Loading...
HomeMy WebLinkAboutSDTF8002_INSP_20161020 (2)FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section Page 1 of 2 UNIT TYPE: Lined MSWLF LCID YW Transfer Compost SLAS COUNTY: Rowan Closed MSWLF HHW White goods Incin T&P FIRM PERMIT NO.: SDTF-80-02 CDLF Tire T&P / Collection Tire Monofill Industrial Landfill DEMO SDTF X FILE TYPE: COMPLIANCE Date of Site Inspection: 6/14/2016 Date of Last Inspection: 8/25/2015 FACILITY NAME AND ADDRESS: Myers Septic Tank Co. Briggs Road Salisbury, North Carolina 28147 GPS COORDINATES: N: 36.67591° W: 80.58016° FACILITY CONTACT NAME AND PHONE NUMBER: Name: Benny Myers, President Todd Myers, Vice-President Telephone: (704) 633-3962 Email address: myersseptictank@att.net FACILITY CONTACT ADDRESS: 1882 Briggs Road Salisbury, North Carolina 28147 PARTICIPANTS: Troy Harrison, Composting & Land Application Branch Benny Myers, Myers Septic Tank Co. STATUS OF PERMIT: Active Issued: 12/16/2015 Expires: 8/1/2020 PURPOSE OF SITE VISIT: Routine Inspection STATUS OF PAST NOTED VIOLATIONS: Past observed violations have been corrected OBSERVED VIOLATIONS: N/A The item(s) listed above were observed by Section staff and require action on behalf of the facility in order to come into or maintain compliance with the Statutes, Rules, and/or other regulatory requirements applicable to this facility. Be advised that pursuant to N.C.G.S. 130A-22, an administrative penalty of up to $15,000 per day may be assessed for each violation of the Solid Waste Laws, Regulations, Conditions of a Permit, or Order under Article 9 of Chapter 130A of the N.C. General Statutes. Further, the facility and/or all responsible parties may also be subject to enforcement actions including penalties, injunction from operation of a solid waste management facility or a solid waste collection service and any such further relief as may be necessary to achieve compliance with the North Carolina Solid Waste Management Act and Rules. FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section Page 2 of 2 ADDITIONAL COMMENTS 1. The permitted Septage Detention and Treatment facility consist of one 30,000 gallon, one 5,000 gallon and three 20,000 gallon above ground metal tanks for storage and treatment of domestic septage, portable toilet waste, grease trap pumping, and commercial/industrial septage. 2. Appropriate signage was in place along access roads. 3. Vegetative growth was effectively controlled in the areas in front of the tanks. 4. All tanks at the facility appeared to be structurally sound. There were several areas that have the potential for future leaks that will need to be repaired. 5. Vectors were not present at the time of inspection nor were objectionable odors observed. 6. Approved setbacks and buffers for the septage detention and treatment facility storage tanks appear to have been met. Please contact me if you have any questions or concerns regarding this inspection report. _______________________________________ Phone: 828-296-4701 Troy Harrison Environmental Senior Specialist Regional Representative Sent on: November 4, 2016 X Email Hand delivery US Mail Certified No. [ _] Copies: Corinne Law, Composting & Land Application Branch Connie Wylie, Composting & Land Application Branch