
ORP ‐ Field
4/27/2017 139.1 mV
pH ‐ Field
4/27/2017 6.2 Std. Units
Specific Conductivity ‐ Field
4/27/2017 230 umhos/cm
Temperature ‐ Field
4/27/2017 15 deg C
Turbidity ‐ Field
4/27/2017 ‐8.63 NTU
Zinc, Dissolved
4/27/2017 49 ug/L
Zinc, Total
4/27/2017 90.9 ug/L
MW‐13D
Barium, Dissolved
4/27/2017 341 ug/L
Barium, Total
4/27/2017 349 ug/L
Cobalt, Dissolved
4/27/2017 25.9 ug/L
Dissolved Oxygen
U = Indicates that the compound was analyzed for but not detected.
BDL = Indicates that the compound was analyzed for but not detected.
I = The reported value is between the laboratory method detection limit and the laboratory practical quatitation limit.V = Indicates the anlyte was detected in both the sample and the associated method blank.
Wednesday, June 21, 2017 Page 6 of 18
Well ID Parameter Sample Date Result Flags Units
MW‐13D
Dissolved Oxygen
4/27/2017 2.9 mg/L
Nickel, Dissolved
4/27/2017 24.9 ug/L
Nickel, Total
4/27/2017 24.3 ug/L
ORP ‐ Field
4/27/2017 56.8 mV
pH ‐ Field
4/27/2017 6.4 Std. Units
Specific Conductivity ‐ Field
4/27/2017 421 umhos/cm
Temperature ‐ Field
4/27/2017 13.9 deg C
Turbidity ‐ Field
4/27/2017 5.7 NTU
Vanadium, Dissolved
4/27/2017 7.6 ug/L
Vanadium, Total
4/27/2017 6.8 ug/L
Zinc, Total
4/27/2017 13.7 ug/L
MW‐14
Alkalinity, Total
4/26/2017 63200 ug/L
Barium, Dissolved
4/26/2017 46.6 ug/L
Barium, Total
4/26/2017 56.4 ug/L
Chloride
4/26/2017 2720 ug/L
Dissolved Oxygen
4/26/2017 6.03 mg/L
Iron, Total
4/26/2017 1730 ug/L
Manganese, Total
U = Indicates that the compound was analyzed for but not detected.
BDL = Indicates that the compound was analyzed for but not detected.
I = The reported value is between the laboratory method detection limit and the laboratory practical quatitation limit.V = Indicates the anlyte was detected in both the sample and the associated method blank.
Wednesday, June 21, 2017 Page 7 of 18
Well ID Parameter Sample Date Result Flags Units
MW‐14
Manganese, Total
4/26/2017 8.5 ug/L
ORP ‐ Field
4/26/2017 194.3 mV
pH ‐ Field
4/26/2017 6.2 Std. Units
Specific Conductivity ‐ Field
4/26/2017 192 umhos/cm
Sulfate
4/26/2017 24500 ug/L
Temperature ‐ Field
4/26/2017 15.1 deg C
Total Dissolved Solids
4/26/2017 162000 ug/L
Turbidity ‐ Field
4/26/2017 40.15 NTU
Vanadium, Total
4/26/2017 6 ug/L
MW‐14D
Alkalinity, Total
4/26/2017 124000 ug/L
Barium, Total
4/26/2017 5.3 ug/L
Chloride
4/26/2017 2620 ug/L
Dissolved Oxygen
4/26/2017 9.61 mg/L
ORP ‐ Field
4/26/2017 206.7 mV
pH ‐ Field
4/26/2017 6.8 Std. Units
Specific Conductivity ‐ Field
4/26/2017 287 umhos/cm
Sulfate
4/26/2017 20200 ug/L
Temperature ‐ Field
U = Indicates that the compound was analyzed for but not detected.
BDL = Indicates that the compound was analyzed for but not detected.
I = The reported value is between the laboratory method detection limit and the laboratory practical quatitation limit.V = Indicates the anlyte was detected in both the sample and the associated method blank.
Wednesday, June 21, 2017 Page 8 of 18
Well ID Parameter Sample Date Result Flags Units
MW‐14D
Temperature ‐ Field
4/26/2017 15.9 deg C
Total Dissolved Solids
4/26/2017 203000 ug/L
Turbidity ‐ Field
4/26/2017 3.55 NTU
MW‐15D
Alkalinity, Total
4/26/2017 157000 ug/L
Barium, Dissolved
4/26/2017 134 ug/L
Barium, Total
4/26/2017 141 ug/L
Chloride
4/26/2017 8170 ug/L
Dissolved Oxygen
4/26/2017 3.64 mg/L
Iron, Total
4/26/2017 68.7 ug/L
Manganese, Total
4/26/2017 358 ug/L
ORP ‐ Field
4/26/2017 98.8 mV
pH ‐ Field
4/26/2017 6.3 Std. Units
Specific Conductivity ‐ Field
4/26/2017 397 umhos/cm
Sulfate
4/26/2017 37200 ug/L
Temperature ‐ Field
4/26/2017 15.4 deg C
Total Dissolved Solids
4/26/2017 258000 ug/L
Turbidity ‐ Field
4/26/2017 5.83 NTU
MW‐15S
U = Indicates that the compound was analyzed for but not detected.
BDL = Indicates that the compound was analyzed for but not detected.
I = The reported value is between the laboratory method detection limit and the laboratory practical quatitation limit.V = Indicates the anlyte was detected in both the sample and the associated method blank.
Wednesday, June 21, 2017 Page 9 of 18
Well ID Parameter Sample Date Result Flags Units
MW‐15S
Alkalinity, Total
4/26/2017 183000 ug/L
Barium, Dissolved
4/26/2017 188 ug/L
Barium, Total
4/26/2017 229 ug/L
Chloride
4/26/2017 18800 ug/L
Chromium, Total
4/26/2017 5 ug/L
Cobalt, Dissolved
4/26/2017 87.5 ug/L
Dissolved Oxygen
4/26/2017 3.25 mg/L
Iron, Total
4/26/2017 4800 ug/L
Manganese, Total
4/26/2017 10600 ug/L
Nickel, Dissolved
4/26/2017 7.1 ug/L
Nickel, Total
4/26/2017 9.7 ug/L
ORP ‐ Field
4/26/2017 83.1 mV
pH ‐ Field
4/26/2017 6.1 Std. Units
Specific Conductivity ‐ Field
4/26/2017 474 umhos/cm
Sulfate
4/26/2017 31100 ug/L
Temperature ‐ Field
4/26/2017 16.2 deg C
Total Dissolved Solids
4/26/2017 255000 ug/L
Turbidity ‐ Field
4/26/2017 16.02 NTU
U = Indicates that the compound was analyzed for but not detected.
BDL = Indicates that the compound was analyzed for but not detected.
I = The reported value is between the laboratory method detection limit and the laboratory practical quatitation limit.V = Indicates the anlyte was detected in both the sample and the associated method blank.
Wednesday, June 21, 2017 Page 10 of 18
Well ID Parameter Sample Date Result Flags Units
MW‐15S
Vanadium, Dissolved
4/26/2017 14.6 ug/L
Vanadium, Total
4/26/2017 18.5 ug/L
MW‐1D
Alkalinity, Total
4/26/2017 57200 ug/L
Barium, Dissolved
4/26/2017 31.7 ug/L
Barium, Total
4/26/2017 32.1 ug/L
Chloride
4/26/2017 2580 ug/L
Dissolved Oxygen
4/26/2017 7.24 mg/L
Iron, Total
4/26/2017 107 ug/L
Nickel, Total
4/26/2017 5.1 ug/L
ORP ‐ Field
4/26/2017 168.3 mV
pH ‐ Field
4/26/2017 6.5 Std. Units
Specific Conductivity ‐ Field
4/26/2017 179 umhos/cm
Sulfate
4/26/2017 23500 ug/L
Temperature ‐ Field
4/26/2017 14.1 deg C
Total Dissolved Solids
4/26/2017 122000 ug/L
Turbidity ‐ Field
4/26/2017 12.93 NTU
MW‐2
Barium, Dissolved
4/27/2017 56.8 ug/L
U = Indicates that the compound was analyzed for but not detected.
BDL = Indicates that the compound was analyzed for but not detected.
I = The reported value is between the laboratory method detection limit and the laboratory practical quatitation limit.V = Indicates the anlyte was detected in both the sample and the associated method blank.
Wednesday, June 21, 2017 Page 11 of 18
Well ID Parameter Sample Date Result Flags Units
MW‐2
Barium, Total
4/27/2017 66.2 ug/L
Copper, Dissolved
4/27/2017 5.9 ug/L
Dissolved Oxygen
4/27/2017 7.4 mg/L
ORP ‐ Field
4/27/2017 197.3 mV
pH ‐ Field
4/27/2017 6.6 Std. Units
Specific Conductivity ‐ Field
4/27/2017 183 umhos/cm
Temperature ‐ Field
4/27/2017 12 deg C
Turbidity ‐ Field
4/27/2017 37.75 NTU
Zinc, Dissolved
4/27/2017 15 ug/L
MW‐2D
Barium, Dissolved
4/27/2017 95.4 ug/L
Barium, Total
4/27/2017 108 ug/L
Copper, Dissolved
4/27/2017 6.7 ug/L
Dissolved Oxygen
4/27/2017 4.7 mg/L
ORP ‐ Field
4/27/2017 202.6 mV
pH ‐ Field
4/27/2017 6.6 Std. Units
Specific Conductivity ‐ Field
4/27/2017 268 umhos/cm
Temperature ‐ Field
4/27/2017 11.7 deg C
Turbidity ‐ Field
U = Indicates that the compound was analyzed for but not detected.
BDL = Indicates that the compound was analyzed for but not detected.
I = The reported value is between the laboratory method detection limit and the laboratory practical quatitation limit.V = Indicates the anlyte was detected in both the sample and the associated method blank.
Wednesday, June 21, 2017 Page 12 of 18
Well ID Parameter Sample Date Result Flags Units
MW‐2D
Turbidity ‐ Field
4/27/2017 0.6 NTU
Zinc, Dissolved
4/27/2017 16 ug/L
MW‐3R
Barium, Dissolved
4/25/2017 112 ug/L
Barium, Total
4/25/2017 121 ug/L
Dissolved Oxygen
4/25/2017 4.76 mg/L
Nickel, Dissolved
4/25/2017 5.4 ug/L
Nickel, Total
4/25/2017 7.2 ug/L
ORP ‐ Field
4/25/2017 251.4 mV
pH ‐ Field
4/25/2017 6.4 Std. Units
Specific Conductivity ‐ Field
4/25/2017 211 umhos/cm
Temperature ‐ Field
4/25/2017 15.4 deg C
Turbidity ‐ Field
4/25/2017 25.47 NTU
Zinc, Total
4/25/2017 11 ug/L
MW‐4
Barium, Dissolved
4/25/2017 58 ug/L
Barium, Total
4/25/2017 84.8 ug/L
Dissolved Oxygen
4/25/2017 6.45 mg/L
ORP ‐ Field
4/25/2017 257.8 mV
U = Indicates that the compound was analyzed for but not detected.
BDL = Indicates that the compound was analyzed for but not detected.
I = The reported value is between the laboratory method detection limit and the laboratory practical quatitation limit.V = Indicates the anlyte was detected in both the sample and the associated method blank.
Wednesday, June 21, 2017 Page 13 of 18
Well ID Parameter Sample Date Result Flags Units
MW‐4
pH ‐ Field
4/25/2017 6 Std. Units
Specific Conductivity ‐ Field
4/25/2017 152 umhos/cm
Temperature ‐ Field
4/25/2017 15.4 deg C
Turbidity ‐ Field
4/25/2017 32.44 NTU
Vanadium, Total
4/25/2017 8.1 ug/L
MW‐4D
Barium, Dissolved
4/25/2017 26.2 ug/L
Barium, Total
4/25/2017 29.9 ug/L
Dissolved Oxygen
4/25/2017 7.33 mg/L
ORP ‐ Field
4/25/2017 268.6 mV
pH ‐ Field
4/25/2017 6.3 Std. Units
Specific Conductivity ‐ Field
4/25/2017 247 umhos/cm
Temperature ‐ Field
4/25/2017 16.4 deg C
Turbidity ‐ Field
4/25/2017 1.9 NTU
MW‐5
Barium, Dissolved
4/25/2017 106 ug/L
Barium, Total
4/25/2017 124 ug/L
Dissolved Oxygen
4/25/2017 4.63 mg/L
ORP ‐ Field
4/25/2017 253.9 mV
U = Indicates that the compound was analyzed for but not detected.
BDL = Indicates that the compound was analyzed for but not detected.
I = The reported value is between the laboratory method detection limit and the laboratory practical quatitation limit.V = Indicates the anlyte was detected in both the sample and the associated method blank.
Wednesday, June 21, 2017 Page 14 of 18
Well ID Parameter Sample Date Result Flags Units
MW‐5
pH ‐ Field
4/25/2017 6.9 Std. Units
Specific Conductivity ‐ Field
4/25/2017 219 umhos/cm
Temperature ‐ Field
4/25/2017 17.4 deg C
Turbidity ‐ Field
4/25/2017 23.11 NTU
MW‐5D
Barium, Dissolved
4/25/2017 61 ug/L
Barium, Total
4/25/2017 71.8 ug/L
Dissolved Oxygen
4/25/2017 4.8 mg/L
ORP ‐ Field
4/25/2017 252.6 mV
pH ‐ Field
4/25/2017 6.6 Std. Units
Specific Conductivity ‐ Field
4/25/2017 211 umhos/cm
Temperature ‐ Field
4/25/2017 16.2 deg C
Turbidity ‐ Field
4/25/2017 6.06 NTU
Zinc, Total
4/25/2017 11.2 ug/L
MW‐6
Barium, Dissolved
4/25/2017 48.3 ug/L
Barium, Total
4/25/2017 57 ug/L
Dissolved Oxygen
4/25/2017 3.01 mg/L
ORP ‐ Field
4/25/2017 254.9 mV
U = Indicates that the compound was analyzed for but not detected.
BDL = Indicates that the compound was analyzed for but not detected.
I = The reported value is between the laboratory method detection limit and the laboratory practical quatitation limit.V = Indicates the anlyte was detected in both the sample and the associated method blank.
Wednesday, June 21, 2017 Page 15 of 18
Well ID Parameter Sample Date Result Flags Units
MW‐6
pH ‐ Field
4/25/2017 6.3 Std. Units
Specific Conductivity ‐ Field
4/25/2017 143 umhos/cm
Temperature ‐ Field
4/25/2017 16.6 deg C
Turbidity ‐ Field
4/25/2017 10.16 NTU
Zinc, Dissolved
4/25/2017 13.8 ug/L
MW‐7
Barium, Dissolved
4/25/2017 122 ug/L
Barium, Total
4/25/2017 139 ug/L
Dissolved Oxygen
4/25/2017 2.06 mg/L
Nickel, Dissolved
4/25/2017 6.4 ug/L
Nickel, Total
4/25/2017 7.4 ug/L
ORP ‐ Field
4/25/2017 110.7 mV
pH ‐ Field
4/25/2017 6.2 Std. Units
Specific Conductivity ‐ Field
4/25/2017 626 umhos/cm
Temperature ‐ Field
4/25/2017 16.4 deg C
Turbidity ‐ Field
4/25/2017 6.49 NTU
Zinc, Dissolved
4/25/2017 17 ug/L
MW‐8
Barium, Dissolved
4/27/2017 124 ug/L
U = Indicates that the compound was analyzed for but not detected.
BDL = Indicates that the compound was analyzed for but not detected.
I = The reported value is between the laboratory method detection limit and the laboratory practical quatitation limit.V = Indicates the anlyte was detected in both the sample and the associated method blank.
Wednesday, June 21, 2017 Page 16 of 18
Well ID Parameter Sample Date Result Flags Units
MW‐8
Barium, Total
4/27/2017 130 ug/L
Dissolved Oxygen
4/27/2017 4.3 mg/L
ORP ‐ Field
4/27/2017 288 mV
pH ‐ Field
4/27/2017 6.7 Std. Units
Specific Conductivity ‐ Field
4/27/2017 360 umhos/cm
Temperature ‐ Field
4/27/2017 15.2 deg C
Turbidity ‐ Field
4/27/2017 8.11 NTU
Zinc, Dissolved
4/27/2017 17.1 ug/L
Zinc, Total
4/27/2017 11.6 ug/L
MW‐8D
Barium, Dissolved
4/27/2017 151 ug/L
Barium, Total
4/27/2017 161 ug/L
Copper, Total
4/27/2017 9.5 ug/L
Dissolved Oxygen
4/27/2017 2.2 mg/L
ORP ‐ Field
4/27/2017 266 mV
pH ‐ Field
4/27/2017 6.6 Std. Units
Specific Conductivity ‐ Field
4/27/2017 408 umhos/cm
Temperature ‐ Field
4/27/2017 15.5 deg C
Turbidity ‐ Field
U = Indicates that the compound was analyzed for but not detected.
BDL = Indicates that the compound was analyzed for but not detected.
I = The reported value is between the laboratory method detection limit and the laboratory practical quatitation limit.V = Indicates the anlyte was detected in both the sample and the associated method blank.
Wednesday, June 21, 2017 Page 17 of 18
Well ID Parameter Sample Date Result Flags Units
MW‐8D
Turbidity ‐ Field
4/27/2017 3.32 NTU
Zinc, Dissolved
4/27/2017 13.9 ug/L
Zinc, Total
4/27/2017 27.5 ug/L
U = Indicates that the compound was analyzed for but not detected.
BDL = Indicates that the compound was analyzed for but not detected.
I = The reported value is between the laboratory method detection limit and the laboratory practical quatitation limit.V = Indicates the anlyte was detected in both the sample and the associated method blank.
Wednesday, June 21, 2017 Page 18 of 18
Surface Water Detection Summary Report
Buncombe County New Facility
From:01/01/2017 To:06/06/2017
Well ID Parameter Sample Date Result Flags Units
SW‐1
Barium, Total
4/21/2017 128 ug/L
Copper, Total
4/21/2017 8.1 ug/L
pH ‐ Field
4/21/2017 6.7 Std. Units
Specific Conductivity ‐ Field
4/21/2017 266 umhos/cm
Temperature ‐ Field
4/21/2017 19.9 deg C
Turbidity ‐ Field
4/21/2017 11.14 NTU
SW‐2
Barium, Total
4/21/2017 65.4 ug/L
pH ‐ Field
4/21/2017 7.5 Std. Units
Specific Conductivity ‐ Field
4/21/2017 156 umhos/cm
Temperature ‐ Field
4/21/2017 18.2 deg C
Turbidity ‐ Field
4/21/2017 20.68 NTU
SW‐3
Barium, Total
4/21/2017 42.9 ug/L
pH ‐ Field
4/21/2017 7.1 Std. Units
Specific Conductivity ‐ Field
4/21/2017 256 umhos/cm
Temperature ‐ Field
4/21/2017 24 deg C
U = Indicates that the compound was analyzed for but not detected.
BDL = Indicates that the compound was analyzed for but not detected.
I = The reported value is between the laboratory method detection limit and the laboratory practical quatitation limit.V = Indicates the anlyte was detected in both the sample and the associated method blank.
Monday, June 26, 2017 Page 1 of 3
Well ID Parameter Sample Date Result Flags Units
SW‐3
Turbidity ‐ Field
4/21/2017 5.69 NTU
SW‐4
Barium, Total
4/21/2017 134 ug/L
pH ‐ Field
4/21/2017 7.7 Std. Units
Specific Conductivity ‐ Field
4/21/2017 348 umhos/cm
Temperature ‐ Field
4/21/2017 19 deg C
Turbidity ‐ Field
4/21/2017 42.86 NTU
SW‐5
Barium, Total
4/21/2017 20.6 ug/L
Nickel, Total
4/21/2017 6.8 ug/L
pH ‐ Field
4/21/2017 8.2 Std. Units
Specific Conductivity ‐ Field
4/21/2017 636 umhos/cm
Temperature ‐ Field
4/21/2017 17.2 deg C
Turbidity ‐ Field
4/21/2017 13.59 NTU
Zinc, Total
4/21/2017 12.4 ug/L
SW‐6
Barium, Total
4/21/2017 98.8 ug/L
pH ‐ Field
4/21/2017 7.3 Std. Units
Specific Conductivity ‐ Field
4/21/2017 268 umhos/cm
Temperature ‐ Field
U = Indicates that the compound was analyzed for but not detected.
BDL = Indicates that the compound was analyzed for but not detected.
I = The reported value is between the laboratory method detection limit and the laboratory practical quatitation limit.V = Indicates the anlyte was detected in both the sample and the associated method blank.
Monday, June 26, 2017 Page 2 of 3
Well ID Parameter Sample Date Result Flags Units
SW‐6
Temperature ‐ Field
4/21/2017 17.7 deg C
Turbidity ‐ Field
4/21/2017 10.94 NTU
SW‐7
Barium, Total
4/21/2017 213 ug/L
Nickel, Total
4/21/2017 12.8 ug/L
pH ‐ Field
4/21/2017 7 Std. Units
Specific Conductivity ‐ Field
4/21/2017 468 umhos/cm
Temperature ‐ Field
4/21/2017 19.9 deg C
Turbidity ‐ Field
4/21/2017 20.53 NTU
Zinc, Total
4/21/2017 17.7 ug/L
U = Indicates that the compound was analyzed for but not detected.
BDL = Indicates that the compound was analyzed for but not detected.
I = The reported value is between the laboratory method detection limit and the laboratory practical quatitation limit.V = Indicates the anlyte was detected in both the sample and the associated method blank.
Monday, June 26, 2017 Page 3 of 3
Leachate Detection Summary Report
Buncombe County New Facility
From:01/01/2017 To:06/06/2017
Well ID Parameter Sample Date Result Flags Units
LD‐1
1,1‐Dichloroethane
4/24/2017 1.7 ug/L
Barium, Total
4/24/2017 60.9 ug/L
Dissolved Oxygen
4/24/2017 2.29 mg/L
Nickel, Total
4/24/2017 41.7 ug/L
ORP ‐ Field
4/24/2017 59.1 mV
pH ‐ Field
4/24/2017 5.7 Std. Units
Specific Conductivity ‐ Field
4/24/2017 274 umhos/cm
Temperature ‐ Field
4/24/2017 13.5 deg C
Turbidity ‐ Field
4/24/2017 0.77 NTU
Vanadium, Total
4/24/2017 6.4 ug/L
LD‐2
1,1‐Dichloroethane
4/24/2017 2.9 ug/L
Barium, Total
4/24/2017 153 ug/L
Dissolved Oxygen
4/24/2017 2.48 mg/L
Nickel, Total
4/24/2017 10.4 ug/L
ORP ‐ Field
4/24/2017 9.4 mV
pH ‐ Field
U = Indicates that the compound was analyzed for but not detected.
BDL = Indicates that the compound was analyzed for but not detected.
I = The reported value is between the laboratory method detection limit and the laboratory practical quatitation limit.V = Indicates the anlyte was detected in both the sample and the associated method blank.
Wednesday, June 21, 2017 Page 1 of 6
Well ID Parameter Sample Date Result Flags Units
LD‐2
pH ‐ Field
4/24/2017 5.8 Std. Units
Specific Conductivity ‐ Field
4/24/2017 374 umhos/cm
Temperature ‐ Field
4/24/2017 14.1 deg C
Turbidity ‐ Field
4/24/2017 1.6 NTU
Vanadium, Total
4/24/2017 10.7 ug/L
LD‐3
Barium, Total
4/24/2017 215 ug/L
Chromium, Total
4/24/2017 9.9 ug/L
Dissolved Oxygen
4/24/2017 3.46 mg/L
Nickel, Total
4/24/2017 7.7 ug/L
ORP ‐ Field
4/24/2017 1.7 mV
pH ‐ Field
4/24/2017 6.4 Std. Units
Specific Conductivity ‐ Field
4/24/2017 542 umhos/cm
Temperature ‐ Field
4/24/2017 15.8 deg C
Turbidity ‐ Field
4/24/2017 34.77 NTU
Vanadium, Total
4/24/2017 6.7 ug/L
LD‐4
Barium, Total
4/24/2017 865 ug/L
Benzene
4/24/2017 1.7 ug/L
U = Indicates that the compound was analyzed for but not detected.
BDL = Indicates that the compound was analyzed for but not detected.
I = The reported value is between the laboratory method detection limit and the laboratory practical quatitation limit.V = Indicates the anlyte was detected in both the sample and the associated method blank.
Wednesday, June 21, 2017 Page 2 of 6
Well ID Parameter Sample Date Result Flags Units
LD‐4
Chromium, Total
4/24/2017 134 ug/L
Copper, Total
4/24/2017 86.6 ug/L
Dissolved Oxygen
4/24/2017 2.31 mg/L
Nickel, Total
4/24/2017 94 ug/L
ORP ‐ Field
4/24/2017 17.9 mV
pH ‐ Field
4/24/2017 5.5 Std. Units
Specific Conductivity ‐ Field
4/24/2017 648 umhos/cm
Temperature ‐ Field
4/24/2017 16.6 deg C
Turbidity ‐ Field
4/24/2017 8.12 NTU
Vanadium, Total
4/24/2017 9.7 ug/L
Zinc, Total
4/24/2017 27.5 ug/L
LD‐5
Barium, Total
4/24/2017 109 ug/L
Dissolved Oxygen
4/24/2017 5.48 mg/L
Nickel, Total
4/24/2017 13.5 ug/L
ORP ‐ Field
4/24/2017 57.3 mV
pH ‐ Field
4/24/2017 6.6 Std. Units
Specific Conductivity ‐ Field
4/24/2017 688 umhos/cm
Temperature ‐ Field
U = Indicates that the compound was analyzed for but not detected.
BDL = Indicates that the compound was analyzed for but not detected.
I = The reported value is between the laboratory method detection limit and the laboratory practical quatitation limit.V = Indicates the anlyte was detected in both the sample and the associated method blank.
Wednesday, June 21, 2017 Page 3 of 6
Well ID Parameter Sample Date Result Flags Units
LD‐5
Temperature ‐ Field
4/24/2017 16.7 deg C
Turbidity ‐ Field
4/24/2017 22.53 NTU
Vanadium, Total
4/24/2017 11.6 ug/L
LD‐6
Barium, Total
4/24/2017 398 ug/L
Dissolved Oxygen
4/24/2017 3 mg/L
ORP ‐ Field
4/24/2017 195 mV
pH ‐ Field
4/24/2017 6.2 Std. Units
Specific Conductivity ‐ Field
4/24/2017 596 umhos/cm
Temperature ‐ Field
4/24/2017 17.9 deg C
Turbidity ‐ Field
4/24/2017 44.98 NTU
Vanadium, Total
4/24/2017 16.8 ug/L
LEACHATE
1,4‐Dichlorobenzene
4/24/2017 2.5 ug/L
Acetone
4/24/2017 30.3 ug/L
Antimony, Total
4/24/2017 7.2 ug/L
Barium, Total
4/24/2017 239 ug/L
Benzene
4/24/2017 1.9 ug/L
Chromium, Total
4/24/2017 24.7 ug/L
U = Indicates that the compound was analyzed for but not detected.
BDL = Indicates that the compound was analyzed for but not detected.
I = The reported value is between the laboratory method detection limit and the laboratory practical quatitation limit.V = Indicates the anlyte was detected in both the sample and the associated method blank.
Wednesday, June 21, 2017 Page 4 of 6
Well ID Parameter Sample Date Result Flags Units
LEACHATE
Ethylbenzene
4/24/2017 3.5 ug/L
Nickel, Total
4/24/2017 57.7 ug/L
ORP ‐ Field
4/24/2017 124 mV
o‐Xylene
4/24/2017 1.6 ug/L
pH ‐ Field
4/24/2017 7.8 Std. Units
Specific Conductivity ‐ Field
4/24/2017 4948 umhos/cm
Temperature ‐ Field
4/24/2017 17.1 deg C
Toluene
4/24/2017 1.5 ug/L
Turbidity ‐ Field
4/24/2017 116.1 NTU
Vanadium, Total
4/24/2017 17.1 ug/L
Xylene (Total)
4/24/2017 6.9 ug/L
Zinc, Total
4/24/2017 23.8 ug/L
LEACHATE LD
Arsenic, Total
4/24/2017 15.7 ug/L
Barium, Total
4/24/2017 14.4 ug/L
Copper, Total
4/24/2017 22.5 ug/L
Dissolved Oxygen
4/24/2017 6.27 mg/L
Nickel, Total
4/24/2017 525 ug/L
ORP ‐ Field
U = Indicates that the compound was analyzed for but not detected.
BDL = Indicates that the compound was analyzed for but not detected.
I = The reported value is between the laboratory method detection limit and the laboratory practical quatitation limit.V = Indicates the anlyte was detected in both the sample and the associated method blank.
Wednesday, June 21, 2017 Page 5 of 6
Well ID Parameter Sample Date Result Flags Units
LEACHATE LD
ORP ‐ Field
4/24/2017 168.8 mV
pH ‐ Field
4/24/2017 5.4 Std. Units
Specific Conductivity ‐ Field
4/24/2017 656 umhos/cm
Temperature ‐ Field
4/24/2017 14.1 deg C
Turbidity ‐ Field
4/24/2017 0.14 NTU
Zinc, Total
4/24/2017 225 ug/L
U = Indicates that the compound was analyzed for but not detected.
BDL = Indicates that the compound was analyzed for but not detected.
I = The reported value is between the laboratory method detection limit and the laboratory practical quatitation limit.V = Indicates the anlyte was detected in both the sample and the associated method blank.
Wednesday, June 21, 2017 Page 6 of 6
Buncombe County New Landfill Spring 2017 Semi-Annual Sampling
ATTACHMENT E
EXCEEDANCE TABLES
Groundwater MCL Exceedance Summary Report
Buncombe County New Facility
From:01/01/2017 To:06/06/2017
Well ID Parameter Sample Date Result Flags UnitsMCL
MW‐1
Iron, Total 300
4/26/2017 2610 ug/L
Vanadium, Total 0.3
4/26/2017 6.8 ug/L
MW‐12
Iron, Total 300
4/26/2017 1120 ug/L
MW‐12D
Iron, Total 300
4/26/2017 894 ug/L
MW‐13D
Vanadium, Total 0.3
4/27/2017 6.8 ug/L
MW‐14
Iron, Total 300
4/26/2017 1730 ug/L
Vanadium, Total 0.3
4/26/2017 6 ug/L
MW‐15D
Manganese, Total 50
4/26/2017 358 ug/L
MW‐15S
Iron, Total 300
4/26/2017 4800 ug/L
Manganese, Total 50
4/26/2017 10600 ug/L
Vanadium, Total 0.3
4/26/2017 18.5 ug/L
MW‐4
Vanadium, Total 0.3
4/25/2017 8.1 ug/L
U = Indicates that the compound was analyzed for but not detected.
BDL = Indicates that the compound was analyzed for but not detected.
I = The reported value is between the laboratory method detection limit and the laboratory practical quatitation limit.V = Indicates the anlyte was detected in both the sample and the associated method blank.
Wednesday, June 21, 2017 Page 1 of 1