Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2906_DavidsonCoCDLF_Comment_CQAforLFClosure_DIN27813_20170522
1 Chao, Ming-tai From:Chao, Ming-tai Sent:Monday, May 22, 2017 11:26 AM To:'Pieter Scheer' Cc:Buck, Rex; Sink, Steven; Heim, Susan A Subject:Comments on Davidson County C&D Landfill (Permit No. 2906-CDLF) Closure - CQA Report Hi Pieter: The Solid Waste Section completes a review of the certified CQA Report (DIN 27735) of the above-referenced landfill and has several comments (DIN 27813) stated below: DIN 27813 1. (Section 5.2) a. The closed area for the C&DLF is approximately 7.6 acres as reported in Section 1.0. This section records the earthen material of 21,200 cubic yards (CY) was used to construct the two-feet vegetative soil layer; back-calculation of the extent of the closed area, based on the data from the CQA Report, shows the closed area is approximately 6.57 acres. If the closed area is 7.6 acres, should the soil volume for the 2-foot vegetative soil layer be approximately 24,523 cy? Please clarify. b. If the amount of soil of 21,200 CY is correct, the number of testing of Atterberg Limits (ASTM D 4318) shall be five (5) according to the testing frequency in Table 9.1 of the approved CQA Plan (DIN 26957). Appendix E -Earth Work CQA Data only provide four (4) Atterberg Limits test results. Please provide the missing data. 2. (Section 7.3) The quantity of LLDPE received for the project is 3 roll/1 lot and 51,060 square feet (SF) according to the Agru shipping document. The stated 51,750 SF in this section is likely a typo. Please verify. 3. (Appendix G) a. According the approved Technical Specification Section 02778, Paragraph C.2.b., please provide the copy of manufacturer’s and workmanship warranties to the CQA report. b. According the approved Technical Specification Section 02778, Paragraph D.3.b. & Section 5.3.2 of the CQA Plan, please provide the copy of the LLDPE prepared subgrade / surface of the intermediate soil layer acceptance form to the CQA report. c. According to Agru shipping paper (Doc# 35927) the resin lot # is CGK810470 for the 3 rolls of 40- mil LLDPE used in the project, but the Oven-aging test and UV-aging test done by Chevron Philips are on material with different Lot # or Roll #. Please clarify. d. The seam number P10-12 has been repeated in the Non-Destructive Testing Form; it is likely that one of them is a typo of P11-12, which is not available in the form. 2 Please contact me if you have any questions on the above-mentioned comments. Have a wonderful day. Ming Chao Ming-Tai Chao, P.E. Environmental Engineer Permitting Branch, Solid Waste Section NCDEQ, Division of Waste Management (Mailing Address) 1646 Mail Service Center Raleigh, NC 27699-1646 (Street Address) Green Square, 217 West Jones Street Raleigh, NC 27603 Tel. 919-707-8251 ming.chao@ncdenr.gov http://portal.ncdenr.org/web/wm/sw E-mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties. From: Pieter Scheer [mailto:pieter@smithgardnerinc.com] Sent: Tuesday, May 16, 2017 10:43 AM To: Chao, Ming-tai <ming.chao@ncdenr.gov> Cc: Buck, Rex <Rex.Buck@davidsoncountync.gov>; Sink, Steven <steven.sink@davidsoncountync.gov>; Scheer, Pieter <pieter@smithgardnerinc.com> Subject: Davidson County C&D Landfill (Permit No. 2906-CDLF) Closure - CQA Report Ming: Please use the links below to access a transmittal letter and the CQA report for the closure of the C&D landfill unit. Just let me know if you have any difficulties accessing the files. Thanks. Pieter Pieter K. Scheer, P.E. Vice President, Senior Engineer SMITH + GARDNER 14 N. Boylan Avenue Raleigh, NC 27603 P (919) 828.0577 F (919) 828.3899 C (919) 815.9377 www.smithgardnerinc.com 3 From: Pieter Scheer [mailto:notify@egnyte.com] Sent: Tuesday, May 16, 2017 10:38 AM To: pieter@smithgardnerinc.com Cc: pieter@smithgardnerinc.com Subject: Pieter Scheer has shared files with you I've shared files with you 01 M Chao Letter 2017-05-16 (DC C&DLF Closure).pdf DC C&DLF Closure CQA Report 2017-05.pdf Your access expires on 06/16/2017 © 2017 Egnyte, Inc. - Discover New Features